Chairside multi-unit restoration of a quadrant using the new Cerec 3D software.
Ender, A; Wiedhahn, K; Mörmann, W H
2003-01-01
The new Cerec 3D design software for inlays and partial and full crowns simplifies work when producing several restorations in one session. Quite significant progress has been achieved, in that the entire row of teeth of a quadrant can be acquired completely and displayed by successively overlapping optical impressions. The digital working model of a quadrant in which all preparations are acquired is the result. The restorations can be designed individually and inserted virtually. Thanks to virtual insertion, the proximal contacts to neighboring restorations can be designed perfectly and all restorations finally designed, milled, and inserted in one sitting. This method provides a significant rationalization effect.
Arroyo-Acevedo, Jorge; Franco-Quino, Cesar; Ruiz-Ramirez, Eliberto; Chávez-Asmat, Roberto; Anampa-Guzmán, Andrea; Raéz-González, Ernesto; Cabanillas-Coral, José
2016-01-01
Introduction Allergies are a problem that greatly affects the population, and hence the use of antiallergic medications is fairly widespread. However, these drugs have many adverse effects. The use of medicinal plants could be an option, but they need to be evaluated. Objective This study was designed to evaluate the antiallergic effect of the atomized extract of rhizome of Curcuma longa, flowers of Cordia lutea, and leaves of Annona muricata. Materials and methods Twenty-four New Zealand white albino rabbits were randomized into 2 groups. Group A received the atomized extract diluted in physiological saline (APS) and group B received it diluted in Freund’s adjuvant (FA). Then, the back of each rabbit was divided into 4 quadrants. The A-I quadrant received only physiological saline. The A-I quadrants of each rabbit conformed the PS group. The following 3 quadrants received the APS in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The B-I quadrant received only FA. The B-I quadrants of each rabbit conformed the FA group. The following 3 quadrants received the AFA in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The occurrence of erythema and edema was recorded according to the Draize scoring system and the primary irritation index. After 72 hours, biopsies were performed. Results The AFA group presented significantly less erythema and edema compared to the FA group (P<0.05). The histopathologic evaluation at 72 hours showed normal characteristics in the APS group. Conclusion Considering the clinical and histopathological signs, we conclude that the administration of the atomized extract of rhizome of C. longa, flowers of C. lutea, and leaves of A. muricata lacks antigenic effect but could have an antiallergenic effect in a model of dermal irritation in rabbits. PMID:27877047
Arroyo-Acevedo, Jorge; Franco-Quino, Cesar; Ruiz-Ramirez, Eliberto; Chávez-Asmat, Roberto; Anampa-Guzmán, Andrea; Raéz-González, Ernesto; Cabanillas-Coral, José
2016-01-01
Allergies are a problem that greatly affects the population, and hence the use of antiallergic medications is fairly widespread. However, these drugs have many adverse effects. The use of medicinal plants could be an option, but they need to be evaluated. This study was designed to evaluate the antiallergic effect of the atomized extract of rhizome of Curcuma longa , flowers of Cordia lutea , and leaves of Annona muricata . Twenty-four New Zealand white albino rabbits were randomized into 2 groups. Group A received the atomized extract diluted in physiological saline (APS) and group B received it diluted in Freund's adjuvant (FA). Then, the back of each rabbit was divided into 4 quadrants. The A-I quadrant received only physiological saline. The A-I quadrants of each rabbit conformed the PS group. The following 3 quadrants received the APS in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The B-I quadrant received only FA. The B-I quadrants of each rabbit conformed the FA group. The following 3 quadrants received the AFA in 10 μg/mL, 100 μg/mL, and 1,000 μg/mL, respectively. The occurrence of erythema and edema was recorded according to the Draize scoring system and the primary irritation index. After 72 hours, biopsies were performed. The AFA group presented significantly less erythema and edema compared to the FA group ( P <0.05). The histopathologic evaluation at 72 hours showed normal characteristics in the APS group. Considering the clinical and histopathological signs, we conclude that the administration of the atomized extract of rhizome of C. longa , flowers of C. lutea , and leaves of A. muricata lacks antigenic effect but could have an antiallergenic effect in a model of dermal irritation in rabbits.
ERIC Educational Resources Information Center
Chung, Gregory K. W. K.; Gyllenhammer, Ruth G.; Baker, Eva L.
2011-01-01
In this study, we compared the effects of simulator-based virtual ultrasound scanning practice to classroom-based hands-on ultrasound scanning practice on participants' knowledge of FAST window quadrants and interpretation, and on participants' performance on live patient FAST exams. Twenty-five novice participants were randomly assigned to the…
Underwater Docking of Autonomous Undersea Vehicles Using Optical Terminal Guidance
1997-10-01
simply using a brighter beacon. Scattered light within the field-of-view is imaged almost equally into each of the four quadrants of a photodetector...received by adjacent quadrants a great deal of the forward scattered light can be rejected when the signals from the four quadrants are subsequently...employed to aim the nose of the vehicle at the light source because the illumination is equal in all four quadrants only when the tracker’s optical axis is
Virtual Reality Tumor Resection: The Force Pyramid Approach.
Sawaya, Robin; Bugdadi, Abdulgadir; Azarnoush, Hamed; Winkler-Schwartz, Alexander; Alotaibi, Fahad E; Bajunaid, Khalid; AlZhrani, Gmaan A; Alsideiri, Ghusn; Sabbagh, Abdulrahman J; Del Maestro, Rolando F
2018-06-01
The force pyramid is a novel visual representation allowing spatial delineation of instrument force application during surgical procedures. In this study, the force pyramid concept is employed to create and quantify dominant hand, nondominant hand, and bimanual force pyramids during resection of virtual reality brain tumors. To address 4 questions: Do ergonomics and handedness influence force pyramid structure? What are the differences between dominant and nondominant force pyramids? What is the spatial distribution of forces applied in specific tumor quadrants? What differentiates "expert" and "novice" groups regarding their force pyramids? Using a simulated aspirator in the dominant hand and a simulated sucker in the nondominant hand, 6 neurosurgeons and 14 residents resected 8 different tumors using the CAE NeuroVR virtual reality neurosurgical simulation platform (CAE Healthcare, Montréal, Québec and the National Research Council Canada, Boucherville, Québec). Position and force data were used to create force pyramids and quantify tumor quadrant force distribution. Force distribution quantification demonstrates the critical role that handedness and ergonomics play on psychomotor performance during simulated brain tumor resections. Neurosurgeons concentrate their dominant hand forces in a defined crescent in the lower right tumor quadrant. Nondominant force pyramids showed a central peak force application in all groups. Bimanual force pyramids outlined the combined impact of each hand. Distinct force pyramid patterns were seen when tumor stiffness, border complexity, and color were altered. Force pyramids allow delineation of specific tumor regions requiring greater psychomotor ability to resect. This information can focus and improve resident technical skills training.
Clinical presentation and manual therapy for upper quadrant musculoskeletal conditions
Isabel de-la-Llave-Rincón, Ana; Puentedura, Emilio J; Fernández-de-las-Peñas, César
2011-01-01
In recent years, increased knowledge of the pathogenesis of upper quadrant pain syndromes has translated to better management strategies. Recent studies have demonstrated evidence of peripheral and central sensitization mechanisms in different local pain syndromes of the upper quadrant such as idiopathic neck pain, lateral epicondylalgia, whiplash-associated disorders, shoulder impingement, and carpal tunnel syndrome. Therefore, a treatment-based classification approach where subjects receive matched interventions has been developed and, it has been found that these patients experience better outcomes than those receiving non-matched interventions. There is evidence suggesting that the cervical and thoracic spine is involved in upper quadrant pain. Spinal manipulation has been found to be effective for patients with elbow pain, neck pain, or cervicobrachial pain. Additionally, it is known that spinal manipulative therapy exerts neurophysiological effects that can activate pain modulation mechanisms. This paper exposes some manual therapies for upper quadrant pain syndromes, based on a nociceptive pain rationale for modulating central nervous system including trigger point therapy, dry needling, mobilization or manipulation, and cognitive pain approaches. PMID:23115473
Receiver Architecture for 12.5 Gb/s 16-ary Pulse Position Modulation (PPM) Signaling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendez, A J; Gagliardi, R M; Hernandez, V J
2008-07-11
PPM is a signaling scheme that enables the transmission of multiple bits per symbol [1]. It has found favor in the regime of free space optical communications ('FSO' or 'Lasercom'); however, PPM has yet to be widely applied to fiber optic-based communications. Its limitation in fiber results from the exceedingly high bandwidth requirements needed to electronically process a directly detected pulse, especially as the symbol rate increases and the pulse width correspondingly decreases. As a solution, we introduced the concept of a virtual quadrant receiver for receiving 1.25 Gb/s 4-ary PPM, where photonic processing reduced the number of required electronicmore » components [2]. In this paper, we extend these photonic process techniques to a 16-ary, 12.5 Gb/s (10 Gb/s plus 8B/10B line coding) PPM communications system for fiber optic avionics, wherein much of the receiver processing is enabled by techniques based on planar lightwave circuits (PLCs). The architecture is applicable to higher input data rates and M-ary PPM. In the following, we present the PPM encoding and decoding architectures and numerically simulated results.« less
Characterization of Photoreceivers for LISA
NASA Technical Reports Server (NTRS)
Cervantes, F. Guzman; Livas, J.; Silverberg, R.; Buchanan, E.; Stebbins, R.
2010-01-01
LISA will use quadrant photo receivers as front-end devices for the phase meter measuring the motion of drag-free test masses in both angular orientation and separation. We have set up a laboratory testbed for the characterization of photo receivers. Some of the limiting noise sources have been identified and their contribution has been either measured or determined from the measured data. We have built a photo receiver with a 0.5 mm diameter quadrant photodiode with an equivalent input noise of better than 1.8 pA/(square root of)Hz below 20 MHz and a 3 dB bandwidth of 34 MHz.
Hwang, Ki-Tae; Kim, Jongjin; Kim, Eun-Kyu; Jung, Sung Hoo; Sohn, Guiyun; Kim, Seung Il; Jeong, Joon; Lee, Hyouk Jin; Park, Jin Hyun; Oh, Sohee
2017-07-01
We aimed to investigate the prognostic influence of primary tumor site on the survival of patients with breast cancer. Data of 63,388 patients with primary breast cancer from the Korean Breast Cancer Registry were analyzed. Primary tumor sites were classified into 5 groups: upper outer quadrant, lower outer quadrant, upper inner quadrant, lower inner quadrant (LIQ), and central portion. We analyzed overall survival (OS) and breast cancer-specific survival (BCSS) according to primary tumor site. Central portion and LIQ showed lower survival rates regarding both OS and BCSS compared with the other 3 quadrants (all P < .05) and hazard ratios were 1.267 (95% CI, 1.180-1.360, P < .001) and 1.215 (95% CI, 1.097-1.345, P < .001), respectively. Although central portion showed more unfavorable clinicopathologic features, LIQ showed more favorable features than the other 3 quadrants. Primary tumor site was a significant factor in univariate and multivariate analyses for OS and BCSS (all P < .001). For lymph node-negative patients, LIQ showed a worse OS than the other primary tumor sites in the subgroup with no chemotherapy (P < .001), but that effect disappeared in the subgroup with chemotherapy (P = .058). LIQ showed a worse prognosis despite having more favorable clinicopathologic features than other tumor locations and it was more prominent for lymph node-negative patients who received no chemotherapy. The hypothesis of possible hidden internal mammary node metastasis could be suggested to play a key role in LIQ lesions. Copyright © 2017 Elsevier Inc. All rights reserved.
Effect of local administration of simvastatin on postorthodontic relapse in a rabbit model.
AlSwafeeri, Hani; ElKenany, Walid; Mowafy, Mohamed; Karam, Sahar
2018-06-01
Posttreatment relapse is a major challenging clinical issue. The objective of this study was to evaluate the effect of local administration of simvastatin on posttreatment relapse. Orthodontic tooth movement was induced in 10 white New Zealand rabbits. After 21 days of active tooth movement, the orthodontic appliances were removed, and the experimental teeth were allowed to relapse for 21 days. During the relapse phase, 1 mandibular quadrant received local simvastatin administration, and the other received the control vehicle solution on a weekly basis. Three-dimensional models of the experimental teeth were created to allow the measurement of experimental tooth movement and posttreatment relapse. The animals were killed at the end of the relapse phase for histomorphometric analysis of alveolar bone remodeling. The mean relapse percentages were 75.83% in the quadrant receiving the control vehicle solution and 62.01% in the quadrant receiving simvastatin. Neither the relapse magnitude nor the relapse percentage showed a significant difference between the 2 quadrants. Histomorphometric analyses showed that local simvastatin administration yielded a significant reduction in the area of active bone-resorptive lacunae and a significant increase in newly formed bone area. Although local administration of simvastatin aids in bone remodeling associated with posttreatment relapse by reducing the area of active bone resorption and upregulating bone formation, it did not significantly minimize posttreatment relapse. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wrigley, R. C. (Principal Investigator)
1984-01-01
The Thematic Mapper scene of Sacramento, CA acquired during the TDRSS test was received in TIPS format. Quadrants for both scenes were tested for band-to-band registration using reimplemented block correlation techniques. Summary statistics for band-to-band registrations of TM band combinations for Quadrant 4 of the NE Arkansas scene in TIPS format are tabulated as well as those for Quadrant 1 of the Sacramento scene. The system MTF analysis for the San Francisco scene is completed. The thermal band did not have sufficient contrast for the targets used and was not analyzed.
Iorizzo, Dana B.; Riley, Meghan E.; Hayhoe, Mary; Huxlin, Krystel R.
2011-01-01
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ~80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ~90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. PMID:21414339
Iorizzo, Dana B; Riley, Meghan E; Hayhoe, Mary; Huxlin, Krystel R
2011-05-25
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ∼80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ∼90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. Copyright © 2011 Elsevier Ltd. All rights reserved.
Fan, Zhao; Harris, John
2010-10-12
In a recent study (Fan, Z., & Harris, J. (2008). Perceived spatial displacement of motion-defined contours in peripheral vision. Vision Research, 48(28), 2793-2804), we demonstrated that virtual contours defined by two regions of dots moving in opposite directions were displaced perceptually in the direction of motion of the dots in the more eccentric region when the contours were viewed in the right visual field. Here, we show that the magnitude and/or direction of these displacements varies in different quadrants of the visual field. When contours were presented in the lower visual field, the direction of perceived contour displacement was consistent with that when both contours were presented in the right visual field. However, this illusory motion-induced spatial displacement disappeared when both contours were presented in the upper visual field. Also, perceived contour displacement in the direction of the more eccentric dots was larger in the right than in the left visual field, perhaps because of a hemispheric asymmetry in attentional allocation. Quadrant-based analyses suggest that the pattern of results arises from opposite directions of perceived contour displacement in the upper-left and lower-right visual quadrants, which depend on the relative strengths of two effects: a greater sensitivity to centripetal motion, and an asymmetry in the allocation of spatial attention. Copyright © 2010 Elsevier Ltd. All rights reserved.
Larrosa, Jose M; Polo, Vicente; Ferreras, Antonio; García-Martín, Elena; Calvo, Pilar; Pablo, Luis E
2015-12-01
To compare the diagnostic performance of different segmentations of the nerve fiber layer (NFL) thickness measurements using an artificial neural network and to define the optimal number of sectors with best diagnostic ability for glaucoma diagnosis. A total of 117 glaucoma patients and 123 normal subjects were included in the study. NFL thickness measurements were performed using the Spectralis-OCT (Heidelberg Engineering) to obtain the NFL thickness average; measurements from 2 semicircles, 4 quadrants, and 6, 8, 12, 16, 24, 32, and 64 sectors; and 768 uniformly divided locations around the peripapillary NFL. An artificial neural network evaluation was performed to compare the influence of sector analysis on the diagnostic performance of optical coherence tomography. Receiver operating characteristic curves were used to compare the diagnostic ability of the different segmentation analyses. The 6 sectors divided by the horizontal division of the nasal and temporal quadrants were better than the 6 sectors divided by the vertical line through the superior and inferior quadrants [areas under curve, 0.778; 95% confidence interval (CI), 0.720-0.829 and 0.814; 95% CI, 0.759-0.861, respectively]. In the case of quadrants, clock quadrants (area under curve 0.770; 95% CI, 0.712-0.822) were better than the ISNT (inferior-superior-nasal-temporal) quadrants (area under curve, 0.770; 95% CI, 0.712-0.822; P=0.003). The first segmentation strategy that improved the diagnostic value of 4 ISNT quadrants was the 12-sector analysis (area under curve, 0.845; 95% CI, 0.793-0.889; P=0.001). The 2 best candidate strategies for the OCT report were the 12-sector analysis and the 4 planimetric quadrant (alternatively, the 4 clock quadrants) analysis.
The assessment of virtual reality for human anatomy instruction
NASA Technical Reports Server (NTRS)
Benn, Karen P.
1994-01-01
This research project seeks to meet the objective of science training by developing, assessing, and validating virtual reality as a human anatomy training medium. In ideal situations, anatomic models, computer-based instruction, and cadaver dissection are utilized to augment the traditional methods of instruction. At many institutions, lack of financial resources limits anatomy instruction to textbooks and lectures. However, human anatomy is three dimensional, unlike the one dimensional depiction found in textbooks and the two dimensional depiction found on the computer. Virtual reality is a breakthrough technology that allows one to step through the computer screen into a three dimensional world. This technology offers many opportunities to enhance science education. Therefore, a virtual testing environment of the abdominopelvic region of a human cadaver was created to study the placement of body parts within the nine anatomical divisions of the abdominopelvic region and the four abdominal quadrants.
Chlamydia trachomatis-induced Fitz-Hugh-Curtis syndrome: a case report.
Ekabe, Cyril Jabea; Kehbila, Jules; Njim, Tsi; Kadia, Benjamin Momo; Tendonge, Celestine Ntemlefack; Monekosso, Gottlieb Lobe
2017-01-03
Fitz-Hugh-Curtis syndrome is defined as perihepatitis associated with pelvic inflammatory disease. Chlamydia trachomatis is one of its most common aetiologies. This syndrome usually presents with right upper quadrant abdominal pain mimicking other hepatobiliary and gastrointestinal pathologies, hence, posing a diagnostic dilemma in settings with limited diagnostic tools. A 32 year old African female presented with acute right upper quadrant abdominal pain and vaginal discharge, for which she had previously received treatment in another health center with no improvement. Clinical and laboratory findings were suggestive of Fitz-Hugh-Curtis syndrome. Five days after treatment with oral doxycycline, the patient showed marked clinical improvement. Fitz-Hugh-Curtis syndrome is a common cause of right upper quadrant pain which is often under diagnosed in poor communities. Hence, it should be included as a differential diagnosis in patients presenting with right upper quadrant pain, especially in females of reproductive age.
Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.
Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian J; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F; Chen, Teresa C
2017-06-01
To determine the diagnostic capability of spectral domain optical coherence tomography peripapillary retinal volume (RV) measurements. A total of 156 patients, 89 primary open-angle glaucoma and 67 normal subjects, were recruited. Spectral domain optical coherence tomography peripapillary RV was calculated for 4 quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing primary open-angle glaucoma. The pairwise comparisons of the best ROC curves for RV and retinal nerve fiber layer (RNFL) were performed. The artifact rates were analyzed. Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (P<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (P=0.0033). The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. RV measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable with that of RNFL parameters in glaucoma but with lower artifact rates.
Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma
Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian John; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F.; Chen, Teresa C.
2017-01-01
Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (SD-OCT) peripapillary retinal volume (RV) measurements. Materials and Methods A total of 156 patients, 89 primary open angle (POAG) and 67 normal subjects, were recruited. SD-OCT peripapillary RV was calculated for four quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic (AUROC) curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing POAG. The pairwise comparisons of the best ROC curves for RV and RNFL were performed. The artifact rates were analyzed. Results Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (p<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (p=0.0033).The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. Retinal volume measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. Conclusion Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable to that of RNFL parameters in glaucoma but with lower artifact rates. PMID:28079657
Hsieh, Yen-Ping; Huang, Ying-Chia; Lan, Shou-Jen; Ho, Ching-Sung
2017-09-01
To investigate the relationships between demographic characteristics of the elderly, type of long-term care (LTC) facilities, and the reasons for moving into LTC facilities. Research participants included people aged over 65 years, living in LTC facilities. A total of 1280 questionnaires were distributed to 111 LTC facilities in Taiwan; 480 questionnaires were retrieved, and 232 were included in the valid sample. The study used a non-linear canonical correlation analysis, which assesses the relationships among similar sets of categorical variables. The results showed that the older adults in quadrant I were characterized by being involved in the decision-making regarding the choice of LTC facilities and received economic support from their children. The older adults in quadrant II mainly lived in LTC facilities to receive medical care, whereas those in quadrant III typically included individuals with low income, who did not choose to live in LTC facilities. Furthermore, those in quadrant IV had positive cognitions associated with LTC facilities. We believe that the results of the present study will facilitate policy-making in the field of LTC, provide reference to the practitioners and the older adults, and identify the types of decisions older adults make when moving into LTC facilities, thus assisting older adults to improve their strategies regarding staying in LTC facilities. Geriatr Gerontol Int 2017; 17: 1319-1327. © 2016 Japan Geriatrics Society.
NASA Astrophysics Data System (ADS)
Liu, Zhilong; Wang, Biao; Tong, Weichao
2015-08-01
This paper designs a solar automatic tracking wireless charging system based on the four quadrant photoelectric sensor. The system track the sun's rays automatically in real time to received the maximum energy and wireless charging to the load through electromagnetic coupling. Four quadrant photoelectric sensor responsive to the solar spectrum, the system could get the current azimuth and elevation angle of the light by calculating the solar energy incident on the sensor profile. System driver the solar panels by the biaxial movement mechanism to rotate and tilt movement until the battery plate and light perpendicular to each other. Maximize the use of solar energy, and does not require external power supply to achieve energy self-sufficiency. Solar energy can be collected for portable devices and load wireless charging by close electromagnetic field coupling. Experimental data show that: Four quadrant photoelectric sensor more sensitive to light angle measurement. when track positioning solar light, Azimuth deviation is less than 0.8°, Elevation angle deviation is less than 0.6°. Use efficiency of a conventional solar cell is only 10% -20%.The system uses a Four quadrant dual-axis tracking to raise the utilization rate of 25% -35%.Wireless charging electromagnetic coupling efficiency reached 60%.
First Permanent Molar Restoration Differences between Those with or without Dental Sealants.
ERIC Educational Resources Information Center
Kuthy, Raymond A.; And Others
1990-01-01
The study examined differences in the number of restorations in permanent, posterior teeth for those children receiving dental sealants with cost sharing when compared to children who do not receive sealants. Results indicated a 51 percent reduction in restoration rates for each quadrant sealed. Findings have implications for cost savings and…
Wackers, Gideon; Vandenryt, Thijs; Cornelis, Peter; Kellens, Evelien; Thoelen, Ronald; De Ceuninck, Ward; Losada-Pérez, Patricia; van Grinsven, Bart; Peeters, Marloes; Wagner, Patrick
2014-01-01
In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM). HTM relies on the change in thermal resistance upon binding of the target molecule to the MIP-type receptor. A flow-through sensor cell was developed, which is segmented into four quadrants with a volume of 2.5 μL each, allowing four measurements to be done simultaneously on a single substrate. Verification measurements were conducted, in which all quadrants received a uniform treatment and all four channels exhibited a similar response. Subsequently, measurements were performed in quadrants, which were functionalized with different MIP particles. Each of these quadrants was exposed to the same buffer solution, spiked with different molecules, according to the MIP under analysis. With the flow cell design we could discriminate between similar small organic molecules and observed no significant cross-selectivity. Therefore, the MIP array sensor platform with HTM as a readout technique, has the potential to become a low-cost analysis tool for bioanalytical applications. PMID:24955945
Diagnostic Capability of Peripapillary Retinal Thickness in Glaucoma Using 3D Volume Scans
Simavli, Huseyin; Que, Christian John; Akduman, Mustafa; Rizzo, Jennifer L.; Tsikata, Edem; de Boer, Johannes F.; Chen, Teresa C.
2015-01-01
Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (SD-OCT) peripapillary retinal thickness (RT) measurements from 3-dimensional (3D) volume scans for primary open angle glaucoma (POAG). Design Cross-sectional study. Methods Setting Institutional Study population 156 patients (89 POAG and 67 normal subjects) Observation procedures One eye of each subject was included. SD-OCT peripapillary RT values from 3D volume scans were calculated for four quadrants of three different sized annuli. Peripapillary retinal nerve fiber layer (RNFL) thickness values were also determined. Main outcome measures Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Results The top five RT AUROCs for all glaucoma patients and for a subset of early glaucoma patients were for the inferior quadrant of outer circumpapillary annulus of circular grid (OCA) 1 (0.959, 0.939), inferior quadrant of OCA2 (0.945, 0.921), superior quadrant of OCA1 (0.890, 0.811), inferior quadrant of OCA3 (0.887, 0.854), and superior quadrant of OCA2 (0.879, 0.807). Smaller RT annuli OCA1 and OCA2 consistently showed better diagnostic performance than the larger RT annulus OCA3. For both RNFL and RT measurements, best AUROC values were found for inferior RT OCA1 and OCA2, followed by inferior and overall RNFL thickness. Conclusion Peripapillary RT measurements from 3D volume scans showed excellent diagnostic performance for detecting both glaucoma and early glaucoma patients. Peripapillary RT values have the same or better diagnostic capability compared to peripapillary RNFL thickness measurements, while also having fewer algorithm errors. PMID:25498354
Virtual reality distraction for pain control during periodontal scaling and root planing procedures.
Furman, Elena; Jasinevicius, T Roma; Bissada, Nabil F; Victoroff, Kristin Z; Skillicorn, Robert; Buchner, Marc
2009-12-01
Although pain management during periodontal treatment usually is achieved with anesthesia, alternative methods are available. The authors conducted a study to evaluate the analgesic effect of immersive virtual reality (VR) during periodontal scaling and root planing (SRP) procedures. The authors recruited 38 patients. They used a within-patient/split-mouth design. Patients received SRP under three treatment conditions in three quadrants. The three conditions were control, watching a movie and VR. After each SRP procedure, patients responded to questions about their discomfort and/or pain by using a visual analog scale (VAS) (range, 0 to 10 in which lower numbers indicate less pain or discomfort). The authors also recorded patients' blood pressure (BP) and pulse rate (PR). Patients were asked which of the three treatment modalities they preferred. The mean (+/- standard deviation) VAS scores for five questions pertaining to control, movie and VR were 3.95 +/- 2.1, 2.57 +/- 1.8 and 1.76 +/- 1.4, respectively. Paired t tests revealed that VAS scores were significantly lower during VR compared with the movie (P <.001) and control (P <.001) conditions. Similarly, BP and PR were lowest during VR, followed by the movie and control conditions. Patients reported that they preferred the VR condition. The results of this study suggest that use of immersive VR distraction may be an effective method of pain control during SRP procedures. Practitioners can use immersive VR distraction for pain control during SRP procedures.
Meta-analysis of stratus OCT glaucoma diagnostic accuracy.
Chen, Hsin-Yi; Chang, Yue-Cune
2014-09-01
To evaluate the diagnostic accuracy of glaucoma in different stages, different types of glaucoma, and different ethnic groups using Stratus optical coherence tomography (OCT). We searched MEDLINE to identify available articles on diagnostic accuracy of glaucoma published between January 2004 and December 2011. A PubMed (National Center for Biotechnology Information) search using medical subject headings and keywords was executed using the following terms: "diagnostic accuracy" or "receiver operator characteristic" or "area under curve" or "AUC" and "Stratus OCT" and "glaucoma." The search was subsequently limited to publications in English. The area under a receiver operator characteristic (AUC) curve was used to measure the diagnostic performance. A random-effects model was used to estimate the pooled AUC value of the 17 parameters (average retinal nerve fiber layer thickness, temporal quadrant, superior quadrant, nasal quadrant, inferior quadrant, and 1 to 12 o'clock). Meta-regression analysis was used to check the significance of some important factors: (1) glaucoma severity (five stages), (2) glaucoma types (four types), and (3) ethnicity (four categories). The orders of accuracy among those parameters were as follows: average > inferior > superior > 7 o'clock > 6 o'clock > 11 o'clock > 12 o'clock > 1 o'clock > 5 o'clock > nasal > temporal > 2 o'clock > 10 o'clock > 8 o'clock > 9 o'clock > 4 o'clock > 3 o'clock. After adjusting for the effects of age, glaucoma severity, glaucoma types, and ethnicity, the average retinal nerve fiber layer thickness provided highest accuracy compared with the other parameters of OCT. The diagnostic accuracy in Asian populations was significantly lower than that in whites and the other two ethnic types. Stratus OCT demonstrated good diagnostic capability in differentiating glaucomatous from normal eyes. However, we should be more cautious in applying this instrument in Asian groups in glaucoma management.
Giannobile, W V; Ryan, S; Shih, M S; Su, D L; Kaplan, P L; Chan, T C
1998-02-01
Osteogenic protein-1 (OP-1) is a member of the transforming growth factor beta superfamily and is a potent modulator of osteogenesis and bone cell differentiation. This preclinical study in dogs sought to assess the effects of OP-1 on periodontal wound healing in surgically created critical size Class III furcation defects. Eighteen male beagle dogs were subjected to the creation of bilateral mandibular 5 mm osseous defects. A split-mouth design was utilized which randomly assigned opposing quadrants to control therapy (surgery alone or collagen vehicle) or 1 of 3 ascending concentrations of OP-1 in a collagen vehicle (0.75 mg OP-1/g collagen, 2.5 mg/g, or 7.5 mg/g). Thus, 9 quadrants per test group received OP-1, 9 quadrants per control group received surgery alone, and 9 quadrants received collagen vehicle alone. Test articles were delivered by a surgeon masked to the treatment, and fluorogenic bone labels were injected at specified intervals post-treatment. Eight weeks after defect creation and OP-1 delivery, tissue blocks of the mandibulae were taken for masked histomorphometric analysis to assess parameters of periodontal regeneration (e.g., bone height, bone area, new attachment formation, and percent of defect filled with new bone). Histomorphometry revealed limited evidence of osteogenesis, cementogenesis, and new attachment formation in either vehicle or surgery-alone sites. In contrast, sites treated with all 3 concentrations of OP-1 showed pronounced stimulation of osteogenesis, regenerative cementum, and new attachment formation. Lesions treated with 7.5 mg/g of OP-1 in collagen regenerated 3.9+/-1.7 mm and 6.1+/-3.4 mm2 (mean +/-S.D.) of linear bone height and bone area, respectively. Furthermore, these differences were statistically different from both control therapies for all wound healing parameters (P < 0.0001). No significant increase in tooth root ankylosis was found among the treatment groups when compared to the surgery-alone group. We conclude that OP-1 offers promise as an attractive candidate for treating severe periodontal lesions.
Rolle, Teresa; Manerba, Linda; Lanzafame, Pietro; Grignolo, Federico M
2016-05-01
To evaluate the diagnostic power of the Posterior Pole Asymmetry Analysis (PPAA) from the SPECTRALIS OCT in glaucoma diagnosis and to define the correlation between the visual field sensitivity (VFS) and macular retinal thickness (MRT). 90 consecutive open-angle glaucoma patients and 23 healthy subjects were enrolled. All subjects underwent Visual Field test (Humphrey Field Analyzer, central 24-2 SITA-Standard) and SD-OCT volume scans (SPECTRALIS, Posterior Pole Asymmetry Analysis). The areas under the Receiving Operating Characteristic curve (AROC) were calculated to assess discriminating power for glaucoma, at first considering total MRT values and hemisphere MRT value and then quadrant MRT values from 16 square cells in a 8 x 8 posterior pole retinal thickness map that were averaged for a mean retinal thickness value. Structure function correlation was performed for total values, hemisphere values and for each quadrant compared to the matching central test points of the VF. The AROCs ranged from 0.70 to 0.82 (p < 0.0001), with no significant differences between each other. The highest AROC observed was in inferior nasal quadrant. The VFS showed a strong correlation only with the corresponding MRT value s for quadrant analysis: Superior Temporal (r = 0.33, p = 0.0013), Superior Nasal (r = 0.43, p < 0.0001), Inferior Temporal (r = 0.57, p < 0.0001) and Inferior Nasal (r = 0.55, p < 0.0001). the quadrant analysis showed statistically significant structure-function correlations and may provide additional data for the diagnostic performance of SPECTRALIS OCT.
Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy
2014-12-01
To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Retrospective Case Control Study. Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. The median RNFL thickness was 185.4 (129.5-349.3 μm), 122.3 (109-156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema.
Design of laser monitoring and sound localization system
NASA Astrophysics Data System (ADS)
Liu, Yu-long; Xu, Xi-ping; Dai, Yu-ming; Qiao, Yang
2013-08-01
In this paper, a novel design of laser monitoring and sound localization system is proposed. It utilizes laser to monitor and locate the position of the indoor conversation. In China most of the laser monitors no matter used in labor in an instrument uses photodiode or phototransistor as a detector at present. At the laser receivers of those facilities, light beams are adjusted to ensure that only part of the window in photodiodes or phototransistors received the beams. The reflection would deviate from its original path because of the vibration of the detected window, which would cause the changing of imaging spots in photodiode or phototransistor. However, such method is limited not only because it could bring in much stray light in receivers but also merely single output of photocurrent could be obtained. Therefore a new method based on quadrant detector is proposed. It utilizes the relation of the optical integral among quadrants to locate the position of imaging spots. This method could eliminate background disturbance and acquired two-dimensional spots vibrating data pacifically. The principle of this whole system could be described as follows. Collimated laser beams are reflected from vibrate-window caused by the vibration of sound source. Therefore reflected beams are modulated by vibration source. Such optical signals are collected by quadrant detectors and then are processed by photoelectric converters and corresponding circuits. Speech signals are eventually reconstructed. In addition, sound source localization is implemented by the means of detecting three different reflected light sources simultaneously. Indoor mathematical models based on the principle of Time Difference Of Arrival (TDOA) are established to calculate the twodimensional coordinate of sound source. Experiments showed that this system is able to monitor the indoor sound source beyond 15 meters with a high quality of speech reconstruction and to locate the sound source position accurately.
NASA Astrophysics Data System (ADS)
Wapenaar, C. P. A.; Van der Neut, J.; Thorbecke, J.; Broggini, F.; Slob, E. C.; Snieder, R.
2015-12-01
Imagine one could place seismic sources and receivers at any desired position inside the earth. Since the receivers would record the full wave field (direct waves, up- and downward reflections, multiples, etc.), this would give a wealth of information about the local structures, material properties and processes in the earth's interior. Although in reality one cannot place sources and receivers anywhere inside the earth, it appears to be possible to create virtual sources and receivers at any desired position, which accurately mimics the desired situation. The underlying method involves some major steps beyond standard seismic interferometry. With seismic interferometry, virtual sources can be created at the positions of physical receivers, assuming these receivers are illuminated isotropically. Our proposed method does not need physical receivers at the positions of the virtual sources; moreover, it does not require isotropic illumination. To create virtual sources and receivers anywhere inside the earth, it suffices to record the reflection response with physical sources and receivers at the earth's surface. We do not need detailed information about the medium parameters; it suffices to have an estimate of the direct waves between the virtual-source positions and the acquisition surface. With these prerequisites, our method can create virtual sources and receivers, anywhere inside the earth, which record the full wave field. The up- and downward reflections, multiples, etc. in the virtual responses are extracted directly from the reflection response at the surface. The retrieved virtual responses form an ideal starting point for accurate seismic imaging, characterization and monitoring.
Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy
2014-01-01
Aim: To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Study Design: Retrospective Case Control Study. Subjects and Methods: Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. Results: The median RNFL thickness was 185.4 (129.5–349.3 μm), 122.3 (109–156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. Conclusion: SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema. PMID:25579359
Use of EyeCam for imaging the anterior chamber angle.
Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin
2010-06-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P < 0.05). With gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P < 0.001, McNemar Test), giving an overall sensitivity of 76.2% (95% confidence interval [CI], 54.9%-90.7%), specificity of 80.9% (95%CI, 73.5%-87.3%), and an area under the receiver operating characteristic curve (AUC) of 0.79. The EyeCam showed good agreement with gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.
Virtual Morris task responses in individuals in an abstinence phase from alcohol.
Ceccanti, Mauro; Coriale, Giovanna; Hamilton, Derek A; Carito, Valentina; Coccurello, Roberto; Scalese, Bruna; Ciafrè, Stefania; Codazzo, Claudia; Messina, Marisa Patrizia; Chaldakov, George N; Fiore, Marco
2018-02-01
The present study was aimed at examining spatial learning and memory, in 33 men and 12 women with alcohol use disorder (AUD) undergoing ethanol detoxification, by using a virtual Morris task. As controls, we recruited 29 men and 10 women among episodic drinkers without a history of alcohol addiction or alcohol-related diseases. Elevated latency to the first movement in all trials was observed only in AUD persons; furthermore, control women had longer latencies compared with control men. Increased time spent to reach the hidden platform in the learning phase was found for women of both groups compared with men, in particular during trial 3. As predicted, AUD persons (more evident in men) spent less time in the target quadrant during the probe trial; however, AUD women had longer latencies to reach the platform in the visible condition during trials 6 and 7 that resulted in a greater distance moved. As for the probe trial, men of both groups showed increased virtual locomotion compared with the women of both groups. The present investigation confirms and extends previous studies showing (i) different gender responses in spatial learning tasks, (ii) some alterations due to alcohol addiction in virtual spatial learning, and (iii) differences between AUD men and AUD women in spatial-behaviour-related paradigms.
Seeing the Hidden Lamina: Effects of Exsanguination on the Optic Nerve Head
Tran, Huong; Wallace, Jacob; Zhu, Ziyi; Lucy, Katie A.; Voorhees, Andrew P.; Schmitt, Samantha E.; Bilonick, Richard A.; Schuman, Joel S.; Smith, Matthew A.; Wollstein, Gadi; Sigal, Ian A.
2018-01-01
Purpose To introduce an experimental approach for direct comparison of the primate optic nerve head (ONH) before and after death by exsanguination. Method The ONHs of four eyes from three monkeys were imaged with spectral-domain optical coherence tomography (OCT) before and after exsanguination under controlled IOP. ONH structures, including the Bruch membrane (BM), BM opening, inner limiting membrane (ILM), and anterior lamina cribrosa (ALC) were delineated on 18 virtual radial sections per OCT scan. Thirteen parameters were analyzed: scleral canal at BM opening (area, planarity, and aspect ratio), ILM depth, BM depth; ALC (depth, shape index, and curvedness), and ALC visibility (globally, superior, inferior, nasal, and temporal quadrants). Results All four ALC quadrants had a statistically significant improvement in visibility after exsanguination (overall P < 0.001). ALC visibility increased by 35% globally and by 36%, 37%, 14%, and 4% in the superior, inferior, nasal, and temporal quadrants, respectively. ALC increased 4.1%, 1.9%, and 0.1% in curvedness, shape index, and depth, respectively. Scleral canals increased 7.2%, 25.2%, and 1.1% in area, planarity, and aspect ratio, respectively. ILM and BM depths averaged −7.5% and −55.2% decreases in depth, respectively. Most, but not all, changes were beyond the repeatability range. Conclusions Exsanguination allows for improved lamina characterization, especially in regions typically blocked by shadowing in OCT. The results also demonstrate changes in ONH morphology due to the loss of blood pressure. Future research will be needed to determine whether there are differences in ONH biomechanics before and after exsanguination and what those differences would imply. PMID:29847664
Laser positioning of four-quadrant detector based on pseudo-random sequence
NASA Astrophysics Data System (ADS)
Tang, Yanqin; Cao, Ercong; Hu, Xiaobo; Gu, Guohua; Qian, Weixian
2016-10-01
Nowadays the technology of laser positioning based on four-quadrant detector has the wide scope of the study and application areas. The main principle of laser positioning is that by capturing the projection of the laser spot on the photosensitive surface of the detector, and then calculating the output signal from the detector to obtain the coordinates of the spot on the photosensitive surface of the detector, the coordinate information of the laser spot in the space with respect to detector system which reflects the spatial position of the target object is calculated effectively. Given the extensive application of FPGA technology and the pseudo-random sequence has the similar correlation of white noise, the measurement process of the interference, noise has little effect on the correlation peak. In order to improve anti-jamming capability of the guided missile in tracking process, when the laser pulse emission, the laser pulse period is pseudo-random encoded which maintains in the range of 40ms-65ms so that people of interfering can't find the exact real laser pulse. Also, because the receiver knows the way to solve the pseudo-random code, when the receiver receives two consecutive laser pulses, the laser pulse period can be decoded successfully. In the FPGA hardware implementation process, around each laser pulse arrival time, the receiver can open a wave door to get location information contained the true signal. Taking into account the first two consecutive pulses received have been disturbed, so after receiving the first laser pulse, it receives all the laser pulse in the next 40ms-65ms to obtain the corresponding pseudo-random code.
Chen, Jeon-Hor; Liao, Fuyi; Zhang, Yang; Li, Yifan; Chang, Chia-Ju; Chou, Chen-Pin; Yang, Tsung-Lung; Su, Min-Ying
2017-07-01
Breast cancer occurs more frequently in the upper outer (UO) quadrant, but whether this higher cancer incidence is related to the greater amount of dense tissue is not known. Magnetic resonance imaging acquires three-dimensional volumetric images and is the most suitable among all breast imaging modalities for regional quantification of density. This study applied a magnetic resonance imaging-based method to measure quadrant percent density (QPD), and evaluated its association with the quadrant location of the developed breast cancer. A total of 126 cases with pathologically confirmed breast cancer were reviewed. Only women who had unilateral breast cancer located in a clear quadrant were selected for analysis. A total of 84 women, including 47 Asian women and 37 western women, were included. An established computer-aided method was used to segment the diseased breast and the contralateral normal breast, and to separate the dense and fatty tissues. Then, a breast was further separated into four quadrants using the nipple and the centroid as anatomic landmarks. The tumor was segmented using a computer-aided method to determine its quadrant location. The distribution of cancer quadrant location, the quadrant with the highest QPD, and the proportion of cancers occurring in the highest QPD were analyzed. The highest incidence of cancer occurred in the UO quadrant (36 out of 84, 42.9%). The highest QPD was also noted most frequently in the UO quadrant (31 out of 84, 36.9%). When correlating the highest QPD with the quadrant location of breast cancer, only 17 women out of 84 (20.2%) had breast cancer occurring in the quadrant with the highest QPD. The results showed that the development of breast cancer in a specific quadrant could not be explained by the density in that quadrant, and further studies are needed to find the biological reasons accounting for the higher breast cancer incidence in the UO quadrant. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Charactering lidar optical subsystem using four quadrants method
NASA Astrophysics Data System (ADS)
Tian, Xiaomin; Liu, Dong; Xu, Jiwei; Wang, Zhenzhu; Wang, Bangxin; Wu, Decheng; Zhong, Zhiqing; Xie, Chenbo; Wang, Yingjian
2018-02-01
Lidar is a kind of active optical remote sensing instruments , can be applied to sound atmosphere with a high spatial and temporal resolution. Many parameter of atmosphere can be get by using different inverse algorithm with lidar backscatter signal. The basic setup of a lidar consist of a transmitter and a receiver. To make sure the quality of lidar signal data, the lidar must be calibrated before being used to measure the atmospheric variables. It is really significant to character and analyze lidar optical subsystem because a well equiped lidar optical subsystem contributes to high quality lidar signal data. we pay close attention to telecover test to character and analyze lidar optical subsystem.The telecover test is called four quadrants method consisting in dividing the telescope aperture in four quarants. when a lidar is well configured with lidar optical subsystem, the normalized signal from four qudrants will agree with each other on some level. Testing our WARL-II lidar by four quadrants method ,we find the signals of the four basically consistent with each other both in near range and in far range. But in detail, the signals in near range have some slight distinctions resulting from overlap function, some signals distinctions are induced by atmospheric instability.
Korthauer, L E; Nowak, N T; Frahmand, M; Driscoll, I
2017-01-15
Although effective spatial navigation requires memory for objects and locations, navigating a novel environment may also require considerable executive resources. The present study investigated associations between performance on the virtual Morris Water Task (vMWT), an analog version of a nonhuman spatial navigation task, and neuropsychological tests of executive functioning and spatial performance in 75 healthy young adults. More effective vMWT performance (e.g., lower latency and distance to reach hidden platform, greater distance in goal quadrant on a probe trial, fewer path intersections) was associated with better verbal fluency, set switching, response inhibition, and ability to mentally rotate objects. Findings also support a male advantage in spatial navigation, with sex moderating several associations between vMWT performance and executive abilities. Overall, we report a robust relationship between executive functioning and navigational skill, with some evidence that men and women may differentially recruit cognitive abilities when navigating a novel environment. Copyright © 2016 Elsevier B.V. All rights reserved.
Chan, Siwa; Chen, Jeon-Hor; Li, Shunshan; Chang, Rita; Yeh, Darh-Cherng; Chang, Ruey-Feng; Yeh, Lee-Ren; Kwong, Jessica; Su, Min-Ying
2017-04-17
To investigate the relationship between mammographic density measured in four quadrants of a breast with the location of the occurred cancer. One hundred and ten women diagnosed with unilateral breast cancer that could be determined in one specific breast quadrant were retrospectively studied. Women with previous cancer/breast surgery were excluded. The craniocaudal (CC) and mediolateral oblique (MLO) mammography of the contralateral normal breast were used to separate a breast into 4 quadrants: Upper-Outer (UO), Upper-Inner (UI), Lower-Outer (LO), and Lower-Inner (LI). The breast area (BA), dense area (DA), and percent density (PD) in each quadrant were measured by using the fuzzy-C-means segmentation. The BA, DA, and PD were compared between patients who had cancer occurring in different quadrants. The upper-outer quadrant had the highest BA (37 ± 15 cm 2 ) and DA (7.1 ± 2.9 cm 2 ), with PD = 20.0 ± 5.8%. The order of BA and DA in the 4 separated quadrants were: UO > UI > LO > LI, and almost all pair-wise comparisons showed significant differences. For tumor location, 67 women (60.9%) had tumor in UO, 16 (14.5%) in UI, 7 (6.4%) in LO, and 20 (18.2%) in LI quadrant, respectively. The estimated odds and the 95% confidence limits of tumor development in the UO, UI, LO and LI quadrants were 1.56 (1.06, 2.29), 0.17 (0.10, 0.29), 0.07 (0.03, 0.15), and 0.22 (0.14, 0.36), respectively. In these 4 groups of women, the order of quadrant BA and DA were all the same (UO > UI > LO > LI), and there was no significant difference in BA, DA or PD among them (all p > 0.05). Breast cancer was most likely to occur in the UO quadrant, which was also the quadrant with highest BA and DA; but for women with tumors in other quadrants, the density in that quadrant was not the highest. Therefore, there was no direct association between quadrant density and tumor occurrence.
Angle assessment by EyeCam, goniophotography, and gonioscopy.
Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2012-09-01
To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.
Kim, Sang Jin; Campbell, J Peter; Kalpathy-Cramer, Jayashree; Ostmo, Susan; Jonas, Karyn E; Choi, Dongseok; Chan, R V Paul; Chiang, Michael F
2018-06-01
Presence of plus disease in retinopathy of prematurity is the most critical element in identifying treatment-requiring disease. However, there is significant variability in plus disease diagnosis. In particular, plus disease has been defined as 2 or more quadrants of vascular abnormality, and it is not clear whether it is more reliably and accurately diagnosed by eye-based assessment of overall retinal appearance or by quadrant-based assessment combining grades of 4 individual quadrants. To compare eye-based vs quadrant-based diagnosis of plus disease and to provide insight for ophthalmologists about the diagnostic process. In this multicenter cohort study, we developed a database of 197 wide-angle retinal images from 141 preterm infants from neonatal intensive care units at 9 academic institutions (enrolled from July 2011 to December 2016). Each image was assigned a reference standard diagnosis based on consensus image-based and clinical diagnosis. Data analysis was performed from February 2017 to September 2017. Six graders independently diagnosed each of the 4 quadrants (cropped images) of the 197 eyes (quadrant-based diagnosis) as well as the entire image (eye-based diagnosis). Images were displayed individually, in random order. Quadrant-based diagnosis of plus disease was made when 2 or more quadrants were diagnosed as indicating plus disease by combining grades of individual quadrants post hoc. Intragrader and intergrader reliability (absolute agreement and κ statistic) and accuracy compared with the reference standard diagnosis. Of the 141 included preterm infants, 65 (46.1%) were female and 116 (82.3%) white, and the mean (SD) gestational age was 27.0 (2.6) weeks. There was variable agreement between eye-based and quadrant-based diagnosis among the 6 graders (Cohen κ range, 0.32-0.75). Four graders showed underdiagnosis of plus disease with quadrant-based diagnosis compared with eye-based diagnosis (by McNemar test). Intergrader agreement of quadrant-based diagnosis was lower than that of eye-based diagnosis (Fleiss κ, 0.75 [95% CI, 0.71-0.78] vs 0.55 [95% CI, 0.51-0.59]). The accuracy of eye-based diagnosis compared with the reference standard diagnosis was substantial to near-perfect, whereas that of quadrant-based plus disease diagnosis was only moderate to substantial for each grader. Graders had lower reliability and accuracy using quadrant-based diagnosis combining grades of individual quadrants than with eye-based diagnosis, suggesting that eye-based diagnosis has advantages over quadrant-based diagnosis. This has implications for more precise definitions of plus disease regarding the criterion of 2 or more quadrants, clinical care, computer-based image analysis, and education for all ophthalmologists who manage retinopathy of prematurity.
Digital quadrature phase detection
Smith, James A.; Johnson, John A.
1992-01-01
A system for detecting the phase of a frequency of phase modulated signal that includes digital quadrature sampling of the frequency or phase modulated signal at two times that are one quarter of a cycle of a reference signal apart, determination of the arctangent of the ratio of a first sampling of the frequency or phase modulated signal to the second sampling of the frequency or phase modulated signal, and a determination of quadrant in which the phase determination is increased by 2.pi. when the quadrant changes from the first quadrant to the fourth quadrant and decreased by 2.pi. when the quadrant changes from the fourth quadrant to the first quadrant whereby the absolute phase of the frequency or phase modulated signal can be determined using an arbitrary reference convention.
Digital quadrature phase detection
Smith, J.A.; Johnson, J.A.
1992-05-26
A system for detecting the phase of a frequency or phase modulated signal that includes digital quadrature sampling of the frequency or phase modulated signal at two times that are one quarter of a cycle of a reference signal apart, determination of the arctangent of the ratio of a first sampling of the frequency or phase modulated signal to the second sampling of the frequency or phase modulated signal, and a determination of quadrant in which the phase determination is increased by 2[pi] when the quadrant changes from the first quadrant to the fourth quadrant and decreased by 2[pi] when the quadrant changes from the fourth quadrant to the first quadrant whereby the absolute phase of the frequency or phase modulated signal can be determined using an arbitrary reference convention. 6 figs.
NASA Astrophysics Data System (ADS)
Plescia, S. M.; Sheehan, A. F.; Haines, S. S.; Cook, S. W.; Worthington, L. L.
2016-12-01
The Bighorn Arch Seismic Experiment (BASE) was a combined active- and passive-source seismic experiment designed to image deep structures including the Moho beneath a basement-involved foreland arch. In summer 2010, over 1800 Texan receivers, with 4.5 Hz vertical component geophones, were deployed at 100-m to 1-km spacing in a region spanning the Bighorn Arch and the adjacent Bighorn and Powder River Basins. Twenty explosive sources were used to create seismic energy during a two-week acquisition period. Teleseismic earthquakes and mine blasts were also recorded during this time period. We utilize both virtual source interferometry and traditional reflection processing to better understand the deep crustal features of the region and the Moho. The large number of receivers, compared to the limited, widely spaced (10 - 30 km) active-source shots, makes the data an ideal candidate for virtual source seismic interferometry to increase fold. Virtual source interferometry results in data representing a geometry where receiver locations act as if they were seismic source positions. A virtual source gather, the product of virtual source interferometry, is produced by the cross correlation of one receiver's recording, the reference trace, with the recordings of all other receivers in a given shot gather. The cross correlation is repeated for all shot gathers and the resulting traces are stacked. This process is repeated until a virtual source gather has been determined for every real receiver location. Virtual source gathers can be processed with a standard reflection seismic processing flow to yield a reflection section. Improper static corrections can be detrimental to effective stacking, and determination of proper statics is often difficult in areas of significant contrast such as between basin and mountain areas. As such, a natural synergy exists between virtual source interferometry and modern industry reflection seismic processing, with its emphasis on detailed static correction and dense acquisition geometries.
Liu, Jun; Khattak, Asad J
2017-12-01
Drivers undertaking risky behaviors at highway-rail grade crossings are often severely injured in collisions with trains. Among these behaviors, gate-violation (referring to driving around or through the gates that were activated and lowered by an approaching train) seems to be one of the most dangerous actions a driver might take at a gated crossing; it may compromise the intended safety improvement made by adding gates at crossings. This study develops a nuanced conceptual framework that uses path analysis to explore the contributing factors to gate-violation behaviors and the correlation between gate-violation behaviors and the crash consequence - the driver injury severity. Further, using geo-spatial modeling techniques, this study explores whether the correlates of gate-violation behaviors and their associations with injury severity are stationary across diverse geographic contexts of the United States. Geo-spatial modeling shows that the correlates of gate-violation and its associations with injury severity vary substantially across the United States. Spatial variations in correlates of gate-violation and injury severity are mapped by estimating geographically weighted regressions; the maps can serve as an instrument for screening safety improvements and help identify regions that need safety improvements. For example, the results show that two-quadrant gates are more likely to have gate-violation crashes than four-quadrant gates in Iowa, Illinois, Wisconsin and Minnesota. These states may need to receive more attentions on the enforcement of inhibiting gate-violation at crossings with two-quadrant gates or have the priority over other states to upgrade these crossings to four-quadrant gates if financially feasible. Copyright © 2017. Published by Elsevier Ltd.
An analysis of the characteristics of Indonesian industrial sectors: 2005-2010
NASA Astrophysics Data System (ADS)
Zuhdi, Ubaidillah
2017-10-01
The purpose of the current study is to analyze the characteristics of Indonesian industrial sectors from 2005 through 2010. The study employs the analysis instruments from the Input-Output (IO) analysis, namely the indices of the power of dispersion, and the sensitivity of dispersion. For 2005 and 2010, the study focuses on nine and seventeen industries, respectively. The results show that industry 3, manufacturing, placed the quadrant I on the analysis period. The fact shows that, from 2005 through 2010, the industry had a strong influence on the Indonesian economic activities, and received high impacts from the external aspects. In other words, the industry has great potency for the Indonesian economy. From the results one can also see that sector 4, electricity and gas, included in the quadrant I in 2010. This fact explains that the sector has also great potency for the economic activities of Indonesia. Thus, the Indonesian government should prioritize the industries development.
Autotransplantation of a mandibular third molar: a case report with 5 years of follow-up.
Chagas e Silva, Mauro Henrique; Lacerda, Mariane Floriano Lopes Santos; Chaves, Maria das Graças Afonso Miranda; Campos, Celso Neiva
2013-01-01
This paper describes the autologous transplantation of a mandibular right third molar to replace the residual roots of the second molar in the same quadrant, preserving function and aesthetics. A 5-year clinical and radiographic follow-up was undertaken. After transplantation, the donor tooth received endodontic treatment and placement of calcium hydroxide, which was periodically replaced every 3 months until the filling of the root canals, totalizing a period of 1-year, when apical closure was confirmed. The tooth was in perfect functional and aesthetic conditions 5 years after beginning of treatment. Autotransplantation is a feasible option for replacing missing teeth when a donor tooth is available. The autotransplantation of a right mandibular third molar with compromised function and aesthetics to replace the residual roots resulting from coronal destruction due to extensive carious lesion of the second molar in the same quadrant was a viable treatment alternative.
Prototype Test Results for the Single Photon Detection SLR2000 Satellite Laser Ranging System
NASA Technical Reports Server (NTRS)
Zagwodzki, Thomas W.; McGarry, Jan F.; Degnan, John J.; Cheek, Jack W.; Dunn, Peter J.; Patterson, Don; Donovan, Howard
2004-01-01
NASA's aging Satellite Laser Ranging (SLR) network is scheduled to be replaced over the next few years with a fully automated single photon detection system. A prototype of this new system, called SLR2000, is currently undergoing field trials at the Goddard Space Flight Center in Greenbelt, Maryland to evaluate photon counting techniques and determine system hardware, software, and control algorithm performance levels and limitations. Newly developed diode pumped microchip lasers and quadrant microchannel plate-based photomultiplier tubes have enabled the development of this high repetition rate single photon detection SLR system. The SLR2000 receiver threshold is set at the single photoelectron (pe) level but tracks satellites with an average signal level typically much less than 1 pe. The 2 kHz laser fire rate aids in satellite acquisition and tracking and will enable closed loop tracking by accumulating single photon count statistics in a quadrant detector and using this information to correct for pointing errors. Laser transmitter beamwidths of 10 arcseconds (FWHM) or less are currently being used to maintain an adequate signal level for tracking while the receiver field of view (FOV) has been opened to 40 arcseconds to accommodate point ahead/look behind angular offsets. In the near future, the laser transmitter point ahead will be controlled by a pair of Risley prisms. This will allow the telescope to point behind and enable closure of the receiver FOV to roughly match the transmitter beam divergence. Bandpass filters (BPF) are removed for night tracking operations while 0.2 nm or 1 nm filters are used during daylight operation. Both day and night laser tracking of Low Earth Orbit (LEO) satellites has been achieved with a laser transmitter energy of only 65 microjoules per pulse. Satellite tracking is presently limited to LEO satellites until the brassboard laser transmitter can be upgraded or replaced. Simultaneous tracks have also been observed with NASA s SLR standard, MOBLAS 7, for the purposes of data comparison and identification of biases. Work continues to optimize the receive optics; upgrade or replace the laser transmitter; calibrate the quadrant detector, the point ahead Risley prisms, and event timer verniers; and test normal point generation with SLR2000 data. This paper will report on the satellite tracking results to date, issues yet to be resolved, and future plans for the SLR2000 system.
2012-01-01
Background To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Methods Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was −1.17 diopters (D; SD 0.64; range −0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was −0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of −1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. Results No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). Conclusions The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895 PMID:22621341
Grewal, D S; Brar, G S; Jain, R; Grewal, S P S
2011-05-01
To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm(3), ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.
The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population.
Li, Yuanjun; Miara, Hamza; Ouyang, Pingbo; Jiang, Bing
2018-01-01
To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Fifty-six subjects with a mean spherical equivalent (MSE) of -3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior ( r = -0.335, P = 0.001) and inferior ( r = -0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant ( r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant ( r = -0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE ( r = 0.319, P = 0.001). The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant.
The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population
2018-01-01
Purpose To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Methods Fifty-six subjects with a mean spherical equivalent (MSE) of −3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Results Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior (r = −0.335, P = 0.001) and inferior (r = −0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant (r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant (r = −0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE (r = 0.319, P = 0.001). Conclusions The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant. PMID:29651341
Validation of an improved abnormality insertion method for medical image perception investigations
NASA Astrophysics Data System (ADS)
Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.
2009-02-01
The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.
Bell, J.S.
1959-09-15
An arrangement for the drift tubes in a linear accelerator is described whereby each drift tube acts to shield the particles from the influence of the accelerating field and focuses the particles passing through the tube. In one embodiment the drift tube is splii longitudinally into quadrants supported along the axis of the accelerator by webs from a yoke, the quadrants. webs, and yoke being of magnetic material. A magnetic focusing action is produced by energizing a winding on each web to set up a magnetic field between adjacent quadrants. In the other embodiment the quadrants are electrically insulated from each other and have opposite polarity voltages on adjacent quadrants to provide an electric focusing fleld for the particles, with the quadrants spaced sufficienily close enough to shield the particles within the tube from the accelerating electric field.
Mochizuki, Yuta; Kaneko, Takao; Kawahara, Keisuke; Toyoda, Shinya; Kono, Norihiko; Hada, Masaru; Ikegami, Hiroyasu; Musha, Yoshiro
2017-11-20
The quadrant method was described by Bernard et al. and it has been widely used for postoperative evaluation of anterior cruciate ligament (ACL) reconstruction. The purpose of this research is to further develop the quadrant method measuring four points, which we named four-point quadrant method, and to compare with the quadrant method. Three-dimensional computed tomography (3D-CT) analyses were performed in 25 patients who underwent double-bundle ACL reconstruction using the outside-in technique. The four points in this study's quadrant method were defined as point1-highest, point2-deepest, point3-lowest, and point4-shallowest, in femoral tunnel position. Value of depth and height in each point was measured. Antero-medial (AM) tunnel is (depth1, height2) and postero-lateral (PL) tunnel is (depth3, height4) in this four-point quadrant method. The 3D-CT images were evaluated independently by 2 orthopaedic surgeons. A second measurement was performed by both observers after a 4-week interval. Intra- and inter-observer reliability was calculated by means of intra-class correlation coefficient (ICC). Also, the accuracy of the method was evaluated against the quadrant method. Intra-observer reliability was almost perfect for both AM and PL tunnel (ICC > 0.81). Inter-observer reliability of AM tunnel was substantial (ICC > 0.61) and that of PL tunnel was almost perfect (ICC > 0.81). The AM tunnel position was 0.13% deep, 0.58% high and PL tunnel position was 0.01% shallow, 0.13% low compared to quadrant method. The four-point quadrant method was found to have high intra- and inter-observer reliability and accuracy. This method can evaluate the tunnel position regardless of the shape and morphology of the bone tunnel aperture for use of comparison and can provide measurement that can be compared with various reconstruction methods. The four-point quadrant method of this study is considered to have clinical relevance in that it is a detailed and accurate tool for evaluating femoral tunnel position after ACL reconstruction. Case series, Level IV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vishnuvardhan, J.; Muralidharan, Ajith; Balasubramaniam, Krishnan
A full ring STMR array patch had been used for Structural Health Monitoring (SHM) of anisotropic materials where the elastic moduli, correspond to the virgin sample, were used in the calculations. In the present work an in-situ SHM has been successfully demonstrated using a novel compact sensor patch (Double ring single quadrant small footprint STMR array) through simultaneous reconstruction of the elastic moduli, material symmetry, orientation of principal planes and defect imaging. The direct received signals were used to measure Lamb wave velocities, which were used in a slowness based reconstructed algorithm using Genetic Algorithm to reconstruct the elastic moduli,more » material symmetry and orientation of principal planes. The measured signals along with the reconstructed elastic moduli were used in the phased addition algorithm for imaging the damages present on the structure. To show the applicability of the method, simulations were carried out with the double ring single quadrant STMR array configuration to image defects and are compared with the images obtained using simulation data of the full ring STMR array configuration. The experimental validation has been carried out using 3.15 mm quasi-isotropic graphite-epoxy composite. The double ring single quadrant STMR array has advantages over the full ring STMR array as it can carry out in-situ SHM with limited footprint on the structure.« less
Controlled-source seismic interferometry with one way wave fields
NASA Astrophysics Data System (ADS)
van der Neut, J.; Wapenaar, K.; Thorbecke, J. W.
2008-12-01
In Seismic Interferometry we generally cross-correlate registrations at two receiver locations and sum over an array of sources to retrieve a Green's function as if one of the receiver locations hosts a (virtual) source and the other receiver location hosts an actual receiver. One application of this concept is to redatum an area of surface sources to a downhole receiver location, without requiring information about the medium between the sources and receivers, thus providing an effective tool for imaging below complex overburden, which is also known as the Virtual Source method. We demonstrate how elastic wavefield decomposition can be effectively combined with controlled-source Seismic Interferometry to generate virtual sources in a downhole receiver array that radiate only down- or upgoing P- or S-waves with receivers sensing only down- or upgoing P- or S- waves. For this purpose we derive exact Green's matrix representations from a reciprocity theorem for decomposed wavefields. Required is the deployment of multi-component sources at the surface and multi- component receivers in a horizontal borehole. The theory is supported with a synthetic elastic model, where redatumed traces are compared with those of a directly modeled reflection response, generated by placing active sources at the virtual source locations and applying elastic wavefield decomposition on both source and receiver side.
NASA Technical Reports Server (NTRS)
Lampton, M.; Malina, R. F.
1976-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.
Méndez-Sánchez, Roberto; Alburquerque-Sendín, Francisco; Fernández-de-las-Peñas, Cesar; Barbero-Iglesias, Fausto J; Sánchez-Sánchez, Carmen; Calvo-Arenillas, José I; Huijbregts, Peter
2010-06-01
The objective of this study was to assess the immediate effect of a sciatic nerve slider technique added to sustained hamstring stretching on lumbar and lower quadrant flexibility. This was a randomized controlled pilot study. Eight (8) healthy male soccer players (21 +/- 3 years) were randomly assigned to 2 groups. Group A received 5 minutes of bilateral sustained hamstring stretching. Group B additionally received 60 seconds of a sciatic nerve slider technique for each leg. Pre- and postintervention outcomes taken by an assessor blinded to the treatment allocation of the participants included metric distance on finger-to-floor, sit and reach, and the modified Schöber tests and goniometric range of each hip for the straight-leg raise and each knee for seated slump test. Baseline between-group differences were examined with an independent t test and a two-way repeated-measures analysis of variance with p < 0.05 and p < 0.025 analyzed effects of the interventions. There were no significant between-group baseline differences (p > 0.2). There was a significant effect for time on all outcomes (p < 0.01) other than the sit and reach test (p = 0.8). A significant interaction between group . time with greater improvements in group B was found for the modified Schöber test (F = 5.5; p < 0.05), left straight-leg raise (F = 6.1; p < 0.05) and slump test in either leg (left F = 28.7; p = 0.002; right F = 4.9; p < 0.05). Adding a sciatic nerve slider technique to sustained hamstring stretching led to greater immediate increases in both lumbar and lower quadrant flexibility in young healthy soccer players as measured by four of the seven outcomes used. Study limitations and suggestions for future studies are discussed.
Establishing Law and Order After Conflict
2005-01-01
the y-axis indicates the rule of law. This leads to four quadrants . We code the lower-left quadrant as successful, since it includes decreasing...levels of violence and an improving rule of law. The lower-right quadrant is mixed because it includes increasing levels of violence but an improving rule...of law. Cases in the upper-right quadrant are un- successful, since they have increasing levels of violence and a deterio- rating rule of law
NASA Astrophysics Data System (ADS)
Trisutomo, S.
2017-07-01
Importance-Performance Analysis (IPA) has been widely applied in many cases. In this research, IPA was applied to measure perceive on coastal tourism objects and its possibility to be developed as coastal cruise tourism in Makassar. Three objects, i.e. Akkarena recreational site, Losari public space at waterfront, and Paotere traditional Phinisi ships port, were selected and assessed visually from water area by a group of purposive resource persons. The importance and performance of 10 attributes of each site were scored using Likert scale from 1 to 5. Data were processed by SPSS-21 than resulted Cartesian graph which the scores were divided in four quadrants: Quadrant I concentric here, Quadrant II keep up the good work, Quadrant III low priority, and Quadrant IV possible overkill. The attributes in each quadrant could be considered as the platform for preliminary planning of coastal cruise tour in Makassar
Research on detecting spot selection and signal pretreatment of four-quadrant detector
NASA Astrophysics Data System (ADS)
Liu, Wenli; Han, Shaokun
2018-01-01
The four-quadrant detector is a photoelectric position sensor based on the photovoltaic effect. It is widely used in many fields such as target azimuth measurement, end-guided weapon and so on. The selection of the spot and the calculation of the center position are one of the main factors that affect the accuracy of the position measurement of the fourquadrant detector. In order to improve the positioning accuracy of the four-quadrant detector, the method of determining the best spot size is obtained from the theoretical research. The output signal of the four-quadrant detector is a weak narrow pulse signal, which needs to be magnified and widened at high magnitudes. The signal preprocessing method is simulated and experimentally studied. Detecting the spot and the signal processing is realized by the four-quadrant detector, which is important for the use of quadrant detectors for high-precision position measurements.
Medical Approach to Right Colon Diverticulitis with Perforation.
Espinosa, James; Sharma, Rahul; Lucerna, Alan; Stranges, Doug
2017-01-01
We report a case of a 71-year-old female who presented with right lower quadrant (RLQ) abdominal pain and was diagnosed on CT scan with right-sided diverticulitis with perforation. She was admitted under the surgical service after consultation and received intravenous fluids, intravenous antibiotics, and pain medications as needed. The patient was discharged 2 days after admission in stable condition with follow-up with gastroenterology. The differential diagnosis of right lower quadrant abdominal pain is vast. Right-sided diverticulitis often presents in a manner similar to appendicitis. In the absence of peritonitis, conservative treatment may be possible. It is predictable that as the population ages, the incidence of right-sided diverticular disease will increase and will result in more presentations of acute right-sided diverticulitis to the emergency department (ED). The aim of this case report is to increase awareness of the incidence, pathophysiology, presentation, work-up (laboratory studies and imaging), and management (medical and surgical) of right-sided diverticulitis among emergency physicians.
