Chromostereopsis in "virtual reality" adapters with electrically tuneable liquid lens oculars
NASA Astrophysics Data System (ADS)
Ozolinsh, Maris; Muizniece, Kristine; Berzinsh, Janis
2016-10-01
Chromostereopsis can be sight and feel in "Virtual Reality" adapters, that induces the appearance of color dependant depth sense and, finally, combines this sense with the source conceived depth scenario. Present studies are devoted to investigation the induced chromastereopsis when using adapted "Virtual Reality" frame together with mobile devices as smartphones. We did observation of composite visual stimuli presented on the high spatial resolution screen of the mobile phone placed inside a portable "Virtual Reality" adapter. Separated for the left and right eyes stimuli consisted of two areas: a) identical for both eyes color chromostereopsis part, and b) additional conventional color neutral random-dot stereopsis part with a stereodisparity based on the horizontal shift of a random-dot segment in images for the left and right eyes, correspondingly. The observer task was to equalize the depth sense for neutral and colored stimuli areas. Such scheme allows to determine actual observed chromostereopsis disparity value versus eye stimuli color difference. At standard observation conditions for adapter with +2D ocular lenses for mobile red-blue stimuli, the perceptual chromostereopsis depth sensitivity on color difference was linearly approximated with a slope SChS ≈ 2.1[arcmin/(Labcolor difference)] for red-blue pairs. Additional to standard application in adapter the tuneable "Varioptic" liquid lens oculars were incorporated, that allowed stimuli eye magnification, vergence and disparity values control electrically.
Isolated Norrie disease in a female caused by a balanced translocation t(X,6).
Meire, F M; Lafaut, B A; Speleman, F; Hanssens, M
1998-12-01
This is the second report of Norrie disease in a female patient with a de-novo balanced translocation t(X,6) with breakpoint at the location of the Norrie gene. At the age of 3 months, a girl was referred for suspected congenital glaucoma. The right eye was microphthalmic and ultrasonography was compatible with persistent hyperplasia of the primary vitreous. The left eye was also microphthalmic. The left cornea was larger than the right. The anterior chamber was virtual and leukocoria was evident. The eye felt hard digitally. Ultrasonography indicated an organized retinal detachment. The pathologic findings are reported and are compatible with Norrie disease.
Left Limb of North Pole of the Sun, March 20, 2007 (Anaglyph)
NASA Technical Reports Server (NTRS)
2007-01-01
[figure removed for brevity, see original site] [figure removed for brevity, see original site] Figure 1: Left eye view of a stereo pair Click on the image for full resolution TIFF Figure 2: Right eye view of a stereo pair Click on the image for full resolution TIFF Figure 1: This image was taken by the SECCHI Extreme UltraViolet Imager (EUVI) mounted on the STEREO-B spacecraft. STEREO-B is located behind the Earth, and follows the Earth in orbit around the Sun. This location enables us to view the Sun from the position of a virtual left eye in space. Figure 2: This image was taken by the SECCHI Extreme UltraViolet Imager (EUVI) mounted on the STEREO-A spacecraft. STEREO-A is located ahead of the Earth, and leads the Earth in orbit around the Sun, This location enables us to view the Sun from the position of a virtual right eye in space. NASA's Solar TErrestrial RElations Observatory (STEREO) satellites have provided the first three-dimensional images of the Sun. For the first time, scientists will be able to see structures in the Sun's atmosphere in three dimensions. The new view will greatly aid scientists' ability to understand solar physics and thereby improve space weather forecasting. This image is a composite of left and right eye color image pairs taken by the SECCHI Extreme UltraViolet Imager (EUVI) mounted on the STEREO-B and STEREO-A spacecraft. STEREO-B is located behind the Earth, and follows the Earth in orbit around the Sun, This location enables us to view the Sun from the position of a virtual left eye in space. STEREO-A is located ahead of the Earth, and leads the Earth in orbit around the Sun, This location enables us to view the Sun from the position of a virtual right eye in space. The EUVI imager is sensitive to wavelengths of light in the extreme ultraviolet portion of the spectrum. EUVI bands at wavelengths of 304, 171 and 195 Angstroms have been mapped to the red blue and green visible portion of the spectrum; and processed to emphasize the three-dimensional structure of the solar material. STEREO, a two-year mission, launched October 2006, will provide a unique and revolutionary view of the Sun-Earth System. The two nearly identical observatories -- one ahead of Earth in its orbit, the other trailing behind -- will trace the flow of energy and matter from the Sun to Earth. They will reveal the 3D structure of coronal mass ejections; violent eruptions of matter from the sun that can disrupt satellites and power grids, and help us understand why they happen. STEREO will become a key addition to the fleet of space weather detection satellites by providing more accurate alerts for the arrival time of Earth-directed solar ejections with its unique side-viewing perspective. STEREO is the third mission in NASA's Solar Terrestrial Probes program within NASA's Science Mission Directorate, Washington. The Goddard Science and Exploration Directorate manages the mission, instruments, and science center. The Johns Hopkins University Applied Physics Laboratory, Laurel, Md., designed and built the spacecraft and is responsible for mission operations. The imaging and particle detecting instruments were designed and built by scientific institutions in the U.S., UK, France, Germany, Belgium, Netherlands, and Switzerland. JPL is a division of the California Institute of Technology in Pasadena.The effects of task difficulty on visual search strategy in virtual 3D displays.
Pomplun, Marc; Garaas, Tyler W; Carrasco, Marisa
2013-08-28
Analyzing the factors that determine our choice of visual search strategy may shed light on visual behavior in everyday situations. Previous results suggest that increasing task difficulty leads to more systematic search paths. Here we analyze observers' eye movements in an "easy" conjunction search task and a "difficult" shape search task to study visual search strategies in stereoscopic search displays with virtual depth induced by binocular disparity. Standard eye-movement variables, such as fixation duration and initial saccade latency, as well as new measures proposed here, such as saccadic step size, relative saccadic selectivity, and x-y target distance, revealed systematic effects on search dynamics in the horizontal-vertical plane throughout the search process. We found that in the "easy" task, observers start with the processing of display items in the display center immediately after stimulus onset and subsequently move their gaze outwards, guided by extrafoveally perceived stimulus color. In contrast, the "difficult" task induced an initial gaze shift to the upper-left display corner, followed by a systematic left-right and top-down search process. The only consistent depth effect was a trend of initial saccades in the easy task with smallest displays to the items closest to the observer. The results demonstrate the utility of eye-movement analysis for understanding search strategies and provide a first step toward studying search strategies in actual 3D scenarios.
Astronauts Prepare for Mission With Virtual Reality Hardware
NASA Technical Reports Server (NTRS)
2001-01-01
Astronauts John M. Grunsfeld (left), STS-109 payload commander, and Nancy J. Currie, mission specialist, use the virtual reality lab at Johnson Space Center to train for upcoming duties aboard the Space Shuttle Columbia. This type of computer interface paired with virtual reality training hardware and software helps to prepare the entire team to perform its duties for the fourth Hubble Space Telescope Servicing mission. The most familiar form of virtual reality technology is some form of headpiece, which fits over your eyes and displays a three dimensional computerized image of another place. Turn your head left and right, and you see what would be to your sides; turn around, and you see what might be sneaking up on you. An important part of the technology is some type of data glove that you use to propel yourself through the virtual world. Currently, the medical community is using the new technologies in four major ways: To see parts of the body more accurately, for study, to make better diagnosis of disease and to plan surgery in more detail; to obtain a more accurate picture of a procedure during surgery; to perform more types of surgery with the most noninvasive, accurate methods possible; and to model interactions among molecules at a molecular level.
2001-08-08
Astronauts John M. Grunsfeld (left), STS-109 payload commander, and Nancy J. Currie, mission specialist, use the virtual reality lab at Johnson Space Center to train for upcoming duties aboard the Space Shuttle Columbia. This type of computer interface paired with virtual reality training hardware and software helps to prepare the entire team to perform its duties for the fourth Hubble Space Telescope Servicing mission. The most familiar form of virtual reality technology is some form of headpiece, which fits over your eyes and displays a three dimensional computerized image of another place. Turn your head left and right, and you see what would be to your sides; turn around, and you see what might be sneaking up on you. An important part of the technology is some type of data glove that you use to propel yourself through the virtual world. Currently, the medical community is using the new technologies in four major ways: To see parts of the body more accurately, for study, to make better diagnosis of disease and to plan surgery in more detail; to obtain a more accurate picture of a procedure during surgery; to perform more types of surgery with the most noninvasive, accurate methods possible; and to model interactions among molecules at a molecular level.
The effects of task difficulty on visual search strategy in virtual 3D displays
Pomplun, Marc; Garaas, Tyler W.; Carrasco, Marisa
2013-01-01
Analyzing the factors that determine our choice of visual search strategy may shed light on visual behavior in everyday situations. Previous results suggest that increasing task difficulty leads to more systematic search paths. Here we analyze observers' eye movements in an “easy” conjunction search task and a “difficult” shape search task to study visual search strategies in stereoscopic search displays with virtual depth induced by binocular disparity. Standard eye-movement variables, such as fixation duration and initial saccade latency, as well as new measures proposed here, such as saccadic step size, relative saccadic selectivity, and x−y target distance, revealed systematic effects on search dynamics in the horizontal-vertical plane throughout the search process. We found that in the “easy” task, observers start with the processing of display items in the display center immediately after stimulus onset and subsequently move their gaze outwards, guided by extrafoveally perceived stimulus color. In contrast, the “difficult” task induced an initial gaze shift to the upper-left display corner, followed by a systematic left-right and top-down search process. The only consistent depth effect was a trend of initial saccades in the easy task with smallest displays to the items closest to the observer. The results demonstrate the utility of eye-movement analysis for understanding search strategies and provide a first step toward studying search strategies in actual 3D scenarios. PMID:23986539
Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel Robert; Namer-Furstenberg, Rinat; Amedi, Amir
2014-01-01
Mobility training programs for helping the blind navigate through unknown places with a White-Cane significantly improve their mobility. However, what is the effect of new assistive technologies, offering more information to the blind user, on the underlying premises of these programs such as navigation patterns? We developed the virtual-EyeCane, a minimalistic sensory substitution device translating single-point-distance into auditory cues identical to the EyeCane's in the real world. We compared performance in virtual environments when using the virtual-EyeCane, a virtual-White-Cane, no device and visual navigation. We show that the characteristics of virtual-EyeCane navigation differ from navigation with a virtual-White-Cane or no device, and that virtual-EyeCane users complete more levels successfully, taking shorter paths and with less collisions than these groups, and we demonstrate the relative similarity of virtual-EyeCane and visual navigation patterns. This suggests that additional distance information indeed changes navigation patterns from virtual-White-Cane use, and brings them closer to visual navigation.
Multi-procedure management in an eyeglasses-related open globe injury
Skopiński, Piotr; Langwińska-Wośko, Ewa; Korwin, Magdalena; Kołodziejczyk, Wojciech; Ambroziak, Anna Maria
2014-01-01
We present a case of successful multi-procedure management of a patient with an open globe injury. A 47-year-old man sustained an injury to his left eye caused by glass fragments of his own spectacles shattered while he was protecting an unknown woman from physical assault at a bus stop. Over a span of 65 months the patient underwent multiple procedures including primary wound repair, penetrating keratoplasty combined with extracapsular cataract extraction, neodymium: YAG laser capsulotomy, and laser-assisted subepithelial keratectomy (LASEK), and had a successfully treated episode of corneal graft rejection. This sequence of treatment substantially improved his left eye vision from hand movements at the time of admission to 0.9–0.5 × 90 at the last follow-up nearly 10 years after the trauma. Proper initial surgical management of an open globe injury can create the possibility for virtually complete vision restoration. PMID:24729818
Yamaguchi, Shohei; Konishi, Kozo; Yasunaga, Takefumi; Yoshida, Daisuke; Kinjo, Nao; Kobayashi, Kiichiro; Ieiri, Satoshi; Okazaki, Ken; Nakashima, Hideaki; Tanoue, Kazuo; Maehara, Yoshihiko; Hashizume, Makoto
2007-12-01
This study was carried out to investigate whether eye-hand coordination skill on a virtual reality laparoscopic surgical simulator (the LAP Mentor) was able to differentiate among subjects with different laparoscopic experience and thus confirm its construct validity. A total of 31 surgeons, who were all right-handed, were divided into the following two groups according to their experience as an operator in laparoscopic surgery: experienced surgeons (more than 50 laparoscopic procedures) and novice surgeons (fewer than 10 laparoscopic procedures). The subjects were tested using the eye-hand coordination task of the LAP Mentor, and performance was compared between the two groups. Assessment of the laparoscopic skills was based on parameters measured by the simulator. The experienced surgeons completed the task significantly faster than the novice surgeons. The experienced surgeons also achieved a lower number of movements (NOM), better economy of movement (EOM) and faster average speed of the left instrument than the novice surgeons, whereas there were no significant differences between the two groups for the NOM, EOM and average speed of the right instrument. Eye-hand coordination skill of the nondominant hand, but not the dominant hand, measured using the LAP Mentor was able to differentiate between subjects with different laparoscopic experience. This study also provides evidence of construct validity for eye-hand coordination skill on the LAP Mentor.
Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A
2014-01-01
In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative 'top-down' processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG.
Steuwe, Carolin; Daniels, Judith K.; Frewen, Paul A.; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A.
2014-01-01
In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative ‘top–down’ processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG. PMID:22977200
Retinal image quality and visual stimuli processing by simulation of partial eye cataract
NASA Astrophysics Data System (ADS)
Ozolinsh, Maris; Danilenko, Olga; Zavjalova, Varvara
2016-10-01
Visual stimuli were demonstrated on a 4.3'' mobile phone screen inside a "Virtual Reality" adapter that allowed separation of the left and right eye visual fields. Contrast of the retina image thus can be controlled by the image on the phone screen and parallel to that at appropriate geometry by the AC voltage applied to scattering PDLC cell inside the adapter. Such optical pathway separation allows to demonstrate to both eyes spatially variant images, that after visual binocular fusion acquire their characteristic indications. As visual stimuli we used grey and different color (two opponent components to vision - red-green in L*a*b* color space) spatially periodical stimuli for left and right eyes; and with spatial content that by addition or subtraction resulted as clockwise or counter clockwise slanted Gabor gratings. We performed computer modeling with numerical addition or subtraction of signals similar to processing in brain via stimuli input decomposition in luminance and color opponency components. It revealed the dependence of the perception psychophysical equilibrium point between clockwise or counter clockwise perception of summation on one eye image contrast and color saturation, and on the strength of the retinal aftereffects. Existence of a psychophysical equilibrium point in perception of summation is only in the presence of a prior adaptation to a slanted periodical grating and at the appropriate slant orientation of adaptation grating and/or at appropriate spatial grating pattern phase according to grating nods. Actual observer perception experiments when one eye images were deteriorated by simulated cataract approved the shift of mentioned psychophysical equilibrium point on the degree of artificial cataract. We analyzed also the mobile devices stimuli emission spectra paying attention to areas sensitive to macula pigments absorption spectral maxima and blue areas where the intense irradiation can cause in abnormalities in periodic melatonin regeneration and deviations in regular circadian rhythms. Therefore participants in vision studies using "Virtual Reality" appliances with fixed vision fields and emitting a spike liked spectral bands (on basis of OLED and AMOLED diodes) different from spectra of ambient illuminators should be accordingly warned about potential health risks.
Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes
Boulos, Maged N Kamel; Robinson, Larry R
2009-01-01
Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system. PMID:19849837
Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes.
Boulos, Maged N Kamel; Robinson, Larry R
2009-10-22
Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system.
Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes
Boulos, Maged N.K.; Robinson, Larry R.
2009-01-01
Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system.
Looking at a predator with the left or right eye: asymmetry of response in lizards.
Bonati, Beatrice; Csermely, Davide; Sovrano, Valeria Anna
2013-01-01
Studies carried out with the common wall lizard (Podarcis muralis) revealed preferential use of the left eye during responses to predatory threat in laboratory settings and in the wild. Here we tested lizards under monocular conditions of vision, using temporary eye-patching. Lizards were facing a (simulated) predatory threat laterally, from the side of the non-patched eye. Results showed that lizards with the left eye uncovered during predatory threat used the left eye to monitor the predator, whereas lizards with the right eye uncovered nonetheless tried to use the covered left eye. Moreover, lizards frequently tried to change the eye exposition, making a body C-bend behaviour. Right-eyed lizards showed more frequent and faster C-bending responses than left-eyed lizards, trying to monitor the predator with the left eye even though it was patched. Results fit with asymmetries in spontaneous eye use observed in laboratory conditions and in the wild in this species, confirming that structures located on the right side of the brain (mainly served by the left eye) predominantly attend to predatory threat.
Statistical virtual eye model based on wavefront aberration
Wang, Jie-Mei; Liu, Chun-Ling; Luo, Yi-Ning; Liu, Yi-Guang; Hu, Bing-Jie
2012-01-01
Wavefront aberration affects the quality of retinal image directly. This paper reviews the representation and reconstruction of wavefront aberration, as well as the construction of virtual eye model based on Zernike polynomial coefficients. In addition, the promising prospect of virtual eye model is emphasized. PMID:23173112
The Importance of Postural Cues for Determining Eye Height in Immersive Virtual Reality
Leyrer, Markus; Linkenauger, Sally A.; Bülthoff, Heinrich H.; Mohler, Betty J.
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height. PMID:25993274
The importance of postural cues for determining eye height in immersive virtual reality.
Leyrer, Markus; Linkenauger, Sally A; Bülthoff, Heinrich H; Mohler, Betty J
2015-01-01
In human perception, the ability to determine eye height is essential, because eye height is used to scale heights of objects, velocities, affordances and distances, all of which allow for successful environmental interaction. It is well understood that eye height is fundamental to determine many of these percepts. Yet, how eye height itself is provided is still largely unknown. While the information potentially specifying eye height in the real world is naturally coincident in an environment with a regular ground surface, these sources of information can be easily divergent in similar and common virtual reality scenarios. Thus, we conducted virtual reality experiments where we manipulated the virtual eye height in a distance perception task to investigate how eye height might be determined in such a scenario. We found that humans rely more on their postural cues for determining their eye height if there is a conflict between visual and postural information and little opportunity for perceptual-motor calibration is provided. This is demonstrated by the predictable variations in their distance estimates. Our results suggest that the eye height in such circumstances is informed by postural cues when estimating egocentric distances in virtual reality and consequently, does not depend on an internalized value for eye height.
Advantages in exploring a new environment with the left eye in lizards.
Bonati, Beatrice; Csermely, Davide; Sovrano, Valeria Anna
2013-07-01
Lizards (Podarcis muralis) preferentially use the left eye during spatial exploration in a binocular condition. Here we allowed 44 adult wild lizards to explore an unknown maze for 20 min under a temporary monocular condition whilst recording their movements, particularly the direction of turns made whilst walking within the maze. Lizards with a patch on their right eye, i.e. using their left eye to monitor the environment, moved faster than lizards with a patch on their left eye when turning both leftward and rightward in a T-cross. Hence, right eye-patched lizards were faster than left eye-patched lizards also in turning right, although their right eye was covered. Thus, lizards that could use the left eye/right hemisphere to attend spatial cues appeared to have more control and to be more prompt in exploring the maze. In addition, female lizards with their left eye covered stopped very frequently when they reached crosses, showing a high level of indecision. Results confirm that P. muralis lizards using their left eye only in exploring a new environment react faster and more efficiently than those using the right eye only in exploration. Hence lateralisation of spatial stimuli mediated by the left eye/right hemisphere could provide an advantage to this species. Copyright © 2013 Elsevier B.V. All rights reserved.
A Case of Uveal Colobomas Showing Marked Left-Right Difference in Diabetic Retinopathy.
Moriya, Takeshi; Ochi, Ryosuke; Imagawa, Yukihiro; Sato, Bumpei; Morishita, Seita; Tonari, Masahiro; Fukumoto, Masanori; Suzuki, Hiroyuki; Kobayashi, Takatoshi; Kida, Teruyo; Ikeda, Tsunehiko
2016-01-01
Congenital uveal colobomas, including inferior iris and choroidal colobomas, are associated with microcornea and microphthalmia and often show left-right differences (laterality). The purpose of this study was to report a case of choroidal coloboma associated with left-right differences in diabetic retinopathy (DR). This study reports a 59-year-old male with bilateral iris and choroidal colobomas. The colobomatous area in the patient's right eye extended to the macula, and his right eye had been amblyopic since birth. The colobomatous area in his left eye was less extensive and did not involve the macula. Examination of the patient's left eye revealed multiple hemorrhages and hard exudates in the macula due to DR, but examination of his right eye showed almost no changes in DR, thus revealing a marked left-right difference. Optical coherence tomography showed more extensive retinal thinning in the patient's right eye than in his left eye. Fluorescein fundus angiography revealed a retinal nonperfusion area only in the left eye, and panretinal photocoagulation was subsequently performed. Our findings show that the reason for the left-right difference in DR was attributed to the more severe choroidal coloboma and retinal thinning in the patient's right eye compared to his left eye, thus reducing oxygen demand, as is also seen in eyes with severe myopia.
Gorynia, Inge; Schwaiger, Markus; Heinz, Andreas
2014-12-01
Based on the previous findings, it has been assumed that in schizophrenia patients, eye dominance and cannabis use will affect negative symptoms and intermanual coordination (IMC), an index of interhemispheric communication. But eye dominance, specifically the clinical findings for it, has been neglected in schizophrenia research. We therefore investigated its effects in 52 right-handed (36 right-eyed and 16 left-eyed) and 51 left-handed (35 left-eyed and 16 right-eyed) schizophrenia in-patients without and with drug use. Eye dominance affected IMC in all schizophrenia patients. When comparing right- and left-handers, we found that this result was only significant in the right-handed patients and in the smaller subgroup without drug use. In the right-handers, left eye dominance-like left-handedness-was associated with higher values in IMC and less pronounced manifestation of negative symptoms, right eye dominance was not. Thus, left-eyed right-handers may be more closely related to left-handers than to right-handers. In accordance with the results from the literature, we suggest that these findings are due to better interhemispheric connections and less impairment of white matter structures, especially in right-hemispheric regions. Moreover, cannabis use was related to higher scores in IMC and less pronounced negative symptoms, but only in the right-eyed and not in the left-eyed right-handers or in the left-handers. Hence, differences in eye dominance and handedness may be partially responsible for different results in interhemispheric connections among cannabis users. In conclusion, both eye dominance and use of cannabis should be taken into account when assessing clinical symptoms in schizophrenia patients.
Astronaut Prepares for Mission With Virtual Reality Hardware
NASA Technical Reports Server (NTRS)
2001-01-01
Astronaut John M. Grunsfeld, STS-109 payload commander, uses virtual reality hardware at Johnson Space Center to rehearse some of his duties prior to the STS-109 mission. The most familiar form of virtual reality technology is some form of headpiece, which fits over your eyes and displays a three dimensional computerized image of another place. Turn your head left and right, and you see what would be to your sides; turn around, and you see what might be sneaking up on you. An important part of the technology is some type of data glove that you use to propel yourself through the virtual world. This technology allows NASA astronauts to practice International Space Station work missions in advance. Currently, the medical community is using the new technologies in four major ways: To see parts of the body more accurately, for study, to make better diagnosis of disease and to plan surgery in more detail; to obtain a more accurate picture of a procedure during surgery; to perform more types of surgery with the most noninvasive, accurate methods possible; and to model interactions among molecules at a molecular level.
Wilson, Mark; McGrath, John; Vine, Samuel; Brewer, James; Defriend, David; Masters, Richard
2010-10-01
Surgical simulation is increasingly used to facilitate the adoption of technical skills during surgical training. This study sought to determine if gaze control parameters could differentiate between the visual control of experienced and novice operators performing an eye-hand coordination task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Typically adopted hand movement metrics reflect only one half of the eye-hand coordination relationship; therefore, little is known about how hand movements are guided and controlled by vision. A total of 14 right-handed surgeons were categorised as being either experienced (having led more than 70 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The eight experienced and six novice surgeons completed the eye-hand coordination task from the LAP Mentor basic skills package while wearing a gaze registration system. A variety of performance, movement, and gaze parameters were recorded and compared between groups. The experienced surgeons completed the task significantly more quickly than the novices, but only the economy of movement of the left tool differentiated skill level from the LAP Mentor parameters. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. The findings of the study provide support for the utility of assessing strategic gaze behaviour to better understand the way in which surgeons utilise visual information to plan and control tool movements in a virtual reality laparoscopic environment. It is hoped that by better understanding the limitations of the psychomotor system, effective gaze training programs may be developed.
McGrath, John; Vine, Samuel; Brewer, James; Defriend, David; Masters, Richard
2010-01-01
Background Surgical simulation is increasingly used to facilitate the adoption of technical skills during surgical training. This study sought to determine if gaze control parameters could differentiate between the visual control of experienced and novice operators performing an eye-hand coordination task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Typically adopted hand movement metrics reflect only one half of the eye-hand coordination relationship; therefore, little is known about how hand movements are guided and controlled by vision. Methods A total of 14 right-handed surgeons were categorised as being either experienced (having led more than 70 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The eight experienced and six novice surgeons completed the eye-hand coordination task from the LAP Mentor basic skills package while wearing a gaze registration system. A variety of performance, movement, and gaze parameters were recorded and compared between groups. Results The experienced surgeons completed the task significantly more quickly than the novices, but only the economy of movement of the left tool differentiated skill level from the LAP Mentor parameters. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. Conclusion The findings of the study provide support for the utility of assessing strategic gaze behaviour to better understand the way in which surgeons utilise visual information to plan and control tool movements in a virtual reality laparoscopic environment. It is hoped that by better understanding the limitations of the psychomotor system, effective gaze training programs may be developed. PMID:20333405
Effects of monocular viewing and eye dominance on spatial attention.
Roth, Heidi L; Lora, Andrea N; Heilman, Kenneth M
2002-09-01
Observations in primates and patients with unilateral spatial neglect have suggested that patching of the eye ipsilateral to the injury and contralateral to the neglected space can sometimes improve attention to the neglected space. Investigators have generally attributed the effects of monocular eye patching to activation of subcortical centers that interact with cortical attentional systems. Eye patching is thought to produce preferential activation of attentional systems contralateral to the viewing eye. In this study we examined the effect of monocular eye patching on attentional biases in normal subjects. When normal subjects bisect vertical (radial) lines using both eyes, they demonstrate a far attentional bias, misbisecting lines away from their body. In a monocular viewing experiment, we found that the majority of subjects, who were right eye dominant, had relatively nearer bisections and a diminished far bias when they used their right eye (left eye covered) compared with when they used their left eye (right eye covered). The smaller group of subjects who were left eye dominant had relatively nearer bisections and a diminished far bias when they used their left eye compared with when they used their right eye. In the hemispatial placement experiment, we directly manipulated hemispheric engagement by having subjects perform the same task in right and left hemispace. We found that right eye dominant subjects had a diminished far bias in right hemispace relative to left hemispace. Left eye dominant subjects showed the opposite pattern and had a diminished far bias in left hemispace. For both groups, spatial presentation affected performance more for the non-dominant eye. The results suggest that monocular viewing is associated with preferential activation of attentional systems in the contralateral hemisphere, and that the right hemisphere (at least in right eye dominant subjects) is biased towards far space. Finally, the results suggest that the poorly understood phenomenon of eye dominance may be related to hemispheric specialization for visual attention.
Virtual view image synthesis for eye-contact in TV conversation system
NASA Astrophysics Data System (ADS)
Murayama, Daisuke; Kimura, Keiichi; Hosaka, Tadaaki; Hamamoto, Takayuki; Shibuhisa, Nao; Tanaka, Seiichi; Sato, Shunichi; Saito, Sakae
2010-02-01
Eye-contact plays an important role for human communications in the sense that it can convey unspoken information. However, it is highly difficult to realize eye-contact in teleconferencing systems because of camera configurations. Conventional methods to overcome this difficulty mainly resorted to space-consuming optical devices such as half mirrors. In this paper, we propose an alternative approach to achieve eye-contact by techniques of arbitrary view image synthesis. In our method, multiple images captured by real cameras are converted to the virtual viewpoint (the center of the display) by homography, and evaluation of matching errors among these projected images provides the depth map and the virtual image. Furthermore, we also propose a simpler version of this method by using a single camera to save the computational costs, in which the only one real image is transformed to the virtual viewpoint based on the hypothesis that the subject is located at a predetermined distance. In this simple implementation, eye regions are separately generated by comparison with pre-captured frontal face images. Experimental results of both the methods show that the synthesized virtual images enable the eye-contact favorably.
1989-08-01
paths for integration with the off-aperture and dual-mirror VPD designs. PREFACE The goal of this work was to explore integration of an eye line-of- gaze ...Relationship in one plane between point-of- gaze on a flat scene and relative eye, detector, and scene positions...and eye line-of- gaze measurement. As a first step towards the design of an appropriate eye trac.<ing system for interface with the virtual cockpit
Middleton, Kellie K; Hamilton, Travis; Tsai, Pei-Chien; Middleton, Dana B; Falcone, John L; Hamad, Giselle
2013-11-01
Video games have been shown to improve eye-hand coordination, spatial visualization, manual dexterity, and rapid mental processing, which are important in the acquisition of laparoscopic skills. This study investigated the relationship between playing Nintendo(®) Wii™ and virtual reality (VR) laparoscopic surgery simulator performance. We hypothesized that playing the Wii would improve surgical skills performance on a VR laparoscopic simulator and hoped to elucidate which tasks, in particular, would be most beneficial for nondominant hand training. This was a single-blinded, randomized, prospective study conducted with 23 student volunteers. VR laparoscopic skills were assessed at baseline on a Simbionix LapMentor™ Surgical Simulator (Simbionix Ltd., Israel) and after the gaming period of 2 weeks. Simulator performance metrics were compared between groups using nonparametric statistics and an alpha of 0.05. Compared with the control group, the Wii-playing group demonstrated greater improvement of six measures, including accuracy on the eye-hand coordination task (p = 0.04), faster completion time (p = 0.04), decreased number of left-handed movements (p = 0.03), decreased left handed total path length (p = 0.03), decreased total number of grasping attempts (p = 0.04), and improved left-handed economy of movement (p = 0.05) for the bimanual clipping and grasping task. When comparing the number of measures improved upon by the Wii-playing group and the control group for all three tasks, the Wii-playing group consistently outperformed the control group in 18 measures compared with the control group's improvement in 6. This study further characterizes the association between video game playing and surgical performance. Improvements following the intervention were made in the most basic of surgical skills, most notably with the nondominant hand, suggesting that short-term playing of the Wii could improve bimanual dexterity and expedite the acquisition of basic surgical skills.
Real-time recording and classification of eye movements in an immersive virtual environment.
Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary
2013-10-10
Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements.
Real-time recording and classification of eye movements in an immersive virtual environment
Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary
2013-01-01
Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements. PMID:24113087
The effects of left and right monocular viewing on hemispheric activation.
Wang, Chao; Burtis, D Brandon; Ding, Mingzhou; Mo, Jue; Williamson, John B; Heilman, Kenneth M
2018-03-01
Prior research has revealed that whereas activation of the left hemisphere primarily increases the activity of the parasympathetic division of the autonomic nervous system, right-hemisphere activation increases the activity of the sympathetic division. In addition, each hemisphere primarily receives retinocollicular projections from the contralateral eye. A prior study reported that pupillary dilation was greater with left- than with right-eye monocular viewing. The goal of this study was to test the alternative hypotheses that this asymmetric pupil dilation with left-eye viewing was induced by activation of the right-hemispheric-mediated sympathetic activity, versus a reduction of left-hemisphere-mediated parasympathetic activity. Thus, this study was designed to learn whether there are changes in hemispheric activation, as measured by alteration of spontaneous alpha activity, during right versus left monocular viewing. High-density electroencephalography (EEG) was recorded from healthy participants viewing a crosshair with their right, left, or both eyes. There was a significantly less alpha power over the right hemisphere's parietal-occipital area with left and binocular viewing than with right-eye monocular viewing. The greater relative reduction of right-hemisphere alpha activity during left than during right monocular viewing provides further evidence that left-eye viewing induces greater increase in right-hemisphere activation than does right-eye viewing.
Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel-Robert; Amedi, Amir
2013-01-01
Virtual worlds and environments are becoming an increasingly central part of our lives, yet they are still far from accessible to the blind. This is especially unfortunate as such environments hold great potential for them for uses such as social interaction, online education and especially for use with familiarizing the visually impaired user with a real environment virtually from the comfort and safety of his own home before visiting it in the real world. We have implemented a simple algorithm to improve this situation using single-point depth information, enabling the blind to use a virtual cane, modeled on the “EyeCane” electronic travel aid, within any virtual environment with minimal pre-processing. Use of the Virtual-EyeCane, enables this experience to potentially be later used in real world environments with identical stimuli to those from the virtual environment. We show the fast-learned practical use of this algorithm for navigation in simple environments. PMID:23977316
Kim, Ho Soong; Park, Ki Ho; Jeoung, Jin Wook
2013-11-01
To evaluate the amount of intraocular pressure (IOP) change in the eye against the pillow in the lateral decubitus position (LDP). Thirty eyes from 15 healthy volunteers (12 men and three women) aged 29 ± 3 (range 25-37) years participated in this study. Using the rebound tonometer (Icare PRO, Icare Finland Oy, Helsinki, Finland), the IOP of both eyes was checked in sitting, supine, right and left LDPs. In the LDP, the additional IOP measurements were taken with the lower eyeball against the latex pillow. Baseline IOP in the sitting position was 12.7 ± 1.9 mmHg in the right eye and 12.8 ± 2.2 mmHg in the left eye. Ten minutes after shifting from the sitting to the supine position, IOP increased significantly (right eye: +1.4 ± 1.4 mmHg, p = 0.006; left eye: +1.8 ± 1.5 mmHg, p = 0.001). Changing from the supine to the right and left LDP increased significantly the IOP of dependent eye (right eye: +2.3 ± 1.8 mmHg, p = 0.001; left eye: +1.5 ± 1.8 mmHg, p = 0.011). When the dependent eye was compressed against the pillow in the LDP, the IOP of the dependent eyes increased significantly after 10 min (right eye in the right LDP: +4.1 ± 4.9 mmHg, p = 0.011; left eye in the left LDP: +3.4 ± 3.7 mmHg, p = 0.006). The IOP was significantly elevated when the eyeball was against the pillow in the LDP. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.
Shin, Ji-Won; Song, Gui-Bin; Hwangbo, Gak
2015-07-01
[Purpose] The purpose of the study was to evaluate the effects of conventional neurological treatment and a virtual reality training program on eye-hand coordination in children with cerebral palsy. [Subjects] Sixteen children (9 males, 7 females) with spastic diplegic cerebral palsy were recruited and randomly assigned to the conventional neurological physical therapy group (CG) and virtual reality training group (VRG). [Methods] Eight children in the control group performed 45 minutes of therapeutic exercise twice a week for eight weeks. In the experimental group, the other eight children performed 30 minutes of therapeutic exercise and 15 minutes of a training program using virtual reality twice a week during the experimental period. [Results] After eight weeks of the training program, there were significant differences in eye-hand coordination and visual motor speed in the comparison of the virtual reality training group with the conventional neurological physical therapy group. [Conclusion] We conclude that a well-designed training program using virtual reality can improve eye-hand coordination in children with cerebral palsy.
Testing of visual field with virtual reality goggles in manual and visual grasp modes.
Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.
Beam steering for virtual/augmented reality displays with a cycloidal diffractive waveplate.
Chen, Haiwei; Weng, Yishi; Xu, Daming; Tabiryan, Nelson V; Wu, Shin-Tson
2016-04-04
We proposed a switchable beam steering device with cycloidal diffractive waveplate (CDW) for eye tracking in a virtual reality (VR) or augmented reality (AR) display system. Such a CDW diffracts the incident circularly polarized light to the first order with over 95% efficiency. To convert the input linearly polarized light to right-handed or left-handed circular polarization, we developed a broadband polarization switch consisting of a twisted nematic liquid crystal cell and an achromatic quarter-wave retardation film. By cascading 2-3 CDWs together, multiple diffraction angles can be achieved. To suppress the color dispersion, we proposed two approaches to obtain the same diffraction angle for red, green, and blue LEDs-based full color displays. Our device exhibits several advantages, such as high diffraction efficiency, fast response time, low power consumption, and low cost. It holds promise for the emerging VR/AR displays.
Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes
Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326
Uveitic crystalline maculopathy.
Or, Chris; Kirker, Andrew W; Forooghian, Farzin
2015-01-01
The purpose of this case report is to present a novel cause of crystalline maculopathy. A 52-year-old Japanese female presented with a 4-month history of decreased vision in the left eye. Best corrected visual acuity in the left eye was 20/40. Dilated fundus examination of the right eye was unremarkable, but that of the left eye demonstrated foveal yellow-green intraretinal crystals and mild vitritis. Optical coherence tomography of the left eye revealed small intraretinal fluid cysts and intraretinal crystals. Ultra-widefield fluorescein angiography was normal in the right eye, but that of the left eye demonstrated features of intermediate uveitis. There was no history or findings to suggest any cause for the crystals other than the uveitis. We propose that this may represent a novel category of crystalline retinopathy, termed uveitic crystalline maculopathy. We hypothesize that breakdown of the blood-retinal barrier as seen in uveitis may contribute to the deposition of crystals in the macula, although the precise composition of the crystals is unknown.
Liu, Dan; Hu, Kai; Nordbeck, Peter; Ertl, Georg; Störk, Stefan; Weidemann, Frank
2016-05-10
Despite substantial advances in the imaging techniques and pathophysiological understanding over the last decades, identification of the underlying causes of left ventricular hypertrophy by means of echocardiographic examination remains a challenge in current clinical practice. The longitudinal strain bull's eye plot derived from 2D speckle tracking imaging offers an intuitive visual overview of the global and regional left ventricular myocardial function in a single diagram. The bull's eye mapping is clinically feasible and the plot patterns could provide clues to the etiology of cardiomyopathies. The present review summarizes the longitudinal strain, bull's eye plot features in patients with various cardiomyopathies and concentric left ventricular hypertrophy and the bull's eye plot features might serve as one of the cardiac workup steps on evaluating patients with left ventricular hypertrophy.
Miller, Haylie L.; Bugnariu, Nicoleta; Patterson, Rita M.; Wijayasinghe, Indika; Popa, Dan O.
2018-01-01
Visuomotor integration (VMI), the use of visual information to guide motor planning, execution, and modification, is necessary for a wide range of functional tasks. To comprehensively, quantitatively assess VMI, we developed a paradigm integrating virtual environments, motion-capture, and mobile eye-tracking. Virtual environments enable tasks to be repeatable, naturalistic, and varied in complexity. Mobile eye-tracking and minimally-restricted movement enable observation of natural strategies for interacting with the environment. This paradigm yields a rich dataset that may inform our understanding of VMI in typical and atypical development. PMID:29876370
ERIC Educational Resources Information Center
Orman, Evelyn K.
2016-01-01
This study examined the effects of virtual reality immersion with audio on eye contact, directional focus and focus of attention for novice wind band conductors. Participants (N = 34) included a control group (n = 12) and two virtual reality groups with (n = 10) and without (n = 12) head tracking. Participants completed conducting/score study…
Integrated Eye Tracking and Neural Monitoring for Enhanced Assessment of Mild TBI
2015-04-01
virtual reality driving simulator data acquisition. Data collection for the pilot study is nearly complete and data analyses are currently under way...Training for primary study procedures including neuropsychological testing, eye- tracking, virtual reality driving simulator, and EEG data acquisition is...the virtual reality driving simulator. Participants are instructed to drive along a coastal highway while performing the target detection task
Cytomegalovirus retinitis and HIV: Case reviews from KwaZulu-Natal Province, South Africa.
Hassan-Moosa, R; Chinappa, T; Jeena, L; Visser, L; Naidoo, K
2017-09-22
Retinal cytomegalovirus (CMV) infection is a common opportunistic infection and remains a significant contributor to visual loss in patients with AIDS. We highlight the poor outcomes of CMV retinitis in three HIV-infected patients who were initiated on antiretroviral therapy (ART). We conducted a retrospective chart review of advanced stage HIV-infected patients with known CMV retinitis.Case 1. A 37-year-old man, with a CD4+ cell count of 35 cells/µL, presented for ART initiation with a 5-month history of visual loss in his left eye. Fundoscopy showed left eye CMV retinitis and right eye HIV retinopathy. ART and 5 months of weekly intravitreal ganciclovir injections (left eye) were commenced. Six-month outcomes included virological suppression, and visual acuity in the right eye of 6/6 and in the left eye of 3/60.Case 2. A 31-year-old woman, with a CD4+ cell count of 39 cells/µL and on tuberculosis therapy, presented for ART initiation. She presented with a 2-month history of decreased visual acuity. Fundoscopy showed bilateral CMV retinitis, which was more pronounced in the left eye. ART and 8 months of intravitreal ganciclovir injections were commenced. Six-month outcomes included virological suppression and visual acuity in the right eye of 6/9, and in the left eye of 6/24.Case 3. A 29-year-old woman, with a CD4+ cell count of 24 cells/µL, who was on tuberculosis therapy and ART, complained of blurred vision at her 2-month ART follow-up visit. Fundoscopy showed bilateral retinal detachment secondary to CMV retinitis. While silicone oil tamponade and subsequent retinectomy successfully repaired the right eye, extensive damage rendered the left eye irreparable. Six-month outcomes included virological suppression, with 6/120 visual acuity in the right eye and complete blindness in the left eye. CMV retinitis causes debilitating, permanent sequelae, which is preventable by ART initiation at higher CD4+ cell counts. Despite achieving virological suppression, vision could not be completely restored in these patients, irrespective of the severity of CMV retinitis.
Chou, Chien-Chih; Chen, Hsin-Han; Tsai, Yi-Yu; Li, You-Ling; Lin, Hui-Ju
2015-03-08
We reported a case of sudden monocular vision loss after calcium hydroxyapatite (CaHA) injection into the nasal tip and dorsum with detailed retina images. A healthy, 35-year-old woman received CaHA filler injection for nose augmentation. Ten minutes after the procedure, she developed nausea, vomiting, headache, ptosis, and left periorbital pain. After 30 minutes, she complained of progressively blurring vision in the left eye. The best-corrected visual acuity (BCVA) in her left eye was 30 cm ahead of hand motion. Left exotropia was noted in primary gaze. Limitations in adduction, supraduction, and infraduction of the left eye were also observed. Slit lamp examination of the left eye revealed a pink conjunctiva, a clear cornea, a mild anterior chamber reaction, a sluggish papillary light reflex, and a semi-dilated pupil. A positive relative afferent pupillary defect was observed in the left eye. Fundus examination revealed optic disc edema and some linear whitish opacity over the superior and temporal sites in the left eye, suggesting multiple CaHA emboli in the choroid vessels. Although the majority of adverse reactions are mild and transient, surgeons should be alert about extremely rare serious adverse events such as visual loss.
Bornhoft, J M; Strabala, K W; Wortman, T D; Lehman, A C; Oleynikov, D; Farritor, S M
2011-01-01
The objective of this research is to study the effectiveness of using a stereoscopic visualization system for performing remote surgery. The use of stereoscopic vision has become common with the advent of the da Vinci® system (Intuitive, Sunnyvale CA). This system creates a virtual environment that consists of a 3-D display for visual feedback and haptic tactile feedback, together providing an intuitive environment for remote surgical applications. This study will use simple in vivo robotic surgical devices and compare the performance of surgeons using the stereoscopic interfacing system to the performance of surgeons using one dimensional monitors. The stereoscopic viewing system consists of two cameras, two monitors, and four mirrors. The cameras are mounted to a multi-functional miniature in vivo robot; and mimic the depth perception of the actual human eyes. This is done by placing the cameras at a calculated angle and distance apart. Live video streams from the left and right cameras are displayed on the left and right monitors, respectively. A system of angled mirrors allows the left and right eyes to see the video stream from the left and right monitor, respectively, creating the illusion of depth. The haptic interface consists of two PHANTOM Omni® (SensAble, Woburn Ma) controllers. These controllers measure the position and orientation of a pen-like end effector with three degrees of freedom. As the surgeon uses this interface, they see a 3-D image and feel force feedback for collision and workspace limits. The stereoscopic viewing system has been used in several surgical training tests and shows a potential improvement in depth perception and 3-D vision. The haptic system accurately gives force feedback that aids in surgery. Both have been used in non-survival animal surgeries, and have successfully been used in suturing and gallbladder removal. Bench top experiments using the interfacing system have also been conducted. A group of participants completed two different surgical training tasks using both a two dimensional visual system and the stereoscopic visual system. Results suggest that the stereoscopic visual system decreased the amount of time taken to complete the tasks. All participants also reported that the stereoscopic system was easier to utilize than the two dimensional system. Haptic controllers combined with stereoscopic vision provides for a more intuitive virtual environment. This system provides the surgeon with 3-D vision, depth perception, and the ability to receive feedback through forces applied in the haptic controller while performing surgery. These capabilities potentially enable the performance of more complex surgeries with a higher level of precision.
75 FR 1835 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-13
.... John E. Cain Mr. Cain, 59, has a retinal detachment in his left eye due to a traumatic injury sustained... CMV. Curtis J. Crowston Mr. Crowston, 44, has a prosthetic left eye due to a traumatic injury... to a traumatic injury sustained during childhood. The best corrected visual acuity in his left eye is...
Bilateral anterior segment dysgenesis with the presumed Peters' anomaly in a cat.
Park, Sangwan; Kim, Kiwoong; Kim, Youngbeum; Seo, Kangmoon
2018-02-20
A seven-month-old female domestic shorthaired cat was presented for buphthalmos in the right eye and corneal cloudiness in the left eye. Full ophthalmic examinations were performed for both eyes and enucleation was done for the right nonvisual eye. Congenital glaucoma caused by anterior segment dysgenesis was confirmed for the right eye. In the left eye, slit-lamp examination revealed focal corneal edema with several iris strands from iris collarette to the affected posterior corneal surfaces. Circular posterior corneal defect was suggested to be the cause of edema. Goniodysgenesis, additionally, was identified. Taken together, the diagnosis of Peters' anomaly which is a subtype of anterior segment dysgenesis was suggested in the left eye.
77 FR 46793 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-06
..., had an enucleation of his left eye due to a traumatic injury sustained as a child. The visual acuity.... Johnsonbaugh, 42, has a prosthetic left eye due to a traumatic injury sustained in 1992. The visual acuity in... had retinal scarring in his left eye due to a traumatic injury sustained as a child. The best...
77 FR 17109 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... W. Doran, Jr. Mr. Doran, 51, has had a macular scar in his left eye due to a traumatic injury... prosthetic left eye due to a traumatic injury sustained 20 years ago. The best corrected visual acuity in... traumatic injury sustained at age 23. The best corrected visual acuity in left eye is 20/20. Following an...
Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: A rarely reported association
Mitra, Arijit; Ramakrishnan, R.; Kader, Mohideen Abdul
2014-01-01
A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature. PMID:25230966
Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: a rarely reported association.
Mitra, Arijit; Ramakrishnan, R; Kader, Mohideen Abdul
2014-08-01
A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature.
Human agency beliefs influence behaviour during virtual social interactions.
Caruana, Nathan; Spirou, Dean; Brock, Jon
2017-01-01
In recent years, with the emergence of relatively inexpensive and accessible virtual reality technologies, it is now possible to deliver compelling and realistic simulations of human-to-human interaction. Neuroimaging studies have shown that, when participants believe they are interacting via a virtual interface with another human agent, they show different patterns of brain activity compared to when they know that their virtual partner is computer-controlled. The suggestion is that users adopt an "intentional stance" by attributing mental states to their virtual partner. However, it remains unclear how beliefs in the agency of a virtual partner influence participants' behaviour and subjective experience of the interaction. We investigated this issue in the context of a cooperative "joint attention" game in which participants interacted via an eye tracker with a virtual onscreen partner, directing each other's eye gaze to different screen locations. Half of the participants were correctly informed that their partner was controlled by a computer algorithm ("Computer" condition). The other half were misled into believing that the virtual character was controlled by a second participant in another room ("Human" condition). Those in the "Human" condition were slower to make eye contact with their partner and more likely to try and guide their partner before they had established mutual eye contact than participants in the "Computer" condition. They also responded more rapidly when their partner was guiding them, although the same effect was also found for a control condition in which they responded to an arrow cue. Results confirm the influence of human agency beliefs on behaviour in this virtual social interaction context. They further suggest that researchers and developers attempting to simulate social interactions should consider the impact of agency beliefs on user experience in other social contexts, and their effect on the achievement of the application's goals.
Generating and Describing Affective Eye Behaviors
NASA Astrophysics Data System (ADS)
Mao, Xia; Li, Zheng
The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.
Pai, Vaibhav P.; Vandenberg, Laura N.; Blackiston, Douglas; Levin, Michael
2012-01-01
Consistent left-right asymmetry in organ morphogenesis is a fascinating aspect of bilaterian development. Although embryonic patterning of asymmetric viscera, heart, and brain is beginning to be understood, less is known about possible subtle asymmetries present in anatomically identical paired structures. We investigated two important developmental events: physiological controls of eye development and specification of neural crest derivatives, in Xenopus laevis embryos. We found that the striking hyperpolarization of transmembrane potential (V mem) demarcating eye induction usually occurs in the right eye field first. This asymmetry is randomized by perturbing visceral left-right patterning, suggesting that eye asymmetry is linked to mechanisms establishing primary laterality. Bilateral misexpression of a depolarizing channel mRNA affects primarily the right eye, revealing an additional functional asymmetry in the control of eye patterning by V mem. The ATP-sensitive K+ channel subunit transcript, SUR1, is asymmetrically expressed in the eye primordia, thus being a good candidate for the observed physiological asymmetries. Such subtle asymmetries are not only seen in the eye: consistent asymmetry was also observed in the migration of differentiated melanocytes on the left and right sides. These data suggest that even anatomically symmetrical structures may possess subtle but consistent laterality and interact with other developmental left-right patterning pathways. PMID:23346115
Pai, Vaibhav P; Vandenberg, Laura N; Blackiston, Douglas; Levin, Michael
2012-01-01
Consistent left-right asymmetry in organ morphogenesis is a fascinating aspect of bilaterian development. Although embryonic patterning of asymmetric viscera, heart, and brain is beginning to be understood, less is known about possible subtle asymmetries present in anatomically identical paired structures. We investigated two important developmental events: physiological controls of eye development and specification of neural crest derivatives, in Xenopus laevis embryos. We found that the striking hyperpolarization of transmembrane potential (V(mem)) demarcating eye induction usually occurs in the right eye field first. This asymmetry is randomized by perturbing visceral left-right patterning, suggesting that eye asymmetry is linked to mechanisms establishing primary laterality. Bilateral misexpression of a depolarizing channel mRNA affects primarily the right eye, revealing an additional functional asymmetry in the control of eye patterning by V(mem). The ATP-sensitive K(+) channel subunit transcript, SUR1, is asymmetrically expressed in the eye primordia, thus being a good candidate for the observed physiological asymmetries. Such subtle asymmetries are not only seen in the eye: consistent asymmetry was also observed in the migration of differentiated melanocytes on the left and right sides. These data suggest that even anatomically symmetrical structures may possess subtle but consistent laterality and interact with other developmental left-right patterning pathways.
Aversive eye gaze during a speech in virtual environment in patients with social anxiety disorder.
Kim, Haena; Shin, Jung Eun; Hong, Yeon-Ju; Shin, Yu-Bin; Shin, Young Seok; Han, Kiwan; Kim, Jae-Jin; Choi, Soo-Hee
2018-03-01
One of the main characteristics of social anxiety disorder is excessive fear of social evaluation. In such situations, anxiety can influence gaze behaviour. Thus, the current study adopted virtual reality to examine eye gaze pattern of social anxiety disorder patients while presenting different types of speeches. A total of 79 social anxiety disorder patients and 51 healthy controls presented prepared speeches on general topics and impromptu speeches on self-related topics to a virtual audience while their eye gaze was recorded. Their presentation performance was also evaluated. Overall, social anxiety disorder patients showed less eye gaze towards the audience than healthy controls. Types of speech did not influence social anxiety disorder patients' gaze allocation towards the audience. However, patients with social anxiety disorder showed significant correlations between the amount of eye gaze towards the audience while presenting self-related speeches and social anxiety cognitions. The current study confirms that eye gaze behaviour of social anxiety disorder patients is aversive and that their anxiety symptoms are more dependent on the nature of topic.
78 FR 10251 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-13
..., please include a self-addressed, stamped envelope or postcard or print the acknowledgement page that... since 2003. The visual acuity in his right eye is no light perception, and in his left eye, 20/20... right eye is light perception, and in his left eye, 20/20. Following an examination in 2012, his...
Petit, Laurent; Zago, Laure; Mellet, Emmanuel; Jobard, Gaël; Crivello, Fabrice; Joliot, Marc; Mazoyer, Bernard; Tzourio-Mazoyer, Nathalie
2015-03-01
Hemispheric lateralization for spatial attention and its relationships with manual preference strength and eye preference were studied in a sample of 293 healthy individuals balanced for manual preference. Functional magnetic resonance imaging was used to map this large sample while performing visually guided saccadic eye movements. This activated a bilateral distributed cortico-subcortical network in which dorsal and ventral attentional/saccadic pathways elicited rightward asymmetrical activation depending on manual preference strength and sighting eye. While the ventral pathway showed a strong rightward asymmetry irrespective of both manual preference strength and eye preference, the dorsal frontoparietal network showed a robust rightward asymmetry in strongly left-handers, even more pronounced in left-handed subjects with a right sighting-eye. Our findings brings support to the hypothesis that the origin of the rightward hemispheric dominance for spatial attention may have a manipulo-spatial origin neither perceptual nor motor per se but rather reflecting a mechanism by which a spatial context is mapped onto the perceptual and motor activities, including the exploration of the spatial environment with eyes and hands. Within this context, strongly left-handers with a right sighting-eye may benefit from the advantage of having the same right hemispheric control of their dominant hand and visuospatial attention processing. We suggest that this phenomenon explains why left-handed right sighting-eye athletes can outperform their competitors in sporting duels and that the prehistoric and historical constancy of the left-handers ratio over the general population may relate in part on the hemispheric specialization of spatial attention. © 2014 Wiley Periodicals, Inc.
Classical pathology of sympathetic ophthalmia presented in a unique case.
Chen, Shida; Aronow, Mary E; Wang, Charles; Shen, Defen; Chan, Chi-Chao
2014-01-01
The ocular pathology of sympathetic ophthalmia is demonstrated in a 10 year-old boy who sustained a penetrating left globe injury and subsequently developed sympathetic ophthalmia in the right eye two months later. Two and a half weeks following extensive surgical repair of the left ruptured globe, he developed endophthalmitis and was treated with oral and topical fortified antibiotics. One month after the initial injury, a progressive corneal ulcer of the left eye led to perforation and the need for emergent corneal transplantation. The surgical specimen revealed fungus, Scedosporium dehoogii. The boy received systemic and topical anti-fungal therapy. Two months following the penetrating globe injury of the left eye, a granulomatous uveitis developed in the right eye. Sympathetic ophthalmia was suspected and the patient began treatment with topical and oral corticosteroids. Given the concern of vision loss secondary to sympathetic ophthalmia in the right eye, as well as poor vision and hypotony in the injured eye, the left eye was enucleated. Microscopically, granulomatous inflammation with giant cells was noted within a cyclitic membrane which filled the anterior and posterior chamber of the left globe. Other classic features including Dalen-Fuchs nodules were identified. Small, choroidal, ill-defined granulomas and relative sparing of the choriocapillaris were present. Molecular analysis did not identify evidence of remaining fungal infection. The pathology findings were consistent with previously described features of sympathetic ophthalmia. The present case is unique in that co-existing fungal infection may have potentiated the risk for developing sympathetic ophthalmia in the fellow eye.
NASA Astrophysics Data System (ADS)
Viale, Alberto; Villa, Dario
2011-03-01
Recently stereoscopy has increased a lot its popularity and various technologies are spreading in theaters and homes allowing observation of stereoscopic images and movies, becoming affordable even for home users. However there are some golden rules that users should follow to ensure a better enjoyment of stereoscopic images, first of all the viewing condition should not be too different from the ideal ones, which were assumed during the production process. To allow the user to perceive stereo depth instead of a flat image, two different views of the same scene are shown to the subject, one is seen just through his left eye and the other just through the right one; the vision process is making the work of merging the two images in a virtual three-dimensional scene, giving to the user the perception of depth. The two images presented to the user were created, either from image synthesis or from more traditional techniques, following the rules of perspective. These rules need some boundary conditions to be explicit, such as eye separation, field of view, parallax distance, viewer position and orientation. In this paper we are interested in studying how the variation of the viewer position and orientation from the ideal ones expressed as specified parameters in the image creation process, is affecting the correctness of the reconstruction of the three-dimensional virtual scene.
Exploring virtual worlds with head-mounted displays
NASA Astrophysics Data System (ADS)
Chung, James C.; Harris, Mark R.; Brooks, F. P.; Fuchs, Henry; Kelley, Michael T.
1989-02-01
Research has been conducted in the use of simple head mounted displays in real world applications. Such units provide the user with non-holographic true 3-D information, since the kinetic depth effect, stereoscopy, and other visual cues combine to immerse the user in a virtual world which behaves like the real world in some respects. UNC's head mounted display was built inexpensively from commercially available off-the-shelf components. Tracking of the user's head position and orientation is performed by a Polhemus Navigation Sciences' 3SPACE tracker. The host computer uses the tracking information to generate updated images corresponding to the user's new left eye and right eye views. The images are broadcast to two liquid crystal television screens (220x320 pixels) mounted on a horizontal shelf at the user's forehead. The user views these color screens through half-silvered mirrors, enabling the computer generated image to be superimposed upon the user's real physical environment. The head mounted display was incorporated into existing molecular and architectural applications being developed at UNC. In molecular structure studies, chemists are presented with a room sized molecule with which they can interact in a manner more intuitive than that provided by conventional 2-D displays and dial boxes. Walking around and through the large molecule may provide quicker understanding of its structure, and such problems as drug enzyme docking may be approached with greater insight.
Reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old.
Megbelayin, E; Ekpenyong, S M; Azunobi, J; Ejiro, G
2014-03-01
To report a reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old. Case report. Eye clinic of a University Teaching Hospital in a metropolitan city. an index patient. Occlusion therapy. Post occlusion visual acuity. Presenting unaided visual acuity of right eye: 6/6, left eye: 4/60. Refraction result was: right eye: -0.50DS (6/6), left eye: -3.50DS (6/18). Following day time occlusion therapy of at least 6 hours for about 4 weeks, subjective refraction was: right eye: -0.5DS (6/5), left eye: -3.50DS (6/6(+3)). The remarkable improvement in vision at age 25 years of a patient with myopic anisometropic amblyopia shows that occlusion therapy might still be useful long after amblyogenic period.
Peterka, Tom; Kooima, Robert L; Sandin, Daniel J; Johnson, Andrew; Leigh, Jason; DeFanti, Thomas A
2008-01-01
A solid-state dynamic parallax barrier autostereoscopic display mitigates some of the restrictions present in static barrier systems, such as fixed view-distance range, slow response to head movements, and fixed stereo operating mode. By dynamically varying barrier parameters in real time, viewers may move closer to the display and move faster laterally than with a static barrier system, and the display can switch between 3D and 2D modes by disabling the barrier on a per-pixel basis. Moreover, Dynallax can output four independent eye channels when two viewers are present, and both head-tracked viewers receive an independent pair of left-eye and right-eye perspective views based on their position in 3D space. The display device is constructed by using a dual-stacked LCD monitor where a dynamic barrier is rendered on the front display and a modulated virtual environment composed of two or four channels is rendered on the rear display. Dynallax was recently demonstrated in a small-scale head-tracked prototype system. This paper summarizes the concepts presented earlier, extends the discussion of various topics, and presents recent improvements to the system.
Golshani, Cyrus; Gal-Or, Orly; Giovinazzo, Vincent; Freund, K Bailey
2017-11-07
To report an unusual case of an elderly patient with transient outer retinal disruption resembling bilateral multiple evanescent white dot syndrome. Observational case report. Fundus photographs, fluorescein angiography, standard and ultra-widefield fundus autofluorescence, and cross-sectional and en face optical coherence tomography were used to characterize and describe the clinical findings. A 67-year-old woman presented with decreased vision and floaters in her left eye. Best-corrected visual acuity was 20/20-3 in the right eye and 20/80-2 in the left eye. Funduscopic examination showed small deep white dots and foveal granularity of the left eye corresponding to hyperautofluorescent spots on fundus autofluorescence and ellipsoid zone disruption on spectral domain optical coherence tomography. The asymptomatic right eye had evidence of subretinal deposits on spectral domain optical coherence tomography but was otherwise unremarkable. At 4-week follow-up, the patient noted resolution of her symptoms in the left eye but had developed floaters and blurry vision in her right eye. The left eye showed resolving white spots and ellipsoid zone disruption. However, the right eye had new evidence of white spots corresponding to hyperautofluorescent spots on fundus autofluorescence. Spectral domain optical coherence tomography demonstrated subretinal deposits overlying areas of ellipsoid zone disruption. At 8-week follow-up, the patient was asymptomatic in both eyes with best-corrected visual acuity of 20/20 in both eyes. The hyperautofluorescent spots on ultra-widefield fundus autofluorescence had faded with restoration of ellipsoid zone disruption in both eyes and disappearance of subretinal deposits. Our case demonstrates multimodal retinal imaging findings resembling multiple evanescent white dot syndrome in an elderly patient. The bilateral presentation, presence of subretinal deposits before symptom onset, and older age of the patient were atypical features for this entity.
77 FR 10610 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
... optic nerve in his right eye due to a traumatic injury sustained in 1995. The best corrected visual.... Clark Mr. Clark, 66, has a detached retina in his left eye due to a traumatic injury sustained in 1967... eye due to a traumatic injury sustained as a child. The best corrected visual acuity in his left eye...
76 FR 40443 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
... traumatic injury that occurred in 1994. The best corrected visual acuity in his right eye is hand motion... his left eye due to a traumatic injury sustained in 1982. The visual acuity in his right eye is 20/20.... Newman Mr. Newman, 50, has no light perception in his left eye due to a traumatic injury that occurred...
