Yunus, Mahira
2012-11-01
To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.
Beaulieu, C F; Jeffrey, R B; Karadi, C; Paik, D S; Napel, S
1999-07-01
To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.
CT biliary cystoscopy of gallbladder polyps
Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu
2004-01-01
AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726
WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, W; Rao, A; Wendt, R
Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded asmore » it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.« less
[Virtual otoscopy--technique, indications and initial experiences with multislice spiral CT].
Klingebiel, R; Bauknecht, H C; Lehmann, R; Rogalla, P; Werbs, M; Behrbohm, H; Kaschke, O
2000-11-01
We report the standardized postprocessing of high-resolution CT data acquired by incremental CT and multi-slice CT in patients with suspected middle ear disorders to generate three-dimensional endoluminal views known as virtual otoscopy. Subsequent to the definition of a postprocessing protocol, standardized endoluminal views of the middle ear were generated according to their otological relevance. The HRCT data sets of 26 ENT patients were transferred to a workstation and postprocessed to 52 virtual otoscopies. Generation of predefined endoluminal views from the HRCT data sets was possible in all patients. Virtual endoscopic views added meaningful information to the primary cross-sectional data in patients suffering from ossicular pathology, having contraindications for invasive tympanic endoscopy or being assessed for surgery of the tympanic cavity. Multi slice CT improved the visualization of subtle anatomic details such as the stapes suprastructure and reduced the scanning time. Virtual endoscopy allows for the non invasive endoluminal visualization of various tympanic lesions. Use of the multi-slice CT technique reduces the scanning time and improves image quality in terms of detail resolution.
[Virtual CT-pneumocystoscopy: indications, advantages and limitations. Our experience].
Regine, Giovanni; Atzori, Maurizio; Buffa, Vitaliano; Miele, Vittorio; Ialongo, Pasquale; Adami, Loredana
2003-09-01
The use of CT volume-rendering techniques allows the evaluation of visceral organs without the need for endoscopy. Conventional endoscopic evaluation of the bladder is limited by the invasiveness of the technique and the difficulty exploring the entire bladder. Virtual evaluation of the bladder by three-dimensional CT reconstruction offers potential advantages and can be used in place of endoscopy. This study investigates the sensitivity of virtual CT in assessing lesion of the bladder wall to compare it with that of conventional endoscopy, and outlines the indications, advantages and disadvantages of virtual CT-pneumocystography. Between September 2001 and May 2002, 21 patients with haematuria and positive cystoscopic findings were studied. After an initial assessment by ultrasound, the patients underwent pelvic CT as a single volumetric scan after preliminary air distension of the bladder by means of 12 F Foley catheter. The images were processed on an independent workstation (Advantage 3.0 GE) running dedicated software for endoluminal navigation. The lesions detected by endoscopy were classified as sessile or pedunculated, and according to size (more or less than 5 mm). Finally, the results obtained at virtual cystoscopy were evaluated by two radiologists blinded to the conventional cystoscopy results. Thirty lesions (24 pedunculated, 6 sessile) were detected at conventional cystoscopy in 16 patients (multiple polyposis in 3 cases). Virtual cystoscopy identified 23 lesions (19 pedunculated and 4 sessile). The undetected lesions were pedunculated <5 mm (5 cases) and sessile (2 cases). One correctly identified pedunculated lesion was associated with a bladder stone. Good quality virtual images were obtained in all of the patients. In only one patient with multiple polyposis the quality of the virtual endoscopic evaluation was limited by the patient's intolerance to bladder distension, although identification of the lesions was not compromised. The overall sensitivity was 77%; this was higher for pedunculated lesions (79%) than for sessile lesions (50%). The virtual technique is less invasive and tends to be associated with fewer complications than is conventional cystoscopy. It also demonstrated a good sensitivity for evaluating pedunculated lesions, allowing evaluation of the bladder base and anterior wall, sites that are commonly poorly accessible at conventional cystoscopy. Further advantages of the virtual technique include the possibility of accurately measuring the extent of the lesion and obtaining virtual images even in patients with severe urethral obstruction and active bleeding. The limitations include the inability to obtain tissue for histologic examination or to perform endoscopic resection of pedunculated lesions. The technique is less sensitive than conventional cystoscopy in the detection of sessile lesions or very small polyps (<5 mm). Furthermore, diffuse wall thickening reduces bladder distension thereby preventing optimal evaluation. The most valuable indication appears to be the follow-up of treated wall lesions. Virtual CT-pneumocystoscopy can replace conventional cystoscopy in cases with pedunculated lesions when there is no need for biopsy, when the lesions are located at the bladder base or when cystoscopic instrumentation cannot be introduced into the bladder due to stenosis. Virtual pneumocystoscopy can also be used in the follow-up of treated polypoid lesions in association with pelvic CT-angiography.
Liu, Sheena Xin; Gutiérrez, Luis F; Stanton, Doug
2011-05-01
Electromagnetic (EM)-guided endoscopy has demonstrated its value in minimally invasive interventions. Accuracy evaluation of the system is of paramount importance to clinical applications. Previously, a number of researchers have reported the results of calibrating the EM-guided endoscope; however, the accumulated errors of an integrated system, which ultimately reflect intra-operative performance, have not been characterized. To fill this vacancy, we propose a novel system to perform this evaluation and use a 3D metric to reflect the intra-operative procedural accuracy. This paper first presents a portable design and a method for calibration of an electromagnetic (EM)-tracked endoscopy system. An evaluation scheme is then described that uses the calibration results and EM-CT registration to enable real-time data fusion between CT and endoscopic video images. We present quantitative evaluation results for estimating the accuracy of this system using eight internal fiducials as the targets on an anatomical phantom: the error is obtained by comparing the positions of these targets in the CT space, EM space and endoscopy image space. To obtain 3D error estimation, the 3D locations of the targets in the endoscopy image space are reconstructed from stereo views of the EM-tracked monocular endoscope. Thus, the accumulated errors are evaluated in a controlled environment, where the ground truth information is present and systematic performance (including the calibration error) can be assessed. We obtain the mean in-plane error to be on the order of 2 pixels. To evaluate the data integration performance for virtual navigation, target video-CT registration error (TRE) is measured as the 3D Euclidean distance between the 3D-reconstructed targets of endoscopy video images and the targets identified in CT. The 3D error (TRE) encapsulates EM-CT registration error, EM-tracking error, fiducial localization error, and optical-EM calibration error. We present in this paper our calibration method and a virtual navigation evaluation system for quantifying the overall errors of the intra-operative data integration. We believe this phantom not only offers us good insights to understand the systematic errors encountered in all phases of an EM-tracked endoscopy procedure but also can provide quality control of laboratory experiments for endoscopic procedures before the experiments are transferred from the laboratory to human subjects.
Virtual gastrointestinal colonoscopy in combination with large bowel endoscopy: Clinical application
He, Qing; Rao, Ting; Guan, Yong-Song
2014-01-01
Although colorectal cancer (CRC) has no longer been the leading cancer killer worldwide for years with the exponential development in computed tomography (CT) or magnetic resonance imaging, and positron emission tomography/CT as well as virtual colonoscopy for early detection, the CRC related mortality is still high. The objective of CRC screening is to reduce the burden of CRC and thereby the morbidity and mortality rates of the disease. It is believed that this goal can be achieved by regularly screening the average-risk population, enabling the detection of cancer at early, curable stages, and polyps before they become cancerous. Large-scale screening with multimodality imaging approaches plays an important role in reaching that goal to detect polyps, Crohn’s disease, ulcerative colitis and CRC in early stage. This article reviews kinds of presentative imaging procedures for various screening options and updates detecting, staging and re-staging of CRC patients for determining the optimal therapeutic method and forecasting the risk of CRC recurrence and the overall prognosis. The combination use of virtual colonoscopy and conventional endoscopy, advantages and limitations of these modalities are also discussed. PMID:25320519
Application of MR virtual endoscopy in children with hydrocephalus.
Zhao, Cailei; Yang, Jian; Gan, Yungen; Liu, Jiangang; Tan, Zhen; Liang, Guohua; Meng, Xianlei; Sun, Longwei; Cao, Weiguo
2015-12-01
To evaluate the performance of MR virtual endoscopy (MRVE) in children with hydrocephalus. Clinical and imaging data were collected from 15 pediatric patients with hydrocephalus and 15 normal control children. All hydrocephalus patients were confirmed by ventriculoscopy or CT imaging. The cranial 3D-T1 weighted imaging data from fast spoiled gradient echo scan (FSPGR) were transported to working station. VE images of cerebral ventricular cavity were constructed with Navigator software. Cerebral ventricular MRVE can achieve similar results as ventriculoscopy in demonstrating the morphology of ventricular wall or intracavity lesion. In addition, MRVE can observe the lesion from distal end of obstruction, as well as other areas that are inaccessible to ventriculoscopy. MRVE can also reveal the pathological change of ventricular inner wall surface, and help determine patency of the cerebral aqueduct and fourth ventricle outlet. MR virtual endoscopy provides a non-invasive diagnostic modality that can be used as a supplemental approach to ventriculoscopy. However, its sensitivity and specificity need to be determined in the large study. Copyright © 2015 Elsevier Inc. All rights reserved.
Li, Gang; Ma, Xiangxing; Wang, Qing; Yu, Dexin
2016-01-01
Aims Conventional computed tomography (CT) approaches provides limited visualization of the entire endoluminal changes of aortic dissection (AD), which is essential for its treatment. As an important supplement, three-dimensional CT virtual intravascular endoscopy (VIE) can show relevant details. This study aims to determine the value of VIE in displaying the entry tear and intimal flap of AD. Methods and Results Among 127 consecutive symptomatic patients with suspected AD who underwent CT angiography (CTA), 84 subjects were confirmed to have AD and were included in the study. Conventional CT and VIE images were observed and evaluated. From the 92 entry tears revealed via conventional CT, 88 (95.7%) tears appeared on VIE with round (n = 26), slit-shaped (n = 9), or irregular (n = 53) shapes, whereas the intimal flaps were sheetlike (n = 34), tubular (n = 34), wavelike (n = 13), or irregular (n = 7) in shape. The VIE also showed the spatial relationship between the torn flap and adjacent structures. Among 58 entry tears with multiple-line type flap shown on conventional CT, 41 (70.7%) appeared with an irregular shape on VIE, whereas among 30 tears with single-line type flap, 17 (56.7%) appeared as round or slit-shaped on VIE. These results demonstrated a significant difference (P < 0.05). The poor display of tears on VIE was related to the low CT attenuation values in lumen or in neighboring artifacts (P < 0.01). Conclusion CT VIE presents the complete configurations and details of the intimal tears and flaps of AD better than conventional CT approaches. Accordingly, it should be recommended as a necessary assessment tool for endovascular therapy and as part of strategy planning in pre-surgical patients. PMID:27760170
[Virtual endoscopy with a volumetric reconstruction technic: the technical aspects].
Pavone, P; Laghi, A; Panebianco, V; Catalano, C; Giura, R; Passariello, R
1998-06-01
We analyze the peculiar technical features of virtual endoscopy obtained with volume rendering. Our preliminary experience is based on virtual endoscopy images from volumetric data acquired with spiral CT (Siemens, Somatom Plus 4) using acquisition protocols standardized for different anatomic areas. Images are reformatted at the CT console, to obtain 1 mm thick contiguous slices, and transferred in DICOM format to an O2 workstation (Silicon Graphics, Mountain View CA, USA) with processor speed of 180 Mhz, 256 Mbyte RAM memory and 4.1 Gbyte hard disk. The software is Vitrea 1.0 (Vital Images, Fairfield, Iowa), running on a Unix platform. Image output is obtained through the Ethernet network to a Macintosh computer and a thermic printer (Kodak 8600 XLS). Diagnostic quality images were obtained in all the cases. Fly-through in the airways allowed correct evaluation of the main bronchi and of the origin of segmentary bronchi. In the vascular district, both carotid strictures and abdominal aortic aneurysms were depicted, with the same accuracy as with conventional reconstruction techniques. In the colon studies, polypoid lesions were correctly depicted in all the cases, with good correlation with endoscopic and double-contrast barium enema findings. In a case of lipoma of the ascending colon, virtual endoscopy allowed to study the colon both cranially and caudally to the lesion. The simultaneous evaluation of axial CT images permitted to characterize the lesion correctly on the basis of its density values. The peculiar feature of volume rendering is the use of the whole information inside the imaging volume to reconstruct three-dimensional images; no threshold values are used and no data are lost as opposite to conventional image reconstruction techniques. The different anatomic structures are visualized modifying the reciprocal opacities, showing the structures of no interest as translucent. The modulation of different opacities is obtained modifying the shape of the opacity curve, either using pre-set curves or in a completely independent way. Other technical features of volume rendering are the perspective evaluation of the objects, color and lighting. In conclusion, volume rendering is a promising technique to elaborate three-dimensional images, offering very realistic endoscopic views. At present, the main limitation is represented by the need of powerful and high-cost workstations.
Ryan, William R; Ramachandra, Tara; Hwang, Peter H
2011-03-01
To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.
Evaluation of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope
NASA Astrophysics Data System (ADS)
Yoshimoto, Kayo; Watabe, Kenji; Fujinaga, Tetsuji; Iijima, Hideki; Tsujii, Masahiko; Takahashi, Hideya; Takehara, Tetsuo; Yamada, Kenji
2017-02-01
Because the view angle of the endoscope is narrow, it is difficult to get the whole image of the digestive tract at once. If there are more than two lesions in the digestive tract, it is hard to understand the 3D positional relationship among the lesions. Virtual endoscopy using CT is a present standard method to get the whole view of the digestive tract. Because the virtual endoscopy is designed to detect the irregularity of the surface, it cannot detect lesions that lack irregularity including early cancer. In this study, we propose a method of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope. The method is as follows: 1) capture sequential images of the digestive tract by moving the endoscope, 2) reconstruct 3D surface pattern for each frame by stereo images, 3) estimate the position of the endoscope by image analysis, 4) reconstitute the entire image of the digestive tract by combining the 3D surface pattern. To confirm the validity of this method, we experimented with a straight tube inside of which circles were allocated at equal distance of 20 mm. We captured sequential images and the reconstituted image of the tube revealed that the distance between each circle was 20.2 +/- 0.3 mm (n=7). The results suggest that this method of endoscopic entire 3D image acquisition may help us understand 3D positional relationship among the lesions such as early esophageal cancer that cannot be detected by virtual endoscopy using CT.
Virtual endoscopic imaging of the spine.
Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei
2012-05-20
Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.
Real-time fusion of endoscopic views with dynamic 3-D cardiac images: a phantom study.
Szpala, Stanislaw; Wierzbicki, Marcin; Guiraudon, Gerard; Peters, Terry M
2005-09-01
Minimally invasive robotically assisted cardiac surgical systems currently do not routinely employ 3-D image guidance. However, preoperative magnetic resonance and computed tomography (CT) images have the potential to be used in this role, if appropriately registered with the patient anatomy and animated synchronously with the motion of the actual heart. This paper discusses the fusion of optical images of a beating heart phantom obtained from an optically tracked endoscope, with volumetric images of the phantom created from a dynamic CT dataset. High quality preoperative dynamic CT images are created by first extracting the motion parameters of the heart from the series of temporal frames, and then applying this information to animate a high-quality heart image acquired at end systole. Temporal synchronization of the endoscopic and CT model is achieved by selecting the appropriate CT image from the dynamic set, based on an electrocardiographic trigger signal. The spatial error between the optical and virtual images is 1.4 +/- 1.1 mm, while the time discrepancy is typically 50-100 ms. Index Terms-Image guidance, image warping, minimally invasive cardiac surgery, virtual endoscopy, virtual reality.
[Virtual bronchoscopy: the correlation between endoscopic simulation and bronchoscopic findings].
Salvolini, L; Gasparini, S; Baldelli, S; Bichi Secchi, E; Amici, F
1997-11-01
We carried out a preliminary clinical validation of 3D spiral CT virtual endoscopic reconstructions of the tracheobronchial tree, by comparing virtual bronchoscopic images with actual endoscopic findings. Twenty-two patients with tracheobronchial disease suspected at preliminary clinical, cytopathological and plain chest film findings were submitted to spiral CT of the chest and bronchoscopy. CT was repeated after endobronchial therapy in 2 cases. Virtual endoscopic shaded-surface-display views of the tracheobronchial tree were reconstructed from reformatted CT data with an Advantage Navigator software. Virtual bronchoscopic images were preliminarily evaluated with a semi-quantitative quality score (excellent/good/fair/poor). The depiction of consecutive airway branches was then considered. Virtual bronchoscopies were finally submitted to double-blind comparison with actual endoscopies. Virtual image quality was considered excellent in 8 cases, good in 14 and fair in 2. Virtual exploration was stopped at the lobar bronchi in one case only; the origin of segmental bronchi was depicted in 23 cases and that of some subsegmental branches in 2 cases. Agreement between actual and virtual bronchoscopic findings was good in all cases but 3 where it was nevertheless considered satisfactory. The yield of clinically useful information differed in 8/24 cases: virtual reconstructions provided more information than bronchoscopy in 5 cases and vice versa in 3. Virtual reconstructions are limited in that the procedure is long and difficult and needing a strictly standardized threshold value not to alter virtual findings. Moreover, the reconstructed surface lacks transparency, there is the partial volume effect and the branches < or = 4 pixels phi and/or meandering ones are difficult to explore. Our preliminary data are encouraging. Segmental bronchi were depicted in nearly all cases, except for the branches involved by disease. Obstructing lesions could be bypassed in some cases, making an indication for endoscopic laser therapy. Future didactic perspectives and applications to minimally invasive or virtual reality-assisted therapy seem promising, even though actual clinical applications require further studies.
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis
Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240
NASA Astrophysics Data System (ADS)
Hunt, Gordon W.; Hemler, Paul F.; Vining, David J.
1997-05-01
Virtual colonscopy (VC) is a minimally invasive alternative to conventional fiberoptic endoscopy for colorectal cancer screening. The VC technique involves bowel cleansing, gas distension of the colon, spiral computed tomography (CT) scanning of a patient's abdomen and pelvis, and visual analysis of multiplanar 2D and 3D images created from the spiral CT data. Despite the ability of interactive computer graphics to assist a physician in visualizing 3D models of the colon, a correct diagnosis hinges upon a physician's ability to properly identify small and sometimes subtle polyps or masses within hundreds of multiplanar and 3D images. Human visual analysis is time-consuming, tedious, and often prone to error of interpretation.We have addressed the problem of visual analysis by creating a software system that automatically highlights potential lesions in the 2D and 3D images in order to expedite a physician's interpretation of the colon data.
Computed Tomography Evaluation of Esophagogastric Necrosis After Caustic Ingestion.
Chirica, Mircea; Resche-Rigon, Matthieu; Zagdanski, Anne Marie; Bruzzi, Matthieu; Bouda, Damien; Roland, Eric; Sabatier, François; Bouhidel, Fatiha; Bonnet, Francine; Munoz-Bongrand, Nicolas; Marc Gornet, Jean; Sarfati, Emile; Cattan, Pierre
2016-07-01
Endoscopy is the standard of care for emergency patient evaluation after caustic ingestion. However, the inaccuracy of endoscopy in determining the depth of intramural necrosis may lead to inappropriate decision-making with devastating consequences. Our aim was to evaluate the use of computed tomography (CT) for the emergency diagnostic workup of patients with caustic injuries. In a prospective study, we used a combined endoscopy-CT decision-making algorithm. The primary outcome was pathology-confirmed digestive necrosis. The respective utility of CT and endoscopy in the decision-making process were compared. Transmural endoscopic necrosis was defined as grade 3b injuries; signs of transmural CT necrosis included absence of postcontrast gastric/ esophageal-wall enhancement, esophageal-wall blurring, and periesophageal-fat blurring. We included 120 patients (59 men, median age 44 years). Emergency surgery was performed in 24 patients (20%) and digestive resection was completed in 16. Three patients (3%) died and 28 patients (23%) experienced complications. Pathology revealed transmural necrosis in 9/11 esophagectomy and 16/16 gastrectomy specimens. Severe oropharyngeal injuries (P = 0.015), increased levels of blood lactate (P = 0.007), alanine aminotransferase (P = 0.027), bilirubin (P = 0.005), and low platelet counts (P > 0.0001) were predictive of digestive necrosis. Decision-making relying on CT alone or on a combined CT-endoscopy algorithm was similar and would have spared 19 unnecessary esophagectomies and 16 explorative laparotomies compared with an endoscopy-alone algorithm. Endoscopy did never rectify a wrong CT decision. Emergency decision-making after caustic injuries can rely on CT alone.
Virtual reality simulators for gastrointestinal endoscopy training
Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D
2014-01-01
The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees’ learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application. PMID:24527175
... ARS HOME ANATOMY Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ... ANATOMY > Sinus Anatomy Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ...
MDCT imaging of the stomach: advances and applications
Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish
2017-01-01
The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE. PMID:27785936
MDCT imaging of the stomach: advances and applications.
Nagpal, Prashant; Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish
2017-01-01
The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE.
Virtual endoscopy in neurosurgery: a review.
Neubauer, André; Wolfsberger, Stefan
2013-01-01
Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.
Bhojani, Naeem; Paonessa, Jessica E; El Tayeb, Marawan M; Williams, James C; Hameed, Tariq A; Lingeman, James E
2018-04-03
To compare the sensitivity of noncontrast computed tomography (CT) with endoscopy for detection of renal calculi. Imaging modalities for detection of nephrolithiasis have centered on abdominal x-ray, ultrasound, and noncontrast CT. Sensitivities of 58%-62% (abdominal x-ray), 45% (ultrasound), and 95%-100% (CT) have been previously reported. However, these results have never been correlated with endoscopic findings. Idiopathic calcium oxalate stone formers with symptomatic calculi requiring ureteroscopy were studied. At the time of surgery, the number and the location of all calculi within the kidney were recorded followed by basket retrieval. Each calculus was measured and sent for micro-CT and infrared spectrophotometry. All CT scans were reviewed by the same genitourinary radiologist who was blinded to the endoscopic findings. The radiologist reported on the number, location, and size of each calculus. Eighteen renal units were studied in 11 patients. Average time from CT scan to ureteroscopy was 28.6 days. The mean number of calculi identified per kidney was 9.2 ± 6.1 for endoscopy and 5.9 ± 4.1 for CT (P <.004). The mean size of total renal calculi (sum of the longest stone diameters) per kidney was 22.4 ± 17.1 mm and 18.2 ± 13.2 mm for endoscopy and CT, respectively (P = .06). CT scan underreports the number of renal calculi, probably missing some small stones and being unable to distinguish those lying in close proximity to one another. However, the total stone burden seen by CT is, on average, accurate when compared with that found on endoscopic examination. Copyright © 2018 Elsevier Inc. All rights reserved.
Virtual reality simulation training for health professions trainees in gastrointestinal endoscopy.
Walsh, Catharine M; Sherlock, Mary E; Ling, Simon C; Carnahan, Heather
2012-06-13
Traditionally, training in gastrointestinal endoscopy has been based upon an apprenticeship model, with novice endoscopists learning basic skills under the supervision of experienced preceptors in the clinical setting. Over the last two decades, however, the growing awareness of the need for patient safety has brought the issue of simulation-based training to the forefront. While the use of simulation-based training may have important educational and societal advantages, the effectiveness of virtual reality gastrointestinal endoscopy simulators has yet to be clearly demonstrated. To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. Health professions, educational and computer databases were searched until November 2011 including The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, Scopus, Web of Science, Biosis Previews, CINAHL, Allied and Complementary Medicine Database, ERIC, Education Full Text, CBCA Education, Career and Technical Education @ Scholars Portal, Education Abstracts @ Scholars Portal, Expanded Academic ASAP @ Scholars Portal, ACM Digital Library, IEEE Xplore, Abstracts in New Technologies and Engineering and Computer & Information Systems Abstracts. The grey literature until November 2011 was also searched. Randomised and quasi-randomised clinical trials comparing virtual reality endoscopy (oesophagogastroduodenoscopy, colonoscopy and sigmoidoscopy) simulation training versus any other method of endoscopy training including conventional patient-based training, in-job training, training using another form of endoscopy simulation (e.g. low-fidelity simulator), or no training (however defined by authors) were included. Trials comparing one method of virtual reality training versus another method of virtual reality training (e.g. comparison of two different virtual reality simulators) were also included. Only trials measuring outcomes on humans in the clinical setting (as opposed to animals or simulators) were included. Two authors (CMS, MES) independently assessed the eligibility and methodological quality of trials, and extracted data on the trial characteristics and outcomes. Due to significant clinical and methodological heterogeneity it was not possible to pool study data in order to perform a meta-analysis. Where data were available for each continuous outcome we calculated standardized mean difference with 95% confidence intervals based on intention-to-treat analysis. Where data were available for dichotomous outcomes we calculated relative risk with 95% confidence intervals based on intention-to-treat-analysis. Thirteen trials, with 278 participants, met the inclusion criteria. Four trials compared simulation-based training with conventional patient-based endoscopy training (apprenticeship model) whereas nine trials compared simulation-based training with no training. Only three trials were at low risk of bias. Simulation-based training, as compared with no training, generally appears to provide participants with some advantage over their untrained peers as measured by composite score of competency, independent procedure completion, performance time, independent insertion depth, overall rating of performance or competency error rate and mucosal visualization. Alternatively, there was no conclusive evidence that simulation-based training was superior to conventional patient-based training, although data were limited. The results of this systematic review indicate that virtual reality endoscopy training can be used to effectively supplement early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. However, there remains insufficient evidence to advise for or against the use of virtual reality simulation-based training as a replacement for early conventional endoscopy training (apprenticeship model) for health professions trainees with limited or no prior endoscopic experience. There is a great need for the development of a reliable and valid measure of endoscopic performance prior to the completion of further randomised clinical trials with high methodological quality.
Virtual endoscopy using spherical QuickTime-VR panorama views.
Tiede, Ulf; von Sternberg-Gospos, Norman; Steiner, Paul; Höhne, Karl Heinz
2002-01-01
Virtual endoscopy needs some precomputation of the data (segmentation, path finding) before the diagnostic process can take place. We propose a method that precomputes multinode spherical panorama movies using Quick-Time VR. This technique allows almost the same navigation and visualization capabilities as a real endoscopic procedure, a significant reduction of interaction input is achieved and the movie represents a document of the procedure.
ACR Appropriateness Criteria® Nonvariceal Upper Gastrointestinal Bleeding.
Singh-Bhinder, Nimarta; Kim, David H; Holly, Brian P; Johnson, Pamela T; Hanley, Michael; Carucci, Laura R; Cash, Brooks D; Chandra, Ankur; Gage, Kenneth L; Lambert, Drew L; Levy, Angela D; Oliva, Isabel B; Peterson, Christine M; Strax, Richard; Rybicki, Frank J; Dill, Karin E
2017-05-01
Upper gastrointestinal bleeding (UGIB) remains a significant cause of morbidity and mortality with mortality rates as high as 14%. This document addresses the indications for imaging UGIB that is nonvariceal and unrelated to portal hypertension. The four variants are derived with respect to upper endoscopy. For the first three, it is presumed that upper endoscopy has been performed, with three potential initial outcomes: endoscopy reveals arterial bleeding source, endoscopy confirms UGIB without a clear source, and negative endoscopy. The fourth variant, "postsurgical and traumatic causes of UGIB; endoscopy contraindicated" is considered separately because upper endoscopy is not performed. When endoscopy identifies the presence and location of bleeding but bleeding cannot be controlled endoscopically, catheter-based arteriography with treatment is an appropriate next study. CT angiography (CTA) is comparable with angiography as a diagnostic next step. If endoscopy demonstrates a bleed but the endoscopist cannot identify the bleeding source, angiography or CTA can be typically performed and both are considered appropriate. In the event of an obscure UGIB, angiography and CTA have been shown to be equivalent in identifying the bleeding source; CT enterography may be an alternative to CTA to find an intermittent bleeding source. In the postoperative or traumatic setting when endoscopy is contraindicated, primary angiography, CTA, and CT with intravenous contrast are considered appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Role of virtual reality simulation in endoscopy training
Harpham-Lockyer, Louis; Laskaratos, Faidon-Marios; Berlingieri, Pasquale; Epstein, Owen
2015-01-01
Recent advancements in virtual reality graphics and models have allowed virtual reality simulators to be incorporated into a variety of endoscopic training programmes. Use of virtual reality simulators in training programmes is thought to improve skill acquisition amongst trainees which is reflected in improved patient comfort and safety. Several studies have already been carried out to ascertain the impact that usage of virtual reality simulators may have upon trainee learning curves and how this may translate to patient comfort. This article reviews the available literature in this area of medical education which is particularly relevant to all parties involved in endoscopy training and curriculum development. Assessment of the available evidence for an optimal exposure time with virtual reality simulators and the long-term benefits of their use are also discussed. PMID:26675895
Role of virtual reality simulation in endoscopy training.
Harpham-Lockyer, Louis; Laskaratos, Faidon-Marios; Berlingieri, Pasquale; Epstein, Owen
2015-12-10
Recent advancements in virtual reality graphics and models have allowed virtual reality simulators to be incorporated into a variety of endoscopic training programmes. Use of virtual reality simulators in training programmes is thought to improve skill acquisition amongst trainees which is reflected in improved patient comfort and safety. Several studies have already been carried out to ascertain the impact that usage of virtual reality simulators may have upon trainee learning curves and how this may translate to patient comfort. This article reviews the available literature in this area of medical education which is particularly relevant to all parties involved in endoscopy training and curriculum development. Assessment of the available evidence for an optimal exposure time with virtual reality simulators and the long-term benefits of their use are also discussed.
Ingram, W Scott; Yang, Jinzhong; Wendt, Richard; Beadle, Beth M; Rao, Arvind; Wang, Xin A; Court, Laurence E
2017-08-01
To assess the influence of non-rigid anatomy and differences in patient positioning between CT acquisition and endoscopic examination on endoscopy-CT image registration in the head and neck. Radiotherapy planning CTs and 31-35 daily treatment-room CTs were acquired for nineteen patients. Diagnostic CTs were acquired for thirteen of the patients. The surfaces of the airways were segmented on all scans and triangular meshes were created to render virtual endoscopic images with a calibrated pinhole model of an endoscope. The virtual images were used to take projective measurements throughout the meshes, with reference measurements defined as those taken on the planning CTs and test measurements defined as those taken on the daily or diagnostic CTs. The influence of non-rigid anatomy was quantified by 3D distance errors between reference and test measurements on the daily CTs, and the influence of patient positioning was quantified by 3D distance errors between reference and test measurements on the diagnostic CTs. The daily CT measurements were also used to investigate the influences of camera-to-surface distance, surface angle, and the interval of time between scans. Average errors in the daily CTs were 0.36 ± 0.61 cm in the nasal cavity, 0.58 ± 0.83 cm in the naso- and oropharynx, and 0.47 ± 0.73 cm in the hypopharynx and larynx. Average errors in the diagnostic CTs in those regions were 0.52 ± 0.69 cm, 0.65 ± 0.84 cm, and 0.69 ± 0.90 cm, respectively. All CTs had errors heavily skewed towards 0, albeit with large outliers. Large camera-to-surface distances were found to increase the errors, but the angle at which the camera viewed the surface had no effect. The errors in the Day 1 and Day 15 CTs were found to be significantly smaller than those in the Day 30 CTs (P < 0.05). Inconsistencies of patient positioning have a larger influence than non-rigid anatomy on projective measurement errors. In general, these errors are largest when the camera is in the superior pharynx, where it sees large distances and a lot of muscle motion. The errors are larger when the interval of time between CT acquisitions is longer, which suggests that the interval of time between the CT acquisition and the endoscopic examination should be kept short. The median errors found in this study are comparable to acceptable levels of uncertainty in deformable CT registration. Large errors are possible even when image alignment is very good, indicating that projective measurements must be made carefully to avoid these outliers. © 2017 American Association of Physicists in Medicine.
Iwamuro, Masaya; Tanaka, Shouichi; Moritou, Yuki; Inaba, Tomoki; Higashi, Reiji; Kusumoto, Chiaki; Yunoki, Naoko; Ishikawa, Shin; Okamoto, Yuko; Kawai, Yoshinari; Kitada, Ken-Ichi; Takenaka, Ryuta; Toyokawa, Tatsuya; Okada, Hiroyuki
2017-06-01
Most gastric bezoars can be treated with endoscopic fragmentation combined with or without cola dissolution, whereas laparotomy or laparoscopic surgery is generally inevitable for small intestinal bezoars because they cause small bowel obstruction. Therefore, early diagnosis and management of gastric bezoars are necessary to prevent bezoar-induced ileus. To investigate the incidence of overlooked gastric bezoars during the initial esophagogastroduodenoscopy, we retrospectively reviewed the cases of 27 patients diagnosed with gastrointestinal bezoars. The bezoars were diagnosed using esophagogastroduodenoscopy (n=25), abdominal ultrasonography (n=1), and barium follow-through examination (n=1). Bezoars were overlooked in 9/25 patients (36.0%) during the initial endoscopy examination because the bezoars were covered with debris in the stomach. Of the 9 patients, 8 had concomitant gastric ulcers, and the other patient had gastric lymphoma. Although a computed tomography (CT) scan was performed before the second-look endoscopy in 8 of the 9 patients, the bezoars were mistaken as food debris on CT findings and were overlooked in these patients. In conclusion, gastric bezoars may not be discovered during the initial esophagogastroduodenoscopy and CT scan. In cases with debris in the stomach, second-look endoscopy is essential to detect bezoars.
Comparison between Awake Endoscopy and Computed Tomography to Define Lingual Tonsil Hypertrophy.
Tang, Jessica A; Gorelick, Gleb; Friedman, Michael
2017-11-01
Objectives To analyze correlations between endoscopic lingual tonsil grade (LTG) by the Friedman Lingual Tonsil Hypertrophy grading system and computed tomography (CT) measurements of lingual tonsil thickness (LTT). Study Design Retrospective chart review. Setting Single-center database, September 2016 to April 2017. Subjects and Methods Patients who received CT covering base of tongue and endoscopic LTG were included. LTT was measured on axial and sagittal CT. LTT measurements were compared against endoscopic LTG. One-way analysis of variance with Tukey's post hoc adjustment for multiple comparisons was performed. Results Seventy-five charts were included for a total of 150 LTT measurements. Axial CT measurements of LTG 1 and LTG 2 were each significantly different from LTG 3 ( P < .001 for both), and LTG 1 and LTG 2 also differed significantly ( P = .010). Mean sagittal CT measurements were significantly different between LTG 1 and LTG 3 ( P < .001) and between LTG 2 and LTG 3 ( P = .002) but not between LTG 1 and LTG 2 ( P = .186). Those without lingual tonsil hypertrophy had a mean axial CT thickness of 6.45 ± 1.39 mm and mean sagittal CT thickness of 6.58 ± 1.53 mm, which was significantly different from both the mean axial CT thickness of 8.48 ± 1.52 mm and the mean sagittal CT thickness of 8.07 ± 1.16 mm in the LTG 3 group ( P < .001 for both). Threshold analysis showed a potential cutoff of approximately 7.5 mm on axial and sagittal CT for defining clinically significant lingual tonsil hypertrophy. Conclusion Awake endoscopy grading of lingual tonsil hypertrophy is a subjective measurement that seems to correlate with objective CT measurements. LTT measurements of LTG 1 and LTG 2 on awake endoscopy differed significantly from LTG 3.
Strauss, Christiane; Mal, Frederic; Perniceni, Thierry; Bouzar, Nadia; Lenoir, Stephane; Gayet, Brice; Palau, Robert
2010-04-01
Water-soluble contrast swallow (CS) is usually performed before refeeding for anastomosis assessment after esophagectomy with intrathoracic anastomosis but the sensitivity of CS is low. Another diagnostic approach is based on analysis of computed tomography (CT) scan with oral contrast and of CT mediastinal air images. We undertook to compare them prospectively. Ninety-seven patients with an esophageal carcinoma operated by intrathoracic anastomosis were included prospectively in a study based on a CT scan at postoperative day 3 (without oral and intravenous contrast) and CT scan and CS at day 7. CT scan analysis consisted of assessing contrast and air leakage. In case of doubt, an endoscopy was done. A diagnosis of anastomotic leak was made in 13 patients (13.4%), in 2 cases before day 7 and in 3 beyond day 7. At day 3, 94 CT scans were performed, but the diagnostic value was poor. In 95 patients with both CS and CT scan at day 7, CS disclosed a leak in 5 of 11, and CT scan was abnormal in 8 of 11. Leakage of contrast and/or presence of mediastinal gas had the best negative predictive value (95.8%). Endoscopy was done in 16 patients with only mediastinal gas at day 7 CT scan. It disclosed a normal anastomosis in 11, fibrin deposits in 4, and a leak in 1. In comparison with CS only, CT at day 7 improves the sensitivity and negative predictive value for diagnosing an anastomotic leak. In case of doubt endoscopy is advisable. This approach provides an accurate assessment of the anastomosis before refeeding.
18F-FDG uptake and its clinical relevance in primary gastric lymphoma.
Yi, Jun Ho; Kim, Seok Jin; Choi, Joon Young; Ko, Young Hyeh; Kim, Byung-Tae; Kim, Won Seog
2010-06-01
We studied the clinical relevance of (18)F-fluorodeoxyglucose ((18)F-FDG) uptake in patients with primary gastric lymphoma underwent positron emission tomography (PET)/ computed tomography (CT) scan. Forty-two patients with primary gastric lymphoma were analysed: 32 diffuse large B-cell lymphomas (DLBCL) and 10 extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue (MALT lymphomas). The PET/CT scans were compared with clinical and pathologic features, and the results of CT and endoscopy. Nine patients were up-staged based on the results of their PET/CT scan compared to CT (seven DLBCLs, two MALT lymphomas) while six patients were down-staged by the PET/CT scan. The standard uptake value (SUV) was used as an indicator of a lesion with a high metabolic rate. The high SUVmax group, defined as an SUVmax >or= median value, was significantly associated with an advanced Lugano stage (p < 0.001). Three patients with DLBCL, who showed an initially high SUVmax, died of disease progression. Among 24 patients for whom follow-up PET/CT scan with endoscopy was performed, 11 patients with ulcerative or mucosal lesions showed residual (18)F-FDG uptake. All of these gastric lesions were grossly and pathologically benign lesions without evidence of lymphoma cells. In conclusion, PET/CT scan can be used in staging patients with primary gastric lymphoma; however, the residual (18)F-FDG uptake observed during follow-up should be interpreted cautiously and should be combined with endoscopy and multiple biopsies of the stomach. (c) 2009 John Wiley & Sons, Ltd.
Boal Carvalho, Pedro; Magalhães, Joana; Dias de Castro, Francisca; Gonçalves, Tiago Cúrdia; Rosa, Bruno; Moreira, Maria João; Cotter, José
2016-02-01
Small bowel capsule endoscopy represents the initial investigation for obscure gastrointestinal bleeding. Flexible spectral imaging colour enhancement (FICE) is a virtual chromoendoscopy technique designed to enhance mucosal lesions, available in different settings according to light wavelength-- FICE1, 2 and 3. To compare the diagnostic yield of FICE1 and white light during capsule endoscopy in patients with obscure gastrointestinal bleeding. Retrospective single-centre study including 60 consecutive patients referred for small bowel capsule endoscopy for obscure gastrointestinal bleeding. Endoscopies were independently reviewed in FICE1 and white light; findings were then reviewed by another researcher, establishing a gold standard. Diagnostic yield was defined as the presence of lesions with high bleeding potential (P2) angioectasias, ulcers or tumours. Diagnostic yield using FICE1 was significantly higher than white light (55% vs. 42%, p=0.021). A superior number of P2 lesions was detected with FICE1 (74 vs. 44, p=0.003), particularly angioectasias (54 vs. 26, p=0.002), but not ulcers or tumours. FICE1 was significantly superior to white light, resulting in a 13% improvement in diagnostic yield, and potentially bleeding lesions particularly angioectasias were more often observed. Our results support the use of FICE1 while reviewing small bowel capsule endoscopy for obscure gastrointestinal bleeding. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Mixed virtual reality simulation--taking endoscopic simulation one step further.
Courteille, O; Felländer-Tsai, L; Hedman, L; Kjellin, A; Enochsson, L; Lindgren, G; Fors, U
2011-01-01
This pilot study aimed to assess medical students' appraisals of a "mixed" virtual reality simulation for endoscopic surgery (with a virtual patient case in addition to a virtual colonoscopy) as well as the impact of this simulation set-up on students' performance. Findings indicate that virtual patients can enhance contextualization of simulated endoscopy and thus facilitate an authentic learning environment, which is important in order to increase motivation.
Liu Bejarano, Humberto
2011-01-01
Due to the poor agreement between endoscopy and histology, the gastric biopsy continues being the gold standard for the diagnosis of atrophic chronic gastritis. The Virtual chromoendoscopy system allows better observation of the gastric mucosa. Evaluate the agreement between the Kimura-Takemoto ´s endoscopic system classification and the histological system of OLGA (Operative for Link Assessment Gastritis), as well as to evaluate the application of the virtual chromoendoscopy. A prospective and longitudinal study of cohorts, 138 patients was include, using endoscopic system of atrophy by Kimura and Takemoto (K-T), with conventional optical and with the use of seventh filter of virtual chromoendoscopy ,then comparing with the histological findings of the OLGA pathology system, also were determinated injuries associated with respect to stage OLGA. The kappa index of agreement between conventional endoscopy and the system OLGA was 0.859 and with the system of virtual chromoendoscopy was 0.822, the preneoplasic and neoplastic gastric lesions were associate to stages III and IV of atrophy. The endoscopic and histological correlation with both systems isvery good, with or without the use of virtual chromoendoscopy. chronic atrophic gastritis, virtual chromoendoscopy, olga system, , kimuratakemoto system.
Machiels, Melanie; van Hooft, Jeanin; Jin, Peng; van Berge Henegouwen, Mark I; van Laarhoven, Hanneke M; Alderliesten, Tanja; Hulshof, Maarten C
2015-10-01
Markers placed at the borders of esophageal tumors are potentially useful to facilitate radiotherapy (RT) target delineation, which offers the possibility of image-guided RT. To evaluate and compare the feasibility and technical benefit of endoscopy/EUS-guided marker placement of 3 different types of markers in patients with esophageal cancer referred for RT. Prospective, single-center, feasibility and comparative study. Tertiary-care medical center. Thirty patients with esophageal cancer who were referred for RT. Patients underwent endoscopy/EUS-guided implantation of 1 type of marker. A solid gold marker (SM) with fixed dimensions, a flexible coil-shaped gold marker (FM) with hand-cut length (2-10 mm), and a radiopaque hydrogel marker (HG) were used. Technical feasibility and adverse events were registered. CT scans and cone-beam CT scans (CBCT) acquired during RT were analyzed to determine and compare the visibility and continuous clear visibility of the implanted markers. Technical feasibility, technical benefit, and adverse events of 3 types of markers. A total of 101 markers were placed in 30 patients. Implantation was technically feasible in all patients without grade 3 to 4 adverse events. Two patients with asymptomatic mediastinitis and one with asymptomatic pneumothorax were seen. Visibility on CT scan of all 3 types of implanted markers was adequate for target delineation. Eighty percent of FMs remained continuously visible over the treatment period on CBCT, significantly better than SMs (63%) and HGs (11%) (P = .015). When we selected FMs ≥5 mm, 90.5% remained visible on CBCT between implantation and the end of RT. Single-center, nonrandomized design. Endoscopy/EUS-guided fiducial marker placement for esophageal cancer is both safe and feasible and can be used for target volume delineation purposes on CT. Our results imply a significant advantage of FMs over SMs and HGs, regarding visibility and continuous clear visibility over the treatment period. ( NTR4724.). Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Cabanis, Emmanuel-Alain; Gombergh, Rodolphe; Castro, Albert; Gandjbakhch, Iradj; Iba-Zizen, Marie-Thérèse; Dubois, François
2011-06-01
Progress in HR-CTdata processing has led to lower X-ray exposure and to better diagnostic performance. We describe 19 adult patients (among 5000) examined by HR CT with 64 detectors, acquisition and exposure protocols in mSv, spiral, 0.6-mm slices, 5To PACS. After the two usual processing steps (60 gray values, 5122 and 10242 matrices, dedicated workstations for coronaroscopy and virtual coloscopy, 2D multiplanar reformation, surfacic, 3D volumes with dissection and navigation), a third original data processing step on additional workstations was added. Variable matrix extrapolated images, flexible colored curves (different from anatomical conventions), lighting (sources) and transparencies (unavailable with traditional endoscopy) were used. The digital film is a 16-minute "journey "consisting of 19 endo-body navigations in 5 regions, from the head to the bronchi, from the heart to the coronary arteries, and from the digestive tract to the abdomen and pelvis. One possible application is post-operative verification of an aortic graft. The movie is illustrated here with ten plates. This new approach is cost-effective and beneficial for the patient, in terms of early diagnosis and therapeutic follow-up. Ethical issues are also examined.
Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi
2012-03-01
Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Usefulness of positron emission tomography in primary intestinal follicular lymphoma
Tari, Akira; Asaoku, Hideki; Kunihiro, Masaki; Tanaka, Shinji; Yoshino, Tadashi
2013-01-01
Double-balloon enteroscopy (DBE) and video capsule endoscopy are useful for the diagnosis of lymphoma in the small intestine. However, DBE cannot be safely performed in cases with passage disturbance due to wall thickening and stenosis. Additionally, video capsule endoscopy cannot be performed in such cases because of the risk of retention. Here, we report 4 cases of primary follicular lymphoma of the gastrointestinal tract that could be detected using 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (PET-CT). The endoscopic findings of these 4 cases included lesions with wall thickening, which comprised macroscopically clusters of nodules, dense clusters of whitish granules or small nodules, fold thickening and ulcers with irregular margins that occupied the whole lumen with edematous mucosa. All patients fulfilled the World Health Organization grade 1 criteria. 18F-fluorodeoxyglucose PET-CT can help predict the risks that may result from certain endoscopic examinations, such as DBE and video capsule endoscopy. PMID:23569346
Sinonasal fibrosarcoma: a case report.
Plaza, G; Ferrando, J; Pinedo, F
2006-07-01
Sinonasal fibrosarcoma (SFS) is an infrequent malignant neoplasm. It usually presents as other sarcomas in this region, with nasal obstruction and epistaxis. The final diagnosis is based on the histopathology and immunohistochemistry. We report the case of a 58-year-old man with an 8-month history of left proptosis, recurrent epistaxis and nasal obstruction. Nasal endoscopy confirmed a left nasal neoplasia. CT and MRI showed the extension of the neoplasia, occupying the left nasal fossa and ethmoid sinuses, and eroding the medial wall of the orbit. Complete removal was achieved through endoscopic sinus surgery, preserving the orbit. SFS was found on histopathologic examination. After 4 years of follow-up, nasal endoscopy, CT and MRI imaging show no sign of recurrence.
Cosmacini, P; Piacentini, P
2008-08-01
A few centuries after the practice of mummification was finally abolished in the seventh century A.D., mummies began to capture the collective imagination, exerting a mysterious fascination that continues to this day. From the beginning, the radiological study of Egyptian mummies permitted the collection not only of medical data but also of anthropological and archaeological evidence. The first radiological study of an Egyptian mummy was performed by Flinders Petrie shortly after the discovery of X-rays in 1895, and since then, radiology has never stopped investigating these special patients. By the end of the 1970s, computed tomography (CT) scanning permitted more in-depth studies to be carried out without requiring the mummies to be removed from their cartonnage. CT images can be used to obtain a three-dimensional reconstruction of the mummy that provides important new information, in part thanks to the virtual endoscopy technique known as "fly through". Moreover, starting from CT data and using sophisticated graphics software, one can reconstruct an image of the face of the mummified individual at the time of his or her death. The history of imaging, from its origins until now, from the simplest to the most sophisticated technique, allows us to appreciate why these studies have been, and still are, fundamental in the study of Egyptian mummies.
Virtual Reality and Simulation in Neurosurgical Training.
Bernardo, Antonio
2017-10-01
Recent biotechnological advances, including three-dimensional microscopy and endoscopy, virtual reality, surgical simulation, surgical robotics, and advanced neuroimaging, have continued to mold the surgeon-computer relationship. For developing neurosurgeons, such tools can reduce the learning curve, improve conceptual understanding of complex anatomy, and enhance visuospatial skills. We explore the current and future roles and application of virtual reality and simulation in neurosurgical training. Copyright © 2017 Elsevier Inc. All rights reserved.
Routine Use of Contrast Swallow After Total Gastrectomy and Esophagectomy: Is it Justified?
El-Sourani, Nader; Bruns, Helge; Troja, Achim; Raab, Hans-Rudolf; Antolovic, Dalibor
2017-01-01
After gastrectomy or esophagectomy, esophagogastrostomy and esophagojejunostomy are commonly used for reconstruction. Water-soluble contrast swallow is often used as a routine screening to exclude anastomotic leakage during the first postoperative week. In this retrospective study, the sensitivity and specificity of oral water-soluble contrast swallow for the detection of anastomotic leakage and its clinical symptoms were analysed. Records of 104 consecutive total gastrectomies and distal esophagectomies were analysed. In all cases, upper gastrointestinal contrast swallow with the use of a water-soluble contrast agent was performed on the 5 th postoperative day. Extravasation of the contrast agent was defined as anastomotic leakage. When anastomotic insufficiency was suspected but no extravasation was present, a computed tomography (CT) scan and upper endoscopy were performed. Oral contrast swallow detected 7 anastomotic leaks. Based on CT-scans and upper endoscopy, the true number of anastomotic leakage was 15. The findings of the oral contrast swallow were falsely positive in 4 and falsely negative in 12 patients, respectively. The sensitivity and specificity of the oral contrast swallow was 20% and 96%, respectively. Routine radiological contrast swallow following total gastrectomy or distal esophagectomy cannot be recommended. When symptoms of anastomotic leakage are present, a CT-scan and endoscopy are currently the methods of choice.
Seemann, M D; Claussen, C D
2001-06-01
A hybrid rendering method which combines a color-coded surface rendering method and a volume rendering method is described, which enables virtual endoscopic examinations using different representation models. 14 patients with malignancies of the lung and mediastinum (n=11) and lung transplantation (n=3) underwent thin-section spiral computed tomography. The tracheobronchial system and anatomical and pathological features of the chest were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures. For the virtual endoscopy of the tracheobronchial system, a shaded-surface model without color coding, a transparent color-coded shaded-surface model and a triangle-surface model were tested and compared. The hybrid rendering technique exploit the advantages of both rendering methods, provides an excellent overview of the tracheobronchial system and allows a clear depiction of the complex spatial relationships of anatomical and pathological features. Virtual bronchoscopy with a transparent color-coded shaded-surface model allows both a simultaneous visualization of an airway, an airway lesion and mediastinal structures and a quantitative assessment of the spatial relationship between these structures, thus improving confidence in the diagnosis of endotracheal and endobronchial diseases. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images. Virtual bronchoscopy with a transparent color-coded shaded-surface model offers a practical alternative to fiberoptic bronchoscopy and is particularly promising for patients in whom fiberoptic bronchoscopy is not feasible, contraindicated or refused. Furthermore, it can be used as a complementary procedure to fiberoptic bronchoscopy in evaluating airway stenosis and guiding bronchoscopic biopsy, surgical intervention and palliative therapy and is likely to be increasingly accepted as a screening method for people with suspected endobronchial malignancy and as control examination in the aftercare of patients with malignant diseases.
White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C
2014-06-01
Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p < 0.001). Residents who could be compared against themselves (pre vs. post-training), cecal intubation times decreased from 7.1 to 4.3 min (p < 0.001). Post-endoscopy rotation residents caused less severe discomfort during simulated colonoscopy than pre-endoscopy rotation residents (4 vs. 10%; p = 0.004). Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.
Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.
Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F
2013-09-01
The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.
Localized intraoperative virtual endoscopy (LIVE) for surgical guidance in 16 skull base patients.
Haerle, Stephan K; Daly, Michael J; Chan, Harley; Vescan, Allan; Witterick, Ian; Gentili, Fred; Zadeh, Gelareh; Kucharczyk, Walter; Irish, Jonathan C
2015-01-01
Previous preclinical studies of localized intraoperative virtual endoscopy-image-guided surgery (LIVE-IGS) for skull base surgery suggest a potential clinical benefit. The first aim was to evaluate the registration accuracy of virtual endoscopy based on high-resolution magnetic resonance imaging under clinical conditions. The second aim was to implement and assess real-time proximity alerts for critical structures during skull base drilling. Patients consecutively referred for sinus and skull base surgery were enrolled in this prospective case series. Five patients were used to check registration accuracy and feasibility with the subsequent 11 patients being treated under LIVE-IGS conditions with presentation to the operating surgeon (phase 2). Sixteen skull base patients were endoscopically operated on by using image-based navigation while LIVE-IGS was tested in a clinical setting. Workload was quantitatively assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Real-time localization of the surgical drill was accurate to ~1 to 2 mm in all cases. The use of 3-mm proximity alert zones around the carotid arteries and optic nerve found regular clinical use, as the median minimum distance between the tracked drill and these structures was 1 mm (0.2-3.1 mm) and 0.6 mm (0.2-2.5 mm), respectively. No statistical differences were found in the NASA-TLX indicators for this experienced surgical cohort. Real-time proximity alerts with virtual endoscopic guidance was sufficiently accurate under clinical conditions. Further clinical evaluation is required to evaluate the potential surgical benefits, particularly for less experienced surgeons or for teaching purposes. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S
2016-06-01
Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Kruglikova, Irina; Grantcharov, Teodor P; Drewes, Asbjorn M; Funch-Jensen, Peter
2010-02-01
Recently, virtual reality computer simulators have been used to enhance traditional endoscopy teaching. Previous studies have demonstrated construct validity of these systems and transfer of virtual skills to the operating room. However, to date no simulator-training curricula have been designed and there is very little evidence on the impact of external feedback on acquisition of endoscopic skills. The aim of the present study was to assess the impact of external feedback on the learning curves on a VR colonoscopy simulator using inexperienced trainees. 22 trainees, without colonoscopy experience were randomised to a group which received structured feedback provided by an experienced supervisor and a controlled group. All participants performed 15 repetitions of task 3 from the Introduction colonoscopy module of the Accu Touch Endoscopy simulator. Retention/transfer tests on simulator were performed 4-6 weeks after the last repetition. The proficiency levels were based on the performance of eight experienced colonoscopists. All subjects were able to complete the procedure on the simulator. There were no perforations in the feedback group versus seven in the non-feedback group. Subjects in the feedback group reached expert proficiency levels in percentage of mucosa visualised and time to reach the caecum significantly faster compared with the control group. None of the groups demonstrated significant degradation of performance in simulator retention/transfer tests. Concurrent feedback given by supervisor concur an advantage in acquisition of basic colonoscopy skills and achieving of proficiency level as compared to independent training.
Endoscopic training: A nationwide survey of French fellows in gastroenterology.
Amiot, Aurélien; Conroy, Guillaume; Le Baleur, Yann; Winkler, Jérôme; Palazzo, Maxime; Treton, Xavier
2018-04-01
During their 4 years of training, French fellows in gastroenterology should acquire theoretical and practical competency in gastrointestinal (GI) endoscopy. To evaluate the delivery of endoscopy training to French GI fellows and perception of learning. A nationwide electronic survey was carried out of French GI fellows using an anonymous, 17-item electronic questionnaire. A total of 291 out of 484 (60%) GI fellows responded to the survey. Only 40% of subjects had access to theoretical training and/or virtual simulators. Only 49% and 35% of fourth year fellows had reached the threshold numbers of EGD and colonoscopies recommended by the European section and Board of gastroenterology and hepatology. Sixty-two percent and 57% of trainees reported having insufficient knowledge in interpreting gastric and colic lesions. Access to dedicated endoscopy activity for at least 8 weeks during the year was the only independent factor associated with the achievement of the recommended annual threshold number of procedures. The access of fellows to theoretical training and to preclinical virtual simulators is still insufficient. Personalized support and regular assessment of cognitive and technical acquisition over the 4 years of training seems to be necessary. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, S; Rao, A; Wendt, R
Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the cameramore » by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination.« less
Nasal endoscopy and CT study of Pharaonic and Roman mummies.
Gaafar, H; Abdel-Monem, M H; Elsheikh, S
1999-03-01
In ancient Egypt mummifications were first carried out around 3000 BC. The visceral organs (lungs, stomach, liver and bowel) were removed from the body, cleansed, desiccated and placed in four canopic jars. The brain was removed from the body but was not preserved. Exactly how removal of the brain was accomplished is not clear. This study investigated the route of brain removal during mummification. Nasal endoscopy was carried out on 20 Pharaonic and Roman mummies. CT examination was performed on 2 mummy heads. In all mummies a communication between the cranial and nasal cavities was found passing through the posterior ethmoids and cribriform plates. The cranial cavity was empty. Our results demonstrate that brain removal during mummification was performed endonasally by trained personnel with a good knowledge of anatomy, using special instruments capable of creating a clean-cut endonasal craniotomy.
Lee, Whal; Kim, Ho Sung; Kim, Seok Jung; Kim, Hyung Ho; Chung, Jin Wook; Kang, Heung Sik; Choi, Ja-Young
2004-01-01
Objective To determine the diagnostic accuracy of CT arthrography and virtual arthroscopy in the diagnosis of anterior cruciate ligament and meniscus pathology. Materials and Methods Thirty-eight consecutive patients who underwent CT arthrography and arthroscopy of the knee were included in this study. The ages of the patients ranged from 19 to 52 years and all of the patients were male. Sagittal, coronal, transverse and oblique coronal multiplanar reconstruction images were reformatted from CT arthrography. Virtual arthroscopy was performed from 6 standard views using a volume rendering technique. Three radiologists analyzed the MPR images and two orthopedic surgeons analyzed the virtual arthroscopic images. Results The sensitivity and specificity of CT arthrography for the diagnosis of anterior cruciate ligament abnormalities were 87.5%-100% and 93.3-96.7%, respectively, and those for meniscus abnormalities were 91.7%-100% and 98.1%, respectively. The sensitivity and specificity of virtual arthroscopy for the diagnosis of anterior cruciate ligament abnormalities were 87.5% and 83.3-90%, respectively, and those for meniscus abnormalities were 83.3%-87.5% and 96.1-98.1%, respectively. Conclusion CT arthrography and virtual arthroscopy showed good diagnostic accuracy for anterior cruciate ligament and meniscal abnormalities. PMID:15064559
Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun
2018-07-01
This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.
Duan, Xinhui; Arbique, Gary; Guild, Jeffrey; Xi, Yin; Anderson, Jon
2018-05-01
The purpose of this study was to evaluate the quantitative accuracy of spectral images from a detector-based spectral CT scanner using a phantom with iodine-loaded inserts. A 40-cm long-body phantom with seven iodine inserts (2-20 mg/ml of iodine) was used in the study. The inserts could be placed at 5.5 or 10.5 cm from the phantom axis. The phantom was scanned five times for each insert configuration using 120 kVp tube voltage. A set of iodine, virtual noncontrast, effective atomic number, and virtual monoenergetic spectral CT images were generated and measurements were made for all the iodine rods. Measured values were compared with reference values calculated from the chemical composition information provided by the phantom manufacturer. Radiation dose from the spectral CT was compared to a conventional CT using a CTDI (32 cm) phantom. Good agreement between measurements and reference values was achieved for all types of spectral images. The differences ranged from -0.46 to 0.1 mg/ml for iodine concentration, -9.95 to 6.41 HU for virtual noncontrast images, 0.12 to 0.35 for effective Z images, and -17.7 to 55.7 HU for virtual monoenergetic images. For a similar CTDIvol, image noise from the conventional CT was 10% lower than the spectral CT. The detector-based spectral CT can achieve accurate spectral measurements on iodine concentration, virtual non-contrast images, effective atomic numbers, and virtual monoenergetic images. © 2018 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-09-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (C{{V}RHD} ) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology.