Military Application of Networking by Touch in Collaborative Planning and Tactical Environments
2007-09-01
the network. For example, processing, or understanding, four plus pages per second, let alone 1500 pages, far surpasses a normal user’s ability to...discovering rapid, evolutionary approaches for filtering four to 1500 pages per second into knowledgeable forms relevant to the user. Unless we...weapons at the ready when the TL receives a slight vibration in the upper right quadrant of a vest he is wearing. The familiar tactile sensation
Control Demonstration of a Thin Deformable In-Plane Actuated Mirror
2006-03-01
where a four-quadrant electrode grid sitting behind a pre-shaped membrane mirror uses electrostatic forces to deform the surface. Any manufacturing...to receive the Wavescope data due to its MATLAB and Simulink capa- bilities. The dSPACE computer system is stocked with a UART (Universal Asynchronous...cations,” SPIE Smart Structures and Materials Symposium, EAPAD Conference, Vol. 5051-45 (2003). 6. Bennet, H. E. and others, . “Development of
Multi-modal cockpit interface for improved airport surface operations
NASA Technical Reports Server (NTRS)
Arthur, Jarvis J. (Inventor); Bailey, Randall E. (Inventor); Prinzel, III, Lawrence J. (Inventor); Kramer, Lynda J. (Inventor); Williams, Steven P. (Inventor)
2010-01-01
A system for multi-modal cockpit interface during surface operation of an aircraft comprises a head tracking device, a processing element, and a full-color head worn display. The processing element is configured to receive head position information from the head tracking device, to receive current location information of the aircraft, and to render a virtual airport scene corresponding to the head position information and the current aircraft location. The full-color head worn display is configured to receive the virtual airport scene from the processing element and to display the virtual airport scene. The current location information may be received from one of a global positioning system or an inertial navigation system.
Preceptor Perceptions of Virtual Quality Assurance Experiential Site Visits.
Clarke, Cheryl L; Schott, Kathryn A; Arnold, Austin D
2018-05-01
Objective. To determine preceptor perceptions of the value of experiential quality assurance site visits between virtual and onsite visits, and to gauge preceptor opinions of the optimal method of site visits based on the type of visit received. Methods. Site visits (12 virtual and 17 onsite) were conducted with 29 APPE sites located at least 200 miles from campus. Participating preceptors were invited to complete an online post-visit survey adapted from a previously validated and published survey tool measuring preceptor perceptions of the value of traditional onsite visits. Results. Likert-type score averages for survey questions ranged from 4.2 to 4.6 in the virtual group and from 4.3 to 4.7 in the onsite group. No statistically significant difference was found between the two groups. Preceptors were more inclined to prefer the type of visit they received. Preceptors receiving onsite visits were also more likely to indicate no visit type preference. Conclusion. Preceptors perceived value from both onsite and virtual site visits. Preceptors who experienced virtual site visits highly preferred that methodology. This study suggests that virtual site visits may be a viable alternative for providing experiential quality assurance site visits from a preceptor's perspective.
Florid cemento osseous dysplasia in association with dentigerous cyst.
Sanjai, Karpagaselvi; Kumarswamy, Jayalakshmi; Kumar, Vinod K; Patil, Archana
2010-07-01
We present a case of florid cemento-osseous dysplasia occurring in a 20-year-old Indian woman. The subject presented with three lesions involving the maxillary right quadrant, maxillary left quadrant and mandibular left quadrant. The mandibular left quadrant also demonstrated a cyst.The diagnosis was made by correlating the clinical presentation with that of the radiological and histopathological findings. This is a rare entity because of an unusual combination of Asian race along with the association of dentigerous cyst.
"Perhaps Irrelevant". The Iconography of Tycho Brahe's Small Gilt Brass Quadrant.
Perkins, Emma L; Taub, Liba
2015-01-01
When Tycho Brahe published a description of his astronomical instruments in 1598 as part of a strategy to procure royal patronage, it was not with one of his grander, precision measurement tools that he opened his account, but rather a small brass quadrant with limited observational utility. The defining feature of this instrument was seemingly a small emblematic image inscribed within the arc of the quadrant. Through this symbolic motif Tycho conveyed a moralising message about the relative worth of astronomy. Considering a range of visual productions that may have influenced his iconography, the present paper situates the quadrant within the broader context of Renaissance visual culture and examines the significance of the quadrant in Tycho's wider instrument collection.
Grewal, D S; Brar, G S; Jain, R; Grewal, S P S
2011-01-01
Purpose To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. Methods In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Results Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898–0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm3, ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4–10.0) and 0.11 (95% CI=0.03–0.4), respectively. Conclusions ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles. PMID:21336254
NASA Technical Reports Server (NTRS)
Bonk, Ted (Inventor); Hall, Brendan (Inventor); Smithgall, William Todd (Inventor); Varadarajan, Srivatsan (Inventor); DeLay, Benjamin F. (Inventor)
2017-01-01
Systems and methods for network bandwidth, buffers and timing management using hybrid scheduling of traffic with different priorities and guarantees are provided. In certain embodiments, a method of managing network scheduling and configuration comprises, for each transmitting end station, reserving one exclusive buffer for each virtual link to be transmitted from the transmitting end station; for each receiving end station, reserving exclusive buffers for each virtual link to be received at the receiving end station; and for each switch, reserving a exclusive buffer for each virtual link to be received at an input port of the switch. The method further comprises determining if each respective transmitting end station, receiving end station, and switch has sufficient capability to support the reserved buffers; and reporting buffer infeasibility if each respective transmitting end station, receiving end station, and switch does not have sufficient capability to support the reserved buffers.
Results of endocapsular phacofracture debulking of hard cataracts.
Davison, James A
2015-01-01
To present a phacoemulsification technique for hard cataracts and compare postoperative results using two different ultrasonic tip motions during quadrant removal. A phacoemulsification technique which employs in situ fracture and endocapsular debulking for hard cataracts is presented. The prospective study included 56 consecutive cases of hard cataract (LOCS III NC [Lens Opacification Classification System III, nuclear color], average 4.26), which were operated using the Infiniti machine and the Partial Kelman tip. Longitudinal tip movement was used for sculpting for all cases which were randomized to receive longitudinal or torsional/interjected longitudinal (Intelligent Phaco [IP]) strategies for quadrant removal. Measurements included cumulative dissipated energy (CDE), 3 months postoperative surgically induced astigmatism (SIA), and corneal endothelial cell density (ECD) losses. No complications were recorded in any of the cases. Respective overall and longitudinal vs IP means were as follows: CDE, 51.6±15.6 and 55.7±15.5 vs 48.6±15.1; SIA, 0.36±0.2 D and 0.4±0.2 D vs 0.3±0.2 D; and mean ECD loss, 4.1%±10.8% and 5.9%±13.4% vs 2.7%±7.8%. The differences between longitudinal and IP were not significant for any of the three categories. The endocapsular phacofracture debulking technique is safe and effective for phacoemulsification of hard cataracts using longitudinal or torsional IP strategies for quadrant removal with the Infiniti machine and Partial Kelman tip.
Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M
2014-01-01
We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.
Neuroprotective effects of tetrandrine against vascular dementia
Lv, Yan-ling; Wu, Ze-zhi; Chen, Li-xue; Wu, Bai-xue; Chen, Lian-lian; Qin, Guang-cheng; Gui, Bei; Zhou, Ji-ying
2016-01-01
Tetrandrine is one of the major active ingredients in Menispermaceae Stephania tetrandra S. Moore, and has specific therapeutic effects in ischemic cerebrovascular disease. Its use in vascular dementia has not been studied fully. Here, we investigated whether tetrandrine would improve behavioral and cellular impairments in a two-vessel occlusion rat model of chronic vascular dementia. Eight weeks after model establishment, rats were injected intraperitoneally with 10 or 30 mg/kg tetrandrine every other day for 4 weeks. Behavioral assessment in the Morris water maze showed that model rats had longer escape latencies in training trials, and spent less time swimming in the target quadrant in probe trials, than sham-operated rats. However, rats that had received tetrandrine showed shorter escape latencies and longer target quadrant swimming time than untreated model rats. Hematoxylin-eosin and Nissl staining revealed less neuronal necrosis and pathological damage, and more living cells, in the hippocampus of rats treated with tetrandrine than in untreated model rats. Western blot assay showed that interleukin-1β expression, and phosphorylation of the N-methyl-D-aspartate 2B receptor at tyrosine 1472, were lower in model rats that received tetrandrine than in those that did not. The present findings suggest that tetrandrine may be neuroprotective in chronic vascular dementia by reducing interleukin-1β expression, N-methyl-D-aspartate receptor 2B phosphorylation at tyrosine 1472, and neuronal necrosis. PMID:27127485
Training improves reading speed in peripheral vision: is it due to attention?
Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J
2010-06-01
Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.
The effect of low-level diode laser on COX-2 gene expression in chronic periodontitis patients.
Pesevska, Snezana; Gjorgoski, Icko; Ivanovski, Kiro; Soldatos, Nikolaos K; Angelov, Nikola
2017-09-01
Adjunctive treatments to scaling and root planing (SRP) such as lasers, have been utilized in the treatment of chronic periodontitis, mainly aiming to suppress and eliminate the bacteria, as well as enhancing the healing response. Eighty gingival papilla biopsy samples were obtained from 60 patients diagnosed with chronic advanced periodontitis; randomly assigned to three treatment groups (n = 20), as well as 20 subjects with no periodontal disease [group A]. Group B received SRP on a single quadrant/day for four consecutive days. On day 5, all quadrants were rescaled. Groups C and D received the same treatment as group B plus laser application with the low-level diode laser (630-670 nm, 1.875 J/cm2) for five and ten consecutive days, respectively. Papilla biopsies were obtained from subjects and evaluated by RT-PCR for expression of COX-2. The values in the control group were 0.028 0.014 and baseline values for the examined groups were 0.16 0.18. Significantly decreased level of COX-2 expression for groups C and D was found after treatment, while lowest average expression was found in the group that had the 10 laser treatments supplemental to SRP (0,035 0,014). The results of this study show suppression of COX-2 in gingival tissue after low-level laser treatment as adjunct to SRP.
Diapycnal Advection by Double Diffusion and Turbulence in the Ocean
1999-09-01
quadrant of the map. To evaluate the significance of the finger-regime results, we have implemented a simple statistical test. The dissipation ratio...accepted in nearly all of quadrants I, III and IV of the finger-favorable regime. However, the data in quadrant II (Rp ɚ,Ri> 1) strongly supports the...region of parameter space ( quadrant II, (Rp ɚ,Ri> 1)). 44 1.01 R R R P p p 1.1 1.5 2.5 5 10 30 1001.01 1.1 1.5 2.5 5 10 30
Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S
2015-09-01
The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. There is a significant difference in adherence of microorganisms to the various types of brackets (P < 0.001) and the surfaces (P < 0.05) included in the study. However, there is no significance in the mean adherence of microorganisms in the different quadrants (P > 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (<0.011). The interaction of bracket/surfaces/quadrant was also found to be significant (<0.003). The maximum adherence of microorganisms was observed with the composite bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket surfaces in the four quadrants included in the study.
Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S
2015-01-01
Background: The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. Materials and Methods: At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. Results: There is a significant difference in adherence of microorganisms to the various types of brackets (P < 0.001) and the surfaces (P < 0.05) included in the study. However, there is no significance in the mean adherence of microorganisms in the different quadrants (P > 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (<0.011). The interaction of bracket/surfaces/quadrant was also found to be significant (<0.003). Conclusion: The maximum adherence of microorganisms was observed with the composite bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket surfaces in the four quadrants included in the study. PMID:26435612
Barboni, Piero; Carbonelli, Michele; Savini, Giacomo; Ramos, Carolina do V F; Carta, Arturo; Berezovsky, Adriana; Salomao, Solange R; Carelli, Valerio; Sadun, Alfredo A
2010-03-01
To investigate by optical coherence tomography (OCT) the topographic pattern and temporal sequence of fiber loss in the peripapillary retinal nerve fiber layer (RNFL) of patients with Leber's hereditary optic neuropathy (LHON) in a longitudinal follow-up. Cohort study. Six eyes of 4 patients with molecularly defined LHON were enrolled before the subacute period of visual loss. Subjects were studied by StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA) during a 9-month follow-up starting from the presymptomatic stage of the disease. Examinations were carried out at 4 different time points: presymptomatic stage, time of visual loss, and 3 and 9 months later. Peripapillary RNFL thickness for each quadrant of the optic nerve. Statistical comparisons were performed by ordinary analysis of variance with Dunnett's post-test. A significant increase of RNFL thickness was detected in the temporal and inferior quadrants between the presymptomatic stage and the disease onset (P<0.05). The 360-degree average and the superior and nasal quadrants showed a nonstatistically significant increase of thickness at this time. In the 360-degree average (P<0.01), superior (P<0.01), nasal (P<0.05), and inferior (P<0.01) quadrants, RNFL thickening showed statistically significant changes between the presymptomatic stage and the 3-month follow-up. At 3 months, a nonsignificant reduction of RNFL thickness was detected in the temporal quadrant. A significant reduction of RNFL was detected in all but the nasal quadrants between the presymptomatic stage and the 9-month Follow-up. The RNFL thickness increase first appeared at the temporal and inferior quadrants. Conversely, at 3 months the thickening fibers were more evident in the superior and nasal quadrants. These findings are consistent with the established preferential early involvement of the papillomacular bundle in LHON. We also demonstrated the previously unrecognized simultaneous early involvement of the inferior quadrant. The late involvement of both superior and nasal quadrants suggests a dynamic evolution of the acute stage that continues for 3 months and may represent a therapeutic window of opportunity. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Sakata, Lisandro M; Lavanya, Raghavan; Friedman, David S; Aung, Han T; Gao, Hong; Kumar, Rajesh S; Foster, Paul J; Aung, Tin
2008-05-01
To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA). Cross-sectional observational study. Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore. All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (P<0.001), with fair agreement between the two methods (kappa = 0.40). The frequency of closed angles by AS OCT and gonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT. The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.
Johnson, K A; Skinner, G A; Muir, P
2001-05-01
To quantify geometric, inertial, and histomorphometric properties at the mid-diaphyseal level of left and right metacarpal bones (MCB) of racing Greyhounds. MCB from 7 racing Greyhounds euthanatized for reasons unrelated to MCB abnormalities. Mid-diaphyseal transverse sections of left and right MCB were stained with H&E or microradiographed. Images of stained sections were digitized, and cross-sectional area, cortical area, and maximum and minimum area moments of inertia of each bone were determined. Histomorphometric data (osteonal density, osteonal birefringence, and endosteal new lamellar bone thickness) were collected in 4 quadrants (dorsal, palmar, lateral, medial). Values were compared between limbs and among bones and quadrants. Cross-sectional area, cortical area, and maximum and minimum moments of inertia of left MCB-IV and -V were significantly greater, compared with contralateral bones. Overall osteonal densities in the dorsal quadrants of left MCB were greater, compared with lateral and medial quadrants. Also, percentage of birefringent osteons was significantly greater in the dorsal quadrant of left MCB-III, -IV, and -V, compared with the palmar quadrant. Thickness of new endosteal lamellar bone was not significantly influenced by limb, bone, or quadrant. Increased cortical thickness and geometric properties of left MCB-IV and -V of Greyhounds, together with altered turnover and orientation of osteons in the dorsal quadrants of left MCB, are site-specific adaptive responses associated with asymmetric cyclic loading as a result of racing on circular tracks. Site-specific adaptive remodeling may be important in the etiopathogenesis of fatigue fractures in racing Greyhounds.
Specific Location of Disc Hemorrhage is Linked to Nerve Fiber Layer Defects.
Yoo, Young Cheol; Kim, Joon Mo; Park, Han Seok; Yoo, Chungkwon; Shim, Seong Hee; Won, Yu Sam; Park, Ki Ho; Chang, Robert T
2017-06-01
To investigate the relationship between retinal nerve fiber layer (RNFL) defects and the quadrant and proximal location of disc hemorrhages (DHs) in a large population examined for health screening. A total of 168,044 subjects older than 20 years underwent a single screening ophthalmic examination with color fundus photography as part of a comprehensive health screening program. The presence and location of DHs and RNFL defects were assessed. The DH locations were defined according to the quadrant location (inferotemporal, superotemporal, inferonasal, or superonasal) and the most proximal end of DHs relative to the disc center (cup base, cup margin, disc rim, or extrapapillary region). Using these two location descriptors as independent variables, a logistic regression analysis was conducted to explore the effects of DH location on RNFL defects. Two hundred twenty-six eyes had DH and 120 (53.1%) of them had RNFL defects. After adjusting for proximal location, DHs located in the inferotemporal quadrant accompanied RFNL defects 12 times more frequently than those in the superonasal quadrant (odds ratio [OR], 11.81; P = .004). Conversely, after adjusting for quadrant location, the ORs for an associated RNFL defect were 3.73 (P < .001), 16.54 (P < .001), and 8.91 (P = .002) for DHs with the proximal end at the disc rim, cup margin, and cup base, respectively. Among the four quadrants and four proximal locations, DHs were identified most frequently in the inferotemporal quadrant and outside the disc, respectively. Some DH locations, such as the inferotemporal quadrant and the cup margin, were associated with RNFL defects, whereas others were not.
An Integral Approach to Counseling Ethics
ERIC Educational Resources Information Center
Foster, Durwin; Black, Timothy G.
2007-01-01
The authors offer an integral approach to counseling ethics using K. Wilber's (2000a, 2000b) integral metatheory. The article examines traditional counseling ethics through the lens of K. Wilber's (2000a, 2000b) "all-quadrants, all-levels" model, consisting of quadrants, levels, lines, states, and types. The authors begin with the 4 quadrants and…
Quadrant Analysis as a Strategic Planning Technique in Curriculum Development and Program Marketing.
ERIC Educational Resources Information Center
Lynch, James; And Others
1996-01-01
Quadrant analysis, a widely-used research technique, is suggested as useful in college or university strategic planning. The technique uses consumer preference data and produces information suitable for a wide variety of curriculum and marketing decisions. Basic quadrant analysis design is described, and advanced variations are discussed, with…
Honors for the Virtual Frog Dissection Kit
Honors for the Virtual Frog Dissection Kit Study Web The dissection kit received a StudyWeb award Frog Project | Virtual Frog Page last modified: 01/23/05 Contacts: Bill Johnston, David Robertson
MARK’s Quadrant scoring system: a symptom-based targeted screening tool for gastric cancer
Tata, Mahadevan D.; Gurunathan, Ramesh; Palayan, Kandasami
2014-01-01
Background Gastric cancer is notably one of the leading causes of cancer-related death in the world. In Malaysia, these patients present in the advanced stage, thus narrowing the treatment options and making the surgery nearly impossible for successful curative resection. Failure to identify high-risk patients and delay in diagnostic endoscope procedure contributed to the delay in diagnosis. The aim of the study was to develop and validate a scoring system (MARK’s Quadrant) which can identify symptomatic patients who are at risk for gastric cancer. Methods A 3-phase approach was undertaken: Phase 1: development of the weighted scoring system; Phase 2: estimating positive predicting value of MARK’s Quadrant; and Phase 3: a) testing the validity of MARK’s Quadrant in an open-access endoscope system; and b) comparing its usefulness compared to conventional referral system. Results In phases 1 and 2, MARK’s Quadrant with weighted symptoms was developed. The sensitivity of MARK’s Quadrant is 88% and the specificity is 45.5% to detect cancerous and precancerous lesions of gastric. This was confirmed by the prospective data from phase 3 of this study where the diagnostic yield of MARK’s Quadrant to detect any pathological lesion was 95.2%. This score has a high accuracy efficiency of 75%, hence comparing to routine referral system it has an odds ratio (95%CI) of 10.98 (4.63-26.00), 6.71 (4.46-10.09) and 0.95 (0.06-0.15) (P<0.001 respectively) for cancer, precancerous lesion and benign lesion diagnosis respectively. Conclusion MARK’s Quadrant is a useful tool to detect early gastric cancer among symptomatic patients in a low incidence region. PMID:24714557
Patient Satisfaction with Virtual Obstetric Care.
Pflugeisen, Bethann Mangel; Mou, Jin
2017-07-01
Introduction The importance of patient satisfaction in US healthcare is increasing, in tandem with the advent of new patient care modalities, including virtual care. The purpose of this study was to compare the satisfaction of obstetric patients who received one-third of their antenatal visits in videoconference ("Virtual-care") compared to those who received 12-14 face-to-face visits in-clinic with their physician/midwife ("Traditional-care"). Methods We developed a four-domain satisfaction questionnaire; Virtual-care patients were asked additional questions about technology. Using a modified Dillman method, satisfaction surveys were sent to Virtual-care (N = 378) and Traditional-care (N = 795) patients who received obstetric services at our institution between January 2013 and June 2015. Chi-squared tests of association, t-tests, logistic regression, and ANOVA models were used to evaluate differences in satisfaction and self-reported demographics between respondents. Results Overall satisfaction was significantly higher in the Virtual-care cohort (4.76 ± 0.44 vs. 4.47 ± 0.59; p < .001). Parity ≥ 1 was the sole significant demographic variable impacting Virtual-care selection (OR = 2.4, 95% CI: 1.5-3.8; p < .001). Satisfaction of Virtual-care respondents was not significantly impacted by the incorporation of videoconferencing, Doppler, and blood pressure monitoring technology into their care. The questionnaire demonstrated high internal consistency as measured by domain-based correlations and Cronbach's alpha. Discussion Respondents from both models were highly satisfied with care, but those who had selected the Virtual-care model reported significantly higher mean satisfaction scores. The Virtual-care model was selected by significantly more women who already have children than those experiencing pregnancy for the first time. This model of care may be a reasonable alternative to traditional care.
NASA Technical Reports Server (NTRS)
Steele, Glen; Lansdowne, Chatwin; Zucha, Joan; Schlensinger, Adam
2013-01-01
The Soft Decision Analyzer (SDA) is an instrument that combines hardware, firmware, and software to perform realtime closed-loop end-to-end statistical analysis of single- or dual- channel serial digital RF communications systems operating in very low signal-to-noise conditions. As an innovation, the unique SDA capabilities allow it to perform analysis of situations where the receiving communication system slips bits due to low signal-to-noise conditions or experiences constellation rotations resulting in channel polarity in versions or channel assignment swaps. SDA s closed-loop detection allows it to instrument a live system and correlate observations with frame, codeword, and packet losses, as well as Quality of Service (QoS) and Quality of Experience (QoE) events. The SDA s abilities are not confined to performing analysis in low signal-to-noise conditions. Its analysis provides in-depth insight of a communication system s receiver performance in a variety of operating conditions. The SDA incorporates two techniques for identifying slips. The first is an examination of content of the received data stream s relation to the transmitted data content and the second is a direct examination of the receiver s recovered clock signals relative to a reference. Both techniques provide benefits in different ways and allow the communication engineer evaluating test results increased confidence and understanding of receiver performance. Direct examination of data contents is performed by two different data techniques, power correlation or a modified Massey correlation, and can be applied to soft decision data widths 1 to 12 bits wide over a correlation depth ranging from 16 to 512 samples. The SDA detects receiver bit slips within a 4 bits window and can handle systems with up to four quadrants (QPSK, SQPSK, and BPSK systems). The SDA continuously monitors correlation results to characterize slips and quadrant change and is capable of performing analysis even when the receiver under test is subjected to conditions where its performance degrades to high error rates (30 percent or beyond). The design incorporates a number of features, such as watchdog triggers that permit the SDA system to recover from large receiver upsets automatically and continue accumulating performance analysis unaided by operator intervention. This accommodates tests that can last in the order of days in order to gain statistical confidence in results and is also useful for capturing snapshots of rare events.
Niraj, G; Kelkar, A; Hart, E; Horst, C; Malik, D; Yeow, C; Singh, B; Chaudhri, S
2014-04-01
Posterior transversus abdominis plane blocks have been reported to be an effective method of providing analgesia after lower abdominal surgery. We compared the efficacy of a novel technique of providing continuous transversus abdominis plane analgesia with epidural analgesia in patients on an enhanced recovery programme following laparoscopic colorectal surgery. A non-inferiority comparison was used. Adult patients undergoing elective laparoscopic colorectal surgery were randomly assigned to receive continuous transversus abdominis plane analgesia (n = 35) vs epidural analgesia (n = 35), in addition to a postoperative analgesic regimen comprising regular paracetamol, regular diclofenac and tramadol as required. Sixty-one patients completed the study. The transversus group received four-quadrant transversus abdominis plane blocks and bilateral posterior transversus abdominis plane catheters that were infused with levobupivacaine 0.25% for 48 h. The epidural group received an infusion of bupivacaine and fentanyl. The primary outcome measure was visual analogue scale pain score on coughing at 24 h after surgery. We found no significant difference in median (IQR [range]) visual analogue scores during coughing at 24 h between the transversus group 2.5 (1.0-3.0 [0-5.5]) and the epidural group 2.5 (1.0-5.0 [0-6.0]). The one-sided 97.5% CI was a 0.0 (∞-1.0) difference in means, establishing non-inferiority. There were no significant differences between the groups for tramadol consumption. Success rate was 28/30 (93%) in the transversus group vs 27/31 (87%) in the epidural group. Continuous transversus abdominis plane infusion was non-inferior to epidural infusion in providing analgesia after laparoscopic colorectal surgery. © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Results of endocapsular phacofracture debulking of hard cataracts
Davison, James A
2015-01-01
Purpose/aim of the study To present a phacoemulsification technique for hard cataracts and compare postoperative results using two different ultrasonic tip motions during quadrant removal. Materials and methods A phacoemulsification technique which employs in situ fracture and endocapsular debulking for hard cataracts is presented. The prospective study included 56 consecutive cases of hard cataract (LOCS III NC [Lens Opacification Classification System III, nuclear color], average 4.26), which were operated using the Infiniti machine and the Partial Kelman tip. Longitudinal tip movement was used for sculpting for all cases which were randomized to receive longitudinal or torsional/interjected longitudinal (Intelligent Phaco [IP]) strategies for quadrant removal. Measurements included cumulative dissipated energy (CDE), 3 months postoperative surgically induced astigmatism (SIA), and corneal endothelial cell density (ECD) losses. Results No complications were recorded in any of the cases. Respective overall and longitudinal vs IP means were as follows: CDE, 51.6±15.6 and 55.7±15.5 vs 48.6±15.1; SIA, 0.36±0.2 D and 0.4±0.2 D vs 0.3±0.2 D; and mean ECD loss, 4.1%±10.8% and 5.9%±13.4% vs 2.7%±7.8%. The differences between longitudinal and IP were not significant for any of the three categories. Conclusion The endocapsular phacofracture debulking technique is safe and effective for phacoemulsification of hard cataracts using longitudinal or torsional IP strategies for quadrant removal with the Infiniti machine and Partial Kelman tip. PMID:26203213
Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John
2015-11-01
Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.
Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin.
Colquhoun, Douglas A; Forkin, Katherine T; Durieux, Marcel E; Thiele, Robert H
2012-04-01
The decision to administer blood products is complex and multifactorial. Accurate assessment of the concentration of hemoglobin [Hgb] is a key component of this evaluation. Recently a noninvasive method of continuously measuring hemoglobin (SpHb) has become available with multi-wavelength Pulse CO-Oximetry. The accuracy of this device is well documented, but the trending ability of this monitor has not been previously described. Twenty patients undergoing major thoracic and lumbar spine surgery were recruited. All patients received radial arterial lines. On the contralateral index finger, a R1 25 sensor (Rev E) was applied and connected to a Radical-7 Pulse CO-Oximeter (both Masimo Corp, Irvine, CA). Blood samples were drawn intermittently at the anesthesia provider's discretion and were analyzed by the operating room satellite laboratory CO-Oximeter. The value of Hgb and SpHb at that time point was compared. Trend analysis was performed by the four quadrant plot technique, testing directionality of change, and Critchley's polar plot method testing both directionality and magnitude of the change in values. Eighty-eight samples recorded at times of sufficient signal quality were available for analysis. Four quadrant plot analysis revealed 94% of data within the quadrants associated with the correct direction change, and 90% of data points lay within the analysis bounds proposed by Critchley. Pulse CO-Oximetry offers an acceptable trend monitor in patients undergoing major spine surgery. Future work should explore the ability of this device to detect large changes in hemoglobin, as well as its applicability in additional surgical and non-surgical patient populations.
NASA Astrophysics Data System (ADS)
Sakarya, Doǧan Uǧur
2017-10-01
Beam steering optical arrangement needs less volume envelope for same field of regard than other gimbal approaches. Both for imaging and four quadrant missile applications, volume is critical parameter limiting system performance. Therefore, a conceptual design of beam steering method has been focused on both imaging and four quadrant missiles. In this study; four different optical designs have been made by using both beam steering and regular method for mid-wave infra-red imaging and four quadrant systems. Optical designs performances have been illustrated in simulation results. By using manufactured Risley prisms, some experimental results are conducted to compare simulations results.
Stein, Steffen; Schauseil, Michael; Hellak, Andreas; Korbmacher-Steiner, Heike; Braun, Andreas
2018-05-18
The objective of this split-mouth trial was to investigate the influence of photobiomodulation therapy (PBMT) on adjuvant treatment of gingivitis induced by multi-bracket appliances, after bracket debonding and professional tooth cleaning. Thirteen patients (mean age 16.15 years; standard deviation ±2.12 years) who had completed active orthodontic treatment with fixed orthodontic appliances in an orthodontic clinic were included on a randomized basis. At time point T0, after bracket debonding and professional tooth cleaning, the papilla bleeding index (PBI) and bleeding on probing (BOP) were assessed in the upper jaw by the blinded investigator (M.S.), who was not aware at any time of which quadrant received PBMT. The study was based on a patient-blinded split-mouth design. In each patient, PBMT was administered by a practitioner (S.S.) in one upper quadrant (wavelength: 660 nm; Power: 100 mW; Power density: 100 mW/cm 2 ; Energy density per application point = 2 J/cm 2 ; Energy per application point = 2 J; Total dose = 52 J/cm 2 ; Total energy = 52 J; Irradiation time: 26 × 20 sec), while the other upper quadrant received a simulated laser application with the laser system turned off. Randomized equal allocation of the sides was accomplished. The second PBI and BOP assessment followed 4-6 days after laser irradiation (T1) by M.S. No statistical differences were observed between the sides with regard to PBI and BOP values at T0 (p > 0.05). The PBI and BOP values decreased significantly between T0 and T1 on both sides (p < 0.05). At T1, the PBI and BOP values were significantly lower in the laser side in comparison with the control side (p < 0.05). On the basis of these results and study parameters, adjuvant PBMT is able to accelerate the healing process in patients with gingivitis induced by multi-bracket appliances.
CapDEM TD - Modeling and Simulation (Role and Tools) State of the Art Report
2005-01-01
office/wcm1/ornclinfn/ciefilnlt rnsnx [55] http://www.idefine.com/Tutorial/TutOiial%20Sales%20Page.htm [56] Gartner , " Magic Quadrant for Business ...21 Figure 3-5: Gartner Magic Quadrant For BPA, 2004 (56...of January 2004 Niche Players Visionaries ------- Completeness of Vision ..., Figure 3-5: Gartner Magic Quadrant For BPA, 2004 [56] Gartner , Inc
ERIC Educational Resources Information Center
Crane, Laura; Benachour, Phillip
2013-01-01
The paper describes the analysis of user location and time stamp information automatically logged when students receive and interact with electronic updates from the University's virtual learning environment. The electronic updates are sent to students' mobile devices using RSS feeds. The mobile reception of such information can be received in…
A survey on the utilization of disposable quadrant articulators.
Thornton, Linda J
2002-01-01
This study evaluated utilization of the six most popular disposable quadrant articulators presently used in crown fabrication. Most general practitioners and crown and bridge laboratory technicians reported that they frequently or always used disposable quadrant articulators for single units and simple three-unit fixed partial dentures. All evaluated articulators demonstrated an inability to maintain and repeat the centric stop position. The disposable quadrant articulator, used in combination with dual-arch impressions, is a viable method for fabricating single and short-span restorations. While a nonrepeatable centric stop was present in all six articulators evaluated, the method was considered a time-efficient and cost-saving alternative to traditional all-metal simple-hinge articulators.
Quadrant CFD Analysis of a Mixer-Ejector Nozzle for HSCT Applications
NASA Technical Reports Server (NTRS)
Yoder, Dennis A.; Georgiadis, Nicholas J.; Wolter, John D.
2005-01-01
This study investigates the sidewall effect on flow within the mixing duct downstream of a lobed mixer-ejector nozzle. Simulations which model only one half-chute width of the ejector array are compared with those which model one complete quadrant of the nozzle geometry and with available experimental data. These solutions demonstrate the applicability of the half-chute technique to model the flowfield far away from the sidewall and the necessity of a full-quadrant simulation to predict the formation of a low-energy flow region near the sidewall. The quadrant solutions are further examined to determine the cause of this low-energy region, which reduces the amount of mixing and lowers the thrust of the nozzle. Grid resolution and different grid topologies are also examined. Finally, an assessment of the half-chute and quadrant approaches is made to determine the ability of these simulations to provide qualitative and/or quantitative predictions for this type of complex flowfield.
The phonatory deviation diagram: a novel objective measurement of vocal function.
Madazio, Glaucya; Leão, Sylvia; Behlau, Mara
2011-01-01
To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.
Furdea, Adrian; Preissl, Hubert; Lowery, Curtis L; Eswaran, Hari; Govindan, Rathinaswamy B
2011-01-01
We propose a novel approach to calculate the conduction velocity (CV) of the uterine contraction bursts in magnetomyogram (MMG) signals measured using a multichannel SQUID array. For this purpose, we partition the sensor coordinates into four different quadrants and identify the contractile bursts using a previously proposed Hilbert-wavelet transform approach. If contractile burst is identified in more than one quadrant, we calculate the center of gravity (CoG) in each quadrant for each time point as the sum of the product of the sensor coordinates with the Hilbert amplitude of the MMG signals normalized by the sum of the Hilbert amplitude of the signals over all sensors. Following this we compute the delay between the CoGs of all (six) possible quadrant pairs combinations. As a first step, we validate this approach by simulating a stochastic model based on independent second-order autoregressive processes (AR2) and we divide them into 30 second disjoint windows and insert burst activity at specific time instances in preselected sensors. Also we introduce a lag of 5 ± 1 seconds between different quadrants. Using our approach we calculate the CoG of the signals in a quadrant. To this end, we compute the delay between CoGs obtained from different quadrants and show that our approach is able to reliably capture the delay incorporated in the model. We apply the proposed approach to 19 serial MMG data obtained from two subjects and show an increase in the CV as the subjects approached labor.
Weir, Erica; d'Entremont, Nadine; Stalker, Shelley; Kurji, Karim; Robinson, Victoria
2009-01-01
Background All aspects of the heath care sector are being asked to account for their performance. This poses unique challenges for local public health units with their traditional focus on population health and their emphasis on disease prevention, health promotion and protection. Reliance on measures of health status provides an imprecise and partial picture of the performance of a health unit. In 2004 the provincial Institute for Clinical Evaluative Sciences based in Ontario, Canada introduced a public-health specific balanced scorecard framework. We present the conceptual deliberations and decisions undertaken by a health unit while adopting the framework. Discussion Posing, pondering and answering key questions assisted in applying the framework and developing indicators. Questions such as: Who should be involved in developing performance indicators? What level of performance should be measured? Who is the primary intended audience? Where and how do we begin? What types of indicators should populate the health status and determinants quadrant? What types of indicators should populate the resources and services quadrant? What type of indicators should populate the community engagement quadrant? What types of indicators should populate the integration and responsiveness quadrants? Should we try to link the quadrants? What comparators do we use? How do we move from a baseline report card to a continuous quality improvement management tool? Summary An inclusive, participatory process was chosen for defining and creating indicators to populate the four quadrants. Examples of indicators that populate the four quadrants of the scorecard are presented and key decisions are highlighted that facilitated the process. PMID:19426508
Weir, Erica; d'Entremont, Nadine; Stalker, Shelley; Kurji, Karim; Robinson, Victoria
2009-05-08
All aspects of the heath care sector are being asked to account for their performance. This poses unique challenges for local public health units with their traditional focus on population health and their emphasis on disease prevention, health promotion and protection. Reliance on measures of health status provides an imprecise and partial picture of the performance of a health unit. In 2004 the provincial Institute for Clinical Evaluative Sciences based in Ontario, Canada introduced a public-health specific balanced scorecard framework. We present the conceptual deliberations and decisions undertaken by a health unit while adopting the framework. Posing, pondering and answering key questions assisted in applying the framework and developing indicators. Questions such as: Who should be involved in developing performance indicators? What level of performance should be measured? Who is the primary intended audience? Where and how do we begin? What types of indicators should populate the health status and determinants quadrant? What types of indicators should populate the resources and services quadrant? What type of indicators should populate the community engagement quadrant? What types of indicators should populate the integration and responsiveness quadrants? Should we try to link the quadrants? What comparators do we use? How do we move from a baseline report card to a continuous quality improvement management tool? An inclusive, participatory process was chosen for defining and creating indicators to populate the four quadrants. Examples of indicators that populate the four quadrants of the scorecard are presented and key decisions are highlighted that facilitated the process.
Examining the Angular Resolution of the Astro-H's Soft X-Ray Telescopes
NASA Technical Reports Server (NTRS)
Sato, Toshiki; Iizuka, Ryo; Ishida, Manabu; Kikuchi, Naomichi; Maeda, Yoshitomo; Kurashima, Sho; Nakaniwa, Nozomi; Tomikawa, Kazuki; Hayashi, Takayuki; Mori, Hideyuki;
2016-01-01
The international x-ray observatory ASTRO-H was renamed Hitomi after launch. It covers a wide energy range from a few hundred eV to 600 keV. It is equipped with two soft x-ray telescopes (SXTs: SXT-I and SXT-S) for imaging the soft x-ray sky up to 12 keV, which focus an image onto the respective focal-plane detectors: CCD camera (SXI) and a calorimeter (SXS). The SXTs are fabricated in a quadrant unit. The angular resolution in half-power diameter (HPD) of each quadrant of the SXTs ranges between 1.1 and 1.4 arc min at 4.51 keV. It was also found that one quadrant has an energy dependence on the HPD. We examine the angular resolution with spot scan measurements. In order to understand the cause of imaging capability deterioration and to reflect it to the future telescope development, we carried out spot scan measurements, in which we illuminate all over the aperture of each quadrant with a square beam 8 mm on a side. Based on the scan results, we made maps of image blurring and a focus position. The former and the latter reflect figure error and positioning error, respectively, of the foils that are within the incident 8 mm x 8 mm beam. As a result, we estimated those errors in a quadrant to be approx. 0.9 to 1.0 and approx. 0.6 to 0.9 arc min, respectively. We found that the larger the positioning error in a quadrant is, the larger its HPD is. The HPD map, which manifests the local image blurring, is very similar from quadrant to quadrant, but the map of the focus position is different from location to location in each telescope. It is also found that the difference in local performance causes energy dependence of the HPD.
Microphysical Structures of Hurricane Irma Observed by Polarimetric Radar
NASA Astrophysics Data System (ADS)
Didlake, A. C.; Kumjian, M. R.
2017-12-01
This study examines dual-polarization radar observations of Hurricane Irma as its center passed near the WSR-88D radar in Puerto Rico, capturing needed microphysical information of a mature tropical cyclone. Twenty hours of observations continuously sampled the inner core precipitation features. These data were analyzed by annuli and azimuth, providing a bulk characterization of the primary eyewall, secondary eyewall, and rainbands as they varied around the storm. Polarimetric radar variables displayed distinct signatures of convective and stratiform precipitation in the primary eyewall and rainbands that were organized in a manner consistent with the expected kinematic asymmetry of a storm in weak environmental wind shear but with moderate low-level storm-relative flow. In the front quadrants of the primary eyewall, vertical profiles of differential reflectivity (ZDR) exhibit increasing values with decreasing height consistent with convective precipitation processes. In particular, the front-right quadrant exhibits a signature in reflectivity (ZH) and ZDR indicating larger, sparser drops, which is consistent with a stronger updraft present in this quadrant. In the rear quadrants, a sharply peaked ZDR maximum occurs within the melting layer, which is attributed of stratiform processes. In the rainbands, the convective to stratiform transition can be seen traveling from the front-right to the front-left quadrant. The front-right quadrant exhibits lower co-polar correlation coefficient (ρHV) values in the 3-8 km altitude layer, suggesting larger vertical spreading of various hydrometeors that occurs in convective vertical motions. The front-left quadrant exhibits larger ρHV values, suggesting less diversity of hydrometeor shapes, consistent with stratiform processes. The secondary eyewall did not exhibit a clear signature of processes preferred in a specific quadrant, and a temporal analysis of the secondary eyewall revealed a complex evolution of its structure. These results provide important microphysical insight that are critical for understanding the inner core processes modulating tropical cyclone intensity and structure.
Stainer, Matthew J.; Scott-Brown, Kenneth C.; Tatler, Benjamin W.
2013-01-01
Where people look when viewing a scene has been a much explored avenue of vision research (e.g., see Tatler, 2009). Current understanding of eye guidance suggests that a combination of high and low-level factors influence fixation selection (e.g., Torralba et al., 2006), but that there are also strong biases toward the center of an image (Tatler, 2007). However, situations where we view multiplexed scenes are becoming increasingly common, and it is unclear how visual inspection might be arranged when content lacks normal semantic or spatial structure. Here we use the central bias to examine how gaze behavior is organized in scenes that are presented in their normal format, or disrupted by scrambling the quadrants and separating them by space. In Experiment 1, scrambling scenes had the strongest influence on gaze allocation. Observers were highly biased by the quadrant center, although physical space did not enhance this bias. However, the center of the display still contributed to fixation selection above chance, and was most influential early in scene viewing. When the top left quadrant was held constant across all conditions in Experiment 2, fixation behavior was significantly influenced by the overall arrangement of the display, with fixations being biased toward the quadrant center when the other three quadrants were scrambled (despite the visual information in this quadrant being identical in all conditions). When scenes are scrambled into four quadrants and semantic contiguity is disrupted, observers no longer appear to view the content as a single scene (despite it consisting of the same visual information overall), but rather anchor visual inspection around the four separate “sub-scenes.” Moreover, the frame of reference that observers use when viewing the multiplex seems to change across viewing time: from an early bias toward the display center to a later bias toward quadrant centers. PMID:24069008
Multi-Quadrant Biopsy Technique Improves Diagnostic Ability in Large Heterogeneous Renal Masses.
Abel, E Jason; Heckman, Jennifer E; Hinshaw, Louis; Best, Sara; Lubner, Meghan; Jarrard, David F; Downs, Tracy M; Nakada, Stephen Y; Lee, Fred T; Huang, Wei; Ziemlewicz, Timothy
2015-10-01
Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10 cm (IQR 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (p=0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs 2 of 8 (25.0%) (p=0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Determination of retinal surface area.
Nagra, Manbir; Gilmartin, Bernard; Thai, Ngoc Jade; Logan, Nicola S
2017-09-01
Previous attempts at determining retinal surface area and surface area of the whole eye have been based upon mathematical calculations derived from retinal photographs, schematic eyes and retinal biopsies of donor eyes. 3-dimensional (3-D) ocular magnetic resonance imaging (MRI) allows a more direct measurement, it can be used to image the eye in vivo, and there is no risk of tissue shrinkage. The primary purpose of this study is to compare, using T2-weighted 3D MRI, retinal surface areas for superior-temporal (ST), inferior-temporal (IT), superior-nasal (SN) and inferior-nasal (IN) retinal quadrants. An ancillary aim is to examine whether inter-quadrant variations in area are concordant with reported inter-quadrant patterns of susceptibility to retinal breaks associated with posterior vitreous detachment (PVD). Seventy-three adult participants presenting without retinal pathology (mean age 26.25 ± 6.06 years) were scanned using a Siemens 3-Tesla MRI scanner to provide T2-weighted MR images that demarcate fluid-filled internal structures for the whole eye and provide high-contrast delineation of the vitreous-retina interface. Integrated MRI software generated total internal ocular surface area (TSA). The second nodal point was used to demarcate the origin of the peripheral retina in order to calculate total retinal surface area (RSA) and quadrant retinal surface areas (QRSA) for ST, IT, SN, and IN quadrants. Mean spherical error (MSE) was -2.50 ± 4.03D and mean axial length (AL) 24.51 ± 1.57 mm. Mean TSA and RSA for the RE were 2058 ± 189 and 1363 ± 160 mm 2 , respectively. Repeated measures anova for QRSA data indicated a significant difference within-quadrants (P < 0.01) which, contrasted with ST (365 ± 43 mm 2 ), was significant for IT (340 ± 40 mm 2 P < 0.01), SN (337 ± 40 mm 2 P < 0.01) and IN (321 ± 39 mm 2 P < 0.01) quadrants. For all quadrants, QRSA was significantly correlated with AL (P < 0.01) and exhibited equivalent increases in retinal area/mm increase in AL. Although the differences between QRSAs are relatively small, there was evidence of concordance with reported inter-quadrant patterns of susceptibility to retinal breaks associated with PVD. The data allow AL to be converted to QRSAs, which will assist further work on inter-quadrant structural variation. © 2017 Anatomical Society.
Virtual Learning Environments.
ERIC Educational Resources Information Center
Follows, Scott B.
1999-01-01
Illustrates the possibilities and educational benefits of virtual learning environments (VLEs), based on experiences with "Thirst for Knowledge," a VLE that simulates the workplace of a major company. While working in this virtual office world, students walk through the building, attend meetings, read reports, receive e-mail, answer the telephone,…
1975-04-17
1-3. CO2 laser raster scan sensitivity profile of HgCdTe quadrantal array with two of the four elements connected to 50-ohm load. Fig. 1-4...Response of HgCdTe quadrantal array to CO2 laser beam scanned across center with (a) two opposite photodiodes connected, and (b) all four photodiodes...RESEARCH 1 A. Planar HgCdTe Quadrantal Arrays for Gigahertz Heterodyne Operation at 10.6 (im 1 B. Electrical Properties of Silicon Ion-Implanted
Research on correction algorithm of laser positioning system based on four quadrant detector
NASA Astrophysics Data System (ADS)
Gao, Qingsong; Meng, Xiangyong; Qian, Weixian; Cai, Guixia
2018-02-01
This paper first introduces the basic principle of the four quadrant detector, and a set of laser positioning experiment system is built based on the four quadrant detector. Four quadrant laser positioning system in the actual application, not only exist interference of background light and detector dark current noise, and the influence of random noise, system stability, spot equivalent error can't be ignored, so it is very important to system calibration and correction. This paper analyzes the various factors of system positioning error, and then propose an algorithm for correcting the system error, the results of simulation and experiment show that the modified algorithm can improve the effect of system error on positioning and improve the positioning accuracy.
Becher, T; Bußmeyer, M; Lautenschläger, I; Schädler, D; Weiler, N; Frerichs, I
2018-06-01
Electrical impedance tomography (EIT) is increasingly used for continuous monitoring of ventilation in intensive care patients. Clinical observations in patients with pleural effusion show an increase in out-of-phase impedance changes. We hypothesised that out-of-phase impedance changes are a typical EIT finding in patients with pleural effusion and could be useful in its detection. We conducted a prospective observational study in intensive care unit patients with and without pleural effusion. In patients with pleural effusion, EIT data were recorded before, during, and after unilateral drainage of pleural effusion. In patients with no pleural effusion, EIT data were recorded without any intervention. EIT images were separated into four quadrants of equal size. We analysed the sum of out-of-phase impedance changes in the affected quadrant in patients with pleural effusion before, during, and after drainage and compared it with the sum of out-of-phase impedance changes in the dorsal quadrants of patients without pleural effusion. We included 20 patients with pleural effusion and 10 patients without pleural effusion. The median sum of out-of-phase impedance changes was 70 (interquartile range 49-119) arbitrary units (a.u.) in patients with pleural effusion before drainage, 25 (12-46) a.u. after drainage (P<0.0001) and 11 (6-17) a.u. in patients without pleural effusion (P<0.0001 vs pleural effusion before drainage). The area under the receiver operating characteristics curve was 0.96 (95% limits of agreement 0.91-1.01) between patients with pleural effusion before drainage and those without pleural effusion. In patients monitored with EIT, the presence of out-of-phase impedance changes is highly suspicious of pleural effusion and should trigger further examination. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook
2017-11-01
To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.
Şahin, Muhammed; Şahin, Alparslan; Kılınç, Faruk; Yüksel, Harun; Özkurt, Zeynep Gürsel; Türkcü, Fatih Mehmet; Pekkolay, Zafer; Soylu, Hikmet; Çaça, İhsan
2017-06-01
Increased secretion of growth hormone and insulin-like growth factor-1 in acromegaly has various effects on multiple organs. However, the ocular effects of acromegaly have yet to be investigated in detail. The aim of the present study was to compare retina ganglion cell/inner plexiform layer (GCIPL) and peripapillary nerve fiber layer thickness (pRNFL) between patients with acromegaly and healthy control subjects using spectral domain optical coherence tomography (SD-OCT). This cross-sectional, comparative study included 18 patients with acromegaly and 20 control subjects. All participants underwent SD-OCT to measure pRNFL (in the seven peripapillary areas), GCIPL (in the nine ETDRS areas), and central macular thickness (CMT). Visual field (VF) examinations were performed using a Humphrey field analyzer in acromegalic patients. Measurements were compared between patients with acromegaly and control subjects. A total of 33 eyes of 18 patients with acromegaly and 40 eyes of 20 control subjects met the inclusion criteria of the present study. The overall calculated average pRNFL thickness was significantly lower in patients with acromegaly than in control subjects (P = 0.01), with pRNFL thickness significantly lower in the temporal superior and temporal inferior quadrants. Contrary to our expectations, pRNFL thickness in the nasal quadrant was similar between acromegalic and control subjects. The mean overall pRNFL thickness and superonasal, nasal, inferonasal, and inferotemporal quadrant pRNFL thicknesses were found to correlate with the mean deviation (MD) according to Spearman's correlation. However, other quadrants were not correlated with VF sensitivity. No significant difference in CMT values was observed (P = 0.6). GCIPL thickness was significantly lower in all quadrants of the inner and outer macula, except for central and inferior outer quadrants, in the acromegaly group than that in the control group (P < 0.05). GCIPL thicknesses of the inferior inner and outer macula quadrants were found to correlate with MD, whereas no correlation was observed between other quadrants and VF sensitivity. We demonstrated that GCIPL thickness decreased in patients with acromegaly compared with that in control subjects. However, the nasal quadrant pRNFL thickness was similar in acromegaly, in contrast to our expectations. SD-OCT may have utility in the assessment of the effects of acromegaly on retinal structures.
Gao, Y Y; Chen, X H
2017-06-05
Objective: The aim of this study is to investigate the clinical significance of four quadrant localization in the diagnosis and treatment of unknown primary cervical metastases. Method: The clinical data with unknown primary cervical metastases, were analyzed retrospectively. All the patients have not been found the original site in the initial treatment. There are four quadrants in the neck, the neck line as the longitudinal axis, and edge of cricoid cartilage as the horizontal axis. When cervical metastasis occurred in the left and right upper quadrant, the primary tumor site and radiotherapy from the skull base to the root of the neck; when appear in left and right lower quadrant, the primary investigation site and radiotherapy from neck to thoracic mediastinum, left lower abdomen also includes following primary search. At the same time, bilateral cervical metastasis cancers, focusing on the central line near the primary focus. Specific treatment strategies include ipsilateral total neck dissection and radical radiotherapy of the above radiotherapy site. Result: Left upper neck in 4 cases, right upper neck in 5 cases, left lower neck in 7 cases, lower right neck in 8 cases and mixed area in 6 cases. Only 10 of 30 patients (33.3%) with primary sites were found in the follow up period. In accordance with the four quadrant localization, the median time was 6 months. Conclusion: Four quadrant localization to locate the primary site is accurate, and individualized comprehensive treatment is the key to improve the curative effect. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.
Escalona-Vargas, Diana; Govindan, Rathinaswamy B; Furdea, Adrian; Murphy, Pam; Lowery, Curtis L; Eswaran, Hari
2015-01-01
The objective of this study was to quantify the number of segments that have contractile activity and determine the propagation speed from uterine electrophysiological signals recorded over the abdomen. The uterine magnetomyographic (MMG) signals were recorded with a 151 channel SARA (SQUID Array for Reproductive Assessment) system from 36 pregnant women between 37 and 40 weeks of gestational age. The MMG signals were scored and segments were classified based on presence of uterine contractile burst activity. The sensor space was then split into four quadrants and in each quadrant signal strength at each sample was calculated using center-of-gravity (COG). To this end, the cross-correlation analysis of the COG was performed to calculate the delay between pairwise combinations of quadrants. The relationship in propagation across the quadrants was quantified and propagation speeds were calculated from the delays. MMG recordings were successfully processed from 25 subjects and the average values of propagation speeds ranged from 1.3-9.5 cm/s, which was within the physiological range. The propagation was observed between both vertical and horizontal quadrants confirming multidirectional propagation. After the multiple pairwise test (99% CI), significant differences in speeds can be observed between certain vertical or horizontal combinations and the crossed pair combinations. The number of segments containing contractile activity in any given quadrant pair with a detectable delay was significantly higher in the lower abdominal pairwise combination as compared to all others. The quadrant-based approach using MMG signals provided us with high spatial-temporal information of the uterine contractile activity and will help us in the future to optimize abdominal electromyographic (EMG) recordings that are practical in a clinical setting.
Escalona-Vargas, Diana; Govindan, Rathinaswamy B.; Furdea, Adrian; Murphy, Pam; Lowery, Curtis L.; Eswaran, Hari
2015-01-01
The objective of this study was to quantify the number of segments that have contractile activity and determine the propagation speed from uterine electrophysiological signals recorded over the abdomen. The uterine magnetomyographic (MMG) signals were recorded with a 151 channel SARA (SQUID Array for Reproductive Assessment) system from 36 pregnant women between 37 and 40 weeks of gestational age. The MMG signals were scored and segments were classified based on presence of uterine contractile burst activity. The sensor space was then split into four quadrants and in each quadrant signal strength at each sample was calculated using center-of-gravity (COG). To this end, the cross-correlation analysis of the COG was performed to calculate the delay between pairwise combinations of quadrants. The relationship in propagation across the quadrants was quantified and propagation speeds were calculated from the delays. MMG recordings were successfully processed from 25 subjects and the average values of propagation speeds ranged from 1.3–9.5 cm/s, which was within the physiological range. The propagation was observed between both vertical and horizontal quadrants confirming multidirectional propagation. After the multiple pairwise test (99% CI), significant differences in speeds can be observed between certain vertical or horizontal combinations and the crossed pair combinations. The number of segments containing contractile activity in any given quadrant pair with a detectable delay was significantly higher in the lower abdominal pairwise combination as compared to all others. The quadrant-based approach using MMG signals provided us with high spatial-temporal information of the uterine contractile activity and will help us in the future to optimize abdominal electromyographic (EMG) recordings that are practical in a clinical setting. PMID:26505624
A new color vision test to differentiate congenital and acquired color vision defects.
Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak
2007-07-01
To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.
1992-12-01
ecliptic longitude changed from -2100 to -2600 over the course of the IRAS mission. Thus, in these plots it would be located in the lower left quadrant ...degrees ecliptic longitude is towards the top of this plot. During the 1983 IRAS mission, Jupiter was in the lower left quadrant near an ecliptic...Most hot stars and cold background sources are outside the range of this color window (cf., lower right quadrant of Fig. 15). The 12 pm to 25 prm
An efficient indexing scheme for binary feature based biometric database
NASA Astrophysics Data System (ADS)
Gupta, P.; Sana, A.; Mehrotra, H.; Hwang, C. Jinshong
2007-04-01
The paper proposes an efficient indexing scheme for binary feature template using B+ tree. In this scheme the input image is decomposed into approximation, vertical, horizontal and diagonal coefficients using the discrete wavelet transform. The binarized approximation coefficient at second level is divided into four quadrants of equal size and Hamming distance (HD) for each quadrant with respect to sample template of all ones is measured. This HD value of each quadrant is used to generate upper and lower range values which are inserted into B+ tree. The nodes of tree at first level contain the lower and upper range values generated from HD of first quadrant. Similarly, lower and upper range values for the three quadrants are stored in the second, third and fourth level respectively. Finally leaf node contains the set of identifiers. At the time of identification, the test image is used to generate HD for four quadrants. Then the B+ tree is traversed based on the value of HD at every node and terminates to leaf nodes with set of identifiers. The feature vector for each identifier is retrieved from the particular bin of secondary memory and matched with test feature template to get top matches. The proposed scheme is implemented on ear biometric database collected at IIT Kanpur. The system is giving an overall accuracy of 95.8% at penetration rate of 34%.
National Culture in Practice: Its Impact on Knowledge Sharing in Global Virtual Collaboration
ERIC Educational Resources Information Center
Wei, Kangning
2009-01-01
Issues concerning global virtual collaboration have received considerable attention in both the academic and practical world; however, little research has been conducted on knowledge-sharing activities in global virtual collaboration, which is a key process to achieve collaboration effectiveness. Due to national culture having been seen as one of…
Vertical structure of aeolian turbulence in a boundary layer with sand transport
NASA Astrophysics Data System (ADS)
Lee, Zoe S.; Baas, Andreas C. W.
2016-04-01
Recently we have found that Reynolds shear stress shows a significant variability with measurement height (Lee and Baas, 2016), and so an alternative parameter for boundary layer turbulence may help to explain the relationship between wind forcing and sediment transport. We present data that were collected during a field study of boundary layer turbulence conducted on a North Atlantic beach. High-frequency (50 Hz) 3D wind velocity measurements were collected using ultrasonic anemometry at thirteen different measurement heights in a tight vertical array between 0.11 and 1.62 metres above the surface. Thanks to the high density installation of sensors a detailed analysis of the boundary layer flow can be conducted using methods more typically used in studies where data is only available from one or just a few measurement heights. We use quadrant analysis to explore the vertical structure of turbulence and track the changes in quadrant signatures with measurement elevation and over time. Results of quadrant analysis, at the 'raw' 50 Hz timescale, demonstrates the tendency for event clustering across all four quadrants, which implies that at-a-point quadrant events are part of larger-scale turbulent structures. Using an HSV colour model, applied to the quadrant analysis data and plotted in series, we create colour maps of turbulence, which can provide a clear visualisation of the clustering of event activity at each height and illustrate the shape of the larger coherent flow structures that are present within the boundary layer. By including a saturation component to the colour model, the most significant stress producing sections of the data are emphasised. This results in a 'banded' colour map, which relates to clustering of quadrant I (Outward Interaction) and quadrant IV (Sweep) activity, separate from clustering of quadrant II (Burst) and quadrant III (Inward Interaction). Both 'sweep-type' and 'burst-type' sequences are shown to have a diagonal structure originating from the top of the boundary layer, indicating a downwards direction of eddy motion. While directionality of turbulence cannot be definitively determined, our results indicate that the top-down turbulence model is a suitable explanation, further supported by the presence of 'incomplete' eddies which originate at higher elevations but fail to extend to the surface. This provides the first evidence in support of a top down turbulence model as observed in aeolian geomorphology, and we present preliminary findings on its relationship to sand transport activity. Lee, Z.S., Baas, A.C.W. (2016) Variable and conflicting shear stress estimates inside a boundary layer with sediment transport. Earth Surface Processes and Landforms; DOI: 10.1002/esp.3829
Turbulent Reynolds stress and quadrant event activity in wind flow over a coastal foredune
NASA Astrophysics Data System (ADS)
Chapman, Connie A.; Walker, Ian J.; Hesp, Patrick A.; Bauer, Bernard O.; Davidson-Arnott, Robin G. D.
2012-05-01
Recent research on quasi-instantaneous turbulent kinematic Reynolds stresses (RS, - u'w') and decomposed quadrant event activity (e.g., ejections and sweeps) over dunes in fluvial settings and in wind tunnels has shown that turbulent stresses at the toe of a dune often exceed time-averaged, streamwise shear stress (ρ u * 2) estimates. It is believed that semi-coherent turbulent structures are conveyed toward the bed along concave streamlines in this region and that impact of these structures cause fluctuations in local surface stresses that assist in grain entrainment. This has been hypothesized to explain how sand is supplied to the windward slope through a region of flow stagnation. Toward the crest, surface stress increases and becomes dominated by streamwise accelerations resulting from streamline compression and convexity that suppress vertical motions. High-frequency (32 Hz) measurements of turbulent wind flow from 3-D ultrasonic anemometers are analyzed for oblique onshore flow over a vegetated coastal foredune in Prince Edward Island, Canada. Reynolds stress and quadrant activity distributions varied with height (0.60 m and 1.66 m) and location over the dune. In general, quadrant 2 ejection (u' < 0, w' > 0) and quadrant 4 sweep activity (u' > 0, w' < 0) dominated momentum transfer and RS generation over quadrant 1 outward interaction (u' > 0, w' > 0) and quadrant 3 inward interaction (u' < 0, w' < 0) activity. On the lower stoss slope, significant ejection and sweep event activity was most frequent (85 to 92%, ejections plus sweeps), whereas, at the upper crest, significant ejection and sweep activity became less frequent while significant outward and inward interactions increased in frequency (25 to 36%). An 'exuberance effect' (i.e., changing shape of quadrant frequency distribution skewed toward ejection and sweep activity) is observed whereby streamline compression and convexity effects inhibit vertical fluctuations in flow and, thus, reduce the frequency of ejections and sweep activity toward the crest. In separated flow in the lee of the crest, quadrant distributions were more symmetrical as a result of more mixed, multi-directional flow. These trends in turbulent event distributions and Reynolds stress have implications for sediment transport dynamics across the dune and may help to explain sand transport potential and dune maintenance. For example, areas with a high frequency of ejection and sweep activity may have higher rates of sediment entrainment and transport, whereas areas with lower ejection and sweep activity and an increase in outward and inward interactions, which contribute negatively to Reynolds stress generation, may experience a greater potential for deposition. Further research on associations between quadrant event activity and coincident sand transport is required to confirm this hypothesis and the resultant significance of the flow exuberance effect in aeolian dune morphodynamics.
High data rate optical transceiver terminal
NASA Technical Reports Server (NTRS)
Clarke, E. S.
1973-01-01
The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.
Fajnerová, Iveta; Rodriguez, Mabel; Levčík, David; Konrádová, Lucie; Mikoláš, Pavol; Brom, Cyril; Stuchlík, Aleš; Vlček, Kamil; Horáček, Jiří
2014-01-01
Objectives: Cognitive deficit is considered to be a characteristic feature of schizophrenia disorder. A similar cognitive dysfunction was demonstrated in animal models of schizophrenia. However, the poor comparability of methods used to assess cognition in animals and humans could be responsible for low predictive validity of current animal models. In order to assess spatial abilities in schizophrenia and compare our results with the data obtained in animal models, we designed a virtual analog of the Morris water maze (MWM), the virtual Four Goals Navigation (vFGN) task. Methods: Twenty-nine patients after the first psychotic episode with schizophrenia symptoms and a matched group of healthy volunteers performed the vFGN task. They were required to find and remember four hidden goal positions in an enclosed virtual arena. The task consisted of two parts. The Reference memory (RM) session with a stable goal position was designed to test spatial learning. The Delayed-matching-to-place (DMP) session presented a modified working memory protocol designed to test the ability to remember a sequence of three hidden goal positions. Results: Data obtained in the RM session show impaired spatial learning in schizophrenia patients compared to the healthy controls in pointing and navigation accuracy. The DMP session showed impaired spatial memory in schizophrenia during the recall of spatial sequence and a similar deficit in spatial bias in the probe trials. The pointing accuracy and the quadrant preference showed higher sensitivity toward the cognitive deficit than the navigation accuracy. Direct navigation to the goal was affected by sex and age of the tested subjects. The age affected spatial performance only in healthy controls. Conclusions: Despite some limitations of the study, our results correspond well with the previous studies in animal models of schizophrenia and support the decline of spatial cognition in schizophrenia, indicating the usefulness of the vFGN task in comparative research. PMID:24904329
Jay, Raman; Heckman, J E; Hinshaw, L; Best, S; Lubner, M; Jarrard, D F; Downs, T M; Nakada, S Y; Lee, F T; Huang, W; Ziemlewicz, T
2017-03-01
Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs. a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10cm (IQR: 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (P = 0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs. 2 of 8 (25.0%) (P = 0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2017. Published by Elsevier Inc.
Chintala, Kalyan; Kumar, Sandhya Pavan; Murthy, K Raja V
2017-01-01
Pain control is an important outcome measure for successful periodontal therapy. Injected local anesthesia has been used to secure anesthesia for scaling and root planing (SRP) and continues to be the anesthetic of choice for pain control. Alternatively, intra-pocket anesthetic gel has been used as an anesthetic during SRP. Hence, this clinical trial was done to compare the effectiveness of intra-pocket anesthetic gel and injected local anesthesia during SRP and also to assess the influence of intra-pocket anesthetic gel on treatment outcomes in chronic periodontitis patients. Fifteen systemically healthy chronic periodontitis patients were recruited. The dental quadrants on right side received either intra-pocket 20% benzocaine gel (Gel group) or infiltration/block by 2% lidocaine with 1:80,000 adrenaline (injection group). Quadrants on the left side received the alternative. Pain perception and patients preference for the type of anesthesia was recorded. Clinical parameters: plaque index, modified gingival index, modified sulcular bleeding index, probing pocket depth, and clinical attachment level were recorded at baseline and 1 month after treatment. No difference was observed in visual analog scale (P > 0.05) and verbal rating scale (P > 0.05) pain perception between gel group and injection group. A slightly increased preference to gel as anesthesia (53% vs. 47%) was observed. The treatment outcome after SRP did not show a significant difference between gel and injection group (P > 0.05). Intra-pocket administration of 20% benzocaine gel may be effective for pain control during SRP and may offer an alternative to conventional injection anesthesia.
Relation of sound intensity and accuracy of localization.
Farrimond, T
1989-08-01
Tests were carried out on 17 subjects to determine the accuracy of monaural sound localization when the head is not free to turn toward the sound source. Maximum accuracy of localization for a constant-volume sound source coincided with the position for maximum perceived intensity of the sound in the front quadrant. There was a tendency for sounds to be perceived more often as coming from a position directly toward the ear. That is, for sounds in the front quadrant, errors of localization tended to be predominantly clockwise (i.e., biased toward a line directly facing the ear). Errors for sounds occurring in the rear quadrant tended to be anticlockwise. The pinna's differential effect on sound intensity between front and rear quadrants would assist in identifying the direction of movement of objects, for example an insect, passing the ear.
Interpersonal Subtypes and Therapy Response in Patients Treated for Posttraumatic Stress Disorder.
König, Julia; Onnen, Margarete; Karl, Regina; Rosner, Rita; Butollo, Willi
2016-01-01
Interpersonal traits may influence psychotherapy success. One way of conceptualizing such traits is the interpersonal circumplex model. In this study, we analyse interpersonal circumplex data, assessed with the Inventory of Interpersonal Problems (Horowitz, Strauß, & Kordy, 1994) from a randomized study with 138 patients suffering from posttraumatic stress disorder after trauma in adulthood. The study compared cognitive processing therapy and dialogical exposure therapy, a Gestalt-based intervention. We divided the interpersonally heterogeneous sample according to the quadrants of the interpersonal circumplex. The division into quadrants yielded subgroups that did not differ in their general psychological distress, but the cold-submissive quadrant tended to exhibit higher posttraumatic stress disorder symptom severity and interpersonal distress than the other three. There was also a trend for patients in different quadrants to be affected differently by the treatments. Correlation analyses supported these results: in cognitive processing therapy, more dominant patients had more successful therapies, while in dialogical exposure therapy, success was not correlated with interpersonal style. Results indicate that especially patients with cold interpersonal styles profited differentially from the two treatments offered. Dividing samples according to the interpersonal circumplex quadrants seems promising. Interpersonal traits may contribute to psychotherapy outcome. Dividing the sample according to the quadrants of the interpersonal circumplex, as opposed to cluster analysis, yielded promising results. Patients higher in dominance fared better with cognitive processing therapy, while interpersonal style had no correlations with therapy success in dialogical exposure therapy. Copyright © 2015 John Wiley & Sons, Ltd.