Lustig, Avichai; Ketter-Katz, Hadas; Katzir, Gadi
2013-11-01
Chameleons (Chamaeleonidae, reptilia), in common with most ectotherms, show full optic nerve decussation and sparse inter-hemispheric commissures. Chameleons are unique in their capacity for highly independent, large-amplitude eye movements. We address the question: Do common chameleons, Chamaeleo chameleon, during detour, show patterns of lateralization of motion and of eye use that differ from those shown by other ectotherms? To reach a target (prey) in passing an obstacle in a Y-maze, chameleons were required to make a left or a right detour. We analyzed the direction of detours and eye use and found that: (i) individuals differed in their preferred detour direction, (ii) eye use was lateralized at the group level, with significantly longer durations of viewing the target with the right eye, compared with the left eye, (iii) during left side, but not during right side, detours the durations of viewing the target with the right eye were significantly longer than the durations with the left eye. Thus, despite the uniqueness of chameleons' visual system, they display patterns of lateralization of motion and of eye use, typical of other ectotherms. These findings are discussed in relation to hemispheric functions. Copyright © 2013 Elsevier B.V. All rights reserved.
Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.
Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K
2010-02-01
Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.
Simulation of eye disease in virtual reality.
Jin, Bei; Ai, Zhuming; Rasmussen, Mary
2005-01-01
It is difficult to understand verbal descriptions of visual phenomenon if one has no such experience. Virtual Reality offers a unique opportunity to "experience" diminished vision and the problems it causes in daily life. We have developed an application to simulate age-related macular degeneration, glaucoma, protanopia, and diabetic retinopathy in a familiar setting. The application also includes the introduction of eye anatomy representing both normal and pathologic states. It is designed for patient education, health care practitioner training, and eye care specialist education.
78 FR 41975 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-12
... violations in a CMV. Westcott G. Clarke Mr. Clarke, 63, has had optic neuropathy in his left eye since 2003... optic neuropathy in his left eye since 2008. The visual acuity in his right eye is 20/25, and in his...
Syringomyelia presenting with unilateral optic neuropathy: a case report.
Ngoo, Qi Zhe; Tai, Evelyn Li Min; Wan Hitam, Wan Hazabbah
2017-01-01
In this case report, we present two cases of syringomyelia with optic neuropathy. In Case 1, a 36-year-old Malay lady presented to our clinic with acute onset of blurring of vision in her left eye that she experienced since past 1 month. She was diagnosed with syringomyelia 12 years ago and was on conservative management. Her visual acuity was 6/6 in the right eye and counting fingers at 1 m in the left. There was a positive relative afferent pupillary defect in her left eye. Optic nerve functions of her left eye were reduced. Visual field showed a left inferior field defect. Her extraocular muscle movements were full. Magnetic resonance imaging of the brain and spine showed syringomyelia at the level of C2-C6 and T2-T9. Both of her optic nerves were normal. Her condition improved with intravenous and oral corticosteroids. In Case 2, a 44-year-old Malay lady presented to our clinic with a progressive central scotoma in her right eye that she experienced since past 1 month. She had previous history of recurrent episodes of weakness in both of her lower limbs from past 8 months. Visual acuity in her right and left eye was 6/9 and 6/6, respectively. The relative afferent pupillary defect in her right eye was positive. Optic nerve functions of her right eye were affected. Visual field showed a central scotoma in her right eye. Her extraocular muscle movements were full. Fundoscopy of her right eye showed a pale optic disc. Her left eye fundus was normal. Magnetic resonance imaging of the brain and spine showed syringomyelia at T3-T6. Both of her optic nerves were normal. A diagnosis of syringomyelia with right optic atrophy was performed. Her condition improved with intravenous and oral corticosteroids. Optic neuropathy is a rare neuro-ophthalmic manifestation in patients with syringomyelia. Prompt diagnosis and timely management are essential to avoid a poor visual outcome. Intravenous corticosteroids are beneficial in the treatment of early optic neuropathy in syringomyelia.
Considerations on the mechanisms of alternating skew deviation in patients with cerebellar lesions.
Zee, D S
1996-01-01
Alternating skew deviation, in which the side of the higher eye changes depending upon whether gaze is directed to the left or the right, is a frequent sign in patients with posterior fossa lesions, including those restricted to the cerebellum. Here we propose a mechanism for alternating skews related to the otolith-ocular responses to fore and aft pitch of the head in lateral-eyed animals. In lateral-eyed animals the expected response to a static head pitch is cyclorotation of the eyes. But if the eyes are rotated horizontally in the orbit, away from the primary position, a compensatory skew deviation should also appear. The direction of the skew would depend upon whether the eyes were directed to the right (left eye forward, right eye backward) or to the left (left eye backward, right eye forward). In contrast, for frontal-eyed animals, skew deviations are counterproductive because they create diplopia and interfere with binocular vision. We attribute the emergence of skew deviations in frontal-eyed animals in pathological conditions to 1) an imbalance in otolithocular pathways and 2) a loss of the component of ocular motor innervation that normally corrects for the differences in pulling directions and strengths of the various ocular muscles as the eyes change position in the orbit. Such a compensatory mechanism is necessary to ensure optimal binocular visual function during and after head motion. This compensatory mechanism may depend upon the cerebellum.
Jiang, Zhen-ying; Qu, Xiao-mei; Li, Xiao-xin; Liu, Yu-ling; Shen, Nian-ci; Zhang, Lin; Ke, Bi-lian; Zhao, Pei-quan; Jiang, Jun; Yao, Ke; Zeng, Jin; Yang, Xiao; Chu, Ren-yuan
2010-12-01
To study the clinical efficacy and safety of the Esculin and Digitalis glycosides Eye Drops used in the patients of ametropic asthenopia. Multicenter clinical trial. Asthenopia patients were chosen from eleven hospitals cross China from July, 2008 to January, 2009. The experiment was conducted asthenopia patients who used the Esculin and Digitalis glycosides Eye Drops for 4 weeks continuously. Symptoms of asthenopia, UCVA (uncorrected vision acuity), refraction, amplitude of accommodation, accommodative lag, accommodative sensitivity and positive/negative relative accommodation were measured at different time points, such as treated before, 1 week and 4 week in treated after. After the 4-week's use of Esculin and Digitalis glycosides Eye Drops, each subjective symptom of the patients was decreased significantly (F=353.30, P<0.05). In addition, most of the objective exams of accommodation ability were significantly improved, such as UCVA (left eye: F=23.39, P<0.05; right eye: F=15.62, P<0.05), refraction (left eye: F=10.34, P<0.05; right eye: F=17.13, P<0.05), amplitude of accommodation (left eye: F=14.46, P<0.05; right eye: F=8.29, P<0.05; eyes: F=13.86, P<0.05), accommodative lag (F=14.89, P<0.05) and accommodative sensitivity (left eye: F=62.67, P<0.05; right eye: F=68.77, P<0.05; eyes: F=82.74, P<0.05). And no patient appeared any adverse reaction in whole experiment. Esculin and Digitalis glycosides Eye Drops is effective and safety for use in the patients of ametropia asthenopia.
Cohen, Michael N; Baumal, Caroline R
2018-05-10
To report early formation and spontaneous closure of a full-thickness macular hole that developed after successful pneumatic retinopexy in a patient who had been undergoing treatment for diabetic macular edema. Case report of a 68-year-old man with bilateral nonproliferative diabetic retinopathy who was currently undergoing anti-vascular endothelial growth factor treatment for bilateral diabetic macular edema. On presentation, visual acuity was 20/200 in the left eye, and examination revealed a bullous, macula-off retinal detachment with a single horseshoe tear at 12 o'clock in the left eye. Pneumatic retinopexy was performed followed by laser augmentation 3 days later. Three weeks postoperatively, he returned with visual acuity of 20/50 and a full-thickness macular hole in the left eye. Although he elected for initial observation, he returned 2 weeks later with visual acuity of 20/50 in both eyes and a retinal detachment with a single break at 10 o'clock in the right eye. The macular hole in the left eye had spontaneously resolved. Pneumatic retinopexy was performed to the right eye. Over 1 year after bilateral pneumatic retinopexy, his retina remains without recurrence of a macular hole in the left eye. In the early postoperative period after pneumatic retinopexy to repair a retinal detachment, a macular hole can form and spontaneously close.
Classical Pathology of Sympathetic Ophthalmia Presented in a Unique Case
Chen, Shida; Aronow, Mary E; Wang, Charles; Shen, Defen; Chan, Chi-Chao
2014-01-01
The ocular pathology of sympathetic ophthalmia is demonstrated in a 10 year-old boy who sustained a penetrating left globe injury and subsequently developed sympathetic ophthalmia in the right eye two months later. Two and a half weeks following extensive surgical repair of the left ruptured globe, he developed endophthalmitis and was treated with oral and topical fortified antibiotics. One month after the initial injury, a progressive corneal ulcer of the left eye led to perforation and the need for emergent corneal transplantation. The surgical specimen revealed fungus, Scedosporium dehoogii. The boy received systemic and topical anti-fungal therapy. Two months following the penetrating globe injury of the left eye, a granulomatous uveitis developed in the right eye. Sympathetic ophthalmia was suspected and the patient began treatment with topical and oral corticosteroids. Given the concern of vision loss secondary to sympathetic ophthalmia in the right eye, as well as poor vision and hypotony in the injured eye, the left eye was enucleated. Microscopically, granulomatous inflammation with giant cells was noted within a cyclitic membrane which filled the anterior and posterior chamber of the left globe. Other classic features including Dalen-Fuchs nodules were identified. Small, choroidal, ill-defined granulomas and relative sparing of the choriocapillaris were present. Molecular analysis did not identify evidence of remaining fungal infection. The pathology findings were consistent with previously described features of sympathetic ophthalmia. The present case is unique in that co-existing fungal infection may have potentiated the risk for developing sympathetic ophthalmia in the fellow eye. PMID:25067979
Immortal Ozurdex: A 10-month follow-up of an intralenticular implant.
Poornachandra, B; Kumar, Vinod B M; Jayadev, Chaitra; Dorelli, Subashchandra H; Yadav, Naresh Kumar; Shetty, Rohit
2017-03-01
A 78-year-old male who had received a dexamethasone implant (Ozurdex, Allergan, Inc., Irvine, CA, USA) 15 days back for recalcitrant diabetic macular edema in the left eye came to us for a second opinion. On examination, his corrected distance visual acuity was 20/20 in the right eye and 20/40 in the left eye. Early cataractous changes were present in both eyes. The intraocular pressure was within normal limits. The Ozurdex implant was seen lodged in the posterior cortex of the crystalline lens in the left eye, confirmed on anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy. Fundus examination showed moderate nonproliferative diabetic retinopathy in both eyes with macular edema and epiretinal membrane in the left eye, confirmed on OCT. The patient was noncompliant and returned after 10 months. Interestingly, the implant was still present in the same location with the same vision and anterior segment findings as before. The OCT showed a reduction in macular edema. The patient was advised regular follow-up and cataract surgery at a later date.
Left Limb of North Pole of the Sun, March 20, 2007
NASA Technical Reports Server (NTRS)
2007-01-01
[figure removed for brevity, see original site] [figure removed for brevity, see original site] Figure 1: Left eye view of a stereo pair Click on the image for full resolution TIFF Figure 2: Right eye view of a stereo pair Click on the image for full resolution TIFF Figure 1: This image was taken by the SECCHI Extreme UltraViolet Imager (EUVI) mounted on the STEREO-B spacecraft. STEREO-B is located behind the Earth, and follows the Earth in orbit around the Sun. This location enables us to view the Sun from the position of a virtual left eye in space. Figure 2: This image was taken by the SECCHI Extreme UltraViolet Imager (EUVI) mounted on the STEREO-A spacecraft. STEREO-A is located ahead of the Earth, and leads the Earth in orbit around the Sun, This location enables us to view the Sun from the position of a virtual right eye in space. NASA's Solar TErrestrial RElations Observatory (STEREO) satellites have provided the first three-dimensional images of the Sun. For the first time, scientists will be able to see structures in the Sun's atmosphere in three dimensions. The new view will greatly aid scientists' ability to understand solar physics and thereby improve space weather forecasting. The EUVI imager is sensitive to wavelengths of light in the extreme ultraviolet portion of the spectrum. EUVI bands at wavelengths of 304, 171 and 195 Angstroms have been mapped to the red blue and green visible portion of the spectrum; and processed to emphasize the temperature difference of the solar material. STEREO, a two-year mission, launched October 2006, will provide a unique and revolutionary view of the Sun-Earth System. The two nearly identical observatories -- one ahead of Earth in its orbit, the other trailing behind -- will trace the flow of energy and matter from the Sun to Earth. They will reveal the 3D structure of coronal mass ejections; violent eruptions of matter from the sun that can disrupt satellites and power grids, and help us understand why they happen. STEREO will become a key addition to the fleet of space weather detection satellites by providing more accurate alerts for the arrival time of Earth-directed solar ejections with its unique side-viewing perspective. STEREO is the third mission in NASA's Solar Terrestrial Probes program within NASA's Science Mission Directorate, Washington. The Goddard Science and Exploration Directorate manages the mission, instruments, and science center. The Johns Hopkins University Applied Physics Laboratory, Laurel, Md., designed and built the spacecraft and is responsible for mission operations. The imaging and particle detecting instruments were designed and built by scientific institutions in the U.S., UK, France, Germany, Belgium, Netherlands, and Switzerland. JPL is a division of the California Institute of Technology in Pasadena.75 FR 47883 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-09
... due to a traumatic injury sustained in 1996. The best corrected visual acuity in his right eye is 20... in a CMV. Benito Saldana Mr. Saldana, 52, has retinal detachment in his left eye due to a traumatic injury sustained in 1981. The best corrected visual acuity in his right eye is 20/20 and in his left eye...
Bilateral retinitis following Chikun- gunya fever
Murthy, Krishna R; Venkataraman, Nandita; Satish, Vidya
2008-01-01
A 35-year-old male with a history of chikungunya fever, presented with diminution of vision in the right eye of one-week duration. His best corrected visual acuity (BCVA) was counting fingers 2 meters and 20/20 (Snellens) in the right and left eyes respectively. A diagnosis of neuroretinitis was made in the right eye while left eye showed features of retinitis. ELISA (serum) and polymerase chain reaction (aqueous) were positive for herpes simplex virus. The lesions did not show any response to antiviral or steroid treatment and appeared to be self-limiting. At five months follow-up, lesions had resolved well with BCVA of 20/120 and 20/20 in the right and left eyes respectively. PMID:18579997
Design of a Gaze-Sensitive Virtual Social Interactive System for Children With Autism
Lahiri, Uttama; Warren, Zachary; Sarkar, Nilanjan
2013-01-01
Impairments in social communication skills are thought to be core deficits in children with autism spectrum disorder (ASD). In recent years, several assistive technologies, particularly Virtual Reality (VR), have been investigated to promote social interactions in this population. It is well known that children with ASD demonstrate atypical viewing patterns during social interactions and thus monitoring eye-gaze can be valuable to design intervention strategies. While several studies have used eye-tracking technology to monitor eye-gaze for offline analysis, there exists no real-time system that can monitor eye-gaze dynamically and provide individualized feedback. Given the promise of VR-based social interaction and the usefulness of monitoring eye-gaze in real-time, a novel VR-based dynamic eye-tracking system is developed in this work. This system, called Virtual Interactive system with Gaze-sensitive Adaptive Response Technology (VIGART), is capable of delivering individualized feedback based on a child’s dynamic gaze patterns during VR-based interaction. Results from a usability study with six adolescents with ASD are presented that examines the acceptability and usefulness of VIGART. The results in terms of improvement in behavioral viewing and changes in relevant eye physiological indexes of participants while interacting with VIGART indicate the potential of this novel technology. PMID:21609889
Design of a gaze-sensitive virtual social interactive system for children with autism.
Lahiri, Uttama; Warren, Zachary; Sarkar, Nilanjan
2011-08-01
Impairments in social communication skills are thought to be core deficits in children with autism spectrum disorder (ASD). In recent years, several assistive technologies, particularly Virtual Reality (VR), have been investigated to promote social interactions in this population. It is well known that children with ASD demonstrate atypical viewing patterns during social interactions and thus monitoring eye-gaze can be valuable to design intervention strategies. While several studies have used eye-tracking technology to monitor eye-gaze for offline analysis, there exists no real-time system that can monitor eye-gaze dynamically and provide individualized feedback. Given the promise of VR-based social interaction and the usefulness of monitoring eye-gaze in real-time, a novel VR-based dynamic eye-tracking system is developed in this work. This system, called Virtual Interactive system with Gaze-sensitive Adaptive Response Technology (VIGART), is capable of delivering individualized feedback based on a child's dynamic gaze patterns during VR-based interaction. Results from a usability study with six adolescents with ASD are presented that examines the acceptability and usefulness of VIGART. The results in terms of improvement in behavioral viewing and changes in relevant eye physiological indexes of participants while interacting with VIGART indicate the potential of this novel technology. © 2011 IEEE
Art in the eye of the beholder: the perception of art during monocular viewing.
Finney, Glen Raymond; Heilman, Kenneth M
2008-03-01
To explore whether monocular viewing affects judgment of art. Each superior colliculus receives optic nerve fibers primarily from the contralateral eye, and visual input to each colliculus activates the ipsilateral hemisphere. In previous studies, monocular viewing influenced performance on visual-spatial and verbal memory tasks. Eight college-educated subjects, 6 men and 2 women, monocularly viewed 10 paintings with the right eye and another 10 with the left. Subjects had not previously seen the paintings. Each time, 5 paintings were abstract expressionist and 5 were impressionist. The orders of eye viewing and painting viewed were pseudorandomized and counterbalanced. Subjects rated on a 1 to 10 scale 4 qualities of the paintings: representation, aesthetics (beauty), novelty, and closure (completeness). Paintings in the abstract expressionist style had a significant difference in the rating of novelty; the paintings were rated more novel when viewed with the left eye than with the right eye. There was a trend for rating paintings as having more closure when viewing with the right eye than with the left. Impressionist paintings show no differences. Monocular viewing influences artistic judgments; novelty being rated higher when viewed with the left eye. Asymmetric projections from each eye and hemispheric specialization are posited to explain these differences.
75 FR 26968 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel; NEI Loan Repayment... applications. Place: National Eye Institute, 5635 Fishers Lane, Bethesda, MD (Virtual Meeting). Contact Person...
Human agency beliefs influence behaviour during virtual social interactions
Brock, Jon
2017-01-01
In recent years, with the emergence of relatively inexpensive and accessible virtual reality technologies, it is now possible to deliver compelling and realistic simulations of human-to-human interaction. Neuroimaging studies have shown that, when participants believe they are interacting via a virtual interface with another human agent, they show different patterns of brain activity compared to when they know that their virtual partner is computer-controlled. The suggestion is that users adopt an “intentional stance” by attributing mental states to their virtual partner. However, it remains unclear how beliefs in the agency of a virtual partner influence participants’ behaviour and subjective experience of the interaction. We investigated this issue in the context of a cooperative “joint attention” game in which participants interacted via an eye tracker with a virtual onscreen partner, directing each other’s eye gaze to different screen locations. Half of the participants were correctly informed that their partner was controlled by a computer algorithm (“Computer” condition). The other half were misled into believing that the virtual character was controlled by a second participant in another room (“Human” condition). Those in the “Human” condition were slower to make eye contact with their partner and more likely to try and guide their partner before they had established mutual eye contact than participants in the “Computer” condition. They also responded more rapidly when their partner was guiding them, although the same effect was also found for a control condition in which they responded to an arrow cue. Results confirm the influence of human agency beliefs on behaviour in this virtual social interaction context. They further suggest that researchers and developers attempting to simulate social interactions should consider the impact of agency beliefs on user experience in other social contexts, and their effect on the achievement of the application’s goals. PMID:28948104
Influence of virtual reality on postural stability during movements of quiet stance.
Horlings, Corinne G C; Carpenter, Mark G; Küng, Ursula M; Honegger, Flurin; Wiederhold, Brenda; Allum, John H J
2009-02-27
Balance problems during virtual reality (VR) have been mentioned in the literature but seldom investigated despite the increased use of VR systems as a training or rehabilitation tool. We examined the influence of VR on body sway under different stance conditions. Seventeen young subjects performed four tasks (standing with feet close together or tandem stance on firm and foam surfaces for 60s) under three visual conditions: eyes open without VR, eyes closed, or while viewing a virtual reality scene which moved with body movements. Angular velocity transducers mounted on the shoulder provided measures of body sway in the roll and pitch plane. VR caused increased pitch and roll angles and angular velocities compared to EO. The effects of VR were, for the most part, indistinguishable from eyes closed conditions. Use of a foam surface increased sway compared to a firm surface under eyes closed and VR conditions. During the movements of quiet stance, VR causes an increase in postural sway in amplitude similar to that caused by closing the eyes. This increased sway was present irrespective of stance surface, but was greatest on foam.
Wu, Chris Y; Jansen, Michael E; Andrade, Jorge; Chui, Toco Y P; Do, Anna T; Rosen, Richard B; Deobhakta, Avnish
2018-01-01
Solar retinopathy is a rare form of retinal injury that occurs after direct sungazing. To enhance understanding of the structural changes that occur in solar retinopathy by obtaining high-resolution in vivo en face images. Case report of a young adult woman who presented to the New York Eye and Ear Infirmary with symptoms of acute solar retinopathy after viewing the solar eclipse on August 21, 2017. Results of comprehensive ophthalmic examination and images obtained by fundus photography, microperimetry, spectral-domain optical coherence tomography (OCT), adaptive optics scanning light ophthalmoscopy, OCT angiography, and en face OCT. The patient was examined after viewing the solar eclipse. Visual acuity was 20/20 OD and 20/25 OS. The patient was left-eye dominant. Spectral-domain OCT images were consistent with mild and severe acute solar retinopathy in the right and left eye, respectively. Microperimetry was normal in the right eye but showed paracentral decreased retinal sensitivity in the left eye with a central absolute scotoma. Adaptive optics images of the right eye showed a small region of nonwaveguiding photoreceptors, while images of the left eye showed a large area of abnormal and nonwaveguiding photoreceptors. Optical coherence tomography angiography images were normal in both eyes. En face OCT images of the right eye showed a small circular hyperreflective area, with central hyporeflectivity in the outer retina of the right eye. The left eye showed a hyperreflective lesion that intensified in area from inner to middle retina and became mostly hyporeflective in the outer retina. The shape of the lesion on adaptive optics and en face OCT images of the left eye corresponded to the shape of the scotoma drawn by the patient on Amsler grid. Acute solar retinopathy can present with foveal cone photoreceptor mosaic disturbances on adaptive optics scanning light ophthalmoscopy imaging. Corresponding reflectivity changes can be seen on en face OCT, especially in the middle and outer retina. Young adults may be especially vulnerable and need to be better informed of the risks of viewing the sun with inadequate protective eyewear.
Yücel, Yeni H; Cardinell, Kirsten; Khattak, Shireen; Zhou, Xun; Lapinski, Michael; Cheng, Fang; Gupta, Neeru
2018-06-01
To visualize and quantify lymphatic drainage of aqueous humor from the eye to cervical lymph nodes in the dynamic state. A near-infrared tracer was injected into the right eye anterior chamber of 10 mice under general anesthesia. Mice were imaged with photoacoustic tomography before and 20 minutes, 2, 4, and 6 hours after injection. Tracer signal intensity was measured in both eyes and right and left neck lymph nodes at every time point and signal intensity slopes were calculated. Slope differences between right and left eyes and right and left nodes were compared using paired t-test. Neck nodes were examined with fluorescence optical imaging and histologically for the presence of tracer. Following right eye intracameral injection of tracer, an exponential decrease in tracer signal was observed from 20 minutes to 6 hours in all mice. Slope differences of the signal intensity between right and left eyes were significant (P < 0.001). Simultaneously, increasing tracer signal was observed in the right neck node from 20 minutes to 6 hours. Slope differences of the signal intensity between right and left neck nodes were significant (P = 0.0051). Ex vivo optical fluorescence imaging and histopathologic examination of neck nodes confirmed tracer presence within submandibular nodes. Active lymphatic drainage of aqueous from the eye to cervical lymph nodes was measured noninvasively by photoacoustic imaging of near-infrared nanoparticles. This unique in vivo assay may help to uncover novel drugs that target alternative outflow routes to lower IOP in glaucoma and may provide new insights into lymphatic drainage in eye health and disease.
Could Buerger's disease cause nonarteritic anterior ischemic optic neuropathy?: a rare case report.
Korkmaz, Anil; Karti, Omer; Top Karti, Dilek; Yüksel, Bora; Zengin, Mehmet Ozgur; Kusbeci, Tuncay
2018-04-05
We present an interesting case with nonarteritic anterior ischemic optic neuropathy (NAION) accompanied by Buerger's disease. A 43-year-old man was referred to our neuro-ophthalmology clinic with a complaint of visual deterioration in the left eye that started 5 days ago. He suffered from Buerger's disease, and he had acute pain in the right lower limb below the knee. His best corrected visual acuity was 10/10 in the right eye and 2/10 in the left eye by Snellen chart. There was a relative afferent pupil defect in the left eye. The right optic disc was normal on fundus examination, and blurring, hemorrhagic swelling was found at the left optic disc. Inferior altitudinal visual field defect was observed in the left eye. Neurological examination was normal. Computed tomography angiography scan revealed occlusion in the right posterior tibial artery. Brain imaging and laboratory tests such as blood analyses, genetic screening, coagulation, and lipid panels were unremarkable. NAION may occur in patients with Buerger's disease, but it is extremely rare. Therefore, clinicians should be aware of this rare association.
76 FR 3917 - National Eye Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-21
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Training Grants. Date...: National Eye Institute, 5635 Fishers Lane, Rockville, MD 20852 (Virtual Meeting). Contact Person: Daniel R...
Huge corneal dermoid in a well-formed eye: a case report and review of the literature.
Mohammad, Abd-Elnasser A; Kroosh, Sana S
2002-12-01
A 25-day-old boy presented with a left corneal mass and left nasal obstruction. The mass involved the entire cornea with a skin-like surface and protruded outside the palpebral fissure. CT of the orbits disclosed a large cyst coating the entire left cornea, in an eye with a well-formed anterior chamber and a clearly evident lens. CT also revealed left nasal meningo-encephalocele. The eye with the mass was excised. The histopathologic report confirmed the diagnosis of corneal dermoid in an otherwise normally developed eye. This report of a huge dermoid involving the entire corneal diameter and extending into the sclera without ocular alteration posterior to Descemet's membrane is the first such report in the literature. The literature on corneal dermoids is also reviewed.
Bilateral Coats' Disease Combined with Retinopathy of Prematurity
Gursoy, Huseyin; Erol, Nazmiye; Bilgec, Mustafa Deger; Basmak, Hikmet; Kutlay, Ozden; Aslan, Huseyin
2015-01-01
Purpose. To report a case of bilateral Coats' disease combined with retinopathy of prematurity (ROP). Case. Retinal vascularization was complete in the right eye, whereas zone III, stage 3 ROP and preplus disease were observed in the left eye at 43 weeks of postmenstrual age (PMA) in a 31-week premature, 1200-g neonate. Intraretinal exudates developed and retinal hemorrhages increased in the left eye at 51 weeks of PMA. Diode laser photocoagulation (LP) was applied to the left eye. Exudates involved the macula, and telangiectatic changes developed one month following LP. Additional LP was applied to the left eye combined with intravitreal bevacizumab (IVB) injection at 55 weeks of PMA. Disease regressed one month after the additional therapy. At the 14-month examination of the baby, telangiectatic changes and intraretinal exudates were observed in the right eye. Diode LP was applied to the right eye combined with IVB injection. Exudates did not resolve completely, and cryotherapy was applied one month following LP. Retinal findings regressed three months following the cryotherapy. Conclusion. This is the first report of presumed bilateral Coats' disease combined with ROP. If Coats' disease could be diagnosed at early stages, it would be a disease associated with better prognosis. PMID:26413362
Case report: imaging and treatment of ophthalmic manifestations in oculodentodigital dysplasia.
Mosaed, Sameh; Jacobsen, Bradley H; Lin, Ken Young
2016-01-07
Diagnostic and surgical management of severe chronic angle- closure glaucoma secondary to ciliary body cysts can be difficult to manage in a patient with oculodentodigital dysplasia. A 6-year old girl with oculodentodigital dysplasia, with progressive chronic angle- closure glaucoma secondary to ciliary body cysts presented to our clinic. The initial examination revealed counting fingers vision in the left eye. Intraocular pressure (IOP), as assessed by tonopen, was 31 mm Hg. Ultrasound biomicroscopy revealed ciliary body cysts in the left eye, and gonioscopy confirmed chronic angle closure. A tube shunt was placed to control the elevated IOP. A year after her tube shunt placement in the left eye, ultrasound biomiscropy was performed on her right eye and showed no ciliary body cysts. Gonioscopy in the right eye revealed an open angle to the ciliary body band. Subsequent serial gonioscopy every 3 months showed gradual narrowing of the right eye angle and finally three-and-a-half years after tube placement of the left eye, her right eye IOP became uncontrolled with medications alone and a tube shunt was similarly placed in the right eye. Intraoperative ultrasound biomicroscopy performed at the time of the right eye tube shunt revealed extensive ciliary body cysts in the right eye. Her IOP in both eyes have been well controlled since the placement of tube shunts. This is one of the first reported cases of severe chronic angle- closure glaucoma secondary to ciliary body cysts in a patient with oculodentodigital dysplasia. We believe that early screening for ciliary body cysts is important in patients with oculodentodigital dysplasia.
75 FR 9480 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-02
.... Buchanan, 56, has a prosthetic left eye due to a traumatic injury sustained in 1961. The best corrected... prosthetic right eye due to a traumatic injury sustained at age 12. The best corrected visual acuity in his..., has a prosthetic left eye due to a traumatic injury sustained during childhood. The best corrected...
Unilateral pigmentary degeneration of the retina associated with heterochromia iridis.
Grisanti, S; Diestelhorst, M; Lebek, J; Walter, P; Heimann, K
1998-12-01
For the past 5 years, a 56-year-old patient has been displaying monocular progressive pigmentary changes in the left eye. Heterochromy of the left eye has been known since childhood. The other eye is clinically and functionally normal. The patient was adopted and he has no children. Therefore, we have no family history. The patient was examined clinically and by means of electroretinography, electrooculography, perimetry, computer tomography, pulsatile ocular blood flow (POBF) measurement, serology and Doppler sonography. Electrophysiology displayed a considerable reduction of scotopic and photopic ERGs, a reduced dark-through, and a reduced light-rise in the left eye, whereas the fellow eye was normal. The visual field was limited to 5 deg around the fixation point, and a peripheral crescent-shaped arch encircled the temporal-inferior quadrant concomitant to the pigmentary changes. By computer tomography and Doppler sonography a vascular affection was excluded. The left eye displayed lower POBF values. All serological tests were found negative. The clinical picture and negative exclusion criteria indicate a unilateral retinitis pigmentosa. However, with regard to the literature an unequivocal diagnosis can only be made upon hereditary evidence.
A case of unilateral phthiriasis palpebrarum infestation involving the left eye.
Ashraf, Mohammad; Waris, Abdul; Kumar, Ashwini; Akhtar, Nahid
2014-06-06
Phthiriasis palpebrarum is a rare cause of eyelid infestation. We report a case of unilateral phthiriasis palpebrarum. A 28-year-old man presented with moderate itching associated with lacrimation and irritation in the left eye. The initial evaluation of the patient revealed multiple white dots on the left upper eyelashes. Slit-lamp examination revealed multiple nits attached to the base and shaft of the cilia. There was no hyperaemia or discharge present in the conjunctiva and the cornea was clear and shiny. The right eye was perfectly normal. The patient was treated with moxifloxacin eye ointment and was completely cured in 1 week. 2014 BMJ Publishing Group Ltd.
Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu
2014-01-01
A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.
Language-driven anticipatory eye movements in virtual reality.
Eichert, Nicole; Peeters, David; Hagoort, Peter
2018-06-01
Predictive language processing is often studied by measuring eye movements as participants look at objects on a computer screen while they listen to spoken sentences. This variant of the visual-world paradigm has revealed that information encountered by a listener at a spoken verb can give rise to anticipatory eye movements to a target object, which is taken to indicate that people predict upcoming words. The ecological validity of such findings remains questionable, however, because these computer experiments used two-dimensional stimuli that were mere abstractions of real-world objects. Here we present a visual-world paradigm study in a three-dimensional (3-D) immersive virtual reality environment. Despite significant changes in the stimulus materials and the different mode of stimulus presentation, language-mediated anticipatory eye movements were still observed. These findings thus indicate that people do predict upcoming words during language comprehension in a more naturalistic setting where natural depth cues are preserved. Moreover, the results confirm the feasibility of using eyetracking in rich and multimodal 3-D virtual environments.
Brain Activity on Navigation in Virtual Environments.
ERIC Educational Resources Information Center
Mikropoulos, Tassos A.
2001-01-01
Assessed the cognitive processing that takes place in virtual environments by measuring electrical brain activity using Fast Fourier Transform analysis. University students performed the same task in a real and a virtual environment, and eye movement measurements showed that all subjects were more attentive when navigating in the virtual world.…
Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq
2018-04-26
An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.
Circumferential Ciliary Body Cysts Presenting as Acute Pigment Dispersion and Ocular Hypertension.
Sarıgül Sezenöz, Almila; Güngör, Sirel Gür; Kıratlı, Hayyam; Akman, Ahmet
2017-09-15
To report a case of circumferential neuroepithelial cyst of the ciliary body presenting with pigment dispersion (PD) and ocular hypertension. 48-year-old female patient presented with a complaint of pain in the left eye. On examination, visual acuity of the left eye was 0.9, and the intraocular pressure was 48 mmHg. Biomicroscopic anterior segment examination of the left eye revealed 4+ pigmented cells in the anterior chamber. Active PD from the pupillary region at 11 o'clock was noticed at the time of the examination. Ultrasound biomicroscopy demonstrated 360º cystic lesions of the ciliary body in the left eye. The patient was diagnosed as neuroepithelial cyst of the ciliary body. Our case is unique as it is the first case of circumferential neuroepithelial ciliary body cyst presenting with acute PD and ocular hypertension.
Intraocular pressure in clinically normal dromedary camels (Camelus dromedarius).
Marzok, Mohamed A; El-Khodery, Sabry A
2015-02-01
To determine the intraocular pressure (IOP) in healthy dromedary camels (Camelus dromedarius). 24 clinically normal dromedary camels. For each camel, the IOP of both eyes was measured with applanation tonometry. Three measurements with < 5% variance were obtained for each eye on the same day of the week for 3 consecutive weeks. Mean IOP was calculated for each eye on each day for comparison purposes. Mean ± SD IOPs for the right (31.1 ± 2.1 mm Hg) and left (30.8 ± 1.9 mm Hg) eyes of immature camels were significantly higher than those for the right (27.1 ± 1.2 mm Hg) and left (28.2 ± 1.2 mm Hg) eyes of mature camels. Intra-assay and interassay coefficients of variation (CVs) for IOP measurements of the right and left eyes did not differ significantly between immature and mature camels. Interassay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 12.1% and 1.2% to 10.3%, respectively, for immature camels and from 1.2% to 17.2% and 1.7% to 18.8%, respectively, for mature camels. Intra-assay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 10.6% and 1.9% to 9.6%, respectively, for immature camels and from 2.8% to 16.9% and 2.7% to 12.4%, respectively, for mature camels. Age was negatively correlated (r = -0.403) with IOP. Results provided a reference and might aid in the diagnosis of glaucoma and uveitis during complete ophthalmic examinations of dromedary camels.
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Schuman, Joel S
2016-01-01
Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t -test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects.
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Schuman, Joel S.
2016-01-01
Purpose Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. Results All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t-test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. Conclusion The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Translational Relevance Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects. PMID:26835180
77 FR 19749 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-02
... optic nerve in his right eye due to a traumatic injury sustained in 1995. The best corrected visual.... Clark Mr. Clark, 66, has a detached retina in his left eye due to a traumatic injury sustained in 1967... a traumatic injury sustained as a child. The best corrected visual acuity in his left eye is 20/20...
76 FR 64169 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-17
... detachment in his left eye due to a traumatic injury that occurred in 1982. The best corrected visual acuity... traumatic injury sustained in 2000. The best corrected visual acuity in his right eye is 20/30. Following an... to an injury sustained in 1976. The best corrected visual acuity in his left eye is 20/15. Following...
76 FR 55465 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-07
... enucleation of his left eye due to a traumatic injury that he sustained in 1952. The best corrected visual... due to a traumatic injury that occurred in 1983. The best corrected visual acuity in his right eye is... Mr. Buckingham, 43, has a prosthetic left eye due to a traumatic injury that occurred more than 25...
77 FR 33017 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-04
... complete loss of vision in his left eye due to a traumatic injury sustained at age 29. The best corrected... traumatic injury sustained in 1981. The best corrected visual acuity in his right eye is finger count vision... left eye due to a traumatic incident sustained 25 years ago. The best corrected visual acuity in his...
75 FR 77942 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-14
... traumatic injury sustained as a child. The best corrected visual acuity in his right eye is no light.... Shaver, 57, has had traumatic neuropathy in his left eye since childhood due to an injury. The best.... Smith Mr. Smith, 57, has had complete loss of vision in his left eye due to a traumatic injury sustained...
How virtual reality works: illusions of vision in "real" and virtual environments
NASA Astrophysics Data System (ADS)
Stark, Lawrence W.
1995-04-01
Visual illusions abound in normal vision--illusions of clarity and completeness, of continuity in time and space, of presence and vivacity--and are part and parcel of the visual world inwhich we live. These illusions are discussed in terms of the human visual system, with its high- resolution fovea, moved from point to point in the visual scene by rapid saccadic eye movements (EMs). This sampling of visual information is supplemented by a low-resolution, wide peripheral field of view, especially sensitive to motion. Cognitive-spatial models controlling perception, imagery, and 'seeing,' also control the EMs that shift the fovea in the Scanpath mode. These illusions provide for presence, the sense off being within an environment. They equally well lead to 'Telepresence,' the sense of being within a virtual display, especially if the operator is intensely interacting within an eye-hand and head-eye human-machine interface that provides for congruent visual and motor frames of reference. Interaction, immersion, and interest compel telepresence; intuitive functioning and engineered information flows can optimize human adaptation to the artificial new world of virtual reality, as virtual reality expands into entertainment, simulation, telerobotics, and scientific visualization and other professional work.
Kaarthigeyan, J; Dharmaretnam, Meena
2005-04-15
Cerebral lateralisation once thought to be confined to humans has been reported for a range of vertebrate species now. We report here biases in visual perceptual processing in a teleost fish. Female guppy fish used the right eye preferentially to view a familiar stimulus. This bias reversed on being presented with a strange female guppy, the left eye being used more to view it. This pattern of viewing is probably associated with the right eye system, which is used to view a stimulus with an intention to approach it. The increase in the left eye use, to view a stranger may be associated with the role of the left eye in comparing the features of a strange conspecific. In the second experiment, lateralisation of viewing visual stimuli that could evoke different levels of motivation to biologically relevant stimuli was tested. It is known that female guppies prefer to approach orange coloured males. Lateralisation of detour response as well as eye use after detour to view a dull or an orange male stimulus was recorded in deprived female fish. There was a bias to detour to the left side; which was more significant for the orange than the dull male. Once the female guppies detoured the cage they preferentially used the left eye to view the male conspecific; this being significant for the deeply orange male. Thus, colouration of males evoking different levels motivation can be used to measure lateralisation in guppies.
Kim, Hee-Kyoung; Min, Kyoung-Ok; Choi, Jung-Hyun; Kim, Soon-Hee
2016-01-01
[Purpose] In this study, the effects of low-level laser therapy (LLLT), electroacupuncture (EA), and radiofrequency (RF), which are used in physical therapy, on the pigmentation and skin tone of adult women’s faces were investigated to provide basic data for skin interventions. [Subjects and Methods] Thirty adult females were assigned to either an LLLT group (n=10), an EA group (n=10), or an RF group (n=10). The intervention was performed in two 15-minute sessions per week for six weeks. Subjects’ skin tone and pigmentation were observed before and after the intervention. [Results] The EA group showed significant reductions in pigmentation in the left and right eye rims, as well as in the left cheek. The RF group showed significant post-intervention reductions in pigmentation under the left eye, as well as in the left and right eye rims and the left cheek. The LLLT group showed significant increases in skin tone in the forehead and both eye rims. The RF group showed significant increases in skin tone under both eyes. [Conclusion] The application of LLLT, EA, and RF had positive effects on pigmentation and skin tone of adult women’s faces. PMID:27313340
Eye Gaze Correlates of Motor Impairment in VR Observation of Motor Actions.
Alves, J; Vourvopoulos, A; Bernardino, A; Bermúdez I Badia, S
2016-01-01
This article is part of the Focus Theme of Methods of Information in Medicine on "Methodologies, Models and Algorithms for Patients Rehabilitation". Identify eye gaze correlates of motor impairment in a virtual reality motor observation task in a study with healthy participants and stroke patients. Participants consisted of a group of healthy subjects (N = 20) and a group of stroke survivors (N = 10). Both groups were required to observe a simple reach-and-grab and place-and-release task in a virtual environment. Additionally, healthy subjects were required to observe the task in a normal condition and a constrained movement condition. Eye movements were recorded during the observation task for later analysis. For healthy participants, results showed differences in gaze metrics when comparing the normal and arm-constrained conditions. Differences in gaze metrics were also found when comparing dominant and non-dominant arm for saccades and smooth pursuit events. For stroke patients, results showed longer smooth pursuit segments in action observation when observing the paretic arm, thus providing evidence that the affected circuitry may be activated for eye gaze control during observation of the simulated motor action. This study suggests that neural motor circuits are involved, at multiple levels, in observation of motor actions displayed in a virtual reality environment. Thus, eye tracking combined with action observation tasks in a virtual reality display can be used to monitor motor deficits derived from stroke, and consequently can also be used for rehabilitation of stroke patients.
McFarlane, N. J. B.; Lin, X.; Zhao, Y.; Clapworthy, G. J.; Dong, F.; Redaelli, A.; Parodi, O.; Testi, D.
2011-01-01
Ischaemic heart failure remains a significant health and economic problem worldwide. This paper presents a user-friendly software system that will form a part of the virtual pathological heart of the Virtual Physiological Human (VPH2) project, currently being developed under the European Commission Virtual Physiological Human (VPH) programme. VPH2 is an integrated medicine project, which will create a suite of modelling, simulation and visualization tools for patient-specific prediction and planning in cases of post-ischaemic left ventricular dysfunction. The work presented here describes a three-dimensional interactive visualization for simulating left ventricle restoration surgery, comprising the operations of cutting, stitching and patching, and for simulating the elastic deformation of the ventricle to its post-operative shape. This will supply the quantitative measurements required for the post-operative prediction tools being developed in parallel in the same project. PMID:22670207
Romano, Mary; Iacovello, Daniela; Cascone, Nikhil C; Contestabile, Maria Teresa
2011-01-01
To document the clinical, functional, and in vivo microanatomic characteristics of a patient with Gorlin-Goltz syndrome with a novel nonsense mutation in PTCH (patched). Optical coherence tomography (OCT), fluorescein angiography, electrophysiologic testing, visual field, magnetic resonance imaging, and mutation screening of PTCH gene. Visual acuity was 20/20 in the right eye and 20/25 in the left. Fundus examination revealed myelinated nerve fibers in the left eye and bilateral epiretinal membranes with lamellar macular hole also documented with macular OCT. A reduction of the retinal nerve fiber layers in both eyes was found with fiber nervous OCT. Fluorescein angiography showed bilaterally foveal hyperfluorescence and the visual field revealed inferior hemianopia in the right eye. Pattern visual evoked potentials registered a reduction of amplitude in both eyes and latency was delayed in the left eye. Pattern electroretinogram showed a reduction in P50 and N95 peak time and a delay in P50 peak time in the left eye. Flash electroretinogram was reduced in rod response, maximal response, and oscillatory potentials in both eyes. Cone response was normal and 30-Hz flicker was slightly reduced in both eyes. Mutation screening identified a novel nonsense mutation in PTCH. A novel nonsense mutation in the PTCH gene was found. We report the occurrence of epiretinal membranes and the persistence of myelinated nerve fibers. Electrophysiologic and visual field alterations, supporting a neuroretinal dysfunction, were also documented.
Isolated eyeball metastasis of non-seminomatous germ cell testicular tumor.
Bojanić, Nebojsa; Nale, Djordje; Mićić, Sava; Janicić, Aleksandar; Vuksanović, Aleksandar; Vuković, Ivan
2011-11-01
Testicular tumors most frequently metastasize to regional lymph nodes. Non-seminomatous tumor metastasis of testicle (NSGCTT) to the eyeball is rare. We presented a 24-year old man, referred to the ophthalmologist due to acute pain and abrupt loss of sight in the left eye accompanied by its enlargement. Orbital and endocranial computerized tomography (CT) was carried out, indicating the tumor in the left eye. His previous medical history provided the information that the right testicle was painlessly enlarged for 8 months. Ultrasonography showed a completely tumorously altered testis. Abdominal and chest CT failed to reveal any secondary deposits in visceral organs and lymph glands. Tumor markers (AFP - alpha-fetoproteins, beta hCG - human choronic gonadotropin beta) were elevated. Right radical orchiactomy was performed (showed NSGCTT), followed by polychemotherapy with cisplatinum 100 mg/m2, etoposide 120 mg/m2, bleomycin 15 mg/m2 (PEB x 4), resulting in normalization of tumor marker values and significant regression of the left eyeball. Next, the left eye enucleation and ocular prosthesis implantation was carried out. Pathohistological evaluation indicated fibrosis and necrosis only. In a 5-year follow-up period, the patient was free of recurrence. Isolated hematogenous metastasis of the NSGCTT to the eye is rare. In our case, the left eye was the only metastatic localization. After chemotherapy and eye enucleation the patient was in a 4-year follow-up period free of the recurrence.
76 FR 25764 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... macular scar in his left eye due to a traumatic injury sustained as a child. The best corrected visual... traumatic injury that occurred in 1976. The best corrected visual acuity in his right eye is 20/20 and in.... Lightner Mr. Lightner, 60, has loss of vision in his left eye due to a traumatic injury sustained at age 3...
Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.
Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr
2014-03-01
In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.
Enucleation in a Cownose Ray (Rhinoptera bonasus)
Yee-Nin, S. T.; Hassan, H. M. D.; Wahid, A. H.
2018-01-01
Trauma is a common problem in Cownose Ray during mating season in both wild and captive rays. Enucleation is indicated when there is an ocular trauma. A 5-year-old female Cownose Ray (Rhinoptera bonasus) from Aquaria of Kuala Lumpur Convention Centre (KLCC) was presented to University Veterinary Hospital (UVH), Universiti Putra Malaysia, with a complaint of protruding left eye, which resulted from crushing into artificial coral during mating season. There were a hyphema in the traumatic left eye, periorbital tissue tear, exposed left eye socket, and multiple abrasions on both pectoral fins. The Cownose was anaesthetized and maintained with isoeugenol and on-field emergency enucleation of the left eye was performed. It was managed medically with postoperative enrofloxacin, tobramycin ointment, and povidone iodine. No suture breakdown and secondary infection were observed at day 7 after enucleation during revisit. At day 24 after enucleation, the Cownose responded well to treatment with excellent healing progression and no surgical complication was observed.
Eye position changes during reading fixations are spatially selective.
Inhoff, Albrecht W; Solomon, Matthew S; Seymour, Bradley A; Radach, Ralph
2008-03-01
Intra-fixation location changes were measured when one-line sentences written in lower or aLtErNaTiNg case were read. Intra-fixation location changes were common and their size was normally distributed except for a relatively high proportion of fixations without a discernible location change. Location changes that did occur were systematically biased toward the right when alternating case was read. Irrespective of case type, changes of the right eye were biased toward the right at the onset of sentence reading, and this spatial bias decreased as sentence reading progressed from left to right. The left eye showed a relatively stable right-directed bias. These results show that processing demands can pull the two fixated eyes in the same direction and that the response to this pull can differ for the right and left eye.
Asymmetric severity of diabetic retinopathy in Waardenburg syndrome.
Kashima, Tomoyuki; Akiyama, Hideo; Kishi, Shoji
2011-01-01
A 30-year-old female patient was referred to our institution due to vitreous hemorrhage. Best corrected visual acuity of her right and left eyes at her initial visit was 10/20 and 20/20, respectively. Although hypochromic iris was observed in the superior iris between the 10 and 2 o'clock positions in her right eye, her entire left eye exhibited hypochromic iris. Hypopigmentation of the fundus was seen in the superior part of her right eye. This eye also had a huge neovascularization on the optic disc that was 7 discs in diameter. Conversely, her left fundi showed hypopigmentation of the fundus in the entire region of the left eye, and dot hemorrhages were observed all over the left fundi, although no neovascularization could be seen microscopically. Fluorescein angiography showed a huge neovascularization in the right eye and a tiny neovascularization in the left eye. Gene analysis revealed the presence of the PAX3 gene homeobox domain mutation, which led to her being diagnosed as Waardenburg syndrome type 1. Magnetic resonance angiography showed there was no obstructive region at either of the internal carotid arteries and ophthalmic arteries. The severity of the diabetic retinopathy appeared to be correlated with the degree of hypopigmentation in the posterior fundus. We speculate that hypopigmentation of the fundus in Waardenburg syndrome may be responsible for the reduction in retinal metabolism, which led to a reduction in oxygen consumption and prevented further aggravation of the diabetic retinopathy. Only laser treatments using short wavelengths was effective in this case. While the extinction coefficient for hemoglobin when using green light is higher than when using yellow light, the differences between these wavelengths tend to disappear when oxygenated hemoglobin is present. To the best of the authors' knowledge, this is the first case report of a patient with Waardenburg syndrome and diabetic retinopathy.
Motion sickness and proprioceptive aftereffects following virtual environment exposure
NASA Technical Reports Server (NTRS)
Stanney, K. M.; Kennedy, R. S.; Drexler, J. M.; Harm, D. L.
1999-01-01
To study the potential aftereffects of virtual environments (VE), tests of visually guided behavior and felt limb position (pointing with eyes open and closed) along with self-reports of motion sickness-like discomfort were administered before and after 30 min exposure of 34 subjects. When post- discomfort was compared to a pre-baseline, the participants reported more sickness afterward (p < 0.03). The change in felt limb position resulted in subjects pointing higher (p < 0.038) and slightly to the left, although the latter difference was not statistically significant (p = 0.08). When findings from a second study using a different VE system were compared, they essentially replicated the results of the first study with higher sickness afterward (p < 0.001) and post- pointing errors were also up (p < 0.001) and to the left (p < 0.001). While alternative explanations (e.g. learning, fatigue, boredom, habituation, etc.) of these outcomes cannot be ruled out, the consistency of the post- effects on felt limb position changes in the two VE implies that these recalibrations may linger once interaction with the VE has concluded, rendering users potentially physiologically maladapted for the real world when they return. This suggests there may be safety concerns following VE exposures until pre-exposure functioning has been regained. The results of this study emphasize the need for developing and using objective measures of post-VE exposure aftereffects in order to systematically determine under what conditions these effects may occur.
Eye gazing direction inspection based on image processing technique
NASA Astrophysics Data System (ADS)
Hao, Qun; Song, Yong
2005-02-01
According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.
CONCOMITANT MACULAR HOLE AND CENTRAL SEROUS CHORIORETINOPATHY AFTER BLUNT EYE TRAUMA.
Tekin, Kemal; Citirik, Mehmet; Atalay, Muhammed; Teke, Mehmet Yasin
2018-01-01
To report concomitant macular hole and central serous chorioretinopathy after blunt trauma. Case presentation. A 31-year-old man presented with a complaint of a reduction in visual acuity and blurred vision in the right eye after blunt eye trauma. The patient did not have a history of any systemic disorders and drug administration. On ocular examination, best corrected visual acuity was 2/20 in the right eye and 20/20 in the left eye. His intraocular pressures were 14 mmHg right eye and 13 mmHg left eye by applanation tonometry. Dilated fundus examination of the right eye showed macular hole and serous macular detachment, whereas the left eye was completely normal. Optical coherence tomography confirmed the full-thickness macular hole and subretinal fluid in the right eye, and ink-blot leakage pattern was determined in fundus fluorescein angiography. The patient was followed up without systemic therapy. Three months later, the vision was 10/20 in the right eye with completely closed macular hole and complete resolution of subretinal fluid. This is the first case which describes concomitant macular hole and central serous chorioretinopathy after blunt eye trauma. This presentation demonstrates that macular hole and central serous chorioretinopathy can be developed after blunt trauma. Both pathology may result with spontaneous closure of macular hole and spontaneous resolution of subretinal fluid within 3 months.
Deficits in eye gaze during negative social interactions in patients with schizophrenia.
Choi, Soo-Hee; Ku, Jeonghun; Han, Kiwan; Kim, Eosu; Kim, Sun I; Park, Junyoung; Kim, Jae-Jin
2010-11-01
Impaired social functioning has been reported in patients with schizophrenia. This study aimed to examine characteristics of interpersonal behaviors in patients with schizophrenia during various social interactions using the virtual reality system. Twenty-six patients and 26 controls engaged in the virtual conversation tasks, including 3 positive and 3 negative emotion-laden conversations. Eye gaze and other behavioral parameters were recorded during the listening and answering phases. The amount of eye gaze was assessed as smaller in the patients than in the controls. A significant interaction effect of group status and emotional type was found for the listening phase. The amount of eye gaze in the patients inversely correlated with self-rated scores of assertiveness for the listening phase. These results suggest that the patients displayed inadequate levels of augmentations in eye gaze during negative emotional situations. These deficits should be considered in the treatment and social skills training for patients with schizophrenia.
76 FR 18824 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-05
... vision in his left eye due to a traumatic injury that occurred in 1978. The visual acuity in his right..., has had complete loss of vision in his right eye due to a traumatic injury that occurred in 1999. The... speed limit by 10 mph. James O. Cook Mr. Cook, 62, has a central scar in his left eye due to a traumatic...
The Sony PlayStation II EyeToy: low-cost virtual reality for use in rehabilitation.
Rand, Debbie; Kizony, Rachel; Weiss, Patrice Tamar L
2008-12-01
The objective of this study was to investigate the potential of using a low-cost video-capture virtual reality (VR) platform, the Sony PlayStation II EyeToy, for the rehabilitation of older adults with disabilities. This article presents three studies that were carried out to provide information about the EyeToy's potential for use in rehabilitation. The first study included the testing of healthy young adults (N = 34) and compared their experiences using the EyeToy with those using GestureTek's IREX VR system in terms of a sense of presence, level of enjoyment, control, success, and perceived exertion. The second study aimed to characterize the VR experience of healthy older adults (N = 10) and to determine the suitability and usability of the EyeToy for this population and the third study aimed to determine the feasibility of the EyeToy for use by individuals (N = 12) with stroke at different stages. The implications of these three studies for applying the system to rehabilitation are discussed.
Asymmetric Corneal Flattening Effect After Small Incision Cataract Surgery.
Alpins, Noel; Ong, James K Y; Stamatelatos, George
2016-08-01
To determine whether the flattening effect of corneal incisions differs between the right and left eye. A retrospective study of preoperative and postoperative corneal astigmatism was performed for patients who had bilateral cataract surgery by a right-handed surgeon. The change in corneal astigmatism was attributed to the 2.2-mm phacoemulsification incision, and the incisional flattening effect was calculated. The incisions were grouped by position on the eye and whether they were performed on the preoperative steep corneal meridian. A total of 1,298 eyes of 649 patients were evaluated. The flattening effect of temporal 2.2-mm incisions performed on the preoperative corneal steep meridian was different for right eyes (0.53 diopters [D]) and left eyes (0.34 D) (P = .017). The flattening effect of superior 2.2-mm incisions performed on the preoperative corneal steep meridian was equivalent in the two eyes. The flattening effect of a corneal incision may depend on whether it has been performed on the right or the left eye. [J Refract Surg. 2016;32(9):598-603.]. Copyright 2016, SLACK Incorporated.
Spadea, Leopoldo; Maraone, Giorgia; Cagini, Carlo
2017-02-01
Posterior keratoconus is a rare corneal anomaly which is part of the ectatic corneal disorders. We report a clinical presentation of a unilateral posterior keratoconus in a 42-year-old man. At the time of presentation, corrected distance visual acuity (CDVA) was 20/20 with a correction of +2.50 +2.50 × 90° in the right eye and 20/40 with +1 +3.00 × 105° in the left eye. Slit lamp microscopy showed in the left eye an evidence of corneal thinning with a mild anterior protrusion and a remarkable posterior excavation. The intraocular pressure was 19 mmHg in right eye and 16 mmHg in left eye. Ultrasound pachymetry showed a minimum corneal thickness of 556 μ in right eye and 289 μ in left eye. The anterior segment optical coherence tomography (AS-OCT) revealed central corneal thinning and showed a reduced epithelial thickness. Videokeratography showed an increase of the corneal curvature in a defined area with central steepening in the area of the posterior corneal depression with gradual paracentral flattening. The description of this case underlines the importance of this instruments such us AS-OCT and corneal topography in diagnosis of posterior keratoconus. It can also be observed that in the contralateral eye there are no signs of ectasia as in the rare condition of unilateral keratoconus.
Vira, Divya; Fernandes, Merle; Mittal, Ruchi
2016-07-01
Xeroderma pigmentosum (XP) mainly affects the ocular surface; however, endothelial damage may also occur. We would like to report changes in the endothelial-Descemet layer and review the literature on similar findings in patients with XP, including the role of Descemet stripping automated endothelial keratoplasty (DSAEK) in the management of a 21-year-old man who presented with nonresolving corneal edema in the right eye after excision biopsy for conjunctival intraepithelial neoplasia. His best-corrected visual acuity (BCVA) was 20/200 in the right eye and 20/20 in the left eye. On general examination, there was patchy hyperpigmentation of the exposed areas of skin suggestive of XP. On examination of the right eye, there was stromal edema involving the exposed half of cornea. The left eye appeared normal. Pachymetry readings were 860 and 600 μm in the right and left eye, respectively. Descemet stripping automated endothelial keratoplasty was performed for endothelial dysfunction and the stripped endothelium, and Descemet membrane (DM) was sent for histopathologic evaluation. Postoperatively, the donor lenticule was well apposed and the overlying stromal edema resolved. The patient achieved a BCVA of 20/30 in the right eye without progression of corneal scarring at 1-year follow-up. In the meanwhile, however, the left eye developed corneal edema. Histopathology revealed gross attenuation of endothelial cells with uniform thickness of the DM. Corneal endothelial dysfunction in XP is amenable to treatment with DSAEK.
... One Choose A Body Area: Eyes Step Two Select A Symptom: Itchy eyes Step Three Possible Issues: ... conjunctivitis Mold allergy Pet allergy Nose Step Two Select A Symptom: Nasal congestion Step Three Possible Issues: ...
Schlesener, Brittany N; Scott, Erin M; Vallone, Lucien V
2017-11-07
A 1-year-old, female spayed, domestic shorthair cat presented for blepharospasm of the right eye. Slit-lamp biomicroscopic examination showed focal corneal ulceration and presumptive keratomalacia of the right eye. Examination of the left eye was normal apart from a focal endothelial opacity. Within the first 24 h of medical management, the right eye developed marked corneal edema and globular anterior protrusion of the corneal surface consistent with feline acute corneal hydrops (FACH). Surgical management consisted of a bridge conjunctival graft, nictitating membrane flap, and temporary tarsorrhaphy. Resolution of corneal edema and pain occurred in the right eye within 24 days. Spectral domain optical coherence tomography (SD-OCT) of the anterior segment was performed in both eyes. Conjunctival tissue from the bridge graft precluded examination of deeper corneal structures in the right eye. The left eye displayed a focal separation of the corneal endothelium and Descemet's membrane from the overlying stroma. These SD-OCT findings are similar to the analogous syndrome found in humans and represent a potential etiology for FACH of the right eye in the case presented here. Unfortunately, the cat was lost to follow-up and the progression of this lesion to FACH in the left eye could not be determined. © 2017 American College of Veterinary Ophthalmologists.
Familial exudative vitreoretinopathy mimicking persistent hyperplastic primary vitreous.
Chang-Godinich, A; Paysse, E A; Coats, D K; Holz, E R
1999-04-01
To report an unusual case of familial exudative vitreoretinopathy in an infant. Case report. A 6-day-old girl had unilateral microphthalmia in the right eye, with a retrolental plaque initially diagnosed as persistent hyperplastic primary vitreous. Three months later, peripheral retinal vascular changes and a fibrovascular ridge were noted in the left eye, suggesting familial exudative vitreoretinopathy as the cause in both eyes. The microphthalmic right eye was unsalvageable. The left eye developed an exudative retinal detachment despite photocoagulation of the peripheral avascular retina. Additional cryotherapy resulted in resolution of the detachment and regression of the vascular changes. With highly asymmetric involvement, neonatal familial exudative vitreoretinopathy can mimic persistent hyperplastic primary vitreous. Fellow eye involvement can progress rapidly.
Anisocoria Secondary to Anticholinergic Mydriasis from Homeopathic Pink Eye Relief Drops.
Chen, Lin; Yeung, Joseph C; Anderson, Dennis R
2017-12-01
A woman, aged 70 years, developed anisocoria after applying homeopathic eye drops (Similasan Pink Eye Relief) to her left eye. Her pupil was dilated for two weeks and did not respond to light or near stimuli for one week. Both 0.1% and 1% pilocarpine failed to constrict her left pupil, and magnetic resonance imaging of her brain did not reveal any abnormality. The eye drops she had used contain belladonna extracts which have a natural atropine component. This case demonstrates the importance, when evaluating a patient presenting with anisocoria, of knowing the chemical ingredients of the homeopathic eye drops, which often are not listed. © 2017 Marshfield Clinic.