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan
2017-01-01
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (MeanRHD, and STDRHD CVRHD) of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and virtual nodules. Percent differences between them were less than 3% for all insertion techniques and were not statistically significant in most cases. Correlation coefficient values were greater than 0.97. The deformation according to the Hausdorff distance was also similar between the CT-derived and virtual nodules with minimal statistical significance in the (CVRHD) for Techniques A, B, and C. This study shows that both projection-based and image-based nodule insertion techniques yield realistic nodule renderings with statistical similarity to the synthetic nodules with respect to nodule volume and deformation. These techniques could be used to create a database of hybrid CT images containing nodules of known size, location and morphology. PMID:28786399
Zhang, Luo; Han, De-min; Ge, Wen-tong; Zhou, Bing; Xian, Jun-fang; Liu, Zhong-yan; Wang, Kui-ji; He, Fei
2005-12-01
To investigate the anatomical interaction between uncinate process and agger nasi cell to better understand the anatomy of the frontal sinus drainage pathway by endoscopy, spiral computed tomography (CT) and sectioning. Twenty-one skeletal skulls (forty-two sides) and one cadaver head (two sides) were studied by spiral CT together with endoscopy and collodion embedded thin sectioning at coronal plane. The sections with the thickness of 100 microm were stained with hemotoxylin and eosin. Under endoscopy, a leaflet of bone to the middle turbinate, which is given off by uncinate process, forms the anterior insertion of the middle turbinate onto the lateral nasal wall. The middle portion of the uncinate process attached to the frontal process of the maxilla in all of the skeletal nasal cavities, as well as the lacrimal bone in 78.6% of the skeletal nasal cavities. On CT scans, the agger nasi cell is present in 90.5% of the skeletal nasal cavities. While the lateral wall of the agger nasi cell is formed by lacrimal bone, the medial wall of the agger nasi cell is formed by uncinate process. And the anterior wall is formed by the frontal process of the maxilla. The superior portion of the uncinate process forms the medial, posterior and top wall of the agger nasi cells. The superior portion of the uncinate extends into the frontal recess and may insert into lamina papyracea (33.3%), skull base (9.5%), middle turbinate, combination of these (57.2%). The agger nasi cell is the key that unlocks the frontal recess.
Endoscopic training in gastroenterology fellowship: adherence to core curriculum guidelines.
Jirapinyo, Pichamol; Imaeda, Avlin B; Thompson, Christopher C
2015-12-01
The Gastroenterology Core Curriculum and American Society of Gastrointestinal Endoscopy provide guidelines for endoscopic training. Program adherence to these recommendations is unclear. This study aims to assess endoscopic training experience during fellowship. Questionnaire study. The questionnaire was circulated to US fellowship programs, with the assistance of the American Gastroenterological Association. Graduating third-year fellows. Seventy-three fellows returned the questionnaire. Nearly all fellows met the required numbers for esophagoduodenoscopy (98%) and colonoscopy (100%), with fewer meeting requirements for PEG (73%) and non-variceal hemorrhage (75%). The majority of fellows did not meet minimum numbers for variceal banding (40%), esophageal dilation (43%), capsule endoscopy (42%). Fellows rated training in cognitive aspects of endoscopy as 3.86 [1 (inadequate), 5 (excellent)] and reported greatest emphasis on interpreting endoscopic findings and least on virtual colonography. Quality indicators of endoscopy received little emphasis (rating of 3.04; p = 0.00001), with adenoma detection rate being least emphasized. Fifty-six percent of fellows reported having routine endoscopy conferences. Half of the programs have endoscopic simulators, with 15% of fellows being required to use simulation. Following direct hands-on experience, fellows rated external endoscopy courses (64%) as the next most useful experience. Many fellows do not meet required numbers for several endoscopic procedures, and quality indicators receive little emphasis during training. Most programs do not provide simulation training or hold regular endoscopy conferences. Fellowship programs should perform internal audits and make feasible adjustments. Furthermore, it may be time for professional societies to revisit training guidelines.
Fujii, Hiroyuki; Ishii, Eiji; Tochitani, Shinako; Nakaji, So; Hirata, Nobuto; Kusanagi, Hiroshi; Narita, Makoto
2015-01-01
In the expanded indications for endoscopic resection, Japanese guidelines for gastric cancer include differentiated cancers confined to the mucosa with an ulcer <30 mm. We describe a patient with lymph node metastasis after curative endoscopic submucosal dissection (ESD) for a tumor of this indication. The patient was a 70-year-old man with chronic hepatitis C. He underwent ESD for early gastric cancer in May 2010. Pathology revealed a moderately differentiated adenocarcinoma, 22 × 17 mm in size, that was confined to the mucosa with an ulcer. The horizontal and vertical margins were negative for the tumor. We diagnosed thiscase as curative resection of expanded indication and followed this patient with endoscopy, abdominal ultrasonography (AUS) or enhanced computed tomography (CT) approximately every 6 months. After 17 months, lymph node metastasis was detected with AUS and CT and diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy in August 2011. Distal gastrectomy with D2 dissection was carried out in December 2011. Although it is low, the possibility of recurrence should be borne in mind after endoscopic treatment of early gastric cancer, despite its inclusion in the expanded indications for endoscopic resection. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Keklikoglou, Kleoniki; Faulwetter, Sarah; Chatzinikolaou, Eva; Michalakis, Nikitas; Filiopoulou, Irene; Minadakis, Nikos; Panteri, Emmanouela; Perantinos, George; Gougousis, Alexandros; Arvanitidis, Christos
2016-01-01
During recent years, X-ray microtomography (micro-CT) has seen an increasing use in biological research areas, such as functional morphology, taxonomy, evolutionary biology and developmental research. Micro-CT is a technology which uses X-rays to create sub-micron resolution images of external and internal features of specimens. These images can then be rendered in a three-dimensional space and used for qualitative and quantitative 3D analyses. However, the online exploration and dissemination of micro-CT datasets are rarely made available to the public due to their large size and a lack of dedicated online platforms for the interactive manipulation of 3D data. Here, the development of a virtual micro-CT laboratory (Micro-CT vlab ) is described, which can be used by everyone who is interested in digitisation methods and biological collections and aims at making the micro-CT data exploration of natural history specimens freely available over the internet. The Micro-CT vlab offers to the user virtual image galleries of various taxa which can be displayed and downloaded through a web application. With a few clicks, accurate, detailed and three-dimensional models of species can be studied and virtually dissected without destroying the actual specimen. The data and functions of the Micro-CT vlab can be accessed either on a normal computer or through a dedicated version for mobile devices.
Hashimoto, Daniel A; Petrusa, Emil; Phitayakorn, Roy; Valle, Christina; Casey, Brenna; Gee, Denise
2018-03-01
The fundamentals of endoscopic surgery (FES) examination is a national test of knowledge and skill in flexible gastrointestinal endoscopy. The skill portion of the examination involves five tasks that assesses the following skills: scope navigation, loop reduction, mucosal inspection, retroflexion, and targeting. This project aimed to assess the efficacy of a proficiency-based virtual reality (VR) curriculum in preparing residents for the FES skills exam. Experienced (>100 career colonoscopies) and inexperienced endoscopists (<50 career colonoscopies) were recruited to participate. Six VR modules were identified as reflecting the skills tested in the exam. All participants were asked to perform each of the selected modules twice, and median performance was compared between the two groups. Inexperienced endoscopists were subsequently randomized in matched pairs into a repetition (10 repetitions of each task) or proficiency curriculum. After completion of the respective curriculum, FES scores and pass rates were compared to national data and historical institutional control data (endoscopy-rotation training alone). Five experienced endoscopists and twenty-three inexperienced endoscopists participated. Construct valid metrics were identified for six modules and proficiency benchmarks were set at the median performance of experienced endoscopists. FES scores of inexperienced endoscopists in the proficiency group had significantly higher FES scores (530 ± 86) versus historical control (386.7 ± 92.2, p = 0.0003) and higher pass rate (proficiency: 100%, historical control 61.5%, p = 0.01). Trainee engagement in a VR curriculum yields superior FES performance compared to an endoscopy rotation alone. Compared to the 2012-2016 national resident pass rate of 80, 100% of trainees in a proficiency-based curriculum passed the FES manual skills examination.
Negreanu, L; Preda, C M; Ionescu, D; Ferechide, D
2015-01-01
Background. A substantial advance in digestive endoscopy that has been made during the last decade is represented by digital chromoendoscopy, which was developed as a quicker and sometimes better alternative to the gold standard of dye spraying. Fujifilm developed a virtual coloration technique called Flexible spectral Imaging Color Enhancement (FICE). FICE provides a better detection of lesions of "minimal" esophagitis, of dysplasia in Barrett's esophagus and of squamous cell esophageal cancer. The use of FICE resulted in an improvement in the visualization of the early gastric cancer, being less invasive, and time consuming than the classic dye methods. Current evidence does not support FICE for screening purposes in colon cancer but it definitely improves characterization of colonic lesions. Its use in inflammatory bowel disease is still controversial and in video capsule endoscopy is considered a substantial progress. Conclusions. The use of FICE endoscopy in routine clinical practice can increase the diagnostic yield and can provide a better characterization of lesions. Future studies to validate its use, the good choice of channels, and the "perfect indications" and to provide common definitions and classifications are necessary.
Leng, Shuai; Yu, Lifeng; Fletcher, Joel G; McCollough, Cynthia H
2015-08-01
To determine the iodine contrast-to-noise ratio (CNR) for abdominal computed tomography (CT) when using energy domain noise reduction and virtual monoenergetic dual-energy (DE) CT images and to compare the CNR to that attained with single-energy CT at 80, 100, 120, and 140 kV. This HIPAA-compliant study was approved by the institutional review board with waiver of informed consent. A syringe filled with diluted iodine contrast material was placed into 30-, 35-, and 45-cm-wide water phantoms and scanned with a dual-source CT scanner in both DE and single-energy modes with matched scanner output. Virtual monoenergetic images were generated, with energies ranging from 40 to 110 keV in 10-keV steps. A previously developed energy domain noise reduction algorithm was applied to reduce image noise by exploiting information redundancies in the energy domain. Image noise and iodine CNR were calculated. To show the potential clinical benefit of this technique, it was retrospectively applied to a clinical DE CT study of the liver in a 59-year-old male patient by using conventional and iterative reconstruction techniques. Image noise and CNR were compared for virtual monoenergetic images with and without energy domain noise reduction at each virtual monoenergetic energy (in kiloelectron volts) and phantom size by using a paired t test. CNR of virtual monoenergetic images was also compared with that of single-energy images acquired with 80, 100, 120, and 140 kV. Noise reduction of up to 59% (28.7 of 65.7) was achieved for DE virtual monoenergetic images by using an energy domain noise reduction technique. For the commercial virtual monoenergetic images, the maximum iodine CNR was achieved at 70 keV and was 18.6, 16.6, and 10.8 for the 30-, 35-, and 45-cm phantoms. After energy domain noise reduction, maximum iodine CNR was achieved at 40 keV and increased to 30.6, 25.4, and 16.5. These CNRs represented improvement of up to 64% (12.0 of 18.6) with the energy domain noise reduction technique. For single-energy CT at the optimal tube potential, iodine CNR was 29.1 (80 kV), 21.2 (80 kV), and 11.5 (100 kV). For patient images, 39% (24 of 61) noise reduction and 67% (0.74 of 1.10) CNR improvement were observed with the energy domain noise reduction technique when compared with standard filtered back-projection images. Iodine CNR for adult abdominal CT may be maximized with energy domain noise reduction and virtual monoenergetic DE CT. (©) RSNA, 2015.
Gonczi, Lorant; Kurti, Zsuzsanna; Golovics, Petra Anna; Lovasz, Barbara Dorottya; Menyhart, Orsolya; Seres, Anna; Sumegi, Liza Dalma; Gal, Alexander; Ilias, Akos; Janos, Papp; Gecse, Krisztina Barbara; Bessisow, Talat; Afif, Waqqas; Bitton, Alain; Vegh, Zsuzsanna; Lakatos, Peter Laszlo
2018-01-01
In the management of inflammatory bowel diseases, there is considerable variation in quality of care. The aim of this study was to evaluate structural, access/process components and outcome quality indicators in our tertiary referral IBD center. In the first phase, structural/process components were assessed, followed by the second phase of formal evaluation of access and management on a set of consecutive IBD patients with and without active disease (248CD/125UC patients, median age 35/39 years). Structural/process components of our IBD center met the international recommendations. At or around the time of diagnosis usual procedures were full colonoscopy in all patients, with ileocolonoscopy/gastroscopy/CT/MRI in 81.8/45.5/66.1/49.6% of CD patients. A total of 86.7% of CD patients had any follow-up imaging evaluation or endoscopy. The median waiting time for non-emergency endoscopy/CT/MRI was 16/14/22 days. During the observational period patients with flares (CD/UC:50.6/54.6%) were seen by specialist at the IBD clinic within a median of 1day with same day laboratory assessment, abdominal US, CT scan/surgical consult and change in therapy if needed. Surgery and hospitalization rates were 20.1/1.4% and 17.3/3.2% of CD/UC patients. Our results highlight that structural components and processes applied in our center are in line with international recommendations, including an open clinic concept and fast track access to specialist consultation, endoscopy and imaging. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Ethmoidectomy combined with superior meatus enlargement increases olfactory airflow
Kondo, Kenji; Nomura, Tsutomu; Yamasoba, Tatsuya
2017-01-01
Objectives The relationship between a particular surgical technique in endoscopic sinus surgery (ESS) and airflow changes in the post‐operative olfactory region has not been assessed. The present study aimed to compare olfactory airflow after ESS between conventional ethmoidectomy and ethmoidectomy with superior meatus enlargement, using virtual ESS and computational fluid dynamics (CFD) analysis. Study Design Prospective computational study. Materials and Methods Nasal computed tomography images of four adult subjects were used to generate models of the nasal airway. The original preoperative model was digitally edited as virtual ESS by performing uncinectomy, ethmoidectomy, antrostomy, and frontal sinusotomy. The following two post‐operative models were prepared: conventional ethmoidectomy with normal superior meatus (ESS model) and ethmoidectomy with superior meatus enlargement (ESS‐SM model). The calculated three‐dimensional nasal geometries were confirmed using virtual endoscopy to ensure that they corresponded to the post‐operative anatomy observed in the clinical setting. Steady‐state, laminar, inspiratory airflow was simulated, and the velocity, streamline, and mass flow rate in the olfactory region were compared among the preoperative and two postoperative models. Results The mean velocity in the olfactory region, number of streamlines bound to the olfactory region, and mass flow rate were higher in the ESS‐SM model than in the other models. Conclusion We successfully used an innovative approach involving virtual ESS, virtual endoscopy, and CFD to assess postoperative outcomes after ESS. It is hypothesized that the increased airflow to the olfactory fossa achieved with ESS‐SM may lead to improved olfactory function; however, further studies are required. Level of Evidence NA. PMID:28894833
CT imaging of the internal human ear: Test of a high resolution scanner
NASA Astrophysics Data System (ADS)
Bettuzzi, M.; Brancaccio, R.; Morigi, M. P.; Gallo, A.; Strolin, S.; Casali, F.; Lamanna, Ernesto; Ariù, Marilù
2011-08-01
During the course of 2009, in the framework of a project supported by the National Institute of Nuclear Physics, a number of tests were carried out at the Department of Physics of the University of Bologna in order to achieve a good quality CT scan of the internal human ear. The work was carried out in collaboration with the local “S. Orsola” Hospital in Bologna and a company (CEFLA) already involved in the production and commercialization of a CT scanner dedicated to dentistry. A laboratory scanner with a simple concept detector (CCD camera-lens-mirror-scintillator) was used to see to what extent it was possible to enhance the quality of a conventional CT scanner when examining the internal human ear. To test the system, some conventional measurements were made, such as the spatial resolution calculation with the MTF and dynamic range evaluation. Different scintillators were compared to select the most suitable for the purpose. With 0.5 mm thick structured cesium iodide and a field of view of 120×120 mm2, a spatial resolution of 6.5l p/mm at 5% MTF was obtained. The CT of a pair of human head phantoms was performed at an energy of 120 kVp. The first phantom was a rough representation of the human head shape, with soft tissue made of coarse slabs of Lucite. Some inserts, like small aluminum cylinders and cubes, with 1 mm diameter drilled holes, were used to simulate the channels that one finds inside the human inner ear. The second phantom is a plastic PVC fused head with a real human cranium inside. The bones in the cranium are well conserved and the inner ear features, such as the cochlea and semicircular channels, are clearly detectable. After a number of CT tests we obtained good results as far as structural representation and channel detection are concerned. Some images of the 3D rendering of the CT volume are shown below. The doctors of the local hospital who followed our experimentation expressed their satisfaction. The CT was compared to a virtual endoscopy and judged particularly useful for clinical pre-surgery diagnostics. The experimentation proceeds with a faster scanner now under development in our laboratories. We believe this work could be of a certain interest for the medical imaging world.
Development and comparison of projection and image space 3D nodule insertion techniques
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan
2016-04-01
This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.
Wang, Peng; Yin, Lingshu; Zhang, Yawei; Kirk, Maura; Song, Gang; Ahn, Peter H; Lin, Alexander; Gee, James; Dolney, Derek; Solberg, Timothy D; Maughan, Richard; McDonough, James; Teo, Boon-Keng Kevin
2016-03-08
The aim of this work is to demonstrate the feasibility of using water-equivalent thickness (WET) and virtual proton depth radiographs (PDRs) of intensity corrected cone-beam computed tomography (CBCT) to detect anatomical change and patient setup error to trigger adaptive head and neck proton therapy. The planning CT (pCT) and linear accelerator (linac) equipped CBCTs acquired weekly during treatment of a head and neck patient were used in this study. Deformable image registration (DIR) was used to register each CBCT with the pCT and map Hounsfield units (HUs) from the planning CT (pCT) onto the daily CBCT. The deformed pCT is referred as the corrected CBCT (cCBCT). Two dimensional virtual lateral PDRs were generated using a ray-tracing technique to project the cumulative WET from a virtual source through the cCBCT and the pCT onto a virtual plane. The PDRs were used to identify anatomic regions with large variations in the proton range between the cCBCT and pCT using a threshold of 3 mm relative difference of WET and 3 mm search radius criteria. The relationship between PDR differences and dose distribution is established. Due to weight change and tumor response during treatment, large variations in WETs were observed in the relative PDRs which corresponded spatially with an increase in the number of failing points within the GTV, especially in the pharynx area. Failing points were also evident near the posterior neck due to setup variations. Differences in PDRs correlated spatially to differences in the distal dose distribution in the beam's eye view. Virtual PDRs generated from volumetric data, such as pCTs or CBCTs, are potentially a useful quantitative tool in proton therapy. PDRs and WET analysis may be used to detect anatomical change from baseline during treatment and trigger further analysis in adaptive proton therapy.
Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao
2007-01-01
Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination. PMID:17465517
Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao
2007-04-21
Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination.
Computerized lateral endoscopic approach to invertebral bodies
NASA Astrophysics Data System (ADS)
Abbasi, Hamid R.; Hariri, Sanaz; Kim, Daniel; Shahidi, Ramin; Steinberg, Gary
2001-05-01
Spinal surgery is often necessary to ease back pain symptoms. Neuronavigation (NN) allows the surgeon to localize the position of his instruments in 3D using pre- operative CT scans registered to intra-operative marker positions in cranial surgeries. However, this tool is unavailable in spinal surgeries for a variety of reasons. For example, because of the spine's many degrees of freedom and flexibility, the geometric relationship of the skin to the internal spinal anatomy is not fixed. Guided by the currently available imperfect 2D images, it is difficult for the surgeon to correct a patient's spinal anomaly; thus surgical relief of back pain is often only temporary. The Image Guidance Laborator's (IGL) goal is to combine the direct optical control of traditional endoscopy with the 3D orientation of NN. This powerful tool requires registration of the patient's anatomy to the surgical navigation system using internal landmarks rather than skin markers. Pre- operative CT scans matched with intraoperative fluoroscopic images can overcome the problem of spinal movement in NN registration. The combination of endoscopy with fluoroscopic registration of vertebral bodies in a NN system provides a 3D intra-operative navigational system for spinal neurosurgery to visualize the internal surgical environment from any orientation in real time. The accuracy of this system integration is being evaluated by assessing the success of nucleotomies and marker implantations guided by NN-registered endoscopy.
Dual-Energy CT: New Horizon in Medical Imaging
Goo, Jin Mo
2017-01-01
Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector. PMID:28670151
Raque, Jessica; Goble, Adam; Jones, Veronica M; Waldman, Lindsey E; Sutton, Erica
2015-07-01
With the introduction of Fundamentals of Endoscopic Surgery, training methods in flexible endoscopy are being augmented with simulation-based curricula. The investment for virtual reality simulators warrants further research into its training advantage. Trainees were randomized into bedside or simulator training groups (BED vs SIM). SIM participated in a proficiency-based virtual reality curriculum. Trainees' endoscopic skills were rated using the Global Assessment of Gastrointestinal Endoscopic Skills (GAGES) in the patient care setting. The number of cases to reach 90 per cent of the maximum GAGES score and calculated costs of training were compared. Nineteen residents participated in the study. There was no difference in the average number of cases required to achieve 90 per cent of the maximum GAGES score for esophagogastroduodenoscopy, 13 (SIM) versus11 (BED) (P = 0.63), or colonoscopy 21 (SIM) versus 4 (BED) (P = 0.34). The average per case cost of training for esophagogastroduodenoscopy was $35.98 (SIM) versus $39.71 (BED) (P = 0.50), not including the depreciation costs associated with the simulator ($715.00 per resident over six years). Use of a simulator appeared to increase the cost of training without accelerating the learning curve or decreasing faculty time spent in instruction. The importance of simulation in endoscopy training will be predicated on more cost-effective simulators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Z; Greskovich, J; Xia, P
Purpose: To generate virtual phantoms with clinically relevant deformation and use them to objectively evaluate geometric and dosimetric uncertainties of deformable image registration (DIR) algorithms. Methods: Ten lung cancer patients undergoing adaptive 3DCRT planning were selected. For each patient, a pair of planning CT (pCT) and replanning CT (rCT) were used as the basis for virtual phantom generation. Manually adjusted meshes were created for selected ROIs (e.g. PTV, lungs, spinal cord, esophagus, and heart) on pCT and rCT. The mesh vertices were input into a thin-plate spline algorithm to generate a reference displacement vector field (DVF). The reference DVF wasmore » used to deform pCT to generate a simulated replanning CT (srCT) that was closely matched to rCT. Three DIR algorithms (Demons, B-Spline, and intensity-based) were applied to these ten virtual phantoms. The images, ROIs, and doses were mapped from pCT to srCT using the DVFs computed by these three DIRs and compared to those mapped using the reference DVF. Results: The average Dice coefficients for selected ROIs were from 0.85 to 0.96 for Demons, from 0.86 to 0.97 for intensity-based, and from 0.76 to 0.95 for B-Spline. The average Hausdorff distances for selected ROIs were from 2.2 to 5.4 mm for Demons, from 2.3 to 6.8 mm for intensity-based, and from 2.4 to 11.4 mm for B-Spline. The average absolute dose errors for selected ROIs were from 0.2 to 0.6 Gy for Demons, from 0.1 to 0.5 Gy for intensity-based, and from 0.5 to 1.5 Gy for B-Spline. Conclusion: Virtual phantoms were modeled after patients with lung cancer and were clinically relevant for adaptive radiotherapy treatment replanning. Virtual phantoms with known DVFs serve as references and can provide a fair comparison when evaluating different DIRs. Demons and intensity-based DIRs were shown to have smaller geometric and dosimetric uncertainties than B-Spline. Z Shen: None; K Bzdusek: an employee of Philips Healthcare; J Greskovich: None; P Xia: received research grants from Philips Healthcare and Siemens Healthcare.« less
Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.
Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert
2006-11-01
Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.
Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko
2018-03-21
To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Hybrid rendering of the chest and virtual bronchoscopy [corrected].
Seemann, M D; Seemann, O; Luboldt, W; Gebicke, K; Prime, G; Claussen, C D
2000-10-30
Thin-section spiral computed tomography was used to acquire the volume data sets of the thorax. The tracheobronchial system and pathological changes of the chest were visualized using a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures, thus producing a hybrid rendering. The hybrid rendering technique exploit the advantages of both rendering methods and enable virtual bronchoscopic examinations using different representation models. Virtual bronchoscopic examinations with a transparent color-coded shaded-surface model enables the simultaneous visualization of both the airways and the adjacent structures behind of the tracheobronchial wall and therefore, offers a practical alternative to fiberoptic bronchoscopy. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images.
Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki
2018-05-01
To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Material Separation Using Dual-Energy CT: Current and Emerging Applications.
Patino, Manuel; Prochowski, Andrea; Agrawal, Mukta D; Simeone, Frank J; Gupta, Rajiv; Hahn, Peter F; Sahani, Dushyant V
2016-01-01
Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.
Paech, Daniel; Giesel, Frederik L; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara
2017-05-01
The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n 1 = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n 2 = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n 3 = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. • Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. • Radiological education integrated into gross anatomy is highly appreciated by medical students. • Simultaneous physical and virtual dissection provide unique conditions to study anatomy.
Controversies in colorectal cancer screening.
Pox, Christian P
2014-01-01
Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.
Kobayashi, Hajime; Ohkubo, Masaki; Narita, Akihiro; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Sone, Shusuke
2017-01-01
Objective: We propose the application of virtual nodules to evaluate the performance of computer-aided detection (CAD) of lung nodules in cancer screening using low-dose CT. Methods: The virtual nodules were generated based on the spatial resolution measured for a CT system used in an institution providing cancer screening and were fused into clinical lung images obtained at that institution, allowing site specificity. First, we validated virtual nodules as an alternative to artificial nodules inserted into a phantom. In addition, we compared the results of CAD analysis between the real nodules (n = 6) and the corresponding virtual nodules. Subsequently, virtual nodules of various sizes and contrasts between nodule density and background density (ΔCT) were inserted into clinical images (n = 10) and submitted for CAD analysis. Results: In the validation study, 46 of 48 virtual nodules had the same CAD results as artificial nodules (kappa coefficient = 0.913). Real nodules and the corresponding virtual nodules showed the same CAD results. The detection limits of the tested CAD system were determined in terms of size and density of peripheral lung nodules; we demonstrated that a nodule with a 5-mm diameter was detected when the nodule had a ΔCT > 220 HU. Conclusion: Virtual nodules are effective in evaluating CAD performance using site-specific scan/reconstruction conditions. Advances in knowledge: Virtual nodules can be an effective means of evaluating site-specific CAD performance. The methodology for guiding the detection limit for nodule size/density might be a useful evaluation strategy. PMID:27897029
VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients.
Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Long, Daniel J; Bolch, Wesley E; Liu, Bob; Xu, X George
2015-07-21
This paper describes the development and testing of VirtualDose--a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the 'software as a service (SaaS)' delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose's functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT-two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.
Necrotizing infection of the heart.
Ballard, David H; Pennington, George Patton; Pennington, George P; Johnson, Joe; Bhalla, Sanjeev; Raptis, Constantine
2018-02-06
A case of necrotizing infection of the heart is presented. A 70-year-old woman presented with vague chest and abdominal pain. CT of the abdomen and pelvis was initially obtained, which demonstrated gas in the myocardium of the left ventricle. Subsequent chest CT, endoscopy, and abdominal surgical exploration did not reveal perforated viscus or diaphragm compromise. At median sternotomy, the inferior wall of the heart was found to be necrotic. Culture of the excised tissue grew E. coli. The patient expired shortly after surgical exploration. Copyright © 2018 Elsevier Inc. All rights reserved.
77 FR 45342 - Maxfield and Oberton Holdings, LLC; Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-31
..., including x-rays and monitoring for infection and internal damage. 27. Since March 2009 to approximately... had to undergo x-rays, CT scans, endoscopy, and an appendectomy to remove them. The girl's father had... attraction of the magnets to the metal equipment used to retrieve the magnets. 22. Children who undergo...
Faulwetter, Sarah; Chatzinikolaou, Eva; Michalakis, Nikitas; Filiopoulou, Irene; Minadakis, Nikos; Panteri, Emmanouela; Perantinos, George; Gougousis, Alexandros; Arvanitidis, Christos
2016-01-01
Abstract Background During recent years, X-ray microtomography (micro-CT) has seen an increasing use in biological research areas, such as functional morphology, taxonomy, evolutionary biology and developmental research. Micro-CT is a technology which uses X-rays to create sub-micron resolution images of external and internal features of specimens. These images can then be rendered in a three-dimensional space and used for qualitative and quantitative 3D analyses. However, the online exploration and dissemination of micro-CT datasets are rarely made available to the public due to their large size and a lack of dedicated online platforms for the interactive manipulation of 3D data. Here, the development of a virtual micro-CT laboratory (Micro-CTvlab) is described, which can be used by everyone who is interested in digitisation methods and biological collections and aims at making the micro-CT data exploration of natural history specimens freely available over the internet. New information The Micro-CTvlab offers to the user virtual image galleries of various taxa which can be displayed and downloaded through a web application. With a few clicks, accurate, detailed and three-dimensional models of species can be studied and virtually dissected without destroying the actual specimen. The data and functions of the Micro-CTvlab can be accessed either on a normal computer or through a dedicated version for mobile devices. PMID:27956848
A model for flexible tools used in minimally invasive medical virtual environments.
Soler, Francisco; Luzon, M Victoria; Pop, Serban R; Hughes, Chris J; John, Nigel W; Torres, Juan Carlos
2011-01-01
Within the limits of current technology, many applications of a virtual environment will trade-off accuracy for speed. This is not an acceptable compromise in a medical training application where both are essential. Efficient algorithms must therefore be developed. The purpose of this project is the development and validation of a novel physics-based real time tool manipulation model, which is easy to integrate into any medical virtual environment that requires support for the insertion of long flexible tools into complex geometries. This encompasses medical specialities such as vascular interventional radiology, endoscopy, and laparoscopy, where training, prototyping of new instruments/tools and mission rehearsal can all be facilitated by using an immersive medical virtual environment. Our model recognises and uses accurately patient specific data and adapts to the geometrical complexity of the vessel in real time.
Soft 3D-Printed Phantom of the Human Kidney with Collecting System.
Adams, Fabian; Qiu, Tian; Mark, Andrew; Fritz, Benjamin; Kramer, Lena; Schlager, Daniel; Wetterauer, Ulrich; Miernik, Arkadiusz; Fischer, Peer
2017-04-01
Organ models are used for planning and simulation of operations, developing new surgical instruments, and training purposes. There is a substantial demand for in vitro organ phantoms, especially in urological surgery. Animal models and existing simulator systems poorly mimic the detailed morphology and the physical properties of human organs. In this paper, we report a novel fabrication process to make a human kidney phantom with realistic anatomical structures and physical properties. The detailed anatomical structure was directly acquired from high resolution CT data sets of human cadaveric kidneys. The soft phantoms were constructed using a novel technique that combines 3D wax printing and polymer molding. Anatomical details and material properties of the phantoms were validated in detail by CT scan, ultrasound, and endoscopy. CT reconstruction, ultrasound examination, and endoscopy showed that the designed phantom mimics a real kidney's detailed anatomy and correctly corresponds to the targeted human cadaver's upper urinary tract. Soft materials with a tensile modulus of 0.8-1.5 MPa as well as biocompatible hydrogels were used to mimic human kidney tissues. We developed a method of constructing 3D organ models from medical imaging data using a 3D wax printing and molding process. This method is cost-effective means for obtaining a reproducible and robust model suitable for surgical simulation and training purposes.
VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients
NASA Astrophysics Data System (ADS)
Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George
2015-07-01
This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.
Integrated bronchoscopic video tracking and 3D CT registration for virtual bronchoscopy
NASA Astrophysics Data System (ADS)
Higgins, William E.; Helferty, James P.; Padfield, Dirk R.
2003-05-01
Lung cancer assessment involves an initial evaluation of 3D CT image data followed by interventional bronchoscopy. The physician, with only a mental image inferred from the 3D CT data, must guide the bronchoscope through the bronchial tree to sites of interest. Unfortunately, this procedure depends heavily on the physician's ability to mentally reconstruct the 3D position of the bronchoscope within the airways. In order to assist physicians in performing biopsies of interest, we have developed a method that integrates live bronchoscopic video tracking and 3D CT registration. The proposed method is integrated into a system we have been devising for virtual-bronchoscopic analysis and guidance for lung-cancer assessment. Previously, the system relied on a method that only used registration of the live bronchoscopic video to corresponding virtual endoluminal views derived from the 3D CT data. This procedure only performs the registration at manually selected sites; it does not draw upon the motion information inherent in the bronchoscopic video. Further, the registration procedure is slow. The proposed method has the following advantages: (1) it tracks the 3D motion of the bronchoscope using the bronchoscopic video; (2) it uses the tracked 3D trajectory of the bronchoscope to assist in locating sites in the 3D CT "virtual world" to perform the registration. In addition, the method incorporates techniques to: (1) detect and exclude corrupted video frames (to help make the video tracking more robust); (2) accelerate the computation of the many 3D virtual endoluminal renderings (thus, speeding up the registration process). We have tested the integrated tracking-registration method on a human airway-tree phantom and on real human data.
Efficiency of endoscopy units can be improved with use of discrete event simulation modeling.
Sauer, Bryan G; Singh, Kanwar P; Wagner, Barry L; Vanden Hoek, Matthew S; Twilley, Katherine; Cohn, Steven M; Shami, Vanessa M; Wang, Andrew Y
2016-11-01
Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience.
Efficiency of endoscopy units can be improved with use of discrete event simulation modeling
Sauer, Bryan G.; Singh, Kanwar P.; Wagner, Barry L.; Vanden Hoek, Matthew S.; Twilley, Katherine; Cohn, Steven M.; Shami, Vanessa M.; Wang, Andrew Y.
2016-01-01
Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience. PMID:27853739
Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J
2017-07-01
Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.
Tsukiyama, Atsushi; Tagami, Takashi; Kim, Shiei; Yokota, Hiroyuki
2014-01-01
Computed tomography (CT) is useful for evaluating esophageal foreign bodies and detecting perforation. However, when evaluation is difficult owing to the previous use of barium as a contrast medium, 3-dimensional CT may facilitate accurate diagnosis. A 49-year-old man was transferred to our hospital with the diagnosis of esophageal perforation. Because barium had been used as a contrast medium for an esophagram performed at a previous hospital, horizontal CT and esophageal endoscopy could not be able to identify the foreign body or characterize the lesion. However, 3-dimensional CT clearly revealed an L-shaped foreign body and its anatomical relationships in the mediastinum. Accordingly, we removed the foreign body using an upper gastrointestinal endoscope. The foreign body was the premaxillary bone of a sea bream. The patient was discharged without complications.
Test of 3D CT reconstructions by EM + TV algorithm from undersampled data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evseev, Ivan; Ahmann, Francielle; Silva, Hamilton P. da
2013-05-06
Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry withmore » alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.« less
Computer-assisted virtual autopsy using surgical navigation techniques.
Ebert, Lars Christian; Ruder, Thomas D; Martinez, Rosa Maria; Flach, Patricia M; Schweitzer, Wolf; Thali, Michael J; Ampanozi, Garyfalia
2015-01-01
OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.
[A Case of Gastro-Gastric Intussusception Secondary to Primary Gastric Lymphoma].
Jo, Hyeong Ho; Kang, Sun Mi; Kim, Si Hye; Ra, Moni; Park, Byeong Kyu; Kwon, Joong Goo; Kim, Eun Young; Jung, Jin Tae; Kim, Ho Gak; Ryoo, Hun Mo; Kang, Ung Rae
2016-07-25
In adults, most intussusceptions develop from a lesion, usually a benign or malignant neoplasm, and can occur at any site in the gastrointestinal tract. Intussusception in the proximal gastrointestinal tract is uncommon, and gastro-gastric intussusception is extremely rare. We present a case of gastro-gastric intussusception secondary to a primary gastric lymphoma. An 82-year-old female patient presented with acute onset chest pain and vomiting. Abdominal CT revealed a gastro-gastric intussusception. We performed upper gastrointestinal endoscopy, revealing a large gastric mass invaginated into the gastric lumen and distorting the distal stomach. Uncomplicated gastric reposition was achieved with endoscopy of the distal stomach. Histological evaluation of the gastric mass revealed a diffuse large B cell lymphoma that was treated with chemotherapy.
Flat colon polyps: what should radiologists know?
Ignjatovic, A; Burling, D; Ilangovan, R; Clark, S K; Taylor, S A; East, J E; Saunders, B P
2010-12-01
With the recent publication of international computed tomography (CT) colonography standards, which aim to improve quality of examinations, this review informs radiologists about the significance of flat polyps (adenomas and hyperplastic polyps) in colorectal cancer pathways. We describe flat polyp classification systems and propose how flat polyps should be reported to ensure patient management strategies are based on polyp morphology as well as size. Indeed, consistency when describing flat polyps is of increasing importance given the strengthening links between CT colonography and endoscopy. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Automated flight path planning for virtual endoscopy.
Paik, D S; Beaulieu, C F; Jeffrey, R B; Rubin, G D; Napel, S
1998-05-01
In this paper, a novel technique for rapid and automatic computation of flight paths for guiding virtual endoscopic exploration of three-dimensional medical images is described. While manually planning flight paths is a tedious and time consuming task, our algorithm is automated and fast. Our method for positioning the virtual camera is based on the medial axis transform but is much more computationally efficient. By iteratively correcting a path toward the medial axis, the necessity of evaluating simple point criteria during morphological thinning is eliminated. The virtual camera is also oriented in a stable viewing direction, avoiding sudden twists and turns. We tested our algorithm on volumetric data sets of eight colons, one aorta and one bronchial tree. The algorithm computed the flight paths in several minutes per volume on an inexpensive workstation with minimal computation time added for multiple paths through branching structures (10%-13% per extra path). The results of our algorithm are smooth, centralized paths that aid in the task of navigation in virtual endoscopic exploration of three-dimensional medical images.
[Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].
Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D
2000-01-01
Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.
Application of Virtual Navigation with Multimodality Image Fusion in Foramen Ovale Cannulation.
Qiu, Xixiong; Liu, Weizong; Zhang, Mingdong; Lin, Hengzhou; Zhou, Shoujun; Lei, Yi; Xia, Jun
2017-11-01
Idiopathic trigeminal neuralgia (ITN) can be effectively treated with radiofrequency thermocoagulation. However, this procedure requires cannulation of the foramen ovale, and conventional cannulation methods are associated with high failure rates. Multimodality imaging can improve the accuracy of cannulation because each imaging method can compensate for the drawbacks of the other. We aim to determine the feasibility and accuracy of percutaneous foramen ovale cannulation under the guidance of virtual navigation with multimodality image fusion in a self-designed anatomical model of human cadaveric heads. Five cadaveric head specimens were investigated in this study. Spiral computed tomography (CT) scanning clearly displayed the foramen ovale in all five specimens (10 foramina), which could not be visualized using two-dimensional ultrasound alone. The ultrasound and spiral CT images were fused, and percutaneous cannulation of the foramen ovale was performed under virtual navigation. After this, spiral CT scanning was immediately repeated to confirm the accuracy of the cannulation. Postprocedural spiral CT confirmed that the ultrasound and CT images had been successfully fused for all 10 foramina, which were accurately and successfully cannulated. The success rates of both image fusion and cannulation were 100%. Virtual navigation with multimodality image fusion can substantially facilitate foramen ovale cannulation and is worthy of clinical application. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Darras, Kathryn E; de Bruin, Anique B H; Nicolaou, Savvas; Dahlström, Nils; Persson, Anders; van Merriënboer, Jeroen; Forster, Bruce B
2018-03-23
Educators must select the best tools to teach anatomy to future physicians and traditionally, cadavers have always been considered the "gold standard" simulator for living anatomy. However, new advances in technology and radiology have created new teaching tools, such as virtual dissection, which provide students with new learning opportunities. Virtual dissection is a novel way of studying human anatomy through patient computed tomography (CT) scans. Through touchscreen technology, students can work together in groups to "virtually dissect" the CT scans to better understand complex anatomic relationships. This article presents the anatomic and pedagogic limitations of cadaveric dissection and explains what virtual dissection is and how this new technology may be used to overcome these limitations.
NASA Astrophysics Data System (ADS)
Ayeni, Tina A.; Holmes, David R., III; Robb, Richard A.
2001-05-01
Kawasaki Disease is an inflammatory illness of young children that can seriously affect the cardiovascular system. The disease may cause coronary artery aneurysms, a thinning and dilation of the arterial wall when the wall is weakened by disease. Such aneurysms significantly increase the risk of rupture of the arterial wall, an event from which few patients survive. Due to the largely asymptotic nature of coronary aneurysms, diagnosis must be timely and accurate in order for treatment to be effective. Currently, aneurysms are detected primarily using X-ray angiography, MRI, and CT images. Increased insight into the disease and its effects on the arterial wall can be gained by multi-dimensional computerized visualization and quantitative analysis of diagnostic images made possible by the techniques of intravascular imaging and virtual endoscopy. Intravascular ultrasound images (IVUS) of a coronary artery exhibiting aneurysms were acquired from a patient with Kawasaki Disease. The disease is characterized by low luminescent in the IVUS images. Image segmentation of the abnormal, prominent anechoic regions branching from the lumen and originating within other layers of the arterial wall was performed and each region defined as a separate object. An object segmentation map was generated and used in perspective rendering of the original image volume set at successive locations along the length of the arterial segment, producing a 'fly-through' of the interior of the artery. The diseased region (aneurysm) of the wall was well defined by the differences in luminal size and by differences in appearance of the arterial wall shape observed during virtual angioscopic fly-throughs. Erosions of the endovascular surface caused pronounced horizontal and vertical ballooning of the lumen. Minute cracks within the unaffected luminal areas revealed possible early development of an aneurysm on the contralateral wall, originating in the medial section of the artery and spreading outward toward the lumen.
Finck, Marlène; Ponce, Frédérique; Guilbaud, Laurent; Chervier, Cindy; Floch, Franck; Cadoré, Jean-Luc; Chuzel, Thomas; Hugonnard, Marine
2015-02-01
There are no evidence-based guidelines as to whether computed tomography (CT) or endoscopy should be selected as the first-line procedure when a nasal tumor is suspected in a dog or a cat and only one examination can be performed. Computed tomography and rhinoscopic features of 17 dogs and 5 cats with a histopathologically or cytologically confirmed nasal tumor were retrospectively reviewed. The level of suspicion for nasal neoplasia after CT and/or rhinoscopy was compared to the definitive diagnosis. Twelve animals underwent CT, 14 underwent rhinoscopy, and 4 both examinations. Of the 12 CT examinations performed, 11 (92%) resulted in the conclusion that a nasal tumor was the most likely diagnosis compared with 9/14 (64%) for rhinoscopies. Computed tomography appeared to be more reliable than rhinoscopy for detecting nasal tumors and should therefore be considered as the first-line procedure.
Finck, Marlène; Ponce, Frédérique; Guilbaud, Laurent; Chervier, Cindy; Floch, Franck; Cadoré, Jean-Luc; Chuzel, Thomas; Hugonnard, Marine
2015-01-01
There are no evidence-based guidelines as to whether computed tomography (CT) or endoscopy should be selected as the first-line procedure when a nasal tumor is suspected in a dog or a cat and only one examination can be performed. Computed tomography and rhinoscopic features of 17 dogs and 5 cats with a histopathologically or cytologically confirmed nasal tumor were retrospectively reviewed. The level of suspicion for nasal neoplasia after CT and/or rhinoscopy was compared to the definitive diagnosis. Twelve animals underwent CT, 14 underwent rhinoscopy, and 4 both examinations. Of the 12 CT examinations performed, 11 (92%) resulted in the conclusion that a nasal tumor was the most likely diagnosis compared with 9/14 (64%) for rhinoscopies. Computed tomography appeared to be more reliable than rhinoscopy for detecting nasal tumors and should therefore be considered as the first-line procedure. PMID:25694669
Idiopathic Chronic Parotitis: Imaging Findings and Sialendoscopic Response.
Heineman, Thomas E; Kacker, Ashutosh; Kutler, David I
2015-01-01
The purpose of this study was to correlate imaging and sialendoscopic findings to therapeutic response in patients with idiopathic chronic parotitis. We retrospectively reviewed 122 consecutive sialendoscopies performed in an academic medical center by two surgeons between 2008 and 2013. Forty-one (34%) and 54 (44%) patients were excluded on the basis of having parotid or submandibular sialolith, respectively. Nineteen cases were included in the study with idiopathic chronic parotitis. There was a median follow-up of 5 months. Computed tomography (CT) imaging had a sensitivity and specificity of 80.0 and 71.4%, respectively, for predicting abnormal findings on sialendoscopy, while magnetic resonance imaging (MRI) had 100% accuracy in a small set of cases. In glands with noticeable pathology present on preoperative imaging or sialendoscopy, 11 out of 12 glands (92%) treated experienced symptomatic improvement, while 3 out of 7 glands (43%) without pathology on imaging or endoscopy experienced symptomatic improvement (p = 0.038). Sialendoscopy for the treatment of idiopathic chronic parotid disease can improve pain and swelling with a higher frequency of success in patients with abnormalities noted on endoscopy. CT and MRI have a moderate degree of accuracy in predicting which patients will benefit from therapeutic sialendoscopy. © 2015 S. Karger AG, Basel.
Qian, Xiaohua; Hecht, Jonathan L
2003-01-01
To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.
Direct Visuo-Haptic 4D Volume Rendering Using Respiratory Motion Models.
Fortmeier, Dirk; Wilms, Matthias; Mastmeyer, Andre; Handels, Heinz
2015-01-01
This article presents methods for direct visuo-haptic 4D volume rendering of virtual patient models under respiratory motion. Breathing models are computed based on patient-specific 4D CT image data sequences. Virtual patient models are visualized in real-time by ray casting based rendering of a reference CT image warped by a time-variant displacement field, which is computed using the motion models at run-time. Furthermore, haptic interaction with the animated virtual patient models is provided by using the displacements computed at high rendering rates to translate the position of the haptic device into the space of the reference CT image. This concept is applied to virtual palpation and the haptic simulation of insertion of a virtual bendable needle. To this aim, different motion models that are applicable in real-time are presented and the methods are integrated into a needle puncture training simulation framework, which can be used for simulated biopsy or vessel puncture in the liver. To confirm real-time applicability, a performance analysis of the resulting framework is given. It is shown that the presented methods achieve mean update rates around 2,000 Hz for haptic simulation and interactive frame rates for volume rendering and thus are well suited for visuo-haptic rendering of virtual patients under respiratory motion.
ERIC Educational Resources Information Center
Mroz, Aurore
2015-01-01
This article presents a process-oriented mixed-method study, focusing on the emergence of second language (L2) critical thinking (CT) skills in the collaborative discourse produced by a focal group of five college-level students of French working in a virtual language learning environment (the VLLE Cinet Second Life). Levels of CT ability were…
Hematemesis: Unusual presentation of isolated gastric tuberculosis.
Nasa, Mukesh; Kumar, Arvind; Phadke, Aniruddha; Sawant, Prabha
2016-01-01
A 25-year-old male presented with hematemesis, epigastric pain, and melena. He had dyspepsia with significant weight loss for 3 months period. On clinical examination, he was pale with no organomegaly or lymphadenopathy. The X-ray chest was normal, and ultrasound abdomen was normal. Upper GI endoscopy revealed nodularity and ulceration along proximal part of lesser curvature of the stomach. CT scan abdomen showed thickening of lesser curvature just below gastro-esophageal junction. The biopsies were negative for malignancy. Repeat upper GI endoscopy showed a nonhealing ulcer, on repeat well biopsies taken from the base of ulcer primary gastric tuberculosis was diagnosed. It showed many epithelioid cell granulomas and multinucleated giant cells with caseous necrosis on histology. Acid-fast bacilli on Zeil Neelsen staining and TB PCR were positive for Mycobacterium tuberculosis. He was put on four-drug anti-tuberculous treatment. On follow-up, the patient gradually improved and regained weight. Repeat upper GI endoscopy done after 8 weeks showed healing of the ulcer with decrease in nodularity. Copyright © 2015 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
Nishimura, Junya; Kubo, Naoshi; Lee, Tomohiro; Shinto, Osamu; Sakurai, Katsunobu; Toyokawa, Takahiro; Tanaka, Hiroaki; Muguruma, Kazuya; Shibutani, Masatsune; Yamazoe, Sadaaki; Nagahara, Hisashi; Kimura, Kenjiro; Amano, Ryosuke; Ohtani, Hiroshi; Yashiro, Masakazu; Maeda, Kiyoshi; Ohira, Masaichi; Hirakawa, Kosei
2013-11-01
The patient was a 68-year-old man who complained of hoarseness and dyspnea. Upper gastrointestinal endoscopy revealed a type 3 tumor located in the middle thoracic esophagus at 30 cm from the incisor tooth that involved one-fourth of the circumference of the esophagus. Histopathological examination revealed moderately differentiated squamous cell carcinoma. Chest computed tomography( CT) revealed severe tracheal stenosis due to compression by a metastatic lymph node along the left recurrent laryngeal nerve. The patient was diagnosed as having cT4( 106recL-trachea), N2( 101L, 106recL, 106recR), M0, Stage IVa unresectable esophageal carcinoma. After insertion of a tracheal stent tube( spiral Z stent: diameter, 18 mm; length, 80 mm) to improve dyspnea, combination chemotherapy with 5-fluorouracil( 5-FU) plus nedaplatin was administered. Subsequent CT and endoscopy showed that the main tumor and the metastatic lymph node had significantly reduced in size and that complete response (CR) had been achieved. Thirty months after the initial treatment, the patient showed no sign of disease recurrence, after completion of 19 cycles of chemotherapy. The patient did not experience any severe adverse events. We report a case of a patient with locally advanced squamous cell carcinoma of the esophagus successfully treated with 5-FU/nedaplatin combination chemotherapy following tracheal stent tube placement.
Larsson, Emanuel; Martin, Sabine; Lazzarini, Marcio; Tromba, Giuliana; Missbach-Guentner, Jeannine; Pinkert-Leetsch, Diana; Katschinski, Dörthe M.; Alves, Frauke
2017-01-01
The small size of the adult and developing mouse heart poses a great challenge for imaging in preclinical research. The aim of the study was to establish a phosphotungstic acid (PTA) ex-vivo staining approach that efficiently enhances the x-ray attenuation of soft-tissue to allow high resolution 3D visualization of mouse hearts by synchrotron radiation based μCT (SRμCT) and classical μCT. We demonstrate that SRμCT of PTA stained mouse hearts ex-vivo allows imaging of the cardiac atrium, ventricles, myocardium especially its fibre structure and vessel walls in great detail and furthermore enables the depiction of growth and anatomical changes during distinct developmental stages of hearts in mouse embryos. Our x-ray based virtual histology approach is not limited to SRμCT as it does not require monochromatic and/or coherent x-ray sources and even more importantly can be combined with conventional histological procedures. Furthermore, it permits volumetric measurements as we show for the assessment of the plaque volumes in the aortic valve region of mice from an ApoE-/- mouse model. Subsequent, Masson-Goldner trichrome staining of paraffin sections of PTA stained samples revealed intact collagen and muscle fibres and positive staining of CD31 on endothelial cells by immunohistochemistry illustrates that our approach does not prevent immunochemistry analysis. The feasibility to scan hearts already embedded in paraffin ensured a 100% correlation between virtual cut sections of the CT data sets and histological heart sections of the same sample and may allow in future guiding the cutting process to specific regions of interest. In summary, since our CT based virtual histology approach is a powerful tool for the 3D depiction of morphological alterations in hearts and embryos in high resolution and can be combined with classical histological analysis it may be used in preclinical research to unravel structural alterations of various heart diseases. PMID:28178293
Miksys, N; Xu, C; Beaulieu, L; Thomson, R M
2015-08-07
This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose calculation studies for various permanent implant brachytherapy treatments.
A virtual outpatient department provides a satisfactory patient experience following endoscopy.
Ryan, Elizabeth M; Rogers, Ailín C; Hanly, Ann M; McCawley, Niamh; Deasy, Joseph; McNamara, Deborah A
2014-03-01
The purpose of this study was to investigate telephone follow-up of post-endoscopy patients as an alternative to attendance at the outpatient department. Access to outpatient appointments is often a target for improvement in healthcare systems. Increased outpatient clinic capacity is not feasible without investment and extra manpower in an already constrained service. Outpatient attendance was audited at a busy colorectal surgical service. A subset of patients appropriate for follow-up in a "virtual outpatient department" (VOPD) were identified. A pilot study was designed and involved telephone follow-up of low-risk endoscopic procedures. Patient satisfaction was assessed using the Medical Interview Satisfaction Scale (MISS), which is a standardised survey of patient satisfaction with healthcare experiences. This was conducted via anonymous questionnaire at the end of the study. Of a total of 166 patients undergoing endoscopy in the time period, 79 were prospectively recruited to VOPD follow-up based on eligibility criteria. Overall, 67 (84.8 %) were successfully followed up by telephone consultation; nine patients (11.4 %) were contacted by mail. The remaining three patients (3.8 %) were brought back to the OPD. Patients recruited were more likely to be younger (55.82 ± 14.96 versus 60.78 ± 13.97 years, P = 0.029) and to have had normal examinations (49.4 versus 31.0 %, χ (2) = 5.070, P = 0.025). Nearly three quarters of patients responded to the questionnaire. The mean scores for all four aspects of the MISS were satisfactory, and overall patients were satisfied with the VOPD experience. VOPD is a target for improved healthcare provision, with improved efficiency and a high patient satisfaction rate.
Combined optical resolution photoacoustic and fluorescence micro-endoscopy
NASA Astrophysics Data System (ADS)
Shao, Peng; Shi, Wei; Hajireza, Parsin; Zemp, Roger J.
2012-02-01
We present a new micro-endoscopy system combining real-time C-scan optical-resolution photoacoustic micro-endoscopy (OR-PAME), and a high-resolution fluorescence micro-endoscopy system for visualizing fluorescently labeled cellular components and optically absorbing microvasculature simultaneously. With a diode-pumped 532-nm fiber laser, the OR-PAM sub-system is capable of imaging with a resolution of ~ 7μm. The fluorescence sub-system consists of a diode laser with 445 nm-centered emissions as the light source, an objective lens and a CCD camera. Proflavine, a FDA approved drug for human use, is used as the fluorescent contrast agent by topical application. The fluorescence system does not require any mechanical scanning. The scanning laser and the diode laser light source share the same light path within an optical fiber bundle containing 30,000 individual single mode fibers. The absorption of Proflavine at 532 nm is low, which mitigates absorption bleaching of the contrast agent by the photoacoustic excitation source. We demonstrate imaging in live murine models. The system is able to provide cellular morphology with cellular resolution co-registered with the structural and functional information given by OR-PAM. Therefore, the system has the potential to serve as a virtual biopsy technique, helping researchers and clinicians visualize angiogenesis, effects of anti-cancer drugs on both cells and the microcirculation, as well as aid in the study of other diseases.
Niu, Qiang; Chi, Xiaoyi; Leu, Ming C; Ochoa, Jorge
2008-01-01
This paper describes image processing, geometric modeling and data management techniques for the development of a virtual bone surgery system. Image segmentation is used to divide CT scan data into different segments representing various regions of the bone. A region-growing algorithm is used to extract cortical bone and trabecular bone structures systematically and efficiently. Volume modeling is then used to represent the bone geometry based on the CT scan data. Material removal simulation is achieved by continuously performing Boolean subtraction of the surgical tool model from the bone model. A quadtree-based adaptive subdivision technique is developed to handle the large set of data in order to achieve the real-time simulation and visualization required for virtual bone surgery. A Marching Cubes algorithm is used to generate polygonal faces from the volumetric data. Rendering of the generated polygons is performed with the publicly available VTK (Visualization Tool Kit) software. Implementation of the developed techniques consists of developing a virtual bone-drilling software program, which allows the user to manipulate a virtual drill to make holes with the use of a PHANToM device on a bone model derived from real CT scan data.
Infected Aneurysm after Endoscopic Submucosal Dissection.
Gen, Shiko; Usui, Ryuichi; Sasaki, Takaya; Nobe, Kanako; Takahashi, Aya; Okudaira, Keisuke; Ikeda, Naofumi
2016-01-01
A 79-year-old man on hemodialysis was hospitalized for further investigation. Early gastric cancer was diagnosed by gastrointestinal endoscopy and endoscopic submucosal dissection (ESD) was performed. Fever and abdominal pain thereafter developed, and a severe inflammatory response was observed on a blood test. Contrast computed tomography (CT) showed ulcer-like projections and soft tissue surrounding the aorta, from the celiac to left renal artery. An infected aneurysm was diagnosed. Although infected aneurysms developing after laparoscopic cholecystectomy or biopsy of contiguous esophageal duplication cyst have been reported, those developing after ESD have not. When fever and abdominal pain develop after ESD, an infected aneurysm should be considered and contrast CT performed.
Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz
2009-01-01
The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.
Fang, Yibin; Yu, Ying; Cheng, Jiyong; Wang, Shengzhang; Wang, Kuizhong; Liu, Jian-Min; Huang, Qinghai
2013-01-01
Adjusting hemodynamics via flow diverter (FD) implantation is emerging as a novel method of treating cerebral aneurysms. However, most previous FD-related hemodynamic studies were based on virtual FD deployment, which may produce different hemodynamic outcomes than realistic (in vivo) FD deployment. We compared hemodynamics between virtual FD and realistic FD deployments in rabbit aneurysm models using computational fluid dynamics (CFD) simulations. FDs were implanted for aneurysms in 14 rabbits. Vascular models based on rabbit-specific angiograms were reconstructed for CFD studies. Real FD configurations were reconstructed based on micro-CT scans after sacrifice, while virtual FD configurations were constructed with SolidWorks software. Hemodynamic parameters before and after FD deployment were analyzed. According to the metal coverage (MC) of implanted FDs calculated based on micro-CT reconstruction, 14 rabbits were divided into two groups (A, MC >35%; B, MC <35%). Normalized mean wall shear stress (WSS), relative residence time (RRT), inflow velocity, and inflow volume in Group A were significantly different (P<0.05) from virtual FD deployment, but pressure was not (P>0.05). The normalized mean WSS in Group A after realistic FD implantation was significantly lower than that of Group B. All parameters in Group B exhibited no significant difference between realistic and virtual FDs. This study confirmed MC-correlated differences in hemodynamic parameters between realistic and virtual FD deployment. PMID:23823503
Analysis of patient CT dose data using virtualdose
NASA Astrophysics Data System (ADS)
Bennett, Richard
X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT-Expo for organ dose difference versus age, male phantoms show percent difference of -19 % to 25 % for various organs minus bone surface and breast tissues results. Finally, for organ dose difference across all software for average adult phantom the results range from -45 % to 6 % in the comparison of ImPACT CT to VirtualDose and -27 % to 66 % for the comparison of CT-Expo to VirtualDose. In the comparison for increased BMI (done only in VirtualDose), results show that with all other parameters fixed, the organ dose goes down as BMI increases, which is due to the increase in adipose tissue and bulk of the patient model. The range of results when comparing all the three softwares have a wide range, in some cases greater than 150 %, it is evident that using a different anatomical basis for the human phantom and the theoretical basis for the dose estimation will cause fluctuation in the results. Therefore, choosing the software with the most accurate human phantom will provide a closer range to the true dose to the organ.