A Highly Linear and Wide Input Range Four-Quadrant CMOS Analog Multiplier Using Active Feedback
NASA Astrophysics Data System (ADS)
Huang, Zhangcai; Jiang, Minglu; Inoue, Yasuaki
Analog multipliers are one of the most important building blocks in analog signal processing circuits. The performance with high linearity and wide input range is usually required for analog four-quadrant multipliers in most applications. Therefore, a highly linear and wide input range four-quadrant CMOS analog multiplier using active feedback is proposed in this paper. Firstly, a novel configuration of four-quadrant multiplier cell is presented. Its input dynamic range and linearity are improved significantly by adding two resistors compared with the conventional structure. Then based on the proposed multiplier cell configuration, a four-quadrant CMOS analog multiplier with active feedback technique is implemented by two operational amplifiers. Because of both the proposed multiplier cell and active feedback technique, the proposed multiplier achieves a much wider input range with higher linearity than conventional structures. The proposed multiplier was fabricated by a 0.6µm CMOS process. Experimental results show that the input range of the proposed multiplier can be up to 5.6Vpp with 0.159% linearity error on VX and 4.8Vpp with 0.51% linearity error on VY for ±2.5V power supply voltages, respectively.
Beheshti, Farimah; Karimi, Sareh; Vafaee, Farzaneh; Shafei, Mohammad Naser; Sadeghnia, Hamid Reza; Hadjzadeh, Mosa Al Reza; Hosseini, Mahmoud
2017-06-01
In this study the effects of Vitamin C (Vit C) on hypothyroidism-associated learning and memory impairment in juvenile rats was investigated. The pregnant rats were kept in separate cages. After delivery, they were randomly divided into six groups and treated: (1) Control; (2) Propylthiouracil (PTU) which 0.005% PTU in their drinking; (3-5) Propylthiouracil- Vit C groups; besides PTU, dams in these groups received 10, 100 and 500 mg/kg Vit C respectively, (6) one group as a positive control; the intact rats received an effective dose, 100 mg/kg Vit. C. After delivery, the pups were continued to receive the experimental treatments in their drinking water up to 56th day of their life. Ten male offspring of each group were randomly selected and tested in the Morris water maze (MWM) and passive avoidance (PA) which were started at 63th day (one week after stopping of the treatments). Brains were then removed for biochemical measurements. PTU increased time latency and traveled distance during 5 days in MWM while, reduced the spent time in target quadrant in MWM and step-trough latency (STL) in PA. PTU decreased thiol content, superoxide dismutase (SOD) and catalase (CAT) activities in the brain while, increased molondialdehyde (MDA). In MWM test, 10, 100 and 500 mg/kg Vit C reduced time latency and traveled distance without affecting the traveling speed during 5 days. All doses of Vit C increased the spent time in target quadrant in probe trail of MWM and also increased STL in PA test. Vit C increased thiol, SOD and CAT in the brain tissues while, reduced MDA. Results of present study confirmed the beneficial effects of Vit C on learning and memory. It also demonstrated that Vit C has protective effects on hypothyroidism-associated learning and memory impairment in juvenile rats which might be elucidated by the antioxidative effects.
Evaluating the Patient with Left Lower Quadrant Abdominal Pain.
Bodmer, Nicholas A; Thakrar, Kiran H
2015-11-01
Left lower quadrant pain is a frequent indication for imaging in the emergency department. Most causes of pain originate from the colon, including diverticulitis, colitis, fecal impaction, and epiploic appendagitis. Left-sided urolithiasis and spontaneous hemorrhage in the retroperitoneum or rectus sheath are additional causes of pain. Computed tomography is the preferred imaging modality in the emergent setting for all of these pathologic conditions. Gynecologic, testicular, and neoplastic pathology may also cause left lower quadrant pain but are not discussed in this article. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Lin; Zou, Jun; Huang, Hui; Yang, Jian-guo; Chen, Shao-rong
2012-05-23
To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was -1.17 diopters (D; SD 0.64; range -0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was -0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of -1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895.
McKay, Gareth J; Clarke, Stephen; Davis, Jason A; Simpson, David A C; Silvestri, Giuliana
2005-01-01
Pigmented paravenous chorioretinal atrophy (PPCRA) is an unusual retinal degeneration characterized by accumulation of pigmentation along retinal veins. The purpose of this study was to describe the phenotype of a family with PPCRA, determine the mode of inheritance, and identify the causal mutation. Ophthalmic examination was performed on seven family members and serially detailed in the proband over a 3-year period. Blood samples were collected and DNA extracted. All 12 coding exons and the 5' promoter region of the crumbs homologue 1 (CRB1) gene were PCR amplified and DNA sequenced. In silico homology modeling was performed on the mutated protein domain. Subtle symmetrical chorioretinal atrophy in the inferior quadrant was the earliest clinical sign detectable within this family. Paravenous pigmentation occurred initially in the far periphery, progressing centrally, with atrophy later becoming more widespread, involving the nasal, then the temporal, and finally the upper quadrant. A novel, dominant Val162Met mutation within the fourth EGF-like domain of CRB1 cosegregates with the PPCRA phenotype. It is thought to affect domain structure, because codon 162 is involved in hydrogen bonding between the antiparallel beta-strands of the major beta-sheet, causing sufficient perturbation of the backbone that the domain-stabilizing hydrogen bond does not form or is weakened. PPCRA was dominantly inherited in this family, but exhibited variable expressivity. Males are more likely to exhibit a severe phenotype, whereas females may remain virtually asymptomatic even in later years. The PPCRA phenotype is associated with a Val162Met mutation in CRB1 which is likely to affect the structure of the CRB1 protein.
Ahn, Sun Joo Grace; Johnsen, Kyle; Moore, James; Brown, Scott; Biersmith, Melanie; Ball, Catherine
2016-02-01
A virtual pet in the form of a mid-sized dog was developed based on the framework of social cognitive theory and tested as a vehicle for promoting fruit and vegetable (F&V) consumption in children. Three groups of children (N = 68) between the ages of 7 and 13 years were studied: baseline (no treatment), computer only, and virtual dog. Children in the virtual dog condition interacted with the virtual dog for 3 days, setting F&V consumption goals and receiving evaluation and reinforcement based on whether they met their self-set goals. Children vicariously experienced future health outcomes of F&V consumption by seeing, hearing, and feeling their virtual dog's physical and mental health improve or deteriorate based on their F&V consumption in the physical world. Children in the computer only condition interacted with a computer system that presented equivalent features, but without the virtual dog. Children in the baseline condition did not receive any experimental treatment. Results indicated that children in the virtual dog condition chose to be served significantly more F&V than those in the computer only or baseline conditions did. However, children in the virtual dog condition were unable to consume significantly more F&V than those in the computer only condition, although children in those two conditions consumed more F&V than the baseline condition. Food preferences did not differ significantly across the three conditions before and after the experimental treatments. Theoretical and practical potentials of using a virtual pet to promote F&V consumption systematically in children are discussed.
Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.
Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin
2015-12-01
To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline. Copyright © 2015 American Academy of Ophthalmology. All rights reserved.
Survey of Nerve Fiber Layer Thickness in Anisometropic and Strabismic Amblyopia.
Soltani Moghaddam, Reza; Medghalchi, Abdolreza; Alizadeh, Yousef
2017-01-01
. To investigate the effect of anisometropic and strabismic amblyopia on the nerve fiber layer thickness. This cross-sectional study was done on 54 amblyopic subjects, equally in both strabismic and anisometropic groups. The thickness otonerve fiber layer measured in superior, inferior, nasal, temporal quadrants and as a whole in both eyes of both groups. The means of thickness were compared in amblyopic and sound eyes. In strabismus group, the average nerve fiber layer thickness of the sound eye , in superior, inferior, nasal and temporal quadrants and as a whole were 113.23±14, 117.37±25, 68.96±6, 69.55±14 and 93.40±8 microns respectively. In amblyopic eyes of the same group, these measurements were 103.11±18, 67.74±11, and 69.59±16 and 89.59±12 microns in superior, inferior, nasal, temporal quadrants and as whole respectively. In anisometropic groups, the sound eye measurements were as 130.96±22, 129.07±29, 80.62±12, and 83.88±20 and 107.7±13 microns in superior, inferior, nasal and temporal quadrants and as a whole orderly. In amblyopic eyes of this group the mean thicknesses were 115.63±29, 133.15±25, 78.8±15, 80.2±16 and 109.17±21 microns in superior, inferior, nasal, temporal quadrants and as a whole respectively. Statistically, there were no significant differences between amblyopic and sound eyes (P>0.5). Our study did not support any significant change in a nerve fiber layer thickness of amblyopic patients; however, decreased thickness in superior and nasal quadrants of strabismic amblyopia and except inferior quadrant and as a whole. These measurements may be a clue for management and prognosis of amblyopia in old age.
Distance comparisons in virtual reality: effects of path, context, and age
van der Ham, Ineke J. M.; Baalbergen, Heleen; van der Heijden, Peter G. M.; Postma, Albert; Braspenning, Merel; van der Kuil, Milan N. A.
2015-01-01
In this large scale, individual differences study (N = 521), the effects of cardinal axes of an environment and the path taken between locations on distance comparisons were assessed. The main goal was to identify if and to what extent previous findings in simple 2D tasks can be generalized to a more dynamic, three-dimensional virtual reality environment. Moreover, effects of age and gender were assessed. After memorizing the locations of six objects in a circular environment, participants were asked to judge the distance between objects they encountered. Results indicate that categorization (based on the cardinal axes) was present, as distances within one quadrant were judged as being closer together, even when no visual indication of the cardinal axes was given. Moreover, strong effects of the path taken between object locations were found; objects that were near on the path taken were perceived as being closer together than objects that were further apart on this path, regardless of the metric distance between the objects. Males outperformed females in distance comparison, but did not differ in the extent of the categorization and path effects. Age also affected performance; the categorization and path effects were highly similar across the age range tested, but the general ability to estimate distances does show a clear pattern increase during development and decrease with aging. PMID:26321968
59. VIEW FROM THE NORTHEAST IN THE NORTHEAST QUADRANT. GENERAL ...
59. VIEW FROM THE NORTHEAST IN THE NORTHEAST QUADRANT. GENERAL VIEW OF THE RIGHT FLANK WALL. RIGHT SHOULDER ANGLE IS INCLUDED ON THE RIGHT SIDE OF THE PHOTOGRAPH. - Fort Sumter, Charleston, Charleston County, SC
Illinois high-speed rail four-quadrant gate reliability assessment
DOT National Transportation Integrated Search
2009-10-01
The Federal Railroad Administration (FRA) tasked the John A. Volpe National Transportation Systems Center (Volpe Center) to conduct a reliability analysis of the four-quadrant gate/vehicle detection equipment installed on the future high-speed rail (...
Code of Federal Regulations, 2011 CFR
2011-04-01
... N.-T. 16 N. township line), the boundary runs northwest to the northeastern corner of quadrant 4, on the T. 18 N.-T. 17 N. township line; (2) Then west to the northwest corner of quadrant 1; (3) Then...
Code of Federal Regulations, 2010 CFR
2010-04-01
... N.-T. 16 N. township line), the boundary runs northwest to the northeastern corner of quadrant 4, on the T. 18 N.-T. 17 N. township line; (2) Then west to the northwest corner of quadrant 1; (3) Then...
NASA Astrophysics Data System (ADS)
Manojlović, Stojadin M.; Barbarić, Žarko P.; Mitrović, Srđan T.
2015-06-01
A new tracking design for laser systems with different arrangements of a quadrant photodetector, based on the principle of active disturbance rejection control is suggested. The detailed models of quadrant photodetector with standard add-subtract, difference-over-sum and diagonal-difference-over-sum algorithms for displacement signals are included in the control loop. Target moving, non-linearity of a photodetector, parameter perturbations and exterior disturbances are treated as a total disturbance. Active disturbance rejection controllers with linear extended state observers for total disturbance estimation and rejection are designed. Proposed methods are analysed in frequency domain to quantify their stability characteristics and disturbance rejection performances. It is shown through simulations, that tracking errors are effectively compensated, providing the laser spot positioning in the area near the centre of quadrant photodetector where the mentioned algorithms have the highest sensitivity, which provides tracking of the manoeuvring targets with high accuracy.
ERIC Educational Resources Information Center
Vernon, Nichole
2013-01-01
The purpose of this study was to examine the success of students in Exceptional Education in Tennessee Virtual Academy. Students participating in this study are in grades 5-8, have a diagnosis of Specific Learning Disabilities, residents of Tennessee, currently enrolled in Tennessee Virtual Academy, and received Exceptional Education services.…
Jump, Robin L.; Banks, Richard; Wilson, Brigid; Montpetite, Michelle M.; Carter, Rebecca; Phillips, Susan; Perez, Federico
2015-01-01
We developed a “virtual clinic” to improve pneumococcal vaccination among asplenic adults. Using an electronic medical record, we identified patients, assessed their vaccination status, entered orders, and notified patients and providers. Within 180 days, 38 of 76 patients (50%) received a pneumococcal vaccination. A virtual clinic may optimize vaccinations among high-risk patients. PMID:26668815
ERIC Educational Resources Information Center
Ryan, Jenna; Porter, Marjorie; Miller, Rebecca
2010-01-01
Current literature on libraries is abundant with articles about the uses and the potential of new interactive communication technology, including Web 2.0 tools. Recently, the advent and use of virtual worlds have received top billing in these works. Many library institutions are exploring these virtual environments; this exploration and the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tikotekar, Anand A; Vallee, Geoffroy R; Naughton III, Thomas J
2008-01-01
The topic of system-level virtualization has recently begun to receive interest for high performance computing (HPC). This is in part due to the isolation and encapsulation offered by the virtual machine. These traits enable applications to customize their environments and maintain consistent software configurations in their virtual domains. Additionally, there are mechanisms that can be used for fault tolerance like live virtual machine migration. Given these attractive benefits to virtualization, a fundamental question arises, how does this effect my scientific application? We use this as the premise for our paper and observe a real-world scientific code running on a Xenmore » virtual machine. We studied the effects of running a radiative transfer simulation, Hydrolight, on a virtual machine. We discuss our methodology and report observations regarding the usage of virtualization with this application.« less
Endoscopic vs. tactile evaluation of subgingival calculus.
Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M
2014-08-01
Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (p<0.005). Mean changes (reduction) in calculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (p<0.0001). However, further reductions in calculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (p<0.025), indicating that this methodology was able to more precisely detect calculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.
Kinky thresholds revisited: opportunity costs differ in the NE and SW quadrants.
Eckermann, Simon
2015-02-01
Historically, a kinked threshold line on the cost-effectiveness plane at the origin was suggested due to differences in willingness to pay (WTP) for health gain with trade-offs in the north-east (NE) quadrant versus willingness to accept (WTA) cost reductions for health loss with trade-offs in the south-west (SW) quadrant. Empirically, WTA is greater than WTP for equivalent units of health, a finding supported by loss aversion under prospect theory. More recently, appropriate threshold values for health effects have been shown to require an endogenous consideration of the opportunity cost of alternative actions in budget-constrained health systems, but also allocative and displacement inefficiency observed in health system practice. Allocative and displacement inefficiency arise in health systems where the least cost-effective program in contraction has a higher incremental cost-effectiveness ratio (ICER = m) than the most cost-effective program in expansion (ICER = n) and displaced services (ICER = d), respectively. The health shadow price derived by Pekarsky, [Formula: see text] reflects the opportunity cost of best alternative adoption and financing actions in reimbursing new technology with expected incremental costs and net effect allowing for allocative (n < m), and displacement, inefficiency (d < m). This provides an appropriate threshold value for the NE quadrant. In this paper, I show that for trade-offs in the SW quadrant, where new strategies have lower expected net cost while lower expected net effect than current practice, the opportunity cost is contraction of the least cost-effective program, with threshold ICER m. That is, in the SW quadrant, the cost reduction per unit of decreased effect should be compared with the appropriate opportunity cost, best alternative generation of funding. Consequently, appropriate consideration of opportunity cost produces a kink in the threshold at the origin, with the health shadow price in the NE quadrant and ICER of the least cost-effective program in contraction (m) in the SW quadrant having the same general shape as that previously suggested by WTP versus WTA. The extent of this kink depends on the degree of allocative and displacement inefficiency, with no kink in the threshold line strictly only appropriate with complete allocative and displacement efficiency, that is n = d = m.
Dutra, Lauren McCarl; Nonnemaker, James; Taylor, Nathaniel; Kim, Annice E
2018-06-29
Virtual stores can be used to identify influences on consumer shopping behavior. Deception is one technique that may be used to attempt to increase the realism of virtual stores. The objective of the experiment was to test whether the purchasing behavior of participants in a virtual shopping task varied based on whether they were told that they would receive the products they selected in a virtual convenience store (a form of deception) or not. We recruited a US national sample of 402 adult current smokers by email from an online panel of survey participants. They completed a fully automated randomized virtual shopping experiment with a US $15 or US $20 budget in a Web-based virtual convenience store. We told a random half of participants that they would receive the products they chose in the virtual store or the cash equivalent (intervention condition), and the other random half simply to conduct a shopping task (control condition). We tested for differences in demographics, tobacco use behaviors, and in-store purchases (outcome variable, assessed by questionnaire) by experimental condition. The characteristics of the participants (398/402, 99.0% with complete data) were comparable across conditions except that the intervention group contained slightly more female participants (103/197, 52.3%) than the control group (84/201, 41.8%; P=.04). We did not find any other significant differences in any other demographic variables or tobacco use, or in virtual store shopping behaviors, including purchasing any tobacco (P=.44); purchasing cigarettes (P=.16), e-cigarettes (P=.54), cigars (P=.98), or smokeless tobacco (P=.72); amount spent overall (P=.63) or on tobacco (P=.66); percentage of budget spent overall (P=.84) or on tobacco (P=.74); number of total items (P=.64) and tobacco items purchased (P=.54); or total time spent in the store (P=.07). We found that telling participants that they will receive the products they select in a virtual store did not influence their purchases. This finding suggests that deception may not affect consumer behavior and, as a result, may not be necessary in virtual shopping experiments. ©Lauren McCarl Dutra, James Nonnemaker, Nathaniel Taylor, Annice E Kim. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 29.06.2018.
Delay-based virtual congestion control in multi-tenant datacenters
NASA Astrophysics Data System (ADS)
Liu, Yuxin; Zhu, Danhong; Zhang, Dong
2018-03-01
With the evolution of cloud computing and virtualization, the congestion control of virtual datacenters has become the basic issue for multi-tenant datacenters transmission. Regarding to the friendly conflict of heterogeneous congestion control among multi-tenant, this paper proposes a delay-based virtual congestion control, which translates the multi-tenant heterogeneous congestion control into delay-based feedback uniformly by setting the hypervisor translation layer, modifying three-way handshake of explicit feedback and packet loss feedback and throttling receive window. The simulation results show that the delay-based virtual congestion control can effectively solve the unfairness of heterogeneous feedback congestion control algorithms.
64. VIEW FROM THE NORTHEAST IN THE NORTHEAST QUADRANT. DETAIL ...
64. VIEW FROM THE NORTHEAST IN THE NORTHEAST QUADRANT. DETAIL VIEW OF THE RIGHT FACE. A PORTION OF THE RIGHT SHOULDER ANGLE IS INCLUDED ON THE LEFT-SIDE OF THE IMAGE, WITH SCALE. - Fort Sumter, Charleston, Charleston County, SC
Self-assessing target with automatic feedback
Larkin, Stephen W.; Kramer, Robert L.
2004-03-02
A self assessing target with four quadrants and a method of use thereof. Each quadrant containing possible causes for why shots are going into that particular quadrant rather than the center mass of the target. Each possible cause is followed by a solution intended to help the marksman correct the problem causing the marksman to shoot in that particular area. In addition, the self assessing target contains possible causes for general shooting errors and solutions to the causes of the general shooting error. The automatic feedback with instant suggestions and corrections enables the shooter to improve their marksmanship.
Nuclear Graphite - Fracture Behavior and Modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burchell, Timothy D; Battiste, Rick; Strizak, Joe P
2011-01-01
Evidence for the graphite fracture mechanism is reviewed and discussed. The roles of certain microstructural features in the graphite fracture process are reported. The Burchell fracture model is described and its derivation reported. The successful application of the fracture model to uniaxial tensile data from several graphites with widely ranging structure and texture is reported. The extension of the model to multiaxial loading scenarios using two criteria is discussed. Initially, multiaxial strength data for H-451 graphite were modeled using the fracture model and the Principle of Independent Action. The predicted 4th stress quadrant failure envelope was satisfactory but the 1stmore » quadrant predictions were not conservative and thus were unsatisfactory. Multiaxial strength data from the 1st and 4th stress quadrant for NBG-18 graphite are reported. To improve the conservatism of the predicted 1st quadrant failure envelope for NBG-18 the Shetty criterion has been applied to obtain the equivalent critical stress intensity factor, KIc (Equi), for each applied biaxial stress ratio. The equivalent KIc value is used in the Burchell fracture model to predict the failure envelope. The predicted 1st stress quadrant failure envelope is conservative and thus more satisfactory than achieved previously using the fracture model combined with the Principle of Independent Action.« less
Prins, Yolandi; Crous, Lynette; Louw, Q A
2008-01-01
Musculoskeletal pain has become a major symptomatic complaint among children and adolescents and is increasingly occurring at a younger age. This systematic review was done to evaluate the evidence for the contribution of posture and psychosocial factors to the development of upper quadrant musculoskeletal pain in children and adolescents. The review describes the measurement tools used to assess musculoskeletal pain, sitting posture, and psychosocial factors. Two independent reviewers searched seven databases for observational studies that included prospective and cross-sectional study designs. Ten studies were extracted and assessed by two reviewers using the Critical Appraisal Form-Quantitative Studies (Law et al, 1998). The studies measured upper quadrant musculoskeletal pain as an outcome measure. Five studies evaluated sitting posture and found an association between the duration of static sitting and upper quadrant musculoskeletal pain. Six studies measured psychosocial factors of which depression, stress, and psychosomatic symptoms were the factors most commonly found to influence the development of upper quadrant musculoskeletal pain. The eligible studies used different pain measurement tools and different measurement tools to assess sitting posture and psychosocial factors. This review concludes that the duration of sitting posture and psychosocial factors may influence the experience of musculoskeletal pain among children and adolescents.
Genesis Silicon Carbide Concentrator Target 60003 Preliminary Ellipsometry Mapping Results
NASA Technical Reports Server (NTRS)
Calaway, M. J.; Rodriquez, M. C.; Stansbery, E. K.
2007-01-01
The Genesis concentrator was custom designed to focus solar wind ions primarily for terrestrial isotopic analysis of O-17/O-16 and O-18/O-16 to +/-1%, N-15/N-14 to +/-1%, and secondarily to conduct elemental and isotopic analysis of Li, Be, and B. The circular 6.2 cm diameter concentrator target holder was comprised of four quadrants of highly pure semiconductor materials that included one amorphous diamond-like carbon, one C-13 diamond, and two silicon carbide (SiC). The amorphous diamond-like carbon quadrant was fractured upon impact at Utah Test and Training Range (UTTR), but the remaining three quadrants survived fully intact and all four quadrants hold an important collection of solar wind. The quadrants were removed from the target holder at NASA Johnso n Space Center Genesis Curation Laboratory in April 2005, and have been housed in stainless steel containers under continual nitrogen purge since time of disintegration. In preparation for allocation of a silicon carbide target for oxygen isotope analyses at UCLA, the two SiC targets were photographed for preliminary inspection of macro particle contamination from the hard non-nominal landing as well as characterized by spectroscopic ellipsometry to evaluate thin film contamination. This report is focused on Genesis SiC target sample number 60003.
Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Palmeri, Matteo; Gianardi, Desirée; Bianchini, Matteo; Moglia, Andrea; Ferrari, Vincenzo; Caprili, Giovanni; D'Isidoro, Cristiano; Melfi, Franca; Di Candio, Giulio; Mosca, Franco
2017-08-01
The da Vinci Xi has been developed to overcome some of the limitations of the previous platform, thereby increasing the acceptance of its use in robotic multiorgan surgery. Between January 2015 and October 2015, 10 patients with synchronous tumors of the colorectum and others abdominal organs underwent robotic combined resections with the da Vinci Xi. Trocar positions respected the Universal Port Placement Guidelines provided by Intuitive Surgical for "left lower quadrant," with trocars centered on the umbilical area, or shifted 2 to 3 cm to the right or to the left, depending on the type of combined surgical procedure. All procedures were completed with the full robotic technique. Simultaneous procedures in same quadrant or left quadrant and pelvis, or left/right and upper, were performed with a single docking/single targeting approach; in cases of left/right quadrant or right quadrant/pelvis, we performed a dual-targeting operation. No external collisions or problems related to trocar positions were noted. No patient experienced postoperative surgical complications and the mean hospital stay was 6 days. The high success rate of full robotic colorectal resection combined with other surgical interventions for synchronous tumors, suggest the efficacy of the da Vinci Xi in this setting.
Retinal oxygen saturation in Chinese adolescents.
Liu, Xue; Wang, Shuang; Liu, Yi; Liu, Li Juan; Lv, Yan Yun; Tang, Ping; Jonas, Jost B; Xu, Liang
2017-02-01
To study the retinal oxygen saturation in normal eyes of Chinese adolescents. Performing retinal oximetry with the Oxymap T1 Retinal Oximeter in healthy children and adolescents (aged 5-18 years old), we measured the arterial (SaO 2 ) and venular (SvO 2 ) oxygen saturation and the arteriovenous difference in oxygen saturation (Sa-vO 2 ). The study included 122 individuals with a mean age of 13.0 ± 2.9 years (range: 5-18 years) and a mean refractive error of -3.25 ± 2.49 dioptres (range:-8.88 to +3.13 dioptres). Mean SaO 2 , SvO 2 and Sa-vO 2 was 85.5 ± 7.1%, 48.2 ± 5.5% and 37.3 ± 6.5%, respectively. Mean SaO 2 was significantly (p < 0.001) the lowest in the inferotemporal quadrant (79.1 ± 9.0%), followed by the superotemporal quadrant (83.4 ± 9.7%), the inferonasal quadrant (90.4 ± 10.6%) and the superonasal quadrant (93.4 ± 10.8%). In a similar manner, the values of the SvO 2 were the lowest (p < 0.001) in the inferotemporal quadrant (42.1 ± 8.3%), followed by the superotemporal quadrant (47.8 ± 7.2%), the inferonasal quadrant (52.3 ± 8.4%) and the superonasal quadrant (55.1 ± 7.6%). Arteriovenous difference in oxygen saturation (Sa-vO 2 ) did not differ significantly (all p > 0.05) between the fundus quadrants. In multiple linear regression analysis, SaO 2 increased (regression coefficient r 2 = 0.28) with older age (standardized regression coefficient β: 0.23; p = 0.01) and more myopic refractive error (β: -0.39; p < 0.001). Higher SvO 2 was significantly correlated with more myopic refractive error (β: -0.46; p < 0.001; r 2 = 0.20), while Sa-vO 2 increased significantly only with older age in the multivariate analysis (β: 0.26; p = 0.01; r 2 = 0.07). Our study provides normative data for Chinese children and adolescents who showed lower values than adults for SaO 2 and SvO 2 . SaO 2 increased with older age and higher myopic refractive error, SvO 2 increased with higher myopic refractive error, and Sa-vO 2 increased with older age. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Effects of low-intensity laser therapy on the rate of orthodontic tooth movement: A clinical trial
Kansal, Ankur; Kittur, Nandan; Kumbhojkar, Vinayak; Keluskar, Kanhoba Mahabaleshwar; Dahiya, Parveen
2014-01-01
Background: Low-intensity laser therapy (LILT) can be utilized for different treatments in the field of orthodontics and dentofacial orthopedics. The aim of the present study was to evaluate the efficacy of LILT on (1) the rate of canine movement during canine retraction phase and (2) evaluate the radiographic changes occurring during LILT around the irradiated area. Materials and Methods: A total of 10 patients of both genders were included for this study. One quadrant of the upper arch was considered control group (CG) and received mechanical activation of the canine teeth with 150 g. The opposite quadrant received the same mechanical activation and was also irradiated with a diode emitting light (gallium-arsenide laser) at 904 nm, for 10 s at 12 mW, at 4.2 J/cm2. Laser application was done on 1st day, 3rd, 7th, 14th, 21th, 28th, 35th, 42nd, 49th, 56th day respectively during the canine retraction phase. Distance was measured on 1st day, 35th day and 63rd day and appliance activation was done on 1st and 35th day. Results were analyzed using t-test with the significance level set at P < 0.01. Results: Mean value obtained from 1st to 63rd day was 3.30 ± 2.36 mm for CG and 3.53 ± 2.30 mm for laser group (LG). Conclusion: There was no statistically significant difference in the rate of tooth movement during canine retraction between the LG and the CG. There was no evidence of any pathologic changes in the radiograph following LILT. PMID:25225562
A study of lip print pattern in Goan dental students - A digital approach.
Prabhu, Rachana V; Dinkar, Ajit; Prabhu, Vishnudas
2012-10-01
To find the incidence of different types of lip patterns, the dominant pattern, quadrant wise, amongst the Goan population. To assess, the quadrant wise differences in lip patterns among males and females and to report new lip print pattern in Goan population. Lip prints of 100 students studying in Goa Dental College & Hospital were taken using 14 mm wide and 50 mm long Scotch tape without any distortion. These prints were then scanned (256 gray shades at a resolution of 300 dpi.) for the digital analysis. Using various applications of Adobe Photoshop 7 software an attempt was made to trace each and every line. K. Suzuki and Y. Tsuchihashi's classification was followed to define the patterns of the grooves. The current study has found the most predominant pattern in Quadrant I to be Type V (580 lines; 52.39%) followed in order by Type I' (196 lines; 17.70%), Type I (166 lines; 14.99%), Type II (166 lines; 10.47%), Type IV (40 lines; 3.61%), Type III (9 lines; 0.81%). In Quadrant II of this study the most predominant pattern recorded was Type V (589 lines; 50.47%) followed in order by Type I' (209 lines; 17.90%), Type I (204 lines; 17.48%), Type II (130 lines; 11.13%), Type IV (34 lines; 2.91%), Type III (1 line; 0.08%). In Quadrant III of this study the most predominant pattern recorded was again Type V (484 lines; 52.09%) followed in order by Type I' (174 lines; 18.72%), Type I (155 lines; 16.68%), Type II (102 lines; 10.97%), Type IV (9 lines; 0.96%), Type III (5 lines; 0.53%). In Quadrant IV of this study the most predominant pattern recorded was Type V (543 lines; 58.19%) followed in order by Type I (151 lines; 16.18%), Type I' (138 lines; 14.79%), Type II (85 lines; 9.11%), Type III (9 lines; 0.96%), Type IV (7 line; 0.75%). In all four Quadrants the most predominant pattern found in males and females was Type V. The present study recorded the following types of type V patterns for the first time; Trifurcations, Bridge or 'H' pattern, Horizontal Lines, Cartwheel, Pineapple Skin and Multiple Branching Appearance. The digital method of analyzing the Lip Print images using Adobe Photoshop 7 software serves as a convenient method that provides better visualization and ease in identification and recording of the Lip Print pattern. Predominant pattern in all four quadrants was Type V followed by the linear pattern i.e. Type I' in quadrants I, II, and III and Type I in quadrant IV in the studied population. Distribution of pattern is not affected by the sex. Although type V is the most predominant pattern found in Goan population, the sub-classification of this type defines the more defined term and aids in accuracy of the classification. Copyright © 2012. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
Lamb, William G.
1983-01-01
Instructions for constructing cross staffs and quadrants are provided. Astronomy teaching methods using the two devices are discussed. These include locating common constellations with the cross staff and following a star (or moon, sun, or planets) by reading the altitude and azimuth with the quadrant. (JN)
Northeastern Quadrant of the Caloris Basin
2000-01-14
This image, from NASA Mariner 10 spacecraft which launched in 1974, is of the northeastern quadrant of the Caloris basin and shows the smooth hills and domes between the inner and outer scarps and the well-developed radial system east of the outer scarp
Kim, Ho Soong; Yang, Heon; Lee, Tae Heon; Lee, Kyung Heon
2016-06-01
To determine the diagnostic value of the ganglion cell-inner plexiform layer (GCIPL) thickness in glaucomatous eyes with superior or inferior visual hemifield defects. Eighty-five patients with glaucoma (42 isolated superior hemifield defects and 43 isolated inferior hemifield defects) and 46 normal subjects were enrolled. All patients underwent Cirrus high-definition optical coherence tomography and standard automated perimetry. The area under the receiver operating characteristic curve (AUC) was calculated to determine the diagnostic ability of the GCIPL and peripapillary retinal nerve fiber layer (pRNFL). In the superior hemifield defect glaucoma group, the best parameters for discriminating normal eyes from glaucomatous eyes were the inferotemporal GCIPL thickness (0.942), inferior quadrant RNFL thickness (0.974), and 7 o'clock sector RNFL thickness (0.999). For diagnosing inferior hemifield defect glaucoma, the AUCs of all GCIPL parameters (0.331 to 0.702) were significantly lower than that of the superior quadrant RNFL thickness (0.866, P<0.05). The diagnostic ability of GCIPL parameters was similar to that of the pRNFL parameters in superior hemifield defect glaucoma. However, the diagnostic performance of the GCIPL parameters was significantly inferior to those of the pRNFL parameters in eyes with inferior hemifield defect glaucoma.
Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns
Esquivel-Upshaw, J.F.; Kim, M.J.; Hsu, S.M.; Abdulhameed, N.; Jenkins, R.; Neal, D.; Ren, F.; Clark, A.E.
2018-01-01
Objectives To test the hypothesis that there is no difference in the in vivo maximum wear of enamel opposing monolithic zirconia crowns, enamel opposing porcelain fused to metal crowns and enamel opposing enamel. Methods Thirty patients needing single crowns were randomized to receive either a monolithic zirconia or metal-ceramic crown. Two non-restored opposing teeth in the same quadrants were identified to serve as enamel controls. After cementation, quadrants were scanned for baseline data. Polyvinylsiloxane impressions were obtained and poured in white stone. Patients were recalled at six-months and one-year for re-impression. Stone models were scanned using a tabletop laserscanner to determine maximum wear. Statistical analysis was performed using Mann-Whitney U to determine any significant differences between the wear of enamel against zirconia and metal-ceramic crowns. Results Sixteen zirconia and 14 metal-ceramic crowns were delivered. There were no statistical differences in mean wear of crown types (p = 0.165); enamel antagonists (p = 0.235) and enamel controls (p = 0.843) after one year. Conclusion Monolithic zirconia exhibited comparable wear of enamel compared with metal-ceramic crowns and control enamel after one year. Significance This study is clinically significant because the use of polished monolithic zirconia demonstrated comparable wear of opposing enamel to metal-ceramic and enamel antagonists. PMID:29042241
Preus, Hans Ragnar; Koldsland, Odd Carsten; Aass, Anne Merete; Sandvik, Leiv; Hansen, Bjørn Frode
2013-11-01
Studies have reported commercially available essential oils with convincing plaque and gingivitis preventing properties. However, no tests have compared these essential oils, i.e. Listerine(®), against their true vehicle controls. To compare the plaque and gingivitis inhibiting effect of a commercially-available essential oil (Listerine(®) Total Care) to a negative (22% hydro-alcohol solution) and a positive (0.2% chlorhexidine (CHX)) control in an experimental gingivitis model. In three groups of 15 healthy volunteers, experimental gingivitis was induced and monitored over 21 days, simultaneously treated with Listerine(®) Total Care (test), 22% hydro-alcohol solution (negative control) and 0.2% chlorhexidine solution (positive control), respectively. The upper right quadrant of each individual received mouthwash only, whereas the upper left quadrant was subject to both rinses and mechanical oral hygiene. Plaque, gingivitis and side-effects were assessed at day 7, 14 and 21. After 21 days, the chlorhexidine group showed significantly lower average plaque and gingivitis scores than the Listerine(®) and alcohol groups, whereas there was little difference between the two latter. Listerine(®) Total Care had no statistically significant effect on plaque formation as compared to its vehicle control.
Nyman, S; Westfelt, E; Sarhed, G; Karring, T
1988-08-01
This clinical trial was undertaken to examine whether root debridement in the treatment of periodontal disease must include the removal of the exposed cementum in order to achieve periodontal health. The study included 11 adult patients with moderate to advanced periodontal disease. In a split-mouth design, the dentition of each patient was by random selection divided into test- and control quadrants comprising the incisors, canines and premolars. Following a baseline examination, all patients were given a case presentation and a detailed instruction in self-performed oral hygiene measures. The patients were then subjected to periodontal surgery. Following reverse bevel incisions, buccal and lingual mucoperiosteal flaps were elevated and all granulation tissue was removed. In 2 jaw quadrants (control quadrants) in each patient, the denuded root surfaces were carefully scaled and planed in order to remove soft and hard deposits as well as all cementum, using hand instruments and flame-formed diamond stones. In the contralateral quadrants (test quadrants) the roots were not scaled and planed but soft microbial deposits were removed by polishing the root surfaces with the but soft microbial deposits were removed by polishing the root surfaces with the use of rubber cups, interdental rubber tips and a polishing paste. Calculus in the test quadrants was removed by the use of a curette, but precaution was taken to avoid the removal of cementum. The flaps were repositioned to their original level and sutured. The patients were following active treatment enrolled in a supervised maintenance care program including "professional tooth cleaning" once every 2 weeks for a 3-month period.(ABSTRACT TRUNCATED AT 250 WORDS)
Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2010-06-01
To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.
Kelbauskiene, Solveiga; Baseviciene, Nomeda; Goharkhay, Kawe; Moritz, Andreas; Machiulskiene, Vita
2011-07-01
In 30 patients with periodontitis, a total of 278 teeth exhibiting bleeding on probing, subgingival calculus, and a probing depth between 3-6 mm were examined. For each participant, two treatment types were alternatively applied on the contralateral quadrants: scaling and root planing (SRP) as control, and SRP followed by Er,Cr:YSGG laser application (SRP+laser), as a test method. Five clinical parameters: plaque level, bleeding on probing, probing depth, gingival recession and clinical attachment level were examined at baseline and at 2, 3, 6, 12 months after treatment. Of the total of 1,668 sites examined in all patients, 1,088 sites were found with a probing depth of 3-6 mm. In these sites, differences in clinical parameters between SRP and SRP+laser-treated quadrants were analyzed, assuming the level of p < 0.05 as significant. After 2 months from baseline, the mean probing depth reduction and the clinical attachment level gain were significantly greater in SRP+laser than in SRP quadrants, and remained so throughout the study (p < 0.001). A marked reduction of the bleeding scores occurred in all examined sites, irrespective of the treatment method. However, after 12 months, significantly less teeth exhibited bleeding on probing in SRP+laser quadrants than in SRP quadrants (p < 0.001). The mean plaque and gingival recession levels did not differ between the SRP and SRP+laser quadrants neither before nor after the treatment. The periodontal procedures either using Er,Cr:YSGG laser after SRP or SRP alone, lead to significant improvements in all clinical parameters investigated. However, laser application, as an adjunct to SRP, appeared to be more advantageous.
Toth, Robert J.; Shih, Natalie; Tomaszewski, John E.; Feldman, Michael D.; Kutter, Oliver; Yu, Daphne N.; Paulus, John C.; Paladini, Ginaluca; Madabhushi, Anant
2014-01-01
Context: Co-registration of ex-vivo histologic images with pre-operative imaging (e.g., magnetic resonance imaging [MRI]) can be used to align and map disease extent, and to identify quantitative imaging signatures. However, ex-vivo histology images are frequently sectioned into quarters prior to imaging. Aims: This work presents Histostitcher™, a software system designed to create a pseudo whole mount histology section (WMHS) from a stitching of four individual histology quadrant images. Materials and Methods: Histostitcher™ uses user-identified fiducials on the boundary of two quadrants to stitch such quadrants. An original prototype of Histostitcher™ was designed using the Matlab programming languages. However, clinical use was limited due to slow performance, computer memory constraints and an inefficient workflow. The latest version was created using the extensible imaging platform (XIP™) architecture in the C++ programming language. A fast, graphics processor unit renderer was designed to intelligently cache the visible parts of the histology quadrants and the workflow was significantly improved to allow modifying existing fiducials, fast transformations of the quadrants and saving/loading sessions. Results: The new stitching platform yielded significantly more efficient workflow and reconstruction than the previous prototype. It was tested on a traditional desktop computer, a Windows 8 Surface Pro table device and a 27 inch multi-touch display, with little performance difference between the different devices. Conclusions: Histostitcher™ is a fast, efficient framework for reconstructing pseudo WMHS from individually imaged quadrants. The highly modular XIP™ framework was used to develop an intuitive interface and future work will entail mapping the disease extent from the pseudo WMHS onto pre-operative MRI. PMID:24843820
Tumour location within the breast: Does tumour site have prognostic ability?
Rummel, Seth; Hueman, Matthew T; Costantino, Nick; Shriver, Craig D; Ellsworth, Rachel E
2015-01-01
Tumour location within the breast varies with the highest frequency in the upper outer quadrant (UOQ) and lowest frequency in the lower inner quadrant (LIQ). Whether tumour location is prognostic is unclear. To determine whether tumour location is prognostic, associations between tumour site and clinicopathological characteristics were evaluated. All patients enrolled in the Clinical Breast Care Project whose tumour site-UOQ, upper inner quadrant (UIQ), central, LIQ, lower outer quadrant (LOQ)-was determined by a single, dedicated breast pathologist were included in this study. Patients with multicentric disease (n = 122) or tumours spanning multiple quadrants (n = 381) were excluded from further analysis. Clinicopathological characteristics were analysed using chi-square tests for univariate analysis with multivariate analysis performed using principal components analysis (PCA) and multiple logistic regression. Significance was defined as P < 0.05. Of the 980 patients with defined tumour location, 30 had bilateral disease. Tumour location in the UOQ (51.5%) was significantly higher than in the UIQ (15.6%), LOQ (14.2%), central (10.6%), or LIQ (8.1%). Tumours in the central quadrant were significantly more likely to have higher tumour stage (P = 0.003) and size (P < 0.001), metastatic lymph nodes (P < 0.001), and mortality (P = 0.011). After multivariate analysis, only tumour size and lymph node status remained significantly associated with survival. Evaluation of tumour location as a prognostic factor revealed that although tumours in the central region are associated with less favourable outcome, these associations are not independent of location but rather driven by larger tumour size. Tumours in the central region are more difficult to detect mammographically, resulting in larger tumour size at diagnosis and thus less favourable prognosis. Together, these data demonstrate that tumour location is not an independent prognostic factor.
Teaching Basic Field Skills Using Screen-Based Virtual Reality Landscapes
NASA Astrophysics Data System (ADS)
Houghton, J.; Robinson, A.; Gordon, C.; Lloyd, G. E. E.; Morgan, D. J.
2016-12-01
We are using screen-based virtual reality landscapes, created using the Unity 3D game engine, to augment the training geoscience students receive in preparing for fieldwork. Students explore these landscapes as they would real ones, interacting with virtual outcrops to collect data, determine location, and map the geology. Skills for conducting field geological surveys - collecting, plotting and interpreting data; time management and decision making - are introduced interactively and intuitively. As with real landscapes, the virtual landscapes are open-ended terrains with embedded data. This means the game does not structure student interaction with the information as it is through experience the student learns the best methods to work successfully and efficiently. These virtual landscapes are not replacements for geological fieldwork rather virtual spaces between classroom and field in which to train and reinforcement essential skills. Importantly, these virtual landscapes offer accessible parallel provision for students unable to visit, or fully partake in visiting, the field. The project has received positive feedback from both staff and students. Results show students find it easier to focus on learning these basic field skills in a classroom, rather than field setting, and make the same mistakes as when learning in the field, validating the realistic nature of the virtual experience and providing opportunity to learn from these mistakes. The approach also saves time, and therefore resources, in the field as basic skills are already embedded. 70% of students report increased confidence with how to map boundaries and 80% have found the virtual training a useful experience. We are also developing landscapes based on real places with 3D photogrammetric outcrops, and a virtual urban landscape in which Engineering Geology students can conduct a site investigation. This project is a collaboration between the University of Leeds and Leeds College of Art, UK, and all our virtual landscapes are freely available online at www.see.leeds.ac.uk/virtual-landscapes/.
High-Resolution Large-Field-of-View Three-Dimensional Hologram Display System and Method Thereof
NASA Technical Reports Server (NTRS)
Chao, Tien-Hsin (Inventor); Mintz, Frederick W. (Inventor); Tsou, Peter (Inventor); Bryant, Nevin A. (Inventor)
2001-01-01
A real-time, dynamic, free space-virtual reality, 3-D image display system is enabled by using a unique form of Aerogel as the primary display media. A preferred embodiment of this system comprises a 3-D mosaic topographic map which is displayed by fusing four projected hologram images. In this embodiment, four holographic images are projected from four separate holograms. Each holographic image subtends a quadrant of the 4(pi) solid angle. By fusing these four holographic images, a static 3-D image such as a featured terrain map would be visible for 360 deg in the horizontal plane and 180 deg in the vertical plane. An input, either acquired by 3-D image sensor or generated by computer animation, is first converted into a 2-D computer generated hologram (CGH). This CGH is then downloaded into large liquid crystal (LC) panel. A laser projector illuminates the CGH-filled LC panel and generates and displays a real 3-D image in the Aerogel matrix.
The ability of ewes with lambs to learn a virtual fencing system.
Brunberg, E I; Bergslid, I K; Bøe, K E; Sørheim, K M
2017-11-01
The Nofence technology is a GPS-based virtual fencing system designed to keep sheep within predefined borders, without using physical fences. Sheep wearing a Nofence collar receive a sound signal when crossing the virtual border and a weak electric shock if continuing to walk out from the virtual enclosure. Two experiments testing the functionality of the Nofence system and a new learning protocol is described. In Experiment 1, nine ewes with their lambs were divided into groups of three and placed in an experimental enclosure with one Nofence border. During 2 days, there was a physical fence outside the border, during Day 3 the physical fence was removed and on Day 4, the border was moved to the other end of the enclosure. The sheep received between 6 and 20 shocks with an average of 10.9±2.0 (mean±SE) per ewe during all 4 days. The number of shocks decreased from 4.38±0.63 on Day 3 (when the physical fence was removed) to 1.5±0.71 on Day 4 (when the border was moved). The ewes spent on average 3%, 6%, 46% and 9% of their time outside the border on Days 1, 2, 3 and 4, respectively. In Experiment 2, 32 ewes, with and without lambs, were divided into groups of eight and placed in an experimental enclosure. On Day 1, the enclosure was fenced with three physical fences and one virtual border, which was then increased to two virtual borders on Day 2. To continue to Day 3, when there was supposed to be three virtual borders on the enclosure, at least 50% of the ewes in a group should have received a maximum of four shocks on Day 2. None of the groups reached this learning criterion and the experiment ended after Day 2. The sheep received 4.1±0.32 shocks on Day 1 and 4.7±0.28 shocks on Day 2. In total, 71% of the ewes received the maximum number of five shocks on Day 1 and 77% on Day 2. The individual ewes spent between 0% and 69.5% of Day 1 in the exclusion zone and between 0% and 64% on Day 2. In conclusion, it is too challenging to ensure an efficient learning and hence, animal welfare cannot be secured. There were technical challenges with the collars that may have affected the results. The Nofence prototype was unable to keep the sheep within the intended borders, and thus cannot replace physical fencing for sheep.
Tsuda, Kenji; Sudo, Kazuaki; Goto, Goro; Takai, Makiko; Itokawa, Tatsuo; Isshiki, Takahiro; Takei, Naoko; Tanimoto, Tetsuya; Komatsu, Tsunehiko
2016-01-01
Adherence to rehabilitation exercise is much lower in patients with hematologic malignancies (22.5-45.8%) than in patients with solid tumors (60-85%) due to the administration of more intensive chemotherapeutic regimens in the former. Virtual reality exercise can be performed even in a biological clean room and it may improve the adherence rates in elderly patients with hematologic malignancies. Thus, in this pilot study, we aimed to investigate the feasibility and safety of virtual reality exercise intervention using Nintendo Wii Fit in patients with hematologic malignancies receiving chemotherapy. In this feasibility study, 16 hospitalized patients with hematologic malignancies aged ≥60 years performed virtual reality exercise for 20 minutes using the Nintendo Wii Fit once a day, five times a week, from the start of chemotherapy until hospital discharge. The adherence rate, safety, and physical and psychological performances were assessed. The adherence rate for all 16 patients was 66.5%. Nine patients completed the virtual reality exercise intervention with 88 sessions, and the adherence rate was 62.0%. No intervention-related adverse effects >Grade 2, according to National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0, were observed. We noted maintenance of the physical performance (e.g., Barthel index, handgrip strength, knee extension strength, one-leg standing time, and the scores of timed up and go test and Instrumental Activities of Daily Living) and psychosocial performance (e.g., score of hospital anxiety and depression scale). Virtual reality exercise using the Wii Fit may be feasible, safe and efficacious, as demonstrated in our preliminary results, for patients with hematologic malignancies receiving chemotherapy.
Chandra, Rampalli Viswa; Prabhuji, M L Venkatesh; Roopa, D Adinarayana; Ravirajan, Sandhya; Kishore, Hadal C
2007-01-01
The aim of the present study was to compare the effect of systemically administered lycopene (LycoRed) as a monotherapy and as an adjunct to scaling and root planing in gingivitis patients. Twenty systemically healthy patients showing clinical signs of gingivitis were involved in a randomised, double-blind, parallel, split-mouth study. The subjects were randomly distributed between the two treatment groups: experimental group (n = 10), 8 mg lycopene/day for 2 weeks; and controls (n = 10), placebo for 2 weeks. Quadrant allocation within each group was randomised with two quadrants treated with oral prophylaxis (OP) and two quadrants not receiving any form of treatment (non-OP). Bleeding index (SBI) and non-invasive measures of plaque (PI) and gingivitis (GI) were assessed at baseline, 1 and 2 weeks. Salivary uric acid levels were also measured. All the treatment groups demonstrated statistically significant reductions in the GI, SBI and PI. Treatment with OP-lycopene resulted in a statistically significant decrease in GI when compared with OP-placebo (p < 0.05) and non-OP-placebo (p < 0.01). Treatment with non-OP-lycopene resulted in a statistically significant decrease in GI when compared with non-OP-placebo (p < 0.01). The OP-lycopene group showed a statistically significant reduction in SBI values when compared with the non-OP-lycopene group (p < 0.05) and the non-OP-placebo group (p < 0.001). There was a strong negative correlation between the salivary uric acid levels and the percentage reduction in GI at 1 and 2 weeks in the OP-lycopene group (r = -0.852 and -0.802 respectively) and in the non-OP-lycopene group (r = -0.640 and -0.580 respectively). The results presented in this study suggest that lycopene shows great promise as a treatment modality in gingivitis. The possibility of obtaining an additive effect by combining routine oral prophylaxis with lycopene is also an exciting possibility, which deserves further study.
Crushing virtual cigarettes reduces tobacco addiction and treatment discontinuation.
Girard, Benoit; Turcotte, Vincent; Bouchard, Stéphane; Girard, Bruno
2009-10-01
Pilot studies revealed promising results regarding crushing virtual cigarettes to reduce tobacco addiction. In this study, 91 regular smokers were randomly assigned to two treatment conditions that differ only by the action performed in the virtual environment: crushing virtual cigarettes or grasping virtual balls. All participants also received minimal psychosocial support from nurses during each of 12 visits to the clinic. An affordable virtual reality system was used (eMagin HMD) with a virtual environment created by modifying a 3D game. Results revealed that crushing virtual cigarettes during 4 weekly sessions led to a statistically significant reduction in nicotine addiction (assessed with the Fagerström test), abstinence rate (confirmed with exhaled carbon monoxide), and drop-out rate from the 12-week psychosocial minimal-support treatment program. Increased retention in the program is discussed as a potential explanation for treatment success, and hypotheses are raised about self-efficacy, motivation, and learning.
DOT National Transportation Integrated Search
2012-12-01
The Wavetronix Matrix Radar was adapted for use at four-quadrant gate railroad crossings for the purpose of influencing exit gate behavior upon the detection of vehicles, as an alternative to buried inductive loops. Two radar devices were utilized, o...
Jahnke, S M; Redaelli, L R; Diefenbach, L M G; Efrom, C F
2008-11-01
Many species of microhymenopterous parasitoids have been registered on Phyllocnistis citrella, the citrus leafminer. The present study aimed to identify the spatial distribution pattern of the native and introduced parasitoids of P. citrella in two citrus orchards in Montenegro, RS. The new shoots from 24 randomly selected trees in each orchard were inspected at the bottom (0-1.5 m) and top (1.5-2.5 m) stratum and had their position relative to the quadrants (North, South, East and West) registered at every 15 days from July/2002 to June/2003. The leaves with pupae were collected and kept isolated until the emergence of parasitoids or of the leaf miner; so, the sampling was biased towards parasitoids that emerge in the host pupal phase. The horizontal spatial distribution was evaluated testing the fitness of data to the Poisson and negative binomial distributions. In Montenegrina, there was no significant difference in the number of parasitoids and in the mean number of pupae found in the top and bottom strata (chi2 = 0.66; df = 1; P > 0.05) (chi2 = 0.27; df =1; P > 0.05), respectively. In relation to the quadrants, the highest average numbers of the leafminer pupae and of parasitoids were registered at the East quadrant (chi2 = 11.81; df = 3; P < 0.05), (chi2 = 10.36; df = 3; P < 0.05). In the Murcott orchard, a higher number of parasitoids was found at the top stratum (63.5%) (chi2 = 7.24; df =1 P < 0.05), the same occurring with the average number of P. citrella pupae (62.9%) (chi2 = 6.66; df = 1; P < 0.05). The highest number of parasitoids and of miners was registered at the North quadrant (chi2 = 19. 29; df = 3; P < 0.05), (chi2 = 4.39; df = 3; P < 0.05). In both orchards, there was no difference between the numbers of shoots either relative to the strata as well as to the quadrants. As the number of shoots did not varied much relative to the quadrants, it is possible that the higher number of miners and parasitoids in the East and West quadrants would be influenced by the higher solar exposure of these quadrants. The data of the horizontal spatial distribution of the parasitism fit to the negative binomial distribution in all sampling occasions, indicating an aggregated pattern.
Where Does the Transplanted Fat is Located in the Gluteal Region? Research Letter.
Ramos-Gallardo, Guillermo; Medina-Zamora, Pablo; Cardenas-Camarena, Lázaro; Orozco-Rentería, David; Duran-Vega, Héctor; Mota-Fonseca, Eduardo
2017-12-29
Liposuction is one of the most popular plastic surgery procedures. As in any surgery, there are risks and complications, especially when combined with fat injection. Case reports of fat embolism have been reported. A possible explanation is the puncture and tearing of gluteal vessels during the procedure, especially when a deep injection is planned. To identify the places where fat can be located after injection during a fat graft in the gluteus. An experimental study was done in which colorant was injected in four directions using four different quadrants of the gluteus. We Injected 10 cc six times following clock hands until 60 cc were injected, and the cutaneous flap and the muscles were then elevated. Our main purpose was to describe where the colorant went and if it was in contact with the vessels (superior and inferior gluteal vessels). In total, four gluteus muscles were injected and dissected. Injection in the lower lateral quadrant was mainly into the muscle, and colorant was observed in the hypogastric vessels. The injection in the upper quadrants stayed mainly in the subcutaneous tissue. During surgery, it is important to identify the location of the perforators and to avoid a deep injection, especially from the lower lateral quadrant to the superior medial quadrant (Q4 to Q1), as the probability of puncturing and injecting fat into the main vessels from this direction is higher.
Reducing Negative Effects from Virtual Environments: Implications for Just-In-Time Training
2003-02-01
ability to perform mission- critical tasks following VE exposure. For instance, a group of side effects collectively known as cybersickness can be...detracting, such as visual motor coordination and balance disturbances. Cybersickness occurs in approximately 80-95% of individuals receiving virtual
Virtual plane-wave imaging via Marchenko redatuming
NASA Astrophysics Data System (ADS)
Meles, Giovanni Angelo; Wapenaar, Kees; Thorbecke, Jan
2018-04-01
Marchenko redatuming is a novel scheme used to retrieve up- and down-going Green's functions in an unknown medium. Marchenko equations are based on reciprocity theorems and are derived on the assumption of the existence of functions exhibiting space-time focusing properties once injected in the subsurface. In contrast to interferometry but similarly to standard migration methods, Marchenko redatuming only requires an estimate of the direct wave from the virtual source (or to the virtual receiver), illumination from only one side of the medium, and no physical sources (or receivers) inside the medium. In this contribution we consider a different time-focusing condition within the frame of Marchenko redatuming that leads to the retrieval of virtual plane-wave responses. As a result, it allows multiple-free imaging using only a one-dimensional sampling of the targeted model at a fraction of the computational cost of standard Marchenko schemes. The potential of the new method is demonstrated on 2D synthetic models.
Mechanism of Action for Obtaining Job Offers With Virtual Reality Job Interview Training.
Smith, Matthew J; Smith, Justin D; Fleming, Michael F; Jordan, Neil; Brown, C Hendricks; Humm, Laura; Olsen, Dale; Bell, Morris D
2017-07-01
Four randomized controlled trials revealed that virtual-reality job interview training (VR-JIT) improved interviewing skills and the odds of obtaining a job offer among trainees with severe mental illness or autism spectrum disorder. This study assessed whether postintervention interviewing skills mediated the relationship between completion of virtual interviews and receiving job offers by six-month follow-up. VR-JIT trainees (N=79) completed pre- and posttest mock interviews and a brief survey approximately six months later to assess whether they received a job offer. As hypothesized, analyses indicated that the number of completed virtual interviews predicted greater posttest interviewing skills (β=.20, 95% posterior credible interval [PCI]=.08-.33), which in turn predicted trainees' obtaining a job offer (β=.28, 95% PCI=.01-.53). VR-JIT may provide a mechanism of action that helps trainees with various psychiatric diagnoses obtain job offers in the community. Future research can evaluate the community-based effectiveness of this novel intervention.
The effect of virtual reality training on unilateral spatial neglect in stroke patients.
Kim, Yong Mi; Chun, Min Ho; Yun, Gi Jeong; Song, Young Jin; Young, Han Eun
2011-06-01
To investigate the effect of virtual reality training on unilateral spatial neglect in stroke patients. Twenty-four stroke patients (14 males and 10 females, mean age=64.7) who had unilateral spatial neglect as a result of right hemisphere stroke were recruited. All patients were randomly assigned to either the virtual reality (VR) group (n=12) or the control group (n=12). The VR group received VR training, which stimulated the left side of their bodies. The control group received conventional neglect therapy such as visual scanning training. Both groups received therapy for 30 minutes a day, five days per week for three weeks. Outcome measurements included star cancellation test, line bisection test, Catherine Bergego scale (CBS), and the Korean version of modified Barthel index (K-MBI). These measurements were taken before and after treatment. There were no significant differences in the baseline characteristics and initial values between the two groups. The changes in star cancellation test results and CBS in the VR group were significantly higher than those of the control group after treatment. The changes in line bisection test score and the K-MBI in the VR group were not statistically significant. This study suggests that virtual reality training may be a beneficial therapeutic technique on unilateral spatial neglect in stroke patients.
Cultural-Historical Activity Theory/Design-Based Research in Pasteur's Quadrant
ERIC Educational Resources Information Center
Greeno, James G.
2016-01-01
About two decades ago, Donald Stokes published "Pasteur's Quadrant" (Stokes, 1997). Stokes proposed that the motivations of different research projects can be understood as a two-dimensional system, with higher or lower concern for improving technology and practice on one dimension and higher or lower concern for improving fundamental…
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Reverse gear. 230.89 Section 230.89 Transportation... Reversing Gear § 230.89 Reverse gear. (a) General provisions. Reverse gear, reverse levers, and quadrants... quadrant. Proper counterbalance shall be provided for the valve gear. (b) Air-operated power reverse gear...
"Failure" Irrelevant: Virtual Schools and Accountability-Immunity
ERIC Educational Resources Information Center
Nespor, Jan; Voithofer, Rick
2016-01-01
Background: Virtual schools--free, state-funded, credit-awarding elementary and secondary schools offering curricula and programs exclusively online--are a rapidly expanding sector of U.S. education. Some of the largest of these schools have low graduation rates and receive "failing" rankings on state accountability metrics. They…
Desktop Virtualization in Action: Simplicity Is Power
ERIC Educational Resources Information Center
Fennell, Dustin
2010-01-01
Discover how your institution can better manage and increase access to instructional applications and desktops while providing a blended learning environment. Receive practical insight into how academic computing virtualization can be leveraged to enhance education at your institution while lowering Total Cost of Ownership (TCO) and reducing the…
Gender differences in landmark learning for virtual navigation: the role of distance to a goal.
Chamizo, V D; Artigas, A A; Sansa, J; Banterla, F
2011-09-01
We used a new virtual program in two experiments to prepare subjects to perform the Morris water task (www.nesplora.com). The subjects were Psychology students; they were trained to locate a safe platform amidst the presence of four pinpoint landmarks spaced around the edge of the pool (i.e., two landmarks relatively near the platform and two landmarks relatively distant away from it). At the end of the training phase, we administered one test trial without the platform and recorded the amount of time that the students had spent in the platform quadrant. In Experiment 1, we conducted the test trial in the presence of one or two of the distant landmarks. When only one landmark was present during testing, performance fell to chance. However, the men outperformed the women when the two distant landmarks were both present. Experiment 2 replicated the previous results and extended it by showing that no sex differences exist when the searching process is based on the near landmarks. Both the men and the women had similarly good performances when the landmarks were present both individually and together. When present together, an addition effect was found. Far landmark tests favor configural learning processes, whereas near landmark tests favor elemental learning. Our findings suggest that other factors in addition to the use of directional cues can underlie the sex differences in the spatial learning process. Thus, we expand upon previous research in the field. Copyright © 2011 Elsevier B.V. All rights reserved.
The "four quadrants" approach to clinical ethics case analysis; an application and review.
Sokol, D K
2008-07-01
In 1982, Jonsen, Siegler and Winslade published Clinical Ethics, in which they described the "four quadrants" approach, a new method of analysing clinical ethics cases. Although the book is now in its 6th edition, a literature search has revealed only one academic paper demonstrating the method at work. This paper is an attempt to start filling this gap. As a way of describing and testing the approach, I apply the four quadrants method to a detailed clinical ethics case. The analysis is interspersed with reflections on the method itself. It is hoped that this experiment will encourage ethicists and clinicians to devote more attention to this neglected approach.
Rouleau, Geneviève; Ramirez-Garcia, Pilar; Bourbonnais, Anne
2015-01-01
Background Persons living with HIV (PLHIV) must adhere optimally to antiretroviral therapy (ART) on a daily basis and for their lifetime to maintain an undetectable viral load, allowing them to preserve their health. Taking advantage of the opportunity that information and communication technologies provide to broaden intervention modalities and intensify clinical follow-up, a virtual nursing intervention consisting of four interactive computer sessions was developed to empower PLHIV to manage their ART and symptoms optimally. Compared with other types of information and communication technologies-assisted interventions such as text messages, HIV Treatment, Virtual Nursing Assistance and Education (VIH-TAVIE) requires a certain degree of active engagement on the part of the user to develop and strengthen the self-management skills to optimize adherence. After the intervention’s impact on ART adherence was measured quantitatively, a qualitative study was undertaken to describe how users experience the intervention. Understanding how PLHIV perceive being assisted asynchronously by a virtual nurse was of particular interest. Objective The objective of the study was to explore and describe how PLHIV experience VIH-TAVIE, that is, receiving customized asynchronous accompaniment via a virtual nurse. Methods A qualitative study was conducted with 26 PLHIV (20 men, 6 women) who received all four VIH-TAVIE sessions. Participants had been diagnosed with HIV 14 years earlier on average and had been on ART for a mean period of 10 years. The sessions lasted 20-30 minutes each and were received two weeks apart. They are hosted by a virtual nurse who engages the user in a self-management skills-learning process for the purpose of treatment adherence. Semistructured interviews were conducted lasting 30-40 minutes to get participants to share their experience of the intervention through personal stories and what they thought and felt during their participation. Data were analyzed using Miles and Huberman’s method, by performing these three steps: (1) data reduction (data coding, summaries); (2) data display (in tables and text form); and (3) recontextualization of results. Results Content analysis yielded five themes regarding how PLHIV experience VIH-TAVIE: (1) exposure to the virtual nursing intervention; (2) virtual nurse humanizes experience of the computer-delivered intervention; (3) learner’s experience of the virtual nursing intervention; (4) perceived benefits following participation in the virtual nursing intervention; and (5) relevance of the virtual nursing intervention in relation to the medication management trajectory. Conclusions Analyzing the participants’ experience revealed they found the intervention’s content and format appropriate. To them, the virtual nurse humanized the experience and helped them acquire new skills for achieving optimal ART adherence. Results seem to underscore the importance of offering the intervention to persons who have more problems with drug intake or who are just beginning ART. PMID:26487327
Côté, José; Rouleau, Geneviève; Ramirez-Garcia, Pilar; Bourbonnais, Anne
2015-10-20
Persons living with HIV (PLHIV) must adhere optimally to antiretroviral therapy (ART) on a daily basis and for their lifetime to maintain an undetectable viral load, allowing them to preserve their health. Taking advantage of the opportunity that information and communication technologies provide to broaden intervention modalities and intensify clinical follow-up, a virtual nursing intervention consisting of four interactive computer sessions was developed to empower PLHIV to manage their ART and symptoms optimally. Compared with other types of information and communication technologies-assisted interventions such as text messages, HIV Treatment, Virtual Nursing Assistance and Education (VIH-TAVIE) requires a certain degree of active engagement on the part of the user to develop and strengthen the self-management skills to optimize adherence. After the intervention's impact on ART adherence was measured quantitatively, a qualitative study was undertaken to describe how users experience the intervention. Understanding how PLHIV perceive being assisted asynchronously by a virtual nurse was of particular interest. The objective of the study was to explore and describe how PLHIV experience VIH-TAVIE, that is, receiving customized asynchronous accompaniment via a virtual nurse. A qualitative study was conducted with 26 PLHIV (20 men, 6 women) who received all four VIH-TAVIE sessions. Participants had been diagnosed with HIV 14 years earlier on average and had been on ART for a mean period of 10 years. The sessions lasted 20-30 minutes each and were received two weeks apart. They are hosted by a virtual nurse who engages the user in a self-management skills-learning process for the purpose of treatment adherence. Semistructured interviews were conducted lasting 30-40 minutes to get participants to share their experience of the intervention through personal stories and what they thought and felt during their participation. Data were analyzed using Miles and Huberman's method, by performing these three steps: (1) data reduction (data coding, summaries); (2) data display (in tables and text form); and (3) recontextualization of results. Content analysis yielded five themes regarding how PLHIV experience VIH-TAVIE: (1) exposure to the virtual nursing intervention; (2) virtual nurse humanizes experience of the computer-delivered intervention; (3) learner's experience of the virtual nursing intervention; (4) perceived benefits following participation in the virtual nursing intervention; and (5) relevance of the virtual nursing intervention in relation to the medication management trajectory. Analyzing the participants' experience revealed they found the intervention's content and format appropriate. To them, the virtual nurse humanized the experience and helped them acquire new skills for achieving optimal ART adherence. Results seem to underscore the importance of offering the intervention to persons who have more problems with drug intake or who are just beginning ART.
Milky Way Kinematics. II. A Uniform Inner Galaxy H I Terminal Velocity Curve
NASA Astrophysics Data System (ADS)
McClure-Griffiths, N. M.; Dickey, John M.
2016-11-01
Using atomic hydrogen (H I) data from the VLA Galactic Plane Survey, we measure the H I terminal velocity as a function of longitude for the first quadrant of the Milky Way. We use these data, together with our previous work on the fourth Galactic quadrant, to produce a densely sampled, uniformly measured, rotation curve of the northern and southern Milky Way between 3 {kpc}\\lt R\\lt 8 {kpc}. We determine a new joint rotation curve fit for the first and fourth quadrants, which is consistent with the fit we published in McClure-Griffiths & Dickey and can be used for estimating kinematic distances interior to the solar circle. Structure in the rotation curves is now exquisitely well defined, showing significant velocity structure on lengths of ˜200 pc, which is much greater than the spatial resolution of the rotation curve. Furthermore, the shape of the rotation curves for the first and fourth quadrants, even after subtraction of a circular rotation fit shows a surprising degree of correlation with a roughly sinusoidal pattern between 4.2\\lt R\\lt 7 kpc.