Chaumillon, Romain; Blouin, Jean; Guillaume, Alain
2018-01-01
The interhemispheric transfer of information is a fundamental process in the human brain. When a visual stimulus appears eccentrically in one visual-hemifield, it will first activate the contralateral hemisphere but also the ipsilateral one with a slight delay due to the interhemispheric transfer. This interhemispheric transfer of visual information is believed to be faster from the right to the left hemisphere in right-handers. Such an asymmetry is considered as a relevant fact in the context of the lateralization of the human brain. We show here using current source density (CSD) analyses of visually evoked potential (VEP) that, in right-handers and, to a lesser extent in left-handers, this asymmetry is in fact dependent on the sighting eye dominance, the tendency we have to prefer one eye for monocular tasks. Indeed, in right-handers, a faster interhemispheric transfer of visual information from the right to left hemisphere was observed only in participants with a right dominant eye (DE). Right-handers with a left DE showed the opposite pattern, with a faster transfer from the left to the right hemisphere. In left-handers, albeit a smaller number of participants has been tested and hence confirmation is required, only those with a right DE showed an asymmetrical interhemispheric transfer with a faster transfer from the right to the left hemisphere. As a whole these results demonstrate that eye dominance is a fundamental determinant of asymmetries in interhemispheric transfer of visual information and suggest that it is an important factor of brain lateralization. PMID:29515351
Chaumillon, Romain; Blouin, Jean; Guillaume, Alain
2018-01-01
The interhemispheric transfer of information is a fundamental process in the human brain. When a visual stimulus appears eccentrically in one visual-hemifield, it will first activate the contralateral hemisphere but also the ipsilateral one with a slight delay due to the interhemispheric transfer. This interhemispheric transfer of visual information is believed to be faster from the right to the left hemisphere in right-handers. Such an asymmetry is considered as a relevant fact in the context of the lateralization of the human brain. We show here using current source density (CSD) analyses of visually evoked potential (VEP) that, in right-handers and, to a lesser extent in left-handers, this asymmetry is in fact dependent on the sighting eye dominance, the tendency we have to prefer one eye for monocular tasks. Indeed, in right-handers, a faster interhemispheric transfer of visual information from the right to left hemisphere was observed only in participants with a right dominant eye (DE). Right-handers with a left DE showed the opposite pattern, with a faster transfer from the left to the right hemisphere. In left-handers, albeit a smaller number of participants has been tested and hence confirmation is required, only those with a right DE showed an asymmetrical interhemispheric transfer with a faster transfer from the right to the left hemisphere. As a whole these results demonstrate that eye dominance is a fundamental determinant of asymmetries in interhemispheric transfer of visual information and suggest that it is an important factor of brain lateralization.
Meena, Yogesh Kumar; Cecotti, Hubert; Wong-Lin, Kongfatt; Dutta, Ashish; Prasad, Girijesh
2018-04-01
Virtual keyboard applications and alternative communication devices provide new means of communication to assist disabled people. To date, virtual keyboard optimization schemes based on script-specific information, along with multimodal input access facility, are limited. In this paper, we propose a novel method for optimizing the position of the displayed items for gaze-controlled tree-based menu selection systems by considering a combination of letter frequency and command selection time. The optimized graphical user interface layout has been designed for a Hindi language virtual keyboard based on a menu wherein 10 commands provide access to type 88 different characters, along with additional text editing commands. The system can be controlled in two different modes: eye-tracking alone and eye-tracking with an access soft-switch. Five different keyboard layouts have been presented and evaluated with ten healthy participants. Furthermore, the two best performing keyboard layouts have been evaluated with eye-tracking alone on ten stroke patients. The overall performance analysis demonstrated significantly superior typing performance, high usability (87% SUS score), and low workload (NASA TLX with 17 scores) for the letter frequency and time-based organization with script specific arrangement design. This paper represents the first optimized gaze-controlled Hindi virtual keyboard, which can be extended to other languages.
Feng, Zhi-hong; Dong, Yan; Bai, Shi-zhu; Wu, Guo-feng; Bi, Yun-peng; Wang, Bo; Zhao, Yi-min
2010-01-01
The aim of this article was to demonstrate a novel approach to designing facial prostheses using the transplantation concept and computer-assisted technology for extensive, large, maxillofacial defects that cross the facial midline. The three-dimensional (3D) facial surface images of a patient and his relative were reconstructed using data obtained through optical scanning. Based on these images, the corresponding portion of the relative's face was transplanted to the patient's where the defect was located, which could not be rehabilitated using mirror projection, to design the virtual facial prosthesis without the eye. A 3D model of an artificial eye that mimicked the patient's remaining one was developed, transplanted, and fit onto the virtual prosthesis. A personalized retention structure for the artificial eye was designed on the virtual facial prosthesis. The wax prosthesis was manufactured through rapid prototyping, and the definitive silicone prosthesis was completed. The size, shape, and cosmetic appearance of the prosthesis were satisfactory and matched the defect area well. The patient's facial appearance was recovered perfectly with the prosthesis, as determined through clinical evaluation. The optical 3D imaging and computer-aided design/computer-assisted manufacturing system used in this study can design and fabricate facial prostheses more precisely than conventional manual sculpturing techniques. The discomfort generally associated with such conventional methods was decreased greatly. The virtual transplantation used to design the facial prosthesis for the maxillofacial defect, which crossed the facial midline, and the development of the retention structure for the eye were both feasible.
Lazzari, Roberta Delasta; Politti, Fabiano; Santos, Cibele Alimedia; Dumont, Arislander Jonathan Lopes; Rezende, Fernanda Lobo; Grecco, Luanda André Collange; Braun Ferreira, Luiz Alfredo; Oliveira, Claudia Santos
2015-01-01
[Purpose] The aim of the present study was to investigate the effects of a single session of transcranial direct current stimulation combined with virtual reality training on the balance of children with cerebral palsy. [Subjetcs and Methods] Children with cerebral palsy between four and 12 years of age were randomly allocated to two groups: an experimental group which performed a single session of mobility training with virtual reality combined with active transcranial direct current stimulation; and a control group which performed a single session of mobility training with virtual reality combined with placebo transcranial direct current stimulation. The children were evaluated before and after the training protocols. Static balance (sway area, displacement, velocity and frequency of oscillations of the center of pressure on the anteroposterior and mediolateral axes) was evaluated using a force plate under four conditions (30-second measurements for each condition): feet on the force plate with the eyes open, and with the eyes closed; feet on a foam mat with the eyes open, and with the eyes closed. [Results] An increase in sway velocity was the only significant difference found. [Conclusion] A single session of anodal transcranial direct current stimulation combined with mobility training elicited to lead to an increase in the body sway velocity of children with cerebral palsy. PMID:25931726
Unilateral external and internal ophthalmoplegia caused by intracranial meningioma in a dog.
Larocca, R.D.
2000-01-01
Unilateral internal and external ophthalmoplegia caused by an intracranial meningioma occurred in a 15-year-old Belgian Sheepdog. The dog initially presented with ventro-lateral strabismus of the left eye, and ptosis of the left upper eyelid. Anisocoria was present with the left pupil fixed and dilated. Both eyes were visual. Neuro-ophthalmic evaluation revealed a lesion located in the left oculomotor nerve. Pharmacological testing with dilute pilocarpine (0.1% in artificial tears) revealed evidence of parasympathetic denervation of the left eye. Further evaluation via magnetic resonance imaging (MRI) revealed a well-defined mass to the left of midline and lateral to the sella turcica. An attempt was made to excise/debulk the mass due to worsening conditions and the dog died the following day. Necropsy revealed a mass of randomly arranged bundles and streams of spindle cells. Immunohistochemistry demonstrated a strong avidity for vimentin and a negative response for S-100 protein. These findings suggest a diagnosis of meningioma.
Netto, Marcelo V; Chalita, Maria Regina; Krueger, Ronald R
2007-01-01
To report photorefractive keratectomy (PRK) treated with mitomycin C (MMC) for previous corneal haze in one eye and PRK with MMC to prevent corneal haze formation in the fellow eye. A 40-year-old woman underwent PRK with MMC to treat previous corneal haze (secondary to previous PRK without MMC) for residual refractive error of +0.50 +0.25 x 165 in the left eye and PRK with MMC to prevent corneal haze in the right eye. Postoperative slit-lamp examination revealed no haze in the right eye, but continued mild haze in the left eye. Treatment with PRK and MMC for previous corneal haze is not as effective as primary PRK with MMC in preventing postoperative corneal haze formation.
Sun, I-Ting; Lee, Tsung-Han; Chen, Chih-Hsin
2017-01-01
We report a case of rapid cataract progression after Nd:YAG vitreolysis for vitreous floaters. A 55-year-old man presented with acute onset of blurred vision following Nd:YAG vitreolysis for symptomatic floaters in the left eye. His initial best corrected visual acuity (BCVA) was 20/1,000 in the left eye. Ocular examinations showed frost-like opacities of the lens and a suspected break of the posterior capsule in the left eye. There were no detectable retinal lesions. Cataract surgery was then arranged. Posterior capsular rupture and vitreous loss occurred during surgery, which required a subsequent pars plana vitrectomy. After the surgery, BCVA in the left eye gradually improved to 20/20 and was maintained during a 1-year follow-up period. Crystalline lens injuries and rapid cataract progression may occur following Nd:YAG vitreolysis. While dealing with this type of complicated cataract, clinicians should be aware of the possibility of posterior lens capsule rupture during surgery and the need for combined vitrectomy.
Stereo View of Martian Rock Target 'Funzie'
2018-02-08
The surface of the Martian rock target in this stereo image includes small hollows with a "swallowtail" shape characteristic of some gypsum crystals, most evident in the lower left quadrant. These hollows may have resulted from the original crystallizing mineral subsequently dissolving away. The view appears three-dimensional when seen through blue-red glasses with the red lens on the left. The scene spans about 2.5 inches (6.5 centimeters). This rock target, called "Funzie," is near the southern, uphill edge of "Vera Rubin Ridge" on lower Mount Sharp. The stereo view combines two images taken from slightly different angles by the Mars Hand Lens Imager (MAHLI) camera on NASA's Curiosity Mars rover, with the camera about 4 inches (10 centimeters) above the target. Fig. 1 and Fig. 2 are the separate "right-eye" and "left-eye" images, taken on Jan. 11, 2018, during the 1,932nd Martian day, or sol, of the rover's work on Mars. Right-eye and left-eye images are available at https://photojournal.jpl.nasa.gov/catalog/PIA22212
The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation
Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt
2010-01-01
Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.
Manually locating physical and virtual reality objects.
Chen, Karen B; Kimmel, Ryan A; Bartholomew, Aaron; Ponto, Kevin; Gleicher, Michael L; Radwin, Robert G
2014-09-01
In this study, we compared how users locate physical and equivalent three-dimensional images of virtual objects in a cave automatic virtual environment (CAVE) using the hand to examine how human performance (accuracy, time, and approach) is affected by object size, location, and distance. Virtual reality (VR) offers the promise to flexibly simulate arbitrary environments for studying human performance. Previously, VR researchers primarily considered differences between virtual and physical distance estimation rather than reaching for close-up objects. Fourteen participants completed manual targeting tasks that involved reaching for corners on equivalent physical and virtual boxes of three different sizes. Predicted errors were calculated from a geometric model based on user interpupillary distance, eye location, distance from the eyes to the projector screen, and object. Users were 1.64 times less accurate (p < .001) and spent 1.49 times more time (p = .01) targeting virtual versus physical box corners using the hands. Predicted virtual targeting errors were on average 1.53 times (p < .05) greater than the observed errors for farther virtual targets but not significantly different for close-up virtual targets. Target size, location, and distance, in addition to binocular disparity, affected virtual object targeting inaccuracy. Observed virtual box inaccuracy was less than predicted for farther locations, suggesting possible influence of cues other than binocular vision. Human physical interaction with objects in VR for simulation, training, and prototyping involving reaching and manually handling virtual objects in a CAVE are more accurate than predicted when locating farther objects.
Singh, Tarkeshwar; Perry, Christopher M; Herter, Troy M
2016-01-26
Robotic and virtual-reality systems offer tremendous potential for improving assessment and rehabilitation of neurological disorders affecting the upper extremity. A key feature of these systems is that visual stimuli are often presented within the same workspace as the hands (i.e., peripersonal space). Integrating video-based remote eye tracking with robotic and virtual-reality systems can provide an additional tool for investigating how cognitive processes influence visuomotor learning and rehabilitation of the upper extremity. However, remote eye tracking systems typically compute ocular kinematics by assuming eye movements are made in a plane with constant depth (e.g. frontal plane). When visual stimuli are presented at variable depths (e.g. transverse plane), eye movements have a vergence component that may influence reliable detection of gaze events (fixations, smooth pursuits and saccades). To our knowledge, there are no available methods to classify gaze events in the transverse plane for monocular remote eye tracking systems. Here we present a geometrical method to compute ocular kinematics from a monocular remote eye tracking system when visual stimuli are presented in the transverse plane. We then use the obtained kinematics to compute velocity-based thresholds that allow us to accurately identify onsets and offsets of fixations, saccades and smooth pursuits. Finally, we validate our algorithm by comparing the gaze events computed by the algorithm with those obtained from the eye-tracking software and manual digitization. Within the transverse plane, our algorithm reliably differentiates saccades from fixations (static visual stimuli) and smooth pursuits from saccades and fixations when visual stimuli are dynamic. The proposed methods provide advancements for examining eye movements in robotic and virtual-reality systems. Our methods can also be used with other video-based or tablet-based systems in which eye movements are performed in a peripersonal plane with variable depth.
A Well-Traveled 'Eagle Crater' (left-eye)
NASA Technical Reports Server (NTRS)
2004-01-01
This is the left-eye version of the Mars Exploration Rover Opportunity's view on its 56th sol on Mars, before it left its landing-site crater. To the right, the rover tracks are visible at the original spot where the rover attempted unsuccessfully to exit the crater. After a one-sol delay, Opportunity took another route to the plains of Meridiani Planum. This image was taken by the rover's navigation camera.
Optic nerve involvement in a borderline lepromatous leprosy patient on multidrug therapy.
Prabha, Neel; Mahajan, Vikram K; Sharma, Surinder K; Sharma, Vikas; Chauhan, Pushpinder S; Mehta, Karaninder S; Abhinav, C; Khatri, Gaytri; Chander, Bal; Tuli, Rajiv
2013-12-01
Amidst the plethora of ocular complications of leprosy, involvement of the posterior segment or optic nerve is extremely rare. The mechanism of optic neuritis in leprosy is poorly understood. A 47 year-old man presented with a single lesion suggestive of mid-borderline (BB) leprosy over left periorbital region; the histology showed borderline lepromatous (BL) leprosy with a BI of 3+. After initial improvement with WHO MDT-MB and prednisolone (40 mg/d) he developed sudden and painless diminished vision in the left eye, about 3 weeks later. His visual acuity was 6/9 in the left and 6/6 in the right eye, and there was left optic disc edema, hyperemia and blurred disc margins. Treatment with prednisolone (60 mg/d) along with WHO MDT-MB continued. A month later he returned with painless diminished vision in the other eye as well. Visual acuity was 6/6 in the right and 6/12 in the left eye, and there was right optic disc edema and left optic disc atrophy. CT of the head and MRI of the brain were normal. Inflammatory edema of the orbital connective tissue or other surrounding structures, or direct infiltration of vasa nervosa with resultant vascular occlusion leading to optic nerve ischemia, seems the most plausible explanation of optic nerve involvement in this case.
Eye-hand preference in schizophrenia: sex differences and significance for hand function.
Liu, Yi-Chia; Yang, Yen Kuang; Lee, I Hui; Lin, Keh-Chung; Jeffries, Keith J; Lee, Li-Ching
2004-06-01
Hand preference and eye dominance were investigated in 73 (30 women, 43 men) schizophrenic patients and 71 (30 women, 41 men) healthy controls. There were significantly more schizophrenic patients and normal controls who were significantly right-hand dominant. However, schizophrenic patients showed a significant excess of left-eye dominance relative to controls (65.8% vs 29.6%; Odds Ratio= 4.75, p< .001). In addition, female schizophrenic patients showed a higher rate of nonright (either left or inconsistent) eye dominance (80%) than male schizophrenic patients (55.8%) and controls (33.3%). Analysis of hand performance on the Purdue Pegboard Test indicated that schizophrenic patients who showed crossed eye-hand dominance scored higher than did patients without crossed eye-hand dominance.
Moschos, Marilita M; Nitoda, Eirini; Chatziralli, Irini P; Gatzioufas, Zisis; Koutsandrea, Chryssanthi; Kitsos, George
2015-01-01
Objective This study was conducted to evaluate the macular status of patients treated with hydroxychloroquine before and after cessation of treatment. Methods Forty-two patients with systemic lupus erythematosus underwent ocular examination based on visual acuity evaluation, optical coherence tomography retinal thickness measurements, and multifocal electroretinography (mfERG) records at first visit. The tests were repeated 6 months after treatment withdrawal and compared to the findings at their first visit. Results Mean visual acuity (measured in log minimum angle of resolution) of both eyes was statistically increased after hydroxychloroquine discontinuation (difference in means: 0.06 [P<0.0001] and 0.01 [P=0.003] for the right and left eyes, respectively). Retinal response amplitudes of central and peripheral areas were significantly improved for both eyes. The following values were observed for central responses: the difference in means was −19.9 (P<0.0001) and −13.6 (P<0.0001) for the right eye and the left eye, respectively; for peripheral responses, difference in means was −10.3 (P<0.0001) and −9.5 (P<0.0001) for right eye and left eye, respectively, after the 6-month examination. There were no statistically significant differences in the retinal thickness of patients after cessation of treatment. The visual acuity of the patients was correlated to central and peripheral mfERG responses (r=−0.53 [P<0.0001] and r=−0.53 [P<0.0001], for the right eye and the left eye, respectively). Conclusion The visual acuity of patients receiving hydroxychloroquine improves along with the amplitudes of the mfERG responses 6 months after discontinuation of the drug, but no difference in retinal thickness is identified. PMID:26089648
Moschos, Marilita M; Nitoda, Eirini; Chatziralli, Irini P; Gatzioufas, Zisis; Koutsandrea, Chryssanthi; Kitsos, George
2015-01-01
This study was conducted to evaluate the macular status of patients treated with hydroxychloroquine before and after cessation of treatment. Forty-two patients with systemic lupus erythematosus underwent ocular examination based on visual acuity evaluation, optical coherence tomography retinal thickness measurements, and multifocal electroretinography (mfERG) records at first visit. The tests were repeated 6 months after treatment withdrawal and compared to the findings at their first visit. Mean visual acuity (measured in log minimum angle of resolution) of both eyes was statistically increased after hydroxychloroquine discontinuation (difference in means: 0.06 [P<0.0001] and 0.01 [P=0.003] for the right and left eyes, respectively). Retinal response amplitudes of central and peripheral areas were significantly improved for both eyes. The following values were observed for central responses: the difference in means was -19.9 (P<0.0001) and -13.6 (P<0.0001) for the right eye and the left eye, respectively; for peripheral responses, difference in means was -10.3 (P<0.0001) and -9.5 (P<0.0001) for right eye and left eye, respectively, after the 6-month examination. There were no statistically significant differences in the retinal thickness of patients after cessation of treatment. The visual acuity of the patients was correlated to central and peripheral mfERG responses (r=-0.53 [P<0.0001] and r=-0.53 [P<0.0001], for the right eye and the left eye, respectively). The visual acuity of patients receiving hydroxychloroquine improves along with the amplitudes of the mfERG responses 6 months after discontinuation of the drug, but no difference in retinal thickness is identified.
Enhanced iris recognition method based on multi-unit iris images
NASA Astrophysics Data System (ADS)
Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung
2013-04-01
For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the averaged equal error rate of iris recognition using the proposed method was 4.3006%, which is lower than that of other methods.
Vergilino-Perez, Dorine; Fayel, Alexandra; Lemoine, Christelle; Senot, Patrice; Vergne, Judith; Doré-Mazars, Karine
2012-06-05
Hemispheric specialization in saccadic control is still under debate. Here we examine the latency, gain, and peak velocity of reactive and voluntary leftward and rightward saccades to assess the respective roles of eye and hand dominance. Participants with contrasting hand and eye dominance were asked to make saccades toward a target displayed at 5°, 10°, or 15° left or right of the central fixation point. In separate sessions, reactive and voluntary saccades were elicited by Gap-200, Gap-0, Overlap-600, and Antisaccade procedures. Left-right asymmetries were not found in saccade latencies but appeared in saccade gain and peak velocity. Regardless of the dominant hand, saccades directed to the ipsilateral side relative to the dominant eye had larger amplitudes and faster peak velocities. Left-right asymmetries can be explained by naso-temporal differences for some subjects and by eye dominance for others. Further investigations are needed to examine saccadic parameters more systematically in relation to eye dominance. Indeed, any method that allows one to determine ocular dominance from objective measures based on saccade parameters should greatly benefit clinical applications, such as monovision surgery.
Neurophysiological intraoperative monitoring during an optic nerve schwannoma removal.
San-Juan, Daniel; Escanio Cortés, Manuel; Tena-Suck, Martha; Orozco Garduño, Adolfo Josué; López Pizano, Jesús Alejandro; Villanueva Domínguez, Jonathan; Fernández Gónzalez-Aragón, Maricarmen; Gómez-Amador, Juan Luis
2017-10-01
This paper reports the case of a patient with optic nerve schwannoma and the first use of neurophysiological intraoperative monitoring of visual evoked potentials during the removal of such tumor with no postoperative visual damage. Schwannomas are benign neoplasms of the peripheral nervous system arising from the neural crest-derived Schwann cells, these tumors are rarely located in the optic nerve and the treatment consists on surgical removal leading to high risk of damage to the visual pathway. Case report of a thirty-year-old woman with an optic nerve schwannoma. The patient underwent surgery for tumor removal on the left optic nerve through a left orbitozygomatic approach with intraoperative monitoring of left II and III cranial nerves. We used Nicolet Endeavour CR IOM (Carefusion, Middleton WI, USA) to performed visual evoked potentials stimulating binocularly with LED flash goggles with the patient´s eyes closed and direct epidural optic nerve stimulation delivering rostral to the tumor a rectangular current pulse. At follow up examinations 7 months later, the left eye visual acuity was 20/60; Ishihara score was 8/8 in both eyes; the right eye photomotor reflex was normal and left eye was mydriatic and arreflectic; optokinetic reflex and ocular conjugate movements were normal. In this case, the epidural direct electrical stimulation of optic nerve provided stable waveforms during optic nerve schwannoma resection without visual loss.
Right hemisphere advantage for social recognition in the chick.
Vallortigara, G
1992-09-01
Recognition of familiar and unfamiliar conspecifics was studied in pair-reared chicks tested binocularly or with only one eye in use. Chicks were tested on day 3 in pairs composed of either cagemates or strangers. Social discrimination, as measured by the ratio "number of pecks at the strangers/total number of pecks" was impaired in right-eyed chicks with respect to left-eyed and binocular chicks. Male chicks showed higher levels of social pecking than females, and chicks that used both eyes showed higher pecking than monocular chicks. There were no significant differences in the total number of pecks (i.e. pecks at companions plus pecks at strangers) between right- and left-eyed chicks: the impairment in social discrimination of right-eyed chicks seemed to be due partly to a reduction in pecking at strangers and partly to an increase in pecking at companions. It is suggested that neural structures fed by the left eye (mainly located at the right hemisphere) are better at processing and/or storing of visual information which allows recognition of individual conspecifics. This may be part of a wider tendency to respond to small changes in any of a variety of intrinsic stimulus properties.
3D Display Using Conjugated Multiband Bandpass Filters
NASA Technical Reports Server (NTRS)
Bae, Youngsam; White, Victor E.; Shcheglov, Kirill
2012-01-01
Stereoscopic display techniques are based on the principle of displaying two views, with a slightly different perspective, in such a way that the left eye views only by the left eye, and the right eye views only by the right eye. However, one of the major challenges in optical devices is crosstalk between the two channels. Crosstalk is due to the optical devices not completely blocking the wrong-side image, so the left eye sees a little bit of the right image and the right eye sees a little bit of the left image. This results in eyestrain and headaches. A pair of interference filters worn as an optical device can solve the problem. The device consists of a pair of multiband bandpass filters that are conjugated. The term "conjugated" describes the passband regions of one filter not overlapping with those of the other, but the regions are interdigitated. Along with the glasses, a 3D display produces colors composed of primary colors (basis for producing colors) having the spectral bands the same as the passbands of the filters. More specifically, the primary colors producing one viewpoint will be made up of the passbands of one filter, and those of the other viewpoint will be made up of the passbands of the conjugated filter. Thus, the primary colors of one filter would be seen by the eye that has the matching multiband filter. The inherent characteristic of the interference filter will allow little or no transmission of the wrong side of the stereoscopic images.
Misslisch, H; Hess, B J M
2002-11-01
This study examined two kinematical features of the rotational vestibulo-ocular reflex (VOR) of the monkey in near vision. First, is there an effect of eye position on the axes of eye rotation during yaw, pitch and roll head rotations when the eyes are converged to fixate near targets? Second, do the three-dimensional positions of the left and right eye during yaw and roll head rotations obey the binocular extension of Listing's law (L2), showing eye position planes that rotate temporally by a quarter as far as the angle of horizontal vergence? Animals fixated near visual targets requiring 17 or 8.5 degrees vergence and placed at straight ahead, 20 degrees up, down, left, or right during yaw, pitch, and roll head rotations at 1 Hz. The 17 degrees vergence experiments were performed both with and without a structured visual background, the 8.5 degrees vergence experiments with a visual background only. A 40 degrees horizontal change in eye position never influenced the axis of eye rotation produced by the VOR during pitch head rotation. Eye position did not affect the VOR eye rotation axes, which stayed aligned with the yaw and roll head rotation axes, when torsional gain was high. If torsional gain was low, eccentric eye positions produced yaw and roll VOR eye rotation axes that tilted somewhat in the directions predicted by Listing's law, i.e., with or opposite to gaze during yaw or roll. These findings were seen in both visual conditions and in both vergence experiments. During yaw and roll head rotations with a 40 degrees vertical change in gaze, torsional eye position followed on average the prediction of L2: the left eye showed counterclockwise (ex-) torsion in down gaze and clockwise (in-) torsion in up gaze and vice versa for the right eye. In other words, the left and right eye's position plane rotated temporally by about a quarter of the horizontal vergence angle. Our results indicate that torsional gain is the central mechanism by which the brain adjusts the retinal image stabilizing function of the VOR both in far and near vision and the three dimensional eye positions during yaw and roll head rotations in near vision follow on average the predictions of L2, a kinematic pattern that is maintained by the saccadic/quick phase system.
NASA Technical Reports Server (NTRS)
2004-01-01
This is the left-eye version of the 3-D cylindrical-perspective mosaic showing the view south of the martian crater dubbed 'Bonneville.' The image was taken by the navigation camera on the Mars Exploration Rover Spirit. The rover will travel toward the Columbia Hills, seen here at the upper left. The rock dubbed 'Mazatzal' and the hole the rover drilled in to it can be seen at the lower left. The rover's position is referred to as 'Site 22, Position 32.' This image was geometrically corrected to make the horizon appear flat.
The need for virtual reality simulators in dental education: A review.
Roy, Elby; Bakr, Mahmoud M; George, Roy
2017-04-01
Virtual reality simulators are becoming an essential part of modern education. The benefits of Virtual reality in dentistry is constantly being assessed as a method or an adjunct to improve fine motor skills, hand-eye coordination in pre-clinical settings and overcome the monetary and intellectual challenges involved with such training. This article, while providing an overview of the virtual reality dental simulators, also looks at the link between virtual reality simulation and current pedagogical knowledge.
Virtual faces expressing emotions: an initial concomitant and construct validity study.
Joyal, Christian C; Jacob, Laurence; Cigna, Marie-Hélène; Guay, Jean-Pierre; Renaud, Patrice
2014-01-01
Facial expressions of emotions represent classic stimuli for the study of social cognition. Developing virtual dynamic facial expressions of emotions, however, would open-up possibilities, both for fundamental and clinical research. For instance, virtual faces allow real-time Human-Computer retroactions between physiological measures and the virtual agent. The goal of this study was to initially assess concomitants and construct validity of a newly developed set of virtual faces expressing six fundamental emotions (happiness, surprise, anger, sadness, fear, and disgust). Recognition rates, facial electromyography (zygomatic major and corrugator supercilii muscles), and regional gaze fixation latencies (eyes and mouth regions) were compared in 41 adult volunteers (20 ♂, 21 ♀) during the presentation of video clips depicting real vs. virtual adults expressing emotions. Emotions expressed by each set of stimuli were similarly recognized, both by men and women. Accordingly, both sets of stimuli elicited similar activation of facial muscles and similar ocular fixation times in eye regions from man and woman participants. Further validation studies can be performed with these virtual faces among clinical populations known to present social cognition difficulties. Brain-Computer Interface studies with feedback-feedforward interactions based on facial emotion expressions can also be conducted with these stimuli.
Virtual Reality Exploration and Planning for Precision Colorectal Surgery.
Guerriero, Ludovica; Quero, Giuseppe; Diana, Michele; Soler, Luc; Agnus, Vincent; Marescaux, Jacques; Corcione, Francesco
2018-06-01
Medical software can build a digital clone of the patient with 3-dimensional reconstruction of Digital Imaging and Communication in Medicine images. The virtual clone can be manipulated (rotations, zooms, etc), and the various organs can be selectively displayed or hidden to facilitate a virtual reality preoperative surgical exploration and planning. We present preliminary cases showing the potential interest of virtual reality in colorectal surgery for both cases of diverticular disease and colonic neoplasms. This was a single-center feasibility study. The study was conducted at a tertiary care institution. Two patients underwent a laparoscopic left hemicolectomy for diverticular disease, and 1 patient underwent a laparoscopic right hemicolectomy for cancer. The 3-dimensional virtual models were obtained from preoperative CT scans. The virtual model was used to perform preoperative exploration and planning. Intraoperatively, one of the surgeons was manipulating the virtual reality model, using the touch screen of a tablet, which was interactively displayed to the surgical team. The main outcome was evaluation of the precision of virtual reality in colorectal surgery planning and exploration. In 1 patient undergoing laparoscopic left hemicolectomy, an abnormal origin of the left colic artery beginning as an extremely short common trunk from the inferior mesenteric artery was clearly seen in the virtual reality model. This finding was missed by the radiologist on CT scan. The precise identification of this vascular variant granted a safe and adequate surgery. In the remaining cases, the virtual reality model helped to precisely estimate the vascular anatomy, providing key landmarks for a safer dissection. A larger sample size would be necessary to definitively assess the efficacy of virtual reality in colorectal surgery. Virtual reality can provide an enhanced understanding of crucial anatomical details, both preoperatively and intraoperatively, which could contribute to improve safety in colorectal surgery.
Arvind, Hemamalini; Klistorner, Alexander; Graham, Stuart L; Grigg, John R
2006-05-01
Multifocal visual evoked potentials (mfVEPs) have demonstrated good diagnostic capabilities in glaucoma and optic neuritis. This study aimed at evaluating the possibility of simultaneously recording mfVEP for both eyes with dichoptic stimulation using virtual reality goggles and also to determine the stimulus characteristics that yield maximum amplitude. ten healthy volunteers were recruited and temporally sparse pattern pulse stimuli were presented dichoptically using virtual reality goggles. Experiment 1 involved recording responses to dichoptically presented checkerboard stimuli and also confirming true topographic representation by switching off specific segments. Experiment 2 involved monocular stimulation and comparison of amplitude with Experiment 1. In Experiment 3, orthogonally oriented gratings were dichoptically presented. Experiment 4 involved dichoptic presentation of checkerboard stimuli at different levels of sparseness (5.0 times/s, 2.5 times/s, 1.66 times/s and 1.25 times/s), where stimulation of corresponding segments of two eyes were separated by 16.7, 66.7,116.7 & 166.7 ms respectively. Experiment 1 demonstrated good traces in all regions and confirmed topographic representation. However, there was suppression of amplitude of responses to dichoptic stimulation by 17.9+/-5.4% compared to monocular stimulation. Experiment 3 demonstrated similar suppression between orthogonal and checkerboard stimuli (p = 0.08). Experiment 4 demonstrated maximum amplitude and least suppression (4.8%) with stimulation at 1.25 times/s with 166.7 ms separation between eyes. It is possible to record mfVEP for both eyes during dichoptic stimulation using virtual reality goggles, which present binocular simultaneous patterns driven by independent sequences. Interocular suppression can be almost eliminated by using a temporally sparse stimulus of 1.25 times/s with a separation of 166.7 ms between stimulation of corresponding segments of the two eyes.
Posterior Segment Toxicity Following Gemcitabine and Docetaxel Chemotherapy
Valeshabad, Ali Kord; Mieler, William F.; Setlur, Vikram; Thomas, Merina; Shahidi, Mahnaz
2015-01-01
Purpose To report outer retinal disruption and uveal effusion following gemcitabine and docetaxel combination therapy. Case Report A 78-year-old woman presented with blurry vision following two cycles of gemcitabine and docetaxel combination chemotherapy for stage IV sarcoma. At presentation, visual acuity (VA) was finger counting and 20/25 in the right and left eyes, respectively. Slit lamp examination and B scan ultrasonography revealed severe uveal effusion in the right eye and choroidal folds in the left eye. Spectral domain optical coherence tomography showed disruption of photoreceptor inner segment ellipsoid band in the right eye. The patient was monitored weekly with ophthalmic examination and B scan ultrasonography, while continuing with gemcitabine monotherapy. At 8 weeks follow up, uveal effusion improved considerably and VA was 20/40 and 20/20 in the right and left eyes, respectively. Conclusions Uveal effusion and outer retinal disruption were reported following gemcitabine and docetaxel chemotherapy. Early detection and close ophthalmic monitoring may allow concurrent cancer treatment and prevention of possible chemotherapy-induced ocular side effects. PMID:25822016
Postanaesthetic tear production and ocular irritation in cats.
Peche, N; Köstlin, R; Reese, S; Pieper, K
2015-01-01
General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.
Retinitis pigmentosa inversa with unilateral high myopia with fellow eye optic disc pitting.
Sheth, Saumil; Rush, Ryan; Narayanan, Raja
2011-01-01
To report a possible rare association of bilateral retinitis pigmentosa inversa (RPI) with unilateral high myopia with fellow eye optic disc pitting. A 55-year-old man with a history of reduced vision in the right eye since childhood presented with gradually decreasing vision in the left eye. On examination, a -23.00 diopter refractive error and diffuse chorioretinal atrophy consistent with pathologic myopia was found in the right eye. An optic disc pit with posterior pole pigmentary alterations thought to be consequent to a previous neurosensory detachment was found in the left eye. Though the retinal arteriolar attenuation seen in both eyes with an inconsistent history of night blindness since childhood pointed towards the possibility of a concurrently existing rod or rod-cone dystrophy, the posterior pole pigmentary alterations characteristic of RPI were clearly masked by the above pathologies. Optical coherence tomography demonstrated prominent foveal atrophy and an optic disc pit in the left eye. Electroretinography (ERG) demonstrated moderately attenuated amplitudes with prolonged implicit times of rod and cone responses bilaterally. The patient was diagnosed with bilateral RPI and anisometropic amblyopia in the right eye. This report documents a unique constellation of findings which include bilateral RPI and unilateral high myopia with an optic disc pit in the fellow eye. An ERG confirmation of a dystrophic etiology should be sought in suspicious cases, especially when findings are masked by the concurrent presence of other pathologies.
Eliciting nicotine craving with virtual smoking cues.
Gamito, Pedro; Oliveira, Jorge; Baptista, André; Morais, Diogo; Lopes, Paulo; Rosa, Pedro; Santos, Nuno; Brito, Rodrigo
2014-08-01
Craving is a strong desire to consume that emerges in every case of substance addiction. Previous studies have shown that eliciting craving with an exposure cues protocol can be a useful option for the treatment of nicotine dependence. Thus, the main goal of this study was to develop a virtual platform in order to induce craving in smokers. Fifty-five undergraduate students were randomly assigned to two different virtual environments: high arousal contextual cues and low arousal contextual cues scenarios (17 smokers with low nicotine dependency were excluded). An eye-tracker system was used to evaluate attention toward these cues. Eye fixation on smoking-related cues differed between smokers and nonsmokers, indicating that smokers focused more often on smoking-related cues than nonsmokers. Self-reports of craving are in agreement with these results and suggest a significant increase in craving after exposure to smoking cues. In sum, these data support the use of virtual environments for eliciting craving.
John, Sheila; Premila, M; Javed, Mohd; Vikas, G; Wagholikar, Amol
2015-01-01
To inform about a very unique and first of its kind telehealth pilot study in India that has provided virtual telehealth consultation to eye care patients in low resource at remote villages. Provision of Access to eye care services in remote population is always challenging due to pragmatic reasons. Advances in Telehealth technologies have provided an opportunity to improve access to remote population. However, current Telehealth technologies are limited to face-to-face video consultation only. We inform about a pilot study that illustrates real-time imaging access to ophthalmologists. Our innovative software led technology solution allowed screening of patients with varying ocular conditions. Eye camps were conducted in 2 districts in South India over a 12-month period in 2014. Total of 196 eye camps were conducted. Total of 19,634 patients attended the eye camps. Innovative software was used to conduct consultation with the ophthalmologist located in the city hospital. The software enabled virtual visit and allowed instant sharing of fundus camera images for assessment and diagnosis. About 71% of the patients were found to have Refractive Error problems, 15% of them were found to have cataract, 7% of the patients were diagnosed to have Retina problems and 7% of the patients were found to have other ocular diseases. The patients requiring cataract surgery were immediately transferred to city hospital for treatment. Software led assessment of fundus camera images assisted in identifying retinal eye diseases. Our real-time virtual visit software assisted in specialist care provision and illustrated a novel tele health solution for low resource population.
Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.
Ravikumar, Ayeswarya; Benoit, Julia S; Morrison, Kelsie B; Marsack, Jason D; Anderson, Heather A
2018-03-01
Individuals with Down syndrome may experience greater difficulty reliably performing visual acuity (VA) tests because of intellectual disability and limitations in visual quality. This study evaluated the repeatability of acuity (Bailey-Lovie [BL] and HOTV) in subjects with and without Down syndrome. High-contrast VA was measured in both eyes of 30 subjects with Down syndrome (mean, 30 years; range, 18 to 50 years) and 24 control subjects without Down syndrome (mean, 29 years; range, 18 to 50 years). In the Down syndrome group, 23 subjects performed BL, and 7 subjects performed HOTV. All control subjects performed both BL and HOTV, but for HOTV analysis, only seven age-matched control subjects were included. For each eye, subjects performed VA three times on different charts (computer controlled, single-line display) until five total letters were missed on each chart. A repeated-measure ANOVA was used to compare the acuity measures between groups. The average logMAR VA for subjects with Down syndrome was approximately six lines worse than the control subjects (BL: Down syndrome = right eye: 0.51 ± 0.16, left eye: 0.53 ± 0.18; control = right eye: -0.06 ± 0.06, left eye: -0.06 ± 0.08, P < .0001; HOTV: Down syndrome = right eye: 0.47 ± 0.19, left eye: 0.46 ± 0.16; control: right eye = -0.11 ± 0.09, left eye: -0.07 ± 0.07, P < .001). Bailey-Lovie VA repeatability (1.96 * Sw * √2) was 0.13 logMAR (6.5 letters) for Down syndrome and 0.09 logMAR (4.5 letters) for control subjects. HOTV VA repeatability was 0.16 logMAR (eight letters) for both Down syndrome and control subjects. Despite poorer acuity in individuals with Down syndrome, repeatability of VA measurements was comparable to control subjects for both BL and HOTV techniques.
Vision based flight procedure stereo display system
NASA Astrophysics Data System (ADS)
Shen, Xiaoyun; Wan, Di; Ma, Lan; He, Yuncheng
2008-03-01
A virtual reality flight procedure vision system is introduced in this paper. The digital flight map database is established based on the Geographic Information System (GIS) and high definitions satellite remote sensing photos. The flight approaching area database is established through computer 3D modeling system and GIS. The area texture is generated from the remote sensing photos and aerial photographs in various level of detail. According to the flight approaching procedure, the flight navigation information is linked to the database. The flight approaching area vision can be dynamic displayed according to the designed flight procedure. The flight approaching area images are rendered in 2 channels, one for left eye images and the others for right eye images. Through the polarized stereoscopic projection system, the pilots and aircrew can get the vivid 3D vision of the flight destination approaching area. Take the use of this system in pilots preflight preparation procedure, the aircrew can get more vivid information along the flight destination approaching area. This system can improve the aviator's self-confidence before he carries out the flight mission, accordingly, the flight safety is improved. This system is also useful in validate the visual flight procedure design, and it helps to the flight procedure design.
ERIC Educational Resources Information Center
Yuzer, T. Volkan
2007-01-01
The Internet usage has been increasing among persons in the worldwide. This situation highlights that the number of potential distance learners has been increasing in the Internet society. Besides, the terms and concepts of the Internet environments become to be spread out in this society like virtual reality. It is also possible to explain the…
Sun, I-Ting; Lee, Tsung-Han; Chen, Chih-Hsin
2017-01-01
Purpose We report a case of rapid cataract progression after Nd:YAG vitreolysis for vitreous floaters. Case Report A 55-year-old man presented with acute onset of blurred vision following Nd:YAG vitreolysis for symptomatic floaters in the left eye. His initial best corrected visual acuity (BCVA) was 20/1,000 in the left eye. Ocular examinations showed frost-like opacities of the lens and a suspected break of the posterior capsule in the left eye. There were no detectable retinal lesions. Cataract surgery was then arranged. Posterior capsular rupture and vitreous loss occurred during surgery, which required a subsequent pars plana vitrectomy. After the surgery, BCVA in the left eye gradually improved to 20/20 and was maintained during a 1-year follow-up period. Conclusion Crystalline lens injuries and rapid cataract progression may occur following Nd:YAG vitreolysis. While dealing with this type of complicated cataract, clinicians should be aware of the possibility of posterior lens capsule rupture during surgery and the need for combined vitrectomy. PMID:28626418
Kharel Sitaula, Ranju; Joshi, Sagun Narayan; Sah, Ranjit; Khadka, Sushila; Khatri Kc, Anadi; Pokharel, Bharat Mani
2018-06-15
Detection of Toxoplasma gondii cysts in vitreous of immunocompetent patient with necrotizing retinitis is extremely rare. We herein report the isolation of Toxoplasma bradyzoites and tachyzoites from the vitreous of healthy person. A 19-year-old immunocompetent female presented with sudden loss of vision in left eye since 1 week. The BCVA was 6/6 and HM in right and left eye. The left eye finding was suggestive of diffuse necrotizing retinitis with retinal detachment. The IgM and IgG for TORCH infection were negative and HIV, HCV and HBsAg tests were also non reactive. The patient underwent diagnostic and therapeutic vitrectomy with silicon oil installation. The vitreous toxoplasma IgG titre was found to be significantly raised to 1:16. Bradyzoites of toxoplasma were identified in H&E staining and tachyzoites of Toxoplasma were identified in Giemsa staining of vitreous sample. She received oral clindamycin and oral corticosteroid but the vision could not be restored in left eye. Hence, atypical toxoplasmosis with necrotizing retinitis is a fulminant condition with the diagnostic and therapeutic challenge.
More than meets the eye: the 'pink salmon patch'.
Pallavi, Ranjita; Popescu-Martinez, Andrea
2014-08-28
Ocular adnexal lymphomas account for 1-2% of all non-Hodgkin's lymphomas. Conjunctiva is the primary site of involvement in one-third of cases. We present a case of a 47-year-old Hispanic woman who presented with left eye itching and irritation associated with a painless pink mass. Physical examination revealed the presence of a 'pink salmon-patch' involving her left medial conjunctiva. Orbital CT showed a subcentimeter left preseptal soft tissue density. Biopsy revealed a dense subepithelial lymphoid infiltrate comprised predominantly of B cells that did not coexpress CD5 or CD43. These findings were consistent with B-cell marginal zone lymphoma. Further staging assessment did not reveal disseminated disease. She had stage 1E extranodal marginal zone lymphoma as per Ann Arbor staging system. She received external beam radiotherapy to her left eye with complete resolution of the lymphoma in 2 months and continues to remain tumour free at 8-month follow-up. She will be followed up closely for development of any local (unilateral or contralateral eye) or systemic recurrence in the long run. 2014 BMJ Publishing Group Ltd.
Effects of astigmatic axis orientation on postural stabilization with stationary equilibrium
NASA Astrophysics Data System (ADS)
Kanazawa, Masatsugu; Uozato, Hiroshi; Asakawa, Ken; Kawamorita, Takushi
2018-02-01
We evaluated 15 healthy participants by assessing their maintenance of postural control while standing on a platform stabilometer for 1 min under the following conditions: eyes open; eyes open with + 3.00 D on both eyes on same directions (45, 90, 135, 180 degree axis); right eye on 45 degree axis and left eye on 135 degree axis (inverted V-pattern), and right eye on 135 degree axis and left eye on axis 45 degree axis (V-pattern). The differences in the linear length, area and maximum velocity of center of pressure during postural control before and after the six types of positive cylinder-oriented axes were analyzed. Comparing the antero-posterior lengths and antero-posterior maximum velocities, there were significant differences between the V-pattern condition and the six other conditions. Astigmatic defocus in the antagonistic axes conditions, particularly the V-pattern condition, affects postural control of antero-posterior sway (143/150).
Lateral eye-movement responses to visual stimuli.
Wilbur, M P; Roberts-Wilbur, J
1985-08-01
The association of left lateral eye-movement with emotionality or arousal of affect and of right lateral eye-movement with cognitive/interpretive operations and functions was investigated. Participants were junior and senior students enrolled in an undergraduate course in developmental psychology. There were 37 women and 13 men, ranging from 19 to 45 yr. of age. Using videotaped lateral eye-movements of 50 participants' responses to 15 visually presented stimuli (precategorized as neutral, emotional, or intellectual), content and statistical analyses supported the association between left lateral eye-movement and emotional arousal and between right lateral eye-movement and cognitive functions. Precategorized visual stimuli included items such as a ball (neutral), gun (emotional), and calculator (intellectual). The findings are congruent with existing lateral eye-movement literature and also are additive by using visual stimuli that do not require the explicit response or implicit processing of verbal questioning.
Dry Eye Post-Laser-Assisted In Situ Keratomileusis: Major Review and Latest Updates
Spierer, Oriel
2018-01-01
Dry eye is one of the most common complications occurring after laser-assisted in situ keratomileusis (LASIK), with virtually all patients experiencing some degree of postoperative dry eye symptoms. Enhanced understanding of the pathophysiology and mechanism of dry eye development in addition to preoperative screening of patients who are prone to dry eye is essential for better patient satisfaction and for improving short-term visual outcome postoperatively. This article reviews the latest studies published on LASIK-associated dry eye, including epidemiology, pathophysiology, risk factors, preoperative assessment, and management. PMID:29619255
Lachrymal Gland Basal Cell Adenocarcinoma in a Ferret (Mustela putorius furo).
Chambers, J K; Nakamori, T; Kishimoto, T E; Nakata, M; Miwa, Y; Nakayama, H; Uchida, K
2016-01-01
A 1 cm diameter mass was detected in the caudal superotemporal area of the left eye of a 6-year-old neutered male ferret (Mustela putorius furo). The mass and the left eye were removed surgically. Microscopical examination revealed a tumour of the adnexal gland of the eye that had invaded the surrounding ocular muscle. The tumour was composed of basal-type epithelial cells arranged in a solid, or occasionally tubular, pattern. Immunohistochemically, the tumour cells expressed cytokeratin and p63, but not smooth muscle actin. Based on these findings, the tumour was diagnosed as a basal cell adenocarcinoma of the lachrymal gland. In addition to the tumour, the retina of the left eye was detached and folded at the centre of the globe. This is the first report of a non-human case of basal cell adenocarcinoma of the lachrymal gland. Copyright © 2016 Elsevier Ltd. All rights reserved.
Retinal venous thrombosis in a young patient with coagulation factor XII deficiency.
Borrego-Sanz, L; Santos-Bueso, E; Sáenz-Francés, F; Martínez-de-la-Casa, J M; García-Feijoo, J; Gegúndez-Fernández, J A; García-Sánchez, J
2014-08-01
A 35-year-old woman, with no relevant medical history, was referred for sudden vision loss in the left eye. Ophthalmological examination showed best corrected visual acuity of 1.0 in the right eye and 0.3 in left eye, with normal anterior pole and intraocular pressure. Fundus examination of the left eye revealed a venous thrombosis in the superior temporal branch, with dilated and tortuous retinal veins. The patient was referred to the hematology unit for thrombophilia study, and was diagnosed with a coagulation XII or Hageman factor deficiency. The development of retinal vessel occlusions, in patients under 50 years of age, is frequently associated with thrombophilia or hypercoagulability disorders. Factor XII deficiency is a rare condition, and its presence could contribute to a higher risk of thromboembolic events. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Shtein, Roni M
2011-01-01
Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730
LASIK flap characteristics using the Moria M2 microkeratome with the 90-microm single use head.
Aslanides, Ioannis M; Tsiklis, Nikolaos S; Astyrakakis, Nikolaos I; Pallikaris, Ioannis G; Jankov, Mirko R
2007-01-01
To evaluate the accuracy and consistency of corneal flap thickness, horizontal diameter, and hinge size with the Moria M2 90-microm single use head. Fifty-two myopic patients (104 eyes), mean age 32.6 years, underwent bilateral LASIK with a superior hinged flap using the Moria M2 microkeratome (90-microm single use head). Prospective evaluation included flap thickness (subtraction method), diameter, hinge size, interface particles, intraoperative complications, and visual recovery. The mean preoperative spherical equivalent refraction was -5.72 +/- 2.59 diopters (D) (range: -2.88 to -10.75 D) and -5.84 +/- 2.73 D (range: -3.13 to -9.38 D) for right and left eyes, respectively. The mean preoperative central corneal thickness was 548 +/- 24 microm and 547 +/- 25 microm for right and left eyes, respectively. The mean preoperative steepest K was 44.12 +/- 1.28 D and 44.41 +/- 1.27 D for right and left eyes, respectively. Corneal diameter (white-to-white) was 12 +/- 0.4 mm and 11.9 +/- 0.4 mm for right and left eyes, respectively. The mean postoperative flap thickness was 109 +/- 18 microm (range: 67 to 152 microm) and 103 +/- 15 microm (range: 65 to 151 microm) for right and left eyes, respectively. The mean postoperative flap diameter was 9.4 +/- 0.3 mm (expected mean according to the nomogram given by the company was 9.5 mm). The mean postoperative hinge chord was 4.4 +/- 0.4 mm (expected mean 4.2 mm). No interface particles were detected on slit-lamp examination. The Moria M2 90-microm single use head is safe with reasonable predictability for LASIK flap creation.
Advanced autostereoscopic display for G-7 pilot project
NASA Astrophysics Data System (ADS)
Hattori, Tomohiko; Ishigaki, Takeo; Shimamoto, Kazuhiro; Sawaki, Akiko; Ishiguchi, Tsuneo; Kobayashi, Hiromi
1999-05-01
An advanced auto-stereoscopic display is described that permits the observation of a stereo pair by several persons simultaneously without the use of special glasses and any kind of head tracking devices for the viewers. The system is composed of a right eye system, a left eye system and a sophisticated head tracking system. In the each eye system, a transparent type color liquid crystal imaging plate is used with a special back light unit. The back light unit consists of a monochrome 2D display and a large format convex lens. The unit distributes the light of the viewers' correct each eye only. The right eye perspective system is combined with a left eye perspective system is combined with a left eye perspective system by a half mirror in order to function as a time-parallel stereoscopic system. The viewer's IR image is taken through and focused by the large format convex lens and feed back to the back light as a modulated binary half face image. The auto-stereoscopic display employs the TTL method as the accurate head tracking. The system was worked as a stereoscopic TV phone between Duke University Department Tele-medicine and Nagoya University School of Medicine Department Radiology using a high-speed digital line of GIBN. The applications are also described in this paper.
Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.
Camesasca, Fabrizio I; Vinciguerra, Paolo; Seiler, Theo
2011-12-01
To report a case of bilateral, ring-shaped, intrastromal corneal opacities after corneal cross-linking (CXL) for progressive keratoconus. A 21-year-old man with bilateral, progressive keratoconus underwent CXL with riboflavin 0.1% and ultraviolet A (UVA) light in the right eye and, 6 months later, in the left eye. One day after CXL, the right eye showed a sharply demarcated white ring in the corneal periphery. The ring involved the superficial stroma at 2 mm from the limbus, extended from 1 to 11 o'clock, and was 1.5-mm wide. Corneal topography showed marked central flattening. Six months after treatment, a residual, faint, ring-shaped opacity remained, with a decrease in corneal ectasia. Cross-linking was then performed in the left eye. Different ultraviolet devices were used in the two eyes. On postoperative day 1, the left eye also showed a white ring of stromal opacity. Scheimpflug imaging showed corneal stromal contraction in the zone of whitening. At final examination, >1 year after surgery, corrected visual acuity was 0.00 logMAR with cylinder of 2.00 diopters in both eyes. The bilateral intrastromal corneal changes were innocuous in the long-term, with preservation of good visual acuity and successful stabilization of progressive keratoconus.
Ultrasonographic biometry of the normal eye of the Persian cat.
Mirshahi, A; Shafigh, S H; Azizzadeh, M
2014-07-01
To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.
Normative database of donor keratographic readings in an eye-bank setting.
Lewis, Jennifer R; Bogucki, Jennifer M; Mahmoud, Ashraf M; Lembach, Richard G; Roberts, Cynthia J
2010-04-01
To generate a normative donor topographic database from rasterstereography images of whole globes acquired in an eye-bank setting with minimal manipulation or handling. Eye-bank laboratory. In a retrospective study, rasterstereography topographic images that had been prospectively collected in duplicate of donor eyes received by the Central Ohio Lions Eye Bank between 1997 and 1999 were analyzed. Best-fit sphere (BFS) and simulated keratometry (K) values were extracted. These values were recalculated after application of custom software to correct any tilt of the mapped surfaces relative to the image plane. The mean value variances between right eyes and left eyes, between consecutive scans, and after untilting were analyzed by repeated-measures analysis of variance and t tests (P
Eye laterality: a comprehensive analysis in refractive surgery candidates.
Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam
2013-08-01
To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p < 0.001). Subgroup analysis revealed (I) right eye laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.
Hampstead, B M; Khoshnoodi, M; Yan, W; Deshpande, G; Sathian, K
2016-01-01
Previous research has shown that there is considerable overlap in the neural networks mediating successful memory encoding and retrieval. However, little is known about how the relevant human brain regions interact during these distinct phases of memory or how such interactions are affected by memory deficits that characterize mild cognitive impairment (MCI), a condition that often precedes dementia due to Alzheimer's disease. Here we employed multivariate Granger causality analysis using autoregressive modeling of inferred neuronal time series obtained by deconvolving the hemodynamic response function from measured blood oxygenation level-dependent (BOLD) time series data, in order to examine the effective connectivity between brain regions during successful encoding and/or retrieval of object location associations in MCI patients and comparable healthy older adults. During encoding, healthy older adults demonstrated a left hemisphere dominant pattern where the inferior frontal junction, anterior intraparietal sulcus (likely involving the parietal eye fields), and posterior cingulate cortex drove activation in most left hemisphere regions and virtually every right hemisphere region tested. These regions are part of a frontoparietal network that mediates top-down cognitive control and is implicated in successful memory formation. In contrast, in the MCI patients, the right frontal eye field drove activation in every left hemisphere region examined, suggesting reliance on more basic visual search processes. Retrieval in the healthy older adults was primarily driven by the right hippocampus with lesser contributions of the right anterior thalamic nuclei and right inferior frontal sulcus, consistent with theoretical models holding the hippocampus as critical for the successful retrieval of memories. The pattern differed in MCI patients, in whom the right inferior frontal junction and right anterior thalamus drove successful memory retrieval, reflecting the characteristic hippocampal dysfunction of these patients. These findings demonstrate that neural network interactions differ markedly between MCI patients and healthy older adults. Future efforts will investigate the impact of cognitive rehabilitation of memory on these connectivity patterns. Published by Elsevier Inc.
Relation Between Near Work and Myopia Progression in Student Population
Muhamedagic, Lejla; Muhamedagic, Belma; Halilovic, Emina Alimanovic; Halimic, Jasmina Alajbegovic; Stankovic, Aleksa; Muracevic, Bedrana
2014-01-01
Aim To determine relation between near work and myopia progression in student population. Causes of myopia occurrence are not sufficiently explained. Methods This retrospective-prospective, descriptive research included 100 students with verified myopia up to -3 Dsph. Ophthalmological examination and measurement diopter-hours variable (Dh) were done twice, in the period from January 2011 until January 2012. Results A multivariate regression analysis of impact on the difference of distance visual acuity without correction to the right and left eye and difference of automatic computer refractometry in cycloplegia of both eyes indicates that, diopter-hours variable (Dh) had statistically significant impact on increase of distance visual acuity difference (right eye OR: I measurement–Dh 1.489, II measurement–Dh 1.544, p<0.05; left eye OR: I measurement–Dh 1.602, II measurement–Dh 1.538, p<0.05) and automatic computer refractometry in cycloplegia (right eye OR: I measurement 1.361, II measurement 1.493, p<0.05; left eye OR: I measurement 0.931, II measurement 1.019, p<0.05) during both measurements. Conclusion Near work cause the increase of myopia. This research opened a perspective for other researches on the impact of near work on myopia. PMID:24944532
Lee, Chang Mok; Hong, In Hwan; Park, Sung Pyo
2011-10-01
We report a case of ophthalmic artery obstruction combined with brain infarction following periocular autologous fat injection. The patient, a 44-year-old woman, visited our hospital for decreased visual acuity in her left eye and dysarthria one hour after receiving an autologous fat injection in the periocular area. Her best corrected visual acuity for the concerned eye was no light perception. Also, a relative afferent pupillary defect was detected in this eye. The left fundus exhibited widespread retinal whitening with visible emboli in several retinal arterioles. Diffusion-weighted magnetic resonance imaging of the brain showed a hyperintense lesion at the left insular cortex. Therefore, we diagnosed ophthalmic artery obstruction and left middle cerebral artery infarction due to fat emboli. The patient was managed with immediate ocular massage, carbon dioxide, and oxygen therapy. Following treatment, dysarthria improved considerably but there was no improvement in visual acuity.
Thomas, Nicole A; Wignall, Sophie J; Loetscher, Tobias; Nicholls, Michael E R
2014-10-01
Quick and accurate judgments of emotional expressivity and attractiveness facilitate social interactions. Eye tracking was used to examine left/right asymmetries across 2 studies. Fixations to each hemiface, and to the eyes and mouth, when judging attractiveness and emotional expressivity were examined. Overall, more fixations occurred on the left hemiface (from the viewer's point of view), even when mirror-reversed, supporting the suggestion that we intuitively know the left hemiface is more expressive. The right side of the mouth was fixated more when judging happiness, whereas the left eye was fixated more for sadness and the left mouth when rating emotional expressivity. The present findings support the notion that the right hemisphere and valence-specific hypotheses are not mutually exclusive. The right hemisphere hypothesis is supported when assessing global facial qualities (i.e., hemiface); however, hemispheric processing differences emerge when exploring the eyes and mouth. The current findings highlight the importance of not only considering how the face is examined more generally, but of also exploring smaller regions of interest to investigate lateral biases. Future research should therefore include analyses of fixations to the hemifaces, as well as to these smaller regions of interest. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Attention to gaze and emotion in schizophrenia.
Schwartz, Barbara L; Vaidya, Chandan J; Howard, James H; Deutsch, Stephen I
2010-11-01
Individuals with schizophrenia have difficulty interpreting social and emotional cues such as facial expression, gaze direction, body position, and voice intonation. Nonverbal cues are powerful social signals but are often processed implicitly, outside the focus of attention. The aim of this research was to assess implicit processing of social cues in individuals with schizophrenia. Patients with schizophrenia or schizoaffective disorder and matched controls performed a primary task of word classification with social cues in the background. Participants were asked to classify target words (LEFT/RIGHT) by pressing a key that corresponded to the word, in the context of facial expressions with eye gaze averted to the left or right. Although facial expression and gaze direction were irrelevant to the task, these facial cues influenced word classification performance. Participants were slower to classify target words (e.g., LEFT) that were incongruent to gaze direction (e.g., eyes averted to the right) compared to target words (e.g., LEFT) that were congruent to gaze direction (e.g., eyes averted to the left), but this only occurred for expressions of fear. This pattern did not differ for patients and controls. The results showed that threat-related signals capture the attention of individuals with schizophrenia. These data suggest that implicit processing of eye gaze and fearful expressions is intact in schizophrenia. (c) 2010 APA, all rights reserved
Outbreak of diffuse lamellar keratitis caused by marking-pen toxicity.
Hadden, Osmond Bruce; McGhee, Charles N J; Morris, Antony Trevor; Gray, Trevor Buchanan; Ring, Charles Peter; Watson, Adam Stewart John
2008-07-01
To examine the evidence that a series of cases of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) was caused by a type of marker pen. Eye Institute, Auckland, New Zealand. During a 10-week period, 522 consecutive LASIK procedures were performed using a 60 Hz IntraLase femtosecond laser (IntraLase Corp.) to create the LASIK flap and a 217Z 100 Hz excimer laser (Bausch & Lomb) to perform the refractive ablation. As standard practice, a marking pen was used to enable accurate flap realignment. Three weeks after a sudden increase in the incidence of DLK was identified, one of the 5 surgeons performed 5 consecutive bilateral cases using the marking pen in the right eyes but not in the left eyes. Of the 522 LASIK cases (119 without marking pen, 403 with marking pen), DLK developed in 49 (9.4%). No eye treated without the marking pen developed DLK; of those in which the marking pen was used, 49 (12.2%) developed DLK (P<0.0001, Fischer exact test; odds ratio, 27). In the 5 consecutive bilateral cases in which the marking pen was used in the right eye but not the left eye, 4 right eyes and no left eye developed DLK (P=0.03). Forty-five of the 49 eyes with DLK quickly recovered. The other 4 developed central toxic keratopathy. There is strong statistical evidence that the marking pen was a factor in the occurrence of DLK.
[Local cyclosporin A therapy of nummuli after epidemic keratoconjunctivitis--case report].