Prisman, Eitan; Daly, Michael J; Chan, Harley; Siewerdsen, Jeffrey H; Vescan, Allan; Irish, Jonathan C
2011-01-01
Custom software was developed to integrate intraoperative cone-beam computed tomography (CBCT) images with endoscopic video for surgical navigation and guidance. A cadaveric head was used to assess the accuracy and potential clinical utility of the following functionality: (1) real-time tracking of the endoscope in intraoperative 3-dimensional (3D) CBCT; (2) projecting an orthogonal reconstructed CBCT image, at or beyond the endoscope, which is parallel to the tip of the endoscope corresponding to the surgical plane; (3) virtual reality fusion of endoscopic video and 3D CBCT surface rendering; and (4) overlay of preoperatively defined contours of anatomical structures of interest. Anatomical landmarks were contoured in CBCT of a cadaveric head. An experienced endoscopic surgeon was oriented to the software and asked to rate the utility of the navigation software in carrying out predefined surgical tasks. Utility was evaluated using a rating scale for: (1) safely completing the task; and (2) potential for surgical training. Surgical tasks included: (1) uncinectomy; (2) ethmoidectomy; (3) sphenoidectomy/pituitary resection; and (4) clival resection. CBCT images were updated following each ablative task. As a teaching tool, the software was evaluated as "very useful" for all surgical tasks. Regarding safety and task completion, the software was evaluated as "no advantage" for task (1), "minimal" for task (2), and "very useful" for tasks (3) and (4). Landmark identification for structures behind bone was "very useful" for both categories. The software increased surgical confidence in safely completing challenging ablative tasks by presenting real-time image guidance for highly complex ablative procedures. In addition, such technology offers a valuable teaching aid to surgeons in training. Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC.
Wu, Rongli; Watanabe, Yoshiyuki; Satoh, Kazuhiko; Liao, Yen-Peng; Takahashi, Hiroto; Tanaka, Hisashi; Tomiyama, Noriyuki
2018-05-21
The aim of this study was to quantitatively compare the reduction in beam hardening artifact (BHA) and variance in computed tomography (CT) numbers of virtual monochromatic energy (VME) images obtained with 3 dual-energy computed tomography (DECT) systems at a given radiation dose. Five different iodine concentrations were scanned using dual-energy and single-energy (120 kVp) modes. The BHA and CT number variance were evaluated. For higher iodine concentrations, 40 and 80 mgI/mL, BHA on VME imaging was significantly decreased when the energy was higher than 50 keV (P = 0.003) and 60 keV (P < 0.001) for GE, higher than 80 keV (P < 0.001) and 70 keV (P = 0.002) for Siemens, and higher than 40 keV (P < 0.001) and 60 keV (P < 0.001) for Toshiba, compared with single-energy CT imaging. Virtual monochromatic energy imaging can decrease BHA and improve CT number accuracy in different dual-energy computed tomography systems, depending on energy levels and iodine concentrations.
Visuospatial skills and computer game experience influence the performance of virtual endoscopy.
Enochsson, Lars; Isaksson, Bengt; Tour, René; Kjellin, Ann; Hedman, Leif; Wredmark, Torsten; Tsai-Felländer, Li
2004-11-01
Advanced medical simulators have been introduced to facilitate surgical and endoscopic training and thereby improve patient safety. Residents trained in the Procedicus Minimally Invasive Surgical Trainer-Virtual Reality (MIST-VR) laparoscopic simulator perform laparoscopic cholecystectomy safer and faster than a control group. Little has been reported regarding whether factors like gender, computer experience, and visuospatial tests can predict the performance with a medical simulator. Our aim was to investigate whether such factors influence the performance of simulated gastroscopy. Seventeen medical students were asked about computer gaming experiences. Before virtual endoscopy, they performed the visuospatial test PicCOr, which discriminates the ability of the tested person to create a three-dimensional image from a two-dimensional presentation. Each student performed one gastroscopy (level 1, case 1) in the GI Mentor II, Simbionix, and several variables related to performance were registered. Percentage of time spent with a clear view in the endoscope correlated well with the performance on the PicSOr test (r = 0.56, P < 0.001). Efficiency of screening also correlated with PicSOr (r = 0.23, P < 0.05). In students with computer gaming experience, the efficiency of screening increased (33.6% +/- 3.1% versus 22.6% +/- 2.8%, P < 0.05) and the duration of the examination decreased by 1.5 minutes (P < 0.05). A similar trend was seen in men compared with women. The visuospatial test PicSOr predicts the results with the endoscopic simulator GI Mentor II. Two-dimensional image experience, as in computer games, also seems to affect the outcome.
Virtual airway simulation to improve dexterity among novices performing fibreoptic intubation.
De Oliveira, G S; Glassenberg, R; Chang, R; Fitzgerald, P; McCarthy, R J
2013-10-01
We developed a virtual reality software application (iLarynx) using built-in accelerometer properties of the iPhone(®) or iPad(®) (Apple Inc., Cupertino, CA, USA) that mimics hand movements for the performance of fibreoptic skills. Twenty novice medical students were randomly assigned to virtual airway training with the iLarynx software or no additional training. Eight out of the 10 subjects in the standard training group had at least one failed (> 120 s) attempt compared with two out of the 10 participants in the iLarynx group (p = 0.01). There were a total of 24 failed attempts in the standard training group and four in the iLarynx group (p < 0.005). Cusum analysis demonstrated continued group improvement in the iLarynx, but not in the standard training group. Virtual airway simulation using freely available software on a smartphone/tablet device improves dexterity among novices performing upper airway endoscopy. © 2013 The Association of Anaesthetists of Great Britain and Ireland.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michalak, Gregory; Grimes, Joshua; Fletcher, Joel
2016-01-15
Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kVmore » beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.« less
Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Halaweish, Ahmed; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia
2016-01-01
The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. The authors' report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.
Uchida, Masafumi
2014-04-01
A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Brown, Tamara; Beaufrère, Hugues; Brisson, Brigitte; Laniesse, Delphine; zur Linden, Alex
2016-01-01
A rabbit was presented for severe dyspnea and was diagnosed with an odontogenic abscess obstructing the rostral nasopharynx using CT scan and oral endoscopy. The offending tooth was extracted intraorally, but due to persistent dyspnea, an endoscopic-guided ventral rhinotomy was performed. The dyspnea subsequently resolved, but the rabbit died 5 weeks later from a seemingly unrelated cause. PMID:27493289
[Virtual colonoscopy is now reality].
Pedersen, Bodil Ginnerup; Achiam, Michael P; Arnesen, Regnar Bøge
2005-10-31
Virtual colonoscopy involves a helical CT or MR scan of the abdomen and pelvis to detect colorectal polyps and cancer. Both modalities have shown promising sensitivity in revealing larger polyps, in comparison with colonoscopy. Caution should be exercised in its clinical implementation due to significant interobserver variation and individual learning curves. A Danish study indicates that CT colonography (CTC) can be performed cost-effectively compared to colonoscopy. CTC is recommended in preference to double-contrast barium enema after incomplete colonoscopy.
Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D
2017-09-01
Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.
Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis
Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh
2017-01-01
Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis. PMID:29317945
Primary Jejunal Adenocarcinoma Presenting as Bilateral Ovarian Metastasis.
Ofori, Emmanuel; Ramai, Daryl; Papafragkakis, Charilaos; Changela, Kinesh; Krishnaiah, Mahesh
2017-12-01
Small intestinal tumors are rare with adenocarcinoma of the small intestine accounting for less than 2% of all gastrointestinal cancers. Primary jejunal adenocarcinoma constitutes a minute portion of small intestine adenocarcinomas. Clinically, this cancer presents at latter stages of its progression, mainly due to vague and non-specific symptoms, and the difficulty encountered in accessing the jejunum on upper endoscopy. Diagnosis of jejunal adenocarcinoma is usually inconclusive with the use of computed tomography (CT) scan, small bowel series, or upper endoscopy. Laparoscopy followed by frozen section biopsy provides a definitive diagnosis. In the past decade, balloon-assisted enteroscopy (BAE) and capsule endoscopy have become popular as useful modalities for diagnosing small bowel diseases. Wide excisional jejunectomy is the only treatment option with an estimated 5-year survival of 40-65%. Physicians are advised to suspect jejunal adenocarcinoma as a differential diagnosis in patients who present with non-specific symptoms of abdominal pain, nausea, vomiting, weight loss, anemia, gastrointestinal bleeding or signs of small bowel obstruction. We present a rare case of a 37-year-old woman with suspected bilateral ovarian masses, which was immunohistochemically confirmed as primary jejunal adenocarcinoma with bilateral ovarian metastasis.
Kong, Seong-Ho; Haouchine, Nazim; Soares, Renato; Klymchenko, Andrey; Andreiuk, Bohdan; Marques, Bruno; Shabat, Galyna; Piechaud, Thierry; Diana, Michele; Cotin, Stéphane; Marescaux, Jacques
2017-07-01
Augmented reality (AR) is the fusion of computer-generated and real-time images. AR can be used in surgery as a navigation tool, by creating a patient-specific virtual model through 3D software manipulation of DICOM imaging (e.g., CT scan). The virtual model can be superimposed to real-time images enabling transparency visualization of internal anatomy and accurate localization of tumors. However, the 3D model is rigid and does not take into account inner structures' deformations. We present a concept of automated AR registration, while the organs undergo deformation during surgical manipulation, based on finite element modeling (FEM) coupled with optical imaging of fluorescent surface fiducials. Two 10 × 1 mm wires (pseudo-tumors) and six 10 × 0.9 mm fluorescent fiducials were placed in ex vivo porcine kidneys (n = 10). Biomechanical FEM-based models were generated from CT scan. Kidneys were deformed and the shape changes were identified by tracking the fiducials, using a near-infrared optical system. The changes were registered automatically with the virtual model, which was deformed accordingly. Accuracy of prediction of pseudo-tumors' location was evaluated with a CT scan in the deformed status (ground truth). In vivo: fluorescent fiducials were inserted under ultrasound guidance in the kidney of one pig, followed by a CT scan. The FEM-based virtual model was superimposed on laparoscopic images by automatic registration of the fiducials. Biomechanical models were successfully generated and accurately superimposed on optical images. The mean measured distance between the estimated tumor by biomechanical propagation and the scanned tumor (ground truth) was 0.84 ± 0.42 mm. All fiducials were successfully placed in in vivo kidney and well visualized in near-infrared mode enabling accurate automatic registration of the virtual model on the laparoscopic images. Our preliminary experiments showed the potential of a biomechanical model with fluorescent fiducials to propagate the deformation of solid organs' surface to their inner structures including tumors with good accuracy and automatized robust tracking.
[Development of a software for 3D virtual phantom design].
Zou, Lian; Xie, Zhao; Wu, Qi
2014-02-01
In this paper, we present a 3D virtual phantom design software, which was developed based on object-oriented programming methodology and dedicated to medical physics research. This software was named Magical Phan tom (MPhantom), which is composed of 3D visual builder module and virtual CT scanner. The users can conveniently construct any complex 3D phantom, and then export the phantom as DICOM 3.0 CT images. MPhantom is a user-friendly and powerful software for 3D phantom configuration, and has passed the real scene's application test. MPhantom will accelerate the Monte Carlo simulation for dose calculation in radiation therapy and X ray imaging reconstruction algorithm research.
Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M
2017-03-01
To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Diagnosis and evaluation of gastric cancer by positron emission tomography
Wu, Chen-Xi; Zhu, Zhao-Hui
2014-01-01
Gastric cancer is the second leading cause of cancer mortality worldwide. The diagnosis of gastric cancer has been significantly improved with the broad availability of gastrointestinal endoscopy. Effective technologies for accurate staging and quantitative evaluation are still in demand to merit reasonable treatment and better prognosis for the patients presented with advanced disease. Preoperative staging using conventional imaging tools, such as computed tomography (CT) and endoscopic ultrasonography, is inadequate. Positron emission tomography (PET), using 18F-fluorodeoxyglucose (FDG) as a tracer and integrating CT for anatomic localization, holds a promise to detect unsuspected metastasis and has been extensively used in a variety of malignancies. However, the value of FDG PET/CT in diagnosis and evaluation of gastric cancer is still controversial. This article reviews the current literature in diagnosis, staging, response evaluation, and relapse monitoring of gastric cancer, and discusses the current understanding, improvement, and future prospects in this area. PMID:24782610
Ferraz, Eduardo Gomes; Andrade, Lucio Costa Safira; dos Santos, Aline Rode; Torregrossa, Vinicius Rabelo; Rubira-Bullen, Izabel Regina Fischer; Sarmento, Viviane Almeida
2013-12-01
The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols ("outline only" and "all-boundary lines"). Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %. The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24). During the designing of a virtual 3D reconstruction, both "outline only" and "all-boundary lines" segmentation protocols can be used. Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.
Inter-algorithm lesion volumetry comparison of real and 3D simulated lung lesions in CT
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Hoye, Jocelyn; Smith, Taylor; Ebner, Lukas; Samei, Ehsan
2017-03-01
The purpose of this study was to establish volumetric exchangeability between real and computational lung lesions in CT. We compared the overall relative volume estimation performance of segmentation tools when used to measure real lesions in actual patient CT images and computational lesions virtually inserted into the same patient images (i.e., hybrid datasets). Pathologically confirmed malignancies from 30 thoracic patient cases from Reference Image Database to Evaluate Therapy Response (RIDER) were modeled and used as the basis for the comparison. Lesions included isolated nodules as well as those attached to the pleura or other lung structures. Patient images were acquired using a 16 detector row or 64 detector row CT scanner (Lightspeed 16 or VCT; GE Healthcare). Scans were acquired using standard chest protocols during a single breath-hold. Virtual 3D lesion models based on real lesions were developed in Duke Lesion Tool (Duke University), and inserted using a validated image-domain insertion program. Nodule volumes were estimated using multiple commercial segmentation tools (iNtuition, TeraRecon, Inc., Syngo.via, Siemens Healthcare, and IntelliSpace, Philips Healthcare). Consensus based volume comparison showed consistent trends in volume measurement between real and virtual lesions across all software. The average percent bias (+/- standard error) shows -9.2+/-3.2% for real lesions versus -6.7+/-1.2% for virtual lesions with tool A, 3.9+/-2.5% and 5.0+/-0.9% for tool B, and 5.3+/-2.3% and 1.8+/-0.8% for tool C, respectively. Virtual lesion volumes were statistically similar to those of real lesions (< 4% difference) with p >.05 in most cases. Results suggest that hybrid datasets had similar inter-algorithm variability compared to real datasets.
Wallach, Helene S; Safir, Marilyn P; Bar-Zvi, Margalit
2011-01-01
To determine the utility of Virtual Reality Exposure Therapy (VRE) in comparison with Cognitive Therapy (CT ) and with Cognitive-Behavior Therapy (CBT). Subjects suffering from public speaking anxiety (PSA) were randomly allocated to VRE and CT , and received 12 therapy sessions, employing standardized treatment manuals. Outcome (questionnaires, observer and self ratings of a behavioral task) was compared to results of subjects in a previous study CBT and Wait List Controls who were not significantly different on demographic data. CT was not superior to VRE on cognitive measures, but was superior to VRE on one behavioral measure (LSAS fear). VRE was superior to CT on one behavioral measure (fear reduction on a behavioral task). No differences were found between either CT , or VRE, and CBT and all were superior to WL. Subject group was small and homogeneous. It appeared advisable to increase number of therapy sessions. VRE and CT proved to be equally effective to CBT in reducing PSA relative to a control group, with minimal differential effects between them. Therefore, employing either one may be satisfactory and sufficient.
Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.
Hoffman, Heidi; Torres, William E; Ernst, Randy D
2002-01-01
Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002
DIBRA, A.; KËLLIÇI, S.; ÇELIKU, E.; DRAÇINI, Xh.; MATURO, A.; ÇELIKU, E.
2015-01-01
We present a case of intramural duodenal hematoma as a complication of endoscopic therapy for a bleeding duodenal ulcer in an adult patient with no evidence of other pathologies. A 18-year-old man was admitted in emergency room with gastrointestinal bleeding manifested by melena. Previous medical history revealed that he had endoscopic sclerotherapy for bleeding duodenal ulcer 5 months before. Endoscopy revealed a Forrest 2a ulcer in the duodenal bulb and sclerotherapy was performed by injecting 10 ml of 0.2% epinephrine and 20 ml of NaCl 0.9% solution. Upper occlusion’s signs appeared 36 hours after the procedure. The hematoma, that was identified by endoscopy and confirmed by MRI and CT scan of the abdomen, caused transient duodenal obstruction. Combined conservative management with nasogastric tube and total parenteral nutrition resulted in reduction of obstructive symptoms within 4 weeks. PMID:25827667
Dibra, A; Këlliçi, S; Çeliku, E; Draçini, Xh; Maturo, A; Çeliku, E
2015-01-01
We present a case of intramural duodenal hematoma as a complication of endoscopic therapy for a bleeding duodenal ulcer in an adult patient with no evidence of other pathologies. A 18-year-old man was admitted in emergency room with gastrointestinal bleeding manifested by melena. Previous medical history revealed that he had endoscopic sclerotherapy for bleeding duodenal ulcer 5 months before. Endoscopy revealed a Forrest 2a ulcer in the duodenal bulb and sclerotherapy was performed by injecting 10 ml of 0.2% epinephrine and 20 ml of Na- Cl 0.9% solution. Upper occlusion's signs appeared 36 hours after the procedure. The hematoma, that was identified by endoscopy and confirmed by MRI and CT scan of the abdomen, caused transient duodenal obstruction. Combined conservative management with nasogastric tube and total parenteral nutrition resulted in reduction of obstructive symptoms within 4 weeks.
Virtual chromoendoscopy can be a useful software tool in capsule endoscopy.
Duque, Gabriela; Almeida, Nuno; Figueiredo, Pedro; Monsanto, Pedro; Lopes, Sandra; Freire, Paulo; Ferreira, Manuela; Carvalho, Rita; Gouveia, Hermano; Sofia, Carlos
2012-05-01
capsule endoscopy (CE) has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE) that allows for virtual chromoendoscopy is one of these software tools. to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agreement between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding). in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650). In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32), and erosions (41 vs. 24). there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren´t identified by the conventional mode.
Saito, Masatoshi
2015-07-01
For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose of the present study was to reveal the relation between the ΔHU image for ρe calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. The author determined the weighting factor, α0, of the ΔHU-ρe conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρe values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the xcom photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80-140 and 100-140 kV/Sn. The determined α0 values were 0.455 for 80-140 kV/Sn and 0.743 for 100-140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.
An augmented reality tool for learning spatial anatomy on mobile devices.
Jain, Nishant; Youngblood, Patricia; Hasel, Matthew; Srivastava, Sakti
2017-09-01
Augmented Realty (AR) offers a novel method of blending virtual and real anatomy for intuitive spatial learning. Our first aim in the study was to create a prototype AR tool for mobile devices. Our second aim was to complete a technical evaluation of our prototype AR tool focused on measuring the system's ability to accurately render digital content in the real world. We imported Computed Tomography (CT) data derived virtual surface models into a 3D Unity engine environment and implemented an AR algorithm to display these on mobile devices. We investigated the accuracy of the virtual renderings by comparing a physical cube with an identical virtual cube for dimensional accuracy. Our comparative study confirms that our AR tool renders 3D virtual objects with a high level of accuracy as evidenced by the degree of similarity between measurements of the dimensions of a virtual object (a cube) and the corresponding physical object. We developed an inexpensive and user-friendly prototype AR tool for mobile devices that creates highly accurate renderings. This prototype demonstrates an intuitive, portable, and integrated interface for spatial interaction with virtual anatomical specimens. Integrating this AR tool with a library of CT derived surface models provides a platform for spatial learning in the anatomy curriculum. The segmentation methodology implemented to optimize human CT data for mobile viewing can be extended to include anatomical variations and pathologies. The ability of this inexpensive educational platform to deliver a library of interactive, 3D models to students worldwide demonstrates its utility as a supplemental teaching tool that could greatly benefit anatomical instruction. Clin. Anat. 30:736-741, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
An Indirect Method to Measure Abutment Screw Preload: A Pilot Study Based on Micro-CT Scanning.
Rezende, Carlos Eduardo E; Griggs, Jason Alan; Duan, Yuanyuan; Mushashe, Amanda M; Nolasco, Gisele Maria Correr; Borges, Ana Flávia Sanches; Rubo, José Henrique
2015-01-01
This study aimed to measure the preload in different implant platform geometries based on micro-CT images. External hexagon (EH) implants and Morse Tapered (MT) implants (n=5) were used for the preload measurement. The abutment screws were scanned in micro-CT to obtain their virtual models, which were used to record their initial length. The abutments were screwed on the implant with a 20 Ncm torque and the set composed by implant, abutment screw and abutment were taken to the micro-CT scanner to obtain virtual slices of the specimens. These slices allowed the measurement of screw lengths after torque application and based on the screw elongation. Preload values were calculated using the Hooke's Law. The preloads of both groups were compared by independent t-test. Removal torque of each specimen was recorded. To evaluate the accuracy of the micro-CT technique, three rods with known lengths were scanned and the length of their virtual model was measured and compared with the original length. One rod was scanned four times to evaluate the measuring method variation. There was no difference between groups for preload (EH = 461.6 N and MT = 477.4 N), but the EH group showed higher removal torque values (13.8 ± 4.7 against 8.2 ± 3.6 N cm for MT group). The micro-CT technique showed a variability of 0.053% and repeatability showed an error of 0.23 to 0.28%. Within the limitations of this study, there was no difference between external hexagon and Morse taper for preload. The method using micro-CT may be considered for preload calculation.
Bodanapally, U K; Dreizin, D; Issa, G; Archer-Arroyo, K L; Sudini, K; Fleiter, T R
2017-10-01
Extravasation of iodinated contrast into subdural space following contrast-enhanced radiographic studies results in hyperdense subdural effusions, which can be mistaken as acute subdural hematomas on follow-up noncontrast head CTs. Our aim was to identify the factors associated with contrast-enhancing subdural effusion, characterize diffusion and washout kinetics of iodine in enhancing subdural effusion, and assess the utility of dual-energy CT in differentiating enhancing subdural effusion from subdural hematoma. We retrospectively analyzed follow-up head dual-energy CT studies in 423 patients with polytrauma who had undergone contrast-enhanced whole-body CT. Twenty-four patients with enhancing subdural effusion composed the study group, and 24 randomly selected patients with subdural hematoma were enrolled in the comparison group. Postprocessing with syngo.via was performed to determine the diffusion and washout kinetics of iodine. The sensitivity and specificity of dual-energy CT for the diagnosis of enhancing subdural effusion were determined with 120-kV, virtual monochromatic energy (190-keV) and virtual noncontrast images. Patients with enhancing subdural effusion were significantly older (mean, 69 years; 95% CI, 60-78 years; P < .001) and had a higher incidence of intracranial hemorrhage ( P = .001). Peak iodine concentration in enhancing subdural effusions was reached within the first 8 hours of contrast administration with a mean of 0.98 mg/mL (95% CI, 0.81-1.13 mg/mL), and complete washout was achieved at 38 hours. For the presence of a hyperdense subdural collection on 120-kV images with a loss of hyperattenuation on 190-keV and virtual noncontrast images, when considered as a true-positive for enhancing subdural effusion, the sensitivity was 100% (95% CI, 85.75%-100%) and the specificity was 91.67% (95% CI, 73%-99%). Dual-energy CT has a high sensitivity and specificity in differentiating enhancing subdural effusion from subdural hematoma. Hence, dual-energy CT has a potential to obviate follow-up studies. © 2017 by American Journal of Neuroradiology.
Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo
2017-10-01
Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.
Liu, Jin-Ya; Chen, Li-Da; Cai, Hua-Song; Liang, Jin-Yu; Xu, Ming; Huang, Yang; Li, Wei; Feng, Shi-Ting; Xie, Xiao-Yan; Lu, Ming-De; Wang, Wei
2016-01-01
AIM: To present our initial experience regarding the feasibility of ultrasound virtual endoscopy (USVE) and its measurement reliability for polyp detection in an in vitro study using pig intestine specimens. METHODS: Six porcine intestine specimens containing 30 synthetic polyps underwent USVE, computed tomography colonography (CTC) and optical colonoscopy (OC) for polyp detection. The polyp measurement defined as the maximum polyp diameter on two-dimensional (2D) multiplanar reformatted (MPR) planes was obtained by USVE, and the absolute measurement error was analyzed using the direct measurement as the reference standard. RESULTS: USVE detected 29 (96.7%) of 30 polyps, remaining a 7-mm one missed. There was one false-positive finding. Twenty-six (89.7%) of 29 reconstructed images were clearly depicted, while 29 (96.7%) of 30 polyps were displayed on CTC with one false-negative finding. In OC, all the polyps were detected. The intraclass correlation coefficient was 0.876 (95%CI: 0.745-0.940) for measurements obtained with USVE. The pooled absolute measurement errors ± the standard deviations of the depicted polyps with actual sizes ≤ 5 mm, 6-9 mm, and ≥ 10 mm were 1.9 ± 0.8 mm, 0.9 ± 1.2 mm, and 1.0 ± 1.4 mm, respectively. CONCLUSION: USVE is reliable for polyp detection and measurement in in vitro study. PMID:27022217
Grover, Samir C; Garg, Ankit; Scaffidi, Michael A; Yu, Jeffrey J; Plener, Ian S; Yong, Elaine; Cino, Maria; Grantcharov, Teodor P; Walsh, Catharine M
2015-12-01
GI endoscopy simulation-based training augments early clinical performance; however, the optimal manner by which to deliver training is unknown. We aimed to validate a simulation-based structured comprehensive curriculum (SCC) designed to teach technical, cognitive, and integrative competencies in colonoscopy. Single-blinded, randomized, controlled trial. Endoscopic simulation course at an academic hospital. Thirty-three novice endoscopists were allocated to an SCC group or self-regulated learning (SRL) group. The SCC group received a curriculum consisting of 6 hours of didactic lectures and 8 hours of virtual reality simulation-based training with expert feedback. The SRL group was provided a list of desired objectives and was instructed to practice on the simulator for an equivalent time (8 hours). Clinical transfer was assessed during 2 patient colonoscopies using the Joint Advisory Group Direct Observation of Procedural Skills (JAG DOPS) scale. Secondary outcome measures included differences in procedural knowledge, immediate post-training simulation performance, and delayed post-training (4-6 weeks) performance during an integrated scenario test on the JAG DOPS communication and integrated scenario global rating scales. There was no significant difference in baseline or post-training performance on the simulator task. The SCC group performed superiorly during their first and second clinical colonoscopies. Additionally, the SCC group demonstrated significantly better knowledge and colonoscopy-specific performance, communication, and global performance during the integrated scenario. We were unable to measure SRL participants' effort outside of mandatory training. In addition, feedback metrics and number of available simulation cases are limited. These results support integration of endoscopy simulation into a structured curriculum incorporating instructional feedback and complementary didactic knowledge as a means to augment technical, cognitive, and integrative skills acquisition, as compared with SRL on virtual reality simulators. ( NCT01991522.) Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Wang, Y Y; Zhang, H Q; Fan, S; Zhang, D M; Huang, Z Q; Chen, W L; Ye, J T; Li, J S
2016-11-01
This study evaluated the accuracy of mandibular reconstruction and assessed clinical outcomes in both virtual planning and conventional surgery patients. ProPlan CMF surgical planning software was used preoperatively in the virtual planning group. In the virtual planning group, fibula flaps were harvested and osteotomized, and the mandibles were resected and reconstructed assisted by the prefabricated cutting guides and templates. The main outcome measures included the operative time, postoperative computed tomography (CT) scans, facial appearance, and occlusal function. The ischemia time and total operation time were shorter in the virtual planning group than in the conventional surgery group. High precision with the use of the cutting guides and templates was found for both the fibula and mandible, and a good fit was noted among the pre-bent plate, mandible, and fibula segments in the virtual planning group. Postoperative CT scans also showed excellent mandibular contours of the fibula flaps in accordance with virtual plans in the virtual planning group. This study demonstrated that virtual surgical planning was able to achieve more accurate mandibular reconstruction than conventional surgery. The use of prefabricated cutting guides and plates makes fibula flap moulding and placement easier, minimizes the operating time, and improves clinical outcomes. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Plot of virtual surgery based on CT medical images
NASA Astrophysics Data System (ADS)
Song, Limei; Zhang, Chunbo
2009-10-01
Although the CT device can give the doctors a series of 2D medical images, it is difficult to give vivid view for the doctors to acknowledge the decrease part. In order to help the doctors to plot the surgery, the virtual surgery system is researched based on the three-dimensional visualization technique. After the disease part of the patient is scanned by the CT device, the 3D whole view will be set up based on the 3D reconstruction module of the system. TCut a part is the usually used function for doctors in the real surgery. A curve will be created on the 3D space; and some points can be added on the curve automatically or manually. The position of the point can change the shape of the cut curves. The curve can be adjusted by controlling the points. If the result of the cut function is not satisfied, all the operation can be cancelled to restart. The flexible virtual surgery gives more convenience to the real surgery. Contrast to the existing medical image process system, the virtual surgery system is added to the system, and the virtual surgery can be plotted for a lot of times, till the doctors have enough confidence to start the real surgery. Because the virtual surgery system can give more 3D information of the disease part, some difficult surgery can be discussed by the expert doctors in different city via internet. It is a useful function to understand the character of the disease part, thus to decrease the surgery risk.
de Kleijn, Bertram J; Kraeima, Joep; Wachters, Jasper E; van der Laan, Bernard F A M; Wedman, Jan; Witjes, M J H; Halmos, Gyorgy B
2018-02-01
We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. 3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed. (1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed. Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy.
Poorey, V K; Gupta, Neha
2014-09-01
To correlate symptoms of deviated nasal septum (DNS) and chronic rhinosinusitis with the findings of nasal endoscopy and computed tomographic (CT) imaging. To evaluate the influence of degree of septal angle deviation on the severity of lateral nasal wall abnormalities. A prospective study was conducted on 67 patients with clinical evidence of DNS and chronic sinusitis attending ENT OPD between January 2012 and September 2013. All these patients underwent nasal endoscopy and CT scan PNS coronal sections. Direction and degree of DNS was recorded. Range of sinus mucosal thickening on CT scan films was also recorded. Chronic sinusitis is common in the age group between 21 and 40 years (50.74 %) with male preponderance (55.22 %), chief symptoms being nasal obstruction (86.56 %), headache (73.13 %) and nasal discharge (52.23 %). Left sided DNS is more common (64.17 %). Most of the patients have moderate DNS, i.e. 6°-10° (56.7 %), followed by severe (22.4 %) and then mild (20.9 %). DNS results in compensatory structural changes in the turbinates and/or lateral nasal wall which causes ostiomeatal complex (OMC) obstruction resulting in sinusitis. Contralateral concha bullosa and ethmoid bulla prominence was noted. Maxillary sinus is most commonly affected sinus (73.13 %). Patients with increasing septal angles were associated with a higher incidence of maxillary sinus mucosal changes (p < 0.05). Present study reemphasized the concept that septal deviation causes obstruction at OMC which results in an increased incidence and severity of bilateral chronic sinus disease.
Meisner, Eric M; Hager, Gregory D; Ishman, Stacey L; Brown, David; Tunkel, David E; Ishii, Masaru
2013-11-01
To evaluate the accuracy of three-dimensional (3D) airway reconstructions obtained using quantitative endoscopy (QE). We developed this novel technique to reconstruct precise 3D representations of airway geometries from endoscopic video streams. This method, based on machine vision methodologies, uses a post-processing step of the standard videos obtained during routine laryngoscopy and bronchoscopy. We hypothesize that this method is precise and will generate assessment of airway size and shape similar to those obtained using computed tomography (CT). This study was approved by the institutional review board (IRB). We analyzed video sequences from pediatric patients receiving rigid bronchoscopy. We generated 3D scaled airway models of the subglottis, trachea, and carina using QE. These models were compared to 3D airway models generated from CT. We used the CT data as the gold standard measure of airway size, and used a mixed linear model to estimate the average error in cross-sectional area and effective diameter for QE. The average error in cross sectional area (area sliced perpendicular to the long axis of the airway) was 7.7 mm(2) (variance 33.447 mm(4)). The average error in effective diameter was 0.38775 mm (variance 2.45 mm(2)), approximately 9% error. Our pilot study suggests that QE can be used to generate precise 3D reconstructions of airways. This technique is atraumatic, does not require ionizing radiation, and integrates easily into standard airway assessment protocols. We conjecture that this technology will be useful for staging airway disease and assessing surgical outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Whole-Body CT Screening--Should I or Shouldn't I Get One?
... lung cancer in smokers of particular ages, CT virtual colonoscopy is as good as colonoscopy in men ... that resemble the disease or condition which in reality would not hurt you, when the test doesn' ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, W; Yang, J; Beadle, B
Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through themore » volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.« less
Limited utility of MRA for acute bowel ischemia after portal venous phase CT.
Shetty, Anup S; Mellnick, Vincent M; Raptis, Constantine; Loch, Ronald; Owen, Joseph; Bhalla, Sanjeev
2015-10-01
Mesenteric ischemia and ischemic colitis are uncommon but potentially life-threatening causes of acute abdominal pain. Portal venous phase computed tomography (CT) is routinely ordered in the emergency room setting for abdominal pain, but subsequent MR angiography may be requested for additional evaluation of the mesenteric vasculature. We compare the concordance of CT and magnetic resonance angiography (MRA) for acute bowel ischemia. Thirty-two patients who underwent contrast-enhanced MRA for bowel ischemia after having undergone CT evaluation within the preceding 2 weeks were identified. A retrospective review of imaging, treatment history, surgical, and pathology reports was conducted. Two radiologists each reviewed the imaging studies in a blinded fashion. Ten cases of bowel ischemia were confirmed by endoscopy and/or surgical pathology. CT correctly identified bowel findings in all cases. Intraobserver agreement between CT and MRA for all vessels was 0.68 and 0.63, highest for the superior mesenteric artery. Interobserver agreement was 0.74 for MRA and 0.78 for CT. Vascular findings were only directly mentioned in 10 of 32 CT reports (and 7 of 10 cases with confirmed bowel ischemia). MRA only detected two additional or alternative diagnoses. Portal venous phase CT and MRA demonstrate a high degree of concordance for vascular evaluation. Reviewed CT examinations were sufficient to assess the patency of the mesenteric vasculature, but vascular findings were not reported in most cases. A direct description within the report may have obviated the request for further MR imaging. MRA adds little value after portal venous CT in assessing bowel ischemia.
Nickenig, Hans-Joachim; Eitner, Stephan
2007-01-01
We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.
Visuomotor adaptation in head-mounted virtual reality versus conventional training
Anglin, J. M.; Sugiyama, T.; Liew, S.-L.
2017-01-01
Immersive, head-mounted virtual reality (HMD-VR) provides a unique opportunity to understand how changes in sensory environments affect motor learning. However, potential differences in mechanisms of motor learning and adaptation in HMD-VR versus a conventional training (CT) environment have not been extensively explored. Here, we investigated whether adaptation on a visuomotor rotation task in HMD-VR yields similar adaptation effects in CT and whether these effects are achieved through similar mechanisms. Specifically, recent work has shown that visuomotor adaptation may occur via both an implicit, error-based internal model and a more cognitive, explicit strategic component. We sought to measure both overall adaptation and balance between implicit and explicit mechanisms in HMD-VR versus CT. Twenty-four healthy individuals were placed in either HMD-VR or CT and trained on an identical visuomotor adaptation task that measured both implicit and explicit components. Our results showed that the overall timecourse of adaption was similar in both HMD-VR and CT. However, HMD-VR participants utilized a greater cognitive strategy than CT, while CT participants engaged in greater implicit learning. These results suggest that while both conditions produce similar results in overall adaptation, the mechanisms by which visuomotor adaption occurs in HMD-VR appear to be more reliant on cognitive strategies. PMID:28374808
Novel application of three-dimensional technologies in a case of dismemberment.
Baier, Waltraud; Norman, Danielle G; Warnett, Jason M; Payne, Mark; Harrison, Nigel P; Hunt, Nicholas C A; Burnett, Brian A; Williams, Mark A
2017-01-01
This case study reports the novel application of three-dimensional technologies such as micro-CT and 3D printing to the forensic investigation of a complex case of dismemberment. Micro-CT was successfully employed to virtually align severed skeletal elements found in different locations, analyse tool marks created during the dismemberment process, and virtually dissect a charred piece of evidence. High resolution 3D prints of the burnt human bone contained within were created for physical visualisation to assist the investigation team. Micro-CT as a forensic radiological method provided vital information and the basis for visualisation both during the investigation and in the subsequent trial making it one of the first examples of such technology in a UK court. Copyright © 2016. Published by Elsevier B.V.
Dreizin, David; Nam, Arthur J; Hirsch, Jeffrey; Bernstein, Mark P
2018-06-20
This article reviews the conceptual framework, available evidence, and practical considerations pertaining to nascent and emerging advances in patient-centered CT-imaging and CT-guided surgery for maxillofacial trauma. These include cinematic rendering-a novel method for advanced 3D visualization, incorporation of quantitative CT imaging into the assessment of orbital fractures, low-dose CT imaging protocols made possible with contemporary scanners and reconstruction techniques, the rapidly growing use of cone-beam CT, virtual fracture reduction with design software for surgical pre-planning, the use of 3D printing for fabricating models and implants, and new avenues in CT-guided computer-aided surgery.
Virtual Reality Exploration and Planning for Precision Colorectal Surgery.
Guerriero, Ludovica; Quero, Giuseppe; Diana, Michele; Soler, Luc; Agnus, Vincent; Marescaux, Jacques; Corcione, Francesco
2018-06-01
Medical software can build a digital clone of the patient with 3-dimensional reconstruction of Digital Imaging and Communication in Medicine images. The virtual clone can be manipulated (rotations, zooms, etc), and the various organs can be selectively displayed or hidden to facilitate a virtual reality preoperative surgical exploration and planning. We present preliminary cases showing the potential interest of virtual reality in colorectal surgery for both cases of diverticular disease and colonic neoplasms. This was a single-center feasibility study. The study was conducted at a tertiary care institution. Two patients underwent a laparoscopic left hemicolectomy for diverticular disease, and 1 patient underwent a laparoscopic right hemicolectomy for cancer. The 3-dimensional virtual models were obtained from preoperative CT scans. The virtual model was used to perform preoperative exploration and planning. Intraoperatively, one of the surgeons was manipulating the virtual reality model, using the touch screen of a tablet, which was interactively displayed to the surgical team. The main outcome was evaluation of the precision of virtual reality in colorectal surgery planning and exploration. In 1 patient undergoing laparoscopic left hemicolectomy, an abnormal origin of the left colic artery beginning as an extremely short common trunk from the inferior mesenteric artery was clearly seen in the virtual reality model. This finding was missed by the radiologist on CT scan. The precise identification of this vascular variant granted a safe and adequate surgery. In the remaining cases, the virtual reality model helped to precisely estimate the vascular anatomy, providing key landmarks for a safer dissection. A larger sample size would be necessary to definitively assess the efficacy of virtual reality in colorectal surgery. Virtual reality can provide an enhanced understanding of crucial anatomical details, both preoperatively and intraoperatively, which could contribute to improve safety in colorectal surgery.
Dale, Einar; Moan, Jon M; Osnes, Terje A; Bogsrud, Trond V
2017-02-01
FDG PET/CT is perceived as a valuable diagnostic tool in addition to the standard diagnostic workup for patients with isolated neck lymph nodes of squamous cell carcinoma of unknown primary (SCCUP). For patients with SCCUP intended for primary radiotherapy, we hypothesize that the previously reported FDG PET/CT detection rates are too high. From 2008 to 2015, 30 SCCUP patients were examined with FDG PET/CT. The objective of the FDG PET/CT examination was twofold: (1) improve the radiotherapy target definition, and (2) identify the primary cancer. Before the FDG PET/CT, the patients had been through a standard workup consisting of CT of the neck and chest, examination with flexible endoscopy with patient awake, panendoscopy and examination under general anesthesia, tonsillectomy and sometimes blind sampling biopsies, and MRI (floor of the mouth). All FDG PET/CTs were performed applying a flat table, head support and fixation mask as part of the radiotherapy treatment planning. Diagnostic CT with contrast was an integrated part of the PET/CT examination. Only 1/30 patients (cancer of the vallecula) had their primary cancer detected by FDG PET/CT. In addition, a non-biopsied patient with high uptake in the ipsilateral palatine tonsil was included, giving a detection rate of ≤7 % (95 % CI 2-21 %). In this retrospective study, we found that the FDG PET/CT detection rate of the primary for SCCUP patients is lower than previously reported. It is questionable whether FDG PET/CT is necessary for these patients when improved, advanced workup is available.
VirSSPA- a virtual reality tool for surgical planning workflow.
Suárez, C; Acha, B; Serrano, C; Parra, C; Gómez, T
2009-03-01
A virtual reality tool, called VirSSPA, was developed to optimize the planning of surgical processes. Segmentation algorithms for Computed Tomography (CT) images: a region growing procedure was used for soft tissues and a thresholding algorithm was implemented to segment bones. The algorithms operate semiautomati- cally since they only need seed selection with the mouse on each tissue segmented by the user. The novelty of the paper is the adaptation of an enhancement method based on histogram thresholding applied to CT images for surgical planning, which simplifies subsequent segmentation. A substantial improvement of the virtual reality tool VirSSPA was obtained with these algorithms. VirSSPA was used to optimize surgical planning, to decrease the time spent on surgical planning and to improve operative results. The success rate increases due to surgeons being able to see the exact extent of the patient's ailment. This tool can decrease operating room time, thus resulting in reduced costs. Virtual simulation was effective for optimizing surgical planning, which could, consequently, result in improved outcomes with reduced costs.
Ofori, Emmanuel; Then, Eric; John, Febin; Gaduputi, Vinaya
2018-01-01
Abstract Intramural duodenal hematoma (IDH) is a rare complication in endoscopic management of ulcer hemorrhage. Usually noted in cases of blunt abdominal trauma, non-traumatic IDHs have been reported in individuals on anticoagulation, with blood disorders, pancreatic diseases and in endoscopic procedures such as biopsy, sclerotherapy and argon plasma coagulation. Patients may be asymptomatic or present with acute blood loss anemia, abdominal pain or vomiting. We report a case of an 83-year-old man with melena and syncope who underwent endoscopy for bleeding ulcer control and subsequently developed acute pancreatitis due to an acute IDH. Computed tomography (CT) scan confirms the diagnosis. Most cases are conservatively managed however when unsuccessful, laparoscopic surgical drainage or ultrasound or CT guided drainage can be performed. PMID:29383264
Molecular imaging for theranostics in gastroenterology: one stone to kill two birds.
Ko, Kwang Hyun; Kown, Chang-Il; Park, Jong Min; Lee, Hoo Geun; Han, Na Young; Hahm, Ki Baik
2014-09-01
Molecular imaging in gastroenterology has become more feasible with recent advances in imaging technology, molecular genetics, and next-generation biochemistry, in addition to advances in endoscopic imaging techniques including magnified high-resolution endoscopy, narrow band imaging or autofluorescence imaging, flexible spectral imaging color enhancement, and confocal laser endomicroscopy. These developments have the potential to serve as "red flag" techniques enabling the earlier and accurate detection of mucosal abnormalities (such as precancerous lesions) beyond biomarkers, virtual histology of detected lesions, and molecular targeted therapy-the strategy of "one stone to kill two or three birds"; however, more effort should be done to be "blue ocean" benefit. This review deals with the introduction of Raman spectroscopy endoscopy, imaging mass spectroscopy, and nanomolecule development for theranostics. Imaging of molecular pathological changes in cells/tissues/organs might open the "royal road" to either convincing diagnosis of diseases that otherwise would only be detected in the advanced stages or novel therapeutic methods targeted to personalized medicine.
A Review of Endoscopic Simulation: Current Evidence on Simulators and Curricula.
King, Neil; Kunac, Anastasia; Merchant, Aziz M
2016-01-01
Upper and lower endoscopy is an important tool that is being utilized more frequently by general surgeons. Training in therapeutic endoscopic techniques has become a mandatory requirement for general surgery residency programs in the United States. The Fundamentals of Endoscopic Surgery has been developed to train and assess competency in these advanced techniques. Simulation has been shown to increase the skill and learning curve of trainees in other surgical disciplines. Several types of endoscopy simulators are commercially available; mechanical trainers, animal based, and virtual reality or computer-based simulators all have their benefits and limitations. However they have all been shown to improve trainee's endoscopic skills. Endoscopic simulators will play a critical role as part of a comprehensive curriculum designed to train the next generation of surgeons. We reviewed recent literature related to the various types of endoscopic simulators and their use in an educational curriculum, and discuss the relevant findings. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Creation of anatomical models from CT data
NASA Astrophysics Data System (ADS)
Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.
2018-04-01
Computed tomography is a great source of biomedical data because it allows a detailed exploration of complex anatomical structures. Some structures are not visible on CT scans, and some are hard to distinguish due to partial volume effect. CT datasets require preprocessing before using them as anatomical models in a simulation system. The work describes segmentation and data transformation methods for an anatomical model creation from the CT data. The result models may be used for visual and haptic rendering and drilling simulation in a virtual surgery system.
Kasaven, C P; McIntyre, G T; Mossey, P A
2017-01-01
Our objective was to assess the accuracy of virtual and printed 3-dimensional models derived from cone-beam computed tomographic (CT) scans to measure the volume of alveolar clefts before bone grafting. Fifteen subjects with unilateral cleft lip and palate had i-CAT cone-beam CT scans recorded at 0.2mm voxel and sectioned transversely into slices 0.2mm thick using i-CAT Vision. Volumes of alveolar clefts were calculated using first a validated algorithm; secondly, commercially-available virtual 3-dimensional model software; and finally 3-dimensional printed models, which were scanned with microCT and analysed using 3-dimensional software. For inter-observer reliability, a two-way mixed model intraclass correlation coefficient (ICC) was used to evaluate the reproducibility of identification of the cranial and caudal limits of the clefts among three observers. We used a Friedman test to assess the significance of differences among the methods, and probabilities of less than 0.05 were accepted as significant. Inter-observer reliability was almost perfect (ICC=0.987). There were no significant differences among the three methods. Virtual and printed 3-dimensional models were as precise as the validated computer algorithm in the calculation of volumes of the alveolar cleft before bone grafting, but virtual 3-dimensional models were the most accurate with the smallest 95% CI and, subject to further investigation, could be a useful adjunct in clinical practice. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Iacob, Razvan; Dimitriu, Anca; Stanciulea, Oana; Herlea, Vlad; Popescu, Irinel; Gheorghe, Cristian
2016-03-01
We present the case of a 63-year-old man that was admitted for melena and severe anemia. Upper GI endoscopy and colonoscopy failed to identify the lesion responsible for bleeding, and enteroCT scan was also non-contributive to the diagnosis. Capsule endoscopy indicated possible jejunal bleeding but could not indicate the source of bleeding, recommending anterograde enteroscopy. Single balloon enteroscopy identified a 2 cm submucosal tumour in the distal part of the jejunum, with a macroscopic appearance suggesting a gastrointestinal stromal tumour (GIST). The tumor location was marked using SPOT tattoo and subsequently easily identified by the surgeon and resected via minimally invasive laparoscopic-assisted approach. Histological and immunohistochemical analysis indicated a low risk GIST. The unusual small size of the GIST as a modality of presentation, with digestive bleeding and anemia and the ability to use VCE/enteroscopy to identify and mark the lesion prior to minimally invasive surgery, represent the particularities of the presented case.
Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).
Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B
2018-03-15
The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
Shao, Peng; Shi, Wei; Hajireza, Parsin; Zemp, Roger J
2012-07-01
We present a new integrated micro-endoscopy system combining label-free, fiber-based, real-time C-scan optical-resolution photoacoustic microscopy (F-OR-PAM) and a high-resolution fluorescence micro-endoscopy system for visualizing fluorescently labeled cellular components and optically absorbing microvasculature simultaneously. With a diode-pumped 532-nm fiber laser, the F-OR-PAM sub-system is able to reach a resolution of ∼7 μm. The fluorescence subsystem, which does not require any mechanical scanning, consists of a 447.5-nm-centered diode laser as the light source, an objective lens, and a CCD camera. Proflavine is used as the fluorescent contrast agent by topical application. The scanning laser and the diode laser light source share the same light path within an optical fiber bundle containing 30,000 individual single-mode fibers. The absorption of proflavine at 532 nm is low, which mitigates absorption bleaching of the contrast agent by the photoacoustic excitation source. We demonstrate imaging in live murine models. The system is able to provide cellular morphology with cellular resolution co-registered with the structural information given by F-OR-PAM. Therefore, the system has the potential to serve as a virtual biopsy technique, helping visualize angiogenesis and the effects of anti-cancer drugs on both cells and the microcirculation, as well as aid in the study of other diseases.
NASA Astrophysics Data System (ADS)
Shao, Peng; Shi, Wei; Hajireza, Parsin; Zemp, Roger J.
2012-07-01
We present a new integrated micro-endoscopy system combining label-free, fiber-based, real-time C-scan optical-resolution photoacoustic microscopy (F-OR-PAM) and a high-resolution fluorescence micro-endoscopy system for visualizing fluorescently labeled cellular components and optically absorbing microvasculature simultaneously. With a diode-pumped 532-nm fiber laser, the F-OR-PAM sub-system is able to reach a resolution of ~7 μm. The fluorescence subsystem, which does not require any mechanical scanning, consists of a 447.5-nm-centered diode laser as the light source, an objective lens, and a CCD camera. Proflavine is used as the fluorescent contrast agent by topical application. The scanning laser and the diode laser light source share the same light path within an optical fiber bundle containing 30,000 individual single-mode fibers. The absorption of proflavine at 532 nm is low, which mitigates absorption bleaching of the contrast agent by the photoacoustic excitation source. We demonstrate imaging in live murine models. The system is able to provide cellular morphology with cellular resolution co-registered with the structural information given by F-OR-PAM. Therefore, the system has the potential to serve as a virtual biopsy technique, helping visualize angiogenesis and the effects of anti-cancer drugs on both cells and the microcirculation, as well as aid in the study of other diseases.
Pessis, Eric; Campagna, Raphaël; Sverzut, Jean-Michel; Bach, Fabienne; Rodallec, Mathieu; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc
2013-01-01
With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.
Jacobson, Stanley; Epstein, Scott K; Albright, Susan; Ochieng, Joseph; Griffiths, Jeffrey; Coppersmith, Veronica; Polak, Joseph F
2009-08-01
The goal of this study was to determine whether computerized tomographic (CT) images of cadavers could be used in addition to images from patients to develop virtual patients (VPs) to enhance integrated learning of basic and clinical science. We imaged 13 cadavers on a Siemens CT system. The DICOM images from the CT were noted to be of high quality by a radiologist who systematically identified all abnormal and pathological findings. The pathological findings from the CT images and the cause of death were used to develop plausible clinical cases and study questions. Each case was designed to highlight and explain the abnormal anatomic findings encountered during the cadaveric dissection. A 3D reconstruction was produced using OsiriX and then formatted into a QuickTime movie which was then stored on the Tufts University Sciences Knowledgebase (TUSK) as a VP. We conclude that CT scanning of cadavers produces high-quality images that can be used to develop VPs. Although the use of the VPs was optional and fewer than half of the students had an imaged cadaver for dissection, 59 of the 172 (34%) students accessed and reviewed the cases and images positively and were very encouraging for us to continue.
Virtual reality in rhinology-a new dimension of clinical experience.
Klapan, Ivica; Raos, Pero; Galeta, Tomislav; Kubat, Goranka
2016-07-01
There is often a need to more precisely identify the extent of pathology and the fine elements of intracranial anatomic features during the diagnostic process and during many operations in the nose, sinus, orbit, and skull base region. In two case reports, we describe the methods used in the diagnostic workup and surgical therapy in the nose and paranasal sinus region. Besides baseline x-ray, multislice computed tomography, and magnetic resonance imaging, operative field imaging was performed via a rapid prototyping model, virtual endoscopy, and 3-D imaging. Different head tissues were visualized in different colors, showing their anatomic interrelations and the extent of pathologic tissue within the operative field. This approach has not yet been used as a standard preoperative or intraoperative procedure in otorhinolaryngology. In this way, we tried to understand the new, visualized "world of anatomic relations within the patient's head" by creating an impression of perception (virtual perception) of the given position of all elements in a particular anatomic region of the head, which does not exist in the real world (virtual world). This approach was aimed at upgrading the diagnostic workup and surgical therapy by ensuring a faster, safer and, above all, simpler operative procedure. In conclusion, any ENT specialist can provide virtual reality support in implementing surgical procedures, with additional control of risks and within the limits of normal tissue, without additional trauma to the surrounding tissue in the anatomic region. At the same time, the virtual reality support provides an impression of the virtual world as the specialist navigates through it and manipulates virtual objects.
Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T
2018-04-17
Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.
Neuhaus, Victor; Große Hokamp, Nils; Abdullayev, Nuran; Maus, Volker; Kabbasch, Christoph; Mpotsaris, Anastasios; Maintz, David; Borggrefe, Jan
2018-03-01
To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA). Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance. Compared to polyenergetic images, although noise increased with lower keV, CNR (p < 0.02) and SNR (p > 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p < 0.0001 each). Compared to polyenergetic images, virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches. • Virtual monoenergetic images greatly improve attenuation, while noise only slightly increases. • Virtual monoenergetic images show superior contrast-to-noise ratios compared to polyenergetic images. • Virtual monoenergetic images significantly improve image quality at low keV.
Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)
NASA Astrophysics Data System (ADS)
Ding, Aiping
X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this software provides a better CT dose assessment by using anatomically realistic patient phantoms. All the related organ doses are incorporated into a standardized database compiled using Microsoft Structured Query Language (SQL) server 2008. Organ doses from contiguous axial or helical scans defined by a specific protocol can be rapidly obtained from the database. A next-generation software architecture and Active Server Pages (ASP) .NET framework are adopted to create a browser-hosted application to improve the user interactivity and reporting functionality including scanning parameter selection and organ dose reporting. “VirtualDose” has been developed as a web-based CT dose reporting platform to facilitate several important features including: (1) easy access via Internet; (2) no need for installation on the local computer; (3) a user-friendly, dynamic, browser-hosted graphical user interface; (4) use of advanced patient models for the adult male and female, pregnant women, children, and obese patient models; (5) adoption of modern CT scanners and protocols, as well as the most recent ICRP 103 effective dose algorithms; and (6) flexibility to manage and easily upgrade without impacting user’s usage.
Francis, I C; Kappagoda, M B; Cole, I E; Bank, L; Dunn, G D
1999-05-01
To evaluate the role of computed tomography in patients with dacryostenosis. One hundred seven cases of dacryostenosis (94 patients) were assessed by thorough clinical and lacrimal history and examination, and lacrimal region computerized tomography (CT). The lacrimal drainage system examination included the state and position of the puncta; Jones testing; lacrimal syringing; and, in the latter half of the study, telescopic nasal endoscopy. The patients were drawn from the hospital outpatients and private office of the operating lacrimal surgeon in this series (I.C.F.). Of the 107 cases, 79 either underwent dacryocystorhinostomy surgery or had this planned. In 14 of the 107 cases (12 patients), preoperative CT led to an alteration of patient management, usually referral to an otolaryngologist for further evaluation or treatment. In addition to the detection of two tumors extrinsic to the sac, conditions such as ethmoiditis, lacrimal sac mucoceles, soft tissue opacity in the nasolacrimal duct, gross nasal polyposis, fungal sinusitis, and a dacryolith were observed by CT. Similar to the role of functional endoscopic sinus surgery in otolaryngology, CT imaging will become increasingly important in the assessment of many patients with symptoms of lacrimal drainage obstruction.
New tools for sculpting cranial implants in a shared haptic augmented reality environment.
Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary
2006-01-01
New volumetric tools were developed for the design and fabrication of high quality cranial implants from patient CT data. These virtual tools replace time consuming physical sculpting, mold making and casting steps. The implant is designed by medical professionals in tele-immersive collaboration. Virtual clay is added in the virtual defect area on the CT data using the adding tool. With force feedback the modeler can feel the edge of the defect and fill only the space where no bone is present. A carving tool and a smoothing tool are then used to sculpt and refine the implant. To make a physical evaluation, the skull with simulated defect and the implant are fabricated via stereolithography to allow neurosurgeons to evaluate the quality of the implant. Initial tests demonstrate a very high quality fit. These new haptic volumetric sculpting tools are a critical component of a comprehensive tele-immersive system.
Feasibility of dual-energy computed tomography in radiation therapy planning
NASA Astrophysics Data System (ADS)
Sheen, Heesoon; Shin, Han-Back; Cho, Sungkoo; Cho, Junsang; Han, Youngyih
2017-12-01
In this study, the noise level, effective atomic number ( Z eff), accuracy of the computed tomography (CT) number, and the CT number to the relative electron density EDconversion curve were estimated for virtual monochromatic energy and polychromatic energy. These values were compared to the theoretically predicted values to investigate the feasibility of the use of dual-energy CT in routine radiation therapy planning. The accuracies of the parameters were within the range of acceptability. These results can serve as a stepping stone toward the routine use of dual-energy CT in radiotherapy planning.
Yanagiya, Masahiro; Matsumoto, Jun; Nagano, Masaaki; Kusakabe, Masashi; Matsumoto, Yoko; Furukawa, Ryutaro; Ohara, Sayaka; Usui, Kazuhiro
2018-01-01
Abstract Rationale: The development of postoperative bronchopleural fistula (BPF) remains a challenge in thoracic surgery. We herein report a case of BPF successfully treated with endoscopic bronchial occlusion under computed tomography (CT) fluoroscopy and virtual bronchoscopic navigation (VBN). Patient concerns: A 63-year-old man underwent right upper lobectomy with concomitant S6a subsegmentectomy for lung adenocarcinoma. On postoperative day 24, he complained of shaking chills with high fever. Diagnoses: BPF with subsequent pneumonia and empyema. Interventions: Despite aggressive surgical interventions for the BPF, air leakage persisted postoperatively. On days 26 and 34 after the final operation, endobronchial occlusions were performed under CT fluoroscopy and VBN. Outcomes: The air leaks greatly decreased and the patient was discharged. Lessons: CT fluoroscopy and VBN can be useful techniques for endobronchial occlusion in the treatment of BPF. PMID:29443771
Shin, Eun Kyung; Moon, Won; Park, Seun Ja; Park, Moo In; Kim, Kyu Jong; Lee, Jee Suk; Kwon, Jin Hwan
2009-03-21
Congenital absence of the splenic artery is a very rare condition. To the best of our knowledge, congenital absence of the splenic artery accompanied with absence of the splenic vein has not been reported. We report a case of the absence of the splenic artery and vein in a 61-year-old woman who presented with postprandial epigastric discomfort. Upper gastrointestinal endoscopy showed a dilated, pulsatile vessel in the fundus and duodenal stenosis. An abdominal computed tomography (CT) scan revealed absence of the splenic vein with a tortuously engorged gastroepiploic vein. Three-dimensional CT demonstrated the tortuously dilated left gastric artery and the left gastroepiploic artery with non-visualization of the splenic artery. After administration of a proton pump inhibitor, abdominal symptoms resolved without any recurrence of symptoms during 6 mo of follow-up.
Liquid Biopsy: A Future Tool for Posttreatment Surveillance in Head and Neck Cancer?
van Ginkel, Joost H; Huibers, Manon M H; Noorlag, Rob; de Bree, Remco; van Es, Robert J J; Willems, Stefan M
2017-01-01
The prognosis of head and neck squamous cell carcinoma (HNSCC) is largely based on disease stage. Despite improvements in treatment, recurrence rates are still considered high. Currently, disease progression or regression after curative treatment is monitored by clinical evaluation combined with flexible endoscopy and/or imaging. However, specificity of imaging is low due to the posttreatment effects. Detection of circulating tumor DNA (ctDNA) from blood samples of HNSCC patients is a minimally invasive technique that could lead to an earlier detection of recurrence. In addition, digital droplet PCR (ddPCR) could be used to sensitively detect these mutational targets. Future study on ctDNA using ddPCR in blood samples of HNSCC patients is recommended during the follow-up stage to detect recurrences in a timely manner. © 2016 S. Karger AG, Basel.