Giulianotti, Richard; Robertson, Roland
2012-06-01
This paper provides a sociological model of the key transnational political and economic forces that are shaping the 'global football field'. The model draws upon, and significantly extends, the theory of the 'global field' developed previously by Robertson. The model features four quadrants, each of which contains a dominant operating principle, an 'elemental reference point', and an 'elemental theme'. The quadrants contain, first, neo-liberalism, associated with the individual and elite football clubs; second, neo-mercantilism, associated with nation-states and national football systems; third, international relations, associated with international governing bodies; and fourth, global civil society, associated with diverse institutions that pursue human development and/or social justice. We examine some of the interactions and tensions between the major institutional and ideological forces across the four quadrants. We conclude by examining how the weakest quadrant, featuring global civil society, may gain greater prominence within football. In broad terms, we argue that our four-fold model may be utilized to map and to examine other substantive research fields with reference to globalization. © London School of Economics and Political Science 2012.
Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells
NASA Technical Reports Server (NTRS)
Lathrop, J. W.; Prince, J. L.
1980-01-01
Three tasks were undertaken to investigate reliability attributes of terrestrial solar cells: (1) a study of the electrical behavior of cells in the second (reverse) quadrant; (2) the accelerated stress testing of three new state-of-the-art cells; and (3) the continued bias-temperature testing of four block 2 type silicon cells at 78 C and 135 C. Electrical characteristics measured in the second quadrant were determined to be a function of the cell's thermal behavior with breakdown depending on the initiation of localized heating. This implied that high breakdown cells may be more fault tolerant when forced to operate in the second quadrant, a result contrary to conventional thinking. The accelerated stress tests used in the first (power) quadrant were bias-temperature, bias-temperature-humidity, temperature-humidity, thermal shock, and thermal cycle. The new type cells measured included an EFG cell, a polycrystalline cell, and a Czochralski cell. Significant differences in the response to the various tests were observed between cell types. A microprocessed controlled, short interval solar cell tester was designed and construction initiated on a prototype.
Dimbwadyo-Terrer, I; Gil-Agudo, A; Segura-Fragoso, A; de los Reyes-Guzmán, A; Trincado-Alonso, F; Piazza, S; Polonio-López, B
2016-01-01
The aim of this study was to investigate the effects of a virtual reality program combined with conventional therapy in upper limb function in people with tetraplegia and to provide data about patients' satisfaction with the virtual reality system. Thirty-one people with subacute complete cervical tetraplegia participated in the study. Experimental group received 15 sessions with Toyra(®) virtual reality system for 5 weeks, 30 minutes/day, 3 days/week in addition to conventional therapy, while control group only received conventional therapy. All patients were assessed at baseline, after intervention, and at three-month follow-up with a battery of clinical, functional, and satisfaction scales. Control group showed significant improvements in the manual muscle test (p = 0,043, partial η (2) = 0,22) in the follow-up evaluation. Both groups demonstrated clinical, but nonsignificant, changes to their arm function in 4 of the 5 scales used. All patients showed a high level of satisfaction with the virtual reality system. This study showed that virtual reality added to conventional therapy produces similar results in upper limb function compared to only conventional therapy. Moreover, the gaming aspects incorporated in conventional rehabilitation appear to produce high motivation during execution of the assigned tasks. This trial is registered with EudraCT number 2015-002157-35.
VirtualSpace: A vision of a machine-learned virtual space environment
NASA Astrophysics Data System (ADS)
Bortnik, J.; Sarno-Smith, L. K.; Chu, X.; Li, W.; Ma, Q.; Angelopoulos, V.; Thorne, R. M.
2017-12-01
Space borne instrumentation tends to come and go. A typical instrument will go through a phase of design and construction, be deployed on a spacecraft for several years while it collects data, and then be decommissioned and fade into obscurity. The data collected from that instrument will typically receive much attention while it is being collected, perhaps in the form of event studies, conjunctions with other instruments, or a few statistical surveys, but once the instrument or spacecraft is decommissioned, the data will be archived and receive progressively less attention with every passing year. This is the fate of all historical data, and will be the fate of data being collected by instruments even at the present time. But what if those instruments could come alive, and all be simultaneously present at any and every point in time and space? Imagine the scientific insights, and societal gains that could be achieved with a grand (virtual) heliophysical observatory that consists of every current and historical mission ever deployed? We propose that this is not just fantasy but is imminently doable with the data currently available, with the present computational resources, and with currently available algorithms. This project revitalizes existing data resources and lays the groundwork for incorporating data from every future mission to expand the scope and refine the resolution of the virtual observatory. We call this project VirtualSpace: a machine-learned virtual space environment.
Dimbwadyo-Terrer, I.; Gil-Agudo, A.; Segura-Fragoso, A.; de los Reyes-Guzmán, A.; Trincado-Alonso, F.; Piazza, S.; Polonio-López, B.
2016-01-01
The aim of this study was to investigate the effects of a virtual reality program combined with conventional therapy in upper limb function in people with tetraplegia and to provide data about patients' satisfaction with the virtual reality system. Thirty-one people with subacute complete cervical tetraplegia participated in the study. Experimental group received 15 sessions with Toyra® virtual reality system for 5 weeks, 30 minutes/day, 3 days/week in addition to conventional therapy, while control group only received conventional therapy. All patients were assessed at baseline, after intervention, and at three-month follow-up with a battery of clinical, functional, and satisfaction scales. Control group showed significant improvements in the manual muscle test (p = 0,043, partial η 2 = 0,22) in the follow-up evaluation. Both groups demonstrated clinical, but nonsignificant, changes to their arm function in 4 of the 5 scales used. All patients showed a high level of satisfaction with the virtual reality system. This study showed that virtual reality added to conventional therapy produces similar results in upper limb function compared to only conventional therapy. Moreover, the gaming aspects incorporated in conventional rehabilitation appear to produce high motivation during execution of the assigned tasks. This trial is registered with EudraCT number 2015-002157-35. PMID:26885511
Oestergaard, Jeanett; Bjerrum, Flemming; Maagaard, Mathilde; Winkel, Per; Larsen, Christian Rifbjerg; Ringsted, Charlotte; Gluud, Christian; Grantcharov, Teodor; Ottesen, Bent; Soerensen, Jette Led
2012-02-28
Several studies have found a positive effect on the learning curve as well as the improvement of basic psychomotor skills in the operating room after virtual reality training. Despite this, the majority of surgical and gynecological departments encounter hurdles when implementing this form of training. This is mainly due to lack of knowledge concerning the time and human resources needed to train novice surgeons to an adequate level. The purpose of this trial is to investigate the impact of instructor feedback regarding time, repetitions and self-perception when training complex operational tasks on a virtual reality simulator. The study population consists of medical students on their 4th to 6th year without prior laparoscopic experience. The study is conducted in a skills laboratory at a centralized university hospital. Based on a sample size estimation 98 participants will be randomized to an intervention group or a control group. Both groups have to achieve a predefined proficiency level when conducting a laparoscopic salpingectomy using a surgical virtual reality simulator. The intervention group receives standardized instructor feedback of 10 to 12 min a maximum of three times. The control group receives no instructor feedback. Both groups receive the automated feedback generated by the virtual reality simulator. The study follows the CONSORT Statement for randomized trials. Main outcome measures are time and repetitions to reach the predefined proficiency level on the simulator. We include focus on potential sex differences, computer gaming experience and self-perception. The findings will contribute to a better understanding of optimal training methods in surgical education. NCT01497782.
[Clinical and radiographic correlation after anterior cruciate ligament reconstruction].
González Perales, Aldo Alán; Negrete Corona, Jorge; Chávez Hinojosa, Edgard
2010-01-01
The purpose of this work is to correlate the clinical, functional and radiographic results of the anterior cruciate ligament (ACL) reconstruction with the angulation and orientation of the femoral and tibial tunnels. The ACL is one of the most frequently injured articular structures of the knee. The reason for this being that it is the primary limiting structure of anterior tibial translation; its tear causes kinematic alterations and results in long-term degenerative and functional changes. Repair can restore the kinematics. 26 patients, 20-50 years old, post-ACL reconstruction with the semitendinous-gracilis technique. From November 2006 to July 2007. Clinical and functional assessments: Tegner and Lysholm. Radiographic assessment: anteroposterior view with knee extension and lateral view with 30 degrees flexion. Pearson correlations (r) were used in the analysis. 26 patients (100%), 20 males (76.92%), 6 females (23.08%). Mean of 2.4 in the Lysholm scale (fair to good); standard deviation 1.2. Bernard-Lysholm quadrant r = -0.772. Tegner quadrant r = 0.790. The Lysholm and Tegner scale is associated with the graft quadrant. The situation of the tibial implant in the saggital plane is associated with the Lysholm scale. The correlation of patients with an inadequate placement with respect to the quadrants was associated with good-to-excellent results and fair-to-good results. Two patients had a poor clinical outcome; the orientation of the AP angle and the quadrant were within acceptable parameters, with the exception of the lateral angle-shaft axis.
Niu, Shaoqing; Wen, Ge; Ren, Yufeng; Li, Yiyang; Feng, Lingling; Wang, Chengtao; Huang, Xiaobo; Wen, Bixiu; Zhang, Yujing
2017-01-01
Introduction: It remains controversial on high risks for early breast cancer patients with one to three axillary nodes after mastectomy who is predisposition to locoregional recurrence. The present study is to investigate the relationship between primary tumor site and loco-regional recurrence (LRR) and explore the predictive value of clinicopathological characteristics in LRR for early breast cancer patients with one to three positive axillary lymph nodes after mastectomy. Methods: We reviewed the clinical data of 656 consecutively diagnosed patients with pT 1-2 N 1 M 0 breast cancer who were treated in Sun Yat-sen University Cancer Center with radical operation without postoperative radiotherapy between March 1998 and December 2010. The primary tumor sites included outer quadrant in 455 patients (69.36%), inner quadrant in 156 patients (23.78%)and central quadrant in 45 patients (6.86%). LRR and LRR-free survival (LRFS) in combination with clinical and pathological features were analyzed to screen out patients with higher risk of LRR. Results: The median follow-up time was 64.9 months. The 5-, 10-year LRR for the cohort was 8.6% and 12.9%, respectively; the 5-, 10-year LRFS was 86.2% and 76.4%, respectively. Multivariate analyses showed that age of ≤35 years, inner quadrant tumor and non-luminal subtype were independent risk factors for LRR and LRFS. Patients with primary tumor in inner quadrant showed higher LRR and poorer LRFS when risk factors are ≥2 than those with tumors in other sites. Conclusions: Inner quadrant tumor was an independent predictor for LRR and LRFS in patients with early breast cancer and one to three positive axillary lymph nodes, which would be more accurate in combination with other prognostic indexes including patients' age, pathological T stage, Ki67 status, molecular subtypes.
In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.
Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert
2016-09-01
Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. Impressions were obtained via two conventional (metal full-arch tray, CI, and triple tray, T-Tray) and seven digital impression systems (Lava True Definition Scanner, T-Def; Lava Chairside Oral Scanner, COS; Cadent iTero, ITE; 3Shape Trios, TRI; 3Shape Trios Color, TRC; CEREC Bluecam, Software 4.0, BC4.0; CEREC Bluecam, Software 4.2, BC4.2; and CEREC Omnicam, OC). Impressions were taken three times for each of five subjects (n = 15). The impressions were then superimposed within the test groups. Differences from model surfaces were measured using a normal surface distance method. Precision was calculated using the Perc90_10 value. The values for all test groups were statistically compared. The precision ranged from 18.8 (CI) to 58.5 μm (T-Tray), with the highest precision in the CI, T-Def, BC4.0, TRC, and TRI groups. The deviation pattern varied distinctly depending on the impression method. Impression systems with single-shot capture exhibited greater deviations at the tooth surface whereas high-frame rate impression systems differed more in gingival areas. Triple tray impressions displayed higher local deviation at the occlusal contact areas of upper and lower jaw. Digital quadrant impression methods achieve a level of precision, comparable to conventional impression techniques. However, there are significant differences in terms of absolute values and deviation pattern. With all tested digital impression systems, time efficient capturing of quadrant impressions is possible. The clinical precision of digital quadrant impression models is sufficient to cover a broad variety of restorative indications. Yet the precision differs significantly between the digital impression systems.
Abdellatif, Mona K; Fouad, Mohamed M
2018-03-01
To investigate the factors in migraine that have the highest significance on retinal and choroidal layers' thickness. Ninety patients with migraine and 40 age-matched healthy participants were enrolled in this observational, cross-sectional study. After full ophthalmological examination, spectral domain-optical coherence tomography was done for all patients measuring the thickness of ganglion cell layer and retinal nerve fiber layer. Enhanced depth imaging technique was used to measure the choroidal thickness. There was significant thinning in the superior and inferior ganglion cell layers, all retinal nerve fiber layer quadrants, and all choroidal quadrants (except for the central subfield) in migraineurs compared to controls. The duration of migraine was significantly correlated with ganglion cell layer, retinal nerve fiber layer, and all choroidal quadrants, while the severity of migraine was significantly correlated with ganglion cell layer and retinal nerve fiber layer only. Multiregression analysis showed that the duration of migraine is the most important determinant factor of the superior retinal nerve fiber layer quadrant (β = -0.375, p = 0.001) and in all the choroidal quadrants (β = -0.531, -0.692, -0.503, -0.461, -0.564, respectively, p < 0.001), while severity is the most important determinant factor of inferior, nasal, and temporal retinal nerve fiber layer quadrants (β = -0.256, -0.335, -0.308; p = 0.036, 0.005, 0.009, respectively) and the inferior ganglion cell layer hemisphere (β = -0.377 and p = 0.001). Ganglion cell layer, retinal nerve fiber layer, and choroidal thickness are significantly thinner in patients with migraine. The severity of migraine has more significant influence in the thinning of ganglion cell layer and retinal nerve fiber layer, while the duration of the disease affected the choroidal thickness more.
Mayo, Johnathan; Baur, Kilian; Wittmann, Frieder; Riener, Robert; Wolf, Peter
2018-01-01
Background Goal-directed reaching for real-world objects by humans is enabled through visual depth cues. In virtual environments, the number and quality of available visual depth cues is limited, which may affect reaching performance and quality of reaching movements. Methods We assessed three-dimensional reaching movements in five experimental groups each with ten healthy volunteers. Three groups used a two-dimensional computer screen and two groups used a head-mounted display. The first screen group received the typically recreated visual depth cues, such as aerial and linear perspective, occlusion, shadows, and texture gradients. The second screen group received an abstract minimal rendering lacking those. The third screen group received the cues of the first screen group and absolute depth cues enabled by retinal image size of a known object, which realized with visual renderings of the handheld device and a ghost handheld at the target location. The two head-mounted display groups received the same virtually recreated visual depth cues as the second or the third screen group respectively. Additionally, they could rely on stereopsis and motion parallax due to head-movements. Results and conclusion All groups using the screen performed significantly worse than both groups using the head-mounted display in terms of completion time normalized by the straight-line distance to the target. Both groups using the head-mounted display achieved the optimal minimum in number of speed peaks and in hand path ratio, indicating that our subjects performed natural movements when using a head-mounted display. Virtually recreated visual depth cues had a minor impact on reaching performance. Only the screen group with rendered handhelds could outperform the other screen groups. Thus, if reaching performance in virtual environments is in the main scope of a study, we suggest applying a head-mounted display. Otherwise, when two-dimensional screens are used, achievable performance is likely limited by the reduced depth perception and not just by subjects’ motor skills. PMID:29293512
Hierarchical virtual screening approaches in small molecule drug discovery.
Kumar, Ashutosh; Zhang, Kam Y J
2015-01-01
Virtual screening has played a significant role in the discovery of small molecule inhibitors of therapeutic targets in last two decades. Various ligand and structure-based virtual screening approaches are employed to identify small molecule ligands for proteins of interest. These approaches are often combined in either hierarchical or parallel manner to take advantage of the strength and avoid the limitations associated with individual methods. Hierarchical combination of ligand and structure-based virtual screening approaches has received noteworthy success in numerous drug discovery campaigns. In hierarchical virtual screening, several filters using ligand and structure-based approaches are sequentially applied to reduce a large screening library to a number small enough for experimental testing. In this review, we focus on different hierarchical virtual screening strategies and their application in the discovery of small molecule modulators of important drug targets. Several virtual screening studies are discussed to demonstrate the successful application of hierarchical virtual screening in small molecule drug discovery. Copyright © 2014 Elsevier Inc. All rights reserved.
McLay, Robert N; Baird, Alicia; Webb-Murphy, Jennifer; Deal, William; Tran, Lily; Anson, Heather; Klam, Warren; Johnston, Scott
2017-04-01
Virtual reality exposure therapy (VRET) is one of the few interventions supported by randomized controlled trials for the treatment of combat-related posttraumatic stress disorder (PTSD) in active duty service members. A comparative effectiveness study was conducted to determine if virtual reality technology itself improved outcomes, or if similar results could be achieved with a control exposure therapy (CET) condition. Service members with combat-related PTSD were randomly selected to receive nine weeks of VRET or CET. Assessors, but not therapists, were blinded. PTSD symptom improvement was assessed one week and 3 months after the conclusion of treatment using the clinician-administered PTSD scale (CAPS). A small crossover component was included. Results demonstrated that PTSD symptoms improved with both treatments, but there were no statistically significant differences between groups. Dropout rates were higher in VRET. Of those who received VRET, 13/42 (31%) showed >30% improvement on the CAPS, versus 16/43 (37%) who received CET. Three months after treatment, >30% improvement was seen in 10/33 (30%) of VRET participants and 12/33 (36%) in CET. Participants who crossed over (n = 11) showed no statistically significant improvements in a second round of treatment, regardless of condition. This study supported the utility of exposure therapy for PTSD, but did not support additional benefit by the inclusion of virtual reality.
The Effect of Virtual Reality Training on Unilateral Spatial Neglect in Stroke Patients
Kim, Yong Mi; Yun, Gi Jeong; Song, Young Jin; Young, Han Eun
2011-01-01
Objective To investigate the effect of virtual reality training on unilateral spatial neglect in stroke patients. Method Twenty-four stroke patients (14 males and 10 females, mean age=64.7) who had unilateral spatial neglect as a result of right hemisphere stroke were recruited. All patients were randomly assigned to either the virtual reality (VR) group (n=12) or the control group (n=12). The VR group received VR training, which stimulated the left side of their bodies. The control group received conventional neglect therapy such as visual scanning training. Both groups received therapy for 30 minutes a day, five days per week for three weeks. Outcome measurements included star cancellation test, line bisection test, Catherine Bergego scale (CBS), and the Korean version of modified Barthel index (K-MBI). These measurements were taken before and after treatment. Results There were no significant differences in the baseline characteristics and initial values between the two groups. The changes in star cancellation test results and CBS in the VR group were significantly higher than those of the control group after treatment. The changes in line bisection test score and the K-MBI in the VR group were not statistically significant. Conclusion This study suggests that virtual reality training may be a beneficial therapeutic technique on unilateral spatial neglect in stroke patients. PMID:22506138
Accurately Decoding Visual Information from fMRI Data Obtained in a Realistic Virtual Environment
2015-06-09
Center for Learning and Memory , The University of Texas at Austin, 100 E 24th Street, Stop C7000, Austin, TX 78712, USA afloren@utexas.edu Received: 18...information from fMRI data obtained in a realistic virtual environment. Front. Hum. Neurosci. 9:327. doi: 10.3389/fnhum.2015.00327 Accurately decoding...visual information from fMRI data obtained in a realistic virtual environment Andrew Floren 1*, Bruce Naylor 2, Risto Miikkulainen 3 and David Ress 4
Examining Sensory Quadrants in Autism
ERIC Educational Resources Information Center
Kern, Janet K.; Garver, Carolyn R.; Carmody, Thomas; Andrews, Alonzo A.; Trivedi, Madhukar H.; Mehta, Jyutika A.
2007-01-01
The purpose of this study was to examine sensory quadrants in autism based on Dunn's Theory of Sensory Processing. The data for this study was collected as part of a cross-sectional study that examined sensory processing (using the Sensory Profile) in 103 persons with autism, 3-43 years of age, compared to 103 age- and gender-matched community…
NASA Technical Reports Server (NTRS)
Rodriquez, Melissa C.; Calaway, M. C.; McNamara, K. M.; Hittle, J. D.
2009-01-01
In addition to passive solar wind collector surfaces, the Genesis Discovery Mission science canister had on board an electrostatic concave mirror for concentrating the solar wind ions, known as the concentrator . The 30-mm-radius collector focal point (the target) was comprised of 4 quadrants: two of single crystal SiC, one of polycrystalline 13C diamond and one of diamond-like-carbon (DLC) on a silicon substrate. [DLC-on-silicon is also sometimes referenced as Diamond-on-silicon, DOS.] Three of target quadrants survived the hard landing intact, but the DLC-on-silicon quadrant fractured into numerous pieces (Fig. 1). This abstract reports the status of identifying the DLC target fragments and reconstructing their original orientation.
Levenhagen, Kimberly; Davies, Claire; Perdomo, Marisa; Ryans, Kathryn
2017-01-01
Introduction: The Oncology Section of APTA developed a clinical practice guideline to aid the clinician in diagnosing secondary upper-quadrant cancer-related lymphedema. Methods: Following a systematic review of published studies and a structured appraisal process, recommendations were written to guide the physical therapist and other health care clinicians in their diagnostic process. Overall, clinical practice recommendations were formulated on the basis of the evidence for each diagnostic method and were assigned a grade based on the strength of the evidence for different patient presentations and clinical utility. Recommendations: In an effort to make these clinically applicable, recommendations were based on the characteristics as to the location and stage of a patient's upper-quadrant lymphedema. PMID:28748128
Ovariectomy ameliorates dextromethorphan - induced memory impairment in young female rats
Jahng, Jeong Won; Cho, Hee Jeong; Kim, Jae Goo; Kim, Nam Youl; Lee, Seoul; Lee, Yil Seob
2006-01-01
We have previously found that dextromethorphan (DM), over-the-counter cough suppressant, impairs memory retention in water maze task, when it is repeatedly administrated to adolescent female rats at high doses. In this study we examined first if ovariectomy ameliorates the DM-induced memory impairment in female rats, and then whether or not the DM effect is revived by estrogen replacement in ovariectomized female rats. Female rat pups received bilateral ovariectomy or sham operation on postnatal day (PND) 21, and then intraperitoneal DM (40 mg/kg) daily during PND 28–37. Rats were subjected to the Morris water maze task from PND 38, approximately 24 h after the last DM injection. In probe trial, goal quadrant dwell time was significantly reduced by DM in the sham operated group, however, the reduction by DM did not occur in the ovariectomy group. When 17β-estradiol was supplied to ovariectomized females during DM treatment, the goal quadrant dwell time was significantly decreased, compared to the vehicle control group. Furthermore, a major effect of estrogen replacement was found in the escape latency during the last 3 days of initial learning trials. These results suggest that ovariectomy may ameliorate the adverse effect of DM treatment on memory retention in young female rats, and that estrogen replacement may revive it, i.e. estrogen may take a major role in DM-induced memory impairment in female rats. PMID:16563229
IMMERSE: Interactive Mentoring for Multimodal Experiences in Realistic Social Encounters
2015-08-28
undergraduates funded by your agreement who graduated during this period and will receive scholarships or fellowships for further studies in science... Player Locomotion 9.2 Interacting with Real and Virtual Objects 9.3 Animation Combinations and Stage Management 10. Recommendations on the Way Ahead...Interaction with Virtual Characters ................................52! 9.1! Player Locomotion
Optimizing TLB entries for mixed page size storage in contiguous memory
Chen, Dong; Gara, Alan; Giampapa, Mark E.; Heidelberger, Philip; Kriegel, Jon K.; Ohmacht, Martin; Steinmacher-Burow, Burkhard
2013-04-30
A system and method for accessing memory are provided. The system comprises a lookup buffer for storing one or more page table entries, wherein each of the one or more page table entries comprises at least a virtual page number and a physical page number; a logic circuit for receiving a virtual address from said processor, said logic circuit for matching the virtual address to the virtual page number in one of the page table entries to select the physical page number in the same page table entry, said page table entry having one or more bits set to exclude a memory range from a page.
Meldrum, Dara; Herdman, Susan; Vance, Roisin; Murray, Deirdre; Malone, Kareena; Duffy, Douglas; Glennon, Aine; McConn-Walsh, Rory
2015-07-01
To compare the effectiveness of virtual reality-based balance exercises to conventional balance exercises during vestibular rehabilitation in patients with unilateral peripheral vestibular loss (UVL). Assessor-blind, randomized controlled trial. Two acute care university teaching hospitals. Patients with UVL (N=71) who had dizziness/vertigo, and gait and balance impairment. Patients with UVL were randomly assigned to receive 6 weeks of either conventional (n=36) or virtual reality-based (n=35) balance exercises during vestibular rehabilitation. The virtual reality-based group received an off-the-shelf virtual reality gaming system for home exercise, and the conventional group received a foam balance mat. Treatment comprised weekly visits to a physiotherapist and a daily home exercise program. The primary outcome was self-preferred gait speed. Secondary outcomes included other gait parameters and tasks, Sensory Organization Test (SOT), dynamic visual acuity, Hospital Anxiety and Depression Scale, Vestibular Rehabilitation Benefits Questionnaire, and Activities Balance Confidence Questionnaire. The subjective experience of vestibular rehabilitation was measured with a questionnaire. Both groups improved, but there were no significant differences in gait speed between the groups postintervention (mean difference, -.03m/s; 95% confidence interval [CI], -.09 to .02m/s). There were also no significant differences between the groups in SOT scores (mean difference, .82%; 95% CI, -5.00% to 6.63%) or on any of the other secondary outcomes (P>.05). In both groups, adherence to exercise was high (∼77%), but the virtual reality-based group reported significantly more enjoyment (P=.001), less difficulty with (P=.009) and less tiredness after (P=.03) balance exercises. At 6 months, there were no significant between-group differences in physical outcomes. Virtual reality-based balance exercises performed during vestibular rehabilitation were not superior to conventional balance exercises during vestibular rehabilitation but may provide a more enjoyable method of retraining balance after unilateral peripheral vestibular loss. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Ertugrul, Abdullah Seckin; Tekin, Yasin; Talmac, Ahmet Cemil
2017-11-01
The aim of this study is to determine the suitability of the Er,Cr:YSGG and 940 ± 15-nm diode laser for the treatment of generalized aggressive periodontitis and chronic periodontitis by measuring the levels of human β-defensin-1 and IL-1β. A total of 26 patients were included in this study. The study was designed as a "split-mouth" experiment. We performed scaling and root planing in the right maxillary quadrant, scaling and root planning + Er,Cr:YSGG laser in the left maxillary quadrant, scaling and root planning + 940 ± 15-nm diode laser in the left mandibular quadrant, and only scaling and root planing in the right mandibular quadrant. The presence of human β-defensin-1 and IL-1β was analyzed with an ELISA. When the baseline and post-treatment human β-defensin-1 levels and IL-1β levels of the study groups were evaluated, a decrease in human β-defensin-1 and IL-1β were observed in the quadrant where the Er,Cr:YSGG laser was applied in both the generalized aggressive periodontitis group and the chronic periodontitis group. The use of the Er,Cr:YSGG laser at non-surgical periodontal treatment decreased both IL-1β and human β-defensin-1 levels. It is likely that Er,Cr:YSGG laser is more suitable for the treatment of generalized aggressive periodontitis and chronic periodontitis.
Changes in retinal microvascular diameter in patients with diabetes
da Silva, Andréa Vasconcellos Batista; Gouvea, Sonia Alves; da Silva, Aurélio Paulo Batista; Bortolon, Saulo; Rodrigues, Anabel Nunes; Abreu, Glaucia Rodrigues; Herkenhoff, Fernando Luiz
2015-01-01
Background and objectives Diabetic retinopathy is the main microvascular complication in diabetes mellitus and needs to be diagnosed early to prevent severe sight-threatening retinopathy. The purpose of this study was to quantify the retinal microvasculature pattern and analyze the influence of blood glucose level and the duration of diabetes mellitus on the retinal microvasculature. Methods Two groups were analyzed: patients with diabetes (N=26) and patients without diabetes, ie, controls (N=26). A quantitative semiautomated method analyzed retinal microvasculature. The diameters of arterioles and venules were measured. The total numbers of arterioles and venules were counted. The ratio of arteriole diameter to venule diameter was calculated. The retinal microvasculature pattern was related to clinical and biochemical parameters. Results Patients with diabetes exhibited larger venule diameters in the upper temporal quadrant of the retina compared to the lower temporal quadrant (124.85±38.03 µm vs 102.92±15.69 µm; P<0.01). Patients with diabetes for 5 or more years had larger venule diameters in the upper temporal quadrant than patients without diabetes (141.62±44.44 vs 112.58±32.11 µm; P<0.05). The degree of venodilation in the upper temporal quadrant was positively correlated with blood glucose level and the estimated duration of diabetes mellitus. Interpretation and conclusion The employed quantitative method demonstrated that patients with diabetes exhibited venule dilation in the upper temporal quadrant, and the duration of diabetes mellitus was positively correlated with blood glucose level. Therefore, the early assessment of retinal microvascular changes is possible prior to the onset of diabetic retinopathy. PMID:26345217
Change in intraocular pressure during scleral depression.
Trevino, Richard; Stewart, Brandi
2015-01-01
Manometric studies have found that intraocular pressure (IOP) rises 116-350 mmHg during scleral depression in surgical settings. No information is available regarding the effect of scleral depression on IOP in routine clinical settings. The aim of this study is to quantify the change in IOP that occurs when scleral depression is performed on normal eyes in a routine clinical setting. A total of 28 eyes from 28 normal subjects were included. Tono-Pen tonometry was performed while scleral depression was performed in each of the two quadrants: superotemporal (ST) and inferonasal (IN). A post-procedure IOP measurement was obtained following each scleral depression examination. Both ST and IN quadrants were tested on all eyes, with the quadrant tested first chosen at random (15 ST, 13 IN). The mean IOP during scleral depression was 65.3 mmHg ST and 47.8 mmHg IN, with a maximum recorded IOP of 88 mmHg. The mean change in IOP for the ST quadrant was 51.9 ± 17.3 mmHg and 46.4 ± 16.0 mmHg for the right and left eyes, respectively. The mean change in IOP for the IN quadrant was 45.3 ± 22.7 mmHg and 16.8 ± 15.8 mmHg for the right and left eyes, respectively. Scleral depression as performed in a routine office setting produces wide fluctuations in IOP and may impair ocular perfusion. Additional studies are needed to determine the long-term consequences of routine scleral depression. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Virtual reality for the treatment of autism.
Strickland, D
1997-01-01
Autism is a mental disorder which has received attention in several unrelated studies using virtual reality. One of the first attempts was to diagnose children with special needs at Tokyo University using a sandbox playing technique. Although operating the computer controls proved to be too difficult for the individuals with autism in the Tokyo study, research at the University of Nottingham, UK, is successful in using VR as a learning aid for children with a variety of disorders including autism. Both centers used flat screen computer systems with virtual scenes. Another study which concentrated on using VR as a learning aid with an immersive headset system is described in detail in this chapter. Perhaps because of the seriousness of the disorder and the lack of effective treatments, autism has received more study than attention deficit disorders, although both would appear to benefit from many of the same technology features.
The effect of virtual reality gaming on dynamic balance in older adults.
Rendon, Abel Angel; Lohman, Everett B; Thorpe, Donna; Johnson, Eric G; Medina, Ernie; Bradley, Bruce
2012-07-01
physical therapy interventions that increase functional strength and balance have been shown to reduce falls in older adults. this study compared a virtual reality group (VRG) and a control group (CG). randomised controlled 6-week intervention with pre- and post-test evaluations. outpatient geriatric orthopaedic and balance physical therapy clinic. forty participants were randomised into two groups. the VRG received three different Nintendo® Wii FIT balance interventions three times per week for 6 weeks and the CG received no intervention. compared with the CG, post-intervention measurements showed significant improvements for the VRG in the 8-foot Up & Go test [median decrease of 1.0 versus -0.2 s, (P=0.038) and the Activities-specific Balance Confidence Scale (6.9 versus 1.3%) (P=0.038)]. virtual reality gaming provides clinicians with a useful tool for improving dynamic balance and balance confidence in older adults.
2012-01-01
Abstract Background Several studies have found a positive effect on the learning curve as well as the improvement of basic psychomotor skills in the operating room after virtual reality training. Despite this, the majority of surgical and gynecological departments encounter hurdles when implementing this form of training. This is mainly due to lack of knowledge concerning the time and human resources needed to train novice surgeons to an adequate level. The purpose of this trial is to investigate the impact of instructor feedback regarding time, repetitions and self-perception when training complex operational tasks on a virtual reality simulator. Methods/Design The study population consists of medical students on their 4th to 6th year without prior laparoscopic experience. The study is conducted in a skills laboratory at a centralized university hospital. Based on a sample size estimation 98 participants will be randomized to an intervention group or a control group. Both groups have to achieve a predefined proficiency level when conducting a laparoscopic salpingectomy using a surgical virtual reality simulator. The intervention group receives standardized instructor feedback of 10 to 12 min a maximum of three times. The control group receives no instructor feedback. Both groups receive the automated feedback generated by the virtual reality simulator. The study follows the CONSORT Statement for randomized trials. Main outcome measures are time and repetitions to reach the predefined proficiency level on the simulator. We include focus on potential sex differences, computer gaming experience and self-perception. Discussion The findings will contribute to a better understanding of optimal training methods in surgical education. Trial Registration NCT01497782 PMID:22373062
Code of Federal Regulations, 2010 CFR
2010-04-01
... Wholesale Electric Quadrant, which are incorporated herein by reference: (1) Open Access Same-Time....13, 001-1.0, 001-9.7, 001-14.1.3, and 001-15.1.2); (2) Open Access Same-Time Information Systems... minor corrections applied May 29, 2009 and September 8, 2009); (3) Open Access Same-Time Information...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Wholesale Electric Quadrant, which are incorporated herein by reference: (1) Open Access Same-Time....13, 001-1.0, 001-9.7, 001-14.1.3, and 001-15.1.2); (2) Open Access Same-Time Information Systems... minor corrections applied May 29, 2009 and September 8, 2009); (3) Open Access Same-Time Information...
67. Photocopy of Rudder Bearing Quadrant, Skeg and Rudder Stops. ...
67. Photocopy of Rudder Bearing Quadrant, Skeg and Rudder Stops. Erie Concrete & Steel Supply Company, Shipbuilding Division, Erie, Pennsylvania. Coast Guard Headquarters Drawing No. 540-WAGL-2200-17 (right side), dated May 1943. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA
66. Photocopy of Rudder Bearing Quadrant, Skeg and Rudder Stops. ...
66. Photocopy of Rudder Bearing Quadrant, Skeg and Rudder Stops. Erie Concrete & Steel Supply Company, Shipbuilding Division, Erie, Pennsylvania. Coast Guard Headquarters Drawing No. 540-WAGL-2200-17 (left side), dated May 1943. Original drawing property of the U.S. Coast Guard. - U.S. Coast Guard Cutter WHITE HEATH, USGS Integrated Support Command Boston, 427 Commercial Street, Boston, Suffolk County, MA
Code of Federal Regulations, 2011 CFR
2011-04-01
....13, 001-1.0, 001-9.7, 001-14.1.3, and 001-15.1.2); (2) Open Access Same-Time Information Systems... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...
ERIC Educational Resources Information Center
Beckmann, Jens F.
2015-01-01
In this article, I reflect on how ways of reporting research as well as reviewing and commenting on submitted manuscripts could take new directions to promote progress in the discipline of developmental science. I argue for (a) attitudinal openness toward migratory impulses in relation to Stokes's quadrant model of science, (b) the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new... clearance and any wire bundle damage between wire bundle W443 and the left forward rudder quadrant, followed by adjusting the minimum clearance between the wire bundle and the left forward rudder quadrant, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-18
...: We propose to adopt a new airworthiness directive (AD) for certain Model 737-600, -700, -700C, -800... and any wire bundle damage between wire bundle W443 and the left forward rudder quadrant, followed by adjusting the minimum clearance between the wire bundle and the left forward rudder quadrant, and repairing...
Concerning the Motion of FTEs and Attendant Signatures
NASA Technical Reports Server (NTRS)
Sibeck, David G.
2010-01-01
We employ the Cooling et al. [2001] model to predict the location, orientation, and motion of flux transfer events (FTEs) generated along finite length component and anti parallel reconnection lines for typical solar wind plasma conditions and various interplanetary magnetic field (IMF) orientations in the plane perpendicular to the SunEarth line at the solstices and equinoxes. For duskward and northward or southward IMF orientations, events formed by component reconnection originate along reconnection curves passing through the sub solar point that tilt from southern dawn to northern dusk. They maintain this orientation as they move either northward into the northern dawn quadrant or southward into the southern dusk quadrant. By contrast, events formed by antiparallel reconnection originate along reconnection curves running from northern dawn to southern dusk in the southern dawn and northern dusk quadrants and maintain these orientations as they move anti sunward into both these quadrants. Although both the component and antiparallel reconnection models can explain previously reported event orientations on the southern dusk magnetopause during intervals of northward and dawn ward IMF orientation, only the component model explains event occurrence near the subsolar magnetopause during intervals when the IMF does not point due southward.
Right Lower Quadrant Pain in a Young Female: Ultrasound Diagnosis of Rectus Abdominis Tear.
Minardi, Joseph; Shaver, Erica; Monseau, Aaron; Pratt, Adam; Layman, Shelley M
2015-11-01
Right lower quadrant pain in young females presents a frequent diagnostic challenge for emergency physicians, with a broad differential and several important diagnoses. Using an "ultrasound first" imaging strategy can help decrease the use of computed tomography scans, with associated savings in radiation exposure, cost, and other resource use. We report a case of right lower quadrant pain in a young woman. After her initial history and physical examination, appendicitis was the leading differential. A bedside ultrasound was performed, leading to the uncommon diagnosis of rectus abdominis muscle tear. The sonographic findings of a muscle tear include increase in size, loss of linear, homogeneous architecture, and decreased echogenicity. Making this diagnosis at the bedside using ultrasound obviated the need for further imaging, avoiding unnecessary radiation exposure, and decreasing emergency department length of stay and overall cost, while leading to a tailored treatment plan. Why Should an Emergency Physician Be Aware of This? Rectus abdominis tear is a cause of right lower quadrant pain that may mimic appendicitis and should be considered in patients with this complaint. The ability to make this diagnosis with bedside ultrasound may assist in several important patient-oriented outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.
Smith, Matthew J; Fleming, Michael F; Wright, Michael A; Roberts, Andrea G; Humm, Laura Boteler; Olsen, Dale; Bell, Morris D
2015-08-01
Individuals with schizophrenia have low employment rates and the job interview presents a critical barrier for them to obtain employment. Virtual reality training has demonstrated efficacy at improving interview skills and employment outcomes among multiple clinical populations. However, the effects of this training on individuals with schizophrenia are unknown. This study evaluated the efficacy of virtual reality job interview training (VR-JIT) at improving job interview skills and employment outcomes among individuals with schizophrenia in a small randomized controlled trial (n=21 VR-JIT trainees, n=11 waitlist controls). Trainees completed up to 10h of virtual interviews using VR-JIT, while controls received services as usual. Primary outcome measures included two pre-test and two post-test video-recorded role-play interviews scored by blinded raters with expertise in human resources and self-reported interviewing self-confidence. Six-month follow-up data on employment outcomes were collected. Trainees reported that the intervention was easy-to-use, helpful, and prepared them for future interviews. Trainees demonstrated increased role-play scores between pre-test and post-test while controls did not (p=0.001). After accounting for neurocognition and months since prior employment, trainees had greater odds of receiving a job offer by 6month follow-up compared to controls (OR: 8.73, p=0.04) and more training was associated with fewer weeks until receiving a job offer (r=-0.63, p<0.001). Results suggest that VR-JIT is acceptable to trainees and may be efficacious for improving job interview skills in individuals with schizophrenia. Moreover, trainees had greater odds of receiving a job offer by 6-month follow-up. Future studies could evaluate the effectiveness of VR-JIT within community-based services. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Stull, Andrew T.; Hegarty, Mary
2016-01-01
This study investigated the development of representational competence among organic chemistry students by using 3D (concrete and virtual) models as aids for teaching students to translate between multiple 2D diagrams. In 2 experiments, students translated between different diagrams of molecules and received verbal feedback in 1 of the following 3…
ERIC Educational Resources Information Center
West, Jessica A.; Saine, Paula
2017-01-01
This article describes the Mentored Multigenre Project, a virtual writing collaboration experience between high school writers and teacher candidates. Our goal was to create an authentic opportunity for our high school students to receive writing feedback from virtual writing mentors, while also creating an opportunity for our teacher candidates…
Levenhagen, Kimberly; Davies, Claire; Perdomo, Marisa; Ryans, Kathryn
2017-01-01
Abstract The Oncology Section of the American Physical Therapy Association (APTA) developed a clinical practice guideline to aid the clinician in diagnosing secondary upper quadrant cancer-related lymphedema. Following a systematic review of published studies and a structured appraisal process, recommendations were written to guide the physical therapist and other health care clinicians in the diagnostic process. Overall clinical practice recommendations were formulated based on the evidence for each diagnostic method and were assigned a grade based on the strength of the evidence for different patient presentations and clinical utility. In an effort to maximize clinical applicability, recommendations were based on the characteristics as to the location and stage of a patient's upper quadrant lymphedema. PMID:28838217
Reliability testing of ultra-low noise InGaAs quad photoreceivers
NASA Astrophysics Data System (ADS)
Joshi, Abhay M.; Datta, Shubhashish; Prasad, Narasimha; Sivertz, Michael
2018-02-01
We have developed ultra-low noise quadrant InGaAs photoreceivers for multiple applications ranging from Laser Interferometric Gravitional Wave Detection, to 3D Wind Profiling. Devices with diameters of 0.5 mm, 1mm, and 2 mm were processed, with the nominal capacitance of a single quadrant of a 1 mm quad photodiode being 2.5 pF. The 1 mm diameter InGaAs quad photoreceivers, using a low-noise, bipolar-input OpAmp circuitry exhibit an equivalent input noise per quadrant of <1.7 pA/√Hz in 2 to 20 MHz frequency range. The InGaAs Quad Photoreceivers have undergone the following reliability tests: 30 MeV Proton Radiation up to a Total Ionizing Dose (TID) of 50 krad, Mechanical Shock, and Sinusoidal Vibration.
NASA Astrophysics Data System (ADS)
Entwistle, Elizabeth; Curtis, Andrew; Galetti, Erica; Baptie, Brian; Meles, Giovanni
2015-04-01
If energy emitted by a seismic source such as an earthquake is recorded on a suitable backbone array of seismometers, source-receiver interferometry (SRI) is a method that allows those recordings to be projected to the location of another target seismometer, providing an estimate of the seismogram that would have been recorded at that location. Since the other seismometer may not have been deployed at the time the source occurred, this renders possible the concept of 'retrospective seismology' whereby the installation of a sensor at one period of time allows the construction of virtual seismograms as though that sensor had been active before or after its period of installation. Using the benefit of hindsight of earthquake location or magnitude estimates, SRI can establish new measurement capabilities closer to earthquake epicenters, thus potentially improving earthquake location estimates. Recently we showed that virtual SRI seismograms can be constructed on target sensors in both industrial seismic and earthquake seismology settings, using both active seismic sources and ambient seismic noise to construct SRI propagators, and on length scales ranging over 5 orders of magnitude from ~40 m to ~2500 km[1]. Here we present the results from earthquake seismology by comparing virtual earthquake seismograms constructed at target sensors by SRI to those actually recorded on the same sensors. We show that spatial integrations required by interferometric theory can be calculated over irregular receiver arrays by embedding these arrays within 2D spatial Voronoi cells, thus improving spatial interpolation and interferometric results. The results of SRI are significantly improved by restricting the backbone receiver array to include approximately those receivers that provide a stationary phase contribution to the interferometric integrals. We apply both correlation-correlation and correlation-convolution SRI, and show that the latter constructs virtual seismograms with fewer non-physical arrivals. Finally we reconstruct earthquake seismograms at sensors that were previously active but were subsequently removed before the earthquakes occurred; thus we create virtual earthquake seismograms at those sensors, truly retrospectively. Such SRI seismograms can be used to create a catalogue of new, virtual earthquake seismograms that are available to complement real earthquake data in future earthquake seismology studies. [1]E. Entwistle, Curtis, A., Galetti, E., Baptie, B., Meles, G., Constructing new seismograms from old earthquakes: Retrospective seismology at multiple length scales, JGR, in press.
Dawson, Debra Ann; Lam, Jack; Lewis, Lindsay B.; Carbonell, Felix; Mendola, Janine D.
2016-01-01
Abstract Numerous studies have demonstrated functional magnetic resonance imaging (fMRI)-based resting-state functional connectivity (RSFC) between cortical areas. Recent evidence suggests that synchronous fluctuations in blood oxygenation level-dependent fMRI reflect functional organization at a scale finer than that of visual areas. In this study, we investigated whether RSFCs within and between lower visual areas are retinotopically organized and whether retinotopically organized RSFC merely reflects cortical distance. Subjects underwent retinotopic mapping and separately resting-state fMRI. Visual areas V1, V2, and V3, were subdivided into regions of interest (ROIs) according to quadrants and visual field eccentricity. Functional connectivity (FC) was computed based on Pearson's linear correlation (correlation), and Pearson's linear partial correlation (correlation between two time courses after the time courses from all other regions in the network are regressed out). Within a quadrant, within visual areas, all correlation and nearly all partial correlation FC measures showed statistical significance. Consistently in V1, V2, and to a lesser extent in V3, correlation decreased with increasing eccentricity separation. Consistent with previously reported monkey anatomical connectivity, correlation/partial correlation values between regions from adjacent areas (V1-V2 and V2-V3) were higher than those between nonadjacent areas (V1-V3). Within a quadrant, partial correlation showed consistent significance between regions from two different areas with the same or adjacent eccentricities. Pairs of ROIs with similar eccentricity showed higher correlation/partial correlation than pairs distant in eccentricity. Between dorsal and ventral quadrants, partial correlation between common and adjacent eccentricity regions within a visual area showed statistical significance; this extended to more distant eccentricity regions in V1. Within and between quadrants, correlation decreased approximately linearly with increasing distances separating the tested ROIs. Partial correlation showed a more complex dependence on cortical distance: it decreased exponentially with increasing distance within a quadrant, but was best fit by a quadratic function between quadrants. We conclude that RSFCs within and between lower visual areas are retinotopically organized. Correlation-based FC is nonselectively high across lower visual areas, even between regions that do not share direct anatomical connections. The mechanisms likely involve network effects caused by the dense anatomical connectivity within this network and projections from higher visual areas. FC based on partial correlation, which minimizes network effects, follows expectations based on direct anatomical connections in the monkey visual cortex better than correlation. Last, partial correlation-based retinotopically organized RSFC reflects more than cortical distance effects. PMID:26415043
NASA Technical Reports Server (NTRS)
Natanson, G. A.
1997-01-01
New algorithms are described covering the simulation, processing, and calibration of penetration angles of the Barnes static Earth sensor assembly (SESA) as implemented in the Goddard Space Flight Center Flight Dynamics Division ground support system for the Tropical Rainfall Measuring Mission (TRMM) Observatory. The new treatment involves a detailed analysis of the measurements by individual quadrants. It is shown that, to a good approximation, individual quadrant misalignments can be treated simply as penetration angle biases. Simple formulas suitable for real-time applications are introduced for computing quadrant-dependent effects. The simulator generates penetration angles by solving a quadratic equation with coefficients uniquely determined by the spacecraft's position and the quadrant's orientation in GeoCentric Inertial (GCI) coordinates. Measurement processing for attitude determination is based on linearized equations obtained by expanding the coefficients of the aforementioned quadratic equation as a Taylor series in both the Earth oblateness coefficient (alpha approx. 1/150) and the angle between the pointing axis and the geodetic nadir vector. A simple formula relating a measured value of the penetration angle to the deviation of the Earth-pointed axis from the geodetic nadir vector is derived. It is shown that even near the very edge of the quadrant's Field Of View (FOV), attitude errors resulting from quadratic effects are a few hundredths of a degree, which is small compared to the attitude determination accuracy requirement (0.18 degree, 3 sigma) of TRMM. Calibration of SESA measurements is complicated by a first-order filtering used in the TRMM onboard algorithm to compute penetration angles from raw voltages. A simple calibration scheme is introduced where these complications are avoided by treating penetration angles as the primary raw measurements, which are adjusted using biases and scale factors. In addition to three misalignment parameters, the calibration state vector contains only two average penetration angle biases (one per each pair of opposite quadrants) since, because of the very narrow sensor FOV (+/- 2.6 degrees), differences between biases of the penetration angles measured by opposite quadrants cannot be distinguished from roll and pitch sensor misalignments. After calibration, the estimated misalignments and average penetration angle biases are converted to the four penetration angle biases and to the yaw misalignment angle. The resultant biases and the estimated scale factors are finally used to update the coefficients necessary for onboard computations of penetration angles from measured voltages.
Dawson, Debra Ann; Lam, Jack; Lewis, Lindsay B; Carbonell, Felix; Mendola, Janine D; Shmuel, Amir
2016-02-01
Numerous studies have demonstrated functional magnetic resonance imaging (fMRI)-based resting-state functional connectivity (RSFC) between cortical areas. Recent evidence suggests that synchronous fluctuations in blood oxygenation level-dependent fMRI reflect functional organization at a scale finer than that of visual areas. In this study, we investigated whether RSFCs within and between lower visual areas are retinotopically organized and whether retinotopically organized RSFC merely reflects cortical distance. Subjects underwent retinotopic mapping and separately resting-state fMRI. Visual areas V1, V2, and V3, were subdivided into regions of interest (ROIs) according to quadrants and visual field eccentricity. Functional connectivity (FC) was computed based on Pearson's linear correlation (correlation), and Pearson's linear partial correlation (correlation between two time courses after the time courses from all other regions in the network are regressed out). Within a quadrant, within visual areas, all correlation and nearly all partial correlation FC measures showed statistical significance. Consistently in V1, V2, and to a lesser extent in V3, correlation decreased with increasing eccentricity separation. Consistent with previously reported monkey anatomical connectivity, correlation/partial correlation values between regions from adjacent areas (V1-V2 and V2-V3) were higher than those between nonadjacent areas (V1-V3). Within a quadrant, partial correlation showed consistent significance between regions from two different areas with the same or adjacent eccentricities. Pairs of ROIs with similar eccentricity showed higher correlation/partial correlation than pairs distant in eccentricity. Between dorsal and ventral quadrants, partial correlation between common and adjacent eccentricity regions within a visual area showed statistical significance; this extended to more distant eccentricity regions in V1. Within and between quadrants, correlation decreased approximately linearly with increasing distances separating the tested ROIs. Partial correlation showed a more complex dependence on cortical distance: it decreased exponentially with increasing distance within a quadrant, but was best fit by a quadratic function between quadrants. We conclude that RSFCs within and between lower visual areas are retinotopically organized. Correlation-based FC is nonselectively high across lower visual areas, even between regions that do not share direct anatomical connections. The mechanisms likely involve network effects caused by the dense anatomical connectivity within this network and projections from higher visual areas. FC based on partial correlation, which minimizes network effects, follows expectations based on direct anatomical connections in the monkey visual cortex better than correlation. Last, partial correlation-based retinotopically organized RSFC reflects more than cortical distance effects.
Advanced Imaging Technologies for the Detection of Dysplasia and Early Cancer in Barrett Esophagus
Espino, Alberto; Cirocco, Maria; DaCosta, Ralph
2014-01-01
Advanced esophageal adenocarcinomas arising from Barrett esophagus (BE) are tumors with an increasing incidence and poor prognosis. The aim of endoscopic surveillance of BE is to detect dysplasia, particularly high-grade dysplasia and intramucosal cancers that can subsequently be treated endoscopically before progression to invasive cancer with lymph node metastases. Current surveillance practice standards require the collection of random 4-quadrant biopsy specimens over every 1 to 2 cm of BE (Seattle protocol) to detect dysplasia with the assistance of white light endoscopy, in addition to performing targeted biopsies of recognizable lesions. This approach is labor-intensive but should currently be considered state of the art. Chromoendoscopy, virtual chromoendoscopy (e.g., narrow band imaging), and confocal laser endomicroscopy, in addition to high-definition standard endoscopy, might increase the diagnostic yield for the detection of dysplastic lesions. Until these modalities have been demonstrated to enhance efficiency or cost effectiveness, the standard protocol will remain careful examination using conventional off the shelf high-resolution endoscopes, combined with as longer inspection time which is associated with increased detection of dysplasia. PMID:24570883
Konstantatos, A H; Angliss, M; Costello, V; Cleland, H; Stafrace, S
2009-06-01
Pain arising in burns sufferers is often severe and protracted. The prospect of a dressing change can heighten existing pain by impacting both physically and psychologically. In this trial we examined whether pre-procedural virtual reality guided relaxation added to patient controlled analgesia with morphine reduced pain severity during awake dressings changes in burns patients. We conducted a prospective randomized clinical trial in all patients with burns necessitating admission to a tertiary burns referral centre. Eligible patients requiring awake dressings changes were randomly allocated to single use virtual reality relaxation plus intravenous morphine patient controlled analgesia (PCA) infusion or to intravenous morphine patient controlled analgesia infusion alone. Patients rated their worst pain intensity during the dressing change using a visual analogue scale. The primary outcome measure was presence of 30% or greater difference in pain intensity ratings between the groups in estimation of worst pain during the dressing change. Of 88 eligible and consenting patients having awake dressings changes, 43 were assigned to virtual reality relaxation plus intravenous morphine PCA infusion and 43 to morphine PCA infusion alone. The group receiving virtual reality relaxation plus morphine PCA infusion reported significantly higher pain intensities during the dressing change (mean=7.3) compared with patients receiving morphine PCA alone (mean=5.3) (p=0.003) (95% CI 0.6-2.8). The addition of virtual reality guided relaxation to morphine PCA infusion in burns patients resulted in a significant increase in pain experienced during awake dressings changes. In the absence of a validated predictor for responsiveness to virtual reality relaxation such a therapy cannot be recommended for general use in burns patients having awake dressings changes.
Moazami, Fariborz; Bahrampour, Ehsan; Azar, Mohammad Reza; Jahedi, Farzad; Moattari, Marzieh
2014-03-05
The importance of using technologies such as e-learning in different disciplines is discussed in the literature. Researchers have measured the effectiveness of e-learning in a number of fields.Considering the lack of research on the effectiveness of online learning in dental education particularly in Iran, the advantages of these learning methods and the positive university atmosphere regarding the use of online learning. This study, therefore, aims to compare the effects of two methods of teaching (virtual versus traditional) on student learning. This post-test only design study approached 40, fifth year dental students of Shiraz University of Medical Sciences. From this group, 35 students agreed to participate. These students were randomly allocated into two groups, experimental (virtual learning) and comparison (traditional learning). To ensure similarity between groups, we compared GPAs of all participants by the Mann-Whitney U test (P > 0.05). The experimental group received a virtual learning environment courseware package specifically designed for this study, whereas the control group received the same module structured in a traditional lecture form. The virtual learning environment consisted of online and offline materials. Two identical valid, reliable post-tests that consisted of 40 multiple choice questions (MCQs) and 4 essay questions were administered immediately (15 min) after the last session and two months later to assess for knowledge retention. Data were analyzed by SPSS version 20. A comparison of the mean knowledge score of both groups showed that virtual learning was more effective than traditional learning (effect size = 0.69). The newly designed virtual learning package is feasible and will result in more effective learning in comparison with lecture-based training. However further studies are needed to generalize the findings of this study.
Wang, Zun-Rong; Wang, Ping; Xing, Liang; Mei, Li-Ping; Zhao, Jun; Zhang, Tong
2017-11-01
Virtual reality is nowadays used to facilitate motor recovery in stroke patients. Most virtual reality studies have involved chronic stroke patients; however, brain plasticity remains good in acute and subacute patients. Most virtual reality systems are only applicable to the proximal upper limbs (arms) because of the limitations of their capture systems. Nevertheless, the functional recovery of an affected hand is most difficult in the case of hemiparesis rehabilitation after a stroke. The recently developed Leap Motion controller can track the fine movements of both hands and fingers. Therefore, the present study explored the effects of a Leap Motion-based virtual reality system on subacute stroke. Twenty-six subacute stroke patients were assigned to an experimental group that received virtual reality training along with conventional occupational rehabilitation, and a control group that only received conventional rehabilitation. The Wolf motor function test (WMFT) was used to assess the motor function of the affected upper limb; functional magnetic resonance imaging was used to measure the cortical activation. After four weeks of treatment, the motor functions of the affected upper limbs were significantly improved in all the patients, with the improvement in the experimental group being significantly better than in the control group. The action performance time in the WMFT significantly decreased in the experimental group. Furthermore, the activation intensity and the laterality index of the contralateral primary sensorimotor cortex increased in both the experimental and control groups. These results confirmed that Leap Motion-based virtual reality training was a promising and feasible supplementary rehabilitation intervention, could facilitate the recovery of motor functions in subacute stroke patients. The study has been registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-OCH-12002238).
Wang, Zun-rong; Wang, Ping; Xing, Liang; Mei, Li-ping; Zhao, Jun; Zhang, Tong
2017-01-01
Virtual reality is nowadays used to facilitate motor recovery in stroke patients. Most virtual reality studies have involved chronic stroke patients; however, brain plasticity remains good in acute and subacute patients. Most virtual reality systems are only applicable to the proximal upper limbs (arms) because of the limitations of their capture systems. Nevertheless, the functional recovery of an affected hand is most difficult in the case of hemiparesis rehabilitation after a stroke. The recently developed Leap Motion controller can track the fine movements of both hands and fingers. Therefore, the present study explored the effects of a Leap Motion-based virtual reality system on subacute stroke. Twenty-six subacute stroke patients were assigned to an experimental group that received virtual reality training along with conventional occupational rehabilitation, and a control group that only received conventional rehabilitation. The Wolf motor function test (WMFT) was used to assess the motor function of the affected upper limb; functional magnetic resonance imaging was used to measure the cortical activation. After four weeks of treatment, the motor functions of the affected upper limbs were significantly improved in all the patients, with the improvement in the experimental group being significantly better than in the control group. The action performance time in the WMFT significantly decreased in the experimental group. Furthermore, the activation intensity and the laterality index of the contralateral primary sensorimotor cortex increased in both the experimental and control groups. These results confirmed that Leap Motion-based virtual reality training was a promising and feasible supplementary rehabilitation intervention, could facilitate the recovery of motor functions in subacute stroke patients. The study has been registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-OCH-12002238). PMID:29239328
Assessment of radiation awareness training in immersive virtual environments
NASA Astrophysics Data System (ADS)
Whisker, Vaughn E., III
The prospect of new nuclear power plant orders in the near future and the graying of the current workforce create a need to train new personnel faster and better. Immersive virtual reality (VR) may offer a solution to the training challenge. VR technology presented in a CAVE Automatic Virtual Environment (CAVE) provides a high-fidelity, one-to-one scale environment where areas of the power plant can be recreated and virtual radiation environments can be simulated, making it possible to safely expose workers to virtual radiation in the context of the actual work environment. The use of virtual reality for training is supported by many educational theories; constructivism and discovery learning, in particular. Educational theory describes the importance of matching the training to the task. Plant access training and radiation worker training, common forms of training in the nuclear industry, rely on computer-based training methods in most cases, which effectively transfer declarative knowledge, but are poor at transferring skills. If an activity were to be added, the training would provide personnel with the opportunity to develop skills and apply their knowledge so they could be more effective when working in the radiation environment. An experiment was developed to test immersive virtual reality's suitability for training radiation awareness. Using a mixed methodology of quantitative and qualitative measures, the subjects' performances before and after training were assessed. First, subjects completed a pre-test to measure their knowledge prior to completing any training. Next they completed unsupervised computer-based training, which consisted of a PowerPoint presentation and a PDF document. After completing a brief orientation activity in the virtual environment, one group of participants received supplemental radiation awareness training in a simulated radiation environment presented in the CAVE, while a second group, the control group, moved directly to the assessment phase of the experiment. The CAVE supplied an activity-based training environment where learners were able to use a virtual survey meter to explore the properties of radiation sources and the effects of time and distance on radiation exposure. Once the training stage had ended, the subjects completed an assessment activity where they were asked to complete four tasks in a simulated radiation environment in the CAVE, which was designed to provide a more authentic assessment than simply testing understanding using a quiz. After the practicum, the subjects completed a post-test. Survey information was also collected to assist the researcher with interpretation of the collected data. Response to the training was measured by completion time, radiation exposure received, successful completion of the four tasks in the practicum, and scores on the post-test. These results were combined to create a radiation awareness score. In addition, observational data was collected as the subjects completed the tasks. The radiation awareness scores of the control group and the group that received supplemental training in the virtual environment were compared. T-tests showed that the effect of the supplemental training was not significant; however, calculation of the effect size showed a small-to-medium effect of the training. The CAVE group received significantly less radiation exposure during the assessment activity, and they completed the activities on an average of one minute faster. These results indicate that the training was effective, primarily for instilling radiation sensitivity. Observational data collected during the assessment supports this conclusion. The training environment provided by the immersive virtual reality recreated a radiation environment where learners could apply knowledge they had been taught by computer-based training. Activity-based training has been shown to be a more effective way to transfer skills because of the similarity between the training environment and the application environment. Virtual reality enables the training environment to look and feel like the application environment. Because of this, radiation awareness training in an immersive virtual environment should be considered by the nuclear industry, which is supported by the results of this experiment.
Liaw, Sok Ying; Chan, Sally Wai-Chi; Chen, Fun-Gee; Hooi, Shing Chuan; Siau, Chiang
2014-09-17
Virtual patient simulation has grown substantially in health care education. A virtual patient simulation was developed as a refresher training course to reinforce nursing clinical performance in assessing and managing deteriorating patients. The objective of this study was to describe the development of the virtual patient simulation and evaluate its efficacy, by comparing with a conventional mannequin-based simulation, for improving the nursing students' performances in assessing and managing patients with clinical deterioration. A randomized controlled study was conducted with 57 third-year nursing students who were recruited through email. After a baseline evaluation of all participants' clinical performance in a simulated environment, the experimental group received a 2-hour fully automated virtual patient simulation while the control group received 2-hour facilitator-led mannequin-based simulation training. All participants were then re-tested one day (first posttest) and 2.5 months (second posttest) after the intervention. The participants from the experimental group completed a survey to evaluate their learning experiences with the newly developed virtual patient simulation. Compared to their baseline scores, both experimental and control groups demonstrated significant improvements (P<.001) in first and second post-test scores. While the experimental group had significantly lower (P<.05) second post-test scores compared with the first post-test scores, no significant difference (P=.94) was found between these two scores for the control group. The scores between groups did not differ significantly over time (P=.17). The virtual patient simulation was rated positively. A virtual patient simulation for a refreshing training course on assessing and managing clinical deterioration was developed. Although the randomized controlled study did not show that the virtual patient simulation was superior to mannequin-based simulation, both simulations have demonstrated to be effective refresher learning strategies for improving nursing students' clinical performance. Given the greater resource requirements of mannequin-based simulation, the virtual patient simulation provides a more promising alternative learning strategy to mitigate the decay of clinical performance over time.
1990-05-15
reference to indicate the exact time of the transmitted pulse. The returned pulses are detected using a four - quadrant photomultiplie tube, and each quadrant ...1990) Nondegencrate Four -Wave Mixing K.B. Nichols DTIC AD-A221419 in AlGaAs Waveguides W.D. Goodhue Wafer Fusion: A Novel Technique Z.L. Liau Appl...Annealing H.J. Zeiger (1990) of Etched Compound Semiconductor Structures: Theoretical Modeling and Experimental Confirmation Programmable, Four -Channel
ETR, TRA642. BASEMENT SPACE ALLOCATION FOR EXPERIMENTERS CA. 1966, SOUTHEAST ...
ETR, TRA-642. BASEMENT SPACE ALLOCATION FOR EXPERIMENTERS CA. 1966, SOUTHEAST QUADRANT OF FLOOR. WESTINGHOUSE ATOMIC POWER DIVISION (WAPD) AND BETTIS ATOMIC POWER LABORATORY (BAPL) CONSUME MOST OF THE QUADRANT. PHILLIPS PETROLEUM COMPANY ETR-E-2256, 12/1966. INL INDEX NO. 532-0642-00-706-021256, REV. F. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Earth Observations taken by STS-115 crewmember
2006-09-19
S115-E-07595 (19 Sept. 2006) --- A crewmember aboard the Space Shuttle Atlantis recorded this digital still image of part of the eastern Mediterranean area. The Gulf of Suez, Gulf of Aqaba, Dead Sea, Tel Aviv and Jerusalem all are visible in the upper left quadrant. Jordan is in the lower left quadrant. The Golan Heights and Haifa appear in the lower right quarter.
Investigating a Quadrant Surface Coil Array for NQR Remote Sensing
2014-10-23
UNCLASSIFIED 1 Abstract—this paper is on the design and fabrication of a surface coil array in a quadrant layout for NQR (Nuclear Quadrupole...coupling and SNR (Signal-to-Noise Ratio) at standoff distances perpendicular from each coil. Index Terms— Nuclear Quadrupole Resonance, NQR ...Coil Array, probe, Nuclear Magnetic Resonance, tuning, decoupling, RLC, mutual coupling, RLC I. INTRODUCTION N Nuclear quadrupole resonance ( NQR
Using virtual reality to train children in safe street-crossing skills.
Schwebel, David C; McClure, Leslie A
2010-02-01
Pedestrian injuries are among the leading causes of morbidity and mortality in middle childhood. One limitation to existing pedestrian safety interventions is that they do not provide children with repeated practice needed to develop the complex perceptual and cognitive skills required for safe street crossing. Virtual reality offers training through repeated unsupervised practice without risk, automated feedback on success of crossings, adjustment of traffic to match children's skill and a fun, appealing environment for training. To test the efficacy of virtual reality to train child pedestrians in safe street crossing. Birmingham, Alabama, USA. A randomised controlled trial is underway with an expected sample of four groups of 60 children aged 7-8 years (total N=240). One group receives training in an interactive, immersive virtual pedestrian environment. A second receives pedestrian safety training via widely used video and computer strategies. The third group receives what is judged to be the most efficacious treatment currently available, individualised behavioural training at streetside locations. The fourth group serves as a no-contact control group. All participants are exposed to a range of field and laboratory-based measures of pedestrian skill during baseline and post-intervention visits, as well as during a 6-month follow-up assessment. Primary analyses will be conducted through linear mixed models testing change over time in the four intervention groups. Three pedestrian safety measures will serve as primary outcomes: temporal gap before initiating crossing, temporal gap remaining after crossing and attention to traffic while waiting to cross.
Hasenöhrl, R U; Gerhardt, P; Huston, J P
1992-02-01
The conditioned corral preference paradigm was used to assess reinforcing effects of substance P (SP) and its N- and C-terminal fragments injected unilaterally into the region of the nucleus basalis magnocellularis (NBM) in rats. Behavioral testing was carried out in a circular open field, consisting of 4 quadrants equally preferred by the animals prior to conditioning. A single conditioning trial was performed. Rats received one microinjection (0.5 microliter) of SP (0.74 pmol), of the N-terminal fragment SP (1-7) and the C-terminal fragment analog DiMe-C7 (each at doses of 0.074, 0.74, and 74 pmol), or vehicle (phosphate-buffered saline; PBS). After injection the rats were placed into the open field with the four quadrants being separated by Plexiglas barriers (closed corral). During the test for conditioned corral preference, when provided a choice between the four quadrants, only those rats injected with SP and the equimolar dose of DiMe-C7 (0.74 pmol) spent more time in the treatment corral, indicative of a positively reinforcing action. None of the other doses of DiMe-C7 and of SP(1-7) influenced the preference behavior. For rats injected with 0.74 pmol SP, SP (1-7), and DiMe-C7, a behavioral analysis was performed for the 15 min conditioning trial. SP and DiMe-C7 reduced rearing and grooming behavior, whereas DiMe-C7 and SP(1-7) increased locomotor activity. However, the acute behavioral effects of SP and its fragments were not correlated with the subsequent place preference behavior during the test trial. The results are discussed in the framework of a structure/activity relationship for the positively reinforcing properties of SP in the region of the NBM. Furthermore, neuropathological implications of the present data are considered, since the homologous nucleus basalis of Meynert in man is known to degenerate in Alzheimer's disease, which is characterized behaviorally by a progressive deterioration in associative functioning.
Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batista Nogueira, Luciana; Lemos Silva, Hugo Leonardo; Donato da Silva, Sabrina
This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic filmsmore » EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)« less
NASA Astrophysics Data System (ADS)
Zhang, Zhuoying; Yang, Hong; Shi, Minjun
2016-04-01
The North China Plain is the most water scarce region in China. Its water security is closely relevant to interregional water movement, which can be realized by real water transfers and/or virtual water transfers. This study investigates the roles of virtual water trade and real water transfer using Interregional Input-Output model. The results show that the region is receiving 19.4 billion m3/year of virtual water from the interregional trade, while exporting 16.4 billion m3/year of virtual water in the international trade. In balance, the region has a net virtual water gain of 3 billion m3/year from outside. Its virtual water inflow is dominated by agricultural products from other provinces, totalling 16.6 billion m3/year, whilst its virtual water export is dominated by manufacturing sectors to other countries, totalling 11.7 billion m3/year. Both virtual water import and real water transfer from South to North Water Diversion Project are important water supplements for the region. The results of this study provide useful scientific references for the establishment of combating strategies to deal with the water scarcity in the future.
Machado, Michely Ediani; Tomazoni, Fernanda; Casarin, Maísa; Ardenghi, Thiago M; Zanatta, Fabricio Batistin
2017-10-01
To compare the performance of partial-mouth periodontal examination (PMPE) protocols with different cut-off points to the full-mouth examination (FME) in the assessment of the prevalence and extent of gingival bleeding in adolescents. A cross-sectional study was conducted involving 12-year-old adolescents. Following a systematic two-stage cluster sampling process, 1134 individuals were evaluated. Different PMPE protocols were compared to the FME with six sites per tooth. Sensitivity, specificity, area under the ROC curve (AUC), intraclass correlation coefficient (ICC), relative and absolute biases and the inflation factor were assessed for each PMPE protocol with different cut-off points for the severity of gingival bleeding. The highest AUC values were found for the six-site two-diagonal quadrant (2-4) (0.97), six-site random half-mouth (0.95) and Community Periodontal Index (0.95) protocols. The assessment of three sites [mesiobuccal (MB), buccal (B) and distolingual (DL)] in two diagonal quadrants and the random half-mouth protocol had higher sensitivity and lower specificity than the same protocols with distobuccal (DB) sites. However, the use of DB sites led to better specificity and improved the balance between sensitivity and specificity, except for the two-diagonal quadrant (1-3) protocol. The ≥1 cut-off point led to the most discrepant results from the FME. Six-site two-diagonal quadrant (2-4) and random half-mouth assessments perform better in the evaluation of gingival bleeding in adolescents. However, when a faster protocol is needed, a two-diagonal quadrant assessment using only MB, B and DL sites can be used with no important loss of information. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Yu, Ji-Guo; Huang, Qing; Zhou, Xiao-Fang; Ding, Yi; Li, Jing; Xiang, Yi
2018-01-01
To evaluate and compare changes in retinal nerve fiber layer (RNFL) thickness in patients with the pseudoexfoliation syndrome (PXS) and healthy controls. Case-control studies were selected through an electronic search of the Cochrane Controlled Trials Register, PubMed, and Embase. Results were reviewed to ensure that the included studies met prespecified inclusion/exclusion criteria, and the quality of each study was assessed using the Newcastle-Ottawa Scale. All included studies measured average and 4-quadrant (temporal, superior, nasal, and inferior) RNFL thickness using optical coherence tomography (OCT). For the continuous outcomes, we calculated the weighted mean difference (WMD) and 95% confidence intervals (CIs). Eight case-control studies were included in this meta-analysis involving 225 eyes of PXS patients and 208 eyes of healthy controls in total. Statistical analysis revealed that the average RNFL thickness in PXS patients was significantly reduced compared to healthy controls (WMD = -6.91, 95% CI: -9.99 to -3.82, p < 0.0001). Additionally, differences in RNFL thickness in the superior quadrant (WMD = -10.68, 95% CI: -16.40 to -4.95, p = 0.0003), inferior quadrant (WMD = -8.20, 95% CI: -10.85 to -5.55, p < 0.00001), nasal quadrant (WMD = -3.05, 95% CI: -5.21 to -0.90, p = 0.005), and temporal quadrant (WMD = -6.39, 95% CI: -9.98 to -2.80, p = 0.0005) were all significant between the two groups. These results suggest that it is important to evaluate RNFL thickness and the optic nerve head through OCT in patients with PXS in order to determine early glaucomatous damage and start timely intervention prior to visual field loss. © 2017 S. Karger AG, Basel.
Davison, James A
2015-01-01
To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer.
Imaging of the iridocorneal angle with the RTVue spectral domain optical coherence tomography.
Perera, Shamira A; Ho, Ching Lin; Aung, Tin; Baskaran, Mani; Ho, Henrietta; Tun, Tin A; Lee, Tian Loon; Kumar, Rajesh S
2012-04-02
To determine the ability of the RTVue spectral domain optical coherence tomography (SDOCT) to image the anterior chamber angle (ACA). Consecutive subjects, recruited from glaucoma clinics, prospectively underwent ophthalmic evaluation including gonioscopy by an ophthalmologist and anterior chamber imaging with SDOCT, adapted with a corneal lens adapter (cornea anterior module-low magnification [CAM-L]) and anterior segment OCT (ASOCT), both performed by a technician. Two different ophthalmologists, masked to gonioscopy findings, assessed visualization of the scleral spur (SS), Schwalbe's line (SL), and trabecular meshwork (TM) by the two modalities. The ability to detect a closed angle was compared with gonioscopy. The average age (SD) of the 81 subjects enrolled was 64.1 (11.4) years; the majority were Chinese (91.4%) and female (61.7%). SDOCT images revealed the SS in 26.9% (56/324) of quadrants and the SL in 44.1% (143/324) of quadrants; in ASOCT images, the SS could be visualized in 69.1% (224/324) of quadrants (P < 0.0001), but the SL was undetectable. The TM was detected equally well (17.3%, P < 0.92) using either device. The angle status was gradable in only 41.7% images with SDOCT, compared with 71.3% of ASOCT images (P < 0.0001). ACA was classified as closed in 19.3% of quadrants (26/135) with SDOCT images and in 44.2% (102/231) with ASOCT images compared with 37.7% (122/324) on gonioscopy. When analyzing the horizontal quadrants only, both modalities agreed well with gonioscopy, 0.75 and 0.74, respectively (AC1 statistics). The RTVue SDOCT allowed visualization of SL, TM, and SS. However, these landmarks were not detected in a large percentage of images.
Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure
Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S
2012-01-01
Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393
NASA Astrophysics Data System (ADS)
Gavrilov, Milivoj B.; Marković, Slobodan B.; Schaetzl, Randall J.; Tošić, Ivana; Zeeden, Christian; Obreht, Igor; Sipos, György; Ruman, Albert; Putniković, Suzana; Emunds, Kathrin; Perić, Zoran; Hambach, Ulrich; Lehmkuhl, Frank
2018-04-01
This study utilizes four different methodological approaches to examine the prevailing surface winds and their associated aeolian processes in Northern Serbia, focusing on the southeastern part of the Carpathian Basin. We utilized wind and atmospheric pressure data from 1939-2014 and 1960-2010 for the climatological analyses. Geomorphological data and numerical simulations were used to estimate prevailing paleowind systems. Northern Serbia is currently dominated by surface winds coming from the fourth (270°-360°) and second (90°-180°) quadrants, with frequencies of ca. 116 and 105 days/year, respectively. Comparable frequencies within Banatska Peščara are 115 and 129 days/year, respectively. Crestal orientations of the vast majority of the ≈1300 parabolic dunes here suggest that they have formed from winds derived from the second quadrant, indicating formation during the early Holocene. The remaining dunes, of the transverse type, have orientations aligned to the third quadrant. Grain size analysis of loess deposits near Banatska Peščara points to deposition driven by southeasterly winds, probably during the period between the Last Glacial Maximum (LGM) and the early Holocene. Modern wind measurements and geomorphological data showed that the prevailing winds in the recent and past periods were from the same quadrant, in and around Banatska Peščara. These results were confirmed with an explicit numerical simulation that modelled prevailing winds from the second quadrant during the LGM. Thus, the various geomorphologic and climatic data analyzed in this study show that the general air circulation patterns in the recent period are not dissimilar to those operative during the LGM.
Chen, Ling; Zhang, Xiongze; Wen, Feng
2018-06-01
To determine whether venous beading (VB) in two or more quadrants is an appropriate grading criterion for severe nonproliferative diabetic retinopathy (NPDR). A hospital-based, retrospective, cross-sectional study. A total of 806 patients admitted with diabetic retinopathy (DR) from January 2014 to April 2017 were included in this study. DR severity was graded by the international grading criterion. The status of VB, intraretinal microvascular abnormalities (IRMA), capillary nonperfusion, arteriovenous nicking, and diabetic macular edema was evaluated based on fundus fluorescein angiography. The prevalence of VB in eyes with proliferative diabetic retinopathy (PDR), severe NPDR, and moderate NPDR was 41.3% (327/791), 5.9% (31/526), and 0% (0/295), respectively (p < 0.001). Moreover, the proportion of VB in two or more quadrants was even lower (27.1% for PDR and 2.1% for severe NPDR, p < 0.001), and among the total of 225 eyes with VB in two or more quadrants, 214 eyes (95.1%) were graded as PDR. Furthermore, VB formation was significantly correlated with capillary nonperfusion, duration of diabetes (both p < 0.001), and smoking (p < 0.05). After adjusting for age, sex, and other possible factors, VB (OR = 7.479, p < 0.001) and IRMA (OR = 2.433, p < 0.001) were determined as independent risk factors for developing PDR. Our study suggested that VB in two or more quadrants might not be a sensitive grading criterion for severe NPDR among a Chinese population with type 2 diabetes. Nevertheless, VB has a great specificity to define an advanced form of DR.
ERIC Educational Resources Information Center
Lockwood, Nicholas S.
2011-01-01
Geographically dispersed teams rely on information and communication technologies (ICTs) to communicate and collaborate. Three ICTs that have received attention are audio conferencing (AC), video conferencing (VC), and, recently, 3D virtual environments (3D VEs). These ICTs offer modes of communication that differ primarily in the number and type…
ERIC Educational Resources Information Center
Mitchell, Peter; Parsons, Sarah; Leonard, Anne
2007-01-01
Six teenagers with Autistic Spectrum Disorders (ASDs) experienced a Virtual Environment (VE) of a cafe. They also watched three sets of videos of real cafe and buses and judged where they would sit and explained why. Half of the participants received their VE experience between the first and second sets of videos, and half experienced it between…
Minor psychiatric disorders among nurses university faculties.
Tavares, Juliana Petri; Beck, Carmem Lúcia Colomé; Magnago, Tânia Solange Bosi de Souza; Zanini, Roselaine Ruviaro; Lautert, Liana
2012-01-01
This cross-sectional study addresses 130 nursing faculty members in federal universities from Rio Grande do Sul, Brazil. It investigated the psychological demands and decision latitude (the Demand-Control Model by Karasek) and their association with Minor Psychological Disorders (MPDs). The Brazilian versions of the Self-Report-Questionnaire-20 and the Job Stress Scale were used. MPDs were prevalent in 20% of the studied individuals. After adjusting for potential confounders, the chances of participants presenting mental disorders were higher in the quadrant 'active strain jobs' (OR=14.23, 95% CI 1.55 to 130.73), followed by the 'high strain jobs' quadrant (OR=10.05, 95% CI 1.23 to 82.44), compared to nursing professors classified in the 'low strain jobs' quadrant. We conclude that high psychological demands and low control over work can cause disorders in nursing professors, among them, MPDs.
First saccadic eye movement reveals persistent attentional guidance by implicit learning
Jiang, Yuhong V.; Won, Bo-Yeong; Swallow, Khena M.
2014-01-01
Implicit learning about where a visual search target is likely to appear often speeds up search. However, whether implicit learning guides spatial attention or affects post-search decisional processes remains controversial. Using eye tracking, this study provides compelling evidence that implicit learning guides attention. In a training phase, participants often found the target in a high-frequency, “rich” quadrant of the display. When subsequently tested in a phase during which the target was randomly located, participants were twice as likely to direct the first saccadic eye movement to the previously rich quadrant than to any of the sparse quadrants. The attentional bias persisted for nearly 200 trials after training and was unabated by explicit instructions to distribute attention evenly. We propose that implicit learning guides spatial attention but in a qualitatively different manner than goal-driven attention. PMID:24512610
Peruzzi, Agnese; Zarbo, Ignazio Roberto; Cereatti, Andrea; Della Croce, Ugo; Mirelman, Anat
2017-07-01
In this single blind randomized controlled trial, we examined the effect of a virtual reality-based training on gait of people with multiple sclerosis. Twenty-five individuals with multiple sclerosis with mild to moderate disability were randomly assigned to either the control group (n = 11) or the experimental group (n = 14). The subjects in the control group received treadmill training. Subjects in the experimental group received virtual reality based treadmill training. Clinical measures and gait parameters were evaluated. Subjects in both the groups significantly improved the walking endurance and speed, cadence and stride length, lower limb joint ranges of motion and powers, during single and dual task gait. Moreover, subjects in the experimental group also improved balance, as indicated by the results of the clinical motor tests (p < 0.05). Between-group comparisons revealed that the experimental group improved significantly more than control group in hip range of motion and hip generated power at terminal stance at post-training. Our results support the perceived benefits of training programs that incorporate virtual reality to improve gait measures in individuals with multiple sclerosis. Implication of rehabilitation Gait deficits are common in multiple sclerosis (85%) and worsen during dual task activities. Intensive and progressive treadmill training, with and without virtual reality, is effective on dual task gait in persons with multiple sclerosis. Virtual reality-based treadmill training requiring obstacle negotiation increases the range of motion and the power generated at the hip, consequently allowing longer stride length and, consequently, higher gait speed.
Transforming Norwegian Special Operation Forces
2006-06-01
Justice and Police. This pertains to the Coast Guard maintaining 146 Ole M. Rapp, "Får Europas Beste Marine [the Best Navy in Europe]," Aftenposten...service affiliation. Both units collectively represent capabilities within quadrant 1 and 2 of Figure 15. This is the flexibility NORSOF is assumed...reference to SOF’s domain. However, if indirect action capabilities are required or desired within both quadrants 3 and 4, domain matters. The
Suppression of the Near Wall Burst Process of a Fully Developed Turbulent Pipe Flow
1993-05-01
tunmel turbulent boundary layer a) velocity fluctuation skewness levels and b) velocity fluctuation kurtosis levels ...by the undisturbed total uv level and u*. a) quadrants I and 2 and b) quadrants 3 and 4 ...................... 105 5.20 Spanwise development of the uw...and radial velocity skewness levels . Normalization with ref. u". .............................. 111 xi 5.23 Spanwise development of profi!s of the
NASA Astrophysics Data System (ADS)
Huo, Chengyu; Huang, Xiaolin; Zhuang, Jianjun; Hou, Fengzhen; Ni, Huangjing; Ning, Xinbao
2013-09-01
The Poincaré plot is one of the most important approaches in human cardiac rhythm analysis. However, further investigations are still needed to concentrate on techniques that can characterize the dispersion of the points displayed by a Poincaré plot. Based on a modified Poincaré plot, we provide a novel measurement named distribution entropy (DE) and propose a quadrantal multi-scale distribution entropy analysis (QMDE) for the quantitative descriptions of the scatter distribution patterns in various regions and temporal scales. We apply this method to the heartbeat interval series derived from healthy subjects and congestive heart failure (CHF) sufferers, respectively, and find that the discriminations between them are most significant in the first quadrant, which implies significant impacts on vagal regulation brought about by CHF. We also investigate the day-night differences of young healthy people, and it is shown that the results present a clearly circadian rhythm, especially in the first quadrant. In addition, the multi-scale analysis indicates that the results of healthy subjects and CHF sufferers fluctuate in different trends with variation of the scale factor. The same phenomenon also appears in circadian rhythm investigations of young healthy subjects, which implies that the cardiac dynamic system is affected differently in various temporal scales by physiological or pathological factors.
CT enterography: Mannitol versus VoLumen.
Wong, Jessica; Moore, Helen; Roger, Mark; McKee, Chris
2016-10-01
Several different neutral oral contrast agents have been trialled in magnetic resonance and CT enterography (CTE). In the Auckland region, Mannitol 2.5% and VoLumen are both used in CTE. This study compares the performance of these two neutral oral contrast agents in CTE. Computed tomography enterography data were collected from 25 consecutive studies that used either Mannitol or VoLumen in 2014. All images were reviewed by three radiologists blinded to the type of oral contrast. Each quadrant was assessed for maximum distension, proportion of bowel loops distended, presence of inhomogeneous content and bowel wall visibility. Assessment also included whether the contrast agent reached the caecum and an overall subjective quality assessment. Patients were invited to answer a questionnaire regarding tolerability of the preparations. Mannitol achieves better wall visibility in the right upper quadrant, left upper quadrant and left lower quadrant (P < 0.01). Overall differences in study quality favours Mannitol (P < 0.01) with 48% of the Mannitol studies being considered excellent compared with 4% of the VoLumen studies. There was no difference in maximal distension or proportion of loops distended. Mannitol in CTE achieves studies of a better quality than and is a viable alternative to VoLumen. © 2016 The Royal Australian and New Zealand College of Radiologists.
Ushida, Yuka; Koshy, Geena; Kawashima, Yoko; Kiji, Makoto; Umeda, Makoto; Nitta, Hiroshi; Nagasawa, Toshiyuki; Ishikawa, Isao; Izumi, Yuichi
2008-11-01
This study aimed to compare the effect of single-visit full-mouth mechanical debridement (FMD) and quadrant-wise mechanical debridement (QMD) on the levels of serum interleukin (IL)-6, C-reactive protein (CRP) and soluble thrombomodulin. Thirty-six subjects with chronic periodontitis were randomly allocated to three groups: undergoing QMD, single-visit FMD with povidone iodine or with water. Serum IL-6 and soluble thrombomodulin were measured by enzyme-linked immunosorbent assay, and serum CRP was measured by the latex-enhanced nephelometric method. Serum IL-6 level increased significantly immediately after debridement in all the three groups, with this increase being greatest in the full-mouth groups. However, the increase in the full-mouth groups was not significantly higher than that of quadrant-wise group. In the quadrant-wise group, serum IL-6 level decreased significantly 1 month after debridement compared with baseline. Serum-soluble thrombomodulin decreased significantly in the full-mouth groups but not in the quadrant-wise group. Changes in CRP level were not significant at baseline or after debridement in all the three groups. FMD increased serum IL-6 and reduced serum-soluble thrombomodulin to a greater extent than QMD, suggesting that the former technique has stronger transient effects on systemic vascular endothelial functions than the latter.
Leung, W Keung; Duan, Yi Ran; Dong, Xiao Xiao; Yeung, Kim Wai Shadow; Zhou, Shuang Ying; Corbet, Esmonde F; Meng, Huan Xin
2016-01-01
Patients might refuse the offer of local anaesthesia (LA) administration prior to dental treatment. This study investigates subjective discomfort perception during non-surgical mechanical periodontal therapy delivered with or without LA. Sixty patients with mild to moderate chronic periodontitis and prior periodontal debridement experience were randomly enrolled in nonsurgical therapy of a quadrant with or without LA administration. Patients were free to comply or not with the allocated LA arrangement. Visual analogue scales (VAS) of discomfort perception at various stages of the treatment as well as overall satisfaction were recorded. Demographic, psychosocial and periodontal parameters were recorded. Thirty-one patients undergoing nonsurgical periodontal therapy not receiving (LA-) and 29 participants receiving LA (LA+) were studied. Compared to LA- patients, LA+ individuals perceived less discomfort during treatment and reported less dental anxiety (p<0.05). Lower overall treatment satisfaction was associated with prior unpleasant periodontal experience (p=0.047). Overall, debridement discomfort was associated with not receiving LA, noncompliance with the pain control regimen allocated, longer treatment duration, greater gingival inflammation and a higher percentage sites with probing pocket depths≥5 mm (p<0.05). Clinicians should be aware that patients who refuse LA can experience higher dental anxiety and therefore may require various pain control strategies for comfort during nonsurgical periodontal therapy, which, if not employed, can lead to less periodontal treatment satisfaction.
Yu, Mengmeng; Li, Yuehua; Li, Wenbin; Lu, Zhigang; Wei, Meng
2017-01-01
Objective To assess the feasibility of calcification characterization by coronary computed tomography angiography (CCTA) to predict the use of rotational atherectomy (RA) for coronary intervention of lesions with moderate to severe calcification. Materials and Methods Patients with calcified lesions treated by percutaneous coronary intervention (PCI) who underwent both CCTA and invasive coronary angiography were retrospectively included in this study. Calcification remodeling index was calculated as the ratio of the smallest vessel cross-sectional area of the lesion to the proximal reference luminal area. Other parameters such as calcium volume, regional Agatston score, calcification length, and involved calcium arc quadrant were also recorded. Results A total of 223 patients with 241 calcified lesions were finally included. Lesions with RA tended to have larger calcium volume, higher regional Agatston score, more involved calcium arc quadrants, and significantly smaller calcification remodeling index than lesions without RA. Receiver operating characteristic curve analysis revealed that the best cutoff value of calcification remodeling index was 0.84 (area under curve = 0.847, p < 0.001). Calcification remodeling index ≤ 0.84 was the strongest independent predictor (odds ratio: 251.47, p < 0.001) for using RA. Conclusion Calcification remodeling index was significantly correlated with the incidence of using RA to aid PCI. Calcification remodeling index ≤ 0.84 was the strongest independent predictor for using RA prior to stent implantation. PMID:28860893
NASA Astrophysics Data System (ADS)
Umemoto, Tomofumi; Minamidani, Tetsuhiro; Kuno, Nario; Fujita, Shinji; Matsuo, Mitsuhiro; Nishimura, Atsushi; Torii, Kazufumi; Tosaki, Tomoka; Kohno, Mikito; Kuriki, Mika; Tsuda, Yuya; Hirota, Akihiko; Ohashi, Satoshi; Yamagishi, Mitsuyoshi; Handa, Toshihiro; Nakanishi, Hiroyuki; Omodaka, Toshihiro; Koide, Nagito; Matsumoto, Naoko; Onishi, Toshikazu; Tokuda, Kazuki; Seta, Masumichi; Kobayashi, Yukinori; Tachihara, Kengo; Sano, Hidetoshi; Hattori, Yusuke; Onodera, Sachiko; Oasa, Yumiko; Kamegai, Kazuhisa; Tsuboi, Masato; Sofue, Yoshiaki; Higuchi, Aya E.; Chibueze, James O.; Mizuno, Norikazu; Honma, Mareki; Muller, Erik; Inoue, Tsuyoshi; Morokuma-Matsui, Kana; Shinnaga, Hiroko; Ozawa, Takeaki; Takahashi, Ryo; Yoshiike, Satoshi; Costes, Jean; Kuwahara, Sho
2017-10-01
The FUGIN project is one of legacy projects using a new multi-beam FOREST (four-beam receiver system on the 45 m telescope). This project aims to simultaneously investigate the distribution, kinematics, and physical properties of both diffuse and dense molecular gases in the Galaxy by observing 12CO, 13CO, and C18O J = 1-0 lines simultaneously. Mapping regions are parts of the first quadrant (10° ≤ l ≤ 50°, |b| ≤ 1°) and the third quadrant (198° ≤ l ≤ 236°, |b| ≤ 1°) of the Galaxy, where spiral arms, bar structure, and the molecular gas ring are included. This survey achieves the highest angular resolution to date (˜20″) for the Galactic plane survey in the CO J = 1-0 lines, which makes it possible to find dense clumps located farther away than the previous surveys. FUGIN will provide us an invaluable dataset for investigating the physics of the Galactic interstellar medium (ISM), particularly the evolution of interstellar gas covering galactic-scale structures to the internal structures of giant molecular clouds, such as small filaments/clumps/cores. We present an overview of the FUGIN project, the observation plan and initial results. These results reveal wide-field and detailed structures of molecular clouds, such as entangled filaments that have not been obvious in previous surveys, and large-scale kinematics of molecular gas, such as spiral arms.
Hurricane Hector in the Eastern Pacific
2006-08-17
Infrared, microwave, and visible/near-infrared images of Hurricane Hector in the eastern Pacific were created with data from the Atmospheric Infrared Sounder (AIRS) on NASA's Aqua satellite on August 17, 2006. The infrared AIRS image shows the temperature of the cloud tops or the surface of the Earth in cloud-free regions. The lowest temperatures (in purple) are associated with high, cold cloud tops that make up the top of the hurricane. The infrared signal does not penetrate through clouds. Where there are no clouds the AIRS instrument reads the infrared signal from the surface of the Earth, revealing warmer temperatures (red). At the time the data were taken from which these images were made, Hector is a well organized storm, with the strongest convection in the SE quadrant. The increasing vertical wind shear in the NW quadrant is appearing to have an effect. Maximum sustained winds are at 85 kt, gusts to 105 kt. Estimated minimum central pressure is 975 mbar. The microwave image is created from microwave radiation emitted by Earth's atmosphere and received by the instrument. It shows where the heaviest rainfall is taking place (in blue) in the storm. Blue areas outside of the storm where there are either some clouds or no clouds, indicate where the sea surface shines through. The "visible" image is created from data acquired by the visible light/near-infrared sensor on the AIRS instrument. http://photojournal.jpl.nasa.gov/catalog/PIA00507
LHCb experience with running jobs in virtual machines
NASA Astrophysics Data System (ADS)
McNab, A.; Stagni, F.; Luzzi, C.
2015-12-01
The LHCb experiment has been running production jobs in virtual machines since 2013 as part of its DIRAC-based infrastructure. We describe the architecture of these virtual machines and the steps taken to replicate the WLCG worker node environment expected by user and production jobs. This relies on the uCernVM system for providing root images for virtual machines. We use the CernVM-FS distributed filesystem to supply the root partition files, the LHCb software stack, and the bootstrapping scripts necessary to configure the virtual machines for us. Using this approach, we have been able to minimise the amount of contextualisation which must be provided by the virtual machine managers. We explain the process by which the virtual machine is able to receive payload jobs submitted to DIRAC by users and production managers, and how this differs from payloads executed within conventional DIRAC pilot jobs on batch queue based sites. We describe our operational experiences in running production on VM based sites managed using Vcycle/OpenStack, Vac, and HTCondor Vacuum. Finally we show how our use of these resources is monitored using Ganglia and DIRAC.
Can virtual science foster real skills? A study of inquiry skills in a virtual world
NASA Astrophysics Data System (ADS)
Dodds, Heather E.
Online education has grown into a part of the educational market answering the demand for learning at the learner's choice of time and place. Inquiry skills such as observing, questioning, collecting data, and devising fair experiments are an essential element of 21st-century online science coursework. Virtual immersive worlds such as Second Life are being used as new frontiers in science education. There have been few studies looking specifically at science education in virtual worlds that foster inquiry skills. This quantitative quasi-experimental nonrandomized control group pretest and posttest study explored what affect a virtual world experience had on inquiry skills as measured by the TIPS (Test of Integrated Process Skills) and TIPS II (Integrated Process Skills Test II) instruments. Participants between the ages of 18 and 65 were recruited from educator mailing lists and Second Life discussion boards and then sorted into the experimental group, which received instructions to utilize several displays in Mendelian genetics at the Genome Island location within Second Life, or the control group, which received text-based PDF documents of the same genetics course content. All participants, in the form of avatars, were experienced Second Life residents to reduce any novelty effect. This study found a greater increase in inquiry skills in the experimental group interacting using a virtual world to learn science content (0.90 points) than a control group that is presented only with online text-based content (0.87 points). Using a mixed between-within ANOVA (analysis of variance), with an alpha level of 0.05, there was no significant interaction between the control or experimental groups and inquiry skills, F (1, 58) = .783, p = .380, partial eta squared = .013, at the specified .05 alpha level suggesting no significant difference as a result of the virtual world exercise. However, there is not enough evidence to state that there was no effect because there was a greater increase in scores for the group that experienced a virtual world exercise. This study adds to the increasing body of knowledge about virtual worlds and inquiry skills, particularly with adult learners.
Using Virtual Reality in the Inference-Based Treatment of Compulsive Hoarding
St-Pierre-Delorme, Marie-Eve; O’Connor, Kieron
2016-01-01
The present study evaluated the efficacy of adding a virtual reality (VR) component to the treatment of compulsive hoarding (CH), following inference-based therapy (IBT). Participants were randomly assigned to either an experimental or a control condition. Seven participants received the experimental and seven received the control condition. Five sessions of 1 h were administered weekly. A significant difference indicated that the level of clutter in the bedroom tended to diminish more in the experimental group as compared to the control group F(2,24) = 2.28, p = 0.10. In addition, the results demonstrated that both groups were immersed and present in the environment. The results on posttreatment measures of CH (Saving Inventory revised, Saving Cognition Inventory and Clutter Image Rating scale) demonstrate the efficacy of IBT in terms of symptom reduction. Overall, these results suggest that the creation of a virtual environment may be effective in the treatment of CH by helping the compulsive hoarders take action over their clutter. PMID:27486574
An Overview of Virtual Acoustic Simulation of Aircraft Flyover Noise
NASA Technical Reports Server (NTRS)
Rizzi, Stephen A.
2013-01-01
Methods for testing human subject response to aircraft flyover noise have greatly advanced in recent years as a result of advances in simulation technology. Capabilities have been developed which now allow subjects to be immersed both visually and aurally in a three-dimensional, virtual environment. While suitable for displaying recorded aircraft noise, the true potential is found when synthesizing aircraft flyover noise because it allows the flexibility and freedom to study sounds from aircraft not yet flown. A virtual acoustic simulation method is described which is built upon prediction-based source noise synthesis, engineering-based propagation modeling, and empirically-based receiver modeling. This source-path-receiver paradigm allows complete control over all aspects of flyover auralization. With this capability, it is now possible to assess human response to flyover noise by systematically evaluating source noise reductions within the context of a system level simulation. Examples of auralized flyover noise and movie clips representative of an immersive aircraft flyover environment are made in the presentation.
Ródenas, J; Zarza, I; Burgos, M C; Felipe, A; Sánchez-Mayoral, M L
2004-01-01
Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed.
ERIC Educational Resources Information Center
Maidana, Nora L.; da Fonseca, Monaliza; Barros, Suelen F.; Vanin, Vito R.
2016-01-01
The Virtual Laboratory was created as a complementary educational activity, with the aim of working abstract concepts from an experimental point of view. In this work, the motion of a ring rolling and slipping in front of a grid printed panel was recorded. The frames separated from this video received a time code, and the resulting set of images…
ERIC Educational Resources Information Center
Hautala, Jarkko; Baker, Doris Luft; Keurulainen, Aleksi; Ronimus, Miia; Richardson, Ulla; Cole, Ronald
2018-01-01
The purpose of this pilot study with a within-subject design was to gain a deeper understanding about the promise and restrictions of a virtual tutoring system designed to teach science to first grade students in Finland. Participants were 61 students who received six tutoring science sessions of approximately 20 min each. Sessions consisted of a…
ERIC Educational Resources Information Center
Caeyenberghs, Karen; Wilson, Peter H.; van Roon, Dominique; Swinnen, Stephan P.; Smits-Engelsman, Bouwien C. M.
2009-01-01
Motor imagery (MI) has become a principal focus of interest in studies on brain and behavior. However, changes in MI across development have received virtually no attention so far. In the present study, children (N = 112, 6 to 16 years old) performed a new, computerized Virtual Radial Fitts Task (VRFT) to determine their MI ability as well as the…
Development of a teledermatopathology consultation system using virtual slides
2012-01-01
Background An online consultation system using virtual slides (whole slide images; WSI) has been developed for pathological diagnosis, and could help compensate for the shortage of pathologists, especially in the field of dermatopathology and in other fields dealing with difficult cases. This study focused on the performance and future potential of the system. Method In our system, histological specimens on slide glasses are digitalized by a virtual slide instrument, converted into web data, and up-loaded to an open server. Using our own purpose-built online system, we then input patient details such as age, gender, affected region, clinical data, past history and other related items. We next select up to ten consultants. Finally we send an e-mail to all consultants simultaneously through a single command. The consultant receives an e-mail containing an ID and password which is used to access the open server and inspect the images and other data associated with the case. The consultant makes a diagnosis, which is sent to us along with comments. Because this was a pilot study, we also conducted several questionnaires with consultants concerning the quality of images, operability, usability, and other issues. Results We solicited consultations for 36 cases, including cases of tumor, and involving one to eight consultants in the field of dermatopathology. No problems were noted concerning the images or the functioning of the system on the sender or receiver sides. The quickest diagnosis was received only 18 minutes after sending our data. This is much faster than in conventional consultation using glass slides. There were no major problems relating to the diagnosis, although there were some minor differences of opinion between consultants. The results of questionnaires answered by many consultants confirmed the usability of this system for pathological consultation. (16 out of 23 consultants.) Conclusion We have developed a novel teledermatopathological consultation system using virtual slides, and investigated the usefulness of the system. The results demonstrate that our system can be a useful tool for international medical work, and we anticipate its wider application in the future. Virtual slides The virtual slides for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1902376044831574 PMID:23237667
Optimizing Performance of a Microwave Salinity Mapper: STARRS L-Band Radiometer Enhancements
2007-05-04
Contribution Number NRL/JA/ setts at Amherst, along with Quadrant Engineering Inc. 7330-05-5313. (now ProSensing Inc.) and funding from the National...Thus, sampling schemes development of STARRS by Quadrant Engineering can be optimized for particular applications. STARRS began under Naval Research...performance to be optimized. As we show later, a draw- ture, computed as the mean temperature from four back of this approach not found in analog
Photocopy of aerial photograph, Pacific Air Industries, Flight 123V, June ...
Photocopy of aerial photograph, Pacific Air Industries, Flight 123V, June 29, 1960 (University of California, Santa Barbara, Map and Imagery Collection) PORTION OF IRVINE RANCH SHOWING SITE CA-2275-A IN LOWER LEFT QUADRANT AND SITE CA-2275-B IN UPPER RIGHT QUADRANT (see separate photograph index for 2275-B) - Irvine Ranch Agricultural Headquarters, Carillo Tenant House, Southwest of Intersection of San Diego & Santa Ana Freeways, Irvine, Orange County, CA
[Generalization of the Lotka-Volterra equation].
Nazarenko, V G
1976-01-01
A complete qualitative study of Lotka--Volterra model with cooperative interactions in the system predator-prey is carried out. The model is as follows: (see abstract). The character of all possible stationary states is investigated in the first quadrant of the phase plane of the model variables depending on the system parameters. It is shown that for the generalized model considered unstable and stable limit cycles only of the infinite amplitude are possible in the first quadrant.
NASA Technical Reports Server (NTRS)
Tsurutani, B. T.; Smith, E. J.; Jones, D. E.; Lepping, R. P.; Sibeck, D. G.
1984-01-01
The relationships between the Solar Magnetospheric (SM) y-component of the interplanetary magnetic field (IMF) and the lobe and plasmasheet magnetic fields have been studied for the two ISEE-3 deep tail passes. It is found that for positive sector IMFs, 13 percent of the interplanetary magnetic field penetrates into the aberrated north-dawn and south-dusk lobe quadrants, and about the same amount in the north-dusk and south-dawn lobe quadrants for negative sector IMFs. For the above cases, field penetration is significantly less for opposite polarity IMFs. The former results are generally consistent with open magnetospheric models, but the latter (the lack of response in certain quadrants) are unexplained by theory at this time. If the magnitude of the plasmasheet B(y) fields are related to plasma pressure anisotropies, very small anisotropies of about 1.01 are expected.
NASA Astrophysics Data System (ADS)
Kurukuri, Srihari; Worswick, Michael J.
2013-12-01
An alternative approach is proposed to utilize symmetric yield functions for modeling the tension-compression asymmetry commonly observed in hcp materials. In this work, the strength differential (SD) effect is modeled by choosing separate symmetric plane stress yield functions (for example, Barlat Yld 2000-2d) for the tension i.e., in the first quadrant of principal stress space, and compression i.e., third quadrant of principal stress space. In the second and fourth quadrants, the yield locus is constructed by adopting interpolating functions between uniaxial tensile and compressive stress states. In this work, different interpolating functions are chosen and the predictive capability of each approach is discussed. The main advantage of this proposed approach is that the yield locus parameters are deterministic and relatively easy to identify when compared to the Cazacu family of yield functions commonly used for modeling SD effect observed in hcp materials.
Streamwise evolution of statistical events and the triple correlation in a model wind turbine array
NASA Astrophysics Data System (ADS)
Viestenz, Kyle; Cal, Raúl Bayoán
2013-11-01
Hot-wire anemometry data, obtained from a wind tunnel experiment containing a 3 × 3 wind turbine array, are used to conditionally average the Reynolds stresses. Nine profiles at the centerline behind the array are analyzed to characterize the turbulent velocity statistics of the wake flow. Quadrant analysis yields statistical events occurring in the wake of the wind farm, where quadrants 2 and 4 produce ejections and sweeps, respectively. A balance between these quadrants is expressed via the ΔSo parameter, which attains a maximum value at the bottom tip and changes sign near the top tip of the rotor. These are then associated to the triple correlation term present in the turbulent kinetic energy equation of the fluctuations. The development of these various quantities is assessed in light of wake remediation, energy transport and possess significance in closure models. National Science Foundation: ECCS-1032647.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aeloiza, Eddy C.; Burgos, Rolando P.
A step-down AC/AC converter for use in an electric distribution system includes at least one chopper circuit for each one of a plurality of phases of the AC power, each chopper circuit including a four-quadrant switch coupled in series between primary and secondary sides of the chopper circuit and a current-bidirectional two-quadrant switch coupled between the secondary side of the chopper circuit and a common node. Each current-bidirectional two-quadrant switch is oriented in the same direction, with respect to the secondary side of the corresponding chopper circuit and the common node. The converter further includes a control circuit configured tomore » pulse-width-modulate control inputs of the switches, to convert a first multiphase AC voltage at the primary sides of the chopper circuits to a second multiphase AC voltage at the secondary sides of the chopper circuits, the second multiphase AC voltage being lower in voltage than the first multiphase AC voltage.« less
Saugel, Bernd; Grothe, Oliver; Wagner, Julia Y
2015-08-01
When comparing 2 technologies for measuring hemodynamic parameters with regard to their ability to track changes, 2 graphical tools are omnipresent in the literature: the 4-quadrant plot and the polar plot recently proposed by Critchley et al. The polar plot is thought to be the more advanced statistical tool, but care should be taken when it comes to its interpretation. The polar plot excludes possibly important measurements from the data. The polar plot transforms the data nonlinearily, which may prevent it from being seen clearly. In this article, we compare the 4-quadrant and the polar plot in detail and thoroughly describe advantages and limitations of each. We also discuss pitfalls concerning the methods to prepare the researcher for the sound use of both methods. Finally, we briefly revisit the Bland-Altman plot for the use in this context.
Delmore, James E.
1987-01-01
A method and apparatus for providing a negative ion source accelerates electrons away from a hot filament electron emitter into a region of crossed electric and magnetic fields arranged in a magnetron configuration. During a portion of the resulting cycloidal path, the electron velocity is reduced below its initial value. The electron accelerates as it leaves the surface at a rate of only slightly less than if there were no magnetic field, thereby preventing a charge buildup at the surface of the emitter. As the electron traverses the cycloid, it is decelerated during the second, third, and fourth quadrants, then reeccelerated as it approaches the end of the fourth quadrant to regain its original velocity. The minimum velocity occurs during the fourth quadrant, and corresponds to an electron temperature of 200.degree. to 500.degree. for the electric and magnetic fields commonly encountered in the ion sources of magnetic sector mass spectrometers. An ion source using the above-described thermalized electrons is also disclosed.
Roy, Basudev; Bera, Sudipta K; Banerjee, Ayan
2014-06-01
We describe a simple yet powerful technique of simultaneously measuring both translational and rotational motion of mesoscopic particles in optical tweezers by measuring the backscattered intensity on a quadrant photodiode (QPD). While the measurement of translational motion by taking the difference of the backscattered intensity incident on adjacent quadrants of a QPD is well known, we demonstrate that rotational motion can be measured very precisely by taking the difference between the diagonal quadrants. The latter measurement eliminates the translational component entirely and leads to a detection sensitivity of around 50 mdeg at S/N of 2 for angular motion of a driven microrod. The technique is also able to resolve the translational and rotational Brownian motion components of the microrod in an unperturbed trap and can be very useful in measuring translation-rotation coupling of micro-objects induced by hydrodynamic interactions.
Data communications in a parallel active messaging interface of a parallel computer
Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.
2014-09-02
Eager send data communications in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI composed of data communications endpoints that specify a client, a context, and a task, including receiving an eager send data communications instruction with transfer data disposed in a send buffer characterized by a read/write send buffer memory address in a read/write virtual address space of the origin endpoint; determining for the send buffer a read-only send buffer memory address in a read-only virtual address space, the read-only virtual address space shared by both the origin endpoint and the target endpoint, with all frames of physical memory mapped to pages of virtual memory in the read-only virtual address space; and communicating by the origin endpoint to the target endpoint an eager send message header that includes the read-only send buffer memory address.
Data communications in a parallel active messaging interface of a parallel computer
Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.
2014-09-16
Eager send data communications in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI composed of data communications endpoints that specify a client, a context, and a task, including receiving an eager send data communications instruction with transfer data disposed in a send buffer characterized by a read/write send buffer memory address in a read/write virtual address space of the origin endpoint; determining for the send buffer a read-only send buffer memory address in a read-only virtual address space, the read-only virtual address space shared by both the origin endpoint and the target endpoint, with all frames of physical memory mapped to pages of virtual memory in the read-only virtual address space; and communicating by the origin endpoint to the target endpoint an eager send message header that includes the read-only send buffer memory address.
Predicting Innovation Acceptance by Simulation in Virtual Environments (Theoretical Foundations)
NASA Astrophysics Data System (ADS)
León, Noel; Duran, Roberto; Aguayo, Humberto; Flores, Myrna
This paper extends the current development of a methodology for Computer Aided Innovation. It begins with a presentation of concepts related to the perceived capabilities of virtual environments in the Innovation Cycle. The main premise establishes that it is possible to predict the acceptance of a new product in a specific market, by releasing an early prototype in a virtual scenario to quantify its general reception and to receive early feedback from potential customers. The paper continues to focus this research on a synergistic extension of techniques that have their origins in optimization and innovation disciplines. TRIZ (Theory of Inventive Problem Solving), extends the generation of variants with Evolutionary Algorithms (EA) and finally to present the designer and the intended customer, creative and innovative alternatives. All of this developed on a virtual software interface (Virtual World). The work continues with a general description of the project as a step forward to improve the overall strategy.
Strandbygaard, Jeanett; Bjerrum, Flemming; Maagaard, Mathilde; Winkel, Per; Larsen, Christian Rifbjerg; Ringsted, Charlotte; Gluud, Christian; Grantcharov, Teodor; Ottesen, Bent; Sorensen, Jette Led
2013-05-01
To investigate the impact of instructor feedback versus no instructor feedback when training a complex operational task on a laparoscopic virtual reality simulator. : Simulators are now widely accepted as a training tool, but there is insufficient knowledge about how much feedback is necessary, which is useful for sustainable implementation. A randomized trial complying with CONSORT Statement. All participants had to reach a predefined proficiency level for a complex operational task on a virtual reality simulator. The intervention group received standardized instructor feedback a maximum of 3 times. The control group did not receive instructor feedback. Participants were senior medical students without prior laparoscopic experience (n = 99). Outcome measures were time, repetitions, and performance score to reach a predefined proficiency level. Furthermore, influence of sex and perception of own surgical skills were examined. Time (in minutes) and repetitions were reduced in the intervention group (162 vs 342 minutes; P < 0.005) and (29 vs 65 repetitions; P < 0.005). The control group achieved a higher performance score than the intervention group (57% vs 49%; P = 0.004). Men used less time (in minutes) than women (P = 0.037), but no sex difference was observed for repetitions (P = 0.20). Participants in the intervention group had higher self-perception regarding surgical skills after the trial (P = 0.011). Instructor feedback increases the efficiency when training a complex operational task on a virtual reality simulator; time and repetitions used to achieve a predefined proficiency level were significantly reduced in the group that received instructor feedback compared with the control group. NCT01497782.
Park, Yu-Hyung; Lee, Chi-Ho; Lee, Byoung-Hee
2013-01-01
This study is a single blind randomized controlled trial to determine the effect of virtual reality-based postural control training on the gait ability in patients with chronic stroke. Sixteen subjects were randomly assigned to either experimental group (VR, n= 8) or control group (CPT, n= 8). Subjects in both groups received conventional physical therapy for 60 min per day, five days per week during a period of four weeks. Subjects in the VR group received additional augmented reality-based training for 30 min per day, three days per week during a period of four weeks. The subjects were evaluated one week before and after participating in a four week training and follow-up at one month post-training. Data derived from the gait analyses included spatiotemporal gait parameters, 10 meters walking test (10 mWT). In the gait parameters, subjects in the VR group showed significant improvement, except for cadence at post-training and follow-up within the experimental group. However, no obvious significant improvement was observed within the control group. In between group comparisons, the experimental group (VR group) showed significantly greater improvement only in stride length compared with the control group (P< 0.05), however, no significant difference was observed in other gait parameters. In conclusion, we demonstrate significant improvement in gait ability in chronic stroke patients who received virtual reality based postural control training. These findings suggest that virtual reality (VR) postural control training using real-time information may be a useful approach for enhancement of gait ability in patients with chronic stroke.
Shiri, Shimon; Feintuch, Uri; Lorber-Haddad, Adi; Moreh, Elior; Twito, Dvora; Tuchner-Arieli, Maya; Meiner, Zeev
2012-01-01
To introduce the rationale of a novel virtual reality system based on self-face viewing and mirror visual feedback, and to examine its feasibility as a rehabilitation tool for poststroke patients. A novel motion capture virtual reality system integrating online self-face viewing and mirror visual feedback has been developed for stroke rehabilitation.The system allows the replacement of the impaired arm by a virtual arm. Upon making small movements of the paretic arm, patients view themselves virtually performing healthy full-range movements. A sample of 6 patients in the acute poststroke phase received the virtual reality treatment concomitantly with conservative rehabilitation treatment. Feasibility was assessed during 10 sessions for each participant. All participants succeeded in operating the system, demonstrating its feasibility in terms of adherence and improvement in task performance. Patients' performance within the virtual environment and a set of clinical-functional measures recorded before the virtual reality treatment, at 1 week, and after 3 months indicated neurological status and general functioning improvement. These preliminary results indicate that this newly developed virtual reality system is safe and feasible. Future randomized controlled studies are required to assess whether this system has beneficial effects in terms of enhancing upper limb function and quality of life in poststroke patients.
Alahmari, Khalid A; Sparto, Patrick J; Marchetti, Gregory F; Redfern, Mark S; Furman, Joseph M; Whitney, Susan L
2014-03-01
We examined outcomes in persons with vestibular disorders after receiving virtual reality based therapy (VRBT) or customized vestibular physical therapy (PT) as an intervention for habituation of dizziness symptoms. Twenty subjects with vestibular disorders received VRBT and 18 received PT. During the VRBT intervention, subjects walked on a treadmill within an immersive virtual grocery store environment, for six sessions approximately one week apart. The PT intervention consisted of gaze stabilization, standing balance and walking exercises individually tailored to each subject. Before, one week after, and at six months after the intervention, subjects completed self-report and balance performance measures. Before and after each VRBT session, subjects also reported symptoms of nausea, headache, dizziness, and visual blurring. In both groups, significant improvements were noted on the majority of self-report and performance measures one week after the intervention. Subjects maintained improvements on self report and performance measures at six months follow up. There were not between group differences. Nausea, headache, dizziness and visual blurring increased significantly during the VRBT sessions, but overall symptoms were reduced at the end of the six-week intervention. While this study did not find a difference in outcomes between PT and VRBT, the mechanism by which subjects with chronic dizziness demonstrated improvement in dizziness and balance function may be different.
Cuthbert, Jeffrey P; Staniszewski, Kristi; Hays, Kaitlin; Gerber, Don; Natale, Audrey; O'Dell, Denise
2014-01-01
To evaluate the feasibility and safety of utilizing a commercially available virtual reality gaming system as a treatment intervention for balance training. A randomized controlled trial in which assessment and analysis were blinded. An inpatient rehabilitation facility. Interventions included balance-based physical therapy using a Nintendo Wii, as monitored by a physical therapist, and receipt of one-on-one balance-based physical therapy using standard physical therapy modalities available for use in the therapy gym. Participants in the standard physical therapy group were found to have slightly higher enjoyment at mid-intervention, while those receiving the virtual reality-based balance intervention were found to have higher enjoyment at study completion. Both groups demonstrated improved static and dynamic balance over the course of the study, with no significant differences between groups. Correlational analyses suggest a relationship exists between Wii balance board game scores and BBS scores for measures taken beyond the baseline assessment. This study provides a modest level of evidence to support using commercially available VR gaming systems for the treatment of balance deficits in patients with a primary diagnosis of TBI receiving inpatient rehabilitation. Additional research of these types of interventions for the treatment of balance deficits is warranted.
Superior versus inferior Ahmed glaucoma valve implantation.
Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi
2009-02-01
To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5
Controlling Within-Field Sheep Movement Using Virtual Fencing.
Marini, Danila; Llewellyn, Rick; Belson, Sue; Lee, Caroline
2018-02-26
Virtual fencing has the potential to greatly improve livestock movement, grazing efficiency, and land management by farmers; however, relatively little work has been done to test the potential of virtual fencing with sheep. Commercial dog training equipment, comprising of a collar and GPS hand-held unit were used to implement a virtual fence in a commercial setting. Six, 5-6 year-old Merino wethers, which were naïve to virtual fencing were GPS tracked for their use of a paddock (80 × 20 m) throughout the experiment. The virtual fence was effective at preventing a small group of sheep from entering the exclusion zone. The probability of a sheep receiving an electrical stimulus following an audio cue was low (19%), and declined over the testing period. It took an average of eight interactions with the fence for an association to be made between the audio and stimulus cue, with all of the animals responding to the audio alone by the third day. Following the removal of the virtual fence, sheep were willing to cross the previous location of the virtual fence after 30 min of being in the paddock. This is an important aspect in the implementation of virtual fencing as a grazing management tool and further enforces that the sheep in this study were able to associate the audio with the virtual fence and not the physical location itself.
The Jordan River: Source of Life and Source of Conflict
2010-03-01
potential conflict begin almost where the Jordan River itself begins – at it headwaters in Lebanon, in the northwest quadrant of the Jordan River...essentially focuses attention on the tension between Israel and Syria, in the northeast quadrant of the Jordan River basin. This is an area where mainly...34 Foreign Policy, no. 54 (1984): 3-26. 23 Arnold Hottinger, “Wasser als Konfliktstoff: Eine Existenzfrage für Staaten des Nahen Ostens,” Europa
1975-06-01
approximately four . Presently referred to as the hypermixing nozzle (See Figure 37). d. Alternating exit nozzle - same as c, but the elemental aspect ratio...UL 0 Reynolds number, defined as R . In addition, due to the double symmetry about the y and z axes, the analysis will treat only one quadrant of the...in the duct of diffuser. Then from the conservation of mass A~x Atx) where A(x) g(x) tl(x) is the streamwise area distribution in one quadrant
Magnetic storm inflation in the evening sector.
NASA Technical Reports Server (NTRS)
Cahill, L. J., Jr.
1973-01-01
Analysis of the different behavior of a double magnetic disturbance in November 1971, as observed by Explorer 45, and in December 1971, as shown by ground level magnetic observations. The time sequence of magnetic storm inflation in the evening quadrant of the magnetosphere, as determined by both series of observations, is used as the criterion of the analysis. Particular attention is given to the various phases of proton penetration into the evening quadrant of the magnetosphere during the magnetic disturbance.
Dynamic and Static Shape Test/Analysis Correlation of a 10 Meter Quadrant Solar Sail
NASA Technical Reports Server (NTRS)
Taleghani, Barmac K.; Lively, Peter S.; Gaspar, James L.; Murphy, David M.; Trautt, Thomas A.
2005-01-01
This paper describes finite element analyses and correlation studies to predict deformations and vibration modes/frequencies of a 10-meter quadrant solar sail system. Thin film membranes and booms were analyzed at the component and system-level. The objective was to verify the design and structural responses of the sail system and to mature solar sail technology to a TRL 5. The focus of this paper is in test/analysis correlation.
Situational leadership: a management system to increase staff satisfaction.
Zurlinden, J; Bongard, B; Magafas, M
1990-01-01
Using the principles of Situational Leadership, nurse managers can deal with people and situations effectively and flexibly--helping to retain nurses on their units. Based on the manager's assessment of the nurse's ability and willingness for a specific task, each nurse falls into one of four readiness quadrants. Each quadrant predicts a corresponding leadership style: telling, selling, participating, or delegating. Nurse managers need to use different combinations of task behavior and relationship behavior for each corresponding leadership style.
Clinical effect of reducing curing times with high-intensity LED lights
Ward, Justin D.; Wolf, Bethany J.; Leite, Luis P.; Zhou, Jing
2016-01-01
Objective To evaluate the clinical performance of brackets cured with a high-intensity, light-emitting diode (LED) with a shorter curing time. Materials and Methods Thirty-four patients and a total of 680 brackets were examined using a randomized split-mouth design. The maxillary right and mandibular left quadrants were cured for 6 seconds with a high-intensity LED light (3200 mW/cm2) and the maxillary left and mandibular right quadrants were cured for 20 seconds with a standard-intensity LED light (1200 mW/cm2). Alternating patients had the quadrants inverted for the curing protocol. The number and date of each first-time bracket failure was recorded from 199 to 585 days posttreatment. Results The bracket failure rate was 1.18% for both curing methods. The proportion of bracket failure was not significantly different between curing methods (P = 1.000), genders (P = 1.000), jaws (P = .725), sides (P = .725), or quadrants (P = .547). Posterior teeth exhibited a greater proportion of failures (2.21%) relative to anterior teeth (0.49%), although the difference was not statistically significant (P = .065). Conclusions No difference was found in bond failure rates between the two curing methods. Both methods showed bond failure rates low enough to be considered clinically sufficient. The high-intensity LED light used with a shorter curing time may be considered an advantage due to the reduced chair time. PMID:25760887
Pena, Roberta Ribas; Medeiros, Daniel de Castro; Guarnieri, Leonardo de Oliveira; Guerra, Julio Boriollo; Carvalho, Vinícius Rezende; Mendes, Eduardo Mazoni Andrade Marçal; Pereira, Grace Schenatto; Moraes, Márcio Flávio Dutra
2017-11-05
The brain oscillations may play a critical role in synchronizing neuronal assemblies in order to establish appropriate sensory-motor integration. In fact, studies have demonstrated phase-amplitude coupling of distinct oscillatory rhythms during cognitive processes. Here we investigated whether olfacto-hippocampal coupling occurs when mice are detecting familiar odors located in a spatially restricted area of a new context. The spatial olfactory task (SOT) was designed to expose mice to a new environment in which only one quadrant (target) contains odors provided by its own home-cage bedding. As predicted, mice showed a significant higher exploration preference to the target quadrant; which was impaired by olfactory epithelium lesion (ZnSO 4 ). Furthermore, mice were able to discriminate odors from a different cage and avoided the quadrant with predator odor 2,4,5-trimethylthiazoline (TMT), reinforcing the specificity of the SOT. The local field potential (LFP) analysis of non-lesioned mice revealed higher gamma activity (35-100Hz) in the main olfactory bulb (MOB) and a significant theta phase/gamma amplitude coupling between MOB and dorsal hippocampus, only during exploration of home-cage odors (i.e. in the target quadrant). Our results suggest that exploration of familiar odors in a new context involves dynamic coupling between the olfactory bulb and dorsal hippocampus. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Prevention of Severe Hypoglycemia-Induced Brain Damage and Cognitive Impairment with Verapamil.
Jackson, David A; Michael, Trevin; Vieira de Abreu, Adriana; Agrawal, Rahul; Bortolato, Marco; Fisher, Simon J
2018-05-03
People with insulin-treated diabetes are uniquely at risk for severe hypoglycemia-induced brain damage. Since calcium influx may mediate brain damage, we tested the hypothesis that the calcium channel blocker, verapamil, would significantly reduce brain damage and cognitive impairment caused by severe hypoglycemia. Ten-week-old Sprague-Dawley rats were randomly assigned to one of three treatments; 1) control hyperinsulinemic (200 mU.kg -1 min -1 ) euglycemic (80-100mg/dl) clamps (n=14), 2) hyperinsulinemic hypoglycemic (10-15mg/dl) clamps (n=16), or 3) hyperinsulinemic hypoglycemic clamps followed by a single treatment with verapamil (20mg/kg) (n=11). As compared to euglycemic controls, hypoglycemia markedly increased dead/dying neurons in the hippocampus and cortex, by 16-fold and 14-fold, respectively. Verapamil treatment strikingly decreased hypoglycemia-induced hippocampal and cortical damage, by 87% and 94%, respectively. Morris Water Maze probe trial results demonstrated that hypoglycemia induced a retention, but not encoding, memory deficit (noted by both abolished target quadrant preference and reduced target quadrant time). Verapamil treatment significantly rescued spatial memory as noted by restoration of target quadrant preference and target quadrant time. In summary, a one-time treatment with verapamil following severe hypoglycemia prevented neural damage and memory impairment caused by severe hypoglycemia. For people with insulin treated diabetes, verapamil may be a useful drug to prevent hypoglycemia-induced brain damage. © 2018 by the American Diabetes Association.
Tang, Tjun Y; Howarth, Simon P S; Miller, Sam R; Graves, Martin J; U‐King‐Im, Jean‐Marie; Trivedi, Rikin A; Li, Zhi Yong; Walsh, Stewart R; Brown, Andrew P; Kirkpatrick, Peter J; Gaunt, Michael E; Gillard, Jonathan H
2007-01-01
Background Inflammation is a recognised risk factor for the vulnerable atherosclerotic plaque. The aim of this study was to explore whether there is a difference in the degree of magnetic resonance (MR) defined inflammation using ultra small superparamagnetic iron oxide (USPIO) particles within carotid atheroma in completely asymptomatic individuals and the asymptomatic carotid stenosis contralateral to the symptomatic side. Methods 20 symptomatic patients with contralateral disease and 20 completely asymptomatic patients underwent multi‐sequence MR imaging before and 36 h after USPIO infusion. Images were manually segmented into quadrants and signal change in each quadrant was calculated following USPIO administration. Mean signal change was compared across all quadrants in the two groups. Results The mean percentage of quadrants showing signal loss was 53% in the contralateral group compared with 31% in completely asymptomatic individuals (p = 0.025). The mean percentages showing enhancement were 44% and 65%, respectively (p = 0.024). The mean signal difference between the two groups was 8.6% (95% CI 1.6% to 15.6%; p = 0.017). Conclusions Truly asymptomatic plaques seem to demonstrate inflammation but not to the extent of the contralateral asymptomatic stenosis to the symptomatic side. Inflammatory activity may be a significant risk factor in asymptomatic disease. PMID:17578854
NASA Astrophysics Data System (ADS)
Krapukhina, Nina; Senchenko, Roman; Kamenov, Nikolay
2017-12-01
Road safety and driving in dense traffic flows poses some challenges in receiving information about surrounding moving object, some of which can be in the vehicle's blind spot. This work suggests an approach to virtual monitoring of the objects in a current road scene via a system with a multitude of cooperating smart vehicles exchanging information. It also describes the intellectual agent model, and provides methods and algorithms of identifying and evaluating various characteristics of moving objects in video flow. Authors also suggest ways for integrating the information from the technical vision system into the model with further expansion of virtual monitoring for the system's objects. Implementation of this approach can help to expand the virtual field of view for a technical vision system.
2014-01-01
Background The importance of using technologies such as e-learning in different disciplines is discussed in the literature. Researchers have measured the effectiveness of e-learning in a number of fields. Considering the lack of research on the effectiveness of online learning in dental education particularly in Iran, the advantages of these learning methods and the positive university atmosphere regarding the use of online learning. This study, therefore, aims to compare the effects of two methods of teaching (virtual versus traditional) on student learning. Methods This post-test only design study approached 40, fifth year dental students of Shiraz University of Medical Sciences. From this group, 35 students agreed to participate. These students were randomly allocated into two groups, experimental (virtual learning) and comparison (traditional learning). To ensure similarity between groups, we compared GPAs of all participants by the Mann–Whitney U test (P > 0.05). The experimental group received a virtual learning environment courseware package specifically designed for this study, whereas the control group received the same module structured in a traditional lecture form. The virtual learning environment consisted of online and offline materials. Two identical valid, reliable post-tests that consisted of 40 multiple choice questions (MCQs) and 4 essay questions were administered immediately (15 min) after the last session and two months later to assess for knowledge retention. Data were analyzed by SPSS version 20. Results A comparison of the mean knowledge score of both groups showed that virtual learning was more effective than traditional learning (effect size = 0.69). Conclusion The newly designed virtual learning package is feasible and will result in more effective learning in comparison with lecture-based training. However further studies are needed to generalize the findings of this study. PMID:24597923
The Quantum Workings of the Rotating 64-Grid Genetic Code
Castro-Chavez, Fernando
2011-01-01
In this article, the pattern learned from the classic or conventional rotating circular genetic code is transferred to a 64-grid model. In this non-static representation, the codons for the same amino acid within each quadrant could be exchanged, wobbling or rotating in a quantic way similar to the electrons within an atomic orbit. Represented in this 64-grid format are the three rules of variation encompassing 4, 2, or 1 quadrant, respectively: 1) same position in four quadrants for the essential hydrophobic amino acids that have U at the center, 2) same or contiguous position for the same or related amino acids in two quadrants, and 3) equivalent amino acids within one quadrant. Also represented is the mathematical balance of the odd and even codons, and the most used codons per amino acid in humans compared to one diametrically opposed organism: the plant Arabidopsis thaliana, a comparison that depicts the difference in third nucleotide preferences: a C/U exchange for 11 amino acids, a G/A and a G/U exchange for 2 amino acids, respectively, and a C/A exchange for one amino acid; by studying these codon usage preferences per amino acid we present our two hypotheses: 1) A slower translation in vertebrates and 2) a faster translation in invertebrates, possibly due to the aqueous environments where they live. These codon usage preferences may also be able to determine genomic compatibility by comparing individual mRNAs and their functional third dimensional structure, transport and translation within cells and organisms. These observations are aimed to the design of bioinformatics computational tools to compare human genomes and to determine the exchange between compatible codons and amino acids, to preserve and/or to bring back extinct biodiversity, and for the early detection of incompatible changes that lead to genetic diseases. PMID:22308074
The effect of using different regions of interest on local and mean skin temperature.
Maniar, Nirav; Bach, Aaron J E; Stewart, Ian B; Costello, Joseph T
2015-01-01
The dynamic nature of tissue temperature and the subcutaneous properties, such as blood flow, fatness, and metabolic rate, leads to variation in local skin temperature. Therefore, we investigated the effects of using multiple regions of interest when calculating weighted mean skin temperature from four local sites. Twenty-six healthy males completed a single trial in a thermonetural laboratory (mean ± SD): 24.0 (1.2)°C; 56 (8%) relative humidity; <0.1 m/s air speed). Mean skin temperature was calculated from four local sites (neck, scapula, hand and shin) in accordance with International Standards using digital infrared thermography. A 50 mm × 50 mm, defined by strips of aluminium tape, created six unique regions of interest, top left quadrant, top right quadrant, bottom left quadrant, bottom right quadrant, centre quadrant and the entire region of interest, at each of the local sites. The largest potential error in weighted mean skin temperature was calculated using a combination of a) the coolest and b) the warmest regions of interest at each of the local sites. Significant differences between the six regions interest were observed at the neck (P<0.01), scapula (P<0.001) and shin (P<0.05); but not at the hand (P = 0.482). The largest difference (± SEM) at each site was as follows: neck 0.2 (0.1)°C; scapula 0.2 (0.0)°C; shin 0.1 (0.0)°C and hand 0.1 (0.1)°C. The largest potential error (mean ± SD) in weighted mean skin temperature was 0.4 (0.1)°C (P<0.001) and the associated 95% limits of agreement for these differences was 0.2-0.5 °C. Although we observed differences in local and mean skin temperature based on the region of interest employed, these differences were minimal and are not considered physiologically meaningful. Copyright © 2015 Elsevier Ltd. All rights reserved.
Davison, James A
2015-01-01
Purpose To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. Patients and methods A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Results Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. Conclusion A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer. PMID:26355695
Uveal effusion following acute primary angle-closure: a retrospective case series
Yang, Jian-Gang; Li, Jian-Jun; Tian, Hua; Li, Yan-Hong; Gong, Yu-Jing; Su, An-Le; He, Na
2017-01-01
AIM To evaluate the morphological changes in anterior segment in Chinese patients with uveal effusion (UE) after the attack of acute primary angle-closure (APAC) using ultrasound biomicroscopy (UBM), and to assess the clinical course and prognosis of the disease. METHODS In a retrospective case series, 26 eyes in 26 consecutive patients diagnosed with UE after the treatment of intraocular pressure (IOP)-lowering medication for the attack of APAC were enrolled. The unaffected fellow eyes served as controls. The morphological changes were observed by ultrasonography, slit lamp microscopy and gonioscopy. UBM was used to assess the degree and extent of effusion based on the analysis of parameters associated with UE. RESULTS The mean IOP was 9.2 (SD 2.1) mm Hg at the diagnosis of UE after IOP-lowering medication, while 14.1 (SD, 2.6) mm Hg in the fellow eyes (P=0.000). The anterior chamber depth (ACD) (P=0.000), angle opening distance at 500 µm (AOD500) (P<0.01) and anterior chamber angle (ACA) (P<0.05) were decreased significantly, while ciliary body thickness (CBT) (P<0.05) increased significantly in UE eyes. UE grade analysis showed 7 eyes in grade 1, 9 eyes in grade 2, and 10 eyes in grade 3. Quadrant scores were performed of 4 eyes in 1 quadrant, 3 eyes in 3 quadrants, and 19 eyes in 4 quadrants. There was the positive correlation between grade and quadrant score (r=0.644, P=0.000). The effusion on all eyes were recovered after medication, which mean IOP was 13.9 (SD, 2.8) mm Hg. CONCLUSION UE is a frequent complication in Chinese patients after the attack of APAC, partially associated with hypotony. The severity of UE is correlation with height of effusion, extent of detachment, and shallower ACD. PMID:28393032
The effects of immersiveness on physiology.
Wiederhold, B K; Davis, R; Wiederhold, M D
1998-01-01
The effects of varying levels of immersion in virtual reality environments on participant's heart rate, respiration rate, peripheral skin temperature, and skin resistance levels were examined. Subjective reports of presence were also noted. Participants were presented with a virtual environment of an airplane flight both as seen from a two-dimensional computer screen and as seen from within a head-mounted display. Subjects were randomly assigned to different order of conditions presented, but all subjects received both conditions. Differences between the non-phobics' physiological responses and the phobic's response when placed in a virtual environment related to the phobia were noted. Also noted were changes in physiology based on degree of immersion.
Development of a virtual reality training curriculum for phacoemulsification surgery.
Spiteri, A V; Aggarwal, R; Kersey, T L; Sira, M; Benjamin, L; Darzi, A W; Bloom, P A
2014-01-01
Training within a proficiency-based virtual reality (VR) curriculum may reduce errors during real surgical procedures. This study used a scientific methodology to develop a VR training curriculum for phacoemulsification surgery (PS). Ten novice-(n) (performed <10 cataract operations), 10 intermediate-(i) (50-200), and 10 experienced-(e) (>500) surgeons were recruited. Construct validity was defined as the ability to differentiate between the three levels of experience, based on the simulator-derived metrics for two abstract modules (four tasks) and three procedural modules (five tasks) on a high-fidelity VR simulator. Proficiency measures were based on the performance of experienced surgeons. Abstract modules demonstrated a 'ceiling effect' with construct validity established between groups (n) and (i) but not between groups (i) and (e)-Forceps 1 (46, 87, and 95; P<0.001). Increasing difficulty of task showed significantly reduced performance in (n) but minimal difference for (i) and (e)-Anti-tremor 4 (0, 51, and 59; P<0.001), Forceps 4 (11, 73, and 94; P<0.001). Procedural modules were found to be construct valid between groups (n) and (i) and between groups (i) and (e)-Lens-cracking (0, 22, and 51; P<0.05) and Phaco-quadrants (16, 53, and 87; P<0.05). This was also the case with Capsulorhexis (0, 19, and 63; P<0.05) with the performance decreasing in the (n) and (i) group but improving in the (e) group (0, 55, and 73; P<0.05) and (0, 48, and 76; P<0.05) as task difficulty increased. Experienced/intermediate benchmark skill levels are defined allowing the development of a proficiency-based VR training curriculum for PS for novices using a structured scientific methodology.