Reinhard, T; Sundmacher, R
1997-03-01
Steroid therapy for persistent or recurrent nummular adenoviral keratoconjunctivitis (AK) has little benefit because of the frequent recurrences, and mostly "offers" only serious steroid side effects. Since January 1995, we have treated different patients with nummuli after AK with topical Ciclosporin A (CSA) in an attempt to achieve at least the same symptomatic effect as with steroids, however, without side effects. Here, we report about our experiences in a very severe case with longterm treatment. The patient was sent to our clinic 4 months after AK with confluent nummuli and Descemet folds, more severe in the right than in the left eye. Best corrected visual acuity was 0.05 in the right and 0.5 in the left eye. Topical CSA 2% 4 times daily was first administered only in the right eye. When after 6 weeks a reduction of nummuli was noted in the right eye, the left eye, which had not improved, was started on the same regime. Therapy was tapered and finally stopped after 12 months in the right and 10 months in the left eye, when only minor changes were left in the corneae. A prompt recurrence of nummuli in both eyes within 4 weeks forced us to resume CSA therapy. At present, both corneae are clear with full vision, and this result is stable with 1 drop of CSA daily. No side effects of CSA therapy have been noted. The disappearance of nummuli with topical CSA and even more the reappearance of nummuli after cessation of CSA therapy show that topical CSA is about as effective as topical steroids in the symptomatic treatment of non-scarred nummuli after KE without the serious steroid side effects. Topical CSA treatment of nummuli after KE is, therefore, a very recommendable alternative for the potentially dangerous steroid therapy. Generally valid data on risk of recurrences, dosage and general effectiveness could only be learned from prospective studies with large numbers of AK patients, which, however, are not available outside epidemics.
Real-time eye lens dose monitoring during cerebral angiography procedures.
Safari, M J; Wong, J H D; Kadir, K A A; Thorpe, N K; Cutajar, D L; Petasecca, M; Lerch, M L F; Rosenfeld, A B; Ng, K H
2016-01-01
To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.
Zhao, Jing; Zhao, Feng; Huang, Jinrong; Xu, Haipeng; Chen, Yingjun; Zhou, Xingtao
2018-04-01
To describe a patient with flap complications after LASIK who was subsequently treated using phototherapeutic keratectomy (PTK) and an autologous lenticule transplant obtained via small incision lenticule extraction (SMILE). A 23-year-old man experienced free flap and partial flap loss in the left eye following LASIK, resulting in corneal stroma opacity 1 month later. The manifest refraction was -3.25 diopters sphere (DS)/-0.50 diopters cylinder (DC) × 100° in the right eye and +2.50 DS/-1.25 DC × 155° in the left eye. His left eye was treated with PTK and transplantation of an autologous lenticule obtained from his right eye using the SMILE procedure. At the 2-year follow-up visit, the uncorrected distance visual acuity of the left eye had improved from 20/100 to 20/22 and the corrected distance visual acuity had improved from 20/25 to 20/18. Central corneal thickness had increased from 464 to 499 µm. The mean keratometry value had decreased from 45.00 diopters (D) at the 1-month follow-up visit to 39.40 D at the 2-year follow-up visit. Optical coherence tomography examination revealed that the lenticule remained transparent and exhibited a visible demarcation line. The transplantation of an autologous lenticule obtained via SMILE combined with PTK improved uncorrected and corrected acuity in this patient with flap loss after LASIK. [J Refract Surg. 2018;34(4):281-285.]. Copyright 2018, SLACK Incorporated.
Visual and somatic sensory feedback of brain activity for intuitive surgical robot manipulation.
Miura, Satoshi; Matsumoto, Yuya; Kobayashi, Yo; Kawamura, Kazuya; Nakashima, Yasutaka; Fujie, Masakatsu G
2015-01-01
This paper presents a method to evaluate the hand-eye coordination of the master-slave surgical robot by measuring the activation of the intraparietal sulcus in users brain activity during controlling virtual manipulation. The objective is to examine the changes in activity of the intraparietal sulcus when the user's visual or somatic feedback is passed through or intercepted. The hypothesis is that the intraparietal sulcus activates significantly when both the visual and somatic sense pass feedback, but deactivates when either visual or somatic is intercepted. The brain activity of three subjects was measured by the functional near-infrared spectroscopic-topography brain imaging while they used a hand controller to move a virtual arm of a surgical simulator. The experiment was performed several times with three conditions: (i) the user controlled the virtual arm naturally under both visual and somatic feedback passed, (ii) the user moved with closed eyes under only somatic feedback passed, (iii) the user only gazed at the screen under only visual feedback passed. Brain activity showed significantly better control of the virtual arm naturally (p<;0.05) when compared with moving with closed eyes or only gazing among all participants. In conclusion, the brain can activate according to visual and somatic sensory feedback agreement.
Gattoussi, Sarra; Boon, Camiel J F; Freund, K Bailey
2017-08-10
We describe the long-term follow-up of a patient with multifocal Best disease with chronic bilateral serous macular detachment and unusual peripheral findings associated with a novel mutation in the BEST1 gene. Case report. A 59-year-old white woman was referred for an evaluation of her macular findings in 1992. There was a family history of Best disease in the patient's mother and a male sibling. Her medical history was unremarkable. Best-corrected visual acuity was 20/20 in her right eye and 20/25 in her left eye. The anterior segment examination was normal in both eyes. Funduscopic examination showed multifocal hyperautofluorescent vitelliform deposits with areas of subretinal fibrosis in both eyes. An electrooculogram showed Arden ratios of 1.32 in the right eye and 1.97 in the left eye. Ultra-widefield color and fundus autofluorescence imaging showed degenerative retinal changes in areas throughout the entire fundus in both eyes. Optical coherence tomography, including annual eye-tracked scans from 2005 to 2016, showed persistent bilateral serous macular detachments. Despite chronic foveal detachment, visual acuity was 20/25 in her right eye and 20/40 in her left eye, 24 years after initial presentation. Genetic testing showed a novel c.238T>A (p.Phe80Ile) missense mutation in the BEST1 gene. Some patients with Best disease associated with chronic serous macular detachment can maintain good visual acuity over an extended follow-up. To our knowledge, this is the first report of Best disease associated with this mutation in the BEST1 gene.
75 FR 59793 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-28
.... Joel W. Bryant Mr. Bryant, 53, has had a prosthetic right eye since 1990 due to a traumatic injury. The..., sustained traumatic injury to his left optic nerve at age 14. The best corrected visual acuity in his right... ruptured globe in his left eye due to a traumatic injury sustained in 2005. The best corrected visual...
77 FR 20879 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-06
... loss of vision in his right due to a traumatic injury sustained at age 9. The visual acuity in his left... due to a traumatic injury sustained in 1989. The best corrected visual acuity in his right eye is 20... traumatic injury sustained 10 years ago. The visual acuity in his left eye is 20/20. Following an...
Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays.
Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Cooper, Emily A; Wetzstein, Gordon
2017-02-28
From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one.
Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays
NASA Astrophysics Data System (ADS)
Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Cooper, Emily A.; Wetzstein, Gordon
2017-02-01
From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one.
Interesting case of base of skull mass infiltrating cavernous sinuses.
Singh, Achintya Dinesh; Soneja, Manish; Memon, Saba Samad; Vyas, Surabhi
2016-11-16
A man aged 35 years presented with chronic headache and earache of 1-year duration. He had progressive vision loss and diplopia since last 9 months. He also had pain over the face and episodic profuse epistaxis. On examination, perception of light was absent in the right eye and hand movements were detected at 4 m distance in the left eye. Imaging revealed a lobulated mass in the nasopharynx extending into the bilateral cavernous sinuses and sphenoid sinus with bony erosions. Biopsy of the nasopharyngeal mass revealed pathological features which are characteristic of IgG4 disease. His serum IgG4 levels and acute inflammatory markers were also elevated. The patient was started on oral corticosteroid therapy. Fever, headache and earache resolved early and there was gradual improvement in the vision of the left eye. After 6 months, visual acuity in the left eye was 6/9, but right eye visual acuity had no change. Follow-up imaging revealed a significant reduction in the size of the mass. 2016 BMJ Publishing Group Ltd.
Wu, Shang-Lin; Liao, Lun-De; Lu, Shao-Wei; Jiang, Wei-Ling; Chen, Shi-An; Lin, Chin-Teng
2013-08-01
Electrooculography (EOG) signals can be used to control human-computer interface (HCI) systems, if properly classified. The ability to measure and process these signals may help HCI users to overcome many of the physical limitations and inconveniences in daily life. However, there are currently no effective multidirectional classification methods for monitoring eye movements. Here, we describe a classification method used in a wireless EOG-based HCI device for detecting eye movements in eight directions. This device includes wireless EOG signal acquisition components, wet electrodes and an EOG signal classification algorithm. The EOG classification algorithm is based on extracting features from the electrical signals corresponding to eight directions of eye movement (up, down, left, right, up-left, down-left, up-right, and down-right) and blinking. The recognition and processing of these eight different features were achieved in real-life conditions, demonstrating that this device can reliably measure the features of EOG signals. This system and its classification procedure provide an effective method for identifying eye movements. Additionally, it may be applied to study eye functions in real-life conditions in the near future.
Bulbar conjunctival sporotrichosis presenting as a salmon-pink tumor.
Kashima, Tomoyuki; Honma, Rika; Kishi, Shoji; Hirato, Junko
2010-05-01
To report a patient with bulbar conjunctival sporotrichosis presenting as a salmon-pink tumor. This was an interventional case report. A 62-year-old woman presented with conjunctival injection in her left eye. Despite administration of topical dexamethasone sodium, ofloxacin, and levocabastine hydrochloride, her symptoms failed to improve and she was referred to us. Four weeks after referral to us, the patient gradually developed conjunctival injection in both eyes and a salmon-pink tumor in the bulbar conjunctiva of the left eye. Excision biopsy was performed and pathologic examination revealed an epithelioid granuloma with microabscesses and infiltration of plasma cells with yeast-like spherules. A sporotrichin intradermal test was strongly positive. Based on a diagnosis of sporotrichosis, we treated her with topical fluconazole 0.2% in both eyes and oral potassium iodide (450 mg). The bilateral conjunctival injection and subconjunctival tumor in the left eye gradually resolved and had completely disappeared after 3 months of treatment. This is the first report of bulbar conjunctival sporotrichosis with a salmon-pink conjunctival tumor. Although rare, ophthalmologists should be aware of this entity during examination of patients with intractable conjunctival injection.
Reaction time for processing visual stimulus in a computer-assisted rehabilitation environment.
Sanchez, Yerly; Pinzon, David; Zheng, Bin
2017-10-01
To examine the reaction time when human subjects process information presented in the visual channel under both a direct vision and a virtual rehabilitation environment when walking was performed. Visual stimulus included eight math problems displayed on the peripheral vision to seven healthy human subjects in a virtual rehabilitation training (computer-assisted rehabilitation environment (CAREN)) and a direct vision environment. Subjects were required to verbally report the results of these math calculations in a short period of time. Reaction time measured by Tobii Eye tracker and calculation accuracy were recorded and compared between the direct vision and virtual rehabilitation environment. Performance outcomes measured for both groups included reaction time, reading time, answering time and the verbal answer score. A significant difference between the groups was only found for the reaction time (p = .004). Participants had more difficulty recognizing the first equation of the virtual environment. Participants reaction time was faster in the direct vision environment. This reaction time delay should be kept in mind when designing skill training scenarios in virtual environments. This was a pilot project to a series of studies assessing cognition ability of stroke patients who are undertaking a rehabilitation program with a virtual training environment. Implications for rehabilitation Eye tracking is a reliable tool that can be employed in rehabilitation virtual environments. Reaction time changes between direct vision and virtual environment.
Marschner, Linda; Pannasch, Sebastian; Schulz, Johannes; Graupner, Sven-Thomas
2015-08-01
In social communication, the gaze direction of other persons provides important information to perceive and interpret their emotional response. Previous research investigated the influence of gaze by manipulating mutual eye contact. Therefore, gaze and body direction have been changed as a whole, resulting in only congruent gaze and body directions (averted or directed) of another person. Here, we aimed to disentangle these effects by using short animated sequences of virtual agents posing with either direct or averted body or gaze. Attention allocation by means of eye movements, facial muscle response, and emotional experience to agents of different gender and facial expressions were investigated. Eye movement data revealed longer fixation durations, i.e., a stronger allocation of attention, when gaze and body direction were not congruent with each other or when both were directed towards the observer. This suggests that direct interaction as well as incongruous signals increase the demands of attentional resources in the observer. For the facial muscle response, only the reaction of muscle zygomaticus major revealed an effect of body direction, expressed by stronger activity in response to happy expressions for direct compared to averted gaze when the virtual character's body was directed towards the observer. Finally, body direction also influenced the emotional experience ratings towards happy expressions. While earlier findings suggested that mutual eye contact is the main source for increased emotional responding and attentional allocation, the present results indicate that direction of the virtual agent's body and head also plays a minor but significant role. Copyright © 2015 Elsevier B.V. All rights reserved.
Virtual performer: single camera 3D measuring system for interaction in virtual space
NASA Astrophysics Data System (ADS)
Sakamoto, Kunio; Taneji, Shoto
2006-10-01
The authors developed interaction media systems in the 3D virtual space. In these systems, the musician virtually plays an instrument like the theremin in the virtual space or the performer plays a show using the virtual character such as a puppet. This interactive virtual media system consists of the image capture, measuring performer's position, detecting and recognizing motions and synthesizing video image using the personal computer. In this paper, we propose some applications of interaction media systems; a virtual musical instrument and superimposing CG character. Moreover, this paper describes the measuring method of the positions of the performer, his/her head and both eyes using a single camera.
Bilateral Mycobacterium chelonae Keratitis after Phacoemulsification Cataract Surgery.
Martinez, Jaime D; Amescua, Guillermo; Lozano-Cárdenas, Jesus; Suh, Leejee H
2017-01-01
The purpose of this manuscript is to report the case of an 81-year-old patient who presented with bilateral keratitis after phacoemulsification surgery. Cultures came back positive for Mycobacterium chelonae . Despite aggressive topical and systemic antimicrobial treatment, the patient developed a corneal perforation in both eyes, treated with corneal glue in the right eye and corneoscleral patch in the left eye. After two years of follow-up, patient was free of infection in the right eye with visual acuity of 20/200 and the left eye progressed to phthisis bulbi. We present an unusual case of bilateral Mycobacterium chelonae keratitis associated with phacoemulsification cataract surgery. This case represents the importance of making clinicians aware of this devastating infection and highlights the need for better management to improve outcomes.
[Myelinated nerve fibers coexisted with epiretinal membrane in macula--case report].
Swiech-Zubilewicz, Anna; Bieliński, Paweł; Dolar-Szczasny, Joanna; Zarnowski, Tomasz
2012-01-01
We describe a case of peripapillary myelinated retinal nerve fibers complicated by epiretinal membrane in region of macula. 72 years old man was refered to our Clinic with suspicion of retinal detachment of right eye. Visual acuity of right eye was based to 0.05, in left eye was 0.5. IOP was normal in both eyes. In biomcroscopic evaluation the slight cortical cataract was observed in both eyes. Stereoscopic evaluation of right eye revealed the presence of massive peripapillary myelinated retinal nerve fibers and epiretinal membrane in the macula. In the left eye the less intense peripapillary myelinated retinal nerve fibers were noticed as well and the macular region was unchanged. With the use of OCT examination of the retina the presence of epiretinal membrane in the right eye was confirmed. OCT in the fellow eye presented an undisturbed foveal profile without any epiretinal abnormalities. Myelinated retinal nerve fibers can be complicated by epiretinal membrane. Probably the presence of macular pathologies depends on the extensions of nerve fibers. OCT examination is very helpful to give a proper diagnosis.
Virtual Reality Glasses and "Eye-Hands Blind Technique" for Microsurgical Training in Neurosurgery.
Choque-Velasquez, Joham; Colasanti, Roberto; Collan, Juhani; Kinnunen, Riina; Rezai Jahromi, Behnam; Hernesniemi, Juha
2018-04-01
Microsurgical skills and eye-hand coordination need continuous training to be developed and refined. However, well-equipped microsurgical laboratories are not so widespread as their setup is expensive. Herein, we present a novel microsurgical training system that requires a high-resolution personal computer screen, smartphones, and virtual reality glasses. A smartphone placed on a holder at a height of about 15-20 cm from the surgical target field is used as the webcam of the computer. A specific software is used to duplicate the video camera image. The video may be transferred from the computer to another smartphone, which may be connected to virtual reality glasses. Using the previously described training model, we progressively performed more and more complex microsurgical exercises. It did not take long to set up our system, thus saving time for the training sessions. Our proposed training model may represent an affordable and efficient system to improve eye-hand coordination and dexterity in using not only the operating microscope but also endoscopes and exoscopes. Copyright © 2018 Elsevier Inc. All rights reserved.
Mukhopadhyaya, Udayaditya; Chakraborti, Chandana; Mondal, Anindita; Pattyanayak, Ujjal; Agarwal, Rajesh Kumar; Tripathi, Partha
2014-01-01
We report a 13-year-old child with Noonan Syndrome who developed spontaneous dislocation of the crystalline lens in anterior chamber leading to pupillary block glaucoma in the left eye and subluxation of lens in right eye. Intracapsular extraction of the dislocated lens was done in the left eye. Prompt diagnosis and management is needed in such cases to avoid glaucoma and corneal endothelial cell damage. We could not find any such case after thorough Medline search.
Goh, Rachel L Z; Kong, Yu Xiang George; McAlinden, Colm; Liu, John; Crowston, Jonathan G; Skalicky, Simon E
2018-01-01
To evaluate the use of smartphone-based virtual reality to objectively assess activity limitation in glaucoma. Cross-sectional study of 93 patients (54 mild, 22 moderate, 17 severe glaucoma). Sociodemographics, visual parameters, Glaucoma Activity Limitation-9 and Visual Function Questionnaire - Utility Index (VFQ-UI) were collected. Mean age was 67.4 ± 13.2 years; 52.7% were male; 65.6% were driving. A smartphone placed inside virtual reality goggles was used to administer the Virtual Reality Glaucoma Visual Function Test (VR-GVFT) to participants, consisting of three parts: stationary, moving ball, driving. Rasch analysis and classical validity tests were conducted to assess performance of VR-GVFT. Twenty-four of 28 stationary test items showed acceptable fit to the Rasch model (person separation 3.02, targeting 0). Eleven of 12 moving ball test items showed acceptable fit (person separation 3.05, targeting 0). No driving test items showed acceptable fit. Stationary test person scores showed good criterion validity, differentiating between glaucoma severity groups ( P = 0.014); modest convergence validity, with mild to moderate correlation with VFQ-UI, better eye (BE) mean deviation, BE pattern deviation, BE central scotoma, worse eye (WE) visual acuity, and contrast sensitivity (CS) in both eyes ( R = 0.243-0.381); and suboptimal divergent validity. Multivariate analysis showed that lower WE CS ( P = 0.044) and greater age ( P = 0.009) were associated with worse stationary test person scores. Smartphone-based virtual reality may be a portable objective simulation test of activity limitation related to glaucomatous visual loss. The use of simulated virtual environments could help better understand the activity limitations that affect patients with glaucoma.
Goh, Rachel L. Z.; McAlinden, Colm; Liu, John; Crowston, Jonathan G.; Skalicky, Simon E.
2018-01-01
Purpose To evaluate the use of smartphone-based virtual reality to objectively assess activity limitation in glaucoma. Methods Cross-sectional study of 93 patients (54 mild, 22 moderate, 17 severe glaucoma). Sociodemographics, visual parameters, Glaucoma Activity Limitation-9 and Visual Function Questionnaire – Utility Index (VFQ-UI) were collected. Mean age was 67.4 ± 13.2 years; 52.7% were male; 65.6% were driving. A smartphone placed inside virtual reality goggles was used to administer the Virtual Reality Glaucoma Visual Function Test (VR-GVFT) to participants, consisting of three parts: stationary, moving ball, driving. Rasch analysis and classical validity tests were conducted to assess performance of VR-GVFT. Results Twenty-four of 28 stationary test items showed acceptable fit to the Rasch model (person separation 3.02, targeting 0). Eleven of 12 moving ball test items showed acceptable fit (person separation 3.05, targeting 0). No driving test items showed acceptable fit. Stationary test person scores showed good criterion validity, differentiating between glaucoma severity groups (P = 0.014); modest convergence validity, with mild to moderate correlation with VFQ-UI, better eye (BE) mean deviation, BE pattern deviation, BE central scotoma, worse eye (WE) visual acuity, and contrast sensitivity (CS) in both eyes (R = 0.243–0.381); and suboptimal divergent validity. Multivariate analysis showed that lower WE CS (P = 0.044) and greater age (P = 0.009) were associated with worse stationary test person scores. Conclusions Smartphone-based virtual reality may be a portable objective simulation test of activity limitation related to glaucomatous visual loss. Translational Relevance The use of simulated virtual environments could help better understand the activity limitations that affect patients with glaucoma. PMID:29372112
Spontaneous closure of traumatic macular hole.
Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan
2012-07-01
Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases.
[Cytomegalovirus retinitis in immunocompetent patients].
Yoshinaga, Wakako; Mizushima, Yuka; Abematsu, Noriko; Nakao, Kumiko; Sakamoto, Taiji
2008-08-01
Cytomegalovirus (CMV) retinitis usually affects severely immunosuppressed individuals. We report two immunocompetent patients who developed CMV retinitis. Case 1 was a 65-year-old man who was referred to us with blurred vision and floaters of 2 weeks duration in his left eye. Slit-lamp biomicroscopy showed keratic precipitates, aqueous cells, and vitreous opacity in his left eye. Funduscopic examination revealed yellow-white retinal lesions with arterial sheathing in the superotemporal midperiphery. Case 2 was a 63-year-old man who presented with a 2-week history of blurred vision in his left eye. Ophthalmologic examination of the left eye showed keratic precipitates, aqueous cells, vitreous opacity, and yellow-white lesions in the superotemporal peripheral retina. In both cases, CMV DNA was detected in the aqueous humor and therefore the diagnosis was CMV retinitis. CMV retinitis in both cases was indolent and was resolved in one month without treatment with antiviral drugs. Although both patients had diabetes mellitus, the results of their laboratory examinations were unremarkable and they were immunocompetent. Unlike CMV retinitis in immunocompromised patients, CMV retinitis in immunocompetent patients had significant anterior and vitreous inflammation but did not require antiviral treatment. A possible association between CMV retinitis and diabetes mellitus was suggested.
Dust Devil in Spirit's View Ahead on Sol 1854 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11960 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11960 NASA's Mars Exploration Rover Spirit used its navigation camera to take the images that have been combined into this stereo, 180-degree view of the rover's surroundings during the 1,854th Martian day, or sol, of Spirit's surface mission (March 21, 2009). This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 13.79 meters (45 feet) westward earlier on Sol 1854. West is at the center, where a dust devil is visible in the distance. North on the right, where Husband Hill dominates the horizon; Spirit was on top of Husband Hill in September and October 2005. South is on the left, where lighter-toned rock lines the edge of the low plateau called 'Home Plate.' This view is presented as a cylindrical-perspective projection with geometric seam correction.Optic disc coloboma in two nigerian siblings: Case report and review of literature.
Babalola, Y O; Olawoye, O O; Idam, P O
2017-11-01
We report two cases of bilateral asymmetric optic disc coloboma (ODC) in siblings. The index patient is a 9-year-old Nigerian girl with severe cognitive deficit who presented with a poor vision of 3 years' duration. She had a history of childhood febrile convulsions and delayed developmental milestones. Her visual acuity could not be assessed because she had a cognitive deficit and expressive aphasia. Ocular examination revealed a very large excavated right optic disc with only a strip of remnant neuro-retinal rim superiorly, and a smaller left optic disc with inferior disc excavation, superior wedge of the pink neuro-retinal rim as well as a temporal optic disc pit. No systemic features of syndromes associated with ODCs and intellectual disability were present in both patients. The younger sibling an 8-year-old girl later presented to the eye clinic with a 5-month history of poor vision in the left eye. Ocular examination revealed visual acuity of 6/6 in the right eye and counting fingers in the left eye. Dilated binocular indirect ophthalmoscopy revealed a right large excavated colobomatous disc and a left small disc with infero-temporal disc coloboma.
A 3D virtual reality ophthalmoscopy trainer.
Wilson, Andrew S; O'Connor, Jake; Taylor, Lewis; Carruthers, David
2017-12-01
Performing eye examinations is an important clinical skill that medical students often find difficult to become proficient in. This paper describes the development and evaluation of an innovative 3D virtual reality (VR) training application to support learning these skills. The VR ophthalmoscope was developed by a clinical team and technologist using the unity game engine, smartphone and virtual reality headset. It has a series of tasks that include performing systematic eye examinations, identifying common eye pathologies and a knowledge quiz. As part of their clinical training, 15 fourth-year medical students were surveyed for their views on this teaching approach. The Technology Acceptance Model was used to evaluate perceived usefulness and ease of use. Data were also collected on the usability of the app, together with the students' written comments about it. Users agreed that the teaching approach improved their understanding of ophthalmoscopy (n = 14), their ability to identify landmarks in the eye (n = 14) and their ability to recognise abnormalities (n = 15). They found the app easy to use (n = 15), the teaching approach informative (n = 13) and that it would increase students' confidence when performing these tasks in future (n = 15). Performing eye examinations is an important clinical skill DISCUSSION: The evaluation showed that a VR app can successfully simulate the processes involved in performing eye examinations. The app was highly rated for all elements of perceived usefulness, ease of use and usability. Medical students stated that they would like to be taught other medical skills in this way in future. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
Sagara, Hideto; Sekiryu, Tetsuju; Noji, Hiroki; Ogasawara, Masashi; Imaizumi, Kimihiro; Yago, Keiko
2015-01-01
We present the case of a 47-year-old man who had bilateral proliferative diabetic retinopathy and neovascular glaucoma. Schirmer I test revealed tear secretions of 5 mm and 3 mm in the right and left eyes, respectively. Tear breakup times in the right and left eyes were 7 and 8 seconds, respectively. The ocular surface staining in both eyes was scored as Grade 1 as per the Oxford scheme. Retinal photocoagulation was performed for correction of the proliferative diabetic retinopathy and rubeosis iridis, which resolved with treatment. However, the intraocular pressure in the left eye could not be adequately controlled. Therefore, trabeculectomy with mitomycin C using limbal-based conjunctival flap was performed. Three hours after the surgery, the patient developed a large and diffuse filtering bleb, but no leakage occurred from the conjunctival scar. However, on the first postoperative day, leakage was noted and the conjunctiva was at the leakage point. The leakage resolved transiently, but recurred the next day. Severe keratoconjunctival epithelial failure was detected, and the patient was administrated 0.1% sodium hyaluronate eye drops six times daily. The epithelial failure improved, and many microcysts were detected on the bleb surface where the epithelial failure improved. The leakage resolved 2 days after initiation of the sodium hyaluronate eye drops. The microcysts disappeared and the bleb surface became smooth 1 month later. PMID:26664245
Sagara, Hideto; Sekiryu, Tetsuju; Noji, Hiroki; Ogasawara, Masashi; Imaizumi, Kimihiro; Yago, Keiko
2015-01-01
We present the case of a 47-year-old man who had bilateral proliferative diabetic retinopathy and neovascular glaucoma. Schirmer I test revealed tear secretions of 5 mm and 3 mm in the right and left eyes, respectively. Tear breakup times in the right and left eyes were 7 and 8 seconds, respectively. The ocular surface staining in both eyes was scored as Grade 1 as per the Oxford scheme. Retinal photocoagulation was performed for correction of the proliferative diabetic retinopathy and rubeosis iridis, which resolved with treatment. However, the intraocular pressure in the left eye could not be adequately controlled. Therefore, trabeculectomy with mitomycin C using limbal-based conjunctival flap was performed. Three hours after the surgery, the patient developed a large and diffuse filtering bleb, but no leakage occurred from the conjunctival scar. However, on the first postoperative day, leakage was noted and the conjunctiva was at the leakage point. The leakage resolved transiently, but recurred the next day. Severe keratoconjunctival epithelial failure was detected, and the patient was administrated 0.1% sodium hyaluronate eye drops six times daily. The epithelial failure improved, and many microcysts were detected on the bleb surface where the epithelial failure improved. The leakage resolved 2 days after initiation of the sodium hyaluronate eye drops. The microcysts disappeared and the bleb surface became smooth 1 month later.
Visual recovery from optic atrophy following acute optic neuropathy in the fellow eye.
Ornek, Kemal; Ornek, Nurgül
2012-06-01
The left eye of a 65-year-old male was blind due to optic atrophy and only seeing eye had also dry type age-related macular degeneration. An anterior ischemic optic neuropathy developed in the better seeing eye. Vision recovered in the blind eye in a short time after losing the better eye. Gaining some vision in a blind eye may be an adaptation of visual pathway in such patients.
Super-resolution optics for virtual reality
NASA Astrophysics Data System (ADS)
Grabovičkić, Dejan; Benitez, Pablo; Miñano, Juan C.; Zamora, Pablo; Buljan, Marina; Narasimhan, Bharathwaj; Nikolic, Milena I.; Lopez, Jesus; Gorospe, Jorge; Sanchez, Eduardo; Lastres, Carmen; Mohedano, Ruben
2017-06-01
In present commercial Virtual Reality (VR) headsets the resolution perceived is still limited, since the VR pixel density (typically 10-15 pixels/deg) is well below what the human eye can resolve (60 pixels/deg). We present here novel advanced optical design approaches that dramatically increase the perceived resolution of the VR keeping the large FoV required in VR applications. This approach can be applied to a vast number of optical architectures, including some advanced configurations, as multichannel designs. All this is done at the optical design stage, and no eye tracker is needed in the headset.
He, Miao; Ding, Hui; He, Hong; Zhang, Chi; Liu, Liangping; Zhong, Xingwu
2017-05-17
The aim of this study was to evaluate corneal biomechanical properties in a population of healthy children in China using corneal visualization Scheimpflug technology (CST). All children underwent complete bi-ocular examinations. CST provided intraocular pressure (IOP) and corneal biomechanical parameters, including time, velocity, length and deformation amplitude at first applanation (A1T, A1V, A1L, A1DA), at second applanation (A2T, A2V, A2L, A2DA), highest concavity time (HCT), maximum deformation amplitude (MDA), peak distance (PD), and radius of curvature (RoC). Pearson correlation analysis was used to assess the impacts of demographic factors, central corneal thickness (CCT), spherical equivalent (SE), and IOP on corneal biomechanics. One hundred eight subjects (32 girls and 76 boys) with the mean age of 10.80 ± 4.13 years (range 4 to18 years) were included in the final analyses. The right and left eyes were highly symmetrical in SE (p = 0.082), IOP (p = 0.235), or CCT (p = 0.210). Mean A1T of the right eyes was 7.424 ± 0.340 ms; the left eyes 7.451 ± 0.365 ms. MDA was 0.993 ± 0.102 mm in the right eyes and 0.982 ± 0.100 mm in the left eyes. Mean HCT of the right eyes was 16.675 ± 0.502 ms; the left eyes 16.735 ± 0.555 ms. All CST parameters of both eye were remarkably symmetrical with the exception of A2L (p = 0.006), A1DA (p = 0.025). The majority of CST parameters of both eyes were significantly correlated with CCT and IOP (p < 0.05). However, age, SE, and sex exert little influence on the CST measurements. This study found interocular symmetry in corneal biomechanics in healthy children eyes. Several CST biomechanical parameters in children are modified by CCT and IOP.
Kartı, Ömer; Zengin, Mehmet Özgür; Çelik, Ozan; Tokat, Taşkın; Küsbeci, Tuncay
2018-04-01
Olfactory neuroblastoma (ONB), which is a neuroectodermal tumor of the nasal cavity, is a rare and locally aggressive malignancy that may invade the orbit via local destruction. In this study, we report a patient with proptosis, external ophthalmoplegia, and compressive optic neuropathy caused by ONB. A detailed clinical examination including ocular imaging and histopathological studies were performed. The 62-year-old female patient presented to our clinic with complaints of proptosis and visual deterioration in the left eye. Her complaints started 2 months prior to admission. Visual acuity in the left eye was counting fingers from 2 meters. There was relative afferent pupillary defect. She had 6 mm of proptosis and limitation of motility. Fundus examination was normal in the right eye, but there was a hyperemic disc, and increased vascular tortuosity and dilation of the retinal veins in the left eye. Computerized tomography and magnetic resonance imaging of the brain and orbits demonstrated a large heterogeneous mass in the left superior nasal cavity with extensions into the ethmoidal sinuses as well as into the left orbit, compressing the medial rectus muscle and optic nerve. Endoscopic biopsy of the lesion was consistent with an ONB (Hyams' grade III). Orbital invasion may occur in patients with ONB. Therefore, it is important to be aware of this malignancy because some patients present with ophthalmic signs such as external ophthalmoplegia, proptosis, or compressive optic neuropathy.
View Ahead After Spirit's Sol 1861 Drive (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11977 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11977 NASA's Mars Exploration Rover Spirit used its navigation camera to take the images combined into this stereo, 210-degree view of the rover's surroundings during the 1,861st to 1,863rd Martian days, or sols, of Spirit's surface mission (March 28 to 30, 2009). This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The center of the scene is toward the south-southwest. East is on the left. West-northwest is on the right. The rover had driven 22.7 meters (74 feet) southwestward on Sol 1861 before beginning to take the frames in this view. The drive brought Spirit past the northwestern corner of Home Plate. In this view, the western edge of Home Plate is on the portion of the horizon farthest to the left. A mound in middle distance near the center of the view is called 'Tsiolkovsky' and is about 40 meters (about 130 feet) from the rover's position. This view is presented as a cylindrical-perspective projection with geometric seam correction.Chronic low-grade postoperative endophthalmitis in a child with Marfan syndrome
Khurram Butt, Darakhshanda; Scott, Robert A; Upendran, Muralidharan R
2017-01-01
This case report describes a 9-year-old male who presented to the emergency department with 2 days’ history of left painful red eye. On initial examination, his outside medical records indicated that he had bilateral subluxated lenses and had undergone left eye lensectomy with glued intrascleral fixation of an intraocular lens 8 weeks earlier. Vision in left eye was poor from first postoperative day but with no undue pain or redness, and poor vision was attributed to possible vitreous bleed. Subsequent postoperative course was uneventful. He was discharged from ophthalmic care on topical steroids and antibiotic drops, one week postsurgery. The eye was healing well until he developed pain, for which ophthalmic care was sought. He underwent anterior chamber tap with intravitreal injections. Aqueous samples were positive for Staphylococcus aureus DNA by polymerase chain reaction. Post vitrectomy and implant removal, his recovery was good and vision improved to 0.50 LogMar with aphakic correction. PMID:29180908
Goodarzi, Naser; Dabbaghi, Parviz; Valipour, Habib; Vafadari, Behnam
2015-04-01
Based on the previous studies, we know that the hemispheric lateralization defects, increase the probability of psychological disorders. We also know that dominant limb is controlled by dominant hemisphere and limb preference is used as an indicator for hemisphere dominance. In this study we attempted to explore the hemispheric dominance by the use of three limbs (hand, foot and eye). We performed this survey on two samples, psychiatric patients compared with normal population. For this purpose, knowing that the organ dominance is stabilized in adolescence, and age has no effect on the people above 15, we used 48 high school girls and 65 boys as the final samples of normal population. The patient group included 57 male and 26 female who were chronic psychiatric patients. The result shows that left-eye dominance is more in patients than the normal group (P=0.000) but the handedness and footedness differences are not significance. In psychotic, bipolar and depressive disorders, eye dominance had significant difference (P=0.018). But this is not true about hand and foot dominance. Our findings proved that generally in psychiatric patients, left-eye dominance is more common, left-eye dominance is also more in psychotic and depressive disorders. It is less common in bipolar disorders.
Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung; Lee, Seung-Hwan
2017-08-01
Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE's effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. © The Author (2017). Published by Oxford University Press.
Jung, Wookyoung; Kang, Joong-Gu; Jeon, Hyeonjin; Shim, Miseon; Sun Kim, Ji; Leem, Hyun-Sung
2017-01-01
Abstract Faces are processed best when they are presented in the left visual field (LVF), a phenomenon known as LVF superiority. Although one eye contributes more when perceiving faces, it is unclear how the dominant eye (DE), the eye we unconsciously use when performing a monocular task, affects face processing. Here, we examined the influence of the DE on the LVF superiority for faces using event-related potentials. Twenty left-eye-dominant (LDE group) and 23 right-eye-dominant (RDE group) participants performed the experiments. Face stimuli were randomly presented in the LVF or right visual field (RVF). The RDE group exhibited significantly larger N170 amplitudes compared with the LDE group. Faces presented in the LVF elicited N170 amplitudes that were significantly more negative in the RDE group than they were in the LDE group, whereas the amplitudes elicited by stimuli presented in the RVF were equivalent between the groups. The LVF superiority was maintained in the RDE group but not in the LDE group. Our results provide the first neural evidence of the DE’s effects on the LVF superiority for faces. We propose that the RDE may be more biologically specialized for face processing. PMID:28379584
Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P
2012-11-01
We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Development of an interactive anatomical three-dimensional eye model.
Allen, Lauren K; Bhattacharyya, Siddhartha; Wilson, Timothy D
2015-01-01
The discrete anatomy of the eye's intricate oculomotor system is conceptually difficult for novice students to grasp. This is problematic given that this group of muscles represents one of the most common sites of clinical intervention in the treatment of ocular motility disorders and other eye disorders. This project was designed to develop a digital, interactive, three-dimensional (3D) model of the muscles and cranial nerves of the oculomotor system. Development of the 3D model utilized data from the Visible Human Project (VHP) dataset that was refined using multiple forms of 3D software. The model was then paired with a virtual user interface in order to create a novel 3D learning tool for the human oculomotor system. Development of the virtual eye model was done while attempting to adhere to the principles of cognitive load theory (CLT) and the reduction of extraneous load in particular. The detailed approach, digital tools employed, and the CLT guidelines are described herein. © 2014 American Association of Anatomists.
Metastatic intraocular hemangiopericytoma in a dog
Pucket, Jonathan D.; Allbaugh, Rachel A.; Higginbotham, Mary L.; Rankin, Amy J.; Teixeira, Leandro
2017-01-01
A 10-year-old Labrador Retriever who had been undergoing therapy for a recurrent hemangiopericytoma of the right flank presented to the Kansas State University Ophthalmology service for evaluation of a painful left eye. Examination revealed secondary glaucoma and irreversible blindness of the affected eye and multifocal chorioretinal lesions in the fellow eye. Therapeutic and diagnostic enucleation of the left eye was performed and histopathologic examination demonstrated the presence of a presumed metastatic spindle cell sarcoma. Further immunohistochemical staining confirmed the intraocular neoplasia to be metastatic spread from the previously removed flank mass. Rapid progression in size and number of chorioretinal lesions in the right eye was noted in the post-operative period until the patient was euthanized one month after surgery. This case report is the first to document intraocular metastasis of hemangiopericytoma in a veterinary patient. PMID:28652979
Metastatic intraocular hemangiopericytoma in a dog.
Pucket, Jonathan D; Allbaugh, Rachel A; Higginbotham, Mary L; Rankin, Amy J; Teixeira, Leandro
2017-01-01
A 10-year-old Labrador Retriever who had been undergoing therapy for a recurrent hemangiopericytoma of the right flank presented to the Kansas State University Ophthalmology service for evaluation of a painful left eye. Examination revealed secondary glaucoma and irreversible blindness of the affected eye and multifocal chorioretinal lesions in the fellow eye. Therapeutic and diagnostic enucleation of the left eye was performed and histopathologic examination demonstrated the presence of a presumed metastatic spindle cell sarcoma. Further immunohistochemical staining confirmed the intraocular neoplasia to be metastatic spread from the previously removed flank mass. Rapid progression in size and number of chorioretinal lesions in the right eye was noted in the post-operative period until the patient was euthanized one month after surgery. This case report is the first to document intraocular metastasis of hemangiopericytoma in a veterinary patient.
76 FR 40445 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-08
...). Matthew K. Hagge Mr. Hagge, 31, has had optic atrophy in his right eye since 2007 due to multiple sclerosis. The visual acuity in his right eye is 20/250 and in his left eye, 20/20. Following an examination...
Alwadani, Fahad; Morsi, Mohammed Saad
2012-01-01
To compare the surgical proficiency of medical students who underwent traditional training or virtual reality training for argon laser trabeculoplasty with the PixEye simulator. The cohort comprised of 47 fifth year male medical students from the College of Medicine, King Faisal University, Saudi Arabia. The cohort was divided into two groups: students (n = 24), who received virtual reality training (VR Group) and students (n = 23), who underwent traditional training (Control Group). After training, the students performed the trabeculoplasty procedure. All trainings were included concurrent power point presentations describing the details of the procedure. Evaluation of surgical performance was based on the following variables: missing the exact location with the laser, overtreatment, undertreatment and inadvertent laser shots to iris and cornea. The target was missed by 8% of the VR Group compared to 55% in the Control Group. Overtreatment and undertreatment was observed in 7% of the VR Group compared to 46% of the Control Group. Inadvertent laser application to the cornea or iris was performed by 4.5% of the VR Group compared to 34% of the Control Group. Virtual reality training on PixEye simulator may enhance the proficiency of medical students and limit possible surgical errors during laser trabeculoplasty. The authors have no financial interest in the material mentioned in this study.
Optimizing virtual reality for all users through gaze-contingent and adaptive focus displays
Padmanaban, Nitish; Konrad, Robert; Stramer, Tal; Wetzstein, Gordon
2017-01-01
From the desktop to the laptop to the mobile device, personal computing platforms evolve over time. Moving forward, wearable computing is widely expected to be integral to consumer electronics and beyond. The primary interface between a wearable computer and a user is often a near-eye display. However, current generation near-eye displays suffer from multiple limitations: they are unable to provide fully natural visual cues and comfortable viewing experiences for all users. At their core, many of the issues with near-eye displays are caused by limitations in conventional optics. Current displays cannot reproduce the changes in focus that accompany natural vision, and they cannot support users with uncorrected refractive errors. With two prototype near-eye displays, we show how these issues can be overcome using display modes that adapt to the user via computational optics. By using focus-tunable lenses, mechanically actuated displays, and mobile gaze-tracking technology, these displays can be tailored to correct common refractive errors and provide natural focus cues by dynamically updating the system based on where a user looks in a virtual scene. Indeed, the opportunities afforded by recent advances in computational optics open up the possibility of creating a computing platform in which some users may experience better quality vision in the virtual world than in the real one. PMID:28193871
High correlation between performance on a virtual-reality simulator and real-life cataract surgery.
Thomsen, Ann Sofia Skou; Smith, Phillip; Subhi, Yousif; Cour, Morten la; Tang, Lilian; Saleh, George M; Konge, Lars
2017-05-01
To investigate the correlation in performance of cataract surgery between a virtual-reality simulator and real-life surgery using two objective assessment tools with evidence of validity. Cataract surgeons with varying levels of experience were included in the study. All participants performed and videorecorded three standard cataract surgeries before completing a proficiency-based test on the EyeSi virtual-reality simulator. Standard cataract surgeries were defined as: (1) surgery performed under local anaesthesia, (2) patient age >60 years, and (3) visual acuity >1/60 preoperatively. A motion-tracking score was calculated by multiplying average path length and average number of movements from the three real-life surgical videos of full procedures. The EyeSi test consisted of five abstract and two procedural modules: intracapsular navigation, antitremor training, intracapsular antitremor training, forceps training, bimanual training, capsulorhexis and phaco divide and conquer. Eleven surgeons were enrolled. After a designated warm-up period, the proficiency-based test on the EyeSi simulator was strongly correlated to real-life performance measured by motion-tracking software of cataract surgical videos with a Pearson correlation coefficient of -0.70 (p = 0.017). Performance on the EyeSi simulator is significantly and highly correlated to real-life surgical performance. However, it is recommended that performance assessments are made using multiple data sources. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
The biomechanical significance of pulley on binocular vision.
Guo, Hongmei; Gao, Zhipeng; Chen, Weiyi
2016-12-28
Pulleys have been reported as the functional origins of the rectus extraocular muscles (EOMs). However, biomechanical significance of pulleys on binocular vision has not been reported. Three eye movement models, i.e., non-pulley model, passive-pulley model, and active-pulley model, are used to simulate the horizontal movement of the eyes from the primary position to the left direction in the range of 1°-30°. The resultant forces of six EOMs along both orthogonal directions (i.e., the x-axis and y-axis defined in this paper) in the horizontal plane are calculated using the three models. The resultant force along the y-axis of the left eye for non-pulley model are significantly larger than that of the other two pulley models. The difference of the force, between the left eye and the right eye in non-pulley model, is larger than those in the other two pulley models along x-axis and y-axis. The pulley models present more biomechanical advantage on the horizontally binocular vision than the non-pulley model. Combining with the previous imaging evidences of pulleys, the results show that pulley model coincides well with the real physiological conditions.
Gender differences in cerebral metabolism for color processing in mice: A PET/MRI Study.
Njemanze, Philip C; Kranz, Mathias; Amend, Mario; Hauser, Jens; Wehrl, Hans; Brust, Peter
2017-01-01
Color processing is a central component of mammalian vision. Gender-related differences of color processing revealed by non-invasive functional transcranial Doppler ultrasound suggested right hemisphere pattern for blue/yellow chromatic opponency by men, and a left hemisphere pattern by women. The present study measured the accumulation of [18F]fluorodeoxyglucose ([18F]FDG) in mouse brain using small animal positron emission tomography and magnetic resonance imaging (PET/MRI) with statistical parametric mapping (SPM) during light stimulation with blue and yellow filters compared to darkness condition. PET revealed a reverse pattern relative to dark condition compared to previous human studies: Male mice presented with left visual cortex dominance for blue through the right eye, while female mice presented with right visual cortex dominance for blue through the left eye. We applied statistical parametric mapping (SPM) to examine gender differences in activated architectonic areas within the orbital and medial prefrontal cortex and related cortical and sub-cortical areas that lead to the striatum, medial thalamus and other brain areas. The metabolic connectivity of the orbital and medial prefrontal cortex evoked by blue stimulation spread through a wide range of brain structures implicated in viscerosensory and visceromotor systems in the left intra-hemispheric regions in male, but in the right-to-left inter-hemispheric regions in female mice. Color functional ocular dominance plasticity was noted in the right eye in male mice but in the left eye in female mice. This study of color processing in an animal model could be applied in the study of the role of gender differences in brain disease.
Comparing Interrater reliability between eye examination and eye self-examination 1
de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio
2017-01-01
Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269
Spontaneous closure of traumatic macular hole
Sanjay, Srinivasan; Yeo, Tun Kuan; Au Eong, Kah-Guan
2012-01-01
Macular hole formation is a well-known complication following ocular trauma. Less commonly recognised is the spontaneous closure of such holes. A 27-year-old man presented with a history of blunt trauma to his left eye. Eye evaluation showed conjunctival laceration, diffuse retinal oedema and multiple retinal haemorrhages in that eye. A month later, he developed a full thickness macular hole. Two months later, there was spontaneous complete closure of the full-thickness macular hole in the left eye as confirmed on optical coherence tomography. Spontaneous closure of hole is not uncommon. Observation for a period of up to 12 months is a reasonable management option. Macular hole surgery for traumatic macular holes may be delayed in such cases. PMID:23961017
Unilateral Macular Star in a Case of Hypertension and Retinitis Pigmentosa.
Chawla, Rohan; Tripathy, Koushik; Chaudhary, Sunil; Phuljhele, Swati; Venkatesh, Pradeep
2017-01-01
To describe a case of hypertension and retinitis pigmentosa presenting with a unilateral macular star. Case report. A 17-year-old female with chronic kidney disease and hypertension presented with a mild blurring of vision in the left eye. There was a history of night blindness. Both eyes had optic disc pallor, arteriolar attenuation, and peripheral bony spicules suggestive of the triad of retinitis pigmentosa. Macular star was seen in the left eye alone. We ascribe the macular star to hypertension as the patient had only a mild decrease in vision, no relative afferent pupillary defect, and similar visual evoked response amplitude and latency in both eyes. Unilateral macular star may be seen in hypertension and may simulate neuroretinitis in the clinical setting.
Yi, Li; Fan, Yuebo; Quinn, Paul C.; Feng, Cong; Huang, Dan; Li, Jiao; Mao, Guoquan; Lee, Kang
2012-01-01
There has been considerable controversy regarding whether children with autism spectrum disorder (ASD) and typically developing children (TD) show different eye movement patterns when processing faces. We investigated ASD and age- and IQ-matched TD children's scanning of faces using a novel multi-method approach. We found that ASD children spent less time looking at the whole face generally. After controlling for this difference, ASD children's fixations of the other face parts, except for the eye region, and their scanning paths between face parts were comparable either to the age-matched or IQ-matched TD groups. In contrast, in the eye region, ASD children's scanning differed significantly from that of both TD groups: (a) ASD children fixated significantly less on the right eye (from the observer's view); (b) ASD children's fixations were more biased towards the left eye region; and (c) ASD children fixated below the left eye, whereas TD children fixated on the pupil region of the eye. Thus, ASD children do not have a general abnormality in face scanning. Rather, their abnormality is limited to the eye region, likely due to their strong tendency to avoid eye contact. PMID:23929830
Primary orbital precursor T-cell lymphoblastic lymphoma: Report of a unique case
Stenman, Lisa; Persson, Marta; Enlund, Fredrik; Clasen-Linde, Erik; Stenman, Göran; Heegaard, Steffen
2016-01-01
Primary T-cell lymphoblastic lymphoma (T-LBL) in the eye region is very rare. The present study described a unique case of T-LBL involving the extraocular muscles. A 22-year-old male patient presented with a 3-week history of headache, reduced visual acuity and edema of the left eye. Clinical examination revealed left-sided exophthalmus, periorbital edema, chemosis, and reduced motility of the left eye. A magnetic resonance imaging scan revealed thickening of the left orbital muscles and a positron emission tomography-computed tomography scan also demonstrated activity in a subclavicular lymph node. Histopathological analysis of both lesions revealed infiltration by medium-sized neoplastic lymphoid cells with a high nuclear-cytoplasmic ratio and a high mitotic index. Immunostaining revealed positivity for CD2, CD3, CD99, Tia-1, and GranzymB, and variable positivity for CD4. There was no involvement of the bone marrow. Based on the clinical and histopathological findings, a diagnosis of T-LBL was made. There was no evidence of NOTCH1 mutation or rearrangements of the ETV6 and MLL genes and high-resolution array-based comparative genomic hybridization (arrayCGH) analysis revealed a normal genomic profile. The patient received chemotherapy according to the high-risk NOPHO protocol, followed by myeloablative allogenic bone marrow transplantation. At 35 months after diagnosis, the patient remained in complete first remission, but without light perception on his left eye. To the best of our knowledge, this is the first report of a case of T-LBL involving the extraocular muscles. Although primary T-LBL in the eye region is very rare, our findings demonstrate that lymphoma should be considered in the differential diagnosis of patients with similar symptoms. PMID:27900092
Mazerand, Edouard; Le Renard, Marc; Hue, Sophie; Lemée, Jean-Michel; Klinger, Evelyne; Menei, Philippe
2017-01-01
Brain mapping during awake craniotomy is a well-known technique to preserve neurological functions, especially the language. It is still challenging to map the optic radiations due to the difficulty to test the visual field intraoperatively. To assess the visual field during awake craniotomy, we developed the Functions' Explorer based on a virtual reality headset (FEX-VRH). The impaired visual field of 10 patients was tested with automated perimetry (the gold standard examination) and the FEX-VRH. The proof-of-concept test was done during the surgery performed on a patient who was blind in his right eye and presenting with a left parietotemporal glioblastoma. The FEX-VRH was used intraoperatively, simultaneously with direct subcortical electrostimulation, allowing identification and preservation of the optic radiations. The FEX-VRH detected 9 of the 10 visual field defects found by automated perimetry. The patient who underwent an awake craniotomy with intraoperative mapping of the optic tract using the FEX-VRH had no permanent postoperative visual field defect. Intraoperative visual field assessment with the FEX-VRH during direct subcortical electrostimulation is a promising approach to mapping the optical radiations and preventing a permanent visual field defect during awake surgery for epilepsy or tumor. Copyright © 2016 Elsevier Inc. All rights reserved.
Is LASIK for Me? A Patient's Guide to Refractive Surgery
... whether LASIK would be appropriate for you are: • dry eye syndrome . If dry eye is left untreated prior to surgery, patients may be disappointed with their LASIK results. If dry eye is diagnosed and adequately treated before surgery, you ...
Serchi, V; Peruzzi, A; Cereatti, A; Della Croce, U
2016-01-01
The knowledge of the visual strategies adopted while walking in cognitively engaging environments is extremely valuable. Analyzing gaze when a treadmill and a virtual reality environment are used as motor rehabilitation tools is therefore critical. Being completely unobtrusive, remote eye-trackers are the most appropriate way to measure the point of gaze. Still, the point of gaze measurements are affected by experimental conditions such as head range of motion and visual stimuli. This study assesses the usability limits and measurement reliability of a remote eye-tracker during treadmill walking while visual stimuli are projected. During treadmill walking, the head remained within the remote eye-tracker workspace. Generally, the quality of the point of gaze measurements declined as the distance from the remote eye-tracker increased and data loss occurred for large gaze angles. The stimulus location (a dot-target) did not influence the point of gaze accuracy, precision, and trackability during both standing and walking. Similar results were obtained when the dot-target was replaced by a static or moving 2D target and "region of interest" analysis was applied. These findings foster the feasibility of the use of a remote eye-tracker for the analysis of gaze during treadmill walking in virtual reality environments.
Analysis of EEG Related Saccadic Eye Movement
NASA Astrophysics Data System (ADS)
Funase, Arao; Kuno, Yoshiaki; Okuma, Shigeru; Yagi, Tohru
Our final goal is to establish the model for saccadic eye movement that connects the saccade and the electroencephalogram(EEG). As the first step toward this goal, we recorded and analyzed the saccade-related EEG. In the study recorded in this paper, we tried detecting a certain EEG that is peculiar to the eye movement. In these experiments, each subject was instructed to point their eyes toward visual targets (LEDs) or the direction of the sound sources (buzzers). In the control cases, the EEG was recorded in the case of no eye movemens. As results, in the visual experiments, we found that the potential of EEG changed sharply on the occipital lobe just before eye movement. Furthermore, in the case of the auditory experiments, similar results were observed. In the case of the visual experiments and auditory experiments without eye movement, we could not observed the EEG changed sharply. Moreover, when the subject moved his/her eyes toward a right-side target, a change in EEG potential was found on the right occipital lobe. On the contrary, when the subject moved his/her eyes toward a left-side target, a sharp change in EEG potential was found on the left occipital lobe.
Team Leader: Tom Peters--TAP Information Services
ERIC Educational Resources Information Center
Library Journal, 2005
2005-01-01
Tom Peters packs 36 hours of work into the confines of a 24-hour day. Without breaking a sweat, he juggles multiple collaborative projects, which currently include an Illinois academic library shared storage facility; a multistate virtual reference and instruction service for blind and visually impaired individuals (InfoEyes); a virtual meeting…
Application of Virtual Reality Technology in Biology Education.
ERIC Educational Resources Information Center
Shim, Kew-Cheol; Park, Jong-Seok; Kim, Hyun-Sup; Kim, Jae-Hyun; Park, Young-Chul; Ryu, Hai-Il
2003-01-01
Reports on the findings of a study designed to develop three-dimensional virtual reality technology (VRT) learning programs for middle school students and evaluate the program's educational value. Focuses on the topic of structure and function of the eye. Concludes that VRT simulations allow comfortable interaction with computers and increase the…
Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa
2013-07-01
The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.
Weiss, Jeffrey N; Levy, Steven; Benes, Susan C
2015-09-01
We present the results from a patient with relapsing optic neuropathy treated within the Stem Cell Ophthalmology Treatment Study (SCOTS). SCOTS is an Institutional Review Board approved clinical trial and has become the largest ophthalmology stem cell study registered at the National Institutes of Health to date (www.clinicaltrials.gov Identifier NCT 01920867). SCOTS utilizes autologous bone marrow-derived stem cells (BMSCs) for treatment of retinal and optic nerve diseases. Pre-treatment and post-treatment comprehensive eye exams of a 54 year old female patient were performed both at the Florida Study Center, USA and at The Eye Center of Columbus, USA. As a consequence of a relapsing optic neuritis, the patient's previously normal visual acuity decreased to between 20/350 and 20/400 in the right eye and to 20/70 in the left eye. Significant visual field loss developed bilaterally. The patient underwent a right eye vitrectomy with injection of BMSCs into the optic nerve of the right eyeand retrobulbar, subtenon and intravitreal injection of BMSCs in the left eye. At 15 months after SCOTS treatment, the patient's visual acuity had improved to 20/150 in the right eye and 20/20 in the left eye. Bilateral visual fields improved markedly. Both macular thickness and fast retinal nerve fiber layer thickness were maximally improved at 3 and 6 months after SCOTS treatment. The patient also reduced her mycophenylate dose from 1,500 mg per day to 500 mg per day and required no steroid pulse therapy during the 15-month follow up.
Teufel, Julian; Bardins, S; Spiegel, Rainer; Kremmyda, O; Schneider, E; Strupp, M; Kalla, R
2016-01-04
Patients with downbeat nystagmus syndrome suffer from oscillopsia, which leads to an unstable visual perception and therefore impaired visual acuity. The aim of this study was to use real-time computer-based visual feedback to compensate for the destabilizing slow phase eye movements. The patients were sitting in front of a computer screen with the head fixed on a chin rest. The eye movements were recorded by an eye tracking system (EyeSeeCam®). We tested the visual acuity with a fixed Landolt C (static) and during real-time feedback driven condition (dynamic) in gaze straight ahead and (20°) sideward gaze. In the dynamic condition, the Landolt C moved according to the slow phase eye velocity of the downbeat nystagmus. The Shapiro-Wilk test was used to test for normal distribution and one-way ANOVA for comparison. Ten patients with downbeat nystagmus were included in the study. Median age was 76 years and the median duration of symptoms was 6.3 years (SD +/- 3.1y). The mean slow phase velocity was moderate during gaze straight ahead (1.44°/s, SD +/- 1.18°/s) and increased significantly in sideward gaze (mean left 3.36°/s; right 3.58°/s). In gaze straight ahead, we found no difference between the static and feedback driven condition. In sideward gaze, visual acuity improved in five out of ten subjects during the feedback-driven condition (p = 0.043). This study provides proof of concept that non-invasive real-time computer-based visual feedback compensates for the SPV in DBN. Therefore, real-time visual feedback may be a promising aid for patients suffering from oscillopsia and impaired text reading on screen. Recent technological advances in the area of virtual reality displays might soon render this approach feasible in fully mobile settings.
Ishii, Youhei; Morita, Kiichiro; Shouji, Yoshihisa; Nakashima, Youko; Uchimura, Naohisa
2010-02-01
Emotion-associated sounds have been suggested to exert important effects upon human personal relationships. The present study was aimed to characterize the effects of the sounds of crying or laughing on visual cognitive function in schizophrenia patients. We recorded exploratory eye movements in 24 schizophrenia patients (mean age, 27.0 +/- 6.1 years; 14 male, 10 female) and age-matched controls. The total eye scanning length (TESL) and total number of gaze points in the left (left TNGP) and right (right TNGP) visual fields of the screen and the number of researching areas (NRA) were determined using eye-mark recording in the presence/absence of emotionally charged sounds. Controls' TESL for smiling pictures was longer than that for crying pictures irrespective of sounds. Patients' TESL for smiling pictures, however, was shorter than for crying pictures irrespective of the sounds. The left TNGP for smiling pictures was lower in patients than controls independent of sound. Importantly, the right TNGP was significantly larger with laughing sounds than in the absence of sound. In controls, the NRA for smiling pictures was significantly greater than for crying pictures irrespective of sound. Patient NRA did not significantly differ between smiling and crying pictures irrespective of sound. Eye movements in schizophrenia patients' left field for smiling pictures associated with laughing sounds particularly differed from those in controls, suggesting impaired visual cognitive function associated with positive emotion, also involving pleasure-related sounds, in schizophrenia.
77 FR 60008 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... in a CMV. Terry J. Edwards Mr. Edwards, 53, has a prosthetic right eye due to a traumatic injury... left eye due to a traumatic injury sustained at age 2. The best corrected visual acuity in his right... his right eye due to a traumatic injury sustained 10 years ago. The visual acuity in his right eye is...
2010-01-01
Background European robins, Erithacus rubecula, show two types of directional responses to the magnetic field: (1) compass orientation that is based on radical pair processes and lateralized in favor of the right eye and (2) so-called 'fixed direction' responses that originate in the magnetite-based receptors in the upper beak. Both responses are light-dependent. Lateralization of the 'fixed direction' responses would suggest an interaction between the two magnetoreception systems. Results Robins were tested with either the right or the left eye covered or with both eyes uncovered for their orientation under different light conditions. With 502 nm turquoise light, the birds showed normal compass orientation, whereas they displayed an easterly 'fixed direction' response under a combination of 502 nm turquoise with 590 nm yellow light. Monocularly right-eyed birds with their left eye covered were oriented just as they were binocularly as controls: under turquoise in their northerly migratory direction, under turquoise-and-yellow towards east. The response of monocularly left-eyed birds differed: under turquoise light, they were disoriented, reflecting a lateralization of the magnetic compass system in favor of the right eye, whereas they continued to head eastward under turquoise-and-yellow light. Conclusion 'Fixed direction' responses are not lateralized. Hence the interactions between the magnetite-receptors in the beak and the visual system do not seem to involve the magnetoreception system based on radical pair processes, but rather other, non-lateralized components of the visual system. PMID:20707905
Hemifield columns co-opt ocular dominance column structure in human achiasma.
Olman, Cheryl A; Bao, Pinglei; Engel, Stephen A; Grant, Andrea N; Purington, Chris; Qiu, Cheng; Schallmo, Michael-Paul; Tjan, Bosco S
2018-01-01
In the absence of an optic chiasm, visual input to the right eye is represented in primary visual cortex (V1) in the right hemisphere, while visual input to the left eye activates V1 in the left hemisphere. Retinotopic mapping In V1 reveals that in each hemisphere left and right visual hemifield representations are overlaid (Hoffmann et al., 2012). To explain how overlapping hemifield representations in V1 do not impair vision, we tested the hypothesis that visual projections from nasal and temporal retina create interdigitated left and right visual hemifield representations in V1, similar to the ocular dominance columns observed in neurotypical subjects (Victor et al., 2000). We used high-resolution fMRI at 7T to measure the spatial distribution of responses to left- and right-hemifield stimulation in one achiasmic subject. T 2 -weighted 2D Spin Echo images were acquired at 0.8mm isotropic resolution. The left eye was occluded. To the right eye, a presentation of flickering checkerboards alternated between the left and right visual fields in a blocked stimulus design. The participant performed a demanding orientation-discrimination task at fixation. A general linear model was used to estimate the preference of voxels in V1 to left- and right-hemifield stimulation. The spatial distribution of voxels with significant preference for each hemifield showed interdigitated clusters which densely packed V1 in the right hemisphere. The spatial distribution of hemifield-preference voxels in the achiasmic subject was stable between two days of testing and comparable in scale to that of human ocular dominance columns. These results are the first in vivo evidence showing that visual hemifield representations interdigitate in achiasmic V1 following a similar developmental course to that of ocular dominance columns in V1 with intact optic chiasm. Copyright © 2017 Elsevier Inc. All rights reserved.