ERIC Educational Resources Information Center
Mukherjee, Maheswari S.
2012-01-01
Traditionally, cytotechnology (CT) students have been trained by using light microscopy (LM) and glass slides. However, this method of training has some drawbacks. Several other educational programs with similar issues have incorporated virtual microscopy (VM) in their curricula. In VM, the specimens on glass slides are converted into virtual…
Prior image constrained image reconstruction in emerging computed tomography applications
NASA Astrophysics Data System (ADS)
Brunner, Stephen T.
Advances have been made in computed tomography (CT), especially in the past five years, by incorporating prior images into the image reconstruction process. In this dissertation, we investigate prior image constrained image reconstruction in three emerging CT applications: dual-energy CT, multi-energy photon-counting CT, and cone-beam CT in image-guided radiation therapy. First, we investigate the application of Prior Image Constrained Compressed Sensing (PICCS) in dual-energy CT, which has been called "one of the hottest research areas in CT." Phantom and animal studies are conducted using a state-of-the-art 64-slice GE Discovery 750 HD CT scanner to investigate the extent to which PICCS can enable radiation dose reduction in material density and virtual monochromatic imaging. Second, we extend the application of PICCS from dual-energy CT to multi-energy photon-counting CT, which has been called "one of the 12 topics in CT to be critical in the next decade." Numerical simulations are conducted to generate multiple energy bin images for a photon-counting CT acquisition and to investigate the extent to which PICCS can enable radiation dose efficiency improvement. Third, we investigate the performance of a newly proposed prior image constrained scatter correction technique to correct scatter-induced shading artifacts in cone-beam CT, which, when used in image-guided radiation therapy procedures, can assist in patient localization, and potentially, dose verification and adaptive radiation therapy. Phantom studies are conducted using a Varian 2100 EX system with an on-board imager to investigate the extent to which the prior image constrained scatter correction technique can mitigate scatter-induced shading artifacts in cone-beam CT. Results show that these prior image constrained image reconstruction techniques can reduce radiation dose in dual-energy CT by 50% in phantom and animal studies in material density and virtual monochromatic imaging, can lead to radiation dose efficiency improvement in multi-energy photon-counting CT, and can mitigate scatter-induced shading artifacts in cone-beam CT in full-fan and half-fan modes.
Immersive virtual reality for visualization of abdominal CT
NASA Astrophysics Data System (ADS)
Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.
2013-03-01
Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.
Immersive Virtual Reality for Visualization of Abdominal CT.
Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E
2013-03-28
Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.
Fischer, Georg; Liu, Cong; Audisio, Tracy L.; Alpert, Gary D.; Fisher, Brian L.; Economo, Evan P.
2017-01-01
We explore the potential of x-ray micro computed tomography (μCT) for the field of ant taxonomy by using it to enhance the descriptions of two remarkable new species of the ant genus Terataner: T. balrog sp. n. and T. nymeria sp. n.. We provide an illustrated worker-based species identification key for all species found on Madagascar, as well as detailed taxonomic descriptions, which include diagnoses, discussions, measurements, natural history data, high-quality montage images and distribution maps for both new species. In addition to conventional morphological examination, we have used virtual reconstructions based on volumetric μCT scanning data for the species descriptions. We also include 3D PDFs, still images of virtual reconstructions, and 3D rotation videos for both holotype workers and one paratype queen. The complete μCT datasets have been made available online (Dryad, https://datadryad.org) and represent the first cybertypes in ants (and insects). We discuss the potential of μCT scanning and critically assess the usefulness of cybertypes for ant taxonomy. PMID:28328931
NASA Astrophysics Data System (ADS)
Wang, Jing; Wang, Su; Li, Lihong; Fan, Yi; Lu, Hongbing; Liang, Zhengrong
2008-10-01
Computed tomography colonography (CTC) or CT-based virtual colonoscopy (VC) is an emerging tool for detection of colonic polyps. Compared to the conventional fiber-optic colonoscopy, VC has demonstrated the potential to become a mass screening modality in terms of safety, cost, and patient compliance. However, current CTC delivers excessive X-ray radiation to the patient during data acquisition. The radiation is a major concern for screening application of CTC. In this work, we performed a simulation study to demonstrate a possible ultra low-dose CT technique for VC. The ultra low-dose abdominal CT images were simulated by adding noise to the sinograms of the patient CTC images acquired with normal dose scans at 100 mA s levels. The simulated noisy sinogram or projection data were first processed by a Karhunen-Loeve domain penalized weighted least-squares (KL-PWLS) restoration method and then reconstructed by a filtered backprojection algorithm for the ultra low-dose CT images. The patient-specific virtual colon lumen was constructed and navigated by a VC system after electronic colon cleansing of the orally-tagged residue stool and fluid. By the KL-PWLS noise reduction, the colon lumen can successfully be constructed and the colonic polyp can be detected in an ultra low-dose level below 50 mA s. Polyp detection can be found more easily by the KL-PWLS noise reduction compared to the results using the conventional noise filters, such as Hanning filter. These promising results indicate the feasibility of an ultra low-dose CTC pipeline for colon screening with less-stressful bowel preparation by fecal tagging with oral contrast.
Danz, J C; Habegger, M; Bosshardt, D D; Katsaros, C; Stavropoulos, A
2014-01-01
Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right–left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland–Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed. PMID:24266502
Chinnadurai, Ponraj; Duran, Cassidy; Al-Jabbari, Odeaa; Abu Saleh, Walid K; Lumsden, Alan; Bismuth, Jean
2016-01-01
To report our initial experience and highlight the value of using intraoperative C-arm cone beam computed tomography (CT; DynaCT(®)) image fusion guidance along with steerable robotic endovascular catheter navigation to optimize vessel cannulation. Between May 2013 and January 2015, all patients who underwent endovascular procedures using DynaCT image fusion technique along with Hansen Magellan vascular robotic catheter were included in this study. As a part of preoperative planning, relevant vessel landmarks were electronically marked in contrast-enhanced multi-slice computed tomography images and stored. At the beginning of procedure, an intraoperative noncontrast C-arm cone beam CT (syngo DynaCT(®), Siemens Medical Solutions USA Inc.) was acquired in the hybrid suite. Preoperative images were then coregistered to intraoperative DynaCT images using aortic wall calcifications and bone landmarks. Stored landmarks were then overlaid on 2-dimensional (2D) live fluoroscopic images as virtual markers that are updated in real-time with C-arm, table movements and image zoom. Vascular access and robotic catheter (Magellan(®), Hansen Medical) was setup per standard. Vessel cannulation was performed based on electronic virtual markers on live fluoroscopy using robotic catheter. The impact of 3-dimensional (3D) image fusion guidance on robotic vessel cannulation was evaluated retrospectively, by assessing quantitative parameters like number of angiograms acquired before vessel cannulation and qualitative parameters like accuracy of vessel ostium and centerline markers. All 17 vessels were cannulated successfully in 14 patients' attempted using robotic catheter and image fusion guidance. Median vessel diameter at origin was 5.4 mm (range, 2.3-13 mm), whereas 12 of 17 (70.6%) vessels had either calcified and/or stenosed origin from parent vessel. Nine of 17 vessels (52.9 %) were cannulated without any contrast injection. Median number of angiograms required before cannulation was 0 (range, 0-2). On qualitative assessment, 14 of 15 vessels (93.3%) had grade = 1 accuracy (guidewire inside virtual ostial marker). Fourteen of 14 vessels had grade = 1 accuracy (virtual centerlines that matched with the actual vessel trajectory during cannulation). In this small series, the experience of using DynaCT image fusion guidance together with a steerable endovascular robotic catheter indicates that such image fusion strategies can enhance intraoperative 2D fluoroscopy by bringing preoperative 3D information about vascular stenosis and/or calcification, angulation, and take off from main vessel thereby facilitating ultimate vessel cannulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Application of fluence field modulation to proton computed tomography for proton therapy imaging.
Dedes, G; De Angelis, L; Rit, S; Hansen, D; Belka, C; Bashkirov, V; Johnson, R P; Coutrakon, G; Schubert, K E; Schulte, R W; Parodi, K; Landry, G
2017-07-12
This simulation study presents the application of fluence field modulated computed tomography, initially developed for x-ray CT, to proton computed tomography (pCT). By using pencil beam (PB) scanning, fluence modulated pCT (FMpCT) may achieve variable image quality in a pCT image and imaging dose reduction. Three virtual phantoms, a uniform cylinder and two patients, were studied using Monte Carlo simulations of an ideal list-mode pCT scanner. Regions of interest (ROI) were selected for high image quality and only PBs intercepting them preserved full fluence (FF). Image quality was investigated in terms of accuracy (mean) and noise (standard deviation) of the reconstructed proton relative stopping power compared to reference values. Dose calculation accuracy on FMpCT images was evaluated in terms of dose volume histograms (DVH), range difference (RD) for beam-eye-view (BEV) dose profiles and gamma evaluation. Pseudo FMpCT scans were created from broad beam experimental data acquired with a list-mode pCT prototype. FMpCT noise in ROIs was equivalent to FF images and accuracy better than -1.3%(-0.7%) by using 1% of FF for the cylinder (patients). Integral imaging dose reduction of 37% and 56% was achieved for the two patients for that level of modulation. Corresponding DVHs from proton dose calculation on FMpCT images agreed to those from reference images and 96% of BEV profiles had RD below 2 mm, compared to only 1% for uniform 1% of FF. Gamma pass rates (2%, 2 mm) were 98% for FMpCT while for uniform 1% of FF they were as low as 59%. Applying FMpCT to preliminary experimental data showed that low noise levels and accuracy could be preserved in a ROI, down to 30% modulation. We have shown, using both virtual and experimental pCT scans, that FMpCT is potentially feasible and may allow a means of imaging dose reduction for a pCT scanner operating in PB scanning mode. This may be of particular importance to proton therapy given the low integral dose found outside the target.
Colonoscope navigation system using colonoscope tracking method based on line registration
NASA Astrophysics Data System (ADS)
Oda, Masahiro; Kondo, Hiroaki; Kitasaka, Takayuki; Furukawa, Kazuhiro; Miyahara, Ryoji; Hirooka, Yoshiki; Goto, Hidemi; Navab, Nassir; Mori, Kensaku
2014-03-01
This paper presents a new colonoscope navigation system. CT colonography is utilized for colon diagnosis based on CT images. If polyps are found while CT colonography, colonoscopic polypectomy can be performed to remove them. While performing a colonoscopic examination, a physician controls colonoscope based on his/her experience. Inexperienced physicians may occur complications such as colon perforation while colonoscopic examinations. To reduce complications, a navigation system of colonoscope while performing the colonoscopic examinations is necessary. We propose a colonoscope navigation system. This system has a new colonoscope tracking method. This method obtains a colon centerline from a CT volume of a patient. A curved line (colonoscope line) representing the shape of colonoscope inserted to the colon is obtained by using electromagnetic sensors. A coordinate system registration process that employs the ICP algorithm is performed to register the CT and sensor coordinate systems. The colon centerline and colonoscope line are registered by using a line registration method. The position of the colonoscope tip in the colon is obtained from the line registration result. Our colonoscope navigation system displays virtual colonoscopic views generated from the CT volumes. A viewpoint of the virtual colonoscopic view is a point on the centerline that corresponds to the colonoscope tip. Experimental results using a colon phantom showed that the proposed colonoscope tracking method can track the colonoscope tip with small tracking errors.
Reanimating patients: cardio-respiratory CT and MR motion phantoms based on clinical CT patient data
NASA Astrophysics Data System (ADS)
Mayer, Johannes; Sauppe, Sebastian; Rank, Christopher M.; Sawall, Stefan; Kachelrieß, Marc
2017-03-01
Until today several algorithms have been developed that reduce or avoid artifacts caused by cardiac and respiratory motion in computed tomography (CT). The motion information is converted into so-called motion vector fields (MVFs) and used for motion compensation (MoCo) during the image reconstruction. To analyze these algorithms quantitatively there is the need for ground truth patient data displaying realistic motion. We developed a method to generate a digital ground truth displaying realistic cardiac and respiratory motion that can be used as a tool to assess MoCo algorithms. By the use of available MoCo methods we measured the motion in CT scans with high spatial and temporal resolution and transferred the motion information onto patient data with different anatomy or imaging modality, thereby reanimating the patient virtually. In addition to these images the ground truth motion information in the form of MVFs is available and can be used to benchmark the MVF estimation of MoCo algorithms. We here applied the method to generate 20 CT volumes displaying detailed cardiac motion that can be used for cone-beam CT (CBCT) simulations and a set of 8 MR volumes displaying respiratory motion. Our method is able to reanimate patient data virtually. In combination with the MVFs it serves as a digital ground truth and provides an improved framework to assess MoCo algorithms.
Mangold, Stefanie; Thomas, Christoph; Fenchel, Michael; Vuust, Morten; Krauss, Bernhard; Ketelsen, Dominik; Tsiflikas, Ilias; Claussen, Claus D; Heuschmid, Martin
2012-07-01
To retrospectively determine which features of urinary calculi are associated with their detection after virtual elimination of contrast medium at dual-energy computed tomographic (CT) urography by using a novel tin filter. The institutional ethics committee approved this retrospective study, with waiver of informed consent. A total of 152 patients were examined with single-energy nonenhanced CT and dual-energy CT urography in the excretory phase (either 140 and 80 kV [n=44] or 140 and 100 kV [n=108], with tin filtration at 140 kV). The contrast medium in the renal pelvis and ureters was virtually removed from excretory phase images by using postprocessing software, resulting in virtual nonenhanced (VNE) images. The sensitivity regarding the detection of calculi on VNE images compared with true nonenhanced (TNE) images was determined, and interrater agreement was evaluated by using the Cohen k test. By using logistic regression, the influences of image noise, attenuation, and stone size, as well as attenuation of the contrast medium, on the stone detection rate were assessed. Threshold values with maximal sensitivity and specificity were calculated by means of receiver operating characteristic analyses. Eighty-seven stones were detected on TNE images; 46 calculi were identified on VNE images (sensitivity, 52.9%). Interrater agreement revealed a κ value of 0.95 with TNE images and 0.91 with VNE data. Size (long-axis diameter, P=.005; short-axis diameter, P=.041) and attenuation (P=.0005) of the calculi and image noise (P=.0031) were significantly associated with the detection rate on VNE images. As threshold values, size larger than 2.9 mm, maximum attenuation of the calculi greater than 387 HU, and image noise less than 20 HU were found. After virtual elimination of contrast medium, large (>2.9 mm) and high-attenuation (>387 HU) calculi can be detected with good reliability; smaller and lower attenuation calculi might be erased from images, especially with increased image noise. © RSNA, 2012.
Narita, Akihiro; Ohkubo, Masaki; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi
2017-10-01
The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Good agreement of the virtual nodules generated from the nodule-like object functions A and B of the phantom spheres was found, suggesting the validity of the nodule-like object functions. The virtual nodules generated from the nodule-like object function A of the phantom spheres were similar to the real images obtained with Scanner C; the root mean square errors (RMSEs) between them were 10.8, 11.1, and 12.5 Hounsfield units (HU) for 5-, 7-, and 10-mm-diameter spheres, respectively. The equivalent results (RMSEs) using the nodule-like object function B were 15.9, 16.8, and 16.5 HU, respectively. These RMSEs were small considering the high contrast between the sphere density and background density (approximately 674 HU). The virtual nodules generated from the nodule-like object functions of the five laboratory-made nodules were similar to the real images obtained with Scanner C; the RMSEs between them ranged from 6.2 to 8.6 HU in five cases. The nodule-like object functions calculated from real nodule images would be effective to generate realistic virtual nodules. The proposed method would be feasible for generating virtual nodules that have the characteristics of the spatial resolution of the CT system used in each institution, allowing for site-specific nodule generation. © 2017 American Association of Physicists in Medicine.
Visualization and simulation techniques for surgical simulators using actual patient's data.
Radetzky, Arne; Nürnberger, Andreas
2002-11-01
Because of the increasing complexity of surgical interventions research in surgical simulation became more and more important over the last years. However, the simulation of tissue deformation is still a challenging problem, mainly due to the short response times that are required for real-time interaction. The demands to hard and software are even larger if not only the modeled human anatomy is used but the anatomy of actual patients. This is required if the surgical simulator should be used as training medium for expert surgeons rather than students. In this article, suitable visualization and simulation methods for surgical simulation utilizing actual patient's datasets are described. Therefore, the advantages and disadvantages of direct and indirect volume rendering for the visualization are discussed and a neuro-fuzzy system is described, which can be used for the simulation of interactive tissue deformations. The neuro-fuzzy system makes it possible to define the deformation behavior based on a linguistic description of the tissue characteristics or to learn the dynamics by using measured data of real tissue. Furthermore, a simulator for minimally-invasive neurosurgical interventions is presented that utilizes the described visualization and simulation methods. The structure of the simulator is described in detail and the results of a system evaluation by an experienced neurosurgeon--a quantitative comparison between different methods of virtual endoscopy as well as a comparison between real brain images and virtual endoscopies--are given. The evaluation proved that the simulator provides a higher realism of the visualization and simulation then other currently available simulators. Copyright 2002 Elsevier Science B.V.
The Delivery of Business Courses via the African Virtual University: A Case Study
ERIC Educational Resources Information Center
Graber, Mark; Bolt, Susan
2011-01-01
In this case study the delivery of business courses as a result of the partnership between the African Virtual University (AVU) and Curtin University in Western Australia is described. From 2004 to 2008, degree and diploma business courses were delivered using WebCT in the four AVU partner locations: Addis Ababa University (Ethiopia), Kigali…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montoya, J; Ferrero, A; Yu, L
Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150more » and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.« less
Franco, Ademir; Thevissen, Patrick; Coudyzer, Walter; Develter, Wim; Van de Voorde, Wim; Oyen, Raymond; Vandermeulen, Dirk; Jacobs, Reinhilde; Willems, Guy
2013-05-01
Virtual autopsy is a medical imaging technique, using full body computed tomography (CT), allowing for a noninvasive and permanent observation of all body parts. For dental identification clinically and radiologically observed ante-mortem (AM) and post-mortem (PM) oral identifiers are compared. The study aimed to verify if a PM dental charting can be performed on virtual reconstructions of full-body CT's using the Interpol dental codes. A sample of 103 PM full-body CT's was collected from the forensic autopsy files of the Department of Forensic Medicine University Hospitals, KU Leuven, Belgium. For validation purposes, 3 of these bodies underwent a complete dental autopsy, a dental radiological and a full-body CT examination. The bodies were scanned in a Siemens Definition Flash CT Scanner (Siemens Medical Solutions, Germany). The images were examined on 8- and 12-bit screen resolution as three-dimensional (3D) reconstructions and as axial, coronal and sagittal slices. InSpace(®) (Siemens Medical Solutions, Germany) software was used for 3D reconstruction. The dental identifiers were charted on pink PM Interpol forms (F1, F2), using the related dental codes. Optimal dental charting was obtained by combining observations on 3D reconstructions and CT slices. It was not feasible to differentiate between different kinds of dental restoration materials. The 12-bit resolution enabled to collect more detailed evidences, mainly related to positions within a tooth. Oral identifiers, not implemented in the Interpol dental coding were observed. Amongst these, the observed (3D) morphological features of dental and maxillofacial structures are important identifiers. The latter can become particularly more relevant towards the future, not only because of the inherent spatial features, yet also because of the increasing preventive dental treatment, and the decreasing application of dental restorations. In conclusion, PM full-body CT examinations need to be implemented in the PM dental charting protocols and the Interpol dental codes should be adapted accordingly. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Augmented virtuality for arthroscopic knee surgery.
Li, John M; Bardana, Davide D; Stewart, A James
2011-01-01
This paper describes a computer system to visualize the location and alignment of an arthroscope using augmented virtuality. A 3D computer model of the patient's joint (from CT) is shown, along with a model of the tracked arthroscopic probe and the projection of the camera image onto the virtual joint. A user study, using plastic bones instead of live patients, was made to determine the effectiveness of this navigated display; the study showed that the navigated display improves target localization in novice residents.
Implementation of real-time digital endoscopic image processing system
NASA Astrophysics Data System (ADS)
Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho
1997-10-01
Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.
Advanced Imaging Technologies for the Detection of Dysplasia and Early Cancer in Barrett Esophagus
Espino, Alberto; Cirocco, Maria; DaCosta, Ralph
2014-01-01
Advanced esophageal adenocarcinomas arising from Barrett esophagus (BE) are tumors with an increasing incidence and poor prognosis. The aim of endoscopic surveillance of BE is to detect dysplasia, particularly high-grade dysplasia and intramucosal cancers that can subsequently be treated endoscopically before progression to invasive cancer with lymph node metastases. Current surveillance practice standards require the collection of random 4-quadrant biopsy specimens over every 1 to 2 cm of BE (Seattle protocol) to detect dysplasia with the assistance of white light endoscopy, in addition to performing targeted biopsies of recognizable lesions. This approach is labor-intensive but should currently be considered state of the art. Chromoendoscopy, virtual chromoendoscopy (e.g., narrow band imaging), and confocal laser endomicroscopy, in addition to high-definition standard endoscopy, might increase the diagnostic yield for the detection of dysplastic lesions. Until these modalities have been demonstrated to enhance efficiency or cost effectiveness, the standard protocol will remain careful examination using conventional off the shelf high-resolution endoscopes, combined with as longer inspection time which is associated with increased detection of dysplasia. PMID:24570883
NASA Astrophysics Data System (ADS)
Abadi, Ehsan; Sturgeon, Gregory M.; Agasthya, Greeshma; Harrawood, Brian; Hoeschen, Christoph; Kapadia, Anuj; Segars, W. P.; Samei, Ehsan
2017-03-01
This study aimed to model virtual human lung phantoms including both non-parenchymal and parenchymal structures. Initial branches of the non-parenchymal structures (airways, arteries, and veins) were segmented from anatomical data in each lobe separately. A volume-filling branching algorithm was utilized to grow the higher generations of the airways and vessels to the level of terminal branches. The diameters of the airways and vessels were estimated using established relationships between flow rates and diameters. The parenchyma was modeled based on secondary pulmonary lobule units. Polyhedral shapes with variable sizes were modeled, and the borders were assigned to interlobular septa. A heterogeneous background was added inside these units using a non-parametric texture synthesis algorithm which was informed by a high-resolution CT lung specimen dataset. A voxelized based CT simulator was developed to create synthetic helical CT images of the phantom with different pitch values. Results showed the progressive degradation in depiction of lung details with increased pitch. Overall, the enhanced lung models combined with the XCAT phantoms prove to provide a powerful toolset to perform virtual clinical trials in the context of thoracic imaging. Such trials, not practical using clinical datasets or simplistic phantoms, can quantitatively evaluate and optimize advanced imaging techniques towards patient-based care.
Identification of chronic rhinosinusitis phenotypes using cluster analysis.
Soler, Zachary M; Hyer, J Madison; Ramakrishnan, Viswanathan; Smith, Timothy L; Mace, Jess; Rudmik, Luke; Schlosser, Rodney J
2015-05-01
Current clinical classifications of chronic rhinosinusitis (CRS) have been largely defined based upon preconceived notions of factors thought to be important, such as polyp or eosinophil status. Unfortunately, these classification systems have little correlation with symptom severity or treatment outcomes. Unsupervised clustering can be used to identify phenotypic subgroups of CRS patients, describe clinical differences in these clusters and define simple algorithms for classification. A multi-institutional, prospective study of 382 patients with CRS who had failed initial medical therapy completed the Sino-Nasal Outcome Test (SNOT-22), Rhinosinusitis Disability Index (RSDI), Medical Outcomes Study Short Form-12 (SF-12), Pittsburgh Sleep Quality Index (PSQI), and Patient Health Questionnaire (PHQ-2). Objective measures of CRS severity included Brief Smell Identification Test (B-SIT), CT, and endoscopy scoring. All variables were reduced and unsupervised hierarchical clustering was performed. After clusters were defined, variations in medication usage were analyzed. Discriminant analysis was performed to develop a simplified, clinically useful algorithm for clustering. Clustering was largely determined by age, severity of patient reported outcome measures, depression, and fibromyalgia. CT and endoscopy varied somewhat among clusters. Traditional clinical measures, including polyp/atopic status, prior surgery, B-SIT and asthma, did not vary among clusters. A simplified algorithm based upon productivity loss, SNOT-22 score, and age predicted clustering with 89% accuracy. Medication usage among clusters did vary significantly. A simplified algorithm based upon hierarchical clustering is able to classify CRS patients and predict medication usage. Further studies are warranted to determine if such clustering predicts treatment outcomes. © 2015 ARS-AAOA, LLC.
Wichmann, D; Heinemann, A; Zähler, S; Vogel, H; Höpker, W; Püschel, K; Kluge, S
2018-06-01
There has been increasing use of invasive techniques, such as extracorporeal organ support, in intensive care units (ICU), and declining autopsy rates. Thus, new measures are needed to maintain high-quality standards. We investigated the potential of computed tomography (CT)-based virtual autopsy to substitute for medical autopsy in this setting. We investigated the potential of virtual autopsy by post-mortem CT to identify complications associated with medical devices in a prospective study of patients who had died in the ICU. Clinical records were reviewed to determine the number and types of medical devices used, and findings from medical and virtual autopsies, related and unrelated to the medical devices, were compared. Medical and virtual autopsies could be performed in 61 patients (Group M/V), and virtual autopsy only in 101 patients (Group V). In Group M/V, 41 device-related complications and 30 device malpositions were identified, but only with a low inter-method agreement. Major findings unrelated to a device were identified in about 25% of patients with a high level of agreement between methods. In Group V, 8 device complications and 36 device malpositions were identified. Device-related complications are frequent in ICU patients. Virtual and medical autopsies showed clear differences in the detection of complications and device malpositions. Both methods should supplement each other rather than one alone for quality control of medical devices in the ICU. Further studies should focus on the identification of special patient populations in which virtual autopsy might be of particular benefit. NCT01541982. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain
2017-08-01
Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Traversing and labeling interconnected vascular tree structures from 3D medical images
NASA Astrophysics Data System (ADS)
O'Dell, Walter G.; Govindarajan, Sindhuja Tirumalai; Salgia, Ankit; Hegde, Satyanarayan; Prabhakaran, Sreekala; Finol, Ender A.; White, R. James
2014-03-01
Purpose: Detailed characterization of pulmonary vascular anatomy has important applications for the diagnosis and management of a variety of vascular diseases. Prior efforts have emphasized using vessel segmentation to gather information on the number or branches, number of bifurcations, and branch length and volume, but accurate traversal of the vessel tree to identify and repair erroneous interconnections between adjacent branches and neighboring tree structures has not been carefully considered. In this study, we endeavor to develop and implement a successful approach to distinguishing and characterizing individual vascular trees from among a complex intermingling of trees. Methods: We developed strategies and parameters in which the algorithm identifies and repairs false branch inter-tree and intra-tree connections to traverse complicated vessel trees. A series of two-dimensional (2D) virtual datasets with a variety of interconnections were constructed for development, testing, and validation. To demonstrate the approach, a series of real 3D computed tomography (CT) lung datasets were obtained, including that of an anthropomorphic chest phantom; an adult human chest CT; a pediatric patient chest CT; and a micro-CT of an excised rat lung preparation. Results: Our method was correct in all 2D virtual test datasets. For each real 3D CT dataset, the resulting simulated vessel tree structures faithfully depicted the vessel tree structures that were originally extracted from the corresponding lung CT scans. Conclusion: We have developed a comprehensive strategy for traversing and labeling interconnected vascular trees and successfully implemented its application to pulmonary vessels observed using 3D CT images of the chest.
Implementation of a virtual laryngoscope system using efficient reconstruction algorithms.
Luo, Shouhua; Yan, Yuling
2009-08-01
Conventional fiberoptic laryngoscope may cause discomfort to the patient and in some cases it can lead to side effects that include perforation, infection and hemorrhage. Virtual laryngoscopy (VL) can overcome this problem and further it may lower the risk of operation failures. Very few virtual endoscope (VE) based investigations of the larynx have been described in the literature. CT data sets from a healthy subject were used for the VL studies. An algorithm of preprocessing and region-growing for 3-D image segmentation is developed. An octree based approach is applied in our VL system which facilitates a rapid construction of iso-surfaces. Some locating techniques are used for fast rendering and navigation (fly-through). Our VL visualization system provides for real time and efficient 'fly-through' navigation. The virtual camera can be arranged so that it moves along the airway in either direction. Snap shots were taken during fly-throughs. The system can automatically adjust the direction of the virtual camera and prevent collisions of the camera and the wall of the airway. A virtual laryngoscope (VL) system using OpenGL (Open Graphics Library) platform for interactive rendering and 3D visualization of the laryngeal framework and upper airway is established. OpenGL is supported on major operating systems and works with every major windowing system. The VL system runs on regular PC workstations and was successfully tested and evaluated using CT data from a normal subject.
Endocytoscopic findings of lymphomas of the stomach.
Isomoto, Hajime; Matsushima, Kayoko; Hayashi, Tomayoshi; Imaizumi, Yoshitaka; Shiota, Junya; Ishii, Hiroyuki; Minami, Hitomi; Ohnita, Ken; Takeshima, Fuminao; Shikuwa, Saburo; Miyazaki, Yasushi; Nakao, Kazuhiko
2013-12-26
The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy.
Fundamentals of endoscopic surgery: creation and validation of the hands-on test.
Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M
2014-03-01
The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high-stakes examinations, and, together with the knowledge component, may help contribute to the definition and determination of competence in endoscopy.
Esophageal varices on computed tomography and subsequent variceal hemorrhage.
Somsouk, Ma; To'o, Katherine; Ali, Mujtaba; Vittinghoff, Eric; Yeh, Benjamin M; Yee, Judy; Monto, Alex; Inadomi, John M; Aslam, Rizwan
2014-04-01
Endoscopy is recommended to screen for esophageal varices in patients with cirrhosis. The objective of this study was to identify features on abdominal CT imaging associated variceal hemorrhage (VH). A case-control study was performed among patients with cirrhosis who had a CT scan. Consecutive patients who experienced VH were included as cases, and patients without VH served as controls. Two radiologists recorded the maximal esophageal varix diameter in addition to other measures of portal hypertension at CT. The most powerful CT parameter associated with VH was the esophageal varix diameter (5.8 vs. 2.7 mm, p < 0.001; adjusted OR 1.84 per mm, p = 0.009). 63% of individuals with VH had a maximal varix diameter ≥5 mm compared to 7.5% of cirrhotic patients without VH (p < 0.001). In contrast, the proportion of individuals whose largest varix was <3 mm was 7.4% among VH cases compared to 54.7% among controls (p = 0.001). The varix diameter powerfully discriminated those with and without VH (C-statistic 0.84). A large esophageal varix diameter is strongly associated with subsequent VH. A threshold of <3 and ≥5 mm appears to identify patients with cirrhosis at low and high risk for hemorrhage.
Esophageal varices on computed tomography and subsequent variceal hemorrhage
Somsouk, Ma; To'o, Katherine; Ali, Mujtaba; Vittinghoff, Eric; Yeh, Benjamin M.; Yee, Judy; Monto, Alex; Inadomi, John M.; Aslam, Rizwan
2014-01-01
Purpose Endoscopy is recommended to screen for esophageal varices in patients with cirrhosis. The objective of this study was to identify features on abdominal CT imaging associated variceal hemorrhage (VH). Methods A case–control study was performed among patients with cirrhosis who had a CT scan. Consecutive patients who experienced VH were included as cases, and patients without VH served as controls. Two radiologists recorded the maximal esophageal varix diameter in addition to other measures of portal hypertension at CT. Results The most powerful CT parameter associated with VH was the esophageal varix diameter (5.8 vs. 2.7 mm, p < 0.001; adjusted OR 1.84 per mm, p = 0.009). 63% of individuals with VH had a maximal varix diameter ≥5 mm compared to 7.5% of cirrhotic patients without VH (p < 0.001). In contrast, the proportion of individuals whose largest varix was <3 mm was 7.4% among VH cases compared to 54.7% among controls (p = 0.001). The varix diameter powerfully discriminated those with and without VH (C-statistic 0.84). Conclusions A large esophageal varix diameter is strongly associated with subsequent VH. A threshold of <3 and ≥5 mm appears to identify patients with cirrhosis at low and high risk for hemorrhage. PMID:24366107
Duconseil, P; Turrini, O; Ewald, J; Soussan, J; Sarran, A; Gasmi, M; Moutardier, V; Delpero, J R
2015-06-01
To assess the accuracy of pre-operative staging in patients with peripheral pancreatic cystic neoplasms (pPCNs). From 2005 to 2011, 148 patients underwent a pancreatectomy for pPCNs. The pre-operative examination methods of computed tomography (CT), magnetic resonance imaging (MRI), endoscopic ultrasonography (EUS) were compared for their ability to predict the suggested diagnosis accurately, and the definitive diagnosis was affirmed by pathological examination. A mural nodule was detected in 34 patients (23%): only 1 patient (3%) had an invasive pPCN at the final histological examination. A biopsy was performed in 79 patients (53%) during EUS: in 55 patients (70%), the biopsy could not conclude a diagnosis; the biopsy provided the correct and wrong diagnosis in 19 patients (24%) and 5 patients (6%), respectively. A correct diagnosis was affirmed by CT, EUS and pancreatic MRI in 60 (41%), 103 (74%) and 80 (86%) patients (when comparing EUS and MRI; P = 0.03), respectively. The positive predictive values (PPVs) of CT, EUS and MRI were 70%, 75% and 87%, respectively. Pancreatic MRI appears to be the most appropriate examination to diagnose pPCNs accurately. EUS alone had a poor PPV. Mural nodules in a PCN should not be considered an indisputable sign of pPCN invasiveness. © 2015 International Hepato-Pancreato-Biliary Association.
Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B
2006-11-01
To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.
ERIC Educational Resources Information Center
Chen, Jian; Smith, Andrew D.; Khan, Majid A.; Sinning, Allan R.; Conway, Marianne L.; Cui, Dongmei
2017-01-01
Recent improvements in three-dimensional (3D) virtual modeling software allows anatomists to generate high-resolution, visually appealing, colored, anatomical 3D models from computed tomography (CT) images. In this study, high-resolution CT images of a cadaver were used to develop clinically relevant anatomic models including facial skull, nasal…
Dual modality virtual colonoscopy workstation: design, implementation, and preliminary evaluation
NASA Astrophysics Data System (ADS)
Chen, Dongqing; Meissner, Michael
2006-03-01
The aim of this study is to develop a virtual colonoscopy (VC) workstation that supports both CT (computed tomography) and MR (magnetic resonance) imaging procedures. The workflow should be optimized and be able to take advantage of both image modalities. The technological break through is at the real-time volume rendering of spatial-intensity-inhomogeneous MR images to achieve high quality 3D endoluminal view. VC aims at visualizing CT or MR tomography images for detection of colonic polyp and lesion. It is also called as CT/MR colonography based on the imaging modality that is employed. The published results of large scale clinical trial demonstrated more than 90% of sensitivity on polyp detection for certain CT colonography (CTC) workstation. A drawback of the CT colonoscopy is the radiation exposure. MR colonography (MRC) is free from the X-ray radiation. It achieved almost 100% specificity for polyp detection in published trials. The better tissue contrast in MR image allows the accurate diagnosis of inflammatory bowel disease also, which is usually difficult in CTC. At present, most of the VC workstations are designed for CT examination. They are not able to display multi-sequence MR series concurrently in a single application. The automatic correlation between 2D and 3D view is not available due to the difficulty of 3D model building for MR images. This study aims at enhancing a commercial VC product that was successfully used for CTC to equally support dark-lumen protocol MR procedure also.
Dual energy computed tomography for the head.
Naruto, Norihito; Itoh, Toshihide; Noguchi, Kyo
2018-02-01
Dual energy CT (DECT) is a promising technology that provides better diagnostic accuracy in several brain diseases. DECT can generate various types of CT images from a single acquisition data set at high kV and low kV based on material decomposition algorithms. The two-material decomposition algorithm can separate bone/calcification from iodine accurately. The three-material decomposition algorithm can generate a virtual non-contrast image, which helps to identify conditions such as brain hemorrhage. A virtual monochromatic image has the potential to eliminate metal artifacts by reducing beam-hardening effects. DECT also enables exploration of advanced imaging to make diagnosis easier. One such novel application of DECT is the X-Map, which helps to visualize ischemic stroke in the brain without using iodine contrast medium.
Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut
2018-06-07
To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.
Seemann, M D; Gebicke, K; Luboldt, W; Albes, J M; Vollmar, J; Schäfer, J F; Beinert, T; Englmeier, K H; Bitzer, M; Claussen, C D
2001-07-01
The aim of this study was to demonstrate the possibilities of a hybrid rendering method, the combination of a color-coded surface and volume rendering method, with the feasibility of performing surface-based virtual endoscopy with different representation models in the operative and interventional therapy control of the chest. In 6 consecutive patients with partial lung resection (n = 2) and lung transplantation (n = 4) a thin-section spiral computed tomography of the chest was performed. The tracheobronchial system and the introduced metallic stents were visualized using a color-coded surface rendering method. The remaining thoracic structures were visualized using a volume rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle surface model, a shaded-surface model and a transparent shaded-surface model. The hybrid 3D visualization uses the advantages of both the color-coded surface and volume rendering methods and facilitates a clear representation of the tracheobronchial system and the complex topographical relationship of morphological and pathological changes without loss of diagnostic information. Performing virtual bronchoscopy with the transparent shaded-surface model facilitates a reasonable to optimal, simultaneous visualization and assessment of the surface structure of the tracheobronchial system and the surrounding mediastinal structures and lesions. Hybrid rendering relieve the morphological assessment of anatomical and pathological changes without the need for time-consuming detailed analysis and presentation of source images. Performing virtual bronchoscopy with a transparent shaded-surface model offers a promising alternative to flexible fiberoptic bronchoscopy.
Das, Roby; Sureshkumar, Sathasivam; Sreenath, Gubbi S; Kate, Vikram
2016-01-01
Comparison of Helicobacter pylori eradication rates, side effects, compliance, cost, and ulcer recurrence of sequential therapy (ST) with that of concomitant therapy (CT) in patients with perforated duodenal ulcer following simple omental patch closure. Sixty-eight patients with perforated duodenal ulcer treated with simple closure and found to be H. pylori positive on three months follow-up were randomized to receive either ST or CT for H. pylori eradication. Urease test and Giemsa stain were used to assess for H. pylori eradication status. Follow-up endoscopies were done after 3 months, 6 months, and 1 year to evaluate the ulcer recurrence. H. pylori eradication rates were similar in ST and CT groups on intention-to-treat (ITT) analysis (71.43% vs 81.80%,P = 0.40). Similar eradication rates were also found in per-protocol (PP) analysis (86.20% vs 90%,P = 0.71). Ulcer recurrence rate in ST groups and CT groups at 3 months (17.14% vs 6.06%,P = 0.26), 6 months (22.86% vs 9.09%,P = 0.19), and at 1 year (25.71% vs 15.15%,P = 0.37) of follow-up was also similar by ITT analysis. Compliance and side effects to therapies were comparable between the groups. The most common side effects were diarrhoea and metallic taste in ST and CT groups, respectively. A complete course of ST costs Indian Rupees (INR) 570.00, whereas CT costs INR 1080.00. H. pylori eradication rates, side effects, compliance, cost, and ulcer recurrences were similar between the two groups. The ST was more economical compared with CT.
Ma, Yan; Shao, Xiaonan
2017-12-01
Uterine fibroids are the most common pelvic solid tumors and common to 25% of women. F-fluorodexyglucose (F-FDG) is an energy metabolism tracer. Although FDG is generally concentrated in malignant lesions with high glucose metabolism, it can also accumulate in normal tissues, benign lesions, and inflammatory sites. The exact mechanism of FDG uptake by uterine fibroids is not clear. Here, we report a case of uterine fibroids with positive F-FDG positron emission tomography/computed tomography (PET/CT) imaging and significantly increased CA19-9. The patient was a 43-year-old woman and admitted to our hospital because of "1-year-extended menstrual periods." At admission, she had normal CA125, AFP, and CEA level and CA19-9>1000.00 U/mL. Gynecological transvaginal ultrasound found enlarged uterus with an anterior hypoechoic area of 3.9 × 4.2 cm. CT and contrast-enhanced CT showed significantly enhanced mass shadow on the left anterior wall of uterus. F-FDG PET/CT showed increased FDG metabolism of tumor in the anterior wall of the uterus. Laparoscopic hysterectomy was performed. Pathological examination demonstrated subserosal leiomyoma. Her CA19-9 level dropped to 91.50 U/mL 1 day after surgery. Significantly elevated CA19-9 was positioned in the uterus by PET/CT imaging, which not only avoided unnecessary gastrointestinal endoscopy and reduced the suffering of patients, but also strengthened the operation confidence in gynecologists. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
A Virtual Learning Environment for Part-Time MASW Students: An Evaluation of the WebCT
ERIC Educational Resources Information Center
Chan, Charles C.; Tsui, Ming-sum; Chan, Mandy Y. C.; Hong, Joe H.
2008-01-01
This study aims to evaluate the perception of a cohort of social workers studying for a part-time master's program in social work in using the popular Web-based learning platform--World Wide Web Course Tools (WebCT) as a complimentary method of teaching and learning. It was noted that social work profession began incorporating computer technology…
Splitting a colon geometry with multiplanar clipping
NASA Astrophysics Data System (ADS)
Ahn, David K.; Vining, David J.; Ge, Yaorong; Stelts, David R.
1998-06-01
Virtual colonoscopy, a recent three-dimensional (3D) visualization technique, has provided radiologists with a unique diagnostic tool. Using this technique, a radiologist can examine the internal morphology of a patient's colon by navigating through a surface-rendered model that is constructed from helical computed tomography image data. Virtual colonoscopy can be used to detect early forms of colon cancer in a way that is less invasive and expensive compared to conventional endoscopy. However, the common approach of 'flying' through the colon lumen to visually search for polyps is tedious and time-consuming, especially when a radiologist loses his or her orientation within the colon. Furthermore, a radiologist's field of view is often limited by the 3D camera position located inside the colon lumen. We have developed a new technique, called multi-planar geometry clipping, that addresses these problems. Our algorithm divides a complex colon anatomy into several smaller segments, and then splits each of these segments in half for display on a static medium. Multi-planar geometry clipping eliminates virtual colonoscopy's dependence upon expensive, real-time graphics workstations by enabling radiologists to globally inspect the entire internal surface of the colon from a single viewpoint.
Thong, Patricia S P; Tandjung, Stephanus S; Movania, Muhammad Mobeen; Chiew, Wei-Ming; Olivo, Malini; Bhuvaneswari, Ramaswamy; Seah, Hock-Soon; Lin, Feng; Qian, Kemao; Soo, Khee-Chee
2012-05-01
Oral lesions are conventionally diagnosed using white light endoscopy and histopathology. This can pose a challenge because the lesions may be difficult to visualise under white light illumination. Confocal laser endomicroscopy can be used for confocal fluorescence imaging of surface and subsurface cellular and tissue structures. To move toward real-time "virtual" biopsy of oral lesions, we interfaced an embedded computing system to a confocal laser endomicroscope to achieve a prototype three-dimensional (3-D) fluorescence imaging system. A field-programmable gated array computing platform was programmed to enable synchronization of cross-sectional image grabbing and Z-depth scanning, automate the acquisition of confocal image stacks and perform volume rendering. Fluorescence imaging of the human and murine oral cavities was carried out using the fluorescent dyes fluorescein sodium and hypericin. Volume rendering of cellular and tissue structures from the oral cavity demonstrate the potential of the system for 3-D fluorescence visualization of the oral cavity in real-time. We aim toward achieving a real-time virtual biopsy technique that can complement current diagnostic techniques and aid in targeted biopsy for better clinical outcomes.
Integration of stereotactic ultrasonic data into an interactive image-guided neurosurgical system
NASA Astrophysics Data System (ADS)
Shima, Daniel W.; Galloway, Robert L., Jr.
1998-06-01
Stereotactic ultrasound can be incorporated into an interactive, image-guide neurosurgical system by using an optical position sensor to define the location of an intraoperative scanner in physical space. A C-program has been developed that communicates with the OptotrakTM system developed by Northern Digital Inc. to optically track the three-dimensional position and orientation of a fan-shaped area defined with respect to a hand-held probe. (i.e., a virtual B-mode ultrasound fan beam) Volumes of CT and MR head scans from the same patient are registered to a location in physical space using a point-based technique. The coordinates of the virtual fan beam in physical space are continuously calculated and updated on-the-fly. During each program loop, the CT and MR data volumes are reformatted along the same plane and displayed as two fan-shaped images that correspond to the current physical-space location of the virtual fan beam. When the reformatted preoperative tomographic images are eventually paired with a real-time intraoperative ultrasound image, a neurosurgeon will be able to use the unique information of each imaging modality (e.g., the high resolution and tissue contrast of CT and MR and the real-time functionality of ultrasound) in a complementary manner to identify structures in the brain more easily and to guide surgical procedures more effectively.
Stadelmann, Vincent A; Zderic, Ivan; Baur, Annick; Unholz, Cynthia; Eberli, Ursula; Gueorguiev, Boyko
2016-02-01
Vertebroplasty has been shown to reinforce weak vertebral bodies and reduce fracture risks, yet cement leakage is a major problem that can cause severe complications. Since cement flow is nearly impossible to control during surgery, small volumes of cement are injected, but then mechanical benefits might be limited. A better understanding of cement flows within bone structure is required to further optimize vertebroplasty and bone augmentation in general. We developed a novel imaging method, composite time-lapse CT, to characterize cement flow during injection. In brief, composite-resolution time-lapse CT exploits the qualities of microCT and clinical CT. The method consists in overlaying low-resolution time-lapse CT scans acquired during injection onto pre-operative high-resolution microCT scans, generating composite-resolution time-lapse CT series of cement flow within bone. In this in vitro study, composite-resolution time-lapse CT was applied to eight intact and five artificially fractured cadaveric vertebrae during vertebroplasty. The time-lapse scans were acquired at one-milliliter cement injection steps until a total of 10 ml cement was injected. The composite-resolution series were then converted into micro finite element models to compute strains distribution under virtual axial loading. Relocation of strain energy density within bone structure was observed throughout the progression of the procedure. Interestingly, the normalized effect of cement injection on the overall stiffness of the vertebrae was similar between intact and fractured specimens, although at different orders of magnitude. In conclusion, composite time-lapse CT can picture cement flows during bone augmentation. The composite images can also be easily converted into finite element models to compute virtual strain distributions under loading at every step of an injection, providing deeper understanding on the biomechanics of vertebroplasty. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
MicroPET/CT Colonoscopy in long-lived Min mouse using NM404
NASA Astrophysics Data System (ADS)
Christensen, Matthew B.; Halberg, Richard B.; Schutten, Melissa M.; Weichert, Jamey P.
2009-02-01
Colon cancer is a leading cause of death in the US, even though many cases are preventable if tumors are detected early. One technique to promote screening is Computed Tomography Colonography (CTC). NM404 is a second generation phospholipid ether analogue which has demonstrated selective uptake and prolonged retention in 43/43 types of malignant tumors but not inflammatory sites or premalignant lesions. The purpose of this experiment was to evaluate (SWR x B6 )F1.Min mice as a preclinical model to test MicroPET/CT dual modality virtual colonoscopy. Each animal was given an IV injection of 124I-NM404 (100 uCi) 24, 48 and 96 hours prior to scanning on a dedicated microPET/CT system. Forty million counts were histogrammed in 3D and reconstructed using an OSEM 2D algorithm. Immediately after PET acquisition, a 93 m volumetric CT was acquired at 80 kVp, 800 uA and 350 ms exposures. Following CT, the mouse was sacrificed. The entire intestinal tract was excised, washed, insufflated, and scanned ex vivo A total of eight tissue samples from the small intestine were harvested: 5 were benign adenomas, 2 were malignant adenocarcinomas, and 1 was a Peyer's patch (lymph tissue) . The sites of these samples were positioned on CT and PET images based on morphological cues and the distance from the anus. Only 1/8 samples showed tracer uptake. several hot spots in the microPET image were not chosen for histology. (SWR x B6)F1.Min mice develop benign and malignant tumors, making this animal model a strong candidate for future dual modality microPET/CT virtual colonography studies.
Interactive CT-Video Registration for the Continuous Guidance of Bronchoscopy
Merritt, Scott A.; Khare, Rahul; Bascom, Rebecca
2014-01-01
Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient’s 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As a result, image-guided bronchoscopy systems, drawing upon the concept of CT-based virtual bronchoscopy (VB), have been proposed. These systems attempt to register the bronchoscope’s live position within the chest to a CT-based virtual chest space. Recent methods, which register the bronchoscopic video to CT-based endoluminal airway renderings, show promise but do not enable continuous real-time guidance. We present a CT-video registration method inspired by computer-vision innovations in the fields of image alignment and image-based rendering. In particular, motivated by the Lucas–Kanade algorithm, we propose an inverse-compositional framework built around a gradient-based optimization procedure. We next propose an implementation of the framework suitable for image-guided bronchoscopy. Laboratory tests, involving both single frames and continuous video sequences, demonstrate the robustness and accuracy of the method. Benchmark timing tests indicate that the method can run continuously at 300 frames/s, well beyond the real-time bronchoscopic video rate of 30 frames/s. This compares extremely favorably to the ≥1 s/frame speeds of other methods and indicates the method’s potential for real-time continuous registration. A human phantom study confirms the method’s efficacy for real-time guidance in a controlled setting, and, hence, points the way toward the first interactive CT-video registration approach for image-guided bronchoscopy. Along this line, we demonstrate the method’s efficacy in a complete guidance system by presenting a clinical study involving lung cancer patients. PMID:23508260
Jiřík, Miroslav; Bartoš, Martin; Tomášek, Petr; Malečková, Anna; Kural, Tomáš; Horáková, Jana; Lukáš, David; Suchý, Tomáš; Kochová, Petra; Hubálek Kalbáčová, Marie; Králíčková, Milena; Tonar, Zbyněk
2018-06-01
Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans. © 2018 Wiley Periodicals, Inc.
Kubo, Naoki; Furusawa, Norihiko; Imai, Shinichiro; Terada, Masaru
2018-06-27
Horseshoe kidney is a congenital malformation in which the bilateral kidneys are fused. It is frequently complicated by other congenital malformations and is often accompanied by anomalies of the ureteropelvic and vascular systems, which must be evaluated to avoid iatrogenic injury. We report a case of laparoscopic high anterior resection of rectosigmoid colon cancer associated with a horseshoe kidney using preoperative 3D-CT angiography. A 52-year-old Japanese man with lower abdominal pain underwent lower endoscopy, revealing a type 2 lesion in the rectosigmoid colon. He was diagnosed with rectosigmoid colon cancer with multiple lung metastases and a horseshoe kidney on computed tomography (CT) scan. Three-dimensional (3D)-CT angiography showed an aberrant renal artery at the isthmus from 3 cm under the inferior mesenteric artery (IMA) branch of the aorta. Laparoscopic anterior rectal resection was performed. During the operation, the inferior mesenteric artery, left ureter, left gonadal vessels, and hypogastric nerve plexus could be seen passing over the horseshoe kidney isthmus and were preserved. The left branch of aberrant renal artery that was close to IMA was also detected and preserved. To prevent intraoperative misidentification, 3D-CT angiography should be performed preoperatively to ascertain the precise positional relationships between the extra renal arteries and the kidney. We always must consider anomalous locations of renal vessels, ureter, gonadal vessels, and lumbar splanchnic nerve to avoid laparoscopic iatrogenic injury in patients with a horseshoe kidney.
Mattar, Rejane; Basile-Filho, Anibal; Kemp, Rafael; Santos, José Sebastião dos
2013-01-01
To analyze the usefulness of Quick Lactose Intolerance Test in relation to the genetic test based on LCT-13910C>T genotypes, previously validated for clinical practice, for primary hypolactasia/lactase-persistence diagnosis. Thirty-two dyspeptic patients that underwent upper gastrointestinal endoscopy entered the study. Two postbulbar duodenal biopsies were taken for the Quick test, and gastric antral biopsy for DNA extraction and LCT-13910C>T polymorphism analysis. DNA was also extracted from biopsies after being used in the Quick Test that was kept frozen until extraction. Nine patients with lactase-persistence genotype (LCT-13910CT or LCT-13910TT) had normolactasia, eleven patients with hypolactasia genotype (LCT-13910CC) had severe hypolactasia, and among twelve with mild hypolactasia, except for one that had LCT-13910CT genotype, all the others had hypolactasia genotype. The agreement between genetic test and quick test was high (p<0.0001; Kappa Index 0.92). Most of the patients that reported symptoms with lactose-containing food ingestion had severe hypolactasia (p<0.05). Amplification with good quality PCR product was also obtained with DNA extracted from biopsies previously used in the Quick Test; thus, for the future studies antral gastric biopsies for genetic test would be unnecessary. Quick test is highly sensitive and specific for hypolactasia diagnosis and indicated those patients with symptoms of lactose intolerance.
Haq, Jahrad; Patel, Nishma; Weimer, Katherine; Matthews, N Shaun
2014-04-01
Ankylosis of the temporomandibular joint (TMJ) is a debilitating condition that can result in pain, trismus, and a poor quality of life. It can be caused by injury, infection, and rheumatoid disease. Current management includes gap arthroplasty, interpositional arthroplasty, and reconstruction. Traditionally, joints are reconstructed using stock implants, or the procedure is done in two stages with an additional computed tomography (CT) scan between the resective and reconstructive procedures and use of stereolithographic models to aid the design of the definitive prostheses. We describe a technique for the resection of ankylosis and reconstruction of the joint in a single operation using virtually designed custom-made implants. Five patients with ankylosis of the TMJ had a single stage operation with reconstruction between 2010 and 2012. All had preoperative high-resolution CT with contrast angiography. During an international web-based teleconference between the surgeon and the engineer a virtual resection of the ankylosis was done using the reconstructed CT images. The bespoke cutting guides and implants were designed virtually at the same time and were then manufactured precisely using computer-aided design and manufacture (CAD-CAM) over 6 weeks. After release of the ankylosis and reconstruction, the patients underwent an exercise regimen to improve mouth opening. Follow-up was for a minimum of 6 months. Four patients had one operation, and one patient had two. Median/Mean maximum incisal opening increased from 0.6mm before operation to 25 mm afterwards (range 23-27), and there was minimal surgical morbidity. This new method effectively treats ankylosis of the TMJ in a single stage procedure. Fewer operations and hospital stays, and the maintenance of overall clinical outcome are obvious advantages. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
A virtual simulator designed for collision prevention in proton therapy.
Jung, Hyunuk; Kum, Oyeon; Han, Youngyih; Park, Hee Chul; Kim, Jin Sung; Choi, Doo Ho
2015-10-01
In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer's machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient's body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine's components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.
Radiofrequency ablation for hepatocellular carcinoma: assistant techniques for difficult cases.
Inoue, Tatsuo; Minami, Yasunori; Chung, Hobyung; Hayaishi, Sousuke; Ueda, Taisuke; Tatsumi, Chie; Takita, Masahiro; Kitai, Satoshi; Hatanaka, Kinuyo; Ishikawa, Emi; Yada, Norihisa; Hagiwara, Satoru; Ueshima, Kazuomi; Kudo, Masatoshi
2010-07-01
To confirm the safety and effectiveness of techniques to assist radiofrequency ablation (RFA) for difficult cases, we retrospectively evaluated successful treatment rates, early complications and local tumor progressions. Between June 1999 and April 2009, a total of 341 patients with 535 nodules were treated as difficult cases. Artificial pleural effusion assisted ablation was performed on 64 patients with 82 nodules. Artificial ascites-assisted ablation was performed on 11 patients with 13 nodules. Cooling by endoscopic nasobiliary drainage (ENBD) tube-assisted ablation was performed on 6 patients with 8 nodules. When the tumors were not well visualized with conventional B-mode ultrasonography (US), contrast-enhanced US-assisted ablation with Levovist or Sonazoid or virtual CT sonography-assisted ablation was performed. Contrast-enhanced US-assisted ablation was performed on 139 patients with 224 nodules and virtual CT sonography-assisted ablation was performed on 121 patients with 209 nodules. In total, complete ablation was achieved in 514 of 535 (96%) nodules in difficult cases. For RFA with artificial pleural effusion, artificial ascites and ENBD, complete response was confirmed in all cases. For contrast-enhanced US- and CT sonography-assisted ablation, complete response was 95%. Early complications were recognized in 24 cases (4.5%). All cases recovered with no invasive treatment. Local tumor recurrence was investigated in 377 nodules of 245 patients, and 69 (18%) nodules were positive. Tumor recurrences in each assisted technique were 14.7% in artificial pleural effusion cases, 7% in artificial ascites, 12.5% in ENBD tube cases, 31% in virtual CT sonography, and 8.5% in contrast-enhanced US. Although local tumor progression needs to be carefully monitored, assisted techniques of RFA for difficult cases are well tolerated and expand the indications of RFA. Copyright (c) 2010 S. Karger AG, Basel.
Automatic thoracic body region localization
NASA Astrophysics Data System (ADS)
Bai, PeiRui; Udupa, Jayaram K.; Tong, YuBing; Xie, ShiPeng; Torigian, Drew A.
2017-03-01
Radiological imaging and image interpretation for clinical decision making are mostly specific to each body region such as head & neck, thorax, abdomen, pelvis, and extremities. For automating image analysis and consistency of results, standardizing definitions of body regions and the various anatomic objects, tissue regions, and zones in them becomes essential. Assuming that a standardized definition of body regions is available, a fundamental early step needed in automated image and object analytics is to automatically trim the given image stack into image volumes exactly satisfying the body region definition. This paper presents a solution to this problem based on the concept of virtual landmarks and evaluates it on whole-body positron emission tomography/computed tomography (PET/CT) scans. The method first selects a (set of) reference object(s), segments it (them) roughly, and identifies virtual landmarks for the object(s). The geometric relationship between these landmarks and the boundary locations of body regions in the craniocaudal direction is then learned through a neural network regressor, and the locations are predicted. Based on low-dose unenhanced CT images of 180 near whole-body PET/CT scans (which includes 34 whole-body PET/CT scans), the mean localization error for the boundaries of superior of thorax (TS) and inferior of thorax (TI), expressed as number of slices (slice spacing ≍ 4mm)), and using either the skeleton or the pleural spaces as reference objects, is found to be 3,2 (using skeleton) and 3, 5 (using pleural spaces) respectively, or in mm 13, 10 mm (using skeleton) and 10.5, 20 mm (using pleural spaces), respectively. Improvements of this performance via optimal selection of objects and virtual landmarks and other object analytics applications are currently being pursued. and the skeleton and pleural spaces used as a reference objects
Mangold, Stefanie; Gatidis, Sergios; Luz, Oliver; König, Benjamin; Schabel, Christoph; Bongers, Malte N; Flohr, Thomas G; Claussen, Claus D; Thomas, Christoph
2014-12-01
The objective of this study was to retrospectively determine the potential of virtual monoenergetic (ME) reconstructions for a reduction of metal artifacts using a new-generation single-source computed tomographic (CT) scanner. The ethics committee of our institution approved this retrospective study with a waiver of the need for informed consent. A total of 50 consecutive patients (29 men and 21 women; mean [SD] age, 51.3 [16.7] years) with metal implants after osteosynthetic fracture treatment who had been examined using a single-source CT scanner (SOMATOM Definition Edge; Siemens Healthcare, Forchheim, Germany; consecutive dual-energy mode with 140 kV/80 kV) were selected. Using commercially available postprocessing software (syngo Dual Energy; Siemens AG), virtual ME data sets with extrapolated energy of 130 keV were generated (medium smooth convolution kernel D30) and compared with standard polyenergetic images reconstructed with a B30 (medium smooth) and a B70 (sharp) kernel. For quantification of the beam hardening artifacts, CT values were measured on circular lines surrounding bone and the osteosynthetic device, and frequency analyses of these values were performed using discrete Fourier transform. A high proportion of low frequencies to the spectrum indicates a high level of metal artifacts. The measurements in all data sets were compared using the Wilcoxon signed rank test. The virtual ME images with extrapolated energy of 130 keV showed significantly lower contribution of low frequencies after the Fourier transform compared with any polyenergetic data set reconstructed with D30, B70, and B30 kernels (P < 0.001). Sequential single-source dual-energy CT allows an efficient reduction of metal artifacts using high-energy ME extrapolation after osteosynthetic fracture treatment.