Malware detection and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiang, Ken; Lloyd, Levi; Crussell, Jonathan
Embodiments of the invention describe systems and methods for malicious software detection and analysis. A binary executable comprising obfuscated malware on a host device may be received, and incident data indicating a time when the binary executable was received and identifying processes operating on the host device may be recorded. The binary executable is analyzed via a scalable plurality of execution environments, including one or more non-virtual execution environments and one or more virtual execution environments, to generate runtime data and deobfuscation data attributable to the binary executable. At least some of the runtime data and deobfuscation data attributable tomore » the binary executable is stored in a shared database, while at least some of the incident data is stored in a private, non-shared database.« less
Effect of virtual reality headset for pediatric fear and pain distraction during immunization.
Chad, Rudnick; Emaan, Sulaiman; Jillian, Orden
2018-05-03
Fear of needles is a well-known phobia among children and adults. This study presents the rationale, feasibility and results of a pilot study applying a virtual reality (VR) headset as a fear reduction and pain distraction during immunizations. 17 subjects and 17 parents rated their fear and pain level pre- and postimmunization using Wong-Baker pain scale and McMurtry children's fear scale. Immunization was provided, while subject was wearing a VR headset. Ratings of anticipated versus actual fear and pain due to immunizations improved following use of the VR headset in 94.1% of pediatric subjects. The use of a VR headset was well received and reduced overall fear and pain in children receiving immunizations.
An experiment on fear of public speaking in virtual reality.
Pertaub, D P; Slater, M; Barker, C
2001-01-01
Can virtual reality exposure therapy be used to treat people with social phobia? To answer this question it is vital to known if people will respond to virtual humans (avatars) in a virtual social setting in the same way they would to real humans. If someone is extremely anxious with real people, will they also be anxious when faced with simulated people, despite knowing that the avatars are computer generated? In [17] we described a small pilot study that placed 10 people before a virtual audience. The purpose was to assess the extent to which social anxiety, specifically fear of public speaking, was induced by the virtual audience and the extent of influence of degree of immersion (head mounted display or desktop monitor. The current paper describes a follow up study conducted with 40 subjects and the results clearly show that not only is social anxiety induced by the audience, but the degree of anxiety experienced is directly related to the type of virtual audience feedback the speaker receives. In particular, a hostile negative audience scenario was found to generate strong affect in speakers, regardless of whether or not they normally suffered from fear of public speaking.
2018-01-01
Objective To evaluate the impact of using a ‘virtual clinic’ on patient experience and cost in the care of women with urinary incontinence. Materials and methods Women, aged > 18 years referred to a urogynaecology unit were randomised to either (1) A Standard Clinic or (2) A Virtual Clinic. Both groups completed a validated, web-based interactive, patient-reported outome measure (ePAQ-Pelvic Floor), in advance of their appointment followed by either a telephone consultation (Virtual Clinic) or face-to-face consultation (Standard Care). The primary outcome was the mean ‘short-term outcome scale’ score on the Patient Experience Questionnaire (PEQ). Secondary Outcome Measures included the other domains of the PEQ (Communications, Emotions and Barriers), Client Satisfaction Questionnaire (CSQ), Short-Form 12 (SF-12), personal, societal and NHS costs. Results 195 women were randomised: 98 received the intervention and 97 received standard care. The primary outcome showed a non-significant difference between the two study arms. No significant differences were also observed on the CSQ and SF-12. However, the intervention group showed significantly higher PEQ domain scores for Communications, Emotions and Barriers (including following adjustment for age and parity). Whilst standard care was overall more cost-effective, this was minimal (£38.04). The virtual clinic also significantly reduced consultation time (10.94 minutes, compared with a mean duration of 25.9 minutes respectively) and consultation costs compared to usual care (£31.75 versus £72.17 respectively), thus presenting potential cost-savings in out-patient management. Conclusions The virtual clinical had no impact on the short-term dimension of the PEQ and overall was not as cost-effective as standard care, due to greater clinic re-attendances in this group. In the virtual clinic group, consultation times were briefer, communication experience was enhanced and personal costs lower. For medical conditions of a sensitive or intimate nature, a virtual clinic has potential to support patients to communicate with health professionals about their condition. PMID:29346378
1984-05-01
QUADRANT —where it was agreed a diversionary attack -for OVERLORD would take place in southern France. The operation, as proposed by the Americans...diversionary attack in southern France was codified by the American and British leadership at QUADRANT , the issue was again heavily debated by the "Big...the outcome at the war. Ore can ssv that the outcome ot the war in Europa was decided when operation OVERLORD was approved ior execution. The battle
Dual pathology in a patient with right lower quadrant pain.
Deutsch, Gary B; Sathyanarayana, Sandeep Anantha; Nicastro, Jeffrey; Molmenti, Ernesto; Coppa, Gene; Rubach, Eugene; Friedman, Barak
2012-09-01
Meckel diverticula are remnants of the omphalomesenteric duct. They have 2% incidence in the general population, are usually asymptomatic, and tend to be diagnosed incidentally. The generally held principle had been that asymptomatic cases do not require resection, as exemplified by a 2008 systematic review of over 200 studies. However, a recent series reported an increased risk of malignancies, and recommended mandatory resection. We present a case of Meckel diverticulitis with concurrent infiltrative appendiceal carcinoid in a patient with right lower quadrant pain.
Dual Pathology in a Patient with Right Lower Quadrant Pain
Deutsch, Gary B.; Sathyanarayana, Sandeep Anantha; Nicastro, Jeffrey; Molmenti, Ernesto; Coppa, Gene; Rubach, Eugene; Friedman, Barak
2012-01-01
Meckel diverticula are remnants of the omphalomesenteric duct. They have 2% incidence in the general population, are usually asymptomatic, and tend to be diagnosed incidentally. The generally held principle had been that asymptomatic cases do not require resection, as exemplified by a 2008 systematic review of over 200 studies. However, a recent series reported an increased risk of malignancies, and recommended mandatory resection. We present a case of Meckel diverticulitis with concurrent infiltrative appendiceal carcinoid in a patient with right lower quadrant pain. PMID:23997560
2010-11-01
Connecting the Medtronic MAST Quadrant Illumination System, Radiance Illumination System, or Radiance X Illumination System--all of which are specialized fiberoptic light cables used with the company's minimally invasive spinal products--to a high-power surgical light source significantly increases the risk of patient burns. Hospitals should ensure that the products are used only with 100 W light sources and 5 mm light cables, as prescribed in the product labeling.
3D Seismic Imaging using Marchenko Methods
NASA Astrophysics Data System (ADS)
Lomas, A.; Curtis, A.
2017-12-01
Marchenko methods are novel, data driven techniques that allow seismic wavefields from sources and receivers on the Earth's surface to be redatumed to construct wavefields with sources in the subsurface - including complex multiply-reflected waves, and without the need for a complex reference model. In turn, this allows subsurface images to be constructed at any such subsurface redatuming points (image or virtual receiver points). Such images are then free of artefacts from multiply-scattered waves that usually contaminate migrated seismic images. Marchenko algorithms require as input the same information as standard migration methods: the full reflection response from sources and receivers at the Earth's surface, and an estimate of the first arriving wave between the chosen image point and the surface. The latter can be calculated using a smooth velocity model estimated using standard methods. The algorithm iteratively calculates a signal that focuses at the image point to create a virtual source at that point, and this can be used to retrieve the signal between the virtual source and the surface. A feature of these methods is that the retrieved signals are naturally decomposed into up- and down-going components. That is, we obtain both the signal that initially propagated upwards from the virtual source and arrived at the surface, separated from the signal that initially propagated downwards. Figure (a) shows a 3D subsurface model with a variable density but a constant velocity (3000m/s). Along the surface of this model (z=0) in both the x and y directions are co-located sources and receivers at 20-meter intervals. The redatumed signal in figure (b) has been calculated using Marchenko methods from a virtual source (1200m, 500m and 400m) to the surface. For comparison the true solution is given in figure (c), and shows a good match when compared to figure (b). While these 2D redatuming and imaging methods are still in their infancy having first been developed in 2012, we have extended them to 3D media and wavefields. We show that while the wavefield effects may be more complex in 3D, Marchenko methods are still valid, and 3D images that are free of multiple-related artefacts, are a realistic possibility.
NASA Astrophysics Data System (ADS)
Bainbridge, William Sims; Lutters, Wayne; Rhoten, Diana; Lowood, Henry
This book, like the May 2008 conference in World of Warcraft, ends with projections toward what the future might hold for virtual worlds. Every chapter thus far has included speculations about future directions, even while standing on data from the past. This last chapter, like the final session of the conference on which it is based, incorporates comments from dozens of participants into a stream of ideas. We have edited selected comments together with the panel's contributions. Our intention is to provide a portal from this book into a wider virtual community comprising researchers and residents in virtual worlds. The discussion surveys many recent lines of development, some of which have already been surveyed in scientific and historical literature, or by journalists (Au 2008; Castronova 2007; Guest 2007; Ludlow and Wallace 2007). Yet, many of the topics here have not received such attention. Considered as a set of socio-technical innovations, virtual worlds are not just about technical possibilities; they also inspired the participants to consider the economic bases for investing in those possibilities and the novel cultural, social, and artistic forms virtual worlds might offer.
A Virtual Aluminum Reduction Cell
NASA Astrophysics Data System (ADS)
Zhang, Hongliang; Zhou, Chenn Q.; Wu, Bing; Li, Jie
2013-11-01
The most important component in the aluminum industry is the aluminum reduction cell; it has received considerable interests and resources to conduct research to improve its productivity and energy efficiency. The current study focused on the integration of numerical simulation data and virtual reality technology to create a scientifically and practically realistic virtual aluminum reduction cell by presenting complex cell structures and physical-chemical phenomena. The multiphysical field simulation models were first built and solved in ANSYS software (ANSYS Inc., Canonsburg, PA, USA). Then, the methodology of combining the simulation results with virtual reality was introduced, and a virtual aluminum reduction cell was created. The demonstration showed that a computer-based world could be created in which people who are not analysis experts can see the detailed cell structure in a context that they can understand easily. With the application of the virtual aluminum reduction cell, even people who are familiar with aluminum reduction cell operations can gain insights that make it possible to understand the root causes of observed problems and plan design changes in much less time.
Embodying self-compassion within virtual reality and its effects on patients with depression.
Falconer, Caroline J; Rovira, Aitor; King, John A; Gilbert, Paul; Antley, Angus; Fearon, Pasco; Ralph, Neil; Slater, Mel; Brewin, Chris R
2016-01-01
Self-criticism is a ubiquitous feature of psychopathology and can be combatted by increasing levels of self-compassion. However, some patients are resistant to self-compassion. To investigate whether the effects of self-identification with virtual bodies within immersive virtual reality could be exploited to increase self-compassion in patients with depression. We developed an 8-minute scenario in which 15 patients practised delivering compassion in one virtual body and then experienced receiving it from themselves in another virtual body. In an open trial, three repetitions of this scenario led to significant reductions in depression severity and self-criticism, as well as to a significant increase in self-compassion, from baseline to 4-week follow-up. Four patients showed clinically significant improvement. The results indicate that interventions using immersive virtual reality may have considerable clinical potential and that further development of these methods preparatory to a controlled trial is now warranted. None. © The Royal College of Psychiatrists 2016. This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY) licence.
Park, D C; Puglisi, J T; Sovacool, M
1983-09-01
In the present study the spatial location of picture and word stimuli was varied across four quadrants of photographic slides. Young and old people received either pictures or words to study and were told to remember either just the item or the item and its location. Recognition memory for items and memory for spatial location were tested. A pictorial superiority effect occurred for both old and young people's item recognition. Additionally, instructions to study position decreased item memory and facilitated position memory in both age groups. Spatial memory was markedly superior for pictures compared with matched words for old and young adults. The results are interpreted within the Hasher and Zacks framework of automatic processing. The implications of the data for designing mnemonic aids for elderly persons are considered.
Saposnik, G; Mamdani, M; Bayley, M; Thorpe, K E; Hall, J; Cohen, L G; Teasell, R
2010-02-01
Evidence suggests that increasing intensity of rehabilitation results in better motor recovery. Limited evidence is available on the effectiveness of an interactive virtual reality gaming system for stroke rehabilitation. EVREST was designed to evaluate feasibility, safety and efficacy of using the Nintendo Wii gaming virtual reality (VRWii) technology to improve arm recovery in stroke patients. Pilot randomized study comparing, VRWii versus recreational therapy (RT) in patients receiving standard rehabilitation within six months of stroke with a motor deficit of > or =3 on the Chedoke-McMaster Scale (arm). In this study we expect to randomize 20 patients. All participants (age 18-85) will receive customary rehabilitative treatment consistent of a standardized protocol (eight sessions, 60 min each, over a two-week period). The primary feasibility outcome is the total time receiving the intervention. The primary safety outcome is the proportion of patients experiencing intervention-related adverse events during the study period. Efficacy, a secondary outcome measure, will be measured by the Wolf Motor Function Test, Box and Block Test, and Stroke Impact Scale at the four-week follow-up visit. From November, 2008 to September, 2009 21 patients were randomized to VRWii or RT. Mean age, 61 (range 41-83) years. Mean time from stroke onset 25 (range 10-56) days. EVREST is the first randomized parallel controlled trial assessing the feasibility, safety, and efficacy of virtual reality using Wii gaming technology in stroke rehabilitation. The results of this study will serve as the basis for a larger multicentre trial. ClinicalTrials.gov registration# NTC692523.
Space Weathering of the Lunar Surface by Solar Wind Particles
NASA Astrophysics Data System (ADS)
Kim, Sungsoo S.; Sim, Chaekyung
2017-08-01
The lunar regolith is space-weathered to a different degree in response to the different fluxes of incident solar wind particles and micrometeoroids. Crater walls, among other slating surfaces, are good tracers of the space-weathering process because they mature differently depending on the varying incident angles of weathering agents. We divide a crater wall into four quadrants (north, south, east, and west) and analyze the distribution of 950-nm/750-nm reflectance-ratio and 750-nm reflectance values in each wall quadrant, using the topography-corrected images by Multispectral Imager (MI) onboard SELENE (Kaguya). For thousands of impact craters across the Moon, we interpret the spectral distributions in the four wall quadrants in terms of the space weathering by solar wind particles and micrometeoroids and of gardening by meteroids. We take into account the solar-wind shielding by the Earth’s magnetotail to correctly assess the different spectral behaviors between east- and west-facing walls of the craters in the near-side of the Moon.
Insight into the da Vinci® Xi - technical notes for single-docking left-sided colorectal procedures.
Ngu, James Chi-Yong; Sim, Sarah; Yusof, Sulaiman; Ng, Chee-Yung; Wong, Andrew Siang-Yih
2017-12-01
The adoption of robot-assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi-quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left-sided colorectal procedures. Our initial series of left-sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Between March 2015 and April 2016, 54 cases of robot-assisted laparoscopic left-sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi-quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. The da Vinci® Xi simplifies the docking procedure and makes single-docking feasible for multi-quadrant left-sided colorectal procedures. Copyright © 2016 John Wiley & Sons, Ltd.
The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT
NASA Technical Reports Server (NTRS)
Dere, K. P.; Moses, J. D.; Delaboudiniere, J. -P.; Brunaud, J.; Carabetian, C.; Hochedez, J. -F.; Song, X. Y.; Catura, R. C.; Clette, F.; Defise, J. -M.
2000-01-01
This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.
Delmore, J.E.
1984-05-01
A method and apparatus for providing a negative ion source accelerates electrons away from a hot filament electron emitter into a region of crossed electric and magnetic fields arranged in a magnetron configuration. During a portion of the resulting cycloidal path, the electron velocity is reduced below its initial value. The electron accelerates as it leaves the surface at a rate of only slightly less than if there were no magnetic field, thereby preventing a charge buildup at the surface of the emitter. As the electron traverses the cycloid, it is decelerated during the second, third, and fourth quadrants, then reaccelerated as it approaches the end of the fourth quadrant to regain its original velocity. The minimum velocity occurs during the fourth quadrant, and corresponds to an electron temperature of 200 to 500/sup 0/C for the electric and magnetic fields commonly encountered in the ion sources of magnetic sector mass spectrometers. An ion source using the above-described thermalized electrons is also disclosed.
Unusual case of acute appendicitis with left upper quadrant abdominal pain.
Tawk, Charbel M; Zgheib, Rana R; Mehanna, Seba
2012-01-01
Acute appendicitis is one of the most frequent causes of surgical abdominal pain presenting to the Emergency Department. The diagnosis is confirmed by a set of clinical signs, blood tests and imaging. The typical presentation consists of periumbilical pain radiating to the right lower quadrant with peritoneal reaction on palpation (Mac Burney). In this article, we report a case of acute appendicitis presenting with a left upper quadrant pain due to intestinal malrotation and we describe the radiologic findings on computed tomography. With an Alvarado score of 4 and a nonconclusive abdominal U/S, the diagnosis of acute appendicitis was a long shot. Persistence of pain and increasing inflammatory parameters in her blood exams pushed the medical team to further investigate and a CT scan revealed intestinal malrotation with acute appendicitis. An examining physician should not be mislead by the atypical presentation of acute appendicitis and should bear in mind the diagnosis to avoid serious complications. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Ji, Fang-Fang; Gao, Peng; Wang, Ji-Gang; Zhao, Jie
2012-01-01
Carcinoma metastatic to breast from extra-mammary malignancy is rare and only accounts for 0.4-1.3% of all breast cancer. Two rare cases of single breast metastasis from pulmonary adenocarcinoma were reported here with a brief review of the pertinent literature. The only complaint of the these two female patients was painless breast mass found recently. Most breast metastasis previously reported are present in the upper outer quadrant, however, in our study, one case was found to be located in the lower inner quadrant and the other in the upper inner quadrant. Tumor cells from breast biopsy were immune-positive for thyroid transcription factor-1. The two patients survived 5 and 8 months, respectively, following the diagnosis of both the primary lung tumor and the breast metastasis. Breast metastasis from lung adenocarcinoma is rare but does exist. The awareness of this possibility may help to differentiate the tumor from primary breast carcinoma. Clinical history and immunohistochemical studies are essential to reach the final diagnosis. PMID:22934141
Relationship between relative lens position and appositional closure in eyes with narrow angles.
Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako
2011-03-01
To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.
Laparoscopic skills acquisition: a study of simulation and traditional training.
Marlow, Nicholas; Altree, Meryl; Babidge, Wendy; Field, John; Hewett, Peter; Maddern, Guy J
2014-12-01
Training in basic laparoscopic skills can be undertaken using traditional methods, where trainees are educated by experienced surgeons through a process of graduated responsibility or by simulation-based training. This study aimed to assess whether simulation trained individuals reach the same level of proficiency in basic laparoscopic skills as traditional trained participants when assessed in a simulated environment. A prospective study was undertaken. Participants were allocated to one of two cohorts according to surgical experience. Participants from the inexperienced cohort were randomized to receive training in basic laparoscopic skills on either a box trainer or a virtual reality simulator. They were then assessed on the simulator on which they did not receive training. Participants from the experienced cohort, considered to have received traditional training in basic laparoscopic skills, did not receive simulation training and were randomized to either the box trainer or virtual reality simulator for skills assessment. The assessment scores from different cohorts on either simulator were then compared. A total of 138 participants completed the assessment session, 101 in the inexperienced simulation-trained cohort and 37 on the experienced traditionally trained cohort. There was no statistically significant difference between the training outcomes of simulation and traditionally trained participants, irrespective of the simulator type used. The results demonstrated that participants trained on either a box trainer or virtual reality simulator achieved a level of basic laparoscopic skills assessed in a simulated environment that was not significantly different from participants who had been traditionally trained in basic laparoscopic skills. © 2013 Royal Australasian College of Surgeons.
López-Martín, Olga; Segura Fragoso, Antonio; Rodríguez Hernández, Marta; Dimbwadyo Terrer, Iris; Polonio-López, Begoña
2016-01-01
To evaluate the effectiveness of a programme based on a virtual reality game to improve cognitive domains in patients with schizophrenia. A randomized controlled trial was conducted in 40 patients with schizophrenia, 20 in the experimental group and 20 in the control group. The experimental group received 10 sessions with Nintendo Wii(®) for 5 weeks, 50 minutes/session, 2 days/week in addition to conventional treatment. The control group received conventional treatment only. Statistically significant differences in the T-Score were found in 5 of the 6 cognitive domains assessed: processing speed (F=12.04, p=0.001), attention/vigilance (F=12.75, p=0.001), working memory (F=18.86, p <0.01), verbal learning (F=7.6, p=0.009), visual learning (F=3.6, p=0.064), and reasoning and problem solving (F=11.08, p=0.002). Participation in virtual reality interventions aimed at cognitive training have great potential for significant gains in different cognitive domains assessed in patients with schizophrenia. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.
The combined use of virtual reality exposure in the treatment of agoraphobia.
Pitti, Carmen T; Peñate, Wenceslao; de la Fuente, Juan; Bethencourt, Juan M; Roca-Sánchez, María J; Acosta, Leopoldo; Villaverde, María L; Gracia, Ramón
2015-01-01
This study compares the differential efficacy of three groups of treatments for agoraphobia: paroxetine combined with cognitive-behavioral therapy, paroxetine combined with cognitive-behavioral therapy and virtual reality exposure, and a group with only paroxetine. 99 patients with agoraphobia were finally selected. Both combined treatment groups received 11 sessions of cognitive-behavioral therapy, and one of the groups was also exposed to 4 sessions of virtual reality treatment. Treatments were applied in individual sessions once a week for 3 months. The three treatment groups showed statistically significant improvements. In some measures, combined treatment groups showed greater improvements. The virtual reality exposure group showed greater improvement confronting phobic stimuli. Treatments combining psychopharmacological and psychological therapy showed greater efficacy. Although the use of new technologies led to greater improvement, treatment adherence problems still remain.
Effect of virtual reality on cognition in stroke patients.
Kim, Bo Ryun; Chun, Min Ho; Kim, Lee Suk; Park, Ji Young
2011-08-01
To investigate the effect of virtual reality on the recovery of cognitive impairment in stroke patients. Twenty-eight patients (11 males and 17 females, mean age 64.2) with cognitive impairment following stroke were recruited for this study. All patients were randomly assigned to one of two groups, the virtual reality (VR) group (n=15) or the control group (n=13). The VR group received both virtual reality training and computer-based cognitive rehabilitation, whereas the control group received only computer-based cognitive rehabilitation. To measure, activity of daily living cognitive and motor functions, the following assessment tools were used: computerized neuropsychological test and the Tower of London (TOL) test for cognitive function assessment, Korean-Modified Barthel index (K-MBI) for functional status evaluation, and the motricity index (MI) for motor function assessment. All recruited patients underwent these evaluations before rehabilitation and four weeks after rehabilitation. The VR group showed significant improvement in the K-MMSE, visual and auditory continuous performance tests (CPT), forward digit span test (DST), forward and backward visual span tests (VST), visual and verbal learning tests, TOL, K-MBI, and MI scores, while the control group showed significant improvement in the K-MMSE, forward DST, visual and verbal learning tests, trail-making test-type A, TOL, K-MBI, and MI scores after rehabilitation. The changes in the visual CPT and backward VST in the VR group after rehabilitation were significantly higher than those in the control group. Our findings suggest that virtual reality training combined with computer-based cognitive rehabilitation may be of additional benefit for treating cognitive impairment in stroke patients.
Lack of Pannexin 1 Alters Synaptic GluN2 Subunit Composition and Spatial Reversal Learning in Mice.
Gajardo, Ivana; Salazar, Claudia S; Lopez-Espíndola, Daniela; Estay, Carolina; Flores-Muñoz, Carolina; Elgueta, Claudio; Gonzalez-Jamett, Arlek M; Martínez, Agustín D; Muñoz, Pablo; Ardiles, Álvaro O
2018-01-01
Long-term potentiation (LTP) and long-term depression (LTD) are two forms of synaptic plasticity that have been considered as the cellular substrate of memory formation. Although LTP has received considerable more attention, recent evidences indicate that LTD plays also important roles in the acquisition and storage of novel information in the brain. Pannexin 1 (Panx1) is a membrane protein that forms non-selective channels which have been shown to modulate the induction of hippocampal synaptic plasticity. Animals lacking Panx1 or blockade of Pannexin 1 channels precludes the induction of LTD and facilitates LTP. To evaluate if the absence of Panx1 also affects the acquisition of rapidly changing information we trained Panx1 knockout (KO) mice and wild type (WT) littermates in a visual and hidden version of the Morris water maze (MWM). We found that KO mice find the hidden platform similarly although slightly quicker than WT animals, nonetheless, when the hidden platform was located in the opposite quadrant (OQ) to the previous learned location, KO mice spent significantly more time in the previous quadrant than in the new location indicating that the absence of Panx1 affects the reversion of a previously acquired spatial memory. Consistently, we observed changes in the content of synaptic proteins critical to LTD, such as GluN2 subunits of N-methyl-D-aspartate receptors (NMDARs), which changed their contribution to synaptic plasticity in conditions of Panx1 ablation. Our findings give further support to the role of Panx1 channels on the modulation of synaptic plasticity induction, learning and memory processes.
Hasenöhrl, R U; Gerhardt, P; Huston, J P
1990-12-01
Possible positive reinforcing and aversive effects of intraperitoneally (ip) administered substance P (SP) and its C-terminal heptapeptide analog [pGlu5, MePhe8, Sar9]-SP5-11 (DIME-C7) were investigated in rats. The 'conditioned corral preference and avoidance procedure' was used for assessing positive and negative reinforcement. Behavioural testing was conducted in a circular open field consisting of four uniform quadrants equally preferred by the rats prior to drug treatment. On 3 consecutive days, rats received an ip injection of either SP (37 nmol/kg), DIME-C7 (3.7, 7.4, 37, 185 nmol/kg) or vehicle (0.01 M acetic acid in saline) and were placed immediately into their assigned treatment corral. During the test for conditioned corral preference and avoidance, when provided a choice between the four quadrants, rats treated with SP and with the equimolar dose of DIME-C7 (37 nmol/kg) spent significant more time in the drug-paired corral, indicative of positive reinforcing effects. The doses of 3.7 and 7.4 nmol/kg DIME-C7 did not influence the preference behaviour. The high dose of 185 nmol/kg DIME-C7 led to a significant decrease in time spent in the previously drug-paired corral, suggestive of aversive effects of the treatment. Gross locomotor activity was not influenced by either treatment. These results are discussed in the framework of a structure/activity relationship for the reinforcing properties of peripheraly applied SP.
A clinical comparison between nickel titanium springs and elastomeric chains.
Bokas, Jim; Woods, Michael
2006-05-01
To compare the rates of maxillary canine retraction and molar anchorage loss when using either NiTi springs or elastomeric chains delivering a known force with sliding edgewise mechanics. Twelve patients who required maxillary canine retraction into first premolar extraction sites as part of their orthodontic treatment were selected. In a split-mouth design, these patients received precalibrated NiTi springs (112 quadrants) and pre-measured elastomeric chains (12 quadrants), all delivering initial forces of approximately 200 g and being reactivated at 28 day intervals. Space closure and forward movement of the maxillary first molars were evaluated using maxillary impressions, which were taken before the start of canine retraction and then at 28 day intervals until canine retraction was almost complete. Statistical analysis revealed that the mean rate of space closure with NiTi springs (1.85 mm/month) was only 0.17 mm/month greater (p = 0.011) than that produced with the elastomeric chains (1.68 mm/month). The mean rates of anchorage loss for the NiTi springs and elastomeric chain were 0.46 mm/month and 0.45 mm/month respectively. This difference was not statistically significant. These amounts of forward molar movement were calculated to be between one quarter and one third of the average space closure per month, even in the presence of a fixed transpalatal arch. The results indicate that the rates of space closure and molar anchorage loss using either NiTi springs or elastomeric chains, if reactivated every 28 days, are likely to be similar.
Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira
2004-12-01
To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nugraha, Andri Dian; Adisatrio, Philipus Ronnie
2013-09-09
Seismic refraction survey is one of geophysical method useful for imaging earth interior, definitely for imaging near surface. One of the common problems in seismic refraction survey is weak amplitude due to attenuations at far offset. This phenomenon will make it difficult to pick first refraction arrival, hence make it challenging to produce the near surface image. Seismic interferometry is a new technique to manipulate seismic trace for obtaining Green's function from a pair of receiver. One of its uses is for improving first refraction arrival quality at far offset. This research shows that we could estimate physical properties suchmore » as seismic velocity and thickness from virtual refraction processing. Also, virtual refraction could enhance the far offset signal amplitude since there is stacking procedure involved in it. Our results show super - virtual refraction processing produces seismic image which has higher signal-to-noise ratio than its raw seismic image. In the end, the numbers of reliable first arrival picks are also increased.« less
Zamani, Zohre; Reisi, Parham; Alaei, Hojjatallah; Pilehvarian, Ali Asghar
2012-01-01
Background: It has been recently demonstrated that Royal jelly (RJ) has a beneficial role on neural functions. Alzheimer's disease (AD) is associated with impairments of learning and memory. Therefore, the present study was designed to examine the effect of RJ on spatial learning and memory in rats after intracerebroventricular injection of streptozotocin (icv-STZ). Materials and Methods: Rats were infused bilaterally with an icv injection of STZ, while sham rats received vehicle only. The rats were feed with RJ-contained food (3% w/w) (lyophilized RJ mixed with powdered regular food) or regular food for 10 days. Then spatial learning and memory was tested in the rats by Morris water maze test. Results: Results showed that in icv-STZ group latency and path length were increased as compared to sham group, also icv-STZ rats less remembered the target quadrant that previously the platform was located; however, these were protected significantly in STZ group that received RJ-containing food. Conclusions: Our findings support the potential neuroprotective role of RJ and its helpful effects in AD. PMID:23210085
Simultaneous surgeries in a split forward surgical team: a case study.
Vanfosson, Christopher A; Seery, Jason M
2011-12-01
The 541st Forward Surgical Team performed split-based operations, with one site in the city of Pol-e-Khumri. One evening, the 10-person team received two pediatric patients simultaneously and conducted simultaneous surgeries. The 3-year-old female sustained severe injuries to bilateral lower extremities and a puncture wound to her right forearm. The 13-year-old sustained fragmentary wounds to her left hand, left foot, right medial calf, and evisceration to her left lower quadrant. The patients presented in extremis after being taken to a civilian hospital initially, spending approximately 1.5 hours receiving no resuscitative therapy. The 3-year-old underwent amputations of bilateral lower extremities and a fasciotomy of the right forearm. The 13-year-old survived an exploratory laparotomy and irrigation and debridement of intra-abdominal wounds. The successful completion of simultaneous surgeries, by a split forward surgical team at a remote location, for two critically ill patients is possible. It should not become the standard of care. Prior planning made this occurrence feasible and safer, but such situations put the patients at risk for complications.
[Hepatic pseudotumor in acute fascioliasis].
Castillo Contreras, Ofelia Brisaida; Frisancho Velarde, Oscar
2013-03-01
We report a 61-year-old woman who was hospitalized because of abdominal pain in the right upper quadrant related to a liver tumor (ultrasound and tomographic findings). A collection of blood was obtained by a biopsy and there were no tumor cells. With the suspicion of acute fascioliasis (liver stage), due to severe eosinophilia and recent travel to endemic area of Fasciola hepatica, arc II and ELISA Fas 2 we carried out and were positive. Parasitological stool examinations were negative. During hospitalization a hepatic subcapsular hematoma presented as a complication and the patient developed fever because of cholangiolitic microabscesses in the left hepatic lobe. Percutaneous drainage was performed and positive cultures of secretions were obtained She received antibiotic coverage with vancomycin and imipenem. Treatment for Fasciola hepatica was initiated with nitaxozanida but it was discontinued due to oral intolerance. Later, she received a single dose of 250 mg triclabendazole with clinical and laboratory improvement. We presented this case because it is an unusual pseudotumoral presentation in acute hepatic fascioliasis. This parasitic disease is an emerging zoonosis in Perú.
Feeding Vitamin C during Neonatal and Juvenile Growth Improves Learning and Memory of Rats.
Hosseini, Mahmoud; Beheshti, Farimah; Sohrabi, Farzaneh; Vafaee, Farzaneh; Shafei, Mohammad Naser; Reza Sadeghnia, Hamid
2018-09-03
We investigated the effects of feeding vitamin C (Vit C) during neonatal and juvenile growth on learning and memory of rats. Rats after delivery were randomly divided into four groups and treated. Group 1, control group, received normal drinking water. Groups 2-4 received Vit C 10, 100, and 500 mg/kg, respectively, from the first day. After 8 weeks, 10 male offspring of each group were randomly selected and tested in the Morris water maze (MWM) and passive avoidance (PA) tests. Finally, the brains were removed for biochemical measurement. In MWM, 10-500 mg/kg Vit C reduced the latency and traveled distance and increased time spent in the target quadrant. In PA, 10 and 100 mg/kg of Vit C increased the latency; 10-500 mg/kg of Vit C decreased the malondialdehyde (MDA) in the brain tissues and increased thiol and catalase (CAT) activity compared to the control group. We showed that feeding rats Vit C during neonatal and juvenile growth has positive effects on learning and memory.
Physical Activity Characteristics across GOLD Quadrants Depend on the Questionnaire Used
Demeyer, Heleen; Gimeno-Santos, Elena; Rabinovich, Roberto A.; Hornikx, Miek; Louvaris, Zafeiris; de Boer, Willem I.; Karlsson, Niklas; de Jong, Corina; Van der Molen, Thys; Vogiatzis, Ioannis; Janssens, Wim; Garcia-Aymerich, Judith; Troosters, Thierry; Polkey, Michael I.
2016-01-01
Background The GOLD multidimensional classification of COPD severity combines the exacerbation risk with the symptom experience, for which 3 different questionnaires are permitted. This study investigated differences in physical activity (PA) in the different GOLD quadrants and patient’s distribution in relation to the questionnaire used. Methods 136 COPD patients (58±21% FEV1 predicted, 34F/102M) completed COPD assessment test (CAT), clinical COPD questionnaire (CCQ) and modified Medical Research Council (mMRC) questionnaire. Exacerbation history, spirometry and 6MWD were collected. PA was objectively measured for 2 periods of 1 week, 6 months apart, in 5 European centres; to minimise seasonal and clinical variation the average of these two periods was used for analysis. Results GOLD quadrants C+D had reduced PA compared with A+B (3824 [2976] vs. 5508 [4671] steps.d-1, p<0.0001). The choice of questionnaire yielded different patient distributions (agreement mMRC-CAT κ = 0.57; CCQ-mMRC κ = 0.71; CCQ-CAT κ = 0.72) with different clinical characteristics. PA was notably lower in patients with an mMRC score ≥2 (3430 [2537] vs. 5443 [3776] steps.d-1, p <0.001) in both the low and high risk quadrants. Conclusions Using different questionnaires changes the patient distribution and results in different clinical characteristics. Therefore, standardization of the questionnaire used for classification is critical to allow comparison of different studies using this as an entry criterion. Clinical Trial Registration ClinicalTrials.gov NCT01388218 PMID:26974332
Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration
2013-01-01
Objective To determine the feasibility of measuring tympanic membrane (TM) vibrations at multiple locations on the TM to differentiate normal eardrums from those with associated ossicular pathologies. Design Cadaveric human temporal bone study. Setting Basic science laboratory. Methods A mastoidectomy and facial recess approach was performed on four cadaveric temporal bones to obtain access to the ossicles without disrupting the TM. Ossicles were palpated to ensure normal mobility and an intact ossicular chain. Laser Doppler Vibrometry (LDV) measurements were then taken on all four TMs. LDV measurements were repeated on each TM following stapes footplate fixation, incudo-stapedial joint dislocation, and malleus head fixation. Main outcome measures LDV measurements of TM vibration at the umbo, the lateral process of the malleus, and in each of the four quadrants of the TM. Results The best signal-to-noise ratios were found between 2 and 4 kHz, at the umbo, the anterior superior quadrant, the anterior inferior quadrant, and the posterior inferior quadrant. Since our goal was to assess the ossicular chain, we selected the TM locations closest to the ossicular chain (the umbo and lateral process of the malleus) for further analysis. Differences could be seen between normals and the simulated ossicular pathologies, but values were not statistically significant. Conclusions LDV measurements are technically challenging and require optimization to obtain consistent measurements. This study demonstrates the potential of LDV to differentiate ossicular pathologies behind an intact tympanic membrane. Future studies will further characterize the clinical role of this diagnostic modality. PMID:23663748
Fahmy, Rania M; Bhat, Ramesa S; Al-Mutairi, Manar; Aljaser, Feda S; El-Ansary, Afaf
2018-01-01
Objective To evaluate the effect of diabetes mellitus (DM), diabetic retinopathy, and degree of glycemic control (glycosylated hemoglobin [HbA1c]) on peripapillary retinal nerve fiber layer thickness (RNFLT) using optical coherence tomography. Methods The study included 126 eyes of healthy controls (n=32) and diabetics patients (n=31), whose ages ranged from 40 to 70 years. The diabetic group was divided into: Subgroup 1: with HbA1c <7% and Subgroup 2: with HbA1c ≥7%. All patients underwent full ophthalmic examination. HbA1c level was obtained with the A1cNow+ system and the peripapillary RNFLT was measured using 3D-OCT 2000 Topcon (360-degree circular scan with 3.4 mm diameter centered on optic disc). Results The obtained data demonstrates significant decrease in peripapillary RNFLT in superior and inferior quadrants of the right eye (p=0.000 and p=0.039, respectively), and in superior quadrant of the left eye (p=0.002) with impairment of glycemic control. Pearson’s correlation test showed significant negative correlation of RNFLT with HbA1c in the superior quadrant in both eyes. Conclusion Impairment of glycemic control affects the peripapillary RNFLT mainly in the superior quadrant. This thickness also tends to decrease with long-standing DM, use of DM medications, and development of diabetic retinopathy. The measurement of peripapillary RNFLT may become a useful method to monitor early retinal changes in diabetic patients. PMID:29535499
Reliability Assessment of Graphite Specimens under Multiaxial Stresses
NASA Technical Reports Server (NTRS)
Sookdeo, Steven; Nemeth, Noel N.; Bratton, Robert L.
2008-01-01
An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.
An application of belief-importance theory in the domain of academic achievement.
Petrides, K V; Frederickson, Norah
2011-03-01
BACKGROUND. Belief-importance (belimp; Petrides, 2010a,b) theory posits that personality traits confer on the individual a propensity to perceive convergences and divergences between their belief that they can attain goals and the importance that they place on these goals. The theory suggests that these convergences and divergences have important implications for affect, motivation, and action. AIMS. To test belimp theory using performance-based criteria relating to academic achievement and constructs from the personality domain. SAMPLES. Two hundred and forty-two students, of whom 121 were male and 117 were female (4 unreported). They were approximately 18 years old at the time of testing. METHODS. Data were collected on the belief and importance of academic achievement, the Giant Three personality dimensions, and trait emotional intelligence (trait EI). Academic achievement was operationalized via Key Stage 3 and A-level assessment results. RESULTS. Four hypotheses concerning academic achievement were tested and confirmed, with the Motivation quadrant scoring higher than the other three belimp quadrants (Hubris, Depression, and Apathy). Four hypotheses concerning personality were tested, of which two were confirmed, with the Hubris quadrant scoring highest on psychoticism and the Depression quadrant scoring highest on neuroticism. Four hierarchical regressions demonstrated the incremental validity of the belief and importance belimp coordinates over the Giant Three personality dimensions in the prediction of academic achievement. CONCLUSIONS. The results are encouraging for belimp theory and complement similarly supportive findings in Petrides (2010b,c). ©2010 The British Psychological Society.
Dowie, Jack
2004-05-01
In many health decision making situations there is a requirement that the effectiveness of interventions, usually their 'clinical' effectiveness, be established, as well as their cost-effectiveness. Often indeed this is effectively a prior requirement for their cost-effectiveness being investigated. If, however, one accepts the ethical argument for using a threshold incremental cost-effectiveness ratio (ICER) for interventions that are more effective but more costly (i.e. fall in the NE quadrant of the cost-effectiveness plane), one should apply the same decision rule in the SW quadrant, where the intervention is less effective but less costly. This implication is present in most standard treatments of cost-effectiveness analysis, including recent stochastic versions, and had gone relatively unquestioned within the discipline until the recent suggestion that the ICER threshold might be 'kinked'. A kinked threshold would, O'Brien et al. argue, better reflect the asymmetrical individual preferences found in empirical studies of consumer's willingness to pay and willingness to accept and justify different decision rules in the NE and SW quadrants. We reject the validity of such asymmetric preferences in the context of public health care decisions and consider and counter the two main 'ethical' objections that probably underlie the asymmetry in this case--the objection to 'taking away' and the objection to being required to undergo treatment that is less effective than no treatment at all. Copyright 2004 John Wiley & Sons, Ltd.
Clinical use of MRI for the evaluation of acute appendicitis during pregnancy.
Patel, Darshan; Fingard, Jordan; Winters, Sean; Low, Gavin
2017-07-01
The purpose of this study was to determine the diagnostic accuracy of MRI for detecting acute appendicitis in pregnancy in a multi-institution study involving general body MR readers with no specific expertise in MR imaging of the pregnant patient. Retrospective review of MRI examinations on PACS in 42 pregnant patients was evaluated for acute right lower quadrant pain. Three fellowship-trained general body radiologists analyzed the MRI examinations in consensus and attempted to localize the appendix, assess for features of appendicitis, and exclude alternative etiologies for the right lower quadrant pain. Of the 42 MRI examinations, the readers noted 6 cases of acute appendicitis, 16 cases of a normal appendix, and 20 cases involving non-visualization of the appendix but where there were no secondary features of acute appendicitis. Based on the surgical data and clinical follow-up, there were 3 true-positive cases, 3 false-positive cases, 34 true-negative cases, and 2 false-negative cases of acute appendicitis on MRI. This yielded an accuracy of 88.1%, sensitivity of 60%, specificity of 91.9%, positive predictive value of 50%, and negative predictive value of 94.4% for the detection of acute appendicitis in the pregnant patient on MRI. Alternative etiologies for the right lower quadrant pain on MRI included torsion of an ovarian dermoid in 1 case and pyelonephritis in 1 case. MRI is an excellent modality for excluding acute appendicitis in pregnant patients presenting with right lower quadrant pain.
Cacciafesta, Vittorio; Sfondrini, Maria Francesca; Melsen, Birte; Scribante, Andrea
2004-08-01
The purpose of this prospective longitudinal randomized study was to compare the clinical performance of recycled brackets with that of new stainless steel brackets (Orthos). Twenty patients treated with fixed appliances were included in the investigation. Using a 'split-mouth' design, the dentition of each patient was divided into four quadrants. In 11 randomly selected patients, the maxillary left and mandibular right quadrants were bonded with recycled brackets, and the remaining quadrants with new stainless steel brackets. In the other nine patients the quadrants were inverted. Three hundred and ten stainless steel brackets were examined: 156 were recycled and the remaining 154 were new. All the brackets were bonded with a self-cured resin-modified glass ionomer (GC Fuji Ortho). The number, cause, and date of bracket failures were recorded over 12 months. Statistical analysis was performed by means of a paired t-test, Kaplan-Meier survival estimates, and the log-rank test. No statistically significant differences were found between: (a) the total bond failure rate of recycled and new stainless steel brackets; (b) the upper and lower arches; (c) the anterior and posterior segments. These findings demonstrate that recycling metallic orthodontic brackets can be of benefit to the profession, both economically and ecologically, as long as the orthodontist is aware of the various aspects of the recycling methods, and that patients are informed about the type of bracket that will be used for their treatment.
Sadat, Umar; Howarth, Simon P S; Usman, Ammara; Tang, Tjun Y; Graves, Martin J; Gillard, Jonathan H
2013-11-01
Inflammation within atheromatous plaques is a known risk factor for plaque vulnerability. This can be detected in vivo on high-resolution magnetic resonance imaging (MRI) using ultrasmall superparamagnetic iron oxide (USPIO) contrast medium. The purpose of this study was to assess the feasibility of performing sequential USPIO studies over a 1-year period. Ten patients with moderate asymptomatic carotid stenosis underwent carotid MRI imaging both before and 36 hours after USPIO infusion at 0, 6, and 12 months. Images were manually segmented into quadrants, and the signal change per quadrant was calculated at these time points. A mixed repeated measures statistical model was used to determine signal change attributable to USPIO uptake over time. All patients remained asymptomatic during the study. The mixed model revealed no statistical difference in USPIO uptake between the 3 time points. Intraclass correlation coefficients revealed a good agreement of quadrant signal pre-USPIO infusion between 0 and 6 months (0.70) and 0 and 12 months (0.70). Good agreement of quadrant signal after USPIO infusion was shown between 0 and 6 months (0.68) and moderate agreement was shown between 0 and 12 months (0.33). USPIO-enhanced sequential MRI of atheromatous carotid plaques is clinically feasible. This may have important implications for future longitudinal studies involving pharmacologic intervention in large patient cohorts. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Randomized clinical trial of virtual reality simulation for laparoscopic skills training.
Grantcharov, T P; Kristiansen, V B; Bendix, J; Bardram, L; Rosenberg, J; Funch-Jensen, P
2004-02-01
This study examined the impact of virtual reality (VR) surgical simulation on improvement of psychomotor skills relevant to the performance of laparoscopic cholecystectomy. Sixteen surgical trainees performed a laparoscopic cholecystectomy on patients in the operating room (OR). The participants were then randomized to receive VR training (ten repetitions of all six tasks on the Minimally Invasive Surgical Trainer-Virtual Reality (MIST-VR)) or no training. Subsequently, all subjects performed a further laparoscopic cholecystectomy in the OR. Both operative procedures were recorded on videotape, and assessed by two independent and blinded observers using predefined objective criteria. Time to complete the procedure, error score and economy of movement score were assessed during the laparoscopic procedure in the OR. No differences in baseline variables were found between the two groups. Surgeons who received VR training performed laparoscopic cholecystectomy significantly faster than the control group (P=0.021). Furthermore, those who had VR training showed significantly greater improvement in error (P=0.003) and economy of movement (P=0.003) scores. Surgeons who received VR simulator training showed significantly greater improvement in performance in the OR than those in the control group. VR surgical simulation is therefore a valid tool for training of laparoscopic psychomotor skills and could be incorporated into surgical training programmes. Copyright 2003 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
Andersen, Steven Arild Wuyts; Foghsgaard, Søren; Konge, Lars; Cayé-Thomasen, Per; Sørensen, Mads Sølvsten
2016-08-01
To establish the effect of self-directed virtual reality (VR) simulation training on cadaveric dissection training performance in mastoidectomy and the transferability of skills acquired in VR simulation training to the cadaveric dissection training setting. Prospective study. Two cohorts of 20 novice otorhinolaryngology residents received either self-directed VR simulation training before cadaveric dissection training or vice versa. Cadaveric and VR simulation performances were assessed using final-product analysis with three blinded expert raters. The group receiving VR simulation training before cadaveric dissection had a mean final-product score of 14.9 (95 % confidence interval [CI] [12.9-16.9]) compared with 9.8 (95% CI [8.4-11.1]) in the group not receiving VR simulation training before cadaveric dissection. This 52% increase in performance was statistically significantly (P < 0.0001). A single dissection mastoidectomy did not increase VR simulation performance (P = 0.22). Two hours of self-directed VR simulation training was effective in increasing cadaveric dissection mastoidectomy performance and suggests that mastoidectomy skills are transferable from VR simulation to the traditional dissection setting. Virtual reality simulation training can therefore be employed to optimize training, and can spare the use of donated material and instructional resources for more advanced training after basic competencies have been acquired in the VR simulation environment. NA. Laryngoscope, 126:1883-1888, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Alahmari, Khalid A.; Sparto, Patrick J; Marchetti, Gregory F.; Redfern, Mark S.; Furman, Joseph M.; Whitney, Susan L.
2017-01-01
We examined outcomes in persons with vestibular disorders after receiving virtual reality based therapy (VRBT) or customized vestibular physical therapy (PT) as an intervention for habituation of dizziness symptoms. Twenty subjects with vestibular disorders received VRBT and 18 received PT. During the VRBT intervention, subjects walked on a treadmill within an immersive virtual grocery store environment, for 6 sessions approximately one week apart. The PT intervention consisted of gaze stabilization, standing balance and walking exercises individually tailored to each subject. Before, one week after, and at 6-months after the intervention, subjects completed self-report and balance performance measures. Before and after each VRBT session, subjects also reported symptoms of nausea, headache, dizziness, and visual blurring. In both groups, significant improvements were noted on the majority of self-report and performance measures one week after the intervention. Subjects maintained improvements on self report and performance measures at 6 months follow up. There were not between group differences. Nausea, headache, dizziness and visual blurring increased significantly during the VRBT sessions, but overall symptoms were reduced at the end of the six-week intervention. While this study did not find a difference in outcomes between PT and VRBT, the mechanism by which subjects with chronic dizziness demonstrated improvement in dizziness and balance function may be different. PMID:24608691
Towards monitoring the englacial fracture state using virtual-reflector seismology
NASA Astrophysics Data System (ADS)
Lindner, F.; Weemstra, C.; Walter, F.; Hadziioannou, C.
2018-04-01
In seismology, coda wave interferometry (CWI) is an effective tool to monitor time-lapse changes using later arriving, multiply scattered coda waves. Typically, CWI relies on an estimate of the medium's impulse response. The latter is retrieved through simple time-averaging of receiver-receiver cross-correlations of the ambient field, i.e. seismic interferometry (SI). In general, the coda are induced by heterogeneities in the Earth. Being comparatively homogeneous, however, ice bodies such as glaciers and ice sheets exhibit little scattering. In addition, the temporal stability of the time-averaged cross-correlations suffers from temporal variations in the distribution and amplitude of the passive seismic sources. Consequently, application of CWI to ice bodies is currently limited. Nevertheless, fracturing and changes in the englacial macroscopic water content alter the bulk elastic properties of ice bodies, which can be monitored with cryoseismological measurements. To overcome the current limited applicability of CWI to ice bodies, we therefore introduce virtual-reflector seismology (VRS). VRS relies on a so-called multidimensional deconvolution (MDD) process of the time-averaged crosscorrelations. The technique results in the retrieval of a medium response that includes virtual reflections from a contour of receivers enclosing the region of interest (i.e., the region to be monitored). The virtual reflections can be interpreted as artificial coda replacing the (lacking) natural scattered coda. Hence, this artificial coda might be exploited for the purpose of CWI. From an implementation point of view, VRS is similar to SI by MDD, which, as its name suggests, also relies on a multidimensional deconvolution process. SI by MDD, however, does not generate additional virtual reflections. Advantageously, both techniques mitigate spurious coda changes associated with temporal variations in the distribution and amplitude of the passive seismic sources. In this work, we apply SI by MDD and VRS to synthetic and active seismic surface-wave data. The active seismic data were acquired on Glacier de la Plaine Morte, Switzerland. We successfully retrieve virtual reflections through the application of VRS to this active seismic data. In application to both synthetic and active seismic data, we show the potential of VRS to monitor time-lapse changes. In addition, we find that SI by MDD allows for a more accurate determination of phase velocity.
Qu, Chao; Ling, Yun; Heynderickx, Ingrid; Brinkman, Willem-Paul
2015-01-01
Bystanders in a real world's social setting have the ability to influence people's beliefs and behavior. This study examines whether this effect can be recreated in a virtual environment, by exposing people to virtual bystanders in a classroom setting. Participants (n = 26) first witnessed virtual students answering questions from an English teacher, after which they were also asked to answer questions from the teacher as part of a simulated training for spoken English. During the experiment the attitudes of the other virtual students in the classroom was manipulated; they could whisper either positive or negative remarks to each other when a virtual student was talking or when a participant was talking. The results show that the expressed attitude of virtual bystanders towards the participants affected their self-efficacy, and their avoidance behavior. Furthermore, the experience of witnessing bystanders commenting negatively on the performance of other students raised the participants' heart rate when it was their turn to speak. Two-way interaction effects were also found on self-reported anxiety and self-efficacy. After witnessing bystanders' positive attitude towards peer students, participants' self-efficacy when answering questions received a boost when bystanders were also positive towards them, and a blow when bystanders reversed their attitude by being negative towards them. Still, inconsistency, instead of consistency, between the bystanders' attitudes towards virtual peers and the participants was not found to result in a larger change in the participants' beliefs. Finally the results also reveal that virtual flattering or destructive criticizing affected the participants' beliefs not only about the virtual bystanders, but also about the neutral teacher. Together these findings show that virtual bystanders in a classroom can affect people's beliefs, anxiety and behavior.
2012-01-01
introduced 2008 - Virtual classroom introduced - Established the DSTC - Received first eLearning award 2003 - Received initial COE...correspondence courses 2009 - Instructor-led courses transitioned to eLearning curriculum 2005 - First eLearning course launched 2011 - SPēD...Managing Risk” from January 9 through May 4, 2012. This eLearning course also included resident sessions at CDSE. Based on feedback from students
Witmer, Matthew T; Parlitsis, George; Patel, Sarju; Kiss, Szilárd
2013-01-01
To compare ultra-widefield fluorescein angiography imaging using the Optos(®) Optomap(®) and the Heidelberg Spectralis(®) noncontact ultra-widefield module. Five patients (ten eyes) underwent ultra-widefield fluorescein angiography using the Optos(®) panoramic P200Tx imaging system and the noncontact ultra-widefield module in the Heidelberg Spectralis(®) HRA+OCT system. The images were obtained as a single, nonsteered shot centered on the macula. The area of imaged retina was outlined and quantified using Adobe(®) Photoshop(®) C5 software. The total area and area within each of four visualized quadrants was calculated and compared between the two imaging modalities. Three masked reviewers also evaluated each quadrant per eye (40 total quadrants) to determine which modality imaged the retinal vasculature most peripherally. Optos(®) imaging captured a total retinal area averaging 151,362 pixels, ranging from 116,998 to 205,833 pixels, while the area captured using the Heidelberg Spectralis(®) was 101,786 pixels, ranging from 73,424 to 116,319 (P = 0.0002). The average area per individual quadrant imaged by Optos(®) versus the Heidelberg Spectralis(®) superiorly was 32,373 vs 32,789 pixels, respectively (P = 0.91), inferiorly was 24,665 vs 26,117 pixels, respectively (P = 0.71), temporally was 47,948 vs 20,645 pixels, respectively (P = 0.0001), and nasally was 46,374 vs 22,234 pixels, respectively (P = 0.0001). The Heidelberg Spectralis(®) was able to image the superior and inferior retinal vasculature to a more distal point than was the Optos(®), in nine of ten eyes (18 of 20 quadrants). The Optos(®) was able to image the nasal and temporal retinal vasculature to a more distal point than was the Heidelberg Spectralis(®), in ten of ten eyes (20 of 20 quadrants). The ultra-widefield fluorescein angiography obtained with the Optos(®) and Heidelberg Spectralis(®) ultra-widefield imaging systems are both excellent modalities that provide views of the peripheral retina. On a single nonsteered image, the Optos(®) Optomap(®) covered a significantly larger total retinal surface area, with greater image variability, than did the Heidelberg Spectralis(®) ultra-widefield module. The Optos(®) captured an appreciably wider view of the retina temporally and nasally, albeit with peripheral distortion, while the ultra-widefield Heidelberg Spectralis(®) module was able to image the superior and inferior retinal vasculature more peripherally. The clinical significance of these findings as well as the area imaged on steered montaged images remains to be determined.
The observatories and instruments of Tycho Brahe
NASA Astrophysics Data System (ADS)
Wolfschmidt, Gudrun
Tycho Brahe (1546-1601) was the most important observational astronomer until the invention of the telescope in 1608. By construction new instruments and devising new observing methods, Tycho succeeded in significantly increasing measurement accuracy: He increased the size of his instruments (e.g. a large wooden quadrant of diameter 5.4 m and a mural quadrant); he used metal and masonry rather than wood; he modified construction techniques to achieve greater stability; to provide shelter from the wind, his instruments were in subterranean nooks; his instruments were permanently and solidly mounted; for better angular readings, he developed new subdivisions and diopters (Tycho used transversals to obtain the greatest possible angular resolution readings. His instrumental sights (diopters) were specially designed to minimize errors); he carefully analysed all the errors (Tycho's aim was to reduce thethe uncertainty to less than one minute of arc); he used fundamental stars for the first time; he preferred measuring equatorial coordinates directly instead of using the zodiacal system, i.e. using the equatorial armillary sphere instead of the zodiacal armillary sphere; he tried a new measuring method with clocks and his mural quadrant (1582) for determining the right ascension; he took atmospheric refraction into account. Most of his high-accuracy instruments have been distroyed. Only two sextants, made by Jost Bürgi and Erasmus Habermel around 1600, still exist in the Narodny Technicky Muzeum (NTM) [National Technical Museum] in Prague. A model of the wooden quadrant is in the old observatory in Copenhagen, in the round tower. But we have good descriptions of the instruments (half circles of 2.3 m radius, quadrants up to 2 m radius including the mural quadrant, sextants up to 1.6 m, armillary spheres of 1.5 m radius and the great equatorial armillary sphere of 2.7 m, triquetrum and celestial globe of 1.5 m) in Tycho's book Astronomiae instauratae mechanica (Wandesburgi 1598, Nuremberg 1602). One of Tycho's instruments in original size was reconstructed in Oldenburg University and in the Steno Museum in Aarhus, Denmark. In Munich, in the Deutsches Museum's permanent astronomy exhibition (opened in 1992), the Uraniborg observatory and its instruments are shown at a scale of 1:10. A similar but larger model (scale 1:5) from the workshop of the Deutsches Museum was given to the Technical Museum in Malmø, Sweden. Tycho's later observatory Stjerneborg can be seen as a reconstruction on the island Hven (Ven/Sweden) with the original foundations for the instruments.
NASA Technical Reports Server (NTRS)
Vaughan, Arthur H. (Inventor)
1993-01-01
A strip imaging wide angle optical system is provided. The optical system is provided with a 'virtual' material stop to avoid aberrational effects inherent in wide angle optical systems. The optical system includes a spherical mirror section for receiving light from a 180 deg strip or arc of a target image. Light received by the spherical mirror section is reflected to a frustoconical mirror section for subsequent rereflection to a row of optical fibers. Each optical fiber transmits a portion of the received light to a detector. The optical system exploits the narrow cone of acceptance associated with optical fibers to substantially eliminate vignetting effects inherent in wide angle systems. Further, the optical system exploits the narrow cone of acceptance of the optical fibers to substantially limit spherical aberration. The optical system is ideally suited for any application wherein a 180 deg strip image need be detected, and is particularly well adapted for use in hostile environments such as in planetary exploration.
Multidisciplinary research in the space sciences
NASA Technical Reports Server (NTRS)
Broecker, W. S.; Flynn, G. W.
1983-01-01
Research activities were carried out in the following areas during this reporting period: (1) astrophysics; (2) climate and atmospheric modeling; and (3) climate applications of earth observations & geological studies. An ultra-low-noise 115 GHz receiver based upon a superconducting tunnel diode mixer has been designed and constructed. The first laboratory tests have yielded spectacular results: a single-sideband noise temperature of 75 K considerably more sensitive than any other receiver at this frequency. The receiver will replace that currently in use on the Columbia-GISS CO Sky Survey telescope. The 1.2 meter millimeter-wave telescope at Columbia University has been used to complete two large-scale surveys of molecular matter in the part of the inner galaxy which is visible from the Northern hemisphere (the first galactic quadrant); one of the distant galaxy and one of the solar neighborhood. The research conducted during the past year in the climate and atmospheric modeling programs has been focused on the development of appropriate atmospheric and upper ocean models, and preliminary applications of these models. Principal models are a one-dimensional radiative-convective model, a three-dimensional global climate model, and an upper ocean model. During the past year this project has focused on development of 2-channel satellite analysis methods and radiative transfer studies in support of multichannel analysis techniques.
Hariharan, S; Hosey, M T; Bernabe, E
2017-05-12
Aims To compare the profile of paediatric patients receiving dental treatment under general anaesthesia (GA) or conscious sedation (CS). A second aim was to explore whether there is an overlap between the two patient groups.Design This service evaluation study was based on sociodemographic and clinical data extracted from clinical records of patients attending dental appointments for GA or CS services at King's College Hospital. Sociodemographic and clinical differences between GA and CS groups were explored using logistic regression models.Results Data from 113 children (58 GA and 55 CS) were analysed. There were differences between groups in terms of age and numbers of quadrants and teeth treated, but not in terms of sex, ethnicity or deprivation scores. In the adjusted model, older children and those having more teeth treated were more likely to be in the GA than in the CS group. An overlap between the GA and CS groups was found, with 50% of children aged four to nine years having two to four teeth treated in both groups.Conclusion Age and number of teeth treated were the main characteristics associated with receiving care under GA or CS. Some overlap between children receiving dental treatment under GA or CS existed despite demographic and clinical differences between both groups.
[Use of dental hygienists in caries prevention].
Morch; Barman, O
1976-09-01
Two caries preventive programs were carried out in the Bergen School Dental Service in order to test various modes of topical application of fluorides and the efficacy of using dental hygienists in the delivery of preventive dental care to school children. In the first program, starting in 1951, A 2% netutral sodium fluoride solution was applied topically four times during one month to one quadrant of the maxillary teeth, the other quadrant serving as control. This series of application was repeated one year later, while the caries registration was followed up until 1956. The results are given in Table 1, comprising 128 children who were 11-12 years old at the start of the study and were still present at the same schools in 1956. A reduction in caries incidence of about 25 per cent was obtained during the five years period. In the second program, beginning in 1963, acid stannous hexafluoride as well as neutral sodium fluoride solutions were used separately in groups of children (7-11 years of age). The total number of children was about 2000. Two groups received four topical applications annually within one month, while in two oher groups the applications were given twice a year. This topical application program was continued for four years. For several reasons pure control groups of children of corresponding age could not be established. Instead the treated groups were compared with children who under supervision brushed their teeth (already from 1964) with 0.5% neutral sodium fluoride solutions five times per year during the school hours. All children received appropriate information and motivation for improved oral hygiene and food habits by the dental hygienists individually in the treated groups and in groups in the comparison group. The results are given in Table 2. The caries reduction obtained per year reached maximally about 40 per cent. This investigation shows that dental hygienists are able to carry out valuable caries preventive work at dental clinics, and it is justified to assign this type of health personnel to separate caries preventive tasks which require little supervision time from the responsible dentists.
Airborne Measurements of Atmospheric Volume Scattering Coefficients in Northern Europe, Summer, 1978
1980-06-01
in the southwestern quadrant . At 1200 GMT there was a 1000 millibar low centered near Genoa with a warm front east and southeast to the Adriatic Sea...occluded front 5’ west of the Irish coast. The track was in the northeast quadrant of the high with northeasterly surlace flow. At 1200 GMT a small 1025...The air mass was maritime polar. The satellite map for 1309 GM F showed thin clouds over western Europa aad heavier cloud cover over eastern ’ur:,pe
Optical synthesizer for a large quadrant-array CCD camera: Center director's discretionary fund
NASA Technical Reports Server (NTRS)
Hagyard, Mona J.
1992-01-01
The objective of this program was to design and develop an optical device, an optical synthesizer, that focuses four contiguous quadrants of a solar image on four spatially separated CCD arrays that are part of a unique CCD camera system. This camera and the optical synthesizer will be part of the new NASA-Marshall Experimental Vector Magnetograph, and instrument developed to measure the Sun's magnetic field as accurately as present technology allows. The tasks undertaken in the program are outlined and the final detailed optical design is presented.
Treatment planning of implants in posterior quadrants.
Jivraj, S; Chee, W
2006-07-08
Differences in anatomy and biomechanics make treatment of posterior quadrants with dental implants substantially different to that of anterior areas. Without implants, when posterior teeth were lost, treatment options included a long span fixed partial denture or a removable prosthesis, especially when no terminal abutment was available. Today, with the use of implants, options are available that allow preservation of unrestored teeth.(1) When teeth are missing, implant supported restorations can be considered the treatment of choice from the perspective of occlusal support, preservation of adjacent teeth and avoidance of a removable partial denture.
NASA Astrophysics Data System (ADS)
Perrone, Sandro; Volpe, Giovanni; Petrov, Dmitri
2008-10-01
We propose a technique that permits one to increase by one order of magnitude the detection range of position sensing for the photonic force microscope with quadrant photodetectors (QPDs). This technique takes advantage of the unavoidable cross-talk between output signals of the QPD and does not assume that the output signals are linear in the probe displacement. We demonstrate the increase in the detection range from 150 to 1400 nm for a trapped polystyrene sphere with radius of 300 nm as probe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perrone, Sandro; Volpe, Giovanni; Petrov, Dmitri
2008-10-15
We propose a technique that permits one to increase by one order of magnitude the detection range of position sensing for the photonic force microscope with quadrant photodetectors (QPDs). This technique takes advantage of the unavoidable cross-talk between output signals of the QPD and does not assume that the output signals are linear in the probe displacement. We demonstrate the increase in the detection range from 150 to 1400 nm for a trapped polystyrene sphere with radius of 300 nm as probe.
Perrone, Sandro; Volpe, Giovanni; Petrov, Dmitri
2008-10-01
We propose a technique that permits one to increase by one order of magnitude the detection range of position sensing for the photonic force microscope with quadrant photodetectors (QPDs). This technique takes advantage of the unavoidable cross-talk between output signals of the QPD and does not assume that the output signals are linear in the probe displacement. We demonstrate the increase in the detection range from 150 to 1400 nm for a trapped polystyrene sphere with radius of 300 nm as probe.
Monitoring the englacial fracture state using virtual-reflector seismology
NASA Astrophysics Data System (ADS)
Lindner, F.; Weemstra, C.; Walter, F.; Hadziioannou, C.
2017-12-01
Fracturing and changes in the englacial macroscopic water content change the elastic bulk properties of ice bodies. Small seismic velocity variations, resulting from such changes, can be measured using a technique called coda-wave interferometry. Here, coda refers to the later-arriving, multiply scattered waves. Often, this technique is applied to so-called virtual-source responses, which can be obtained using seismic interferometry (a simple crosscorrelation process). Compared to other media (e.g., the Earth's crust), however, ice bodies exhibit relatively little scattering. This complicates the application of coda-wave interferometry to the retrieved virtual-source responses. In this work, we therefore investigate the applicability of coda-wave interferometry to virtual-source responses obtained using two alternative seismic interferometric techniques, namely, seismic interferometry by multidimensional deconvolution (SI by MDD), and virtual-reflector seismology (VRS). To that end, we use synthetic data, as well as active-source glacier data acquired on Glacier de la Plaine Morte, Switzerland. Both SI by MDD and VRS allow the retrieval of more accurate virtual-source responses. In particular, the dependence of the retrieved virtual-source responses on the illumination pattern is reduced. We find that this results in more accurate glacial phase-velocity estimates. In addition, VRS introduces virtual reflections from a receiver contour (partly) enclosing the medium of interest. By acting as a sort of virtual reverberation, the coda resulting from the application of VRS significantly increases seismic monitoring capabilities, in particular in cases where natural scattering coda is not available.
Environmental continuous air monitor inlet with combined preseparator and virtual impactor
Rodgers, John C [Santa Fe, NM
2007-06-19
An inlet for an environmental air monitor is described wherein a pre-separator interfaces with ambient environment air and removes debris and insects commonly associated with high wind outdoors and a deflector plate in communication with incoming air from the pre-separator stage, that directs the air radially and downward uniformly into a plurality of accelerator jets located in a manifold of a virtual impactor, the manifold being cylindrical and having a top, a base, and a wall, with the plurality of accelerator jets being located in the top of the manifold and receiving the directed air and accelerating directed air, thereby creating jets of air penetrating into the manifold, where a major flow is deflected to the walls of the manifold and extracted through ports in the walls. A plurality of receiver nozzles are located in the base of the manifold coaxial with the accelerator jets, and a plurality of matching flow restrictor elements are located in the plurality of receiver nozzles for balancing and equalizing the total minor flow among all the plurality of receiver nozzles, through which a lower, fractional flow extracts large particle constituents of the air for collection on a sample filter after passing through the plurality of receiver nozzles and the plurality of matching flow restrictor elements.