Sex differences in a virtual water maze: an eye tracking and pupillometry study.
Mueller, Sven C; Jackson, Carl P T; Skelton, Ron W
2008-11-21
Sex differences in human spatial navigation are well known. However, the exact strategies that males and females employ in order to navigate successfully around the environment are unclear. While some researchers propose that males prefer environment-centred (allocentric) and females prefer self-centred (egocentric) navigation, these findings have proved difficult to replicate. In the present study we examined eye movements and physiological measures of memory (pupillometry) in order to compare visual scanning of spatial orientation using a human virtual analogue of the Morris Water Maze task. Twelve women and twelve men (average age=24 years) were trained on a visible platform and had to locate an invisible platform over a series of trials. On all but the first trial, participants' eye movements were recorded for 3s and they were asked to orient themselves in the environment. While the behavioural data replicated previous findings of improved spatial performance for males relative to females, distinct sex differences in eye movements were found. Males tended to explore consistently more space early on while females demonstrated initially longer fixation durations and increases in pupil diameter usually associated with memory processing. The eye movement data provides novel insight into differences in navigational strategies between the sexes.
[Followup of chicken pox keratitis. Anatomic-clinical case report].
D'hermies, F; Ellies, P; Meyer, A; Halhal, M; Morel, X; Behar-Cohen, F; Renard, G; Dighiero, P
2002-09-01
Chicken pox is a very common infectious disease in children. Its corneal involvement is less serious than with measles, which may lead to blindness in numerous developing countries. However, with occasional cases occur. A case of a 59-year-old male patient whose left cornea was involved during a chicken pox infection at the age of 7 is reported. More recently, the vision of the right eye was normal at 20/20 and reduced to visual perception in the affected left eye. Corneal sensitivity was maintained in the left eye, which, however exhibited a central epithelial defect. A central round opacity of the left corneal stroma was believed to be the scar resulting from a previous disciform keratitis. The left central cornea was thinned and there was neither an anterior chamber flare nor new corneal vessels. This corneal condition required a corneal allograft, performed quickly because of the potential risk of perforation. Histopathological study of the corneal button showed a central corneal thinning with an increase in epithelial thickness. The corneal stroma was disorganized, with irregular collagen bundles. No inflammatory cells could be observed, however. All the histopathological changes observed were those of a corneal scar.
Atypical cytomegalovirus retinitis in non-Hodgkin's lymphoma.
Tyagi, Mudit; Ambiya, Vikas; Mathai, Annie; Narayanan, Raja
2015-08-03
A 54-year-old woman, a known case of non-Hodgkin's lymphoma (NHL) in complete remission, presented with floaters and diminution of vision in her left eye. The eye had vitritis with non-haemorrhagic retinitis mimicking intraocular lymphoma and acute retinal necrosis. A vitreous sample was positive for cytomegalovirus (CMV) and herpes simplex virus 1 (HSV-1) DNA by PCR. The possibility of intraocular lymphoma was not confirmed by the immunohistochemistry of the vitreous sample. The patient had a relapse of NHL along with rapid deterioration of vision in her left eye to no perception of light, due to optic nerve involvement. The right eye developed a new patch of focal haemorrhagic retinitis threatening the fovea. Based on the laboratory results and the clinical findings, she was successfully managed as a case of bilateral CMV retinitis and the vision in her right eye was salvaged. 2015 BMJ Publishing Group Ltd.
Interocular high-order corneal wavefront aberration symmetry
NASA Astrophysics Data System (ADS)
Lombardo, Marco; Lombardo, Giuseppe; Serrao, Sebastiano
2006-04-01
The interocular symmetry of the high-order corneal wavefront aberration (WA) in a population of myopic eyes was analyzed before and after photorefractive keratectomy (PRK). The preoperative and one-year postoperative corneal aberration data (from third to seventh Zernike orders) for 4- and 7-mm pupils from right and left eyes were averaged after correcting for the effects of enantiomorphism to test for mirror symmetry. Also, the mean corneal point-spread function (PSF) for right and left eyes was calculated. Preoperatively, a moderate and high degree of correlation in the high-order corneal WA between eyes was found for 4- and 7-mm pupils, respectively. Myopic PRK did not significantly change the interocular symmetry of corneal high-order aberrations. No discernible differences in the orientation PSF between eyes were observed one year after surgery in comparison with the preoperative state over the two analyzed pupils.
Triscari, Maria Teresa; Faraci, Palmira; Catalisano, Dario; D'Angelo, Valerio; Urso, Viviana
2015-01-01
The purpose of the research was to compare the effectiveness of the following treatment methods for fear of flying: cognitive behavioral therapy (CBT) integrated with systematic desensitization, CBT combined with eye movement desensitization and reprocessing therapy, and CBT combined with virtual reality exposure therapy. Overall, our findings have proven the efficacy of all interventions in reducing fear of flying in a pre- to post-treatment comparison. All groups showed a decrease in flight anxiety, suggesting the efficiency of all three treatments in reducing self-report measures of fear of flying. In particular, our results indicated significant improvements for the treated patients using all the treatment programs, as shown not only by test scores but also by participation in the post-treatment flight. Nevertheless, outcome measures maintained a significant effect at a 1-year follow-up. In conclusion, combining CBT with both the application of eye movement desensitization and reprocessing treatment and the virtual stimuli used to expose patients with aerophobia seemed as efficient as traditional cognitive behavioral treatments integrated with systematic desensitization.
Simulating hemispatial neglect with virtual reality.
Baheux, Kenji; Yoshizawa, Makoto; Yoshida, Yasuko
2007-07-19
Hemispatial neglect is a cognitive disorder defined as a lack of attention for stimuli contra-lateral to the brain lesion. The assessment is traditionally done with basic pencil and paper tests and the rehabilitation programs are generally not well adapted. We propose a virtual reality system featuring an eye-tracking device for a better characterization of the neglect that will lead to new rehabilitation techniques. This paper presents a comparison of eye-gaze patterns of healthy subjects, patients and healthy simulated patients on a virtual line bisection test. The task was also executed with a reduced visual field condition hoping that fewer stimuli would limit the neglect. We found that patients and healthy simulated patients had similar eye-gaze patterns. However, while the reduced visual field condition had no effect on the healthy simulated patients, it actually had a negative impact on the patients. We discuss the reasons for these differences and how they relate to the limitations of the neglect simulation. We argue that with some improvements the technique could be used to determine the potential of new rehabilitation techniques and also help the rehabilitation staff or the patient's relatives to better understand the neglect condition.
Triscari, Maria Teresa; Faraci, Palmira; Catalisano, Dario; D’Angelo, Valerio; Urso, Viviana
2015-01-01
The purpose of the research was to compare the effectiveness of the following treatment methods for fear of flying: cognitive behavioral therapy (CBT) integrated with systematic desensitization, CBT combined with eye movement desensitization and reprocessing therapy, and CBT combined with virtual reality exposure therapy. Overall, our findings have proven the efficacy of all interventions in reducing fear of flying in a pre- to post-treatment comparison. All groups showed a decrease in flight anxiety, suggesting the efficiency of all three treatments in reducing self-report measures of fear of flying. In particular, our results indicated significant improvements for the treated patients using all the treatment programs, as shown not only by test scores but also by participation in the post-treatment flight. Nevertheless, outcome measures maintained a significant effect at a 1-year follow-up. In conclusion, combining CBT with both the application of eye movement desensitization and reprocessing treatment and the virtual stimuli used to expose patients with aerophobia seemed as efficient as traditional cognitive behavioral treatments integrated with systematic desensitization. PMID:26504391
Ocular effects of virtual reality headset wear in young adults.
Turnbull, Philip R K; Phillips, John R
2017-11-23
Virtual Reality (VR) headsets create immersion by displaying images on screens placed very close to the eyes, which are viewed through high powered lenses. Here we investigate whether this viewing arrangement alters the binocular status of the eyes, and whether it is likely to provide a stimulus for myopia development. We compared binocular status after 40-minute trials in indoor and outdoor environments, in both real and virtual worlds. We also measured the change in thickness of the ocular choroid, to assess the likely presence of signals for ocular growth and myopia development. We found that changes in binocular posture at distance and near, gaze stability, amplitude of accommodation and stereopsis were not different after exposure to each of the 4 environments. Thus, we found no evidence that the VR optical arrangement had an adverse effect on the binocular status of the eyes in the short term. Choroidal thickness did not change after either real world trial, but there was a significant thickening (≈10 microns) after each VR trial (p < 0.001). The choroidal thickening which we observed suggest that a VR headset may not be a myopiagenic stimulus, despite the very close viewing distances involved.
Goodarzi, Naser; Dabbaghi, Parviz; Valipour, Habib; Vafadari, Behnam
2015-01-01
Introduction: Based on the previous studies, we know that the hemispheric lateralization defects, increase the probability of psychological disorders. We also know that dominant limb is controlled by dominant hemisphere and limb preference is used as an indicator for hemisphere dominance. In this study we attempted to explore the hemispheric dominance by the use of three limbs (hand, foot and eye). Methods: We performed this survey on two samples, psychiatric patients compared with normal population. For this purpose, knowing that the organ dominance is stabilized in adolescence, and age has no effect on the people above 15, we used 48 high school girls and 65 boys as the final samples of normal population. The patient group included 57 male and 26 female who were chronic psychiatric patients. Results: The result shows that left-eye dominance is more in patients than the normal group (P=0.000) but the handedness and footedness differences are not significance. In psychotic, bipolar and depressive disorders, eye dominance had significant difference (P=0.018). But this is not true about hand and foot dominance. Discussion: Our findings proved that generally in psychiatric patients, left-eye dominance is more common, left-eye dominance is also more in psychotic and depressive disorders. It is less common in bipolar disorders. PMID:27307954
Molecular Diagnosis of an Ocular Toxocariasis Patient in Vietnam
Trung, Nguyen Vu; Duyet, Le Van; Chai, Jong-Yil
2013-01-01
An ocular Toxocara canis infection is reported for the first time in Vietnam. A 34-year-old man residing in a village of Son La Province, North Vietnam, visited the National Eye Hospital (NEH) in August 2011. He felt a bulge-sticking pain in his left eye and loss of vision occurred over 3 months before visiting the hospital. The eye examination in the hospital showed damage of the left eye, red eye, retinal fibrosis, retinal detachment, inflammation of the eye tissues, retinal granulomas, and a parasitic cyst inside. A larva of Toxocara was collected with the cyst by a medical doctor by surgery. Comparison of 264 nucleotides of internal transcribed spacer 2 (ITS2) of ribosomal DNA was done between our Vietnamese Toxocara canis and other Toxocara geographical isolates, including Chinese T. canis, Japanese T. canis, Sri Lankan T. canis, and Iranian T. canis. The nucleotide homology was 97-99%, when our T. canis was compared with geographical isolates. Identification of a T. canis infection in the eye by a molecular method was performed for the first time in Vietnam. PMID:24327783
Molecular diagnosis of an ocular toxocariasis patient in Vietnam.
Van De, Nguyen; Trung, Nguyen Vu; Duyet, Le Van; Chai, Jong-Yil
2013-10-01
An ocular Toxocara canis infection is reported for the first time in Vietnam. A 34-year-old man residing in a village of Son La Province, North Vietnam, visited the National Eye Hospital (NEH) in August 2011. He felt a bulge-sticking pain in his left eye and loss of vision occurred over 3 months before visiting the hospital. The eye examination in the hospital showed damage of the left eye, red eye, retinal fibrosis, retinal detachment, inflammation of the eye tissues, retinal granulomas, and a parasitic cyst inside. A larva of Toxocara was collected with the cyst by a medical doctor by surgery. Comparison of 264 nucleotides of internal transcribed spacer 2 (ITS2) of ribosomal DNA was done between our Vietnamese Toxocara canis and other Toxocara geographical isolates, including Chinese T. canis, Japanese T. canis, Sri Lankan T. canis, and Iranian T. canis. The nucleotide homology was 97-99%, when our T. canis was compared with geographical isolates. Identification of a T. canis infection in the eye by a molecular method was performed for the first time in Vietnam.
Bilateral fungal keratitis with ring infiltrates: a rare scenario.
Chaniyara, Manthan Hasmukhbhai; Pujari, Amar; Urkude, Jayanand; Sharma, Namrata
2017-10-09
A 12-year-old boy presented to the emergency department with chief complaints of pain, redness, discharge and diminution of vision in both eyes over the previous 20 days. There was no history of preceding trauma, contact lens use, any eye drop usage or ocular surgery. Systemic history was not significant. Presenting uncorrected visual acuity in his right eye was counting fingers at 1 m and 20/200 in the left eye, with accurate projection of rays in both eyes. Slit lamp biomicroscopy showed the presence of bilateral diffuse conjunctival congestion, corneal ring infiltrates and epithelial defect with corneal oedema. Potassium hydroxide wet mount showed the presence of septate fungal hyphae. The patient was treated with topical 5% natamycin and 1% voriconazole over a period of 6 weeks. Best-corrected visual acuity was 20/600 in the right eye and 20/20 in the left eye at 6-month follow-up. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Prototyping a Hybrid Cooperative and Tele-robotic Surgical System for Retinal Microsurgery.
Balicki, Marcin; Xia, Tian; Jung, Min Yang; Deguet, Anton; Vagvolgyi, Balazs; Kazanzides, Peter; Taylor, Russell
2011-06-01
This paper presents the design of a tele-robotic microsurgical platform designed for development of cooperative and tele-operative control schemes, sensor based smart instruments, user interfaces and new surgical techniques with eye surgery as the driving application. The system is built using the distributed component-based cisst libraries and the Surgical Assistant Workstation framework. It includes a cooperatively controlled EyeRobot2, a da Vinci Master manipulator, and a remote stereo visualization system. We use constrained optimization based virtual fixture control to provide Virtual Remote-Center-of-Motion (vRCM) and haptic feedback. Such system can be used in a hybrid setup, combining local cooperative control with remote tele-operation, where an experienced surgeon can provide hand-over-hand tutoring to a novice user. In another scheme, the system can provide haptic feedback based on virtual fixtures constructed from real-time force and proximity sensor information.
Prototyping a Hybrid Cooperative and Tele-robotic Surgical System for Retinal Microsurgery
Balicki, Marcin; Xia, Tian; Jung, Min Yang; Deguet, Anton; Vagvolgyi, Balazs; Kazanzides, Peter; Taylor, Russell
2013-01-01
This paper presents the design of a tele-robotic microsurgical platform designed for development of cooperative and tele-operative control schemes, sensor based smart instruments, user interfaces and new surgical techniques with eye surgery as the driving application. The system is built using the distributed component-based cisst libraries and the Surgical Assistant Workstation framework. It includes a cooperatively controlled EyeRobot2, a da Vinci Master manipulator, and a remote stereo visualization system. We use constrained optimization based virtual fixture control to provide Virtual Remote-Center-of-Motion (vRCM) and haptic feedback. Such system can be used in a hybrid setup, combining local cooperative control with remote tele-operation, where an experienced surgeon can provide hand-over-hand tutoring to a novice user. In another scheme, the system can provide haptic feedback based on virtual fixtures constructed from real-time force and proximity sensor information. PMID:24398557
Virtual reality and interactive 3D as effective tools for medical training.
Webb, George; Norcliffe, Alex; Cannings, Peter; Sharkey, Paul; Roberts, Dave
2003-01-01
CAVE-like displays allow a user to walk in to a virtual environment, and use natural movement to change the viewpoint of virtual objects which they can manipulate with a hand held device. This maps well to many surgical procedures offering strong potential for training and planning. These devices may be networked together allowing geographically remote users to share the interactive experience. This maps to the strong need for distance training and planning of surgeons. Our paper shows how the properties of a CAVE-Like facility can be maximised in order to provide an ideal environment for medical training. The implementation of a large 3D-eye is described. The resulting application is that of an eye that can be manipulated and examined by trainee medics under the guidance of a medical expert. The progression and effects of different ailments can be illustrated and corrective procedures, demonstrated.
Periocular necrotizing fasciitis in an infant.
Proia, Alan D
Periocular necrotizing fasciitis developed in a 12-month-old boy with swelling of both eyes and redness and a discharge from the left eye approximately 36 hours after blunt trauma. Computed tomography revealed preseptal and soft-tissue edema on the left side, but no signs of orbital involvement, orbital fractures, or drainable abscess in the anterior left lower eyelid. The inflammatory signs worsened over the next day, and there was purulent discharge from the left lower eyelid and an abscess and necrosis of the lower eyelid skin. He did well following surgical debridement and treatment with intravenous antibiotics. His course highlights the difficulty in diagnosing necrotizing fasciitis and the necessity for prompt surgical debridement and empirical broad-spectrum antibiotic therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Practical low-cost stereo head-mounted display
NASA Astrophysics Data System (ADS)
Pausch, Randy; Dwivedi, Pramod; Long, Allan C., Jr.
1991-08-01
A high-resolution head-mounted display has been developed from substantially cheaper components than previous systems. Monochrome displays provide 720 by 280 monochrome pixels to each eye in a one-inch-square region positioned approximately one inch from each eye. The display hardware is the Private Eye, manufactured by Reflection Technologies, Inc. The tracking system uses the Polhemus Isotrak, providing (x,y,z, azimuth, elevation and roll) information on the user''s head position and orientation 60 times per second. In combination with a modified Nintendo Power Glove, this system provides a full-functionality virtual reality/simulation system. Using two host 80386 computers, real-time wire frame images can be produced. Other virtual reality systems require roughly 250,000 in hardware, while this one requires only 5,000. Stereo is particularly useful for this system because shading or occlusion cannot be used as depth cues.
NASA Astrophysics Data System (ADS)
Ciunel, St.; Tica, B.
2016-08-01
The paper presents the studies made on a similar biomechanical system composed by neck, head and thorax bones. The models were defined in a CAD environment which includes Adams algorithm for dynamic simulations. The virtual models and the entire morphology were obtained starting with CT images made on a living human subject. The main movements analyzed were: axial rotation (left-right), lateral bending (left-right) and flexion- extension movement. After simulation was obtained the entire biomechanical behavior based on data tables or diagrams. That virtual model composed by neck and head can be included in complex system (as a car system) and supposed to several impact simulations (virtual crash tests). Also, our research team built main components of a testing device for dummy car crash neck-head system using anatomical data.
Lustig, Avichai; Ketter-Katz, Hadas; Katzir, Gadi
2013-01-01
Lateralization is mostly analyzed for single traits, but seldom for two or more traits while performing a given task (e.g. object manipulation). We examined lateralization in eye use and in body motion that co-occur during avoidance behaviour of the common chameleon, Chamaeleo chameleon. A chameleon facing a moving threat smoothly repositions its body on the side of its perch distal to the threat, to minimize its visual exposure. We previously demonstrated that during the response (i) eye use and body motion were, each, lateralized at the tested group level (N = 26), (ii) in body motion, we observed two similar-sized sub-groups, one exhibiting a greater reduction in body exposure to threat approaching from the left and one – to threat approaching from the right (left- and right-biased subgroups), (iii) the left-biased sub-group exhibited weak lateralization of body exposure under binocular threat viewing and none under monocular viewing while the right-biased sub-group exhibited strong lateralization under both monocular and binocular threat viewing. In avoidance, how is eye use related to body motion at the entire group and at the sub-group levels? We demonstrate that (i) in the left-biased sub-group, eye use is not lateralized, (ii) in the right-biased sub-group, eye use is lateralized under binocular, but not monocular viewing of the threat, (iii) the dominance of the right-biased sub-group determines the lateralization of the entire group tested. We conclude that in chameleons, patterns of lateralization of visual function and body motion are inter-related at a subtle level. Presently, the patterns cannot be compared with humans' or related to the unique visual system of chameleons, with highly independent eye movements, complete optic nerve decussation and relatively few inter-hemispheric commissures. We present a model to explain the possible inter-hemispheric differences in dominance in chameleons' visual control of body motion during avoidance. PMID:23967099
Lustig, Avichai; Ketter-Katz, Hadas; Katzir, Gadi
2013-01-01
Lateralization is mostly analyzed for single traits, but seldom for two or more traits while performing a given task (e.g. object manipulation). We examined lateralization in eye use and in body motion that co-occur during avoidance behaviour of the common chameleon, Chamaeleo chameleon. A chameleon facing a moving threat smoothly repositions its body on the side of its perch distal to the threat, to minimize its visual exposure. We previously demonstrated that during the response (i) eye use and body motion were, each, lateralized at the tested group level (N = 26), (ii) in body motion, we observed two similar-sized sub-groups, one exhibiting a greater reduction in body exposure to threat approaching from the left and one--to threat approaching from the right (left- and right-biased subgroups), (iii) the left-biased sub-group exhibited weak lateralization of body exposure under binocular threat viewing and none under monocular viewing while the right-biased sub-group exhibited strong lateralization under both monocular and binocular threat viewing. In avoidance, how is eye use related to body motion at the entire group and at the sub-group levels? We demonstrate that (i) in the left-biased sub-group, eye use is not lateralized, (ii) in the right-biased sub-group, eye use is lateralized under binocular, but not monocular viewing of the threat, (iii) the dominance of the right-biased sub-group determines the lateralization of the entire group tested. We conclude that in chameleons, patterns of lateralization of visual function and body motion are inter-related at a subtle level. Presently, the patterns cannot be compared with humans' or related to the unique visual system of chameleons, with highly independent eye movements, complete optic nerve decussation and relatively few inter-hemispheric commissures. We present a model to explain the possible inter-hemispheric differences in dominance in chameleons' visual control of body motion during avoidance.
Newman, David G
2002-11-01
This report describes a case of central serous retinopathy (CSR) in the right eye of a commercial air transport pilot which resulted in a permanent reduction in visual acuity and the loss of his license. The previously fit and well pilot developed sudden loss of central vision, which resolved spontaneously. He then went on to experience recurrent episodes of fluctuating visual acuity (down to 6/60) and visual dysfunction in the right eye. His left eye remained unaffected. Eventually his condition stabilized, and he was left with a permanent reduction in right visual acuity (6/36) with intact peripheral visual fields and a completely normal left eye. After a period of grounding of 12 mo, he sought to have his license reinstated. He was considered to be a functionally monocular pilot, and as such was granted a conditional Class 1 medical category. The aeromedical disposition of this pilot and the issues involved in determining the fitness to fly of pilots with permanent visual defects arising from CSR are discussed.
Spirit Beside 'Home Plate,' Sol 1809 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11803 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11803 NASA Mars Exploration Rover Spirit used its navigation camera to take the images assembled into this stereo, 120-degree view southward after a short drive during the 1,809th Martian day, or sol, of Spirit's mission on the surface of Mars (February 3, 2009). By combining images from the left-eye and right-eye sides of the navigation camera, the view appears three-dimensional when viewed through red-blue glasses with the red lens on the left. Spirit had driven about 2.6 meters (8.5 feet) that sol, continuing a clockwise route around a low plateau called 'Home Plate.' In this image, the rocks visible above the rovers' solar panels are on the slope at the northern edge of Home Plate. This view is presented as a cylindrical-perspective projection with geometric seam correction.Opportunity's Surroundings on Sol 1818 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11846 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11846 NASA's Mars Exploration Rover Opportunity used its navigation camera to take the images combined into this full-circle view of the rover's surroundings during the 1,818th Martian day, or sol, of Opportunity's surface mission (March 5, 2009). South is at the center; north at both ends. This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 80.3 meters (263 feet) southward earlier on that sol. Tracks from the drive recede northward in this view. The terrain in this portion of Mars' Meridiani Planum region includes dark-toned sand ripples and lighter-toned bedrock. This view is presented as a cylindrical-perspective projection with geometric seam correction.Opportunity's Surroundings on Sol 1798 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11850 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11850 NASA's Mars Exploration Rover Opportunity used its navigation camera to take the images combined into this stereo 180-degree view of the rover's surroundings during the 1,798th Martian day, or sol, of Opportunity's surface mission (Feb. 13, 2009). North is on top. This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 111 meters (364 feet) southward on the preceding sol. Tracks from that drive recede northward in this view. For scale, the distance between the parallel wheel tracks is about 1 meter (about 40 inches). The terrain in this portion of Mars' Meridiani Planum region includes dark-toned sand ripples and lighter-toned bedrock. This view is presented as a cylindrical-perspective projection with geometric seam correction.Cerebral venous hypertension and blindness: a reversible complication.
Cuadra, Salvador A; Padberg, Frank T; Turbin, Roger E; Farkas, Jeffrey; Frohman, Larry P
2005-10-01
A 57-year-old woman developed blindness during treatment for sarcoidosis-induced end-stage renal disease. An initial renal transplantation failed, and hemoaccess was maintained with multiple central catheters and upper extremity prosthetic arteriovenous grafts. A successful second transplantation eliminated her need for hemodialysis, but a right brachial to internal jugular graft remained patent. Progressive visual loss 2 years after transplantation prompted ophthalmic evaluation which initially revealed unilateral left optic nerve edema and visual loss, ultimately worsening over several months to no light perception in the left eye, 20/60 vision in the right eye, and bilateral papilledema. Arteriography demonstrated cerebral venous hypertension attributed to the functioning hemoaccess graft. Permanent graft occlusion normalized the papilledema, and visual field defects in the right eye and visual acuity returned to 20/20 in the right eye.
76 FR 49528 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-10
... had ruptured globe in his right eye due to a traumatic injury he sustained in 2001. The best corrected... his right eye due to an injury sustained in 1978. The best corrected visual acuity in his right eye is.... Harrison Mr. Harrison, 56, has had complete loss of vision in his left eye due an injury in 1971. The best...
Spatial Integration under Contextual Control in a Virtual Environment
ERIC Educational Resources Information Center
Molet, Mikael; Gambet, Boris; Bugallo, Mehdi; Miller, Ralph R.
2012-01-01
The role of context was examined in the selection and integration of independently learned spatial relationships. Using a dynamic 3D virtual environment, participants learned one spatial relationship between landmarks A and B which was established in one virtual context (e.g., A is left of B) and a different spatial relationship which was…
ERIC Educational Resources Information Center
Orman, Evelyn K.; Price, Harry E.; Russell, Christine R.
2017-01-01
Acquiring nonverbal skills necessary to appropriately communicate and educate members of performing ensembles is essential for wind band conductors. Virtual reality learning environments (VRLEs) provide a unique setting for developing these proficiencies. For this feasibility study, we used an augmented immersive VRLE to enhance eye contact, torso…
Time Course of Visual Attention to High-Calorie Virtual Food in Individuals with Bulimic Tendencies.
Kim, Jiwon; Kim, Kiho; Lee, Jang-Han
2016-01-01
The aim of the present study was to use an eye-tracking device to investigate attention bias and its mechanism toward high-calorie virtual food in individuals with bulimic tendencies (BT). A total of 76 participants were divided into two groups: a BT group (n = 38) and a control group (n = 38). The eye movements of all participants were continuously measured while the participants were confronted with pairs of high-calorie, low-calorie, and nonfood virtual stimuli (pictures). It was found that the BT group detected high-calorie food more quickly than they did the low-calorie food and nonfood stimuli, but they also avoided the high-calorie food. These results indicate that individuals with BT automatically allocate their attention toward high-calorie food and, subsequently, try to avoid it. Based on these results, we suggest that this approach-avoidance pattern for high-calorie virtual food could be a factor in the development and maintenance of bulimia symptoms by encouraging individuals with BT to be in conflict with the urge to overeat.
Real-time tracking of visually attended objects in virtual environments and its application to LOD.
Lee, Sungkil; Kim, Gerard Jounghyun; Choi, Seungmoon
2009-01-01
This paper presents a real-time framework for computationally tracking objects visually attended by the user while navigating in interactive virtual environments. In addition to the conventional bottom-up (stimulus-driven) saliency map, the proposed framework uses top-down (goal-directed) contexts inferred from the user's spatial and temporal behaviors, and identifies the most plausibly attended objects among candidates in the object saliency map. The computational framework was implemented using GPU, exhibiting high computational performance adequate for interactive virtual environments. A user experiment was also conducted to evaluate the prediction accuracy of the tracking framework by comparing objects regarded as visually attended by the framework to actual human gaze collected with an eye tracker. The results indicated that the accuracy was in the level well supported by the theory of human cognition for visually identifying single and multiple attentive targets, especially owing to the addition of top-down contextual information. Finally, we demonstrate how the visual attention tracking framework can be applied to managing the level of details in virtual environments, without any hardware for head or eye tracking.
Adalimumab and Non-Arteritic Anterior Ischaemic Optic Neuropathy: A Case Report.
Kinard, Krista; Walsh, Jessica A; Penmetsa, Gopi K; Warner, Judith E A
2014-01-01
Sequential anterior ischaemic optic neuropathy was observed in a patient treated with a tumour necrosis factor α (TNF) inhibitor, adalimumab, for ankylosing spondylitis. He developed decreased visual acuity in the right eye after 17 months of treatment. Findings showed right optic disc oedema with haemorrhages and visual field defect. Adalimumab was discontinued and vision stabilised. After restarting adalimumab, he developed optic neuropathy in the left eye. Findings showed optic disc oedema, with haemorrhages and visual field changes in the left eye. Adalimumab may be associated with optic neuropathy; providers prescribing TNF inhibitors should be aware of optic neuropathy as a potential complication.
Macular function and morphology in acute retinal pigment epithelitis.
Gundogan, Fatih C; Diner, Oktay; Tas, Ahmet; Ilhan, Abdullah; Yolcu, Umit
2014-12-01
A 20-year-old man applied with vision loss in the left eye. Right eye examination was unremarkable. Best-corrected visual acuity (BCVA) in the left eye was 20/200. Fundus examination revealed a few yellow spots within a round-shaped macular lesion. Autofluorescence imaging showed hyperautofluorescence in the lesion. Central amplitudes in multifocal electroretinogram (mfERG) were depressed. The patient reported a rhinopharyngitis 7-10 days before the visual loss. The patient was diagnosed as acute retinal pigment epithelitis. BCVA improved gradually up to 20/20 in 4 weeks. mfERG amplitudes returned to normal. A slight pigmentary distortion was the only residual fundus finding.
Northeast View from Pathfinder Lander
1997-11-04
This panorama of the region to the northeast of the lander was constructed to support the Sojourner Rover Team's plans to conduct an "autonomous traverse" to explore the terrain away from the lander after science objectives in the lander vicinity had been met. The large, relatively bright surface in the foreground, about 10 meters (33 feet) from the spacecraft, in this scene is "Baker's Bench." The large, elongated rock left of center in the middle distance is "Zaphod." This view was produced by combining 8 individual "Superpan" scenes from the left and right eyes of the IMP camera. Each frame consists of 8 individual frames (left eye) and 7 frames (right eye) taken with different color filters that were enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution panchromatic frame that is sharper than an individual frame would be. http://photojournal.jpl.nasa.gov/catalog/PIA01000
Khairallah, Moncef; Kahloun, Rim; Gargouri, Salma; Jelliti, Bechir; Sellami, Dorra; Ben Yahia, Salim; Feki, Jamel
2017-08-01
A 65-year-old man with diabetes and a history of fever of unknown origin 2 weeks earlier complained of sudden decreased vision in the left eye. The patient was diagnosed with bilateral West Nile virus (WNV) chorioretinitis associated with occlusive retinal vasculitis in the left eye. Swept-source optical coherence tomography angiography (SS-OCTA) of the left eye showed extensive, well-delineated, hypointense non-perfusion areas and perifoveal capillary arcade disruption in the superficial capillary plexus, as well as larger non-perfusion areas, capillary rarefaction, and diffuse capillary network attenuation and disorganization in the deep capillary plexus. OCTA may be a valuable tool for noninvasively assessing occlusive retinal vasculitis associated with WNV infection. It allows an accurate detection and precise delineation of areas of retinal capillary nonperfusion in both the superficial and deep capillary plexuses. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:672-675.]. Copyright 2017, SLACK Incorporated.
Canessa, Andrea; Gibaldi, Agostino; Chessa, Manuela; Fato, Marco; Solari, Fabio; Sabatini, Silvio P.
2017-01-01
Binocular stereopsis is the ability of a visual system, belonging to a live being or a machine, to interpret the different visual information deriving from two eyes/cameras for depth perception. From this perspective, the ground-truth information about three-dimensional visual space, which is hardly available, is an ideal tool both for evaluating human performance and for benchmarking machine vision algorithms. In the present work, we implemented a rendering methodology in which the camera pose mimics realistic eye pose for a fixating observer, thus including convergent eye geometry and cyclotorsion. The virtual environment we developed relies on highly accurate 3D virtual models, and its full controllability allows us to obtain the stereoscopic pairs together with the ground-truth depth and camera pose information. We thus created a stereoscopic dataset: GENUA PESTO—GENoa hUman Active fixation database: PEripersonal space STereoscopic images and grOund truth disparity. The dataset aims to provide a unified framework useful for a number of problems relevant to human and computer vision, from scene exploration and eye movement studies to 3D scene reconstruction. PMID:28350382
78 FR 27281 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...) in interstate commerce without meeting the prescribed vision requirement in one eye. If granted, the.... Qualifications of Applicants Allan L. Anthony Mr. Anthony, age 54, has had refractive amblyopia in his left eye...
Face transplant: is it feasible in developing countries?
González-García, Ignacio; Lyra-González, Iván; Medina-Preciado, David; Guerrero-Torres, Alejandro; Ramos-Gallardo, Guillermo; Armendáriz-Borunda, Juan
2013-01-01
This article is based on the case of a 28-year-old woman who was involved in a car accident, with diagnosis of polytrauma, loss of left eye, and second- and third-degree burns over the left midface, rendering an exposed area of 8 cm wide and 19 cm length, ranging from glabella to mandible, with skull exposure and loss of left eye.A latissimus dorsi musculocutaneous free flap was transferred into the defect; left eye and nose prosthetics were necessary to restore normal appearance. Excellent results were obtained; reinsertion to patient's normal life and reinstatement of facial appearance were achieved with minimal costs and no postsurgical complications.Analysis of the current situation in developing countries demonstrates that technique and infrastructure do not represent a real challenge to carry on face transplants. However, socioeconomic reality in these societies makes it difficult to establish face transplant as a feasible therapeutic opportunity for the overwhelming majority of patients who are victims of severe facial damage.Therefore, strategies such as latissimus dorsi free flap remains as an excellent therapy to face off our complex facial reconstructive challenges in developing countries such as Mexico.
Choroidal metastasis from early rectal cancer: Case report and literature review
Tei, Mitsuyoshi; Wakasugi, Masaki; Akamatsu, Hiroki
2014-01-01
INTRODUCTION Choroidal metastasis from colorectal cancer is rare, and there have been no reported cases of such metastasis from early colorectal cancer. We report a case of choroidal metastasis from early rectal cancer. PRESENTATION OF CASE A 61 year-old-man experienced myodesopsia in the left eye 2 years and 6 months after primary rectal surgery for early cancer, and was diagnosed with left choroidal metastasis and multiple lung metastases. Radiotherapy was initiated for the left eye and systemic chemotherapy is initiated for the multiple lung metastases. The patient is living 2 years and 3 months after the diagnosis of choroidal metastasis without signs of recurrence in the left eye, and continues to receive systemic chemotherapy for multiple lung metastases. DISCUSSION Current literatures have few recommendations regarding the appropriate treatment of choroidal metastasis from colorectal cancer, but an aggressive multi-disciplinary approach may be effective in local regression. CONCLUSION This is the first report of choroidal metastasis from early rectal cancer. We consider it important to enforce systemic chemotherapy in addition to radiotherapy for choroidal metastasis from colorectal cancer. PMID:25460493
Choroidal metastasis from early rectal cancer: Case report and literature review.
Tei, Mitsuyoshi; Wakasugi, Masaki; Akamatsu, Hiroki
2014-01-01
Choroidal metastasis from colorectal cancer is rare, and there have been no reported cases of such metastasis from early colorectal cancer. We report a case of choroidal metastasis from early rectal cancer. A 61 year-old-man experienced myodesopsia in the left eye 2 years and 6 months after primary rectal surgery for early cancer, and was diagnosed with left choroidal metastasis and multiple lung metastases. Radiotherapy was initiated for the left eye and systemic chemotherapy is initiated for the multiple lung metastases. The patient is living 2 years and 3 months after the diagnosis of choroidal metastasis without signs of recurrence in the left eye, and continues to receive systemic chemotherapy for multiple lung metastases. Current literatures have few recommendations regarding the appropriate treatment of choroidal metastasis from colorectal cancer, but an aggressive multi-disciplinary approach may be effective in local regression. This is the first report of choroidal metastasis from early rectal cancer. We consider it important to enforce systemic chemotherapy in addition to radiotherapy for choroidal metastasis from colorectal cancer. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
IDIOPATHIC MULTIFOCAL CHOROIDITIS PRESENTING WITH A TRANSIENT PERIPAPILLARY WHITE RING.
Gattoussi, Sarra; Ghadiali, Quraish; Dolz-Marco, Rosa; Freund, K Bailey
2017-11-22
We describe with multimodal imaging the presentation and follow-up for a patient with idiopathic multifocal choroiditis and a transient peripapillary white ring. Case report. A 39-year-old Asian woman was initially seen for an evaluation of lattice degeneration in 2015. Her medical history included Graves disease and psoriasis. Best-corrected visual acuity was 20/25 in her right eye and 20/25 in her left eye. Ultra-widefield fundus autofluorescence imaging showed a curvilinear hyperautofluorescent line in her right eye. One year later, the patient returned complaining of floaters in her right eye for 1 month. Her visual acuity was unchanged. Funduscopic examination showed new inflammatory yellowish lesions in the right eye corresponding to hyperreflective sub-retinal pigment epithelium lesions on structural spectral domain optical coherence tomography. Fluorescein angiography showed corresponding late staining of these active lesions. Late-phase indocyanine green angiography showed multiple nummular hypocyanescent dots. Ultra-widefield fundus autofluorescence showed large areas of hyperautofluorescence. The patient was started on a 60-mg oral prednisone taper and demonstrated subsequent regression of the inflammatory lesions. Ten months later, the patient returned emergently with complaints of floaters in both eyes for 2 days and a new temporal scotoma in her left eye. Funduscopic examination demonstrated a white ring around the optic nerve of the left eye corresponding to a hyperautofluorescent lesion. Ultra-widefield fundus autofluorescence showed new areas of hyperautofluorescence in both eyes. Structural spectral domain optical coherence tomography showed new sub-retinal pigment epithelium inflammatory lesions and a disruption of the ellipsoid zone in both eyes. The patient was again treated with a 60-mg oral prednisone taper and demonstrated subsequent restoration of the ellipsoid zone. To our knowledge, this is the first report of a transient annular white ring occurring in a case of multifocal choroiditis. There was marked restoration of the disrupted ellipsoid zone after treatment with oral corticosteroids.
NASA Astrophysics Data System (ADS)
Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.
2017-02-01
Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.
Oka, Noriyuki; Yoshino, Kayoko; Yamamoto, Kouji; Takahashi, Hideki; Li, Shuguang; Sugimachi, Toshiyuki; Nakano, Kimihiko; Suda, Yoshihiro; Kato, Toshinori
2015-01-01
Objectives In the brain, the mechanisms of attention to the left and the right are known to be different. It is possible that brain activity when driving also differs with different horizontal road alignments (left or right curves), but little is known about this. We found driver brain activity to be different when driving on left and right curves, in an experiment using a large-scale driving simulator and functional near-infrared spectroscopy (fNIRS). Research Design and Methods The participants were fifteen healthy adults. We created a course simulating an expressway, comprising straight line driving and gentle left and right curves, and monitored the participants under driving conditions, in which they drove at a constant speed of 100 km/h, and under non-driving conditions, in which they simply watched the screen (visual task). Changes in hemoglobin concentrations were monitored at 48 channels including the prefrontal cortex, the premotor cortex, the primary motor cortex and the parietal cortex. From orthogonal vectors of changes in deoxyhemoglobin and changes in oxyhemoglobin, we calculated changes in cerebral oxygen exchange, reflecting neural activity, and statistically compared the resulting values from the right and left curve sections. Results Under driving conditions, there were no sites where cerebral oxygen exchange increased significantly more during right curves than during left curves (p > 0.05), but cerebral oxygen exchange increased significantly more during left curves (p < 0.05) in the right premotor cortex, the right frontal eye field and the bilateral prefrontal cortex. Under non-driving conditions, increases were significantly greater during left curves (p < 0.05) only in the right frontal eye field. Conclusions Left curve driving was thus found to require more brain activity at multiple sites, suggesting that left curve driving may require more visual attention than right curve driving. The right frontal eye field was activated under both driving and non-driving conditions. PMID:25993263
Oka, Noriyuki; Yoshino, Kayoko; Yamamoto, Kouji; Takahashi, Hideki; Li, Shuguang; Sugimachi, Toshiyuki; Nakano, Kimihiko; Suda, Yoshihiro; Kato, Toshinori
2015-01-01
In the brain, the mechanisms of attention to the left and the right are known to be different. It is possible that brain activity when driving also differs with different horizontal road alignments (left or right curves), but little is known about this. We found driver brain activity to be different when driving on left and right curves, in an experiment using a large-scale driving simulator and functional near-infrared spectroscopy (fNIRS). The participants were fifteen healthy adults. We created a course simulating an expressway, comprising straight line driving and gentle left and right curves, and monitored the participants under driving conditions, in which they drove at a constant speed of 100 km/h, and under non-driving conditions, in which they simply watched the screen (visual task). Changes in hemoglobin concentrations were monitored at 48 channels including the prefrontal cortex, the premotor cortex, the primary motor cortex and the parietal cortex. From orthogonal vectors of changes in deoxyhemoglobin and changes in oxyhemoglobin, we calculated changes in cerebral oxygen exchange, reflecting neural activity, and statistically compared the resulting values from the right and left curve sections. Under driving conditions, there were no sites where cerebral oxygen exchange increased significantly more during right curves than during left curves (p > 0.05), but cerebral oxygen exchange increased significantly more during left curves (p < 0.05) in the right premotor cortex, the right frontal eye field and the bilateral prefrontal cortex. Under non-driving conditions, increases were significantly greater during left curves (p < 0.05) only in the right frontal eye field. Left curve driving was thus found to require more brain activity at multiple sites, suggesting that left curve driving may require more visual attention than right curve driving. The right frontal eye field was activated under both driving and non-driving conditions.
The Twin Peaks in 3-D, as Viewed by the Mars Pathfinder IMP Camera
NASA Technical Reports Server (NTRS)
1997-01-01
The Twin Peaks are modest-size hills to the southwest of the Mars Pathfinder landing site. They were discovered on the first panoramas taken by the IMP camera on the 4th of July, 1997, and subsequently identified in Viking Orbiter images taken over 20 years ago. The peaks are approximately 30-35 meters (-100 feet) tall. North Twin is approximately 860 meters (2800 feet) from the lander, and South Twin is about a kilometer away (3300 feet). The scene includes bouldery ridges and swales or 'hummocks' of flood debris that range from a few tens of meters away from the lander to the distance of the South Twin Peak. The large rock at the right edge of the scene is nicknamed 'Hippo'. This rock is about a meter (3 feet) across and 25 meters (80 feet) distant.
This view of the Twin Peaks was produced by combining 4 individual 'Superpan' scenes from the left and right eyes of the IMP camera to cover both peaks. Each frame consists of 8 individual frames (left eye) and 7 frames (right eye) taken with different color filters that were enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution pancromatic frame that is sharper than an individual frame would be.The anaglyph view of the Twin Peaks was produced by combining the left and right eye mosaics (above) by assigning the left eye view to the red color plane and the right eye view to the green and blue color planes (cyan), to produce a stereo anaglyph mosaic. This mosaic can be viewed in 3-D on your computer monitor or in color print form by wearing red-blue 3-D glasses.Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. The Jet Propulsion Laboratory, Pasadena, CA, developed and manages the Mars Pathfinder mission for NASA's Office of Space Science, Washington, D.C. JPL is a division of the California Institute of Technology (Caltech). The IMP was developed by the University of Arizona Lunar and Planetary Laboratory under contract to JPL. Peter Smith is the Principal Investigator.Click below to see the left and right views individually. [figure removed for brevity, see original site] Left [figure removed for brevity, see original site] RightGoal-Directed Movement Enhances Body Representation Updating
Wen, Wen; Muramatsu, Katsutoshi; Hamasaki, Shunsuke; An, Qi; Yamakawa, Hiroshi; Tamura, Yusuke; Yamashita, Atsushi; Asama, Hajime
2016-01-01
Body representation refers to perception, memory, and cognition related to the body and is updated continuously by sensory input. The present study examined the influence of goals on body representation updating with two experiments of the rubber hand paradigm. In the experiments, participants moved their hidden left hands forward and backward either in response to instruction to touch a virtual object or without any specific goal, while a virtual left hand was presented 250 mm above the real hand and moved in synchrony with the real hand. Participants then provided information concerning the perceived heights of their real left hands and rated their sense of agency and ownership of the virtual hand. Results of Experiment 1 showed that when participants moved their hands with the goal of touching a virtual object and received feedback indicating goal attainment, the perceived positions of their real hands shifted more toward that of the virtual hand relative to that in the condition without a goal, indicating that their body representations underwent greater modification. Furthermore, results of Experiment 2 showed that the effect of goal-directed movement occurred in the active condition, in which participants moved their own hands, but did not occur in the passive condition, in which participants’ hands were moved by the experimenter. Therefore, we concluded that the sense of agency probably contributed to the updating of body representation involving goal-directed movement. PMID:27445766
Regenbogen, Christina; Herrmann, Manfred; Fehr, Thorsten
2010-01-01
Studies investigating the effects of violent computer and video game playing have resulted in heterogeneous outcomes. It has been assumed that there is a decreased ability to differentiate between virtuality and reality in people that play these games intensively. FMRI data of a group of young males with (gamers) and without (controls) a history of long-term violent computer game playing experience were obtained during the presentation of computer game and realistic video sequences. In gamers the processing of real violence in contrast to nonviolence produced activation clusters in right inferior frontal, left lingual and superior temporal brain regions. Virtual violence activated a network comprising bilateral inferior frontal, occipital, postcentral, right middle temporal, and left fusiform regions. Control participants showed extended left frontal, insula and superior frontal activations during the processing of real, and posterior activations during the processing of virtual violent scenarios. The data suggest that the ability to differentiate automatically between real and virtual violence has not been diminished by a long-term history of violent video game play, nor have gamers' neural responses to real violence in particular been subject to desensitization processes. However, analyses of individual data indicated that group-related analyses reflect only a small part of actual individual different neural network involvement, suggesting that the consideration of individual learning history is sufficient for the present discussion.
Beaked Whale Necropsy Findings for Strandings in the Bahamas, Puerto Rico, and Madeira, 1999-2002
2005-11-01
CITES export permit to Dr. Freitas . The right and left eyes both have periorbital staining and surrounding ring hemorrhages. The left eye has contusions...skull, all were normally configured with no remarkable pathology. The odd skull was that of a presumed adult male with an aberrant right jaw and ear...tentative ID of NEPST531, stranded on Vieques, January 1998. The right mandible had two significant healed fractures (evidenced by displaced segments
Beaked Whale Necropsy Findings for Strandings in the Bahamas, Puerto Rico, and Madeira, 1999-2002
2005-11-01
export permit to Dr. Freitas . The right and left eyes both have periorbital staining and surrounding ring hemorrhages. The left eye has contusions...all were normally configured with no remarkable pathology. The odd skull was that of a presumed adult male with an aberrant right jaw and ear...tentative ID of NEPST531, stranded on Vieques, January 1998. The right mandible had two significant healed fractures (evidenced by displaced segments
Unilateral microphthalmia or anophthalmia in eight pythons (Pythonidae).
Da Silva, Mari-Ann O; Bertelsen, Mads F; Wang, Tobias; Pedersen, Michael; Lauridsen, Henrik; Heegaard, Steffen
2015-01-01
To provide morphological descriptions of microphthalmia or anophthalmia in eight pythons using microcomputerized tomography (μCT), magnetic resonance imaging (MRI), and histopathology. Seven Burmese pythons (Python bivittatus) and one ball python (P. regius) with clinically normal right eyes and an abnormal or missing left eye. At the time of euthanasia, four of the eight snakes underwent necropsy. Hereafter, the heads of two Burmese pythons and one ball python were examined using μCT, and another Burmese python was subjected to MRI. Following these procedures, the heads of these four pythons along with the heads of an additional three Burmese pythons were prepared for histology. All eight snakes had left ocular openings seen as dermal invaginations between 0.2 and 2.0 mm in diameter. They also had varying degrees of malformations of the orbital bones and a limited presence of nervous, glandular, and muscle tissue in the posterior orbit. Two individuals had small but identifiable eyes. Furthermore, remnants of the pigmented embryonic framework of the hyaloid vessels were found in the anophthalmic snakes. Necropsies revealed no other macroscopic anomalies. Eight pythons with unilateral left-sided microphthalmia or anophthalmia had one normal eye and a left orbit with malformed or incompletely developed ocular structures along with remnants of fetal structures. These cases lend further information to a condition that is often seen in snakes, but infrequently described. © 2014 American College of Veterinary Ophthalmologists.
Renaud, Patrice; Trottier, Dominique; Nolet, Kevin; Rouleau, Joanne L; Goyette, Mathieu; Bouchard, Stéphane
2014-04-01
The eye movements and penile responses of 20 male participants were recorded while they were immersed with virtual sexual stimuli. These participants were divided into two groups according to their capacity to focus their attention in immersion (high and low focus). In order to understand sexual self-regulation better, we subjected participants to three experimental conditions: (a) immersion with a preferred sexual stimulus, without sexual inhibition; (b) immersion with a preferred sexual stimulus, with sexual inhibition; and (c) immersion with a neutral stimulus. A significant difference was observed between the effects of each condition on erectile response and scanpath. The groups differed on self-regulation of their erectile responses and on their scanpath patterns. High focus participants had more difficulties than low focus participants with inhibiting their sexual responses and displayed less scattered eye movement trajectories over the critical areas of the virtual sexual stimuli. Results are interpreted in terms of sexual self-regulation and cognitive absorption in virtual immersion. In addition, the use of validated virtual sexual stimuli is presented as a methodological improvement over static and moving pictures, since it paves the way for the study of the role of social interaction in an ecologically valid and well-controlled way.
NASA Astrophysics Data System (ADS)
Farkas, Attila J.; Hajnal, Alen; Shiratuddin, Mohd F.; Szatmary, Gabriella
In this paper, we propose a novel approach of using interactive virtual environment technology in Vision Restoration Therapy caused by Traumatic Brain Injury. We called the new system Interactive Visuotactile Virtual Environment and it holds a promise of expanding the scope of already existing rehabilitation techniques. Traditional vision rehabilitation methods are based on passive psychophysical training procedures, and can last up to six months before any modest improvements can be seen in patients. A highly immersive and interactive virtual environment will allow the patient to practice everyday activities such as object identification and object manipulation through the use 3D motion sensoring handheld devices such data glove or the Nintendo Wiimote. Employing both perceptual and action components in the training procedures holds the promise of more efficient sensorimotor rehabilitation. Increased stimulation of visual and sensorimotor areas of the brain should facilitate a comprehensive recovery of visuomotor function by exploiting the plasticity of the central nervous system. Integrated with a motion tracking system and an eye tracking device, the interactive virtual environment allows for the creation and manipulation of a wide variety of stimuli, as well as real-time recording of hand-, eye- and body movements and coordination. The goal of the project is to design a cost-effective and efficient vision restoration system.
Mass production of holographic transparent components for augmented and virtual reality applications
NASA Astrophysics Data System (ADS)
Russo, Juan Manuel; Dimov, Fedor; Padiyar, Joy; Coe-Sullivan, Seth
2017-06-01
Diffractive optics such as holographic optical elements (HOEs) can provide transparent and narrow band components with arbitrary incident and diffracted angles for near-to-eye commercial electronic products for augmented reality (AR), virtual reality (VR), and smart glass applications. In this paper, we will summarize the operational parameters and general optical geometries relevant for near-to-eye displays, the holographic substrates available for these applications, and their performance characteristics and ease of manufacture. We will compare the holographic substrates available in terms of fabrication, manufacturability, and end-user performance characteristics. Luminit is currently emplacing the manufacturing capacity to serve this market, and this paper will discuss the capabilities and limitations of this unique facility.
Anophthalmia-plus syndrome with unusual findings. A clinical report and review of the literature.
Cayir, A; Tasdemir, S; Eroz, R; Yuce, I; Orbak, Z; Tatar, A
2013-01-01
We present a male child at 3 years old with Anophthalmia-Plus Syndrome (APS). He has asymmetry of the face and head, left choanal atresia, a sunken facial appearance, microphthalmia in the right eye, severe microphthalmia in the left eye, bilateral low-set ears, scarring from cleft palate surgery. Magnetic resonance imaging (MRI) sections revealed decreased right globe volume, an undeveloped left globe, decreased left optical nerve thickness, Chiari type 2 malformation, left choanal atresia and cleft palate. Echocardiography and abdominal ultrasonography were normal. The patient has a 45 dB conductive hearing loss in the left ear. Repeated thyroid function tests were evaluated as compatible with central hypothyroidism. We report a Fryns Anophthalmia-Plus Syndrome in a child with unusual findings including central hypothyroidism, chiari type 2 malformation, conductive hearing loss and developmental regression. Summary of the features reported in the present case and all 14 previous cases that might be defined as APS.
Meibomian Gland Dysfunction and Treatment (Posterior Blepharitis)
... if left untreated, MGD can cause or exacerbate dry eye symptoms and eyelid inflammation. The oil glands become ... in permanent changes in the tear film and dry eyes. Symptoms include: ... Stickiness/ Crustiness Watering ...
Lateralization of magnetic compass orientation in a migratory bird
NASA Astrophysics Data System (ADS)
Wiltschko, Wolfgang; Traudt, Joachim; Güntürkün, Onur; Prior, Helmut; Wiltschko, Roswitha
2002-10-01
Lateralization of brain functions, once believed to be a human characteristic, has now been found to be widespread among vertebrates. In birds, asymmetries of visual functions are well studied, with each hemisphere being specialized for different tasks. Here we report lateralized functions of the birds' visual system associated with magnetoperception, resulting in an extreme asymmetry of sensing the direction of the magnetic field. We found that captive migrants tested in cages with the magnetic field as the only available orientation cue were well oriented in their appropriate migratory direction when using their right eye only, but failed to show a significant directional preference when using their left eye. This implies that magnetoreception for compass orientation, assumed to take place in the eyes alongside the visual processes, is strongly lateralized, with a marked dominance of the right eye/left brain hemisphere.
Monocular zones in stereoscopic scenes: A useful source of information for human binocular vision?
NASA Astrophysics Data System (ADS)
Harris, Julie M.
2010-02-01
When an object is closer to an observer than the background, the small differences between right and left eye views are interpreted by the human brain as depth. This basic ability of the human visual system, called stereopsis, lies at the core of all binocular three-dimensional (3-D) perception and related technological display development. To achieve stereopsis, it is traditionally assumed that corresponding locations in the right and left eye's views must first be matched, then the relative differences between right and left eye locations are used to calculate depth. But this is not the whole story. At every object-background boundary, there are regions of the background that only one eye can see because, in the other eye's view, the foreground object occludes that region of background. Such monocular zones do not have a corresponding match in the other eye's view and can thus cause problems for depth extraction algorithms. In this paper I will discuss evidence, from our knowledge of human visual perception, illustrating that monocular zones do not pose problems for our human visual systems, rather, our visual systems can extract depth from such zones. I review the relevant human perception literature in this area, and show some recent data aimed at quantifying the perception of depth from monocular zones. The paper finishes with a discussion of the potential importance of considering monocular zones, for stereo display technology and depth compression algorithms.
Furdová, Alena; Sramka, Miron; Thurzo, Andrej; Furdová, Adriana
2017-01-01
Objective The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery. Methods The software for segmentation (3D Slicer) created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D®) and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid. Results In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient’s eye with intraocular tumor. In the period 2001–2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma) were treated. The median tumor volume was 0.5 cm3 (0.2–1.6 cm3). The radiation dose was 35.0 Gy by 99% of dose volume histogram. Conclusion The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures. PMID:28203052
77 FR 56261 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-12
... Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...) in interstate commerce without meeting the prescribed vision requirement in one eye. If granted, the... had loss of vision in his left eye due to a traumatic incidence that occured in 1990. The best...
Radiation dose to physicians’ eye lens during interventional radiology
NASA Astrophysics Data System (ADS)
Bahruddin, N. A.; Hashim, S.; Karim, M. K. A.; Sabarudin, A.; Ang, W. C.; Salehhon, N.; Bakar, K. A.
2016-03-01
The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure.
MACULAR HOLES, VITELLIFORM LESIONS, AND MIDPERIPHERAL RETINOSCHISIS IN ALPORT SYNDROME.
Thomas, Akshay S; Baynham, Justin T; Flaxel, Christina J
2016-01-01
To describe the retinal findings in two cases of Alport syndrome. Observational case series. The clinical findings of the two patients were documented with color fundus photography and high resolution spectral domain optical coherence tomography. Patient 1 was found to have fleck retinopathy in both eyes, inner retinal thinning in the right eye and a full-thickness macular hole in the left eye. Patient 2 was found to have a full-thickness macular hole in the right eye as well as retinoschisis in the temporal macula in the right eye. The left eye revealed inner retinal thinning involving the fovea, a vitelliform lesion of the temporal macula and midperipheral retinoschisis involving multiple retinal layers. Retinal abnormalities including fleck retinopathy, retinal thinning, macular holes, retinoschisis, and vitelliform lesions are variably present in Alport syndrome. This is only the second report of a vitelliform lesion in a patient with Alport syndrome and the first report of midperipheral retinoschisis. The array of retinal findings is believed to reflect a dysfunctional Type IV collagen present in the internal limiting membrane and Bruch membrane.
Unilateral pigmentary retinopathy--a review of literature and case presentation.
Stamate, Alina-Cristina; Burcea, Marian; Zemba, Mihail
2016-01-01
To report a rare case of unilateral pigmentary retinopathy and describe the clinical and visual field characteristics of this particular case. We present the case of a 30-year-old male patient with a gradual loss of the visual field on his left eye (LE) for the past 10 years, with further gradual painless loss of his central visual field in the last year, and no similar symptoms in his right eye. His past medical and ocular history were unremarkable. No family history of acquired or inherited diseases was determined. Based on the history, clinical findings, and visual field examination, the diagnosis of unilateral pigmentary retinopathy was established. Visual acuity and visual field in the left eye (LE) were severely affected, while in the right eye (RE), they were completely normal. In this case, distinct features of pigmentary retinopathy were observed only in one eye, with the fellow eye being unaffected. The diagnosis requires a long follow-up period, visual field and electrophysiological testing to rule out a delayed onset of a bilateral form of pigmentary retinopathy.
Hidden Communicative Competence: Case Study Evidence Using Eye-Tracking and Video Analysis
ERIC Educational Resources Information Center
Grayson, Andrew; Emerson, Anne; Howard-Jones, Patricia; O'Neil, Lynne
2012-01-01
A facilitated communication (FC) user with an autism spectrum disorder produced sophisticated texts by pointing, with physical support, to letters on a letterboard while their eyes were tracked and while their pointing movements were video recorded. This FC user has virtually no independent means of expression, and is held to have no literacy…
What Does the Eye See? Reading Online Primary Source Photographs in History
ERIC Educational Resources Information Center
Levesque, Stephane; Ng-A-Fook, Nicholas; Corrigan, Julie
2014-01-01
This exploratory study looks at how a sample of preservice teachers and historians read visuals in the context of school history. The participants used eye tracking technology and think-aloud protocol, as they examined a series of online primary source photographs from a virtual exhibit. Voluntary participants (6 students and 2 professional…
Concurrent Acute Retinal Necrosis in a Patient With Iridocorneal Endothelial Syndrome.
Vignesh, A P; Srinivasan, Renuka
2016-11-01
To report a rare case of concurrent acute retinal necrosis in a patient with iridocorneal endothelial syndrome (ICE). Case report. A 42-year-old woman showed acute diminution of vision in the right eye. Her fundus examination revealed features of acute retinal necrosis. She had also experienced gradual diminution of vision in her left eye for 5 years. The examination of her left eye revealed corneal edema with mild corectopia and increased intraocular pressure with abnormal endothelium on specular microscopy pointing to a diagnosis of ICE. This is a rare case where concurrent acute retinal necrosis and ICE syndrome are present in the same patient, possibly pointing to a common viral etiology causing both entities.
An unusual cause of central retinal artery occlusion: acquired immunodeficiency syndrome.
Erdol, H; Turk, A; Caylan, R
2007-01-01
In patients with acquired immunodeficiency syndrome (AIDS), disturbances in the circulation of retinal vessels are mostly encountered at the microvascular level. Rarely observed large retinal vessel occlusions frequently affect retinal veins. A 32-year-old woman was admitted to the authors' clinic with sudden loss of vision. Her clinical and ophthalmologic examinations and laboratory tests were carried out and the results were evaluated. The patient's history revealed a diagnosis of AIDS established 5 years ago. Her corrected visual acuity was limited to light perception in the right eye and 20/60 in the left eye. There was afferent pupillary defect in the right eye. Posterior segment examination demonstrated central retinal artery occlusion in the right eye and cotton-wool spots in the left eye. The clinical examination and laboratory test results did not reveal any comorbid disease state that can contribute to this presentation. As thrombi may develop in patients with human immunodeficiency virus infection, they should be closely followed up for the development of vasoocclusive disease.
PRESENTATION OF CENTRAL SEROUS CHORIORETINOPATHY IN TWO HUSBAND AND WIFE COUPLES.
Kanesa-Thasan, Aditya; Fawzi, Amani A; Gill, Manjot K
2018-01-01
Central serous chorioretinopathy (CSC) is a disease in which serous detachment of the neurosensory retina occurs over an area of leakage from the choriocapillaris through the retinal pigment epithelium. Associations have been drawn between high-stress personality types and steroid exposure. This article aims to describe a unique case series of two husband and wife couples with CSC. All methods were approved by the authors' institution's institutional review board. History, physical examination, and imaging data were obtained from the electronic medical records of the patients in question and from the providers who cared for these patients. Couple 1: A 35-year-old man presented with "dark spots" in his right eye. He reported no recent steroid use. Visual acuity at presentation was 20/30 in the right eye and 20/20 in the left eye. On fundus examination, there was subretinal fluid in the right eye. His wife presented on the same day with a "wavy section" in the right eye for 6 weeks. She also had no recent steroid use. Visual acuity at presentation was 20/20 in both eyes with blunting of the foveal reflex in the right eye. Optical coherence tomography showed a thick choroid with a pigment epithelial detachment in the right eye. Couple 2: A 34-year-old man presented with "blurry vision" in his right eye for one month. He was taking oral and nasal steroids for chronic sinusitis. Visual acuity was 20/30 in the right eye and 20/20 in the left eye. Fluorescein angiography and indocyanine green confirmed the diagnosis of CSC. After 3 months of persistent subretinal fluid, he received photodynamic therapy in the right eye. Three days after his photodynamic therapy, his 38-year-old wife presented with subjective blurring in both eyes. Visual acuity was 20/20 in both eyes, but optical coherence tomography showed thick choroid in both eyes, a large central pigment epithelial detachment in the right eye, and 3 small pigment epithelial detachments in the left eye. She had no history of steroid use but did admit to high stress recently. All the patients in this case series were diagnosed with CSC. This is the first series to describe the simultaneous occurrence of CSC in spouses. Possible explanations for these presentations may include shared external stressors or secondary steroid exposure. Clinicians may consider inquiring about family members or cohabitants with similar symptoms if CSC is suspected.
Does the perception of moving eyes trigger reflexive visual orienting in autism?
Swettenham, John; Condie, Samantha; Campbell, Ruth; Milne, Elizabeth; Coleman, Mike
2003-01-01
Does movement of the eyes in one or another direction function as an automatic attentional cue to a location of interest? Two experiments explored the directional movement of the eyes in a full face for speed of detection of an aftercoming location target in young people with autism and in control participants. Our aim was to investigate whether a low-level perceptual impairment underlies the delay in gaze following characteristic of autism. The participants' task was to detect a target appearing on the left or right of the screen either 100 ms or 800 ms after a face cue appeared with eyes averting to the left or right. Despite instructions to ignore eye-movement in the face cue, people with autism and control adolescents were quicker to detect targets that had been preceded by an eye movement cue congruent with target location compared with targets preceded by an incongruent eye movement cue. The attention shifts are thought to be reflexive because the cue was to be ignored, and because the effect was found even when cue-target duration was short (100 ms). Because (experiment two) the effect persisted even when the face was inverted, it would seem that the direction of movement of eyes can provide a powerful (involuntary) cue to a location. PMID:12639330
Street crossing behavior in younger and older pedestrians: an eye- and head-tracking study.
Zito, G A; Cazzoli, D; Scheffler, L; Jäger, M; Müri, R M; Mosimann, U P; Nyffeler, T; Mast, F W; Nef, T
2015-12-29
Crossing a street can be a very difficult task for older pedestrians. With increased age and potential cognitive decline, older people take the decision to cross a street primarily based on vehicles' distance, and not on their speed. Furthermore, older pedestrians tend to overestimate their own walking speed, and could not adapt it according to the traffic conditions. Pedestrians' behavior is often tested using virtual reality. Virtual reality presents the advantage of being safe, cost-effective, and allows using standardized test conditions. This paper describes an observational study with older and younger adults. Street crossing behavior was investigated in 18 healthy, younger and 18 older subjects by using a virtual reality setting. The aim of the study was to measure behavioral data (such as eye and head movements) and to assess how the two age groups differ in terms of number of safe street crossings, virtual crashes, and missed street crossing opportunities. Street crossing behavior, eye and head movements, in older and younger subjects, were compared with non-parametric tests. The results showed that younger pedestrians behaved in a more secure manner while crossing a street, as compared to older people. The eye and head movements analysis revealed that older people looked more at the ground and less at the other side of the street to cross. The less secure behavior in street crossing found in older pedestrians could be explained by their reduced cognitive and visual abilities, which, in turn, resulted in difficulties in the decision-making process, especially under time pressure. Decisions to cross a street are based on the distance of the oncoming cars, rather than their speed, for both groups. Older pedestrians look more at their feet, probably because of their need of more time to plan precise stepping movement and, in turn, pay less attention to the traffic. This might help to set up guidelines for improving senior pedestrians' safety, in terms of speed limits, road design, and mixed physical-cognitive trainings.
1954-01-01
THE AMERICAN OPTICAL VISION TESTER AND THE ARMED FORCES FAR VISUAL ACUITY TEST Comparisons were made of the visual acuity scores of 100 enlisted men on ...the American Optical Vision Tester (with Sloan plates) and on the Armed Forces Far Visual Acuity test. Order of presentation was: AO-left eye, AO...right eye, AFFVAT-left, AFVTAT-right. Correlation coefficients between AO and AFFVAT were around .89. Dispersion of acuity scores was about the same on
Central amaurosis induced by an intraocular, posttraumatic fibrosarcoma in a cat.
Barrett, P M; Merideth, R E; Alarcon, F L
1995-01-01
A 12-year-old, castrated male, domestic shorthair cat with a previous penetrating trauma to the left globe which progressed to a phthisical eye presented for acute blindness. Ophthalmic examination and electroretinography of the right eye were found to be normal. Following euthanasia, gross and microscopic examinations were completed. A left intraocular, posttraumatic fibrosarcoma with extension to the optic nerve and chiasm and induced right optic nerve fiber degeneration at the optic chiasm with necrosis leading to central amaurosis were diagnosed.
Opportunity's Surroundings After Sol 1820 Drive (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11841 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11841 NASA's Mars Exploration Rover Opportunity used its navigation camera to take the images combined into this full-circle view of the rover's surroundings during the 1,820th to 1,822nd Martian days, or sols, of Opportunity's surface mission (March 7 to 9, 2009). This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 20.6 meters toward the northwest on Sol 1820 before beginning to take the frames in this view. Tracks from that drive recede southwestward. For scale, the distance between the parallel wheel tracks is about 1 meter (about 40 inches). The terrain in this portion of Mars' Meridiani Planum region includes dark-toned sand ripples and small exposures of lighter-toned bedrock. This view is presented as a cylindrical-perspective projection with geometric seam correction.Optoelectronic stereoscopic device for diagnostics, treatment, and developing of binocular vision
NASA Astrophysics Data System (ADS)
Pautova, Larisa; Elkhov, Victor A.; Ovechkis, Yuri N.
2003-08-01
Operation of the device is based on alternative generation of pictures for left and right eyes on the monitor screen. Controller gives pulses on LCG so that shutter for left or right eye opens synchronously with pictures. The device provides frequency of switching more than 100 Hz, and that is why the flickering is absent. Thus, a separate demonstration of images to the left eye or to the right one in turn is obtained for patients being unaware and creates the conditions of binocular perception clsoe to natural ones without any additional separation of vision fields. LC-cell transfer characteristic coodination with time parameters of monitor screen has enabled to improve stereo image quality. Complicated problem of computer stereo images with LC-glasses is so called 'ghosts' - noise images that come to blocked eye. We reduced its influence by adapting stereo images to phosphor and LC-cells characteristics. The device is intended for diagnostics and treatment of stabismus, amblyopia and other binocular and stereoscopic vision impairments, for cultivating, training and developing of stereoscopic vision, for measurements of horizontal and vertical phoria, phusion reserves, the stereovision acuity and some else, for fixing central scotoma borders, as well as suppression scotoma in strabismus too.
Look into Our "Eyes" and See the Future
NASA Astrophysics Data System (ADS)
Hussey, K.
2016-12-01
There are great plans ahead for NASA's "Eyes on…" suite of products. Come and see the latest advances and new features in "Eyes on the Earth", "Eyes on the Solar System" and "Eyes on Exoplanets", NASA's real-time, 3D interactive visualization tools that allow users to virtually explore the Earth, our Solar System and well beyond. This presentation will provide live demonstrations of some exciting new features in each of these products and how they may be used to inspire the next generation of students and educators in STEM. Relive Juno's majestic insertion into orbit around Jupiter and preview Cassini's "Grand Finale" as it prepares to plunge into the clouds of Saturn in September of 2017.
Light and dark adaptation of visually perceived eye level controlled by visual pitch.
Matin, L; Li, W
1995-01-01
The pitch of a visual field systematically influences the elevation at which a monocularly viewing subject sets a target so as to appear at visually perceived eye level (VPEL). The deviation of the setting from true eye level average approximately 0.6 times the angle of pitch while viewing a fully illuminated complexly structured visual field and is only slightly less with one or two pitched-from-vertical lines in a dark field (Matin & Li, 1994a). The deviation of VPEL from baseline following 20 min of dark adaptation reaches its full value less than 1 min after the onset of illumination of the pitched visual field and decays exponentially in darkness following 5 min of exposure to visual pitch, either 30 degrees topbackward or 20 degrees topforward. The magnitude of the VPEL deviation measured with the dark-adapted right eye following left-eye exposure to pitch was 85% of the deviation that followed pitch exposure of the right eye itself. Time constants for VPEL decay to the dark baseline were the same for same-eye and cross-adaptation conditions and averaged about 4 min. The time constants for decay during dark adaptation were somewhat smaller, and the change during dark adaptation extended over a 16% smaller range following the viewing of the dim two-line pitched-from-vertical stimulus than following the viewing of the complex field. The temporal course of light and dark adaptation of VPEL is virtually identical to the course of light and dark adaptation of the scotopic luminance threshold following exposure to the same luminance. We suggest that, following rod stimulation along particular retinal orientations by portions of the pitched visual field, the storage of the adaptation process resides in the retinogeniculate system and is manifested in the focal system as a change in luminance threshold and in the ambient system as a change in VPEL. The linear model previously developed to account for VPEL, which was based on the interaction of influences from the pitched visual field and extraretinal influences from the body-referenced mechanism, was employed to incorporate the effects of adaptation. Connections between VPEL adaptation and other cases of perceptual adaptation of visual direction are described.
Migliaccio, Americo A; Della Santina, Charles C; Carey, John P; Minor, Lloyd B; Zee, David S
2006-08-01
We examined how the gain of the torsional vestibulo-ocular reflex (VOR) (defined as the instantaneous eye velocity divided by inverted head velocity) in normal humans is affected by eye position, target distance, and the plane of head rotation. In six normal subjects we measured three-dimensional (3D) eye and head rotation axes using scleral search coils, and 6D head position using a magnetic angular and linear position measurement device, during low-amplitude (approximately 20 degrees ), high-velocity (approximately 200 degrees/s), high-acceleration (approximately 4000 degrees /s2) rapid head rotations or 'impulses.' Head impulses were imposed manually and delivered in five planes: yaw (horizontal canal plane), pitch, roll, left anterior-right posterior canal plane (LARP), and right anterior-left posterior canal plane (RALP). Subjects were instructed to fix on one of six targets at eye level. Targets were either straight-ahead, 20 degrees left or 20 degrees right from midline, at distance 15 or 124 cm from the subject. Two subjects also looked at more eccentric targets, 30 degrees left or 30 degrees right from midline. We found that the vertical and horizontal VOR gains increased with the proximity of the target to the subject. Previous studies suggest that the torsional VOR gain should decrease with target proximity. We found, however, that the torsional VOR gain did not change for all planes of head rotation and for both target distances. We also found a dynamic misalignment of the vertical positions of the eyes during the torsional VOR, which was greatest during near viewing with symmetric convergence. This dynamic vertical skew during the torsional VOR arises, in part, because when the eyes are converged, the optical axes are not parallel to the naso-occipital axes around which the eyes are rotating. In five of six subjects, the average skew ranged 0.9 degrees -2.9 degrees and was reduced to <0.4 degrees by a 'torsional' quick-phase (around the naso-occipital axis) occurring <110 ms after the onset of the impulse. We propose that the torsional quick-phase mechanism during the torsional VOR could serve at least three functions: (1) resetting the retinal meridians closer to their usual orientation in the head, (2) correcting for the 'skew' deviation created by misalignment between the axes around which the eyes are rotating and the line of sight, and (3) taking the eyes back toward Listing's plane.
Optic Neuropathy Secondary to Polyarteritis Nodosa, Case Report, and Diagnostic Challenges.
Vazquez-Romo, Kristian A; Rodriguez-Hernandez, Adrian; Paczka, Jose A; Nuño-Suarez, Moises A; Rocha-Muñoz, Alberto D; Zavala-Cerna, Maria G
2017-01-01
To describe a case of optic neuropathy as a primary manifestation of polyarteritis nodosa (PAN) and discuss diagnostic challenges. Case report. A 41-year-old Hispanic man presented with a 2-day history of reduced visual acuity in his left eye. Physical examination revealed a complete visual field loss in the affected eye. Best-corrected visual acuity (BCVA) in the left eye was hand motion, and fundus examination revealed a hyperemic optic disk with blurred margins, swelling, retinal folds, dilated veins, and normal size arteries. BCVA in the right eye was 20/20; no anomalies were seen during examination of the fundus. The patient was started on oral corticosteroids and once the diagnosis of PAN was made, cyclophosphamide was added to the treatment regimen. Six months later, the patient recovered his BCVA to 20/20 in his left eye. Rarely does optic neuropathy present as a primary manifestation of PAN; nevertheless, it represents an ophthalmologic emergency that requires expeditious anti-inflammatory and immunosuppressive treatment to decrease the probability of permanent visual damage. Unfortunately, diagnosing PAN is challenging as it necessitates a high index of suspicion. In young male patients who present for the first time with diminished visual acuity, ophthalmologists become cornerstones in the suspicion of this diagnosis and should be responsible for continuing the study until a diagnosis is reached to ensure rapid commencement of immunosuppressive treatment.
Sitompul, Ratna; Kusumowidagdo, Gladys; Matiur, Eiko B.; Barliana, Julie D.; Sitorus, Rita S.; Sungkar, Saleha
2018-01-01
Ocular trauma occurring in children often leads to visual impairment or blindness when it is not properly managed. This often occurs in underdeveloped regions with difficult access to professional care at local health facilities. We report a case of post-trauma corneal staphyloma in an underdeveloped region of eastern Indonesia to illustrate the importance of proper management of ocular trauma in areas lacking such expertise and where patients have difficulty accessing even basic health care. During a community health outreach in Southwest Sumba, eastern Indonesia in May 2017, a 7-year-old boy presented with white protrusion of the left eye of 3 years' duration following an event of sharp trauma. The patient lived in an inaccessible and impoverished area. Upon contemporary examination, visual acuity of the left eye was 1/300 while that of the right eye was 6/6. Anterior examination revealed corneal staphyloma of the left eye, and its posterior segment could not be evaluated. The patient was transported to an eye care center in Jakarta, receiving a stock prosthesis implant while awaiting a corneal evisceration procedure with dermofat graft. Ocular trauma is one of the most common causes of visual impairment in children. This case illustrates the consequences of inadequate post-trauma management and the importance of prevention of infection. PMID:29681830
Hippo in Super Resolution from Super Panorama
1998-07-03
This view of the "Hippo," 25 meters to the west of the lander, was produced by combining the "Super Panorama" frames from the IMP camera. Super resolution was applied to help to address questions about the texture of this rock and what it might tell us about its mode of origin. The composite color frames that make up this anaglyph were produced for both the right and left eye of the IMP. These composites consist of more than 15 frames per eye (because multiple sequences covered the same area), taken with different color filters that were enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution panchromatic frame that is sharper than an individual frame would be. These panchromatic frames were then colorized with the red, green, and blue filtered images from the same sequence. The color balance was adjusted to approximate the true color of Mars. The anaglyph view was produced by combining the left with the right eye color composite frames by assigning the left eye composite view to the red color plane and the right eye composite view to the green and blue color planes (cyan), to produce a stereo anaglyph mosaic. This mosaic can be viewed in 3-D on your computer monitor or in color print form by wearing red-blue 3-D glasses. http://photojournal.jpl.nasa.gov/catalog/PIA01421
Long-term control of CMV retinitis in a patient with idiopathic CD4+ T lymphocytopenia.
Yashiro, Shigeko; Fujino, Yujiro; Tachikawa, Natsuo; Inamochi, Kazuya; Oka, Shinichi
2013-04-01
Cytomegalovirus (CMV) retinitis with idiopathic CD4(+) T lymphocytopenia (ICL) is rare and difficult to control. We report a first case for long-term control of CMV retinitis with ICL using interleukin-2 (IL-2) therapy and succeeded in discontinuation of anti-CMV therapy. A 49-year-old Japanese woman was diagnosed with ICL based on low CD4(+) count (72/μl), negative for HIV-1 and -2 antibodies, and absence of any defined immunodeficiency diseases or immunosuppressive therapy. PCR test of the aqueous humor in the right eye was suggestive of CMV retinitis. She was treated with systemic ganciclovir, but after several relapses of CMV retinitis, rhegmatogenous retinal detachment appeared in the right eye and she became blind in that eye. Three years later, she developed CMV retinitis in the left eye. Although she received systemic and focal anti-CMV treatments, the retinitis showed no improvement. Finally, retinal detachment occurred, and she underwent vitrectomy. IL-2 was injected to increase CD4(+) counts. Because of hyperpyrexia, blepharedema, central scotoma, and color anomaly, we changed to low-dose IL-2 therapy with no side effects. Finally, we succeeded in increasing the CD4(+) count to more than 200/μl after discontinuation of low-dose IL-2 therapy. CMV retinitis never recurred after discontinuation of anti-CMV therapy, with good visual acuity of 20/20 in the left eye. She developed blindness of the first affected right eye, whereas the visual acuity of the left eye remains excellent more than 12 years after the onset of CMV retinitis through the combined use of anti-CMV therapy, IL-2 therapy, and vitrectomy.
de Latude, Marion; Demange, Marianne; Bec, Philippe; Blois-Heulin, Catherine
2009-01-01
Hemispheric asymmetry in emotional perception has been put forward by different theories as the right hemisphere theory or the valence theory. But no consensus was found about the role played by both hemispheres. So, in order to test the different theories, we investigated preferential use of one eye in red-capped mangabeys, at the individual as well as at the group level. In this study we investigated the influence of the emotional value of stimuli on the direction and strength of visual preference of 14 red-capped mangabeys. Temporal stability of the bias of use of a given eye was evaluated by comparing our current results to those obtained 2.5 months previously. Two experimental devices, a tube and a box, tested five different stimuli: four food types varying in palatability and a neutral stimulus. The subjects' food preferences were evaluated before testing the laterality. The mangabeys used their left eyes predominantly at the group level for the tube task. The majority of the subjects showed a visual preference at the individual level for the box task, but this bias was not present at the group level. As the palatability of the stimuli increased, the number of lateralized subjects and the number of subjects using preferentially their left eye increased. Similarly, the strength of laterality was related to food preference. Strength of laterality was significantly higher for subjects using their left eye than for subjects using their right eye. Preferential use of a given eye was stable over short periods 2.5 months later. Our data agree with reports on visual laterality for other species. Our results support the valence theory of a hemispheric sharing of control of emotions in relation to their emotional value.
Laser in situ keratomileusis for residual hyperopic astigmatism after conductive keratoplasty.
Kymionis, George D; Aslanides, Ioannis M; Khoury, Aghlab N; Markomanolakis, Marinos M; Naoumidi, Tatiana; Pallikaris, loannis G
2004-01-01
To report a case of laser in situ keratomileusis (LASIK) in a patient with previous conductive keratoplasty. A 48-year-old man underwent conductive keratoplasty for low hyperopic astigmatism (manifest refraction OD: +2.25 -0.50 x 77 degrees; OS: +2.50 -0.50 x 105 degrees). Three months postoperatively, UCVA was 20/25 and BSCVA was 20/20 in both eyes; manifest refraction OD: -0.25 -0.75 x 110 degrees; OS: +0.75 -0.75 x 50 degrees. Sixteen months after the operation, regression of refractive outcome was (manifest) OD: +1.75 -1.25 x 90 degrees; OS: +2.50 -0.50 x 85 degrees; UCVA was 20/40 in the right eye and 20/63 in the left eye and BSCVA was 20/20 in both eyes. LASIK was performed for hyperopic regression in the left eye using an automated microkeratome (Alcon SKBM, 130-microm plate; Aesculap-Meditec MEL 70 excimer laser). LASIK was uneventful and no intraoperative or postoperative complications related to the previous conductive keratoplasty procedure or LASIK were observed. Three months after LASIK and 19 months after the initial conductive keratoplasty, the patient's left eye was emmetropic; UCVA was 20/20(-2), BSCVA was 20/20 and manifest refraction was +0.25 -0.25 x 35 degrees. There was a uniform increase in topographical steepening. Visual acuity, refraction and topographic findings remained unchanged at 6 months. Even though our experience is limited, treatment of hyperopia with LASIK in an eye with refractive regression following previous conductive keratoplasty resulted in a predicted refractive outcome, with no complications, and improvement in visual acuity at 6 months follow-up.
Orbital tuberculosis in childhood with intracranial extension: a case report.
Tuli, Navneet
2010-01-28
The common causes of orbital masses in pediatric age group include pseudotumour, lymphomas, hemangioma and dermoid cyst. Orbital tuberculosis is rare especially in children. We report a case of 5 year old child who presented with proptosis and gross diminution of vision due to orbital tuberculoma. Ocular examination of the left eye revealed proptosis with the eyeball displaced downwards and forwards. Vision was counting finger close to face. CT Scan showed an extraconal soft tissue mass along posteromedial side of left orbit with lateral displacement of medial rectus muscle. On antitubercular treatment, proptosis regressed and visual recovery was observed over a period of six month vision, in the left eye at the last followup was 20/30.
Barnacle Bill in Super Resolution from Super Panorama
1998-07-03
"Barnacle Bill" is a small rock immediately west-northwest of the Mars Pathfinder lander and was the first rock visited by the Sojourner Rover's alpha proton X-ray spectrometer (APXS) instrument. This image shows super resolution techniques applied to the first APXS target rock, which was never imaged with the rover's forward cameras. Super resolution was applied to help to address questions about the texture of this rock and what it might tell us about its mode of origin. This view of Barnacle Bill was produced by combining the "Super Panorama" frames from the IMP camera. Super resolution was applied to help to address questions about the texture of these rocks and what it might tell us about their mode of origin. The composite color frames that make up this anaglyph were produced for both the right and left eye of the IMP. The composites consist of 7 frames in the right eye and 8 frames in the left eye, taken with different color filters that were enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution panchromatic frame that is sharper than an individual frame would be. These panchromatic frames were then colorized with the red, green, and blue filtered images from the same sequence. The color balance was adjusted to approximate the true color of Mars. The anaglyph view was produced by combining the left with the right eye color composite frames by assigning the left eye composite view to the red color plane and the right eye composite view to the green and blue color planes (cyan), to produce a stereo anaglyph mosaic. This mosaic can be viewed in 3-D on your computer monitor or in color print form by wearing red-blue 3-D glasses. http://photojournal.jpl.nasa.gov/catalog/PIA01409
Yeşilyaprak, Sevgi Sevi; Yıldırım, Meriç Şenduran; Tomruk, Murat; Ertekin, Özge; Algun, Z Candan
2016-01-01
There is limited information on effective balance training techniques including virtual reality (VR)-based balance exercises in residential settings and no studies have been designed to compare the effects of VR-based balance exercises with conventional balance exercises in older adults living in nursing homes in Turkey. The objective of our study was to investigate the effects of VR-based balance exercises on balance and fall risk in comparison to conventional balance exercises in older adults living in nursing homes. A total sample of 18 subjects (65-82 years of age) with fall history who were randomly assigned to either the VR group (Group 1, n = 7) or the conventional exercise group (Group 2, n = 11) completed the exercise training. In both groups, Berg balance score (BBS), timed up & go duration, and left leg stance and tandem stance duration with eyes closed significantly improved with time (p < 0.05), but changes were similar in both groups (p > 0.05) after training, indicating that neither the exercise method was superior. Similar improvements were found in balance and fall risk with VR-based balance training and conventional balance training in older adults living in the nursing home. Both exercise trainings can be preferable by health care professionals considering fall prevention. Appropriate patient selection is essential.
ERIC Educational Resources Information Center
Balajthy, Ernest P., Jr.
Sixty tenth graders participated in this study of relationships between eye/voice span, phrase and clause boundaries, reading ability, and sentence structure. Results indicated that sentences apparently are "chunked" into surface constituents during processing. Better tenth grade readers had longer eye/voice spans than did poorer readers and…
77 FR 41879 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-16
... to a traumatic injury sustained in 1994. The best corrected visual acuity in his right eye is 20/60.... Rubeck, 65, has complete loss of vision in his left eye due to a traumatic accident sustained during... CMV. Scott C. Westphal Mr. Westphal, 31, has macular scarring in his right eye due to a traumatic...
77 FR 27847 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... vision in his right eye due to a traumatic injury sustained at age 14. The best corrected visual acuity... CMV. John C. Smith Mr. Smith, 54, has a prosthetic right eye due to a traumatic injury sustained in... CMV. John F. Lynch Mr. Lynch, 35, has complete loss of vision in his left eye due to a traumatic...
75 FR 14656 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... traumatic injury sustained during childhood. The best corrected visual acuity in his right eye is 20/20... moving violations in a CMV. Lane L. Savoie Mr. Savoie, 57, has a prosthetic left eye due to a traumatic injury sustained in 1995. The best corrected visual acuity in his right eye is 20/20. Following an...
Along Endurance Crater's Inner Wall (Left Eye)
NASA Technical Reports Server (NTRS)
2004-01-01
This view from the base of 'Burns Cliff' in the inner wall of 'Endurance Crater' combines several frames taken by Opportunity's navigation camera during the NASA rover's 280th martian day (Nov. 6, 2004). It is the left-eye member of a stereo pair, presented in a cylindrical-perspective projection with geometric seam correction. The cliff dominates the left and right portions of the image, while the central portion looks down into the crater. The 'U' shape of this mosaic results from the rover's tilt of about 30 degrees on the sloped ground below the cliff. Rover wheel tracks in the left half of the image show some of the slippage the rover experienced in making its way to this point. The site from which this image was taken has been designated as Opportunity's Site 37.Combined Brown syndrome and superior oblique palsy without a trochlear nerve: case report.
Yang, Hee Kyung; Kim, Jae Hyoung; Kim, Ji-Soo; Hwang, Jeong-Min
2017-08-25
Congenital Brown syndrome is characterized by limited elevation particularly during adduction. The pathogenesis of congenital Brown syndrome is still controversial. A 6-year-old boy had been tilting his head to the left since infancy. He showed right hypertropia (RHT) of 2 prism diopters (Δ) in the primary position. He showed RHT 6Δ in right gaze, RHT 2Δ in left gaze, RHT 12Δ in right head tilt, and orthotropia in left head tilt. The right eye showed limitation of elevation and depression on adduction, and the left eye showed overdepression on adduction. MR images showed an absent right trochlear nerve with a hypoplastic ipsilateral superior oblique muscle. Congenital Brown syndrome may be associated with an absent trochlear nerve and hypoplastic superior oblique muscle suggesting an etiologic mechanism of congenital cranial dysinnervation disorder.
Orlosky, Jason; Itoh, Yuta; Ranchet, Maud; Kiyokawa, Kiyoshi; Morgan, John; Devos, Hannes
2017-04-01
For neurodegenerative conditions like Parkinson's disease, early and accurate diagnosis is still a difficult task. Evaluations can be time consuming, patients must often travel to metropolitan areas or different cities to see experts, and misdiagnosis can result in improper treatment. To date, only a handful of assistive or remote methods exist to help physicians evaluate patients with suspected neurological disease in a convenient and consistent way. In this paper, we present a low-cost VR interface designed to support evaluation and diagnosis of neurodegenerative disease and test its use in a clinical setting. Using a commercially available VR display with an infrared camera integrated into the lens, we have constructed a 3D virtual environment designed to emulate common tasks used to evaluate patients, such as fixating on a point, conducting smooth pursuit of an object, or executing saccades. These virtual tasks are designed to elicit eye movements commonly associated with neurodegenerative disease, such as abnormal saccades, square wave jerks, and ocular tremor. Next, we conducted experiments with 9 patients with a diagnosis of Parkinson's disease and 7 healthy controls to test the system's potential to emulate tasks for clinical diagnosis. We then applied eye tracking algorithms and image enhancement to the eye recordings taken during the experiment and conducted a short follow-up study with two physicians for evaluation. Results showed that our VR interface was able to elicit five common types of movements usable for evaluation, physicians were able to confirm three out of four abnormalities, and visualizations were rated as potentially useful for diagnosis.
NASA Technical Reports Server (NTRS)
Harm, D. L.; Taylor, L. C.; Bloomberg, J. J.
2007-01-01
Virtual environments offer unique training opportunities, particularly for training astronauts and preadapting them to the novel sensory conditions of microgravity. Two unresolved human factors issues in virtual reality (VR) systems are: 1) potential "cybersickness", and 2) maladaptive sensorimotor performance following exposure to VR systems. Interestingly, these aftereffects are often quite similar to adaptive sensorimotor responses observed in astronauts during and/or following space flight. Initial interpretation of novel sensory information may be inappropriate and result in perceptual errors. Active exploratory behavior in a new environment, with resulting feedback and the formation of new associations between sensory inputs and response outputs, promotes appropriate perception and motor control in the new environment. Thus, people adapt to consistent, sustained alterations of sensory input such as those produced by microgravity, unilateral labyrinthectomy and experimentally produced stimulus rearrangements. The purpose of this research was to compare disturbances in sensorimotor coordination produced by dome and head-mounted virtual environment displays and to examine the effects of exposure duration, and repeated exposures to VR systems. The first study examined disturbances in balance control, and the second study examined disturbances in eye-head-hand (EHH) and eye-head coordination.
Iris metastasis of gastric adenocarcinoma.
Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah
2016-03-08
Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.
Bilateral ophthalmic artery occlusion in rhino-orbito-cerebral mucormycosis.
Song, Yoo Mi; Shin, Sun Young
2008-03-01
To report a case of bilateral ophthalmic artery occlusion in rhino-orbito-cerebral mucormycosis. Reviewed clinical charts, photographs, and fluorescein angiography An 89-year-old man with poorly controlled diabetes developed sudden bilateral ptosis, complete ophthalmoplegia of the right eye, and superior rectus palsy of the left eye. Brain and orbit magnetic resonance imaging showed midbrain infarction and mild diffuse sinusitis. On the 2nd day of hospitalization, sudden visual loss and light reflex loss developed. There were retinal whitening, absence of retinal arterial filling, and a total lack of choroidal perfusion on fluorescein angiography of the right eye. The left eye showed a cherry red spot in the retina and the absence of retinal arterial filling and partial choroidal perfusion on fluorescein angiography. On rhinologic examination, mucormyosis was noticed. Despite treatment, visual acuity and light reflex did not recover and he died 4 days after admission. Bilateral ophthalmic artery occlusion can occur in rhino-orbital-cerebral mucormycosis.
[Persistence of the primordial vitreous body and buphthalmos].
Cernea, P; Simionescu, C; Bosun, I
1995-01-01
Persistence of the hyperplasic primordial vitreous body is determined by a deletion of embryonal development of the vitreous body and of the hyaloid vascular system. Infant aged 3.5 years presents persistence of primordial vitreous body with crystalline dislocation in the camera aquosa and secondary buphthalmos of the left eye and microphthalmos with dislocation of the crystalline in the vitreous body of the right eye. At the back of the right eye we noticed a whitish mass, richly vascularized with vestiges from the hyaloid artery, but the posterior half of the vitreous cavity is filled with microscopic blood; the fibrovascular membrane is made of conjunctive tissue set in parallel layers and vessels with macrolipophagic degeneration. Microscopic investigation of retina reveals glial hyperplasia zones in the neighbourhood of the vitreous body. In the present paper the authors show the persistence of the primordial vitreous body in the left eye and bilateral dislocation of the crystalline, revealing multiple ocular malformations.
Macular hole in juvenile X-linked retinoschisis.
Al-Swaina, Nayef; Nowilaty, Sawsan R
2013-10-01
An 18 year-old male with no antecedent of trauma, systemic syndrome or myopia was referred for surgical treatment of a full thickness macular hole in the left eye. A more careful inspection revealed discrete foveal cystic changes in the fellow eye and subtle peripheral depigmented retinal pigment epithelial changes in both eyes. A spectral-domain optical coherence tomography (SD-OCT) scan confirmed, in addition to the full thickness macular hole in the left eye, microcystic spaces in the nuclear layers of both retinae. The diagnosis of X-linked retinoschisis was confirmed with a full field electroretinogram displaying the typical negative ERG. Macular holes are uncommon in the young and those complicating X-linked retinoschisis are rare. This report highlights the importance of investigating the presence of a macular hole in a young patient and illustrates the clinical and SD-OCT clues beyond the foveal center which led to the correct diagnosis of X-linked juvenile retinoschisis.
Barnacle Bill in Super Resolution from Insurance Panorama
NASA Technical Reports Server (NTRS)
1998-01-01
Barnacle Bill is a small rock immediately west-northwest of the Mars Pathfinder lander and was the first rock visited by the Sojourner Rover's alpha proton X-ray spectrometer (APXS) instrument. This image shows super resolution techniques applied to the first APXS target rock, which was never imaged with the rover's forward cameras. Super resolution was applied to help to address questions about the texture of this rock and what it might tell us about its mode of origin.
This view of Barnacle Bill was produced by combining the 'Insurance Pan' frames taken while the IMP camera was still in its stowed position on sol2. The composite color frames that make up this anaglyph were produced for both the right and left eye of the IMP. The right eye composite consists of 5 frames, taken with different color filters, the left eye consists of only 1 frame. The resultant image from each eye was enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution panchromatic frame that is sharper than an individual frame would be. These panchromatic frames were then colorized with the red, green, and blue filtered images from the same sequence. The color balance was adjusted to approximate the true color of Mars.The anaglyph view was produced by combining the left with the right eye color composite frames by assigning the left eye composite view to the red color plane and the right eye composite view to the green and blue color planes (cyan), to produce a stereo anaglyph mosaic. This mosaic can be viewed in 3-D on your computer monitor or in color print form by wearing red-blue 3-D glasses.Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. Barnacle Bill is a small rock immediately west-northwest of the Mars Pathfinder lander and was the first rock visited by the Sojourner Rover's alpha proton X-ray spectrometer (APXS) instrument.Intermediate view synthesis for eye-gazing
NASA Astrophysics Data System (ADS)
Baek, Eu-Ttuem; Ho, Yo-Sung
2015-01-01
Nonverbal communication, also known as body language, is an important form of communication. Nonverbal behaviors such as posture, eye contact, and gestures send strong messages. In regard to nonverbal communication, eye contact is one of the most important forms that an individual can use. However, lack of eye contact occurs when we use video conferencing system. The disparity between locations of the eyes and a camera gets in the way of eye contact. The lock of eye gazing can give unapproachable and unpleasant feeling. In this paper, we proposed an eye gazing correction for video conferencing. We use two cameras installed at the top and the bottom of the television. The captured two images are rendered with 2D warping at virtual position. We implement view morphing to the detected face, and synthesize the face and the warped image. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.
Notice and Credits Page - NOAA's National Weather Service
- Visolve is a software application (free for personal use) that transforms colors of the computer display Mac OS X 10.2 or later. (Purchase) - A 30-day free trial of eyePilot is available from eyePilot web site - http://www.colorhelper.com/ Java Java Virtual Machine - free download from java.com Adobe Reader
Virtual reality implementation in neurosurgical practice: the "can't take my eyes off you" effect.
Matis, Georgios K; Silva, Danilo O de A; Chrysou, Olga I; Karanikas, Michail; Pelidou, Sygkliti-Henrietta; Birbilis, Theodossios A; Bernardo, Antonio; Stieg, Philip
2013-01-01
During the last few years, virtual reality (VR) has been increasingly implemented in the neurosurgical practice. The scope of this paper is to briefly outline the educational role of this novel technology in training surgeons. At the same time, the ability of VR workstations such as the Dextroscope® to consistently simulate the surgical trajectory to the lesion-target is highlighted. The authors shed light to the current applications of VR systems in the neurosurgical field by describing not only the advantages of those systems, but their principal drawbacks as well. It seems that VR has come to stay and it is already the new best friend of residents due to its "Can't take my eyes off you effect".
Bobbo, Daniela; Vallortigara, Giorgio; Mascetti, Gian Gastone
2006-06-03
The pattern of monocular/unihemispheric sleep (Mo-Un sleep) was studied behaviourally in male and female chicks after early post-hatching changes of the imprinting object. Chicks were reared with an imprinting object on day 1 post-hatching which was removed or changed on day 2. On day 1, time spent in binocular sleep (both eyes closed) was similar in male and female chicks, though the number of episodes was lower in females than in males. There was no eye-closure bias in the pattern of Mo-Un sleep (one eye shut and the other open) in chicks of both sexes. On day 2, chicks subjected to the removal of imprinting object showed less time and number of episodes of binocular sleep than control chicks and chicks subjected to changes of imprinting object. There was no eye-closure bias in control chicks whilst a significant bias for more right Mo-Un sleep was recorded in chicks after removal and changes of imprinting object of both sexes. It is suggested that the removal or changes of imprinting object would cause a decrease of binocular sleep and trigger processes associated to secondary imprinting involving the left hemisphere. The bias for more right Mo-Un sleep (right eye-closure) could be the by-product of consolidation processes of secondary imprinting memories in the left hemisphere and/or of more left eye-opening as a result of periodical awakening of right hemisphere to control the environment after a stressful condition such as the removal or change of imprinting object.
Comparison of macular OCTs in right and left eyes of normal people
NASA Astrophysics Data System (ADS)
Mahmudi, Tahereh; Kafieh, Rahele; Rabbani, Hossein; Mehri dehnavi, Alireza; Akhlagi, Mohammadreza
2014-03-01
Retinal 3D Optical coherence tomography (OCT) is a non-invasive imaging modality in ocular diseases. Due to large volumes of OCT data, it is better to utilize automatic extraction of information from OCT images, such as total retinal thickness and retinal nerve fiber layer thickness (RNFLT). These two thickness values have become useful indices to indicate the progress of diseases like glaucoma, according to the asymmetry between two eyes of an individual. Furthermore, the loss of ganglion cells may not be diagnosable by other tests and even not be evaluated when we only consider the thickness of one eye (due to dramatic different thickness among individuals). This can justify our need to have a comparison between thicknesses of two eyes in symmetricity. Therefore, we have proposed an asymmetry analysis of the retinal nerve layer thickness and total retinal thickness around the macula in the normal Iranian population. In the first step retinal borders are segmented by diffusion map method and thickness profiles were made. Then we found the middle point of the macula by pattern matching scheme. RNFLT and retinal thickness are analyzed in 9 sectors and the mean and standard deviation of each sector in the right and left eye are obtained. The maximums of the average RNFL thickness in right and left eyes are seen in the perifoveal nasal, and the minimums are seen in the fovea. Tolerance limits in RNFL thickness is shown to be between 0.78 to 2.4 μm for 19 volunteers used in this study.
Development and application of virtual reality for man/systems integration
NASA Technical Reports Server (NTRS)
Brown, Marcus
1991-01-01
While the graphical presentation of computer models signified a quantum leap over presentations limited to text and numbers, it still has the problem of presenting an interface barrier between the human user and the computer model. The user must learn a command language in order to orient themselves in the model. For example, to move left from the current viewpoint of the model, they might be required to type 'LEFT' at a keyboard. This command is fairly intuitive, but if the viewpoint moves far enough that there are no visual cues overlapping with the first view, the user does not know if the viewpoint has moved inches, feet, or miles to the left, or perhaps remained in the same position, but rotated to the left. Until the user becomes quite familiar with the interface language of the computer model presentation, they will be proned to lossing their bearings frequently. Even a highly skilled user will occasionally get lost in the model. A new approach to presenting type type of information is to directly interpret the user's body motions as the input language for determining what view to present. When the user's head turns 45 degrees to the left, the viewpoint should be rotated 45 degrees to the left. Since the head moves through several intermediate angles between the original view and the final one, several intermediate views should be presented, providing the user with a sense of continuity between the original view and the final one. Since the primary way a human physically interacts with their environment should monitor the movements of the user's hands and alter objects in the virtual model in a way consistent with the way an actual object would move when manipulated using the same hand movements. Since this approach to the man-computer interface closely models the same type of interface that humans have with the physical world, this type of interface is often called virtual reality, and the model is referred to as a virtual world. The task of this summer fellowship was to set up a virtual reality system at MSFC and begin applying it to some of the questions which concern scientists and engineers involved in space flight. A brief discussion of this work is presented.
Treatment of Phthiriasis Palpebrarum and Crab Louse: Petrolatum Jelly and 1% Permethrin Shampoo.
Karabela, Yunus; Yardimci, Gurkan; Yildirim, Isik; Atalay, Eray; Karabela, Semsi Nur
2015-01-01
Phthiriasis palpebrarum is an uncommon cause of blepharoconjunctivitis in which Pthirus pubis infest the eyelashes. We report a case of unilateral phthiriasis palpebrarum with crab louse. A 45-year-old man presented with conjunctival hyperaemia and moderate itching associated with irritation, and crusty excretions of the eyelashes in the left eye. Careful slit-lamp examination revealed many lice and nits in left eye and mild conjunctival hyperaemia. No abnormality was found in the right eye. On dermatologic examination, only one louse was found at the pubic area. The patient was treated effectively with petrolatum jelly (Vaseline) and 1% permethrin shampoo (Kwellada 1% shampoo). At the end of the first week no louse or nit was present on eyelashes and pubic area.
Vallortigara, G; Andrew, R J
1994-12-01
Right hemisphere advantage in individual recognition (as shown by differences between response to strangers and companions) is clear in the domestic chick. Chicks using the left eye (and so, thanks to the complete optic decussation, predominantly the right hemisphere) discriminate between stranger and companion. Chicks using the right eye discriminate less clearly or not at all. The ability of left eyed chicks to respond to differences between strangers and companions stimuli is associated with a more general ability to detect and respond to novelty: this difference between left and right eyed chicks also holds for stimuli which are not social partners. The right hemisphere also shows advantage in tasks with a spatial component (topographical learning; response to change in the spatial context of a stimulus) in the chick, as in humans. Similar specialisations of the two hemispheres are also revealed in tests which involve olfactory cues presented by social partners. The special properties of the left hemisphere are less well established in the chick. Evidence reviewed here suggests that it tends to respond to selected properties of a stimulus and to use them to assign it to a category; such assignment then allows an appropriate response. When exposed to an imprinting stimulus (visual or auditory) a chick begins by using right eye or ear (suggesting left hemisphere control), and then shifts to the left eye or ear (suggesting right hemisphere control), as exposure continues. The left hemisphere here is thus involved whilst behaviour is dominated by vigorous response to releasing stimuli presented by an object. Subsequent learning about the full detailed properties of the stimulus, which is crucial for individual recognition, may explain the shift to right hemisphere control after prolonged exposure to the social stimulus. There is a marked sex difference in choice tests: females tend to choose companions in tests where males choose strangers. It is possible that this difference is specifically caused by stronger motivation to sustain social contact in female chicks, for which there is extensive evidence. However, sex differences in response to change in familiar stimuli are also marked in tests which do not involve social partners. Finally, in both sexes there are two periods during development in which there age-dependent shifts in bias to use one or other hemisphere. These periods (days 3-5 and 8-11) coincide with two major changes in the social behaviour of chicks reared by a hen in a normal brood. It is argued that one function of these periods is to bring fully into play the hemisphere most appropriate to the type of response to, and learning about, social partners which is needed at particular points in development. Parallels are discussed between the involvement of lateralised processes in the recognition of social partners in chicks and humans. Copyright © 1994. Published by Elsevier B.V.
Transcutaneous periorbital electrical stimulation in the treatment of dry eye.
Pedrotti, Emilio; Bosello, Francesca; Fasolo, Adriano; Frigo, Anna C; Marchesoni, Ivan; Ruggeri, Alfredo; Marchini, Giorgio
2017-06-01
To evaluate efficacy and safety of transcutaneous application of electrical current on symptoms and clinical signs of dry eye (DE). 27 patients with DE underwent transcutaneous electrostimulation with electrodes placed onto the periorbital region of both eyes and manual stimulation with a hand-piece conductor moved by the operator. Each patient underwent 12 sessions of 22 min spread over 2 months, two sessions per week in the first month and one session per week in the second month. Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), fluorescein staining of the cornea, Schirmer I test and adverse events were evaluated at baseline, at end of treatment and at 6 and 12 months. OSDI improved from 43.0±19.2 at baseline to 25.3±22.1 at end of treatment (mean±SD, p=0.001). These effects were substantially maintained at 6-month and 12-month follow-up evaluations. Improvement of the values of TBUT was recorded for the right eye at the end of treatment (p=0.003) and found in the left eye after 12 months (p=0.02). The Oxford scores changed in both eyes at the end of treatment and at the 6-month evaluation (p<0.001), and in the right eye at the 12-month evaluation (p=0.035). Schirmer I improved significantly at the end of treatment in the left eye (p=0.001) and in both eyes at the 12-month evaluation (p=0.004 and p=0.039 for the left and right eye, respectively). A significant reduction of the use of tear substitutes was found at the end of treatment (p=0.003), and was maintained during the follow-up (p<0.001).No complications occurred and patients found the treatment satisfying. Transcutaneous electrical stimulation was shown to improve DE, both subjectively and objectively, without any adverse effects and has the potential to enlarge the armamentarium for treating DE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
NASA Astrophysics Data System (ADS)
Moore, C. A.; Gertman, V.; Olsoy, P.; Mitchell, J.; Glenn, N. F.; Joshi, A.; Norpchen, D.; Shrestha, R.; Pernice, M.; Spaete, L.; Grover, S.; Whiting, E.; Lee, R.
2011-12-01
Immersive virtual reality environments such as the IQ-Station or CAVE° (Cave Automated Virtual Environment) offer new and exciting ways to visualize and explore scientific data and are powerful research and educational tools. Combining remote sensing data from a range of sensor platforms in immersive 3D environments can enhance the spectral, textural, spatial, and temporal attributes of the data, which enables scientists to interact and analyze the data in ways never before possible. Visualization and analysis of large remote sensing datasets in immersive environments requires software customization for integrating LiDAR point cloud data with hyperspectral raster imagery, the generation of quantitative tools for multidimensional analysis, and the development of methods to capture 3D visualizations for stereographic playback. This study uses hyperspectral and LiDAR data acquired over the China Hat geologic study area near Soda Springs, Idaho, USA. The data are fused into a 3D image cube for interactive data exploration and several methods of recording and playback are investigated that include: 1) creating and implementing a Virtual Reality User Interface (VRUI) patch configuration file to enable recording and playback of VRUI interactive sessions within the CAVE and 2) using the LiDAR and hyperspectral remote sensing data and GIS data to create an ArcScene 3D animated flyover, where left- and right-eye visuals are captured from two independent monitors for playback in a stereoscopic player. These visualizations can be used as outreach tools to demonstrate how integrated data and geotechnology techniques can help scientists see, explore, and more adequately comprehend scientific phenomena, both real and abstract.
Roberts, D K; Winters, J E; Castells, D D; Clark, C A; Teitelbaum, B A
2001-01-01
To investigate pigmented striae of the anterior lens capsule in African-Americans, a potential indicator of significant anterior segment pigment dispersion. A group of 40 African-American subjects who exhibited pigmented lens striae (PLS) were identified from a non-referred, primary eye care population in Chicago, IL, USA. These subjects were then compared to an age, race, and gender matched control group relative to refractive error and the presence or absence of diabetes and hypertension. The PLS subjects (mean age = 65.4 +/- 8.8 years, range = 50-87 years) consisted of 36 females and 4 males. PLS were bilateral in 36 (85%) of the 40 subjects. Among the eyes with PLS, 21 (55%) of 38 right eyes and 22 (61%) of 36 left eyes also had significant corneal endothelial pigment dusting, commonly in the shape of a Krukenberg's spindle. Ten (25%) of the PLS subjects had either glaucoma or ocular hypertension (7 bilateral, 3 unilateral). The presence of trabecular meshwork pigment varied from minimal to heavy. The mean +/- SD (range) refractive error of the PLS right eyes was +1.61 +/- 1.43D (-1.50 to +5.00D) and +1.77 +/- 1.37D (-1.00 to +5.00D) for the left eyes. Based on these data, the PLS right eyes were +1.63D (Student's t, p = 0.0001; 95% CI = +0.82 to +2.44D) more hyperopic on average than the control right eyes, and the PLS left eyes were +1.77D (p = 0.0001; 95% CI = +0.92 to +2.63D) more hyperopic on average than the control left eyes. Trend analysis showed a gradually increasing likelihood of PLS with increasing magnitude of hyperopia in both eyes (Mantel-Haenszel chi-square, p = 0.001). Among PLS subjects, 24 (60%) of 40 were hypertensive and 9 (23%) of 40 were diabetic. However, these proportions were not significantly different (two-tailed Fisher's exact test; hypertension: p = 0.30; diabetes: p = 0.70) from the randomly selected controls. Among our African-American group, which consisted predominately of females >50 years of age, the likelihood of PLS increased with increasing hyperopic refractive error. This finding is consistent with the possibility that PLS may, in some circumstances, indicate a significant pigment dispersal process due to iris-lens rubbing that may be associated with crowding of anterior segment structures. Additional study is warranted to further assess the nature of PLS, their precise relationship with an age-related pigment dispersal process, and their true significance as a risk factor for development of glaucoma.
The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.
Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke
2017-06-01
Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.
Endo, Takao; Fujikado, Takashi; Hirota, Masakazu; Kanda, Hiroyuki; Morimoto, Takeshi; Nishida, Kohji
2018-04-20
To evaluate the improvement in targeted reaching movements toward targets of various contrasts in a patient implanted with a suprachoroidal-transretinal stimulation (STS) retinal prosthesis. An STS retinal prosthesis was implanted in the right eye of a 42-year-old man with advanced Stargardt disease (visual acuity: right eye, light perception; left eye, hand motion). In localization tests during the 1-year follow-up period, the patient attempted to touch the center of a white square target (visual angle, 10°; contrast, 96, 85, or 74%) displayed at a random position on a monitor. The distance between the touched point and the center of the target (the absolute deviation) was averaged over 20 trials with the STS system on or off. With the left eye occluded, the absolute deviation was not consistently lower with the system on than off for high-contrast (96%) targets, but was consistently lower with the system on for low-contrast (74%) targets. With both eyes open, the absolute deviation was consistently lower with the system on than off for 85%-contrast targets. With the system on and 96%-contrast targets, we detected a shorter response time while covering the right eye, which was being implanted with the STS, compared to covering the left eye (2.41 ± 2.52 vs 8.45 ± 3.78 s, p < 0.01). Performance of a reaching movement improved in a patient with an STS retinal prosthesis implanted in an eye with residual natural vision. Patients with a retinal prosthesis may be able to improve their visual performance by using both artificial vision and their residual natural vision. Beginning date of the trial: Feb. 20, 2014 Date of registration: Jan. 4, 2014 Trial registration number: UMIN000012754 Registration site: UMIN Clinical Trials Registry (UMIN-CTR) http://www.umin.ac.jp/ctr/index.htm.
Kanellopoulos, Anastasios John
2012-01-01
To evaluate the safety and efficacy of combined transepithelial topography-guided photorefractive keratectomy (PRK) therapeutic remodeling, combined with same-day, collagen cross-linking (CXL). This protocol was used for the management of cornea blindness due to severe corneal scarring. A 57-year-old man had severe corneal blindness in both eyes. Both corneas had significant central scars attributed to a firework explosion 45 years ago, when the patient was 12 years old. Corrected distance visual acuity (CDVA) was 20/100 both eyes (OU) with refraction: +4.00, -4.50 at 135° in the right eye and +3.50, -1.00 at 55° in the left. Respective keratometries were: 42.3, 60.4 at 17° and 35.8, 39.1 at 151.3°. Cornea transplantation was the recommendation by multiple cornea specialists as the treatment of choice. We decided prior to considering a transplant to employ the Athens Protocol (combined topography-guided partial PRK and CXL) in the right eye in February 2010 and in the left eye in September 2010. The treatment plan for both eyes was designed on the topography-guided wavelight excimer laser platform. Fifteen months after the right eye treatment, the right cornea had improved translucency and was topographically stable with uncorrected distance visual acuity (UDVA) 20/50 and CDVA 20/40 with refraction +0.50, -2.00 at 5°. We noted a similar outcome after similar treatment applied in the left eye with UDVA 20/50 and CDVA 20/40 with -0.50, -2.00 at 170° at the 8-month follow-up. In this case, the introduction of successful management of severe cornea abnormalities and scarring with the Athens Protocol may provide an effective alternative to other existing surgical or medical options.
Kanellopoulos, Anastasios John
2012-01-01
Purpose To evaluate the safety and efficacy of combined transepithelial topography-guided photorefractive keratectomy (PRK) therapeutic remodeling, combined with same-day, collagen cross-linking (CXL). This protocol was used for the management of cornea blindness due to severe corneal scarring. Methods A 57-year-old man had severe corneal blindness in both eyes. Both corneas had significant central scars attributed to a firework explosion 45 years ago, when the patient was 12 years old. Corrected distance visual acuity (CDVA) was 20/100 both eyes (OU) with refraction: +4.00, −4.50 at 135° in the right eye and +3.50, −1.00 at 55° in the left. Respective keratometries were: 42.3, 60.4 at 17° and 35.8, 39.1 at 151.3°. Cornea transplantation was the recommendation by multiple cornea specialists as the treatment of choice. We decided prior to considering a transplant to employ the Athens Protocol (combined topography-guided partial PRK and CXL) in the right eye in February 2010 and in the left eye in September 2010. The treatment plan for both eyes was designed on the topography-guided wavelight excimer laser platform. Results Fifteen months after the right eye treatment, the right cornea had improved translucency and was topographically stable with uncorrected distance visual acuity (UDVA) 20/50 and CDVA 20/40 with refraction +0.50, −2.00 at 5°. We noted a similar outcome after similar treatment applied in the left eye with UDVA 20/50 and CDVA 20/40 with −0.50, −2.00 at 170° at the 8-month follow-up. Conclusion In this case, the introduction of successful management of severe cornea abnormalities and scarring with the Athens Protocol may provide an effective alternative to other existing surgical or medical options. PMID:22347790
Robison, Bruce H.
2017-01-01
The light environment of the mesopelagic realm of the ocean changes with both depth and viewer orientation, and this has probably driven the high diversity of visual adaptations found among its inhabitants. The mesopelagic ‘cockeyed’ squids of family Histioteuthidae have unusual eyes, as the left and right eyes are dimorphic in size, shape and sometimes lens pigmentation. This dimorphism may be an adaptation to the two different sources of light in the mesopelagic realm, with the large eye oriented upward to view objects silhouetted against the dim, downwelling sunlight and the small eye oriented slightly downward to view bioluminescent point sources. We used in situ video footage from remotely operated vehicles in the Monterey Submarine Canyon to observe the orientation behaviour of 152 Histioteuthis heteropsis and nine Stigmatoteuthis dofleini. We found evidence for upward orientation in the large eye and slightly downward orientation in the small eye, which was facilitated by a tail-up oblique body orientation. We also found that 65% of adult H. heteropsis (n = 69) had yellow pigmentation in the lens of the larger left eye, which may be used to break the counterillumination camouflage of their prey. Finally, we used visual modelling to show that the visual returns provided by increasing eye size are much higher for an upward-oriented eye than for a downward-oriented eye, which may explain the development of this unique visual strategy. This article is part of the themed issue ‘Vision in dim light’. PMID:28193814
Bracha, H S; Seitz, D J; Otemaa, J; Glick, S D
1987-05-19
An endogenous asymmetry in striatal dopaminergic function has been identified in rats, and related to spontaneous and drug-induced circling (rotation, turning). We have developed an electronic device for measuring in humans the same kinds of rotational movements observed in rats. Our data indicate that, without being aware of the type of information being obtained, normal men and women rotate preferentially to the left or to the right during a routine day. Women had higher average rates of rotation than men. Males that were consistently right-sided (left-hemisphere dominant) for hand, foot and eye dominance rotated more to the right than to the left, whereas left-hemisphere dominant females rotated more to the left than to the right. Subjects tested on two occasions, 6 weeks apart, exhibited consistent (significantly correlated) rotational preferences--this was much more evident in left-hemisphere dominant than in mixed dominance individuals. In view of similar animal data, the device used in this study may become a useful and objective means for obtaining quantitative information regarding the status of basal ganglia function in humans.
Studies of the vestibulo-ocular reflex on STS 4, 5 and 6
NASA Technical Reports Server (NTRS)
Thornton, William E.; Pool, Sam L.; Moore, Thomas P.; Uri, John J.
1988-01-01
The vestibulo-ocular reflex (VOR) may be altered by weightlessness. Since this reflex plays a large role in visual stabilization, it was important to document any changes caused by space flight. This is a report on findings on STS-4 through 6 and is part of a larger study of neurosensory adaptation done on STS-4 through 8. Voluntary horizontal head oscillations at 1/3 Hz with amplitude of 30 deg right and left of center were recorded by a potentiometer and compared to eye position recorded by electroculography under the following conditions: eyes open, head fixed, tracking horizontal targets switched 0, 15, and 30 degrees right and left (optokinetic reflex - OKR - and calibration); eyes open and fixed on static external target with oscillation, (vestibulo ocular reflex, eyes closed - VOR EC); eyes open and wearing opaque goggles with target fixed in imagination (vestibulo-ocular reflex, eyes shaded - VOR ES); and eyes open and fixed on a head synchronized target with head oscillation (VOR suppression). No significant changes were found in voluntary head oscillation frequency or amplitude in those with (n=5), and without (n=3), space motion sickness (SMS), with phase of flight or test condition. Variations in head oscillation were too small to have produced detectable changes in test results.
Huang, Qian; Xu, Ping; Xia, Xin; Hu, Hong-hui; Wang, Feng; Li, Hui-ming
2006-02-01
To investigate the efficacy of subretinal transplantation of CNTF gene transfected fibroblasts for preventing photoreceptor degeneration in RCS. The human fetal lung fibroblasts with high level expression of CNTF were established by liposome mediated gene transfer and MTX selection. A 5 microl of cell suspension, containing 1 x 10(5) cells, was injected through pars plana of ciliary body into the subretinal space of the right eye at postnatal 4-5 weeks, the left eye was left without injection or injected with PBS as controls. The both eyes were enucleated for histopathological examinations at 2, 4, 6, 8, 10, 12 and 15 weeks following transplantation. The level of CNTF protein (91,046.15 pg/ml) expressed in the transfected cells was determined by sandwich enzyme-linked immunosorbent assay (ELISA). The four of seven eyes examined by light microscopy and the ten of 14 eyes examined by electro microscopy showed rescue effect. The prolonged photoreceptor survival, reduction of apoptotic cells and debris were observed in transplanted eyes in comparison with untreated or sham-injected eyes. This study provides the first indication that transplanted human fibroblasts with high level expression of CNTF are able to rescue photoreceptor degeneration in RCS dystrophic rat retina.
49 CFR 393.120 - What are the rules for securing metal coils?
Code of Federal Regulations, 2011 CFR
2011-10-01
....100 through 393.114. (b) Securement of coils transported with eyes vertical on a flatbed vehicle, in a...), across the eye of the coil, to the right side of the vehicle or intermodal container (near the rearmost... intermodal container (near the forwardmost part of the coil), across the eye of the coil, to the left side of...
76 FR 29022 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... due to a traumatic injury sustained in 1982. The visual acuity in his right eye is 20/20 and in his.... Newman Mr. Newman, 50, has no light perception in his left eye due to a traumatic injury that occurred... in a CMV. Eric C. Esplin Mr. Esplin, 46, has loss of vision in his right eye due to a traumatic...
76 FR 25766 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
..., age 51, has loss of vision in his left eye due to a traumatic injury that occurred in 2002. The best.... Mr. Dean, 67, has complete loss of vision in his right eye due to a traumatic injury sustained as a.... Smith Harry, Jr. Mr. Harry, 41, has a prosthetic right eye due to a traumatic injury sustained during...
Near-to-eye electroholography via guided-wave acousto-optics for augmented reality
NASA Astrophysics Data System (ADS)
Jolly, Sundeep; Savidis, Nickolaos; Datta, Bianca; Smalley, Daniel; Bove, V. Michael
2017-03-01
Near-to-eye holographic displays act to directly project wavefronts into a viewer's eye in order to recreate 3-D scenes for augmented or virtual reality applications. Recently, several solutions for near-to-eye electroholography have been proposed based on digital spatial light modulators in conjunction with supporting optics, such as holographic waveguides for light delivery; however, such schemes are limited by the inherent low space-bandwidth product available with current digital SLMs. In this paper, we depict a fully monolithic, integrated optical platform for transparent near-to-eye holographic display requiring no supporting optics. Our solution employs a guided-wave acousto-optic spatial light modulator implemented in lithium niobate in conjunction with an integrated Bragg-regime reflection volume hologram.
Fujiwara, M; Hayashi, H; Muramatsu, I; Ueda, N
1984-01-01
The rabbit left ophthalmic nerve (first branch of the left trigeminal nerve) was cut at the intracranial, peripheral side of the trigeminal ganglion and the effects of denervation were examined using iris sphincter muscle preparations isolated from the left and right eye, as denervated and control innervated preparations, respectively. Electrical transmural stimulation produced a substance P-operated contraction, in addition to a cholinergic one, in the preparation isolated from the right control eye. The former response was abolished in the preparation isolated from the left denervated eye, thereby indicating that the trigeminal, substance P nerve ipsilaterally innervates the iris sphincter muscle. Exogenously applied carbachol and substance P produced concentration-dependent contractions in preparations isolated from either eye. Supersensitivity characterized by a decrease in median effective concentration (EC50) values and an increase in maximal response was observed in the responses to both agents of the left denervated preparation. Such supersensitivity developed slowly after trigeminal denervation and 3 weeks was required for full development. Exogenously applied KCl produced substance P-operated and direct muscle contractions in the right control preparations. In the left denervated preparations, the substance P-operated contraction was either markedly attenuated or abolished, while the direct muscle-related contraction was enhanced after trigeminal denervation. The length of the left denervated preparation was longer than that of the right control preparation, and the resting tensions required to produce maximal carbachol contraction shifted to lower values. These physical changes of the iris sphincter muscle developed within 5 days after trigeminal denervation. In the non-denervated preparation treated with capsaicin in vitro, electrical transmural stimulation and KCl failed to produce the substance P-related contraction. However, supersensitivity to neither exogenously applied substance P, carbachol and KCl nor physical changes were observed in the capsaicin-treated preparation. These results suggest that trigeminal, substance P-related nerves tonically and ipsilaterally innervate the rabbit iris sphincter muscle and that the denervation results in non-specific supersensitivity. These findings are essentially the same as those observed in various types of smooth muscles after autonomic denervation. PMID:6205140
Virtual Schooling through the Eyes of an At-Risk Student: A Case Study
ERIC Educational Resources Information Center
Barbour, Michael K.; Siko, Jason P.
2012-01-01
While much of the growth in the popularity of virtual schooling has involved at-risk students, little research exists on the experiences of these students in this largely independent setting. This paper describes a case study of an at-risk student in a rural school in the province of Newfoundland and Labrador who was enrolled in an online course…
ERIC Educational Resources Information Center
Treves, Richard; Viterbo, Paolo; Haklay, Mordechai
2015-01-01
Research into virtual field trips (VFTs) started in the 1990s but, only recently, the maturing technology of devices and networks has made them viable options for educational settings. By considering an experiment, the learning benefits of logging the movement of students within a VFT are shown. The data are visualized by two techniques:…
ERIC Educational Resources Information Center
Cody, Jeremy A.; Craig, Paul A.; Loudermilk, Adam D.; Yacci, Paul M.; Frisco, Sarah L.; Milillo, Jennifer R.
2012-01-01
A novel stereochemistry lesson was prepared that incorporated both handheld molecular models and embedded virtual three-dimensional (3D) images. The images are fully interactive and eye-catching for the students; methods for preparing 3D molecular images in Adobe Acrobat are included. The lesson was designed and implemented to showcase the 3D…
Simulation fidelity of a virtual environment display
NASA Technical Reports Server (NTRS)
Nemire, Kenneth; Jacoby, Richard H.; Ellis, Stephen R.
1994-01-01
We assessed the degree to which a virtual environment system produced a faithful simulation of three-dimensional space by investigating the influence of a pitched optic array on the perception of gravity-referenced eye level (GREL). We compared the results with those obtained in a physical environment. In a within-subjects factorial design, 12 subjects indicated GREL while viewing virtual three-dimensional arrays at different static orientations. A physical array biased GREL more than did a geometrically identical virtual pitched array. However, addition of two sets of orthogonal parallel lines (a grid) to the virtual pitched array resulted in as large a bias as that obtained with the physical pitched array. The increased bias was caused by longitudinal, but not the transverse, components of the grid. We discuss implications of our results for spatial orientation models and for designs of virtual displays.
76 FR 34136 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... 49, has had retinal scarring in his left eye due to a traumatic injury since childhood. The visual... due to a traumatic injury that occurred in 2003. The best corrected visual acuity in his right eye is.... [[Page 34138
77 FR 59248 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-26
.... Christopher K. Foot Mr. Foot, 46, has a prosthetic right eye due to traumatic injury sustained in 1970. The... signal. Jose S. Chavez Mr. Chavez, 47, had a rupture in his left eye due to an injury sustained in 1984...
Trunk- and head-centred spatial coordinates do not affect free-viewing perceptual asymmetries.
Nicholls, Michael E R; Mattingley, Jason B; Bradshaw, John L; Krins, Phillip W
2003-11-01
Turning the trunk or head to the left can reduce the severity of leftward neglect. This study sought to determine whether turning the trunk or head to the right would reduce pseudoneglect: A phenomenon where normal participants underestimate the rightward features of a stimulus. Participants made luminance judgements of two mirror-reversed greyscales stimuli. A preference for selecting the stimulus dark on the left was found. The effect of trunk-centred coordinates was examined in Expt. 1 by facing the head toward the display and turning the trunk to the left, right or toward the display. Head-centred coordinates were examined in Expt. 2 by directing the eyes toward the display and then turning the head and trunk. No effect of rotation was observed. It was concluded that the leftward bias for the greyscales task could be based on an object-centred attentional bias or left-to-right eye scanning habits.
Estimating the gaze of a virtuality human.
Roberts, David J; Rae, John; Duckworth, Tobias W; Moore, Carl M; Aspin, Rob
2013-04-01
The aim of our experiment is to determine if eye-gaze can be estimated from a virtuality human: to within the accuracies that underpin social interaction; and reliably across gaze poses and camera arrangements likely in every day settings. The scene is set by explaining why Immersive Virtuality Telepresence has the potential to meet the grand challenge of faithfully communicating both the appearance and the focus of attention of a remote human participant within a shared 3D computer-supported context. Within the experiment n=22 participants rotated static 3D virtuality humans, reconstructed from surround images, until they felt most looked at. The dependent variable was absolute angular error, which was compared to that underpinning social gaze behaviour in the natural world. Independent variables were 1) relative orientations of eye, head and body of captured subject; and 2) subset of cameras used to texture the form. Analysis looked for statistical and practical significance and qualitative corroborating evidence. The analysed results tell us much about the importance and detail of the relationship between gaze pose, method of video based reconstruction, and camera arrangement. They tell us that virtuality can reproduce gaze to an accuracy useful in social interaction, but with the adopted method of Video Based Reconstruction, this is highly dependent on combination of gaze pose and camera arrangement. This suggests changes in the VBR approach in order to allow more flexible camera arrangements. The work is of interest to those wanting to support expressive meetings that are both socially and spatially situated, and particular those using or building Immersive Virtuality Telepresence to accomplish this. It is also of relevance to the use of virtuality humans in applications ranging from the study of human interactions to gaming and the crossing of the stage line in films and TV.
NASA Astrophysics Data System (ADS)
Kersten, T. P.; Büyüksalih, G.; Tschirschwitz, F.; Kan, T.; Deggim, S.; Kaya, Y.; Baskaraca, A. P.
2017-05-01
Recent advances in contemporary Virtual Reality (VR) technologies are going to have a significant impact on veryday life. Through VR it is possible to virtually explore a computer-generated environment as a different reality, and to immerse oneself into the past or in a virtual museum without leaving the current real-life situation. For such the ultimate VR experience, the user should only see the virtual world. Currently, the user must wear a VR headset which fits around the head and over the eyes to visually separate themselves from the physical world. Via the headset images are fed to the eyes through two small lenses. Cultural heritage monuments are ideally suited both for thorough multi-dimensional geometric documentation and for realistic interactive visualisation in immersive VR applications. Additionally, the game industry offers tools for interactive visualisation of objects to motivate users to virtually visit objects and places. In this paper the generation of a virtual 3D model of the Selimiye mosque in the city of Edirne, Turkey and its processing for data integration into the game engine Unity is presented. The project has been carried out as a co-operation between BİMTAŞ, a company of the Greater Municipality of Istanbul, Turkey and the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg, Germany to demonstrate an immersive and interactive visualisation using the new VR system HTC Vive. The workflow from data acquisition to VR visualisation, including the necessary programming for navigation, is described. Furthermore, the possible use (including simultaneous multiple users environments) of such a VR visualisation for a CH monument is discussed in this contribution.
Diers, Martin; Kamping, Sandra; Kirsch, Pinar; Rance, Mariela; Bekrater-Bodmann, Robin; Foell, Jens; Trojan, Joerg; Fuchs, Xaver; Bach, Felix; Maaß, Heiko; Cakmak, Hüseyin; Flor, Herta
2015-01-12
Extended viewing of movements of one's intact limb in a mirror as well as motor imagery have been shown to decrease pain in persons with phantom limb pain or complex regional pain syndrome and to increase the movement ability in hemiparesis following stroke. In addition, mirrored movements differentially activate sensorimotor cortex in amputees with and without phantom limb pain. However, using a so-called mirror box has technical limitations, some of which can be overcome by virtual reality applications. We developed a virtual reality mirror box application and evaluated its comparability to a classical mirror box setup. We applied both paradigms to 20 healthy controls and analyzed vividness and authenticity of the illusion as well as brain activation patterns. In both conditions, subjects reported similar intensities for the sensation that movements of the virtual left hand felt as if they were executed by their own left hand. We found activation in the primary sensorimotor cortex contralateral to the actual movement, with stronger activation for the virtual reality 'mirror box' compared to the classical mirror box condition, as well as activation in the primary sensorimotor cortex contralateral to the mirrored/virtual movement. We conclude that a virtual reality application of the mirror box is viable and that it might be useful for future research. Copyright © 2014 Elsevier B.V. All rights reserved.
Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P; Elia, Maurizio
2014-08-01
This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and investigating the real efficacy of high-frequency repetitive transcranial magnetic stimulation by comparing three kinds of treatments (high-frequency repetitive transcranial magnetic stimulation, a traditional eye-hand integration training, and both treatments combined). Results showed a significant increase in eye-hand performances only when high-frequency repetitive transcranial magnetic stimulation was delivered on the left premotor cortex; a persistent improvement up to 1 h after the end of the stimulation; better outcomes in the treatment combining high-frequency repetitive transcranial magnetic stimulation and eye-hand integration training. Based on these preliminary findings, further evaluations on the usefulness of high-frequency repetitive transcranial magnetic stimulation in rehabilitation of children with autism are strongly recommended. © The Author(s) 2013.
Rico-Sergado, Laura; Pérez-Canales, Jose L; Pérez-Santonja, Juan J; Cigüenza-Sancho, Sonia
2015-04-01
A 53-year-old cachectic patient diagnosed with major depressive disorder was referred to our department for evaluation of a visible deformation of the right eye. She had been wearing hydrogel contact lenses on a continuous basis without removal for the last 12 months, influenced by low self-esteem and social isolation. Slit-lamp examination of the right eye showed a conical cornea, extensive neovascularization, severe stromal melting with descemetocele formation and forward bulging of the iris. Examination of the left eye revealed multiple corneal opacities, deep stromal neovascularization and anterior chamber inflammation. No sign of infection was present. Vitamin A deficiency was suspected and later confirmed. The patient required evisceration of the right eye and psychiatric treatment. Inflammatory signs of the left eye resolved within 1 week of initiating treatment. This case illustrates the synergistic effect of soft contact lens abuse and vitamin A deficiency in a psychiatric patient, and emphasizes the importance of instructing vulnerable patients on appropriate lens use and care. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Chatziralli, Irini; Theodossiadis, George; Brouzas, Dimitrios; Emfietzoglou, Ioannis; Theodossiadis, Panagiotis
2017-01-01
We present the evolution of X-linked juvenile retinoschisis (XLRS) in a male patient using optical coherence tomography (OCT) with a long-term follow-up time of 15 years. A 10-year-old male patient presented at the Medical Retina Department of our hospital complaining for blurred vision in both eyes. At the initial presentation in 2001, his best corrected visual acuity (BCVA) was 6/12 in both eyes on the Snellen chart. Based on clinical and OCT findings, the diagnosis of XLRS was made, and it was confirmed by genetic testing. No treatment was performed, but the patient was regularly examined. His BCVA and OCT findings remained relatively stable from 2001 to 2012, when BCVA decreased to 6/18 and 6/24 in the right and left eye, respectively. In 2016, his BCVA was 6/24 and 6/36 in right and left eye, respectively, while OCT depicted significant macular thinning, accompanied by irregularities of the foveal contour in both eyes. Patients with XLRS should be monitored regularly to evaluate the progression of the disease and manage the potential complications.
Perceptual Issues of Augmented and Virtual Environments
2007-07-01
distinct preference for one eye over the other. This is typically, quickly, and easily found through sighting tests (Peli, 1990). This eye dominance...been researched extensively and for different purposes. The entertainment industry has also experimented with synthetic smell production, in the...form of accompanying smells to enhance the experience of films (Lefcowitz, 2001, Somerson, 2001). In the Aroma Rama and the Smell -o-vision systems
Virtual egocenters as a function of display geometric field of view and eye station point
NASA Technical Reports Server (NTRS)
Psotka, Joseph
1993-01-01
The accurate location of one's virtual egocenter in a geometric space is of critical importance for immersion technologies. This experiment was conducted to investigate the role of field of view (FOV) and observer station points in the perception of the location of one's egocenter (the personal viewpoint) in virtual space. Rivalrous cues to the accurate location of one's egocenter may be one factor involved in simulator sickness. Fourteen subjects viewed an animated 3D model, of the room in which they sat, binocularly, from Eye Station Points (ESP) of either 300 or 800 millimeters. The display was on a 190 by 245 mm monitor, at a resolution of 320 by 200 pixels with 256 colors. They saw four models of the room designed with four geometric field of view (FOVg) conditions of 18, 48, 86, and 140 degrees. They drew the apparent paths of the camera in the room on a bitmap of the room as seen from infinity above. Large differences in the paths of the camera were seen as a function of both FOVg and ESP. Ten of the subjects were then asked to find the position for each display that minimized camera motion. The results fit well with predictions from an equation that took the ratio of human FOV (roughly 180 degrees) to FOVg times the Geometric Eye Point (GEP) of the imager: Zero Station Point = (180/FOVg)*GEP
Iu, Lawrence P L; Fan, Michelle C Y; Lam, Wai-Ching; Wong, Ian Y H
2018-02-09
Cytomegalovirus (CMV) retinitis is an opportunistic infection that primarily affects immunocompromised individuals. Intravitreal ganciclovir injection monotherapy or in combination with systemic anti-CMV therapy are effective treatments for CMV retinitis. Crystallization of ganciclovir after intravitreal injection is extremely rare. Only two cases had been reported in literature. Crystallization in only one eye after bilateral injections had not been reported before. We hereby report a case of intraocular ganciclovir crystallization in one eye after bilateral intravitreal injections, and repeated crystallization in the same eye after repeated injections. A 79-year-old patient had bilateral cytomegalovirus retinitis and received bilateral intravitreal ganciclovir injections of 2.5 mg in 0.05 ml sterile water. Fundus examination after injection showed formation of needle-shaped, golden-yellow crystals in the vitreous of right eye but not in left eye. The crystals dissolved spontaneously. Repeated bilateral intravitreal ganciclovir injections 4 days later resulted in repeated crystallization of ganciclovir in right eye but not in left eye. The crystals dissolved spontaneously and completely after 5 minutes. Visual acuity remained unchanged and intraocular pressure was normal. Intraocular ganciclovir crystallization could occur after intravitreal injections. It is important to perform fundus examination after injection. The crystals may dissolve rapidly and vitrectomy may not be necessary. Our case suggested intraocular ganciclovir crystallization is an idiosyncratic phenomenon, subjects to distinctive intraocular environment which could be different between two eyes of the same patient. The susceptible intraocular environment could be persistent leading to repeated crystallization.
Orofacial pain and headaches associated with exfoliation glaucoma.
Noma, Noboru; Iwasa, Mayumi; Young, Andrew; Ikeda, Mariko; Hsu, Yung-Chu; Yamamoto, Maasa; Inoue, Kenji; Imamura, Yoshiki
2017-12-01
Exfoliation syndrome is the most common identifiable cause of open-angle glaucoma. The authors report a case of exfoliation glaucoma in a patient who had orofacial pain. A 77-year-old woman was treated at the orofacial pain clinic for left-sided facial pain and headaches of 7 months' duration. Her cataracts and open-angle glaucoma had been diagnosed approximately 3 years earlier. Her main symptoms were orofacial pain, eye redness, inflammation of the eyelids, and eyelid edema. Magnetic resonance imaging showed no evidence of intracranial or extracranial pathology. Hemicrania continua was considered as a possible diagnosis. Indomethacin was prescribed but did not affect her headaches. She then went to an ophthalmologist to rule out secondary headaches. Intraocular pressure was 13 millimeters of mercury in the right eye and 67 mm Hg in the left eye. The ophthalmologist made a diagnosis of exfoliation glaucoma, and the patient underwent surgical treatment for the glaucoma and cataracts. After surgery, she was free of symptoms, and intraocular pressure was 15 mm Hg in the left eye. During differential diagnosis, dentists need to consider intraoral and systemic conditions that can mimic odontogenic or orofacial pain disorders in the patient's medical history and that have a higher incidence associated with the patient's age. Copyright © 2017 American Dental Association. Published by Elsevier Inc. All rights reserved.
Dolz-Marco, Rosa; Sarraf, David; Giovinazzo, Vincent; Freund, K Bailey
2017-01-01
To describe multimodal imaging findings of an evolving case of acute posterior multifocal placoid pigment epitheliopathy occurring in a young healthy male. Case report of a patient with acute posterior multifocal placoid pigment epitheliopathy including comprehensive systemic and ocular examinations. Ultra-widefield autofluorescence, fluorescein angiography, indocyanine green angiography, and serial optical coherence tomography angiography were performed. A 34-year-old male presented with acute vision loss in his left eye for 2 weeks. His best-corrected visual acuity was 20/20 in his right eye and 20/200 in his left eye. Dilated funduscopic examination revealed multiple creamy white deep retinal lesions showing macular involvement of the left eye with a diffuse area of pigmentary changes. The presence of multiple areas of hypoperfusion of the inner choroid were demonstrated with fluorescein and indocyanine green angiography. Serial optical coherence tomography angiography showed multiple evolving areas of decreased flow at the level of the inner choroid. Although the pathogenesis of acute posterior multifocal placoid pigment epitheliopathy remains unknown, there is growing evidence of a primary choroidal involvement with secondary damage to the overlying retinal pigment epithelium and the outer retinal layers. Optical coherence tomography angiography may provide valuable information for the diagnosis and follow-up of this condition avoiding invasive angiographic procedures.
Bang, Yo-Soon; Son, Kyung Hyun; Kim, Hyun Jin
2016-11-01
[Purpose] The purpose of this study is to investigate the effects of virtual reality training using Nintendo Wii on balance and walking for stroke patients. [Subjects and Methods] Forty stroke patients with stroke were randomly divided into two exercise program groups: virtual reality training (n=20) and treadmill (n=20). The subjects underwent their 40-minute exercise program three times a week for eight weeks. Their balance and walking were measured before and after the complete program. We measured the left/right weight-bearing and the anterior/posterior weight-bearing for balance, as well as stance phase, swing phase, and cadence for walking. [Results] For balance, both groups showed significant differences in the left/right and anterior/posterior weight-bearing, with significant post-program differences between the groups. For walking, there were significant differences in the stance phase, swing phase, and cadence of the virtual reality training group. [Conclusion] The results of this study suggest that virtual reality training providing visual feedback may enable stroke patients to directly adjust their incorrect weight center and shift visually. Virtual reality training may be appropriate for patients who need improved balance and walking ability by inducing their interest for them to perform planned exercises on a consistent basis.
Bang, Yo-Soon; Son, Kyung Hyun; Kim, Hyun Jin
2016-01-01
[Purpose] The purpose of this study is to investigate the effects of virtual reality training using Nintendo Wii on balance and walking for stroke patients. [Subjects and Methods] Forty stroke patients with stroke were randomly divided into two exercise program groups: virtual reality training (n=20) and treadmill (n=20). The subjects underwent their 40-minute exercise program three times a week for eight weeks. Their balance and walking were measured before and after the complete program. We measured the left/right weight-bearing and the anterior/posterior weight-bearing for balance, as well as stance phase, swing phase, and cadence for walking. [Results] For balance, both groups showed significant differences in the left/right and anterior/posterior weight-bearing, with significant post-program differences between the groups. For walking, there were significant differences in the stance phase, swing phase, and cadence of the virtual reality training group. [Conclusion] The results of this study suggest that virtual reality training providing visual feedback may enable stroke patients to directly adjust their incorrect weight center and shift visually. Virtual reality training may be appropriate for patients who need improved balance and walking ability by inducing their interest for them to perform planned exercises on a consistent basis. PMID:27942130
Iorizzo, Dana B.; Riley, Meghan E.; Hayhoe, Mary; Huxlin, Krystel R.
2011-01-01
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ~80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ~90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. PMID:21414339
Iorizzo, Dana B; Riley, Meghan E; Hayhoe, Mary; Huxlin, Krystel R
2011-05-25
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ∼80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ∼90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. Copyright © 2011 Elsevier Ltd. All rights reserved.
Vitish-Sharma, P; Knowles, J; Patel, B
2011-01-01
Laparoscopic surgery requires working in a three-dimensional environment with a two-dimensional view. Skills such as depth perception, hand to eye co-ordination and bimanual manipulation are crucial to its efficacy. To compare the efficiency of training in laparoscopic skills on a VR simulator with a traditional box trainer. Twenty medical students were recruited. An initial training session on the relevant anatomy and steps of a laparoscopic cholecystectomy was given. Baseline skills were recorded using a pre-training laparoscopic cholecystectomy on the VR trainer. Parameters measured were: (1) total time taken (mins); (2) number of movements right and left instrument; (3) path length (cms) of right and left instrument was recorded. Ten students trained on a VR simulator, and ten on a box trainer, for three hours each. The box trainer group exercises were based on the Royal College of Surgeons core laparoscopic skills course, and the VR trainer exercises were based on the Simbionix LapMentor basic skills tasks. Following this both groups were reassessed by a laparoscopic cholecystectomy on the VR trainer. Both groups showed improvement in all measured parameters. A student T-test at 95% confidence interval showed no statistically significant difference between the two groups pre and post training. Both the VR and box trainer are effective in the acquisition of laparoscopic skills. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
An application of the MPP to the interactive manipulation of stereo images of digital terrain models
NASA Technical Reports Server (NTRS)
Pol, Sanjay; Mcallister, David; Davis, Edward
1987-01-01
Massively Parallel Processor algorithms were developed for the interactive manipulation of flat shaded digital terrain models defined over grids. The emphasis is on real time manipulation of stereo images. Standard graphics transformations are applied to a 128 x 128 grid of elevations followed by shading and a perspective projection to produce the right eye image. The surface is then rendered using a simple painter's algorithm for hidden surface removal. The left eye image is produced by rotating the surface 6 degs about the viewer's y axis followed by a perspective projection and rendering of the image as described above. The left and right eye images are then presented on a graphics device using standard stereo technology. Performance evaluations and comparisons are presented.
Treatment of Phthiriasis Palpebrarum and Crab Louse: Petrolatum Jelly and 1% Permethrin Shampoo
Karabela, Yunus; Yardimci, Gurkan; Yildirim, Isik; Karabela, Semsi Nur
2015-01-01
Phthiriasis palpebrarum is an uncommon cause of blepharoconjunctivitis in which Pthirus pubis infest the eyelashes. We report a case of unilateral phthiriasis palpebrarum with crab louse. A 45-year-old man presented with conjunctival hyperaemia and moderate itching associated with irritation, and crusty excretions of the eyelashes in the left eye. Careful slit-lamp examination revealed many lice and nits in left eye and mild conjunctival hyperaemia. No abnormality was found in the right eye. On dermatologic examination, only one louse was found at the pubic area. The patient was treated effectively with petrolatum jelly (Vaseline) and 1% permethrin shampoo (Kwellada 1% shampoo). At the end of the first week no louse or nit was present on eyelashes and pubic area. PMID:26451147
Hendricks, Theo J W; de Brabander, John; Vankan-Hendricks, Marlou H P; van der Horst, Frans G; Hendrikse, Fred; Knottnerus, J Andre
2009-08-01
Refractive error (RE) is suggested to cause not only visual impairment, but also functional problems such as aspecific health complaints and lower levels of school achievement. During the last few decades the prevalence of myopia has increased worldwide, especially in Asia. We investigated the prevalence of habitual RE and anisometropia in a Dutch population of children and employees. In a cross-sectional study, RE in both eyes of 520 children (aged 11-13 years) and 444 hospital employees (aged 17-60 years) were measured using an autorefractometer. The measurements were performed without using a cycloplegium. Pearson's correlation coefficient (r) was used to analyse correlations between the right and left eyes. Chi-square tests were used to test the differences between subgroups according to gender and age. In schoolchildren 28% of right eyes were myopic (> 0.50 D) and 8% hyperopic (> 0.50 D). Pearson's r between right and left eyes for spherical equivalent power (SEP) was 0.93. The mean cylinder deviation in right eyes was 0.26 D (range 0.00-4.50 D). Anisometropia > 1.00 D was present in 4.6% of children; 22% of children were not optimally (> 0.50 D) corrected. In hospital employees, 30% of right eyes were myopic (> 0.50 D) and 10% hyperopic (> 0.50 D). Pearson's r between right and left eyes for SEP was 0.53. The mean cylinder deviation in right eyes was 0.35 D (range 0.00-5.75 D). Anisometropia > 1.00 D was present in 25% of employees. Anisometropia was more frequently present in employees aged 40-60 years, than in those aged 17-39 years (30% versus 18%; p = 0.02, Cramer's V = 0.15). Refractive errors are common in children aged 11-13 years and in working adults aged 17-60 years. Distributions of sphere and cylinder deviations are similar for Dutch schoolchildren and hospital employees. Surprisingly, anisometropia proved to be more prevalent with age. In children many eyes are not optimally corrected. Increased attention should be paid to uncorrected and miscorrected REs.
Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production
Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.
2014-01-01
Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767
Takako, Hidaka; Hideki, Chuman; Nobuhisa, Nao-I
2017-10-01
To evaluate optic nerve head (ONH) blood flow in normal rats and a rodent model of non-arteritic ischemic optic neuropathy (rNAION) in vivo using laser speckle flowgraphy (LSFG). Rats were under general anesthesia; to induce NAION, Rose Bengal (RB) was injected into the tail vein. After the administration of RB, the left ONH was photoactivated using an argon green laser. We measured ONH blood flow in the normal rats and the rNAION group (at 1, 3, 7, 14, and 28 days after the induction of NAION) using an LSFG-Micro. We used the mean blur rate (MBR) of the vessel region (MV) and MBR of the tissue region (MT) as indicators of blood flow. We compared the MBR of the right and left eyes in both the normal rats and the rNAION group. In the normal rats, there were no significant differences in MV or MT between the right and left eyes. In the rNAION group, the MV and MT of the affected eyes were significantly lower than those of the unaffected eyes at all time points. There were significant differences between the left/right MV and MT ratios seen before the induction of NAION and those observed at 1, 3, 7, 14, and 28 days after the induction of NAION. However, there were no significant differences in these parameters among any of post-NAION induction time points. Our results indicated that the ONH blood flow of the rNAION rats fell in the acute and chronic phases.
New Record Five-Wheel Drive, Spirit's Sol 1856 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11962 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11962 NASA's Mars Exploration Rover Spirit used its navigation camera to take the images that have been combined into this stereo, 180-degree view of the rover's surroundings during the 1,856th Martian day, or sol, of Spirit's surface mission (March 23, 2009). The center of the view is toward the west-southwest. This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 25.82 meters (84.7 feet) west-northwestward earlier on Sol 1856. This is the longest drive on Mars so far by a rover using only five wheels. Spirit lost the use of its right-front wheel in March 2006. Before Sol 1856, the farthest Spirit had covered in a single sol's five-wheel drive was 24.83 meters (81.5 feet), on Sol 1363 (Nov. 3, 2007). The Sol 1856 drive made progress on a route planned for taking Spirit around the western side of the low plateau called 'Home Plate.' A portion of the northwestern edge of Home Plate is prominent in the left quarter of this image, toward the south. This view is presented as a cylindrical-perspective projection with geometric seam correction.Whose point-of-view is it anyway?
NASA Astrophysics Data System (ADS)
Garvey, Gregory P.
2011-03-01
Shared virtual worlds such as Second Life privilege a single point-of-view, namely that of the user. When logged into Second Life a user sees the virtual world from a default viewpoint, which is from slightly above and behind the user's avatar (the user's alter ego 'in-world.') This point-of-view is as if the user were viewing his or her avatar using a camera floating a few feet behind it. In fact it is possible to set the view to as if you were seeing the world through the eyes of your avatar or you can even move the camera completely independent of your avatar. A change in point-of-view, means, more than just a different camera point-of-view. The practice of using multiple avatars requires a transformation of identity and personality. When a user 'enacts' the identity of a particular avatar, their 'real' personality is masked by the assumed personality. The technology of virtual worlds permits both a change of point-of -view and also facilitates a change in identity. Does this cause any psychological distress? Or is the ability to be someone else and see a world (a game, a virtual world) through a different set of eyes somehow liberating and even beneficial?
Principi, S; Farah, J; Ferrari, P; Carinou, E; Clairand, I; Ginjaume, M
2016-09-01
This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Adams, Daniel L.; Economides, John R.
2015-01-01
To probe the mechanism of visual suppression, we have raised macaques with strabismus by disinserting the medial rectus muscle in each eye at 1 mo of age. Typically, this operation produces a comitant, alternating exotropia with normal acuity in each eye. Here we describe an unusual occurrence: the development of severe amblyopia in one eye of a monkey after induction of exotropia. Shortly after surgery, the animal demonstrated a strong fixation preference for the left eye, with apparent suppression of the right eye. Later, behavioral testing showed inability to track or to saccade to targets with the right eye. With the left eye occluded, the animal demonstrated no visually guided behavior. Optokinetic nystagmus was absent in the right eye. Metabolic activity in striate cortex was assessed by processing the tissue for cytochrome oxidase (CO). Amblyopia caused loss of CO in one eye's rows of patches, presumably those serving the blind eye. Layers 4A and 4B showed columns of reduced CO, in register with pale rows of patches in layer 2/3. Layers 4C, 5, and 6 also showed columns of CO activity, but remarkably, comparison with more superficial layers showed a reversal in contrast. In other words, pale CO staining in layers 2/3, 4A, and 4B was aligned with dark CO staining in layers 4C, 5, and 6. No experimental intervention or deprivation paradigm has been reported previously to produce opposite effects on metabolic activity in layers 2/3, 4A, and 4B vs. layers 4C, 5, and 6 within a given eye's columns. PMID:25810480
Adams, Daniel L; Economides, John R; Horton, Jonathan C
2015-05-01
To probe the mechanism of visual suppression, we have raised macaques with strabismus by disinserting the medial rectus muscle in each eye at 1 mo of age. Typically, this operation produces a comitant, alternating exotropia with normal acuity in each eye. Here we describe an unusual occurrence: the development of severe amblyopia in one eye of a monkey after induction of exotropia. Shortly after surgery, the animal demonstrated a strong fixation preference for the left eye, with apparent suppression of the right eye. Later, behavioral testing showed inability to track or to saccade to targets with the right eye. With the left eye occluded, the animal demonstrated no visually guided behavior. Optokinetic nystagmus was absent in the right eye. Metabolic activity in striate cortex was assessed by processing the tissue for cytochrome oxidase (CO). Amblyopia caused loss of CO in one eye's rows of patches, presumably those serving the blind eye. Layers 4A and 4B showed columns of reduced CO, in register with pale rows of patches in layer 2/3. Layers 4C, 5, and 6 also showed columns of CO activity, but remarkably, comparison with more superficial layers showed a reversal in contrast. In other words, pale CO staining in layers 2/3, 4A, and 4B was aligned with dark CO staining in layers 4C, 5, and 6. No experimental intervention or deprivation paradigm has been reported previously to produce opposite effects on metabolic activity in layers 2/3, 4A, and 4B vs. layers 4C, 5, and 6 within a given eye's columns. Copyright © 2015 the American Physiological Society.
Defense Mechanisms, Psychosomatic Symptomatology, and Conjugate Lateral Eye Movements
ERIC Educational Resources Information Center
Gur, Raquel E.; Gur, Ruben C.
1975-01-01
Subjects were classified into left movers, right movers, and bidirectionals according to the characteristic direction of their eye movements in response to questions. The three groups were compared on their preferential use of defense mechanisms and on the number of psychosomatic complaints. (Author)
Histiocytic Sarcoma and Bilateral Facial Vein Thrombosis in a Siberian Hamster (Phodopus sungorus).
Coble, Dondrae J; Shoemaker, Margaret; Harrington, Bonnie; Dardenne, Adrienne D; Bolon, Brad
2015-04-01
A 21-mo-old, male Siberian hamster (Phodopus sungorus) presented with left-sided facial swelling, proptosis of the left eye, and blepharospasm of the right eye. The hamster had been used only for breeding. Because of the poor prognosis, the hamster was euthanized without additional diagnostic assays or treatments. Routine gross pathologic evaluation demonstrated exophthalmos and presumptive hyphema of the left eye, bilateral facial edema, freely movable nodules within the mesentery, white foci within the liver, and a large mass effacing the cranial pole of the right kidney. On histologic evaluation, the mesenteric nodules and liver foci expressed histiocytic marker CD163 and thus were diagnosed as sites of histiocytic sarcoma, whereas the kidney mass was a well-differentiated renal cell carcinoma. The facial swelling resulted from bilateral, chronic, severe, branching thrombi in many facial veins. Additional age-related histopathologic findings were observed in other organs, including diffuse glomerulopathy, nesidioblastosis (pancreatic islet neoformation), and multiple foci of severe cartilage degeneration in the axial skeleton. To our knowledge, this report provides the first description of histiocytic sarcoma in a Siberian hamster.
Recoverin-associated retinopathy secondary to Warthin tumor of parotid gland.
Machida, Shigeki; Ohguro, Hiroshi; Ishida, Kazunori; Suzuki, Masamichi; Kawagishi, Kazuaki
2014-10-01
To present a case of photoreceptor degeneration associated with a benign Warthin tumor of the parotid gland. A 57-year-old man visited our clinic complaining of blurred vision in both eyes. His best-corrected visual acuity was 0.07 in the right and 0.04 in the left eyes. All components of the full-field electroretinograms (ERGs) were reduced in both eyes. The focal macular ERGs were extinguished in both eyes, which was consistent with the deterioration of the outer retina in optical coherence tomographic images. Positron emission tomography showed (18)F-fluorodeoxy glucose accumulation in the left parotid gland. Parotidectomy was performed, and the histopathology of the specimen had features compatible with a Warthin tumor without malignancy. Western blot analysis of the patient's sera detected an antibody against recoverin. In addition, the tumor tissue had an aberrant expression of recoverin. The findings in this case indicate that recoverin-associated retinopathy can develop secondary to a benign Warthin tumor.
A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.
Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I
2013-12-01
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
Opportunity's Surroundings on Sol 1687 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11739 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11739 NASA's Mars Exploration Rover Opportunity used its navigation camera to take the images combined into this stereo, 360-degree view of the rover's surroundings on the 1,687th Martian day, or sol, of its surface mission (Oct. 22, 2008). The view appears three-dimensional when viewed through red-blue glasses. Opportunity had driven 133 meters (436 feet) that sol, crossing sand ripples up to about 10 centimeters (4 inches) tall. The tracks visible in the foreground are in the east-northeast direction. Opportunity's position on Sol 1687 was about 300 meters southwest of Victoria Crater. The rover was beginning a long trek toward a much larger crater, Endeavour, about 12 kilometers (7 miles) to the southeast. This panorama combines right-eye and left-eye views presented as cylindrical-perspective projections with geometric seam correction.Statis omnidirectional stereoscopic display system
NASA Astrophysics Data System (ADS)
Barton, George G.; Feldman, Sidney; Beckstead, Jeffrey A.
1999-11-01
A unique three camera stereoscopic omnidirectional viewing system based on the periscopic panoramic camera described in the 11/98 SPIE proceedings (AM13). The 3 panoramic cameras are equilaterally combined so each leg of the triangle approximates the human inter-ocular spacing allowing each panoramic camera to view 240 degree(s) of the panoramic scene, the most counter clockwise 120 degree(s) being the left eye field and the other 120 degree(s) segment being the right eye field. Field definition may be by green/red filtration or time discrimination of the video signal. In the first instance a 2 color spectacle is used in viewing the display or in the 2nd instance LCD goggles are used to differentiate the R/L fields. Radially scanned vidicons or re-mapped CCDs may be used. The display consists of three vertically stacked 120 degree(s) segments of the panoramic field of view with 2 fields/frame. Field A being the left eye display and Field B the right eye display.
De Salvo, Gabriella; Li Calzi, Concetta; Anastasi, Mario; Lodato, Gaetano
2009-01-01
To describe a rare branch retinal vein occlusion (BRVO) followed by central retinal artery occlusion (CRAO) in a patient with Churg-Strauss syndrome (CSS). A 55-year-old man with a not yet diagnosed CSS developed a BRVO in the left eye and 1 year later a CRAO with painless and acute vision loss in the same eye. Medical history included bronchial asthma, history of allergy, eosinophilic pneumonia, bilateral pleuric and pericardial effusion, hypereosinophilia, and purpuric vasculitis. CRAO in the left eye was diagnosed by retinal whitening and a cherry red spot with coexisting old BRVO evidenced by previous laser photocoagulation. Corticosteroids and cyclophosphamide therapy improved his general condition but no visual recovery occurred. BRVO and CRAO can occur in the same eye in CSS. In the presence of systemic signs or symptoms, it is important to rule out systemic vasculitis in order to start appropriate immune-modulatory treatment thereby avoiding unnecessary mortality.
Direct stimulation of the retina by the method of virtual-quanta for heavy cosmic-ray nuclei
NASA Technical Reports Server (NTRS)
Mcnulty, P. J.; Madey, R.
1972-01-01
The contribution to the frequency of visual sensations induced in the dark-adapted eye by the virtual photon field was calculated, this field is associated with the heavy nuclei that exist in space beyond the geomagnetic field. In order to determine the probability that the virtual photon field induces a light flash, only the portion of the virtual photon spectrum that corresponds to the known frequency dependence of the sensitivity of human rods to visible light was utilized. The results can be expressed as a curve of the mean frequency of light flashes induced by the absorption of at least R virtual photons versus the threshold number R. The contribution to the light flash frequency from the virtual photon field of heavy cosmic ray nuclei is smaller than that from Cerenkov photons. The flux and energy spectra of galactic cosmic ray nuclei helium to iron were used.
Ahnood, Dana; Souriti, Ahmad; Williams, Gwyn Samuel
2018-06-01
To explore the views of patients with diabetic retinopathy and maculopathy on their acceptance of virtual clinic review in place of face-to-face clinic appointments. A postal survey was mailed to all 813 patients under the care of the diabetic eye clinic at Singleton Hospital with 7 questions, explanatory information, and a stamped, addressed envelope available for returning completed questionnaires. Four hundred and ninety-eight questionnaires were returned indicating that 86.1% were supportive of the idea of virtual clinics, although only 56.9% were prepared for every visit to be virtual. Of respondents, 6.6% not happy to attend any virtual clinic. This is by far the largest survey of patients' attitudes regarding attending virtual clinics and confirms that the vast majority are supportive of this mode of health care delivery. Copyright © 2018 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Chromatically corrected virtual image visual display. [reducing eye strain in flight simulators
NASA Technical Reports Server (NTRS)
Kahlbaum, W. M., Jr. (Inventor)
1980-01-01
An in-line, three element, large diameter, optical display lens is disclosed which has a front convex-convex element, a central convex-concave element, and a rear convex-convex element. The lens, used in flight simulators, magnifies an image presented on a television monitor and, by causing light rays leaving the lens to be in essentially parallel paths, reduces eye strain of the simulator operator.
The use of video capture virtual reality in burn rehabilitation: the possibilities.
Haik, Josef; Tessone, Ariel; Nota, Ayala; Mendes, David; Raz, Liat; Goldan, Oren; Regev, Elli; Winkler, Eyal; Mor, Elisheva; Orenstein, Arie; Hollombe, Ilana
2006-01-01
We independently explored the use of the Sony PlayStation II EyeToy (Sony Corporation, Foster City, CA) as a tool for use in the rehabilitation of patients with severe burns. Intensive occupational and physical therapy is crucial in minimizing and preventing long-term disability for the burn patient; however, the therapist faces a difficult challenge combating the agonizing pain experienced by the patient during therapy. The Sony PlayStation II EyeToy is a projected, video-capture system that, although initially developed as a gaming environment for children, may be a useful application in a rehabilitative context. As compared with other virtual reality systems the EyeToy is an efficient rehabilitation tool that is sold commercially at a relatively low cost. This report presents the potential advantages for use of the EyeToy as an innovative rehabilitative tool with mitigating effects on pain in burn rehabilitation. This new technology represents a challenging and motivating way for the patient to immerse himself or herself in an alternate reality while undergoing treatment, thereby reducing the pain and discomfort he or she experiences. This simple, affordable technique may prove to heighten the level of patient cooperation and therefore speed the process of rehabilitation and return of functional ability.
Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.
LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W
2017-02-27
Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.
Big Crater as Viewed by Pathfinder Lander - Anaglyph
NASA Technical Reports Server (NTRS)
1997-01-01
The 'Big Crater' is actually a relatively small Martian crater to the southeast of the Mars Pathfinder landing site. It is 1500 meters (4900 feet) in diameter, or about the same size as Meteor Crater in Arizona. Superimposed on the rim of Big Crater (the central part of the rim as seen here) is a smaller crater nicknamed 'Rimshot Crater.' The distance to this smaller crater, and the nearest portion of the rim of Big Crater, is 2200 meters (7200 feet). To the right of Big Crater, south from the spacecraft, almost lost in the atmospheric dust 'haze,' is the large streamlined mountain nicknamed 'Far Knob.' This mountain is over 450 meters (1480 feet) tall, and is over 30 kilometers (19 miles) from the spacecraft. Another, smaller and closer knob, nicknamed 'Southeast Knob' can be seen as a triangular peak to the left of the flanks of the Big Crater rim. This knob is 21 kilometers (13 miles) southeast from the spacecraft.
The larger features visible in this scene - Big Crater, Far Knob, and Southeast Knob - were discovered on the first panoramas taken by the IMP camera on the 4th of July, 1997, and subsequently identified in Viking Orbiter images taken over 20 years ago. The scene includes rocky ridges and swales or 'hummocks' of flood debris that range from a few tens of meters away from the lander to the distance of South Twin Peak. The largest rock in the nearfield, just left of center in the foreground, nicknamed 'Otter', is about 1.5 meters (4.9 feet) long and 10 meters (33 feet) from the spacecraft.This view of Big Crater was produced by combining 6 individual 'Superpan' scenes from the left and right eyes of the IMP camera. Each frame consists of 8 individual frames (left eye) and 7 frames (right eye) taken with different color filters that were enlarged by 500% and then co-added using Adobe Photoshop to produce, in effect, a super-resolution panchromatic frame that is sharper than an individual frame would be.The anaglyph view of Big Crater was produced by combining the left and right eye mosaics (above) by assigning the left eye view to the red color plane and the right eye view to the green and blue color planes (cyan), to produce a stereo anaglyph mosaic. This mosaic can be viewed in 3-D on your computer monitor or in color print form by wearing red-blue 3-D glasses.Mars Pathfinder is the second in NASA's Discovery program of low-cost spacecraft with highly focused science goals. The Jet Propulsion Laboratory, Pasadena, CA, developed and manages the Mars Pathfinder mission for NASA's Office of Space Science, Washington, D.C. JPL is a division of the California Institute of Technology (Caltech). The IMP was developed by the University of Arizona Lunar and Planetary Laboratory under contract to JPL. Peter Smith is the Principal Investigator.Click below to see the left and right views individually. [figure removed for brevity, see original site] Left [figure removed for brevity, see original site] RightIris coloboma in one eye and pigment dispersion syndrome in the fellow eye.
Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M
2013-05-22
We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.
Gandolfi, Stefano A; Ungaro, Nicola; Tardini, Maria Grazia; Ghirardini, Stella; Carta, Arturo; Mora, Paolo
2014-12-01
Prospective long-term analyses of the role of drug-induced mydriasis and laser peripheral iridotomy (LPI) are needed to identify and manage the eyes of patients with pigment dispersion syndrome (PDS) at risk for progressing to ocular hypertension. To assess the 10-year incidence of increased intraocular pressure (IOP) in the 2 eyes of patients with PDS, with 1 eye that underwent LPI and the other that did not. In a randomized clinical trial in the glaucoma research unit at the University Hospital of Parma, Italy, 72 patients with PDS underwent phenylephrine testing. Of these 72 patients, 29 (58 eyes) tested positive for succeeding IOP elevation, and 43 (59 eyes) tested negative. For the 29 high-risk patients (all in both eyes), one eye was randomly assigned to LPI, and the fellow eye was left untreated. For the 43 low-risk patients, the affected eyes were left untreated. An IOP elevation of 5 mm Hg or higher vs baseline (daily phasing) was considered to be a significant increase (ie, an event). In the high-risk group, 3 of 21 eyes that underwent LPI (14.3%) and 13 of 21 untreated eyes (61.9%) showed an increase in IOP of 5 mm Hg or higher during the follow-up period; 4 of 35 low-risk eyes (11.4%) showed a similar increase. Event-free mean (SD) time was 7.99 (0.43) years for high-risk treated eyes, 3.89 (0.68) years for high-risk untreated eyes, and 7.16 (0.23) years for low-risk eyes. The log-rank test showed the following: P < .001 for treated high-risk eyes vs untreated high-risk eyes, P = .74 for treated high-risk eyes vs low-risk eyes, and P < .001 for untreated high-risk eyes vs low-risk eyes. At the end of the 10-year follow-up, (1) approximately one-third of the whole PDS patient population showed an IOP increase of 5 mm Hg or higher in at least 1 eye; (2) phenylephrine testing identified eyes at high risk for developing IOP elevation; and (3) LPI, when performed on high-risk eyes, reduced the rate of IOP elevation to the same level as the low-risk eyes. clinicaltrials.gov Identifier: NCT01053416.
Bonhage, Corinna E; Mueller, Jutta L; Friederici, Angela D; Fiebach, Christian J
2015-07-01
It is widely agreed upon that linguistic predictions are an integral part of language comprehension. Yet, experimental proof of their existence remains challenging. Here, we introduce a new predictive eye gaze reading task combining eye tracking and functional magnetic resonance imaging (fMRI) that allows us to infer the existence and timing of linguistic predictions via anticipatory eye-movements. Participants read different types of word sequences (i.e., regular sentences, meaningless jabberwocky sentences, non-word lists) up to the pre-final word. The final target word was displayed with a temporal delay and its screen position was dependent on the syntactic word category (nouns vs verbs). During the delay, anticipatory eye-movements into the correct target word area were indicative of linguistic predictions. For fMRI analysis, the predictive sentence conditions were contrasted to the non-word condition, with the anticipatory eye-movements specifying differences in timing across conditions. A conjunction analysis of both sentence conditions revealed the neural substrate of word category prediction, namely a distributed network of cortical and subcortical brain regions including language systems, basal ganglia, thalamus, and hippocampus. Direct contrasts between the regular sentence condition and the jabberwocky condition indicate that prediction of word category in meaningless jabberwocky sentences relies on classical left-hemispheric language systems involving Brodman's area 44/45 in the left inferior frontal gyrus, left superior temporal areas, and the dorsal caudate nucleus. Regular sentences, in contrast, allowed for the prediction of specific words. Word-specific predictions were specifically associated with more widely distributed temporal and parietal cortical systems, most prominently in the right hemisphere. Our results support the presence of linguistic predictions during sentence processing and demonstrate the validity of the predictive eye gaze paradigm for measuring syntactic and semantic aspects of linguistic predictions, as well as for investigating their neural substrates. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hadassah, J; Bhuvaneshwari, Namita; Singh, Deepti; Sehgal, P K
2010-01-01
This is a pilot study of 10 eyes of 6 patients. This paper describes the preparation and clinical evaluation of succinylated collagen punctal plugs (SCPP) in the treatment of dry eye syndrome (DES). SCPP were prepared from succinylated collagen with the exact dimensions of the punctum (length 1.5-2.5 mm, diameter 0.2-0.5 mm, water content between 50 and 55%). All the patients were clinically evaluated for best corrected visual acuity (BCVA), tear fluid levels (TFL), protein content, tear fluid osmolarity (TFO), fluorescence staining of the cornea and tear break-up time (TBUT) before and after punctal occlusion with SCPP. TFL improved among all the patients after punctal occlusion with SCPP. BCVA showed improvement in case 4 (right eye/left eye), case 5 (left eye) and case 6 (right eye), who had developed dry eyes due to environmental conditions. Protein content increased on day 7 in all the patients and gradually decreased. TFO decreased on days 3 and 5 in all patients after punctal occlusion with SCPP, and showed the same levels on day 14. TFL, PC, TFO and TBUT showed significant improvement in all the patients after punctal occlusion with SCPP. All patients experienced symptomatic relief after punctal occlusion with SCPP. There was no discomfort, foreign body sensation, plug extrusion, corneal aberration, infection, or formation of pyogenic granuloma with SCPP. SCPP stands as a promising alternative to other punctal plugs in the treatment of DES. Copyright 2010 S. Karger AG, Basel.
Computing Optic Flow with ArduEye Vision Sensor
2013-01-01
processing algorithm that can be applied to the flight control of other robotic platforms. 15. SUBJECT TERMS Optical flow, ArduEye, vision based ...2 Figure 2. ArduEye vision chip on Stonyman breakout board connected to Arduino Mega (8) (left) and the Stonyman vision chips (7...robotic platforms. There is a significant need for small, light , less power-hungry sensors and sensory data processing algorithms in order to control the
ERIC Educational Resources Information Center
Spichtig, Alexandra N.; Hiebert, Elfrieda H.; Vorstius, Christian; Pascoe, Jeffrey P.; Pearson, P. David; Radach, Ralph
2016-01-01
The present study measured the comprehension-based silent reading efficiency of U.S. students in grades 2, 4, 6, 8, 10, and 12. Students read standardized grade-level passages while an eye movement recording system was used to measure reading rate, fixations (eye stops) per word, fixation durations, and regressions (right-to-left eye movements)…
Stimulus-response incompatibility activates cortex proximate to three eye fields
NASA Technical Reports Server (NTRS)
Merriam, E. P.; Colby, C. L.; Thulborn, K. R.; Luna, B.; Olson, C. R.; Sweeney, J. A.
2001-01-01
We used functional magnetic resonance imaging (fMRI) to investigate cortical activation during the performance of three oculomotor tasks that impose increasing levels of cognitive demand. (1) In a visually guided saccade (VGS) task, subjects made saccades to flashed targets. (2) In a compatible task, subjects made leftward and rightward saccades in response to foveal presentation of the uppercase words "LEFT" or "RIGHT." (3) In a mixed task, subjects made rightward saccades in response to the lowercase word "left" and leftward saccades in response to the lowercase word "right" on incompatible trials (60%). The remaining 40% of trials required compatible responses to uppercase words. The VGS and compatible tasks, when compared to fixation, activated the three cortical eye fields: the supplementary eye field (SEF), the frontal eye field (FEF), and the parietal eye field (PEF). The mixed task, when compared to the compatible task, activated three additional cortical regions proximate to the three eye fields: (1) rostral to the SEF in medial frontal cortex; (2) rostral to the FEF in dorsolateral prefrontal cortex (DLPFC); (3) rostral and lateral to the PEF in posterior parietal cortex. These areas may contribute to the suppression of prepotent responses and in holding novel visuomotor associations in working memory. Copyright 2001 Academic Press.
The role of left inferior frontal cortex during audiovisual speech perception in infants.
Altvater-Mackensen, Nicole; Grossmann, Tobias
2016-06-01
In the first year of life, infants' speech perception attunes to their native language. While the behavioral changes associated with native language attunement are fairly well mapped, the underlying mechanisms and neural processes are still only poorly understood. Using fNIRS and eye tracking, the current study investigated 6-month-old infants' processing of audiovisual speech that contained matching or mismatching auditory and visual speech cues. Our results revealed that infants' speech-sensitive brain responses in inferior frontal brain regions were lateralized to the left hemisphere. Critically, our results further revealed that speech-sensitive left inferior frontal regions showed enhanced responses to matching when compared to mismatching audiovisual speech, and that infants with a preference to look at the speaker's mouth showed an enhanced left inferior frontal response to speech compared to infants with a preference to look at the speaker's eyes. These results suggest that left inferior frontal regions play a crucial role in associating information from different modalities during native language attunement, fostering the formation of multimodal phonological categories. Copyright © 2016 Elsevier Inc. All rights reserved.
Lukos, Jamie R.; Snider, Joseph; Hernandez, Manuel E.; Tunik, Eugene; Hillyard, Steven; Poizner, Howard
2013-01-01
The effect of Parkinson’s disease on hand-eye coordination and corrective response control during reach-to-grasp tasks remains unclear. Moderately impaired Parkinson’s disease patients (PD, n=9) and age-matched controls (n=12) reached to and grasped a virtual rectangular object, with haptic feedback provided to the thumb and index fingertip by two 3-degree of freedom manipulanda. The object rotated unexpectedly on a minority of trials, requiring subjects to adjust their grasp aperture. On half the trials, visual feedback of finger positions disappeared during the initial phase of the reach, when feedforward mechanisms are known to guide movement. PD patients were tested without (OFF) and with (ON) medication to investigate the effects of dopamine depletion and repletion on eye-hand coordination online corrective response control. We quantified eye-hand coordination by monitoring hand kinematics and eye position during the reach. We hypothesized that if the basal ganglia are important for eye-hand coordination and online corrections to object perturbations, then PD patients tested OFF medication would show reduced eye-hand spans and impoverished arm-hand coordination responses to the perturbation, which would be further exasperated when visual feedback of the hand was removed. Strikingly, PD patients tracked their hands with their gaze, and their movements became destabilized when having to make online corrective responses to object perturbations exhibiting pauses and changes in movement direction. These impairments largely remained even when tested in the ON state, despite significant improvement on the Unified Parkinson’s Disease Rating Scale. Our findings suggest that basal ganglia-cortical loops are essential for mediating eye-hand coordination and adaptive online responses for reach-to-grasp movements, and that restoration of tonic levels of dopamine may not be adequate to remediate this coordinative nature of basal ganglia modulated function. PMID:24056196
[Iris abscess after bacterial endocarditis in a patient with leukaemia. Differential diagnosis].
Manrique Lipa, R; González Sánchez, E; Asencio Duran, M; Gonzalez-Peramato, P; Fonseca Santodomingo, A
2014-04-01
To report a case of iris abscess due to bacterial endocarditis. A 46-year-old male under diagnosis of promielocitic leukemia and endocarditis presented with decreased vision in left eye (OS). Ophthalmic exploration revealed iris abscess and hypopyon with fibrinous exudate in iris of the left eye and tyndall +1 in right eye (OD). Blood culture and anterior chamber paracentesis was positive for methicillin-sensitive Staphylococcus aureus and negative for blastic cells in citology. Treatment with systemic antibiotic was initiated with total resolution of inflammation. Iris abscess is an unusual septic focus in bacterial endocarditis. It is crucial to rule out an extramedullary metastasis in a patient with leukemia due to the general prognosis. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Saldaña Garrido, J D; Martínez Rubio, M; Carrión Campo, R; Moya Moya, M A; Rico Sergado, L
2017-03-01
A 43-year-old woman in remission from T- cell acute lymphoblastic leukaemia was referred to our hospital with suspected leukaemic retinitis. The funduscopic examination of her left eye revealed multifocal yellow-white peripheral retinitis and retinal haemorrhage. The patient was treated for cytomegalovirus retinitis after an extended haematological investigation showed no abnormalities. Initial improvement was followed by papillitis in the left eye and motility restriction in the right eye. Magnetic resonance and lumbar puncture confirmed leukaemia relapse. Specific treatment was initiated with complete resolution. Ocular involvement may precede haematological leukaemia relapse. Physicians should be alerted when ocular symptoms appear in these cases. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
Endocapsular hematoma: a rare form of ocular hemorrhage after thrombolysis with streptokinase.
Dhawan, Bodhraj; Soni, Rhibhu; Singh, Rajbir; Vig, Vipan
2014-08-01
Endocapsular hematoma has previously been described as a cataract surgery complication more commonly observed in eyes receiving a combined cataract and glaucoma surgery. However, it can also be a rare form of ocular bleed following thrombolysis with streptokinase. A 65-year-old diabetic male presented to us with complain of sudden painless diminution of vision in his left eye, which he developed while he was being thrombolysed with streptokinase administered intravenously for an episode of acute myocardial infarct. On examination, left eye was pseudophakic with collection of blood in the capsular bag (Endocapsular hematoma). Endocapsular hematoma can be a rare form of ocular bleeding complicated by thrombolysis. Reporting this case becomes more relevant in the present era with increasing number of patients suffering from ischemic heart disease and likely to undergo thrombolysis.
Time for a Change; Spirit's View on Sol 1843 (Stereo)
NASA Technical Reports Server (NTRS)
2009-01-01
[figure removed for brevity, see original site] Left-eye view of a color stereo pair for PIA11973 [figure removed for brevity, see original site] Right-eye view of a color stereo pair for PIA11973 NASA's Mars Exploration Rover Spirit used its navigation camera to take the images that have been combined into this stereo, full-circle view of the rover's surroundings during the 1,843rd Martian day, or sol, of Spirit's surface mission (March 10, 2009). South is in the middle. North is at both ends. This view combines images from the left-eye and right-eye sides of the navigation camera. It appears three-dimensional when viewed through red-blue glasses with the red lens on the left. The rover had driven 36 centimeters downhill earlier on Sol 1854, but had not been able to get free of ruts in soft material that had become an obstacle to getting around the northeastern corner of the low plateau called 'Home Plate.' The Sol 1854 drive, following two others in the preceding four sols that also achieved little progress in the soft ground, prompted the rover team to switch to a plan of getting around Home Plate counterclockwise, instead of clockwise. The drive direction in subsequent sols was westward past the northern edge of Home Plate. This view is presented as a cylindrical-perspective projection with geometric seam correction.Prevalence of refractive errors among school children in gondar town, northwest ethiopia.
Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete
2012-10-01
Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment.
Night-Migratory Songbirds Possess a Magnetic Compass in Both Eyes
Lefeldt, Nele; Prior, Helmut; Mouritsen, Henrik
2012-01-01
Previous studies on European robins, Erithacus rubecula, and Australian silvereyes, Zosterops lateralis, had suggested that magnetic compass information is being processed only in the right eye and left brain hemisphere of migratory birds. However, recently it was demonstrated that both garden warblers, Sylvia borin, and European robins have a magnetic compass in both eyes. These results raise the question if the strong lateralization effect observed in earlier experiments might have arisen from artifacts or from differences in experimental conditions rather than reflecting a true all-or-none lateralization of the magnetic compass in European robins. Here we show that (1) European robins having only their left eye open can orient in their seasonally appropriate direction both during autumn and spring, i.e. there are no strong lateralization differences between the outward journey and the way home, that (2) their directional choices are based on the standard inclination compass as they are turned 180° when the inclination is reversed, and that (3) the capability to use the magnetic compass does not depend on monocular learning or intraocular transfer as it is already present in the first tests of the birds with only one eye open. PMID:22984416
AquaLase versus NeoSoniX--a comparison study.
Jiraskova, Nada; Rozsival, Pavel; Kadlecova, Jana; Nekolova, Jana; Pozlerova, Jana; Dubravska, Zlatica
2007-12-01
To compare the metrics and surgical outcome when using Infiniti AquaLase and NeoSoniX cataract removal modalities. This prospective clinical study involved 50 patients with bilateral cataracts and lens removal using AquaLase in the right eye and NeoSoniX in the left eye. Best corrected visual acuity (BCVA), endothelial cell density and pachymetry were evaluted pre- and postoperatively. Statistical analysis was performed using the Wilcoxon Signed- Rank Test. Preoperative mean pachymetry was 569 +/- 31 mu in the right eye (RE) and 560 +/- 37 mu in the left eye (LE), mean endothelial cell density 2744 +/- 418 cells/mm(2) (RE) and 2730 +/- 472 cells/mm(2) (LE). One week after operation pachymetry was 576 +/- 52 mu (RE) and 583 +/- 72 mu (LE) and endothelial cell density 2388 +/- 586 cells/mm(2) (RE) and 2463 +/- 615 cells/mm(2) (LE). One month after surgery pachymetry was 556 +/- 43 mu (RE) and 559 +/- 44 mu (LE) and endothelial cell density 2368 +/- 52 cells/mm(2) (RE) and 2495 +/- 548 cells/mm(2) (LE). BCVA improved in all eyes and was 0.8 or better on the first postoperative day. Both the NeosoniX and AquaLase minimize intraoperative damage to ocular structures.
Enhanced Video-Oculography System
NASA Technical Reports Server (NTRS)
Moore, Steven T.; MacDougall, Hamish G.
2009-01-01
A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.
Eye tracking, strategies, and sex differences in virtual navigation.
Andersen, Nicolas E; Dahmani, Louisa; Konishi, Kyoko; Bohbot, Véronique D
2012-01-01
Reports of sex differences in wayfinding have typically used paradigms sensitive to the female advantage (navigation by landmarks) or sensitive to the male advantage (navigation by cardinal directions, Euclidian coordinates, environmental geometry, and absolute distances). The current virtual navigation paradigm allowed both men and women an equal advantage. We studied sex differences by systematically varying the number of landmarks. Eye tracking was used to quantify sex differences in landmark utilisation as participants solved an eight-arm radial maze task within different virtual environments. To solve the task, participants were required to remember the locations of target objects within environments containing 0, 2, 4, 6, or 8 landmarks. We found that, as the number of landmarks available in the environment increases, the proportion of time men and women spend looking at landmarks and the number of landmarks they use to find their way increases. Eye tracking confirmed that women rely more on landmarks to navigate, although landmark fixations were also associated with an increase in task completion time. Sex differences in navigational behaviour occurred only in environments devoid of landmarks and disappeared in environments containing multiple landmarks. Moreover, women showed sustained landmark-oriented gaze, while men's decreased over time. Finally, we found that men and women use spatial and response strategies to the same extent. Together, these results shed new light on the discrepancy in landmark utilisation between men and women and help explain the differences in navigational behaviour previously reported. Copyright © 2011 Elsevier Inc. All rights reserved.
78 FR 67454 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-12
... his right eye is 20/20, and in his left eye, no light perception. Following an examination in 2013... perception. Following an examination in 2013, his optometrist noted, ``His visual condition is stable and he... small risk of progression, and the added safety concern with commercial vehicle operation.'' Mr. Granby...
Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K
2009-11-01
Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.
Integrating a Motion Base into a CAVE Automatic Virtual Environment: Phase 1
2001-07-01
this, a CAVE system must perform well in the following motion-related areas: visual gaze stability, simulator sickness, realism (or face validity...and performance validity. Visual Gaze Stability Visual gaze stability, the ability to maintain eye fixation on a particular target, depends upon human...reflexes such as the vestibulo-ocular reflex (VOR) and the optokinetic nystagmus (OKN). VOR is a reflex that counter-rotates the eye relative to the
Electroencephalographic changes using virtual reality program: technical note.
Oliveira, Síria Monyelle Silva de; Medeiros, Candice Simões Pimenta de; Pacheco, Thaiana Barbosa Ferreira; Bessa, Nathalia Priscilla Oliveira Silva; Silva, Fernanda Gabrielle Mendonça; Tavares, Nathália Stéphany Araújo; Rego, Isabelle Ananda Oliveira; Campos, Tania Fernandes; Cavalcanti, Fabrícia Azevedo da Costa
2018-03-01
The aim of the study was to describe the technique of an electroencephalographic (EEG) assessment using the Emotiv EPOC® during the performance of a virtual reality motor task and compare theta, alpha, beta and gamma power frequencies between left and right hemispheres. This is technical note in which 9 healthy young subjects were submitted to an evaluation with Emotiv EPOC® during the Nintendo® Wii 'Basic Step' virtual game using the Wii Balance Board (WBB) on a support 13 centimeters high. The Wilcoxon statistical test was applied and pairing between the cerebral hemispheres was performed. Participants had a mean age of 22.55 ± 2.78 years, 77.8% were right-handed, and 22.8% had no experience with the selected virtual game. According to dominancy (right handed n = 7; and left handed n = 2), it was observed that the right-handed individuals showed significantly greater difference in the right hemisphere in the EEG in front region (gamma power in channels AF4, p = 0.028 and F4, p = 0.043) and parietal region (theta and beta power in P8 channel, p = 0.043), while alpha power showed a greater activity in the left hemisphere (P7 channel, p = 0.043). Considering the inter-hemispheric analysis, it was observed that the right hemisphere presented a higher activation potential in the frontal lobe for gamma waves (p = 0.038 for AF3-AF4 channels), and in the temporal lobe for beta and alpha waves (p = 0.021). This study showed that the virtual environment can provide distinct cortical activation patterns considering an inter-hemispheric analysis, highlighting greater activation potential in the right hemisphere.
Cluster of Martian Mesas on Lower Mount Sharp, Sols 1438 and 1439
2016-10-03
The mesa in the center of this scene from the "Murray Buttes" area on Mars' lower Mount Sharp is longer than a football field. It extends more than 361 feet (110 meters) from the left-most outcrop low on the slope to the right side where rock debris is behind a light-toned, dust-covered dune. The panorama combines sets of images taken by the left-eye camera of the Mast Camera (Mastcam) on NASA's Curiosity Mars rover, for the left half of the scene, and by Mastcam's right-eye camera for the right half of the scene. The component images from the left-eye camera were taken on Aug. 22, 2016, during the 1,438th Martian day, or sol, of the rover's work on Mars. The ones from the right-eye camera, which has a telephoto lens, were taken the following day, on Sol 1439. From the rover's position when the component images were taken, the top of the central mesa is about 310 feet (about 95 meters) away and about 52 feet (about 16 meters) above the rover. The relatively flat foreground is part of a geological layer called the Murray formation, which includes lakebed mud deposits. The buttes and mesas rising above this surface are eroded remnants of ancient sandstone that originated when winds deposited sand after lower Mount Sharp had formed. They are capped by material that is relatively resistant to erosion, just as is the case with many similarly shaped buttes and mesas on Earth. The scene is presented with a color adjustment that approximates white balancing, to resemble how the rocks and sand would appear under daytime lighting conditions on Earth. http://photojournal.jpl.nasa.gov/catalog/PIA20842
15. Detail, lower chord connection point on downstream side, showing ...
15. Detail, lower chord connection point on downstream side, showing pinned connection of lower chord eye bars, laced vertical compression member, diagonal eye bar tension members, turnbuckled diagonal counters, and floor beam. Note also timber floor stringers supported by floor beam, and exposed ends of timber deck members visible at left above lower chord eye bar. View to northwest. - Dry Creek Bridge, Spanning Dry Creek at Cook Road, Ione, Amador County, CA
[Virtual reality in ophthalmological education].
Wagner, C; Schill, M; Hennen, M; Männer, R; Jendritza, B; Knorz, M C; Bender, H J
2001-04-01
We present a computer-based medical training workstation for the simulation of intraocular eye surgery. The surgeon manipulates two original instruments inside a mechanical model of the eye. The instrument positions are tracked by CCD cameras and monitored by a PC which renders the scenery using a computer-graphic model of the eye and the instruments. The simulator incorporates a model of the operation table, a mechanical eye, three CCD cameras for the position tracking, the stereo display, and a computer. The three cameras are mounted under the operation table from where they can observe the interior of the mechanical eye. Using small markers the cameras recognize the instruments and the eye. Their position and orientation in space is determined by stereoscopic back projection. The simulation runs with more than 20 frames per second and provides a realistic impression of the surgery. It includes the cold light source which can be moved inside the eye and the shadow of the instruments on the retina which is important for navigational purposes.
Perceptual impairment and psychomotor control in virtual laparoscopic surgery.
Wilson, Mark R; McGrath, John S; Vine, Samuel J; Brewer, James; Defriend, David; Masters, Richard S W
2011-07-01
It is recognised that one of the major difficulties in performing laparoscopic surgery is the translation of two-dimensional video image information to a three-dimensional working area. However, research has tended to ignore the gaze and eye-hand coordination strategies employed by laparoscopic surgeons as they attempt to overcome these perceptual constraints. This study sought to examine if measures related to tool movements, gaze strategy, and eye-hand coordination (the quiet eye) differentiate between experienced and novice operators performing a two-handed manoeuvres task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Twenty-five right-handed surgeons were categorised as being either experienced (having led more than 60 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The 10 experienced and 15 novice surgeons completed the "two-hand manoeuvres" task from the LAP Mentor basic skills learning environment while wearing a gaze registration system. Performance, movement, gaze, and eye-hand coordination parameters were recorded and compared between groups. The experienced surgeons completed the task significantly more quickly than the novices, used significantly fewer movements, and displayed shorter tool paths. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. A more detailed analysis of a difficult subcomponent of the task revealed that experienced operators used a significantly longer aiming fixation (the quiet eye period) to guide precision grasping movements and hence needed fewer grasp attempts. The findings of the study provide further support for the utility of examining strategic gaze behaviour and eye-hand coordination measures to help further our understanding of how experienced surgeons attempt to overcome the perceptual difficulties inherent in the laparoscopic environment.
NASA Astrophysics Data System (ADS)
Beckhaus, Steffi
Virtual Reality aims at creating an artificial environment that can be perceived as a substitute to a real setting. Much effort in research and development goes into the creation of virtual environments that in their majority are perceivable only by eyes and hands. The multisensory nature of our perception, however, allows and, arguably, also expects more than that. As long as we are not able to simulate and deliver a fully sensory believable virtual environment to a user, we could make use of the fully sensory, multi-modal nature of real objects to fill in for this deficiency. The idea is to purposefully integrate real artifacts into the application and interaction, instead of dismissing anything real as hindering the virtual experience. The term virtual reality - denoting the goal, not the technology - shifts from a core virtual reality to an “enriched” reality, technologically encompassing both the computer generated and the real, physical artifacts. Together, either simultaneously or in a hybrid way, real and virtual jointly provide stimuli that are perceived by users through their senses and are later formed into an experience by the user's mind.
Ocular Manifestations of Oblique Facial Clefts
Ortube, Maria Carolina; Dipple, Katrina; Setoguchi, Yoshio; Kawamoto, Henry K.; Demer, Joseph L.
2014-01-01
Introduction In the Tessier classification, craniofacial clefts are numbered from 0 to 14 and extend along constant axes through the eyebrows, eyelids, maxilla, nostrils, and the lips. We studied a patient with bilateral cleft 10 associated with ocular abnormalities. Method Clinical report with orbital and cranial computed tomography. Results After pregnancy complicated by oligohydramnios, digoxin, and lisinopril exposure, a boy was born with facial and ocular dysmorphism. Examination at age 26 months showed bilateral epibulbar dermoids, covering half the corneal surface, and unilateral morning glory anomaly of the optic nerve. Ductions of the right eye were normal, but the left eye had severely impaired ductions in all directions, left hypotropia, and esotropia. Under anesthesia, the left eye could not be rotated freely in any direction. Bilateral Tessier cleft number 10 was implicated by the presence of colobomata of the middle third of the upper eyelids and eyebrows. As the cleft continued into the hairline, there was marked anterior scalp alopecia. Computed x-ray tomography showed a left middle cranial fossa arachnoid cyst and calcification of the reflected tendon of the superior oblique muscle, trochlea, and underlying sclera, with downward and lateral globe displacement. Discussion Tessier 10 clefts are very rare and usually associated with encephalocele. Bilateral 10 clefts have not been reported previously. In this case, there was coexisting unilateral morning glory anomaly and arachnoid cyst of the left middle cranial fossa but no encephalocele. Conclusions Bilateral Tessier facial cleft 10 may be associated with alopecia, morning glory anomaly, epibulbar dermoids, arachnoid cyst, and restrictive strabismus. PMID:20856062
Sex differences in left/right confusion.
Jordan, Kirsten; Wüstenberg, Torsten; Jaspers-Feyer, Fern; Fellbrich, Anja; Peters, Michael
2006-01-01
In agreement with the literature, females (n=269) gave themselves significantly poorer ratings than males (n=164) in evaluating their ability to make fast and accurate left/right judgments. In order to evaluate the ecological validity of the self-ratings, subjects were tested on a task that required fast and accurate left/right judgments, on a mental rotation task, and on a task that required navigation of a virtual maze. The correlations between the performances and self-ratings were computed. Both males and females who gave themselves very poor LRC (left/right confusion) ratings had significantly lower accuracy scores on the left/right judgement task than males and females with average ratings, but there was no sex-specific relation between LRC ratings and left/right judgements that would explain why females give themselves lower LRC ratings. For females only, a weak correlation between LRC scores and the learning of the virtual maze was observed, but no significant correlations were observed between LRC scores and mental rotation performance. We conclude that self-ratings on left/right confusion questions, although they yield reliable sex differences, are poor predictors of actual performance on spatial tasks that involve left/right judgements. Thus, and in support of earlier speculations (Sholl and Egeth, 1981; Teng and Lee, 1982; Williams et al., 1993), the principal cause of the marked sex differences in LRC self-ratings likely lies in a greater willingness of females to rate themselves more poorly on questions of this type than is the case for men.
Murakami, Tomoaki; Ueda-Arakawa, Naoko; Nishijima, Kazuaki; Uji, Akihito; Horii, Takahiro; Ogino, Ken; Yoshimura, Nagahisa
2014-03-28
To integrate parameters on spectral-domain optical coherence tomography (SD-OCT) in diabetic retinopathy (DR) based on the self-organizing map and objectively describe the macular morphologic patterns. A total of 336 consecutive eyes of 216 patients with DR for whom clear SD-OCT images were available were retrospectively reviewed. Eleven OCT parameters and the logarithm of the minimal angle of resolution (logMAR) were measured. These multidimensional data were analyzed based on the self-organizing map on which similar cases were near each other according to the degree of their similarities, followed by the objective clustering. Self-organizing maps indicated that eyes with greater retinal thickness in the central subfield had greater thicknesses in the superior and temporal subfields. Eyes with foveal serous retinal detachment (SRD) had greater thickness in the nasal or inferior subfield. Eyes with foveal cystoid spaces were arranged to the left upper corner on the two-dimensional map; eyes with foveal SRD to the left lower corner; eyes with thickened retinal parenchyma to the lower area. The following objective clustering demonstrated the unsupervised pattern recognition of macular morphologies in diabetic macular edema (DME) as well as the higher-resolution discrimination of DME per se. Multiple regression analyses showed better association of logMAR with retinal thickness in the inferior subfield in eyes with SRD and with external limiting membrane disruption in eyes with foveal cystoid spaces or thickened retinal parenchyma. The self-organizing map facilitates integrative understanding of the macular morphologic patterns and the structural/functional relationship in DR.
Ethambutol/Linezolid Toxic Optic Neuropathy.
Libershteyn, Yevgeniya
2016-02-01
To report a rare toxic optic neuropathy after long-term use of two medications: ethambutol and linezolid. A 65-year-old man presented to the Miami Veterans Affairs Medical Center in December 2014 for evaluation of progressive vision decrease in both eyes. The patient presented with best-corrected visual acuities of 20/400 in the right eye and counting fingers at 5 feet in the left eye. Color vision was significantly reduced in both eyes. Visual fields revealed a cecocentral defect in both eyes. His fundus and optic nerve examination was unremarkable. Because vision continued to decline after discontinuation of ethambutol, linezolid was also discontinued, after which vision, color vision, and visual fields improved. Because of these findings, the final diagnosis was toxic optic neuropathy. Final visual outcome was 20/30 in the right eye and 20/40 in the left eye. Drug-associated toxic optic neuropathy is a rare but vision-threatening condition. Diagnosis is made based on an extensive case history and careful clinical examination. The examination findings include varying decrease in vision, normal pupils and extraocular muscles, and unremarkable fundoscopy, with the possibility of swollen optic discs in the acute stage of the optic neuropathy. Other important findings descriptive of toxic optic neuropathy include decreased color vision and cecocentral visual field defects. This case illustrates the importance of knowledge of all medications and/or substances a patient consumes that may cause a toxic reaction and discontinuing them immediately if the visual functions are worsening or not improving.
Oscillopsia in "inverse latent" infantile nystagmus syndrome.
Abel, Larry A; Malesic, Linda A
2007-11-01
A possibly unique individual with infantile nystagmus syndrome presented with incessant oscillopsia but good stereopsis when viewing binocularly; her nystagmus was greatly reduced with left eye occlusion. We have attempted to explain this and to identify an intervention that preserves binocular vision while maximizing perceptual stability. Eye movements were recorded and analyzed for duration of foveation (% time when the target was on or near the fovea and the eye was moving at < or = 4 degrees /sec) under different viewing conditions. Changes in foveation were compared with the patient's reports of her perceptual stability. In her right gaze null with her right eye fixating, foveation was 52.9%. This fell to 32.3% for the same eye in primary position and to 0.8% when viewing binocularly in primary position. When viewing binocularly oscillopsia was incessant; when viewing with her right eye vision was stable except in left gaze. Prism correction of her phoria greatly reduced her oscillopsia when viewing binocularly while preserving stereopsis; foveation went up to 33.7%. The patient's ability to maintain good foveation only when viewing with her right eye forces her to choose between stereopsis and stable vision. This may result from the rare combination of (1) requiring good foveation for oscillopsia suppression and (2) nystagmus deteriorating under the stress of maintaining binocularity. There may be many other infantile nystagmus syndrome patients who do not develop oscillopsia but may suffer sufficient asthenopia from a phoria to exacerbate their nystagmus.
Cortical metabolic activity matches the pattern of visual suppression in strabismus.
Adams, Daniel L; Economides, John R; Sincich, Lawrence C; Horton, Jonathan C
2013-02-27
When an eye becomes deviated in early childhood, a person does not experience double vision, although the globes are aimed at different targets. The extra image is prevented from reaching perception in subjects with alternating exotropia by suppression of each eye's peripheral temporal retina. To test the impact of visual suppression on neuronal activity in primary (striate) visual cortex, the pattern of cytochrome oxidase (CO) staining was examined in four macaques raised with exotropia by disinserting the medial rectus muscles shortly following birth. No ocular dominance columns were visible in opercular cortex, where the central visual field is represented, indicating that signals coming from the central retina in each eye were perceived. However, the border strips at the edges of ocular dominance columns appeared pale, reflecting a loss of activity in binocular cells from disruption of fusion. In calcarine cortex, where the peripheral visual field is represented, there were alternating pale and dark bands resembling ocular dominance columns. To interpret the CO staining pattern, [(3)H]proline was injected into the right eye in two monkeys. In the right calcarine cortex, the pale CO columns matched the labeled proline columns of the right eye. In the left calcarine cortex, the pale CO columns overlapped the unlabeled columns of the left eye in the autoradiograph. Therefore, metabolic activity was reduced in the ipsilateral eye's ocular dominance columns which serve peripheral temporal retina, in a fashion consistent with the topographic organization of suppression scotomas in humans with exotropia.
Rosa, R H; Goldberg, M F; Green, W R
1996-01-01
The authors review the histopathologic findings in the eyes of a patient with multiple retinal angiomas and von Hippel-Lindau disease, who underwent treatment with argon laser photocoagulation with follow-up of more than 20 years. The patient was studied ophthalmoscopically and by fluorescein angiography before and after argon laser photocoagulation of retinal angiomas. The eyes were obtained postmortem, and the central portion of the right eye, including the macula and optic nerve head, was sectioned serially for light microscopy. The pupil-optic nerve segment of the left eye was step-sectioned serially for light microscopy. Histopathologic study of the right eye disclosed mild cystoid macular edema and focal areas of exudation in the midperiphery possibly secondary to irradiation of the head. A 1.5 x 0.3-mm area of residual angioma was present in the nasal peripapillary retina. Superotemporally, four chorioretinal scars were present in one photocoagulated area. These scars were composed of dense fibrous tissue with vascularization and variable retinal pigment epithelium hyperplasia. Large, nonangiomatous vessels within each of the scars were continuous with other retinal vessels. Inferotemporally, two chorioretinal scars were present in one photocoagulated area. Histopathologically, these scars were similar to the superotemporal scars, except that no patent retinal vessels traversed the inferotemporal scars. Neovascularization of the retina was associated with one superotemporal and one inferotemporal scar. No residual angiomatous tissue was present in the supero- or inferotemporal areas. Histopathologic examination of the left eye disclosed extensive vitreous organization and periretinal fibrovascular proliferation, extensive gliosis of the retina, and a 4.5 x 2-mm schisis cavity filled with fibrinous exudate. Three angiomas with variable fibrosis were present in the left eye. Despite a poor clinical course in one eye treated with xenon arc photocoagulation, trans-scleral diathermy, and argon laser photocoagulation, a patient with von Hippel-Lindau disease and multiple retinal angiomas retained good vision in the other eye after successful treatment with argon laser photocoagulation with follow-up of more than 20 years. The amount of regression of angiomatous tissue after photocoagulation varied from lesion to lesion (complete in some; minimal in others). The authors conclude that argon laser photocoagulation of early lesions is effective in ablating smaller ( < or = 3-disc diameter) retinal angiomas.
Ahn, Woojin; Dargar, Saurabh; Halic, Tansel; Lee, Jason; Li, Baichun; Pan, Junjun; Sankaranarayanan, Ganesh; Roberts, Kurt; De, Suvranu
2014-01-01
The first virtual-reality-based simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is developed called the Virtual Translumenal Endoscopic Surgery Trainer (VTESTTM). VTESTTM aims to simulate hybrid NOTES cholecystectomy procedure using a rigid scope inserted through the vaginal port. The hardware interface is designed for accurate motion tracking of the scope and laparoscopic instruments to reproduce the unique hand-eye coordination. The haptic-enabled multimodal interactive simulation includes exposing the Calot's triangle and detaching the gall bladder while performing electrosurgery. The developed VTESTTM was demonstrated and validated at NOSCAR 2013.
Virtual reality 3D headset based on DMD light modulators
NASA Astrophysics Data System (ADS)
Bernacki, Bruce E.; Evans, Allan; Tang, Edward
2014-06-01
We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micromirror devices (DMD). Current methods for presenting information for virtual reality are focused on either polarizationbased modulators such as liquid crystal on silicon (LCoS) devices, or miniature LCD or LED displays often using lenses to place the image at infinity. LCoS modulators are an area of active research and development, and reduce the amount of viewing light by 50% due to the use of polarization. Viewable LCD or LED screens may suffer low resolution, cause eye fatigue, and exhibit a "screen door" or pixelation effect due to the low pixel fill factor. Our approach leverages a mature technology based on silicon micro mirrors delivering 720p resolution displays in a small form-factor with high fill factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high-definition resolution and low power consumption, and many of the design methods developed for DMD projector applications can be adapted to display use. Potential applications include night driving with natural depth perception, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design concept is described in which light from the DMD is imaged to infinity and the user's own eye lens forms a real image on the user's retina resulting in a virtual retinal display.
Effects of topical anaesthetics and repeated tonometry on intraocular pressure.
Jóhannesson, Gauti; Hallberg, Per; Eklund, Anders; Behndig, Anders; Lindén, Christina
2014-03-01
To investigate the effects of repeated measurements of intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) to identify mechanisms contributing to the expected IOP reduction. A prospective, single-centre study with six healthy volunteers. Consecutive repeated series (six measurements/serie/method) were made alternately on both eyes for 1 hr with oxybuprocaine/fluorescein in the right eye and tetracaine in the left. The left eye was Pentacam(®) photographed before and repeatedly for 20 min after the IOP measurements. On a separate occasion, the same volunteers received the same amount of anaesthetic drops for 1 hr but without repeated IOP measurements. A significant IOP reduction occurred with both ART and GAT in the oxybuprocaine-treated eye, -4.4 mmHg and -3.8 mmHg, respectively and with ART in the tetracaine eye, -2.1 mmHg. There was a significant difference in IOP reduction between the oxybuprocaine and tetracaine eyes with ART. There was a significant drop in anterior chamber volume (ACV) immediately after the IOP measurements, -12.6 μl that returned to pretrial level after 2 min. After 1 hr of receiving anaesthetic eye drops (without IOP measurements), the IOP decreased significantly in the oxybuprocaine eye for both ART and GAT, -3.1 and -1.7 mmHg, respectively, but not in the tetracaine eye (p = 0.72). The IOP reduction cannot be explained solely by aqueous humor being pressed out of the anterior chamber. While significant IOP reduction occurred with both tetracaine and oxybuprocaine after repeated mechanical applanation, the IOP reduction was significantly greater with oxybuprocaine. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.
Mumcuoglu, Tarkan; Ozge, Gokhan; Soykut, Bugra; Erdem, Onur; Gunal, Armagan; Acikel, Cengizhan
2015-03-01
Ocular siderosis is a rare sight-threatening complication that occurs after a penetrating ocular injury by an iron-containing foreign body. The purposes of this study were to (i) investigate the histopathology, electrophysiology and iron levels/accumulation in ocular siderosis using an animal (Guinea pig) model and (ii) determine the appropriate timing for follow-up foreign body-removal surgery. Thirty guinea pigs were divided into five groups (n = 6 animals/group). On day-1, an iron body was inserted into the vitreous of the right eye of all animals; the left eyes were left undisturbed and were used as controls. At the end of each week during the 5-week study period, electroretinography (ERG) was performed on all animals in one of the five groups. Each animal in that group was sacrificed, after which both eyes were enucleated for histopathological and pharmacological evaluation of intraocular iron. Accumulated iron levels of study eyes were significantly higher than those of control eyes (135.13 and 13.55 μg/g, respectively, p < 0.01). In addition, there was a significant decrease in electrophysiological responses of study eyes. During the first week, iron levels were higher in study eyes than control eyes, but neither histological iron accumulation nor decreased electrophysiological responses could be detected. By the end of the second week, increased iron accumulation was observed histologically in intraocular tissues, along with signs of retinal toxicity, as verified by decreased electrophysiological responses. The present study indicates that the 14th day after a penetrating eye injury by an iron-containing intraocular foreign body represents a clinically critical threshold, after which structural damage to and functional alterations in ocular tissues occur.
The Benefits and Barriers of Virtual Collaboration among Online Adjuncts
ERIC Educational Resources Information Center
Schieffer, Lori
2016-01-01
Online education is a current trend in higher education. This has left colleges needing to hire more part-time remote adjuncts to fill the fluctuating number of available courses. Because remote online adjuncts are susceptible to isolation, the need has arisen to study the benefits and barriers of virtual collaboration. The purpose of this…
On-demand stereoscopic 3D displays for avionic and military applications
NASA Astrophysics Data System (ADS)
Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank
2010-04-01
High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.
Analysis on the 3D crosstalk in stereoscopic display
NASA Astrophysics Data System (ADS)
Choi, Hee-Jin
2010-11-01
Nowadays, with the rapid progresses in flat panel display (FPD) technologies, the three-dimensional (3D) display is now becoming a next mainstream of display market. Among the various 3D display techniques, the stereoscopic 3D display shows different left/right images for each eye of observer using special glasses and is the most popular 3D technique with the advantages of low price and high 3D resolution. However, current stereoscopic 3D displays suffer with the 3D crosstalk which means the interference between the left eye mage and right eye images since it degrades the quality of 3D image severely. In this paper, the meaning and causes of the 3D crosstalk in stereoscopic 3D display are introduced and the pre-proposed methods of 3D crosstalk measurement vision science are reviewed. Based on them The threshold of 3D crosstalk to realize a 3D display with no degradation is analyzed.
Healing of cornea following an electric burn.
Chaudhry, Tanveer Anjum; Shaikh, Farheen; Ahmad, Khabir
2012-08-01
Electrical injuries have become a significant health problem in developing countries because of increase in access to electricity in the last few decades and lack of adequate safety measures. Electrical injuries of eyes are relatively uncommon. A case report of a rapid and complete corneal healing accompanied by satisfactory visual recovery after an electric burn event in a 20-year-old male is reported. The patient had accidental exposure to high voltage live wire while he was repairing it, resulting in severe ocular and superficial body burn. He was not wearing any protective equipment at the time of injury. On examination, the best-corrected visual acuity was counting fingers in the left eye with severe corneal epithelial loss and diffuse corneal oedema. The patient was treated medically, with a rapid corneal healing and resolution of oedema over the next few days. Visual acuity in the worse eye (left) improved to 20/25 from counting fingers.
Ramonas, Krista M; Freilich, Benjamin D
2003-02-01
To report the clinical findings and management of a case of endogenous endophthalmitis in a patient with bacterial endocarditis presenting with a septic metastasis to the iris. Observational case report. Review of clinical findings and treatment. A 37-year-old intravenous drug user hospitalized with bacterial endocarditis secondary to methicillin-sensitive Staphylococcus aureus bacteremia presented with a painful red left eye, hypopyon, and iris abscess. Roth spots were noted in the fundus of the right eye. Aqueous culture was positive for methicillin-sensitive S aureus. The patient was treated with intravitreal, topical, and intravenous antibiotics. The hypopyon and iris abscess resolved within 2 weeks, and the patient achieved a final visual acuity of 20/25 in the left eye. Septic metastasis to the iris is a rare occurrence. To our knowledge this is the first reported case of an iris abscess secondary to bacterial endocarditis.
Pasteurella canis Isolation following Penetrating Eye Injury: A Case Report.
Rashid, Noor-Khairul; Zam, Zarifah; Mdnoor, Siti-Suraya; Siti-Raihan, Ishak; Azhany, Yaakub
2012-01-01
A 3-year-old boy presented with history of trauma to the left eye after he accidentally injured his eye with a broom stick made up from coconut skewers. There was history of cats as their pets but not dogs. Ocular examination revealed left superonasal conjunctival laceration and scleral perforation with prolapsed vitreous. Fundus examination showed minimal vitreous haemorrhage and flat retina. Conjunctiva swab at the wound site was sent for gram staining, culture, and sensitivity. He underwent scleral suturing, vitreous tap, and intravitreal injection of Ceftazidime and Amikacin. Vitreous tap was sent for gram stained, culture and sensitivity. Postoperatively, he was started empirically on IV Ciprofloxacin 160 mg BD, Guttae Ciprofloxacin, and Guttae Ceftazidime. Conjunctiva swab grew Pasteurella canis which was sensitive to all Beta lactams, Ciprofloxacin, Chloramphenicol, and Aminoglycoside. Post-operative was uneventful, absent signs of endophthalmitis or orbital cellulitis.
Pasteurella canis Isolation following Penetrating Eye Injury: A Case Report
Rashid, Noor-Khairul; Zam, Zarifah; MdNoor, Siti-Suraya; Siti-Raihan, Ishak; Azhany, Yaakub
2012-01-01
A 3-year-old boy presented with history of trauma to the left eye after he accidentally injured his eye with a broom stick made up from coconut skewers. There was history of cats as their pets but not dogs. Ocular examination revealed left superonasal conjunctival laceration and scleral perforation with prolapsed vitreous. Fundus examination showed minimal vitreous haemorrhage and flat retina. Conjunctiva swab at the wound site was sent for gram staining, culture, and sensitivity. He underwent scleral suturing, vitreous tap, and intravitreal injection of Ceftazidime and Amikacin. Vitreous tap was sent for gram stained, culture and sensitivity. Postoperatively, he was started empirically on IV Ciprofloxacin 160 mg BD, Guttae Ciprofloxacin, and Guttae Ceftazidime. Conjunctiva swab grew Pasteurella canis which was sensitive to all Beta lactams, Ciprofloxacin, Chloramphenicol, and Aminoglycoside. Post-operative was uneventful, absent signs of endophthalmitis or orbital cellulitis. PMID:22606491
Luceri, Salvatore; Baksoellah, Zainab; Ilyas, Abbas; Baydoun, Lamis; Melles, Gerrit R J
2016-12-01
To describe a case that developed "interface fluid syndrome" after previous laser in situ keratomileusis (LASIK) because of Fuchs endothelial dystrophy (FED), which was reversed by Descemet membrane endothelial keratoplasty (DMEK). A 58-year-old male patient presented with bilateral visual impairment owing to FED and visually significant cataract. Cataract surgery was carried out in both eyes followed by DMEK in his left eye. After cataract surgery, visual acuity did not improve sufficiently because corneal thickness increased and a fine cleft with interface fluid developed between the LASIK-flap and the residual stromal bed. After uneventful DMEK in his left eye, the fluid resolved within a week and visual acuity improved rapidly. This case demonstrates that "interface fluid syndrome" after LASIK caused by concomitant endothelial dysfunction may be reversed by DMEK allowing fast visual recovery.
Hemorrhagic Retinopathy after Spondylosis Surgery and Seizure.
Kord Valeshabad, Ali; Francis, Andrew W; Setlur, Vikram; Chang, Peter; Mieler, William F; Shahidi, Mahnaz
2015-08-01
To report bilateral hemorrhagic retinopathy in an adult female subject after lumbar spinal surgery and seizure. A 38-year-old woman presented with bilateral blurry vision and spots in the visual field. The patient had lumbar spondylosis surgery that was complicated by a dural tear with persistent cerebrospinal fluid leak. Visual symptoms started immediately after witnessed seizure-like activity. At presentation, visual acuity was 20/100 and 20/25 in the right and left eye, respectively. Dilated fundus examination demonstrated bilateral hemorrhagic retinopathy with subhyaloid, intraretinal, and subretinal involvement. At 4-month follow-up, visual acuity improved to 20/60 and 20/20 in the right and left eye, respectively. Dilated fundus examination and fundus photography showed resolution of retinal hemorrhages in both eyes. The first case of bilateral hemorrhagic retinopathy after lumbar spondylosis surgery and witnessed seizure in an adult was reported. Ophthalmic examination may be warranted after episodes of seizure in adults.
Useful field of view in simulated driving: Reaction times and eye movements of drivers
Seya, Yasuhiro; Nakayasu, Hidetoshi; Yagi, Tadasu
2013-01-01
To examine the spatial distribution of a useful field of view (UFOV) in driving, reaction times (RTs) and eye movements were measured in simulated driving. In the experiment, a normal or mirror-reversed letter “E” was presented on driving images with different eccentricities and directions from the current gaze position. The results showed significantly slower RTs in the upper and upper left directions than in the other directions. The RTs were significantly slower in the left directions than in the right directions. These results suggest that the UFOV in driving may be asymmetrical among the meridians in the visual field. PMID:24349688
NEDE: an open-source scripting suite for developing experiments in 3D virtual environments.
Jangraw, David C; Johri, Ansh; Gribetz, Meron; Sajda, Paul
2014-09-30
As neuroscientists endeavor to understand the brain's response to ecologically valid scenarios, many are leaving behind hyper-controlled paradigms in favor of more realistic ones. This movement has made the use of 3D rendering software an increasingly compelling option. However, mastering such software and scripting rigorous experiments requires a daunting amount of time and effort. To reduce these startup costs and make virtual environment studies more accessible to researchers, we demonstrate a naturalistic experimental design environment (NEDE) that allows experimenters to present realistic virtual stimuli while still providing tight control over the subject's experience. NEDE is a suite of open-source scripts built on the widely used Unity3D game development software, giving experimenters access to powerful rendering tools while interfacing with eye tracking and EEG, randomizing stimuli, and providing custom task prompts. Researchers using NEDE can present a dynamic 3D virtual environment in which randomized stimulus objects can be placed, allowing subjects to explore in search of these objects. NEDE interfaces with a research-grade eye tracker in real-time to maintain precise timing records and sync with EEG or other recording modalities. Python offers an alternative for experienced programmers who feel comfortable mastering and integrating the various toolboxes available. NEDE combines many of these capabilities with an easy-to-use interface and, through Unity's extensive user base, a much more substantial body of assets and tutorials. Our flexible, open-source experimental design system lowers the barrier to entry for neuroscientists interested in developing experiments in realistic virtual environments. Copyright © 2014 Elsevier B.V. All rights reserved.
Predictive encoding of moving target trajectory by neurons in the parabigeminal nucleus
Ma, Rui; Cui, He; Lee, Sang-Hun; Anastasio, Thomas J.
2013-01-01
Intercepting momentarily invisible moving objects requires internally generated estimations of target trajectory. We demonstrate here that the parabigeminal nucleus (PBN) encodes such estimations, combining sensory representations of target location, extrapolated positions of briefly obscured targets, and eye position information. Cui and Malpeli (Cui H, Malpeli JG. J Neurophysiol 89: 3128–3142, 2003) reported that PBN activity for continuously visible tracked targets is determined by retinotopic target position. Here we show that when cats tracked moving, blinking targets the relationship between activity and target position was similar for ON and OFF phases (400 ms for each phase). The dynamic range of activity evoked by virtual targets was 94% of that of real targets for the first 200 ms after target offset and 64% for the next 200 ms. Activity peaked at about the same best target position for both real and virtual targets. PBN encoding of target position takes into account changes in eye position resulting from saccades, even without visual feedback. Since PBN response fields are retinotopically organized, our results suggest that activity foci associated with real and virtual targets at a given target position lie in the same physical location in the PBN, i.e., a retinotopic as well as a rate encoding of virtual-target position. We also confirm that PBN activity is specific to the intended target of a saccade and is predictive of which target will be chosen if two are offered. A Bayesian predictor-corrector model is presented that conceptually explains the differences in the dynamic ranges of PBN neuronal activity evoked during tracking of real and virtual targets. PMID:23365185
A Case Study: Introducing a New Benefit Plan on Campus
ERIC Educational Resources Information Center
Gustin, Karen; Bursic, Paul
2004-01-01
Many higher education institutions are strapped by benefit compensation costs for medical and pharmaceutical insurance, and there are few budget dollars left over for other health benefits, such as dental and eye care. Cornell University faced this dilemma and found voluntary dental and eye care plans to be an excellent solution. This article…
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.
Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios
2017-01-01
To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
[Influence AquaLase at corneal endothelial cells].
Jirásková, N; Rozsíval, P; Ludvíková, M; Burova, M; Nekolová, J
2009-07-01
To assess the effect of the cleaning of the posterior capsule using pulses of balanced salt solution (BSS) on the corneal endothelial cells. This pilot study involves 43 patients with bilateral cataracts having lens removal using torsional phacoemulsification (Ozil, Infiniti, Alcon) and bimanul irrigation/aspiration (I/A). Posterior capsule of the right eye of each patient was cleaned using pulses of BSS (AquaLase, Infiniti, Alcon). Surgery was performed by one of 2 surgeons (NJ, PR), both eyes of each patient was operated on by the same surgeon. Best corrected visual acuity (BCVA), endotelial cell count and pachymetry were evaluated pre- and postoperatively as well as occurence af peri- and postoperative complications. Preoperative mean pachymetry (P) was 566 +/- 45 microm in the right eye (RE) and 562 +/- 42 microm in the left eye (LE), mean endotelial cell count (ECC) 2541 +/- 317 cells/mm2 (RE) and 2567 +/- 311 cells/mm2 (LE). Three months after surgery P was 557 +/- 43 microm (RE) and 558 +/- 45 microm (LE) and ECC 2368 +/- 416 cells/mm2 (RE) and 2396 +/- 417 cells/mm2 (LE). There was no statistical difference in postoperative changes of both corneal parameters between right and left eyes. Best corrected visual acuity improved in all eyes and no peri-or postoperative complications occured. Cleaning of the posterior capsule using AquaLase is safe for corneal endothelial cells.
Desmurget, M; Gréa, H; Grethe, J S; Prablanc, C; Alexander, G E; Grafton, S T
2001-04-15
Reaching movements performed without vision of the moving limb are continuously monitored, during their execution, by feedback loops (designated nonvisual). In this study, we investigated the functional anatomy of these nonvisual loops using positron emission tomography (PET). Seven subjects had to "look at" (eye) or "look and point to" (eye-arm) visual targets whose location either remained stationary or changed undetectably during the ocular saccade (when vision is suppressed). Slightly changing the target location during gaze shift causes an increase in the amount of correction to be generated. Functional anatomy of nonvisual feedback loops was identified by comparing the reaching condition involving large corrections (jump) with the reaching condition involving small corrections (stationary), after subtracting the activations associated with saccadic movements and hand movement planning [(eye-arm-jumping minus eye-jumping) minus (eye-arm-stationary minus eye-stationary)]. Behavioral data confirmed that the subjects were both accurate at reaching to the stationary targets and able to update their movement smoothly and early in response to the target jump. PET difference images showed that these corrections were mediated by a restricted network involving the left posterior parietal cortex, the right anterior intermediate cerebellum, and the left primary motor cortex. These results are consistent with our knowledge of the functional properties of these areas and more generally with models emphasizing parietal-cerebellar circuits for processing a dynamic motor error signal.
Steering Control in a Low-Cost Driving Simulator: A Case for the Role of Virtual Vehicle Cab.
Mecheri, Sami; Lobjois, Régis
2018-04-01
The aim of this study was to investigate steering control in a low-cost driving simulator with and without a virtual vehicle cab. In low-cost simulators, the lack of a vehicle cab denies driver access to vehicle width, which could affect steering control, insofar as locomotor adjustments are known to be based on action-scaled visual judgments of the environment. Two experiments were conducted in which steering control with and without a virtual vehicle cab was investigated in a within-subject design, using cornering and straight-lane-keeping tasks. Driving around curves without vehicle cab information made drivers deviate more from the lane center toward the inner edge in right (virtual cab = 4 ± 19 cm; no cab = 42 ± 28 cm; at the apex of the curve, p < .001) but not in left curves. More lateral deviation from the lane center toward the edge line was also found in driving without the virtual cab on straight roads (virtual cab = 21 ± 28 cm; no cab = 36 ± 27 cm; p < .001), whereas driving stability and presence ratings were not affected. In both experiments, the greater lateral deviation in the no-cab condition led to significantly more time driving off the lane. The findings strongly suggest that without cab information, participants underestimate the distance to the right edge of the car (in contrast to the left edge) and thus vehicle width. This produces considerable differences in the steering trajectory. Providing a virtual vehicle cab must be encouraged for more effectively capturing drivers' steering control in low-cost simulators.
ERIC Educational Resources Information Center
Jordan, Timothy R.; McGowan, Victoria A.; Kurtev, Stoyan; Paterson, Kevin B.
2016-01-01
When reading from left to right, useful information acquired during each fixational pause is widely assumed to extend 14 to 15 characters to the right of fixation but just 3 to 4 characters to the left, and certainly no further than the beginning of the fixated word. However, this leftward extent is strikingly small and seems inconsistent with…
Mind-Reading Ability and Structural Connectivity Changes in Aging.
Cabinio, Monia; Rossetto, Federica; Blasi, Valeria; Savazzi, Federica; Castelli, Ilaria; Massaro, Davide; Valle, Annalisa; Nemni, Raffaello; Clerici, Mario; Marchetti, Antonella; Baglio, Francesca
2015-01-01
The Mind-Reading ability through the eyes is an important component of the affective Theory of Mind (ToM), which allows people to infer the other's mental state from the eye gaze. The aim of the present study was to investigate to which extent age-associated structural brain changes impact this ability and to determine if this association is related to executive functions in elderly subjects. For this purpose, Magnetic Resonance Imaging was used to determine both gray matter and white matter (WM) areas associated with aging. The resulting areas have been included in a subsequent correlation analysis to detect the brain regions whose structure was associated with the Mind-Reading ability through the eyes, assessed with the Italian version of the "Reading the Mind in the Eyes" (RME) test, in a sample of 36 healthy subjects ranging from 24 to 79 years of age. The analysis resulted in three important findings: (1) the performance to the RME test is relatively stable across the decades 20-70 (despite a slight decrease of this ability with aging) and independent from executive functions; (2) structural brain imaging demonstrated the involvement of a great number of cortical ToM areas for the execution of the RME test: the bilateral precentral gyrus, the bilateral posterior insula, the left superior temporal gyrus and the left inferior frontal gyrus, which also showed a significant volume decrease with age; (3) an age and task-related decline in WM connectivity on left fronto-temporal portion of the brain. Our results confirm the age-related structural modifications of the brain and show that these changes have an influence on the Mind-Reading ability through the eyes.
Nagiel, Aaron; Lalane, Robert A; Jen, Joanna C; Kreiger, Allan E
2017-10-12
The aim of this study was to investigate the presenting sign of retinal vasculopathy with cerebral leukoencephalopathy and systemic manifestations, a rare autosomal dominant condition caused by mutations in the TREX1 gene, and to explore the potential efficacy of bevacizumab in preventing capillary occlusions. Observational case report with the use of ultra-widefield fluorescein angiography, optical coherence tomography, and optical coherence tomography angiography. A 31-year-old man with a family history of retinal vasculopathy with cerebral leukoencephalopathy and systemic manifestations presented with a scotoma in his left eye. The visual acuity was 20/20 in both eyes, and his examination was notable for scattered cotton wool spots in the retina of both eyes as well as an area of paracentral acute middle maculopathy in the left eye. Ultra-widefield fluorescein angiography revealed peripheral capillary nonperfusion and vascular leakage corresponding to the cotton wool spots. Spectral domain optical coherence tomography and optical coherence tomography angiography confirmed the presence and distribution of superficial capillary plexus and deep capillary plexus ischemia. Neurologic examination and imaging were normal. A trial of monthly intravitreal bevacizumab injections to the left eye over 6 months resulted in diminished capillary leakage. Retinal vasculopathy with cerebral leukoencephalopathy and systemic manifestations is a rare genetic condition manifested most commonly by cerebral and retinal ischemia. This retinal vasculopathy leads to occlusions of small-caliber retinal vessels in the superficial plexus and deep plexus with resulting cotton wool spots and paracentral acute middle maculopathy, respectively. Recognition of the retinal findings by ophthalmologists and neurologists may avoid unnecessary brain biopsies in diagnosing this rare disorder.
Theory of mind and frontal lobe pathology in schizophrenia: a voxel-based morphometry study.
Hirao, Kazuyuki; Miyata, Jun; Fujiwara, Hironobu; Yamada, Makiko; Namiki, Chihiro; Shimizu, Mitsuaki; Sawamoto, Nobukatsu; Fukuyama, Hidenao; Hayashi, Takuji; Murai, Toshiya
2008-10-01
Impaired ability to infer the mental states of others (theory of mind; ToM) is considered to be a key contributor to the poor social functioning of patients with schizophrenia. Although neuroimaging and lesion studies have provided empirical evidence for the neural basis of ToM ability, including the involvement of several prefrontal and temporal structures, the association between pathology of these structures and ToM impairment in schizophrenia patients is less well understood. To address this issue, we investigated structural brain abnormalities and ToM impairment in patients with schizophrenia, and examined the relationship between them. Twenty schizophrenia patients and 20 age-, sex- and education-matched healthy participants underwent magnetic resonance imaging (MRI) and were examined for ToM ability based on the revised version of the "Reading the Mind in the Eyes" (or Eyes) test [Baron-Cohen, S., Wheelwright, S., Hill, J., Raste, Y., Plumb, I., 2001. The 'Reading the Mind in the Eyes' test revised version: A study with normal adults, and adults with Asperger syndrome or high-functioning autism. J. Child Psychol. Psychiatry 42, 241-251]. Voxel-based morphometry (VBM) was performed to investigate regional brain alterations. Relative to normal controls, schizophrenia patients exhibited gray matter reductions in the dorsomedial prefrontal cortex (DMPFC), left ventrolateral prefrontal cortex (VLPFC), ventromedial prefrontal cortex (VMPFC), anterior cingulate cortex (ACC), right superior temporal gyrus (STG) and right insula. The patients performed poorly on the Eyes test. Importantly, poor performance on the Eyes test was found to be associated with gray matter reduction in the left VLPFC in the patient group. These results suggest that prefrontal cortical reduction, especially in the left VLPFC, is a key pathology underlying the difficulties faced by schizophrenia patients in inferring the mental states of others.
Klevtsova, Ekaterina; Nguyen-Min, Caroline; Lalani, Tania; Carlan, Stephen James; Madruga, Mario
2015-02-01
A posttraumatic carotid cavernous fistula can remain unrecognized and ultimately present with symptoms characteristic for a middle cerebral artery stroke. Progressive neurologic deterioration can occur until the condition is diagnosed and treated. If unrecognized and untreated, permanent damage may result. A 46-year-old white man with the history of a motor vehicle crash 6 months prior presented with complaints of acute onset of expressive aphasia and seizure-like activity for 3 days. On presentation, the patient was noted to have moderate proptosis and chemosis of the left eye. Magnetic resonance imaging of the brain showed an arteriovenous fistula arising from the anterolateral precavernous left internal carotid artery. This was directly communicating with the adjacent cortical veins along the medial aspect of the left temporal lobe, resulting in venous congestion in the left frontal opercular region, the left insula, and subinsular tracks. The patient underwent an intracranial coil embolization of a left carotid cavernous fistula. No complications were encountered, and the patient had near-complete resolution of neurologic deficits and left eye proptosis. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Although posttraumatic carotid cavernous fistula is a rare condition, it is important to be aware of this entity because immediate diagnosis and treatment may improve outcome. Copyright © 2015 Elsevier Inc. All rights reserved.
A 3D character animation engine for multimodal interaction on mobile devices
NASA Astrophysics Data System (ADS)
Sandali, Enrico; Lavagetto, Fabio; Pisano, Paolo
2005-03-01
Talking virtual characters are graphical simulations of real or imaginary persons that enable natural and pleasant multimodal interaction with the user, by means of voice, eye gaze, facial expression and gestures. This paper presents an implementation of a 3D virtual character animation and rendering engine, compliant with the MPEG-4 standard, running on Symbian-based SmartPhones. Real-time animation of virtual characters on mobile devices represents a challenging task, since many limitations must be taken into account with respect to processing power, graphics capabilities, disk space and execution memory size. The proposed optimization techniques allow to overcome these issues, guaranteeing a smooth and synchronous animation of facial expressions and lip movements on mobile phones such as Sony-Ericsson's P800 and Nokia's 6600. The animation engine is specifically targeted to the development of new "Over The Air" services, based on embodied conversational agents, with applications in entertainment (interactive story tellers), navigation aid (virtual guides to web sites and mobile services), news casting (virtual newscasters) and education (interactive virtual teachers).
Retinal endoilluminator toxicity of xenon and light-emitting diode (LED) light source: rabbit model.
Aydin, Bahri; Dinç, Erdem; Yilmaz, S Necat; Altiparmak, U Emrah; Yülek, Fatma; Ertekin, Sevda; Yilmaz, Mustafa; Yakın, Mehmet
2014-09-01
This study evaluates retinal toxicity due to endoillumination with the light-emitting diode (LED) light source in comparison to endoillumination with xenon light source. Twenty-five eyes of 14 New Zealand pigmented rabbits were used in the study. The LED light (Omesis Medical Systems, Turkey) group was composed of 7 right eyes, while the other 7 right eyes constituted the xenon group (420 nm filter, 357mW/cm(2)) (Bright Star; DORC, Zuidland, Netherlands). Eleven untreated left eyes composed the control group. Twenty gauge pars plana incision 1.5 mm behind the limbus was performed in the right eyes. Twenty gauge bullet type fiberoptic endoilluminator was inserted into the eye from the incision without any pars plana vitrectomy. Fiberoptic endoilluminator was placed in such a way that it was directed toward visual streak of the rabbit retina with a 5 mm distance to retinal surface. Endoillumination was then applied for 20 min with a maximum light intensity for LED and xenon light. In left control eyes, no surgical procedure and no endoillumination were performed. One week after the endoillumination procedure, both eyes of the rabbits were enucleated following electroretinography. Sections stained with hematoxylin and eosin to evaluate morphologic changes. Retina tissues were assessed by active caspase-3 staining. There was no difference in the shape of the waveforms recorded in the eyes endoilluminated with LED light and xenon light sources compared to control eyes both before and after endoillumination application (p > 0.05). Microscopic evaluation of the retinas with hematoxylin and eosin staining demonstrated that all study groups have normal histologic properties similar to control group. No apoptosis positive cells were found within all sections in all groups. When the LED light source is used with maximum power and limited duration for endoillumination in rabbit eyes it does not produce phototoxic effects that may be detectable by electrophysiology and histology similar to xenon light.
Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.
2009-01-01
Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306
Registration of an on-axis see-through head-mounted display and camera system
NASA Astrophysics Data System (ADS)
Luo, Gang; Rensing, Noa M.; Weststrate, Evan; Peli, Eli
2005-02-01
An optical see-through head-mounted display (HMD) system integrating a miniature camera that is aligned with the user's pupil is developed and tested. Such an HMD system has a potential value in many augmented reality applications, in which registration of the virtual display to the real scene is one of the critical aspects. The camera alignment to the user's pupil results in a simple yet accurate calibration and a low registration error across a wide range of depth. In reality, a small camera-eye misalignment may still occur in such a system due to the inevitable variations of HMD wearing position with respect to the eye. The effects of such errors are measured. Calculation further shows that the registration error as a function of viewing distance behaves nearly the same for different virtual image distances, except for a shift. The impact of prismatic effect of the display lens on registration is also discussed.
Perceptual Calibration for Immersive Display Environments
Ponto, Kevin; Gleicher, Michael; Radwin, Robert G.; Shin, Hyun Joon
2013-01-01
The perception of objects, depth, and distance has been repeatedly shown to be divergent between virtual and physical environments. We hypothesize that many of these discrepancies stem from incorrect geometric viewing parameters, specifically that physical measurements of eye position are insufficiently precise to provide proper viewing parameters. In this paper, we introduce a perceptual calibration procedure derived from geometric models. While most research has used geometric models to predict perceptual errors, we instead use these models inversely to determine perceptually correct viewing parameters. We study the advantages of these new psychophysically determined viewing parameters compared to the commonly used measured viewing parameters in an experiment with 20 subjects. The perceptually calibrated viewing parameters for the subjects generally produced new virtual eye positions that were wider and deeper than standard practices would estimate. Our study shows that perceptually calibrated viewing parameters can significantly improve depth acuity, distance estimation, and the perception of shape. PMID:23428454
Röck, Tobias; Bartz-Schmidt, Karl Ulrich; Röck, Daniel
2017-01-01
Abstract Rationale: Amniotic membrane transplantation (AMT) has been performed therapeutically in humans for over 100 years. In recent 2 decades AMTs have been used increasingly and successfully to treat various types of ophthalmic indications. Patient concerns: An 83-year-old man was referred to our eye hospital with a refractory neurotrophic deep corneal ulcer of the left eye. Diagnoses: The best-corrected visual acuity of the left eye was 0.5 (0.3 logMAR) and of the right eye was 0.05 (1.3 logMAR), which was caused by a central retinal vein occlusion 5 years previously. In cases of binocular vision, a large amniotic membrane patch can cover the whole cornea, including the optical axis. However, in cases with functional monocular vision, as in the case reported here, the AMT has to be performed without the involvement of the optical axis to ensure vision for the patient. Otherwise the patient would have a massively restricted view like looking through waxed paper for at least 2–4 weeks until the overlay dissolved. Interventions: For this case, an AMT using a modified sandwich technique was applied without involvement of the optic axis to ensure vision for the patient. This case report illustrates this eye's course of healing over time. Outcomes: A reduction in the inflammation and healing of the corneal ulcer could be seen. In addition, the corneal vascularization decreased. Six months after the AMT, a slit-lamp examination revealed stable findings. The best-corrected visual acuity of the left eye had increased to 0.8 (0.1 logMAR). Lessons: To the best of our knowledge, a case report on the management of a neurotrophic deep corneal ulcer with AMT in a patient with functional monocular vision has never been undertaken before. PMID:29390295
GEMINI-TITAN (GT)-3 - WEIGHTLESSNESS EXPERIMENT - AMES RESEARCH CENTER (ARC), CA
1965-03-01
S65-18762 (March 1965) --- Effects of the weightless environment on cell division, the basic growth process for living tissue, will be studied during the Gemini-Titan 3 flight scheduled for March 23, 1965. A spiny black sea urchin (upper left) is stimulated by mild electric shock or potassium chloride. As a result it sheds many thousands of eggs. When fertilized, these eggs become actively dividing cells very similar in basic processes to cells of other animals, including humans. These pictures show stages of cell division. At upper right is a single cell; at lower right cell divisions have produced many cells. Cell photos are magnified about 700 times, and all cells shown are too small to be seen by the naked eye. (Photos at upper right and lower left are of sea urchin eggs. Group of cells at lower right are from a sand dollar, which like the sea urchin, is an Echinoderm. Its eggs are virtually identical and are used interchangeably with those of the sea urchin in NASA Ames Center weightlessness experiments.) The Gemini experiment will involve cell division like that shown here. This will take place during several hours of weightlessness aboard the Gemini spacecraft. The experiment will be flown back to laboratories at Cape Kennedy after spacecraft recovery. It has been designed so that any abnormal cell division found by postflight analysis should suggest that the weightless environment has effects on individual cells. This might mean hazards for prolonged periods of manned spaceflight.
Pataky, T C; Lamb, P F
2018-06-01
External randomness exists in all sports but is perhaps most obvious in golf putting where robotic putters sink only 80% of 5 m putts due to unpredictable ball-green dynamics. The purpose of this study was to test whether physical randomness training can improve putting performance in novices. A virtual random-physics golf-putting game was developed based on controlled ball-roll data. Thirty-two subjects were assigned a unique randomness gain (RG) ranging from 0.1 to 2.0-times real-world randomness. Putter face kinematics were measured in 5 m laboratory putts before and after five days of virtual training. Performance was quantified using putt success rate and "miss-adjustment correlation" (MAC), the correlation between left-right miss magnitude and subsequent right-left kinematic adjustments. Results showed no RG-success correlation (r = -0.066, p = 0.719) but mildly stronger correlations with MAC for face angle (r = -0.168, p = 0.358) and clubhead path (r = -0.302, p = 0.093). The strongest RG-MAC correlation was observed during virtual training (r = -0.692, p < 0.001). These results suggest that subjects quickly adapt to physical randomness in virtual training, and also that this learning may weakly transfer to real golf putting kinematics. Adaptation to external physical randomness during virtual training may therefore help golfers adapt to external randomness in real-world environments.
3D visualization and stereographic techniques for medical research and education.
Rydmark, M; Kling-Petersen, T; Pascher, R; Philip, F
2001-01-01
While computers have been able to work with true 3D models for a long time, the same does not apply to the users in common. Over the years, a number of 3D visualization techniques have been developed to enable a scientist or a student, to see not only a flat representation of an object, but also an approximation of its Z-axis. In addition to the traditional flat image representation of a 3D object, at least four established methodologies exist: Stereo pairs. Using image analysis tools or 3D software, a set of images can be made, each representing the left and the right eye view of an object. Placed next to each other and viewed through a separator, the three dimensionality of an object can be perceived. While this is usually done on still images, tests at Mednet have shown this to work with interactively animated models as well. However, this technique requires some training and experience. Pseudo3D, such as VRML or QuickTime VR, where the interactive manipulation of a 3D model lets the user achieve a sense of the model's true proportions. While this technique works reasonably well, it is not a "true" stereographic visualization technique. Red/Green separation, i.e. "the traditional 3D image" where a red and a green representation of a model is superimposed at an angle corresponding to the viewing angle of the eyes and by using a similar set of eyeglasses, a person can create a mental 3D image. The end result does produce a sense of 3D but the effect is difficult to maintain. Alternating left/right eye systems. These systems (typified by the StereoGraphics CrystalEyes system) let the computer display a "left eye" image followed by a "right eye" image while simultaneously triggering the eyepiece to alternatively make one eye "blind". When run at 60 Hz or higher, the brain will fuse the left/right images together and the user will effectively see a 3D object. Depending on configurations, the alternating systems run at between 50 and 60 Hz, thereby creating a flickering effect, which is strenuous for prolonged use. However, all of the above have one or more drawbacks such as high costs, poor quality and localized use. A fifth system, recently released by Barco Systems, modifies the CrystalEyes system by projecting two superimposed images, using polarized light, with the wave plane of the left image at right angle to that of the right image. By using polarized glasses, each eye will see the appropriate image and true stereographic vision is achieved. While the system requires very expensive hardware, it solves some of the more important problems mentioned above, such as the capacity to use higher frame rates and the ability to display images to a large audience. Mednet has instigated a research project which uses reconstructed models from the central nervous system (human brain and basal ganglia, cortex, dendrites and dendritic spines) and peripheral nervous system (nodes of Ranvier and axoplasmic areas). The aim is to modify the models to fit the different visualization techniques mentioned above and compare a group of users perceived degree of 3D for each technique.
Estimating a just-noticeable difference for ocular comfort in contact lens wearers.
Papas, Eric B; Keay, Lisa; Golebiowski, Blanka
2011-06-21
To estimate the just-noticeable difference (JND) in ocular comfort rating by human, contact lens-wearing subjects using 1 to 100 numerical scales. Ostensibly identical, new contact lenses were worn simultaneously in both eyes by 40 subjects who made individual comfort ratings for each eye using a 100-point numerical ratings scale (NRS). Concurrently, interocular preference was indicated on a five-point Likert scale (1 to 5: strongly prefer right, slightly prefer right, no preference, slightly prefer left, strongly prefer left, respectively). Differences in NRS comfort score (ΔC) between the right and left eyes were determined for each Likert scale preference criteria. The distribution of group ΔC scores was examined relative to alternative definitions of JND as a means of estimating its value. For Likert scores indicating the presence of a slight interocular preference, absolute ΔC ranged from 1 to 30 units with a mean of 7.4 ± 1.3 (95% confidence interval) across all lenses and trials. When there was no Likert scale preference expressed between the eyes, absolute ΔC did not exceed 5 units. For ratings of comfort using a 100-point numerical rating scale, the inter-ocular JND is unlikely to be less than 5 units. The estimate for the average value in the population was approximately 7 to 8 units. These numbers indicate the lowest level at which changes in comfort measured with such scales are likely to be clinically significant.
Prevalence of Refractive Errors Among School Children in Gondar Town, Northwest Ethiopia
Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete
2012-01-01
Purpose: Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. Materials and Methods: This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. Results: The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Conclusions: Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment. PMID:23248538
A case of oculo-cerebral B-cell lymphoma in a cat.
Giordano, Cristina; Giudice, Chiara; Bellino, Claudio; Borrelli, Antonio; D'Angelo, Antonio; Gianella, Paola
2013-01-01
To describe a case of a cat with primary B-cell lymphoma affecting the eye and brain and which shared features similar to oculo-cerebral lymphoma in humans. A 13-year-old castrated male Persian cat presented with clinical signs of anterior uveitis and increased intraocular pressure (IOP) in the left eye (OS). A complete diagnostic work-up was declined, and left-eye enucleation was performed. The globe was submitted for histopathology. One week after surgery, the cat became inappetent, hypothermic, and aggressive. Euthanasia was requested by the owner, and a necropsy was permitted. Histopathology of the enucleated globe revealed an extensive neoplastic infiltration consistent with large-cell lymphoma, affecting the anterior uvea, neuroretina and optic nerve. At necropsy, all organs were unremarkable except for the brain, where there was a neoplastic cell population consistent with that described in the left eye, infiltrated and expanded meninges, and perivascular spaces. Immunohistochemically, the neoplastic cells were positive for B-cell marker (CD20) and negative for T-cell marker (CD3). Histology and immunophenotyping suggested a diagnosis of primary central nervous system and ocular large B-cell lymphoma. The lymphoma in this cat resembled oculo-cerebral lymphoma in humans, sharing similar clinical features and histopathological findings, including the perivascular pattern of neoplastic cell infiltration. To the best of the authors' knowledge, this is the first description of a primary oculo-cerebral B-cell lymphoma in a cat. © 2012 American College of Veterinary Ophthalmologists.
Fernández, C; de Salles, A A; Sears, M E; Morris, R D; Davis, D L
2018-05-22
Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the "Standard Anthropomorphic Mannequin" (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults'. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young. Copyright © 2018. Published by Elsevier Inc.
Optic neuropathy following an altitude exposure.
Steigleman, Allan; Butler, Frank; Chhoeu, Austin; O'Malley, Timothy; Bower, Eric; Giebner, Stephen
2003-09-01
This case report describes a 20-yr-old man who presented with retro-orbital pain and blurred vision in his left eye 3 wk after an altitude exposure in a hypobaric chamber. He was found to have significant deficits in color vision and visual fields consistent with an optic neuropathy in his left eye. The patient was diagnosed with decompression sickness and treated with hyperbaric oxygen with a U.S. Navy Treatment Table VI. All signs and symptoms resolved with a single hyperbaric oxygen treatment but recurred. A head MRI revealed a left frontoethmoid sinus opacity. A concomitant sinusitis was diagnosed. The patient had full resolution of symptoms after a total of four hyperbaric oxygen treatments and antibiotic therapy at 6-wk follow-up. Although a para-infectious etiology for this patient's optic neuropathy cannot be excluded, his history of altitude exposure and significant, rapid response to hyperbaric oxygen treatment strongly implies decompression sickness in this case.
Gadkari, Salil S; Kulkarni, Sucheta R; Kamdar, Rushita R; Deshpande, Madan
2015-01-01
The management of retinopathy of prematurity (ROP) can be challenging in preterm babies with a gestational age <30 weeks, those with very low birth weight and multiple risk factors (eg., oxygen therapy for respiratory distress, sepsis, neonatal jaundice). A premature infant presented with "hybrid" zone 1 disease in the right eye and aggressive posterior ROP in the left eye. Both eyes were adequately treated with laser photocoagulation; however, the eyes deteriorated and progressed to stage 4 ROP. Both eyes eventually underwent intravitreal bevacizumab followed by lens sparing vitrectomy with good anatomical and visual outcome. Anticipation of progression despite laser photocoagulation in certain clinical scenarios, frequent follow-up and timely surgical intervention is paramount.
Human eye haptics-based multimedia.
Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron
2014-01-01
Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.