Wakabayashi, Mutsumi; Sekiguchi, Yasunobu; Shimada, Asami; Ichikawa, Kunimoto; Sugimoto, Keiji; Tomita, Shigeki; Izumi, Hiroshi; Nakamura, Noriko; Sawada, Tomohiro; Ohta, Yasunori; Komatsu, Norio; Noguchi, Masaaki
2014-01-01
A 60-year-old man complained of nausea, vomiting, decreased appetite, and a feeling of abdominal fullness in August 2013. Based on biopsy findings from an upper gastrointestinal endoscopy examination, a diagnosis of non-Hodgkin's lymphoma (NHL), diffuse large B-cell lymphoma (DLBCL), non-GC type, was made. F18-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) revealed abnormal accumulations solely in the gastric wall (SUVmax = 14.5), the left adrenal gland (SUVmax = 14.3), and the right adrenal gland (SUVmax = 8.5). The clinical stage (Ann Arbor) was IVA, the serum LDH level was within the reference range, and the International Prognostic Index (IPI) was low-intermediate. The serum soluble IL-2 receptor level was within the reference range, and there was no evidence of HIV, EB virus, or autoimmune disease. After the completion of 4 cycles of R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone) and 2 parallel cycles of prophylactic intrathecal (I.T.), an upper gastrointestinal endoscopy and a FDG-PET/CT examination showed complete remission (CR). The patient received 8 cycles of ritsuximab therapy, 6 cycles of CHOP, and 3 cycles of I.T. The patient has maintained a CR for about 14 months. A literature search revealed that malignant lymphoma with involvement confined to the adrenal gland and gastrointestinal tract is exceedingly rare, and only 3 cases of malignant lymphoma have been reported, with involvement of the stomach in 2 cases and the duodenum in 1 case. All of the cases were diagnosed as DLBCL. The case described herein represents the third case with involvement of the stomach.
Hassan, I; Bin Dayne, K; Kappus, C; Gerdes, B; Rothmund, M; Hellwig, D
2007-04-01
The increasing use of minimally invasive surgery, which has a longer learning curve compared to open surgery lets the necessity to develop training programs to improve endoscopic skills of trainees become ever clearer. The aim of this study was to compare the endoscopic skills of neurosurgeons versus general surgeons at first exposure to a virtual reality simulator. 72 general surgeons who visited the 122nd Conference of the German Surgeons Society (DGCH in Munich 2005) and 35 neuroendoscopic surgeons, who visited the Third World Conference of the International Study Group of Neuroendoscopy (ISGNE in Marburg 2005) participated in this study. Each participant performed the basic module "clip application" on the virtual reality simulator (LapSim). All participants were given the same pretest instructions. Time to complete the task, error score and economy of motion were recorded. The general surgeons performed the clip application faster, but with more errors than neuroendoscopic surgeons. However, the difference of both parameters was not significant. Both surgeon groups have a similar score for economy of motion. Although neuroendoscopic surgeons were exposed to a foreign procedure and unfamiliar equipment, they were able to perform virtual endoscopy with similar accuracy as general surgeons, who are adapted to these endoscopic instruments and procedures and do these daily.
High-level virtual reality simulator for endourologic procedures of lower urinary tract.
Reich, Oliver; Noll, Margarita; Gratzke, Christian; Bachmann, Alexander; Waidelich, Raphaela; Seitz, Michael; Schlenker, Boris; Baumgartner, Reinhold; Hofstetter, Alfons; Stief, Christian G
2006-06-01
To analyze the limitations of existing simulators for urologic techniques, and then test and evaluate a novel virtual reality (VR) simulator for endourologic procedures of the lower urinary tract. Surgical simulation using VR has the potential to have a tremendous impact on surgical training, testing, and certification. Endourologic procedures seem to be an ideal target for VR systems. The URO-Trainer features genuine VR, obtained from digital video footage of more than 400 endourologic diagnostic and therapeutic procedures, as well as data from cross-sectional imaging. The software offers infinite random variations of the anatomy and pathologic features for diagnosis and surgical intervention. An advanced haptic force feedback is incorporated. Virtual cystoscopy and resection of bladder tumors were evaluated by 24 medical students and 12 residents at our department. The system was assessed by more than 150 international urologists with varying experience at different conventions and workshops from March 2003 to September 2004. Because of these evaluations and constant evolutions, the final version provides a genuine representation of endourologic procedures. Objective data are generated by a tutoring system that has documented evident teaching benefits for medical students and residents in cystoscopy and treatment of bladder tumors. The URO-Trainer represents the latest generation of endoscopy simulators. Authentic visual and haptic sensations, unlimited virtual cases, and an intelligent tutoring system make this modular system an important improvement in computer-based training and quality control in urology.
Acute severe neck pain and dysphagia following cervical maneuver: diagnostic approach.
Trendel, D; Bonfort, G; Lapierre-Combes, M; Salf, E; Barberot, J-P
2014-04-01
Overlooking an etiologic hypothesis in acute neck pain with dysphagia may lead to misdiagnosis. A 51-year-old man who had received cervical manipulation came to the emergency unit with evolutive acute neck pain, cervical spine stiffness and odynophagia, without fever or other signs of identified pathology. Cervical X-ray and CT angiography of the supra-aortic vessels ruled out traumatic etiology (fracture or arterial dissection) and revealed an accessory bone, orienting diagnosis toward retropharyngeal abscess, which was, however, belied by endoscopy performed under general anesthesia. A second CT scan with contrast injection and tissue phase ruled out infection, revealing a retropharyngeal calcification inducing retropharyngeal edema. Evolution under analgesics was favorable within 13 days. Given a clinical triad associating acute neck pain, cervical spine stiffness and odynophagia, traumatic or infectious etiology was initially suspected. Cervical CT diagnosed calcific tendinitis of the longus colli, revealing a pathognomic retropharyngeal calcification. Secondary to hydroxyapatite deposits anterior to the odontoid process of the axis, this is a rare form of tendinopathy, usually showing favorable evolution in 10-15 days under analgesic and anti-inflammatory treatment. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Pneumoperitoneum after virtual colonoscopy: causes, risk factors, and management.
Baccaro, Leopoldo M; Markelov, Alexey; Wilhelm, Jakub; Bloch, Robert
2014-06-01
Computed tomographic virtual colonoscopy (CTVC) is a safe and minimally invasive modality when compared with fiberoptic colonoscopy for evaluating the colon and rectum. We have reviewed the risks for colonic perforation by investigating the relevant literature. The objectives of this study were to assess the risk of colonic perforation during CTVC, describe risk factors, evaluate ways to reduce the incidence complications, and to review management and treatment options. A formal search of indexed publications was performed through PubMed. Search queries using keywords "CT colonography," "CT virtual colonoscopy," "virtual colonoscopy," and "perforation" yielded a total of 133 articles. A total of eight case reports and four review articles were selected. Combining case reports and review articles, a total of 25 cases of colonic perforation after CTVC have been reported. Causes include, but are not limited to, diverticular disease, irritable bowel diseases, obstructive processes, malignancies, and iatrogenic injury. Both operative and nonoperative management has been described. Nonoperative management has been proven safe and successful in minimally symptomatic and stable patients. Colonic perforation after CTVC is a rare complication and very few cases have been reported. Several risk factors are recurrent in the literature and must be acknowledged at the time of the study. Management options vary and should be tailored to each individual patient.
SU-F-303-12: Implementation of MR-Only Simulation for Brain Cancer: A Virtual Clinical Trial
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glide-Hurst, C; Zheng, W; Kim, J
2015-06-15
Purpose: To perform a retrospective virtual clinical trial using an MR-only workflow for a variety of brain cancer cases by incorporating novel imaging sequences, tissue segmentation using phase images, and an innovative synthetic CT (synCT) solution. Methods: Ten patients (16 lesions) were evaluated using a 1.0T MR-SIM including UTE-DIXON imaging (TE = 0.144/3.4/6.9ms). Bone-enhanced images were generated from DIXON-water/fat and inverted UTE. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating intersection and Dice similarity coefficients (DSC) using CT-SIM as ground truth. SynCTs were generated using voxel-based weighted summation incorporating T2, FLAIR, UTE1,more » and bone-enhanced images. Mean absolute error (MAE) characterized HU differences between synCT and CT-SIM. Dose was recalculated on synCTs; differences were quantified using planar gamma analysis (2%/2 mm dose difference/distance to agreement) at isocenter. Digitally reconstructed radiographs (DRRs) were compared. Results: On average, air maps intersected 80.8 ±5.5% (range: 71.8–88.8%) between MR-SIM and CT-SIM yielding DSCs of 0.78 ± 0.04 (range: 0.70–0.83). Whole-brain MAE between synCT and CT-SIM was 160.7±8.8 HU, with the largest uncertainty arising from bone (MAE = 423.3±33.2 HU). Gamma analysis revealed pass rates of 99.4 ± 0.04% between synCT and CT-SIM for the cohort. Dose volume histogram analysis revealed that synCT tended to yield slightly higher doses. Organs at risk such as the chiasm and optic nerves were most sensitive due to their proximities to air/bone interfaces. DRRs generated via synCT and CT-SIM were within clinical tolerances. Conclusion: Our approach for MR-only simulation for brain cancer treatment planning yielded clinically acceptable results relative to the CT-based benchmark. While slight dose differences were observed, reoptimization of treatment plans and improved image registration can address this limitation. Future work will incorporate automated registration between setup images (cone-beam CT and kilovoltage images) for synCT and CT-SIM. Submitting institution holds research agreements with Philips HealthCare, Best, Netherlands and Varian Medical Systems, Palo Alto, CA. Research partially sponsored via an Internal Mentored Research Grant.« less
Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Jin Hyoung; Shin, Ji Hoon; Ko, Heung Kyu; Song, Ho-Young
2013-07-01
To evaluate technical safety, clinical safety, and effectiveness of vascular plug-assisted retrograde transvenous obliteration (RTO) for treatment of gastric varices (GV) and hepatic encephalopathy (HE). This retrospective study was approved by the institutional review board; written informed consent was waived. From April 2009 to December 2011, 20 patients (13, GV; seven, HE) who had undergone vascular plug-assisted RTO were retrospectively evaluated. After retrograde transvenous placement of a vascular plug in the left adrenal vein or gastrorenal shunt, subsequent gelatin-sponge embolization of both gastrorenal shunt and GV was performed. Follow-up computed tomography (CT) and upper gastrointestinal tract endoscopy were performed; clinical and laboratory data were collected to evaluate primary (technical success, complications, clinical success) and secondary (change of liver function by using the Child-Pugh score, worsening of esophageal varices) end points. Laboratory data before and after vascular plug-assisted RTO were compared (paired-sample t test). Placement of the vascular plug and subsequent gelatin-sponge embolization were technically successful in all 20 patients, with no procedure-related complications. Follow-up CT within 1 week after vascular plug-assisted RTO showed complete thrombosis of GV and gastrorenal shunts in all patients. Clinical symptoms of HE completely resolved in all seven patients with HE; mean serum NH3 level of 127.4 μmol/L ± 58 (standard deviation) before vascular plug-assisted RTO decreased significantly to 28.1 μmol/L ± 9.8 within 1 week after vascular plug-assisted RTO (P = .002). Eighteen patients who underwent follow-up longer than 2 months showed complete obliteration of GV and gastrorenal shunts at CT and endoscopy. There were no cases of variceal bleeding or HE during mean follow-up of 422 days. Improvement in Child-Pugh score was observed in 12 of 18 (67%) patients 1 month after vascular plug-assisted RTO. Worsening of esophageal varices was observed in four (22%) patients at mean follow-up of 9.4 months. Vascular plug-assisted RTO is technically simple and safe and seems to be clinically effective for treatment of GV and HE.
[Manifestation of first branchial anomaly:56 cases reportrhinitis].
Zhang, B; Chen, L S; Huang, S L; Liang, L; Wu, P N; Zhang, S Y; L, Z M; Liang, L
2016-09-05
Objective: To sum up and conclude manifestation of congenital first branchial anomaly(CFBCA). Method: The clinical data of 56 patients from 2005 to 2015 in our hospital were retrospective reviewed. Result: Manifestation:mass without pain(26.8%),repeated sore and discharge(71.4%),otological symptom(external auditory discharge、hearing loss,28.6%).Eleven cases bacterial sample showed positive result,and most of them show pseudomonas aeruginosa and staphylococcus aureus.Auricular endoscopy typically performed stricture of external auditory canal,cholesteatoma samples accumulated in ear canal,fistula at the conjunction of the bone and cartilage and tympanic membranous attachment.Typical performance of CT(MRI)was that there were cystic,lobulated or tubular abnormal shadow related with ear canal in Pochet's triangle area whose cyst wall or pipe wall could been enhanced in enhanced CT(MRI) scans,and part of that could be connected with skin.The statistical difference between type Oslen and Work and clinical characteristics( P <0.01),and the relationship between type Oslen and Work( P <0.01).Most of Work Ⅰ were cyst type,and these two type often had no infected symptom.Most of them were young patients.Most of Work Ⅱ were sinus and fistula type ,and these two type often had infected symptom.Most of them were teenagers.Part of patients of type Work Ⅱ showed tympanic membranous attachment. Conclusion: CFBCA was rare,and it is more common in young patients and often in left part.It always performed as mass without pain、repeated sore and discharge、external auditory discharge.Most of Work Ⅰ were cyst type,and these two type often had no infected symptom and most of them were young patients .Most of Work Ⅱ were sinus and fistula type,and these two type often had infected symptom and most of them were teenagers.Auricular endoscopy,CT,MRI could help make diagnose.Doctors clinical need to differentiate it with related diseases according to different manifestations. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
[Role and responsibility of multimodal imaging in head and neck cancer].
Gõdény, Mária
2013-09-01
Hungary is first in head and neck cancer mortality in Europe in men and also in women. Head and neck (HN) is a difficult region, its anatomy and also pathology is very complex, various connection points exist between the sites which determine the extension of the disease. Diagnostic algorithms as well as imaging techniques have to be optimized to examine in standard manner. Like most other cancers, prognosis depends largely on the stage of the tumor. Accuracy of tumor detection and evaluation is very important because it affects treatment planning. As non-surgical organ-preserving therapeutic modalities (chemotherapy, chemoradiotherapy, targeted biological therapy) gain general acceptance, the importance of noninvasive diagnostic accuracy as well as radiologic evaluation of the extent of the tumor has increased. Clinical examinations including endoscopy should be combined with radiologic imaging to assess the precise local (T), regional nodal (N), and distant (M) extent of the tumor. Computed tomography (CT) and magnetic resonance imaging (MRI) have become basic tools in the diagnosis of head and neck tumors. They are both useful for assessing deep tumor extensions, able to detect changes missed by endoscopy. It has been shown that the primary determined tumor stage increases in up to 90% of patients after the results of cross sectional imaging. MRI is being increasingly used and has become the gold standard in head and neck cancer for staging, assessing tumor response, finding recurrent tumor and also for treatment planning in radiotherapy. The field strength of MRI scanners has been increasing to 1.5 T and now 3 T with better signal-to-noise ratio, higher resolution images and better tissue diagnosis. Functional MR techniques such as dynamic contrast enhanced MRI (DCE-MRI) and diffusion weighted MRI (DW-MRI) may provide further characterization. PET/CT is beneficial in detecting unsuspected metastatic nodes, distant disease and second primary tumor. PET/CT and MRI both appeared almost similarly accurate in the detection of an occult primary tumor. The effective management of patients depends highly on the competece of radiologists and requires close collaboration between clinical and surgical oncologists, diagnostic and therapeutic radiologists as well as pathologists.
A visual graphic/haptic rendering model for hysteroscopic procedures.
Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer
2006-03-01
Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilises an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organised curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynaecologic endoscopy training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopy factors, current training and accreditation, and proposes a hysteroscopic simulator design that is suitable for educating and training.
CT Colonography (Virtual Colonoscopy)
... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... numerous x-ray beams and a set of electronic x-ray detectors rotate around you, measuring the ...
NASA Astrophysics Data System (ADS)
Mastmeyer, Andre; Wilms, Matthias; Handels, Heinz
2018-03-01
Virtual reality (VR) training simulators of liver needle insertion in the hepatic area of breathing virtual patients often need 4D image data acquisitions as a prerequisite. Here, first a population-based breathing virtual patient 4D atlas is built and second the requirement of a dose-relevant or expensive acquisition of a 4D CT or MRI data set for a new patient can be mitigated by warping the mean atlas motion. The breakthrough contribution of this work is the construction and reuse of population-based, learned 4D motion models.
Villa, C; Olsen, K B; Hansen, S H
2017-09-01
Post-mortem CT scanning (PMCT) has been introduced at several forensic medical institutions many years ago and has proved to be a useful tool. 3D models of bones, skin, internal organs and bullet paths can rapidly be generated using post-processing software. These 3D models reflect the individual physiognomics and can be used to create whole-body 3D virtual animations. In such way, virtual reconstructions of the probable ante-mortem postures of victims can be constructed and contribute to understand the sequence of events. This procedure is demonstrated in two victims of gunshot injuries. Case #1 was a man showing three perforating gunshot wounds, who died due to the injuries of the incident. Whole-body PMCT was performed and 3D reconstructions of bones, relevant internal organs and bullet paths were generated. Using 3ds Max software and a human anatomy 3D model, a virtual animated body was built and probable ante-mortem postures visualized. Case #2 was a man presenting three perforating gunshot wounds, who survived the incident: one in the left arm and two in the thorax. Only CT scans of the thorax, abdomen and the injured arm were provided by the hospital. Therefore, a whole-body 3D model reflecting the anatomical proportions of the patient was made combining the actual bones of the victim with those obtained from the human anatomy 3D model. The resulted 3D model was used for the animation process. Several probable postures were also visualized in this case. It has be shown that in Case #1 the lesions and the bullet path were not consistent with an upright standing position; instead, the victim was slightly bent forward, i.e. he was sitting or running when he was shot. In Case #2, one of the bullets could have passed through the arm and continued into the thorax. In conclusion, specialized 3D modelling and animation techniques allow for the reconstruction of ante-mortem postures based on both PMCT and clinical CT. Copyright © 2017 Elsevier B.V. All rights reserved.
New approaches to virtual environment surgery
NASA Technical Reports Server (NTRS)
Ross, M. D.; Twombly, A.; Lee, A. W.; Cheng, R.; Senger, S.
1999-01-01
This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.
Present status of endoscopy, therapeutic endoscopy and the endoscopy training system in Indonesia.
Makmun, Dadang
2014-04-01
Recently, Indonesia was ranked as the fourth most populous country in the world. Based on 2012 data, 85000 general practitioners and 25000 specialists are in service around the country. Gastrointestinal (GI) disease remains the most common finding in daily practise, in both outpatient and inpatient settings, and ranks fifth in causing mortality in Indonesia. Management of patients with GI disease involves all health-care levels with the main portion in primary health care. Some are managed by specialists in secondary health care or are referred to tertiary health care. GI endoscopy is one of the main diagnostic and therapeutic modalities in the management of GI disease. Development of GI endoscopy in Indonesia started before World War II and, today, many GI endoscopy procedures are conducted in Indonesia, both diagnostic and therapeutic. Based on August 2013 data, there are 515 GI endoscopists in Indonesia. Most GI endoscopists are competent in carrying out basic endoscopy procedures, whereas only a few carry out advanced endoscopy procedures, including therapeutic endoscopy. Recently, the GI endoscopy training system in Indonesia consists of basic GI endoscopy training of 3-6 months held at 10 GI endoscopy training centers. GI endoscopy training is also eligible as part of a fellowship program of consultant gastroenterologists held at six accredited fellowship centers in Indonesia. Indonesian Society for Digestive Endoscopy in collaboration with GI endoscopy training centers in Indonesia and overseas has been working to increase quality and number of GI endoscopists, covering both basic and advanced GI endoscopy procedures. © 2014 The Author. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Nuzzo, Alexandre; Zappa, Magaly; Cazals-Hatem, Dominique; Bouhnik, Yoram
2016-09-01
Mesenteric panniculitis (MP) is mostly an associated sign of an intra-abdominal or systemic inflammatory primary disease. Nevertheless, etiological and differential diagnosis of idiopathic MP can be challenging when an associate primary cause is not in the foreground. We report here the case of an isolated small bowel Crohn's disease, long time considered as idiopathic MP. This patient presented to our department with a 10-year history of acute abdominal symptoms evolving with flare-up and remission. A diagnosis of idiopathic MP was made based on compatible CT-scan features along with normal laboratory tests and upper and lower bowel endoscopies. As symptoms recurred, a steroid course was proposed which dramatically improved his condition for years. Finally, an explorative laparoscopy was performed because of concern of malignancy when he returned to our unit with a steroid refractory flare-up and weight loss, along with MP nodes growing up to 10 mm. Crohn's disease was eventually diagnosed, based on histopathological middle-gut bowel resection and numerous granulomas in mesenteric nodes without necrosis. This case emphasizes the importance of excluding inflammatory intestinal lesions before making the diagnosis of idiopathic MP (fecal calprotectin, magnetic resonance enterography, wireless capsule endoscopy).
Yang, Chuang-Bo; Zhang, Shuang; Jia, Yong-Jun; Duan, Hai-Feng; Ma, Guang-Ming; Zhang, Xi-Rong; Yu, Yong; He, Tai-Ping
2017-04-01
This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat-based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 ± 262.36 mg/mL), CT number at 40 keV (-31.57 ± 16.88 HU) and 140 keV (24.30 ± 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 ± 105.12 mg/mL, 12.99 ± 9.39 HU and 6.19 ± 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0.994 for differentiating cholesterol gallstones from bile. Virtual monochromatic spectral CT images at 40 keV and 140 keV provide significant CT number differences between cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Gastric and enteric anisakiasis successfully treated with Gastrografin therapy: A case report.
Fujikawa, Hiroki; Kuwai, Toshio; Yamaguchi, Toshiki; Miura, Ryoichi; Sumida, Yuki; Takasago, Takeshi; Miyasako, Yuki; Nishimura, Tomoyuki; Iio, Sumio; Imagawa, Hiroki; Yamaguchi, Atsushi; Kouno, Hirotaka; Kohno, Hiroshi
2018-03-16
We report a case of a 59-year-old woman who was diagnosed with gastric and small intestinal anisakiasis, which was successfully treated with endoscopic extraction and Gastrografin therapy. She was admitted to our hospital with epigastric pain and vomiting one day after eating raw fish. She exhibited tenderness in the epigastrium without obvious rebound tenderness or guarding. Computed tomography (CT) demonstrated segmental edema of the intestinal wall with proximal dilatation and a small number of ascites. Because enteric anisakiasis was suspected based on the patient's history of recent raw fish consumption and abdominal CT, we performed gastroscopy and confirmed that nine Anisakis larvae were attached to the gastric mucosa. All of the Anisakis larvae were extracted via endoscopy, and the patient was diagnosed with gastric and enteric anisakiasis. Additionally, in the hospital, we performed ileography twice using Gastrografin, which led to shortened hospital stay. Based on the clinical results of this case, we suggest that Gastrografin therapy is a safe, convenient, and useful method to extract enteric Anisakis larvae.
ERIC Educational Resources Information Center
Orsini-Jones, Marina
2004-01-01
This paper reports on the results of an action research project at Coventry University that consisted of the evaluation of a curriculum innovation supported by the use of the Virtual Learning Environment (VLE) WebCT, i.e. a new module (course): "Academic and Professional Skills for Language Learning". The project was carried out…
NASA Astrophysics Data System (ADS)
Tang, Xiangyang; Yang, Yi; Tang, Shaojie
2013-03-01
Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.
Satou, Shouichi; Aoki, Taku; Kaneko, Junichi; Sakamoto, Yoshihiro; Hasegawa, Kiyoshi; Sugawara, Yasuhiko; Arai, Osamu; Mitake, Tsuyoshi; Miura, Koui; Kokudo, Norihiro
2014-02-01
Real-time virtual sonography is an innovative imaging technology that detects the spatial position of an ultrasound probe and immediately reconstructs a section of computed tomography (CT) and/or magnetic resonance in accordance with the ultrasound image, thereby allowing a real-time comparison of those modalities. A novel intraoperative navigation system for liver resection using real-time virtual sonography has been devised for the detection of tumors and navigation of the resection plane. Sixteen patients with hepatic malignancies (26 tumors in total) were involved in this study, and the system was used intraoperatively. The tumor size ranged 2 to 140 mm (23 mm in median). By the navigation system, operators could refer intraoperative ultrasound image displayed on the television monitor side-by-side with corresponding images of CT and/or magnetic resonance. In addition, the system overlaid preoperative simulation on the CT image and highlighted the extent of resection so as to navigate the resection plane. Because the system used electromagnetic power in the operation room, the feasibility and safety of the system was investigated as well as its validity. The system could be used uneventfully in each operation. All of the 26 tumors scheduled to be resected were detected by the navigation system. The weight of the resected specimen correlated with the preoperatively simulated volume (R = 0.995, P < .0001). The feasibility and safety of the navigation system were confirmed. The system should be helpful for intraoperative tumor detection and navigation of liver resection.
Sakamoto, Takashi; Mitsuzaki, Katsuhiko; Utsunomiya, Daisuke; Matsuda, Katsuhiko; Yamamura, Sadahiro; Urata, Joji; Kawakami, Megumi; Yamashita, Yasuyuki
2012-09-01
Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.
Virtual reality in the operating room of the future.
Müller, W; Grosskopf, S; Hildebrand, A; Malkewitz, R; Ziegler, R
1997-01-01
In cooperation with the Max-Delbrück-Centrum/Robert-Rössle-Klinik (MDC/RRK) in Berlin, the Fraunhofer Institute for Computer Graphics is currently designing and developing a scenario for the operating room of the future. The goal of this project is to integrate new analysis, visualization and interaction tools in order to optimize and refine tumor diagnostics and therapy in combination with laser technology and remote stereoscopic video transfer. Hence, a human 3-D reference model is reconstructed using CT, MR, and anatomical cryosection images from the National Library of Medicine's Visible Human Project. Applying segmentation algorithms and surface-polygonization methods a 3-D representation is obtained. In addition, a "fly-through" the virtual patient is realized using 3-D input devices (data glove, tracking system, 6-DOF mouse). In this way, the surgeon can experience really new perspectives of the human anatomy. Moreover, using a virtual cutting plane any cut of the CT volume can be interactively placed and visualized in realtime. In conclusion, this project delivers visions for the application of effective visualization and VR systems. Commonly known as Virtual Prototyping and applied by the automotive industry long ago, this project shows, that the use of VR techniques can also prototype an operating room. After evaluating design and functionality of the virtual operating room, MDC plans to build real ORs in the near future. The use of VR techniques provides a more natural interface for the surgeon in the OR (e.g., controlling interactions by voice input). Besides preoperative planning future work will focus on supporting the surgeon in performing surgical interventions. An optimal synthesis of real and synthetic data, and the inclusion of visual, aural, and tactile senses in virtual environments can meet these requirements. This Augmented Reality could represent the environment for the surgeons of tomorrow.
Human identification based on cranial computed tomography scan — a case report
Silva, RF; Botelho, TL; Prado, FB; Kawagushi, JT; Daruge Júnior, E; Bérzin, F
2011-01-01
Today, there is increasing use of CT scanning on a clinical basis, aiding in the diagnosis of diseases or injuries. This exam also provides important information that allows identification of individuals. This paper reports the use of a CT scan on the skull, taken when the victim was alive, for the positive identification of a victim of a traffic accident in which the fingerprint analysis was impossible. The authors emphasize that the CT scan is a tool primarily used in clinical diagnosis and may contribute significantly to forensic purpose, allowing the exploration of virtual corpses before the classic autopsy. The use of CT scans might increase the quantity and quality of information involved in the death of the person examined. PMID:21493883
Toepker, Michael; Moritz, Thomas; Krauss, Bernhard; Weber, Michael; Euller, Gordon; Mang, Thomas; Wolf, Florian; Herold, Christian J; Ringl, Helmut
2012-03-01
To evaluate the reliability of attenuation values in virtual non-contrast images (VNC) reconstructed from contrast-enhanced, dual-energy scans performed on a second-generation dual-energy CT scanner, compared to single-energy, non-contrast images (TNC). Sixteen phantoms containing a mixture of contrast agent and water at different attenuations (0-1400 HU) were investigated on a Definition Flash-CT scanner using a single-energy scan at 120 kV and a DE-CT protocol (100 kV/SN140 kV). For clinical assessment, 86 patients who received a dual-phase CT, containing an unenhanced single-energy scan at 120 kV and a contrast enhanced (110 ml Iomeron 400 mg/ml; 4 ml/s) DE-CT (100 kV/SN140 kV) in an arterial (n=43) or a venous phase, were retrospectively analyzed. Mean attenuation was measured within regions of interest of the phantoms and in different tissue types of the patients within the corresponding VNC and TNC images. Paired t-tests and Pearson correlation were used for statistical analysis. For all phantoms, mean attenuation in VNC was 5.3±18.4 HU, with respect to water. In 86 patients overall, 2637 regions were measured in TNC and VNC images, with a mean difference between TNC and VNC of -3.6±8.3 HU. In 91.5% (n=2412) of all cases, absolute differences between TNC and VNC were under 15HU, and, in 75.3% (n=1986), differences were under 10 HU. Second-generation dual-energy CT based VNC images provide attenuation values close to those of TNC. To avoid possible outliers multiple measurements are recommended especially for measurements in the spleen, the mesenteric fat, and the aorta. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Krok, Karen L.; Wagennar, Rebecca Rankin; Kantsevoy, Sergey V.
2016-01-01
Introduction Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. Material and methods Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of capsule endoscopy were compared to endoscopy for the presence and severity of esophageal and gastric varices, PHG and the need for primary prophylaxis. Patients’ preference was assessed by a questionnaire. Results Four (6%) patients were unable to swallow the capsule. Sensitivity, specificity, PPV and NPV of capsule endoscopy for detecting any esophageal varices (92%, 50%, 92%, 50%), large varices (55%, 91%, 75%, 80%), variceal red signs (58%, 87%, 69%, 80%), PHG (95%, 50%, 95%, 50%), and the need for primary prophylaxis (91%, 57%, 78%, 80%) were not optimal, with only moderate agreement (κ) between capsule and upper GI endoscopy. Had only a capsule endoscopy been performed, 12 (21.4%) patients would have received inappropriate treatment. Capsule endoscopy also failed to detect (0/13) gastric varices. The majority of patients ranked capsule endoscopy as more convenient (69%) and their preferred (61%) method. Conclusions Despite the preference expressed by patients for capsule endoscopy, we believe that upper GI endoscopy should remain the preferred screening method for primary prophylaxis. PMID:27186182
Sonnemans, Lianne J P; Kubat, Bela; Prokop, Mathias; Klein, Willemijn M
2018-03-16
To investigate whether virtual autopsy with postmortem CT (PMCT) improves clinical diagnosis of the immediate cause of death. Retrospective observational cohort study. inhospital and out-of-hospital deaths over the age of 1 year in whom virtual autopsy with PMCT and conventional autopsy were performed. forensic cases, postmortal organ donors and cases with incomplete scanning procedures. Cadavers were examined by virtual autopsy with PMCT prior to conventional autopsy. The clinically determined cause of death was recorded before virtual autopsy and was then adjusted with the findings of virtual autopsy. Using conventional autopsy as reference standard, we investigated the increase in sensitivity for immediate cause of death, type of pathology and anatomical system involved before and after virtual autopsy. Tertiary referral centre. 86 cadavers that underwent conventional and virtual autopsy between July 2012 and June 2016. PMCT consisted of brain, cervical spine and chest-abdomen-pelvis imaging. Conventional autopsy consisted of thoracoabdominal examination with/without brain autopsy. Increase in sensitivity for the immediate cause of death, type of pathology (infection, haemorrhage, perfusion disorder, other or not assigned) and anatomical system (pulmonary, cardiovascular, gastrointestinal, other or not assigned) involved, before and after virtual autopsy. Using PMCT, the sensitivity for immediate cause of death increased with 12% (95% CI 2% to 22%) from 53% (41% to 64%) to 64% (53% to 75%), with 18% (9% to 27%) from 65% (54% to 76%) to 83% (73% to 91%) for type of pathology and with 19% (9% to 30%) from 65% (54% to 76%) to 85% (75% to 92%) for anatomical system. While unenhanced PMCT is an insufficient substitute for conventional autopsy, it can improve diagnosis of cause of death over clinical diagnosis alone and should therefore be considered whenever autopsy is not performed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Endocytoscopic findings of lymphomas of the stomach
2013-01-01
Background The gastric lesions of various lymphomas were observed at the cellular level using endocytoscopy. Methods Endocytoscopy and magnifying endoscopy with narrow band imaging (NBI) were performed in 17 patients with lymphomas of the stomach. The lesions consisted of 7 with low-grade mucosa-associated lymphoid tissue (MALT), 5 with gastric involvement by adult T-cell leukemia/lymphoma (ATLL), 4 with diffuse large B-cell lymphoma (DLBCL), and 1 with peripheral T-cell lymphoma. Results On conventional endoscopy, 9 were classified as having superficial spreading type, 7 were mass-forming type, and 1 was diffuse infiltrating type. Anti-H. pylori treatment was given in the 7 MALT lymphoma cases. NBI magnification endoscopy invariably showed dilatation or ballooning and destruction of gastric pits and elongation and distortion in microvessels. Endocytoscopy showed mucosal aggregation of interstitial cellular elements in almost all gastric lymphoma cases. The nuclear diversity in size and configuration was exclusively seen in gastric lymphomas other than MALT lymphoma, whereas the nuclei of MALT lymphoma cells were regular and small to moderate in size. Inter-glandular infiltration by lymphomatous cell elements was frequently observed in MALT lymphoma and DLBCL, but it was uncommon in peripheral gastric T-cell malignancies. Endocytoscopy could identify the disease-specific histology, the lymphoepithelial origin, as inter-glandular infiltration of cellular components in MALT lymphoma and the possibly related DLBCL cases. Complete regression (CR) was observed in 2 of the 7 MALT lymphoma patients. In the 2 patients with CR who underwent repeat endocytoscopy, the ultra-high magnification abnormalities returned to normal, while they were unchanged in those without tumor regression. Conclusions On endocytoscopy, intra-glandular aggregation of cellular components was invariably identified in lymphomas of the stomach. Nuclear regularity in size and configuration may indicate the cytological grade, differentiating the indolent low-grade from aggressive lymphoproliferative diseases. The inter-glandular infiltration seen on endocytoscopy can indicate the lymphoepithelial lesions seen in MALT lymphoma and related DLBCL. Endocytoscopy would be applicable for virtual histopathological diagnosis of different lymphoproliferative disorders and their clinical assessment during ongoing endoscopy. PMID:24369830
Clinical findings and results of diagnostic imaging in 82 dogs with gastrointestinal ulceration.
Fitzgerald, E; Barfield, D; Lee, K C L; Lamb, C R
2017-04-01
To describe clinical and imaging findings in dogs with confirmed gastrointestinal ulceration, to compare findings in dogs with perforated and non-perforated ulcers and to estimate the sensitivities of radiography, ultrasonography and computed tomography (CT) for gastrointestinal ulceration and perforation. Retrospective review of medical records of 82 dogs that had a macroscopic ulcer in the gastric or intestinal mucosa diagnosed directly at endoscopy, surgery or necropsy and had survey radiography, ultrasonography or a CT scan of the abdomen during the same period of hospitalisation. The most frequent clinical signs were vomiting in 88% dogs, haematemesis in 32%, melaena in 31% and weight loss in 7%. The most frequent imaging findings in dogs with non-perforated ulcers were gastrointestinal mural lesion in 56%, mucosal defect compatible with an ulcer in 44% and peritoneal fluid in 21%. In dogs with perforated ulcers the most frequent imaging findings were peritoneal fluid in 83%, gastrointestinal mural lesion in 48%, peritoneal gas in 31% and mucosal defect compatible with an ulcer in 29%. Sensitivities of radiography, ultrasonography and CT were 30, 65 and 67% in dogs with non-perforated ulcers and 79, 86 and 93% in dogs with perforated ulcers, respectively. In dogs with non-perforated ulcers, survey radiography was usually negative whereas ultrasonography and CT frequently enabled detection of the site of the ulcer; in dogs with perforated ulcers, radiography was frequently positive for peritoneal gas and CT was a sensitive modality for both the ulcer and signs of perforation. © 2017 British Small Animal Veterinary Association.
Correlation of Radiological and Endoscopic Findings in Patients Presenting with Dysphagia.
Sachdeva, Kavita; Kaul, Vineet
2017-03-01
Dysphagia is a common symptom with diverse etiology in otolaryngology. In the present study clinicopathological, radiological and endoscopic evaluation of patients was done in a tertiary care hospital in patients presenting with dysphagia. A prospective nonrandomized observational study was carried out on total of 80 cases having dysphagia during March 2015 to August 2016. In the present study, out of 80 patients, youngest case was a three years old child while oldest case was an 85 years old female. The mean age was 48.3 ± 20.3 years. The majority of cases were in age group 41-59 years (35%). Male to female ratio was 2.33:1. The mean duration of illness was 15.44 weeks. 15% of patients had absolute dysphagia. For detecting the lesion, Barium swallow study (BSS) showed a total sensitivity of 49.05% (n = 53), Computerised Tomography (CT) showed a total sensitivity of 85.70% (n = 49), plain skiagram neck & chest showed a total sensitivity of 88.88% (n = 9) and endoscopy was the most sensitive test overall as it showed a total sensitivity of 98.75% (n = 80). No complications were reported with either rigid or flexible endoscopy. Dysphagia is a common presenting complaint in otolaryngology with cases coming directly or being referred from other specialities. Males are more commonly affected than females and incidence of malignancy increases with age. Endoscopy can become the first screening test in dysphagia due to its high sensitivity and low risk of complications, with radiological tests being done in an adjunct manner.
Image-based path planning for automated virtual colonoscopy navigation
NASA Astrophysics Data System (ADS)
Hong, Wei
2008-03-01
Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J; Szczykutowicz, T; Bayouth, J
Purpose: To compare the ability of two dual-energy CT techniques, a novel split-filter single-source technique of superior temporal resolution against an established sequential-scan technique, to remove iodine contrast from images with minimal impact on CT number accuracy. Methods: A phantom containing 8 tissue substitute materials and vials of varying iodine concentrations (1.7–20.1 mg I /mL) was imaged using a Siemens Edge CT scanner. Dual-energy virtual non-contrast (VNC) images were generated using the novel split-filter technique, in which a 120kVp spectrum is filtered by tin and gold to create high- and low-energy spectra with < 1 second temporal separation between themore » acquisition of low- and high-energy data. Additionally, VNC images were generated with the sequential-scan technique (80 and 140kVp) for comparison. CT number accuracy was evaluated for all materials at 15, 25, and 35mGy CTDIvol. Results: The spectral separation was greater for the sequential-scan technique than the split-filter technique with dual-energy ratios of 2.18 and 1.26, respectively. Both techniques successfully removed iodine contrast, resulting in mean CT numbers within 60HU of 0HU (split-filter) and 40HU of 0HU (sequential-scan) for all iodine concentrations. Additionally, for iodine vials of varying diameter (2–20 mm) with the same concentration (9.9 mg I /mL), the system accurately detected iodine for all sizes investigated. Both dual-energy techniques resulted in reduced CT numbers for bone materials (by >400HU for the densest bone). Increasing the imaging dose did not improve the CT number accuracy for bone in VNC images. Conclusion: VNC images from the split-filter technique successfully removed iodine contrast. These results demonstrate a potential for improving dose calculation accuracy and reducing patient imaging dose, while achieving superior temporal resolution in comparison sequential scans. For both techniques, inaccuracies in CT numbers for bone materials necessitate consideration for radiation therapy treatment planning.« less
Martín-Vega, Daniel; Simonsen, Thomas J; Hall, Martin J R
2017-05-01
Metamorphosis of cyclorrhaphous flies takes place inside a barrel-like puparium, formed by the shrinking, hardening and darkening of the third-instar larval cuticle. The opacity of this structure hampers the visualization of the morphological changes occurring inside and therefore a full understanding of the metamorphosis process. Here, we use micro-computed tomography (micro-CT) to describe the internal morphological changes that occur during metamorphosis of the blow fly, Calliphora vicina Robineau-Desvoidy 1830 (Diptera: Calliphoridae) at a greater temporal resolution than anything hitherto published. The morphological changes were documented at 10% intervals of the total intra-puparial period, and down to 2.5% intervals during the first 20% interval, when the most dramatic morphological changes occur. Moreover, the development of an internal gas bubble, which plays an essential role during early metamorphosis, was further investigated with X-ray images and micro-CT virtual sections. The origin of this gas bubble has been largely unknown, but micro-CT virtual sections show that it is connected to one of the main tracheal trunks. Micro-CT virtual sections also provided enough resolution for determining the completion of the larval-pupal and pupal-adult apolyses, thus enabling an accurate timing of the different intra-puparial life stages. The prepupal, pupal, and pharate adult stages last for 7.5%, 22.5%, and 70% of the total intra-puparial development, respectively. Furthermore, we provide for the first time quantitative data on the development of two organ systems of the blow fly: the alimentary canal and the indirect flight muscles. There is a significant and negative correlation between the volume of the indirect flight muscles and the pre-helicoidal region of the midgut during metamorphosis. The latter occupies a large portion of the thorax during the pupal stage but narrows progressively as the indirect flight muscles increase in volume during the development of the pharate adult. © 2017 The Authors Journal of Morphology Published by Wiley Periodicals, Inc.
Simonsen, Thomas J.; Hall, Martin J. R.
2017-01-01
Abstract Metamorphosis of cyclorrhaphous flies takes place inside a barrel‐like puparium, formed by the shrinking, hardening and darkening of the third‐instar larval cuticle. The opacity of this structure hampers the visualization of the morphological changes occurring inside and therefore a full understanding of the metamorphosis process. Here, we use micro‐computed tomography (micro‐CT) to describe the internal morphological changes that occur during metamorphosis of the blow fly, Calliphora vicina Robineau‐Desvoidy 1830 (Diptera: Calliphoridae) at a greater temporal resolution than anything hitherto published. The morphological changes were documented at 10% intervals of the total intra‐puparial period, and down to 2.5% intervals during the first 20% interval, when the most dramatic morphological changes occur. Moreover, the development of an internal gas bubble, which plays an essential role during early metamorphosis, was further investigated with X‐ray images and micro‐CT virtual sections. The origin of this gas bubble has been largely unknown, but micro‐CT virtual sections show that it is connected to one of the main tracheal trunks. Micro‐CT virtual sections also provided enough resolution for determining the completion of the larval‐pupal and pupal‐adult apolyses, thus enabling an accurate timing of the different intra‐puparial life stages. The prepupal, pupal, and pharate adult stages last for 7.5%, 22.5%, and 70% of the total intra‐puparial development, respectively. Furthermore, we provide for the first time quantitative data on the development of two organ systems of the blow fly: the alimentary canal and the indirect flight muscles. There is a significant and negative correlation between the volume of the indirect flight muscles and the pre‐helicoidal region of the midgut during metamorphosis. The latter occupies a large portion of the thorax during the pupal stage but narrows progressively as the indirect flight muscles increase in volume during the development of the pharate adult. PMID:28182298
Goh, Khean-Lee
2011-05-01
Gastrointestinal endoscopy started in the early 1970s in Malaysia with the help of Japanese doctors. It has evolved over the past 30 years. The gastrointestinal endoscopy unit at the University of Malaya Medical Centre has been in the forefront in providing endoscopy services to patients as well as training doctors in endoscopy in the country. In recent years, trainees have included those from neighboring countries in South-East Asia. Among our most significant achievements is the organization of regular international therapeutic endoscopy workshops since 1993 where leading endoscopists from throughout the world have accepted our invitation as teaching faculty. In 2008, the World Organization of Digestive Endoscopy accorded the high distinction of Centre of Excellence to the endoscopy unit of the University of Malaya Medical Centre. © 2011 The Author. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.
SU-F-T-436: A Method to Evaluate Dosimetric Properties of SFGRT in Eclipse TPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, M; Tobias, R; Pankuch, M
Purpose: The objective was to develop a method for dose distribution calculation of spatially-fractionated-GRID-radiotherapy (SFGRT) in Eclipse treatment-planning-system (TPS). Methods: Patient treatment-plans with SFGRT for bulky tumors were generated in Varian Eclipse version11. A virtual structure based on the GRID pattern was created and registered to a patient CT image dataset. The virtual GRID structure was positioned on the iso-center level together with matching beam geometries to simulate a commercially available GRID block made of brass. This method overcame the difficulty in treatment-planning and dose-calculation due to the lack o-the option to insert a GRID block add-on in Eclipse TPS.more » The patient treatment-planning displayed GRID effects on the target, critical structures, and dose distribution. The dose calculations were compared to the measurement results in phantom. Results: The GRID block structure was created to follow the beam divergence to the patient CT images. The inserted virtual GRID block made it possible to calculate the dose distributions and profiles at various depths in Eclipse. The virtual GRID block was added as an option to TPS. The 3D representation of the isodose distribution of the spatially-fractionated beam was generated in axial, coronal, and sagittal planes. Physics of GRID can be different from that for fields shaped by regular blocks because the charge-particle-equilibrium cannot be guaranteed for small field openings. Output factor (OF) measurement was required to calculate the MU to deliver the prescribed dose. The calculated OF based on the virtual GRID agreed well with the measured OF in phantom. Conclusion: The method to create the virtual GRID block has been proposed for the first time in Eclipse TPS. The dosedistributions, in-plane and cross-plane profiles in PTV can be displayed in 3D-space. The calculated OF’s based on the virtual GRID model compare well to the measured OF’s for SFGRT clinical use.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp; Shirono, Ryozo; Takechi, Katsuya
Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differencesmore » in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.« less
Applicability of three-dimensional imaging techniques in fetal medicine*
Werner Júnior, Heron; dos Santos, Jorge Lopes; Belmonte, Simone; Ribeiro, Gerson; Daltro, Pedro; Gasparetto, Emerson Leandro; Marchiori, Edson
2016-01-01
Objective To generate physical models of fetuses from images obtained with three-dimensional ultrasound (3D-US), magnetic resonance imaging (MRI), and, occasionally, computed tomography (CT), in order to guide additive manufacturing technology. Materials and Methods We used 3D-US images of 31 pregnant women, including 5 who were carrying twins. If abnormalities were detected by 3D-US, both MRI and in some cases CT scans were then immediately performed. The images were then exported to a workstation in DICOM format. A single observer performed slice-by-slice manual segmentation using a digital high resolution screen. Virtual 3D models were obtained from software that converts medical images into numerical models. Those models were then generated in physical form through the use of additive manufacturing techniques. Results Physical models based upon 3D-US, MRI, and CT images were successfully generated. The postnatal appearance of either the aborted fetus or the neonate closely resembled the physical models, particularly in cases of malformations. Conclusion The combined use of 3D-US, MRI, and CT could help improve our understanding of fetal anatomy. These three screening modalities can be used for educational purposes and as tools to enable parents to visualize their unborn baby. The images can be segmented and then applied, separately or jointly, in order to construct virtual and physical 3D models. PMID:27818540
NASA Astrophysics Data System (ADS)
Soler, Luc; Marescaux, Jacques
2006-04-01
Technological innovations of the 20 th century provided medicine and surgery with new tools, among which virtual reality and robotics belong to the most revolutionary ones. Our work aims at setting up new techniques for detection, 3D delineation and 4D time follow-up of small abdominal lesions from standard mecial images (CT scsan, MRI). It also aims at developing innovative systems making tumor resection or treatment easier with the use of augmented reality and robotized systems, increasing gesture precision. It also permits a realtime great distance connection between practitioners so they can share a same 3D reconstructed patient and interact on a same patient, virtually before the intervention and for real during the surgical procedure thanks to a telesurgical robot. In preclinical studies, our first results obtained from a micro-CT scanner show that these technologies provide an efficient and precise 3D modeling of anatomical and pathological structures of rats and mice. In clinical studies, our first results show the possibility to improve the therapeutic choice thanks to a better detection and and representation of the patient before performing the surgical gesture. They also show the efficiency of augmented reality that provides virtual transparency of the patient in real time during the operative procedure. In the near future, through the exploitation of these systems, surgeons will program and check on the virtual patient clone an optimal procedure without errors, which will be replayed on the real patient by the robot under surgeon control. This medical dream is today about to become reality.
Pineal region tumors: computed tomographic-pathologic spectrum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Futrell, N.N.; Osborn, A.G.; Cheson. B.D.
While several computed tomographic (CT) studies of posterior third ventricular neoplasms have included descriptions of pineal tumors, few reports have concentrated on these uncommon lesions. Some authors have asserted that the CT appearance of many pineal tumors is virtually pathognomonic. A series of nine biopsy-proved pineal gland and eight other presumed tumors is presented that illustrates their remarkable heterogeneity in both histopathologic and CT appearance. These tumors included germinomas, teratocarcinomas, hamartomas, and other varieties. They had variable margination, attentuation, calcification, and suprasellar extension. Germinomas have the best response to radiation therapy. Biopsy of pineal region tumors is now feasible andmore » is recommended for treatment planning.« less
3D printing from cardiovascular CT: a practical guide and review
Birbara, Nicolette S.; Hussain, Tarique; Greil, Gerald; Foley, Thomas A.; Pather, Nalini
2017-01-01
Current cardiovascular imaging techniques allow anatomical relationships and pathological conditions to be captured in three dimensions. Three-dimensional (3D) printing, or rapid prototyping, has also become readily available and made it possible to transform virtual reconstructions into physical 3D models. This technology has been utilised to demonstrate cardiovascular anatomy and disease in clinical, research and educational settings. In particular, 3D models have been generated from cardiovascular computed tomography (CT) imaging data for purposes such as surgical planning and teaching. This review summarises applications, limitations and practical steps required to create a 3D printed model from cardiovascular CT. PMID:29255693
den Harder, A M; Bangert, F; van Hamersvelt, R W; Leiner, T; Milles, Julien; Schilham, A M R; Willemink, M J; de Jong, P A
2017-12-01
To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm 3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. • Pulmonary nodule volumes were measured on virtual non-contrast and mono-energetic reconstructions • Mono-energetic reconstructions showed that higher attenuation results in larger volumes • This may explain the reported nodule volume underestimation on non-contrast enhanced CT • Mostly metastatic pulmonary nodules were evaluated, results might differ for benign nodules.
Viewpoints on Medical Image Processing: From Science to Application
Deserno (né Lehmann), Thomas M.; Handels, Heinz; Maier-Hein (né Fritzsche), Klaus H.; Mersmann, Sven; Palm, Christoph; Tolxdorff, Thomas; Wagenknecht, Gudrun; Wittenberg, Thomas
2013-01-01
Medical image processing provides core innovation for medical imaging. This paper is focused on recent developments from science to applications analyzing the past fifteen years of history of the proceedings of the German annual meeting on medical image processing (BVM). Furthermore, some members of the program committee present their personal points of views: (i) multi-modality for imaging and diagnosis, (ii) analysis of diffusion-weighted imaging, (iii) model-based image analysis, (iv) registration of section images, (v) from images to information in digital endoscopy, and (vi) virtual reality and robotics. Medical imaging and medical image computing is seen as field of rapid development with clear trends to integrated applications in diagnostics, treatment planning and treatment. PMID:24078804
Confocal laser endomicroscopy in the "in vivo" histological diagnosis of the gastrointestinal tract.
De Palma, Giovanni D
2009-12-14
Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope, or into trans-endoscopic probes, a technique now known as confocal endomicroscopy or confocal laser endomicroscopy. This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy, and has stimulated significant interest in the application of this technique in clinical gastroenterology. This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future, particularly in the screening or surveillance of gastrointestinal neoplasia.
Advanced endoscopic imaging to improve adenoma detection
Neumann, Helmut; Nägel, Andreas; Buda, Andrea
2015-01-01
Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092
Viewpoints on Medical Image Processing: From Science to Application.
Deserno Né Lehmann, Thomas M; Handels, Heinz; Maier-Hein Né Fritzsche, Klaus H; Mersmann, Sven; Palm, Christoph; Tolxdorff, Thomas; Wagenknecht, Gudrun; Wittenberg, Thomas
2013-05-01
Medical image processing provides core innovation for medical imaging. This paper is focused on recent developments from science to applications analyzing the past fifteen years of history of the proceedings of the German annual meeting on medical image processing (BVM). Furthermore, some members of the program committee present their personal points of views: (i) multi-modality for imaging and diagnosis, (ii) analysis of diffusion-weighted imaging, (iii) model-based image analysis, (iv) registration of section images, (v) from images to information in digital endoscopy, and (vi) virtual reality and robotics. Medical imaging and medical image computing is seen as field of rapid development with clear trends to integrated applications in diagnostics, treatment planning and treatment.
Virtual Planning of a Complex Three-Part Bimaxillary Osteotomy
Anghinoni, Marilena Laura
2017-01-01
In maxillofacial surgery, every patient presents special problems requiring careful evaluation. Conventional methods to study the deformities are still reliable, but the advent of tridimensional (3D) imaging, especially computed tomography (CT) scan and laser scanning of casts, created the opportunity to better understanding the skeletal support and the soft tissue structures. Nowadays, virtual technologies are increasingly employed in maxillofacial surgery and demonstrated precision and reliability. However, in complex surgical procedures, these new technologies are still controversial. Especially in the less frequent cases of three-part maxillary surgery, the experience is limited, and scientific literature cannot give a clear support. This paper presents the case of a young patient affected by a complex long face dentofacial deformity treated by a bimaxillary surgery with three-part segmentation of the maxilla. The operator performed the surgical study completely with a virtual workflow. Pre- and postoperative CT scan and optical scanning of plaster models were collected and compared. Every postoperatory maxillary piece was superimposed with the presurgical one, and the differences were examined in a color-coded map. Only mild differences were found near the osteotomy lines, when the bony surface and the teeth demonstrated an excellent coincidence. PMID:29318057
Monte Carlo modeling of light propagation in the human head for applications in sinus imaging
Cerussi, Albert E.; Mishra, Nikhil; You, Joon; Bhandarkar, Naveen; Wong, Brian
2015-01-01
Abstract. Sinus blockages are a common reason for physician visits, affecting one out of seven people in the United States, and often require medical treatment. Diagnosis in the primary care setting is challenging because symptom criteria (via detailed clinical history) plus objective imaging [computed tomography (CT) or endoscopy] are recommended. Unfortunately, neither option is routinely available in primary care. We previously demonstrated that low-cost near-infrared (NIR) transillumination correlates with the bulk findings of sinus opacity measured by CT. We have upgraded the technology, but questions of source optimization, anatomical influence, and detection limits remain. In order to begin addressing these questions, we have modeled NIR light propagation inside a three-dimensional adult human head constructed via CT images using a mesh-based Monte Carlo algorithm (MMCLAB). In this application, the sinus itself, which when healthy is a void region (e.g., nonscattering), is the region of interest. We characterize the changes in detected intensity due to clear (i.e., healthy) versus blocked sinuses and the effect of illumination patterns. We ran simulations for two clinical cases and compared simulations with measurements. The simulations presented herein serve as a proof of concept that this approach could be used to understand contrast mechanisms and limitations of NIR sinus imaging. PMID:25781310
Shimamoto, Yoko; Harima, Yohei
2016-04-18
The clinical manifestations of eosinophilic gastroenteritis are nonspecific and vary depending on which layer of the gastrointestinal tract is involved. Computed tomography (CT) is valuable for detecting and characterizing gastrointestinal wall abnormalities. We report a case of eosinophilic gastroenteritis that formed a chamber in the rigid duodenal wall of a 67-year-old woman. Abdominal CT showed symmetrical wall thickening of the gastric antrum and duodenal bulb, and the bowel walls consisted of 2 continuous, symmetrically stratified layers. There was a chamber mimicking a giant ulcer at the orifice of the descending duodenum. Eosinophilic inflammation was present through this rigid wall of the descending duodenum, accompanied by perienteric inflammation, which infiltrated the anterior pararenal space, gall bladder, and right colic flexure. Gastrointestinal endoscopy showed spotty erosions and reddish mucosa, with the edematous gastric antrum and duodenal bulb narrowed at their lumens. Just beyond the supraduodenal angle at the orifice of the descending duodenum, there was a chamber with only minor mucosal changes, and it was not a duodenal ulcer. Endoscopic biopsy of the duodenum showed intramucosal eosinophilic infiltration. Treatment with prednisolone resulted in normalization of radiologic and endoscopic abnormalities. We present a case of eosinophilic gastroenteritis with both mucosal and muscular involvement. CT imaging and endoscopic examination confirmed the diagnosis.
Monte Carlo modeling of light propagation in the human head for applications in sinus imaging
NASA Astrophysics Data System (ADS)
Cerussi, Albert E.; Mishra, Nikhil; You, Joon; Bhandarkar, Naveen; Wong, Brian
2015-03-01
Sinus blockages are a common reason for physician visits, affecting one out of seven people in the United States, and often require medical treatment. Diagnosis in the primary care setting is challenging because symptom criteria (via detailed clinical history) plus objective imaging [computed tomography (CT) or endoscopy] are recommended. Unfortunately, neither option is routinely available in primary care. We previously demonstrated that low-cost near-infrared (NIR) transillumination correlates with the bulk findings of sinus opacity measured by CT. We have upgraded the technology, but questions of source optimization, anatomical influence, and detection limits remain. In order to begin addressing these questions, we have modeled NIR light propagation inside a three-dimensional adult human head constructed via CT images using a mesh-based Monte Carlo algorithm (MMCLAB). In this application, the sinus itself, which when healthy is a void region (e.g., nonscattering), is the region of interest. We characterize the changes in detected intensity due to clear (i.e., healthy) versus blocked sinuses and the effect of illumination patterns. We ran simulations for two clinical cases and compared simulations with measurements. The simulations presented herein serve as a proof of concept that this approach could be used to understand contrast mechanisms and limitations of NIR sinus imaging.
[A Case of Surgery after Chemotherapy for Cecal Cancer with Onset of the Stenosis of the Colostomy].
Kono, Teppei; Yokomizo, Hajime; Yano, Yuki; Okayama, Sachiyo; Satake, Masaya; Yamada, Yasufumi; Ida, Arika; Usui, Takebumi; Yamaguchi, Kentaro; Shiozawa, Shunichi; Yoshimatsu, Kazuhiko; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko
2018-02-01
The patient was 55-year-old woman, undergoing Hartmann operation by the sigmoid colon diverticulum perforation, 2 years later visited our hospital with abdominal pain. Although lower endoscopy and histological examination could not be performed due to stoma stenosis, we diagnosed cecal carcinoma, liver metastasis, distant lymph node metastasis from CT and PET-CT, CapeOX plus Bmabtherapy and IRIS plus Bmabtherapy were performed. After that, repeated intestinal obstruction due to exacerbated stoma stenosis, metastatic lesion increased in CT examination, furthermore the patient had hope of stoma closure, we decided to resect the primacy tumor, performed subtotal colonectomy and stoma closure. Pathological diagnosis revealed RAS wild type. After surgery, Pmabplus CPT-11 therapy was performed and the metastatic lesion was temporarily shrunk but re-exacerbated, the patient died 2 years 2 months after the first treatment started, 7 months after the primary tumor resection. In the treatment of colorectal cancer, when metastatic lesion is unresectable, chemotherapy is often carried out except when the primary tumor is symptomatic. In our case, although the primary tumor was asymptomatic, an intestinal obstruction due to stoma stenosis was developed and it was necessary to examine whether to use anti-EGFR antibody drugs, therefore we performed operation.
Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua
2016-10-01
Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in planning pelvic surgeries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mulder, Chris J J; Jacobs, Maarten A J M; Leicester, Roger J; Nageshwar Reddy, D; Shepherd, Libby E A; Axon, Anthony T; Waye, Jerome D
2013-07-01
A dedicated digestive disease endoscopy unit is structurally and functionally differentiating rapidly as a result of increasing diagnostic and therapeutic possibilities in the last 10-20 years. Publications with practical details are scarce, imposing a challenge in the construction of such a unit. The lack of authoritative information about endoscopy unit design means that architects produce their own design with or without consulting endoscopists working in such a unit. A working group of the World Endoscopy Organization discussed and outlined a practical approach fordesign and construction of a modern endoscopy unit. Designing the layout is extremely important, necessitating thoughtful planning to provide comfort to the endoscopy staff and patients, and efficient data archiving and transmission during endoscopic services. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
TU-AB-202-03: Prediction of PET Transfer Uncertainty by DIR Error Estimating Software, AUTODIRECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chen, J; Phillips, J
2016-06-15
Purpose: Deformable image registration (DIR) is a powerful tool, but DIR errors can adversely affect its clinical applications. To estimate voxel-specific DIR uncertainty, a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), has been developed and validated. This work tests the ability of this software to predict uncertainty for the transfer of standard uptake values (SUV) from positron-emission tomography (PET) with DIR. Methods: Virtual phantoms are used for this study. Each phantom has a planning computed tomography (CT) image and a diagnostic PET-CT image set. A deformation was digitally applied to the diagnostic CT to create the planningmore » CT image and establish a known deformation between the images. One lung and three rectum patient datasets were employed to create the virtual phantoms. Both of these sites have difficult deformation scenarios associated with them, which can affect DIR accuracy (lung tissue sliding and changes in rectal filling). The virtual phantoms were created to simulate these scenarios by introducing discontinuities in the deformation field at the lung rectum border. The DIR algorithm from Plastimatch software was applied to these phantoms. The SUV mapping errors from the DIR were then compared to that predicted by AUTODIRECT. Results: The SUV error distributions closely followed the AUTODIRECT predicted error distribution for the 4 test cases. The minimum and maximum PET SUVs were produced from AUTODIRECT at 95% confidence interval before applying gradient-based SUV segmentation for each of these volumes. Notably, 93.5% of the target volume warped by the true deformation was included within the AUTODIRECT-predicted maximum SUV volume after the segmentation, while 78.9% of the target volume was within the target volume warped by Plastimatch. Conclusion: The AUTODIRECT framework is able to predict PET transfer uncertainty caused by DIR, which enables an understanding of the associated target volume uncertainty.« less
Fayad, Laura M; Johnson, Pamela; Fishman, Elliot K
2005-01-01
Computed tomography (CT) plays an important role in the evaluation of musculoskeletal disease in the pediatric patient. With the advent of high-performance 16-section multidetector CT, images can be produced with subsecond gantry rotation times and with submillimeter acquisition, which yields true isotropic high-resolution volume data sets; these features are not attainable with older spiral CT technology. Such capabilities are particularly helpful in the evaluation of pediatric patients by virtually eliminating the need for sedation and minimizing dependence on patient cooperation. The role of three-dimensional (3D) volume imaging in the evaluation of pediatric musculoskeletal disease continues to evolve, with this technique becoming increasingly important in detection and characterization of lesions as well as in decisions about patient care. Specific designs and protocols for multidetector CT studies can be selected to minimize radiation dose to the patient. Principal clinical applications of 3D CT in evaluation of the pediatric musculoskeletal system include developmental abnormalities, trauma, neoplasms, and postoperative imaging.
2001-09-01
coefficient and propulsive efficiency showed that these parameters are virtually the same for both TE conditions (cT 0 40 and η 0 21). As a conclusion...difference in the way the two codes work, they yielded virtually the same solution. This shows that, for a reasonably small time step, whether the boundary... Biblioteca Sao Jose dos Campos - SP - Brazil iab@bibl.ita.cta.br 5. Prof. Max F. Platzer Chair, Department of Aeronautics & Astronautics - Naval
Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P
2007-12-01
Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.
Diagnosis and management of a retrobulbar abscess of periapical origin in a domestic rabbit.
Ward, Michelle L
2006-09-01
Retrobulbar abscessation is the most common orbital disease of rabbits, and the lesions are notoriously difficult to treat successfully. This article describes the diagnosis, surgical treatment, and long-term management of an extensive abscess located within the right maxilla and retrobulbar space of a domestic rabbit. Preoperative assessment and long-term monitoring were achieved with a combination of radiography, ophthalmic ultrasonography, and CT. Extraoral rigid endoscopy via a fenestration in the maxilla was used to facilitate surgical debridement of the lesion, and extraction of multiple cheek teeth has been fundamental to achieving control. The long-term use of topical and systemic antibiotic preparations and nonsteroidal anti-inflammatory medication is discussed.
Breast Cancer Metastasis to the Stomach That Was Diagnosed after Endoscopic Submucosal Dissection.
Kita, Masahide; Furukawa, Masashi; Iwamuro, Masaya; Hori, Keisuke; Kawahara, Yoshiro; Taira, Naruto; Nogami, Tomohiro; Shien, Tadahiko; Tanaka, Takehiro; Doihara, Hiroyoshi; Okada, Hiroyuki
2016-01-01
A 52-year-old woman presented with stage IIB primary breast cancer (cT2N1M0), which was treated using neoadjuvant chemotherapy (epirubicin, cyclophosphamide, and paclitaxel). However, the tumor persisted in patchy areas; therefore, we performed modified radical mastectomy and axillary lymph node dissection. Routine endoscopy at 8 months revealed a depressed lesion on the gastric angle's greater curvature, and histology revealed signet ring cell proliferation. We performed endoscopic submucosal dissection for gastric cancer, although immunohistochemistry revealed that the tumor was positive for estrogen receptor, mammaglobin, and gross cystic disease fluid protein-15 (E-cadherin-negative). Therefore, we revised the diagnosis to gastric metastasis from the breast cancer.
Perforated Tuberculosis Lymphadenitis
Cataño, Juan; Cardeño, John
2013-01-01
A 26-year-old man (human immunodeficiency virus-positive and not taking highly active antiretroviral treatment [HAART]) presented to the emergency room with 2 months of malaise, 20 kg weight loss, high spiking fevers, generalized lymph nodes, night sweats, dry cough, and chest pain when swallowing. On physical examination, he had multiple cervical lymphadenopathies. Suspecting a systemic opportunistic infection, a contrasted chest computed tomography (CT) was done, showing an esophageal to mediastinum fistulae. Two days after admission, a fluoroscopic contrasted endoscopy was done that showed two esophageal fistulae from scrofula to esophagus and then, to mediastinum. A bronchoalveolar lavage and a cervical lymphadenopathy biopsy were done, both showing multiple acid-fast bacillae, where cultures grew Mycobacterium tuberculosis. PMID:23740190
O'Neill, Marisol; Huang, Gene O; Lamb, Dolores J
2017-12-01
The murine penis model has enriched our understanding of anomalous penile development. The morphologic characterization of the murine penis using conventional serial sectioning methods is labor intensive and prone to errors. To develop a novel application of micro-computerized tomography (micro-CT) with iodine staining for rapid, non-destructive morphologic study of murine penis structure. Penises were dissected from 10 adult wild-type mice and imaged using micro-CT with iodine staining. Images were acquired at 5-μm spatial resolution on a Bruker SkyScan 1272 micro-CT system. After images were acquired, the specimens were washed of any remaining iodine and embedded in paraffin for conventional histologic examination. Histologic and micro-CT measurements for all specimens were made by 2 independent observers. Measurements of penile structures were made on virtual micro-CT sections and histologic slides. The Lin concordance correlation coefficient demonstrated almost perfect strength of agreement for interobserver variability for histologic section (0.9995, 95% CI = 0.9990-0.9997) and micro-CT section (0.9982, 95% CI = 0.9963-0.9991) measurements. Bland-Altman analysis for agreement between the 2 modalities of measurement demonstrated mean differences of -0.029, 0.022, and -0.068 mm for male urogenital mating protuberance, baculum, and penile glans length, respectively. There did not appear to be a bias for overestimation or underestimation of measured lengths and limits of agreement were narrow. The enhanced ability offered by micro-CT to phenotype the murine penis has the potential to improve translational studies examining the molecular pathways contributing to anomalous penile development. The present study describes the first reported use of micro-CT with iodine staining for imaging the murine penis. Producing repeated histologic sections of identical orientation was limited by inherent imperfections in mounting and tissue sectioning, but this was compensated for by using micro-CT reconstructions to identify matching virtual sections. This study demonstrates the successful use of micro-CT with iodine staining, which has the potential for submicron spatial resolution, as a non-destructive method of characterizing murine penile morphology. O'Neill M, Huang GO, Lamb DJ. Novel Application of Micro-Computerized Tomography for Morphologic Characterization of the Murine Penis. J Sex Med 2017;14:1533-1539. Copyright © 2017. Published by Elsevier Inc.
Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...
Kamogawa, Junji; Kato, Osamu; Morizane, Tatsunori; Hato, Taizo
2015-01-01
There have been several imaging studies of cervical radiculopathy, but no three-dimensional (3D) images have shown the path, position, and pathological changes of the cervical nerve roots and spinal root ganglion relative to the cervical bony structure. The objective of this study was to introduce a technique that enables the virtual pathology of the nerve root to be assessed using 3D magnetic resonance (MR)/computed tomography (CT) fusion images that show the compression of the proximal portion of the cervical nerve root by both the herniated disc and the preforaminal or foraminal bony spur in patients with cervical radiculopathy. MR and CT images were obtained from three patients with cervical radiculopathy. 3D MR images were placed onto 3D CT images using a computer workstation. The entire nerve root could be visualized in 3D with or without the vertebrae. The most important characteristic evident on the images was flattening of the nerve root by a bony spur. The affected root was constricted at a pre-ganglion site. In cases of severe deformity, the flattened portion of the root seemed to change the angle of its path, resulting in twisted condition. The 3D MR/CT fusion imaging technique enhances visualization of pathoanatomy in cervical hidden area that is composed of the root and intervertebral foramen. This technique provides two distinct advantages for diagnosis of cervical radiculopathy. First, the isolation of individual vertebra clarifies the deformities of the whole root groove, including both the uncinate process and superior articular process in the cervical spine. Second, the tortuous or twisted condition of a compressed root can be visualized. The surgeon can identify the narrowest face of the root if they view the MR/CT fusion image from the posterolateral-inferior direction. Surgeons use MR/CT fusion images as a pre-operative map and for intraoperative navigation. The MR/CT fusion images can also be used as educational materials for all hospital staff and for patients and patients' families who provide informed consent for treatments.
Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M
2013-07-01
Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt.
Shokouhi, Bahman N; Khan, Mohammad; Carter, Martyn J; Khan, Nasser Q; Mills, Philip; Morris, Danielle; Rowlands, David E; Samsheer, Kote; Sargeant, Ian R; McIntyre, Peter B; Greenfield, Simon M
2013-01-01
Objective Acute upper gastrointestinal bleeding (AUGIB) results in 25 000 hospital admissions annually. Patients admitted at weekends with AUGIB have increased mortality, and guidelines advise out-of-hours endoscopy. We present retrospective data from our service involving the interhospital transfer of patients. Design We pooled resources of two neighbouring general hospitals, just north of London. Emergency endoscopy is performed at the start of the list followed by elective endoscopy in the endoscopy unit on Saturday and Sunday mornings. From Friday evening to Sunday morning, patients admitted to Queen Elizabeth II Hospital (QEII) are medically stabilised and transferred to Lister Hospital by ambulance. Results 240 endoscopies were performed out of hours from December 2007 to March 2011. Of these, 54 patients were transferred: nine had emergency endoscopy at QEII as they were medically unstable; eight of the patients transferred required therapeutic intervention for active bleeding. The mean pre-endoscopy Rockall score of those transferred was 2.5. We examined the records of 51 of the 54 patients transferred. There were three deaths within 30 days after endoscopy not associated with the transfer process. 19 (37%) patients had reduced hospitalisation after having their endoscopy at the weekend. Conclusions The introduction of the out-of-hours endoscopy service in our trust has had multiple benefits, including patients consistently receiving timely emergency endoscopy, significantly reduced disruption to emergency operating theatres, and participation of endoscopy nurses ensures a better and safer experience for patients, and better endoscopy decontamination. We suggest our model is safe and feasible for other small units wishing to set up their own out-of-hours endoscopy service to adopt. PMID:28839729
Djukic, Tijana; Mandic, Vesna; Filipovic, Nenad
2013-12-01
Medical education, training and preoperative diagnostics can be drastically improved with advanced technologies, such as virtual reality. The method proposed in this paper enables medical doctors and students to visualize and manipulate three-dimensional models created from CT or MRI scans, and also to analyze the results of fluid flow simulations. Simulation of fluid flow using the finite element method is performed, in order to compute the shear stress on the artery walls. The simulation of motion through the artery is also enabled. The virtual reality system proposed here could shorten the length of training programs and make the education process more effective. © 2013 Published by Elsevier Ltd.
Day, Lukejohn W; Belson, David; Dessouky, Maged; Hawkins, Caitlin; Hogan, Michael
2014-11-01
Improvements in endoscopy center efficiency are needed, but scant data are available. To identify opportunities to improve patient throughput while balancing resource use and patient wait times in a safety-net endoscopy center. Safety-net endoscopy center. Outpatients undergoing endoscopy. A time and motion study was performed and a discrete event simulation model constructed to evaluate multiple scenarios aimed at improving endoscopy center efficiency. Procedure volume and patient wait time. Data were collected on 278 patients. Time and motion study revealed that 53.8 procedures were performed per week, with patients spending 2.3 hours at the endoscopy center. By using discrete event simulation modeling, a number of proposed changes to the endoscopy center were assessed. Decreasing scheduled endoscopy appointment times from 60 to 45 minutes led to a 26.4% increase in the number of procedures performed per week, but also increased patient wait time. Increasing the number of endoscopists by 1 each half day resulted in increased procedure volume, but there was a concomitant increase in patient wait time and nurse utilization exceeding capacity. By combining several proposed scenarios together in the simulation model, the greatest improvement in performance metrics was created by moving patient endoscopy appointments from the afternoon to the morning. In this simulation at 45- and 40-minute appointment times, procedure volume increased by 30.5% and 52.0% and patient time spent in the endoscopy center decreased by 17.4% and 13.0%, respectively. The predictions of the simulation model were found to be accurate when compared with actual changes implemented in the endoscopy center. Findings may not be generalizable to non-safety-net endoscopy centers. The combination of minor, cost-effective changes such as reducing appointment times, minimizing and standardizing recovery time, and making small increases in preprocedure ancillary staff maximized endoscopy center efficiency across a number of performance metrics. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ciunel, St.; Tica, B.
2016-08-01
The paper presents the studies made on a similar biomechanical system composed by neck, head and thorax bones. The models were defined in a CAD environment which includes Adams algorithm for dynamic simulations. The virtual models and the entire morphology were obtained starting with CT images made on a living human subject. The main movements analyzed were: axial rotation (left-right), lateral bending (left-right) and flexion- extension movement. After simulation was obtained the entire biomechanical behavior based on data tables or diagrams. That virtual model composed by neck and head can be included in complex system (as a car system) and supposed to several impact simulations (virtual crash tests). Also, our research team built main components of a testing device for dummy car crash neck-head system using anatomical data.
Reagan, Adrian C; Mallinson, Paul I; O'Connell, Timothy; McLaughlin, Patrick D; Krauss, Bernhard; Munk, Peter L; Nicolaou, Savvas; Ouellette, Hugue A
2014-01-01
Computed tomography (CT) is often used to assess the presence of occult fractures when plain radiographs are equivocal in the acute traumatic setting. While providing increased spatial resolution, conventional computed tomography is limited in the assessment of bone marrow edema, a finding that is readily detectable on magnetic resonance imaging (MRI).Dual-energy CT has recently been shown to demonstrate patterns of bone marrow edema similar to corresponding MRI studies. Dual-energy CT may therefore provide a convenient modality for further characterizing acute bony injury when MRI is not readily available. We report our initial experiences of 4 cases with imaging and clinical correlation.
NASA Astrophysics Data System (ADS)
Lam, Walter Y. H.; Ngan, Henry Y. T.; Wat, Peter Y. P.; Luk, Henry W. K.; Goto, Tazuko K.; Pow, Edmond H. N.
2015-02-01
Medical radiography is the use of radiation to "see through" a human body without breaching its integrity (surface). With computed tomography (CT)/cone beam computed tomography (CBCT), three-dimensional (3D) imaging can be produced. These imagings not only facilitate disease diagnosis but also enable computer-aided surgical planning/navigation. In dentistry, the common method for transfer of the virtual surgical planning to the patient (reality) is the use of surgical stent either with a preloaded planning (static) like a channel or a real time surgical navigation (dynamic) after registration with fiducial markers (RF). This paper describes using the corner of a cube as a radiopaque fiducial marker on an acrylic (plastic) stent, this RF allows robust calibration and registration of Cartesian (x, y, z)- coordinates for linking up the patient (reality) and the imaging (virtuality) and hence the surgical planning can be transferred in either static or dynamic way. The accuracy of computer-aided implant surgery was measured with reference to coordinates. In our preliminary model surgery, a dental implant was planned virtually and placed with preloaded surgical guide. The deviation of the placed implant apex from the planning was x=+0.56mm [more right], y=- 0.05mm [deeper], z=-0.26mm [more lingual]) which was within clinically 2mm safety range. For comparison with the virtual planning, the physically placed implant was CT/CBCT scanned and errors may be introduced. The difference of the actual implant apex to the virtual apex was x=0.00mm, y=+0.21mm [shallower], z=-1.35mm [more lingual] and this should be brought in mind when interpret the results.
Anil, S M; Kato, Y; Hayakawa, M; Yoshida, K; Nagahisha, S; Kanno, T
2007-04-01
Advances in computer imaging and technology have facilitated enhancement in surgical planning with a 3-dimensional model of the surgical plan of action utilizing advanced visualization tools in order to plan individual interactive operations with the aid of the dextroscope. This provides a proper 3-dimensional imaging insight to the pathological anatomy and sets a new dimension in collaboration for training and education. The case of a seventeen-year-old female, being operated with the aid of a preoperative 3-dimensional virtual reality planning and the practical application of the neurosurgical operation, is presented. This young lady presented with a two-year history of recurrent episodes of severe, global, throbbing headache with episodes of projectile vomiting associated with shoulder pain which progressively worsened. She had no obvious neurological deficits on clinical examination. CT and MRI showed a contrast-enhancing midline posterior fossa space-occupying lesion. Utilizing virtual imaging technology with the aid of a dextroscope which generates stereoscopic images, a 3-dimensional image was produced with the CT and MRI images. A preoperative planning for excision of the lesion was made and a real-time 3-dimensional volume was produced and surgical planning with the dextroscope was made and the lesion excised. Virtual reality has brought new proportions in 3-dimensional planning and management of various complex neuroanatomical problems that are faced during various operations. Integration of 3-dimensional imaging with stereoscopic vision makes understanding the complex anatomy easier and helps improve decision making in patient management.
Bowel obstruction complicated by ischemia: analysis of CT findings.
Cox, Veronica L; Tahvildari, Ali M; Johnson, Benjamin; Wei, Wei; Jeffrey, R Brooke
2018-06-01
To analyze CT signs of bowel ischemia in patients with surgical bowel obstruction, and thereby improve CT diagnosis in this common clinical scenario. Surgical and histopathological findings were used as the reference standard. We retrospectively analyzed CT findings in patients brought to surgery for bowel obstruction over 13 years. Etiology of obstruction (adhesion, hernia, etc.) was recorded. Specific CT features of acute mesenteric ischemia (AMI) were analyzed, including bowel wall thickening, mucosal hypoenhancement, and others. 173 cases were eligible for analysis. 21% of cases were positive for bowel ischemia. Volvulus, internal hernia, and closed-loop obstructions showed ischemia rates of 60%, 43%, and 43%; ischemia rate in obstruction from simple adhesion was 21%. Patients with bowel obstruction related to malignancy were never ischemic. Sensitivities and specificities for CT features predicting ischemia were calculated, with wall thickening, hypoenhancement, and pneumatosis showing high specificity for ischemia (86%-100%). Wall thickening, hypoenhancement, and pneumatosis are highly specific CT signs of ischemia in the setting of obstruction. None of the evaluated CT signs were found to be highly sensitive. Overall frequency of ischemia in surgical bowel obstruction is 21%, and 2-3 times that for complex obstructions (volvulus, closed loop, etc.). Obstructions related to malignancy virtually never become ischemic.
Endoscopy: MedlinePlus Health Topic
... What Is Endoscopy? (American Cancer Society) Also in Spanish Related Issues Ensuring the Safety of Your Endoscopic Procedure (American Society for Gastrointestinal Endoscopy) Also in Spanish Sedation for Your Endoscopy (American College of Gastroenterology) ...
Less Is More: A Minimalist Approach to Endoscopy.
Shaheen, Nicholas J; Fennerty, M Brian; Bergman, Jacques J
2018-05-01
A substantial literature documents inappropriate usage of gastrointestinal endoscopy in a variety of clinical settings. Overusage of endoscopy appears to be common, and 30% or more of procedures performed in some clinical settings have questionable indications. The potential reasons for overuse of endoscopy are multiple, and include cancer phobia, fear of medical malpractice litigation, profit motive, the investigation of "incidentalomas" found on other imaging, and underappreciation of the delayed harms of endoscopy, among other reasons. Clinical guidelines, which should limit overuse of endoscopy, may instead serve to promote it, if authors opt to be "conservative," recommending endoscopy in situations of unclear utility. Several strategies may decrease overuse of endoscopy, including careful attention to risk stratification when choosing patients to screen, adherence to guidelines for surveillance intervals for colonoscopy, the use of quality indicators to identify outliers in endoscopy utilization, and education on appropriate indications and the risks of overuse at the medical student, residency, and fellowship levels. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo
2014-04-01
To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.
Endoscopic palliation of advanced esophageal cancer
Mocanu, A; Bârla, R; Hoara, P; Constantinoiu, S
2015-01-01
Esophageal cancer represents one of the most aggressive digestive tumors, with a survival rate at 5 years of only 10%. Globally, during the last three decades, there has been an increasing incidence of the esophageal cancer, approx. 400,000 new esophageal cancers being currently diagnosed annually. This represents the eighth leading cause of cancer incidence and the sixth leading cause of cancer death overall. Taking into account the population’s global aging and thus, the increase in the number of patients who will not bear surgery, PCT and radiation, or the fact that they do not want it especially because of deficiencies and associated pathology, the endoscopic ablative techniques with palliation purposes represent the alternative. If we refer to the Western Europe countries and North America, we notice an increase of esophageal adenocarcinoma rate versus squamous cancer. As for the Asian region, referring in particular to China and Japan, 9 out of 10 esophageal cancers are squamous cell carcinomas. For at least half of the patients with EC (esophageal cancer) there is no hope of healing because of the advanced regional malignant invasion (T3-4, N+, M+) with no chemo and radiotherapy response, poor preoperative patients’ conditions or systemic metastasis. The low life expectancy does not justify the risky medical procedures, the goal of the therapy consisting in the improvement of the quality of life by eliminating dysphagia (reestablishing oral feeding) which represents the most common complication of EC, the respiratory tract complication caused by eso-tracheal fistulas or by eliminating chest pain. To treat dysphagia, which is the main target of palliation, combined methods like endoscopic, chemo and radio-therapy, can be used, each one with indications, benefits and risks. Abbreviations: SEPS = self expanding plastic stent, SREMS = self expanding metal stent, EBRT = Endoscopic brachy radiotherapy, EUS = Ultra sound endoscopy, CT = Computer tomograph, UGE = Upper gastro endoscopy, PET-CT = Positron Emission Tomography, APC = argon plasma coagulation, PDT = photo dynamic therapy, PCT = Poli-chemotherapy, RT = Radio-therapy PMID:25866578
Masselli, Gabriele; Mastroiacovo, Ilaria; De Marco, Emidio; Francione, Giulia; Casciani, Emanuele; Polettini, Elisabetta; Gualdi, Gianfranco
2016-01-01
Crohn’s disease affects more than 500000 individuals in the United States, and about 25% of cases are diagnosed during the pediatric period. Imaging of the bowel has undergone dramatic changes in the past two decades. The endoscopy with biopsy is generally considered the diagnostic reference standard, this combination can evaluates only the mucosa, not inflammation or fibrosis in the mucosa. Actually, the only modalities that can visualize submucosal tissues throughout the small bowel are the computed tomography (CT) enterography (CTE) with the magnetic resonance enterography (MRE). CT generally is highly utilized, but there is growing concern over ionizing radiation and cancer risk; it is a very important aspect to keep in consideration in pediatric patients. In contrast to CTE, MRE does not subject patients to ionizing radiation and can be used to detect detailed morphologic information and functional data of bowel disease, to monitor the effects of medical therapy more accurately, to detect residual active disease even in patients showing apparent clinical resolution and to guide treatment more accurately. PMID:27551337
Pediatric Small Bowel Crohn Disease: Correlation of US and MR Enterography
Smith, Ethan A.; Sanchez, Ramon J.; DiPietro, Michael A.; DeMatos-Maillard, Vera; Strouse, Peter J.; Darge, Kassa
2015-01-01
Small bowel Crohn disease is commonly diagnosed during the pediatric period, and recent investigations show that its incidence is increasing in this age group. Diagnosis and follow-up of this condition are commonly based on a combination of patient history and physical examination, disease activity surveys, laboratory assessment, and endoscopy with biopsy, but imaging also plays a central role. Ultrasonography (US) is an underutilized well-tolerated imaging modality for screening and follow-up of small bowel Crohn disease in children and adolescents. US has numerous advantages over computed tomographic (CT) enterography and magnetic resonance (MR) enterography, including low cost and no required use of oral or intravenous contrast material. US also has the potential to provide images with higher spatial resolution than those obtained at CT enterography and MR enterography, allows faster examination than does MR enterography, does not involve ionizing radiation, and does not require sedation or general anesthesia. US accurately depicts small bowel and mesenteric changes related to pediatric Crohn disease, and US findings show a high correlation with MR imaging findings in this patient population. ©RSNA, 2015 PMID:25839736
Thyroid gland rupture caused by blunt trauma to the neck.
Hara, Hirotaka; Hirose, Yoshinobu; Yamashita, Hiroshi
2016-02-19
Thyroid rupture following blunt trauma is extremely rare, and neck pain without swelling may be the only presenting symptom. However, hemorrhage and hematoma subsequently causes severe tracheal compression and respiratory distress. A 71-year-old Japanese woman visited our emergency room with a complaint of increasing right-sided neck pain at the thyroid cartilage level after she tripped and accidentally hit her neck against a pole 3 h back. On admission, her vital signs were stable. There was no swelling or subcutaneous emphysema. Laryngeal endoscopy revealed mild laryngeal edema, although there was no impairment in vocal fold mobility on either side. Contrast-enhanced computed tomography (CT) revealed rupture of the right lobe of the thyroid gland accompanied by a large hematoma extending from the neck to the mediastinum. Under general anesthesia, the right lobe was resected and the hematoma was evacuated. Only a few isolated cases of thyroid rupture caused by blunt neck trauma have been reported in patients with normal thyroid glands and neck pain without swelling may be the only presenting symptom. When suspected, CT should be performed to confirm the diagnosis determine the optimal treatment.
Handzel, Ophir; Wang, Haobing; Fiering, Jason; Borenstein, Jeffrey T.; Mescher, Mark J.; Leary Swan, Erin E.; Murphy, Brian A.; Chen, Zhiqiang; Peppi, Marcello; Sewell, William F.; Kujawa, Sharon G.; McKenna, Michael J.
2009-01-01
Temporal bone implants can be used to electrically stimulate the auditory nerve, to amplify sound, to deliver drugs to the inner ear and potentially for other future applications. The implants require storage space and access to the middle or inner ears. The most acceptable space is the cavity created by a canal wall up mastoidectomy. Detailed knowledge of the available space for implantation and pathways to access the middle and inner ears is necessary for the design of implants and successful implantation. Based on temporal bone CT scans a method for three-dimensional reconstruction of a virtual canal wall up mastoidectomy space is described. Using Amira® software the area to be removed during such surgery is marked on axial CT slices, and a three-dimensional model of that space is created. The average volume of 31 reconstructed models is 12.6 cm3 with standard deviation of 3.69 cm3, ranging from 7.97 to 23.25 cm3. Critical distances were measured directly from the model and their averages were calculated: height 3.69 cm, depth 2.43 cm, length above the external auditory canal (EAC) 4.45 cm and length posterior to EAC 3.16 cm. These linear measurements did not correlate well with volume measurements. The shape of the models was variable to a significant extent making the prediction of successful implantation for a given design based on linear and volumetric measurement unreliable. Hence, to assure successful implantation, preoperative assessment should include a virtual fitting of an implant into the intended storage space. The above-mentioned three-dimensional models were exported from Amira to a Solidworks application where virtual fitting was performed. Our results are compared to other temporal bone implant virtual fitting studies. Virtual fitting has been suggested for other human applications. PMID:19372649
Navigation system for robot-assisted intra-articular lower-limb fracture surgery.
Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja
2016-10-01
In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.
Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R
2010-05-01
Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.
The effect of upper gastrointestinal system endoscopy process on serum oxidative stress levels.
Turan, Mehmet Nuri; Aslan, Mehmet; Bolukbas, Filiz Fusun; Bolukbas, Cengiz; Selek, Sahbettin; Sabuncu, Tevfik
2016-12-01
Some authors have investigated the effects of oxidative stress in some process such as undergoing laparoscopic. However, the effect of upper gastrointestinal system endoscopy process on oxidative stress is unclear. We evaluated the short-term effect of upper gastrointestinal system endoscopy process on oxidative stress. Thirty patients who underwent endoscopy process and 20 healthy controls were enrolled in the prospective study. Serum total antioxidant capacity and total oxidant status measurements were measured before and after endoscopy process. The ratio percentage of total oxidant status to total antioxidant capacity was regarded as oxidative stress index. Before endoscopy process, serum total antioxidant capacity levels were higher, while serum total oxidant status levels and oxidative stress index values were lower in patients than controls, but this difference was not statistically significant (all, p > 0.05). After endoscopy process, serum total antioxidant capacity and total oxidant status levels were significantly higher in patients than before endoscopy process (both, p < 0.05). However, oxidative stress index values were slight higher in patients but this difference was not statistically significant (p > 0.05). We observed that serum TAC and TOS levels were increased in patients who underwent endoscopy process after endoscopy process. However, short-time upper gastrointestinal system endoscopy process did not cause an important change in the oxidative stress index. Further studies enrolling a larger number of patients are required to clarify the results obtained here.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V
2012-08-01
At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2013-01-01
Presently, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures which provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high resolution images, it is also safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically-specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically-relevant depths, ideal for soft tissue imaging. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, enabling multi-modality imaging with complementary contrast. Here, we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and demonstrate its ability to image internal organs in vivo, illustrating its potential clinical application. PMID:22797808
NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.
Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando
2016-12-01
Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.
Efficiency of upper gastrointestinal endoscopy in pediatric surgical practice
Temiz, Abdulkerim
2015-01-01
After the introduction of flexible fiber optic endoscopy to pediatric gastroenterology in the 1970s, upper gastrointestinal (UGI) endoscopy can be performed for the diagnosis and treatment of all age groups of children. We review indications, contraindications, preparation of patients for the procedure, and details of diagnostic and therapeutic UGI endoscopy used in pediatric surgery. We also discuss potential complications of endoscopy. PMID:26566483
Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya
2016-04-01
Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.
Borojeni, Azadeh A.T.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.; Garcia, Guilherme J. M.
2016-01-01
Virtual surgery planning based on computational fluid dynamics (CFD) simulations has the potential to improve surgical outcomes for nasal airway obstruction (NAO) patients, but the benefits of virtual surgery planning must outweigh the risks of radiation exposure. Cone beam computed tomography (CBCT) scans represent an attractive imaging modality for virtual surgery planning due to lower costs and lower radiation exposures compared with conventional CT scans. However, to minimize the radiation exposure, the CBCT sinusitis protocol sometimes images only the nasal cavity, excluding the nasopharynx. The goal of this study was to develop an idealized nasopharynx geometry for accurate representation of outlet boundary conditions when the nasopharynx geometry is unavailable. Anatomically-accurate models of the nasopharynx created from thirty CT scans were intersected with planes rotated at different angles to obtain an average geometry. Cross sections of the idealized nasopharynx were approximated as ellipses with cross-sectional areas and aspect ratios equal to the average in the actual patient-specific models. CFD simulations were performed to investigate whether nasal airflow patterns were affected when the CT-based nasopharynx was replaced by the idealized nasopharynx in 10 NAO patients. Despite the simple form of the idealized geometry, all biophysical variables (nasal resistance, airflow rate, and heat fluxes) were very similar in the idealized vs. patient-specific models. The results confirmed the expectation that the nasopharynx geometry has a minimal effect in the nasal airflow patterns during inspiration. The idealized nasopharynx geometry will be useful in future CFD studies of nasal airflow based on medical images that exclude the nasopharynx. PMID:27525807
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, Hyunuk; Kum, Oyeon; Han, Youngyih, E-mail: youngyih@skku.edu
Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT imagemore » of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.« less
Qiu, L L; Li, S; Bai, Y X
2016-06-01
To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.
Parchi, Paolo Domenico; Ferrari, Vincenzo; Piolanti, Nicola; Andreani, Lorenzo; Condino, Sara; Evangelisti, Gisberto; Lisanti, Michele
2013-09-01
Each year approximately 1 million total hip replacements (THR) are performed worldwide. A percentage of failure due to surgical approach and imprecise implant placement still exists. These result in several serious complications. We propose an approach to plan, to simulate, and to assist prosthesis implantation for difficult cases of THR based on 3-D virtual models, generated by segmenting patients' CT images, 3-D solid models, obtained by rapid prototyping (RP), and virtual procedure simulation. We carried out 8 THR with the aid of 3-D reconstruction and RP. After each procedure a questionnaire was submitted to the surgeon to assess the perceived added value of the technology. In all cases, the surgeon evaluated the 3-D model as useful in order to perform the planning. The clinical results showed a mean increase in the Harris Hip Score of about 42.5 points. The mean time of prototyping was 7.3 hours, (min 3.5 hours, max 9.3 hours). The mean surgery time was 65 minutes (min 50 minutes, max 88 minutes). Our study suggests that meticulous preoperative planning is necessary in front of a great aberration of the joint and in absence of normal anatomical landmarks, CT scan is mandatory, and 3-D reconstruction with solid model is useful.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faby, Sebastian, E-mail: sebastian.faby@dkfz.de; Kuchenbecker, Stefan; Sawall, Stefan
2015-07-15
Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models andmore » x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.« less
Non-squamous cell neoplasms of the larynx: radiologic-pathologic correlation.
Becker, M; Moulin, G; Kurt, A M; Dulgerov, P; Vukanovic, S; Zbären, P; Marchal, F; Rüfenacht, D A; Terrier, F
1998-01-01
A variety of benign and malignant non-squamous cell neoplasms may affect the larynx. Most of these uncommon laryngeal neoplasms are located beneath an intact mucosa, making diagnosis difficult with endoscopy alone, and sampling errors may occur if only traditional superficial biopsies are performed. In some laryngeal neoplasms, radiologic evaluation allows the correct diagnosis. Hemangiomas have very high signal intensity at T2-weighted magnetic resonance (MR) imaging and strong enhancement at both computed tomography (CT) and MR imaging after administration of contrast material. Phleboliths, which are pathognomonic for hemangiomas, are easily identified at CT. Chondrogenic tumors typically manifest with coarse or stippled calcifications at CT. Because of their high water content, chondrogenic tumors have very high signal intensity on T2-weighted MR images, whereas only moderate enhancement is observed after administration of contrast material. Lipomas typically manifest at both CT and MR imaging as homogeneous nonenhancing lesions. They are isoattenuating to subcutaneous fat at CT and isointense relative to subcutaneous fat with all MR pulse sequences. Metastases from renal adenocarcinoma typically demonstrate strong contrast enhancement and flow voids at MR imaging, and metastases from melanotic melanoma usually have high signal intensity on T1-weighted MR images and low signal intensity on T2-weighted images owing to the paramagnetic properties of melanin. Although radiologic findings are nonspecific in most other non-squamous cell neoplasms of the larynx (eg, Kaposi sarcoma, hematopoietic tumors, tumors of the minor salivary glands, metastases from amelanotic melanoma), cross-sectional imaging can play an important role in the diagnostic work-up of these unusual tumors by delineating the extent of submucosal tumor spread and directing the endoscopist to the appropriate site for the deep, transmucosal biopsies needed to establish the diagnosis. In addition, CT and MR imaging are crucial for posttherapeutic monitoring and early detection of local recurrence.
Sánchez, Joaquín; Medina, Gerardo; Buhse, Thomas; Holmgren, Jan; Soberón-Chavez, Gloria
2004-03-01
The regulatory systems controlling expression of the ctxAB genes encoding cholera toxin (CT) in the classical and El Tor biotypes of pathogenic Vibrio cholerae have been characterized and found to be almost identical. Notwithstanding this, special in vitro conditions, called AKI conditions, are required for El Tor bacteria to produce CT. The AKI conditions involve biphasic cultures. In phase 1 the organism is grown in a still tube for 4 h. In phase 2 the medium is poured into a flask to continue growth with shaking. Virtually no expression of CT occurs if this protocol is not followed. Here we demonstrated that CT expression takes place in single-phase still cultures if the volume-to-surface-area ratio is decreased, both under air and under an inert atmosphere. The expression of key genes involved in the regulation of CT production was analyzed, and we found that the expression pattern closely resembles the in vivo expression pattern.
Enciso, R; Memon, A; Mah, J
2003-01-01
The research goal at the Craniofacial Virtual Reality Laboratory of the School of Dentistry in conjunction with the Integrated Media Systems Center, School of Engineering, University of Southern California, is to develop computer methods to accurately visualize patients in three dimensions using advanced imaging and data acquisition devices such as cone-beam computerized tomography (CT) and mandibular motion capture. Data from these devices were integrated for three-dimensional (3D) patient-specific visualization, modeling and animation. Generic methods are in development that can be used with common CT image format (DICOM), mesh format (STL) and motion data (3D position over time). This paper presents preliminary descriptive studies on: 1) segmentation of the lower and upper jaws with two types of CT data--(a) traditional whole head CT data and (b) the new dental Newtom CT; 2) manual integration of accurate 3D tooth crowns with the segmented lower jaw 3D model; 3) realistic patient-specific 3D animation of the lower jaw.
Chen, Jian; Smith, Andrew D; Khan, Majid A; Sinning, Allan R; Conway, Marianne L; Cui, Dongmei
2017-11-01
Recent improvements in three-dimensional (3D) virtual modeling software allows anatomists to generate high-resolution, visually appealing, colored, anatomical 3D models from computed tomography (CT) images. In this study, high-resolution CT images of a cadaver were used to develop clinically relevant anatomic models including facial skull, nasal cavity, septum, turbinates, paranasal sinuses, optic nerve, pituitary gland, carotid artery, cervical vertebrae, atlanto-axial joint, cervical spinal cord, cervical nerve root, and vertebral artery that can be used to teach clinical trainees (students, residents, and fellows) approaches for trans-sphenoidal pituitary surgery and cervical spine injection procedure. Volume, surface rendering and a new rendering technique, semi-auto-combined, were applied in the study. These models enable visualization, manipulation, and interaction on a computer and can be presented in a stereoscopic 3D virtual environment, which makes users feel as if they are inside the model. Anat Sci Educ 10: 598-606. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.
Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois
2017-01-01
The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.
Yang, Hyo-Joon; Lim, Seon Hee; Lee, Changhyun; Choi, Ji Min; Yang, Jong In; Chung, Su Jin; Choi, Seung Ho; Im, Jong Pil; Kim, Sang Gyun; Kim, Joo Sung
2016-07-01
It is often difficult to differentiate gastric mucosa-associated lymphoid tissue (MALT) lymphoma from Helicobacter pylori-associated follicular gastritis, and thus, it becomes unclear how to manage these diseases. This study aimed to explore the management strategy for and the long-term outcomes of suspicious gastric MALT lymphoma detected by forceps biopsy during screening upper endoscopy. Between October 2003 and May 2013, consecutive subjects who were diagnosed with suspicious gastric MALT lymphomas by screening endoscopy in a health checkup program in Korea were retrospectively enrolled. Suspicious MALT lymphoma was defined as a Wotherspoon score of 3 or 4 upon pathological evaluation of the biopsy specimen. Of 105,164 subjects who underwent screening endoscopies, 49 patients with suspicious MALT lymphomas who underwent subsequent endoscopy were enrolled. Eight patients received a subsequent endoscopy without H. pylori eradication (subsequent endoscopy only group), and 41 patients received H. pylori eradication first followed by endoscopy (eradication first group). MALT lymphoma development was significantly lower in the eradication first group (2/41, 4.9%) than in the subsequent endoscopy only group (3/8, 37.5%, P = 0.026). Notably, among 35 patients with successful H. pylori eradication, there was only one MALT lymphoma patient (2.9%) in whom complete remission was achieved, and there was no recurrence during a median 45 months of endoscopic follow-up. H. pylori eradication with subsequent endoscopy would be a practical management option for suspicious MALT lymphoma detected in a forceps biopsy specimen obtained during screening upper endoscopy.
Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?
Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires
2018-01-01
To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.
[Unusually large stromal tumor of the rectum causing obstruction].
Hornok, L; Lestár, B; Nagy, P; Ritter, L; László, S; Kiss, J
2000-06-01
A male, 74 years old patient with perineal, sacral pain and with defecation disorders attended the outpatient clinic of HIETE. The origine of the complains was a retrorectal, fist like, rectum narrowing tumor. The tumor was covered by normal mucosa from rectal side. Preoperative examinations--endoscopy, CT, MRI transrectal US--detected a tumor with size 7 x 6 x 5 cm, growing from the muscular wall of the rectum, with no connection with the surrounding tissues. Deep biopsy revealed malignant mesenchymal tumor. After preoperative irradiation abdominoperineal rectum amputation was performed. The recovery was uneventful. The definitive hystological examination proved a gastrointestinal stromal tumor (GIST). This type of tumor rarely occurs in the large intestine or in the rectum, that why the publishing can be interesting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, X; Arbique, G; Guild, J
Purpose: To evaluate the quantitative image quality of spectral reconstructions of phantom data from a spectral CT scanner. Methods: The spectral CT scanner (IQon Spectral CT, Philips Healthcare) is equipped with a dual-layer detector and generates conventional 80-140 kVp images and variety of spectral reconstructions, e.g., virtual monochromatic (VM) images, virtual non-contrast (VNC) images, iodine maps, and effective atomic number (Z) images. A cylindrical solid water phantom (Gammex 472, 33 cm diameter and 5 cm thick) with iodine (2.0-20.0 mg I/ml) and calcium (50-600 mg/ml) rod inserts was scanned at 120 kVp and 27 mGy CTDIvol. Spectral reconstructions were evaluatedmore » by comparing image measurements with theoretical values calculated from nominal rod compositions provided by the phantom manufacturer. The theoretical VNC was calculated using water and iodine basis material decomposition, and the theoretical Z was calculated using two common methods, the chemical formula method (Z1) and the dual-energy ratio method (Z2). Results: Beam-hardening-like artifacts between high-attenuation calcium rods (≥300 mg/ml, >800 HU) influenced quantitative measurements, so the quantitative analysis was only performed on iodine rods using the images from the scan with all the calcium rods removed. The CT numbers of the iodine rods in the VM images (50∼150 keV) were close to theoretical values with average difference of 2.4±6.9 HU. Compared with theoretical values, the average difference for iodine concentration, VNC CT number and effective Z of iodine rods were −0.10±0.38 mg/ml, −0.1±8.2 HU, 0.25±0.06 (Z1) and −0.23±0.07 (Z2). Conclusion: The results indicate that the spectral CT scanner generates quantitatively accurate spectral reconstructions at clinically relevant iodine concentrations. Beam-hardening-like artifacts still exist when high-attenuation objects are present and their impact on patient images needs further investigation. YY is an employee of Philips Healthcare.« less
Endoscopy in Canada: Proceedings of the National Roundtable
Switzer, Noah; Dixon, Elijah; Tinmouth, Jill; Bradley, Nori; Vassiliou, Melina; Schwaitzberg, Steve; Gomes, Anthony; Ellsmere, James; de Gara, Chris
2015-01-01
This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists. PMID:25886520
The virtual craniofacial patient: 3D jaw modeling and animation.
Enciso, Reyes; Memon, Ahmed; Fidaleo, Douglas A; Neumann, Ulrich; Mah, James
2003-01-01
In this paper, we present new developments in the area of 3D human jaw modeling and animation. CT (Computed Tomography) scans have traditionally been used to evaluate patients with dental implants, assess tumors, cysts, fractures and surgical procedures. More recently this data has been utilized to generate models. Researchers have reported semi-automatic techniques to segment and model the human jaw from CT images and manually segment the jaw from MRI images. Recently opto-electronic and ultrasonic-based systems (JMA from Zebris) have been developed to record mandibular position and movement. In this research project we introduce: (1) automatic patient-specific three-dimensional jaw modeling from CT data and (2) three-dimensional jaw motion simulation using jaw tracking data from the JMA system (Zebris).
Near-infrared dental imaging using scanning fiber endoscope
NASA Astrophysics Data System (ADS)
Zhou, Yaxuan; Lee, Robert; Sadr, Alireza; Seibel, Eric J.
2018-02-01
Near-infrared (NIR) wavelength range of 1300-1500nm has the potential to outperform or augment other dental imaging modalities such as fluorescence imaging, owing to its lower scattering coefficient in enamel and trans- parency on stains and non-cariogenic plaque. However, cameras in this wavelength range are bulky and expensive, which lead to difficulties for in-vivo use and commercialization. Thus, we have proposed a new imaging device combining the scanning fiber endoscopy (SFE) and NIR imaging technology. The NIR SFE system has the advantage of miniature size (1.6 mm), flexible shaft, video frame rate (7Hz) and expandable wide field-of-view (60 degrees). Eleven extracted human teeth with or without occlusal caries were scanned by micro-computed X-ray tomography (micro-CT) to obtain 3D micro-CT images, which serve as the standard for comparison. NIR images in reflection mode were then taken on all the occlusal surfaces, using 1310nm super luminescent diode and 1460nm laser diode respectively. Qualitative comparison was performed between near-infrared im- ages and micro-CT images. Enamel demineralization in NIR appeared as areas of increased reflectivity, and distinguished from non-carious staining at the base of occlusal fissures or developmental defects on cusps. This preliminary work presented proof for practicability of combining NIR imaging technology with SFE for reliable and noninvasive dental imaging with miniaturization and low cost.
Nephrocalcinosis: re-defined in the era of endourology
Miller, Nicole L.; Humphreys, Mitchell R.; Coe, Fredric L.; Evan, Andrew P.; Bledsoe, Sharon B.; Handa, Shelly E.; Lingeman, James E.
2013-01-01
Nephrocalcinosis generally refers to the presence of calcium salts within renal tissue, but this term is also used radiologically in diagnostic imaging in disease states that also produce renal stones, so that it is not always clear whether it is tissue calcifications or urinary calculi that give rise to the characteristic appearance of the kidney on x-ray or computed tomography (CT). Recent advances in endoscopic imaging now allow the visual distinction between stones and papillary nephrocalcinosis, and intrarenal endoscopy can also verify the complete removal of urinary stones, so that subsequent radiographic appearance can be confidently attributed to nephrocalcinosis. This report shows exemplary cases of primary hyperparathyroidism, type I distal renal tubular acidosis, medullary sponge kidney, and common calcium oxalate stone formation. In the first three cases—all being conditions commonly associated with nephrocalcinosis—it is shown that the majority of calcifications seen by radiograph may actually be stones. In common calcium oxalate stones formers, it is shown that Randall's plaque can appear as a small calculus on CT scan, even when calyces are known to be completely clear of stones. In the current era with the use of non-contrast CT for the diagnosis of nephrolithiasis, the finding of calcifications in close association with the renal papillae is common. Distinguishing nephrolithiasis from nephrocalcinosis requires direct visual inspection of the papillae and so the diagnosis of nephrocalcinosis is essentially an endoscopic, not radiologic, diagnosis. PMID:21057942
Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar
2016-02-01
Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.
Sutherland, J G H; Miksys, N; Furutani, K M; Thomson, R M
2014-01-01
To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for (125)I, (103)Pd, and (131)Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for (103)Pd seeds and smallest but still considerable differences for (131)Cs seeds. Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.
Tan, Bruce K; Lu, Guanning; Kwasny, Mary J; Hsueh, Wayne D; Shintani-Smith, Stephanie; Conley, David B; Chandra, Rakesh K; Kern, Robert C; Leung, Randy
2013-11-01
Current symptom criteria poorly predict a diagnosis of chronic rhinosinusitis (CRS) resulting in excessive treatment of patients with presumed CRS. The objective of this study was analyze the positive predictive value of individual symptoms, or symptoms in combination, in patients with CRS symptoms and examine the costs of the subsequent diagnostic algorithm using a decision tree-based cost analysis. We analyzed previously collected patient-reported symptoms from a cross-sectional study of patients who had received a computed tomography (CT) scan of their sinuses at a tertiary care otolaryngology clinic for evaluation of CRS symptoms to calculate the positive predictive value of individual symptoms. Classification and regression tree (CART) analysis then optimized combinations of symptoms and thresholds to identify CRS patients. The calculated positive predictive values were applied to a previously developed decision tree that compared an upfront CT (uCT) algorithm against an empiric medical therapy (EMT) algorithm with further analysis that considered the availability of point of care (POC) imaging. The positive predictive value of individual symptoms ranged from 0.21 for patients reporting forehead pain and to 0.69 for patients reporting hyposmia. The CART model constructed a dichotomous model based on forehead pain, maxillary pain, hyposmia, nasal discharge, and facial pain (C-statistic 0.83). If POC CT were available, median costs ($64-$415) favored using the upfront CT for all individual symptoms. If POC CT was unavailable, median costs favored uCT for most symptoms except intercanthal pain (-$15), hyposmia (-$100), and discolored nasal discharge (-$24), although these symptoms became equivocal on cost sensitivity analysis. The three-tiered CART model could subcategorize patients into tiers where uCT was always favorable (median costs: $332-$504) and others for which EMT was always favorable (median costs -$121 to -$275). The uCT algorithm was always more costly if the nasal endoscopy was positive. Among patients with classic CRS symptoms, the frequency of individual symptoms varied the likelihood of a CRS diagnosis marginally. Only hyposmia, the absence of facial pain, and discolored discharge sufficiently increased the likelihood of diagnosis to potentially make EMT less costly. The development of an evidence-based, multisymptom-based risk stratification model could substantially affect the management costs of the subsequent diagnostic algorithm. © 2013 ARS-AAOA, LLC.
Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C
2015-01-01
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice.
Chan, Harley H. L.; Siewerdsen, Jeffrey H.; Vescan, Allan; Daly, Michael J.; Prisman, Eitan; Irish, Jonathan C.
2015-01-01
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice. PMID:26331717
Primary small-bowel malignancy: update in tumor biology, markers, and management strategies.
Shenoy, Santosh
2014-12-01
Primary small-bowel malignancies (SBM) are rare tumors but their incidence is rising. An estimated 9160 new cases and 1210 deaths due to SBM may occur in the USA in 2014. We review advances made in tumor biology, immunohistochemistry, and discuss treatment strategies for these malignancies. Relevant articles from PubMed/Medline and Embase searches were collected using the phrases "small-bowel adenocarcinoma, gastrointestinal carcinoids, gastrointestinal stromal tumors, small-bowel leiomyosarcoma, and small-bowel lymphoma". Advances in imaging techniques such as wireless capsule endoscopy, CT and MRI enterography, and endoscopy (balloon enteroscopy) along with discovery of molecular markers such as c-kit and PDGFRA for GIST tumors have improved our ability to diagnose, localize, and treat these patients. Early detection and surgical resection offers the best chance for long-term survival in all tumors except bowel lymphoma where chemotherapy plays the main role. Adjuvant therapy with imatinib has improved overall survival for GIST tumors, somatostatin analogs have improved symptoms and also inhibited tumor growth and stabilized metastatic disease in carcinoid disease, but chemotherapy has not improved survival for adenocarcinoma. Recent advances in molecular characterization holds promise in novel targeted therapies. Currently ongoing trials are exploring efficacy of targeted therapies and role of adjuvant therapy for adenocarcinoma and results are awaited. Early detection and aggressive surgical therapy for all localized tumors and lymph node sampling particularly for adenocarcinoma remains the main treatment modality.
Diagnostic characteristics of sinonasal organizing hematomas: avoiding misdiagnosis.
Wu, Arthur W; Ting, Jonathan Y; Borgie, Roderick C; Busaba, Nicolas Y; Sadow, Peter M; Juliano, Amy F; Gray, Stacey T; Holbrook, Eric H
2013-07-01
Organizing hematomas of the paranasal sinuses are diagnostic dilemmas clinically and radiographically, mimicking benign or malignant neoplastic processes and causing patients and clinicians undue worry regarding these diagnoses. Diagnostic criteria for correctly identifying these lesions are not well known. A retrospective case series of 7 patients with sinonasal organizing hematoma was studied. Radiographic imaging, clinical characteristics, and pathology were reviewed for new insights. Three patients presented with a primary complaint of epistaxis, 4 had masses visible on nasal endoscopy, and 2 had vascular malformations or small hemangiomas adjacent to the mass found on final pathology. Biopsy of these masses were consistently nondiagnostic prior to complete resection. The most diagnostic findings were "shells" of T2 hypointensity on magnetic resonance imaging (MRI) surrounding the lobules of each of the masses. These correspond to rims of fibrosis at the periphery of the lobules on pathology. Areas of fresh hemorrhage are located at the center of these lobules. Sinonasal organizing hematomas are rare lesions of the paranasal sinuses whose clinical characteristics lead to misdiagnoses of benign or malignant neoplasms. Endoscopy, preoperative biopsy, and computed tomography (CT) imaging do not lend helpful information in differentiating these lesions from more worrisome neoplastic processes. However, MRI can lead to positive diagnosis by recognizing the distinct outer rims of T2 hypointensity typically seen in these lesions. © 2013 ARS-AAOA, LLC.
Duggan, A E; Elliott, C A; Miller, P; Hawkey, C J; Logan, R F A
2009-01-01
Early endoscopy, Helicobacter pylori eradication and empirical acid suppression are commonly used dyspepsia management strategies in primary care but have not been directly compared in a single trial. To compare endoscopy, H. pylori test and refer, H. pylori test and treat and empirical acid suppression for dyspepsia in primary care. Patients presenting to their general practitioner with dyspepsia were randomized to endoscopy, H. pylori'test and treat', H. pylori test and endoscope positives, or empirical therapy with symptoms, patient satisfaction, healthcare costs and cost effectiveness at 12 months being the outcomes. At 2 months, the proportion of patients reporting no or minimal dyspeptic symptoms ranged from 74% for those having early endoscopy to 55% for those on empirical therapy (P = 0.009), but at 1 year, there was little difference among the four strategies. Early endoscopy was associated with fewer subsequent consultations for dyspepsia (P = 0.003). 'Test and treat' resulted in fewer endoscopies overall and was most cost-effective over a range of cost assumptions. Empirical therapy resulted in the lowest initial costs, but the highest rate of subsequent endoscopy. Gastro-oesophageal cancers were found in four patients randomized to the H. pylori testing strategies. While early endoscopy offered some advantages 'Test and treat' was the most cost-effective strategy. In older patients, early endoscopy may be an appropriate strategy in view of the greater risk of malignant disease. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.
Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy
2017-03-01
In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.
Slobounov, Semyon; Sebastianelli, Wayne; Newell, Karl M
2011-01-01
There is a growing concern that traditional neuropsychological (NP) testing tools are not sensitive to detecting residual brain dysfunctions in subjects suffering from mild traumatic brain injuries (MTBI). Moreover, most MTBI patients are asymptomatic based on anatomical brain imaging (CT, MRI), neurological examinations and patients' subjective reports within 10 days post-injury. Our ongoing research has documented that residual balance and visual-kinesthetic dysfunctions along with its underlying alterations of neural substrates may be detected in "asymptomatic subjects" by means of Virtual Reality (VR) graphics incorporated with brain imaging (EEG) techniques.
Software platform for simulation of a prototype proton CT scanner.
Giacometti, Valentina; Bashkirov, Vladimir A; Piersimoni, Pierluigi; Guatelli, Susanna; Plautz, Tia E; Sadrozinski, Hartmut F-W; Johnson, Robert P; Zatserklyaniy, Andriy; Tessonnier, Thomas; Parodi, Katia; Rosenfeld, Anatoly B; Schulte, Reinhard W
2017-03-01
Proton computed tomography (pCT) is a promising imaging technique to substitute or at least complement x-ray CT for more accurate proton therapy treatment planning as it allows calculating directly proton relative stopping power from proton energy loss measurements. A proton CT scanner with a silicon-based particle tracking system and a five-stage scintillating energy detector has been completed. In parallel a modular software platform was developed to characterize the performance of the proposed pCT. The modular pCT software platform consists of (1) a Geant4-based simulation modeling the Loma Linda proton therapy beam line and the prototype proton CT scanner, (2) water equivalent path length (WEPL) calibration of the scintillating energy detector, and (3) image reconstruction algorithm for the reconstruction of the relative stopping power (RSP) of the scanned object. In this work, each component of the modular pCT software platform is described and validated with respect to experimental data and benchmarked against theoretical predictions. In particular, the RSP reconstruction was validated with both experimental scans, water column measurements, and theoretical calculations. The results show that the pCT software platform accurately reproduces the performance of the existing prototype pCT scanner with a RSP agreement between experimental and simulated values to better than 1.5%. The validated platform is a versatile tool for clinical proton CT performance and application studies in a virtual setting. The platform is flexible and can be modified to simulate not yet existing versions of pCT scanners and higher proton energies than those currently clinically available. © 2017 American Association of Physicists in Medicine.
Chen, T N; Yin, X T; Li, X G; Zhao, J; Wang, L; Mu, N; Ma, K; Huo, K; Liu, D; Gao, B Y; Feng, H; Li, F
2018-05-08
Objective: To explore the clinical and teaching application value of virtual reality technology in preoperative planning and intraoperative guide of glioma located in central sulcus region. Method: Ten patients with glioma in the central sulcus region were proposed to surgical treatment. The neuro-imaging data, including CT, CTA, DSA, MRI, fMRI were input to 3dgo sczhry workstation for image fusion and 3D reconstruction. Spatial relationships between the lesions and the surrounding structures on the virtual reality image were obtained. These images were applied to the operative approach design, operation process simulation, intraoperative auxiliary decision and the training of specialist physician. Results: Intraoperative founding of 10 patients were highly consistent with preoperative simulation with virtual reality technology. Preoperative 3D reconstruction virtual reality images improved the feasibility of operation planning and operation accuracy. This technology had not only shown the advantages for neurological function protection and lesion resection during surgery, but also improved the training efficiency and effectiveness of dedicated physician by turning the abstract comprehension to virtual reality. Conclusion: Image fusion and 3D reconstruction based virtual reality technology in glioma resection is helpful for formulating the operation plan, improving the operation safety, increasing the total resection rate, and facilitating the teaching and training of the specialist physician.
Virtual reality simulators: valuable surgical skills trainers or video games?
Willis, Ross E; Gomez, Pedro Pablo; Ivatury, Srinivas J; Mitra, Hari S; Van Sickle, Kent R
2014-01-01
Virtual reality (VR) and physical model (PM) simulators differ in terms of whether the trainee is manipulating actual 3-dimensional objects (PM) or computer-generated 3-dimensional objects (VR). Much like video games (VG), VR simulators utilize computer-generated graphics. These differences may have profound effects on the utility of VR and PM training platforms. In this study, we aimed to determine whether a relationship exists between VR, PM, and VG platforms. VR and PM simulators for laparoscopic camera navigation ([LCN], experiment 1) and flexible endoscopy ([FE] experiment 2) were used in this study. In experiment 1, 20 laparoscopic novices played VG and performed 0° and 30° LCN exercises on VR and PM simulators. In experiment 2, 20 FE novices played VG and performed colonoscopy exercises on VR and PM simulators. In both experiments, VG performance was correlated with VR performance but not with PM performance. Performance on VR simulators did not correlate with performance on respective PM models. VR environments may be more like VG than previously thought. © 2013 Published by Association of Program Directors in Surgery on behalf of Association of Program Directors in Surgery.
A Review of Simulators with Haptic Devices for Medical Training.
Escobar-Castillejos, David; Noguez, Julieta; Neri, Luis; Magana, Alejandra; Benes, Bedrich
2016-04-01
Medical procedures often involve the use of the tactile sense to manipulate organs or tissues by using special tools. Doctors require extensive preparation in order to perform them successfully; for example, research shows that a minimum of 750 operations are needed to acquire sufficient experience to perform medical procedures correctly. Haptic devices have become an important training alternative and they have been considered to improve medical training because they let users interact with virtual environments by adding the sense of touch to the simulation. Previous articles in the field state that haptic devices enhance the learning of surgeons compared to current training environments used in medical schools (corpses, animals, or synthetic skin and organs). Consequently, virtual environments use haptic devices to improve realism. The goal of this paper is to provide a state of the art review of recent medical simulators that use haptic devices. In particular we focus on stitching, palpation, dental procedures, endoscopy, laparoscopy, and orthopaedics. These simulators are reviewed and compared from the viewpoint of used technology, the number of degrees of freedom, degrees of force feedback, perceived realism, immersion, and feedback provided to the user. In the conclusion, several observations per area and suggestions for future work are provided.
NASA Astrophysics Data System (ADS)
Mori, Kensaku; Suenaga, Yasuhito; Toriwaki, Jun-ichiro
2003-05-01
This paper describes a software-based fast volume rendering (VolR) method on a PC platform by using multimedia instructions, such as SIMD instructions, which are currently available in PCs' CPUs. This method achieves fast rendering speed through highly optimizing software rather than an improved rendering algorithm. In volume rendering using a ray casting method, the system requires fast execution of the following processes: (a) interpolation of voxel or color values at sample points, (b) computation of normal vectors (gray-level gradient vectors), (c) calculation of shaded values obtained by dot-products of normal vectors and light source direction vectors, (d) memory access to a huge area, and (e) efficient ray skipping at translucent regions. The proposed software implements these fundamental processes in volume rending by using special instruction sets for multimedia processing. The proposed software can generate virtual endoscopic images of a 3-D volume of 512x512x489 voxel size by volume rendering with perspective projection, specular reflection, and on-the-fly normal vector computation on a conventional PC without any special hardware at thirteen frames per second. Semi-translucent display is also possible.
Low-index discontinuity terahertz waveguides
NASA Astrophysics Data System (ADS)
Nagel, Michael; Marchewka, Astrid; Kurz, Heinrich
2006-10-01
A new type of dielectric THz waveguide based on recent approaches in the field of integrated optics is presented with theoretical and experimental results. Although the guiding mechanism of the low-index discontinuity (LID) THz waveguide is total internal reflection, the THz wave is predominantly confined in the virtually lossless low-index air gap within a high-index dielectric waveguide due to the continuity of electric flux density at the dielectric interface. Attenuation, dispersion and single-mode confinement properties of two LID structures are discussed and compared with other THz waveguide solutions. The new approach provides an outstanding combination of high mode confinement and low transmission losses currently not realizable with any other metal-based or photonic crystal approach. These exceptional properties might enable the breakthrough of novel integrated THz systems or endoscopy applications with sub-wavelength resolution.
Exploring Hominin and Non-hominin Primate Dental Fossil Remains with Neutron Microtomography
NASA Astrophysics Data System (ADS)
Zanolli, Clément; Schillinger, Burkhard; Beaudet, Amélie; Kullmer, Ottmar; Macchiarelli, Roberto; Mancini, Lucia; Schrenk, Friedemann; Tuniz, Claudio; Vodopivec, Vladimira
Fossil dental remains are an archive of unique information for paleobiological studies. Computed microtomography based on X-ray microfocus sources (X-μCT) and Synchrotron Radiation (SR-μCT) allow subtle quantification at the micron and sub-micron scale of the meso- and microstructural signature imprinted in the mineralized tissues, such as enamel and dentine, through high-resolution ;virtual histology;. Nonetheless, depending on the degree of alterations undergone during fossilization, X-ray analyses of tooth tissues do not always provide distinct imaging contrasts, thus preventing the extraction of essential morphological and anatomical details. We illustrate here by three examples the successful application of neutron microtomography (n-μCT) in cases where X-rays have previously failed to deliver contrasts between dental tissues of fossilized specimen.
Guidelines for Safety in the Gastrointestinal Endoscopy Unit
Calderwood, Audrey H.; Chapman, Frank J.; Cohen, Jonathan; Cohen, Lawrence B.; Collins, James; Day, Lukejohn W.; Early, Dayna S.
2014-01-01
EXECUTIVE SUMMARY Historically, safety in the gastrointestinal (GI) endoscopy unit has focused on infection control, particularly around the reprocessing of endoscopes. Two highly publicized outbreaks where the transmission of infectious agents were related to GI endoscopy have highlighted the need to address potential gaps along the endoscopy care continuum that could impact patient safety. PMID:24485393
NASA Astrophysics Data System (ADS)
Hara, Hidetake; Muraishi, Hiroshi; Matsuzawa, Hiroki; Inoue, Toshiyuki; Nakajima, Yasuo; Satoh, Hitoshi; Abe, Shinji
2015-07-01
We have recently developed a phantom that simulates acute ischemic stroke. We attempted to visualize an acute-stage cerebral infarction by using dual-energy Computed tomography (DECT) to obtain virtual monochromatic images of this phantom. Virtual monochromatic images were created by using DECT voltages from 40 to 100 keV in steps of 10 keV and from 60 to 80 keV in steps of 1 keV, under three conditions of the tube voltage with thin (Sn) filters. Calculation of the CNR values allowed us to evaluate the visualization of acute-stage cerebral infarction. The CNR value of a virtual monochromatic image was the highest at 68 keV under 80 kV / Sn 140 kV, at 72 keV under 100 kV / Sn 140 kV, and at 67 keV under 140 kV / 80 kV. The CNR values of virtual monochromatic images at voltages between 65 and 75 keV were significantly higher than those obtained for all other created images. Therefore, the optimal conditions for visualizing acute ischemic stroke were achievable.
Borehole radar interferometry revisited
Liu, Lanbo; Ma, Chunguang; Lane, John W.; Joesten, Peter K.
2014-01-01
Single-hole, multi-offset borehole-radar reflection (SHMOR) is an effective technique for fracture detection. However, commercial radar system limitations hinder the acquisition of multi-offset reflection data in a single borehole. Transforming cross-hole transmission mode radar data to virtual single-hole, multi-offset reflection data using a wave interferometric virtual source (WIVS) approach has been proposed but not fully demonstrated. In this study, we compare WIVS-derived virtual single-hole, multi-offset reflection data to real SHMOR radar reflection profiles using cross-hole and single-hole radar data acquired in two boreholes located at the University of Connecticut (Storrs, CT USA). The field data results are similar to full-waveform numerical simulations developed for a two-borehole model. The reflection from the adjacent borehole is clearly imaged by both the real and WIVS-derived virtual reflection profiles. Reflector travel-time changes induced by deviation of the two boreholes from the vertical can also be observed on the real and virtual reflection profiles. The results of this study demonstrate the potential of the WIVS approach to improve bedrock fracture imaging for hydrogeological and petroleum reservoir development applications.
Miller, G Wilson; Eames, Matthew; Snell, John; Aubry, Jean-François
2015-05-01
Transcranial magnetic resonance-guided focused ultrasound (TcMRgFUS) brain treatment systems compensate for skull-induced beam aberrations by adjusting the phase and amplitude of individual ultrasound transducer elements. These corrections are currently calculated based on a preacquired computed tomography (CT) scan of the patient's head. The purpose of the work presented here is to demonstrate the feasibility of using ultrashort echo-time magnetic resonance imaging (UTE MRI) instead of CT to calculate and apply aberration corrections on a clinical TcMRgFUS system. Phantom experiments were performed in three ex-vivo human skulls filled with tissue-mimicking hydrogel. Each skull phantom was imaged with both CT and UTE MRI. The MR images were then segmented into "skull" and "not-skull" pixels using a computationally efficient, threshold-based algorithm, and the resulting 3D binary skull map was converted into a series of 2D virtual CT images. Each skull was mounted in the head transducer of a clinical TcMRgFUS system (ExAblate Neuro, Insightec, Israel), and transcranial sonications were performed using a power setting of approximately 750 acoustic watts at several different target locations within the electronic steering range of the transducer. Each target location was sonicated three times: once using aberration corrections calculated from the actual CT scan, once using corrections calculated from the MRI-derived virtual CT scan, and once without applying any aberration correction. MR thermometry was performed in conjunction with each 10-s sonication, and the highest single-pixel temperature rise and surrounding-pixel mean were recorded for each sonication. The measured temperature rises were ∼ 45% larger for aberration-corrected sonications than for noncorrected sonications. This improvement was highly significant (p < 10(-4)). The difference between the single-pixel peak temperature rise and the surrounding-pixel mean, which reflects the sharpness of the thermal focus, was also significantly larger for aberration-corrected sonications. There was no significant difference between the sonication results achieved using CT-based and MR-based aberration correction. The authors have demonstrated that transcranial focal heating can be significantly improved in vitro by using UTE MRI to compute skull-induced ultrasound aberration corrections. Their results suggest that UTE MRI could be used instead of CT to implement such corrections on current 0.7 MHz clinical TcMRgFUS devices. The MR image acquisition and segmentation procedure demonstrated here would add less than 15 min to a clinical MRgFUS treatment session.
NASA Astrophysics Data System (ADS)
Lurie, Kristen L.; Zlatev, Dimitar V.; Angst, Roland; Liao, Joseph C.; Ellerbee, Audrey K.
2016-02-01
Bladder cancer has a high recurrence rate that necessitates lifelong surveillance to detect mucosal lesions. Examination with white light cystoscopy (WLC), the standard of care, is inherently subjective and data storage limited to clinical notes, diagrams, and still images. A visual history of the bladder wall can enhance clinical and surgical management. To address this clinical need, we developed a tool to transform in vivo WLC videos into virtual 3-dimensional (3D) bladder models using advanced computer vision techniques. WLC videos from rigid cystoscopies (1280 x 720 pixels) were recorded at 30 Hz followed by immediate camera calibration to control for image distortions. Video data were fed into an automated structure-from-motion algorithm that generated a 3D point cloud followed by a 3D mesh to approximate the bladder surface. The highest quality cystoscopic images were projected onto the approximated bladder surface to generate a virtual 3D bladder reconstruction. In intraoperative WLC videos from 36 patients undergoing transurethral resection of suspected bladder tumors, optimal reconstruction was achieved from frames depicting well-focused vasculature, when the bladder was maintained at constant volume with minimal debris, and when regions of the bladder wall were imaged multiple times. A significant innovation of this work is the ability to perform the reconstruction using video from a clinical procedure collected with standard equipment, thereby facilitating rapid clinical translation, application to other forms of endoscopy and new opportunities for longitudinal studies of cancer recurrence.
Caruso, Damiano; Parinella, Ashley H; Schoepf, U Joseph; Stroebel, Maxwell H; Mangold, Stefanie; Wichmann, Julian L; Varga-Szemes, Akos; Ball, B Devon; De Santis, Domenico; Laghi, Andrea; De Cecco, Carlo N
2017-03-01
To determine the optimal window setting for displaying virtual monoenergetic reconstructions of third generation dual-source, dual-energy CT (DECT) angiography of the abdomen. Forty-five patients were evaluated with DECT angiography (90/150 kV, 180/90 ref. mAs). Three datasets were reconstructed: standard linear blending (M_0.6), 70 keV traditional virtual monoenergetic (M70), and 40 keV advanced noise-optimized virtual monoenergetic (M40+). The best window setting (width and level, W/L) was assessed by two blinded observers and was correlated with aortic attenuation to obtain the Optimized W/L setting (O-W/L). Subjective image quality was assessed, and vessel diameters were measured to determine any possible influences between different W/L settings. Repeated measures of variance were used to evaluate comparison of W/L values, image quality, and vessel sizing between M_0.6, M70, and M40+. The Best W/L (B-W/L) for M70 and M40+ was 880/280 and 1410/450, respectively. Results from regression analysis inferred an O-W/L of 850/270 for M70 and 1350/430 for M40+. Significant differences for W and L were found between the Best and the Optimized W/L for M40+, and between M70 and M40+ for both the Best and Optimized W/L. No significant differences for vessel measurements were found using the O-W/L for M40+ compared to the standard M_0.6 (p ≥ 0.16), and significant differences were observed when using the B-W/L with M40+ compared to M_0.6 (p ≤ 0.04). In order to optimize virtual monoenergetic imaging with both traditional M70 and advanced M40+, adjusting the W/L settings is necessary. Our results suggest a W/L setting of 850/270 for M70 and 1350/430 for M40+.
Safety of capsule endoscopy using human body communication in patients with cardiac devices.
Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young
2012-06-01
The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
Cooper, Gregory S; Kou, Tzyung Doug; Wong, Richard C K
2009-08-01
Upper endoscopy performed within 1 day of presentation, or early endoscopy, has been proposed as an intervention to improve the efficiency and outcomes of care for patients with peptic ulcer hemorrhage. However, the use and outcomes have not been studied in a national, U.S.-based sample. To determine the prevalence and associated outcomes of early versus delayed endoscopy in bleeding peptic ulcers. Using a 5% random sample of inpatient and outpatient Medicare claims from 2004 in patients aged 66 years and older (mean [standard deviation] age 78.4 +/- 7.7 years), we identified 2592 patients, all of whom underwent endoscopy. Univariate and multivariate models were used to determine factors associated with 30-day mortality, upper GI surgery, and length of hospital stay. Early endoscopy was performed in 1854 patients (71.5%) and was somewhat more common with outpatient management. Early endoscopy was independently associated with a significant decrease in the length of hospital stay (-1.95 days, 95% CI, -2.60 to -1.29 days) as well as a lower likelihood of surgery (odds ratio, 0.37; 95% CI, 0.21-0.66). Early endoscopy was not associated with 30-day mortality in either univariate or multivariate analyses. Use of claims data lacking clinical detail and restriction to the Medicare-age population. In this population-based study of older patients with peptic ulcer hemorrhage, early endoscopy was associated with increased efficiency of care, lower rates of surgery, and potentially improved control of hemorrhage. Thus, unless specific contraindications exist, the data support the routine use of early endoscopy.
Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao
2016-01-01
Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-07-07
To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.
Fujiwara, Yasuhiro; Higuchi, Kazuhide; Shiba, Masatsugu; Yamamori, Kazuki; Watanabe, Yoko; Sasaki, Eiji; Tominaga, Kazunari; Watanabe, Toshio; Oshitani, Nobuhide; Arakawa, Tetsuo
2005-04-01
Helicobacter pylori infection and atrophic gastritis are inversely related to erosive esophagitis. Whether these factors affect the pathogenesis of endoscopy-negative reflux disease is not clear. We aimed to elucidate the differences in clinical characteristics between endoscopy-negative erosive disease and erosive esophagitis. 253 subjects (89 with endoscopy-negative reflux disease and 164 with erosive esophagitis) were studied. Gastric atrophy was assessed by measurement of serum pepsinogen. Logistic regression was used to calculate the odds ratio (OR) and 95% confidence intervals (CI) of endoscopy-negative reflux disease compared with erosive esophagitis. Among GERD patients, female gender (OR = 2.27, 95% CI, 1.25-4.10), smoking (OR = 0.45, 95% CI, 0.22-0.91), and the presence of hiatal hernia (OR = 0.30, 95% CI, 0.17-0.56) were significantly associated with endoscopy-negative reflux disease compared with male gender, not smoking, and absence of hiatal hernia, respectively. Body mass index (BMI) was also significantly associated with a decreased OR for endoscopy-negative reflux disease. Although H. pylori infection and gastric atrophy were significantly more common in patients with endoscopy-negative reflux disease, these associations did not persist in a multiple-adjustment model. After adjustment for gender, BMI, smoking, and hiatal hernia, a decrease in serum pepsinogen I/II ratio was significantly associated with an increased OR for endoscopy-negative reflux disease (p for trend = 0.018). Female gender, low BMI, not smoking, absence of hiatal hernia, and severity of gastric atrophy were positively associated with endoscopy-negative reflux disease compared with erosive esophagitis among Japanese patients.
Philipp Bozzini (1773-1809): The earliest description of endoscopy.
Ramai, Daryl; Zakhia, Karl; Etienne, Denzil; Reddy, Madhavi
2018-05-01
The widespread use of endoscopy in today's clinical arena underscores its utility and growing significance within the field of medicine. Primitive forms of endoscopy have existed for hundreds of years, but it was not until the early 19th century that Dr Philipp Bozzini invented an endoscope that would form the basis of modern endoscopy. Born into an influential Italian family, Bozzini practiced medicine in a time and place of conflict and political unrest. His passion, ingenuity, and important social connections allowed him to create and introduce to the medical profession the Lichtleiter (light-conductor), which overcame two key issues plaguing endoscopy: inadequate lighting and poor penetration. A combination of professional rivalry and his premature passing stifled enthusiasm and further work on the Lichtleiter, but its value would not be lost forever. The advancements in the field of endoscopy that have come since the time of the Lichtleiter all build upon the principles of Bozzini, who became widely acknowledged as the father of modern endoscopy.
A nasal osteoma with an acute course in a Japanese Black heifer
SATO, Reiichiro; UNE, Yumi; MADARAME, Hiroo; HANAMI, Hyougo; KANAI, Eiichi; MURAKAMI, Hironobu; TSUKAMOTO, Atsushi; SUZUKI, Takehito; OCHIAI, Hideharu; KIKUCHI, Masato; TANAKA, Hidekazu; ONDA, Ken
2017-01-01
A 14-month-old Japanese Black heifer presented with unilateral epistaxis and mild swelling of the right face. Radiography revealed a mass with increased radiopacity on the right side of the nasal bridge, extending to the left side. Intranasal endoscopy confirmed a large tumor-like structure protruding into the nasal cavity. Following euthanasia, cranial computed tomography (CT) was performed, revealing a tumor 24.3 × 17.5 × 14.8 cm in size. The tumor occupied the entire right nasal cavity and the frontal and sphenoid sinuses. Histopathological examination revealed that the tumor consisted of well-differentiated trabecular bones and loose connective tissue. Based on these findings, a diagnosis of osteoma was established. This report describes a case of osteoma with an acute course in a Japanese Black heifer. PMID:28579581
Han, Yeji; Kim, Hyun Jung; Kong, Kyoung Ae; Kim, Soo Jung; Lee, Su Hwan; Ryu, Yon Ju; Lee, Jin Hwa; Kim, Yookyoung; Shim, Sung Shine
2018-01-01
Background Advances in bronchoscopy and CT-guided lung biopsy have improved the evaluation of small pulmonary lesions (PLs), leading to an increase in preoperative histological diagnosis. We aimed to evaluate the efficacy and safety of transbronchial lung biopsy using radial endobronchial ultrasound and virtual bronchoscopic navigation (TBLB-rEBUS&VBN) and CT-guided transthoracic needle biopsy (CT-TNB) for tissue diagnosis of small PLs. Methods A systematic search was performed in five electronic databases, including MEDLINE, EMBASE, Cochrane Library Central Register of Controlled Trials, Web of Science, and Scopus, for relevant studies in May 2016; the selected articles were assessed using meta-analysis. The articles were limited to those published after 2000 that studied small PLs ≤ 3 cm in diameter. Results From 7345 records, 9 articles on the bronchoscopic (BR) approach and 15 articles on the percutaneous (PC) approach were selected. The pooled diagnostic yield was 75% (95% confidence interval [CI], 69–80) using the BR approach and 93% (95% CI, 90–96) using the PC approach. For PLs ≤ 2 cm, the PC approach (pooled diagnostic yield: 92%, 95% CI: 88–95) was superior to the BR approach (66%, 95% CI: 55–76). However, for PLs > 2 cm but ≤ 3 cm, the diagnostic yield using the BR approach was improved to 81% (95% CI, 75–85). Complications of pneumothorax and hemorrhage were rare with the BR approach but common with the PC approach. Conclusions CT-TNB was superior to TBLB-rEBUS&VBN for the evaluation of small PLs. However, for lesions greater than 2 cm, the BR approach may be considered considering its diagnostic yield of over 80% and the low risk of procedure-related complications. PMID:29357388
Sugisawa, Koichi; Ichikawa, Katsuhiro; Minamishima, Kazuya; Hasegawa, Masakazu; Yamada, Yoshitake; Jinzaki, Masahiro
2017-01-01
The purpose of this study was to evaluate the effect of the virtual monochromatic spectral images (VMSI) and the model-based iterative reconstruction (MBIR) images, to evaluate the influence of the aperture size (40- and 20-mm beam) on renal pseudoenhancement (PE) compared with the filtered back projection (FBP) images. The renal compartment-CT phantom was filled with iodinated contrast material diluted to the attenuation of 180 Hounsfield units (HU) at 120 kV. The water-filled spherical structures, which simulate cyst, were inserted into the renal compartment. Those diameters were 7, 15 and 25 mm. These were scanned by conventional mode (helical scan, 120 kV-FBP) and dual energy mode. 70 keV-VMSI were reconstructed from the dual energy mode, and MBIR images were reconstructed from conventional mode at 40- and 20-mm aperture. Additionally, the phantom was scanned using non-helical mode with 20-mm aperture, and FBP images were reconstructed. The CT value of the PE for cyst areas was measured for these images. The CT values of the cysts were 20.0-14.3 HU on the FBP images, 12.8-12.7 HU on the 70 keV-VMSI (PE-inhibition ratio was 36.0-11.2%) and 16.2-14.0 HU on the MBIR images (19.0-2.1%), respectively, at 40-mm aperture. The PE-inhibition ratio scanned by 20-mm aperture was improved by 28.0% with FBP, 32.8% with 70 keV-VMSI and 29.6% with MBIR compared with 40-mm aperture. One of the FBP images with non-helical mode was 11.6 HU. The best CT technique to minimize PE was the combination of 70 keV-VMSI and 20-mm aperture.
Malik, Anum Imran; Akhtar, Noreen; Loya, Asif; Yusuf, Muhammed Aasim
2014-07-31
Patients suffering from malignancies often undergo serial positron emission tomography - computed tomography (PET-CT) scans, using 2-deoxy-2-[18F] fluoro-D-glucose (FDG) for diagnosis and follow up. This principle may also be applied to benign conditions as inflammatory cells take up increased amounts of FDG as well. The aim of our study was to retrospectively review the cytological diagnoses made at EUS-FNA of FDG-avid PET-CT lesions in patients with a history of cancer and to determine whether the cause of FDG-avidity was neoplastic or benign. We used the endoscopy database to extract clinical information on all patients with malignancies who underwent EUS-FNA to obtain tissue from FDG-avid nodes seen on PET-CT at our institution from 2009 - 2012. All patients who were referred for EUS-FNA after their scans were included. Those who had contraindications to endoscopic procedures were excluded. The most common location of positive lymph nodes was the subcarinal region (46%). A definitive diagnosis was obtained in 87.8% cases, of which 51.2% had a diagnosis of malignancy confirmed on cytology, while 36.5% were benign. Out of these, 29% had granulomatous inflammation. In 12.2% of cases no definitive diagnosis was obtained. Our results show that great caution should be exercised when evaluating FDG-avid PET-CT nodes in patients with known malignant disease, as a significant proportion of these lesions may be benign, particularly in geographic locations with a high background prevalence of granulomatous inflammation.
Sedaghat, Ahmad R; Kieff, David A; Bergmark, Regan W; Cunnane, Mary E; Busaba, Nicolas Y
2015-03-01
Performance of septoplasty is dependent on objective evidence of nasal septal deviation. Although physical examination including anterior rhinoscopy and endoscopic examination is the gold standard for evaluation of septal deviation, third-party payors' reviews of septoplasty claims are often made on computed tomography (CT) findings. However, the correlation between radiographic evaluation of septal deviation with physical examination findings is unknown. Retrospective, blinded, independent evaluation of septal deviation in 39 consecutive patients from physical examination, including anterior rhinoscopy and endoscopic examination, by an otolaryngologist and radiographic evaluation of sinus CT scan by a neuroradiologist. Four distinct septal locations (nasal valve, cartilaginous, inferior/maxillary crest and osseous septum) were evaluated on a 4-point scale representing (1) 0% to 25%, (2) >25% to 50%, (3) >50% to 75%, and (4) >75% obstruction. Correlation between physical examination and radiographic evaluations was made by Pearson's correlation and quantitative agreement assessed by Krippendorf's alpha. Statistically significant correlation was detected between physical examination including nasal endoscopy and radiographic assessment of septal deviation only at the osseous septum (p = 0.007, r = 0.425) with low quantitative agreement (α = 0.290). No significant correlation was detected at the cartilaginous septum (p = 0.286, r = 0.175), inferior septum (p = 0.117, r = 0.255), or nasal valve (p = 0.174, r = 0.222). Quantitative agreement at the nasal valve suggested a bias in CT to underestimate physical exam findings (α = -0.490). CT is a poor substitute for physical examination, the gold standard, in assessment of septal deviation. Clinical decisions about pursuit of septoplasty or third-party payors' decisions to approve septoplasty should not be made on radiographic evidence. © 2014 ARS-AAOA, LLC.
Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis
Palimaka, S; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion) would result in additional expenditure of about $763,000. Limitations In the literature on OGIB, estimates of rebleeding rates after endoscopic procedures or spontaneous cessation rates are unreliable, with a lack of data. Rough estimates from expert consultation can provide an indication of expected additional use of capsule endoscopy; however, a wide range of capsule uses was explored. Conclusions The budgetary impact in the first year in Ontario of capsule endoscopy use to complement push enteroscopy procedures ranges from $510,000 in savings to an additional expenditure of $2,036,000 (at 0% and 100% push enteroscopy procedures complemented, respectively). The expected scenario of 50% of push enteroscopy procedures likely to benefit from the use of capsule endoscopy, based on expert opinion, would result in additional expenditures of $763,000 in the first year. PMID:26355732
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, X; Guild, J; Arbique, G
2015-06-15
Purpose To evaluate the image quality and spectral information of a spectral detector CT (SDCT) scanner using virtual monochromatic (VM) energy images. Methods The SDCT scanner (Philips Healthcare) was equipped with a dual-layer detector and spectral iterative reconstruction (IR), which generates conventional 80–140 kV polychromatic energy (PE) CT images using both detector layers, PE images from the low-energy (upper) and high-energy (lower) detector layers and VM images. A solid water phantom with iodine (2.0–20.0 mg I/ml) and calcium (50.0–600.0 mg Ca/ml) rod inserts was used to evaluate effective energy estimate (EEE) and iodine contrast to noise ratio (CNR). The EEEmore » corresponding to an insert CT number in a PE image was calculated from a CT number fit to the VM image set. Since PE image is prone to beam-hardening artifact EEE may underestimate the actual energy separation from two layers of the detector. A 30-cm-diameter water phantom was used to evaluate noise power spectrum (NPS). The phantoms were scanned at 120 and 140 kV with the same CTDIvol. Results The CT number difference for contrast inserts in VM images (50–150 keV) was 1.3±6% between 120 and 140 kV scans. The difference of EEE calculated from low- and high-energy detector images was 11.5 and 16.7 keV for 120 and 140 kV scans, respectively. The differences calculated from 140 and 100 kV conventional PE images were 12.8, and 20.1 keV from 140 and 80 kV conventional PE images. The iodine CNR increased monotonically with decreased keV. Compared to conventional PE images, the peak of NPS curves from VM images were shifted to lower frequency. Conclusion The EEE results indicates that SDCT at 120 and 140 kV may have energy separation comparable to 100/140 kV and 80/140 kV dual-kV imaging. The effects of IR on CNR and NPS require further investigation for SDCT. Author YY and AD are Philips Healthcare employees.« less
Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.
Li, Yongrui; Li, Ye; Jackson, Alan; Li, Xiaodong; Huang, Ning; Guo, Chunjie; Zhang, Huimao
2017-01-01
To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT. 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing. The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%. VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine flow rates and iodine concentrations, and diagnostic examinations could be acquired with a potential dose saving of 25%.
Deep ensemble learning of virtual endoluminal views for polyp detection in CT colonography
NASA Astrophysics Data System (ADS)
Umehara, Kensuke; Näppi, Janne J.; Hironaka, Toru; Regge, Daniele; Ishida, Takayuki; Yoshida, Hiroyuki
2017-03-01
Robust training of a deep convolutional neural network (DCNN) requires a very large number of annotated datasets that are currently not available in CT colonography (CTC). We previously demonstrated that deep transfer learning provides an effective approach for robust application of a DCNN in CTC. However, at high detection accuracy, the differentiation of small polyps from non-polyps was still challenging. In this study, we developed and evaluated a deep ensemble learning (DEL) scheme for reviewing of virtual endoluminal images to improve the performance of computer-aided detection (CADe) of polyps in CTC. Nine different types of image renderings were generated from virtual endoluminal images of polyp candidates detected by a conventional CADe system. Eleven DCNNs that represented three types of publically available pre-trained DCNN models were re-trained by transfer learning to identify polyps from the virtual endoluminal images. A DEL scheme that determines the final detected polyps by a review of the nine types of VE images was developed by combining the DCNNs using a random forest classifier as a meta-classifier. For evaluation, we sampled 154 CTC cases from a large CTC screening trial and divided the cases randomly into a training dataset and a test dataset. At 3.9 falsepositive (FP) detections per patient on average, the detection sensitivities of the conventional CADe system, the highestperforming single DCNN, and the DEL scheme were 81.3%, 90.7%, and 93.5%, respectively, for polyps ≥6 mm in size. For small polyps, the DEL scheme reduced the number of false positives by up to 83% over that of using a single DCNN alone. These preliminary results indicate that the DEL scheme provides an effective approach for improving the polyp detection performance of CADe in CTC, especially for small polyps.
Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong
2013-01-01
Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583
Augmented Reality Robot-assisted Radical Prostatectomy: Preliminary Experience.
Porpiglia, Francesco; Fiori, Cristian; Checcucci, Enrico; Amparore, Daniele; Bertolo, Riccardo
2018-05-01
To present our preliminary experience with augmented reality robot-assisted radical prostatectomy (AR-RARP). From June to August 2017, patients candidate to RARP were enrolled and underwent high-resolution multi-parametric magnetic resonance imaging (1-mm slices) according to dedicated protocol. The obtained three-dimensional (3D) reconstruction was integrated in the robotic console to perform AR-RARP. According to the staging at magnetic resonance imaging or reconstruction, in case of cT2 prostate cancer, intrafascial nerve sparing (NS) was performed: a mark was placed on the prostate capsule to indicate the virtual underlying intraprostatic lesion; in case of cT3, standard NS AR-RARP was scheduled with AR-guided biopsy at the level of suspected extracapsular extension (ECE). Prostate specimens were scanned to assess the 3D model concordance. Sixteen patients underwent intrafascial NS technique (cT2), whereas 14 underwent standard NS+ selective biopsy of suspected ECE (cT3). Final pathology confirmed clinical staging. Positive surgical margins' rate was 30% (no positive surgical margins in pT2). In patients whose intraprostatic lesions were marked, final pathology confirmed lesion location. In patients with suspected ECE, AR-guided selective biopsies confirmed the ECE location, with 11 of 14 biopsies (78%) positive for prostate cancer. Prostate specimens were scanned with finding of a good overlap. The mismatch between 3D reconstruction and scanning ranged from 1 to 5 mm. In 85% of the entire surface, the mismatch was <3 mm. In our preliminary experience, AR-RARP seems to be safe and effective. The accuracy of 3D reconstruction seemed to be promising. This technology has still limitations: the virtual models are manually oriented and rigid. Future collaborations with bioengineers will allow overcoming these limitations. Copyright © 2018 Elsevier Inc. All rights reserved.
Lundin, Margareta; Lidén, Mats; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Geijer, Håkan; Andersson, Torbjörn; Persson, Anders
2012-07-01
Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.
Daniel, Kaemmerer; Maria, Athelogou; Amelie, Lupp; Isabell, Lenhardt; Stefan, Schulz; Luisa, Peter; Merten, Hommann; Vikas, Prasad; Gerd, Binnig; Paul, Baum Richard
2014-01-01
Background: Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT. Methods: We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score “BB1” was created for comparing the manual and automated analysis of SSTR expression. Results: BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).Conclusion: Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides (“virtual microscopy”), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging. PMID:25197368
Cha, Jihoon; Kim, Hyung-Jin; Kim, Sung Tae; Kim, Yi Kyung; Kim, Ha Youn; Park, Gyeong Min
2017-11-01
Background Metallic dental prostheses may degrade image quality on head and neck computed tomography (CT). However, there is little information available on the use of dual-energy CT (DECT) and metal artifact reduction software (MARS) in the head and neck regions to reduce metallic dental artifacts. Purpose To assess the usefulness of DECT with virtual monochromatic imaging and MARS to reduce metallic dental artifacts. Material and Methods DECT was performed using fast kilovoltage (kV)-switching between 80-kV and 140-kV in 20 patients with metallic dental prostheses. CT data were reconstructed with and without MARS, and with synthesized monochromatic energy in the range of 40-140-kiloelectron volt (keV). For quantitative analysis, the artifact index of the tongue, buccal, and parotid areas was calculated for each scan. For qualitative analysis, two radiologists evaluated 70-keV and 100-keV images with and without MARS for tongue, buccal, parotid areas, and metallic denture. The locations and characteristics of the MARS-related artifacts, if any, were also recorded. Results DECT with MARS markedly reduced metallic dental artifacts and improved image quality in the buccal area ( P < 0.001) and the tongue ( P < 0.001), but not in the parotid area. The margin and internal architecture of the metallic dentures were more clearly delineated with MARS ( P < 0.001) and in the higher-energy images than in the lower-energy images ( P = 0.042). MARS-related artifacts most commonly occurred in the deep center of the neck. Conclusion DECT with MARS can reduce metallic dental artifacts and improve delineation of the metallic prosthesis and periprosthetic region.
Delivering an Online Translation Course
ERIC Educational Resources Information Center
Campbell, Dermot F.
2004-01-01
This presentation is a discursive treatment of the migration of a classroom based translation class to online delivery using the Virtual Learning Environment WebCT. The main focus is not on the VLE itself, but on the pedagogical challenges posed by the move to online delivery and the course structure developed to retain as many of the advantages…
Pérez-Mendoza, A; Zárate-Guzmán, Á M; Galvis García, E S; Sobrino Cossío, S; Djamus Birch, J
Gastric cancer is one of the main causes of cancer worldwide, but there is currently no global screening strategy for the disease. Endoscopy is the screening method of choice in some Asian countries, but no standardized technique has been recognized. Systematic alphanumeric-coded endoscopy can increase gastric lesion detection. The aim of the present article was to compare the usefulness of systematic alphanumeric-coded endoscopy with conventional endoscopy for the detection of premalignant lesions and early gastric cancer in subjects at average risk for gastric cancer. A cross-sectional, comparative, prospective, randomized study was conducted on patients at average risk for gastric cancer (40-50 years of age, no history of H. pylori infection, intestinal metaplasia, gastric atrophy, or gastrointestinal surgery). Before undergoing endoscopy, the patients had gastric preparation (200mg of oral acetylcysteine or 50mg of oral dimethicone). Conventional chromoendoscopy was performed with indigo carmine dye for contrast enhancement. Fifty consecutive cases (mean age 44.4 ± 3.34 years, 60% women, BMI 27.6 ± 5.82 kg/m 2 ) were evaluated. Endoscopic imaging quality was satisfactory in all the cases, with no differences between methods (p = 0.817). The detection rate of premalignant lesions and early gastric cancer was 14% (6 cases of intestinal metaplasia and one case of gastric adenocarcinoma). Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 95, 80, 100 and 96%, respectively, for systematic alphanumeric-coded endoscopy, and 100, 45, 20, 100, and 52%, respectively, for conventional endoscopy. Lesion detection through systematic alphanumeric-coded endoscopy was superior to that of conventional endoscopy (p = 0.003; OR = 12). Both techniques were effective, but systematic alphanumeric-coded endoscopy significantly reduced the false positive rate. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Loftus, Russell; Nugent, Zoann; Graff, Lesley A; Schumacher, Frederick; Bernstein, Charles N; Singh, Harminder
2013-01-01
Patient experiences with endoscopy visits within a large central Canadian health region were evaluated to determine the relationship between the visit experience and the patients' willingness to return for future endoscopy, and to identify the factors associated with patients' willingness to return. A self-report survey was distributed to 1200 consecutive individuals undergoing an upper and⁄or lower gastrointestinal endoscopy at any one of the six hospital-based endoscopy facilities in the region. The Spearman correlation coefficient was used to assess the association between the patients' overall rating of the visits and willingness to return for repeat procedures under similar medical circumstances. Logistic regression analyses were performed to identify the factors associated with willingness to return for repeat endoscopy and overall satisfaction (rating) of the visit. A total of 529 (44%) individuals returned the questionnaire, with 45% rating the visit as excellent and 56% indicating they were extremely likely to return for repeat endoscopy. There was a low moderate correlation between overall rating of the visit and patients' willingness to return for repeat endoscopy (r=0.30). The factors independently associated with patient willingness to return for repeat endoscopy included perceived technical skills of the endoscopists (OR 2.7 [95% CI 1.3 to 5.5]), absence of pain during the procedure (OR 2.2 [95% CI 1.3 to 3.6]) and history of previous endoscopy (OR 2.4 [95% CI 1.4 to 4.1]). In contrast, the independent factors associated with the overall rating of the visit included information provided pre- and postprocedure, wait time before and on the day of the visit, and the physical environment. To facilitate patient return for needed endoscopy, it is important to assess patients' willingness to return because positive behavioural intent is not simply a function of satisfaction with the visit.
Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dubé, Catherine; Enns, Robert; Hollingworth, Roger; MacIntosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J; Valori, Roland
2012-01-01
BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. OBJECTIVE: To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. METHODS: A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. RESULTS: Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. DISCUSSION: The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. CONCLUSIONS: The guidelines support quality improvement in endoscopy by providing explicit recommendations on systematic monitoring, assessment and modification of endoscopy service delivery to yield benefits for all patients affected by the practice of gastrointestinal endoscopy. PMID:22308578
Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N
2013-02-01
Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Welter, S; Stöcker, C; Dicken, V; Kühl, H; Krass, S; Stamatis, G
2012-03-01
Segmental resection in stage I non-small cell lung cancer (NSCLC) has been well described and is considered to have similar survival rates as lobectomy but with increased rates of local tumour recurrence due to inadequate parenchymal margins. In consequence, today segmentectomy is only performed when the tumour is smaller than 2 cm. Three-dimensional reconstructions from 11 thin-slice CT scans of bronchopulmonary segments were generated, and virtual spherical tumours were placed over the segments, respecting all segmental borders. As a next step, virtual parenchymal safety margins of 2 cm and 3 cm were subtracted and the size of the remaining tumour calculated. The maximum tumour diameters with a 30-mm parenchymal safety margin ranged from 26.1 mm in right-sided segments 7 + 8 to 59.8 mm in the left apical segments 1-3. Using a three-dimensional reconstruction of lung CT scans, we demonstrated that segmentectomy or resection of segmental groups should be feasible with adequate margins, even for larger tumours in selected cases. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Zhang, Ming-cai; Lü, Si-zhe; Cheng, Ying-wu; Gu, Li-xu; Zhan, Hong-sheng; Shi, Yin-yu; Wang, Xiang; Huang, Shi-rong
2011-02-01
To study the effect of vertebrae semi-dislocation on the stress distribution in facet joint and interuertebral disc of patients with cervical syndrome using three dimensional finite element model. A patient with cervical spondylosis was randomly chosen, who was male, 28 years old, and diagnosed as cervical vertebra semidislocation by dynamic and static palpation and X-ray, and scanned from C(1) to C(7) by 0.75 mm slice thickness of CT. Based on the CT data, the software was used to construct the three dimensional finite element model of cervical vertebra semidislocation (C(4)-C(6)). Based on the model,virtual manipulation was used to correct the vertebra semidislocation by the software, and the stress distribution was analyzed. The result of finite element analysis showed that the stress distribution of C(5-6) facet joint and intervertebral disc changed after virtual manipulation. The vertebra semidislocation leads to the abnormal stress distribution of facet joint and intervertebral disc.
[Value of narrow band imaging endoscopy in detection of early laryngeal squamous cell carcinoma].
Staníková, L; Kučová, H; Walderová, R; Zeleník, K; Šatanková, J; Komínek, P
2015-01-01
Narrow band imaging (NBI) is an endoscopic method using filtered wavelengths in detection of microvascular abnormalities associated with preneoplastic and neoplastic changes of the mucosa. The aim of the study is to evaluate the value of NBI endoscopy in the dia-gnosis of laryngeal precancerous and early stages of cancerous lesions and to investigate impact of NBI method in prehistological diagnostics in vivo. One hundred patients were enrolled in the study and their larynx was investigated using white light HD endoscopy and narrow band imaging between 6/ 2013- 10/ 2014. Indication criteria included chronic laryngitis, hoarseness for more than three weeks or macroscopic laryngeal lesion. Features of mucosal lesions were evaluated by white light endoscopy and afterwards were compared with intra-epithelial papillary capillary loop changes, viewed using NBI endoscopy. Suspicious lesions (leukoplakia, exophytic tumors, recurrent respiratory papillomatosis and/ or malignant type of vascular network by NBI endoscopy) were evaluated by histological analysis, results were compared with prehistological NBI dia-gnosis. Using NBI endoscopy, larger demarcation of pathological mucosal features than in white light visualization were recorded in 32/ 100 (32.0%) lesions, in 4/ 100 (4.0%) cases even new lesions were detected only by NBI endoscopy. 63/ 100 (63.0%) suspected lesions were evaluated histologically - malign changes (carcinoma in situ or invasive carcinoma) were observed in 25/ 63 (39.7%). Prehistological diagnostics of malignant lesions using NBI endoscopy were in agreement with results of histological examination in 23/ 25 (92.0%) cases. The sensitivity of NBI in detecting malignant lesions was 89.3%, specificity of this method was 94.9%. NBI endoscopy is a promising optical technique enabling in vivo differentiation of superficial neoplastic lesions. These results suggest endoscopic NBI may be useful in the early detection of laryngeal cancer and precancerous lesions.
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-01-01
AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396
Loots, E; Clarke, D L; Newton, K; Mulder, C J
2017-10-31
Endoscopy services are central to the diagnosis and management of many gastrointestinal (GI) diseases. To evaluate the adequacy of endoscopy services in the public sector hospitals of KwaZulu-Natal (KZN) Province, South Africa, in 2016. A cross-sectional study was performed using a questionnaire completed by the clinical heads of endoscopy units in the public hospitals in KZN. The heads of 11 of the 12 endoscopy units responded. Two units were in tertiary-level hospitals and nine in regional hospitals. A total of 22 353 endoscopic procedures were performed annually, averaging 2 032 cases per annum per centre; they were performed by 89 endoscopists, of whom 72 (80.1%) were general surgeons. There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 - 60) days, for colonoscopy 29 (range 7 - 90) days and for duodenoscopy/endoscopic retrograde cholangiopancreatography 13 (range 4 - 20) days. This included patients with alarm symptoms for GI cancers. Equipment breakages interrupted most services, except for one hospital that had a service contract. Unit heads cited lack of equipment, trained staff and maintenance contracts as major shortcomings. Endoscopy units in KZN are not adequately equipped to deal with the endoscopy workload and services are plagued by frequent disruptions, which impact negatively on service delivery. There is a need to train more GEs. Patient care is compromised in these public hospitals.
Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Yoshiya, Kazuhisa; Shimazu, Takeshi; Tomiyama, Noriyuki
2014-04-01
Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.
An evaluation on CT image acquisition method for medical VR applications
NASA Astrophysics Data System (ADS)
Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang
2017-02-01
Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.
Standardization and Optimization of Computed Tomography Protocols to Achieve Low-Dose
Chin, Cynthia; Cody, Dianna D.; Gupta, Rajiv; Hess, Christopher P.; Kalra, Mannudeep K.; Kofler, James M.; Krishnam, Mayil S.; Einstein, Andrew J.
2014-01-01
The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities and various indications require unique protocols, but there remains room for standardization and optimization. In this paper we summarize approaches to reduce dose, as discussed in lectures comprising the first session of the 2013 UCSF Virtual Symposium on Radiation Safety in Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing-tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose. PMID:24589403
Patient-specific CT dosimetry calculation: a feasibility study.
Fearon, Thomas; Xie, Huchen; Cheng, Jason Y; Ning, Holly; Zhuge, Ying; Miller, Robert W
2011-11-15
Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient-specific CT dosimetry. A radiation treatment planning system was modified to calculate patient-specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose-volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi-empirical, measured correction-based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point-by-point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%-20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient-specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation.
Tringali, Andrea; Thomson, Mike; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf Dietrich; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro
2017-01-01
This Executive summary of the Guideline on pediatric gastrointestinal endoscopy from the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) refers to infants, children, and adolescents aged 0 - 18 years. The areas covered include: indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; endoscopic management of corrosive ingestion and stricture/stenosis; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography, and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease (IBD) have been dealt with in other Guidelines and are therefore not mentioned in this Guideline. Training and ongoing skill maintenance will be addressed in an imminent sister publication. © Georg Thieme Verlag KG Stuttgart · New York.
Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D
2017-01-01
The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745
From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.
Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas
2016-12-01
Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.
Klibansky, David; Rothstein, Richard I
2012-09-01
The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.
de Boer, I R; Wesselink, P R; Vervoorn, J M
2013-11-01
To describe the development and opportunities for implementation of virtual teeth with and without pathology for use in a virtual learning environment in dental education. The creation of virtual teeth begins by scanning a tooth with a cone beam CT. The resulting scan consists of multiple two-dimensional grey-scale images. The specially designed software program ColorMapEditor connects these two-dimensional images to create a three-dimensional tooth. With this software, any aspect of the tooth can be modified, including its colour, volume, shape and density, resulting in the creation of virtual teeth of any type. This article provides examples of realistic virtual teeth with and without pathology that can be used for dental education. ColorMapEditor offers infinite possibilities to adjust and add options for the optimisation of virtual teeth. Virtual teeth have unlimited availability for dental students, allowing them to practise as often as required. Virtual teeth can be made and adjusted to any shape with any type of pathology. Further developments in software and hardware technology are necessary to refine the ability to colour and shape the interior of the pulp chamber and surface of the tooth to enable not only treatment but also diagnostics and thus create a greater degree of realism. The creation and use of virtual teeth in dental education appears to be feasible but is still in development; it offers many opportunities for the creation of teeth with various pathologies, although an evaluation of its use in dental education is still required. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A new methodological approach for PET implementation in radiotherapy treatment planning.
Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello
2012-05-01
In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutherland, J. G. H.; Miksys, N.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca
2014-01-15
Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxelmore » and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.« less
Li, Yunfeng; Jiang, Yangmei; Zhang, Nan; Xu, Rui; Hu, Jing; Zhu, Songsong
2015-03-01
Computer-aided jaw surgery has been extensively studied recently. The purpose of this study was to determine the clinical feasibility of performing bimaxillary orthognathic surgery without intermediate splint using virtual surgical planning and rapid prototyping technology. Twelve consecutive patients who underwent bimaxillary orthognathic surgery were included. The presented treatment plan here mainly consists of 6 procedures: (1) data acquisition from computed tomography (CT) of the skull and laser scanning of the dentition; (2) reconstruction and fusion of a virtual skull model with accurate dentition; (3) virtual surgery simulation including osteotomy and movement and repositioning of bony segments; (4) final surgical splint fabrication (no intermediate splint) using computer-aided design and rapid prototyping technology; (5) transfer of the virtual surgical plan to the operating room; and (6) comparison of the actual surgical outcome to the virtual surgical plan. All procedures of the treatment were successfully performed on all 12 patients. In quantification of differences between simulated and actual postoperative outcome, we found that the mean linear difference was less than 1.8 mm, and the mean angular difference was less than 2.5 degrees in all evaluated patients. Results from this study suggested that it was feasible to perform bimaxillary orthognathic surgery without intermediate splint. Virtual surgical planning and the guiding splints facilitated the diagnosis, treatment planning, accurate osteotomy, and bony segments repositioning in orthognathic surgery.
Light and sound - emerging imaging techniques for inflammatory bowel disease
Knieling, Ferdinand; Waldner, Maximilian J
2016-01-01
Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography. PMID:27433080
[Quality assurance of a virtual simulation software: application to IMAgo and SIMAgo (ISOgray)].
Isambert, A; Beaudré, A; Ferreira, I; Lefkopoulos, D
2007-06-01
Virtual simulation process is often used to prepare three dimensional conformal radiation therapy treatments. As the quality of the treatment is widely dependent on this step, it is mandatory to perform extensive controls on this software before clinical use. The tests presented in this work have been carried out on the treatment planning system ISOgray (DOSIsoft), including the delineation module IMAgo and the virtual simulation module SIMAgo. According to our experience, the most relevant controls of international protocols have been selected. These tests mainly focused on measuring and delineation tools, virtual simulation functionalities, and have been performed with three phantoms: the Quasar Multi-Purpose Body Phantom, the Quasar MLC Beam Geometry Phantom (Modus Medical Devices Inc.) and a phantom developed at Hospital Tenon. No major issues have been identified while performing the tests. These controls have emphasized the necessity for the user to consider with a critical eye the results displayed by a virtual simulation software. The contrast of visualisation, the slice thickness, the calculation and display mode of 3D structures used by the software are many factors of uncertainties. A virtual simulation software quality assurance procedure has been written and applied on a set of CT images. Similar tests have to be performed periodically and at minimum at each change of major version.
Stereoscopic virtual reality models for planning tumor resection in the sellar region.
Wang, Shou-sen; Zhang, Shang-ming; Jing, Jun-jie
2012-11-28
It is difficult for neurosurgeons to perceive the complex three-dimensional anatomical relationships in the sellar region. To investigate the value of using a virtual reality system for planning resection of sellar region tumors. The study included 60 patients with sellar tumors. All patients underwent computed tomography angiography, MRI-T1W1, and contrast enhanced MRI-T1W1 image sequence scanning. The CT and MRI scanning data were collected and then imported into a Dextroscope imaging workstation, a virtual reality system that allows structures to be viewed stereoscopically. During preoperative assessment, typical images for each patient were chosen and printed out for use by the surgeons as references during surgery. All sellar tumor models clearly displayed bone, the internal carotid artery, circle of Willis and its branches, the optic nerve and chiasm, ventricular system, tumor, brain, soft tissue and adjacent structures. Depending on the location of the tumors, we simulated the transmononasal sphenoid sinus approach, transpterional approach, and other approaches. Eleven surgeons who used virtual reality models completed a survey questionnaire. Nine of the participants said that the virtual reality images were superior to other images but that other images needed to be used in combination with the virtual reality images. The three-dimensional virtual reality models were helpful for individualized planning of surgery in the sellar region. Virtual reality appears to be promising as a valuable tool for sellar region surgery in the future.
Shaheen, Nicholas J; Denison, Hans; Björck, Karin; Silberg, Debra G
2013-04-01
Approximately 20-30% of patients with gastroesophageal reflux disease (GERD) do not experience complete symptom resolution during proton pump inhibitor (PPI) therapy. The aim of this study was to determine the prevalence of esophageal mucosal breaks among patients who have a partial response to PPI therapy. This was an analysis of data from a phase 2b clinical trial carried out to assess the efficacy and safety of a reflux inhibitor, lesogaberan (AZD3355), as an add-on to PPI therapy in this patient population (clinicaltrials.gov reference: NCT01005251). A total of 661 patients with persistent GERD symptoms who had received a minimum of 4 weeks of PPI therapy were included in the study. The prevalence of esophageal mucosal breaks was assessed according to (i) the most recent endoscopy results from within the previous 24 months, if available ("historical" endoscopies), and (ii) the results of endoscopies performed at study baseline ("baseline" endoscopies). Baseline endoscopies were not carried out in patients who had a historical endoscopy showing an absence of esophageal mucosal breaks. Historical endoscopy results were available for 244 patients, of whom 48 (19.7%) had esophageal mucosal breaks. Baseline endoscopies were carried out in 465 patients, of whom 146 (31.4%) had esophageal mucosal breaks. Sensitivity analyses showed a prevalence of esophageal mucosal breaks of 20-30%. In both the historical and baseline endoscopies, most esophageal mucosal breaks were Los Angeles grades A or B. In patients with GERD symptoms partially responsive to PPI therapy, mild-to-moderate severity esophageal mucosal breaks are common (prevalence 20-30%), and may contribute to symptom etiology.
Tomizawa, Minoru; Shinozaki, Fuminobu; Hasegawa, Rumiko; Togawa, Akira; Shirai, Yoshinori; Ichiki, Noboru; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Sueishi, Makoto
2014-02-07
To investigate the early upper gastrointestinal endoscopy (endoscopy) significantly reduces mortality resulting from upper gastrointestinal (GI) bleeding. Upper GI bleeding was defined as 1a, 1b, 2a, and 2b according to the Forrest classification. The hemoglobin (Hb), and C-reactive protein (CRP) were examined at around the day of endoscopy and 3 mo prior to endoscopy. The rate of change was calculated as follows: (the result of blood examination on the day of endoscopy - the results of blood examination 3 mo prior to endoscopy)/(results of blood examination 3 mo prior to endoscopy). Receiver operating characteristic curves were created to determine threshold values. Seventy-nine men and 77 women were enrolled. There were 17 patients with upper GI bleeding: 12 with a gastric ulcer, 3 with a duodenal ulcer, 1 with an acute gastric mucosal lesion, and 1 with gastric cancer. The area under the curve (AUC), threshold, sensitivity, and specificity of Hb around the day of endoscopy were 0.902, 11.7 g/dL, 94.1%, and 77.1%, respectively, while those of CRP were 0.722, 0.5 mg/dL, 70.5%, and 73%, respectively. The AUC, threshold, sensitivity, and specificity of the rate of change of Hb were 0.851, -21.3%, 76.4%, and 82.6%, respectively, while those of CRP were 0.901, 100%, 100%, and 82.5%, respectively. Predictors for upper GI bleeding were Hb < 11.7 g/dL, reduction rate in the Hb > 21.3% and an increase in the CRP > 100%, 3 mo before endoscopy.
Law, T T; Tong, Daniel; Wong, Sam W H; Chan, S Y; Law, Simon
2015-04-01
Gastric mucosa-associated lymphoid tissue lymphoma is uncommon and most patients have an indolent clinical course. The clinical presentation and endoscopic findings can be subtle and diagnosis can be missed on white light endoscopy. Magnifying endoscopy may help identify the abnormal microstructural and microvascular patterns, and target biopsies can be performed. We describe herein the case of a 64-year-old woman with Helicobacter pylori-negative gastric mucosa-associated lymphoid tissue lymphoma diagnosed by screening magnification endoscopy. Helicobacter pylori-eradication therapy was given and she received biological therapy. She is in clinical remission after treatment. The use of magnification endoscopy in gastric mucosa-associated lymphoid tissue lymphoma and its management are reviewed.
NASA Astrophysics Data System (ADS)
Huang, Zhiwei; Bergholt, Mads Sylvest; Zheng, Wei; Ho, Khek Yu; Yeoh, Khay Guan; Teh, Ming; So, Jimmy Bok Yan; Shabbir, Asim
2013-03-01
A rapid image-guided Raman endoscopy system integrated with on-line diagnostic scheme is developed for in vivo Raman tissue diagnosis (optical biopsy) in the upper GI during clinical gastrointestinal endoscopy under multimodal wide-field imaging guidance. The real-time Raman endoscopy technique was tested prospectively on new gastric patients (n=4) and could identify dysplasia in vivo with sensitivity of 81.5% (22/27) and specificity of 87.9% (29/33). This study realizes for the first time the novel image-guided Raman endoscopy as a screening tool for real-time, online diagnosis of gastric cancer and precancer in vivo at endoscopy.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru
2007-03-01
Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.
Flexible Gastrointestinal Endoscopy in Ferrets (Mustela putorius furo).
Pignon, Charly; Huynh, Minh; Husnik, Roman; Jekl, Vladimir
2015-09-01
Gastrointestinal disease is a common complaint in ferrets (Mustela putorius furo). Their relatively simple and short gastrointestinal tract makes them good candidates for flexible endoscopy. However, apart from a few references in biomedical research articles, there is little information on the use of flexible endoscopy in ferrets. This review describes patient preparation, equipment, and select gastrointestinal endoscopy techniques in ferrets, including esophagoscopy, gastroscopy, duodenoscopy, percutaneous endoscopic gastrostomy, jejunoileoscopy, colonoscopy, and biopsy. Copyright © 2015 Elsevier Inc. All rights reserved.
Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.
Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A
2008-07-01
Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.
Dual energy CT kidney stone differentiation in photon counting computed tomography
NASA Astrophysics Data System (ADS)
Gutjahr, R.; Polster, C.; Henning, A.; Kappler, S.; Leng, S.; McCollough, C. H.; Sedlmair, M. U.; Schmidt, B.; Krauss, B.; Flohr, T. G.
2017-03-01
This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS), and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated. The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≍ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.
NASA Astrophysics Data System (ADS)
Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou
2006-03-01
Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.
ERIC Educational Resources Information Center
Tirado, Ramon; Aguaded, Ignacio; Hernando, Angel
2011-01-01
This article analyses an experience in collaborative learning in an asynchronous writing environment through discussion forums on a WebCt platform of the University of Huelva's virtual campus, and was part of an innovative teaching project in 2007-08. The main objectives are to describe the processes of collaborative knowledge construction and the…
Comparative Study of Platforms for E-Learning in the Higher Education
ERIC Educational Resources Information Center
Mondejar-Jimenez, Jose; Mondejar-Jimenez, Juan-Antonio; Vargas-Vargas, Manuel; Meseguer-Santamaria, Maria-Leticia
2008-01-01
Castilla-La Mancha University has decided to implement two tools: WebCT and Moodle, "Virtual Campus" has emerged: www.campusvirtual.ulcm.es. This paper is dedicated to the analysis of said tool as a primary mode of e-learning expansion in the university environment. It can be used to carry out standard educational university activities…
Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea
2015-08-01
Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate hernias. Comparison CT of the 28 patients with a hiatal hernia at CTC showed the absence of the hernia in 57.1 % (16/28) patients, including 68.8 % (11/16) and 50 % (5/10) of small and moderate hernias. The prevalence of sliding hiatal hernias in the external control group was 22 % (44/200), significantly lower than the CT-WE and CTC cohorts' prevalence of 51 % (p < 0.0001) and 48.5 % (p < 0.0001). After applying the correction factors for the CT-WE and the CTC groups, the estimated residual prevalences (16 and 18.5 %, respectively) were much closer to that of the external control patients (p = 0.160 for CT-WE and p = 0.455 for CTC). We believe that incidental findings at CT-WE and CTC should be considered according to the clinical background, and that small sliding hiatal hernias should not be reported in patients with symptoms not related to reflux disease undergoing CT-WE or CTC: When encountering these findings, accurate anamnesis and review of medical history looking for GERD-related symptoms are essential, in order to address these patients to a correct diagnostic iter, taking advantage from more appropriate techniques such as endoscopy or functional techniques.
NASA Astrophysics Data System (ADS)
Saenz, Daniel L.; Kim, Hojin; Chen, Josephine; Stathakis, Sotirios; Kirby, Neil
2016-09-01
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu’s method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
Landschoff, Jannes; Du Plessis, Anton; Griffiths, Charles L
2018-04-01
Along with the conventional deposition of physical types at natural history museums, the deposition of 3-dimensional (3D) image data has been proposed for rare and valuable museum specimens, such as irreplaceable type material. Micro computed tomography (μCT) scan data of 5 hermit crab species from South Africa, including rare specimens and type material, depicted main identification characteristics of calcified body parts. However, low-image contrasts, especially in larger (>50 mm total length) specimens, did not allow sufficient 3D reconstructions of weakly calcified and fine characteristics, such as soft tissue of the pleon, mouthparts, gills, and setation. Reconstructions of soft tissue were sometimes possible, depending on individual sample and scanning characteristics. The raw data of seven scans are publicly available for download from the GigaDB repository. Calcified body parts visualized from μCT data can aid taxonomic validation and provide additional, virtual deposition of rare specimens. The use of a nondestructive, nonstaining μCT approach for taxonomy, reconstructions of soft tissue structures, microscopic spines, and setae depend on species characteristics. Constrained to these limitations, the presented dataset can be used for future morphological studies. However, our virtual specimens will be most valuable to taxonomists who can download a digital avatar for 3D examination. Simultaneously, in the event of physical damage to or loss of the original physical specimen, this dataset serves as a vital insurance policy.
Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano
2016-02-01
The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P < 0.0001). However, following endoscopy, patients reported a significantly better experience with TEE compared with standard endoscopy (7.05 ± 0.49 vs. 4.35 ± 0.53; P = 0.0006), with 60 % preferring TEE and 25 % preferring sedated standard endoscopy. In this study, TEE had equal accuracy for an endoscopic diagnosis of Barrett's esophagus compared with standard endoscopy, at the expense of reduced image quality and a lower yield of intestinal metaplasia on biopsy. TEE was better tolerated and preferred by patients. Hence, TEE needs further evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.
Leadership and team building in gastrointestinal endoscopy.
Valori, Roland M; Johnston, Deborah J
2016-06-01
A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link-http://www.qsfh.co.uk/Page.aspx?PageId=Public). Copyright © 2016 Elsevier Ltd. All rights reserved.
Colonoscopy in the office setting is safe, and financially sound ... for now.
Luchtefeld, Martin A; Kim, Donald G
2006-03-01
In 2000, the Centers for Medicare & Medicaid Services announced a plan to allow for enhanced reimbursement for office endoscopy. This change in reimbursement was phased in during three years. The purpose of this study was to evaluate the fiscal outcomes and quality measures in the first two and a one-half years of performing endoscopy in an office setting under the new Centers for Medicare & Medicaid Services guidelines. The following financial parameters were gathered: number of endoscopies, expenses (divided into salaries and operational), net revenue, and margin for endoscopies performed in the office compared with the hospital. All endoscopies were performed by endoscopists with advanced training (gastroenterology fellowship or colon and rectal surgery residency). Monitoring equipment included continuous SaO2 and automated blood pressure in all patients and continuous electrocardiographic monitors in selected patients. Quality/safety data have been tracked in a prospective manner and include number of transfers to the hospital, perforations, bleeding requiring transfusion or hospitalization, and cardiorespiratory arrest. The financial outcomes are as follows: 13,285 endoscopies performed from the opening of the unit through December 2003; net revenue per case $504 per case; expense per case has dropped from $205 per case to $145 per case; the overall financial benefit of performing endoscopy in the office compared with the hospital was an additional $28 to $143 per case depending on the insurance carrier. The quality outcomes since inception of the unit include the following: 13,285 endoscopies; 0 hospital transfers, 0 cardiorespiratory arrests; 0 perforations; and 1 bleeding episode that required hospitalization. Endoscopy performed in the office setting is safe when done with appropriate monitoring and in the proper patient population. At the time of this study, office endoscopy also is financially rewarding but changes in Centers for Medicare & Medicaid Services reimbursement threaten the ability to retain any financial benefit.
Manes, G; Mosca, S; Balzano, A; Amitrano, L; Bove, A; de Nucci, C; Guardascione, M A; Lombardi, G; Picascia, S; Riccio, E; Rocco, P V
2001-01-01
Aim of the present study is to assess, according to the guidelines of the Maastricht Consensus Conference, the appropriateness and diagnostic yield of upper gastrointestinal endoscopy in an open-access endoscopy system, in order to evaluate the diffusion of knowledge about Helicobacter pylori among different types of physicians. Patients undergoing endoscopy because of dyspeptic symptoms were prospectively considered in 21 endoscopy services of Campania during two different 1-week periods in 1998 and 2001. The following data were recorded: age, sex, symptoms, history of peptic ulcer with regard to previous endoscopic or radiographic examinations and treatment, endoscopic diagnosis, and H. pylori status. The indication for endoscopy was evaluated according to Maastricht guidelines and current medical knowledge. In the two periods, 1998 and 2001, 706 and 520 patients were, respectively, considered. The two series were matched for demographic characteristics, symptoms, and endoscopic diagnosis. Endoscopy was considered not indicated in 398 patients (56.4%) in 1998 and in 265 patients (50.9%) in 2001 (p = NS). The majority of them, 288/398 (72.3%) in 1998 and 162/265 (61.1%) in 2001 (p = 0.001), had recently undergone endoscopy or radiology and empiric antisecretory treatment or eradication. They had been referred to endoscopy because of recurrence of symptoms or to assess healing. In 110 cases in 1998 (27.6%) and in 103 cases in 2001 (38.9%; p = 0.001) endoscopy was performed in dyspeptic patients younger than 45 years without alarm symptoms. 4 years after the Maastricht Conference, a large number of endoscopic examinations are not indicated and could be avoided following the Maastricht guidelines. In 2001, in comparison to 1998, a larger number of physicians are likely to investigate and treat correctly the H.-pylori-related diseases, but there are still some problems with the application of the 'test-and-treat policy'. Copyright 2001 S. Karger AG, Basel
Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul
2016-02-01
The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision. ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients.
Cho, Yu Kyung
2016-07-01
In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.
Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.
Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S
2017-07-01
The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.
Training the gastrointestinal endoscopy trainer.
Waschke, Kevin A; Anderson, John; Macintosh, Donald; Valori, Roland M
2016-06-01
Endoscopy training has traditionally been accomplished by an informal process in the endoscopy unit that parallels apprenticeship training seen in other areas of professional education. Subsequent to an audit, a series of interventions were implemented in the English National Health Service to support both service delivery and to improve endoscopy training. The resulting training centers deliver a variety of hands-on endoscopy courses, established in parallel with the roll out of a colon cancer screening program that monitors and documents quality outcomes among endoscopists. The program developed a 'training the trainer' module that subsequently became known as the Training the Colonoscopy Trainer course (TCT). Several years after its implementation, colonoscopy quality outcomes in the UK have improved substantially. The core TCT program has spread to other countries with demonstration of a marked impact on endoscopy training and performance. The aim of this chapter is to describe the principles that underlie effective endoscopy training in this program using the TCT as an example. While the review focuses on the specific example of colonoscopy training, the approach is generic to the teaching of any technical skill; it has been successfully transferred to the teaching of laparoscopic surgery as well as other endoscopic techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.
Remote clinical assessment of gastrointestinal endoscopy (tele-endoscopy): an initial experience.
Kim, C. Y.; Etemad, B.; Glenn, T. F.; Mackey, H. A.; Viator, G. E.; Wallace, M. B.; Mokhashi, M. S.; Cotton, P. B.; Hawes, R. H.
2000-01-01
BACKGROUND: Gastrointestinal (GI) endoscopy is an effective tool to screen for cancers of the digestive tract. However, access to endoscopy is limited in many parts of South Carolina. This trial is a part of a prospective multi-part study for remote cancer screening in coastal South Carolina. This pilot study was to evaluate the quality of tele-endoscopy for cancer screening. METHODS: 10 patients scheduled for endoscopic procedures were observed simultaneously by the endoscopist and a remote observer connected over a 512 kbps ISDN line. Findings by both were compared for concordance on malignant or premalignant lesions. RESULTS: The image quality was adequate to support remote diagnosis of GI cancer and abnormal lesions by an experienced observer. However, assessment of the esophagogastric junction for Barrett's esophagus was equivocal. CONCLUSIONS: Overall, our tele-endoscopy setup shows great promise for remote supervision or observation of endoscopic procedures done by nurse endoscopists. Tele-endoscopy is both adequate and feasible for diagnosis of most gastrointestinal lesions. Subtle lesions still may be missed in our current setup. However, improvements are being made in our setup to address the problem with resolution prior to further evaluation. PMID:11079918
Objective image characterization of a spectral CT scanner with dual-layer detector
NASA Astrophysics Data System (ADS)
Ozguner, Orhan; Dhanantwari, Amar; Halliburton, Sandra; Wen, Gezheng; Utrup, Steven; Jordan, David
2018-01-01
This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital’s clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm-1. NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.
Cappell, Mitchell S
2012-01-01
These quotations, whether humorous or serious, provide insight into how gastroenterology nurses, gastroenterologists, and endoscopists feel about themselves as professionals, how other healthcare professionals perceive them, and their image in popular culture. Recognition of these aspects of gastroenterology nursing, gastroenterology, and endoscopy are important for self-improvement, correcting public misperceptions, and appreciating how patient misperceptions about gastroenterology nurses and gastroenterologists and patient attitudes toward endoscopy may present barriers that gastroenterology professionals must overcome to improve patient care. These quotations also fulfill a need for witticisms during dry endoscopy lectures!
[Expandable stents and composite prosthesis].
Baldeyrou, P
1999-11-01
Today, numerous expandable and mixed silicone metallic stents for trachea and bronchi are available. Among the many technical propositions, Nitinol is a new alloy with promising potential, offering the advantage of shape memory. The right stent is the one which best meets the needs of the individual stenotic situation as evaluated by endoscopy and CT. Sufficient experience has been acquired only with the Dumon stent, giving exact information about its qualities and possible complications. The new stents are thinner. Some can be inserted under fluoroscopic and fibroscopic control. They are presumed to produce fewer complications an provide answers to some still unresolved questions such as dyskinesia or stenosis on short bronchi. They appear to be more easily inserted on the tracheo-bronchial tree. More experience is needed to satisfactorily identify specific indications and contraindications. A prospective registry will be important to obtain comparative information more quickly.
Routes for virtually guided endoscopic liver resection of subdiaphragmatic liver tumors.
Aoki, Takeshi; Murakami, Masahiko; Fujimori, Akira; Koizumi, Tomotake; Enami, Yuta; Kusano, Tomokazu; Matsuda, Kazuhiro; Yamada, Kosuke; Nogaki, Koji; Wada, Yusuke; Hakozaki, Tomoki; Goto, Satoru; Watanabe, Makoto; Otsuka, Koji
2016-03-01
Laparoscopic and thoracoscopic/laparoscopic hepatectomy is a safe procedure that has potential advantages over open surgery. However, deeply positioned liver tumors require expert laparoscopic and thoracoscopic/laparoscopic hepatectomy techniques. Using simulated preoperative three-dimensional virtual endoscopy (P3DVE) guidance, we demonstrate herein that a thoracoscopic approach (TA), thoracoscopic-laparoscopic approach (TLA), and laparoscopic approach (LA) are all feasible and safe routes for performing pure laparoscopic and thoracoscopic/laparoscopic resection of liver tumors located in the 4a, 7, and 8 liver subdiaphragmatic areas. Thirty-eight patients underwent laparoscopic and thoracoscopic/laparoscopic partial liver resection (TA 13 cases, TLA two cases, and LA 23 cases) of the subdiaphragmatic area at Showa University Hospital. All surgical approaches were preoperatively determined based on preoperative 3D virtual endoscopic simulation (P3DVES) visualization and findings using the image processing software SYNAPSE VINCENT(®). Laparoscopic and thoracoscopic/laparoscopic liver resection was successfully performed for all cases under P3DVE instruction. The mean operative times using TA, TLA, and LA approaches were 193, 185, and 190 min, respectively. Mean blood loss during TA, TLA, and LA was 179, 138, and 73 g, respectively. No patients required conversion to open surgery, and there were no deaths, although there were three cases of Clavien-Dindo grade I in TA along with three cases of grade I and one case of grade II in LA. TA, TLA, and LA routes performed under P3DVE instruction are feasible and safe to perform for pure laparoscopic and thoracoscopic/laparoscopic liver resection in selected patients with lesions located in the hepatic subdiaphragmatic area.
Adaptive learning compressive tracking based on Markov location prediction
NASA Astrophysics Data System (ADS)
Zhou, Xingyu; Fu, Dongmei; Yang, Tao; Shi, Yanan
2017-03-01
Object tracking is an interdisciplinary research topic in image processing, pattern recognition, and computer vision which has theoretical and practical application value in video surveillance, virtual reality, and automatic navigation. Compressive tracking (CT) has many advantages, such as efficiency and accuracy. However, when there are object occlusion, abrupt motion and blur, similar objects, and scale changing, the CT has the problem of tracking drift. We propose the Markov object location prediction to get the initial position of the object. Then CT is used to locate the object accurately, and the classifier parameter adaptive updating strategy is given based on the confidence map. At the same time according to the object location, extract the scale features, which is able to deal with object scale variations effectively. Experimental results show that the proposed algorithm has better tracking accuracy and robustness than current advanced algorithms and achieves real-time performance.
Ethical aspects of capsule endoscopy.
Niv, Yaron
2008-01-01
Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.
Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E
2004-04-01
Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.
Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea
Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck
2016-01-01
Background/Aims: The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. Methods: We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Results: Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R2=0.340, p<0.001). Conclusions: An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit. PMID:26898513
Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea.
Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck
2016-05-01
The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R (2) =0.340, p<0.001). An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurz, C; LMU Munich, Munich; Park, Y
2016-06-15
Purpose: To enable adaptive intensity modulated proton therapy for sites sensitive to inter-fractional changes on the basis of accurate CBCT-based proton dose calculations. To this aim two CBCT intensity correction methods are considered: planning CT (pCT) to CBCT DIR and projection correction based on pCT DIR prior. Methods: 3 H&N and 3 prostate cancer patients with CBCT images and corresponding projections were used in this study, in addition to pCT and re-planning CT (rpCT) images (H&N only). A virtual CT (vCT) was generated by pCT to CBCT DIR. In a second approach, the vCT was used as prior for scattermore » correction of the CBCT projections to yield a CBCTcor image. BEV 2D range maps of SFUD IMPT plans were compared. For the prostate cases, the geometric accuracy of the vCT was also evaluated by contour comparison to physician delineation of the CBCTcor and original CBCT. Results: SFUD dose calculations on vCT and CBCTcor were found to be within 3mm for 97% to 99% of 2D range maps. Median range differences compared to rpCT were below 0.5mm. Analysis showed that the DIR-based vCT approach exhibits inaccuracies in the pelvic region due to the very low soft-tissue contrast in the CBCT. The CBCTcor approach yielded results closer to the original CBCT in terms of DICE coefficients than the vCT (median 0.91 vs 0.81) for targets and OARs. In general, the CBCTcor approach was less affected by inaccuracies of the DIR used during the generation of the vCT prior. Conclusion: Both techniques yield 3D CBCT images with intensities equivalent to diagnostic CT and appear suitable for IMPT dose calculation for most sites. For H&N cases, no considerable differences between the two techniques were found, while improved results of the CBCTcor were observed for pelvic cases due to the reduced sensitivity to registration inaccuracies. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)« less
Heiser, Clemens; Fthenakis, Phillippe; Hapfelmeier, Alexander; Berger, Sebastian; Hofauer, Benedikt; Hohenhorst, Winfried; Kochs, Eberhard F; Wagner, Klaus J; Edenharter, Guenther M
2017-09-01
Drug-induced sleep endoscopy (DISE) has become an important diagnostic examination tool in the treatment decision process for surgical therapies in the treatment of obstructive sleep apnea (OSA). Currently, there is a variety of regimes for the performance of DISE, which renders comparison and assessment across results difficult. It remains unclear how the different regimes influence the findings of the examination and the resulting conclusions and treatment recommendations. This study aimed to investigate the correlation between increasing levels of sedation (i.e., light, medium, and deep) induced by propofol using a target-controlled infusion (TCI) pump, with the obstruction patterns at the levels of the velum, oropharynx, tongue base, and epiglottis (i.e., VOTE classification). A second goal was the establishment of a sufficient sedation level to enable a reliable decision regarding treatment recommendations. Forty-three patients with OSA underwent a DISE procedure using propofol TCI. Three levels of sedation were defined, depending on entropy levels and assessment of sedation: light sedation, medium sedation, and deep sedation. The evaluation of the upper airway at each level, with increasing sedation, was documented using the VOTE classification. The elapsed time at which each assessment was performed was recorded. Upper airway changes occurred and were measured throughout the DISE procedure. Clinically useful determinations of airway closure occurred at medium sedation; this level of sedation was most probably achieved with a blood propofol concentration of 3.2 μg/ml. In all 43 patients, definite treatment decisions could be made at medium sedation level. Increasing sedation did not result in changes in the treatment decision. Changes in upper airway collapse during DISE with propofol TCI occur at levels of medium sedation. Decisions regarding surgical treatment could be made at this level of sedation. Upper Airway Collapse in Patients with Obstructive Sleep Apnea Syndrome by Drug Induced Sleep Endoscopy (URL: https://clinicaltrials.gov/ct2/results?term=NCT02588300&Search=Search ) REGISTRATION NUMBER: NCT02588300.
Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra
2016-11-15
Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.
Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul
2016-01-01
The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision.ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients. © Georg Thieme Verlag KG Stuttgart · New York.
Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers
Ro, Tae H; Mathew, Michelle A; Misra, Subhasis
2015-01-01
Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology. PMID:26361416
Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises
2016-05-01
Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Sebastián Domingo, Juan José; Sánchez Sánchez, Clara; Galve Royo, Eugenio; Mendi Metola, Carolina; Valdepérez Torrubia, Javier
2012-02-01
To create an improvement team within a healthcare quality improvement project of the Government of Aragon (Spain), aimed at increasing the quality of care and suitability of the indications of gastrointestinal endoscopy in the open access endoscopy system of a secondary hospital in Aragon. The team developed a consensus document indicating how to use oral endoscopy and colonoscopy correctly, and held information and training sessions with all the primary care physicians involved in this area. Sector I health centers and Royo Villanova Hospital, in Zaragoza. The team consisted of a gastroenterologist and three primary care physicians and, from the outset received the support of the primary care administration and management in the health area. Inappropriate use of endoscopy, particularly colonoscopy, was reduced from 20% to 11.6%. Significant savings were achieved in health costs. The endoscopy waiting list was reduced. The quality of care and the safety of patients undergoing these examinations improved. Training of primary care physicians in these procedures was enhanced, and coordination between primary and specialized was implemented. To ensure efficient running of an open access gastrointestinal endoscopy system, an interdisciplinary improvement team and the full involvement of the primary care staff managing this resource are required. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.
Ro, Tae H; Mathew, Michelle A; Misra, Subhasis
2015-09-07
Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology.
Hickethier, Tilman; Iuga, Andra-Iza; Lennartz, Simon; Hauger, Myriam; Byrtus, Jonathan; Luetkens, Julian A; Haneder, Stefan; Maintz, David; Doerner, Jonas
We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.
Thali, Michael J; Taubenreuther, Ulrike; Karolczak, Marek; Braun, Marcel; Brueschweiler, Walter; Kalender, Willi A; Dirnhofer, Richard
2003-11-01
When a knife is stabbed in bone, it leaves an impression in the bone. The characteristics (shape, size, etc.) may indicate the type of tool used to produce the patterned injury in bone. Until now it has been impossible in forensic sciences to document such damage precisely and non-destructively. Micro-computed tomography (Micro-CT) offers an opportunity to analyze patterned injuries of tool marks made in bone. Using high-resolution Micro-CT and computer software, detailed analysis of three-dimensional (3D) architecture has recently become feasible and allows microstructural 3D bone information to be collected. With adequate viewing software, data from 2D slice of an arbitrary plane can be extracted from 3D datasets. Using such software as a "digital virtual knife," the examiner can interactively section and analyze the 3D sample. Analysis of the bone injury revealed that Micro-CT provides an opportunity to correlate a bone injury to an injury-causing instrument. Even broken knife tips can be graphically and non-destructively assigned to a suspect weapon.
The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery.
Valdés Olmos, R A; Vidal-Sicart, S; Giammarile, F; Zaknun, J J; Van Leeuwen, F W; Mariani, G
2014-06-01
The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In these protocols the generated virtual SPECT/CT elements are visually superimposed in the body of the patient in the operating room to directly facilitate, by means of visualization on screen or using head-mounted devices, the localization of radioactive and/or fluorescent targets by minimal invasive approaches in areas of complex anatomy. All these technological advances will play an increasing role in the future extension and the clinical impact of the GOSTT concept.
SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Binzel, K; Hall, NC
Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less
Monte Carlo modeling of light propagation in the human head for applications in sinus imaging
NASA Astrophysics Data System (ADS)
Cerussi, Albert E.; Mishra, Nikhil; You, Joon; Bhandarkar, Naveen; Wong, Brian J. F.
2015-02-01
Sinus blockages are a common reason for physician visits, affecting 1 out of 7 in the United States. Over 20 million cases of acute bacterial sinusitis become chronic and require medical treatment. Diagnosis in the primary care setting is challenging because symptom criteria (via detailed clinical history) plus objective imaging (CT or endoscopy) is recommended. Unfortunately, neither option is routinely available in primary care. Our previous work demonstrated that low-cost near infrared (NIR) transillumination instruments produced signals that correlated with the bulk findings of sinus opacity measured by CT. We have upgraded the technology, but questions remain such as finding the optimal arrangement of light sources, measuring the influence of specific anatomical structures, and determining detection limits. In order to begin addressing these questions, we have modeled NIR light propagation inside the adult human head using a mesh-based Monte Carlo algorithm (MMCLab) applied to a detailed anatomical head model constructed from CT images. In this application the sinus itself, which under healthy conditions is a void region (e.g., non-scattering), is the region of interest instead of an obstacle to other contrast mechanisms. We report preliminary simulations that characterize the changes in detected intensity due to clear (i.e., healthy) versus blocked sinuses. We also ran simulations for two of our clinical cases and compared results with the measurements. The simulations presented herein serve as a proof of concept that this approach could be used to understand contrast mechanisms and limitations of NIR imaging of the sinus cavities.
NASA Astrophysics Data System (ADS)
Jelvehgaran, Pouya; Alderliesten, Tanja; Weda, Jelmer J. A.; de Bruin, Daniel M.; Faber, Dirk J.; Hulshof, Maarten C. C. M.; van Leeuwen, Ton G.; van Herk, Marcel B.; de Boer, Johannes F.
2017-03-01
Radiation therapy (RT) is used in operable and inoperable esophageal cancer patients. Endoscopic ultrasound-guided fiducial marker placement allows improved translation of the disease extent on endoscopy to computed tomography (CT) images used for RT planning and enables image-guided RT. However, microscopic tumor extent at the time of RT planning is unknown. Endoscopic optical coherence tomography (OCT) is a high-resolution (10-30µm) imaging modality with the potential for accurately determining the longitudinal disease extent. Visibility of fiducial markers on OCT is crucial for integrating OCT findings with the RT planning CT. We investigated the visibility on OCT (NinePoint Medical, Inc.) of 13 commercially available solid (Visicoil, Gold Anchor, Flexicoil, Polymark, and QLRAD) and liquid (BioXmark, Lipiodol, and Hydrogel) fiducial markers of different diameter. We designed and manufactured a set of dedicated Silicone-based esophageal phantoms to perform imaging in a controlled environment. The esophageal phantoms consist of several layers with different TiO2 concentrations to simulate the scattering properties of a typical healthy human esophagus. Markers were placed at various depths (0.5, 1.1, 2.0, and 3.0mm). OCT imaging allowed detection of all fiducial markers and phantom layers. The signal to background ratio was 6-fold higher for the solid fiducial markers than the liquid fiducial markers, yet OCT was capable of visualizing all 13 fiducial markers at all investigated depths. We conclude that RT fiducial markers can be visualized with OCT. This allows integration of OCT findings with CT for image-guided RT.
Noto, Benjamin; Auf der Springe, Katharina; Huss, Sebastian; Allkemper, Thomas; Stegger, Lars
2018-06-01
Ga-PSMA-11 PET/CT was performed in a 74-year-old man because of biochemical recurrence of prostate cancer following radiation therapy of the prostate gland 24 months earlier. Besides focal nuclide accumulation in the prostate gland suggestive of local recurrence, PET scan revealed no further pathologic uptake. However, CT showed multiple pulmonic nodules suggestive of metastases. Thoracotomy and pathologic examination revealed the nodules to be prostate cancer metastasis. Furthermore, immunohistochemical staining with PSMA antibodies demonstrated a virtual lack of PSMA expression. This case demonstrates the possibility of PSMA-negative metastases of prostate cancer an important pitfall that should be known to physicians interpreting PSMA PET.
Dimbwadyo-Terrer, I; Gil-Agudo, A; Segura-Fragoso, A; de los Reyes-Guzmán, A; Trincado-Alonso, F; Piazza, S; Polonio-López, B
2016-01-01
The aim of this study was to investigate the effects of a virtual reality program combined with conventional therapy in upper limb function in people with tetraplegia and to provide data about patients' satisfaction with the virtual reality system. Thirty-one people with subacute complete cervical tetraplegia participated in the study. Experimental group received 15 sessions with Toyra(®) virtual reality system for 5 weeks, 30 minutes/day, 3 days/week in addition to conventional therapy, while control group only received conventional therapy. All patients were assessed at baseline, after intervention, and at three-month follow-up with a battery of clinical, functional, and satisfaction scales. Control group showed significant improvements in the manual muscle test (p = 0,043, partial η (2) = 0,22) in the follow-up evaluation. Both groups demonstrated clinical, but nonsignificant, changes to their arm function in 4 of the 5 scales used. All patients showed a high level of satisfaction with the virtual reality system. This study showed that virtual reality added to conventional therapy produces similar results in upper limb function compared to only conventional therapy. Moreover, the gaming aspects incorporated in conventional rehabilitation appear to produce high motivation during execution of the assigned tasks. This trial is registered with EudraCT number 2015-002157-35.
Dimbwadyo-Terrer, I.; Gil-Agudo, A.; Segura-Fragoso, A.; de los Reyes-Guzmán, A.; Trincado-Alonso, F.; Piazza, S.; Polonio-López, B.
2016-01-01
The aim of this study was to investigate the effects of a virtual reality program combined with conventional therapy in upper limb function in people with tetraplegia and to provide data about patients' satisfaction with the virtual reality system. Thirty-one people with subacute complete cervical tetraplegia participated in the study. Experimental group received 15 sessions with Toyra® virtual reality system for 5 weeks, 30 minutes/day, 3 days/week in addition to conventional therapy, while control group only received conventional therapy. All patients were assessed at baseline, after intervention, and at three-month follow-up with a battery of clinical, functional, and satisfaction scales. Control group showed significant improvements in the manual muscle test (p = 0,043, partial η 2 = 0,22) in the follow-up evaluation. Both groups demonstrated clinical, but nonsignificant, changes to their arm function in 4 of the 5 scales used. All patients showed a high level of satisfaction with the virtual reality system. This study showed that virtual reality added to conventional therapy produces similar results in upper limb function compared to only conventional therapy. Moreover, the gaming aspects incorporated in conventional rehabilitation appear to produce high motivation during execution of the assigned tasks. This trial is registered with EudraCT number 2015-002157-35. PMID:26885511
Wide coverage by volume CT: benefits for cardiac imaging
NASA Astrophysics Data System (ADS)
Sablayrolles, Jean-Louis; Cesmeli, Erdogan; Mintandjian, Laura; Adda, Olivier; Dessalles-Martin, Diane
2005-04-01
With the development of new technologies, computed tomography (CT) is becoming a strong candidate for non-invasive imaging based tool for cardiac disease assessment. One of the challenges of cardiac CT is that a typical scan involves a breath hold period consisting of several heartbeats, about 20 sec with scanners having a longitudinal coverage of 2 cm, and causing the image quality (IQ) to be negatively impacted since beat to beat variation is high likely to occur without any medication, e.g. beta blockers. Because of this and the preference for shorter breath hold durations, a CT scanner with a wide coverage without the compromise in the spatial and temporal resolution of great clinical value. In this study, we aimed at determining the optimum scan duration and the delay relative to beginning of breath hold, to achieve high IQ. We acquired EKG data from 91 consecutive patients (77 M, 14 F; Age: 57 +/- 14) undergoing cardiac CT exams with contrast, performed on LightSpeed 16 and LightSpeed Pro16. As an IQ metric, we adopted the standard deviation of "beat-to-beat variation" (stdBBV) within a virtual scan period. Two radiologists evaluated images by assigning a score of 1 (worst) to 4 best). We validated stdBBV with the radiologist scores, which resulted in a population distribution of 9.5, 9.5, 31, and 50% for the score groups 1, 2, 3, and 4, respectively. Based on the scores, we defined a threshold for stdBBV and identified an optimum combination of virtual scan period and a delay. With the assumption that the relationship between the stdBBV and diagnosable scan IQ holds, our analysis suggested that the success rate can be improved to 100% with scan durations equal or less than 5 sec with a delay of 1 - 2 sec. We confirmed the suggested conclusion with LightSpeed VCT (GE Healthcare Technologies, Waukesha, WI), which has a wide longitudinal coverage, fine isotropic spatial resolution, and high temporal resolution, e.g. 40 mm coverage per rotation of 0.35 sec. Under the light of this study, LightSpeed VCT lends itself to be a clinically tested unique platform to achieve routine cardiac imaging.
Patient‐specific CT dosimetry calculation: a feasibility study
Xie, Huchen; Cheng, Jason Y.; Ning, Holly; Zhuge, Ying; Miller, Robert W.
2011-01-01
Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of “standard man”. Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient‐specific CT dosimetry. A radiation treatment planning system was modified to calculate patient‐specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose‐volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi‐empirical, measured correction‐based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point‐by‐point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%–20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient‐specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation. PACS numbers: 87.55.D‐, 87.57.Q‐, 87.53.Bn, 87.55.K‐ PMID:22089016
Patel, S G; Keswani, R; Elta, G; Saini, S; Menard-Katcher, P; Del Valle, J; Hosford, L; Myers, A; Ahnen, D; Schoenfeld, P; Wani, S
2015-07-01
The Accreditation Council for Graduate Medical Education (ACGME) emphasizes the importance of medical trainees meeting specific performance benchmarks and demonstrating readiness for unsupervised practice. The aim of this study was to examine the readiness of Gastroenterology (GI) fellowship programs for competency-based evaluation in endoscopic procedural training. ACGME-accredited GI program directors (PDs) and GI trainees nationwide completed an online survey of domains relevant to endoscopy training and competency assessment. Participants were queried about current methods and perceived quality of endoscopy training and assessment of competence. Participants were also queried about factors deemed important in endoscopy competence assessment. Five-point Likert items were analyzed as continuous variables by an independent t-test and χ(2)-test was used for comparison of proportions. Survey response rate was 64% (94/148) for PDs and 47% (546/1,167) for trainees. Twenty-three percent of surveyed PDs reported that they do not have a formal endoscopy curriculum. PDs placed less importance (1—very important to 5—very unimportant) on endoscopy volume (1.57 vs. 1.18, P<0.001), adenoma detection rate (2.00 vs. 1.53, P<0.001), and withdrawal times (1.96 vs. 1.68, P=0.009) in determining endoscopy competence compared with trainees. A majority of PDs report that competence is assessed by procedure volume (85%) and teaching attending evaluations (96%). Only a minority of programs use skills assessment tools (30%) or specific quality metrics (28%). Specific competencies are mostly assessed by individual teaching attending feedback as opposed to official documentation or feedback from a PD. PDs rate the overall quality of their endoscopy training and assessment of competence as better than overall ratings by trainees. Although the majority of PDs and trainees nationwide believe that measuring specific metrics is important in determining endoscopy competence, most programs still rely on procedure volume and subjective attending evaluations to determine overall competence. As medical training transitions from an apprenticeship model to competency-based education, there is a need for improved endoscopy curricula which are better suited to demonstrate readiness for unsupervised practice.
The role of a nurse telephone call to prevent no-shows in endoscopy.
Childers, Ryan E; Laird, Amy; Newman, Lisa; Keyashian, Kian
2016-12-01
Preventing missed appointments, or "no-shows," is an important target in improving efficient patient care and lowering costs in gastrointestinal endoscopy practices. We aimed to investigate whether a nurse telephone call would reduce no-show rates for endoscopic appointments, and to determine if hiring and maintaining a nurse dedicated to pre-endoscopy phone calls is economically advantageous. Our secondary aim was to identify predictors of no-shows to endoscopy appointments. We hired and trained a full-time licensed nurse to make a telephone call to patients 7 days before their scheduled upper endoscopy or colonoscopy. We compared this intervention with a previous reminder system involving mailed reminders. The effect of the intervention and impact of other predictors of no-shows were analyzed in 2 similar preintervention and postintervention patient cohorts. A mixed effects logistic regression model was used to estimate the association of the odds of being a no-show to the scheduled appointment and the characteristics of the patient and visit. An analysis of costs was performed that included the startup and maintenance costs of the intervention. We found that a nurse phone call was associated with a 33% reduction in the odds of a no-show visit (odds ratio, 0.67; 95% confidence interval, 0.50-0.91), adjusting for gender, age, partnered status, insurer type, distance from the endoscopy center, and visit type. The recovered reimbursement during the study period was $48,765, with net savings of $16,190 when accounting for the maintenance costs of the intervention; this resulted in a net revenue per annum of $43,173. We found that endoscopy practices may increase revenue, improve scheduling efficiency, and maximize resource utilization by hiring a nurse to reduce no-shows. Predictors of no-shows to endoscopy included unpartnered or single patients, commercial or managed care, being scheduled for colonoscopy as opposed to upper endoscopy, and being scheduled for a screening or surveillance colonoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain
2014-03-01
Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.
Contact Endoscopy of mucosal lesions of oral cavity – Preliminary experience
Mishra, Awadhesh Kumar; Nilakantan, Ajith; Sahai, Kavita; Datta, Rakesh; Malik, Ajay
2014-01-01
Background Contact Endoscopy is a non invasive tool to visualise alterations in cell architecture in vivo. In this study we investigated the diagnostic accuracy of Contact Endoscopy in detecting malignancy in oral mucosal lesions. Methods 76 patients with oral mucosal lesions requiring biopsy were included. Contact Endoscopy was performed by Otolaryngologist before biopsy and findings recorded. The lesion was then biopsied and sent for histopathological examination by Pathologist who was blinded to Contact Endoscopy findings. Findings of Contact Endoscopy were compared with histopathological findings taking the latter as the gold standard. Two biopsies were reported as ‘inconclusive’ on histopathological examination and hence excluded from the final analysis. Data of the remaining 74 patients is presented here. Results Clinically lesions were diagnosed as ulcero-proliferative lesions in 34 patients, Leukoplakia in 19, Erythroplakia in 9, Lichen planus in 5 and Submucous fibrosis in 7 patients. Histopathological examination revealed presence of malignancy in 97.06% of ulcero-proliferative mucosal lesions, 10.53% of leukoplakia and 33.33% of erythroplakia while corresponding figures on Contact Endoscopy were 94.12%, 5.26% and 11.11% respectively. No malignancy was detected in lichen planus and submucous fibrosis by either technique. When compared with histopathological examination, CE showed sensitivity of 84.21%, specificity of 94.44% and accuracy of 89.19%. No adverse effects on the patients were seen due to the procedure or stain. Conclusion Contact Endoscopy may be useful in determining cellular structure in vivo without biopsy to detect oral malignancy early. Further studies are suggested. PMID:25378780
Chen, Alexander; Pastis, Nicholas; Furukawa, Brian; Silvestri, Gerard A
2015-05-01
Electromagnetic navigation has improved the diagnostic yield of peripheral bronchoscopy for pulmonary nodules. For these procedures, a thin-slice chest CT scan is performed prior to bronchoscopy at full inspiration and is used to create virtual airway reconstructions that are used as a map during bronchoscopy. Movement of the lung occurs with respiratory variation during bronchoscopy, and the location of pulmonary nodules during procedures may differ significantly from their location on the initial planning full-inspiratory chest CT scan. This study was performed to quantify pulmonary nodule movement from full inspiration to end-exhalation during tidal volume breathing in patients undergoing electromagnetic navigation procedures. A retrospective review of electromagnetic navigation procedures was performed for which two preprocedure CT scans were performed prior to bronchoscopy. One CT scan was performed at full inspiration, and a second CT scan was performed at end-exhalation during tidal volume breathing. Pulmonary lesions were identified on both CT scans, and distances between positions were recorded. Eighty-five pulmonary lesions were identified in 46 patients. Average motion of all pulmonary lesions was 17.6 mm. Pulmonary lesions located in the lower lobes moved significantly more than upper lobe nodules. Size and distance from the pleura did not significantly impact movement. Significant movement of pulmonary lesions occurs between full inspiration and end-exhalation during tidal volume breathing. This movement from full inspiration on planning chest CT scan to tidal volume breathing during bronchoscopy may significantly affect the diagnostic yield of electromagnetic navigation bronchoscopy procedures.
In vivo differentiation of complementary contrast media at dual-energy CT.
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F; Gao, Dong-Wei; Yeh, Benjamin M
2012-10-01
To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase-enhanced CT scan simultaneously in a single examination. Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012.
In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei
2012-01-01
Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447
Hashimoto, Daniel A; Gomez, Ernest D; Beyer-Berjot, Laura; Khajuria, Ankur; Williams, Noel N; Darzi, Ara; Aggarwal, Rajesh
2015-01-01
Serious games have demonstrated efficacy in improving participation in surgical training activities, but studies have not yet demonstrated the effect of serious gaming on performance. This study investigated whether competitive training (CT) affects laparoscopic surgical performance. A total of 20 novices were recruited, and 18 (2 dropouts) were randomized into control or CT groups to perform 10 virtual reality laparoscopic cholecystectomies (LCs). Competitiveness of each participant was assessed. The CT group members were informed they were competing to outperform one another for a prize; performance ranking was shown before each session. The control group did not compete. Performance was assessed on time, movements, and instrument path length. Quality of performance was assessed with a global rating scale score. There were no significant intergroup differences in baseline skill or measured competitiveness. Time and global rating scale score, at final LC, were not significantly different between groups; however, the CT group was significantly more dexterous than control and had significantly lower variance in number of movements and instrument path length at the final LC (p = 0.019). Contentiousness was inversely related to time in the CT group. This was the first randomized controlled trial to investigate if CT can enhance performance in laparoscopic surgery. CT may lead to improved dexterity in laparoscopic surgery but yields otherwise similar performance to that of standard training in novices. Competition may have different effects on novices vs experienced surgeons, and subsequent research should investigate CT in experienced surgeons as well. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Schwaitzberg, Steven D; Dorozhkin, Denis; Sankaranarayanan, Ganesh; Matthes, Kai; Jones, Daniel B; De, Suvranu
2016-01-01
A virtual translumenal endoscopic surgical trainer (VTEST) is being developed to accelerate the development of natural orifice translumenal endoscopic surgery (NOTES) procedures and devices in a safe and risk-free environment. For a rapidly developing field such as NOTES, a needs analysis must be conducted regularly to discover emerging research trends and areas of potential high impact for a virtual simulator. This paper presents a survey-based study which follows a similar study conducted by this group in 2011 (Sankaranarayanan et al. in Surg Endosc 27:1607-1616, 2013). A 32-point questionnaire was distributed at the 2012 Natural Orifice Surgery Consortium for Assessment and Research annual meeting. These data were subsequently augmented by an identical online survey, targeted at the members of the American Society for Gastrointestinal Endoscopy and the Society of American Gastrointestinal and Endoscopic Surgeons, and analyzed. Twenty-eight NOTES experts participated in the 2012 study. Cholecystectomy (CE) procedure remained the most commonly performed NOTES technique, with 18 positive responses (64%). In contrast to 2011, the popularity of the NOTES appendectomy (AE) was significantly lower, with only 2 (7%) instances (CE vs. AE, p < 0.001), while the number of peroral endoscopic myotomy (POEM, PE) cases had increased significantly, with 11 (39%) positive responses, respectively (PE vs. AE, p = 0.013). Strong preference toward hybrid rather than pure NOTES techniques (82 vs. 11%, p < 0.001) was also expressed. Other responses were similar to those in the 2011 study, with the VTEST™ utility in developing and testing new techniques and instruments ranked particularly high. Based on the results of this study, a decision was made to focus exclusively on the transvaginal hybrid NOTES cholecystectomy procedure, including both rigid and flexible scope techniques. The importance of developing a virtual NOTES simulator was reaffirmed, with POEM identified as a promising candidate for future simulator development.
Modeling the convergence accommodation of stereo vision for binocular endoscopy.
Gao, Yuanqian; Li, Jinhua; Li, Jianmin; Wang, Shuxin
2018-02-01
The stereo laparoscope is an important tool for achieving depth perception in robot-assisted minimally invasive surgery (MIS). A dynamic convergence accommodation algorithm is proposed to improve the viewing experience and achieve accurate depth perception. Based on the principle of the human vision system, a positional kinematic model of the binocular view system is established. The imaging plane pair is rectified to ensure that the two rectified virtual optical axes intersect at the fixation target to provide immersive depth perception. Stereo disparity was simulated with the roll and pitch movements of the binocular system. The chessboard test and the endoscopic peg transfer task were performed, and the results demonstrated the improved disparity distribution and robustness of the proposed convergence accommodation method with respect to the position of the fixation target. This method offers a new solution for effective depth perception with the stereo laparoscopes used in robot-assisted MIS. Copyright © 2017 John Wiley & Sons, Ltd.
Gee, Carole T
2013-11-01
As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction.
Computer-based System for the Virtual-Endoscopic Guidance of Bronchoscopy.
Helferty, J P; Sherbondy, A J; Kiraly, A P; Higgins, W E
2007-11-01
The standard procedure for diagnosing lung cancer involves two stages: three-dimensional (3D) computed-tomography (CT) image assessment, followed by interventional bronchoscopy. In general, the physician has no link between the 3D CT image assessment results and the follow-on bronchoscopy. Thus, the physician essentially performs bronchoscopic biopsy of suspect cancer sites blindly. We have devised a computer-based system that greatly augments the physician's vision during bronchoscopy. The system uses techniques from computer graphics and computer vision to enable detailed 3D CT procedure planning and follow-on image-guided bronchoscopy. The procedure plan is directly linked to the bronchoscope procedure, through a live registration and fusion of the 3D CT data and bronchoscopic video. During a procedure, the system provides many visual tools, fused CT-video data, and quantitative distance measures; this gives the physician considerable visual feedback on how to maneuver the bronchoscope and where to insert the biopsy needle. Central to the system is a CT-video registration technique, based on normalized mutual information. Several sets of results verify the efficacy of the registration technique. In addition, we present a series of test results for the complete system for phantoms, animals, and human lung-cancer patients. The results indicate that not only is the variation in skill level between different physicians greatly reduced by the system over the standard procedure, but that biopsy effectiveness increases.
Grandl, Susanne; Sztrókay-Gaul, Anikó; Mittone, Alberto; Gasilov, Sergey; Brun, Emmanuel; Bravin, Alberto; Mayr, Doris; Auweter, Sigrid D; Hellerhoff, Karin; Reiser, Maximilian; Coan, Paola
2016-01-01
Neoadjuvant chemotherapy is the state-of-the-art treatment in advanced breast cancer. A correct visualization of the post-therapeutic tumor size is of high prognostic relevance. X-ray phase-contrast computed tomography (PC-CT) has been shown to provide improved soft-tissue contrast at a resolution formerly restricted to histopathology, at low doses. This study aimed at assessing ex-vivo the potential use of PC-CT for visualizing the effects of neoadjuvant chemotherapy on breast carcinoma. The analysis was performed on two ex-vivo formalin-fixed mastectomy samples containing an invasive carcinoma removed from two patients treated with neoadjuvant chemotherapy. Images were matched with corresponding histological slices. The visibility of typical post-therapeutic tissue changes was assessed and compared to results obtained with conventional clinical imaging modalities. PC-CT depicted the different tissue types with an excellent correlation to histopathology. Post-therapeutic tissue changes were correctly visualized and the residual tumor mass could be detected. PC-CT outperformed clinical imaging modalities in the detection of chemotherapy-induced tissue alterations including post-therapeutic tumor size. PC-CT might become a unique diagnostic tool in the prediction of tumor response to neoadjuvant chemotherapy. PC-CT might be used to assist during histopathological diagnosis, offering a high-resolution and high-contrast virtual histological tool for the accurate delineation of tumor boundaries.
Cholera toxin expression by El Tor Vibrio cholerae in shallow culture growth conditions.
Cobaxin, Mayra; Martínez, Haydee; Ayala, Guadalupe; Holmgren, Jan; Sjöling, Asa; Sánchez, Joaquín
2014-01-01
Vibrio cholerae O1 classical, El Tor and O139 are the primary biotypes that cause epidemic cholera, and they also express cholera toxin (CT). Although classical V. cholerae produces CT in various settings, the El Tor and O139 strains require specific growth conditions for CT induction, such as the so-called AKI conditions, which consist of growth in static conditions followed by growth under aerobic shaking conditions. However, our group has demonstrated that CT production may also take place in shallow static cultures. How these type of cultures induce CT production has been unclear, but we now report that in shallow culture growth conditions, there is virtual depletion of dissolved oxygen after 2.5 h of growth. Concurrently, during the first three to 4 h, endogenous CO2 accumulates in the media and the pH decreases. These findings may explain CT expression at the molecular level because CT production relies on a regulatory cascade, in which the key regulator AphB may be activated by anaerobiosis and by low pH. AphB activation stimulates TcpP synthesis, which induces ToxT production, and ToxT directly stimulates ctxAB expression, which encodes CT. Importantly, ToxT activity is enhanced by bicarbonate. Therefore, we suggest that in shallow cultures, AphB is activated by initial decreases in oxygen and pH, and subsequently, ToxT is activated by intracellular bicarbonate that has been generated from endogenous CO2. This working model would explain CT production in shallow cultures and, possibly, also in other growth conditions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Evaluation of the radiation doses in newborn patients submitted to CT examinations
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Souza Santos, William; Caldas, Linda V.E.; Belinato, Walmir
The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objectivemore » of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)« less
Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya
2016-01-01
AIM: To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). METHODS: In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. RESULTS: Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. CONCLUSION: Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH. PMID:27076770
Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya
2016-04-14
To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH.
Virtual reality case-specific rehearsal in temporal bone surgery: a preliminary evaluation.
Arora, Asit; Swords, Chloe; Khemani, Sam; Awad, Zaid; Darzi, Ara; Singh, Arvind; Tolley, Neil
2014-01-01
1. To investigate the feasibility of performing case-specific surgical rehearsal using a virtual reality temporal bone simulator. 2. To identify potential clinical applications in temporal bone surgery. Prospective assessment study. St Mary's Hospital, Imperial College NHS Trust, London UK. Sixteen participants consisting of a trainer and trainee group. Twenty-four cadaver temporal bones were CT-scanned and uploaded onto the Voxelman simulator. Sixteen participants performed a 90-min temporal bone dissection on the generic simulation model followed by 3 dissection tasks on the case simulation and cadaver models. Case rehearsal was assessed for feasibility. Clinical applications and usefulness were evaluated using a 5-point Likert-type scale. The upload process required a semi-automated system. Average time for upload was 20 min. Suboptimal reconstruction occurred in 21% of cases arising when the mastoid process and ossicular chain were not captured (n = 2) or when artefact was generated (n = 3). Case rehearsal rated highly (Likert score >4) for confidence (75%), facilitating planning (75%) and training (94%). Potential clinical applications for case rehearsal include ossicular chain surgery, cochlear implantation and congenital anomalies. Case rehearsal of cholesteatoma surgery is not possible on the current platform due to suboptimal soft tissue representation. The process of uploading CT data onto a virtual reality temporal bone simulator to perform surgical rehearsal is feasible using a semi-automated system. Further clinical evaluation is warranted to assess the benefit of performing patient-specific surgical rehearsal in selected procedures. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Dwisaptarini, A P; Suebnukarn, S; Rhienmora, P; Haddawy, P; Koontongkaew, S
This work presents the multilayered caries model with a visuo-tactile virtual reality simulator and a randomized controlled trial protocol to determine the effectiveness of the simulator in training for minimally invasive caries removal. A three-dimensional, multilayered caries model was reconstructed from 10 micro-computed tomography (CT) images of deeply carious extracted human teeth before and after caries removal. The full grey scale 0-255 yielded a median grey scale value of 0-9, 10-18, 19-25, 26-52, and 53-80 regarding dental pulp, infected carious dentin, affected carious dentin, normal dentin, and normal enamel, respectively. The simulator was connected to two haptic devices for a handpiece and mouth mirror. The visuo-tactile feedback during the operation varied depending on the grey scale. Sixth-year dental students underwent a pretraining assessment of caries removal on extracted teeth. The students were then randomly assigned to train on either the simulator (n=16) or conventional extracted teeth (n=16) for 3 days, after which the assessment was repeated. The posttraining performance of caries removal improved compared with pretraining in both groups (Wilcoxon, p<0.05). The equivalence test for proportional differences (two 1-sided t-tests) with a 0.2 margin confirmed that the participants in both groups had identical posttraining performance scores (95% CI=0.92, 1; p=0.00). In conclusion, training on the micro-CT multilayered caries model with the visuo-tactile virtual reality simulator and conventional extracted tooth had equivalent effects on improving performance of minimally invasive caries removal.
Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J.; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng
2017-01-01
Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the “integrated image” on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications. PMID:28198442
Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng
2017-02-15
Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the "integrated image" on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications.
Import and visualization of clinical medical imagery into multiuser VR environments
NASA Astrophysics Data System (ADS)
Mehrle, Andreas H.; Freysinger, Wolfgang; Kikinis, Ron; Gunkel, Andreas; Kral, Florian
2005-03-01
The graphical representation of three-dimensional data obtained from tomographic imaging has been the central problem since this technology is available. Neither the representation as a set of two-dimensional slices nor the 2D projection of three-dimensional models yields satisfactory results. In this paper a way is outlined which permits the investigation of volumetric clinical data obtained from standard CT, MR, PET, SPECT or experimental very high resolution CT-scanners in a three dimensional environment within a few worksteps. Volumetric datasets are converted into surface data (segmentation process) using the 3D-Slicer software tool and saved as .vtk files and exported as a collection of primitives in any common file format (.iv, .pfb). Subsequently this files can be displayed and manipulated in the CAVE virtual reality center. The CAVE is a multiuser walkable virtual room consisting of several walls on which stereoscopic images are projected by rear panel beamers. Adequate tracking of the head position and separate image calculation for each eye yields a vivid impression for one or several users. With the use of a seperately tracked 6D joystick manipulations such as rotation, translation, zooming, decomposition or highlighting can be done intuitively. The usage of the CAVE technology opens new possibilities especially in surgical training ("hands-on-effect") and as an educational tool (availability of pathological data). Unlike concurring technologies the CAVE permits a walk-through into the virtual scene but preserves enough physical perception to allow interaction between multiple users, e.g. gestures and movements. By training in a virtual environment on one hand the learning process of students in complex anatomic findings may be improved considerably and on the other hand unaccustomed views such as the one through a microscope or endoscope can be trained in advance. The availability of low-cost PC based CAVE-like systems and the rapidly decreasing price of high-performance video beamers makes the CAVE an affordable alternative to conventional surgical training techniques and without limitations in handling cadavers.
Thomson, Mike; Tringali, Andrea; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf D; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro
2017-01-01
This guideline refers to infants, children, and adolescents ages 0 to 18 years. The areas covered include indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; corrosive ingestion and stricture/stenosis endoscopic management; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography; and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease has been dealt with in other guidelines and are therefore not mentioned in this guideline. Training and ongoing skill maintenance are to be dealt with in an imminent sister publication to this.
Colonic lesion characterization in inflammatory bowel disease: A systematic review and meta-analysis
Lord, Richard; Burr, Nicholas E; Mohammed, Noor; Subramanian, Venkataraman
2018-01-01
AIM To perform a systematic review and meta-analysis for the diagnostic accuracy of in vivo lesion characterization in colonic inflammatory bowel disease (IBD), using optical imaging techniques, including virtual chromoendoscopy (VCE), dye-based chromoendoscopy (DBC), magnification endoscopy and confocal laser endomicroscopy (CLE). METHODS We searched Medline, Embase and the Cochrane library. We performed a bivariate meta-analysis to calculate the pooled estimate sensitivities, specificities, positive and negative likelihood ratios (+LHR, -LHR), diagnostic odds ratios (DOR), and area under the SROC curve (AUSROC) for each technology group. A subgroup analysis was performed to investigate differences in real-time non-magnified Kudo pit patterns (with VCE and DBC) and real-time CLE. RESULTS We included 22 studies [1491 patients; 4674 polyps, of which 539 (11.5%) were neoplastic]. Real-time CLE had a pooled sensitivity of 91% (95%CI: 66%-98%), specificity of 97% (95%CI: 94%-98%), and an AUSROC of 0.98 (95%CI: 0.97-0.99). Magnification endoscopy had a pooled sensitivity of 90% (95%CI: 77%-96%) and specificity of 87% (95%CI: 81%-91%). VCE had a pooled sensitivity of 86% (95%CI: 62%-95%) and specificity of 87% (95%CI: 72%-95%). DBC had a pooled sensitivity of 67% (95%CI: 44%-84%) and specificity of 86% (95%CI: 72%-94%). CONCLUSION Real-time CLE is a highly accurate technology for differentiating neoplastic from non-neoplastic lesions in patients with colonic IBD. However, most CLE studies were performed by single expert users within tertiary centres, potentially confounding these results. PMID:29563760
NASA Astrophysics Data System (ADS)
Gong, Ren Hui; Jenkins, Brad; Sze, Raymond W.; Yaniv, Ziv
2014-03-01
The skills required for obtaining informative x-ray fluoroscopy images are currently acquired while trainees provide clinical care. As a consequence, trainees and patients are exposed to higher doses of radiation. Use of simulation has the potential to reduce this radiation exposure by enabling trainees to improve their skills in a safe environment prior to treating patients. We describe a low cost, high fidelity, fluoroscopy simulation system. Our system enables operators to practice their skills using the clinical device and simulated x-rays of a virtual patient. The patient is represented using a set of temporal Computed Tomography (CT) images, corresponding to the underlying dynamic processes. Simulated x-ray images, digitally reconstructed radiographs (DRRs), are generated from the CTs using ray-casting with customizable machine specific imaging parameters. To establish the spatial relationship between the CT and the fluoroscopy device, the CT is virtually attached to a patient phantom and a web camera is used to track the phantom's pose. The camera is mounted on the fluoroscope's intensifier and the relationship between it and the x-ray source is obtained via calibration. To control image acquisition the operator moves the fluoroscope as in normal operation mode. Control of zoom, collimation and image save is done using a keypad mounted alongside the device's control panel. Implementation is based on the Image-Guided Surgery Toolkit (IGSTK), and the use of the graphics processing unit (GPU) for accelerated image generation. Our system was evaluated by 11 clinicians and was found to be sufficiently realistic for training purposes.
Generating patient-specific pulmonary vascular models for surgical planning
NASA Astrophysics Data System (ADS)
Murff, Daniel; Co-Vu, Jennifer; O'Dell, Walter G.
2015-03-01
Each year in the U.S., 7.4 million surgical procedures involving the major vessels are performed. Many of our patients require multiple surgeries, and many of the procedures include "surgical exploration". Procedures of this kind come with a significant amount of risk, carrying up to a 17.4% predicted mortality rate. This is especially concerning for our target population of pediatric patients with congenital abnormalities of the heart and major pulmonary vessels. This paper offers a novel approach to surgical planning which includes studying virtual and physical models of pulmonary vasculature of an individual patient before operation obtained from conventional 3D X-ray computed tomography (CT) scans of the chest. These models would provide clinicians with a non-invasive, intricately detailed representation of patient anatomy, and could reduce the need for invasive planning procedures such as exploratory surgery. Researchers involved in the AirPROM project have already demonstrated the utility of virtual and physical models in treatment planning of the airways of the chest. Clinicians have acknowledged the potential benefit from such a technology. A method for creating patient-derived physical models is demonstrated on pulmonary vasculature extracted from a CT scan with contrast of an adult human. Using a modified version of the NIH ImageJ program, a series of image processing functions are used to extract and mathematically reconstruct the vasculature tree structures of interest. An auto-generated STL file is sent to a 3D printer to create a physical model of the major pulmonary vasculature generated from 3D CT scans of patients.
Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.
Loffeld, R J L F; Liberov, B; Dekkers, P E P
2015-07-01
The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p < 0.001), these two had the longest careers in endoscopy. The two younger endoscopists did significantly less often procedures in patients with anastomoses and because of surveillance (p < 0.001, respectively). One endoscopist detected significantly less colorectal cancers than the other three endoscopists (p < 0.001). This study presents the PDR in normal routine daily endoscopy practice. It can be concluded that the PDR, implicating the ADR, in unselected patients can be lower in individual endoscopists than recommended in the literature. This highly depends on the case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.
Endoscopy and General Surgery - Parts of the Same Activity.
Doran, Horia; Pătraşcu, Traian
2016-01-01
In general and digestive surgical departments, an accurate diagnosis and appropriate treatment of our patients require a wide and continuous access to endoscopy. As many surgical clinics have already developed their own endoscopy units, we plead for the future presence of at least 1 or 2 surgeons, board certified in endoscopy, in every surgical department. We have retrospectively analyzed the activity of the endoscopic unit as a part of the Surgical Clinic of "Dr. I. Cantacuzino" Clinical Hospital since 2007, when it was settled, and its benefits, regarding a higher accessibility for our patients and a reliable support for all the doctors. The number of procedures has increased constantly, from 137, performed by 2 surgeons in 2007 to 1546, in 2015, when 7 surgeons were able to get involved in endoscopic procedures, on a 24/7 schedule. The etiological diagnosis of gastrointestinal hemorrhages, the early detection of gastric, colonic and upper rectal tumors, the follow-up of oncologic patients are only a few of the fields in which endoscopy proved its benefits. Furthermore, surgeons have the practical training and the legal board certification for the approach and treatment of complications. An increased number of surgeons who have also board certification in endoscopy cannot be but very useful. The best way to accomplish this goal would be the inclusion of a digestive endoscopy module during the training program of all future general surgeons. Celsius.
Population of 224 realistic human subject-based computational breast phantoms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, David W.; Wells, Jered R., E-mail: jered.wells@duke.edu; Sturgeon, Gregory M.
Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was thenmore » applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns.« less
Population of 224 realistic human subject-based computational breast phantoms
Erickson, David W.; Wells, Jered R.; Sturgeon, Gregory M.; Dobbins, James T.; Segars, W. Paul; Lo, Joseph Y.
2016-01-01
Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns. PMID:26745896