Berman, Anne H; Biguet, Gabriele; Stathakarou, Natalia; Westin-Hägglöf, Beata; Jeding, Kerstin; McGrath, Cormac; Zary, Nabil; Kononowicz, Andrzej A
2017-10-01
The purpose of this article is to explore learners' perceptions of using virtual patients in a behavioral medicine Massive Open Online Course (MOOCs) and thereby describe innovative ways of disseminating knowledge in health-related areas. A 5-week MOOC on behavioral medicine was hosted on the edX platform. The authors developed two branched virtual patients consisting of video recordings of a live standardized patient, with multiple clinical decision points and narration unfolding depending on learners' choices. Students interacted with the virtual patients to treat stress and sleep problems. Answers to the exit survey and participant comments from the discussion forum were analyzed qualitatively and quantitatively. In total, 19,236 participants enrolled in the MOOC, out of which 740 received the final certificate. The virtual patients were completed by 2317 and 1640 participants respectively. Among survey respondents (n = 442), 83.1% agreed that the virtual patient exercise was helpful. The qualitative analysis resulted in themes covering what it was like to work with the virtual patient, with subthemes on learner-centered education, emotions/eustress, game comparisons, what the participants learned, what surprised them, how confident participants felt about applying interventions in practice, suggestions for improvement, and previous experiences of virtual patients. Students were enthusiastic about interacting with the virtual patients as a means to apply new knowledge about behavioral medicine interventions. The most common suggestion was to incorporate more interactive cases with various levels of complexity. Further research should include patient outcomes and focus on interprofessional aspects of learning with virtual patients in a MOOC.
Li, Zhen; Han, Xiu-Guo; Sheng, Jing; Ma, Shao-Jun
2016-05-01
To evaluate the effectiveness of virtual reality interventions for improving balance in people after stroke. Systematic review and meta-analysis of randomized controlled trials. Studies were obtained by searching the following databases: MEDLINE, CINAHL, EMBASE, Web of Science and CENTRAL. Two reviewers assessed studies for inclusion, extracted data and assessed trial quality. Sixteen studies involving 428 participants were included. People who received virtual reality interventions showed marked improvements in Berg Balance Scale (mean difference: 1.46, 95% confidence interval: 0.09-2.83, P<0.05, I²=0%) and Timed Up and Go Test (mean difference: -1.62, 95% confidence interval: -3.07- -0.16, P<0.05, I²=24%) compared with controls. This meta-analysis of randomized controlled trials supports the use of virtual reality to improve balance after stroke. © The Author(s) 2015.
Wong, Kit Fai
2011-01-01
Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time. PMID:21383930
Virtual Diving in the Underwater Archaeological Site of Cala Minnola
NASA Astrophysics Data System (ADS)
Bruno, F.; Lagudi, A.; Barbieri, L.; Muzzupappa, M.; Mangeruga, M.; Pupo, F.; Cozza, M.; Cozza, A.; Ritacco, G.; Peluso, R.; Tusa, S.
2017-02-01
The paper presents the application of the technologies and methods defined in the VISAS project for the case study of the underwater archaeological site of Cala Minnola located in the island of Levanzo, in the archipelago of the Aegadian Islands (Sicily, Italy). The VISAS project (http://visas-project.eu) aims to improve the responsible and sustainable exploitation of the Underwater Cultural Heritage by means the development of new methods and technologies including an innovative virtual tour of the submerged archaeological sites. In particular, the paper describes the 3D reconstruction of the underwater archaeological site of Cala Minnola and focus on the development of the virtual scene for its visualization and exploitation. The virtual dive of the underwater archaeological site allows users to live a recreational and educational experience by receiving historical, archaeological and biological information about the submerged exhibits, the flora and fauna of the place.
A review of haptic simulator for oral and maxillofacial surgery based on virtual reality.
Chen, Xiaojun; Hu, Junlei
2018-06-01
Traditional medical training in oral and maxillofacial surgery (OMFS) may be limited by its low efficiency and high price due to the shortage of cadaver resources. With the combination of visual rendering and feedback force, surgery simulators become increasingly popular in hospitals and medical schools as an alternative to the traditional training. Areas covered: The major goal of this review is to provide a comprehensive reference source of current and future developments of haptic OMFS simulators based on virtual reality (VR) for relevant researchers. Expert commentary: Visual rendering, haptic rendering, tissue deformation, and evaluation are key components of haptic surgery simulator based on VR. Compared with traditional medical training, virtual and tactical fusion of virtual environment in surgery simulator enables considerably vivid sensation, and the operators have more opportunities to practice surgical skills and receive objective evaluation as reference.
Network testbed creation and validation
Thai, Tan Q.; Urias, Vincent; Van Leeuwen, Brian P.; Watts, Kristopher K.; Sweeney, Andrew John
2017-03-21
Embodiments of network testbed creation and validation processes are described herein. A "network testbed" is a replicated environment used to validate a target network or an aspect of its design. Embodiments describe a network testbed that comprises virtual testbed nodes executed via a plurality of physical infrastructure nodes. The virtual testbed nodes utilize these hardware resources as a network "fabric," thereby enabling rapid configuration and reconfiguration of the virtual testbed nodes without requiring reconfiguration of the physical infrastructure nodes. Thus, in contrast to prior art solutions which require a tester manually build an emulated environment of physically connected network devices, embodiments receive or derive a target network description and build out a replica of this description using virtual testbed nodes executed via the physical infrastructure nodes. This process allows for the creation of very large (e.g., tens of thousands of network elements) and/or very topologically complex test networks.
Training multitasking in a virtual supermarket: a novel intervention after stroke.
Rand, Debbie; Weiss, Patrice L Tamar; Katz, Noomi
2009-01-01
To explore the potential of the VMall, a virtual supermarket running on a video-capture virtual reality system, as an intervention tool for people who have multitasking deficits after stroke. Poststroke, 4 participants received ten 60-min sessions over 3 weeks using the VMall. The intervention focused on improving multitasking while the participant was engaged in a virtual shopping task. Instruments included the Multiple Errands Test-Hospital Version (MET-HV) in a real mall and in the VMall. Participants achieved improvements ranging from 20.5% to 51.2% for most of the MET-HV measures performed in a real shopping mall and in the VMall. The data support the VMall's potential as a motivating and effective intervention tool for the rehabilitation of people poststroke who have multitasking deficits during the performance of daily tasks. However, because the sample was small, additional intervention studies with the VMall should be conducted.
Network testbed creation and validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thai, Tan Q.; Urias, Vincent; Van Leeuwen, Brian P.
Embodiments of network testbed creation and validation processes are described herein. A "network testbed" is a replicated environment used to validate a target network or an aspect of its design. Embodiments describe a network testbed that comprises virtual testbed nodes executed via a plurality of physical infrastructure nodes. The virtual testbed nodes utilize these hardware resources as a network "fabric," thereby enabling rapid configuration and reconfiguration of the virtual testbed nodes without requiring reconfiguration of the physical infrastructure nodes. Thus, in contrast to prior art solutions which require a tester manually build an emulated environment of physically connected network devices,more » embodiments receive or derive a target network description and build out a replica of this description using virtual testbed nodes executed via the physical infrastructure nodes. This process allows for the creation of very large (e.g., tens of thousands of network elements) and/or very topologically complex test networks.« less
Virtual Visits for Acute, Nonurgent Care: A Claims Analysis of Episode-Level Utilization.
Gordon, Aliza S; Adamson, Wallace C; DeVries, Andrea R
2017-02-17
Expansion of virtual health care-real-time video consultation with a physician via the Internet-will continue as use of mobile devices and patient demand for immediate, convenient access to care grow. The objective of the study is to analyze the care provided and the cost of virtual visits over a 3-week episode compared with in-person visits to retail health clinics (RHC), urgent care centers (UCC), emergency departments (ED), or primary care physicians (PCP) for acute, nonurgent conditions. A cross-sectional, retrospective analysis of claims from a large commercial health insurer was performed to compare care and cost of patients receiving care via virtual visits for a condition of interest (sinusitis, upper respiratory infection, urinary tract infection, conjunctivitis, bronchitis, pharyngitis, influenza, cough, dermatitis, digestive symptom, or ear pain) matched to those receiving care for similar conditions in other settings. An episode was defined as the index visit plus 3 weeks following. Patients were children and adults younger than 65 years of age without serious chronic conditions. Visits were classified according to the setting where the visit occurred. Care provided was assessed by follow-up outpatient visits, ED visits, or hospitalizations; laboratory tests or imaging performed; and antibiotic use after the initial visit. Episode costs included the cost of the initial visit, subsequent medical care, and pharmacy. A total of 59,945 visits were included in the analysis (4635 virtual visits and 55,310 nonvirtual visits). Virtual visit episodes had similar follow-up outpatient visit rates (28.09%) as PCP (28.10%, P=.99) and RHC visits (28.59%, P=.51). During the episode, lab rates for virtual visits (12.56%) were lower than in-person locations (RHC: 36.79%, P<.001; UCC: 39.01%, P<.001; ED: 53.15%, P<.001; PCP: 37.40%, P<.001), and imaging rates for virtual visits (6.62%) were typically lower than in-person locations (RHC: 5.97%, P=.11; UCC: 8.77%, P<.001; ED: 43.06%, P<.001; PCP: 11.26%, P<.001). RHC, UCC, ED, and PCP were estimated to be $36, $153, $1735, and $162 more expensive than virtual visit episodes, respectively, including medical and pharmacy costs. Virtual care appears to be a low-cost alternative to care administered in other settings with lower testing rates. The similar follow-up rate suggests adequate clinical resolution and that patients are not using virtual visits as a first step before seeking in-person care. ©Aliza S Gordon, Wallace C Adamson, Andrea R DeVries. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 17.02.2017.
Embodying self-compassion within virtual reality and its effects on patients with depression
Falconer, Caroline J.; Rovira, Aitor; King, John A.; Gilbert, Paul; Antley, Angus; Fearon, Pasco; Ralph, Neil; Slater, Mel
2016-01-01
Background Self-criticism is a ubiquitous feature of psychopathology and can be combatted by increasing levels of self-compassion. However, some patients are resistant to self-compassion. Aims To investigate whether the effects of self-identification with virtual bodies within immersive virtual reality could be exploited to increase self-compassion in patients with depression. Method We developed an 8-minute scenario in which 15 patients practised delivering compassion in one virtual body and then experienced receiving it from themselves in another virtual body. Results In an open trial, three repetitions of this scenario led to significant reductions in depression severity and self-criticism, as well as to a significant increase in self-compassion, from baseline to 4-week follow-up. Four patients showed clinically significant improvement. Conclusions The results indicate that interventions using immersive virtual reality may have considerable clinical potential and that further development of these methods preparatory to a controlled trial is now warranted. Declaration of interest None. Copyright and usage © The Royal College of Psychiatrists 2016. This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY) licence. PMID:27703757
To Tweet or Not to Tweet... That Is the Question
ERIC Educational Resources Information Center
Gittner, Alastair
2011-01-01
Twitter is a website that enables one to send and receive short text messages to and from another person. It is an easy way of communicating at virtually no cost with friends and family, a brilliant way of getting up-to-date news, teaching resources and ideas, and the means of receiving a really useful, free, hour's CPD each week, through…
Teaching with technology: automatically receiving information from the internet and web.
Wink, Diane M
2010-01-01
In this bimonthly series, the author examines how nurse educators can use the Internet and Web-based computer technologies such as search, communication, and collaborative writing tools, social networking and social bookmarking sites, virtual worlds, and Web-based teaching and learning programs. This article presents information and tools related to automatically receiving information from the Internet and Web.
Marshall, Jane; Booth, Tracey; Devane, Niamh; Galliers, Julia; Greenwood, Helen; Hilari, Katerina; Talbot, Richard; Wilson, Stephanie; Woolf, Celia
2016-01-01
This study evaluated an intervention for people with aphasia delivered in a novel virtual reality platform called EVA Park. EVA Park contains a number of functional and fantastic locations and allows for interactive communication between multiple users. Twenty people with aphasia had 5 weeks' intervention, during which they received daily language stimulation sessions in EVA Park from a support worker. The study employed a quasi randomised design, which compared a group that received immediate intervention with a waitlist control group. Outcome measures explored the effects of intervention on communication and language skills, communicative confidence and feelings of social isolation. Compliance with the intervention was also explored through attrition and usage data. There was excellent compliance with the intervention, with no participants lost to follow up and most (18/20) receiving at least 88% of the intended treatment dose. Intervention brought about significant gains on a measure of functional communication. Gains were achieved by both groups of participants, once intervention was received, and were well maintained. Changes on the measures of communicative confidence and feelings of social isolation were not achieved. Results are discussed with reference to previous aphasia therapy findings.
Marshall, Jane; Booth, Tracey; Devane, Niamh; Galliers, Julia; Greenwood, Helen; Hilari, Katerina; Talbot, Richard; Wilson, Stephanie; Woolf, Celia
2016-01-01
Introduction This study evaluated an intervention for people with aphasia delivered in a novel virtual reality platform called EVA Park. EVA Park contains a number of functional and fantastic locations and allows for interactive communication between multiple users. Twenty people with aphasia had 5 weeks’ intervention, during which they received daily language stimulation sessions in EVA Park from a support worker. The study employed a quasi randomised design, which compared a group that received immediate intervention with a waitlist control group. Outcome measures explored the effects of intervention on communication and language skills, communicative confidence and feelings of social isolation. Compliance with the intervention was also explored through attrition and usage data. Results There was excellent compliance with the intervention, with no participants lost to follow up and most (18/20) receiving at least 88% of the intended treatment dose. Intervention brought about significant gains on a measure of functional communication. Gains were achieved by both groups of participants, once intervention was received, and were well maintained. Changes on the measures of communicative confidence and feelings of social isolation were not achieved. Results are discussed with reference to previous aphasia therapy findings. PMID:27518188
Bright, C J; Rea, D W; Francis, A; Feltbower, R G
2016-10-01
UK breast cancer incidence rates suggest that upper outer quadrant (UOQ) cancers have risen disproportionately compared with other areas over time. We aimed to provide a comparison of the trend in quadrant-specific breast cancer incidence between the United States (US) and England, and determine whether a disproportionate UOQ increase is present. Surveillance Epidemiology and End Results (SEER) cancer registry data were obtained on 630,007 female breast cancers from 1975 to 2013. English cancer registry data were obtained on 1,121,134 female breast cancers from 1979 to 2013. Temporal incidence changes were analysed using negative binomial regression. Interaction terms determined whether incidence changes were similar between sites. English breast cancer incidence in the UOQ rose significantly from 13% to 28% from 1979 to 2013 whereas no significant increase was observed among SEER data. The significant interaction between quadrant and year of diagnosis (p<0.001) in both SEER and English data indicates that breast cancer incidence in each quadrant changed at a different rate. Incidence in the UOQ rose disproportionately compared to the nipple (SEER IRR=0.81, p<0.001; England IRR=0.78, p<0.001) and axillary tail (SEER IRR=0.87, p=0.018; England IRR=0.69, p<0.001) in both SEER and England. In addition, incidence rose disproportionately in the UOQ compared to non-site-specific tumours in England (Overlapping lesions IRR=0.81, p=0.002; NOS IRR=0.78, p<0.001). The proportion of non-site-specific tumours was substantially higher in England than SEER throughout the study period (62% in England; 39% in SEER). Breast cancer incidence in the UOQ increased disproportionately compared to non-site-specific tumours in England but not in SEER, likely due to the decrease in non-site-specific tumours observed in England over time. There may be real differences in incidence between the two countries, possibly due to differences in aetiology, but is much more likely to be an artefact of changing data collection methods and improvements in site coding in either country. Copyright © 2016 Elsevier Ltd. All rights reserved.
Israel's Quadrant: Weeping, Laughing, and the Measures of the Stars
NASA Astrophysics Data System (ADS)
Locci, A. A.
2011-06-01
In the Jewish culture of the Middle Ages, the astral bodies were constantly given a special attention. They were deeply admired in religious poetry, and studied and observed in scientific and technical works. In an elegy of an anonymous poet of the 11th century, which is usually read in the celebrations of the 9th day of Ab, constellations and stars share the grief for the destruction of the temple of Jerusalem. Like the Israel Tribes, all constellations are said to weep; Pleiades and Orion are said to darken their face, the Scales turn asymmetrical, the pan of death overrides the pan of life; Scorpio is scared and trembles, Sagittarius turns his face back. Jacob ben Machir ibn Tibbon, born in Marseille in 1236, was physician, mathematician, and astronomer. He translated Euclides' Elements, the Treatise of the Armillar Sphere by Qusta ibn Luqa, the Treatise on the Astrolabe by abu al-Kasim Ahmad ibn al Saffar, and works of Ptolemy, Averroes, and Aristoteles. His most important work is the short treatise Rova' Israel ("Israel's Quadrant") which he later translated in Latin with the help of Armengaud from Blaise. In the first chapter, he discusses the Sun risings, the days of the month, the place of the Sun in the sky, and the lunar motion. In the second chapter, he discusses the relations between sunrise and sunset, between moonrise and moonset, and between solar year and lunar month. In the following chapters, he illustrates a technical device which he had developed and which he designates "Israel's Quadrant". This instrument could be used both for the sky and for the Earth, since it allowed to survey and measure the elevation of the stars, the elevation of terrestrial reliefs, and terrestrial horizontal distances. The quadrant is flat, and its area is that of a quarter of a circumference. This instrument was very versatile, it also allowed to calculate hours and time, and this favoured its exceptional diffusion. Thus, its name, "quadrant", was transferred to the visible surface of the clock, notwithstanding the fact that its shape is that of a complete circumference.
Living on the edge: roads and edge effects on small mammal populations.
Fuentes-Montemayor, Elisa; Cuarón, Alfredo D; Vázquez-Domínguez, Ella; Benítez-Malvido, Julieta; Valenzuela-Galván, David; Andresen, Ellen
2009-07-01
1. Roads may affect wildlife populations through habitat loss and disturbances, as they create an abrupt linear edge, increasing the proportion of edge exposed to a different habitat. Three types of edge effects have been recognized: abiotic, direct biotic, and indirect biotic. 2. We explored the direct biotic edge effects of 3- to 4-m wide roads, and also a previously unrecognized type of edge effect: social. We live-trapped two threatened endemic rodents from Cozumel Island (Oryzomys couesi cozumelae and Reithrodontomys spectabilis) in 16 plots delimited by roads on two sides, to compare edge effects between two adjacent edges (corners), single-edge and interior forest, on life history and social variables. 3. No significant edge effects were observed on the life-history variables, with the exception of differences in body condition between males and females of O. c. cozumelae near edges. Both species showed significant and contrasting effects on their social variables. 4. O. c. cozumelae was distributed according to its age and sex: the proportion of adults and males was higher in interior than near edges, while juveniles and females were more abundant near edges. More nonreproductive females were present in corners than in single-edge and interior, while the opposite distribution was observed for nonreproductive males. 5. The distribution of R. spectabilis was related to its age and reproductive condition, but not to its sex. The proportion of adults was significantly higher in corners, while juveniles were only caught in single-edge and interior quadrants. The proportion of reproductive individuals was higher in edge than interior quadrants, while reproductive females were only present in edge quadrants. 6. We found significant differences between the quadrants with the greatest edge exposure in comparison with other quadrants. The social edge effects we identified complement the typology of edge effects recognized in ecological literature. Our study provides insight into the effects that sharp road edges have on biological and social characteristics of small mammal populations, highlighting how such effects vary among species. Our findings have important conservation implications for these threatened species, but are also applicable in a broader context wherever there are abrupt edges caused by linear landscape features.
Virtual reality helmet display quality influences the magnitude of virtual reality analgesia.
Hoffman, Hunter G; Seibel, Eric J; Richards, Todd L; Furness, Thomas A; Patterson, David R; Sharar, Sam R
2006-11-01
Immersive Virtual Reality (VR) distraction can be used in addition to traditional opioids to reduce procedural pain. The current study explored whether a High-Tech-VR helmet (ie, a 60-degree field-of-view head-mounted display) reduces pain more effectively than a Low-Tech-VR helmet (a 35-degree field-of-view head-mounted display). Using a double-blind between-groups design, 77 healthy volunteers (no patients) aged 18-23 were randomly assigned to 1 of 3 groups. Each subject received a brief baseline thermal pain stimulus, and the same stimulus again minutes later while in SnowWorld using a Low-Tech-VR helmet (Group 1), using a High-Tech-VR helmet (Group 2), or receiving no distraction (Group 3, control group). Each participant provided subjective 0-10 ratings of cognitive, sensory, and affective components of pain, and amount of fun during the pain stimulus. Compared to the Low-Tech-VR helmet group, subjects in the High-Tech-VR helmet group reported 34% more reduction in worst pain (P < .05), 46% more reduction in pain unpleasantness (P = .001), 29% more reduction in "time spent thinking about pain" (P < .05), and 32% more fun during the pain stimulus in VR (P < .05). Only 29% of participants in the Low-Tech helmet group, as opposed to 65% of participants in the High-Tech-VR helmet group, showed a clinically significant reduction in pain intensity during virtual reality. These results highlight the importance of using an appropriately designed VR helmet to achieve effective VR analgesia (see ). Pain during medical procedures (eg, burn wound care) is often excessive. Adjunctive virtual reality distraction can substantially reduce procedural pain. The results of the present study show that a higher quality VR helmet was more effective at reducing pain than a lower quality VR helmet.
Effect of Virtual Reality on Cognition in Stroke Patients
Kim, Bo Ryun; Kim, Lee Suk; Park, Ji Young
2011-01-01
Objective To investigate the effect of virtual reality on the recovery of cognitive impairment in stroke patients. Method Twenty-eight patients (11 males and 17 females, mean age 64.2) with cognitive impairment following stroke were recruited for this study. All patients were randomly assigned to one of two groups, the virtual reality (VR) group (n=15) or the control group (n=13). The VR group received both virtual reality training and computer-based cognitive rehabilitation, whereas the control group received only computer-based cognitive rehabilitation. To measure, activity of daily living cognitive and motor functions, the following assessment tools were used: computerized neuropsychological test and the Tower of London (TOL) test for cognitive function assessment, Korean-Modified Barthel index (K-MBI) for functional status evaluation, and the motricity index (MI) for motor function assessment. All recruited patients underwent these evaluations before rehabilitation and four weeks after rehabilitation. Results The VR group showed significant improvement in the K-MMSE, visual and auditory continuous performance tests (CPT), forward digit span test (DST), forward and backward visual span tests (VST), visual and verbal learning tests, TOL, K-MBI, and MI scores, while the control group showed significant improvement in the K-MMSE, forward DST, visual and verbal learning tests, trail-making test-type A, TOL, K-MBI, and MI scores after rehabilitation. The changes in the visual CPT and backward VST in the VR group after rehabilitation were significantly higher than those in the control group. Conclusion Our findings suggest that virtual reality training combined with computer-based cognitive rehabilitation may be of additional benefit for treating cognitive impairment in stroke patients. PMID:22506159
Adapting the balanced scorecard for mental health and addictions: an inpatient example.
Lin, Elizabeth; Durbin, Janet
2008-05-01
The Balanced Scorecard (BSC) is a performance-monitoring framework that originated in the business sector but has more recently been applied to health services. The province of Ontario is using the BSC approach to monitor quality of inpatient care in five service areas. Feasibility of the scorecard framework for each area has been assessed using a standard approach. This paper reports results of the feasibility study for the mental health sector, focusing on three issues: framework relevance, underlying strategic goals and indicator selection. Based on a literature review and extensive stakeholder input, the BSC quadrant structure was recommended with some modifications, and indicators were selected that aligned with provincial mental health reform policy goals. The mental health report has completed two cycles of reporting, and has received good support from the field. Copyright © 2008 Longwoods Publishing.
Primary lymphoma of appendix presenting as acute appendicitis: A case report.
Caristo, Giuseppe; Griseri, Guido; Fornaro, Rosario; Langone, Antonio; Franceschi, Angelo; Errigo, Veronica; Ferrari, Cecilia; Casaccia, Marco; Frascio, Marco; Schirru, Angelo
2018-05-07
Primary lymphomas of appendix are extremely rare tumors. The incidence is 0.015% of all gastrointestinal lymphomas. We present a case of a 75 year-old male patient who presented with acute abdominal pain in the lower right quadrant and fever. The patient received laparotomic appendectomy. The definitive histopathological examination revealed the presence of diffuse large cell B-lymphoma of the appendix. The neoplasms of appendix usually manifest clinically with sign and symptoms of acute appendicitis from luminal obstruction (30-50%). Preoperative diagnosis is difficult and often occurs through histopathological examination. Primary appendiceal lymphoma is rare and there are no clear guidelines for therapy. Primary surgical resection followed by post-operative chemotherapy showed high efficacy. The histopathological examination of all appendectomy is essential. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
PN-CCD camera for XMM: performance of high time resolution/bright source operating modes
NASA Astrophysics Data System (ADS)
Kendziorra, Eckhard; Bihler, Edgar; Grubmiller, Willy; Kretschmar, Baerbel; Kuster, Markus; Pflueger, Bernhard; Staubert, Ruediger; Braeuninger, Heinrich W.; Briel, Ulrich G.; Meidinger, Norbert; Pfeffermann, Elmar; Reppin, Claus; Stoetter, Diana; Strueder, Lothar; Holl, Peter; Kemmer, Josef; Soltau, Heike; von Zanthier, Christoph
1997-10-01
The pn-CCD camera is developed as one of the focal plane instruments for the European photon imaging camera (EPIC) on board the x-ray multi mirror (XMM) mission to be launched in 1999. The detector consists of four quadrants of three pn-CCDs each, which are integrated on one silicon wafer. Each CCD has 200 by 64 pixels (150 micrometer by 150 micrometers) with 280 micrometers depletion depth. One CCD of a quadrant is read out at a time, while the four quadrants can be processed independently of each other. In standard imaging mode the CCDs are read out sequentially every 70 ms. Observations of point sources brighter than 1 mCrab will be effected by photon pile- up. However, special operating modes can be used to observe bright sources up to 150 mCrab in timing mode with 30 microseconds time resolution and very bright sources up to several crab in burst mode with 7 microseconds time resolution. We have tested one quadrant of the EPIC pn-CCD camera at line energies from 0.52 keV to 17.4 keV at the long beam test facility Panter in the focus of the qualification mirror module for XMM. In order to test the time resolution of the system, a mechanical chopper was used to periodically modulate the beam intensity. Pulse periods down to 0.7 ms were generated. This paper describes the performance of the pn-CCD detector in timing and burst readout modes with special emphasis on energy and time resolution.
Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea
2015-12-01
Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP). Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed. Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD. PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Tran, Amy; Pio, Betty S; Khatibi, Bahareh; Czernin, Johannes; Phelps, Michael E; Silverman, Daniel H S
2005-09-01
Extraaxillary metastases (i.e., in the absence of axillary involvement) are more likely to develop in patients with inner-quadrant (IQ) breast cancer than in patients with outer-quadrant (OQ) primary tumors. The relative difficulty of identifying extraaxillary metastases may lead to understaging of cancer in these patients. This study examined whether (18)F-FDG PET findings were differentially associated with the location of primary tumors, and with long-term prognosis, in IQ and OQ patients. Follow-up data were obtained for 141 patients whose breast cancer was staged by PET and who were documented to have IQ (n = 42) or OQ (n = 99) primaries. Results were stratified according to PET findings consistent with different metastatic patterns. Data were further analyzed with respect to disease outcome after a mean 3-y follow-up period. Among IQ patients, progressive disease was identified in 26.1%, compared with 13.1% of OQ patients, for a relative risk (RR) of 2.0. Of patients with PET findings of isolated extraaxillary metastases, 36.1% had progressive disease, compared with 10.7% of other patients (RR = 3.4), and 61.9% of IQ patients had isolated extraaxillary metastases identified on PET, compared with 10.1% of OQ patients (RR = 6.1). IQ patients demonstrated a 6-fold greater frequency of PET findings of isolated extraaxillary metastasis, and such findings were associated with triple the risk for disease progression. Patients with IQ tumors could be vulnerable to understaging with conventional staging approaches and may particularly benefit from PET during the staging process.
Cui, Shan-shan; Zou, Yan-hong; Li, Qian; Li, Li-na; Zhang, Ning; Liu, Xi-pu
2014-12-01
To assess the agreement between gonioscopy and ultrasound biomicroscopy (UBM) in detecting angle closure in Chinese patients with shallow anterior chamber. An observational comparative study of the two different examination methods was conducted. Patients with normal intraocular pressure and temporal peripheral anterior chamber depth less than a quarter of corneal thickness based on slit lamp examination were included in this study from December 2007 to May 2009 in the outpatient clinic of First Hospital of Tsinghua University. Gonioscopy was performed with a Goldman goniolens in dark room first and followed by full beam light and indentation. If the filtering trabecular meshwork was invisible or any peripheral anterior synechia was found, that quadrant of the angle was considered closed. UBM was first undertaken in a darkened room then repeated with normal room lighting. If iridotrabecular apposition was showed, that quadrant of the angle was considered closed. The status of angle closure of each quadrant with different methods was recorded. 85 eyes of 46 patients were included in this study. The agreement between gonioscopy and UBM was poor (Κ<0.4) with Kappa analysis in both dark and light conditions in each quadrant. The accordance of agreement between gonioscopy and UBM was hardly affected by age or sex, while in dark condition, eyes with deeper anterior chamber (P=0.005) or plateau iris configuration tended to produce different results (P=0.075) in the 2 methods. Gonioscopy and UBM are both indispensable methods for detecting angle closure, neither can completely replace the other.
Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.
2010-01-01
Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039
About the role of the source terms on the spatial structure of the wave field in hurricanes
NASA Astrophysics Data System (ADS)
Osuna, P.; Esquivel-Trava, B.; Ocampo-Torres, F. J.
2012-04-01
A numerical experiment has been carried out in order to study the structure of the wave field during hurricane conditions. High resolution wind data for a hurricane were obtained by the use of a Holland type asymmetric model. The third generation wind-wave model SWAN has been used in this study. A reference framework for the structure of the wave field in hurricanes is obtained using the NDBC directional buoy database in the Caribbean Sea and the Gulf of Mexico. This observational reference is used to assess the ability of the model to reproduce the complexity of the wave field observed in hurricanes. It is found that the numerical results are in good agreement with the observed wave field in the hurricane: higher waves are in the right forward quadrant of the hurricane, where the spectral shape tends to become uni-modal. More complex spectral shapes are observed in the rear quadrants of the hurricane, where a tendency of the spectra to become multi-modal is observed. As pointed out by other authors, the wave field in the hurricane is dominated by swell propagating at significant angles to the local wind directions, except on a small region between the first and fourth quadrants. A deeper insight on the role of the physics that controls the evolution of the wave field is assessed by the analysis of the effect of the source terms computed by the wave model in the four quadrants of the hurricane. This is a contribution to the project CB-168173, funded by CONACYT.
An algorithm for calculating minimum Euclidean distance between two geographic features
NASA Astrophysics Data System (ADS)
Peuquet, Donna J.
1992-09-01
An efficient algorithm is presented for determining the shortest Euclidean distance between two features of arbitrary shape that are represented in quadtree form. These features may be disjoint point sets, lines, or polygons. It is assumed that the features do not overlap. Features also may be intertwined and polygons may be complex (i.e. have holes). Utilizing a spatial divide-and-conquer approach inherent in the quadtree data model, the basic rationale is to narrow-in on portions of each feature quickly that are on a facing edge relative to the other feature, and to minimize the number of point-to-point Euclidean distance calculations that must be performed. Besides offering an efficient, grid-based alternative solution, another unique and useful aspect of the current algorithm is that is can be used for rapidly calculating distance approximations at coarser levels of resolution. The overall process can be viewed as a top-down parallel search. Using one list of leafcode addresses for each of the two features as input, the algorithm is implemented by successively dividing these lists into four sublists for each descendant quadrant. The algorithm consists of two primary phases. The first determines facing adjacent quadrant pairs where part or all of the two features are separated between the two quadrants, respectively. The second phase then determines the closest pixel-level subquadrant pairs within each facing quadrant pair at the lowest level. The key element of the second phase is a quick estimate distance heuristic for further elimination of locations that are not as near as neighboring locations.
Oncoplastic Surgery for Upper/Upper Inner Quadrant Breast Cancer.
Lin, Joseph; Chen, Dar-Ren; Wang, Yu-Fen; Lai, Hung-Wen
2016-01-01
Tumors located in the upper/upper inner quadrant of the breast warrant more attention. A small lesion relative to the size of breast in this location may be resolved by performing a level I oncoplastic technique. However, a wide excision may significantly reduce the overall quality of the breast shape by distorting the visible breast line. From June 2012 to April 2015, 36 patients with breast cancer located in the upper/upper inner quadrant underwent breast-conservation surgery with matrix rotation mammoplasty. According to the size and location of the tumor relative to the nipple-areola complex, 11 patients underwent matrix rotation with periareolar de-epithelialization (donut group) and the other 25 underwent matrix rotation only (non-donut group). The cosmetic results were self-assessed by questionnaires. The average weights of the excised breast lumps in the donut and non-donut groups were 104.1 and 84.5 g, respectively. During the 3-year follow-up period, local recurrence was observed in one case and was managed with nipple-sparing mastectomy followed by breast reconstruction with prosthetic implants. In total, 31 patients (88.6%) ranked their postoperative result as either acceptable or satisfactory. The treated breasts were also self-evaluated by 27 patients (77.1%) to be nearly identical to or just slightly different from the untreated side. Matrix rotation is an easy breast-preserving technique for treating breast cancer located in the upper/upper inner quadrant of the breast that requires a relatively wide excision. With this technique, a larger breast tumor could be removed without compromising the breast appearance.
Prebrushing rinse with water on plaque removal: a split-mouth design.
Van der Sluijs, E; Slot, D E; Hennequin-Hoenderdos, N L; Van Leeuwen, Mpc; Van der Weijden, G A
2017-11-01
The aim was to evaluate whether there is an additional beneficial effect on dental plaque removal of rinsing the oral cavity with water before toothbrushing. In total, 48 non-dental, systemically healthy participants ≥18 years were included in this randomized controlled clinical trial using a split-mouth design. The participants were requested to refrain from any form of oral hygiene for 48 h. First dental plaque scores (PI) were assessed full mouth. Two randomly assigned contra-lateral quadrants were brushed. Next the participant rinsed for 1 min with 15 ml water. Subsequently, the opposite two contra-lateral quadrants were brushed. Brushing was performed without toothpaste. Subsequently the second full-mouth PI assessment was performed. The brushing and rinsing procedure was performed under supervision and brushing time was tracked by a timer, each quadrant was brushed for 30 s. For the buccal, lingual, and approximal surfaces and tooth type, a subanalysis was performed. At baseline there was no statistically significantly difference between the two sets of contra-lateral quadrants. When a water rinse was used before toothbrushing the PI-score was reduced by 58%. If water rinse was used post-brushing the PI-score reduced by 57%. The difference of 0.04 in mean plaque index score reduction between the two brushing regimens was not significant(P = 0.162). When a 2 min brushing exercise was performed, on average more than 55% dental plaque was removed. Prerinsing with water did not contribute significantly to toothbrush efficacy. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Remote Evaluation of Rotational Velocity Using a Quadrant Photo-Detector and a DSC Algorithm
Zeng, Xiangkai; Zhu, Zhixiong; Chen, Yang
2016-01-01
This paper presents an approach to remotely evaluate the rotational velocity of a measured object by using a quadrant photo-detector and a differential subtraction correlation (DSC) algorithm. The rotational velocity of a rotating object is determined by two temporal-delay numbers at the minima of two DSCs that are derived from the four output signals of the quadrant photo-detector, and the sign of the calculated rotational velocity directly represents the rotational direction. The DSC algorithm does not require any multiplication operations. Experimental calculations were performed to confirm the proposed evaluation method. The calculated rotational velocity, including its amplitude and direction, showed good agreement with the given one, which had an amplitude error of ~0.3%, and had over 1100 times the efficiency of the traditional cross-correlation method in the case of data number N > 4800. The confirmations have shown that the remote evaluation of rotational velocity can be done without any circular division disk, and that it has much fewer error sources, making it simple, accurate and effective for remotely evaluating rotational velocity. PMID:27120607
Clinical presentation and manual therapy for lower quadrant musculoskeletal conditions.
Courtney, Carol A; Clark, Jeffrey D; Duncombe, Alison M; O'Hearn, Michael A
2011-11-01
Chronic lower quadrant injuries constitute a significant percentage of the musculoskeletal cases seen by clinicians. While impairments may vary, pain is often the factor that compels the patient to seek medical attention. Traumatic injury from sport is one cause of progressive chronic joint pain, particularly in the lower quarter. Recent studies have demonstrated the presence of peripheral and central sensitization mechanisms in different lower quadrant pain syndromes, such as lumbar spine related leg pain, osteoarthritis of the knee, and following acute injuries such as lateral ankle sprain and anterior cruciate ligament rupture. Proper management of lower quarter conditions should include assessment of balance and gait as increasing pain and chronicity may lead to altered gait patterns and falls. In addition, quantitative sensory testing may provide insight into pain mechanisms which affect management and prognosis of musculoskeletal conditions. Studies have demonstrated analgesic effects and modulation of spinal excitability with use of manual therapy techniques, with clinical outcomes of improved gait and functional ability. This paper will discuss the evidence which supports the use of manual therapy for lower quarter musculoskeletal dysfunction.
Path attenuation statistics influenced by orientation of rain cells
NASA Technical Reports Server (NTRS)
Goldhirsh, J.
1976-01-01
The influence of path azimuth on fade and space diversity statistics associated with propagation along earth-satellite paths at a frequency of 18 GHz is examined. A radar rain reflectivity data base obtained during the summer of 1973 is injected into a modeling program and the attenuation along parallel earth-satellite paths are obtained for a conglomeration of azimuths. Statistics are separated into two groupings: one pertaining to earth-satellite paths oriented in the northwest-southeast and the other in the northeast-southwest quadrants using a fixed elevation angle of 45 deg. The latter case shows fading to be greater with a degraded space diversity suggesting rain cells to be elongated along this direction. Cell dimensions are analyzed for both sets of quadrants and are found to have average values larger by 2 km in the northeast-southwest quadrants; a result consistent with the fade and space diversity results. Examination of the wind direction for the 14 rain days of data analyzed shows good correlation of the average or median wind directions with the directions of maximum fading and degraded space diversity.
Task specificity of attention training: the case of probability cuing
Jiang, Yuhong V.; Swallow, Khena M.; Won, Bo-Yeong; Cistera, Julia D.; Rosenbaum, Gail M.
2014-01-01
Statistical regularities in our environment enhance perception and modulate the allocation of spatial attention. Surprisingly little is known about how learning-induced changes in spatial attention transfer across tasks. In this study, we investigated whether a spatial attentional bias learned in one task transfers to another. Most of the experiments began with a training phase in which a search target was more likely to be located in one quadrant of the screen than in the other quadrants. An attentional bias toward the high-probability quadrant developed during training (probability cuing). In a subsequent, testing phase, the target's location distribution became random. In addition, the training and testing phases were based on different tasks. Probability cuing did not transfer between visual search and a foraging-like task. However, it did transfer between various types of visual search tasks that differed in stimuli and difficulty. These data suggest that different visual search tasks share a common and transferrable learned attentional bias. However, this bias is not shared by high-level, decision-making tasks such as foraging. PMID:25113853
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xin, G. G.; Ye, D. F.; Graduate School, China Academy of Engineering Physics, Beijing 100088
2010-12-15
In the present paper, we investigate the correlated electron emission of atoms irradiated by a few-cycle laser pulse, with emphasis on the correlated longitudinal momentum spectra. We find that the spectra show clear v-shaped structures, in analogy to what was observed recently in long-pulse experiments. Moreover, the patterns of the spectra depend sensitively on the carrier-envelope phase as well as the laser intensity. The v-shaped structure is more pronounced at lower and higher intensities and becomes obscure at medium intensity. At a lower intensity, upon change of the phase from 0 to {pi}/2, the v-shaped structure shifts from the firstmore » quadrant to the third quadrant and the ratios between the double ionization yields in the first and third quadrants are found to increase by a few orders of magnitude. The semiclassical rescattering model is exploited in the preceding calculations and the underlying mechanisms are uncovered by analyzing the subcycle dynamics of classical trajectories.« less
Advanced Technology Composite Fuselage: Program Overview
NASA Technical Reports Server (NTRS)
Ilcewicz, L. B.; Smith, P. J.; Hanson, C. T.; Walker, T. H.; Metschan, S. L.; Mabson, G. E.; Wilden, K. S.; Flynn, B. W.; Scholz, D. B.; Polland, D. R.;
1997-01-01
The Advanced Technology Composite Aircraft Structures (ATCAS) program has studied transport fuselage structure with a large potential reduction in the total direct operating costs for wide-body commercial transports. The baseline fuselage section was divided into four 'quadrants', crown, keel, and sides, gaining the manufacturing cost advantage possible with larger panels. Key processes found to have savings potential include (1) skins laminated by automatic fiber placement, (2) braided frames using resin transfer molding, and (3) panel bond technology that minimized mechanical fastening. The cost and weight of the baseline fuselage barrel was updated to complete Phase B of the program. An assessment of the former, which included labor, material, and tooling costs, was performed with the help of design cost models. Crown, keel, and side quadrant cost distributions illustrate the importance of panel design configuration, area, and other structural details. Composite sandwich panel designs were found to have the greatest cost savings potential for most quadrants. Key technical findings are summarized as an introduction to the other contractor reports documenting Phase A and B work completed in functional areas. The current program status in resolving critical technical issues is also highlighted.
Multi-Hop Link Capacity of Multi-Route Multi-Hop MRC Diversity for a Virtual Cellular Network
NASA Astrophysics Data System (ADS)
Daou, Imane; Kudoh, Eisuke; Adachi, Fumiyuki
In virtual cellular network (VCN), proposed for high-speed mobile communications, the signal transmitted from a mobile terminal is received by some wireless ports distributed in each virtual cell and relayed to the central port that acts as a gateway to the core network. In this paper, we apply the multi-route MHMRC diversity in order to decrease the transmit power and increase the multi-hop link capacity. The transmit power, the interference power and the link capacity are evaluated for DS-CDMA multi-hop VCN by computer simulation. The multi-route MHMRC diversity can be applied to not only DS-CDMA but also other access schemes (i. e. MC-CDMA, OFDM, etc.).
Mihara, Naoki; Ueda, Kanayo; Manabe, Shirou; Takeda, Toshihiro; Shimai, Yoshie; Horishima, Hiroyuki; Murata, Taizo; Fujii, Ayumi; Matsumura, Yasushi
2015-01-01
Recently one patient received care from several hospitals at around the same time. When the patient visited a new hospital, the new hospital's physician tried to get patient information the previous hospital. Thus, patient information is frequently exchanged between them. Many types of healthcare facilities have implemented an electronic medical record system, but in Japan, healthcare information exchange is often done by paper. In other words, after a clinical doctor prints a referral document and sends it to another hospital's physician, another hospital's doctor receives it and scans to store the EMR in his own hospital's system. It is a wasteful way to exchange healthcare information about a patient. In order to solve this problem, we have developed a cross-institutional document exchange system using clinical document architecture (CDA) with a virtual printing method.
Analgesic effects of posthypnotic suggestions and virtual reality distraction on thermal pain.
Patterson, D R; Hoffman, H G; Palacios, A Garcia; Jensen, M J
2006-11-01
The individual and combined effects of posthypnotic suggestion (PHS) and virtual reality distraction (VRD) on experimentally induced thermal pain were examined using a 2 x 2, between-groups design. After receiving baseline thermal pain, each participant received hypnosis or no hypnosis, followed by VRD or no VRD during another pain stimulus. Consistent with the hypothesis that hypnosis and VRD work via different mechanisms, results show that posthypnotic analgesia was moderated by hypnotizability but VRD analgesia was not. The impact of PHSs for analgesia was specific to high hypnotizables, whereas VRD was effective independent of hypnotizability. Results also show a nonsignificant but predicted pattern for high hypnotizables: Audio hypnosis combined with VRD reduced worst pain 22% more and pain unpleasantness 25% more than did VRD alone. Theoretical and clinical implications are discussed. (c) 2006 APA, all rights reserved.
Lee, Kyoung-Hee
2015-01-01
This study aimed to determine the effects of a virtual reality exercise program using the Interactive Rehabilitation and Exercise System (IREX) on the recovery of motor and cognitive function and the performance of activities of daily living in stroke patients. [Subjects] The study enrolled 10 patients diagnosed with stroke who received occupational therapy at the Department of Rehabilitation Medicine of Hospital A between January and March 2014. [Methods] The patients took part in the virtual reality exercise program for 30 minutes each day, three times per week, for 4 weeks. Then, the patients were re-evaluated to determine changes in upper extremity function, cognitive function, and performance of activities of daily living 4 weeks after the baseline assessment. [Results] In the experimental group, there were significant differences in the Korea-Mini Mental Status Evaluation, Korean version of the modified Barthel index, and Fugl-Meyer assessment scores between the baseline and endpoint. [Conclusion] The virtual reality exercise program was effective for restoring function in stroke patients. Further studies should develop systematic protocols for rehabilitation training with a virtual reality exercise program. PMID:26180287
Lee, Kyoung-Hee
2015-06-01
This study aimed to determine the effects of a virtual reality exercise program using the Interactive Rehabilitation and Exercise System (IREX) on the recovery of motor and cognitive function and the performance of activities of daily living in stroke patients. [Subjects] The study enrolled 10 patients diagnosed with stroke who received occupational therapy at the Department of Rehabilitation Medicine of Hospital A between January and March 2014. [Methods] The patients took part in the virtual reality exercise program for 30 minutes each day, three times per week, for 4 weeks. Then, the patients were re-evaluated to determine changes in upper extremity function, cognitive function, and performance of activities of daily living 4 weeks after the baseline assessment. [Results] In the experimental group, there were significant differences in the Korea-Mini Mental Status Evaluation, Korean version of the modified Barthel index, and Fugl-Meyer assessment scores between the baseline and endpoint. [Conclusion] The virtual reality exercise program was effective for restoring function in stroke patients. Further studies should develop systematic protocols for rehabilitation training with a virtual reality exercise program.
Muñoz, Karen; Kibbe, Kristin; Preston, Elizabeth; Caballero, Ana; Nelson, Lauri; White, Karl; Twohig, Michael
2017-02-01
The purpose of this study was to explore the use of virtual visits to monitor hearing aid use with data logging measurements and provide parent support for hearing aid management. A 6-month longitudinal case study design was used. Four families and two providers participated. Average hours of daily hearing aid use increased 3.5 h from the beginning to the end of the study period. Prior to receiving virtual visits, the parents and the clinicians generally indicated they were hopeful about the benefits of virtual visits including the frequency and convenience of the appointments but had some concerns about technical difficulties. These concerns diminished at the conclusion of the study. Virtual visits provided benefits to families including flexibility and timely access to support. The ability to collect data logging information more frequently was important for effective problem-solving to increase hearing aid use. Both parents and clinicians were accepting of tele-support. Parents and professionals would benefit from technology that allows them to access data logging information more easily and frequently.
JahaniShoorab, Nahid; Ebrahimzadeh Zagami, Samira; Nahvi, Ali; Mazluom, Seyed Reza; Golmakani, Nahid; Talebi, Mahdi; Pabarja, Ferial
2015-01-01
Background Pain is one of the side effects of episiotomy. The virtual reality (VR) is a non-pharmacological method for pain relief. The purpose of this study was to determine the effect of using video glasses on pain reduction in primiparity women during episiotomy repair. Methods This clinical trial was conducted on 30 primiparous parturient women having labor at Omolbanin Hospital (Mashhad, Iran) during May-July 2012. Samples during episiotomy repair were randomly divided into two equal groups. The intervention group received the usual treatment with VR (video glasses and local infiltration 5 ml solution of lidocaine 2%) and the control group only received local infiltration (5 ml solution of lidocaine 2%). Pain was measured using the Numeric Pain Rating Scale (0-100 scale) before, during and after the episiotomy repair. Data were analyzed using Fisher’s exact test, Chi-square, Mann-Whitney and repeated measures ANOVA tests by SPSS 11.5 software. Results There were statistically significant differences between the pain score during episiotomy repair in both groups (P=0.038). Conclusion Virtual reality is an effective complementary non-pharmacological method to reduce pain during episiotomy repair. Trial Registration Number: IRCT138811063185N1. PMID:25999621
Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T
2018-04-17
Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.
Faber, Albertus W.; Patterson, David R.; Bremer, Marco
2012-01-01
Objective The current study explored whether immersive virtual reality continues to reduce pain (via distraction) during more than one wound care session per patient. Patients: Thirty six patients aged 8 to 57 years (mean age of 27.7 years), with an average of 8.4% total body surface area burned (range .25 to 25.5 TBSA) received bandage changes, and wound cleaning. Methods Each patient received one baseline wound cleaning/debridement session with no-VR (control condition) followed by one or more (up to seven) subsequent wound care sessions during VR. After each wound care session (one session per day), worst pain intensity was measured using a Visual Analogue Thermometer (VAT), the dependent variable. Using a within subjects design, worst pain intensity VAT during wound care with no-VR (baseline, Day 0) was compared to pain during wound care while using immersive virtual reality (up to seven days of wound care during VR). Results Compared to pain during no-VR Baseline (Day 0), pain ratings during wound debridement were statistically lower when patients were in virtual reality on Days 1, 2 and 3, and although not significant beyond day 3, the pattern of results from Days 4, 5, and 6 are consistent with the notion that VR continues to reduce pain when used repeatedly. Conclusions Results from the present study suggest that VR continues to be effective when used for three (or possibly more) treatments during severe burn wound debridement. PMID:23970314
Virtual reality intervention for older women with breast cancer.
Schneider, Susan M; Ellis, Mathew; Coombs, William T; Shonkwiler, Erin L; Folsom, Linda C
2003-06-01
This study examined the effects of a virtual reality distraction intervention on chemotherapy-related symptom distress levels in 16 women aged 50 and older. A cross-over design was used to answer the following research questions: (1) Is virtual reality an effective distraction intervention for reducing chemotherapy-related symptom distress levels in older women with breast cancer? (2) Does virtual reality have a lasting effect? Chemotherapy treatments are intensive and difficult to endure. One way to cope with chemotherapy-related symptom distress is through the use of distraction. For this study, a head-mounted display (Sony PC Glasstron PLM - S700) was used to display encompassing images and block competing stimuli during chemotherapy infusions. The Symptom Distress Scale (SDS), Revised Piper Fatigue Scale (PFS), and the State Anxiety Inventory (SAI) were used to measure symptom distress. For two matched chemotherapy treatments, one pre-test and two post-test measures were employed. Participants were randomly assigned to receive the VR distraction intervention during one chemotherapy treatment and received no distraction intervention (control condition) during an alternate chemotherapy treatment. Analysis using paired t-tests demonstrated a significant decrease in the SAI (p = 0.10) scores immediately following chemotherapy treatments when participants used VR. No significant changes were found in SDS or PFS values. There was a consistent trend toward improved symptoms on all measures 48 h following completion of chemotherapy. Evaluation of the intervention indicated that women thought the head mounted device was easy to use, they experienced no cybersickness, and 100% would use VR again.
Virtual rehabilitation in a school setting: is it feasible for children with cerebral palsy?
Rosie, Juliet A; Ruhen, Shelley; Hing, Wayne A; Lewis, Gwyn N
2015-01-01
To determine the feasibility of a school-based virtual rehabilitation intervention for children with cerebral palsy. A feasibility study was conducted using a mixed method approach. Participants were five children with cerebral palsy who were currently attending a rural school. Each child received an 8-week rehabilitation programme involving an Interactive Virtual Reality Exercise (IREX) system. The IREX was placed in the child's school for the duration of the intervention. Each child's programme was designed by a physiotherapist but supervised by a teacher aide at the school. Feasibility of the intervention was assessed through a questionnaire completed by the child and an interview conducted with the teacher supervisor. The children all rated the IREX intervention as fun, easy to use, and beneficial for their arm. Categories from the supervisor interviews centred on resolving technical issues, the enjoyment of taking part due to the child's progress, and the central role of interacting with the child. Input from the research physiotherapist was critical to the success of the intervention. The IREX is feasible to implement in a school-based setting supervised by teachers. This provides an option for delivering physiotherapy to children in isolated areas who do not receive on-going therapy. Implication for Rehabilitation Virtual rehabilitation programmes using the IREX are feasible in a school-based setting. The negative impact of technical difficulties is likely to be overcome by the user's enjoyment and rehabilitation benefits gained. Input from a therapist in designing and monitoring the programme is critical.
An Analysis of Decision Making in a Military Population
1985-03-01
1 2 ENFP 1 2 INFJ 0 0 ENFJ 0 0 INTP 2 5 ENTP 3 7 INTJ 0 0 ENTJ 2 5 ESTJ 6 14 ISTJ 22 51 ESTP 1 2 ISTP 2 5 ESFJ 0 0 ISFJ 3 7 ESFP 0 0 ISFP 0 0 B-1I...3-25 3-5 Quadrant Theory Variables . . . . . . . . . . . . . . 3-31 3-6 Predicted Relationships Between Pairs Of Instruments 3-32 3-7 22 x 22...And The HPSF Quadrant Variables Only . . . . . . . . . . . . . . . . . . . 3-43 3-17 Summary Of Relationships For Each Pair Of Instruments 3-45 3-18
NASA Astrophysics Data System (ADS)
Nelson, H. Roice
1997-06-01
A virtual seminar (SM) is an economic and effective instructional tool for teaching students who are at a distance from their instructor. Like conventional class room teaching, a virtual seminar requires an instructor, a student, and a method of communication. Teleconferencing, video conferencing, intranets and the Internet give learners in a Virtual Seminar the ability to interact immediately with their mentors and receive real and relevant answers. This paper shows how industry and academia can benefit from using methods developed and experience gained in presenting the first virtual seminars to academic and petroleum industry participants in mid-1996. The information explosion in industry means that business or technical information is worthless until it is assimilated into a corporate knowledge management system. A search for specific information often turns into a filtering exercise or an attempt to find patterns and classify retrieved material. In the setting of an interactive corporate information system, virtual seminars meet the need for a productive new relationship between creative people and the flux of corporate knowledge. Experience shows that it is more efficient to circulate timesensitive and confidential information electronically through a virtual seminar. Automating the classification of information and removing that task from the usual work load creates an electronic corporate memory and enhances the value of the knowledge to both users and a corporation. Catalogued benchmarks, best-practice standards, and Knowledge Maps (SM) of experience serve as key aids to communicating knowledge through virtual seminars and converting that knowledge into a profit-making asset.
Witmer, Matthew T; Parlitsis, George; Patel, Sarju; Kiss, Szilárd
2013-01-01
Purpose To compare ultra-widefield fluorescein angiography imaging using the Optos® Optomap® and the Heidelberg Spectralis® noncontact ultra-widefield module. Methods Five patients (ten eyes) underwent ultra-widefield fluorescein angiography using the Optos® panoramic P200Tx imaging system and the noncontact ultra-widefield module in the Heidelberg Spectralis® HRA+OCT system. The images were obtained as a single, nonsteered shot centered on the macula. The area of imaged retina was outlined and quantified using Adobe® Photoshop® C5 software. The total area and area within each of four visualized quadrants was calculated and compared between the two imaging modalities. Three masked reviewers also evaluated each quadrant per eye (40 total quadrants) to determine which modality imaged the retinal vasculature most peripherally. Results Optos® imaging captured a total retinal area averaging 151,362 pixels, ranging from 116,998 to 205,833 pixels, while the area captured using the Heidelberg Spectralis® was 101,786 pixels, ranging from 73,424 to 116,319 (P = 0.0002). The average area per individual quadrant imaged by Optos® versus the Heidelberg Spectralis® superiorly was 32,373 vs 32,789 pixels, respectively (P = 0.91), inferiorly was 24,665 vs 26,117 pixels, respectively (P = 0.71), temporally was 47,948 vs 20,645 pixels, respectively (P = 0.0001), and nasally was 46,374 vs 22,234 pixels, respectively (P = 0.0001). The Heidelberg Spectralis® was able to image the superior and inferior retinal vasculature to a more distal point than was the Optos®, in nine of ten eyes (18 of 20 quadrants). The Optos® was able to image the nasal and temporal retinal vasculature to a more distal point than was the Heidelberg Spectralis®, in ten of ten eyes (20 of 20 quadrants). Conclusion The ultra-widefield fluorescein angiography obtained with the Optos® and Heidelberg Spectralis® ultra-widefield imaging systems are both excellent modalities that provide views of the peripheral retina. On a single nonsteered image, the Optos® Optomap® covered a significantly larger total retinal surface area, with greater image variability, than did the Heidelberg Spectralis® ultra-widefield module. The Optos® captured an appreciably wider view of the retina temporally and nasally, albeit with peripheral distortion, while the ultra-widefield Heidelberg Spectralis® module was able to image the superior and inferior retinal vasculature more peripherally. The clinical significance of these findings as well as the area imaged on steered montaged images remains to be determined. PMID:23458976
ERIC Educational Resources Information Center
Sacks, Joann Y.; Sacks, Stanley; Mckendrick, Karen; Banks, Steven; Schoeneberger, Marlies; Hamilton, Zachary; Stommel, Joseph; Shoemaker, Joanie
2008-01-01
This random assignment study compared women in a prison Therapeutic Community (TC) program with those in a cognitive-behavioral intervention. Over two thirds of study subjects received a lifetime diagnosis of severe mental disorder, nearly one-half received a diagnosis of PTSD, and virtually all reported exposure to trauma. Preliminary analysis (n…
Yuvacı, İsa; Pangal, Emine; Bayram, Nurettin; Yüksel, Sevgi Arık; Alabay, Bedirhan; Ağadayı, Alperen; Sırakaya, Ender; Gülhan, Ahmet
2016-01-01
Evaluation of the nerve fiber thicknesses of the macula, choroid, and retina using the apnea-hypopnea index in individuals with obstructive sleep apnea syndrome (OSAS) without systemic components. Prospective, controlled study. The central macular, choroidal, and retinal nerve fiber layer (RNFL) thicknesses were evaluated using enhanced depth imaging-spectral domain optical coherence tomography in individuals with OSAS. In people with severe OSAS who had received treatment, posterior ocular structures were examined over 3 months (4th and 12th weeks), and changes were evaluated. Only the right eyes of the participants were evaluated in the study. A total of 72 people were involved in the study, with 18 in the control group and 19 with mild, 16 with moderate, and 19 with severe OSAS. No significant difference was found among the groups in terms of demographic measures. No significant differences were found among the groups in terms of the measures of central macular, central subfoveal choroidal (CSCT), temporal choroidal, nasal choroidal, and RNFL thicknesses. In severe OSAS cases in which treatment was administered, although subjective clinical recovery was observed, statistically significant thinning was detected during the 3-month follow-up period in the CSCT, general RNFL, as well as in the inferior and superior nasal quadrants, and temporal superior quadrant (p=0.005, p=0.009, p=0.039, p=0.003, and p=0.02, respectively). In the group with severe OSAS, thinning in some posterior ocular tissues was observed. Although patients with severe OSAS may experience clinical recovery, we recommend that they would be followed up in terms of ocular ischemic injury.
Tsikata, Edem; Lee, Ramon; Shieh, Eric; Simavli, Huseyin; Que, Christian J.; Guo, Rong; Khoueir, Ziad; de Boer, Johannes; Chen, Teresa C.
2016-01-01
Purpose To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-μm reference surface–based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. Results The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-μm reference surface had diagnostic capabilities similar to RNFL thickness. Conclusions The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors. PMID:27768203
Khoueir, Ziad; Jassim, Firas; Poon, Linda Yi-Chieh; Tsikata, Edem; Ben-David, Geulah S; Liu, Yingna; Shieh, Eric; Lee, Ramon; Guo, Rong; Papadogeorgou, Georgia; Braaf, Boy; Simavli, Huseyin; Que, Christian; Vakoc, Benjamin J; Bouma, Brett E; de Boer, Johannes F; Chen, Teresa C
2017-10-01
To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). Assessment of diagnostic accuracy. Setting: Academic clinical setting. Total of 180 patients (113 OAG and 67 normal subjects). One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm 2 scanned region. Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant. Copyright © 2017 Elsevier Inc. All rights reserved.
Mohammadpour, Toktam; Hosseini, Mahmoud; Naderi, Asieh; Karami, Reza; Sadeghnia, Hamid Reza; Soukhtanloo, Mohammad; Vafaee, Farzaneh
2015-10-01
Hypnotic, analgesic, anticonvulsant, and antioxidant effects of Rosa damascena have been reported. This study, investigated the effect of R. damascena hydroalcoholic extract on memory performance in a scopolamine-induced memory impairment model. The rats were divided into control group received just saline; scopolamine group was treated by saline for 2 weeks, but was injected by scopolamine 30 minutes before each trial in Morris water maze test; treatment groups (scopolamine + extract 50; Sco + Ext 50) and (scopolamine + extract 250; Sco + Ext 250) were daily treated by 50 and 250 mg/kg of R. damascena extract (2 weeks) and were finally injected by scopolamine before each trial in Morris water maze. The brains were removed for biochemical measurements. Time latency and path length in the scopolamine group were higher than control (P < 0.01 to <0.001). Both treatment groups showed shorter traveled distance and time latency compared with scopolamine group (P < 0.05 to <0.001). Time spent in target quadrant by scopolamine group was lower than control (P < 0.05), while Sco + Ext 250 group spent longer time in target quadrant than scopolamine group (P < 0.05). Malondialdehyde concentrations in hippocampal and cortical tissues of scopolamine group were higher, while thiol concentrations were lower than control ones (P < 0.001). Treatment by both doses of the extract decreased the malondialdehyde concentration, while increased the thiol concentration (P < 0.05 to <0.001). The results of this study showed that the hydroalcoholic extract of R. damascena prevents scopolamine-induced memory deficits. This finding suggests that memory improvement may be in part due to the antioxidant effects.
Martins, Fabiana; Simões, Alyne; Oliveira, Marcio; Luiz, Ana Claudia; Gallottini, Marina; Pannuti, Claudio
2016-12-01
Down syndrome (DS) has characteristics that include mental retardation, a characteristic phenotype, congenital heart defects, immune disorders, and increased risk of periodontal disease (PD). Antimicrobial photodynamic therapy (aPDT) is the combined use of photosensitizers associated with low-level laser (LLL) and oxygen, leading to singlet oxygen formation, which contributes to the antibacterial activity of the phagocytes, killing bacteria. The objective of this study was to evaluate the efficacy of aPDT as an adjuvant to conventional periodontal treatment of PD in DS patients. A double-blinded, controlled, randomized, split-mouth study was conducted. A total of 13 DS subjects who were 18 years or older and who presented at least one tooth in each quadrant of the mouth with probing pocket depth (PPD) equal to or greater than 5 mm were included. The patients were evaluated at three different times: at the baseline, PPD were obtained. After 1 week, conventional scaling and root planing (SRP) was performed, and two randomly selected quadrants also received aPDT. One month after SRP, all the patients were reevaluated. Periodontal conditions were improved among all the participants. The PDT-with-SRP group presented a nonsignificant reduction in PPD (mean = 1.27 mm, median = 1.17 mm) relative to that of the SRP group (mean = 1.00 mm, median = 0.95 mm). Changes over time were compared using the Wilcoxon test. A significant reduction in median PPD was observed in both groups (p = 0.001). Both types of periodontal treatment, with and without PDT, were similarly effective and were associated with good clinical response.
Smokeless Tobacco Use and Periodontal Health in a Rural Male Population
Chu, Yong H.; Tatakis, Dimitris N.
2010-01-01
Background Despite the reported effects of smokeless tobacco (ST) on the periodontium and high prevalence of ST use in rural populations and in men, studies on this specific topic are limited. The purpose of this cross-sectional investigation is to evaluate the periodontal health status of male ST users from a rural population. Methods Adult male residents of two rural Appalachian Ohio counties and daily ST users, with a unilateral mandibular oral ST keratosis lesion, were recruited. Subjects completed a questionnaire and received oral examination. Teeth present, ST keratosis lesion, plaque and gingival index, probing depth (PD), recession depth (RD), and attachment level were recorded. Statistical analysis compared ST-site mandibular teeth (teeth adjacent to the subject’s unilateral ST keratosis lesion) to NST-site teeth (contralateral corresponding teeth). Results This study includes 73 ST users. Recession prevalence is much greater in ST-site quadrants (36%) compared to NST-site quadrants (18%; P <0.001). Twice as many teeth had recession on ST-site (approximately 20%) than NST-site (approximately 10%; P = 0.0001). Average buccal RD on ST-site teeth did not differ from that on the NST-site teeth (P = 0.0875). Although average buccal attachment loss is greater on ST-site teeth (P = 0.016), the mean difference is <0.5 mm. When stratified by years of ST use, subjects using ST for 10 to 18 years exhibit the most differences between ST and NST sites, whereas subjects using ST for <10 years show no differences. Conclusion The results indicate that greater gingival recession prevalence and extent are associated with ST placement site in rural male ST users. PMID:20350155
Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.
Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A
2012-12-01
To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Automated analysis of angle closure from anterior chamber angle images.
Baskaran, Mani; Cheng, Jun; Perera, Shamira A; Tun, Tin A; Liu, Jiang; Aung, Tin
2014-10-21
To evaluate a novel software capable of automatically grading angle closure on EyeCam angle images in comparison with manual grading of images, with gonioscopy as the reference standard. In this hospital-based, prospective study, subjects underwent gonioscopy by a single observer, and EyeCam imaging by a different operator. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. An eye was classified as having angle closure if there were two or more quadrants of closure. Automated grading of the angle images was performed using customized software. Agreement between the methods was ascertained by κ statistic and comparison of area under receiver operating characteristic curves (AUC). One hundred forty subjects (140 eyes) were included, most of whom were Chinese (102/140, 72.9%) and women (72/140, 51.5%). Angle closure was detected in 61 eyes (43.6%) with gonioscopy in comparison with 59 eyes (42.1%, P = 0.73) using manual grading, and 67 eyes (47.9%, P = 0.24) with automated grading of EyeCam images. The agreement for angle closure diagnosis between gonioscopy and both manual (κ = 0.88; 95% confidence interval [CI), 0.81-0.96) and automated grading of EyeCam images was good (κ = 0.74; 95% CI, 0.63-0.85). The AUC for detecting eyes with gonioscopic angle closure was comparable for manual and automated grading (AUC 0.974 vs. 0.954, P = 0.31) of EyeCam images. Customized software for automated grading of EyeCam angle images was found to have good agreement with gonioscopy. Human observation of the EyeCam images may still be needed to avoid gross misclassification, especially in eyes with extensive angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Park, Chan-Bin; Choi, Jung-Seok; Park, Su Mi; Lee, Jun-Young; Jung, Hee Yeon; Seol, Jin-Mi; Hwang, Jae Yeon; Gwak, Ah Reum; Kwon, Jun Soo
2014-04-01
Previous studies have reported promising results regarding the effect of repeated virtual cue exposure therapy on nicotine dependence. This study aimed to compare the effectiveness of virtual cue exposure therapy (CET) and cognitive behavioral therapy (CBT) for nicotine dependence. Thirty subjects with nicotine dependence participated in 4 weeks of treatment with either virtual CET (n=15) or CBT (n=15). All patients were male, and none received nicotine replacement treatment during the study period. The main setting of the CET used in this study was a virtual bar. The primary foci of the CBT offered were (a) smoking cessation education, (b) withdrawal symptoms, (c) coping with high-risk situations, (d) cognitive reconstruction, and (e) stress management. Daily smoking count, level of expiratory carbon monoxide (CO), level of nicotine dependence, withdrawal symptoms, and subjective craving were examined on three occasions: week 0 (baseline), week 4 (end of treatment), and week 12 (follow-up assessment). After treatment, the daily smoking count, the expiratory CO, and nicotine dependence levels had significantly decreased. These effects continued during the entire study period. Similar changes were observed in both virtual CET and CBT groups. We found no interaction between type of therapy and time of measurement. Although the current findings are preliminary, the present study provided evidence that virtual CET is effective for the treatment of nicotine dependence at a level comparable to CBT.
Qu, Chao; Ling, Yun; Heynderickx, Ingrid; Brinkman, Willem-Paul
2015-01-01
Bystanders in a real world's social setting have the ability to influence people’s beliefs and behavior. This study examines whether this effect can be recreated in a virtual environment, by exposing people to virtual bystanders in a classroom setting. Participants (n = 26) first witnessed virtual students answering questions from an English teacher, after which they were also asked to answer questions from the teacher as part of a simulated training for spoken English. During the experiment the attitudes of the other virtual students in the classroom was manipulated; they could whisper either positive or negative remarks to each other when a virtual student was talking or when a participant was talking. The results show that the expressed attitude of virtual bystanders towards the participants affected their self-efficacy, and their avoidance behavior. Furthermore, the experience of witnessing bystanders commenting negatively on the performance of other students raised the participants’ heart rate when it was their turn to speak. Two-way interaction effects were also found on self-reported anxiety and self-efficacy. After witnessing bystanders’ positive attitude towards peer students, participants’ self-efficacy when answering questions received a boost when bystanders were also positive towards them, and a blow when bystanders reversed their attitude by being negative towards them. Still, inconsistency, instead of consistency, between the bystanders’ attitudes towards virtual peers and the participants was not found to result in a larger change in the participants’ beliefs. Finally the results also reveal that virtual flattering or destructive criticizing affected the participants’ beliefs not only about the virtual bystanders, but also about the neutral teacher. Together these findings show that virtual bystanders in a classroom can affect people’s beliefs, anxiety and behavior. PMID:25884211
2013-01-01
Background Psychological stress occurs when an individual perceives that environmental demands tax or exceed his or her adaptive capacity. Its association with severe health and emotional diseases, points out the necessity to find new efficient strategies to treat it. Moreover, psychological stress is a very personal problem and requires training focused on the specific needs of individuals. To overcome the above limitations, the INTERSTRESS project suggests the adoption of a new paradigm for e-health - Interreality - that integrates contextualized assessment and treatment within a hybrid environment, bridging the physical and the virtual worlds. According to this premise, the aim of this study is to investigate the advantages of using advanced technologies, in combination with cognitive behavioral therapy (CBT), based on a protocol for reducing psychological stress. Methods/Design The study is designed as a randomized controlled trial. It includes three groups of approximately 50 subjects each who suffer from psychological stress: (1) the experimental group, (2) the control group, (3) the waiting list group. Participants included in the experimental group will receive a treatment based on cognitive behavioral techniques combined with virtual reality, biofeedback and mobile phone, while the control group will receive traditional stress management CBT-based training, without the use of new technologies. The wait-list group will be reassessed and compared with the two other groups five weeks after the initial evaluation. After the reassessment, the wait-list patients will randomly receive one of the two other treatments. Psychometric and physiological outcomes will serve as quantitative dependent variables, while subjective reports of participants will be used as the qualitative dependent variable. Discussion What we would like to show with the present trial is that bridging virtual experiences, used to learn coping skills and emotional regulation, with real experiences using advanced technologies (virtual reality, advanced sensors and smartphones) is a feasible way to address actual limitations of existing protocols for psychological stress. Trial registration http://clinicaltrials.gov/ct2/show/NCT01683617 PMID:23806013
NASA Technical Reports Server (NTRS)
Pogorzelski, R. J.; Beckon, R. J.
1997-01-01
The virtual spacecraft concept is embodied in a set of subsystems, either in the form of hardware or computational models, which together represent all, or a portion of, a spacecraft. For example, the telecommunications transponder may be a hardware prototype while the propulsion system may exist only as a simulation. As the various subsystems are realized in hardware, the spacecraft becomes progressively less virtual. This concept is enabled by JPL's Mission System Testbed which is a set of networked workstations running a message passing operating system called "TRAMEL" which stands for Task Remote Asynchronous Message Exchange Layer. Each simulation on the workstations, which may in fact be hardware controlled by the workstation, "publishes" its operating parameters on TRAMEL and other simulations requiring those parameters as input may "subscribe" to them. In this manner, the whole simulation operates as a single virtual system. This paper describes a simulation designed to evaluate a communications link between the earth and the Mars Pathfinder Lander module as it descends under a parachute through the Martian atmosphere toward the planet's surface. This link includes a transmitter and a low gain antenna on the spacecraft and a receiving antenna and receiver on the earth as well as a simulation of the dynamics of the spacecraft. The transmitter, the ground station antenna, the receiver and the dynamics are all simulated computationally while the spacecraft antenna is implemented in hardware on a very simple spacecraft mockup. The dynamics simulation is a record of one output of the ensemble of outputs of a Monte Carlo simulation of the descent. Additionally, the antenna/spacecraft mock-up system was simulated using APATCH, a shooting and bouncing ray code developed by Demaco, Inc. The antenna simulation, the antenna hardware, and the link simulation are all physically located in different facilities at JPL separated by several hundred meters and are linked via the local area network (LAN).
Shokur, Solaiman; Gallo, Simone; Moioli, Renan C; Donati, Ana Rita C; Morya, Edgard; Bleuler, Hannes; Nicolelis, Miguel A L
2016-09-19
Spinal cord injuries disrupt bidirectional communication between the patient's brain and body. Here, we demonstrate a new approach for reproducing lower limb somatosensory feedback in paraplegics by remapping missing leg/foot tactile sensations onto the skin of patients' forearms. A portable haptic display was tested in eight patients in a setup where the lower limbs were simulated using immersive virtual reality (VR). For six out of eight patients, the haptic display induced the realistic illusion of walking on three different types of floor surfaces: beach sand, a paved street or grass. Additionally, patients experienced the movements of the virtual legs during the swing phase or the sensation of the foot rolling on the floor while walking. Relying solely on this tactile feedback, patients reported the position of the avatar leg during virtual walking. Crossmodal interference between vision of the virtual legs and tactile feedback revealed that patients assimilated the virtual lower limbs as if they were their own legs. We propose that the addition of tactile feedback to neuroprosthetic devices is essential to restore a full lower limb perceptual experience in spinal cord injury (SCI) patients, and will ultimately, lead to a higher rate of prosthetic acceptance/use and a better level of motor proficiency.
Shokur, Solaiman; Gallo, Simone; Moioli, Renan C.; Donati, Ana Rita C.; Morya, Edgard; Bleuler, Hannes; Nicolelis, Miguel A.L.
2016-01-01
Spinal cord injuries disrupt bidirectional communication between the patient’s brain and body. Here, we demonstrate a new approach for reproducing lower limb somatosensory feedback in paraplegics by remapping missing leg/foot tactile sensations onto the skin of patients’ forearms. A portable haptic display was tested in eight patients in a setup where the lower limbs were simulated using immersive virtual reality (VR). For six out of eight patients, the haptic display induced the realistic illusion of walking on three different types of floor surfaces: beach sand, a paved street or grass. Additionally, patients experienced the movements of the virtual legs during the swing phase or the sensation of the foot rolling on the floor while walking. Relying solely on this tactile feedback, patients reported the position of the avatar leg during virtual walking. Crossmodal interference between vision of the virtual legs and tactile feedback revealed that patients assimilated the virtual lower limbs as if they were their own legs. We propose that the addition of tactile feedback to neuroprosthetic devices is essential to restore a full lower limb perceptual experience in spinal cord injury (SCI) patients, and will ultimately, lead to a higher rate of prosthetic acceptance/use and a better level of motor proficiency. PMID:27640345
T1ρ MRI detects cartilage damage in asymptomatic individuals with a cam deformity.
Anwander, Helen; Melkus, Gerd; Rakhra, Kawan S; Beaulé, Paul E
2016-06-01
Hips with a cam deformity are at risk for early cartilage degeneration, mainly in the anterolateral region of the joint. T1ρ MRI is a described technique for assessment of proteoglycan content in hyaline cartilage and subsequently early cartilage damage. In this study, 1.5 Tesla T1ρ MRI was performed on 20 asymptomatic hips with a cam deformity and compared to 16 healthy control hips. Cam deformity was defined as an alpha angle at 1:30 o'clock position over 60° and/or at 3:00 o'clock position over 50.5°. Hip cartilage was segmented and divided into four regions of interest (ROIs): anterolateral, anteromedial, posterolateral, and posteromedial quadrants. Mean T1ρ value of the entire weight bearing cartilage in hips with a cam deformity (34.0 ± 4.6 ms) was significantly higher compared to control hips (31.3 ± 3.2 ms, p = 0.050). This difference reached significance in the anterolateral (p = 0.042) and posteromedial quadrants (p = 0.041). No significant correlation between the alpha angle and T1ρ values was detected. The results indicate cartilage damage occurs in hips with a cam deformity before symptoms occur. A significant difference in T1ρ values was found in the anterolateral quadrant, the area of direct engagement of the deformity, and in the posteromedial quadrant. To conclude, T1ρ MRI can detect early chondral damage in asymptomatic hips with a cam deformity. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1004-1009, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Tooth movements in foxhounds after one or two alveolar corticotomies.
Sanjideh, Payam A; Rossouw, P Emile; Campbell, Phillip M; Opperman, Lynne A; Buschang, Peter H
2010-02-01
The aim of this split-mouth experimental study was to determine (1) whether corticotomy procedures increase tooth movement and (2) the effects of a second corticotomy procedure after 4 weeks on the rate of tooth movement. The mandibular third and maxillary second premolars of five skeletally mature male foxhounds, approximately 2 years of age, were extracted. One randomly selected mandibular quadrant had buccal and lingual flaps and corticotomies performed around the second premolar; the other quadrant served as the control. Both maxillary quadrants had initial buccal flaps and corticotomies; one randomly selected quadrant had a second buccal flap surgery and corticotomy after 28 days. Coil springs (200 g force), along with a 0.045 mm diameter tube on a 0.040 mm diameter guiding wire, were used to move the mandibular second and maxillary third premolars. Records, including digital calliper measurements and radiographs, were taken on days 0, 10, 14, 28, 42, and 56. Multilevel statistical procedures were used to model longitudinal tooth movements. The radiographic measurements initially showed increasing mandibular tooth movement rates, peaking between 22 and 25 days, and then decelerating. Total mandibular tooth movements were significantly (P < 0.05) greater on the experimental (2.4 mm) than on the control (1.3 mm) side. The rates of maxillary tooth movement slowed over time, with significantly (P < 0.05) more overall tooth movement on the side that had two (2.3 mm) than one (2.0 mm) corticotomy procedure. Alveolar corticotomy significantly increases orthodontic tooth movement. Performing a second corticotomy procedure after 4 weeks maintained higher rates of tooth movement over a longer duration and produced greater overall tooth movement than performing just one initial corticotomy, but the difference was small.
Dehghani, Cirous; Srinivasan, Sangeetha; Edwards, Katie; Pritchard, Nicola; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2017-05-01
Reduced retinal nerve fiber layer (RNFL) thickness has been demonstrated in patients with diabetic peripheral neuropathy (DPN) in cross-sectional studies. This prospective study defines longitudinal alterations to the RNFL thickness in individuals with type 1 diabetes without (DPN-ve) and with (DPN+ve) DPN and in relation to risk factors for nerve damage. A cohort of 105 individuals with type 1 diabetes (20% DPN+ve) with predominantly mild or no retinopathy and no previous retinal photocoagulation underwent spectral-domain optical coherence tomography (SD-OCT) at baseline, 2 years, and 4 years. SD-OCT scans were acquired at 3.45-mm diameter around the optic nerve head and the overall RNFL and RNFL in the nasal, superior, temporal, and inferior quadrants were quantified. By including serial quantified RNFL parameters, linear mixed models were applied to assess the change in RNFL thickness over time and to explore the associations with other clinical variables. There was a significant decline in the overall RNFL thickness (-0.7 μm/y, P = 0.02) and RNFL in the superior quadrant (-1.9 μm/y, P < 0.01) in the DPN+ve group compared with DPN-ve group. The overall RNFL thickness and RNFL in the superior and nasal quadrants were inversely associated with age (β = -0.29, -0.41, and -0.29, respectively; P ≤ 0.02). Sex, retinopathy, diabetes duration, hemoglobin A1c, lipid profile, blood pressure, cigarette use, alcohol consumption, and body mass index did not show any significant effects (P > 0.05). Individuals with DPN showed a progressive RNFL thinning overall and in the superior quadrant, which was more pronounced in older individuals. There may be common pathways for retinal and peripheral neurodegeneration that are independent of conventional DPN risk factors.
Bertram, Felix; Hupp, Linus; Schnabl, Dagmar; Rudisch, Ansgar; Emshoff, Rüdiger
To determine a possible association between asymptomatic temporomandibular joint (TMJ) condylar erosion and the number of missing posterior teeth and their location, as well as the number of dental quadrants with missing posterior teeth. This case-control study involved 210 patients (male to female ratio = 98:112) aged 16-74 years, with 105 asymptomatic patients with TMJ condylar erosion and a control group of 105 patients without TMJ condylar erosion. Cone beam computed tomography images were evaluated to classify the severity of TMJ condylar erosion as grade 0 (absence of erosion), grade I (slight erosion), grade II (moderate erosion), or grade III (extensive erosion). The number of missing posterior teeth (mean ± standard deviation [SD]; 2.7 ± 2.4 vs 0.7 ± 1.2) (P < .001), number of dental quadrants with missing posterior teeth (1.5 ± 1.3 vs 0.6 ± 0.9) (P < .001), and bilateral location of missing posterior teeth (41 ± 39.0 vs 10 ± 9.5) (P < .001) were all significantly higher in patients with erosion than in those without erosion. The condylar erosion grade was significantly associated with the number of missing posterior teeth (odds ratio [OR] = 1.24; P = .006), the number of dental quadrants with missing posterior teeth (OR = 1.36; P = .006), and the bilateral occurrence of missing posterior teeth (OR = 3.03; P = .002). The findings from this study suggest a possible association between TMJ condylar erosion grades and the number of missing posterior teeth, the number of quadrants with missing posterior teeth, and the bilateral occurrence of missing posterior teeth.
Giant molecular filaments in the Milky Way. II. The fourth Galactic quadrant
NASA Astrophysics Data System (ADS)
Abreu-Vicente, J.; Ragan, S.; Kainulainen, J.; Henning, Th.; Beuther, H.; Johnston, K.
2016-05-01
Context. Filamentary structures are common morphological features of the cold, molecular interstellar medium (ISM). Recent studies have discovered massive, hundred-parsec-scale filaments that may be connected to the large-scale, Galactic spiral arm structure. Addressing the nature of these giant molecular filaments (GMFs) requires a census of their occurrence and properties. Aims: We perform a systematic search of GMFs in the fourth Galactic quadrant and determine their basic physical properties. Methods: We identify GMFs based on their dust extinction signatures in the near- and mid-infrared and the velocity structure probed by 13CO line emission. We use the 13CO line emission and ATLASGAL dust emission data to estimate the total and dense gas masses of the GMFs. We combine our sample with an earlier sample from literature and study the Galactic environment of the GMFs. Results: We identify nine GMFs in the fourth Galactic quadrant: six in the Centaurus spiral arm and three in inter-arm regions. Combining this sample with an earlier study using the same identification criteria in the first Galactic quadrant results in 16 GMFs, nine of which are located within spiral arms. The GMFs have sizes of 80-160 pc and 13CO-derived masses between 5-90 × 104M⊙. Their dense gas mass fractions are between 1.5-37%, which is higher in the GMFs connected to spiral arms. We also compare the different GMF-identification methods and find that emission and extinction-based techniques overlap only partially, thereby highlighting the need to use both to achieve a complete census. Table A.2 is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/590/A131
Starnes, Austin C; Huisingh, Carrie; McGwin, Gerald; Sloan, Kenneth R; Ablonczy, Zsolt; Smith, R Theodore; Curcio, Christine A; Ach, Thomas
2016-01-01
The human retinal pigment epithelium (RPE) is reportedly 3% bi-nucleated. The importance to human vision of multi-nucleated (MN)-RPE cells could be clarified with more data about their distribution in central retina. Nineteen human RPE-flatmounts (9 ≤ 51 years, 10 > 80 years) were imaged at 12 locations: 3 eccentricities (fovea, perifovea, near periphery) in 4 quadrants (superior, inferior, temporal, nasal). Image stacks of lipofuscin-attributable autofluorescence and phalloidin labeled F-actin cytoskeleton were obtained using a confocal fluorescence microscope. Nuclei were devoid of autofluorescence and were marked using morphometric software. Cell areas were approximated by Voronoi regions. Mean number of nuclei per cell among eccentricity/quadrant groups and by age were compared using Poisson and binominal regression models. A total of 11,403 RPE cells at 200 locations were analyzed: 94.66% mono-, 5.31% bi-, 0.02% tri-nucleate, and 0.01% with 5 nuclei. Age had no effect on number of nuclei. There were significant regional differences: highest frequencies of MN-cells were found at the perifovea (9.9%) and near periphery (6.8%). The fovea lacked MN-cells almost entirely. The nasal quadrant had significantly more MN-cells compared to other quadrants, at all eccentricities. This study demonstrates MN-RPE cells in human macula. MN-cells may arise due to endoreplication, cell fusion, or incomplete cell division. The topography of MN-RPE cells follows the topography of photoreceptors; with near-absence at the fovea (cones only) and high frequency at perifovea (highest rod density). This distribution might reflect specific requirements of retinal metabolism or other mechanisms addressable in further studies.
Reduced retinal nerve fiber layer (RNFL) thickness in ALS patients: a window to disease progression.
Rohani, Mohammad; Meysamie, Alipasha; Zamani, Babak; Sowlat, Mohammad Mahdi; Akhoundi, Fahimeh Haji
2018-04-30
To assess RNFL thickness in ALS patients and compare it to healthy controls, and to detect possible correlations between RNFL thickness in ALS patients and disease severity and duration. Study population consisted of ALS patients and age- and sex-matched controls. We used the revised ALS functional rating scale (ALSFRS-R) as a measure of disease severity. RNFL thickness in the four quadrants were measured with a spectral domain OCT (Topcon 3D, 2015). We evaluated 20 ALS patients (40 eyes) and 25 healthy matched controls. Average RNFL thickness in ALS patients was significantly reduced compared to controls (102.57 ± 13.46 compared to 97.11 ± 10.76, p 0.04). There was a significant positive correlation between the functional abilities of the patients based on the ALSFRS-R and average RNFL thickness and also RNFL thickness in most quadrants. A linear regression analysis proved that this correlation was independent of age. In ALS patients, RNFL thickness in the nasal quadrant of the left eyes was significantly reduced compared to the corresponding quadrant in the right eyes even after adjustment for multiplicity (85.80 ± 23.20 compared to 96.80 ± 16.96, p = 0.008). RNFL thickness in ALS patients is reduced compared to healthy controls. OCT probably could serve as a marker of neurodegeneration and progression of the disease in ALS patients. RNFL thickness is different among the right and left eyes of ALS patients pointing to the fact that asymmetric CNS involvement in ALS is not confined to the motor system.
Peripapillary Choroidal Thickness Variation With Age and Race in Normal Eyes
Rhodes, Lindsay A.; Huisingh, Carrie; Johnstone, John; Fazio, Massimo A.; Smith, Brandon; Wang, Lan; Clark, Mark; Downs, J. Crawford; Owsley, Cynthia; Girard, Michael J. A.; Mari, Jean Martial; Girkin, Christopher A.
2015-01-01
Purpose. This study examined the association between peripapillary choroidal thickness (PCT) with age and race in a group of African descent (AD) and European descent (ED) subjects with normal eyes. Methods. Optic nerve head images from enhanced depth imaging spectral-domain optical coherence tomography of 166 normal eyes from 84 subjects of AD and ED were manually delineated to identify the principal surfaces of Bruch's membrane (BM), Bruch's membrane opening (BMO), and anterior sclera (AS). Peripapillary choroidal thickness was measured between BM and AS at increasing distance away from BMO. The mean PCT was compared between AD and ED subjects and generalized estimating equation (GEE) regression analysis was used to examine the association between race and PCT overall, in each quadrant, and by distance from BMO. Models were adjusted for age, BMO area, and axial length in the regression analysis. Results. Overall, the mean PCT increased from 63.9 μm ± 18.1 at 0 to 250 μm to 170.3 μm ± 56.7 at 1500 to 2000 μm from BMO. Individuals of AD had a greater mean PCT than those of ED at all distances from BMO (P < 0.05 at each distance) and in each quadrant (P < 0.05 in each quadrant). Results from multivariate regression indicate that ED subjects had significantly lower PCT compared to AD overall and in all quadrants and distances from BMO. Increasing age was also significantly associated with a lower PCT in both ED and AD participants. Conclusions. Peripapillary choroidal thickness varies with race and age, as individuals of AD have a thicker peripapillary choroid than those of ED. (ClinicalTrials.gov number, NCT00221923.) PMID:25711640
Collagen Fiber Orientation and Dispersion in the Upper Cervix of Non-Pregnant and Pregnant Women
Myers, Kristin M.; Vink, Joy Y.; Wapner, Ronald J.; Hendon, Christine P.
2016-01-01
The structural integrity of the cervix in pregnancy is necessary for carrying a pregnancy until term, and the organization of human cervical tissue collagen likely plays an important role in the tissue’s structural function. Collagen fibers in the cervical extracellular matrix exhibit preferential directionality, and this collagen network ultrastructure is hypothesized to reorient and remodel during cervical softening and dilation at time of parturition. Within the cervix, the upper half is substantially loaded during pregnancy and is where the premature funneling starts to happen. To characterize the cervical collagen ultrastructure for the upper half of the human cervix, we imaged whole axial tissue slices from non-pregnant and pregnant women undergoing hysterectomy or cesarean hysterectomy respectively using optical coherence tomography (OCT) and implemented a pixel-wise fiber orientation tracking method to measure the distribution of fiber orientation. The collagen fiber orientation maps show that there are two radial zones and the preferential fiber direction is circumferential in a dominant outer radial zone. The OCT data also reveal that there are two anatomic regions with distinct fiber orientation and dispersion properties. These regions are labeled: Region 1—the posterior and anterior quadrants in the outer radial zone and Region 2—the left and right quadrants in the outer radial zone and all quadrants in the inner radial zone. When comparing samples from nulliparous vs multiparous women, no differences in these fiber properties were noted. Pregnant tissue samples exhibit an overall higher fiber dispersion and more heterogeneous fiber properties within the sample than non-pregnant tissue. Collectively, these OCT data suggest that collagen fiber dispersion and directionality may play a role in cervical remodeling during pregnancy, where distinct remodeling properties exist according to anatomical quadrant. PMID:27898677
Servomotor and Controller Having Large Dynamic Range
NASA Technical Reports Server (NTRS)
Alhorn, Dean C.; Howard, David E.; Smith, Dennis A.; Dutton, Ken; Paulson, M. Scott
2007-01-01
A recently developed micro-commanding rotational-position-control system offers advantages of less mechanical complexity, less susceptibility to mechanical resonances, less power demand, less bulk, less weight, and lower cost, relative to prior rotational-position-control systems based on stepping motors and gear drives. This system includes a digital-signal- processor (DSP)-based electronic controller, plus a shaft-angle resolver and a servomotor mounted on the same shaft. Heretofore, micro-stepping has usually been associated with stepping motors, but in this system, the servomotor is micro-commanded in response to rotational-position feedback from the shaft-angle resolver. The shaft-angle resolver is of a four-speed type chosen because it affords four times the resolution of a single-speed resolver. A key innovative aspect of this system is its position-feedback signal- conditioning circuits, which condition the resolver output signal for multiple ranges of rotational speed. In the preferred version of the system, two rotational- speed ranges are included, but any number of ranges could be added to expand the speed range or increase resolution in particular ranges. In the preferred version, the resolver output is conditioned with two resolver-to-digital converters (RDCs). One RDC is used for speeds from 0.00012 to 2.5 rpm; the other RDC is used for speeds of 2.5 to 6,000 rpm. For the lower speed range, the number of discrete steps of RDC output per revolution was set at 262,144 (4 quadrants at 16 bits per quadrant). For the higher speed range, the number of discrete steps per revolution was set at 4,096 (4 quadrants at 10 bits per quadrant).
Vasques, Paulo Henrique Diógenes; Pinheiro, Luiz Gonzaga Porto; de Meneses e Silva, João Marcos; de Moura Torres-de-Melo, José Ricardo; Pinheiro, Karine Bessa Porto; Rocha, João Ivo Xavier
2011-01-01
OBJECTIVES: This paper discusses the influence of a para-areolar incision in the upper outer quadrant of the breast on the location of the sentinel lymph node in a canine model. METHODS: The sentinel lymph node was marked with technetium-99, which was injected into the subareolar skin of the cranial breast. After the marker had migrated to the axilla, an arcuate para-areolar incision was performed 2 cm from the nipple in the upper outer quadrant. Patent blue dye was then injected above the upper border of the incision. At the marked site, an axillary incision was made, and the sentinel lymph node was identified by gamma probe and/or by direct visualization of the dye. The agreement between the two injection sites and the two sentinel lymph node identification methods was determined. Our sample group consisted of 40 cranial breasts of 23 adult females of the species Canis familiaris. The data were analyzed by using the McNemar test and by determining the kappa agreement coefficient. RESULT: Our findings showed that in 95% of the breasts, the sentinel lymph node was identified by the injection of technetium-99 m into the subareolar region, and in 82% of the cases, the sentinel lymph node was identified by the injection of patent blue dye above the upper border of the incision. The methods agreed 82% of the time. CONCLUSIONS: Previous para-areolar incisions in the upper outer quadrant did not interfere significantly with the biopsy when the dye was injected above the upper border of the incision. PMID:21915493
Laser Range and Bearing Finder with No Moving Parts
NASA Technical Reports Server (NTRS)
Bryan, Thomas C.; Howard, Richard T.; Book, Michael L.
2007-01-01
A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.
Ozge, Gokhan; Koylu, Mehmet Talay; Mumcuoglu, Tarkan; Gundogan, Fatih Cakir; Ozgonul, Cem; Ayyildiz, Onder; Kucukevcilioglu, Murat
2016-05-01
To compare retinal nerve fiber layer thickness (RNFLT) and choroidal thickness (ChT) measurements in eyes with pseudoexfoliative (PEX) glaucoma, PEX syndrome and healthy control eyes. Eighteen patients with PEX glaucoma in one eye and PEX syndrome in the fellow eye were included. The right eyes of thirty-nine age- and sex-matched healthy subjects were included as control group. All participants underwent a detailed biomicroscopic and funduscopic examination. RNFLT and ChT measurements were performed with a commercially available spectral-domain optical coherence tomography (SD-OCT). ChT measurements were performed by using enhanced depth imaging (EDI) mode. Patients with PEX underwent diurnal IOP measurements with 4-hour intervals before inclusion in the study. RNFLT results included the average measurement and 6 quadrants (temporal, inferotemporal, inferonasal, nasal, superonasal and supero-temporal). ChT measurements were performed in the subfoveal region and around the fovea (500µm and 1500 µm nasal and temporal to the fovea), as well as around the optic disc (average peripapillary and eight quadrants in the peripapillary region (temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, superior, supero-temporal)). RNFLT in all quadrants and average thickness were significantly lower in PEX glaucoma eyes compared to PEX syndrome eyes and healthy control eyes (p<0.001 for both). RNFLT comparisons between PEX syndrome and healthy control eyes did not show a significant difference (p>0.05) except the inferotemporal quadrant. ChT measurements were similar between groups (p>0.05). Thinning of the RNFL in association with unchanged ChT may mean that the presence of PEX material is a much more significant risk factor than choroidal changes in the progression of PEX syndrome to PEX glaucoma.
PP and PS interferometric images of near-seafloor sediments
Haines, S.S.
2011-01-01
I present interferometric processing examples from an ocean-bottom cable OBC dataset collected at a water depth of 800 m in the Gulf of Mexico. Virtual source and receiver gathers created through cross-correlation of full wavefields show clear PP reflections and PS conversions from near-seafloor layers of interest. Virtual gathers from wavefield-separated data show improved PP and PS arrivals. PP and PS brute stacks from the wavefield-separated data compare favorably with images from a non-interferometric processing flow. ?? 2011 Society of Exploration Geophysicists.
Archer, Charles J.; Blocksom, Michael A.; Ratterman, Joseph D.; Smith, Brian E.; Xue, Hanghon
2016-02-02
A parallel computer executes a number of tasks, each task includes a number of endpoints and the endpoints are configured to support collective operations. In such a parallel computer, establishing a group of endpoints receiving a user specification of a set of endpoints included in a global collection of endpoints, where the user specification defines the set in accordance with a predefined virtual representation of the endpoints, the predefined virtual representation is a data structure setting forth an organization of tasks and endpoints included in the global collection of endpoints and the user specification defines the set of endpoints without a user specification of a particular endpoint; and defining a group of endpoints in dependence upon the predefined virtual representation of the endpoints and the user specification.
Establishing a group of endpoints in a parallel computer
Archer, Charles J.; Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.; Xue, Hanhong
2016-02-02
A parallel computer executes a number of tasks, each task includes a number of endpoints and the endpoints are configured to support collective operations. In such a parallel computer, establishing a group of endpoints receiving a user specification of a set of endpoints included in a global collection of endpoints, where the user specification defines the set in accordance with a predefined virtual representation of the endpoints, the predefined virtual representation is a data structure setting forth an organization of tasks and endpoints included in the global collection of endpoints and the user specification defines the set of endpoints without a user specification of a particular endpoint; and defining a group of endpoints in dependence upon the predefined virtual representation of the endpoints and the user specification.
Parsimonious surface wave interferometry
NASA Astrophysics Data System (ADS)
Li, Jing; Hanafy, Sherif; Schuster, Gerard T.
2018-03-01
To decrease the recording time of a 2-D seismic survey from a few days to one hour or less, we present a parsimonious surface wave interferometry method. Interferometry allows for the creation of a large number of virtual shot gathers from just two reciprocal shot gathers by crosscoherence of trace pairs. Then, the virtual surface waves can be inverted for the S-wave velocity model by wave-equation dispersion inversion (WD). Synthetic and field data tests suggest that parsimonious WD (PWD) gives S-velocity tomograms that are comparable to those obtained from a conventional survey with a shot at each receiver. The limitation of PWD is that the virtual data lose some information so that the resolution of the S-velocity tomogram can be modestly lower than that of the S-velocity tomogram inverted from a conventional survey.
Virtual Mission Operations of Remote Sensors With Rapid Access To and From Space
NASA Technical Reports Server (NTRS)
Ivancic, William D.; Stewart, Dave; Walke, Jon; Dikeman, Larry; Sage, Steven; Miller, Eric; Northam, James; Jackson, Chris; Taylor, John; Lynch, Scott;
2010-01-01
This paper describes network-centric operations, where a virtual mission operations center autonomously receives sensor triggers, and schedules space and ground assets using Internet-based technologies and service-oriented architectures. For proof-of-concept purposes, sensor triggers are received from the United States Geological Survey (USGS) to determine targets for space-based sensors. The Surrey Satellite Technology Limited (SSTL) Disaster Monitoring Constellation satellite, the United Kingdom Disaster Monitoring Constellation (UK-DMC), is used as the space-based sensor. The UK-DMC s availability is determined via machine-to-machine communications using SSTL s mission planning system. Access to/from the UK-DMC for tasking and sensor data is via SSTL s and Universal Space Network s (USN) ground assets. The availability and scheduling of USN s assets can also be performed autonomously via machine-to-machine communications. All communication, both on the ground and between ground and space, uses open Internet standards.
Shema-Shiratzky, Shirley; Brozgol, Marina; Cornejo-Thumm, Pablo; Geva-Dayan, Karen; Rotstein, Michael; Leitner, Yael; Hausdorff, Jeffrey M; Mirelman, Anat
2018-05-17
To examine the feasibility and efficacy of a combined motor-cognitive training using virtual reality to enhance behavior, cognitive function and dual-tasking in children with Attention-Deficit/Hyperactivity Disorder (ADHD). Fourteen non-medicated school-aged children with ADHD, received 18 training sessions during 6 weeks. Training included walking on a treadmill while negotiating virtual obstacles. Behavioral symptoms, cognition and gait were tested before and after the training and at 6-weeks follow-up. Based on parental report, there was a significant improvement in children's social problems and psychosomatic behavior after the training. Executive function and memory were improved post-training while attention was unchanged. Gait regularity significantly increased during dual-task walking. Long-term training effects were maintained in memory and executive function. Treadmill-training augmented with virtual-reality is feasible and may be an effective treatment to enhance behavior, cognitive function and dual-tasking in children with ADHD.
Mucinous breast carcinoma with tall columnar cells.
Tsoukalas, N; Kiakou, M; Tolia, M; Kostakis, I D; Galanopoulos, M; Nakos, G; Tryfonopoulos, D; Kyrgias, G; Koumakis, G
2018-05-01
Mucinous carcinoma of the breast represents 1%-4% of all breast cancers. The World Health Organization classification divides this type of tumour into three different subtypes: mucinous carcinoma, mucinous carcinoma with tall columnar cells (mucinous cystadenocarcinoma and columnar cell mucinous carcinoma) and signet ring cell carcinoma. A 74-year-old woman presented a tumour with inflammatory features in the upper outer quadrant of her left breast, 7 cm in diameter. The core biopsy showed infiltrating ductal carcinoma of no specific type. The tumour-node-metastasis clinical staging was T4cN3M0 (Stage IIIC). She received neoadjuvant chemotherapy, underwent left mastectomy with radical axillary resection and subsequently received radiotherapy and chemotherapy. The histological examination of the surgical specimen revealed two solid tumors in the tail of Spence, which corresponded to adenocarcinoma with high columnar cells. The patient died 16 months after the diagnosis, suffering from pulmonary metastases and anterior chest wall infiltration. A review of the literature revealed only 21 reports of mucinous carcinoma of the breast with tall columnar cells, including our case. This is only the third time that the specific histological type of columnar cell mucinous carcinoma has been reported in the literature.
Was it less painful for knights? Influence of appearance on pain perception.
Weeth, A; Mühlberger, A; Shiban, Y
2017-11-01
Pain perception is a subjective experience shaped by different factors. In this study, we investigated the influence of a visually manipulated appearance of a virtual arm on pain perception. Specifically, we investigated how pain perception and vegetative skin responses were modified by inducing a virtual protection on the right arm by a virtual armour. Participants (n = 32) immersed in virtual reality embodied a virtual arm, which appeared in three different versions (uncovered, neutral or protected). During the virtual reality simulation, the participants received electrical stimulations of varying intensities. Skin conductance level (SCL) was analysed for the phase anticipation (from the moment the arm appeared until the electric stimulation) and perception of pain (after the electric stimulation). Pain ratings were acquired after the painful stimuli occurred. The sense of embodiment was positive for the unprotected and neutral condition and lower for the protected than for the neutral arm. Pain ratings were significantly decreased in the protected arm condition compared with both the unprotected arm and the neutral arm conditions. The SCL measurements showed no significant differences for the three arm types. According to the pain ratings, participants felt significantly less pain in the covered arm condition compared with the unprotected and the neutral arm condition. Subjective pain perception was decreased by a virtual protection of the arm in VR. The simplicity of the manipulation suggests possible practical uses in pain therapy by strengthening the patients' own capacities to influence their pain using simple cognitive manipulations via virtual reality. A virtual, covered arm causes differences in reported pain ratings. Physiological measurements do not confirm the findings. Visual information about body protection can have an impact on pain perception. © 2017 European Pain Federation - EFIC®.
The Southern H ii Region Discovery Survey (SHRDS): Pilot Survey
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, C.; Dickey, John M.; Jordan, C.
The Southern H ii Region Discovery Survey is a survey of the third and fourth quadrants of the Galactic plane that will detect radio recombination line (RRL) and continuum emission at cm-wavelengths from several hundred H ii region candidates using the Australia Telescope Compact Array. The targets for this survey come from the WISE Catalog of Galactic H ii Regions and were identified based on mid-infrared and radio continuum emission. In this pilot project, two different configurations of the Compact Array Broad Band receiver and spectrometer system were used for short test observations. The pilot surveys detected RRL emission frommore » 36 of 53 H ii region candidates, as well as seven known H ii regions that were included for calibration. These 36 recombination line detections confirm that the candidates are true H ii regions and allow us to estimate their distances.« less
Roder, D; Zorbas, H; Kollias, J; Pyke, C; Walters, D; Campbell, I; Taylor, C; Webster, F
2013-12-01
To investigate person, cancer and treatment determinants of immediate breast reconstruction (IBR) in Australia. Bi-variable and multi-variable analyses of the Quality Audit database. Of 12,707 invasive cancers treated by mastectomy circa 1998-2010, 8% had IBR. This proportion increased over time and reduced from 29% in women below 30 years to approximately 1% in those aged 70 years or more. Multiple regression indicated that other IBR predictors included: high socio-economic status; private health insurance; being asymptomatic; a metropolitan rather than inner regional treatment centre; higher surgeon case load; small tumour size; negative nodal status, positive progesterone receptor status; more cancer foci; multiple affected breast quadrants; synchronous bilateral cancer; not having neo-adjuvant chemotherapy, adjuvant radiotherapy or adjuvant hormone therapy; and receiving ovarian ablation. Variations in access to specialty services and other possible causes of variations in IBR rates need further investigation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Dasanu, Constantin A; Herzog, Thomas J
2009-01-01
Clear cell adenocarcinoma of the vagina and cervix were previously shown to be tumors occurring in female offspring exposed prenatally to diethylstilbestrol. This report describes the first clinical case of clear cell adenocarcinoma of the ovary linked to early diethylstilbestrol exposure in utero. A 45-year-old woman presented with a self-discovered lump in the lower abdominal quadrant. She underwent surgery and staging that revealed clear cell adenocarcinoma confined to the left ovary. Foci of high-grade squamous neoplastic proliferation, inflammation, and a paratubal cyst were also present on the pathology specimen. Medical records established unequivocally that the patient's mother received diethylstilbestrol therapy throughout the pregnancy. Our case is consistent with clear cell adenocarcinoma, probably related to diethylstilbestrol exposure in utero. It reinforces the need for continued vigilance in individuals prenatally exposed to this drug.
Bacteroides (Parabacteroides) distasonis splenic abscess in a sickle cell patient.
Al-Tawfiq, Jaffar A
2008-01-01
Splenic abscess is not an uncommon complication of patients with sickle-cell disease. Here we describe an 18 year-old boy with sickle cell disease and left upper quadrant abdominal pain. Computerized axial tomography revealed left sided free flowing pleural effusion and splenomegaly with liquefaction and possible gas formation. The splenic fluid grew an unusual organism known as Bacteroides distasonis. The patient received antimicrobial therapy and underwent a splenectomy with full recovery. The spleen was cystically infarcted and measured 22 x 16 x 5 cm. The capsule was thickened and covered by fibrinous exudate. Histopathologic examination of the spleen showed complete necrosis with reparative fibrosis. This case presents an unusual cause of splenic abscess due to Bacteroides distasonis with a subacute to chronic course. The presence of fever and left sided pleuritic chest pain in patients with sickle cell disease should raise the suspicion of splenic abscess.
Earth observation taken by the Expedition 29 crew
2011-11-16
ISS029-E-042846 (16 Nov. 2011) --- Parts of the U.S. and Mexico are seen in this image photographed by one of the Expedition 29 crew members from the International Space Station as it flew above the Pacific Ocean on Nov. 16, 2011. The Salton Sea is in the center of the frame, with the Gulf of Cortez, Mexico's Baja California and the Colorado River in the upper right quadrant. The Los Angeles Basin and Santa Catalina and San Clemente islands are at the bottom center edge of the image. Lake Mead and the Las Vegas area of Nevada even made it into the frame in the upper left quadrant.
A composite large-scale CO survey at high Galactic latitudes in the second quadrant
NASA Technical Reports Server (NTRS)
Heithausen, A.; Stacy, J. G.; Thaddeus, P.
1990-01-01
Surveys of the second quadrant of the Galaxy undertaken with the CfA 1.2-m telescope have been combined to produce a map of approximately 620 sq deg in the 2.6-mm CO (J = 1-0) line at high Galactic latitudes. CO was detected over about 13 percent of the region surveyed, an order of magnitude more gas by area than previously estimated. In contrast, only 26 percent of the area predicted by Desert et al. (1988) to contain molecular gas actually reveals CO, and about two-thirds of the clouds detected are not listed in their catalog of IR excess clouds.
Petrides, K V
2011-04-01
This article describes the basic principles of belief-importance (belimp) theory and tests them in two empirical studies. Belimp theory hypothesizes that personality traits confer a propensity to perceive convergences and divergences between our belief that we can attain goals and the importance that we place on these goals. Belief and importance are conceptualized as two coordinates, together defining the belimp plane. Four distinct quadrants can be identified within the belimp plane (Hubris, Motivation, Depression and Apathy), broadly corresponding to the personality dimensions of trait emotional intelligence, conscientiousness, neuroticism and introversion. Study 1 (N=365) defines the four quadrants in relation to goals about financial security and shows that they score differently on trait emotional intelligence, mood and somatic complaints. Study 2 (N=230) defines the quadrants in relation to goals about appearance and, separately, in relation to goals about popularity, and replicates the findings of the first study. Strategies and requirements for testing belimp theory are presented, as are a number of theoretical and practical advantages that it can potentially offer. © 2010 The Author. Scandinavian Journal of Psychology © 2010 The Scandinavian Psychological Associations.
Installation and airspeed effects on jet shock-associated noise
NASA Technical Reports Server (NTRS)
Vonglahn, U.; Goodykoontz, J.
1975-01-01
Experimental acoustic data are presented to illustrate, at model scale, the effect of varying the nozzle-wing installation on shock-associated noise, statically and with airspeed. The variation in installations included nozzle only, nozzle under-the-wing (with and without flaps deflected), and nozzle over-the-wing (unattached flow). The nozzles used were a conical and a 6-tube mixer nozzle with a cold-flow nozzle pressure ratio of 2.1. A 33-cm diameter free jet was used to simulate airspeed. With the nozzle only, shock wave noise dominated the spectra in the forward quadrant, while jet mixing noise dominated in the rearward quadrant. Similar trends were observed when a wing (flaps retracted) was included. Shock noise was attenuated with an over-the-wing configuration and increased with an under-the-wing configuration (due to reflection from the wing surface). With increasing flap deflection (under-the-wing configuration), the jet-flap interaction noise exceeded the shock noise and became dominant in both quadrants. The free jet results showed that airspeed had no effect on shock noise. The free jet noise data were corrected for convective amplification to approximate flight and comparisons between the various configurations are made.
NASA Astrophysics Data System (ADS)
Rafí, J. M.; Pellegrini, G.; Quirion, D.; Hidalgo, S.; Godignon, P.; Matilla, O.; Juanhuix, J.; Fontserè, A.; Molas, B.; Pothin, D.; Fajardo, P.
2017-01-01
Silicon photodiodes are very useful devices as X-ray beam monitors in synchrotron radiation beamlines. Owing to Si absorption, devices thinner than 10 μ m are needed to achieve transmission over 90% for energies above 10 keV . In this work, new segmented four-quadrant diodes for beam alignment purposes are fabricated on both ultrathin (10 μ m-thick) and bulk silicon substrates. Four-quadrant diodes implementing different design parameters as well as auxiliary test structures (single diodes and MOS capacitors) are studied. An extensive electrical characterization, including current-voltage (I-V) and capacitance-voltage (C-V) techniques, is carried out on non-irradiated and gamma-irradiated devices up to 100 Mrad doses. Special attention is devoted to the study of radiation-induced charge build-up in diode interquadrant isolation dielectric, as well as its impact on device interquadrant resistance. Finally, the devices have been characterized with an 8 keV laboratory X-ray source at 108 ph/s and in BL13-XALOC ALBA Synchroton beamline with 1011 ph/s and energies from 6 to 16 keV . Sensitivity, spatial resolution and uniformity of the devices have been evaluated.
Development of a model for whole brain learning of physiology.
Eagleton, Saramarie; Muller, Anton
2011-12-01
In this report, a model was developed for whole brain learning based on Curry's onion model. Curry described the effect of personality traits as the inner layer of learning, information-processing styles as the middle layer of learning, and environmental and instructional preferences as the outer layer of learning. The model that was developed elaborates on these layers by relating the personality traits central to learning to the different quadrants of brain preference, as described by Neethling's brain profile, as the inner layer of the onion. This layer is encircled by the learning styles that describe different information-processing preferences for each brain quadrant. For the middle layer, the different stages of Kolb's learning cycle are classified into the four brain quadrants associated with the different brain processing strategies within the information processing circle. Each of the stages of Kolb's learning cycle is also associated with a specific cognitive learning strategy. These two inner circles are enclosed by the circle representing the role of the environment and instruction on learning. It relates environmental factors that affect learning and distinguishes between face-to-face and technology-assisted learning. This model informs on the design of instructional interventions for physiology to encourage whole brain learning.
Measures of shoulder protraction and thoracolumbar rotation.
Schenkman, M; Laub, K C; Kuchibhatla, M; Ray, L; Shinberg, M
1997-05-01
Physical therapists need objective measures that can be used reliably with a variety of subject groups to document upper quadrant function. Two aspects of upper quadrant motion, shoulder protraction and thoracolumbar rotation, are assessed routinely in clinical practice, but no standard measurement techniques have been reported. We hypothesized that there would be significant differences, by age and state of health, for both shoulder protraction and thoracolumbar rotation. The purposes of this study were: 1) to develop measurement approaches for shoulder protraction and thoracolumbar rotation; 2) to determine if there are significant differences in these motions for four subject groups: healthy young, healthy elders, functionally limited elders, and people with Parkinson's disease; and 3) to describe between-rater and within-rater reliability for these measures. Fifty-five subjects participated in this investigation. All subjects were rated by a physical therapist and two research assistants. Using an analysis of variance followed by Scheffe's post hoc analysis, significant differences were demonstrated between the groups. Between-rater and within-rater reliability ranged from ICCs of 0.54 to 0.95. Clinicians can use these measures to quantify aspects of upper quadrant function treated routinely in physical therapy practice. These measures also have applicability for researchers.
Nonimpacted Third Molars Affect the Periodontal Status of Adjacent Teeth: A Cross-Sectional Study.
Li, Zhi-Bang; Qu, Hong-Lei; Zhou, Li-Na; Tian, Bei-Min; Gao, Li-Na; Chen, Fa-Ming
2017-07-01
Most previous studies of the effect of third molars (M3s) on the health of adjacent second molars (A-M2s) have focused on impacted M3s (I-M3s). The purpose of this study was to investigate whether nonimpacted M3 (N-M3s) could affect the periodontal status of A-M2s. In this cross-sectional study, patients (≥18 years) who had at least 1 quadrant with intact first and second molars and a nonimpacted or absent M3 were enrolled in this study. The periodontal measurements of M2 (6 sites) in the examined quadrants included the gingival index (GI), plaque index (PLI), probing pocket depth (PPD), clinical attachment level (CAL), gingival recession, and bleeding on probing (BOP). The mean GI, PLI, PPD, CAL, and BOP proportion and the proportion with at least 1 site with a PPD of at least 5 mm (PPD5 + ) were compared using the t test or χ 2 test. The association of PPD5 + (percentage) or BOP (percentage) with the presence of N-M3s was assessed using a 2-level logistic regression model (quadrant-based analysis). One hundred thirty-five patients (43.7% men; 40.6 ± 11.5 yr old) were enrolled in this study. Patients who had at least 1 quadrant with 3 intact molars and an N-M3 were enrolled in group A (105 patients), and patients who had at least 1 quadrant with intact first and second molars without an M3 were enrolled in group B (30 patients). The periodontal parameters (ie, GI, PLI, PPD, CAL, BOP, and PPD5 + ) were markedly greater in group A. When other factors associated with periodontal disease were controlled, N-M3s were associated with the PPD5 + (odds ratio = 6.7) and BOP (odds ratio = 4.0) of the A-M2s. Other factors positively associated with A-M2 PPD5 + were location on the mandible, age older than 35 years, and smoking. The presence of N-M3s is a potential risk factor for the development of periodontitis in A-M2s. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Integration of the virtual 3D model of a control system with the virtual controller
NASA Astrophysics Data System (ADS)
Herbuś, K.; Ociepka, P.
2015-11-01
Nowadays the design process includes simulation analysis of different components of a constructed object. It involves the need for integration of different virtual object to simulate the whole investigated technical system. The paper presents the issues related to the integration of a virtual 3D model of a chosen control system of with a virtual controller. The goal of integration is to verify the operation of an adopted object of in accordance with the established control program. The object of the simulation work is the drive system of a tunneling machine for trenchless work. In the first stage of work was created an interactive visualization of functioning of the 3D virtual model of a tunneling machine. For this purpose, the software of the VR (Virtual Reality) class was applied. In the elaborated interactive application were created adequate procedures allowing controlling the drive system of a translatory motion, a rotary motion and the drive system of a manipulator. Additionally was created the procedure of turning on and off the output crushing head, mounted on the last element of the manipulator. In the elaborated interactive application have been established procedures for receiving input data from external software, on the basis of the dynamic data exchange (DDE), which allow controlling actuators of particular control systems of the considered machine. In the next stage of work, the program on a virtual driver, in the ladder diagram (LD) language, was created. The control program was developed on the basis of the adopted work cycle of the tunneling machine. The element integrating the virtual model of the tunneling machine for trenchless work with the virtual controller is the application written in a high level language (Visual Basic). In the developed application was created procedures responsible for collecting data from the running, in a simulation mode, virtual controller and transferring them to the interactive application, in which is verified the operation of the adopted research object. The carried out work allowed foot the integration of the virtual model of the control system of the tunneling machine with the virtual controller, enabling the verification of its operation.
Hippocampus-Dependent Goal Localization by Head-Fixed Mice in Virtual Reality.
Sato, Masaaki; Kawano, Masako; Mizuta, Kotaro; Islam, Tanvir; Lee, Min Goo; Hayashi, Yasunori
2017-01-01
The demonstration of the ability of rodents to navigate in virtual reality (VR) has made it an important behavioral paradigm for studying spatially modulated neuronal activity in these animals. However, their behavior in such simulated environments remains poorly understood. Here, we show that encoding and retrieval of goal location memory in mice head-fixed in VR depends on the postsynaptic scaffolding protein Shank2 and the dorsal hippocampus. In our newly developed virtual cued goal location task, a head-fixed mouse moves from one end of a virtual linear track to seek rewards given at a target location along the track. The mouse needs to visually recognize the target location and stay there for a short period of time to receive the reward. Transient pharmacological blockade of fast glutamatergic synaptic transmission in the dorsal hippocampus dramatically and reversibly impaired performance of this task. Encoding and updating of virtual cued goal location memory was impaired in mice deficient in the postsynaptic scaffolding protein Shank2, a mouse model of autism that exhibits impaired spatial learning in a real environment. These results highlight the crucial roles of the dorsal hippocampus and postsynaptic protein complexes in spatial learning and navigation in VR.
Hippocampus-Dependent Goal Localization by Head-Fixed Mice in Virtual Reality
Kawano, Masako; Mizuta, Kotaro; Islam, Tanvir; Lee, Min Goo; Hayashi, Yasunori
2017-01-01
Abstract The demonstration of the ability of rodents to navigate in virtual reality (VR) has made it an important behavioral paradigm for studying spatially modulated neuronal activity in these animals. However, their behavior in such simulated environments remains poorly understood. Here, we show that encoding and retrieval of goal location memory in mice head-fixed in VR depends on the postsynaptic scaffolding protein Shank2 and the dorsal hippocampus. In our newly developed virtual cued goal location task, a head-fixed mouse moves from one end of a virtual linear track to seek rewards given at a target location along the track. The mouse needs to visually recognize the target location and stay there for a short period of time to receive the reward. Transient pharmacological blockade of fast glutamatergic synaptic transmission in the dorsal hippocampus dramatically and reversibly impaired performance of this task. Encoding and updating of virtual cued goal location memory was impaired in mice deficient in the postsynaptic scaffolding protein Shank2, a mouse model of autism that exhibits impaired spatial learning in a real environment. These results highlight the crucial roles of the dorsal hippocampus and postsynaptic protein complexes in spatial learning and navigation in VR. PMID:28484738
Manipulating presence influences the magnitude of virtual reality analgesia.
Hoffman, Hunter G; Sharar, Sam R; Coda, Barbara; Everett, John J; Ciol, Marcia; Richards, Todd; Patterson, David R
2004-09-01
Excessive pain during medical procedures performed in unanesthetized patients is frequently reported, but can be reduced with virtual reality (VR) distraction. Increasing the person's illusion of going into the virtual world may increase how effectively VR distracts pain. Healthy volunteers aged 18-20 years participated in a double-blind between-groups design. Each subject received a brief baseline thermal pain stimulus, and the same stimulus again minutes later with either a Low Tech or a High Tech VR distraction. Each subject provided subjective 0-10 ratings of cognitive, sensory and affective components of pain, and rated their illusion of going inside the virtual world. Subjects in the High Tech VR group reported a stronger illusion of going into the virtual world (VR presence) than subjects in the Low Tech VR group, (4.2 vs. 2.5, respectively, P = 0.009) and more pain reduction (reduction of worst pain is 3.1 for High Tech VR vs. 0.7 for Low Tech VR, P < 0.001). Across groups, the amount of pain reduction was positively and significantly correlated with VR presence levels reported by subjects ( r = 0.48 for 'worst pain', P < 0.005).
Virtual Reality Intervention for Older Women with Breast Cancer
SCHNEIDER, SUSAN M.; ELLIS, MATHEW; COOMBS, WILLIAM T.; SHONKWILER, ERIN L.; FOLSOM, LINDA C.
2013-01-01
This study examined the effects of a virtual reality distraction intervention on chemotherapy-related symptom distress levels in 16 women aged 50 and older. A cross-over design was used to answer the following research questions: (1) Is virtual reality an effective distraction intervention for reducing chemotherapy-related symptom distress levels in older women with breast cancer? (2) Does virtual reality have a lasting effect? Chemotherapy treatments are intensive and difficult to endure. One way to cope with chemotherapy-related symptom distress is through the use of distraction. For this study, a head-mounted display (Sony PC Glasstron PLM—S700) was used to display encompassing images and block competing stimuli during chemotherapy infusions. The Symptom Distress Scale (SDS), Revised Piper Fatigue Scale (PFS), and the State Anxiety Inventory (SAI) were used to measure symptom distress. For two matched chemotherapy treatments, one pre-test and two post-test measures were employed. Participants were randomly assigned to receive the VR distraction intervention during one chemotherapy treatment and received no distraction intervention (control condition) during an alternate chemotherapy treatment. Analysis using paired t-tests demonstrated a significant decrease in the SAI (p = 0.10) scores immediately following chemotherapy treatments when participants used VR. No significant changes were found in SDS or PFS values. There was a consistent trend toward improved symptoms on all measures 48 h following completion of chemotherapy. Evaluation of the intervention indicated that women thought the head mounted device was easy to use, they experienced no cybersickness, and 100% would use VR again. PMID:12855087
Piber, Dominique; Schultebraucks, Katharina; Mueller, Sven C; Deuter, Christian Eric; Wingenfeld, Katja; Otte, Christian
2016-12-01
Stress hormones such as cortisol are known to influence a wide range of cognitive functions, including hippocampal based spatial memory. In the brain, cortisol acts via two different receptors: the glucocorticoid (GR) and the mineralocorticoid receptor (MR). As the MR has a high density in the hippocampus, we examined the effects of pharmacological MR stimulation on spatial memory. Eighty healthy participants (40 women, 40 men, mean age=23.9years±SD=3.3) completed the virtual Morris Water Maze (vMWM) task to test spatial encoding and spatial memory retrieval after receiving 0.4mg fludrocortisone, a MR agonist, or placebo. There was no effect of MR stimulation on spatial encoding during the vMWM task. However, participants who received fludrocortisone exhibited improved spatial memory retrieval performance. There was neither a main effect of sex nor a sex-by-treatment interaction. In young healthy participants, MR stimulation improved hippocampal based spatial memory retrieval in a virtual Morris Water Maze task. Our study not only confirms the importance of MR function in spatial memory, but suggests beneficial effects of acute MR stimulation on spatial memory retrieval in humans. Copyright © 2016 Elsevier Inc. All rights reserved.
First virtual endocasts of adapiform primates.
Harrington, Arianna R; Silcox, Mary T; Yapuncich, Gabriel S; Boyer, Doug M; Bloch, Jonathan I
2016-10-01
Well-preserved crania of notharctine adapiforms from the Eocene of North America provide the best direct evidence available for inferring neuroanatomy and encephalization in early euprimates (crown primates). Virtual endocasts of the notharctines Notharctus tenebrosus (n = 3) and Smilodectes gracilis (n = 4) from the middle Eocene Bridger formation of Wyoming, and the late Eocene European adapid adapiform Adapis parisiensis (n = 1), were reconstructed from high-resolution X-ray computed tomography (CT) data. While the three species share many neuroanatomical similarities differentiating them from plesiadapiforms (stem primates) and extant euprimates, our sample of N. tenebrosus displays more variation than that of S. gracilis, possibly related to differences in the patterns of cranial sexual dimorphism or within-lineage evolution. Body masses predicted from associated teeth suggest that N. tenebrosus was larger and had a lower encephalization quotient (EQ) than S. gracilis, despite their close relationship and similar inferred ecologies. Meanwhile, body masses predicted from cranial length of the same specimens suggest that the two species were more similar, with overlapping body mass and EQ, although S. gracilis exhibits a range of EQs shifted upwards relative to that of N. tenebrosus. While associated data from other parts of the skeleton are mostly lacking for specimens included in this study, measurements for unassociated postcrania attributed to these species yield body mass and EQ estimates that are also more similar to each other than those based on teeth. Regardless of the body mass prediction method used, results suggest that the average EQ of adapiforms was similar to that of plesiadapiforms, only overlapped the lower quadrant for the range of extant strepsirrhines, and did not overlap with the range of extant haplorhines. However, structural changes evident in these endocasts suggest that early euprimates relied more on vision than olfaction relative to plesiadapiforms, despite having relatively small endocranial volumes compared to extant taxa. Copyright © 2016 Elsevier Ltd. All rights reserved.
1976-01-28
source-receiver geometry dynamics. For a given time instant, each of the subroutines outputs time variables ( emission time, arrival time...transmission loss, depression/elevation and azimuthal arrival angles, received frequency and range variables (range at emission time, range at arrival time...with the wind equal 24.5 kts. In the double bottom bounce regions, the emission angles (at the virtual surface source) are moderately small (15
Pot-Kolder, Roos; Veling, Wim; Geraets, Chris; van der Gaag, Mark
2016-01-13
Many patients with a psychotic disorder participate poorly in society. When psychotic disorders are in partial remission, feelings of paranoia, delusions of reference, social anxiety and self-stigmatization often remain at diminished severity and may lead to avoidance of places and people. Virtual reality exposure therapy (VRET) is an evidence-based treatment for several anxiety disorders. For patients with a psychotic disorder, the VRETp was developed to help them experience exposure to feared social situations. The present study aims to investigate the effects of VRETp on social participation in real life among patients with a psychotic disorder. The study is a single-blind randomized controlled trial with two conditions: the active condition, in which participants receive the virtual reality treatment together with treatment as usual (TAU), and the waiting list condition, in which participants receive TAU only. The two groups are compared at baseline, at 3 months posttreatment and at 6 months follow-up. All participants on the waiting list are also offered the virtual reality treatment after the follow-up measurements are completed. The primary outcome is social participation. Secondary outcomes are quality of life, interaction anxiety, depression and social functioning in general. Moderator and mediator analyses are conducted with stigma, cognitive schemata, cognitive biases, medication adherence, simulator sickness and presence in virtual reality. If effective, a cost-effectiveness analysis will be conducted. Results from the posttreatment measurement can be considered strong empirical indicators of the effectiveness of VRETp. The 6-month follow-up data may provide reliable documentation of the long-term effects of the treatment on the outcome variables. Data from pre-treatment and mid-treatment can be used to reveal possible pathways of change. Current Controlled Trials: ISRCTN12929657 . Date of registration: 8 September 2015.
Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K
2018-03-01
Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8-85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001). Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
National randomized controlled trial of virtual house calls for Parkinson disease.
Beck, Christopher A; Beran, Denise B; Biglan, Kevin M; Boyd, Cynthia M; Dorsey, E Ray; Schmidt, Peter N; Simone, Richard; Willis, Allison W; Galifianakis, Nicholas B; Katz, Maya; Tanner, Caroline M; Dodenhoff, Kristen; Aldred, Jason; Carter, Julie; Fraser, Andrew; Jimenez-Shahed, Joohi; Hunter, Christine; Spindler, Meredith; Reichwein, Suzanne; Mari, Zoltan; Dunlop, Becky; Morgan, John C; McLane, Dedi; Hickey, Patrick; Gauger, Lisa; Richard, Irene Hegeman; Mejia, Nicte I; Bwala, Grace; Nance, Martha; Shih, Ludy C; Singer, Carlos; Vargas-Parra, Silvia; Zadikoff, Cindy; Okon, Natalia; Feigin, Andrew; Ayan, Jean; Vaughan, Christina; Pahwa, Rajesh; Dhall, Rohit; Hassan, Anhar; DeMello, Steven; Riggare, Sara S; Wicks, Paul; Achey, Meredith A; Elson, Molly J; Goldenthal, Steven; Keenan, H Tait; Korn, Ryan; Schwarz, Heidi; Sharma, Saloni; Stevenson, E Anna; Zhu, William
2017-09-12
To determine whether providing remote neurologic care into the homes of people with Parkinson disease (PD) is feasible, beneficial, and valuable. In a 1-year randomized controlled trial, we compared usual care to usual care supplemented by 4 virtual visits via video conferencing from a remote specialist into patients' homes. Primary outcome measures were feasibility, as measured by the proportion who completed at least one virtual visit and the proportion of virtual visits completed on time; and efficacy, as measured by the change in the Parkinson's Disease Questionnaire-39, a quality of life scale. Secondary outcomes included quality of care, caregiver burden, and time and travel savings. A total of 927 individuals indicated interest, 210 were enrolled, and 195 were randomized. Participants had recently seen a specialist (73%) and were largely college-educated (73%) and white (96%). Ninety-five (98% of the intervention group) completed at least one virtual visit, and 91% of 388 virtual visits were completed. Quality of life did not improve in those receiving virtual house calls (0.3 points worse on a 100-point scale; 95% confidence interval [CI] -2.0 to 2.7 points; p = 0.78) nor did quality of care or caregiver burden. Each virtual house call saved patients a median of 88 minutes (95% CI 70-120; p < 0.0001) and 38 miles per visit (95% CI 36-56; p < 0.0001). Providing remote neurologic care directly into the homes of people with PD was feasible and was neither more nor less efficacious than usual in-person care. Virtual house calls generated great interest and provided substantial convenience. NCT02038959. This study provides Class III evidence that for patients with PD, virtual house calls from a neurologist are feasible and do not significantly change quality of life compared to in-person visits. The study is rated Class III because it was not possible to mask patients to visit type. © 2017 American Academy of Neurology.
High lateral resolution exploration using surface waves from noise records
NASA Astrophysics Data System (ADS)
Chávez-García, Francisco José Yokoi, Toshiaki
2016-04-01
Determination of the shear-wave velocity structure at shallow depths is a constant necessity in engineering or environmental projects. Given the sensitivity of Rayleigh waves to shear-wave velocity, subsoil structure exploration using surface waves is frequently used. Methods such as the spectral analysis of surface waves (SASW) or multi-channel analysis of surface waves (MASW) determine phase velocity dispersion from surface waves generated by an active source recorded on a line of geophones. Using MASW, it is important that the receiver array be as long as possible to increase the precision at low frequencies. However, this implies that possible lateral variations are discarded. Hayashi and Suzuki (2004) proposed a different way of stacking shot gathers to increase lateral resolution. They combined strategies used in MASW with the common mid-point (CMP) summation currently used in reflection seismology. In their common mid-point with cross-correlation method (CMPCC), they cross-correlate traces sharing CMP locations before determining phase velocity dispersion. Another recent approach to subsoil structure exploration is based on seismic interferometry. It has been shown that cross-correlation of a diffuse field, such as seismic noise, allows the estimation of the Green's Function between two receivers. Thus, a virtual-source seismic section may be constructed from the cross-correlation of seismic noise records obtained in a line of receivers. In this paper, we use the seismic interferometry method to process seismic noise records obtained in seismic refraction lines of 24 geophones, and analyse the results using CMPCC to increase the lateral resolution of the results. Cross-correlation of the noise records allows reconstructing seismic sections with virtual sources at each receiver location. The Rayleigh wave component of the Green's Functions is obtained with a high signal-to-noise ratio. Using CMPCC analysis of the virtual-source seismic lines, we are able to identify lateral variations of phase velocity inside the seismic line, and increase the lateral resolution compared with results of conventional analysis.
Virtual Reality: A Distraction Intervention for Chemotherapy
Schneider, Susan M.; Hood, Linda E.
2007-01-01
Purpose/Objectives To explore virtual reality (VR) as a distraction intervention to relieve symptom distress in adults receiving chemotherapy treatments for breast, colon, and lung cancer. Design Crossover design in which participants served as their own control. Setting Outpatient clinic at a comprehensive cancer center in the southeastern United States. Sample 123 adults receiving initial chemotherapy treatments. Methods Participants were randomly assigned to receive the VR distraction intervention during one chemotherapy treatment and then received no intervention (control) during an alternate matched chemotherapy treatment. The Adapted Symptom Distress Scale–2, Revised Piper Fatigue Scale, and State Anxiety Inventory were used to measure symptom distress. The Presence Questionnaire and an open-ended questionnaire were used to evaluate the subjects’ VR experience. The influence of type of cancer, age, and gender on symptom outcomes was explored. Mixed models were used to test for differences in levels of symptom distress. Main Research Variables Virtual reality and symptom distress. Findings Patients had an altered perception of time (p < 0.001) when using VR, which validates the distracting capacity of the intervention. Evaluation of the intervention indicated that patients believed the head-mounted device was easy to use, they experienced no cybersickness, and 82% would use VR again. However, analysis demonstrated no significant differences in symptom distress immediately or two days following chemotherapy treatments. Conclusions Patients stated that using VR made the treatment seem shorter and that chemotherapy treatments with VR were better than treatments without the distraction intervention. However, positive experiences did not result in a decrease in symptom distress. The findings support the idea that using VR can help to make chemotherapy treatments more tolerable, but clinicians should not assume that use of VR will improve chemotherapy-related symptoms. Implications for Nursing Patients found using VR during chemotherapy treatments to be enjoyable. VR is a feasible and cost-effective distraction intervention to implement in the clinical setting. PMID:17562631
Economic aspects of virtual water trade
NASA Astrophysics Data System (ADS)
Oki, Taikan; Yano, Shinjiro; Hanasaki, Naota
2017-04-01
Although water is rarely traded over long distances by itself, the total weight of the water consumed to produce traded commodities exceeds the weight of any other commodity traded in the world. This concept is known as virtual water trade. Although space-/time-/commodity-based quantification has been conducted extensively, the underlying causes of this peculiar feature have thus far received little exploration. Here, we use estimates of water consumption from a global hydrological model and statistical data related to food trade to elucidate three facts that explain the fundamental nature of virtual water trade with respect to alleviating water scarcity. First, we quantitatively illustrate the unique position of water among commodities based on its unit price and quantity of sales. Water has an extremely low unit price, and a tremendous volume of water is consumed per person each day. Second, we show that rich but water-scarce countries tend to reduce local water consumption by importing virtual water. Third, we demonstrate that nations characterized by net virtual water exports have higher water resources and income per capita and that no countries fall below a certain threshold with respect to both GDP and water resources. These points suggest that the virtual water trade is explained by economic characteristics of water and that sustainable development depends on promoting the co-development of poverty alleviation and water resource development.
Design and evaluation of a simulation for pediatric dentistry in virtual worlds.
Papadopoulos, Lazaros; Pentzou, Afroditi-Evaggelia; Louloudiadis, Konstantinos; Tsiatsos, Thrasyvoulos-Konstantinos
2013-10-29
Three-dimensional virtual worlds are becoming very popular among educators in the medical field. Virtual clinics and patients are already used for case study and role play in both undergraduate and continuing education levels. Dental education can also take advantage of the virtual world's pedagogical features in order to give students the opportunity to interact with virtual patients (VPs) and practice in treatment planning. The objective of this study was to design and evaluate a virtual patient as a supplemental teaching tool for pediatric dentistry. A child VP, called Erietta, was created by utilizing the programming and building tools that online virtual worlds offer. The case is about an eight-year old girl visiting the dentist with her mother for the first time. Communication techniques such as Tell-Show-Do and parents' interference management were the basic elements of the educational scenario on which the VP was based. An evaluation of the simulation was made by 103 dental students in their fourth year of study. Two groups were formed: an experimental group which was exposed to the simulation (n=52) and a control group which did not receive the simulation (n=51). At the end, both groups were asked to complete a knowledge questionnaire and the results were compared. A statistically significant difference between the two groups was found by applying a t test for independent samples (P<.001), showing a positive learning effect from the VP. The majority of the participants evaluated the aspects of the simulation very positively while 69% (36/52) of the simulation group expressed their preference for using this module as an additional teaching tool. This study demonstrated that a pediatric dentistry VP built in a virtual world offers significant learning potential when used as a supplement to the traditional teaching techniques.
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm.
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A; Przekwas, Andrzej; Francis, Joseph T; Lytton, William W
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics.