Virtual temporal bone dissection system: OSU virtual temporal bone system: development and testing.
Wiet, Gregory J; Stredney, Don; Kerwin, Thomas; Hittle, Bradley; Fernandez, Soledad A; Abdel-Rasoul, Mahmoud; Welling, D Bradley
2012-03-01
The objective of this project was to develop a virtual temporal bone dissection system that would provide an enhanced educational experience for the training of otologic surgeons. A randomized, controlled, multi-institutional, single-blinded validation study. The project encompassed four areas of emphasis: structural data acquisition, integration of the system, dissemination of the system, and validation. Structural acquisition was performed on multiple imaging platforms. Integration achieved a cost-effective system. Dissemination was achieved on different levels including casual interest, downloading of software, and full involvement in development and validation studies. A validation study was performed at eight different training institutions across the country using a two-arm randomized trial where study subjects were randomized to a 2-week practice session using either the virtual temporal bone or standard cadaveric temporal bones. Eighty subjects were enrolled and randomized to one of the two treatment arms; 65 completed the study. There was no difference between the two groups using a blinded rating tool to assess performance after training. A virtual temporal bone dissection system has been developed and compared to cadaveric temporal bones for practice using a multicenter trial. There was no statistical difference between practice on the current simulator compared to practice on human cadaveric temporal bones. Further refinements in structural acquisition and interface design have been identified, which can be implemented prior to full incorporation into training programs and used for objective skills assessment. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Fang, Te-Yung; Wang, Pa-Chun; Liu, Chih-Hsien; Su, Mu-Chun; Yeh, Shih-Ching
2014-02-01
Virtual reality simulation training may improve knowledge of anatomy and surgical skills. We evaluated a 3-dimensional, haptic, virtual reality temporal bone simulator for dissection training. The subjects were 7 otolaryngology residents (3 training sessions each) and 7 medical students (1 training session each). The virtual reality temporal bone simulation station included a computer with software that was linked to a force-feedback hand stylus, and the system recorded performance and collisions with vital anatomic structures. Subjects performed virtual reality dissections and completed questionnaires after the training sessions. Residents and students had favorable responses to most questions of the technology acceptance model (TAM) questionnaire. The average TAM scores were above neutral for residents and medical students in all domains, and the average TAM score for residents was significantly higher for the usefulness domain and lower for the playful domain than students. The average satisfaction questionnaire for residents showed that residents had greater overall satisfaction with cadaver temporal bone dissection training than training with the virtual reality simulator or plastic temporal bone. For medical students, the average comprehension score was significantly increased from before to after training for all anatomic structures. Medical students had significantly more collisions with the dura than residents. The residents had similar mean performance scores after the first and third training sessions for all dissection procedures. The virtual reality temporal bone simulator provided satisfactory training for otolaryngology residents and medical students. Copyright © 2013. Published by Elsevier Ireland Ltd.
Lui, Justin T; Hoy, Monica Y
2017-06-01
Background The increasing prevalence of virtual reality simulation in temporal bone surgery warrants an investigation to assess training effectiveness. Objectives To determine if temporal bone simulator use improves mastoidectomy performance. Data Sources Ovid Medline, Embase, and PubMed databases were systematically searched per the PRISMA guidelines. Review Methods Inclusion criteria were peer-reviewed publications that utilized quantitative data of mastoidectomy performance following the use of a temporal bone simulator. The search was restricted to human studies published in English. Studies were excluded if they were in non-peer-reviewed format, were descriptive in nature, or failed to provide surgical performance outcomes. Meta-analysis calculations were then performed. Results A meta-analysis based on the random-effects model revealed an improvement in overall mastoidectomy performance following training on the temporal bone simulator. A standardized mean difference of 0.87 (95% CI, 0.38-1.35) was generated in the setting of a heterogeneous study population ( I 2 = 64.3%, P < .006). Conclusion In the context of a diverse population of virtual reality simulation temporal bone surgery studies, meta-analysis calculations demonstrate an improvement in trainee mastoidectomy performance with virtual simulation training.
Assessment of skills using a virtual reality temporal bone surgery simulator.
Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E
2013-08-01
Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.
A review of simulation platforms in surgery of the temporal bone.
Bhutta, M F
2016-10-01
Surgery of the temporal bone is a high-risk activity in an anatomically complex area. Simulation enables rehearsal of such surgery. The traditional simulation platform is the cadaveric temporal bone, but in recent years other simulation platforms have been created, including plastic and virtual reality platforms. To undertake a review of simulation platforms for temporal bone surgery, specifically assessing their educational value in terms of validity and in enabling transition to surgery. Systematic qualitative review. Search of the Pubmed, CINAHL, BEI and ERIC databases. Assessment of reported outcomes in terms of educational value. A total of 49 articles were included, covering cadaveric, animal, plastic and virtual simulation platforms. Cadaveric simulation is highly rated as an educational tool, but there may be a ceiling effect on educational outcomes after drilling 8-10 temporal bones. Animal models show significant anatomical variation from man. Plastic temporal bone models offer much potential, but at present lack sufficient anatomical or haptic validity. Similarly, virtual reality platforms lack sufficient anatomical or haptic validity, but with technological improvements they are advancing rapidly. At present, cadaveric simulation remains the best platform for training in temporal bone surgery. Technological advances enabling improved materials or modelling mean that in the future plastic or virtual platforms may become comparable to cadaveric platforms, and also offer additional functionality including patient-specific simulation from CT data. © 2015 John Wiley & Sons Ltd.
LINKE, R.; LEICHTLE, A.; SHEIKH, F.; SCHMIDT, C.; FRENZEL, H.; GRAEFE, H.; WOLLENBERG, B.; MEYER, J.E.
2013-01-01
SUMMARY Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear. PMID:24043916
Virtual temporal bone: an interactive 3-dimensional learning aid for cranial base surgery.
Kockro, Ralf A; Hwang, Peter Y K
2009-05-01
We have developed an interactive virtual model of the temporal bone for the training and teaching of cranial base surgery. The virtual model was based on the tomographic data of the Visible Human Project. The male Visible Human's computed tomographic data were volumetrically reconstructed as virtual bone tissue, and the individual photographic slices provided the basis for segmentation of the middle and inner ear structures, cranial nerves, vessels, and brainstem. These structures were created by using outlining and tube editing tools, allowing structural modeling either directly on the basis of the photographic data or according to information from textbooks and cadaver dissections. For training and teaching, the virtual model was accessed in the previously described 3-dimensional workspaces of the Dextroscope or Dextrobeam (Volume Interactions Pte, Ltd., Singapore), whose interfaces enable volumetric exploration from any perspective and provide virtual tools for drilling and measuring. We have simulated several cranial base procedures including approaches via the floor of the middle fossa and the lateral petrous bone. The virtual model suitably illustrated the core facts of anatomic spatial relationships while simulating different stages of bone drilling along a variety of surgical corridors. The system was used for teaching during training courses to plan and discuss operative anatomy and strategies. The Virtual Temporal Bone and its surrounding 3-dimensional workspace provide an effective way to study the essential surgical anatomy of this complex region and to teach and train operative strategies, especially when used as an adjunct to cadaver dissections.
Mastoidectomy performance assessment of virtual simulation training using final-product analysis.
Andersen, Steven A W; Cayé-Thomasen, Per; Sørensen, Mads S
2015-02-01
The future development of integrated automatic assessment in temporal bone virtual surgical simulators calls for validation against currently established assessment tools. This study aimed to explore the relationship between mastoidectomy final-product performance assessment in virtual simulation and traditional dissection training. Prospective trial with blinding. A total of 34 novice residents performed a mastoidectomy on the Visible Ear Simulator and on a cadaveric temporal bone. Two blinded senior otologists assessed the final-product performance using a modified Welling scale. The simulator gathered basic metrics on time, steps, and volumes in relation to the on-screen tutorial and collisions with vital structures. Substantial inter-rater reliability (kappa = 0.77) for virtual simulation and moderate inter-rater reliability (kappa = 0.59) for dissection final-product assessment was found. The simulation and dissection performance scores had significant correlation (P = .014). None of the basic simulator metrics correlated significantly with the final-product score except for number of steps completed in the simulator. A modified version of a validated final-product performance assessment tool can be used to assess mastoidectomy on virtual temporal bones. Performance assessment of virtual mastoidectomy could potentially save the use of cadaveric temporal bones for more advanced training when a basic level of competency in simulation has been achieved. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Supporting skill acquisition in cochlear implant surgery through virtual reality simulation.
Copson, Bridget; Wijewickrema, Sudanthi; Zhou, Yun; Piromchai, Patorn; Briggs, Robert; Bailey, James; Kennedy, Gregor; O'Leary, Stephen
2017-03-01
To evaluate the effectiveness of a virtual reality (VR) temporal bone simulator in training cochlear implant surgery. We compared the performance of 12 otolaryngology registrars conducting simulated cochlear implant surgery before (pre-test) and after (post-tests) receiving training on a VR temporal bone surgery simulator with automated performance feedback. The post-test tasks were two temporal bones, one that was a mirror image of the temporal bone used as a pre-test and the other, a novel temporal bone. Participant performances were assessed by an otologist with a validated cochlear implant competency assessment tool. Structural damage was derived from an automatically generated simulator metric and compared between time points. Wilcoxon signed-rank test showed that there was a significant improvement with a large effect size in the total performance scores between the pre-test (PT) and both the first and second post-tests (PT1, PT2) (PT-PT1: P = 0.007, r = 0.78, PT-PT2: P = 0.005, r = 0.82). The results of the study indicate that VR simulation with automated guidance can effectively be used to train surgeons in training complex temporal bone surgeries such as cochlear implantation.
Face and content validation of a virtual reality temporal bone simulator.
Arora, Asit; Khemani, Sam; Tolley, Neil; Singh, Arvind; Budge, James; Varela, David A Diaz Voss; Francis, Howard W; Darzi, Ara; Bhatti, Nasir I
2012-03-01
To validate the VOXEL-MAN TempoSurg simulator for temporal bone dissection. Prospective international study. Otolaryngology departments of 2 academic health care institutions in the United Kingdom and United States. Eighty-five subjects were recruited consisting of an experienced and referent group. Participants performed a standardized familiarization session and temporal bone dissection task. Realism, training effectiveness, and global impressions were evaluated across 21 domains using a 5-point Likert-type scale. A score of 4 was the minimum threshold for acceptability. The experienced group comprised 25 otolaryngology trainers who had performed 150 mastoid operations. The referent group comprised 60 trainees (mean otolaryngology experience of 2.9 years). Familiarization took longer in the experienced group (P = .01). User-friendliness was positively rated (mean score 4.1). Seventy percent of participants rated anatomical appearance as acceptable. Trainers rated drill ergonomics worse than did trainees (P = .01). Simulation temporal bone training scored highly (mean score 4.3). Surgical anatomy, drill navigation, and hand-eye coordination accounted for this. Trainees were more likely to recommend temporal bone simulation to a colleague than were trainers (P = .01). Transferability of skills to the operating room was undecided (mean score 3.5). Realism of the VOXEL-MAN virtual reality temporal bone simulator is suboptimal in its current version. Nonetheless, it represents a useful adjunct to existing training methods and is particularly beneficial for novice surgeons before performing cadaveric temporal bone dissection. Improvements in realism, specifically drill ergonomics and visual-spatial perception during deeper temporal bone dissection, are warranted.
Virtual reality case-specific rehearsal in temporal bone surgery: a preliminary evaluation.
Arora, Asit; Swords, Chloe; Khemani, Sam; Awad, Zaid; Darzi, Ara; Singh, Arvind; Tolley, Neil
2014-01-01
1. To investigate the feasibility of performing case-specific surgical rehearsal using a virtual reality temporal bone simulator. 2. To identify potential clinical applications in temporal bone surgery. Prospective assessment study. St Mary's Hospital, Imperial College NHS Trust, London UK. Sixteen participants consisting of a trainer and trainee group. Twenty-four cadaver temporal bones were CT-scanned and uploaded onto the Voxelman simulator. Sixteen participants performed a 90-min temporal bone dissection on the generic simulation model followed by 3 dissection tasks on the case simulation and cadaver models. Case rehearsal was assessed for feasibility. Clinical applications and usefulness were evaluated using a 5-point Likert-type scale. The upload process required a semi-automated system. Average time for upload was 20 min. Suboptimal reconstruction occurred in 21% of cases arising when the mastoid process and ossicular chain were not captured (n = 2) or when artefact was generated (n = 3). Case rehearsal rated highly (Likert score >4) for confidence (75%), facilitating planning (75%) and training (94%). Potential clinical applications for case rehearsal include ossicular chain surgery, cochlear implantation and congenital anomalies. Case rehearsal of cholesteatoma surgery is not possible on the current platform due to suboptimal soft tissue representation. The process of uploading CT data onto a virtual reality temporal bone simulator to perform surgical rehearsal is feasible using a semi-automated system. Further clinical evaluation is warranted to assess the benefit of performing patient-specific surgical rehearsal in selected procedures. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Using a virtual reality temporal bone simulator to assess otolaryngology trainees.
Zirkle, Molly; Roberson, David W; Leuwer, Rudolf; Dubrowski, Adam
2007-02-01
The objective of this study is to determine the feasibility of computerized evaluation of resident performance using hand motion analysis on a virtual reality temporal bone (VR TB) simulator. We hypothesized that both computerized analysis and expert ratings would discriminate the performance of novices from experienced trainees. We also hypothesized that performance on the virtual reality temporal bone simulator (VR TB) would differentiate based on previous drilling experience. The authors conducted a randomized, blind assessment study. Nineteen volunteers from the Otolaryngology-Head and Neck Surgery training program at the University of Toronto drilled both a cadaveric TB and a simulated VR TB. Expert reviewers were asked to assess operative readiness of the trainee based on a blind video review of their performance. Computerized hand motion analysis of each participant's performance was conducted. Expert raters were able to discriminate novices from experienced trainees (P < .05) on cadaveric temporal bones, and there was a trend toward discrimination on VR TB performance. Hand motion analysis showed that experienced trainees had better movement economy than novices (P < .05) on the VR TB. Performance, as measured by hand motion analysis on the VR TB simulator, reflects trainees' previous drilling experience. This study suggests that otolaryngology trainees could accomplish initial temporal bone training on a VR TB simulator, which can provide feedback to the trainee, and may reduce the need for constant faculty supervision and evaluation.
Virtual reality simulation training in Otolaryngology.
Arora, Asit; Lau, Loretta Y M; Awad, Zaid; Darzi, Ara; Singh, Arvind; Tolley, Neil
2014-01-01
To conduct a systematic review of the validity data for the virtual reality surgical simulator platforms available in Otolaryngology. Ovid and Embase databases searched July 13, 2013. Four hundred and nine abstracts were independently reviewed by 2 authors. Thirty-six articles which fulfilled the search criteria were retrieved and viewed in full text. These articles were assessed for quantitative data on at least one aspect of face, content, construct or predictive validity. Papers were stratified by simulator, sub-specialty and further classified by the validation method used. There were 21 articles reporting applications for temporal bone surgery (n = 12), endoscopic sinus surgery (n = 6) and myringotomy (n = 3). Four different simulator platforms were validated for temporal bone surgery and two for each of the other surgical applications. Face/content validation represented the most frequent study type (9/21). Construct validation studies performed on temporal bone and endoscopic sinus surgery simulators showed that performance measures reliably discriminated between different experience levels. Simulation training improved cadaver temporal bone dissection skills and operating room performance in sinus surgery. Several simulator platforms particularly in temporal bone surgery and endoscopic sinus surgery are worthy of incorporation into training programmes. Standardised metrics are necessary to guide curriculum development in Otolaryngology. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Locketz, Garrett D; Lui, Justin T; Chan, Sonny; Salisbury, Kenneth; Dort, Joseph C; Youngblood, Patricia; Blevins, Nikolas H
2017-06-01
Objective To evaluate the effect of anatomy-specific virtual reality (VR) surgical rehearsal on surgeon confidence and temporal bone dissection performance. Study Design Prospective pre- and poststudy of a novel virtual surgical rehearsal platform. Setting Academic otolaryngology-head and neck surgery residency training programs. Subjects and Methods Sixteen otolaryngology-head and neck surgery residents from 2 North American training institutions were recruited. Surveys were administered to assess subjects' baseline confidence in performing 12 subtasks of cortical mastoidectomy with facial recess. A cadaver temporal bone was randomly assigned to each subject. Cadaver specimens were scanned with a clinical computed tomography protocol, allowing the creation of anatomy-specific models for use in a VR surgical rehearsal platform. Subjects then rehearsed a virtual mastoidectomy on data sets derived from their specimens. Surgical confidence surveys were administered again. Subjects then dissected assigned cadaver specimens, which were blindly graded with a modified Welling scale. A final survey assessed the perceived utility of rehearsal on dissection performance. Results Of 16 subjects, 14 (87.5%) reported a significant increase in overall confidence after conducting an anatomy-specific VR rehearsal. A significant correlation existed between perceived utility of rehearsal and confidence improvement. The effect of rehearsal on confidence was dependent on trainee experience and the inherent difficulty of the surgical subtask. Postrehearsal confidence correlated strongly with graded dissection performance. Subjects rated anatomy-specific rehearsal as having a moderate to high contribution to their dissection performance. Conclusion Anatomy-specific virtual rehearsal improves surgeon confidence in performing mastoid dissection, dependent on surgeon experience and task difficulty. The subjective confidence gained through rehearsal correlates positively with subsequent objective dissection performance.
Kahrs, Lüder Alexander; Labadie, Robert Frederick
2013-01-01
Cadaveric dissection of temporal bone anatomy is not always possible or feasible in certain educational environments. Volume rendering using CT and/or MRI helps understanding spatial relationships, but they suffer in nonrealistic depictions especially regarding color of anatomical structures. Freely available, nonstained histological data sets and software which are able to render such data sets in realistic color could overcome this limitation and be a very effective teaching tool. With recent availability of specialized public-domain software, volume rendering of true-color, histological data sets is now possible. We present both feasibility as well as step-by-step instructions to allow processing of publicly available data sets (Visible Female Human and Visible Ear) into easily navigable 3-dimensional models using free software. Example renderings are shown to demonstrate the utility of these free methods in virtual exploration of the complex anatomy of the temporal bone. After exploring the data sets, the Visible Ear appears more natural than the Visible Human. We provide directions for an easy-to-use, open-source software in conjunction with freely available histological data sets. This work facilitates self-education of spatial relationships of anatomical structures inside the human temporal bone as well as it allows exploration of surgical approaches prior to cadaveric testing and/or clinical implementation. Copyright © 2013 S. Karger AG, Basel.
Integration of High-resolution Data for Temporal Bone Surgical Simulations
Wiet, Gregory J.; Stredney, Don; Powell, Kimerly; Hittle, Brad; Kerwin, Thomas
2016-01-01
Purpose To report on the state of the art in obtaining high-resolution 3D data of the microanatomy of the temporal bone and to process that data for integration into a surgical simulator. Specifically, we report on our experience in this area and discuss the issues involved to further the field. Data Sources Current temporal bone image acquisition and image processing established in the literature as well as in house methodological development. Review Methods We reviewed the current English literature for the techniques used in computer-based temporal bone simulation systems to obtain and process anatomical data for use within the simulation. Search terms included “temporal bone simulation, surgical simulation, temporal bone.” Articles were chosen and reviewed that directly addressed data acquisition and processing/segmentation and enhancement with emphasis given to computer based systems. We present the results from this review in relationship to our approach. Conclusions High-resolution CT imaging (≤100μm voxel resolution), along with unique image processing and rendering algorithms, and structure specific enhancement are needed for high-level training and assessment using temporal bone surgical simulators. Higher resolution clinical scanning and automated processes that run in efficient time frames are needed before these systems can routinely support pre-surgical planning. Additionally, protocols such as that provided in this manuscript need to be disseminated to increase the number and variety of virtual temporal bones available for training and performance assessment. PMID:26762105
Mixed reality temporal bone surgical dissector: mechanical design.
Hochman, Jordan Brent; Sepehri, Nariman; Rampersad, Vivek; Kraut, Jay; Khazraee, Milad; Pisa, Justyn; Unger, Bertram
2014-08-08
The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill's passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator.
The effect of fidelity: how expert behavior changes in a virtual reality environment.
Ioannou, Ioanna; Avery, Alex; Zhou, Yun; Szudek, Jacek; Kennedy, Gregor; O'Leary, Stephen
2014-09-01
We compare the behavior of expert surgeons operating on the "gold standard" of simulation-the cadaveric temporal bone-against a high-fidelity virtual reality (VR) simulation. We aim to determine whether expert behavior changes within the virtual environment and to understand how the fidelity of simulation affects users' behavior. Five expert otologists performed cortical mastoidectomy and cochleostomy on a human cadaveric temporal bone and a VR temporal bone simulator. Hand movement and video recordings were used to derive a range of measures, to facilitate an analysis of surgical technique, and to compare expert behavior between the cadaveric and simulator environments. Drilling time was similar across the two environments. Some measures such as total time and burr change count differed predictably due to the ease of switching burrs within the simulator. Surgical strokes were generally longer in distance and duration in VR, but these measures changed proportionally to cadaveric measures across the stages of the procedure. Stroke shape metrics differed, which was attributed to the modeling of burr behavior within the simulator. This will be corrected in future versions. Slight differences in drill interaction between a virtual environment and the real world can have measurable effects on surgical technique, particularly in terms of stroke length, duration, and curvature. It is important to understand these effects when designing and implementing surgical training programs based on VR simulation--and when improving the fidelity of VR simulators to facilitate use of a similar technique in both real and simulated situations. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Handzel, Ophir; Wang, Haobing; Fiering, Jason; Borenstein, Jeffrey T.; Mescher, Mark J.; Leary Swan, Erin E.; Murphy, Brian A.; Chen, Zhiqiang; Peppi, Marcello; Sewell, William F.; Kujawa, Sharon G.; McKenna, Michael J.
2009-01-01
Temporal bone implants can be used to electrically stimulate the auditory nerve, to amplify sound, to deliver drugs to the inner ear and potentially for other future applications. The implants require storage space and access to the middle or inner ears. The most acceptable space is the cavity created by a canal wall up mastoidectomy. Detailed knowledge of the available space for implantation and pathways to access the middle and inner ears is necessary for the design of implants and successful implantation. Based on temporal bone CT scans a method for three-dimensional reconstruction of a virtual canal wall up mastoidectomy space is described. Using Amira® software the area to be removed during such surgery is marked on axial CT slices, and a three-dimensional model of that space is created. The average volume of 31 reconstructed models is 12.6 cm3 with standard deviation of 3.69 cm3, ranging from 7.97 to 23.25 cm3. Critical distances were measured directly from the model and their averages were calculated: height 3.69 cm, depth 2.43 cm, length above the external auditory canal (EAC) 4.45 cm and length posterior to EAC 3.16 cm. These linear measurements did not correlate well with volume measurements. The shape of the models was variable to a significant extent making the prediction of successful implantation for a given design based on linear and volumetric measurement unreliable. Hence, to assure successful implantation, preoperative assessment should include a virtual fitting of an implant into the intended storage space. The above-mentioned three-dimensional models were exported from Amira to a Solidworks application where virtual fitting was performed. Our results are compared to other temporal bone implant virtual fitting studies. Virtual fitting has been suggested for other human applications. PMID:19372649
A temporal bone surgery simulator with real-time feedback for surgical training.
Wijewickrema, Sudanthi; Ioannou, Ioanna; Zhou, Yun; Piromchai, Patorn; Bailey, James; Kennedy, Gregor; O'Leary, Stephen
2014-01-01
Timely feedback on surgical technique is an important aspect of surgical skill training in any learning environment, be it virtual or otherwise. Feedback on technique should be provided in real-time to allow trainees to recognize and amend their errors as they occur. Expert surgeons have typically carried out this task, but they have limited time available to spend with trainees. Virtual reality surgical simulators offer effective, repeatable training at relatively low cost, but their benefits may not be fully realized while they still require the presence of experts to provide feedback. We attempt to overcome this limitation by introducing a real-time feedback system for surgical technique within a temporal bone surgical simulator. Our evaluation study shows that this feedback system performs exceptionally well with respect to accuracy and effectiveness.
A Downloadable Three-Dimensional Virtual Model of the Visible Ear
Wang, Haobing; Merchant, Saumil N.; Sorensen, Mads S.
2008-01-01
Purpose To develop a three-dimensional (3-D) virtual model of a human temporal bone and surrounding structures. Methods A fresh-frozen human temporal bone was serially sectioned and digital images of the surface of the tissue block were recorded (the ‘Visible Ear’). The image stack was resampled at a final resolution of 50 × 50 × 50/100 µm/voxel, registered in custom software and segmented in PhotoShop® 7.0. The segmented image layers were imported into Amira® 3.1 to generate smooth polygonal surface models. Results The 3-D virtual model presents the structures of the middle, inner and outer ears in their surgically relevant surroundings. It is packaged within a cross-platform freeware, which allows for full rotation, visibility and transparency control, as well as the ability to slice the 3-D model open at any section. The appropriate raw image can be superimposed on the cleavage plane. The model can be downloaded at https://research.meei.harvard.edu/Otopathology/3dmodels/ PMID:17124433
Zhao, Yi Chen; Kennedy, Gregor; Yukawa, Kumiko; Pyman, Brian; O'Leary, Stephen
2011-03-01
A significant benefit of virtual reality (VR) simulation is the ability to provide self-direct learning for trainees. This study aims to determine whether there are any differences in performance of cadaver temporal bone dissections between novices who received traditional teaching methods and those who received unsupervised self-directed learning in a VR temporal bone simulator. Randomized blinded control trial. Royal Victorian Eye and Ear Hospital. Twenty novice trainees. After receiving an hour lecture, participants were randomized into 2 groups to receive an additional 2 hours of training via traditional teaching methods or self-directed learning using a VR simulator with automated guidance. The simulation environment presented participants with structured training tasks, which were accompanied by real-time computer-generated feedback as well as real operative videos and photos. After the training, trainees were asked to perform a cortical mastoidectomy on a cadaveric temporal bone. The dissection was videotaped and assessed by 3 otologists blinded to participants' teaching group. The overall performance scores of the simulator-based training group were significantly higher than those of the traditional training group (67% vs 29%; P < .001), with an intraclass correlation coefficient of 0.93, indicating excellent interrater reliability. Using other assessments of performance, such as injury size, the VR simulator-based training group also performed better than the traditional group. This study indicates that self-directed learning on VR simulators can be used to improve performance on cadaver dissection in novice trainees compared with traditional teaching methods alone.
Differentiating levels of surgical experience on a virtual reality temporal bone simulator.
Zhao, Yi C; Kennedy, Gregor; Hall, Richard; O'Leary, Stephen
2010-11-01
Virtual reality simulation is increasingly being incorporated into surgical training and may have a role in temporal bone surgical education. Here we test whether metrics generated by a virtual reality surgical simulation can differentiate between three levels of experience, namely novices, otolaryngology residents, and experienced qualified surgeons. Cohort study. Royal Victorian Eye and Ear Hospital. Twenty-seven participants were recruited. There were 12 experts, six residents, and nine novices. After orientation, participants were asked to perform a modified radical mastoidectomy on the simulator. Comparisons of time taken, injury to structures, and forces exerted were made between the groups to determine which specific metrics would discriminate experience levels. Experts completed the simulated task in significantly shorter time than the other two groups (experts 22 minutes, residents 36 minutes, and novices 46 minutes; P = 0.001). Novices exerted significantly higher average forces when dissecting close to vital structures compared with experts (0.24 Newton [N] vs 0.13 N, P = 0.002). Novices were also more likely to injure structures such as dura compared to experts (23 injuries vs 3 injuries, P = 0.001). Compared with residents, the experts modulated their force between initial cortex dissection and dissection close to vital structures. Using the combination of these metrics, we were able to correctly classify the participants' level of experience 90 percent of the time. This preliminary study shows that measurements of performance obtained from within a virtual reality simulator can differentiate between levels of users' experience. These results suggest that simulator training may have a role in temporal bone training beyond foundational training. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.
Mixed reality temporal bone surgical dissector: mechanical design
2014-01-01
Objective The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. Method Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. Results Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill’s passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. Conclusion These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator. PMID:25927300
Evaluation of haptic interfaces for simulation of drill vibration in virtual temporal bone surgery.
Ghasemloonia, Ahmad; Baxandall, Shalese; Zareinia, Kourosh; Lui, Justin T; Dort, Joseph C; Sutherland, Garnette R; Chan, Sonny
2016-11-01
Surgical training is evolving from an observership model towards a new paradigm that includes virtual-reality (VR) simulation. In otolaryngology, temporal bone dissection has become intimately linked with VR simulation as the complexity of anatomy demands a high level of surgeon aptitude and confidence. While an adequate 3D visualization of the surgical site is available in current simulators, the force feedback rendered during haptic interaction does not convey vibrations. This lack of vibration rendering limits the simulation fidelity of a surgical drill such as that used in temporal bone dissection. In order to develop an immersive simulation platform capable of haptic force and vibration feedback, the efficacy of hand controllers for rendering vibration in different drilling circumstances needs to be investigated. In this study, the vibration rendering ability of four different haptic hand controllers were analyzed and compared to find the best commercial haptic hand controller. A test-rig was developed to record vibrations encountered during temporal bone dissection and a software was written to render the recorded signals without adding hardware to the system. An accelerometer mounted on the end-effector of each device recorded the rendered vibration signals. The newly recorded vibration signal was compared with the input signal in both time and frequency domains by coherence and cross correlation analyses to quantitatively measure the fidelity of these devices in terms of rendering vibrotactile drilling feedback in different drilling conditions. This method can be used to assess the vibration rendering ability in VR simulation systems and selection of ideal haptic devices. Copyright © 2016 Elsevier Ltd. All rights reserved.
Temporal bone dissection simulator for training pediatric otolaryngology surgeons
NASA Astrophysics Data System (ADS)
Tabrizi, Pooneh R.; Sang, Hongqiang; Talari, Hadi F.; Preciado, Diego; Monfaredi, Reza; Reilly, Brian; Arikatla, Sreekanth; Enquobahrie, Andinet; Cleary, Kevin
2017-03-01
Cochlear implantation is the standard of care for infants born with severe hearing loss. Current guidelines approve the surgical placement of implants as early as 12 months of age. Implantation at a younger age poses a greater surgical challenge since the underdeveloped mastoid tip, along with thin calvarial bone, creates less room for surgical navigation and can result in increased surgical risk. We have been developing a temporal bone dissection simulator based on actual clinical cases for training otolaryngology fellows in this delicate procedure. The simulator system is based on pre-procedure CT (Computed Tomography) images from pediatric infant cases (<12 months old) at our hospital. The simulator includes: (1) simulation engine to provide the virtual reality of the temporal bone surgery environment, (2) a newly developed haptic interface for holding the surgical drill, (3) an Oculus Rift to provide a microscopic-like view of the temporal bone surgery, and (4) user interface to interact with the simulator through the Oculus Rift and the haptic device. To evaluate the system, we have collected 10 representative CT data sets and segmented the key structures: cochlea, round window, facial nerve, and ossicles. The simulator will present these key structures to the user and warn the user if needed by continuously calculating the distances between the tip of surgical drill and the key structures.
A virtual surgical environment for rehearsal of tympanomastoidectomy.
Chan, Sonny; Li, Peter; Lee, Dong Hoon; Salisbury, J Kenneth; Blevins, Nikolas H
2011-01-01
This article presents a virtual surgical environment whose purpose is to assist the surgeon in preparation for individual cases. The system constructs interactive anatomical models from patient-specific, multi-modal preoperative image data, and incorporates new methods for visually and haptically rendering the volumetric data. Evaluation of the system's ability to replicate temporal bone dissections for tympanomastoidectomy, using intraoperative video of the same patients as guides, showed strong correlations between virtual and intraoperative anatomy. The result is a portable and cost-effective tool that may prove highly beneficial for the purposes of surgical planning and rehearsal.
Piromchai, P; Ioannou, I; Wijewickrema, S; Kasemsiri, P; Lodge, J; Kennedy, G; O'Leary, S
2017-01-01
To investigate the importance of anatomical variation in acquiring skills in virtual reality cochlear implant surgery. Eleven otolaryngology residents participated in this study. They were randomly allocated to practice cochlear implant surgery on the same specimen or on different specimens for four weeks. They were then tested on two new specimens, one standard and one challenging. Videos of their performance were de-identified and reviewed independently, by two blinded consultant otolaryngologists, using a validated assessment scale. The scores were compared between groups. On the standard specimen, the round window preparation score was 2.7 ± 0.4 for the experimental group and 1.7 ± 0.6 for the control group (p = 0.01). On the challenging specimen, instrument handling and facial nerve preservation scores of the experimental group were 3.0 ± 0.4 and 3.5 ± 0.7 respectively, while the control group received scores of 2.1 ± 0.8 and 2.4 ± 0.9 respectively (p < 0.05). Training on temporal bones with differing anatomies is beneficial in the development of expertise.
Developing Decision-Making Skills Using Immersive VR
2013-06-14
Institution: Department of Otolaryngology Mailing Address: Level 2, Royal Victorian Eye and Ear Hospital, 32, Gisborne St, East Melbourne...reliability of this measure. We will also intend to integrate other data models into to the feedback system such as Pattern based models [8], and... Pattern -Based Real-Time Feedback for a Temporal Bone Simulator’, Proc. of the 19th ACM Symposium on Virtual Reality Software and Technology, 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J; Szczykutowicz, T; Bayouth, J
Purpose: To compare the ability of two dual-energy CT techniques, a novel split-filter single-source technique of superior temporal resolution against an established sequential-scan technique, to remove iodine contrast from images with minimal impact on CT number accuracy. Methods: A phantom containing 8 tissue substitute materials and vials of varying iodine concentrations (1.7–20.1 mg I /mL) was imaged using a Siemens Edge CT scanner. Dual-energy virtual non-contrast (VNC) images were generated using the novel split-filter technique, in which a 120kVp spectrum is filtered by tin and gold to create high- and low-energy spectra with < 1 second temporal separation between themore » acquisition of low- and high-energy data. Additionally, VNC images were generated with the sequential-scan technique (80 and 140kVp) for comparison. CT number accuracy was evaluated for all materials at 15, 25, and 35mGy CTDIvol. Results: The spectral separation was greater for the sequential-scan technique than the split-filter technique with dual-energy ratios of 2.18 and 1.26, respectively. Both techniques successfully removed iodine contrast, resulting in mean CT numbers within 60HU of 0HU (split-filter) and 40HU of 0HU (sequential-scan) for all iodine concentrations. Additionally, for iodine vials of varying diameter (2–20 mm) with the same concentration (9.9 mg I /mL), the system accurately detected iodine for all sizes investigated. Both dual-energy techniques resulted in reduced CT numbers for bone materials (by >400HU for the densest bone). Increasing the imaging dose did not improve the CT number accuracy for bone in VNC images. Conclusion: VNC images from the split-filter technique successfully removed iodine contrast. These results demonstrate a potential for improving dose calculation accuracy and reducing patient imaging dose, while achieving superior temporal resolution in comparison sequential scans. For both techniques, inaccuracies in CT numbers for bone materials necessitate consideration for radiation therapy treatment planning.« less
[Evaluation of a training system for middle ear surgery with optoelectric detection].
Strauss, G; Bahrami, N; Pössneck, A; Strauss, M; Dietz, A; Korb, W; Lüth, T; Haase, R; Moeckel, H; Grunert, R
2009-10-01
This work presents a new training concept for surgery of the temporal bone. It is based on a model of gypsum plastic with optoelectric detection of risk structures. A prototypical evaluation is given. The training models are based on high-resolution computed tomographic data of a human skull. The resulting data set was printed by a three-dimensional (3D) printer. A 3D phantom is created from gypsum powder and a bonding agent. Risks structures are the facial nerve, semicircular canal, cochlea, ossicular chain, sigmoid sinus, dura, and internal carotid artery. An electrically conductive metal (Wood's metal) and a fiber-optic cable were used as detection materials for the risk structures. For evaluating the training system, a study was done with eight inexperienced and eight experienced ear surgeons. They were asked to perform temporal bone surgery using two identical training models (group A). In group B, the same surgeons underwent surgical training with human cadavers. In the case of injuries, the number, point in time, degree (facial nerve), and injured structure were documented during the training on the model. In addition, the total time needed was noted. The training systems could be used in all cases. Evaluation of the anatomic accuracy of the models showed results that were between 49.5% and 90% agreement with the anatomic origin. Error detection was evaluated with values between 79% and 100% agreement with the perception of an experienced surgeon. The operating setting was estimated to be better than the previous"gold standard." The possibility of completely replacing the previous training method, which uses cadavers, with the examined training model was affirmed. This study shows that the examined system fulfills the conditions for a new training concept for temporal bone surgery. The system connects the preliminary work with printed and sintered models with the possibilities of microsystem engineering. In addition, the model's digital database permits a complete virtual representation of the model with appropriate further applications ("look behind the wall," virtual endoscopy).
Piromchai, Patorn; Avery, Alex; Laopaiboon, Malinee; Kennedy, Gregor; O'Leary, Stephen
2015-09-09
Virtual reality simulation uses computer-generated imagery to present a simulated training environment for learners. This review seeks to examine whether there is evidence to support the introduction of virtual reality surgical simulation into ear, nose and throat surgical training programmes. 1. To assess whether surgeons undertaking virtual reality simulation-based training achieve surgical ('patient') outcomes that are at least as good as, or better than, those achieved through conventional training methods.2. To assess whether there is evidence from either the operating theatre, or from controlled (simulation centre-based) environments, that virtual reality-based surgical training leads to surgical skills that are comparable to, or better than, those achieved through conventional training. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2015, Issue 6); PubMed; EMBASE; ERIC; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 27 July 2015. We included all randomised controlled trials and controlled trials comparing virtual reality training and any other method of training in ear, nose or throat surgery. We used the standard methodological procedures expected by The Cochrane Collaboration. We evaluated both technical and non-technical aspects of skill competency. We included nine studies involving 210 participants. Out of these, four studies (involving 61 residents) assessed technical skills in the operating theatre (primary outcomes). Five studies (comprising 149 residents and medical students) assessed technical skills in controlled environments (secondary outcomes). The majority of the trials were at high risk of bias. We assessed the GRADE quality of evidence for most outcomes across studies as 'low'. Operating theatre environment (primary outcomes) In the operating theatre, there were no studies that examined two of three primary outcomes: real world patient outcomes and acquisition of non-technical skills. The third primary outcome (technical skills in the operating theatre) was evaluated in two studies comparing virtual reality endoscopic sinus surgery training with conventional training. In one study, psychomotor skill (which relates to operative technique or the physical co-ordination associated with instrument handling) was assessed on a 10-point scale. A second study evaluated the procedural outcome of time-on-task. The virtual reality group performance was significantly better, with a better psychomotor score (mean difference (MD) 1.66, 95% CI 0.52 to 2.81; 10-point scale) and a shorter time taken to complete the operation (MD -5.50 minutes, 95% CI -9.97 to -1.03). Controlled training environments (secondary outcomes) In a controlled environment five studies evaluated the technical skills of surgical trainees (one study) and medical students (three studies). One study was excluded from the analysis. Surgical trainees: One study (80 participants) evaluated the technical performance of surgical trainees during temporal bone surgery, where the outcome was the quality of the final dissection. There was no difference in the end-product scores between virtual reality and cadaveric temporal bone training. Medical students: Two other studies (40 participants) evaluated technical skills achieved by medical students in the temporal bone laboratory. Learners' knowledge of the flow of the operative procedure (procedural score) was better after virtual reality than conventional training (SMD 1.11, 95% CI 0.44 to 1.79). There was also a significant difference in end-product score between the virtual reality and conventional training groups (SMD 2.60, 95% CI 1.71 to 3.49). One study (17 participants) revealed that medical students acquired anatomical knowledge (on a scale of 0 to 10) better during virtual reality than during conventional training (MD 4.3, 95% CI 2.05 to 6.55). No studies in a controlled training environment assessed non-technical skills. There is limited evidence to support the inclusion of virtual reality surgical simulation into surgical training programmes, on the basis that it can allow trainees to develop technical skills that are at least as good as those achieved through conventional training. Further investigations are required to determine whether virtual reality training is associated with better real world outcomes for patients and the development of non-technical skills. Virtual reality simulation may be considered as an additional learning tool for medical students.
Niu, Qiang; Chi, Xiaoyi; Leu, Ming C; Ochoa, Jorge
2008-01-01
This paper describes image processing, geometric modeling and data management techniques for the development of a virtual bone surgery system. Image segmentation is used to divide CT scan data into different segments representing various regions of the bone. A region-growing algorithm is used to extract cortical bone and trabecular bone structures systematically and efficiently. Volume modeling is then used to represent the bone geometry based on the CT scan data. Material removal simulation is achieved by continuously performing Boolean subtraction of the surgical tool model from the bone model. A quadtree-based adaptive subdivision technique is developed to handle the large set of data in order to achieve the real-time simulation and visualization required for virtual bone surgery. A Marching Cubes algorithm is used to generate polygonal faces from the volumetric data. Rendering of the generated polygons is performed with the publicly available VTK (Visualization Tool Kit) software. Implementation of the developed techniques consists of developing a virtual bone-drilling software program, which allows the user to manipulate a virtual drill to make holes with the use of a PHANToM device on a bone model derived from real CT scan data.
A Novel Temporal Bone Simulation Model Using 3D Printing Techniques.
Mowry, Sarah E; Jammal, Hachem; Myer, Charles; Solares, Clementino Arturo; Weinberger, Paul
2015-09-01
An inexpensive temporal bone model for use in a temporal bone dissection laboratory setting can be made using a commercially available, consumer-grade 3D printer. Several models for a simulated temporal bone have been described but use commercial-grade printers and materials to produce these models. The goal of this project was to produce a plastic simulated temporal bone on an inexpensive 3D printer that recreates the visual and haptic experience associated with drilling a human temporal bone. Images from a high-resolution CT of a normal temporal bone were converted into stereolithography files via commercially available software, with image conversion and print settings adjusted to achieve optimal print quality. The temporal bone model was printed using acrylonitrile butadiene styrene (ABS) plastic filament on a MakerBot 2x 3D printer. Simulated temporal bones were drilled by seven expert temporal bone surgeons, assessing the fidelity of the model as compared with a human cadaveric temporal bone. Using a four-point scale, the simulated bones were assessed for haptic experience and recreation of the temporal bone anatomy. The created model was felt to be an accurate representation of a human temporal bone. All raters felt strongly this would be a good training model for junior residents or to simulate difficult surgical anatomy. Material cost for each model was $1.92. A realistic, inexpensive, and easily reproducible temporal bone model can be created on a consumer-grade desktop 3D printer.
Comparison of temporal bone fractures in children and adults.
Kang, Ho Min; Kim, Myung Gu; Hong, Seok Min; Lee, Ho Yun; Kim, Tae Hyun; Yeo, Seung Geun
2013-05-01
Contrary to our expectation, that the clinical characteristics of temporal bone fracture would differ in children and adults, we found that the two groups were similar. Most studies of temporal bone fractures have been performed in adults. To our knowledge, no study has investigated differences in temporal bone fractures in children and adults. We therefore investigated differences in temporal bone fractures in adults and children by examining the manifestations and clinical symptoms of temporal bone fractures in pediatric patients. The demographic and clinical characteristics were assessed in 32 children and 186 adults with temporal bone fractures. All patients underwent computed tomography of the temporal bone. Causes of fracture, gender distribution, manifestations of temporal bone fracture, and clinical symptoms were similar in adults and children (p > 0.05 each). Petrous fracture, ear fullness, dizziness, and tinnitus were significantly more frequent in adults than in children (p < 0.05 each).
3D Printed Pediatric Temporal Bone: A Novel Training Model.
Longfield, Evan A; Brickman, Todd M; Jeyakumar, Anita
2015-06-01
Temporal bone dissection is a fundamental element of otologic training. Cadaveric temporal bones (CTB) are the gold standard surgical training model; however, many institutions do not have ready access to them and their cost can be significant: $300 to $500. Furthermore, pediatric cadaveric temporal bones are not readily available. Our objective is to develop a pediatric temporal bone model. Temporal bone model. Tertiary Children's Hospital. Pediatric patient model. We describe the novel use of a 3D printer for the generation of a plaster training model from a pediatric high- resolution CT temporal bone scan of a normal pediatric temporal bone. Three models were produced and were evaluated. The models utilized multiple colors (white for bone, yellow for the facial nerve) and were of high quality. Two models were drilled as a proof of concept and found to be an acceptable facsimile of the patient's anatomy, rendering all necessary surgical landmarks accurately. The only negative comments pertaining to the 3D printed temporal bone as a training model were the lack of variation in hardness between cortical and cancellous bone, noting a tactile variation from cadaveric temporal bones. Our novel pediatric 3D temporal bone training model is a viable, low-cost training option for previously inaccessible pediatric temporal bone training. Our hope is that, as 3D printers become commonplace, these models could be rapidly reproduced, allowing for trainees to print models of patients before performing surgery on the living patient.
Virtual reality simulation training of mastoidectomy - studies on novice performance.
Andersen, Steven Arild Wuyts
2016-08-01
Virtual reality (VR) simulation-based training is increasingly used in surgical technical skills training including in temporal bone surgery. The potential of VR simulation in enabling high-quality surgical training is great and VR simulation allows high-stakes and complex procedures such as mastoidectomy to be trained repeatedly, independent of patients and surgical tutors, outside traditional learning environments such as the OR or the temporal bone lab, and with fewer of the constraints of traditional training. This thesis aims to increase the evidence-base of VR simulation training of mastoidectomy and, by studying the final-product performances of novices, investigates the transfer of skills to the current gold-standard training modality of cadaveric dissection, the effect of different practice conditions and simulator-integrated tutoring on performance and retention of skills, and the role of directed, self-regulated learning. Technical skills in mastoidectomy were transferable from the VR simulation environment to cadaveric dissection with significant improvement in performance after directed, self-regulated training in the VR temporal bone simulator. Distributed practice led to a better learning outcome and more consolidated skills than massed practice and also resulted in a more consistent performance after three months of non-practice. Simulator-integrated tutoring accelerated the initial learning curve but also caused over-reliance on tutoring, which resulted in a drop in performance when the simulator-integrated tutor-function was discontinued. The learning curves were highly individual but often plateaued early and at an inadequate level, which related to issues concerning both the procedure and the VR simulator, over-reliance on the tutor function and poor self-assessment skills. Future simulator-integrated automated assessment could potentially resolve some of these issues and provide trainees with both feedback during the procedure and immediate assessment following each procedure. Standard setting by establishing a proficiency level that can be used for mastery learning with deliberate practice could also further sophisticate directed, self-regulated learning in VR simulation-based training. VR simulation-based training should be embedded in a systematic and competency-based training curriculum for high-quality surgical skills training, ultimately leading to improved safety and patient care.
Pearson, Alannah; Groves, Colin; Cardini, Andrea
2015-11-01
In 2004, an analysis by Lockwood and colleagues of hard-tissue morphology, using geometric morphometrics on the temporal bone, succeeded in recovering the correct phylogeny of living hominids without resorting to potentially problematic methods for transforming continuous shape variables into meristic characters. That work has increased hope that by using modern analytical methods and phylogenetically informative anatomical data we might one day be able to accurately infer the relationships of hominins, including the closest extinct relatives of modern humans. In the present study, using 3D virtually generated models of the hominid temporal bone and a larger suite of geometric morphometric and comparative techniques, we have re-examined the evidence for a Pan-Homo clade. Despite differences in samples, as well as the type of raw data, the effect of measurement error (and especially landmark digitization by a different operator), but also a broader perspective brought in by our diverse set of approaches, our reanalysis largely supports Lockwood and colleagues' original results. However, by focusing not only mainly on shape (as in the original 2004 analysis) but also on size and 'size-corrected' (non-allometric) shape, we demonstrate that the strong phylogenetic signal in the temporal bone is largely related to similarities in size. Thus, with this study, we are not suggesting the use of a single 'character', such as size, for phylogenetic inference, but we do challenge the common view that shape, with its highly complex and multivariate nature, is necessarily more phylogenetically informative than size and that actually size and size-related shape variation (i.e., allometry) confound phylogenetic inference based on morphology. This perspective may in fact be less generalizable than often believed. Thus, while we confirm the original findings by Lockwood et al., we provide a deep reinterpretation of their nature and potential implications for hominid phylogenetics and we show how crucial it is not to overlook size in geometric morphometric analyses. Copyright © 2015 Elsevier Ltd. All rights reserved.
Terhune, Claire E; Kimbel, William H; Lockwood, Charles A
2013-08-01
Assessments of temporal bone morphology have played an important role in taxonomic and phylogenetic evaluations of fossil taxa, and recent three-dimensional analyses of this region have supported the utility of the temporal bone for testing taxonomic and phylogenetic hypotheses. But while clinical analyses have examined aspects of temporal bone ontogeny in humans, the ontogeny of the temporal bone in non-human taxa is less well documented. This study examines ontogenetic allometry of the temporal bone in order to address several research questions related to the pattern and trajectory of temporal bone shape change during ontogeny in the African apes and humans. We further apply these data to a preliminary analysis of temporal bone ontogeny in Australopithecus afarensis. Three-dimensional landmarks were digitized on an ontogenetic series of specimens of Homo sapiens, Pan troglodytes, Pan paniscus, and Gorilla gorilla. Data were analyzed using geometric morphometric methods, and shape changes throughout ontogeny in relation to size were compared. Results of these analyses indicate that, despite broadly similar patterns, African apes and humans show marked differences in development of the mandibular fossa and tympanic portions of the temporal bone. These findings indicate divergent, rather than parallel, postnatal ontogenetic allometric trajectories for temporal bone shape in these taxa. The pattern of temporal bone shape change with size exhibited by A. afarensis showed some affinities to that of humans, but was most similar to extant African apes, particularly Gorilla. Copyright © 2013 Wiley Periodicals, Inc.
Multi-material 3D Models for Temporal Bone Surgical Simulation.
Rose, Austin S; Kimbell, Julia S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Buchman, Craig A
2015-07-01
A simulated, multicolor, multi-material temporal bone model can be created using 3-dimensional (3D) printing that will prove both safe and beneficial in training for actual temporal bone surgical cases. As the process of additive manufacturing, or 3D printing, has become more practical and affordable, a number of applications for the technology in the field of Otolaryngology-Head and Neck Surgery have been considered. One area of promise is temporal bone surgical simulation. Three-dimensional representations of human temporal bones were created from temporal bone computed tomography (CT) scans using biomedical image processing software. Multi-material models were then printed and dissected in a temporal bone laboratory by attending and resident otolaryngologists. A 5-point Likert scale was used to grade the models for their anatomical accuracy and suitability as a simulation of cadaveric and operative temporal bone drilling. The models produced for this study demonstrate significant anatomic detail and a likeness to human cadaver specimens for drilling and dissection. Simulated temporal bones created by this process have potential benefit in surgical training, preoperative simulation for challenging otologic cases, and the standardized testing of temporal bone surgical skills. © The Author(s) 2015.
Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D
2017-09-01
Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.
Da Cruz, M J; Francis, H W
2015-07-01
To assess the face and content validity of a novel synthetic, three-dimensional printed temporal bone for surgical skills development and training. A synthetic temporal bone was printed using composite materials and three-dimensional printing technology. Surgical trainees were asked to complete three structured temporal bone dissection exercises. Attitudes and impressions were then assessed using a semi-structured questionnaire. Previous cadaver and real operating experiences were used as a reference. Trainees' experiences of the synthetic temporal bone were analysed in terms of four domains: anatomical realism, usefulness as a training tool, task-based usefulness and overall reactions. Responses across all domains indicated a high degree of acceptance, suggesting that the three-dimensional printed temporal bone was a useful tool in skills development. A sophisticated three-dimensional printed temporal bone that demonstrates face and content validity was developed. The efficiency in cost savings coupled with low associated biohazards make it likely that the printed temporal bone will be incorporated into traditional temporal bone skills development programmes in the near future.
Primary pericranial Ewing's sarcoma on the temporal bone: A case report.
Kawano, Hiroto; Nitta, Naoki; Ishida, Mitsuaki; Fukami, Tadateru; Nozaki, Kazuhiko
2016-01-01
Primary Ewing's sarcoma originating in the pericranium is an extremely rare disease entity. A 9-year-old female patient was admitted to our department due to a left temporal subcutaneous mass. The mass was localized under the left temporal muscle and attached to the surface of the temporal bone. Head computed tomography revealed a mass with bony spicule formation on the temporal bone, however, it did not show bone destruction or intracranial invasion. F-18 fluorodeoxyglucose positron emission tomography showed no lesions other than the mass on the temporal bone. Magnetic resonance imaging showed that the mass was located between the temporal bone and the pericranium. The mass was completely resected with the underlying temporal bone and the overlying deep layer of temporal muscle, and was diagnosed as primary Ewing's sarcoma. Because the tumor was located in the subpericranium, we created a new classification, "pericranial Ewing's sarcoma," and diagnosed the present tumor as pericranial Ewing's sarcoma. We herein present an extremely rare case of primary pericranial Ewing's sarcoma that developed on the temporal bone.
[Computed tomography of the temporal bone in diagnosis of chronic exudative otitis media].
Zelikovich, E I
2005-01-01
Computed tomography (CT) of the temporal bone was made in 37 patients aged 2 to 55 years with chronic exudative otitis media (CEOM). In 21 of them the pathology was bilateral. The analysis of 58 CT images has identified CT signs of chronic exudative otitis media. They include partial (17 temporary bones) or complete (38 temporal bones) block of the bone opening of the auditory tube, pneumatic defects of the tympanic cavity (58 temporal bones), pneumatic defects of the mastoid process and antrum (47 temporal bones), pathologic retraction of the tympanic membrane. The examination of the temporal bone detected both CT-signs of CEOM and other causes of hearing disorders in 14 patients (26 temporal bones) with CEOM symptoms and inadequately high hypoacusis. Among these causes were malformation of the auditory ossicula (n=5), malformation of the labynthine window (n=2), malformation of the middle and internal ear (n=4), a wide aqueduct of the vestibule, labyrinthine anomaly of Mondini's type (n=1), cochlear hypoplasia (n=4), stenosis of the internal acoustic meatuses (n=2). Sclerotic fibrous dysplasia was suggested in 2 temporal bones (by CT data). CT was repeated after surgical treatment of 10 patients (14 temporal bones) and visual assessment of tympanostomy results was made.
A Bone-Thickness Map as a Guide for Bone-Anchored Port Implantation Surgery in the Temporal Bone
Guignard, Jérémie; Arnold, Andreas; Weisstanner, Christian; Caversaccio, Marco; Stieger, Christof
2013-01-01
The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant’s location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map (n = 10) with conventional surgery without assistance (n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient’s safety during BAP surgery in the temporal bone. PMID:28788390
A Bone-Thickness Map as a Guide for Bone-Anchored Port Implantation Surgery in the Temporal Bone.
Guignard, Jérémie; Arnold, Andreas; Weisstanner, Christian; Caversaccio, Marco; Stieger, Christof
2013-11-19
The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant's location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map ( n = 10) with conventional surgery without assistance ( n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient's safety during BAP surgery in the temporal bone.
Geometric modeling of the temporal bone for cochlea implant simulation
NASA Astrophysics Data System (ADS)
Todd, Catherine A.; Naghdy, Fazel; O'Leary, Stephen
2004-05-01
The first stage in the development of a clinically valid surgical simulator for training otologic surgeons in performing cochlea implantation is presented. For this purpose, a geometric model of the temporal bone has been derived from a cadaver specimen using the biomedical image processing software package Analyze (AnalyzeDirect, Inc) and its three-dimensional reconstruction is examined. Simulator construction begins with registration and processing of a Computer Tomography (CT) medical image sequence. Important anatomical structures of the middle and inner ear are identified and segmented from each scan in a semi-automated threshold-based approach. Linear interpolation between image slices produces a three-dimensional volume dataset: the geometrical model. Artefacts are effectively eliminated using a semi-automatic seeded region-growing algorithm and unnecessary bony structures are removed. Once validated by an Ear, Nose and Throat (ENT) specialist, the model may be imported into the Reachin Application Programming Interface (API) (Reachin Technologies AB) for visual and haptic rendering associated with a virtual mastoidectomy. Interaction with the model is realized with haptics interfacing, providing the user with accurate torque and force feedback. Electrode array insertion into the cochlea will be introduced in the final stage of design.
Ogura, I; Kaneda, T; Sasaki, Y; Buch, K; Sakai, O
2015-06-01
Temporal bone fracture after mandibular trauma is thought to be rare, and its prevalence has not been reported in the literature. The purpose of this study was to investigate the prevalence of temporal bone fractures in patients with mandibular fractures and the relationship between temporal bone fractures and the mandibular fracture location using multidetector-row computed tomography (MDCT). A prospective study was performed in 201 patients with mandibular fractures who underwent 64-MDCT scans. The mandibular fracture locations were classified as median, paramedian, angle, and condylar types. Statistical analysis for the relationship between prevalence of temporal bone fractures and mandibular fracture locations was performed using χ(2) test with Fisher's exact test. A P-value < 0.05 was considered statistically significant. The percentage of cases with temporal bone fracture was 3.0 % of all patients with mandibular fractures and 19.0 % of those with multiple mandibular fractures of paramedian and condylar type. There was a significant relationship between the incidence of temporal bone fracture and the paramedian- and condylar-type mandibular fracture (P = 0.001). Multiple mandibular fractures of paramedian and condylar type may be a stronger indicator for temporal bone fractures. This study suggests that patients with mandibular fracture, especially the paramedian and condylar type, should be examined for coexisting temporal bone fracture using MDCT.
Chapman, Tara; Lefevre, Philippe; Semal, Patrick; Moiseev, Fedor; Sholukha, Victor; Louryan, Stéphane; Rooze, Marcel; Van Sint Jan, Serge
2014-01-01
The hip bone is one of the most reliable indicators of sex in the human body due to the fact it is the most dimorphic bone. Probabilistic Sex Diagnosis (DSP: Diagnose Sexuelle Probabiliste) developed by Murail et al., in 2005, is a sex determination method based on a worldwide hip bone metrical database. Sex is determined by comparing specific measurements taken from each specimen using sliding callipers and computing the probability of specimens being female or male. In forensic science it is sometimes not possible to sex a body due to corpse decay or injury. Skeletalization and dissection of a body is a laborious process and desecrates the body. There were two aims to this study. The first aim was to examine the accuracy of the DSP method in comparison with a current visual sexing method on sex determination. A further aim was to see if it was possible to virtually utilise the DSP method on both the hip bone and the pelvic girdle in order to utilise this method for forensic sciences. For the first part of the study, forty-nine dry hip bones of unknown sex were obtained from the Body Donation Programme of the Université Libre de Bruxelles (ULB). A comparison was made between DSP analysis and visual sexing on dry bone by two researchers. CT scans of bones were then analysed to obtain three-dimensional (3D) virtual models and the method of DSP was analysed virtually by importing the models into a customised software programme called lhpFusionBox which was developed at ULB. The software enables DSP distances to be measured via virtually-palpated bony landmarks. There was found to be 100% agreement of sex between the manual and virtual DSP method. The second part of the study aimed to further validate the method by analysing thirty-nine supplementary pelvic girdles of known sex blind. There was found to be a 100% accuracy rate further demonstrating that the virtual DSP method is robust. Statistically significant differences were found in the identification of sex between researchers in the visual sexing method although both researchers identified the same sex in all cases in the manual and virtual DSP methods for both the hip bones and pelvic girdles. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Role of mastoid pneumatization in temporal bone fractures.
Ilea, A; Butnaru, A; Sfrângeu, S A; Hedeşiu, M; Dudescu, C M; Berce, P; Chezan, H; Hurubeanu, L; Trombiţaş, V E; Câmpian, R S; Albu, S
2014-07-01
The mastoid portion of the temporal bone has multiple functional roles in the organism, including regulation of pressure in the middle ear and protection of the inner ear. We investigated whether mastoid pneumatization plays a role in the protection of vital structures in the temporal bone during direct lateral trauma. The study was performed on 20 human temporal bones isolated from cadavers. In the study group formed by 10 temporal bone samples, mastoid cells were removed and the resulting neocavities were filled. The mastoids were maintained intact in the control group. All samples were impacted at the same speed and kinetic energy. The resultant temporal bone fractures were evaluated by CT. Temporal squama fractures were 2.88 times more frequent, and mastoid fractures were 2.76 times more frequent in the study group. Facial nerve canal fractures were 6 times more frequent in the study group and involved all the segments of the facial nerve. Carotid canal fractures and jugular foramen fractures were 2.33 and 2.5 times, respectively, more frequent in the study group. The mastoid portion of the temporal bone plays a role in the absorption and dispersion of kinetic energy during direct lateral trauma to the temporal bone, reducing the incidence of fracture in the setting of direct trauma. © 2014 by American Journal of Neuroradiology.
Novotny, Vojtech; Nacu, Aliona; Kvistad, Christopher E; Fromm, Annette; Neckelmann, Gesche F; Khanevski, Andrej N; Tobro, Haakon; Waje-Andreassen, Ulrike; Naess, Halvor; Thomassen, Lars; Logallo, Nicola
2017-11-08
Contrast-enhanced sonothrombolysis (CEST) seems to be a safe and promising treatment in acute ischemic stroke. It remains unknown if temporal bone features may influence the efficacy of CEST. We investigated the association between different temporal bone features on admission computed tomography (CT) scan and the outcome in acute ischemic stroke patients included in the randomized Norwegian Sonothrombolysis in Acute Stroke Study (NOR-SASS). Patients diagnosed as stroke mimics and those with infratentorial stroke or with incorrect insonation were excluded. We retrospectively assessed temporal bone heterogeneity (presence of diploë), diploë ratio, thickness, and density on admission CT scans. National institute of Health Stroke Scale (NIHSS) at 24 h and modified Rankin Scale (mRS) at 3 months were correlated with CT findings both in CEST and sham CEST patients. A total of 99 patients were included of which 52 were assigned to CEST and 47 to sham CEST. Approximately 20% patients had a heterogeneous temporal bone in both the CEST and sham CEST group. All temporal bone CT features studied were associated with female sex. In the CEST group, temporal bone heterogeneity (p = 0.006) and higher temporal bone diploë ratio (p = 0.002) were associated with higher NIHSS at 24 h. There was no association between temporal bone features and mRS at 3 months. Approximately 20% of acute ischemic stroke patients have heterogeneous temporal bone and may be resistant to standard 2-MHz transcranial Doppler ultrasound treatment. Sonothrombolysis resistance may easily be predicted by admission CT for better selection.
Otosclerosis: Temporal Bone Pathology.
Quesnel, Alicia M; Ishai, Reuven; McKenna, Michael J
2018-04-01
Otosclerosis is pathologically characterized by abnormal bony remodeling, which includes bone resorption, new bone deposition, and vascular proliferation in the temporal bone. Sensorineural hearing loss in otosclerosis is associated with extension of otosclerosis to the cochlear endosteum and deposition of collagen throughout the spiral ligament. Persistent or recurrent conductive hearing loss after stapedectomy has been associated with incomplete footplate fenestration, poor incus-prosthesis connection, and incus resorption in temporal bone specimens. Human temporal bone pathology has helped to define the role of computed tomography imaging for otosclerosis, confirming that computed tomography is highly sensitive for diagnosis, yet limited in assessing cochlear endosteal involvement. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Irwansyah; Sinh, N. P.; Lai, J. Y.; Essomba, T.; Asbar, R.; Lee, P. Y.
2018-02-01
In this paper, we present study to integrate virtual fracture bone reduction simulation tool with a novel hybrid 3-DOF-RPS external fixator to relocate back bone fragments into their anatomically original position. A 3D model of fractured bone was reconstructed and manipulated using 3D design and modeling software, PhysiGuide. The virtual reduction system was applied to reduce a bilateral femoral shaft fracture type 32-A3. Measurement data from fracture reduction and fixation stages were implemented to manipulate the manipulator pose in patient’s clinical case. The experimental result presents that by merging both of those techniques will give more possibilities to reduce virtual bone reduction time, improve facial and shortest healing treatment.
Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.
Balzeau, Antoine; Grimaud-Hervé, Dominique
2006-10-01
The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.
Cochlear Implantation after Bilateral Transverse Temporal Bone Fractures
Shin, Jong-Heon; Park, SooChan; Baek, Sam-Hyun
2008-01-01
Patients deafened by a severe head injury are rarely encountered. We report a case of a 65-yr-old man with bilateral transverse temporal bone fractures due to head injury. He underwent cochlear implant and achieved a satisfactory auditory rehabilitation. Imaging studies of temporal bone before performing a cochlear implantation provide important information on a patient with bilateral temporal bone fractures. Cochlear implantations with careful planning in such a patient may be a very effective method for aural rehabilitation. PMID:19434252
Content Validity of Temporal Bone Models Printed Via Inexpensive Methods and Materials.
Bone, T Michael; Mowry, Sarah E
2016-09-01
Computed tomographic (CT) scans of the 3-D printed temporal bone models will be within 15% accuracy of the CT scans of the cadaveric temporal bones. Previous studies have evaluated the face validity of 3-D-printed temporal bone models designed to train otolaryngology residents. The purpose of the study was to determine the content validity of temporal bone models printed using inexpensive printers and materials. Four cadaveric temporal bones were randomly selected and clinical temporal bone CT scans were obtained. Models were generated using previously described methods in acrylonitrile butadiene styrene (ABS) plastic using the Makerbot Replicator 2× and Hyrel printers. Models were radiographically scanned using the same protocol as the cadaveric bones. Four images from each cadaveric CT series and four corresponding images from the model CT series were selected, and voxel values were normalized to black or white. Scan slices were compared using PixelDiff software. Gross anatomic structures were evaluated in the model scans by four board certified otolaryngologists on a 4-point scale. Mean pixel difference between the cadaver and model scans was 14.25 ± 2.30% at the four selected CT slices. Mean cortical bone width difference and mean external auditory canal width difference were 0.58 ± 0.66 mm and 0.55 ± 0.46 mm, respectively. Expert raters felt the mastoid air cells were well represented (2.5 ± 0.5), while middle ear and otic capsule structures were not accurately rendered (all averaged <1.8). These results suggest that these models would be sufficient adjuncts to cadaver temporal bones for training residents in cortical mastoidectomies, but less effective for middle ear procedures.
Matsushima, Ken; Komune, Noritaka; Matsuo, Satoshi; Kohno, Michihiro
2017-07-01
The use of the retrosigmoid approach has recently been expanded by several modifications, including the suprameatal, transmeatal, suprajugular, and inframeatal extensions. Intradural temporal bone drilling without damaging vital structures inside or beside the bone, such as the internal carotid artery and jugular bulb, is a key step for these extensions. This study aimed to examine the microsurgical and endoscopic anatomy of the extensions of the retrosigmoid approach and to evaluate the clinical feasibility of an electromagnetic navigation system during intradural temporal bone drilling. Five temporal bones and 8 cadaveric cerebellopontine angles were examined to clarify the anatomy of retrosigmoid intradural temporal bone drilling. Twenty additional cerebellopontine angles were dissected in a clinical setting with an electromagnetic navigation system while measuring the target registration errors at 8 surgical landmarks on and inside the temporal bone. Retrosigmoid intradural temporal bone drilling expanded the surgical exposure to allow access to the petroclival and parasellar regions (suprameatal), internal acoustic meatus (transmeatal), upper jugular foramen (suprajugular), and petrous apex (inframeatal). The electromagnetic navigation continuously guided the drilling without line of sight limitation, and its small devices were easily manipulated in the deep and narrow surgical field in the posterior fossa. Mean target registration error was less than 0.50 mm during these procedures. The combination of endoscopic and microsurgical techniques aids in achieving optimal exposure for retrosigmoid intradural temporal bone drilling. The electromagnetic navigation system had clear advantages with acceptable accuracy including the usability of small devices without line of sight limitation. Copyright © 2017 Elsevier Inc. All rights reserved.
The role of virtual reality in surgical training in otorhinolaryngology.
Fried, Marvin P; Uribe, José I; Sadoughi, Babak
2007-06-01
This article reviews the rationale, current status and future directions for the development and implementation of virtual reality surgical simulators as training tools. The complexity of modern surgical techniques, which utilize advanced technology, presents a dilemma for surgical training. Hands-on patient experience - the traditional apprenticeship method for teaching operations - may not apply because of the learning curve for skill acquisition and patient safety expectation. The paranasal sinuses and temporal bone have intricate anatomy with a significant amount of vital structures either within the surgical field or in close proximity. The current standard of surgical care in these areas involves the use of endoscopes, cameras and microscopes, requiring additional hand-eye coordination, an accurate command of fine motor skills, and a thorough knowledge of the anatomy under magnified vision. A surgeon's disorientation or loss of perspective can lead to complications, often catastrophic and occasionally lethal. These considerations define the ideal environment for surgical simulation; not surprisingly, significant research and validation of simulators in these areas have occurred. Virtual reality simulators are demonstrating validity as training and skills assessment tools. Future prototypes will find application for routine use in teaching, surgical planning and the development of new instruments and computer-assisted devices.
Correlations of External Landmarks With Internal Structures of the Temporal Bone.
Piromchai, Patorn; Wijewickrema, Sudanthi; Smeds, Henrik; Kennedy, Gregor; O'Leary, Stephen
2015-09-01
The internal anatomy of a temporal bone could be inferred from external landmarks. Mastoid surgery is an important skill that ENT surgeons need to acquire. Surgeons commonly use CT scans as a guide to understanding anatomical variations before surgery. Conversely, in cases where CT scans are not available, or in the temporal bone laboratory where residents are usually not provided with CT scans, it would be beneficial if the internal anatomy of a temporal bone could be inferred from external landmarks. We explored correlations between internal anatomical variations and metrics established to quantify the position of external landmarks that are commonly exposed in the operating room, or the temporal bone laboratory, before commencement of drilling. Mathematical models were developed to predict internal anatomy based on external structures. From an operating room view, the distances between the following external landmarks were observed to have statistically significant correlations with the internal anatomy of a temporal bone: temporal line, external auditory canal, mastoid tip, occipitomastoid suture, and Henle's spine. These structures can be used to infer a low lying dura mater (p = 0.002), an anteriorly located sigmoid sinus (p = 0.006), and a more lateral course of the facial nerve (p < 0.001). In the temporal bone laboratory view, the mastoid tegmen and sigmoid sinus were also regarded as external landmarks. The distances between these two landmarks and the operating view external structures were able to further infer the laterality of the facial nerve (p < 0.001) and a sclerotic mastoid (p < 0.001). Two nonlinear models were developed that predicted the distances between the following internal structures with a high level of accuracy: the distance from the sigmoid sinus to the posterior external auditory canal (p < 0.001) and the diameter of the round window niche (p < 0.001). The prospect of encountering some of the more technically challenging anatomical variants encountered in temporal bone dissection can be inferred from the distance between external landmarks found on the temporal bone. These relationships could be used as a guideline to predict challenges during drilling and choosing appropriate temporal bones for dissection.
Experimental and numeric stress analysis of titanium and zirconia one-piece dental implants.
Mobilio, Nicola; Stefanoni, Filippo; Contiero, Paolo; Mollica, Francesco; Catapano, Santo
2013-01-01
To compare the stress in bone around zirconia and titanium implants under loading. A one-piece zirconia implant and a replica of the same implant made of commercially pure titanium were embedded in two self-curing acrylic resin blocks. To measure strain, a strain gauge was applied on the surface of the two samples. Loads of 50, 100, and 150 N, with orientations of 30, 45, and 60 degrees with respect to the implant axis were applied on the implant. Strain under all loading conditions on both samples was measured. Three-dimensional virtual replicas of both the implants were reproduced using the finite element method and inserted into a virtual acrylic resin block. All the materials were considered isotropic, linear, and elastic. The same geometry and loading conditions of the experimental setup were used to realize two new models, with the implants embedded within a virtual bone block. Very close values of strain in the two implants embedded in acrylic resin were obtained both experimentally and numerically. The stress states generated by the implants embedded in virtual bone were also very similar, even if the two implants moved differently. Moreover, the stress levels were higher on cortical bone than on trabecular bone. The stress levels in bone, generated by the two implants, appeared to be very similar. From a mechanical point of view, zirconia is a feasible substitute for titanium.
Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models.
Rose, Austin S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Rawal, Rounak B; Iseli, Claire E
2015-05-01
As the process of additive manufacturing, or three-dimensional (3D) printing, has become more practical and affordable, a number of applications for the technology in the field of pediatric otolaryngology have been considered. One area of promise is temporal bone surgical simulation. Having previously developed a model for temporal bone surgical training using 3D printing, we sought to produce a patient-specific model for pre-operative simulation in pediatric otologic surgery. Our hypothesis was that the creation and pre-operative dissection of such a model was possible, and would demonstrate potential benefits in cases of abnormal temporal bone anatomy. In the case presented, an 11-year-old boy underwent a planned canal-wall-down (CWD) tympano-mastoidectomy for recurrent cholesteatoma preceded by a pre-operative surgical simulation using 3D-printed models of the temporal bone. The models were based on the child's pre-operative clinical CT scan and printed using multiple materials to simulate both bone and soft tissue structures. To help confirm the models as accurate representations of the child's anatomy, distances between various anatomic landmarks were measured and compared to the temporal bone CT scan and the 3D model. The simulation allowed the surgical team to appreciate the child's unusual temporal bone anatomy as well as any challenges that might arise in the safety of the temporal bone laboratory, prior to actual surgery in the operating room (OR). There was minimal variability, in terms of absolute distance (mm) and relative distance (%), in measurements between anatomic landmarks obtained from the patient intra-operatively, the pre-operative CT scan and the 3D-printed models. Accurate 3D temporal bone models can be rapidly produced based on clinical CT scans for pre-operative simulation of specific challenging otologic cases in children, potentially reducing medical errors and improving patient safety. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Fujiyoshi, T; Mogi, G; Watanabe, T; Matsushita, F
1992-01-01
Using a novel method of cutting undecalcified temporal bone specimens, quantitative structural analysis in the human and the Japanese monkey was undertaken. One millimeter thick serial slices made from unembedded temporal bones retained fine structure. Therefore, gross to fine observation could be performed systematically at the macroscopic, light, scanning, and transmission electron microscopic levels. The entire temporal bone three-dimensional reconstruction was completed from embedded sections; consequently, the volume of the tubotympanum and air cell system could be calculated. Available methods by embedding, tungsten carbide sectioning, grinding, and microwave irradiation for decalcification were also examined. These morphologic studies suggest that these novel methods offer timesaving advantages over any presently available techniques, and allow for elucidation of temporal bone morphology with only a few specimens.
Temporal Issues in the Design of Virtual Learning Environments.
ERIC Educational Resources Information Center
Bergeron, Bryan; Obeid, Jihad
1995-01-01
Describes design methods used to influence user perception of time in virtual learning environments. Examines the use of temporal cues in medical education and clinical competence testing. Finds that user perceptions of time affects user acceptance, ease of use, and the level of realism of a virtual learning environment. Contains 51 references.…
Dérand, Per; Rännar, Lars-Erik; Hirsch, Jan-M
2012-01-01
The purpose of this article was to describe the workflow from imaging, via virtual design, to manufacturing of patient-specific titanium reconstruction plates, cutting guide and mesh, and its utility in connection with surgical treatment of acquired bone defects in the mandible using additive manufacturing by electron beam melting (EBM). Based on computed tomography scans, polygon skulls were created. Following that virtual treatment plans entailing free microvascular transfer of fibula flaps using patient-specific reconstruction plates, mesh, and cutting guides were designed. The design was based on the specification of a Compact UniLOCK 2.4 Large (Synthes®, Switzerland). The obtained polygon plates were bent virtually round the reconstructed mandibles. Next, the resections of the mandibles were planned virtually. A cutting guide was outlined to facilitate resection, as well as plates and titanium mesh for insertion of bone or bone substitutes. Polygon plates and meshes were converted to stereolithography format and used in the software Magics for preparation of input files for the successive step, additive manufacturing. EBM was used to manufacture the customized implants in a biocompatible titanium grade, Ti6Al4V ELI. The implants and the cutting guide were cleaned and sterilized, then transferred to the operating theater, and applied during surgery. Commercially available software programs are sufficient in order to virtually plan for production of patient-specific implants. Furthermore, EBM-produced implants are fully usable under clinical conditions in reconstruction of acquired defects in the mandible. A good compliance between the treatment plan and the fit was demonstrated during operation. Within the constraints of this article, the authors describe a workflow for production of patient-specific implants, using EBM manufacturing. Titanium cutting guides, reconstruction plates for fixation of microvascular transfer of osteomyocutaneous bone grafts, and mesh to replace resected bone that can function as a carrier for bone or bone substitutes were designed and tested during reconstructive maxillofacial surgery. A clinically fit, well within the requirements for what is needed and obtained using traditional free hand bending of commercially available devices, or even higher precision, was demonstrated in ablative surgery in four patients. PMID:23997858
Dérand, Per; Rännar, Lars-Erik; Hirsch, Jan-M
2012-09-01
The purpose of this article was to describe the workflow from imaging, via virtual design, to manufacturing of patient-specific titanium reconstruction plates, cutting guide and mesh, and its utility in connection with surgical treatment of acquired bone defects in the mandible using additive manufacturing by electron beam melting (EBM). Based on computed tomography scans, polygon skulls were created. Following that virtual treatment plans entailing free microvascular transfer of fibula flaps using patient-specific reconstruction plates, mesh, and cutting guides were designed. The design was based on the specification of a Compact UniLOCK 2.4 Large (Synthes(®), Switzerland). The obtained polygon plates were bent virtually round the reconstructed mandibles. Next, the resections of the mandibles were planned virtually. A cutting guide was outlined to facilitate resection, as well as plates and titanium mesh for insertion of bone or bone substitutes. Polygon plates and meshes were converted to stereolithography format and used in the software Magics for preparation of input files for the successive step, additive manufacturing. EBM was used to manufacture the customized implants in a biocompatible titanium grade, Ti6Al4V ELI. The implants and the cutting guide were cleaned and sterilized, then transferred to the operating theater, and applied during surgery. Commercially available software programs are sufficient in order to virtually plan for production of patient-specific implants. Furthermore, EBM-produced implants are fully usable under clinical conditions in reconstruction of acquired defects in the mandible. A good compliance between the treatment plan and the fit was demonstrated during operation. Within the constraints of this article, the authors describe a workflow for production of patient-specific implants, using EBM manufacturing. Titanium cutting guides, reconstruction plates for fixation of microvascular transfer of osteomyocutaneous bone grafts, and mesh to replace resected bone that can function as a carrier for bone or bone substitutes were designed and tested during reconstructive maxillofacial surgery. A clinically fit, well within the requirements for what is needed and obtained using traditional free hand bending of commercially available devices, or even higher precision, was demonstrated in ablative surgery in four patients.
Tympanic plate fractures in temporal bone trauma: prevalence and associated injuries.
Wood, C P; Hunt, C H; Bergen, D C; Carlson, M L; Diehn, F E; Schwartz, K M; McKenzie, G A; Morreale, R F; Lane, J I
2014-01-01
The prevalence of tympanic plate fractures, which are associated with an increased risk of external auditory canal stenosis following temporal bone trauma, is unknown. A review of posttraumatic high-resolution CT temporal bone examinations was performed to determine the prevalence of tympanic plate fractures and to identify any associated temporal bone injuries. A retrospective review was performed to evaluate patients with head trauma who underwent emergent high-resolution CT examinations of the temporal bone from July 2006 to March 2012. Fractures were identified and assessed for orientation; involvement of the tympanic plate, scutum, bony labyrinth, facial nerve canal, and temporomandibular joint; and ossicular chain disruption. Thirty-nine patients (41.3 ± 17.2 years of age) had a total of 46 temporal bone fractures (7 bilateral). Tympanic plate fractures were identified in 27 (58.7%) of these 46 fractures. Ossicular disruption occurred in 17 (37.0%). Fractures involving the scutum occurred in 25 (54.4%). None of the 46 fractured temporal bones had a mandibular condyle dislocation or fracture. Of the 27 cases of tympanic plate fractures, 14 (51.8%) had ossicular disruption (P = .016) and 18 (66.6%) had a fracture of the scutum (P = .044). Temporomandibular joint gas was seen in 15 (33%) but was not statistically associated with tympanic plate fracture (P = .21). Tympanic plate fractures are commonly seen on high-resolution CT performed for evaluation of temporal bone trauma. It is important to recognize these fractures to avoid the preventable complication of external auditory canal stenosis and the potential for conductive hearing loss due to a fracture involving the scutum or ossicular chain.
Hirakuri, Ayaka; Numasawa, Kanako; Takeishi, Hideki; Satomura, Minato; Takeda, Hiromitsu; Harada, Kuniaki; Asanuma, Osamu; Sakata, Motomichi
2012-01-01
The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone.
Hematogenous Renal Cell Carcinoma Metastasis in the Postoperative Temporal Bone
Konishi, Masaya; Suzuki, Kensuke; Iwai, Hiroshi
2017-01-01
Metastatic renal cell carcinoma (RCC) involving the temporal bone is a rare entity. It is usually asymptomatic and misdiagnosis as acute otitis media, mastoiditis, and Ramsay-Hunt syndrome in early onset is not uncommon. We report a case of RCC metastasis to the postoperative temporal bone in the middle of molecular targeted therapy. A 60-year-old man presented left facial palsy with severe retro-auricular pain and he also underwent left middle ear surgery for cholesteatoma more than 30 years before and had been aware of discontinuous otorrhea; therefore, initially we speculated that facial palsy was derived from recurrent cholesteatoma or Ramsay-Hunt syndrome. Exploratory tympanotomy revealed RCC metastasis and postoperative MR indicated hematogenous metastasis. To the best of our knowledge, no report was obtained on temporal bone metastasis in the middle of chemotherapy or hematogenous metastasis in the postoperative middle ear. Metastasis in the temporal bone is still a possible pathological condition despite the development of present cancer therapy. Besides, this case indicates that hematogenous metastasis can occur in the postoperative state of the temporal bone. PMID:28611633
A collaborative virtual reality environment for neurosurgical planning and training.
Kockro, Ralf A; Stadie, Axel; Schwandt, Eike; Reisch, Robert; Charalampaki, Cleopatra; Ng, Ivan; Yeo, Tseng Tsai; Hwang, Peter; Serra, Luis; Perneczky, Axel
2007-11-01
We have developed a highly interactive virtual environment that enables collaborative examination of stereoscopic three-dimensional (3-D) medical imaging data for planning, discussing, or teaching neurosurgical approaches and strategies. The system consists of an interactive console with which the user manipulates 3-D data using hand-held and tracked devices within a 3-D virtual workspace and a stereoscopic projection system. The projection system displays the 3-D data on a large screen while the user is working with it. This setup allows users to interact intuitively with complex 3-D data while sharing this information with a larger audience. We have been using this system on a routine clinical basis and during neurosurgical training courses to collaboratively plan and discuss neurosurgical procedures with 3-D reconstructions of patient-specific magnetic resonance and computed tomographic imaging data or with a virtual model of the temporal bone. Working collaboratively with the 3-D information of a large, interactive, stereoscopic projection provides an unambiguous way to analyze and understand the anatomic spatial relationships of different surgical corridors. In our experience, the system creates a unique forum for open and precise discussion of neurosurgical approaches. We believe the system provides a highly effective way to work with 3-D data in a group, and it significantly enhances teaching of neurosurgical anatomy and operative strategies.
Virtual estimates of fastening strength for pedicle screw implantation procedures
NASA Astrophysics Data System (ADS)
Linte, Cristian A.; Camp, Jon J.; Augustine, Kurt E.; Huddleston, Paul M.; Robb, Richard A.; Holmes, David R.
2014-03-01
Traditional 2D images provide limited use for accurate planning of spine interventions, mainly due to the complex 3D anatomy of the spine and close proximity of nerve bundles and vascular structures that must be avoided during the procedure. Our previously developed clinician-friendly platform for spine surgery planning takes advantage of 3D pre-operative images, to enable oblique reformatting and 3D rendering of individual or multiple vertebrae, interactive templating, and placement of virtual pedicle implants. Here we extend the capabilities of the planning platform and demonstrate how the virtual templating approach not only assists with the selection of the optimal implant size and trajectory, but can also be augmented to provide surrogate estimates of the fastening strength of the implanted pedicle screws based on implant dimension and bone mineral density of the displaced bone substrate. According to the failure theories, each screw withstands a maximum holding power that is directly proportional to the screw diameter (D), the length of the in-bone segm,ent of the screw (L), and the density (i.e., bone mineral density) of the pedicle body. In this application, voxel intensity is used as a surrogate measure of the bone mineral density (BMD) of the pedicle body segment displaced by the screw. We conducted an initial assessment of the developed platform using retrospective pre- and post-operative clinical 3D CT data from four patients who underwent spine surgery, consisting of a total of 26 pedicle screws implanted in the lumbar spine. The Fastening Strength of the planned implants was directly assessed by estimating the intensity - area product across the pedicle volume displaced by the virtually implanted screw. For post-operative assessment, each vertebra was registered to its homologous counterpart in the pre-operative image using an intensity-based rigid registration followed by manual adjustment. Following registration, the Fastening Strength was computed for each displaced bone segment. According to our preliminary clinical study, a comparison between Fastening Strength, displaced bone volume and mean voxel intensity showed similar results (p < 0.1) between the virtually templated plans and the post-operative outcome following the traditional clinical approach. This study has demonstrated the feasibility of the platform in providing estimates the pedicle screw fastening strength via virtual implantation, given the intrinsic vertebral geometry and bone mineral density, enabling the selection of the optimal implant dimension adn trajectory for improved strength.
Treatment of Temporal Bone Fractures
Diaz, Rodney C.; Cervenka, Brian; Brodie, Hilary A.
2016-01-01
Traumatic injury to the temporal bone can lead to significant morbidity or mortality and knowledge of the pertinent anatomy, pathophysiology of injury, and appropriate management strategies is critical for successful recovery and rehabilitation of such injured patients. Most temporal bone fractures are caused by motor vehicle accidents. Temporal bone fractures are best classified as either otic capsule sparing or otic capsule disrupting-type fractures, as such classification correlates well with risk of concomitant functional complications. The most common complications of temporal bone fractures are facial nerve injury, cerebrospinal fluid (CSF) leak, and hearing loss. Assessment of facial nerve function as soon as possible following injury greatly facilitates clinical decision making. Use of prophylactic antibiotics in the setting of CSF leak is controversial; however, following critical analysis and interpretation of the existing classic and contemporary literature, we believe its use is absolutely warranted. PMID:27648399
Treatment of Temporal Bone Fractures.
Diaz, Rodney C; Cervenka, Brian; Brodie, Hilary A
2016-10-01
Traumatic injury to the temporal bone can lead to significant morbidity or mortality and knowledge of the pertinent anatomy, pathophysiology of injury, and appropriate management strategies is critical for successful recovery and rehabilitation of such injured patients. Most temporal bone fractures are caused by motor vehicle accidents. Temporal bone fractures are best classified as either otic capsule sparing or otic capsule disrupting-type fractures, as such classification correlates well with risk of concomitant functional complications. The most common complications of temporal bone fractures are facial nerve injury, cerebrospinal fluid (CSF) leak, and hearing loss. Assessment of facial nerve function as soon as possible following injury greatly facilitates clinical decision making. Use of prophylactic antibiotics in the setting of CSF leak is controversial; however, following critical analysis and interpretation of the existing classic and contemporary literature, we believe its use is absolutely warranted.
Castro, Mario; Goycoolea, Marcos; Silva-Pinto, Verónica
2017-04-01
External ear canal exostosis is more prevalent in northern coastal groups than in the highlands, suggesting that ocean activities facilitate the appearance of exostosis. However, southern coastal groups exposed to colder ocean water have a lesser incidence of exostosis, possibly due to less duration of exposure. There was a high incidence of otitis media in all groups of native population in Chile. One coastal group had a higher incidence, presumably due to racial factors. This is a paleopathological and paleoepidemiological study in temporal bones which assesses external ear canal exostosis and otitis media in prehistoric and historic native populations in Chile. A total of 460 temporal bones were evaluated for exostosis (ex) and 542 temporal bones were evaluated for otitis media (om). The study involved four groups: (1) Prehistoric Coastal (400-1000 AD) populations in Northern Chile (Pisagua-Tiwanaku) (22 temporal bones ex; 28 om); (2) Prehistoric Highland (400-1000 AD) populations in Northern Chile (292 temporal bones ex; 334 om); (3) Pisagua-Regional Developments (coastal) in Northern Chile (1000-1450 AD) (66 temporal bones ex; 82 om); and (4) Historic (1500-1800 AD) coastal populations in Southern Chile (80 temporal bones ex: 18 Chonos, 62 Fuegians. 98 om: 22 Chonos, 76 Fuegians). Skulls were evaluated visually and with an operating microscope. In addition, the otitis media group was evaluated with Temporal bone radiology - -lateral XRays-Schuller view - to assess pneumatization as evidence of previous middle ear disease. Prehistoric northern coastal groups had an incidence of exostosis of 15.91%, the northern highlands group 1.37%, and the southern coastal group 1.25%. There were changes suggestive of otitis media in: Pisagua/Tiwanaku 53.57%; Pisagua/Regional Developments 70.73%; Northern Highlands population 47.90%; Chonos 63.64%; and Fuegian tribes 64.47%.
Multiscale musculoskeletal modelling, data–model fusion and electromyography-informed modelling
Zhang, J.; Heidlauf, T.; Sartori, M.; Besier, T.; Röhrle, O.; Lloyd, D.
2016-01-01
This paper proposes methods and technologies that advance the state of the art for modelling the musculoskeletal system across the spatial and temporal scales; and storing these using efficient ontologies and tools. We present population-based modelling as an efficient method to rapidly generate individual morphology from only a few measurements and to learn from the ever-increasing supply of imaging data available. We present multiscale methods for continuum muscle and bone models; and efficient mechanostatistical methods, both continuum and particle-based, to bridge the scales. Finally, we examine both the importance that muscles play in bone remodelling stimuli and the latest muscle force prediction methods that use electromyography-assisted modelling techniques to compute musculoskeletal forces that best reflect the underlying neuromuscular activity. Our proposal is that, in order to have a clinically relevant virtual physiological human, (i) bone and muscle mechanics must be considered together; (ii) models should be trained on population data to permit rapid generation and use underlying principal modes that describe both muscle patterns and morphology; and (iii) these tools need to be available in an open-source repository so that the scientific community may use, personalize and contribute to the database of models. PMID:27051510
Ginat, D T; Ferro, L; Gluth, M B
2016-12-01
We describe the temporal bone computed tomography (CT) findings of an unusual case of branchio-oto-renal syndrome with ectopic ossicles that are partially located in the middle cranial fossa. We also describe quantitative temporal bone CT assessment pertaining to cochlear implantation in the setting of anomalous cochlear anatomy associated with this syndrome.
Wu, Zhigang; Fu, Jun; Wang, Zhen; Li, Xiangdong; Li, Jing; Pei, Yanjun; Pei, Guoxian; Li, Dan; Guo, Zheng; Fan, Hongbin
2015-06-01
Although structural bone allografts have been used for years to treat large defects caused by tumour or trauma, selecting the most appropriate allograft is still challenging. The objectives of this study were to: (1) describe the establishment of a visual bone bank system and workflow of allograft selection, and (2) show mid-term follow-up results of patients after allograft implantation. Allografts were scanned and stored in Digital Imaging and Communications in Medicine (DICOM) files. Then, image segmentation was conducted and 3D model reconstructed to establish a visual bone bank system. Based on the volume registration method, allografts were selected after a careful matching process. From November 2010 to June 2013, with the help of the Computer-assisted Orthopaedic Surgery (CAOS) navigation system, the allografts were implanted in 14 patients to fill defects after tumour resection. By combining the virtual bone bank and CAOS, selection time was reduced and matching accuracy was increased. After 27.5 months of follow-up, the mean Musculoskeletal Tumor Society (MSTS) 93 functional score was 25.7 ± 1.1 points. Except for two patients with pulmonary metastases, 12 patents were alive without evidence of disease at the time this report was written. The virtual bone bank system was helpful for allograft selection, tumour excision and bone reconstruction, thereby improving the safety and effectiveness of limb-salvage surgery.
Pau, H; Fagan, P; Oleskevich, S
2006-11-01
To investigate the location of the scala media in relation to the round window niche in human temporal bones. Ten human temporal bones were investigated by radical mastoidectomy and promontory drill-out. Temporal bone laboratory. The distance from the scala media to the anterior edge of the round window niche, measured by Fisch's stapedectomy measuring cylinders. The scala media was identified at the transection point of a vertical line 1.6 to 2.2 mm (mean=1.8 mm; standard deviation=0.2) anterior to the anterior edge of the round window niche and a horizontal line 0.2 mm inferior to the lower border of the oval window. This report demonstrates the point of entry into the scala media via the promontory in fixed temporal bone models, which may provide a site of entry for stem cells and gene therapy insertion.
[Multi-center study of the Jenaer model of the temporal bone].
Schneider, G; Müller, A
2004-06-01
Preparing exercises at the temporal bone are a prerequisite for the knowledge of the anatomical special features of this region and for learning the fundamentals of the tympanic cavity surgery. Since however fewer human temporal bones are available, the search for back-up models already took place in the last years. Based on the experiences of the handling and visualization of CT data for the 3D-implant construction in the ent department Jena a temporal bone model was developed. The model was sent away to surgeons of different training. On the basis of identification of anatomical structures and evaluation of general parameters by means of a point system the model was evaluated. The Jenaer temporal bone model is suitable as entrance into the preparing exercises. The anatomical structures are good to identify for the beginner. The handling with drill and chisel can be learned.
Facial paralysis caused by metastasis of breast carcinoma to the temporal bone.
Lan, Ming-Ying; Shiao, An-Suey; Li, Wing-Yin
2004-11-01
Metastatic tumors to the temporal bone are very rare. The most common sites of origin of temporal bone metastases are breast, lung, kidney, gastrointestinal tract, larynx, prostate gland, and thyroid gland. The pathogenesis of spread to the temporal bone is most commonly by the hematogenous route. The common otologic symptoms that manifest with facial nerve paralysis are often thought to be due to a mastoid infection. Here is a report on a case of breast carcinoma presenting with otalgia, otorrhea, and facial paralysis for 2 months. The patient was initially diagnosed as mastoiditis, and later the clinical impression was revised to metastatic breast carcinoma to temporal bone, based on the pathologic findings. Metastatic disease should be considered as a possible etiology in patients with a clinical history of malignant neoplasms presenting with common otologic or vestibular symptoms, especially with facial nerve paralysis.
Comparing 3-dimensional virtual methods for reconstruction in craniomaxillofacial surgery.
Benazzi, Stefano; Senck, Sascha
2011-04-01
In the present project, the virtual reconstruction of digital osteomized zygomatic bones was simulated using different methods. A total of 15 skulls were scanned using computed tomography, and a virtual osteotomy of the left zygomatic bone was performed. Next, virtual reconstructions of the missing part using mirror imaging (with and without best fit registration) and thin plate spline interpolation functions were compared with the original left zygomatic bone. In general, reconstructions using thin plate spline warping showed better results than the mirroring approaches. Nevertheless, when dealing with skulls characterized by a low degree of asymmetry, mirror imaging and subsequent registration can be considered a valid and easy solution for zygomatic bone reconstruction. The mirroring tool is one of the possible alternatives in reconstruction, but it might not always be the optimal solution (ie, when the hemifaces are asymmetrical). In the present pilot study, we have verified that best fit registration of the mirrored unaffected hemiface and thin plate spline warping achieved better results in terms of fitting accuracy, overcoming the evident limits of the mirroring approach. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Anatomical study of the pigs temporal bone by microdissection.
Garcia, Leandro de Borborema; Andrade, José Santos Cruz de; Testa, José Ricardo Gurgel
2014-01-01
Initial study of the pig`s temporal bone anatomy in order to enable a new experimental model in ear surgery. Dissection of five temporal bones of Sus scrofa pigs obtained from UNIFESP - Surgical Skills Laboratory, removed with hole saw to avoid any injury and stored in formaldehyde 10% for better conservation. The microdissection in all five temporal bone had the following steps: inspection of the outer part, external canal and tympanic membrane microscopy, mastoidectomy, removal of external ear canal and tympanic membrane, inspection of ossicular chain and middle ear. Anatomically it is located at the same position than in humans. Some landmarks usually found in humans are missing. The tympanic membrane of the pig showed to be very similar to the human, separating the external and the middle ear. The middle ear`s appearance is very similar than in humans. The ossicular chain is almost exactly the same, as well as the facial nerve, showing the same relationship with the lateral semicircular canal. The temporal bone of the pigs can be used as an alternative for training in ear surgery, especially due the facility to find it and its similarity with temporal bone of the humans.
Primary Ewing's Sarcoma of the Temporal Bone: A Rare Case Report and Literature Review.
Gupta, Divya; Gulati, Achal; Purnima
2017-09-01
Ewing's sarcoma is a malignant, round cell tumor arising from the bones and primarily affecting children and adolescent, accounting for 3 % of all childhood malignancies. Although the long bones and the trunk are typically affected, rare cases of it involving isolated bones throughout the body have been reported. Involvement of the skull bones is rare, constituting 1-6 % of the total Ewing's sarcoma cases but those affecting the cranial bones are rarer still, constituting only 1 %. We describe an 8 months old infant having Ewing sarcoma, of the petrous and mastoid parts of temporal bone along with the occipital bone, whose clinical presentation mimicked mastoiditis with facial nerve palsy. We discuss the clinical and therapeutic course of an extensive primary Ewing sarcoma of the temporal bone, which was treated without performing surgery and review this entity's literature in detail.
Fischer, Gerrit; Stadie, Axel; Schwandt, Eike; Gawehn, Joachim; Boor, Stephan; Marx, Juergen; Oertel, Joachim
2009-05-01
The aim of the authors in this study was to introduce a minimally invasive superficial temporal artery to middle cerebral artery (STA-MCA) bypass surgery by the preselection of appropriate donor and recipient branches in a 3D virtual reality setting based on 3-T MR angiography data. An STA-MCA anastomosis was performed in each of 5 patients. Before surgery, 3-T MR imaging was performed with 3D magnetization-prepared rapid acquisition gradient echo sequences, and a high-resolution CT 3D dataset was obtained. Image fusion and the construction of a 3D virtual reality model of each patient were completed. In the 3D virtual reality setting, the skin surface, skull surface, and extra- and intracranial arteries as well as the cortical brain surface could be displayed in detail. The surgical approach was successfully visualized in virtual reality. The anatomical relationship of structures of interest could be evaluated based on different values of translucency in all cases. The closest point of the appropriate donor branch of the STA and the most suitable recipient M(3) or M(4) segment could be calculated with high accuracy preoperatively and determined as the center point of the following minicraniotomy. Localization of the craniotomy and the skin incision on top of the STA branch was calculated with the system, and these data were transferred onto the patient's skin before surgery. In all cases the preselected arteries could be found intraoperatively in exact agreement with the preoperative planning data. Successful extracranial-intracranial bypass surgery was achieved without stereotactic neuronavigation via a preselected minimally invasive approach in all cases. Subsequent enlargement of the craniotomy was not necessary. Perioperative complications were not observed. All bypasses remained patent on follow-up. With the application of a 3D virtual reality planning system, the extent of skin incision and tissue trauma as well as the size of the bone flap was minimal. The closest point of the appropriate donor branch of the STA and the most suitable recipient M(3) or M(4) segment could be preoperatively determined with high accuracy so that the STA-MCA bypass could be safely and effectively performed through an optimally located minicraniotomy with a mean diameter of 22 mm without the need for stereotactic guidance.
Navigation system for robot-assisted intra-articular lower-limb fracture surgery.
Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja
2016-10-01
In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.
Vesseur, A C; Verbist, B M; Westerlaan, H E; Kloostra, F J J; Admiraal, R J C; van Ravenswaaij-Arts, C M A; Free, R H; Mylanus, E A M
2016-12-01
To provide an overview of anomalies of the temporal bone in CHARGE syndrome relevant to cochlear implantation (CI), anatomical structures of the temporal bone and the respective genotypes were analysed. In this retrospective study, 42 CTs of the temporal bone of 42 patients with CHARGE syndrome were reviewed in consensus by two head-and-neck radiologists and two otological surgeons. Anatomical structures of the temporal bone were evaluated and correlated with genetic data. Abnormalities that might affect CI surgery were seen, such as a vascular structure, a petrosquamosal sinus (13 %), an underdeveloped mastoid (8 %) and an aberrant course of the facial nerve crossing the round window (9 %) and/or the promontory (18 %). The appearance of the inner ear varied widely: in 77 % of patients all semicircular canals were absent and the cochlea varied from normal to hypoplastic. A stenotic cochlear aperture was observed in 37 %. The middle ear was often affected with a stenotic round (14 %) or oval window (71 %). More anomalies were observed in patients with truncating mutations than with non-truncating mutations. Temporal bone findings in CHARGE syndrome vary widely. Vascular variants, aberrant route of the facial nerve, an underdeveloped mastoid, aplasia of the semicircular canals, and stenotic round window may complicate cochlear implantation.
Optical 3D surface digitizing in forensic medicine: 3D documentation of skin and bone injuries.
Thali, Michael J; Braun, Marcel; Dirnhofer, Richard
2003-11-26
Photography process reduces a three-dimensional (3D) wound to a two-dimensional level. If there is a need for a high-resolution 3D dataset of an object, it needs to be three-dimensionally scanned. No-contact optical 3D digitizing surface scanners can be used as a powerful tool for wound and injury-causing instrument analysis in trauma cases. The 3D skin wound and a bone injury documentation using the optical scanner Advanced TOpometric Sensor (ATOS II, GOM International, Switzerland) will be demonstrated using two illustrative cases. Using this 3D optical digitizing method the wounds (the virtual 3D computer model of the skin and the bone injuries) and the virtual 3D model of the injury-causing tool are graphically documented in 3D in real-life size and shape and can be rotated in the CAD program on the computer screen. In addition, the virtual 3D models of the bone injuries and tool can now be compared in a 3D CAD program against one another in virtual space, to see if there are matching areas. Further steps in forensic medicine will be a full 3D surface documentation of the human body and all the forensic relevant injuries using optical 3D scanners.
The ASSERT Virtual Machine Kernel: Support for Preservation of Temporal Properties
NASA Astrophysics Data System (ADS)
Zamorano, J.; de la Puente, J. A.; Pulido, J. A.; Urueña
2008-08-01
A new approach to building embedded real-time software has been developed in the ASSERT project. One of its key elements is the concept of a virtual machine preserving the non-functional properties of the system, and especially real-time properties, all the way down from high- level design models down to executable code. The paper describes one instance of the virtual machine concept that provides support for the preservation of temporal properties both at the source code level —by accept- ing only "legal" entities, i.e. software components with statically analysable real-tim behaviour— and at run-time —by monitoring the temporal behaviour of the system. The virtual machine has been validated on several pilot projects carried out by aerospace companies in the framework of the ASSERT project.
NASA Astrophysics Data System (ADS)
Borgers, Charlotte; van Wieringen, Astrid; D'hondt, Christiane; Verhaert, Nicolas
2018-05-01
The cochlea is the main contributor in bone conduction perception. Measurements of differential pressure in the cochlea give a good estimation of the cochlear input provided by bone conduction stimulation. Recent studies have proven the feasibility of intracochlear pressure measurements in chinchillas and in human temporal bones to study bone conduction. However, similar measurements in fresh-frozen whole human cadaveric heads could give a more realistic representation of the five different transmission pathways of bone conduction to the cochlea compared to human temporal bones. The aim of our study is to develop and validate a framework for intracochlear pressure measurements to evaluate different aspects of bone conduction in whole human cadaveric heads. A proof of concept describing our experimental setup is provided together with the procedure. Additionally, we also present a method to fix the stapes footplate in order to simulate otosclerosis in human temporal bones. The effectiveness of this method is verified by some preliminary results.
Ahmed, Sameer; VanKoevering, Kyle K; Kline, Stephanie; Green, Glenn E; Arts, H Alexander
2017-10-01
To explore the perioperative utility of three-dimensionally (3D)-printed temporal bone models of patients undergoing repair of lateral skull base defects and spontaneous cerebrospinal fluid leaks with the middle cranial fossa approach. Case series. 3D-printed temporal bone models-based on patient-specific, high-resolution computed tomographic imaging-were constructed using inexpensive polymer materials. Preoperatively, the models demonstrated the extent of temporal lobe retraction necessary to visualize the proposed defects in the lateral skull base. Also preoperatively, Silastic sheeting was arranged across the modeled tegmen, marked, and cut to cover all of the proposed defect sites. The Silastic sheeting was then sterilized and subsequently served as a precise intraoperative template for a synthetic dural replacement graft. Of note, these grafts were customized without needing to retract the temporal lobe. Five patients underwent the middle cranial fossa approach assisted by 3D-printed temporal bone models to repair tegmen defects and spontaneous cerebrospinal fluid leaks. No complications were encountered. The prefabricated dural repair grafts were easily placed and fit precisely onto the middle fossa floor without any additional modifications. All defects were covered as predicted by the 3D temporal bone models. At their postoperative visits, all five patients maintained resolution of their spontaneous cerebrospinal fluid leaks. Inexpensive 3D-printed temporal bone models of tegmen defects can serve as beneficial adjuncts during lateral skull base repair. The models provide a panoramic preoperative view of all tegmen defects and allow for custom templating of dural grafts without temporal lobe retraction. 4 Laryngoscope, 127:2347-2351, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Embodiment, Virtual Space, Temporality and Interpersonal Relations in Online Writing
ERIC Educational Resources Information Center
Adams, Catherine; van Manen, Max
2006-01-01
In this paper we discuss how online seminar participants experience dimensions of embodiment, virtual space, interpersonal relations, and temporality; and how interacting through reading-writing, by means of online technologies, creates conditions, situations, and actions of pedagogical influence and relational affectivities. We investigate what…
Golomb, Meredith R.; Warden, Stuart J.; Fess, Elaine; Rabin, Bryan; Yonkman, Janell; Shirley, Bridget; Burdea, Grigore C.
2015-01-01
Virtual reality videogames can be used to motivate rehabilitation, and telerehabilitation can be used to improve access to rehabilitation. These uses of technology to improve health outcomes are a burgeoning area of rehabilitation research. So far, there is a lack of reports of long-term outcomes of these types of interventions. The authors report a 15-year-old boy with hemiplegic cerebral palsy and epilepsy because of presumed perinatal stroke who improved his plegic hand function and increased his plegic forearm bone health during a 14-month virtual reality videogame hand telerehabilitation intervention. A total of 14 months after the intervention ended, repeat evaluation demonstrated maintenance of both increased hand function and forearm bone health. The implications of this work for the future of rehabilitation in children with neurological disabilities are discussed in this article. PMID:21383228
Golomb, Meredith R; Warden, Stuart J; Fess, Elaine; Rabin, Bryan; Yonkman, Janell; Shirley, Bridget; Burdea, Grigore C
2011-03-01
Virtual reality videogames can be used to motivate rehabilitation, and telerehabilitation can be used to improve access to rehabilitation. These uses of technology to improve health outcomes are a burgeoning area of rehabilitation research. So far, there is a lack of reports of long-term outcomes of these types of interventions. The authors report a 15-year-old boy with hemiplegic cerebral palsy and epilepsy because of presumed perinatal stroke who improved his plegic hand function and increased his plegic forearm bone health during a 14-month virtual reality videogame hand telerehabilitation intervention. A total of 14 months after the intervention ended, repeat evaluation demonstrated maintenance of both increased hand function and forearm bone health. The implications of this work for the future of rehabilitation in children with neurological disabilities are discussed in this article.
Vaughan, Patrick E; Orth, Michael W; Haut, Roger C; Karcher, Darrin M
2016-01-01
While conventional mechanical testing has been regarded as a gold standard for the evaluation of bone heath in numerous studies, with recent advances in medical imaging, virtual methods of biomechanics are rapidly evolving in the human literature. The objective of the current study was to evaluate the feasibility of determining the elastic and failure properties of poultry long bones using established methods of analysis from the human literature. In order to incorporate a large range of bone sizes and densities, a small number of specimens were utilized from an ongoing study of Regmi et al. (2016) that involved humeri and tibiae from 3 groups of animals (10 from each) including aviary, enriched, and conventional housing systems. Half the animals from each group were used for 'training' that involved the development of a regression equation relating bone density and geometry to bending properties from conventional mechanical tests. The remaining specimens from each group were used for 'testing' in which the mechanical properties from conventional tests were compared to those predicted by the regression equations. Based on the regression equations, the coefficients of determination for the 'test' set of data were 0.798 for bending bone stiffness and 0.901 for the yield (or failure) moment of the bones. All regression slopes and intercepts values for the tests versus predicted plots were not significantly different from 1 and 0, respectively. The study showed the feasibility of developing future methods of virtual biomechanics for the evaluation of poultry long bones. With further development, virtual biomechanics may have utility in future in vivo studies to assess laying hen bone health over time without the need to sacrifice large groups of animals at each time point. © 2016 Poultry Science Association Inc.
Bone Density Development of the Temporal Bone Assessed by Computed Tomography.
Takahashi, Kuniyuki; Morita, Yuka; Ohshima, Shinsuke; Izumi, Shuji; Kubota, Yamato; Horii, Arata
2017-12-01
The temporal bone shows regional differences in bone development. The spreading pattern of acute mastoiditis shows age-related differences. In infants, it spreads laterally and causes retroauricular swelling, whereas in older children, it tends to spread medially and causes intracranial complications. We hypothesized that bone maturation may influence the spreading pattern of acute mastoiditis. Eighty participants with normal hearing, aged 3 months to 42 years, participated in this study. Computed tomography (CT) values (Hounsfield unit [HU]) in various regions of the temporal bone, such as the otic capsule (OC), lateral surface of the mastoid cavity (LS), posterior cranial fossa (PCF), and middle cranial fossa (MCF), were measured as markers of bone density. Bone density development curves, wherein CT values were plotted against age, were created for each region. The age at which the CT value exceeded 1000 HU, which is used as an indicator of bone maturation, was calculated from the development curves and compared between the regions. The OC showed mature bone at birth, whereas the LS, PCF, and MCF showed rapid maturation in early childhood. However, there were significant regional differences in the ages of maturation: 1.7, 3.9, and 10.8 years for the LS, PCF, and MCF, respectively. To our knowledge, this is the first report to show regional differences in the maturation of temporal bone, which could partly account for the differences in the spreading pattern of acute mastoiditis in individuals of different ages.
Školoudík, Lukáš; Chrobok, Viktor; Kočí, Zuzana; Popelář, Jiří; Syka, Josef; Laco, Jan; Filipová, Alžběta; Syková, Eva; Filip, Stanislav
2018-06-03
Temporal bone reconstruction is a persisting problem following middle ear cholesteatoma surgery. Seeking to advance the clinical transfer of stem cell therapy we attempted the reconstruction of temporal bone using a composite bioartificial graft based on a hydroxyapatite bone scaffold combined with human bone marrow-derived mesenchymal stromal cells (hBM-MSCs). The aim of this study was to evaluate the effect of the combined biomaterial on the healing of postoperative temporal bone defects and the preservation of physiological hearing functions in a guinea pig model. The treatment's effect could be observed at 1 and 2 months after implantation of the biomaterial, as opposed to the control group. The clinical evaluation of our results included animal survival, clinical signs of an inflammatory response, and exploration of the tympanic bulla. Osteogenesis, angiogenesis, and inflammation were evaluated by histopathological analyses, whereas hBM-MSCs survival was evaluated by immunofluorescence assays. Hearing capacity was evaluated by objective audiometric methods, i.e. auditory brainstem responses and otoacoustic emission. Our study shows that hBM-MSCs, in combination with hydroxyapatite scaffolds, improves the repair of bone defects providing a safe and effective alternative in their treatment following middle ear surgery due to cholesteatoma.
Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C
2014-01-01
Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.
Martínez, I; Arsuaga, J L
1997-01-01
Three well-preserved crania and 22 temporal bones were recovered from the Sima de los Huesos Middle Pleistocene site up to and including the 1994 field season. This is the largest sample of hominid temporal bones known from a single Middle Pleistocene site and it offers the chance to characterize the temporal bone morphology of an European Middle Pleistocene population and to study the phylogenetic relationships of the SH sample with other Upper and Middle Pleistocene hominids. We have carried out a cladistic analysis based on nine traits commonly used in phylogenetic analysis of Middle and Late Pleistocene hominids: shape of the temporal squama superior border, articular eminence morphology, contribution of the sphenoid bone to the median glenoid wall, postglenoid process projection, tympanic plate orientation, presence of the styloid process, mastoid process projection, digastric groove morphology and anterior mastoid tubercle. We have found two autapomorphies on the Home erectus temporal bone: strong reduction of the postglenoid process and absence of the styloid process. Modern humans, Neandertals and the Middle Pleistocene fossils from Europe and Africa constitute a clade characterized by a convex superior border of the temporal squama. The European Middle Pleistocene fossils from Sima de los Huesos, Petralona, Steinheim, Bilzingsleben and Castel di Guido share a Neandertal apomorphy: a relatively flat articular eminence. The fossils from Ehringsdorf, La Chaise Suardi and Biache-Saint-Vaast also display another Neandertal derived trait: an anteriorly obliterated digastric groove. Modern humans and the African Middle Pleistocene fossils share a synapomorphy: a sagittally orientated tympanic plate.
Inal, Mikail; Muluk, Nuray B; Dağ, Ersel; Arıkan, Osman K; Kara, Simay A
2015-01-01
High jugular bulb (HJB) may be detected unilaterally or bilaterally in temporal bone high resolution computerized tomography (HRCT). In this retrospective study, we investigated the pitfalls and important surgical distances in patients with unilateral and bilateral HJB via temporal bone HRCT. In this preliminary report, the study group consisted of 20 adult patients (12 male, 8 female), or 40 ears, all of which underwent temporal bone HRCT. We divided them into groups that consisted of bilateral HJB (14 ears), unilateral HJB (13 ears), and control (No HJB, 13 ears). The anotomical relationships of the sigmoid sinus, jugular bulb, and carotid artery with several landmarks in the temporal bone were studied via temporal bone axial and coronal HRCT. The shortest distances between certain points were measured. These measurements were analyzed in respect to pneumatization. Dehiscence on the jugular bulb (JB) and internal carotid artery (ICA) and the dominance of JB were also evaluated for all of the groups. In the axial sections of the temporal bone HRCTs, the sigmois sinus (SS)-external auditory canal (EAC) distance of the bilateral HJB group (14.00±1.17 mm) was significantly lower than that of the control group (16.46±2.14 mm). The JB-posteromedial points of the umbo on the ear drum (ED) distance of the bilateral HJB (6.28±1.72 mm) and the unilateral HJB groups (7.23±2.00 mm) were significantly lower than that of the control group (11.15±2.30 mm). In the coronal sections of the temporal bone HRCT, the JB-F distance of the bilateral HJB group (5.42±2.10 mm) was significantly lower than that of the control group (8.30±2.28 mm). As the mastoid pneumatisation and mastoid volume increased, the percentage of ICA-dehiscence and the percentage of JB-dehiscence increased. In subjects with well-pneumatised mastoids, the doctors should be aware of the increased risk of ICA-dehiscence and JB-dehiscence. These measurements should be done in greater series to yield more thorough knowledge.
Usefulness of temporal bone prototype for drilling training: A prospective study.
Aussedat, C; Venail, F; Nguyen, Y; Lescanne, E; Marx, M; Bakhos, D
2017-12-01
Dissection of cadaveric temporal bones (TBs) is considered the gold standard for surgical training in otology. For many reasons, access to the anatomical laboratory and cadaveric TBs is difficult for some facilities. The aim of this prospective and comparative study was to evaluate the usefulness of a physical TB prototype for drilling training in residency. Prospective study. Tertiary referral centre. Thirty-four residents were included. Seventeen residents (mean age 26.7±1.6) drilled on only cadaveric TBs ("traditional" group), in the traditional training method, while seventeen residents (mean age 26.5±1.7) drilled first on a prototype and then on a cadaveric TB ("prototype" group). Drilling performance was assessed using a validated scale. Residents completed a mastoid image before and after each drilling to enable evaluation of mental representations of the mastoidectomy. No differences were observed between the groups with respect to age, drilling experience and level of residency. Regarding drilling performance, we found a significant difference across the groups, with a better score in the prototype group (P=.0007). For mental representation, the score was statistically improved (P=.0003) after drilling in both groups, suggesting that TB drilling improves the mental representation of the mastoidectomy whether prototype or cadaveric TB is used. The TB prototype improves the drilling performance and mental representation of the mastoidectomy in the young resident population. A drilling simulation with virtual or physical systems seems to be a beneficial tool to improve TB drilling. © 2017 John Wiley & Sons Ltd.
Clinical features and radiological evaluation of otic capsule sparing temporal bone fractures.
Song, S W; Jun, B C; Kim, H
2017-03-01
To evaluate the clinical and radiological aspects of otic capsule sparing temporal bone fractures. Using medical records, 188 temporal bones of 173 patients with otic capsule sparing temporal bone fractures were evaluated. Otoscopic findings and symptoms, facial paralysis, and hearing loss were assessed. Using regional analysis, 7 fractures were classified as type I, 85 as type II, 169 as type III and 114 as type IV. Fourteen of the 17 facial paralysis cases improved to House-Brackmann grade II or lower at an average of 57.6 days after the initial evaluation. Thirty-one patients underwent initial and follow-up pure tone audiometry examinations. The air-bone gap closed significantly from 27.2 dB at an average of 21.8 days post-trauma to 19.6 dB at an average of 79.9 days post-trauma, without the need for surgical intervention. Initial conservative treatment for facial paralysis or conductive hearing loss is possible in otic capsule sparing fracture cases after careful evaluation of the patient.
Pediatric temporal bone fractures: A case series.
Waissbluth, S; Ywakim, R; Al Qassabi, B; Torabi, B; Carpineta, L; Manoukian, J; Nguyen, L H P
2016-05-01
Temporal bone fractures are relatively common findings in patients with head trauma. The aim of this study was to evaluate the characteristics of temporal bone fractures in the pediatric population. Retrospective case series. Tertiary care pediatric academic medical center. The medical records of patients aged 18 years or less diagnosed with a temporal bone fracture at the Montreal Children's Hospital from January 2000 to August 2014 were reviewed. Patient demographics, clinical presentation, mechanism of injury and complications were analyzed. Imaging studies and audiograms were also evaluated. Out of 323 patients presenting to the emergency department with a skull fracture, 61 presented with a temporal bone fracture. Of these, 5 presented with bilateral fractures. 47 patients had associated fractures, and 3 patients deceased. We observed a male to female ratio of 2.8:1, and the average age was 9.5 years. Motor vehicle accidents were the primary mechanism of injury (53%), followed by falls (21%) and bicycle or skateboard accidents (10%). The most common presenting signs included hemotympanum, decreased or loss of consciousness, facial swelling and nausea and vomiting. 8 patients had otic involvement on computed tomography scans, and 30 patients had documented hearing loss near the time of accident with a majority being conductive hearing loss. 17 patients underwent surgical management of intracranial pressure. In children, fractures of the temporal bone were most often caused by motor vehicle accidents and falls. It is common for these patients to have associated fractures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Transparent model of temporal bone and vestibulocochlear organ made by 3D printing.
Suzuki, Ryoji; Taniguchi, Naoto; Uchida, Fujio; Ishizawa, Akimitsu; Kanatsu, Yoshinori; Zhou, Ming; Funakoshi, Kodai; Akashi, Hideo; Abe, Hiroshi
2018-01-01
The vestibulocochlear organ is composed of tiny complex structures embedded in the petrous part of the temporal bone. Landmarks on the temporal bone surface provide the only orientation guide for dissection, but these need to be removed during the course of dissection, making it difficult to grasp the underlying three-dimensional structures, especially for beginners during gross anatomy classes. We report herein an attempt to produce a transparent three-dimensional-printed model of the human ear. En bloc samples of the temporal bone from donated cadavers were subjected to computed tomography (CT) scanning, and on the basis of the data, the surface temporal bone was reconstructed with transparent resin and the vestibulocochlear organ with white resin to create a 1:1.5 scale model. The carotid canal was stuffed with red cotton, and the sigmoid sinus and internal jugular vein were filled with blue clay. In the inner ear, the internal acoustic meatus, cochlea, and semicircular canals were well reconstructed in detail with white resin. The three-dimensional relationships of the semicircular canals, spiral turns of the cochlea, and internal acoustic meatus were well recognizable from every direction through the transparent surface resin. The anterior semicircular canal was obvious immediately beneath the arcuate eminence, and the topographical relationships of the vestibulocochlear organ and adjacent great vessels were easily discernible. We consider that this transparent temporal bone model will be a very useful aid for better understanding of the gross anatomy of the vestibulocochlear organ.
Hennersdorf, Florian; Friese, Natascha; Löwenheim, Hubert; Tropitzsch, Anke; Ernemann, Ulrike; Bisdas, Sotirios
2014-06-01
Goldenhar syndrome is a developmental disorder presenting with orofacial and vertebral anomalies, which are also accompanied by abnormalities in other organs. We examined temporal bone changes with special emphasis on inner ear abnormalities in these patients. A retrospective review of 7 new cases in addition to a previously published series of 14 cases with clinically diagnosed Goldenhar syndrome was carried out to search for inner ear anomalies. In addition, temporal bone imaging studies from the literature were summarized and compared with our results. Departments of Neuroradiology and Otorhinolaryngology at a university hospital. In addition to the previous series of 14 patients, 7 new patients with Goldenhar syndrome were identified. Patients underwent otologic examination, audiometric studies, and high-resolution computed tomography (CT) or magnetic resonance imaging (MRI) of the temporal bone. Temporal bone changes and specifically inner ear malformations. Nineteen of 21 patients showed changes of the external and middle ear correlating with the literature. Seven of 21 patients showed inner ear abnormalities constituting one-third of all patients. These ranged from mild such as vestibular enlargement to severe defects such as cochlear hypoplasia and common cavity. Inner ear abnormalities were present in one-third of patients. Although in some cases, these might not be of clinical significance, some patients show severe defects of the inner ear requiring more complex hearing loss therapy. Therefore, imaging of the temporal bone structures is important in the care of these patients.
Kardos, Zsófia; Oláh, Csaba; Sepsi, Mariann; Sas, Attila; Kostyál, László; Bóta, Tünde; Bhattoa, Harjit Pal; Hodosi, Katalin; Kerekes, György; Tamási, László; Bereczki, Dániel; Szekanecz, Zoltán
2018-05-01
Assessment of intracranial vessels includes transcranial Doppler (TCD). TCD performance requires intact temporal acoustic windows (TAW). Failure of TAW (TAWF) is present in 8-20% of people. There have been no reports on TAWF in rheumatoid arthritis (RA). Altogether, 62 female RA patients were included. Among them, 20 were MTX-treated and biologic-free, 20 received infliximab, and 22 tocilizumab. The controls included 60 non-RA women. TAWF, temporal bone thickness, and texture were determined by ultrasound and CT. BMD and T-scores of multiple bones were determined by DEXA. Several bone biomarkers were assessed by ELISA. In RA, 54.8% of the patients had TAWF on at least one side. Neither TAW could be identified in 34% of RA subjects. In contrast, only 20.0% of control subjects had TAWF on either or both sides (p < 0.001). In RA vs controls, 53.0 vs 2.9% of subjects exerted the trilayer, "sandwich-like" structure of TAW (p < 0.001). Finally, in RA vs controls, the mean temporal bone thickness values of the right TAW were 3.58 ± 1.43 vs 2.92 ± 1.22 mm (p = NS), while those of the left TAW were 4.16 ± 1.56 vs 2.90 ± 1.16 mm (p = 0.001). There was close association between TAWF, bone thickness, and texture (p < 0.05). These TAW parameters all correlated with age; however, TAW failure and texture also correlated with serum osteoprotegerin. TAW bone thickness inversely correlated with hip BMD (p < 0.05). TAWF, thicker, and heterogeneous temporal bones were associated with RA. These features have been associated with bone loss and OPG production. Bone loss seen in RA may result in OPG release and stimulation of bone formation around TAW.
Hulka, G F; McElveen, J T
1998-09-01
Canal wall down and intact canal wall tympanomastoidectomy represent two surgical approaches to middle ear pathology. The authors hypothesize that there is a difference in the ability to view structures in the middle ear between these two methods. Depending on the individual, many surgeons have used the two different techniques of intact canal wall and canal wall down tympanomastoidectomy for approaching the middle ear. However, opinions conflict as to which approach provides the best visualization of different locations in the middle ear. This study prospectively evaluated temporal bones to determine the differences in visualizing structures of the middle ear using these two approaches. Twelve temporal bones underwent a standardized canal wall down tympanomastoidectomy using a reversible canal wall down technique. All bones were viewed in two dissections: intact canal wall and canal wall down preparations. Four points previously had been marked on each temporal bone in randomly assigned colors. These points include the sinus tympani, posterior crus of stapes, lateral epitympanum, and the Eustachian tube orifice. An observer blinded to the purpose of the study, color, and number of locations recorded the color and location of marks observed within the temporal bones. Randomized bones of two separate settings were viewed such that each bone was viewed in both the canal wall down and the intact canal wall preparations. A significant difference was noted in the ability to observe middle ear pathology between the intact canal wall versus canal wall down tympanomastoidectomy, with the latter showing superiority (p < 0.001). Of the four subsites, the sinus tympani, posterior crus of stapes, and lateral epitympanum were observed more frequently with the canal wall down. There was no significant difference in the ability to observe the Eustachian tube orifice between the two techniques. Statistical analysis shows good reproducibility and randomization of this study. The canal wall down tympanomastoidectomy allowed for superior viewing of the three locations, sinus tympanic, posterior crus of stapes, and lateral at the tympanum, as they were marked in the study. This study shows the potential for improved visualization via the canal wall down tympanomastoidectomy. A significant amount of literature written by individuals and otology group practices is available retrospectively comparing the advantages and disadvantages of intact canal wall versus canal wall down mastoidectomy procedures for approaching middle ear pathology. In the interest of objectively evaluating the differences between these two approaches, we have studied temporal bones in a prospective randomized, blinded study comparing the two. Twelve bones were used and observed twice, once in each of 2 sessions. All bones were viewed in two dissections: intact canal wall and canal wall down mastoidectomy. Four points were marked on each temporal bone in three different colors applied in a randomized order to eliminate observer expectation. The four points marked include sinus tympani, posterior crus of the stapes footplate, lateral epitympanum, and Eustachian tube orifice. Both intact canal wall and canal wall down bones were provided randomly to the observer at each viewing session. Before the observer was allowed to see the dissections, those requiring replacement of the canal for the first session of the study had this done in a method using native posterior bony canal. Temporal bones were presented to an expert otologist in a randomized fashion with each temporal bone being placed in a temporal bone bowl holder and specialized framework, allowing for rotation and repositioning approximating the experience in an operating room setting. For each temporal bone, the observer filled in a questionnaire describing his or her observations by denoting both location and color of marks observed. (ABSTRACT TRUNCATED)
Cerebrospinal otorrhoea--a temporal bone report.
Walby, A P
1988-05-01
Spontaneous cerebrospinal otorrhoea is a rare complication of a cholesteatoma. The histological findings in a temporal bone from such a case are reported. The cholesteatoma had eroded deeply through the vestibule into the internal auditory meatus.
Hearing and Mortality Outcomes following Temporal Bone Fractures.
Honeybrook, Adam; Patki, Aniruddha; Chapurin, Nikita; Woodard, Charles
2017-12-01
The aim of this article is to determine hearing and mortality outcomes following temporal bone fractures. Retrospective chart review was performed of 152 patients diagnosed with a temporal bone fracture presenting to the emergency room at a tertiary care referral center over a 10-year period. Utilizing Patients' previously obtained temporal bone computed tomographic scans and audiograms, fractures were classified based on several classification schemes. Correlations between fracture patterns, mortality, and hearing outcomes were analyzed using χ 2 tests. Ossicular chain disruption was seen in 11.8% of patients, and otic capsule violation was seen in 5.9%; 22.7% of patients presented for audiologic follow-up. Seventeen patients with conductive hearing loss had air-bone gaps of 26 ± 7.5 dB (500 Hz), 27 ± 6.8 dB (1,000 Hz), 18 ± 6.2 dB (2,000 Hz), and 32 ± 7.7 dB (4,000 Hz). Two cases of profound sensorineural hearing loss were associated with otic capsule violation. No fracture classification scheme was predictive of hearing loss, although longitudinal fractures were statistically associated with ossicular chain disruption ( p < 0.01). Temporal bone fractures in patients older than 60 years carried a relative risk of death of 3.15 compared with those younger than 60 years. The average magnitude of conductive hearing loss resulting from temporal bone fracture ranged from 18 to 32 dB in this cohort. Classification of fracture type was not predictive of hearing loss, despite the statistical association between ossicular chain disruption and longitudinal fractures. This finding may be due to the low follow-up rates of this patient population. Physicians should make a concerted effort to ensure that audiological monitoring is executed to prevent and manage long-term hearing impairment.
Facial nerve palsy associated with a cystic lesion of the temporal bone.
Kim, Na Hyun; Shin, Seung-Ho
2014-03-01
Facial nerve palsy results in the loss of facial expression and is most commonly caused by a benign, self-limiting inflammatory condition known as Bell palsy. However, there are other conditions that may cause facial paralysis, such as neoplastic conditions of the facial nerve, traumatic nerve injury, and temporal bone lesions. We present a case of facial nerve palsy concurrent with a benign cystic lesion of the temporal bone, adjacent to the tympanic segment of the facial nerve. The patient's symptoms subsided after facial nerve decompression via a transmastoid approach.
Cost effective use of audiograms after pediatric temporal bone fractures.
Frisenda, Julia L; Schroeder, James W; Ryan, Maura E; Valika, Taher S; Billings, Kathleen R
2015-11-01
To identify the relationship of pediatric temporal fractures to the incidence and type of hearing loss present. To analyze the timing and utility of audiometric testing in children with temporal bone fractures. Retrospective case series of 50 pediatric patients with temporal bone fractures who were treated at an urban, tertiary care children's hospital from 2008 to 2014. A statistical analysis of predictors of hearing loss after temporal bone fracture was performed. Fifty-three fractures (69.7%) in 50 patients involved the petrous portion of the temporal bone. The mean age of patients was 7.13 years, and 39 (73.6%) were male. A fall was the most common mechanism of injury in 28 (52.8%) patients, followed by crush injury (n=14, 26.2%), and vehicular trauma (n=10, 18.9%). All otic capsule violating fractures were associated with a sensorineural hearing loss (n=4, 7.5%, p=0.002). Three of four otic capsule sparing fractures were associated with ossicular dislocation, with a corresponding mixed or conductive hearing loss on follow up audiometric testing. The majority of otic capsule sparing fracture patients (n=19/43, 44.2%) who had follow up audiograms had normal hearing, and those with otic capsule violating fractures were statistically more likely to have persistent hearing loss than those with otic capsule sparing fractures (p=0.01). Patients with otic capsule violating fractures or those with ossicular disruption are at higher risk for persistent hearing loss. Cost-saving may be accrued by selecting only those patients at high risk for persistent hearing loss for audiometric testing after temporal bone fractures. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Sikka, Kapil; Kairo, Arvind; Singh, Chirom Amit; Roy, T S; Lalwani, Sanjeev; Kumar, Rakesh; Thakar, Alok; Sharma, Suresh C
2017-09-01
To evaluate the extent of intracochlear damage by histologic assessment of cadaveric temporal bones after insertion of cochlear implants by: round window approach and cochleostomy approach. Cochlear implantation was performed by transmastoid facial recess approach in 10 human cadaveric temporal bones. In 5 temporal bones, electrode insertion was acheieved by round window approach and in the remaining 5 bones, by cochleostomy approach. The bones were fixed, decalcified, sectioned and studied histologically. Grading of insertion trauma was assessed. In the round window insertion group, 2 bones had to be excluded from the study: one was damaged during handling with electrode extrusion and another bone did not show any demonstrable identifiable cochlear structure. Out of the 3 temporal bones, a total of 35 sections were examined: 24 demonstrated normal cochlea, 4 had basilar membrane bulging and 7 had fracture of bony spiral lamina. In the cochleostomy group, histology of 2 bones had to be discarded due to lack of any identifiable inner ear structures. Out of the 3 bones studied, 18 sections were examined: only 3 were normal, 4 sections had some bulge in spiral lamina and 11 had fracture of bony spiral lamina. The fracture of spiral lamina and bulge of basement membrane proportion is relatively higher if we perform cochleostomy as compared to round window approach. Therefore, round window insertion is relatively less traumatic as compared to cochleostomy. However, our sample size was very small and a study with a larger sample is required to further validate these findings.
Utility of 3D printed temporal bones in pre-surgical planning for complex BoneBridge cases.
Mukherjee, Payal; Cheng, Kai; Flanagan, Sean; Greenberg, Simon
2017-08-01
With the advent of single-sided hearing loss increasingly being treated with cochlear implantation, bone conduction implants are reserved for cases of conductive and mixed hearing loss with greater complexity. The BoneBridge (BB, MED-EL, Innsbruck, Austria) is an active fully implantable device with no attenuation of sound energy through soft tissue. However, the floating mass transducer (FMT) part of the device is very bulky, which limits insertion in complicated ears. In this study, 3D printed temporal bones of patients were used to study its utility in preoperative planning on complicated cases. Computed tomography (CT) scans of 16 ears were used to 3D print their temporal bones. Three otologists graded the use of routine preoperative planning provided by MED-EL and that of operating on the 3D printed bone of the patient. Data were collated to assess the advantage and disadvantage of the technology. There was a statistically significant benefit in using 3D printed temporal bones to plan surgery for difficult cases of BoneBridge surgery compared to the current standard. Surgeons preferred to have the printed bones in theatre to plan their drill sites and make the transition of the planning to the patient's operation more precise. 3D printing is an innovative use of technology in the use of preoperative planning for complex ear surgery. Surgical planning can be done on the patient's own anatomy which may help to decrease operating time, reduce cost, increase surgical precision and thus reduce complications.
Ebisumoto, Koji; Okami, Kenji; Hamada, Masashi; Maki, Daisuke; Sakai, Akihiro; Saito, Kosuke; Shimizu, Fukuko; Kaneda, Shoji; Iida, Masahiro
2018-06-01
The prognosis of advanced temporal bone cancer is poor, because complete surgical resection is difficult to achieve. Chemoradiotherapy is one of the available curative treatment options; however, its systemic effects on the patient restrict the use of this treatment. A 69-year-old female (who needed peritoneal dialysis) presented at our clinic with T4 left external auditory canal cancer and was treated with cetuximab plus radiotherapy (RT). The primary lesion showed complete response. The patient is currently alive with no evidence of disease two years after completion of the treatment and does not show any late toxicity. This is the first advanced temporal bone cancer patient treated with RT plus cetuximab. Cetuximab plus RT might be a treatment alternative for patients with advanced temporal bone cancer. Copyright © 2017 Elsevier B.V. All rights reserved.
Intra-operative 3D imaging system for robot-assisted fracture manipulation.
Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S
2015-01-01
Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).
Facial nerve stimulation associated with cochlear implant use following temporal bone fractures.
Espahbodi, Mana; Sweeney, Alex D; Lennon, Kristen J; Wanna, George B
2015-01-01
To describe the incidence and management of patients with facial nerve stimulation (FNS) associated with cochlear implant (CI) use in the setting of a prior temporal bone fracture. One adult CI recipient is reported who experienced implant associated FNS with a history of a temporal bone fracture. Additionally, a literature search was performed to identify similar patients from previous descriptions of CI related FNS. Presence of FNS after implantation and ability to modify implant programming to avoid FNS. The patient in the present report experienced FNS for middle and basal electrodes during intraoperative neural response telemetry (NRT) in the absence of any surgical exposure or manipulation of the facial nerve. FNS was absent during device activation, but it recurred during follow-up programming sessions. However, additional programming has prevented further FNS during regular implant use. Four other patients with FNS after temporal bone fracture were identified from the literature, and the present case represents the one of two cases in which reprogramming allowed for implant use without FNS. CI associated FNS is uncommon in patients with a history of a temporal bone fracture, but it is likely that fracture lines provide a lower impedance pathway to the adjacent facial nerve and thus reduce the threshold for FNS. The present report suggests that, in the setting of a prior temporal bone fracture, NRT is not always a reliable predictor of FNS during implant use, and programming changes can help to mitigate FNS when it occurs. Copyright © 2015 Elsevier Inc. All rights reserved.
Pauna, Henrique F.; Monsanto, Rafael C.; Schachern, Patricia A.; Costa, Sady S.; Kwon, Geeyoun; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Objective Endoscopic procedures are becoming common in middle ear surgery. Inflammation due to chronic ear disease can cause bony erosion of the carotid artery and Fallopian canals, making them more vulnerable during surgery. The objective of this study was to determine whether or not chronic ear disease increases dehiscence of the carotid artery and Fallopian canals. Design Comparative human temporal bone study. Setting Otopathology laboratory. Participants We selected 78 temporal bones from 55 deceased donors with chronic otitis media or cholesteatoma, and then compared those 2 groups with a control group of 27 temporal bones from 19 deceased donors with no middle ear disease. Main outcome measures We analyzed the middle ear, carotid artery canal, and Fallopian canal, looking for signs of dehiscence of its bony coverage, using light microscopy. Results We found an increased incidence in dehiscence of the carotid artery and Fallopian canals in temporal bones with chronic middle ear disease. The size of the carotid artery canal dehiscence was larger in the middle ear diseased groups, and its bony coverage, when present, was also thinner compared to the control group. Dehiscence of the carotid artery canal was more frequently located closer to the promontory. The incidence of Fallopian canal dehiscence was significantly higher in temporal bones from donors older than 18 years with chronic middle ear disease. Conclusion The increased incidence of the carotid artery and Fallopian canal dehiscence in temporal bones with chronic middle ear disease elevates the risk of adverse events during middle ear surgery. Level of Evidence N/A. PMID:27455393
Visualization of spatial-temporal data based on 3D virtual scene
NASA Astrophysics Data System (ADS)
Wang, Xianghong; Liu, Jiping; Wang, Yong; Bi, Junfang
2009-10-01
The main purpose of this paper is to realize the expression of the three-dimensional dynamic visualization of spatialtemporal data based on three-dimensional virtual scene, using three-dimensional visualization technology, and combining with GIS so that the people's abilities of cognizing time and space are enhanced and improved by designing dynamic symbol and interactive expression. Using particle systems, three-dimensional simulation, virtual reality and other visual means, we can simulate the situations produced by changing the spatial location and property information of geographical entities over time, then explore and analyze its movement and transformation rules by changing the interactive manner, and also replay history and forecast of future. In this paper, the main research object is the vehicle track and the typhoon path and spatial-temporal data, through three-dimensional dynamic simulation of its track, and realize its timely monitoring its trends and historical track replaying; according to visualization techniques of spatialtemporal data in Three-dimensional virtual scene, providing us with excellent spatial-temporal information cognitive instrument not only can add clarity to show spatial-temporal information of the changes and developments in the situation, but also be used for future development and changes in the prediction and deduction.
Understanding the Adaptive Use of Virtual World Technology Capabilities and Trust in Virtual Teams
ERIC Educational Resources Information Center
Owens, Dawn
2012-01-01
In an environment of global competition and constant technological change, the use of virtual teams has become commonplace for many organizations. Virtual team members are geographically and temporally dispersed, experience cultural diversity, and lack shared social context and face-to-face encounters considered as irreplaceable for building and…
Virtual plate pre-bending for the long bone fracture based on axis pre-alignment.
Liu, Bin; Luo, Xinjian; Huang, Rui; Wan, Chao; Zhang, Bingbing; Hu, Weihua; Yue, Zongge
2014-06-01
In this paper, a modeling and visualizing system for assisting surgeons in correctly registering for the closed fracture reduction surgery is presented. By using this system, the geometric parameters of the target fixation plate before the long bone fracture operation can be obtained. The main processing scheme consists of following steps: firstly (image data process), utilize the Curvelet transform to denoise the CT images of fracture part and then reconstruct the 3D models of the broken bones. Secondly (pre-alignment), extract the axial lines of the broken bones and spatially align them. Then drive the broken bone models to be pre-aligned. Thirdly (mesh segmentation), a method based on vertex normal feature is utilized to obtain the broken bone cross-sections mesh models. Fourthly (fine registration), the ICP (Iterative Closest Point) algorithm is used to register the cross-sections and the broken bone models are driven to achieve the fine registration posture. Lastly (plate fitting), an accurate NURBS surface fitting method is used to construct the virtual plate. The experiment proved that the obtained models of the pre-bended plates were closely bonded to the surface of the registered long bone models. Finally, the lengths, angles and other interested geometric parameters can be measured on the plate models. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, Sungkon; Jang, Seulki; Lee, Sangyeob; Park, Jihoon; Ha, Myungjin; Radfar, Edalat; Jung, Byungjo
2016-03-01
This study investigates the feasibility of an endoscopic laser speckle imaging modality (ELSIM) in the measurement of perfusion of flowing fluid in optical bone tissue phantom(OBTP). Many studies suggested that the change of cochlear blood flow was correlated with auditory disorder. Cochlear microcirculation occurs under the 200μm thickness bone which is the part of the internal structure of the temporal bone. Concern has been raised regarding of getting correct optical signal from hard tissue. In order to determine the possibility of the measurement of cochlear blood flow under bone tissue using the ELSIM, optical tissue phantom (OTP) mimicking optical properties of temporal bone was applied.
Creation of a 3D printed temporal bone model from clinical CT data.
Cohen, Joss; Reyes, Samuel A
2015-01-01
Generate and describe the process of creating a 3D printed, rapid prototype temporal bone model from clinical quality CT images. We describe a technique to create an accurate, alterable, and reproducible rapid prototype temporal bone model using freely available software to segment clinical CT data and generate three different 3D models composed of ABS plastic. Each model was evaluated based on the appearance and size of anatomical structures and response to surgical drilling. Mastoid air cells had retained scaffolding material in the initial versions. This required modifying the model to allow drainage of the scaffolding material. External auditory canal dimensions were similar to those measured from the clinical data. Malleus, incus, oval window, round window, promontory, horizontal semicircular canal, and mastoid segment of the facial nerve canal were identified in all models. The stapes was only partially formed in two models and absent in the third. Qualitative feel of the ABS plastic was softer than bone. The pate produced by drilling was similar to bone dust when appropriate irrigation was used. We present a rapid prototype temporal bone model made based on clinical CT data using 3D printing technology. The model can be made quickly and inexpensively enough to have potential applications for educational training. Copyright © 2015 Elsevier Inc. All rights reserved.
Uematsu, Miho; Tobisawa, Shinsuke; Nagao, Masahiro; Matsubara, Shiro; Mizutani, Toshio; Shibuya, Makoto
2012-01-01
A 50-year-old woman with a history of palmoplantar pustulosis, femur osteomyelitis, and sterno-costo-clavicular hyperostosis presented with a chronic severe left temporal headache that had progressed during the previous year. Her CRP level was elevated. Cranial images showed Gadolinium-enhancement of the left temporal muscle, left parietal bone and dura mater. (99m)Tc-HMDP scintigram showed increased uptake in the left parietal bone, left sterno-costo-clavicular joint, right femoral head and intervertebral joints. Biopsy of the lesion demonstrated 1) proliferation of connective tissue in both perimysium and endomysium of the temporal muscle with mild inflammatory cell infiltration within the interstitium, 2) marked infiltration of granulocytes to the bone marrow of the parietal bone, 3) necrosis and moderate fibrosis in the interstitium with inflammatory cell infiltration in the parietal bone, and 4) moderate fibrosis and slight infiltration of inflammatory cells in the dura mater. The patient was diagnosed with a cranial lesion of synovitis-acne-pustulosis-hyperostosis-osteitis (SAPHO) syndrome. There was a moderate response to treatment with intravenous steroid pulse therapy and subsequent methotrexate. In a case of headache accompanied by inflammatory response, palmoplantar pustulosis and joint lesions such as hyperostosis, the possibility of a rare cranial manifestation of SAPHO syndrome should be considered.
Epitympanum volume and tympanic isthmus area in temporal bones with retraction pockets.
Monsanto, Rafael da Costa; Pauna, Henrique Furlan; Kaya, Serdar; Hızlı, Ömer; Kwon, Geeyoun; Paparella, Michael M; Cureoglu, Sebahattin
2016-11-01
To compare the volume of the epitympanic space, as well as the area of the tympanic isthmus, in human temporal bones with retraction pockets to those with chronic otitis media without retraction pockets and to those with neither condition. Comparative human temporal bone study. We generated a three-dimensional model of the bony epitympanum and measured the epitympanic space. We also compared the area of the tympanic isthmus. The mean total volume of the epitympanum was 40.55 ± 7.14 mm 3 in the retraction pocket group, 50.03 ± 8.49 mm 3 in the chronic otitis media group, and 48.03 ± 9.16 mm 3 in the neither condition group. The mean volume of the anterior, lateral, and medial compartments in temporal bones in the retraction pocket group was significantly smaller than in the two control groups (P < 0.05). Total epitympanic volume was also significantly smaller in the retraction pocket group than in both control groups (P < 0.05). The mean area of the tympanic isthmus was significantly smaller in the retraction pocket group (8.11 ± 2.44 mm 2 ) than in the chronic otitis media group (9.82 ± 2.06 mm 2 ) or the neither condition group (10.66 ± 1.78 mm 2 ) (P < 0.05). Our data indicate that temporal bones with retraction pockets have a smaller volume bony epitympanum and a smaller tympanic isthmus area as compared with temporal bones from both control groups. The smaller volume tympanic isthmus in the retraction pocket group may suggest that a blockage in the aeration pathways to the epitympanum could create dysventilation, resulting in negative pressure and ultimately in retraction pockets and cholesteatomas. NA Laryngoscope, 126:E369-E374, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Intra-temporal facial nerve centerline segmentation for navigated temporal bone surgery
NASA Astrophysics Data System (ADS)
Voormolen, Eduard H. J.; van Stralen, Marijn; Woerdeman, Peter A.; Pluim, Josien P. W.; Noordmans, Herke J.; Regli, Luca; Berkelbach van der Sprenkel, Jan W.; Viergever, Max A.
2011-03-01
Approaches through the temporal bone require surgeons to drill away bone to expose a target skull base lesion while evading vital structures contained within it, such as the sigmoid sinus, jugular bulb, and facial nerve. We hypothesize that an augmented neuronavigation system that continuously calculates the distance to these structures and warns if the surgeon drills too close, will aid in making safe surgical approaches. Contemporary image guidance systems are lacking an automated method to segment the inhomogeneous and complexly curved facial nerve. Therefore, we developed a segmentation method to delineate the intra-temporal facial nerve centerline from clinically available temporal bone CT images semi-automatically. Our method requires the user to provide the start- and end-point of the facial nerve in a patient's CT scan, after which it iteratively matches an active appearance model based on the shape and texture of forty facial nerves. Its performance was evaluated on 20 patients by comparison to our gold standard: manually segmented facial nerve centerlines. Our segmentation method delineates facial nerve centerlines with a maximum error along its whole trajectory of 0.40+/-0.20 mm (mean+/-standard deviation). These results demonstrate that our model-based segmentation method can robustly segment facial nerve centerlines. Next, we can investigate whether integration of this automated facial nerve delineation with a distance calculating neuronavigation interface results in a system that can adequately warn surgeons during temporal bone drilling, and effectively diminishes risks of iatrogenic facial nerve palsy.
Primary aneurysmal bone cyst of coronoid process
Goyal, Amit; Tyagi, Isha; Syal, Rajan; Agrawal, Tanu; Jain, Manoj
2006-01-01
Background Aneurysmal bone cysts are relatively uncommon in the facial skeleton. These usually affect the mandible but origin from the coronoid process is even rarer. To the best of our knowledge, this is the first reported case of a coronoid process aneurysmal bone cyst presenting as temporal fossa swelling. Case presentation A 17 year old boy presented with a progressively increasing swelling in the left temporal region developed over the previous 8 months. An expansile lytic cystic lesion originating from the coronoid process of the left mandible and extending into the infratemporal and temporal fossa regions was found on CT scan. It was removed by a superior approach to the infratemporal fossa. Conclusion Aneurysmal bone cyst of the coronoid process can attain enormous dimensions until the temporal region is also involved. A superior approach to the infratemporal fossa is a reasonable approach for such cases, providing wide exposure and access to all parts of the lesion and ensuring better control and complete excision. PMID:16533409
Chien, Wade; Ravicz, Michael E.; Rosowski, John J.; Merchant, Saumil N.
2008-01-01
Objectives (1) To develop a cadaveric temporal-bone preparation to study the mechanism of hearing loss resulting from superior semicircular canal dehiscence (SCD) and (2) to assess the potential usefulness of clinical measurements of umbo velocity for the diagnosis of SCD. Background The syndrome of dehiscence of the superior semicircular canal is a clinical condition encompassing a variety of vestibular and auditory symptoms, including an air-bone gap at low frequencies. It has been hypothesized that the dehiscence acts as a “third window” into the inner ear that shunts acoustic energy away from the cochlea at low frequencies, causing hearing loss. Methods Sound-induced stapes, umbo, and round-window velocities were measured in prepared temporal bones (n = 8) using laser-Doppler vibrometry (1) with the superior semicircular canal intact, (2) after creation of a dehiscence in the superior canal, and (3) with the dehiscence patched. Clinical measurements of umbo velocity in live SCD ears (n = 29) were compared with similar data from our cadaveric temporal-bone preparations. Results An SCD caused a significant reduction in sound-induced round-window velocity at low frequencies, small but significant increases in sound-induced stapes and umbo velocities, and a measurable fluid velocity inside the dehiscence. The increase in sound-induced umbo velocity in temporal bones was also found to be similar to that measured in the 29 live ears with SCD. Conclusion Findings from the cadaveric temporal-bone preparation were consistent with the third-window hypothesis. In addition, measurement of umbo velocity in live ears is helpful in distinguishing SCD from other otologic pathologies presenting with an air-bone gap (e.g., otosclerosis). PMID:17255894
Reynoso, Exequiel; Capunay, Carlos; Rasumoff, Alejandro; Vallejos, Javier; Carpio, Jimena; Lago, Karen; Carrascosa, Patricia
2016-01-01
The aim of this study was to explore the usefulness of combined virtual monochromatic imaging and metal artifact reduction software (MARS) for the evaluation of musculoskeletal periprosthetic tissue. Measurements were performed in periprosthetic and remote regions in 80 patients using a high-definition scanner. Polychromatic images with and without MARS and virtual monochromatic images were obtained. Periprosthetic polychromatic imaging (PI) showed significant differences compared with remote areas among the 3 tissues explored (P < 0.0001). No significant differences were observed between periprosthetic and remote tissues using monochromatic imaging with MARS (P = 0.053 bone, P = 0.32 soft tissue, and P = 0.13 fat). However, such differences were significant using PI with MARS among bone (P = 0.005) and fat (P = 0.02) tissues. All periprosthetic areas were noninterpretable using PI, compared with 11 (9%) using monochromatic imaging. The combined use of virtual monochromatic imaging and MARS reduced periprosthetic artifacts, achieving attenuation levels comparable to implant-free tissue.
Virtual Surgical Planning: The Pearls and Pitfalls
Efanov, Johnny I.; Roy, Andrée-Anne; Huang, Ke N.
2018-01-01
Objective: Over the past few years, virtual surgical planning (VSP) has evolved into a useful tool for the craniofacial surgeon. Virtual planning and computer-aided design and manufacturing (CAD/CAM) may assist in orthognathic, cranio-orbital, traumatic, and microsurgery of the craniofacial skeleton. Despite its increasing popularity, little emphasis has been placed on the learning curve. Methods: A retrospective analysis of consecutive virtual surgeries was done from July 2012 to October 2016 at the University of Montreal Teaching Hospitals. Orthognathic surgeries and free vascularized bone flap surgeries were included in the analysis. Results: Fifty-four virtual surgeries were done in the time period analyzed. Forty-six orthognathic surgeries and 8 free bone transfers were done. An analysis of errors was done. Eighty-five percentage of the orthognathic virtual plans were adhered to completely, 4% of the plans were abandoned, and 11% were partially adhered to. Seventy-five percentage of the virtual surgeries for free tissue transfers were adhered to, whereas 25% were partially adhered to. The reasons for abandoning the plans were (1) poor communication between surgeon and engineer, (2) poor appreciation for condyle placement on preoperative scans, (3) soft-tissue impedance to bony movement, (4) rapid tumor progression, (5) poor preoperative assessment of anatomy. Conclusion: Virtual surgical planning is a useful tool for craniofacial surgery but has inherent issues that the surgeon must be aware of. With time and experience, these surgical plans can be used as powerful adjuvants to good clinical judgement. PMID:29464146
Kasaven, C P; McIntyre, G T; Mossey, P A
2017-01-01
Our objective was to assess the accuracy of virtual and printed 3-dimensional models derived from cone-beam computed tomographic (CT) scans to measure the volume of alveolar clefts before bone grafting. Fifteen subjects with unilateral cleft lip and palate had i-CAT cone-beam CT scans recorded at 0.2mm voxel and sectioned transversely into slices 0.2mm thick using i-CAT Vision. Volumes of alveolar clefts were calculated using first a validated algorithm; secondly, commercially-available virtual 3-dimensional model software; and finally 3-dimensional printed models, which were scanned with microCT and analysed using 3-dimensional software. For inter-observer reliability, a two-way mixed model intraclass correlation coefficient (ICC) was used to evaluate the reproducibility of identification of the cranial and caudal limits of the clefts among three observers. We used a Friedman test to assess the significance of differences among the methods, and probabilities of less than 0.05 were accepted as significant. Inter-observer reliability was almost perfect (ICC=0.987). There were no significant differences among the three methods. Virtual and printed 3-dimensional models were as precise as the validated computer algorithm in the calculation of volumes of the alveolar cleft before bone grafting, but virtual 3-dimensional models were the most accurate with the smallest 95% CI and, subject to further investigation, could be a useful adjunct in clinical practice. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Temporally coherent 4D video segmentation for teleconferencing
NASA Astrophysics Data System (ADS)
Ehmann, Jana; Guleryuz, Onur G.
2013-09-01
We develop an algorithm for 4-D (RGB+Depth) video segmentation targeting immersive teleconferencing ap- plications on emerging mobile devices. Our algorithm extracts users from their environments and places them onto virtual backgrounds similar to green-screening. The virtual backgrounds increase immersion and interac- tivity, relieving the users of the system from distractions caused by disparate environments. Commodity depth sensors, while providing useful information for segmentation, result in noisy depth maps with a large number of missing depth values. By combining depth and RGB information, our work signi¯cantly improves the other- wise very coarse segmentation. Further imposing temporal coherence yields compositions where the foregrounds seamlessly blend with the virtual backgrounds with minimal °icker and other artifacts. We achieve said improve- ments by correcting the missing information in depth maps before fast RGB-based segmentation, which operates in conjunction with temporal coherence. Simulation results indicate the e±cacy of the proposed system in video conferencing scenarios.
Tuberculous otitis in infants: temporal bone histopathology and clinical extrapolation.
Nicolau, Yamileth; Northrop, Clarinda; Eavey, Roland
2006-08-01
The study of infant temporal bones with tuberculosis (TB) of the middle ear and mastoid could provide information to assist with clinical diagnosis in this population. The TB pandemic has become a critical global public health problem. With the rising incidence of the disease, otolaryngologists might encounter an increased frequency of otologic TB. Pediatric temporal bone reports of TB are rare. Light microscopic examination was performed on both temporal bones from an infant who died as a result of miliary TB. The tympanic membranes were thickened with dilated blood vessels, yet were intact without perforations. Purulence, granulation tissue, and classic tubercles were observed in the middle ears and mastoids. Serous labyrinthitis and inflammatory cells surrounding the Cranial Nerve VIII in the internal auditory canal were observed in the inner ear. The histological findings suggest that a clinical presentation of infantile tuberculous otitis media and mastoiditis could be a patient with otoscopic findings consistent with common otitis media with an intact tympanic membrane, likely in conjunction with inner ear symptoms. Lacking the classic finding of multiple tympanic membrane perforations, tuberculous otitis might be underappreciated in this population.
Tóth, Miklós; Sirirattanapan, Jarinratn; Mann, Wolf
2013-08-01
The purpose of this study is to offer new data about facial nerve malformations in the tympanic cavity. Prospective anatomic study of newborns to demonstrate the submacroscopic anatomy of the intratympanic facial nerve and its surrounding structures by malformations. Step-by-step microdissection of 12 newborn temporal bones and histologic evaluation of 4 middle ears showing multiple malformations. Four of 12 temporal bones presented malformation in the middle ear. All 4 temporal bones showed developmental failures of the stapes, and 3 of them had malposition of the tympanic portion of the facial nerve. In 3 cases, there was an oval window atresia, and in 1 case, the rim of the oval window was not ossified and was positioned medial to the stapes. Malformation or displacement of the stapes can be an indirect sign for facial nerve malformation. The most common site for facial nerve malformation is the tympanic portion. The tympanic segment of the nerve is devoid of bony covering in association with these anomalies of the stapes.
Papercraft temporal bone in the first step of anatomy education.
Hiraumi, Harukazu; Sato, Hiroaki; Ito, Juichi
2017-06-01
(1) To compare temporal bone anatomy comprehension taught to speech therapy students with or without a papercraft model. (2) To explore the effect of papercraft simulation on the understanding of surgical approaches in first-year residents. (1) One-hundred and ten speech therapy students were divided into three classes. The first class was taught with a lecture only. The students in the second class were given a lecture and a papercraft modeling task without instruction. The third class modeled a papercraft with instruction after the lecture. The students were tested on their understanding of temporal bone anatomy. (2) A questionnaire on the understanding of surgical approaches was completed by 10 residents before and after the papercraft modeling. The papercraft models were cut with scissors to simulate surgical approaches. (1) The average scores were 4.4/8 for the first class, 4.3/8 for the second class, and 6.3/8 for the third class. The third class had significantly better results than the other classes (p<0.01, Kruskal-Wallis test). (2) The average scores before and after the papercraft modeling and cutting were 2.6/7 and 4.9/7, respectively. The numerical rating scale score significantly improved (p<0.01, Wilcoxon signed-rank test). The instruction of the anatomy using a papercraft temporal bone model is effective in the first step of learning temporal bone anatomy and surgical approaches. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Rodríguez-Vázquez, José Francisco; Murakami, Gen; Verdugo-López, Samuel; Abe, Shin-ichi; Fujimiya, Mineko
2011-01-01
Closure of the middle ear is believed to be closely related to the evolutionary development of the mammalian jaw. However, few comprehensive descriptions are available on fetal development. We examined paraffin-embedded specimens of 20 mid-term human fetuses at 8–25 weeks of ovulation age (crown-rump length or CRL, 38–220 mm). After 9 weeks, the tympanic bone and the squamous part of the temporal bone, each of which was cranial or caudal to Meckel's cartilage, grew to close the lateral part of the tympanosquamosal fissure. At the same time, the cartilaginous tegmen tympani appeared independently of the petrous part of the temporal bone and resulted in the petrosquamosal fissure. Subsequently, the medial part of the tympanosquamosal fissure was closed by the descent of a cartilaginous inferior process of the tegmen tympani. When Meckel's cartilage changed into the sphenomandibular ligament and the anterior ligament of the malleus, the inferior process of the tegmen tympani interposed between the tympanic bone and the squamous part of the temporal bone, forming the petrotympanic fissure for the chorda tympani nerve and the discomalleolar ligament. Therefore, we hypothesize that, in accordance with the regression of Meckel's cartilage, the rapidly growing temporomandibular joint provided mechanical stress that accelerated the growth and descent of the inferior process of the tegmen tympani via the discomalleolar ligament. The usual diagram showing bony fissures around the tegmen tympani may overestimate the role of the tympanic bone in the fetal middle-ear closure. PMID:21477146
Rasmussen, Sebastian R; Konge, Lars; Mikkelsen, Peter T; Sørensen, Mads S; Andersen, Steven A W
2016-03-01
Cognitive load (CL) theory suggests that working memory can be overloaded in complex learning tasks such as surgical technical skills training, which can impair learning. Valid and feasible methods for estimating the CL in specific learning contexts are necessary before the efficacy of CL-lowering instructional interventions can be established. This study aims to explore secondary task precision for the estimation of CL in virtual reality (VR) surgical simulation and also investigate the effects of CL-modifying factors such as simulator-integrated tutoring and repeated practice. Twenty-four participants were randomized for visual assistance by a simulator-integrated tutor function during the first 5 of 12 repeated mastoidectomy procedures on a VR temporal bone simulator. Secondary task precision was found to be significantly lower during simulation compared with nonsimulation baseline, p < .001. Contrary to expectations, simulator-integrated tutoring and repeated practice did not have an impact on secondary task precision. This finding suggests that even though considerable changes in CL are reflected in secondary task precision, it lacks sensitivity. In contrast, secondary task reaction time could be more sensitive, but requires substantial postprocessing of data. Therefore, future studies on the effect of CL modifying interventions should weigh the pros and cons of the various secondary task measurements. © The Author(s) 2015.
Spatial and temporal aspects of navigation in two neurological patients.
van der Ham, Ineke J M; van Zandvoort, Martine J E; Meilinger, Tobias; Bosch, Sander E; Kant, Neeltje; Postma, Albert
2010-07-14
We present two cases (A.C. and W.J.) with navigation problems resulting from parieto-occipital right hemisphere damage. For both the cases, performance on the neuropsychological tests did not indicate specific impairments in spatial processing, despite severe subjective complaints of spatial disorientation. Various aspects of navigation were tested in a new virtual reality task, the Virtual Tübingen task. A double dissociation between spatial and temporal deficits was found; A.C. was impaired in route ordering, a temporal test, whereas W.J. was impaired in scene recognition and route continuation, which are spatial in nature. These findings offer important insights in the functional and neural architecture of navigation.
Temporal bone fracture following blunt trauma caused by a flying fish.
Goldenberg, D; Karam, M; Danino, J; Flax-Goldenberg, R; Joachims, H Z
1998-10-01
Blunt trauma to the temporal region can cause fracture of the skull base, loss of hearing, vestibular symptoms and otorrhoea. The most common causes of blunt trauma to the ear and surrounding area are motor vehicle accidents, violent encounters, and sports-related accidents. We present an obscure case of a man who was struck in the ear by a flying fish while wading in the sea with resulting temporal bone fracture, sudden deafness, vertigo, cerebrospinal fluid otorrhoea, and pneumocephalus.
Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.
Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T
2016-01-01
This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy.
Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert
This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.
Lee, Hanju; Kanakogi, Yasuhiro; Hiraki, Kazuo
2015-01-01
Animated pedagogical agents are lifelike virtual characters designed to augment learning. A review of developmental psychology literature led to the hypothesis that the temporal contingency of such agents would promote human learning. We developed a Pedagogical Agent with Gaze Interaction (PAGI), an experimental animated pedagogical agent that engages in gaze interaction with students. In this study, university students learned words of a foreign language, with temporally contingent PAGI (live group) or recorded version of PAGI (recorded group), which played pre-recorded sequences from live sessions. The result revealed that students in the live group scored considerably better than those in the recorded group. The finding indicates that incorporating temporal contingency of gaze interaction from a pedagogical agent has positive effect on learning. PMID:26064584
Meeting report of the 2016 bone marrow adiposity meeting.
van der Eerden, Bram; van Wijnen, André
2017-10-02
There is considerable interest in the physiology and pathology, as well as the cellular and molecular biology, of bone marrow adipose tissue (BMAT). Because bone marrow adiposity is linked not only to systemic energy metabolism, but also to both bone marrow and musculoskeletal disorders, this biologic compartment has become of major interest to investigators from diverse disciplines. Bone marrow adiposity represents a virtual multi-tissue endocrine organ, which encompasses cells from multiple developmental lineages (e.g., mesenchymal, myeloid, lymphoid) and occupies all the non-osseous and non-cartilaginous space within long bones. A number of research groups are now focusing on bone marrow adiposity to understand a range of clinical afflictions associated with bone marrow disorders and to consider mechanisms-based strategies for future therapies.
Vehmeijer, Maarten; van Eijnatten, Maureen; Liberton, Niels; Wolff, Jan
2016-08-01
Fractures of the orbital floor are often a result of traffic accidents or interpersonal violence. To date, numerous materials and methods have been used to reconstruct the orbital floor. However, simple and cost-effective 3-dimensional (3D) printing technologies for the treatment of orbital floor fractures are still sought. This study describes a simple, precise, cost-effective method of treating orbital fractures using 3D printing technologies in combination with autologous bone. Enophthalmos and diplopia developed in a 64-year-old female patient with an orbital floor fracture. A virtual 3D model of the fracture site was generated from computed tomography images of the patient. The fracture was virtually closed using spline interpolation. Furthermore, a virtual individualized mold of the defect site was created, which was manufactured using an inkjet printer. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. The sculptured autologous orbital floor implant showed an excellent fit in vivo. The combination of virtual planning and 3D printing offers an accurate and cost-effective treatment method for orbital floor fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Virtual Environments as a Tool for Improving Sequence Ability of Deaf and Hard of Hearing Children
ERIC Educational Resources Information Center
Eden, Sigal; Ingber, Sara
2014-01-01
The study examined the efficacy of an early intervention program to improve children's sequential time perception through virtual versus pictorial training in arranging episodes of temporal scripts. The researchers examined 65 deaf and hard of hearing children ages 4-7 years who were divided into two groups: (a) virtual environments technological…
Kün-Darbois, Jean-Daniel; Libouban, Hélène; Chappard, Daniel
2015-08-01
In man, botulinum toxin type A (BTX) is injected in masticatory muscles for several indications such as trismus, bruxism, or masseter hypertrophy. Bone changes in the mandible following BTX injections in adult animal have therefore became a subject of interest. The aim of this study was to analyze condylar and alveolar bone changes following BTX unilateral injections in masseter and temporal muscles in adult rats. Mature male rats (n = 15) were randomized into 2 groups: control (CTRL; n = 6) and BTX group (n= 9). Rats of the BTX group received a single injection of BTX into right masseter and temporal muscles. Rats of the CTRL group were similarly injected with saline solution. Rats were sacrificed 4 weeks after injections. Masticatory muscles examination and microcomputed tomography (microCT) were performed. A significant difference of weight was found between the 2 groups at weeks 2, 3 and 4 (p < 0.05). Atrophy of the right masseter and temporal muscles was observed in all BTX rats. MicroCT analysis showed significant bone loss in the right alveolar and condylar areas in BTX rats. Decrease in bone volume reached -20% for right alveolar bone and -35% for right condylar bone. A hypertrophic bone metaplasia at the digastric muscle enthesis was found on every right hemimandible in the BTX group and none in the CTRL group. BTX injection in masticatory muscles leads to a significant and major mandible bone loss. These alterations can represent a risk factor for fractures in human. The occurrence of a hypertrophic bone metaplasia at the Mus Digastricus enthesis may constitute an etiological factor for tori. Copyright © 2015 Elsevier Inc. All rights reserved.
He, Jingzhen; Zu, Yuliang; Wang, Qing; Ma, Xiangxing
2014-12-01
The purpose of this study was to determine the performance of low-dose computed tomography (CT) scanning with integrated circuit (IC) detector in defining fine structures of temporal bone in children by comparing with the conventional detector. The study was performed with the approval of our institutional review board and the patients' anonymity was maintained. A total of 86 children<3 years of age underwent imaging of temporal bone with low-dose CT (80 kV/150 mAs) equipped with either IC detector or conventional discrete circuit (DC) detector. The image noise was measured for quantitative analysis. Thirty-five structures of temporal bone were further assessed and rated by 2 radiologists for qualitative analysis. κ Statistics were performed to determine the agreement reached between the 2 radiologists on each image. Mann-Whitney U test was used to determine the difference in image quality between the 2 detector systems. Objective analysis showed that the image noise was significantly lower (P<0.001) with the IC detector than with the DC detector. The κ values for qualitative assessment of the 35 fine anatomical structures revealed high interobserver agreement. The delineation for 30 of the 35 landmarks (86%) with the IC detector was superior to that with the conventional DC detector (P<0.05) although there were no differences in the delineation of the remaining 5 structures (P>0.05). The low-dose CT images acquired with the IC detector provide better depiction of fine osseous structures of temporal bone than that with the conventional DC detector.
Treatment outcomes of temporal bone osteoradionecrosis.
Kammeijer, Quinten; van Spronsen, Erik; Mirck, Piet G B; Dreschler, Wouter A
2015-04-01
To investigate the clinical relevance of the classification systems used for temporal bone osteoradionecrosis (ORN) and to define a treatment protocol for temporal bone ORN. Retrospective case series. Amsterdam, department of otorhinolaryngology and head and neck surgery. Classification of temporal bone ORN was performed through use of clinical data and radiologic imaging. Outcomes of conservative and surgical treatment were investigated and compared for different grades of ORN. Of the 49 ears included in this study, 35 were primarily treated conservatively. At start of conservative treatment, 23 were classified as a localized and 8 as a diffuse form of ORN; 4 could not be classified. There was a significant difference in clinical outcome between the localized and diffuse forms of ORN (χ(2) = 5.862, P = .015), and mastoid air cell destruction on preoperative computed tomography scan was found to be a significant predictor for a negative outcome of conservative treatment (χ(2) = 4.34, P = .037). Fourteen ears with diffuse ORN were primarily treated surgically, and 11 were secondarily treated surgically following a period of conservative treatment. Twenty-two patients were treated with subtotal petrosectomy, of which 20 were cured. Three patients were treated with canal wall down mastoidectomy, and 2 had recurrence of disease. Ramsden's classification system is clinically relevant in predicting conservative treatment outcomes. Mastoid air cell destruction on computed tomography differentiates between the localized and diffuse forms of ORN. Given our results and experience with treating temporal bone ORN, we propose a treatment protocol. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Sun, S P; Lu, W; Lei, Y B; Men, X M; Zuo, B; Ding, S G
2017-08-07
Objective: To discuss the prediction of round window(RW) visibility in cochlear implantation(CI) with temporal bone high resolution computed tomography(HRCT). Methods: From January 2013 to January 2017, 130 cases underwent both HRCT and CI in our hospital were analyzed. The distance from facial nerve to posterior canal wall(FWD), the angle between facial nerve and inner margin of round window(FRA), and the angle between facial nerve and tympanic anulus to inner margin of round window(FRAA) were detected at the level of round window on axial temporal bone HRCT. A line parallel to the posterior wall of ear canal was drawn from the anterior wall of facial nerve at the level of round window on axial temporal bone HRCT and its relationship with round window was detected (facial-round window line, FRL): type0-posterior to the round window, type1-between the round window, type2-anterior to the round window. Their(FWD, FRA, FRAA, FRL) relationships with intra-operative round window visibility were analyzed by SPSS 17.0 software. Results: FWD( F =18.76, P =0.00), FRA( F =34.57, P =0.00), FRAA ( F =14.24, P =0.00) could affect the intra-operative RW visibility significantly. RW could be exposed completely during CI when preoperative HRCT showing type0 FRL. RW might be partly exposed and not exposed when preoperative HRCT showing type1 and type2 FRL respectively. Conclusion: FWD, FRA, FRAA and FRL of temporal bone HRCT can predict intra-operative round window visibility effectively in CI surgery.
Matsumoto, K; Akagi, K; Abekura, M; Ohkawa, M; Tasaki, O; Tomishima, T
2001-04-01
Cosmetic deformities that appear following pterional craniotomy are usually caused by temporal muscle atrophy, injury to the frontotemporal branch of the facial nerve, or bone pits in the craniotomy line. To resolve these problems during pterional craniotomy, an alternative method was developed in which a split myofascial bone flap and a free bone flap are used. The authors have used this method in the treatment of 40 patients over the last 3 years. Excellent cosmetic and functional results have been obtained. This method can provide wide exposure similar to that achieved using Yaşargil's interfascial pterional craniotomy, without limiting the operative field with a bulky temporal muscle flap.
Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F
2004-03-01
Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.
The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures
Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian
2017-01-01
Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875
In-home virtual reality videogame telerehabilitation in adolescents with hemiplegic cerebral palsy.
Golomb, Meredith R; McDonald, Brenna C; Warden, Stuart J; Yonkman, Janell; Saykin, Andrew J; Shirley, Bridget; Huber, Meghan; Rabin, Bryan; Abdelbaky, Moustafa; Nwosu, Michelle E; Barkat-Masih, Monica; Burdea, Grigore C
2010-01-01
Golomb MR, McDonald BC, Warden SJ, Yonkman J, Saykin AJ, Shirley B, Huber M, Rabin B, AbdelBaky M, Nwosu ME, Barkat-Masih M, Burdea GC. In-home virtual reality videogame telerehabilitation in adolescents with hemiplegic cerebral palsy. To investigate whether in-home remotely monitored virtual reality videogame-based telerehabilitation in adolescents with hemiplegic cerebral palsy can improve hand function and forearm bone health, and demonstrate alterations in motor circuitry activation. A 3-month proof-of-concept pilot study. Virtual reality videogame-based rehabilitation systems were installed in the homes of 3 participants and networked via secure Internet connections to the collaborating engineering school and children's hospital. Adolescents (N=3) with severe hemiplegic cerebral palsy. Participants were asked to exercise the plegic hand 30 minutes a day, 5 days a week using a sensor glove fitted to the plegic hand and attached to a remotely monitored videogame console installed in their home. Games were custom developed, focused on finger movement, and included a screen avatar of the hand. Standardized occupational therapy assessments, remote assessment of finger range of motion (ROM) based on sensor glove readings, assessment of plegic forearm bone health with dual-energy x-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT), and functional magnetic resonance imaging (fMRI) of hand grip task. All 3 adolescents showed improved function of the plegic hand on occupational therapy testing, including increased ability to lift objects, and improved finger ROM based on remote measurements. The 2 adolescents who were most compliant showed improvements in radial bone mineral content and area in the plegic arm. For all 3 adolescents, fMRI during grip task contrasting the plegic and nonplegic hand showed expanded spatial extent of activation at posttreatment relative to baseline in brain motor circuitry (eg, primary motor cortex and cerebellum). Use of remotely monitored virtual reality videogame telerehabilitation appears to produce improved hand function and forearm bone health (as measured by DXA and pQCT) in adolescents with chronic disability who practice regularly. Improved hand function appears to be reflected in functional brain changes. Copyright (c) 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
The sense of body ownership relaxes temporal constraints for multisensory integration.
Maselli, Antonella; Kilteni, Konstantina; López-Moliner, Joan; Slater, Mel
2016-08-03
Experimental work on body ownership illusions showed how simple multisensory manipulation can generate the illusory experience of an artificial limb as being part of the own-body. This work highlighted how own-body perception relies on a plastic brain representation emerging from multisensory integration. The flexibility of this representation is reflected in the short-term modulations of physiological states and perceptual processing observed during these illusions. Here, we explore the impact of ownership illusions on the temporal dimension of multisensory integration. We show that, during the illusion, the temporal window for integrating touch on the physical body with touch seen on a virtual body representation, increases with respect to integration with visual events seen close but separated from the virtual body. We show that this effect is mediated by the ownership illusion. Crucially, the temporal window for visuotactile integration was positively correlated with participants' scores rating the illusory experience of owning the virtual body and touching the object seen in contact with it. Our results corroborate the recently proposed causal inference mechanism for illusory body ownership. As a novelty, they show that the ensuing illusory causal binding between stimuli from the real and fake body relaxes constraints for the integration of bodily signals.
Augmented virtuality for arthroscopic knee surgery.
Li, John M; Bardana, Davide D; Stewart, A James
2011-01-01
This paper describes a computer system to visualize the location and alignment of an arthroscope using augmented virtuality. A 3D computer model of the patient's joint (from CT) is shown, along with a model of the tracked arthroscopic probe and the projection of the camera image onto the virtual joint. A user study, using plastic bones instead of live patients, was made to determine the effectiveness of this navigated display; the study showed that the navigated display improves target localization in novice residents.
Temporal bone radiography using the orthopantomograph
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatezawa, T.
1981-09-01
Temporal bone radiographs obtained with an Orthopantomograph were compared with conventional radiographs. In acoustic neurinoma, cholesteatoma, otitis media, and middle fossa tumors, both methods demonstrated the abnormalities well. In two cases with lesions extending beyond the range of conventional projections, the broad orthopantomographic coverage was very valuable. Mastoid air cells, the mastoid process, petrous ridge, and internal auditory meatus were well demonstrated by both techniques. Orthopantomography was found to be superior in the demonstration of the petrous apex, while the superior semicircular canal was better demonstrated on the conventional views. Bilateral symmetry was particularly good and because of fewer films,more » radiation exposure was considerably less with orthopantomography. For many applications, orthopantomography is an adequate convenient substitute for conventional methods of examining the temporal bones.« less
Meeting report of the 2016 bone marrow adiposity meeting
van der Eerden, Bram; van Wijnen, André
2017-01-01
Abstract There is considerable interest in the physiology and pathology, as well as the cellular and molecular biology, of bone marrow adipose tissue (BMAT). Because bone marrow adiposity is linked not only to systemic energy metabolism, but also to both bone marrow and musculoskeletal disorders, this biologic compartment has become of major interest to investigators from diverse disciplines. Bone marrow adiposity represents a virtual multi-tissue endocrine organ, which encompasses cells from multiple developmental lineages (e.g., mesenchymal, myeloid, lymphoid) and occupies all the non-osseous and non-cartilaginous space within long bones. A number of research groups are now focusing on bone marrow adiposity to understand a range of clinical afflictions associated with bone marrow disorders and to consider mechanisms-based strategies for future therapies. PMID:28410005
Mathematical model of bone drilling for virtual surgery system
NASA Astrophysics Data System (ADS)
Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.
2018-04-01
The bone drilling is an essential part of surgeries in ENT and Dentistry. A proper training of drilling machine handling skills is impossible without proper modelling of the drilling process. Utilization of high precision methods like FEM is limited due to the requirement of 1000 Hz update rate for haptic feedback. The study presents a mathematical model of the drilling process that accounts the properties of materials, the geometry and the rotation rate of a burr to compute the removed material volume. The simplicity of the model allows for integrating it in the high-frequency haptic thread. The precision of the model is enough for a virtual surgery system targeted on the training of the basic surgery skills.
Kim, Chang Rae; Jeon, Ji Young
2018-05-01
The purpose of this article is to compare radiation doses and conspicuity of anatomic landmarks of the temporal bone between the CT technique using spectral beam shaping at 150 kVp with a dedicated tin filter (150 kVp-Sn) and the conventional protocol at 120 kVp. 25 patients (mean age, 46.8 ± 21.2 years) were examined using the 150-kVp Sn protocol (200 reference mAs using automated tube current modulation, 64 × 0.6 mm collimation, 0.6 mm slice thickness, pitch 0.8), whereas 30 patients (mean age, 54.5 ± 17.8 years) underwent the 120-kVp protocol (180 mAs, 128 × 0.6 mm collimation, 0.6 mm slice thickness, pitch 0.8). Radiation doses were compared between the two acquisition techniques, and dosimetric data from the literature were reviewed for comparison of radiation dose reduction. Subjective conspicuity of 23 anatomic landmarks of the temporal bone, expressed by 5-point rating scale and objective conspicuity by signal-to-noise ratio (SNR) which measured in 4 different regions of interest (ROI), were compared between 150-kVp Sn and 120-kVp acquisitions. The mean dose-length-product (DLP) and effective dose were significantly lower for the 150-kVp Sn scans (0.26 ± 0.26 mSv) compared with the 120-kVp scans (0.92 ± 0.10 mSv, p < 0.001). The lowest effective dose from the literature-based protocols was 0.31 ± 0.12 mSv, which proposed as a low-dose protocol in the setting of spiral multislice temporal bone CT. SNR was slightly superior for 120-kVp images, however analyzability of the 23 anatomic structures did not differ significantly between 150-kVp Sn and 120-kVp scans. Temporal bone CT performed at 150 kVp with an additional tin filter for spectral shaping markedly reduced radiation exposure when compared with conventional temporal bone CT at 120 kVp while maintaining anatomic conspicuity. The decreased radiation dose of the 150-kVp Sn was also lower in comparison to the previous literature-based low-dose temporal bone CT protocol. Copyright © 2018 Elsevier B.V. All rights reserved.
Colman, Kerri L; Dobbe, Johannes G G; Stull, Kyra E; Ruijter, Jan M; Oostra, Roelof-Jan; van Rijn, Rick R; van der Merwe, Alie E; de Boer, Hans H; Streekstra, Geert J
2017-07-01
Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.
Cornips, Erwin M J; Cox, Kimberly E M; Creytens, David H K V; Granzen, Bernd; Weber, Jacobiene W; Ter Laak-Poort, Mariel P
2009-12-01
Juvenile xanthogranuloma (JXG) is a rare histiocytic disorder primarily observed during the first 2 years of life. Most patients present with a solitary cutaneous lesion; however, others present with extracutaneous manifestations or even with systemic involvement. The authors describe a 2-month-old boy in whom was diagnosed a unifocal extracutaneous JXG involving the temporal bone. Unlike 3 other cases of solitary JXGs of the temporal bone in the literature, the present case involved destruction of the dura mater and leptomeningeal enhancement surrounding the entire temporal lobe. The lesion did not regress after an initial biopsy procedure and had to be removed more radically because of progressive mass effect on the brain. The child recently underwent a reconstructive skull procedure and is doing well almost 2 years postoperatively without evidence of disease. This case demonstrates that even in instances of extensive disease a favorable outcome is possible without chemotherapy.
Poganiatz, I; Wagner, H
2001-04-01
Interaural level differences play an important role for elevational sound localization in barn owls. The changes of this cue with sound location are complex and frequency dependent. We exploited the opportunities offered by the virtual space technique to investigate the behavioral relevance of the overall interaural level difference by fixing this parameter in virtual stimuli to a constant value or introducing additional broadband level differences to normal virtual stimuli. Frequency-specific monaural cues in the stimuli were not manipulated. We observed an influence of the broadband interaural level differences on elevational, but not on azimuthal sound localization. Since results obtained with our manipulations explained only part of the variance in elevational turning angle, we conclude that frequency-specific cues are also important. The behavioral consequences of changes of the overall interaural level difference in a virtual sound depended on the combined interaural time difference contained in the stimulus, indicating an indirect influence of temporal cues on elevational sound localization as well. Thus, elevational sound localization is influenced by a combination of many spatial cues including frequency-dependent and temporal features.
Constructing Social Networks from Unstructured Group Dialog in Virtual Worlds
NASA Astrophysics Data System (ADS)
Shah, Fahad; Sukthankar, Gita
Virtual worlds and massively multi-player online games are rich sources of information about large-scale teams and groups, offering the tantalizing possibility of harvesting data about group formation, social networks, and network evolution. However these environments lack many of the cues that facilitate natural language processing in other conversational settings and different types of social media. Public chat data often features players who speak simultaneously, use jargon and emoticons, and only erratically adhere to conversational norms. In this paper, we present techniques for inferring the existence of social links from unstructured conversational data collected from groups of participants in the Second Life virtual world. We present an algorithm for addressing this problem, Shallow Semantic Temporal Overlap (SSTO), that combines temporal and language information to create directional links between participants, and a second approach that relies on temporal overlap alone to create undirected links between participants. Relying on temporal overlap is noisy, resulting in a low precision and networks with many extraneous links. In this paper, we demonstrate that we can ameliorate this problem by using network modularity optimization to perform community detection in the noisy networks and severing cross-community links. Although using the content of the communications still results in the best performance, community detection is effective as a noise reduction technique for eliminating the extra links created by temporal overlap alone.
Schachern, Patricia A; Kwon, Geeyoun; Briles, David E; Ferrieri, Patricia; Juhn, Steven; Cureoglu, Sebahattin; Paparella, Michael M; Tsuprun, Vladimir
2017-10-01
Bacterial resistance in acute otitis can result in bacterial persistence and biofilm formation, triggering chronic and recurrent infections. To investigate the middle ear inflammatory response to bacterial infection in human and chinchilla temporal bones. Six chinchillas underwent intrabullar inoculations with 0.5 mL of 106 colony-forming units (CFUs) of Streptococcus pneumoniae, serotype 2. Two days later, we counted bacteria in middle ear effusions postmortem. One ear from each chinchilla was processed in paraffin and sectioned at 5 µm. The opposite ear was embedded in epoxy resin, sectioned at a thickness of 1 µm, and stained with toluidine blue. In addition, we examined human temporal bones from 2 deceased donors with clinical histories of otitis media (1 with acute onset otitis media, 1 with recurrent infection). Temporal bones had been previously removed at autopsy, processed, embedded in celloidin, and cut at a thickness of 20 µm. Sections of temporal bones from both chinchillas and humans were stained with hematoxylin-eosin and immunolabeled with antifibrin and antihistone H4 antibodies. Histopatological and imminohistochemical changes owing to otitis media. Bacterial counts in chinchilla middle ear effusions 2 days after inoculation were approximately 2 logs above initial inoculum counts. Both human and chinchilla middle ear effusions contained bacteria embedded in a fibrous matrix. Some fibers in the matrix showed positive staining with antifibrin antibody, others with antihistone H4 antibody. In acute and recurrent otitis media, fibrin and neutrophil extracellular traps (NETs) are part of the host inflammatory response to bacterial infection. In the early stages of otitis media the host defense system uses fibrin to entrap bacteria, and NETs function to eliminate bacteria. In chronic otitis media, fibrin and NETs appear to persist.
Meyer, Mathias; Haubenreisser, Holger; Raupach, Rainer; Schmidt, Bernhard; Lietzmann, Florian; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Schad, Lothar R; Schoenberg, Stefan O; Henzler, Thomas
2015-01-01
To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm(2) removes the necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63%/39% lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50% • A smaller focal spot of 0.2 mm (2) significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear.
Carlson, Matthew L; Sweeney, Alex D; Modest, Mara C; Van Gompel, Jamie J; Haynes, David S; Neff, Brian A
2015-11-01
Inverting papillomas (IPs) are benign locally invasive tumors that most commonly present within the sinonasal cavity. Temporal bone involvement is exceedingly rare, with fewer than 30 cases reported within the English literature to date. Case series and systematic review of the literature. Four consecutive subjects with temporal bone inverting papilloma (TBIP) were treated, and an additional 28 previously published cases were identified in the literature. Main outcome measures were disease presentation, diagnostic evaluation, management strategy, and outcome. A total of 32 cases were analyzed. The median age at diagnosis was 54 years (mean 54.1; range 19-81 years). Nineteen (59%) patients had synchronous or metachronous sinonasal IP, whereas 13 (41%) had isolated temporal bone disease without sinus involvement. Over half of the patients undergoing microsurgical resection experienced at least one recurrence. Compared to patients with a history of sinus IP, subjects with primary TBIP were younger at time of presentation (44 vs. 58 years; P=0.012); were more commonly female (62% vs. 32%; P=0.15); and were less likely to have intracranial spread (8% vs. 26%; P=0.36), cranial neuropathy (8% vs. 26%; P=0.36), human papillomavirus positivity (11% vs. 57%; P=0.11), or associated carcinoma (0% vs. 47%; P=0.004). Inverting papilloma of the lateral skull base is rare and can pose a significant therapeutic challenge. Primary lesions of the temporal bone appear to follow a less aggressive clinical course when compared to those arising in association with sinonasal disease. Gross total resection is the preferred method of treatment, when feasible, given the high rate of recurrence with subtotal resection and risk of associated malignancy. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Mantokoudis, Georgios; Huth, Markus E; Weisstanner, Christian; Friedrich, Hergen M; Nauer, Claude; Candreia, Claudia; Caversaccio, Marco D; Senn, Pascal
2016-01-01
The preservation of residual hearing in cochlear implantation opens the door for optimal functional results. This atraumatic surgical technique requires training; however, the traditional human cadaveric temporal bones have become less available or unattainable in some institutions. This study investigates the suitability of an alternative model, using cadaveric lamb temporal bone, for surgical training of atraumatic round window electrode insertion. A total of 14 lamb temporal bones were dissected for cochlear implantation by four surgeons. After mastoidectomy, visualization, and drilling of the round window niche, an atraumatic round window insertion of a Medel Flex24 electrode was performed. Electrode insertion depth and position were verified by computed tomography scans. All cochleas were successfully implanted using the atraumatic round window approach; however, surgical access through the mastoid was substantially different when compared human anatomy. The mean number of intracochlear electrode contacts was 6.5 (range, 4-11) and the mean insertion depth 10.4 mm (range, 4-20 mm), which corresponds to a mean angular perimodiolar insertion depth of 229 degrees (range 67-540°). Full insertion of the electrode was not possible because of the smaller size of the lamb cochlea in comparison to that of the human. The lamb temporal bone model is well suited as a training model for atraumatic cochlear implantation at the level of the round window. The minimally pneumatized mastoid as well as the smaller cochlea can help prepare a surgeon for difficult cochlear implantations. Because of substantial differences to human anatomy, it is not an adequate training model for other surgical techniques such as mastoidectomy and posterior tympanotomy as well as full electrode insertion.
Pediatric Temporal Bone Fractures: A 10-Year Experience.
Wexler, Sonya; Poletto, Erica; Chennupati, Sri Kiran
2017-11-01
The aim of the study was to compare the traditional and newer temporal bone fracture classification systems and their reliability in predicting serious outcomes of hearing loss and facial nerve (FN) injury. We queried the medical record database for hospital visits from 2002 to 2013 related to the search term temporal. A total of 1144 records were identified, and of these, 46 records with documented temporal bone fractures were reviewed for patient age, etiology and classification of the temporal bone fracture, FN examination, and hearing status. Of these records, radiology images were available for 38 patients and 40 fractures. Thirty-eight patients with accessible radiologic studies, aged 10 months to 16 years, were identified as having 40 temporal bone fractures for which the otolaryngology service was consulted. Twenty fractures (50.0%) were classified as longitudinal, 5 (12.5%) as transverse, and 15 (37.5%) as mixed. Using the otic capsule sparing (OCS)/violating nomenclature, 32 (80.0%) of fractures were classified as OCS, 2 (5.0%) otic capsule violating (OCV), and 6 (15.0%) could not be classified using this system. The otic capsule was involved in 1 (5%) of the longitudinal fractures, none of the transverse fractures, and 1 (6.7%) of the mixed fractures. Sensorineural hearing loss was found in only 2 fractures (5.0%) and conductive hearing loss (CHL) in 6 fractures (15.0%). Two fractures (5.0%) had ipsilateral facial palsy but no visualized fracture through the course of the FN canal. Neither the longitudinal/transverse/mixed nor OCS/OCV classifications were predictors of sensorineural hearing loss (SNHL), CHL, or FN involvement by Fisher exact statistical analysis (for SNHL: P = 0.37 vs 0.16; for CHL: P = 0.71 vs 0.33; for FN: P = 0.62 vs 0.94, respectively). In this large pediatric series, neither classification system of longitudinal/transverse/mixed nor OCS/OCV was predictive of SNHL, CHL, or FN palsy. A more robust database of audiologic results would be helpful in demonstrating this relationship.
Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar
2016-02-01
Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.
Chen, Wen-Jing; Ye, Jing-Ying; Li, Xin; Xu, Jia; Yi, Hai-Jin
2017-08-23
This study aims to discuss clinical characteristics, image manifestation and treatment methods of temporal bone lesions with facial paralysis as the main manifestation for deepening the understanding of such type of lesions and reducing erroneous and missed diagnosis. The clinical data of 16 patients with temporal bone lesions and facial paralysis as main manifestation, who were diagnosed and treated from 2009 to 2016, were retrospectively analyzed. Among these patients, six patients had congenital petrous bone cholesteatoma (PBC), nine patients had facial nerve schwannoma, and one patient had facial nerve hemangioma. All the patients had an experience of long-term erroneous diagnosis. The lesions were completely excised by surgery. PBC and primary facial nerve tumors were pathologically confirmed. Facial-hypoglossal nerve anastomosis was performed on two patients. HB grade VI was recovered to HB grade V in one patient. The anastomosis failed due to severe facial nerve fibrosis in one patient. Hence, HB remained at grade VI. Postoperative recovery was good for all patients. No lesion recurrence was observed after 1-6 years of follow-up. For the patients with progressive or complete facial paralysis, imaging examination should be perfected in a timely manner. Furthermore, PBC, primary facial nerve tumors and other temporal bone space-occupying lesions should be eliminated. Lesions should be timely detected and proper intervention should be conducted, in order to reduce operation difficulty and complications, and increase the opportunity of facial nerve function reconstruction.
Dedouit, Fabrice; Saint-Martin, Pauline; Mokrane, Fatima-Zohra; Savall, Frédéric; Rousseau, Hervé; Crubézy, Eric; Rougé, Daniel; Telmon, Norbert
2015-09-01
Virtual anthropology consists of the introduction of modern slice imaging to biological and forensic anthropology. Thanks to this non-invasive scientific revolution, some classifications and staging systems, first based on dry bone analysis, can be applied to cadavers with no need for specific preparation, as well as to living persons. Estimation of bone and dental age is one of the possibilities offered by radiology. Biological age can be estimated in clinical forensic medicine as well as in living persons. Virtual anthropology may also help the forensic pathologist to estimate a deceased person's age at death, which together with sex, geographical origin and stature, is one of the important features determining a biological profile used in reconstructive identification. For this forensic purpose, the radiological tools used are multislice computed tomography and, more recently, X-ray free imaging techniques such as magnetic resonance imaging and ultrasound investigations. We present and discuss the value of these investigations for age estimation in anthropology.
Al-Ardah, Aladdin; Alqahtani, Nasser; AlHelal, Abdulaziz; Goodacre, Brian; Swamidass, Rajesh; Garbacea, Antoanela; Lozada, Jaime
2018-05-02
This technique describes a novel approach for planning and augmenting a large bony defect using a titanium mesh (TiMe). A 3-dimensional (3D) surgical model was virtually created from a cone beam computed tomography (CBCT) and wax-pattern of the final prosthetic outcome. The required bone volume (horizontally and vertically) was digitally augmented and then 3D printed to create a bone model. The 3D model was then used to contour the TiMe in accordance with the digital augmentation. With the contoured / preformed TiMe on the 3D printed model a positioning jig was made to aid the placement of the TiMe as planned during surgery. Although this technique does not impact the final outcome of the augmentation procedure, it allows the clinician to virtually design the augmentation, preform and contour the TiMe, and create a positioning jig reducing surgical time and error.
A metastatic glomus jugulare tumor. A temporal bone report
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Fiky, F.M.; Paparella, M.M.
The clinicopathologic findings in the temporal bone of a patient with a highly malignant metastasizing glomus jugulare tumor are reported. The patient exhibited all the symptoms of primary malignant tumors of the ear, including facial paralysis, otorrhea, pain, hearing loss, tinnitus, dizziness, and vertigo. He was treated with cobalt irradiation followed by radium implant in the ear canal for a residual tumor; then a left-sided radical mastoidectomy was performed.
Scheinpflug, L; Vorwerk, U; Begall, K
1995-01-01
By means of a model of the external and the middle ear it is possible to simulate various, exactly defined pathological conditions of the middle ear and to describe their influence on ear canal resonance. Starting point of the investigations are fresh postmortem preparations of 8 human temporal bones with an intact ear drum and a retained skin of the ear canal. The compliance of the middle ear does not significantly differ from the clinical data of probands with healthy ears. After antrotomy it is possible to simulate pathological conditions of the middle ear one after the other at the same temporal bone. The influence of the changed middle ear conditions on ear drum compliance, ear canal volume and on the resonance curve of the external ear canal was investigated. For example, the middle ear was filled with water to create approximately the same conditions as in acute serous otitis media. In this middle ear condition a significant increase of the sound pressure amplification was found, on an average by 4 decibels compared to the unchanged temporal bone model. A small increase in resonance frequency was also measured. The advantages of this model are the approximately physiological conditions and the constant dimensions of the external and middle ear.
A high-resolution imaging technique using a whole-body, research photon counting detector CT system
NASA Astrophysics Data System (ADS)
Leng, S.; Yu, Z.; Halaweish, A.; Kappler, S.; Hahn, K.; Henning, A.; Li, Z.; Lane, J.; Levin, D. L.; Jorgensen, S.; Ritman, E.; McCollough, C.
2016-03-01
A high-resolution (HR) data collection mode has been introduced to a whole-body, research photon-counting-detector CT system installed in our laboratory. In this mode, 64 rows of 0.45 mm x 0.45 mm detector pixels were used, which corresponded to a pixel size of 0.25 mm x 0.25 mm at the iso-center. Spatial resolution of this HR mode was quantified by measuring the MTF from a scan of a 50 micron wire phantom. An anthropomorphic lung phantom, cadaveric swine lung, temporal bone and heart specimens were scanned using the HR mode, and image quality was subjectively assessed by two experienced radiologists. High spatial resolution of the HR mode was evidenced by the MTF measurement, with 15 lp/cm and 20 lp/cm at 10% and 2% modulation. Images from anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures, such as lung vessels, lung nodules, temporal bone structures, and coronary arteries. Temporal bone images showed critical anatomy (i.e. stapes superstructure) that was clearly visible in the PCD system. These results demonstrated the potential application of this imaging mode in lung, temporal bone, and vascular imaging. Other clinical applications that require high spatial resolution, such as musculoskeletal imaging, may also benefit from this high resolution mode.
Inner ear changes in mucopolysaccharidosis type I/Hurler syndrome.
Kariya, Shin; Schachern, Patricia A; Nishizaki, Kazunori; Paparella, Michael M; Cureoglu, Sebahattin
2012-10-01
Mucopolysaccharidosis type I/Hurler syndrome is an autosomal recessive disease caused by a deficiency of α-L-iduronidase activity. Recurrent middle ear infections and hearing loss are common complications in Hurler syndrome. Although sensorineural and conductive components occur, the mechanism of sensorineural hearing loss has not been determined. The purpose of this study is to evaluate the quantitative inner ear histopathology of the temporal bones of patients with Hurler syndrome. Eleven temporal bones from 6 patients with Hurler syndrome were examined. Age-matched healthy control samples consisted of 14 temporal bones from 7 cases. Temporal bones were serially sectioned in the horizontal plane and stained with hematoxylin and eosin. The number of spiral ganglion cells, loss of cochlear hair cells, area of stria vascularis, and cell density of spiral ligament were evaluated using light microscopy. There was no significant difference between Hurler syndrome and healthy controls in the number of spiral ganglion cells, area of stria vascularis, or cell density of spiral ligament. The number of cochlear hair cells in Hurler syndrome was significantly decreased compared with healthy controls. Auditory pathophysiology in the central nerve system in Hurler syndrome remains unknown; however, decreased cochlear hair cells may be one of the important factors for the sensorineural component of hearing loss.
Variability of the temporal bone surface's topography: implications for otologic surgery
NASA Astrophysics Data System (ADS)
Lecoeur, Jérémy; Noble, Jack H.; Balachandran, Ramya; Labadie, Robert F.; Dawant, Benoit M.
2012-02-01
Otologic surgery is performed for a variety of reasons including treatment of recurrent ear infections, alleviation of dizziness, and restoration of hearing loss. A typical ear surgery consists of a tympanomastoidectomy in which both the middle ear is explored via a tympanic membrane flap and the bone behind the ear is removed via mastoidectomy to treat disease and/or provide additional access. The mastoid dissection is performed using a high-speed drill to excavate bone based on a pre-operative CT scan. Intraoperatively, the surface of the mastoid component of the temporal bone provides visual feedback allowing the surgeon to guide their dissection. Dissection begins in "safe areas" which, based on surface topography, are believed to be correlated with greatest distance from surface to vital anatomy thus decreasing the chance of injury to the brain, large blood vessels (e.g. the internal jugular vein and internal carotid artery), the inner ear, and the facial nerve. "Safe areas" have been identified based on surgical experience with no identifiable studies showing correlation of the surface with subsurface anatomy. The purpose of our study was to investigate whether such a correlation exists. Through a three-step registration process, we defined a correspondence between each of twenty five clinically-applicable temporal bone CT scans of patients and an atlas and explored displacement and angular differences of surface topography and depth of critical structures from the surface of the skull. The results of this study reflect current knowledge of osteogenesis and anatomy. Based on two features (distance and angular difference), two regions (suprahelical and posterior) of the temporal bone show the least variability between surface and subsurface anatomy.
Primary Ewing's Sarcoma of the temporal bone in an infant.
Goudarzipour, Kourosh; Shamsian, Shahin; Alavi, Samin; Nourbakhsh, Kazem; Aghakhani, Roxana; Eydian, Zahra; Arzanian, Mohammad Taghi
2015-04-01
Introduction : Ewing's sarcoma is the second most common primary malignant tumor of bone found in children after Osteosarcoma. It accounts for 4-9% of primary malignant bone tumors and it affects bones of the skull or face in only 1-4% of cases. Hence it rarely affects the head and neck. Subject and Method : In this case report, we describe a case of primary Ewing's sarcoma occurring in the temporal bone. The tumor was surgically excised, and the patient underwent chemotherapy for ten months. Results : Neither recurrence nor distant metastasis was noted in these 10 months after surgery but about 18 months after surgery our patient was expired. Conclusion : Although the prognosis of Ewing's sarcoma is generally poor because of early metastasis to the lungs and to other bones, a review of the article suggested that Ewing's sarcoma occurring in the skull can often be successfully managed by intensive therapy with radical excision and chemotherapy. This result was supported by the case reported here.
Cochlear pathology in chronic suppurative otitis media.
Walby, A P; Barrera, A; Schuknecht, H F
1983-01-01
Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.
Andersen, Steven Arild Wuyts; Mikkelsen, Peter Trier; Konge, Lars; Cayé-Thomasen, Per; Sørensen, Mads Sølvsten
2016-01-01
The cognitive load (CL) theoretical framework suggests that working memory is limited, which has implications for learning and skills acquisition. Complex learning situations such as surgical skills training can potentially induce a cognitive overload, inhibiting learning. This study aims to compare CL in traditional cadaveric dissection training and virtual reality (VR) simulation training of mastoidectomy. A prospective, crossover study. Participants performed cadaveric dissection before VR simulation of the procedure or vice versa. CL was estimated by secondary-task reaction time testing at baseline and during the procedure in both training modalities. The national Danish temporal bone course. A total of 40 novice otorhinolaryngology residents. Reaction time was increased by 20% in VR simulation training and 55% in cadaveric dissection training of mastoidectomy compared with baseline measurements. Traditional dissection training increased CL significantly more than VR simulation training (p < 0.001). VR simulation training imposed a lower CL than traditional cadaveric dissection training of mastoidectomy. Learning complex surgical skills can be a challenge for the novice and mastoidectomy skills training could potentially be optimized by employing VR simulation training first because of the lower CL. Traditional dissection training could then be used to supplement skills training after basic competencies have been acquired in the VR simulation. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Bats' avoidance of real and virtual objects: implications for the sonar coding of object size.
Goerlitz, Holger R; Genzel, Daria; Wiegrebe, Lutz
2012-01-01
Fast movement in complex environments requires the controlled evasion of obstacles. Sonar-based obstacle evasion involves analysing the acoustic features of object-echoes (e.g., echo amplitude) that correlate with this object's physical features (e.g., object size). Here, we investigated sonar-based obstacle evasion in bats emerging in groups from their day roost. Using video-recordings, we first show that the bats evaded a small real object (ultrasonic loudspeaker) despite the familiar flight situation. Secondly, we studied the sonar coding of object size by adding a larger virtual object. The virtual object echo was generated by real-time convolution of the bats' calls with the acoustic impulse response of a large spherical disc and played from the loudspeaker. Contrary to the real object, the virtual object did not elicit evasive flight, despite the spectro-temporal similarity of real and virtual object echoes. Yet, their spatial echo features differ: virtual object echoes lack the spread of angles of incidence from which the echoes of large objects arrive at a bat's ears (sonar aperture). We hypothesise that this mismatch of spectro-temporal and spatial echo features caused the lack of virtual object evasion and suggest that the sonar aperture of object echoscapes contributes to the sonar coding of object size. Copyright © 2011 Elsevier B.V. All rights reserved.
Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun
2018-07-01
This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.
Bone scan in metabolic bone diseases. Review.
Abdelrazek, Saeid; Szumowski, Piotr; Rogowski, Franciszek; Kociura-Sawicka, Agnieszka; Mojsak, Małgorzata; Szorc, Małgorzata
2012-08-25
Metabolic bone disease encompasses a number of disorders that tend to present a generalized involvement of the whole skeleton. The disorders are mostly related to increased bone turnover and increased uptake of radiolabelled diphosphonate. Skeletal uptake of 99mTc-labelled diphosphonate depends primarily upon osteoblastic activity, and to a lesser extent, skeletal vascularity. A bone scan image therefore presents a functional display of total skeletal metabolism and has valuable role to play in the assessment of patients with metabolic bone disorders. However, the bone scan appearances in metabolic bone disease are often non-specific, and their recognition depends on increased tracer uptake throughout the whole skeleton. It is the presence of local lesions, as in metastatic disease, that makes a bone scan appearance obviously abnormal. In the early stages, there will be difficulty in evaluating the bone scans from many patients with metabolic bone disease. However, in the more severe cases scan appearances can be quite striking and virtually diagnostic.
Design and properties of 3D scaffolds for bone tissue engineering.
Gómez, S; Vlad, M D; López, J; Fernández, E
2016-09-15
In this study, the Voronoi tessellation method has been used to design novel bone like three dimension (3D) porous scaffolds. The Voronoi method has been processed with computer design software to obtain 3D virtual isotropic porous interconnected models, exactly matching the main histomorphometric indices of trabecular bone (trabecular thickness, trabecular separation, trabecular number, bone volume to total volume ratio, bone surface to bone volume ratio, etc.). These bone like models have been further computed for mechanical (elastic modulus) and fluid mass transport (permeability) properties. The results show that the final properties of the scaffolds can be controlled during their microstructure and histomorphometric initial design stage. It is also shown that final properties can be tuned during the design stage to exactly match those of trabecular natural bone. Moreover, identical total porosity models can be designed with quite different specific bone surface area and thus, this specific microstructural feature can be used to favour cell adhesion, migration and, ultimately, new bone apposition (i.e. osteoconduction). Once the virtual models are fully characterized and optimized, these can be easily 3D printed by additive manufacturing and/or stereolitography technologies. The significance of this article goes far beyond the specific objectives on which it is focussed. In fact, it shows, in a guided way, the entire novel process that can be followed to design graded porous implants, whatever its external shape and geometry, but internally tuned to the exact histomorphometric indices needed to match natural human tissues microstructures and, consequently, their mechanical and fluid properties, among others. The significance is even more relevant nowadays thanks to the available new computing and design software that is easily linked to the 3D printing new technologies. It is this transversality, at the frontier of different disciplines, the main characteristic that gives this article a high scientific impact and interest to a broaden audience. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Middle ear tuberculosis: diagnostic criteria.
Jesić, Snezana; Stosić, Svetlana; Milenković, Branislava; Nesić, Vladimir; Dudvarski, Zoran; Jotić, Ana; Slijepcević, Nikola
2009-01-01
Tuberculous otitis is a diagnostic problem due to the difficulty to obtain microbiological, histomorphological and cytological confirmation of the disease. Our objective was to compare clinical and radiological characteristic and development of otogenic complications in patients with tuberculous otitis and otitis with cholesteatoma as the most destructive form of chronic nonspecific otitis in the purpose of establishing the diagnostic criteria for tuberculous otitis. Medical records of 12 patients with tuberculous otitis and 163 patients with cholesteatoma treated at the Institute of Otorhinolaryngology and Maxillofacial Surgery in Belgrade during the eight-year period were analyzed. All of the patients underwent otomicroscopic, audiological and radiological examination of the thorax and temporal bone, microbiological examination of the secretion and histomorphological examination of the tissue taken during middle ear surgery. Statistical analysis was done using chi2 test with Yates correction. Otogenic complication as facial palsy and sensorineural hearing loss were more frequent in tuberculous otitis patients, than in cholesteatoma. Also, fistulas of the labyrinth and facial canal bone destruction were also more frequent in tuberculous otitis than in cholesteatoma. A larger extent of temporal bone destruction was noticed on CT scans of the temporal bone in half of the patents with tuberculous otitis. Coexistence with miliary pulmonary tuberculosis was detected in one third of the patients. There were no microbiological or histomorphological confirmations of the disease, except in one case with positive ZiehI-Neelsen staining. Tuberculous otitis media should be considered in patients with serious otogenic complications and with shorter duration of ear discharge, and in association with diagnosed miliary pulmonary tuberculosis and extensive temporal bone destruction. Polymerase chain reaction still is not reliable for diagnosis.
Femur bone strength in Tyrannosaurus rex: A study of sexual dimorphism
NASA Astrophysics Data System (ADS)
Lee, Scott
2012-04-01
Tyrannosaurus rex is the iconic species of a fearsome predator and is held in fascination by virtually everyone. Like many other species, Tyrannosaurs rex displayed sexual dimorphism with the females larger than the males. The femur bones of 14 fossil specimens were examined to determine if the maximum running abilities were significantly different for the two genders. No significant difference is observed.
Lockwood, Charles A; Lynch, John M; Kimbel, William H
2002-12-01
The hominid temporal bone offers a complex array of morphology that is linked to several different functional systems. Its frequent preservation in the fossil record gives the temporal bone added significance in the study of human evolution, but its morphology has proven difficult to quantify. In this study we use techniques of 3D geometric morphometrics to quantify differences among humans and great apes and discuss the results in a phylogenetic context. Twenty-three landmarks on the ectocranial surface of the temporal bone provide a high level of anatomical detail. Generalized Procrustes analysis (GPA) is used to register (adjust for position, orientation and scale) landmark data from 405 adults representing Homo, Pan, Gorilla and Pongo. Principal components analysis of residuals from the GPA shows that the major source of variation is between humans and apes. Human characteristics such as a coronally orientated petrous axis, a deep mandibular fossa, a projecting mastoid process, and reduced lateral extension of the tympanic element strongly impact the analysis. In phenetic cluster analyses, gorillas and orangutans group together with respect to chimpanzees, and all apes group together with respect to humans. Thus, the analysis contradicts depictions of African apes as a single morphotype. Gorillas and orangutans lack the extensive preglenoid surface of chimpanzees, and their mastoid processes are less medially inflected. These and other characters shared by gorillas and orangutans are probably primitive for the African hominid clade.
Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.
Gupta, Rajiv; Bartling, Soenke H; Basu, Samit K; Ross, William R; Becker, Hartmut; Pfoh, Armin; Brady, Thomas; Curtin, Hugh D
2004-09-01
A CT scanner employing a digital flat-panel detector is capable of very high spatial resolution as compared with a multi-section CT (MSCT) scanner. Our purpose was to determine how well a prototypical volume CT (VCT) scanner with a flat-panel detector system defines fine structures in temporal bone. Four partially manipulated temporal-bone specimens were imaged by use of a prototypical cone-beam VCT scanner with a flat-panel detector system at an isometric resolution of 150 microm at the isocenter. These specimens were also depicted by state-of-the-art multisection CT (MSCT). Forty-two structures imaged by both scanners were qualitatively assessed and rated, and scores assigned to VCT findings were compared with those of MSCT. Qualitative assessment of anatomic structures, lesions, cochlear implants, and middle-ear hearing aids indicated that image quality was significantly better with VCT (P < .001). Structures near the spatial-resolution limit of MSCT (e.g., bony covering of the tympanic segment of the facial canal, the incudo-stapedial joint, the proximal vestibular aqueduct, the interscalar septum, and the modiolus) had higher contrast and less partial-volume effect with VCT. The flat-panel prototype provides better definition of fine osseous structures of temporal bone than that of currently available MSCT scanners. This study provides impetus for further research in increasing spatial resolution beyond that offered by the current state-of-the-art scanners.
Optimization of 3D Print Material for the Recreation of Patient-Specific Temporal Bone Models.
Haffner, Max; Quinn, Austin; Hsieh, Tsung-Yen; Strong, E Bradley; Steele, Toby
2018-05-01
Identify the 3D printed material that most accurately recreates the visual, tactile, and kinesthetic properties of human temporal bone Subjects and Methods: Fifteen study participants with an average of 3.6 years of postgraduate training and 56.5 temporal bone (TB) procedures participated. Each participant performed a mastoidectomy on human cadaveric TB and five 3D printed TBs of different materials. After drilling each unique material, participants completed surveys to assess each model's appearance and physical likeness on a Likert scale from 0 to 10 (0 = poorly representative, 10 = completely life-like). The 3D models were acquired by computed tomography (CT) imaging and segmented using 3D Slicer software. Polyethylene terephthalate (PETG) had the highest average survey response for haptic feedback (HF) and appearance, scoring 8.3 (SD = 1.7) and 7.6 (SD = 1.5), respectively. The remaining plastics scored as follows for HF and appearance: polylactic acid (PLA) averaged 7.4 and 7.6, acrylonitrile butadiene styrene (ABS) 7.1 and 7.2, polycarbonate (PC) 7.4 and 3.9, and nylon 5.6 and 6.7. A PETG 3D printed temporal bone models performed the best for realistic appearance and HF as compared with PLA, ABS, PC, and nylon. The PLA and ABS were reliable alternatives that also performed well with both measures.
Outcomes and special considerations of cochlear implantation in waardenburg syndrome.
Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke
2011-08-01
The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.
Cornelius, Carl-Peter; Smolka, Wenko; Giessler, Goetz A; Wilde, Frank; Probst, Florian A
2015-06-01
Preoperative planning of mandibular reconstruction has moved from mechanical simulation by dental model casts or stereolithographic models into an almost completely virtual environment. CAD/CAM applications allow a high level of accuracy by providing a custom template-assisted contouring approach for bone flaps. However, the clinical accuracy of CAD reconstruction is limited by the use of prebent reconstruction plates, an analogue step in an otherwise digital workstream. In this paper the integration of computerized, numerically-controlled (CNC) milled, patient-specific mandibular plates (PSMP) within the virtual workflow of computer-assisted mandibular free fibula flap reconstruction is illustrated in a clinical case. Intraoperatively, the bone segments as well as the plate arms showed a very good fit. Postoperative CT imaging demonstrated close approximation of the PSMP and fibular segments, and good alignment of native mandible and fibular segments and intersegmentally. Over a follow-up period of 12 months, there was an uneventful course of healing with good bony consolidation. The virtual design and automated fabrication of patient-specific mandibular reconstruction plates provide the missing link in the virtual workflow of computer-assisted mandibular free fibula flap reconstruction. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.
Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R
2017-04-01
Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p < 0.05, AUC = 0.74) or a low proportion of failed cortical bone tissue for torsional loading (p < 0.005, AUC = 0.84). Using post-hoc thresholds of a compressive strength of four times body-weight and a proportional of failed cortical bone tissue of 5%, the test identified all nine patients who failed clinically (100% sensitivity; 40.9% positive predictive value) and over three fourths of those (43 of 56) who progressed to successful healing (76.8% specificity; 100% negative predictive value). In this study, VST identified all patients who progressed to full, uneventful union after fixator removal; thus, we conclude that this new test has the potential to provide a quantitative, objective means of identifying tibia-fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Wang, You-Yuan; Fan, Song; Zhang, Han-Qing; Lin, Zhao-Yu; Ye, Jian-Tao; Li, Jin-Song
2016-06-01
Reconstruction of maxillary and midfacial defects due to tumor ablation is challenging to conventional operation. The purposes of this study are to evaluate the precise 3-dimensional position of the fibular flap in reconstruction of maxillary defects assisted by virtual surgical planning and to assess the postoperative outcomes compared with conventional surgery. We retrospectively reviewed 18 consecutive patients who underwent maxillary reconstruction with a vascularized fibular flap assisted by virtual surgical planning after maxillary or midfacial tumor ablation. Conventional surgery was performed in another 15 patients. Proplan CMF surgical planning (Materialise, Leuven, Belgium) was performed preoperatively in the virtual planning group. Fibular flaps were harvested and underwent osteotomy assisted by prefabricated cutting guides, and the maxilla and midface were resected and reconstructed assisted by the prefabricated cutting guides and templates in the virtual planning group. The operative time and fibular flap positions were evaluated in the 2 groups. Postoperative fibular positions of the maxillary reconstruction were compared with virtual plans in the virtual planning group. The postoperative facial appearance and occlusal function were assessed. The operations were performed successfully without complications. The ischemia time and total operative time were shorter in the virtual planning group than those in the conventional surgery group (P < .05). High precision of the cutting guides and templates was found on both the fibula and maxilla in the virtual planning group. The positions of the fibular flaps, including the vertical and horizontal positions, were more accurate in the virtual planning group than those in the conventional surgery group (P < .05). Bone-to-bone contact between the maxilla and fibular segments was more precise in the virtual planning group (P < .05). Postoperative computed tomography scans showed excellent contour of the fibular flap segments in accordance with the virtual plans in the virtual planning group. All patients were alive with no evidence of disease. Functional mandibular range of motion, good occlusion, and an ideal facial appearance were observed in the virtual planning group. Virtual surgical planning appears to achieve precise maxillary reconstruction with a vascularized fibular flap after tumor ablation, as well as an ideal facial appearance and function after dental rehabilitation. The use of prefabricated cutting guides and plates eases fibular flap molding and placement, minimizes operating time, and improves clinical outcomes. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Scala tympani cochleostomy II: topography and histology.
Adunka, Oliver F; Radeloff, Andreas; Gstoettner, Wolfgang K; Pillsbury, Harold C; Buchman, Craig A
2007-12-01
To assess intracochlear trauma using two different round window-related cochleostomy techniques in human temporal bones. Twenty-eight human temporal bones were included in this study. In 21 specimens, cochleostomies were initiated inferior to the round window (RW) annulus. In seven bones, cochleostomies were drilled anterior-inferior to the RW annulus. Limited cochlear implant electrode insertions were performed in 19 bones. In each specimen, promontory anatomy and cochleostomy drilling were photographically documented. Basal cochlear damage was assessed histologically and electrode insertion properties were documented in implanted bones. All implanted specimens showed clear scala tympani electrode placements regardless of cochleostomy technique. All 21 inferior cochleostomies were atraumatic. Anterior-inferior cochleostomies resulted in various degrees of intracochlear trauma in all seven bones. For atraumatic opening of the scala tympani using a cochleostomy approach, initiation of drilling should proceed from inferior to the round window annulus, with gradual progression toward the undersurface of the lumen. While cochleostomies initiated anterior-inferior to the round window annulus resulted in scala tympani opening, many of these bones displayed varying degrees of intracochlear trauma that may result in hearing loss. When intracochlear drilling is avoided, the anterior bony margin of the cochleostomy remains a significant intracochlear impediment to in-line electrode insertion.
Tekes, Aylin; Ishman, Stacey L; Baugher, Katherine M; Brown, David J; Lin, Sandra Y; Tunkel, David E; Unalp-Arida, Aynur; Huisman, Thierry A G M
2013-07-01
This study aimed to determine the spectrum of temporal bone computed tomography (CT) abnormalities in children with conductive hearing loss (CHL) with and without microtia. From 1993 to 2008, a total of 3396 pediatric records including CHL were reviewed at our institution and revealed 180 cases of persistent CHL, 46 of whom had diagnostic temporal bone CT examinations. All of these examinations were systematically reviewed by two pediatric neuroradiologists, working in consensus, who had 5 and 18 years, respectively, of dedicated pediatric neuroradiology experience. Of the 46 children, 16 were boys and 30 were girls (age: 0.2-16 years; mean: 5 years). Also, 21 (46%) children had microtia and 25 (54%) children did not, as determined by clinical evaluation. External auditory canal atresia/stenosis (EAC-A/S) was the most common anomaly in both microtia and non-microtia groups. Two or more anomalies were observed in 18/21 children with microtia. The frequency of EAC-A/S was greater in children with microtia versus those without it (86% versus 32%, respectively; P = 0.0003). Syndromic diagnoses were also significantly more frequently made in children with microtia versus those without microtia (76% versus 20%, respectively; P = 0.0001). Temporal bone CT scans were normal in 10 children (22%) with persistent CHL. Microtia is an important finding in children with CHL. EAC and middle ear/ossicle anomalies were significantly more frequently seen in children with microtia, and multiple anomalies and bilateral microtia were more common in children with syndromic associations. These findings highlight the importance of understanding the embryological development of the temporal bone. The presence of one anomaly should raise suspicion of the possibility of other anomalies, especially in the setting of microtia. Bilateral microtia and multiple anomalies should also raise suspicion of genetic syndromes. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Less-lethal hybrid ammunition wounds: a forensic assessment introducing bullet-skin-bone entity.
de Freminville, Humbert; Prat, Nicolas; Rongieras, Frederic; Voiglio, Eric J
2010-09-01
Agencies all around the world now use less-lethal weapons with homogeneous missiles such as bean bag or rubber bullets. Contusions and sometimes significant morbidity have been reported. This study focuses on wounds caused by hybrid ammunition with the pathologists' flap-by-flap procedure. Twenty-four postmortem human subjects were used, and lesions caused on frontal, temporal, sternal, and left tibial regions by a 40-mm hybrid ammunition (33 g weight) were evaluated on various distance range. The 50% risk of fractures occurred at 79.2 m/sec on the forehead, 72.9 m/sec on the temporal, 72.5 m/sec on the sternum, and 76.7 m/sec on the tibia. Skin lesions were not predictors of bone fracture. There was no correlation between soft and bone tissue observed lesions and impact velocity (correlated to distance range). Lesions observed with hybrid ammunition were the result of bullet-skin-bone entity as the interaction of the projectile on skin and bone tissues.
Navigational strategies underlying phototaxis in larval zebrafish.
Chen, Xiuye; Engert, Florian
2014-01-01
Understanding how the brain transforms sensory input into complex behavior is a fundamental question in systems neuroscience. Using larval zebrafish, we study the temporal component of phototaxis, which is defined as orientation decisions based on comparisons of light intensity at successive moments in time. We developed a novel "Virtual Circle" assay where whole-field illumination is abruptly turned off when the fish swims out of a virtually defined circular border, and turned on again when it returns into the circle. The animal receives no direct spatial cues and experiences only whole-field temporal light changes. Remarkably, the fish spends most of its time within the invisible virtual border. Behavioral analyses of swim bouts in relation to light transitions were used to develop four discrete temporal algorithms that transform the binary visual input (uniform light/uniform darkness) into the observed spatial behavior. In these algorithms, the turning angle is dependent on the behavioral history immediately preceding individual turning events. Computer simulations show that the algorithms recapture most of the swim statistics of real fish. We discovered that turning properties in larval zebrafish are distinctly modulated by temporal step functions in light intensity in combination with the specific motor history preceding these turns. Several aspects of the behavior suggest memory usage of up to 10 swim bouts (~10 sec). Thus, we show that a complex behavior like spatial navigation can emerge from a small number of relatively simple behavioral algorithms.
Virtual reconstruction of glenoid bone defects using a statistical shape model.
Plessers, Katrien; Vanden Berghe, Peter; Van Dijck, Christophe; Wirix-Speetjens, Roel; Debeer, Philippe; Jonkers, Ilse; Vander Sloten, Jos
2018-01-01
Description of the native shape of a glenoid helps surgeons to preoperatively plan the position of a shoulder implant. A statistical shape model (SSM) can be used to virtually reconstruct a glenoid bone defect and to predict the inclination, version, and center position of the native glenoid. An SSM-based reconstruction method has already been developed for acetabular bone reconstruction. The goal of this study was to evaluate the SSM-based method for the reconstruction of glenoid bone defects and the prediction of native anatomic parameters. First, an SSM was created on the basis of 66 healthy scapulae. Then, artificial bone defects were created in all scapulae and reconstructed using the SSM-based reconstruction method. For each bone defect, the reconstructed surface was compared with the original surface. Furthermore, the inclination, version, and glenoid center point of the reconstructed surface were compared with the original parameters of each scapula. For small glenoid bone defects, the healthy surface of the glenoid was reconstructed with a root mean square error of 1.2 ± 0.4 mm. Inclination, version, and glenoid center point were predicted with an accuracy of 2.4° ± 2.1°, 2.9° ± 2.2°, and 1.8 ± 0.8 mm, respectively. The SSM-based reconstruction method is able to accurately reconstruct the native glenoid surface and to predict the native anatomic parameters. Based on this outcome, statistical shape modeling can be considered a successful technique for use in the preoperative planning of shoulder arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
[Unifocal eosinophilic granuloma of the temporal bone].
Rodríguez Fernández-Freire, A; Porras Alonso, E; Benito Navarro, J R; Rodríguez Pérez, M; Hervás Núñez, M J
2007-01-01
We present a case of a twelve year old child with a eosinophilic granuloma of the temporal bone. The eosinophilic granuloma is the most frecuent and most benign form of the histiocytosis of the Langerhans cells. The frecuency of the othological manifestations of this condition varies between 15-60 percent and radiologically, the images are characterized by litho-lesions with sharp edges. The diagnosis is histological and the treatment includes surgical intervention accompanied by inter-lesion corticoid-therapy and/or radiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vignaud, J.; Jardin, C.; Rosen, L.
1986-01-01
This is an English translation of volume 17-1 of Traite de radiodiagnostic and represents a reasonably complete documentation of the diseases of the temporal bone that have imaging manifestations. The book begins with chapters on embryology, anatomy and radiography anatomy; it continues with blood supply and an overview of temporal bone pathology. Subsequent chapters cover malformations, trauma, infections, tumors, postoperative changes, glomus tumors, vertebasilar insufficiency, and facial nerve canal lesions. A final chapter demonstrates and discusses magnetic resonance images of the ear and cerebellopontine angle.
Gradenigo's syndrome--surgical management in a child.
Humayun, Hassan Nabeel; Akhtar, Shabbir; Ahmed, Shakeel
2011-04-01
Otits media is a common problem. Some of its complications that were seen frequently in the preantibiotic era are rare today. We report a case of an 8 year boy who presented with earache, retro-orbital pain and diplopia secondary to a sixth nerve palsy--Gradenigo's syndrome. In this syndrome infection from the middle ear spreads medially to the petrous apex of the temporal bone. Work-up includes CT scan of the temporal bones. Timely management with intravenous antibiotics (+ surgery) is needed to prevent intra-cranial complications.
Post-marketing surveillance of CustomBone Service implanted in children under 7 years old.
Frassanito, Paolo; Tamburrini, Gianpiero; Massimi, Luca; Di Rocco, Concezio; Nataloni, Angelo; Fabbri, Greta; Caldarelli, Massimo
2015-01-01
The CustomBone Service is a bioceramic implant suitable for cranial repair in both adults and children, although there are no clinical data about its use in children under 7 years of age. This surveillance study investigates the outcome in this age group. Twenty-eight children under 7 years old (range, 2.5-6 years) received CustomBone Service from July 2006 to May 2013 in 16 international hospitals. Data of 23 children (12 males and 11 females), harboring 24 prosthesis, were available with a minimum follow-up of 1 year. Sites of the cranial defect were frontal or parietal (20.8 % each), parieto-temporal (16.7 %), fronto-parietal or occipital (12.5 % each), fronto-parieto-temporal or fronto-temporal (8.3 % each). Initial diseases were trauma (54.2 %), malformation (37.5 %), or tumor of the bone/skin (8.3 %). Rupture of the implant occurred in a single case during the implant (1/26 surgeries, 3.8 %) and the cranial repair was achieved by means of the back-up prosthesis. Five adverse events were registered during the follow-up period consisting of three cases of fracture and two of exposure/infection of the prosthesis. All cases required the removal of the device (20.8 %). The failure rate of CustomBone Service under 7 years of age was higher than reported in adults and children over 7 years old (20.8 vs. 3.8 %), However, CustomBone Service may be considered a valid option under 7 years old since other materials are burdened by more significant rates of complications in the long-term period. Due to specific properties of this material, indication to CustomBone Service in toddlers should be carefully evaluated by the surgeon on a case-by-case basis.
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Dagle, Alicia B.; Kazanzides, Peter; Boctor, Emad M.
2016-03-01
Endonasal transsphenoidal surgery is an effective approach for pituitary adenoma resection, yet it poses the serious risk of internal carotid artery injury. We propose to visualize these carotid arteries, which are hidden by bone, with an optical fiber attached to a surgical tool and a transcranial ultrasound probe placed on the patient's temple (i.e. intraoperative photoacoustic imaging). To investigate energy requirements for vessel visualization, experiments were conducted with a phantom containing ex vivo sheep brain, ex vivo bovine blood, and 0.5-2.5 mm thick human cadaveric skull specimens. Photoacoustic images were acquired with 1.2-9.3 mJ laser energy, and the resulting vessel contrast was measured at each energy level. The distal vessel boundary was difficult to distinguish at the chosen contrast threshold for visibility (4.5 dB), which was used to determine the minimum energies for vessel visualization. The blood vessel was successfully visualized in the presence of the 0-2.0 mm thick sphenoid and temporal bones with up to 19.2 dB contrast. The minimum energy required ranged from 1.2-5.0 mJ, 4.2-5.9 mJ, and 4.6-5.2 mJ for the 1.0 temporal and 0-1.5 mm sphenoid bones, 1.5 mm temporal and 0-0.5 mm sphenoid bones, and 2.0 mm temporal and 0-0.5 mm sphenoid bones, respectively, which corresponds to a fluence range of 4-21 mJ/cm2. These results hold promise for vessel visualization within safety limits. In a separate experiment, a mock tool tip was placed, providing satisfactory preliminary evidence that surgical tool tips can be visualized simultaneously with blood vessels.
Jeevan, Dhruve S; Ormond, D Ryan; Kim, Ana H; Meiteles, Lawrence Z; Stidham, Katrina R; Linstrom, Christopher; Murali, Raj
2015-04-01
Temporal bone encephalocele has become less common as the incidence of chronic mastoid infection and surgery for this condition has decreased. As a result, the diagnosis is often delayed, and the encephalocele is often an incidental finding. This situation can result in serious neurologic complications with patients presenting with cerebrospinal fluid leak and meningitis. We review the occurrence of, characteristics of, and repair experience with temporal encephaloceles from 2000-2012. We conducted a retrospective review of 32 patients undergoing combined mastoidectomy and middle cranial fossa craniotomy for the treatment of temporal encephalocele. The diagnosis of temporal encephalocele was made in all patients using high-resolution temporal bone computed tomography and magnetic resonance imaging. At the time of diagnosis, 12 patients had confirmed cerebrospinal fluid leak; other common presenting symptoms included hearing loss and ear fullness. Tegmen defect was most commonly due to chronic otitis media (n = 14). Of these patients, 8 had undergone prior mastoidectomy, suggesting an iatrogenic cause. Other etiologies included radiation exposure, congenital defects, and spontaneous defects. Additionally, 2 patients presented with meningitis; 1 patient had serious neurologic deficits resulting from venous infarction. The risk of severe neurologic complications after the herniation of intracranial contents through a tegmen defect necessitates prompt recognition and appropriate management. Computed tomography and magnetic resonance imaging aid in definitive diagnosis. A combined mastoid/middle fossa approach allows for sustainable repair with adequate exposure of defects and support of intracranial contents. Copyright © 2015 Elsevier Inc. All rights reserved.
Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media
NASA Astrophysics Data System (ADS)
Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying
2011-11-01
A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.
Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.
Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter
2004-07-01
A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.
Lockwood, Charles A; Lynch, John M; Kimbel, William H
2002-01-01
The hominid temporal bone offers a complex array of morphology that is linked to several different functional systems. Its frequent preservation in the fossil record gives the temporal bone added significance in the study of human evolution, but its morphology has proven difficult to quantify. In this study we use techniques of 3D geometric morphometrics to quantify differences among humans and great apes and discuss the results in a phylogenetic context. Twenty-three landmarks on the ectocranial surface of the temporal bone provide a high level of anatomical detail. Generalized Procrustes analysis (GPA) is used to register (adjust for position, orientation and scale) landmark data from 405 adults representing Homo, Pan, Gorilla and Pongo. Principal components analysis of residuals from the GPA shows that the major source of variation is between humans and apes. Human characteristics such as a coronally orientated petrous axis, a deep mandibular fossa, a projecting mastoid process, and reduced lateral extension of the tympanic element strongly impact the analysis. In phenetic cluster analyses, gorillas and orangutans group together with respect to chimpanzees, and all apes group together with respect to humans. Thus, the analysis contradicts depictions of African apes as a single morphotype. Gorillas and orangutans lack the extensive preglenoid surface of chimpanzees, and their mastoid processes are less medially inflected. These and other characters shared by gorillas and orangutans are probably primitive for the African hominid clade. PMID:12489757
Vestibular evoked myogenic potentials (VEMP) can detect asymptomatic saccular hydrops.
Lin, Ming-Yee; Timmer, Ferdinand C A; Oriel, Brad S; Zhou, Guangwei; Guinan, John J; Kujawa, Sharon G; Herrmann, Barbara S; Merchant, Saumil N; Rauch, Steven D
2006-06-01
The objective of this study was to explore the useful of vestibular evoked myogenic potential (VEMP) testing for detecting endolymphatic hydrops, especially in the second ear of patients with unilateral Ménière disease (MD). This study was performed at a tertiary care academic medical center. Part I consisted of postmortem temporal bone specimens from the temporal bone collection of the Massachusetts Eye & Ear Infirmary; part II consisted of consecutive consenting adult patients (n = 82) with unilateral MD by American Academy of Otolaryngology-Head and Neck Surgery criteria case histories. Outcome measures consisted of VEMP thresholds in patients and histologic saccular endolymphatic hydrops in postmortem temporal bones. Saccular hydrops was observed in the asymptomatic ear in six of 17 (35%) of temporal bones from donors with unilateral MD. Clinic patients with unilateral MD showed elevated mean VEMP thresholds and altered VEMP tuning in their symptomatic ears and, to a lesser degree, in their asymptomatic ears. Specific VEMP frequency and tuning criteria were used to define a "Ménière-like" response. This "Ménière-like" response was seen in 27% of asymptomatic ears of our patients with unilateral MD. Bilateral involvement is seen in approximately one third of MD cases. Saccular hydrops appears to precede symptoms in bilateral MD. Changes in VEMP threshold and tuning appear to be sensitive to these structural changes in the saccule. If so, then VEMP may be useful as a detector of asymptomatic saccular hydrops and as a predictor of evolving bilateral MD.
Effects of Bone Vibrator Position on Auditory Spatial Perception Tasks.
McBride, Maranda; Tran, Phuong; Pollard, Kimberly A; Letowski, Tomasz; McMillan, Garnett P
2015-12-01
This study assessed listeners' ability to localize spatially differentiated virtual audio signals delivered by bone conduction (BC) vibrators and circumaural air conduction (AC) headphones. Although the skull offers little intracranial sound wave attenuation, previous studies have demonstrated listeners' ability to localize auditory signals delivered by a pair of BC vibrators coupled to the mandibular condyle bones. The current study extended this research to other BC vibrator locations on the skull. Each participant listened to virtual audio signals originating from 16 different horizontal locations using circumaural headphones or BC vibrators placed in front of, above, or behind the listener's ears. The listener's task was to indicate the signal's perceived direction of origin. Localization accuracy with the BC front and BC top positions was comparable to that with the headphones, but responses for the BC back position were less accurate than both the headphones and BC front position. This study supports the conclusion of previous studies that listeners can localize virtual 3D signals equally well using AC and BC transducers. Based on these results, it is apparent that BC devices could be substituted for AC headphones with little to no localization performance degradation. BC headphones can be used when spatial auditory information needs to be delivered without occluding the ears. Although vibrator placement in front of the ears appears optimal from the localization standpoint, the top or back position may be acceptable from an operational standpoint or if the BC system is integrated into headgear. © 2015, Human Factors and Ergonomics Society.
VERS: a virtual environment for reconstructive surgery planning
NASA Astrophysics Data System (ADS)
Montgomery, Kevin N.
1997-05-01
The virtual environment for reconstructive surgery (VERS) project at the NASA Ames Biocomputation Center is applying virtual reality technology to aid surgeons in planning surgeries. We are working with a craniofacial surgeon at Stanford to assemble and visualize the bone structure of patients requiring reconstructive surgery either through developmental abnormalities or trauma. This project is an extension of our previous work in 3D reconstruction, mesh generation, and immersive visualization. The current VR system, consisting of an SGI Onyx RE2, FakeSpace BOOM and ImmersiveWorkbench, Virtual Technologies CyberGlove and Ascension Technologies tracker, is currently in development and has already been used to visualize defects preoperatively. In the near future it will be used to more fully plan the surgery and compute the projected result to soft tissue structure. This paper presents the work in progress and details the production of a high-performance, collaborative, and networked virtual environment.
Wise Regulates Bone Deposition through Genetic Interactions with Lrp5
Ellies, Debra L.; Economou, Androulla; Viviano, Beth; Rey, Jean-Philippe; Paine-Saunders, Stephenie; Krumlauf, Robb; Saunders, Scott
2014-01-01
In this study using genetic approaches in mouse we demonstrate that the secreted protein Wise plays essential roles in regulating early bone formation through its ability to modulate Wnt signaling via interactions with the Lrp5 co-receptor. In Wise−/− mutant mice we find an increase in the rate of osteoblast proliferation and a transient increase in bone mineral density. This change in proliferation is dependent upon Lrp5, as Wise;Lrp5 double mutants have normal bone mass. This suggests that Wise serves as a negative modulator of Wnt signaling in active osteoblasts. Wise and the closely related protein Sclerostin (Sost) are expressed in osteoblast cells during temporally distinct early and late phases in a manner consistent with the temporal onset of their respective increased bone density phenotypes. These data suggest that Wise and Sost may have common roles in regulating bone development through their ability to control the balance of Wnt signaling. We find that Wise is also required to potentiate proliferation in chondrocytes, serving as a potential positive modulator of Wnt activity. Our analyses demonstrate that Wise plays a key role in processes that control the number of osteoblasts and chondrocytes during bone homeostasis and provide important insight into mechanisms regulating the Wnt pathway during skeletal development. PMID:24789067
Wise regulates bone deposition through genetic interactions with Lrp5.
Ellies, Debra L; Economou, Androulla; Viviano, Beth; Rey, Jean-Philippe; Paine-Saunders, Stephenie; Krumlauf, Robb; Saunders, Scott
2014-01-01
In this study using genetic approaches in mouse we demonstrate that the secreted protein Wise plays essential roles in regulating early bone formation through its ability to modulate Wnt signaling via interactions with the Lrp5 co-receptor. In Wise-/- mutant mice we find an increase in the rate of osteoblast proliferation and a transient increase in bone mineral density. This change in proliferation is dependent upon Lrp5, as Wise;Lrp5 double mutants have normal bone mass. This suggests that Wise serves as a negative modulator of Wnt signaling in active osteoblasts. Wise and the closely related protein Sclerostin (Sost) are expressed in osteoblast cells during temporally distinct early and late phases in a manner consistent with the temporal onset of their respective increased bone density phenotypes. These data suggest that Wise and Sost may have common roles in regulating bone development through their ability to control the balance of Wnt signaling. We find that Wise is also required to potentiate proliferation in chondrocytes, serving as a potential positive modulator of Wnt activity. Our analyses demonstrate that Wise plays a key role in processes that control the number of osteoblasts and chondrocytes during bone homeostasis and provide important insight into mechanisms regulating the Wnt pathway during skeletal development.
Navigational strategies underlying phototaxis in larval zebrafish
Chen, Xiuye; Engert, Florian
2014-01-01
Understanding how the brain transforms sensory input into complex behavior is a fundamental question in systems neuroscience. Using larval zebrafish, we study the temporal component of phototaxis, which is defined as orientation decisions based on comparisons of light intensity at successive moments in time. We developed a novel “Virtual Circle” assay where whole-field illumination is abruptly turned off when the fish swims out of a virtually defined circular border, and turned on again when it returns into the circle. The animal receives no direct spatial cues and experiences only whole-field temporal light changes. Remarkably, the fish spends most of its time within the invisible virtual border. Behavioral analyses of swim bouts in relation to light transitions were used to develop four discrete temporal algorithms that transform the binary visual input (uniform light/uniform darkness) into the observed spatial behavior. In these algorithms, the turning angle is dependent on the behavioral history immediately preceding individual turning events. Computer simulations show that the algorithms recapture most of the swim statistics of real fish. We discovered that turning properties in larval zebrafish are distinctly modulated by temporal step functions in light intensity in combination with the specific motor history preceding these turns. Several aspects of the behavior suggest memory usage of up to 10 swim bouts (~10 sec). Thus, we show that a complex behavior like spatial navigation can emerge from a small number of relatively simple behavioral algorithms. PMID:24723859
Ashihara, Takashi; Namba, Tsunetoyo; Ikeda, Takanori; Ito, Makoto; Nakazawa, Kazuo; Trayanova, Natalia
2004-02-24
Recent studies have demonstrated that regional capture during cardiac fibrillation is associated with an elevated capture threshold. It is typically assumed that the temporal excitable gap (capture window) during fibrillation reflects the size of the spatial excitable gap (excitable tissue between fibrillation waves). Because capture threshold is high, virtual electrode polarization is expected to be involved in the process. However, little is known about the underlying mechanisms of myocardial capture during fibrillation. To clarify these issues, we conducted altogether 3168 simulations of single spiral wave capture in a bidomain sheet. Unipolar stimuli of strengths 4, 8, 16, and 24 mA and 2-ms duration were delivered at 99 locations in the sheet. We found that cathode-break rather than cathode-make excitation was the dominant mechanism of myocardial capture. When the stimulation site was located diagonally with respect to the core (upper left or lower right if the spiral wave rotates counterclockwise), the cathode-break excitation easily invaded the spatial excitable gap and resulted in a successful capture as a result of the formation of virtual anodes in the direction of the myocardial fibers. Thus, the spatial distribution of the temporal excitable gap did not reflect the spatial excitable gap. The areas exhibiting wide temporal excitable gaps were areas in which the cathode-break excitation wave fronts easily invaded the spatial excitable gap via the virtual anodes. This study provides mechanistic insight into myocardial capture.
Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.
Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan
2011-01-01
With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Polyester Wax: A New Embedding Medium for the Histopathologic Study of Human Temporal Bones
Merchant, Saumil N.; Burgess, Barbara; O'Malley, Jennifer; Jones, Diane; Adams, Joe C.
2007-01-01
Background Celloidin and paraffin are the two common embedding mediums used for histopathologic study of the human temporal bone by light microscopy. Although celloidin embedding permits excellent morphologic assessment, celloidin is difficult to remove, and there are significant restrictions on success with immunostaining. Embedding in paraffin allows immunostaining to be performed, but preservation of cellular detail within the membranous labyrinth is relatively poor. Objectives/Hypothesis Polyester wax is an embedding medium that has a low melting point (37°C), is soluble in most organic solvents, is water tolerant, and sections easily. We hypothesized that embedding in polyester wax would permit good preservation of the morphology of the membranous labyrinth and, at the same time, allow the study of proteins by immunostaining. Methods Nine temporal bones from individuals aged 1 to 94 years removed 2 to 31 hours postmortem, from subjects who had no history of otologic disease, were used. The bones were fixed using 10% formalin, decal-cified using EDTA, embedded in polyester wax, and serially sectioned at a thickness of 8 to 12 μm on a rotary microtome. The block and knife were cooled with frozen CO2 (dry ice) held in a funnel above the block. Sections were placed on glass slides coated with a solution of 1% fish gelatin and 1% bovine albumin, followed by staining of selected sections with hematoxylin and eosin (H&E). Immunostaining was also performed on selected sections using antibodies to 200 kD neurofilament and Na-K-ATPase. Results Polyester wax–embedded sections demonstrated good preservation of cellular detail of the organ of Corti and other structures of the membranous labyrinth, as well as the surrounding otic capsule. The protocol described in this paper was reliable and consistently yielded sections of good quality. Immuno-staining was successful with both antibodies. Conclusion The use of polyester wax as an embedding medium for human temporal bones offers the advantage of good preservation of morphology and ease of immunostaining. We anticipate that in the future, polyester wax embedding will also permit other molecular biologic assays on temporal bone sections such as the retrieval of nucleic acids and the study of proteins using mass spectrometry–based proteomic analysis. PMID:16467713
Late radiation side-effects in three patients undergoing parotid irradiation for benign disease.
Armour, A; Ghanna, P; O'Rielly, B; Habeshaw, T; Symonds, P
2000-01-01
We report three patients in whom standard radiation therapy was given and serious late radiation damage was seen. The first patient suffered recurrent parotiditis and a parotid fistula. He was treated initially with 20 Gy in ten fractions via a 300 kV field. Further irradiation was required 1 year later and 40 Gy was given in 2 Gy fractions by an oblique anterior and posterior wedged photon pair. Ten years later he developed localized temporal bone necrosis. The second patient, with pleomorphic salivary adenoma, developed localized temporal bone necrosis 6 years after 60 Gy had been given using standard fractionation and technique. The third patient received 55 Gy in 25 fractions for a pleomorphic salivary adenoma and after 3 years developed temporal bone necrosis. Sixteen years later the same patient developed cerebellar and brainstem necrosis. All patients developed chronic persistent infection during or shortly after the radiation therapy, which increased local tissue sensitivity to late radiation damage. As a result, severe bone, cerebellar and brainstem necrosis was observed at doses that are normally considered safe. We therefore strongly recommend that any infection in a proposed irradiated area should be treated aggressively, with surgical debridement if necessary, before radiotherapy is administered, or that infection developing during or after irradiation is treated promptly.
Landsat's role in ecological applications of remote sensing.
Warren B. Cohen; Samuel N. Goward
2004-01-01
Remote sensing, geographic information systems, and modeling have combined to produce a virtual explosion of growth in ecological investigations and applications that are explicitly spatial and temporal. Of all remotely sensed data, those acquired by landsat sensors have played the most pivotal role in spatial and temporal scaling. Modern terrestrial ecology relies on...
Noninvasive imaging of bone microarchitecture
Patsch, Janina M.; Burghardt, Andrew J.; Kazakia, Galateia; Majumdar, Sharmila
2015-01-01
The noninvasive quantification of peripheral compartment-specific bone microarchitecture is feasible with high-resolution peripheral quantitative computed tomography (HR-pQCT) and high-resolution magnetic resonance imaging (HR-MRI). In addition to classic morphometric indices, both techniques provide a suitable basis for virtual biomechanical testing using finite element (FE) analyses. Methodical limitations, morphometric parameter definition, and motion artifacts have to be considered to achieve optimal data interpretation from imaging studies. With increasing availability of in vivo high-resolution bone imaging techniques, special emphasis should be put on quality control including multicenter, cross-site validations. Importantly, conclusions from interventional studies investigating the effects of antiosteoporotic drugs on bone microarchitecture should be drawn with care, ideally involving imaging scientists, translational researchers, and clinicians. PMID:22172043
Lin, Yanping; Chen, Huajiang; Yu, Dedong; Zhang, Ying; Yuan, Wen
2017-01-01
Bone drilling simulators with virtual and haptic feedback provide a safe, cost-effective and repeatable alternative to traditional surgical training methods. To develop such a simulator, accurate haptic rendering based on a force model is required to feedback bone drilling forces based on user input. Current predictive bone drilling force models based on bovine bones with various drilling conditions and parameters are not representative of the bone drilling process in bone surgery. The objective of this study was to provide a bone drilling force model for haptic rendering based on calibration and validation experiments in fresh cadaveric bones with different bone densities. Using a commonly used drill bit geometry (2 mm diameter), feed rates (20-60 mm/min) and spindle speeds (4000-6000 rpm) in orthognathic surgeries, the bone drilling forces of specimens from two groups were measured and the calibration coefficients of the specific normal and frictional pressures were determined. The comparison of the predicted forces and the measured forces from validation experiments with a large range of feed rates and spindle speeds demonstrates that the proposed bone drilling forces can predict the trends and average forces well. The presented bone drilling force model can be used for haptic rendering in surgical simulators.
Hanken, Henning; Schablowsky, Clemens; Smeets, Ralf; Heiland, Max; Sehner, Susanne; Riecke, Björn; Nourwali, Ibrahim; Vorwig, Oliver; Gröbe, Alexander; Al-Dam, Ahmed
2015-04-01
The reconstruction of large facial bony defects using microvascular transplants requires extensive surgery to achieve full rehabilitation of form and function. The purpose of this study is to measure the agreement between virtual plans and the actual results of maxillofacial reconstruction. This retrospective cohort study included 30 subjects receiving maxillofacial reconstruction with a preoperative virtual planning. Parameters including defect size, position, angle and volume of the transplanted segments were compared between the virtual plan and the real outcome using paired t test. A total of 63 bone segments were transplanted. The mean differences between the virtual planning and the postoperative situation were for the defect sizes 1.17 mm (95 % confidence interval (CI) (-.21 to 2.56 mm); p = 0.094), for the resection planes 1.69 mm (95 % CI (1.26-2.11); p = 0.033) and 10.16° (95 % CI (8.36°-11.96°); p < 0.001) and for the planes of the donor segments 10.81° (95 % CI (9.44°-12.17°); p < 0.001) The orientation of the segments differed by 6.68° (95 % CI (5.7°-7.66°); p < 0.001) from the virtual plan; the length of the segments differed by -0.12 mm (95 % CI (0.89-0.65 mm); not significant (n.s.)), respectively, while the volume differed by 73.3 % (95 % CI (69.4-77.6 %); p < 0.001). The distance between the transplanted segments and the remaining bone was 1.49 mm (95 % CI (1.24-1.74); p < 0.001) and between the segments 1.49 mm (95 % CI (1.16-1.81); p < 0.001). Virtual plans for mandibular and maxillofacial reconstruction can be realised with excellent match. These highly satisfactory postoperative results are the basis for an optimal functional and aesthetic reconstruction in a single surgical procedure. The technique should be further investigated in larger study populations and should be further improved.
Modifications to a 3D-printed temporal bone model for augmented stapes fixation surgery teaching.
Nguyen, Yann; Mamelle, Elisabeth; De Seta, Daniele; Sterkers, Olivier; Bernardeschi, Daniele; Torres, Renato
2017-07-01
Functional outcomes and complications in otosclerosis surgery are governed by the surgeon's experience. Thus, teaching the procedure to residents to guide them through the learning process as quickly as possible is challenging. Artificial 3D-printed temporal bones are replacing cadaver specimens in many institutions to learn mastoidectomy, but these are not suitable for middle ear surgery training. The goal of this work was to adapt such an artificial temporal bone to aid the teaching of otosclerosis surgery and to evaluate this tool. We have modified a commercially available 3D-printed temporal bone by replacing the incus and stapes of the model with in-house 3D-printed ossicles. The incus could be attached to a 6-axis force sensor. The stapes footplate was fenestrated and attached to a 1-axis force sensor. Six junior surgeons (residents) and seven senior surgeons (fellows or consultants) were enrolled to perform piston prosthesis placement and crimping as performed during otosclerosis surgery. The time required to perform the tasks and the forces applied to the incus and stapes were collected and analyzed. No statistically significant differences were observed between the junior and senior groups for time taken to perform the tasks and the forces applied to the incus during crimping and placement of the prosthesis. However, significantly lower forces were applied to the stapes by the senior surgeons in comparison with the junior surgeons during prosthesis placement (junior vs senior group, 328 ± 202.9 vs 80 ± 99.6 mN, p = 0.008) and during prosthesis crimping (junior vs senior group, 565 ± 233 vs 66 ± 48.6 mN, p = 0.02). We have described a new teaching tool for otosclerosis surgery based on the modification of a 3D-printed temporal bone to implement force sensors on the incus and stapes. This tool could be used as a training tool to help the residents to self-evaluate their progress with recording of objective measurements.
High power microwave generator
Minich, Roger W.
1988-01-01
A device (10) for producing high-powered and coherent microwaves is described. The device comprises an evacuated, cylindrical, and hollow real cathode (20) that is driven to inwardly field emit relativistic electrons. The electrons pass through an internally disposed cylindrical and substantially electron-transparent cylindrical anode (24), proceed toward a cylindrical electron collector electrode (26), and form a cylindrical virtual cathode (32). Microwaves are produced by spatial and temporal oscillations of the cylindrical virtual cathode (32), and by electrons that reflex back and forth between the cylindrical virtual cathode (32) and the cylindrical real cathode (20).
A qualitative and quantitative assessment for a bone marrow harvest simulator.
Machado, Liliane S; Moraes, Ronei M
2009-01-01
Several approaches to perform assessment in training simulators based on virtual reality have been proposed. There are two kinds of assessment methods: offline and online. The main requirements related to online training assessment methodologies applied to virtual reality systems are the low computational complexity and the high accuracy. In the literature it can be found several approaches for general cases which can satisfy such requirements. An inconvenient about those approaches is related to an unsatisfactory solution for specific cases, as in some medical procedures, where there are quantitative and qualitative information available to perform the assessment. In this paper, we present an approach to online training assessment based on a Modified Naive Bayes which can manipulate qualitative and quantitative variables simultaneously. A special medical case was simulated in a bone marrow harvest simulator. The results obtained were satisfactory and evidenced the applicability of the method.
Regenbogen, Christina; Herrmann, Manfred; Fehr, Thorsten
2010-01-01
Studies investigating the effects of violent computer and video game playing have resulted in heterogeneous outcomes. It has been assumed that there is a decreased ability to differentiate between virtuality and reality in people that play these games intensively. FMRI data of a group of young males with (gamers) and without (controls) a history of long-term violent computer game playing experience were obtained during the presentation of computer game and realistic video sequences. In gamers the processing of real violence in contrast to nonviolence produced activation clusters in right inferior frontal, left lingual and superior temporal brain regions. Virtual violence activated a network comprising bilateral inferior frontal, occipital, postcentral, right middle temporal, and left fusiform regions. Control participants showed extended left frontal, insula and superior frontal activations during the processing of real, and posterior activations during the processing of virtual violent scenarios. The data suggest that the ability to differentiate automatically between real and virtual violence has not been diminished by a long-term history of violent video game play, nor have gamers' neural responses to real violence in particular been subject to desensitization processes. However, analyses of individual data indicated that group-related analyses reflect only a small part of actual individual different neural network involvement, suggesting that the consideration of individual learning history is sufficient for the present discussion.
Kimura, Yurika; Kubo, Sachiho; Koda, Hiroko; Shigemoto, Kazuhiro; Sawabe, Motoji; Kitamura, Ken
2013-08-01
Molecular analysis using archival human inner ear specimens is challenging because of the anatomical complexity, long-term fixation, and decalcification. However, this method may provide great benefit for elucidation of otological diseases. Here, we extracted mRNA for RT-PCR from tissues dissected from archival FFPE human inner ears by laser microdissection. Three human temporal bones obtained at autopsy were fixed in formalin, decalcified by EDTA, and embedded in paraffin. The samples were isolated into spiral ligaments, outer hair cells, spiral ganglion cells, and stria vascularis by laser microdissection. RNA was extracted and heat-treated in 10 mM citrate buffer to remove the formalin-derived modification. To identify the sites where COCH and SLC26A5 mRNA were expressed, semi-nested RT-PCR was performed. We also examined how long COCH mRNA could be amplified by semi-nested RT-PCR in archival temporal bone. COCH was expressed in the spiral ligament and stria vascularis. However, SLC26A5 was expressed only in outer hair cells. The maximum base length of COCH mRNA amplified by RT-PCR was 98 bp in 1 case and 123 bp in 2 cases. We detected COCH and SLC26A5 mRNA in specific structures and cells of the inner ear from archival human temporal bone. Our innovative method using laser microdissection and semi-nested RT-PCR should advance future RNA study of human inner ear diseases. Copyright © 2013 Elsevier B.V. All rights reserved.
Vestibular Evoked Myogenic Potentials (VEMP) Can Detect Asymptomatic Saccular Hydrops
Lin, Ming-Yee; Timmer, Ferdinand C. A.; Oriel, Brad S.; Zhou, Guangwei; Guinan, John J.; Kujawa, Sharon G.; Herrmann, Barbara S.; Merchant, Saumil N.; Rauch, Steven D.
2009-01-01
Objective The objective of this study was to explore the useful of vestibular evoked myogenic potential (VEMP) testing for detecting endolymphatic hydrops, especially in the second ear of patients with unilateral Ménière disease (MD). Methods This study was performed at a tertiary care academic medical center. Part I consisted of postmortem temporal bone specimens from the temporal bone collection of the Massachusetts Eye & Ear Infirmary; part II consisted of consecutive consenting adult patients (n = 82) with unilateral MD by American Academy of Otolaryngology–Head and Neck Surgery criteria case histories. Out-come measures consisted of VEMP thresholds in patients and histologic saccular endolymphatic hydrops in postmortem temporal bones. Results Saccular hydrops was observed in the asymptomatic ear in six of 17 (35%) of temporal bones from donors with unilateral MD. Clinic patients with unilateral MD showed elevated mean VEMP thresholds and altered VEMP tuning in their symptomatic ears and, to a lesser degree, in their asymptomatic ears. Specific VEMP frequency and tuning criteria were used to define a “Ménière-like” response. This “Ménière-like” response was seen in 27% of asymptomatic ears of our patients with unilateral MD. Conclusions Bilateral involvement is seen in approximately one third of MD cases. Saccular hydrops appears to precede symptoms in bilateral MD. Changes in VEMP threshold and tuning appear to be sensitive to these structural changes in the saccule. If so, then VEMP may be useful as a detector of asymptomatic saccular hydrops and as a predictor of evolving bilateral MD. PMID:16735912
Thermal effects of endoscopy in a human temporal bone model: Implications for endoscopic ear surgery
Kozin, Elliott D.; Lehmann, Ashton; Carter, Margaret; Hight, Ed; Cohen, Michael; Nakajima, Hideko Heidi; Lee, Daniel J.
2015-01-01
Objective Although the theoretical risk of elevated temperatures during endoscopic ear surgery has been reported previously, neither temperature change nor heat distribution associated with the endoscope has been quantified. In this study, we measure temperature changes during rigid middle ear endoscopy in a human temporal bone model and investigate whether suction can act as a significant cooling mechanism. Study Design Human temporal bone model of endoscopic middle ear surgery. Methods Fresh human temporal bones were maintained at body temperature (~36°C). Temperature fluctuations were measured as a function of 1) distance between the tip of a 3mm 0° Hopkins rod and round window membrane, and 2) intensity of the light source. Infrared imaging determined the thermal gradient. For suction, a #20 French was utilized. Results We found: 1) an endoscope maximally powered by a xenon or LED light source resulted in a rapid temperature elevation up to 46°C within 0.5–1mm from the tip of the endoscope within 30–124 seconds; 2) elevated temperatures occurred up to 8mm from the endoscope tip; and 3) temperature decreased rapidly within 20–88 seconds of turning off the light source or applying suction. Conclusion Our findings have direct implications for avoiding excessive temperature elevation in endoscopic ear surgery. We recommend: 1) using submaximal light intensity, 2) frequent repositioning of the endoscope, and 3) removing the endoscope to allow tissue cooling. Use of suction provides rapid cooling of the middle ear space and may be incorporated in the design of new instrumentation for prolonged dissection. PMID:24604692
Inflammatory Pseudotumor of the Temporal Bone: A Case Series.
Ortlip, Timothy E; Drake, Virginia E; Raghavan, Prashant; Papadimitriou, John C; Porter, Neil C; Eisenman, David J; Hertzano, Ronna
2017-08-01
Inflammatory pseudotumor of the temporal bone is a benign, idiopathic inflammatory process that is locally invasive and a cause of significant morbidity. This study reviews our experience with seven patients and is currently the largest series to date. Retrospective review from January 1, 2014 to January 1, 2016. Single tertiary medical center. There were five male and two female (n = 7) subjects with a diagnosis of temporal bone inflammatory pseudotumor. The mean age at presentation was 41 years old. The most common presenting symptoms were hearing loss (7/7) and headache (4/7). Four patients demonstrated an inflammatory aural polyp. Two patients experienced facial nerve paralysis. Seven patients underwent computed tomography and six underwent magnetic resonance imaging. Corticosteroids and antibiotics were the initial treatment of choice. Five patients also underwent surgery. As adjuvant therapy, two patients received Rituximab, one patient received radiation, and one received mycophenolate mofetil. Clinical courses were followed with focus on symptoms, disease recurrence, duration, and treatment. Mean follow-up was 17.8 months. The primary lesions demonstrated T2 hypo-intensity and enhancement as well as diffuse dural thickening on magnetic resonance imaging in five of six patients. Histopathology demonstrated chronic inflammation in the setting of hyalinized fibrosis (7/7). All the patients are currently symptomatically stable. Inflammatory pseudotumor of the temporal bone can cause devastating effects on neurological function and quality of life. Recognition of characteristic imaging and histopathology can expedite appropriate treatment. Patients may require chronic steroid therapy. Adjunctive therapy with radiation and immuno-modulation are currently being explored.
Reyes-Centeno, Hugo; Ghirotto, Silvia; Harvati, Katerina
2017-01-01
In modern humans, the significant correlation between neutral genetic loci and cranial anatomy suggests that the cranium preserves a population history signature. However, there is disagreement on whether certain parts of the cranium preserve this signature to a greater degree than other parts. It is also unclear how different quantitative measures of phenotype affect the association of genetic variation and anatomy. Here, we revisit these matters by testing the correlation of genetic distances and various phenotypic distances for ten modern human populations. Geometric morphometric shape data from the crania of adult individuals (n = 224) are used to calculate phenotypic P ST , Procrustes, and Mahalanobis distances. We calculate their correlation to neutral genetic distances, F ST , derived from single nucleotide polymorphisms (SNPs). We subset the cranial data into landmark configurations that include the neurocranium, the face, and the temporal bone in order to evaluate whether these cranial regions are differentially correlated to neutral genetic variation. Our results show that P ST , Mahalanobis, and Procrustes distances are correlated with F ST distances to varying degrees. They indicate that overall cranial shape is significantly correlated with neutral genetic variation. Of the component parts examined, P ST distances for both the temporal bone and the face have a stronger association with F ST distances than the neurocranium. When controlling for population divergence time, only the whole cranium and the temporal bone have a statistically significant association with F ST distances. Our results confirm that the cranium, as a whole, and the temporal bone can be used to reconstruct modern human population history. © 2016 Wiley Periodicals, Inc.
Assessing stapes piston position using computed tomography: a cadaveric study.
Hahn, Yoav; Diaz, Rodney; Hartman, Jonathan; Bobinski, Matthew; Brodie, Hilary
2009-02-01
Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.
Realistic Data-Driven Traffic Flow Animation Using Texture Synthesis.
Chao, Qianwen; Deng, Zhigang; Ren, Jiaping; Ye, Qianqian; Jin, Xiaogang
2018-02-01
We present a novel data-driven approach to populate virtual road networks with realistic traffic flows. Specifically, given a limited set of vehicle trajectories as the input samples, our approach first synthesizes a large set of vehicle trajectories. By taking the spatio-temporal information of traffic flows as a 2D texture, the generation of new traffic flows can be formulated as a texture synthesis process, which is solved by minimizing a newly developed traffic texture energy. The synthesized output captures the spatio-temporal dynamics of the input traffic flows, and the vehicle interactions in it strictly follow traffic rules. After that, we position the synthesized vehicle trajectory data to virtual road networks using a cage-based registration scheme, where a few traffic-specific constraints are enforced to maintain each vehicle's original spatial location and synchronize its motion in concert with its neighboring vehicles. Our approach is intuitive to control and scalable to the complexity of virtual road networks. We validated our approach through many experiments and paired comparison user studies.
NASA Astrophysics Data System (ADS)
Ho, Wan Ching; Dautenhahn, Kerstin; Nehaniv, Chrystopher
2008-03-01
In this paper, we discuss the concept of autobiographic agent and how memory may extend an agent's temporal horizon and increase its adaptability. These concepts are applied to an implementation of a scenario where agents are interacting in a complex virtual artificial life environment. We present computational memory architectures for autobiographic virtual agents that enable agents to retrieve meaningful information from their dynamic memories which increases their adaptation and survival in the environment. The design of the memory architectures, the agents, and the virtual environment are described in detail. Next, a series of experimental studies and their results are presented which show the adaptive advantage of autobiographic memory, i.e. from remembering significant experiences. Also, in a multi-agent scenario where agents can communicate via stories based on their autobiographic memory, it is found that new adaptive behaviours can emerge from an individual's reinterpretation of experiences received from other agents whereby higher communication frequency yields better group performance. An interface is described that visualises the memory contents of an agent. From an observer perspective, the agents' behaviours can be understood as individually structured, and temporally grounded, and, with the communication of experience, can be seen to rely on emergent mixed narrative reconstructions combining the experiences of several agents. This research leads to insights into how bottom-up story-telling and autobiographic reconstruction in autonomous, adaptive agents allow temporally grounded behaviour to emerge. The article concludes with a discussion of possible implications of this research direction for future autobiographic, narrative agents.
Vrionis, F D; Robertson, J H; Foley, K T; Gardner, G
1997-01-01
Approaches through the middle cranial fossa directed at reaching the internal auditory canal (IAC) invariably employ exposure of the geniculate ganglion, the superior semicircular canal (SSC) or the epitympanum. This involves risk to the facial nerve and hearing apparatus. To minimize this risk, we conducted a laboratory study on 9 cadaver temporal bones by using an image-interactive guidance system (StealthStation) to provide topographic orientation in the middle fossa approach. Surface anatomic fiducials such as the umbo of the tympanic membrane, Henle's spine, the root of the zygoma and various sutures were used as fiducials for registration of CT-images of the temporal bone. Accurate localization of the IAC was achieved in every specimen. Mean target localization error varied from 1.20 to 1.38 mm for critical structures in the temporal bone such as the apex of the cochlea, crus commune, ampula of the SSC and facial hiatus. Our results suggest that frameless stereotaxy may be used as an alternative to current methods in localizing the IAC in patients with small vestibular schwannomas or intractable vertigo undergoing middle fossa surgery.
Optical coherence tomography as a guide for cochlear implant surgery?
NASA Astrophysics Data System (ADS)
Just, T.; Lankenau, E.; Hüttmann, G.; Pau, H. W.
2008-02-01
To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal bone preparations, in which the cochleostomy was performed leaving the membranous labyrinth and the fluid-filled inner ear intact. A specially equipped operating microscope with integrated OCT prototype was used. Spectral-domain (SD)-OCT was used for all investigations. On all scans, OCT supplied information about inner ear structures, such as scala tympani, scala vestibuli while the membranous labyrinth was still intact. In the fresh temporal bone the scala media, basilar membrane and the Reissner's membrane were identified. This OCT study clearly documents the possibility to identify inner ear structures, especially the scala tympani without opening its enveloping membranes. These findings may have an impact on cochlear implant surgery, especially as an orientation guide to localize the scala tympani precisely before opening the fluid filled inner ear.
A collaborative molecular modeling environment using a virtual tunneling service.
Lee, Jun; Kim, Jee-In; Kang, Lin-Woo
2012-01-01
Collaborative researches of three-dimensional molecular modeling can be limited by different time zones and locations. A networked virtual environment can be utilized to overcome the problem caused by the temporal and spatial differences. However, traditional approaches did not sufficiently consider integration of different computing environments, which were characterized by types of applications, roles of users, and so on. We propose a collaborative molecular modeling environment to integrate different molecule modeling systems using a virtual tunneling service. We integrated Co-Coot, which is a collaborative crystallographic object-oriented toolkit, with VRMMS, which is a virtual reality molecular modeling system, through a collaborative tunneling system. The proposed system showed reliable quantitative and qualitative results through pilot experiments.
Comparison of cadaveric and isomorphic three-dimensional printed models in temporal bone education.
Hochman, Jordan B; Rhodes, Charlotte; Wong, Dana; Kraut, Jay; Pisa, Justyn; Unger, Bertram
2015-10-01
Current three-dimensional (3D) printed simulations are complicated by insufficient void spaces and inconsistent density. We describe a novel simulation with focus on internal anatomic fidelity and evaluate against template/identical cadaveric education. Research ethics board-approved prospective cohort study. Generation of a 3D printed temporal bone was performed using a proprietary algorithm that deconstructs the digital model into slices prior to printing. This supplemental process facilitates removal of residual material from air-containing spaces and permits requisite infiltrative access to the all regions of the model. Ten otolaryngology trainees dissected a cadaveric temporal bone (CTB) followed by a matched/isomorphic 3D printed bone model (PBM), based on derivative micro-computed tomography data. Participants rated 1) physical characteristics, 2) specific anatomic constructs, 3) usefulness in skill development, and 4) perceived educational value. The survey instrument employed a seven-point Likert scale. Trainees felt physical characteristics of the PBM were quite similar to CTB, with highly ranked cortical (5.5 ± 1.5) and trabecular (5.2 ± 1.3) bone drill quality. The overall model was considered comparable to CTB (5.9 ± 0.74), with respectable air cell reproduction (6.1 ± 1.1). Internal constructs were rated as satisfactory (range, 4.9-6.2). The simulation was considered a beneficial training tool for all types of mastoidectomy (range, 5.9-6.6), posterior tympanotomy (6.5 ± 0.71), and skull base approaches (range, 6-6.5). Participants believed the model to be an effective training instrument (6.7 ± 0.68), which should be incorporated into the temporal bone lab (7.0 ± 0.0). The PBM was thought to improve confidence (6.7 ± 0.68) and operative performance (6.7 ± 0.48). Study participants found the PBM to be an effective platform that compared favorably to CTB. The model was considered a valuable adjunctive training tool with both realistic mechanical and visual character. NA © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
NASA Astrophysics Data System (ADS)
Ciunel, St.; Tica, B.
2016-08-01
The paper presents the studies made on a similar biomechanical system composed by neck, head and thorax bones. The models were defined in a CAD environment which includes Adams algorithm for dynamic simulations. The virtual models and the entire morphology were obtained starting with CT images made on a living human subject. The main movements analyzed were: axial rotation (left-right), lateral bending (left-right) and flexion- extension movement. After simulation was obtained the entire biomechanical behavior based on data tables or diagrams. That virtual model composed by neck and head can be included in complex system (as a car system) and supposed to several impact simulations (virtual crash tests). Also, our research team built main components of a testing device for dummy car crash neck-head system using anatomical data.
Reduced functional loads alter the physical characteristics of the bone-PDL-cementum complex
Niver, Eric L.; Leong, Narita; Greene, Janelle; Curtis, Donald; Ryder, Mark I.; Ho, Sunita P.
2011-01-01
Background Adaptive properties of the bone-PDL-tooth complex have been identified by changing the magnitude of functional loads using small-scale animal models such as rodents. Reported adaptive responses as a result of lower loads due to softer diet include decreased muscle development, change in structure-function relationship of the cranium, narrowed PDL-space, changes in mineral level of the cortical bone and alveolar jaw bone, and glycosaminoglycans of the alveolar bone. However, the adaptive role of the dynamic bone-PDL-cementum complex due to prolonged reduced loads has not been fully explained to date, especially with regards to concurrent adaptations of bone, PDL and cementum. Hence, the temporal effect of reduced functional loads on physical characteristics such as morphology and mechanical properties, and mineral profiles of the bone-periodontal ligament (PDL)-cementum complex using a rat model was investigated. Materials and Methods Two groups of six-week-old male Sprague-Dawley rats were fed nutritionally identical food with a stiffness range of 127–158N/mm for hard pellet or 0.32–0.47N/mm for soft powder forms. Spatio-temporal adaptation of the bone-PDL-cementum complex was identified by mapping changes in: 1) PDL-collagen orientation and birefringence using polarized light microscopy, bone and cementum adaptation using histochemistry, and bone and cementum morphology using micro X-ray computed tomography, 2) mineral profiles of the PDL-cementum and PDL-bone interfaces by X-ray attenuation, and 3) microhardness of bone and cementum by microindentation of specimens at ages six, eight, twelve, and fifteen weeks. Results Reduced functional loads over prolonged time resulted in 1) altered PDL orientation and decreased PDL collagen birefringence indicating decreased PDL turnover rate and decreased apical cementum resorption; 2) a gradual increase in X-ray attenuation, owing to mineral differences, at the PDL-bone and PDL-cementum interfaces without significant differences in the gradients for either group; 3) significantly (p<0.05) lower microhardness of alveolar bone (0.93±0.16 GPa) and secondary cementum (0.803±0.13 GPa) compared to the higher load group (1.10±0.17 GPa and 0.940±0.15 GPa respectively) at fifteen weeks indicating a temporal effect of loads on local mineralization of bone and cementum. Conclusions Based on the results from this study, the effect of reduced functional loads for a prolonged time could differentially affect morphology and mechanical properties, and mineral variations and of the local load-bearing sites in a bone-PDL-cementum complex. These observed local changes in turn could help explain the overall biomechanical function and adaptations of the tooth-bone joint. From a clinical translation perspective, our study provides an insight into modulation of load on the complex for improved tooth function during periodontal disease, and/or orthodontic and prosthodontic treatments. PMID:21848615
Radionuclide bone imaging: an illustrative review.
Love, Charito; Din, Anabella S; Tomas, Maria B; Kalapparambath, Tomy P; Palestro, Christopher J
2003-01-01
Bone scintigraphy with technetium-99m-labeled diphosphonates is one of the most frequently performed of all radionuclide procedures. Radionuclide bone imaging is not specific, but its excellent sensitivity makes it useful in screening for many pathologic conditions. Moreover, some conditions that are not clearly depicted on anatomic images can be diagnosed with bone scintigraphy. Bone metastases usually appear as multiple foci of increased activity, although they occasionally manifest as areas of decreased uptake. Traumatic processes can often be detected, even when radiographic findings are negative. Most fractures are scintigraphically detectable within 24 hours, although in elderly patients with osteopenia, further imaging at a later time is sometimes indicated. Athletic individuals are prone to musculoskeletal trauma, and radionuclide bone imaging is useful for identifying pathologic conditions such as plantar fasciitis, stress fractures, "shin splints," and spondylolysis, for which radiographs may be nondiagnostic. A combination of focal hyperperfusion, focal hyperemia, and focally increased bone uptake is virtually diagnostic for osteomyelitis in patients with nonviolated bone. Bone scintigraphy is also useful for evaluating disease extent in Paget disease and for localizing avascular necrosis in patients with negative radiographs. Radionuclide bone imaging will likely remain a popular and important imaging modality for years to come. Copyright RSNA, 2003
Thali, Michael J; Taubenreuther, Ulrike; Karolczak, Marek; Braun, Marcel; Brueschweiler, Walter; Kalender, Willi A; Dirnhofer, Richard
2003-11-01
When a knife is stabbed in bone, it leaves an impression in the bone. The characteristics (shape, size, etc.) may indicate the type of tool used to produce the patterned injury in bone. Until now it has been impossible in forensic sciences to document such damage precisely and non-destructively. Micro-computed tomography (Micro-CT) offers an opportunity to analyze patterned injuries of tool marks made in bone. Using high-resolution Micro-CT and computer software, detailed analysis of three-dimensional (3D) architecture has recently become feasible and allows microstructural 3D bone information to be collected. With adequate viewing software, data from 2D slice of an arbitrary plane can be extracted from 3D datasets. Using such software as a "digital virtual knife," the examiner can interactively section and analyze the 3D sample. Analysis of the bone injury revealed that Micro-CT provides an opportunity to correlate a bone injury to an injury-causing instrument. Even broken knife tips can be graphically and non-destructively assigned to a suspect weapon.
Bardsley, Katie; Kwarciak, Agnieska; Freeman, Christine; Brook, Ian; Hatton, Paul; Crawford, Aileen
2017-01-01
The regeneration of large bone defects remains clinically challenging. The aim of our study was to use a rat model to use nasal chondrocytes to engineer a hypertrophic cartilage tissue which could be remodelled into bone in vivo by endochondral ossification. Primary adult rat nasal chondrocytes were isolated from the nasal septum, the cell numbers expanded in monolayer culture and the cells cultured in vitro on polyglycolic acid scaffolds in chondrogenic medium for culture periods of 5-10 weeks. Hypertrophic differentiation was assessed by determining the temporal expression of key marker genes and proteins involved in hypertrophic cartilage formation. The temporal changes in the genes measured reflected the temporal changes observed in the growth plate. Collagen II gene expression increased 6 fold by day 7 and was then significantly downregulated from day 14 onwards. Conversely, collagen X gene expression was detectable by day 14 and increased 100-fold by day 35. The temporal increase in collagen X expression was mirrored by increases in alkaline phosphatase gene expression which also was detectable by day 14 with a 30-fold increase in gene expression by day 35. Histological and immunohistochemical analysis of the engineered constructs showed increased chondrocyte cell volume (31-45 μm), deposition of collagen X in the extracellular matrix and expression of alkaline phosphatase activity. However, no cartilage mineralisation was observed in in vitro culture of up to 10 weeks. On subcutaneous implantation of the hypertrophic engineered constructs, the grafts became vascularised, cartilage mineralisation occurred and loss of the proteoglycan in the matrix was observed. Implantation of the hypertrophic engineered constructs into a rat cranial defect resulted in angiogenesis, mineralisation and remodelling of the cartilage tissue into bone. Micro-CT analysis indicated that defects which received the engineered hypertrophic constructs showed 38.48% in bone volume compared to 7.01% in the control defects. Development of tissue engineered hypertrophic cartilage to use as a bone graft substitute is an exciting development in regenerative medicine. This is a proof of principal study demonstrating the potential of nasal chondrocytes to engineer hypertrophic cartilage which will remodel into bone on in vivo transplantation. This approach to making engineered hypertrophic cartilage grafts could form the basis of a new potential future clinical treatment for maxillofacial reconstruction. Copyright © 2016. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
Schleich, Jean-Marc; Dillenseger, Jean-Louis; Houyel, Lucile; Almange, Claude; Anderson, Robert H.
2009-01-01
Learning embryology remains difficult, since it requires understanding of many complex phenomena. The temporal evolution of developmental events has classically been illustrated using cartoons, which create difficulty in linking spatial and temporal aspects, such correlation being the keystone of descriptive embryology. We synthesized the…
Different clinical presentation and management of temporal bone fibrous dysplasia in children.
Mierzwiński, Józef; Kosowska, Justyna; Tyra, Justyna; Haber, Karolina; Drela, Maria; Paczkowski, Dariusz; Burduk, Paweł
2018-01-15
Fibrous dysplasia is a slowly progressive benign fibro-osseous disorder that involves one or multiple bones with a unilateral distribution in most cases. It is a lesion of unknown etiology, uncertain pathogenesis, and diverse histopathology. Temporal bone involvement is the least frequently reported type, especially in children. We reviewed available articles regarding fibrous dysplasia with temporal bone involvement in children and added four patients aged 7 to 17 years who were diagnosed and treated in our institution from 2006 to 2017. The patients' clinical picture comprised head deformity, external canal stenosis, headache, progressive conductive and/or sensorineural hearing loss, tinnitus, and sudden deafness. Two patients had experienced severe episodic vertigo with nausea and vomiting. Two were referred to us with external canal obstruction and secondary cholesteatoma formation with broad middle ear destruction. One was diagnosed with acute mastoiditis and intracranial complications. Optimal management of fibrous dysplasia is unclear and can be challenging, especially in children. In our two patients with disease expansion and involvement of important structures, surgical treatment was abandoned and a "wait-and-scan" policy was applied. The other two were qualified for surgical treatment. One patient underwent two surgeries: modified lateral petrosectomy (canal left open) with pathological tissue removal, cavity obliteration, and subsequent tympanoplasty. Another patient with extensive destruction of the left temporal bone underwent canal wall down mastoidectomy with perisinus abscess drainage and revision 12 months later. Tympanoplasty was unsatisfactory in both patients because of slow progression of the middle ear pathology. None of our patients underwent pharmacological treatment. In younger patients, observation and a "wait-and-scan" protocol is relevant until significant function, or cosmetic deficits are obvious. Surgery is not preferred and should be delayed until puberty because fibrous dysplasia has a tendency to stabilize after adolescence. In patients with severe symptoms medical treatment can be implemented, but safety of this treatment in children remain controversial.
Evaluating cochlear implant trauma to the scala vestibuli.
Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W
2005-04-01
Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.
Hydroxyapatite granules used in the obliteration of mastoid cavities in rats.
Hamerschmidt, Rogério; Santos, Rafael Francisco dos; Araújo, João Cândido; Stahlke, Henrique Jorge; Agulham, Miguel Angelo; Moreira, Ana Tereza Ramos; Mocellin, Marcos
2011-06-01
Prospective experimental study in which we created a bony defect in the mastoids of rats and filled it up with hydroxyapatite to evaluate bone regeneration, to solve the problems of open cavities after mastoidectomies that frequently present with otorrhea, infection, granulation tissue and hearing loss. The aim was to evaluate bone regeneration in defects created in the mastoids of rats, using hydroxyapatite, to see how much of the cavity we could reduce. Twelve rats Wistar-Furth were used. A 0.5 x 0.5 cm bone defect was created in both temporal bones of the rats, and filled with 15 micrograms of hydroxyapatite. The left side was used as control. The animals were slaughtered 40 days afterwards and histology analyses were carried out. In the hydroxyapatite group, the new bone growth involved an area of 68.53% of the total; and in the control group it was only of 15.97%. It was observed a very good hydroxyapatite integration to the temporal bone in this experimental model. The microscopic results were superior with the use of hydroxyapatite when compared to the control group. It is a safe method and easy to apply to solve the problems of open cavities with chronic discharge and difficult to clean.
Iizuka, H
1990-11-01
Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.
Kuo, Hsu-Chan; Lee, Chun-Chia; Chiou, Wen-Bin
2016-02-01
The tendency to discount larger future benefits in favor of smaller immediate gains (i.e., temporal discounting) is relevant to the issue of obesity. Successful weight loss requires individuals to sacrifice immediate culinary pleasures in favor of future health gains. Based on the notion that increasing the vividness of one's future self may mitigate temporal discounting and promote the ability to delay gratification, we examined whether viewing one's weight-reduced self (i.e., the ideal self) in a virtual environment can decrease temporal discounting and lead to better regulation of dietary practices. Seventy-six undergraduates who had reported an intention to lose weight were recruited to participate in a laboratory experiment and were randomly assigned to interact with either the weight-reduced self (experimental condition) or the present self (control condition) by looking into a dressing mirror in a virtual fitting room. A temporal-discounting task and a taste test were subsequently administered. Results showed that, compared with control participants, participants who viewed their weight-reduced avatars ate less ice cream in a taste test and were more likely to choose a sugar-free drink as a reward. The discounting rate mediated the association between the avatar manipulation and the amount of ice cream eaten in the subsequent taste test. Overall, our findings suggest that a computer-generated image of one's weight-reduced self may assist in resisting impulses that promote immediate gratification over delayed benefits. This research provides a new approach for controlling impulsive behavior such as dietary regulation and weight control.
Rodríguez-Tizcareño, Mario H; Barajas, Lizbeth; Pérez-Gásque, Marisol; Gómez, Salvador
2012-06-01
This report presents a protocol used to transfer the virtual treatment plan data to the surgical and prosthetic reality and its clinical application, bone site augmentation with computer-custom milled bovine bone graft blocks to their ideal architecture form, implant insertion based on image-guided stent fabrication, and the restorative manufacturing process through computed tomography-based software programs and navigation systems and the computer-aided design and manufacturing techniques for the treatment of the edentulous maxilla.
Lin, Hsin-Hon; Peng, Shin-Lei; Wu, Jay; Shih, Tian-Yu; Chuang, Keh-Shih; Shih, Cheng-Ting
2017-05-01
Osteoporosis is a disease characterized by a degradation of bone structures. Various methods have been developed to diagnose osteoporosis by measuring bone mineral density (BMD) of patients. However, BMDs from these methods were not equivalent and were incomparable. In addition, partial volume effect introduces errors in estimating bone volume from computed tomography (CT) images using image segmentation. In this study, a two-compartment model (TCM) was proposed to calculate bone volume fraction (BV/TV) and BMD from CT images. The TCM considers bones to be composed of two sub-materials. Various equivalent BV/TV and BMD can be calculated by applying corresponding sub-material pairs in the TCM. In contrast to image segmentation, the TCM prevented the influence of the partial volume effect by calculating the volume percentage of sub-material in each image voxel. Validations of the TCM were performed using bone-equivalent uniform phantoms, a 3D-printed trabecular-structural phantom, a temporal bone flap, and abdominal CT images. By using the TCM, the calculated BV/TVs of the uniform phantoms were within percent errors of ±2%; the percent errors of the structural volumes with various CT slice thickness were below 9%; the volume of the temporal bone flap was close to that from micro-CT images with a percent error of 4.1%. No significant difference (p >0.01) was found between the areal BMD of lumbar vertebrae calculated using the TCM and measured using dual-energy X-ray absorptiometry. In conclusion, the proposed TCM could be applied to diagnose osteoporosis, while providing a basis for comparing various measurement methods.
Maniu, Alma Aurelia; Harabagiu, Oana; Damian, Laura Otilia; Ştefănescu, Eugen HoraŢiu; FănuŢă, Bogdan Marius; Cătană, Andreea; Mogoantă, Carmen Aurelia
2016-01-01
Several systemic diseases, including granulomatous and infectious processes, tumors, bone disorders, collagen-vascular and other autoimmune diseases may involve the middle ear and temporal bone. These diseases are difficult to diagnose when symptoms mimic acute otomastoiditis. The present report describes our experience with three such cases initially misdiagnosed. Their predominating symptoms were otological with mastoiditis, hearing loss, and subsequently facial nerve palsy. The cases were considered an emergency and the patients underwent tympanomastoidectomy, under the suspicion of otitis media with cholesteatoma, in order to remove a possible abscess and to decompress the facial nerve. The common features were the presence of severe granulation tissue filling the mastoid cavity and middle ear during surgery, without cholesteatoma. The definitive diagnoses was made by means of biopsy of the granulation tissue from the middle ear, revealing granulomatosis with polyangiitis (formerly known as Wegener's granulomatosis) in one case, middle ear tuberculosis and diffuse large B-cell lymphoma respectively. After specific associated therapy facial nerve functions improved, and atypical inflammatory states of the ear resolved. As a group, systemic diseases of the middle ear and temporal bone are uncommon, but aggressive lesions. After analyzing these cases and reviewing the literature, we would like to stress upon the importance of microscopic examination of the affected tissue, required for an accurate diagnosis and effective treatment.
[Pregnancy and lactation are not risk factors for osteoporosis or fractures].
Karlsson, Magnus K; Ahlborg, Henrik G; Karlsson, Caroline
Observational and case control studies infer that a pregnancy and a period of lactation are followed by loss in bone mass of up to 5%. The reason for this loss is virtually impossible to conclude as so many factors known to influence the bone mass undergo changes during a pregnancy and lactation. The increased calcium demand, changed nutritional habits, reduced smoking and alcohol consumption seen in many women during these periods, the changes in body weight and fat content, the changed level of physical activity and the changed levels of hormones with potential to influence the bone metabolism could all influence the bone mass. Most studies also report that the deficit in "bone mass" normalises after weaning. Multiple pregnancies and long total duration of lactation can not be regarded as risk factors for osteoporosis and fragility fractures as most reports indicate that women with multiple pregnancies have similar or higher bone mass and similar or lower fracture incidence than their peers with no children.
Pettway, Glenda J; Schneider, Abraham; Koh, Amy J; Widjaja, Effendi; Morris, Michael D; Meganck, Jeffrey A; Goldstein, Steven A; McCauley, Laurie K
2005-06-01
PTH is in clinical use for the treatment of osteoporosis and is under intensive investigation for its potential in applications of tissue engineering, fracture healing, and implant integration. However, the mechanisms of its action to stimulate bone formation are still unclear. A novel bone tissue engineering model was used to elucidate basic mechanisms of PTH anabolic actions. Ectopic ossicles containing cortical bone, trabecular bone, and a hematopoietic marrow were generated from implanted bone marrow stromal cells (BMSC). One week after implantation, nude mice were administered PTH or vehicle for 1 week (group 1), 3 weeks (group 2), or 7 weeks (group 3). Another group was also treated for 3 weeks, initiated 12 weeks after implantation (group 4). Micro-radiography and histomorphometry revealed increased marrow cellularity in group 1 PTH-treated ossicles, increased bone in group 2 PTH-treated ossicles, and similar amounts of bone in both group 3 and 4 ossicles regardless of treatment. Incidence of phosphate mineral and phosphate mineral to hydroxyproline ratio via Raman spectroscopy were significantly higher after 3 weeks versus 1 week of PTH treatment, but there was no difference between PTH- and vehicle-treated ossicles. Early events of PTH action in group 1 ossicles and the effects of a single injection of PTH on 1- and 2-week-old ossicles were evaluated by Northern blot analysis. Osteocalcin (OC) mRNA was increased after 1 week of intermittent PTH treatment in ossicles and calvaria but an acute injection did not alter OC mRNA. In contrast, a single injection of PTH increased matrix gamma-carboxyglutamic acid protein (MGP) mRNA in 2-week-old ossicles. Differential and temporal-dependent effects of PTH on OC and MGP suggest at the molecular level, that PTH acts to inhibit osteoblast mineralization. However, this does not translate into tissue level alterations. These data indicate that anabolic actions of PTH in ectopic ossicles are temporally dependent on the BMSC implanted and suggest that cell implantation strategies are particularly responsive to PTH.
Liu, Yu-Hsi; Chang, Kuo-Ping
2016-04-01
Fibrous dysplasia is a slowly progressive benign fibro-osseous disease, rarely occurring in temporal bones. In these cases, most bony lesions developed from the bony part of the external auditory canals, causing otalgia, hearing impairment, otorrhea, and ear hygiene blockade and probably leading to secondary cholesteatoma. We presented the medical history of a 24-year-old woman with temporal monostotic fibrous dysplasia with secondary cholesteatoma. The initial presentation was unilateral conductive hearing loss. A hard external canal tumor contributing to canal stenosis and a near-absent tympanic membrane were found. Canaloplasty and type I tympanoplasty were performed, but the symptoms recurred after 5 years. She received canal wall down tympanomastoidectomy with ossciculoplasty at the second time, and secondary cholesteatoma in the middle ear was diagnosed. Fifteen years later, left otorrhea recurred again and transcanal endoscopic surgery was performed for middle ear clearance. Currently, revision surgeries provide a stable auditory condition, but her monostotic temporal fibrous dysplasia is still in place.
Sorensen, Mads Solvsten; Mosegaard, Jesper; Trier, Peter
2009-06-01
Existing virtual simulators for middle ear surgery are based on 3-dimensional (3D) models from computed tomographic or magnetic resonance imaging data in which image quality is limited by the lack of detail (maximum, approximately 50 voxels/mm3), natural color, and texture of the source material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume rendered as a 3D model of high-fidelity, true color, and great anatomic detail and realism of the surgically relevant structures. A haptic drilling model was developed for surgical interaction with the 3D model. Realistic visualization in high-fidelity (approximately 125 voxels/mm3) and true color, 2D, or optional anaglyph stereoscopic 3D was achieved on a standard Core 2 Duo personal computer with a GeForce 8,800 GTX graphics card, and surgical interaction was provided through a relatively inexpensive (approximately $2,500) Phantom Omni haptic 3D pointing device. This prototype is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic membrane, dura, and cholesteatomas-features some of which are not possible with computed tomographic-/magnetic resonance imaging-based systems.
Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo; Aoki, Ikuo
2003-12-01
The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 degrees) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm3. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in visualizing the enhancement of small structures in the temporal bone; however, enhancement of the cochlear fluid space could not be visualized even with 3D rIR, triple-dose contrast, and dedicated coils at 1.5 T.
Hsu, Benjumin; Seibel, Markus J; Cumming, Robert G; Blyth, Fiona M; Naganathan, Vasi; Bleicher, Kerrin; Le Couteur, David G; Waite, Louise M; Handelsman, David J
2016-12-01
This study aimed to examine progressive temporal relationships between changes in major reproductive hormones across three waves of a cohort study of older men and (1) changes in bone mineral density (BMD) and (2) incident fractures (any, hip or non-vertebral) over an average of 6 years of follow-up. The CHAMP cohort of men aged 70 years and older were assessed at baseline (2005 to 2007, n = 1705), 2-year follow-up (n = 1367), and 5-year follow-up (n = 958). Serum testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and estrone (E1) (by liquid chromatography-tandem mass spectrometry [LC-MS/MS]), and sex hormone-binding globulin (SHBG), luteinizing hormone (LH), and follicle-stimulating hormone (FSH) (by immunoassay) were measured at all time-points, whereas free testosterone (cFT) was calculated using a well-validated formula. Hip BMD was measured by dual-energy X-ray absorptiometry (DXA) at all three time-points, and fracture data were verified radiographically. Statistical modeling was done using general estimating equations (GEEs). For total hip BMD, univariable analyses revealed inverse associations with temporal changes in serum SHBG, FSH, and LH and positive associations for serum E1 and cFT across the three time-points. In models adjusted for multiple covariables, serum SHBG (β = -0.029), FSH (β = -0.065), LH (β = -0.049), E1 (β = 0.019), and cFT (β = 0.033) remained significantly associated with hip BMD. However for femoral neck BMD, only FSH (β = -0.048) and LH (β = -0.036) remained associated in multivariable-adjusted models. Temporal change in serum SHBG, but not T, E2, or other hormonal variables, was significantly associated with any, nonvertebral or hip fracture incidence in univariable analyses. In multivariable-adjusted models, temporal increase in serum SHBG over time remained associated with any fracture (β = 0.060) and hip fracture (β = 0.041) incidence, but not nonvertebral fracture incidence. These data indicate that a progressive increase in circulating SHBG over time predicts bone loss and fracture risk in older men. Further studies are warranted to further characterize changes in circulating SHBG as a mechanism and/or biomarker of bone health during male ageing. © 2016 American Society for Bone and Mineral Research. © 2016 American Society for Bone and Mineral Research.
Bathla, Meeta; Doshi, Hiren; Kansara, Atul
2018-03-01
Role of high resolution computerized tomography (HRCT) of temporal bone is established in cases of atticoantral chronic suppurative otitis media (CSOM) with intracranial complications. Routine use of HRCT in management of patients of atticoantral CSOM without intracranial complications has been an issue of debate. The aim of this study was to evaluate the routine use of HRCT of temporal bone in such cases. This study was a prospective study done at LG hospital, AMC MET Medical College, Ahmedabad to evaluate and compare the temporal bone findings in HRCT and intraoperative findings in 100 patients with atticoantral CSOM. All patients underwent HRCT screening followed by surgical exploration of middle ear cleft. In extent of disease HRCT showed very high sensitivity and specificity for epitympanum (100, 94%) and mesotympanum (98, 98%) areas. It gave valuable information of disease extent in hidden areas like sinus tympani and facial recess of mesotympanum. HRCT satisfactorily delineated malleus and incus erosion but had 75% sensitivity for detecting erosion of stapes suprastructure, though specificity was of 97%. For bony anatomical landmarks HRCT showed very high sensitivity and specificity for detecting erosion of lateral semicircular canal, tegmen tympani and sinus plate. Detection of facial canal erosion on HRCT had moderate sensitivity of 75%. We concluded that routine use of HRCT is justified as a reliable preoperative tool in patients with atticoantral CSOM without intracranial complications and it helps to plan type of surgical intervention. HRCT has limited role to distinguish between granulations and cholesteatoma and also to delineate stapes supra structure and facial nerve canal.
NASA Astrophysics Data System (ADS)
Masud, Salwa F.; Raufer, Stefan; Neely, Stephen T.; Nakajima, Hideko H.
2018-05-01
Superior canal dehiscence (SCD) is a hole in the bony wall of the superior semicircular canal, which can cause various auditory and/or vestibular symptoms and can result in wrong and/or delayed diagnosis. Wideband acoustic immittance (WAI) can potentially distinguish various mechanical middle-ear pathologies as well as inner-ear pathologies non-invasively. We found that in patients, SCD was commonly associated with a narrow-band decrease in power reflectance (PR, derived from WAI) near 1 kHz. Because clinical data has large variation across individual ears and because we do not know the individual "normal" state prior to SCD, we measured WAI in five fresh temporal bone specimens to determine the effects of SCD with respect to the normal state. In temporal bone, we measured PR to assess mechanical changes before and after SCD, as well as to assess the effect of an open or closed middle-ear cavity. After SCD, PR had a consistent decrease between 0.48 and 0.76 kHz, and a slight increase between 1.04 and 1.4 kHz in the open cavity condition. However, in several experiments, we observed low PR around 1 kHz in the normal state before SCD, likely due to the specimen's open middle ear cavity (MEC). Because we see effects of both SCD and open MEC around 1 kHz, some of the SCD effect can be masked by the effect of the MEC in the temporal bone specimens. To compensate for this MEC effect, we estimated the effect of SCD in a closed MEC case, but the effect did not differ significantly from the measured open MEC. This study demonstrates the limitation of temporal bone experiments with open MEC when studying inner-ear lesions with WAI.
Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde
2017-09-01
To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Marcus, Sonya; Whitlow, Christopher T; Koonce, James; Zapadka, Michael E; Chen, Michael Y; Williams, Daniel W; Lewis, Meagan; Evans, Adele K
2014-02-01
Prior studies have associated gross inner ear abnormalities with pediatric sensorineural hearing loss (SNHL) using computed tomography (CT). No studies to date have specifically investigated morphologic inner ear abnormalities involving the contralateral unaffected ear in patients with unilateral SNHL. The purpose of this study is to evaluate contralateral inner ear structures of subjects with unilateral SNHL but no grossly abnormal findings on CT. IRB-approved retrospective analysis of pediatric temporal bone CT scans. 97 temporal bone CT scans, previously interpreted as "normal" based upon previously accepted guidelines by board certified neuroradiologists, were assessed using 12 measurements of the semicircular canals, cochlea and vestibule. The control-group consisted of 72 "normal" temporal bone CTs with underlying SNHL in the subject excluded. The study-group consisted of 25 normal-hearing contralateral temporal bones in subjects with unilateral SNHL. Multivariate analysis of covariance (MANCOVA) was then conducted to evaluate for differences between the study and control group. Cochlea basal turn lumen width was significantly greater in magnitude and central lucency of the lateral semicircular canal bony island was significantly lower in density for audiometrically normal ears of subjects with unilateral SNHL compared to controls. Abnormalities of the inner ear were present in the contralateral audiometrically normal ears of subjects with unilateral SNHL. These data suggest that patients with unilateral SNHL may have a more pervasive disease process that results in abnormalities of both ears. The findings of a cochlea basal turn lumen width disparity >5% from "normal" and/or a lateral semicircular canal bony island central lucency disparity of >5% from "normal" may indicate inherent risk to the contralateral unaffected ear in pediatric patients with unilateral sensorineural hearing loss. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Grotzer, Tina A.; Powell, Megan M.; Derbiszewska, Katarzyna M.; Courter, Caroline J.; Kamarainen, Amy M.; Metcalf, Shari J.; Dede, Christopher J.
2015-01-01
Reasoning about ecosystems includes consideration of causality over temporal and spatial distances; yet learners typically focus on immediate time frames and local contexts. Teaching students to reason beyond these boundaries has met with some success based upon tests that cue students to the types of reasoning required. Virtual worlds offer an…
Niver, E L; Leong, N; Greene, J; Curtis, D; Ryder, M I; Ho, S P
2011-12-01
Adaptive properties of the bone-periodontal ligament-tooth complex have been identified by changing the magnitude of functional loads using small-scale animal models, such as rodents. Reported adaptive responses as a result of lower loads due to softer diet include decreased muscle development, change in structure-function relationship of the cranium, narrowed periodontal ligament space, and changes in the mineral level of the cortical bone and alveolar jaw bone and in the glycosaminoglycans of the alveolar bone. However, the adaptive role of the dynamic bone-periodontal ligament-cementum complex to prolonged reduced loads has not been fully explained to date, especially with regard to concurrent adaptations of bone, periodontal ligament and cementum. Therefore, in the present study, using a rat model, the temporal effect of reduced functional loads on physical characteristics, such as morphology and mechanical properties and the mineral profiles of the bone-periodontal ligament-cementum complex was investigated. Two groups of 6-wk-old male Sprague-Dawley rats were fed nutritionally identical food with a stiffness range of 127-158 N/mm for hard pellet or 0.3-0.5 N/mm for soft powder forms. Spatio-temporal adaptation of the bone-periodontal ligament-cementum complex was identified by mapping changes in the following: (i) periodontal ligament collagen orientation and birefringence using polarized light microscopy, bone and cementum adaptation using histochemistry, and bone and cementum morphology using micro-X-ray computed tomography; (ii) mineral profiles of the periodontal ligament-cementum and periodontal ligament-bone interfaces by X-ray attenuation; and (iii) microhardness of bone and cementum by microindentation of specimens at ages 6, 8, 12 and 15 wk. Reduced functional loads over prolonged time resulted in the following adaptations: (i) altered periodontal ligament orientation and decreased periodontal ligament collagen birefringence, indicating decreased periodontal ligament turnover rate and decreased apical cementum resorption; (ii) a gradual increase in X-ray attenuation, owing to mineral differences, at the periodontal ligament-bone and periodontal ligament-cementum interfaces, without significant differences in the gradients for either group; (iii) significantly (p < 0.05) lower microhardness of alveolar bone (0.93 ± 0.16 GPa) and secondary cementum (0.803 ± 0.13 GPa) compared with the higher load group insert bone = (1.10 ± 0.17 and cementum = 0.940 ± 0.15 GPa, respectively) at 15 wk, indicating a temporal effect of loads on the local mineralization of bone and cementum. Based on the results from this study, the effect of reduced functional loads for a prolonged time could differentially affect morphology, mechanical properties and mineral variations of the local load-bearing sites in the bone-periodontal ligament-cementum complex. These observed local changes in turn could help to explain the overall biomechanical function and adaptations of the tooth-bone joint. From a clinical translation perspective, our study provides an insight into modulation of load on the complex for improved tooth function during periodontal disease and/or orthodontic and prosthodontic treatments. © 2011 John Wiley & Sons A/S.
Active tactile exploration using a brain-machine-brain interface.
O'Doherty, Joseph E; Lebedev, Mikhail A; Ifft, Peter J; Zhuang, Katie Z; Shokur, Solaiman; Bleuler, Hannes; Nicolelis, Miguel A L
2011-10-05
Brain-machine interfaces use neuronal activity recorded from the brain to establish direct communication with external actuators, such as prosthetic arms. It is hoped that brain-machine interfaces can be used to restore the normal sensorimotor functions of the limbs, but so far they have lacked tactile sensation. Here we report the operation of a brain-machine-brain interface (BMBI) that both controls the exploratory reaching movements of an actuator and allows signalling of artificial tactile feedback through intracortical microstimulation (ICMS) of the primary somatosensory cortex. Monkeys performed an active exploration task in which an actuator (a computer cursor or a virtual-reality arm) was moved using a BMBI that derived motor commands from neuronal ensemble activity recorded in the primary motor cortex. ICMS feedback occurred whenever the actuator touched virtual objects. Temporal patterns of ICMS encoded the artificial tactile properties of each object. Neuronal recordings and ICMS epochs were temporally multiplexed to avoid interference. Two monkeys operated this BMBI to search for and distinguish one of three visually identical objects, using the virtual-reality arm to identify the unique artificial texture associated with each. These results suggest that clinical motor neuroprostheses might benefit from the addition of ICMS feedback to generate artificial somatic perceptions associated with mechanical, robotic or even virtual prostheses.
ERIC Educational Resources Information Center
Eden, Sigal
2008-01-01
Over the years deaf and hard-of-hearing children have been reported as having difficulty with time conception and, in particular, the proper arrangement of events in a logical, temporal order. The research examined whether deaf and hard-of-hearing children perceive a temporal sequence differently under different representational modes. We compared…
Speak on time! Effects of a musical rhythmic training on children with hearing loss.
Hidalgo, Céline; Falk, Simone; Schön, Daniele
2017-08-01
This study investigates temporal adaptation in speech interaction in children with normal hearing and in children with cochlear implants (CIs) and/or hearing aids (HAs). We also address the question of whether musical rhythmic training can improve these skills in children with hearing loss (HL). Children named pictures presented on the screen in alternation with a virtual partner. Alternation rate (fast or slow) and the temporal predictability (match vs mismatch of stress occurrences) were manipulated. One group of children with normal hearing (NH) and one with HL were tested. The latter group was tested twice: once after 30 min of speech therapy and once after 30 min of musical rhythmic training. Both groups of children (NH and with HL) can adjust their speech production to the rate of alternation of the virtual partner. Moreover, while children with normal hearing benefit from the temporal regularity of stress occurrences, children with HL become sensitive to this manipulation only after rhythmic training. Rhythmic training may help children with HL to structure the temporal flow of their verbal interactions. Copyright © 2017 Elsevier B.V. All rights reserved.
Sphenoid dysplasia in neurofibromatosis type 1: a new technique for repair.
Concezio, Di Rocco; Amir, Samii; Gianpiero, Tamburrini; Luca, Massimi; Mario, Giordano
2017-06-01
Sphenoid bone dysplasia in neurofibromatosis type 1 is characterized by progressive exophthalmos and facial disfiguration secondary to herniation of meningeal and cerebral structures. We describe a technique for reconstruction of the sphenoid defect apt at preventing or correcting the ocular globe dislocation. After placement of spinal cerebrospinal fluid drainage to reduce intracranial pressure, the temporal pole is posteriorly dislocated extradurally. The greater sphenoid wing defect is identified. A titanium mesh covered by lyophilized dura, modeled in a curved fashion, is interposed between the bone defect and the cerebro-meningeal structures with its convex surface over the retracted temporal pole. The particular configuration of the titanium mesh allows a self-maintaining position due to the pressure exerted by the brain over its convex central part with its lateral margins consequently pushed and self-anchored against the medial and lateral walls of the temporal fossa. Screw fixation is not needed. The technique utilized in four cases proved to be reliable at the long-term clinical and neuroradiological controls (6 to 19 years). Sphenoid bone dysplasia in NF1, resulting in proptosis and exophthalmos, is usually progressive. It can be surgically repaired using a curved titanium mesh with the convexity faced to the temporal pole that is in the opposite fashion from all the techniques previously introduced. When utilized early in life, the technique can prevent the occurrence of the orbital and facial disfiguration.
Mackey, Allison R; Hodgetts, William E; Scott, Dylan; Small, Susan A
2016-01-01
Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull positions and contact forces for groups of infants, young children, and adults. These findings provide a better understanding of how changes in mechanical impedance might contribute to developmental changes in bone conduction hearing, and might provide insight into how fitting and output verification protocols for bone-anchored hearing systems (BAHS) could be adapted for infants and young children. Seventy-seven individuals participated in the study, including 63 infants and children (ages 1 month to 7 years) and 11 adults. Mechanical impedance magnitude for the forehead and temporal bone was collected for contact forces of 2, 4, and 5.4 N using an impedance head, a BAHS transducer, and a specially designed holding device. Mechanical impedance magnitude was determined across frequency using a stepped sine sweep from 100 to 10,000 Hz, and divided into low- and high-frequency sets for analysis. Mechanical impedance magnitude was lowest for the youngest infants and increased throughout maturation in the low frequencies. For high frequencies, the youngest infants had the highest impedance, but only for a temporal bone placement. Impedance increased with increasing contact force for low frequencies for each age group and for both skull positions. The effect of placement was significant for high frequencies for each contact force and for each age group, except for the youngest infants. Our findings show that mechanical impedance properties change systematically up to 7 years old. The significant age-related differences in mechanical impedance suggest that infant-adult differences in bone conduction thresholds may be related, at least in part, to properties of the immature skull and overlying skin and tissues. These results have important implications for fitting the soft band BAHS on infants and young children. For example, verification of output force form a BAHS on a coupler designed with adult values may not be appropriate for infants. This may also hold true for transducer calibration when assessing bone conduction hearing thresholds in infants for different skull locations. The results have two additional clinical implications for fitting soft band BAHSs. First, parents should be counseled to maintain sufficient and consistent tightness so that the output from the BAHS does not change as the child moves around during everyday activities. Second, placement of a BAHS on the forehead versus the temporal bone results in changes in mechanical impedance which may contribute to a decrease in signal level at the cochlea as it has been previously demonstrated that bone conduction thresholds are poorer at the forehead compared with a temporal placement.
A Collaborative Molecular Modeling Environment Using a Virtual Tunneling Service
Lee, Jun; Kim, Jee-In; Kang, Lin-Woo
2012-01-01
Collaborative researches of three-dimensional molecular modeling can be limited by different time zones and locations. A networked virtual environment can be utilized to overcome the problem caused by the temporal and spatial differences. However, traditional approaches did not sufficiently consider integration of different computing environments, which were characterized by types of applications, roles of users, and so on. We propose a collaborative molecular modeling environment to integrate different molecule modeling systems using a virtual tunneling service. We integrated Co-Coot, which is a collaborative crystallographic object-oriented toolkit, with VRMMS, which is a virtual reality molecular modeling system, through a collaborative tunneling system. The proposed system showed reliable quantitative and qualitative results through pilot experiments. PMID:22927721
[Petrous bone fracture. Our experience: 1999-2004].
Ramírez Sabio, J B; de Paula Vernetta, C; García Sanchís, J M; Callejo García, F J; Cortés Andrés, O; Quilis Quesada, V; Dualde Beltrán, D; Marco Algarra, J
2006-12-01
To review the petrous bone fractures during the last five years (1999-2004) in our hospital, its manage, control, and analysis onf the associated factors. To analyse the managing protocoles and current bibliography. We review 266 temporal bone fractures, 74 with petrous bone association. We analyse these fractures by sex distribution, injurie severity, otorhinolaryngological clinical findings, production mechanism and radiological findings. The cases are discussed and compared with current bibliography. Petrous bone fractures must be always suspected in patients with head trauma, specially if it associates severity and otorrhagia. It is necessary a deep colaboration between neurosurgeons, radiologists and otorhinolaryngologists to obtain a good management, control and follow up of the patients.
Reagan, Adrian C; Mallinson, Paul I; O'Connell, Timothy; McLaughlin, Patrick D; Krauss, Bernhard; Munk, Peter L; Nicolaou, Savvas; Ouellette, Hugue A
2014-01-01
Computed tomography (CT) is often used to assess the presence of occult fractures when plain radiographs are equivocal in the acute traumatic setting. While providing increased spatial resolution, conventional computed tomography is limited in the assessment of bone marrow edema, a finding that is readily detectable on magnetic resonance imaging (MRI).Dual-energy CT has recently been shown to demonstrate patterns of bone marrow edema similar to corresponding MRI studies. Dual-energy CT may therefore provide a convenient modality for further characterizing acute bony injury when MRI is not readily available. We report our initial experiences of 4 cases with imaging and clinical correlation.
Collaborative voxel-based surgical virtual environments.
Acosta, Eric; Muniz, Gilbert; Armonda, Rocco; Bowyer, Mark; Liu, Alan
2008-01-01
Virtual Reality-based surgical simulators can utilize Collaborative Virtual Environments (C-VEs) to provide team-based training. To support real-time interactions, C-VEs are typically replicated on each user's local computer and a synchronization method helps keep all local copies consistent. This approach does not work well for voxel-based C-VEs since large and frequent volumetric updates make synchronization difficult. This paper describes a method that allows multiple users to interact within a voxel-based C-VE for a craniotomy simulator being developed. Our C-VE method requires smaller update sizes and provides faster synchronization update rates than volumetric-based methods. Additionally, we address network bandwidth/latency issues to simulate networked haptic and bone drilling tool interactions with a voxel-based skull C-VE.
Reliable critical sized defect rodent model for cleft palate research.
Mostafa, Nesrine Z; Doschak, Michael R; Major, Paul W; Talwar, Reena
2014-12-01
Suitable animal models are necessary to test the efficacy of new bone grafting therapies in cleft palate surgery. Rodent models of cleft palate are available but have limitations. This study compared and modified mid-palate cleft (MPC) and alveolar cleft (AC) models to determine the most reliable and reproducible model for bone grafting studies. Published MPC model (9 × 5 × 3 mm(3)) lacked sufficient information for tested rats. Our initial studies utilizing AC model (7 × 4 × 3 mm(3)) in 8 and 16 weeks old Sprague Dawley (SD) rats revealed injury to adjacent structures. After comparing anteroposterior and transverse maxillary dimensions in 16 weeks old SD and Wistar rats, virtual planning was performed to modify MPC and AC defects dimensions, taking the adjacent structures into consideration. Modified MPC (7 × 2.5 × 1 mm(3)) and AC (5 × 2.5 × 1 mm(3)) defects were employed in 16 weeks old Wistar rats and healing was monitored by micro-computed tomography and histology. Maxillary dimensions in SD and Wistar rats were not significantly different. Preoperative virtual planning enhanced postoperative surgical outcomes. Bone healing occurred at defect margin leaving central bone void confirming the critical size nature of the modified MPC and AC defects. Presented modifications for MPC and AC models created clinically relevant and reproducible defects. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Qiu, L L; Li, S; Bai, Y X
2016-06-01
To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.
Nikolić, Slobodan; Djonić, Danijela; Zivković, Vladimir; Babić, Dragan; Juković, Fehim; Djurić, Marija
2010-09-01
The aim of our study was to determine rate of occurrence and appearance of hyperostosis frontalis interna (HFI) in females and correlation of this phenomenon with ageing. The sample included 248 deceased females: 45 of them with different types of HFI, and 203 without HFI, average age 68.3 +/- 15.4 years (range, 19-93), and 58.2 +/- 20.2 years (range, 10-101), respectively. According to our results, the rate of HFI was 18.14%. The older the woman was, the higher the possibility of HFI occurring (Pearson correlation 0.211, N=248, P=0.001), but the type of HFI did not correlate with age (Pearson correlation 0.229, N=45, P=0.131). Frontal and temporal bone were significantly thicker in women with than in women without HFI (t= -10.490, DF=246, P=0.000, and t= -5.658, DF=246, P=0.000, respectively). These bones became thicker with ageing (Pearson correlation 0.178, N=248, P=0.005, and 0.303, N=248, P=0.000, respectively). The best predictors of HFI occurrence were respectively, frontal bone thickness, temporal bone thickness, and age(Wald. coeff.=35.487, P=0.000; Wald. coeff.=3.288, P=0.070, and Wald.coeff. =2.727, P =0.099). Diagnosis of HFI depends not only on frontal bone thickness, but also on waviness of internal plate of the frontal bone, as well as-the involvement of the inner bone surface.
Koutouzis, Theofilos; Lipton, David
2016-01-01
The aim of this study was to evaluate the necessity for additional regenerative procedures following healing of compromised and noncompromised extraction sockets with alveolar ridge preservation procedures through the use of virtual implant imaging software. The cohort was comprised of 87 consecutive patients subjected to a single maxillary tooth extraction with an alveolar ridge preservation procedure for subsequent implant placement. Patients were divided into two main groups based on the integrity of the buccal bone plate following teeth extraction. Patients in the compromised socket (CS) group (n = 52) had partial or complete buccal bone plate loss, and patients in the noncompromised socket (NCS) group (n = 35) exhibited no bone loss of their socket walls following tooth extraction. Following 4 to 6 months of healing, all patients had a cone beam computed tomography (CBCT) study. Root-formed implants were placed virtually in an ideal prosthetic position. The number of implants per group and location (anterior, premolar, molar) exhibiting exposed buccal implant surface was calculated. In the CS group, 5 out of 19 anterior implants (26.3%), 4 out of 14 premolar implants (28.5%), and 7 out of 19 molar implants (36.8%) had exposed buccal surfaces. In the NCS group, 4 out of 9 anterior implants (44.4%), 2 out of 9 premolar implants (22.2%), and 4 out of 17 molar implants (23.5%) had exposed buccal surfaces. There were no statistically significant differences for intragroup and intergroup comparisons (χ² test, P > .05). This study failed to find statistically significant differences in the frequency of implants with exposed buccal surfaces placed virtually, following treatment of compromised and noncompromised sockets. A high proportion (22% to 44%) of sites had implants that potentially needed additional regenerative procedures.
Mucous retention cyst of temporal bone: a mimic of cholesteatoma on DW-MRI.
Karandikar, Amit; Goh, Julian; Loke, Siu Cheng; Yeo, Seng Beng; Tan, Tiong Yong
2013-01-01
Non-EPI DW imaging is increasingly being used as a sensitive sequence in detecting cholesteatomas especially if CT findings are not confirmatory. Cholesteatoma appears as a hyperintense focus on DWI. We present two cases of mucous retention cysts in the mastoid temporal bone/middle ear cavity, which present as hyperintense on non-EPI DWI and potentially may mimic cholesteatomas. Differentiating between the two conditions is important, as surgery can be avoided in mucous retention cysts. We have also discussed ways to differentiate between these two conditions on MRI. To our knowledge, this entity is not reported previously. © 2013 Elsevier Inc. All rights reserved.
[Surgical treatment of patients with exudative otitis media].
Dmitriev, N S; Mileshina, N A
2003-01-01
The article concerns peculiarities of surgery for chronic exudative otitis media (CEOM). The significance of miringotomy, tympanostomy, tympanotomy and tympanoantrotomy is demonstrated. The experience of the authors in surgical treatment and postoperative management of CEOM is reviewed. Of primary importance is valid selection of patients for each operation and choice of ventilatory tubes depending on the disease stage. Incidence rate and causes of recurrences in respect to the patients' age are presented and the role of follow-up in prevention of CEOM recurrences is shown. Use of temporal bone computed tomography in CEOM is specified. Key words: exudative otitis media, tympanostomy, ventilation tubes, CT of the temporal bone.
Lateral semicircular canal osteoma presenting as chronic postaural fistula.
Gill, Charn; Muzaffar, Jameel; Kumar, Raghu Sampath; Irving, Richard
2018-05-12
Temporal bone osteoma is an unusual pathology which can occur by birth or can be acquired and mostly involves the tympanomastoid segment of the temporal bone. Osteomas arising from the otic capsule are extremely rare, and there has been only one other report of a lateral semicircular canal osteoma in the literature. We report a similar case of an acquired lateral canal osteoma which presented as a chronic postaural fistula in an ear previously operated for paediatric cholesteatoma. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Gustatory otalgia and wet ear syndrome: a possible cross-innervation after ear surgery.
Saito, H
1999-04-01
The chorda tympani and Arnold's nerves have close approximation to each other and their cross-innervation is possible after ear surgery. A retrospective study was performed with a temporal bone pathology case and two clinical cases as representatives of such a possibility. Patients had severe otalgia and wet ear during gustatory stimulation. A temporal bone pathology case was studied under a light microscope. Earache and/or wet ear were provoked during gustatory stimulation. Wet ear was tested with iodine-starch reaction after the subject tasted lemon juice. The temporal bone specimen has clusters of regenerated fibers in the tympanic cavity in the area of the chorda tympani and Arnold's nerves, suggesting a possibility of mixing. There are regenerated fibers in the iter chordae anterius, showing successful bridging of the chorda tympani nerves across a long gap. Detachment of the skin over the operated mastoid bowl obscured signs in one clinical case. Another clinical case of gustatory wet ear showed objective evidence of cross-innervation with iodine-starch reaction. The detachment procedure and iodine-starch reaction were the proofs that the signs were related to regenerated fibers. This is the first report of gustatory otalgia and wet ear after ear surgery.
Planning nonlinear access paths for temporal bone surgery.
Fauser, Johannes; Sakas, Georgios; Mukhopadhyay, Anirban
2018-05-01
Interventions at the otobasis operate in the narrow region of the temporal bone where several highly sensitive organs define obstacles with minimal clearance for surgical instruments. Nonlinear trajectories for potential minimally invasive interventions can provide larger distances to risk structures and optimized orientations of surgical instruments, thus improving clinical outcomes when compared to existing linear approaches. In this paper, we present fast and accurate planning methods for such nonlinear access paths. We define a specific motion planning problem in [Formula: see text] with notable constraints in computation time and goal pose that reflect the requirements of temporal bone surgery. We then present [Formula: see text]-RRT-Connect: two suitable motion planners based on bidirectional Rapidly exploring Random Tree (RRT) to solve this problem efficiently. The benefits of [Formula: see text]-RRT-Connect are demonstrated on real CT data of patients. Their general performance is shown on a large set of realistic synthetic anatomies. We also show that these new algorithms outperform state-of-the-art methods based on circular arcs or Bézier-Splines when applied to this specific problem. With this work, we demonstrate that preoperative and intra-operative planning of nonlinear access paths is possible for minimally invasive surgeries at the otobasis.
Creating an Optimal 3D Printed Model for Temporal Bone Dissection Training.
Takahashi, Kuniyuki; Morita, Yuka; Ohshima, Shinsuke; Izumi, Shuji; Kubota, Yamato; Yamamoto, Yutaka; Takahashi, Sugata; Horii, Arata
2017-07-01
Making a 3-dimensional (3D) temporal bone model is simple using a plaster powder bed and an inkjet printer. However, it is difficult to reproduce air-containing spaces and precise middle ear structures. The objective of this study was to overcome these problems and create a temporal bone model that would be useful both as a training tool and for preoperative simulation. Drainage holes were made to remove excess materials from air-containing spaces, ossicle ligaments were manually changed to bony structures, and small and/or soft tissue structures were colored differently while designing the 3D models. The outcomes were evaluated by 3 procedures: macroscopic and endoscopic inspection of the model, comparison of computed tomography (CT) images of the model to the original CT, and assessment of tactile sensation and reproducibility by 20 surgeons performing surgery on the model. Macroscopic and endoscopic inspection, CT images, and assessment by surgeons were in agreement in terms of reproducibility of model structures. Most structures could be reproduced, but the stapes, tympanic sinus, and mastoid air cells were unsatisfactory. Perioperative tactile sensation of the model was excellent. Although this model still does not embody perfect reproducibility, it proved sufficiently practical for use in surgical training.
Safety of MRI with metallic middle ear implants.
Tohme, Souheil M; Karkas, Alexandre A; Romanos, Bassam H
2003-01-01
Investigation of the effects of magnetic resonance fields on commonly used metallic middle ear implants. Nine middle ear prostheses (seven containing stainless steel and two made of pure gold used as control) were tested in vitro and one stainless steel stapedectomy prosthesis was tested on a cadaveric temporal bone. Each metallic prosthesis was placed in an empty Petri dish and introduced into a 1.5-tesla (T) magnetic resonance imaging (MRI) unit. Most of the prostheses were then placed in a water-filled Petri dish and reintroduced into the MRI unit. Eventual in vitro displacement was assessed visually by two means. In situ testing was done by implanting a piston in a cadaveric temporal bone and performing MR sequences ; any possible displacement was then assessed by CT scan and under microscopic vision. None of the prostheses was displaced in the empty Petri dish. However, while in the water-filled Petri dish, three of these moved with the flux. The implanted piston in the temporal bone did not move. The displacement of three of the prostheses in water is not relevant in real clinical situations. MRI can thus be considered safe in usual clinical settings, as far as our studied implants are concerned.
Cholesteatomas of the temporal bone: role of computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, D.W.; Voorhees, R.L.; Lufkin, R.B.
1983-09-01
Computed tomography (CT) of the temporal bone was performed in 64 patients thought to have a cholesteatoma of the middle ear. Twenty had not had surgery before, while 44 had been operated on; special consideration was given to 21 patients who were scanned immediately before a second operation and had confirmation of the CT findings. Inflammatory disease without cholesteatoma was characterized by absence of erosion of the otic capsule or ossicular chain. Sharply circumscribed cholesteatomas were easily diagnosed by CT. When they were combined with scarring, granulation tissue, or postsurgical changes, the resulting soft-tissue masses were indistinguishable, although cholesteatoma maymore » be suspected if there is evidence of progressive bone erosion about the middle ear. CT can play a major role in postoperative follow-up by confirming that the ear is normal and demonstrating displacement of ossicular grafts or prostheses.« less
NASA Astrophysics Data System (ADS)
DeVries, B.; Huang, W.; Huang, C.; Jones, J. W.; Lang, M. W.; Creed, I. F.; Carroll, M.
2017-12-01
The function of wetlandscapes in hydrological and biogeochemical cycles is largely governed by surface inundation, with small wetlands that experience periodic inundation playing a disproportionately large role in these processes. However, the spatial distribution and temporal dynamics of inundation in these wetland systems are still poorly understood, resulting in large uncertainties in global water, carbon and greenhouse gas budgets. Satellite imagery provides synoptic and repeat views of the Earth's surface and presents opportunities to fill this knowledge gap. Despite the proliferation of Earth Observation satellite missions in the past decade, no single satellite sensor can simultaneously provide the spatial and temporal detail needed to adequately characterize inundation in small, dynamic wetland systems. Surface water data products must therefore integrate observations from multiple satellite sensors in order to address this objective, requiring the development of improved and coordinated algorithms to generate consistent estimates of surface inundation. We present a suite of algorithms designed to detect surface inundation in wetlands using data from a virtual constellation of optical and radar sensors comprising the Landsat and Sentinel missions (DeVries et al., 2017). Both optical and radar algorithms were able to detect inundation in wetlands without the need for external training data, allowing for high-efficiency monitoring of wetland inundation at large spatial and temporal scales. Applying these algorithms across a gradient of wetlands in North America, preliminary findings suggest that while these fully automated algorithms can detect wetland inundation at higher spatial and temporal resolutions than currently available surface water data products, limitations specific to the satellite sensors and their acquisition strategies are responsible for uncertainties in inundation estimates. Further research is needed to investigate strategies for integrating optical and radar data from virtual constellations, with a focus on reducing uncertainties, maximizing spatial and temporal detail, and establishing consistent records of wetland inundation over time. The findings and conclusions in this article do not necessarily represent the views of the U.S. Government.
A Multi-Stage Method for Connecting Participatory Sensing and Noise Simulations
Hu, Mingyuan; Che, Weitao; Zhang, Qiuju; Luo, Qingli; Lin, Hui
2015-01-01
Most simulation-based noise maps are important for official noise assessment but lack local noise characteristics. The main reasons for this lack of information are that official noise simulations only provide information about expected noise levels, which is limited by the use of large-scale monitoring of noise sources, and are updated infrequently. With the emergence of smart cities and ubiquitous sensing, the possible improvements enabled by sensing technologies provide the possibility to resolve this problem. This study proposed an integrated methodology to propel participatory sensing from its current random and distributed sampling origins to professional noise simulation. The aims of this study were to effectively organize the participatory noise data, to dynamically refine the granularity of the noise features on road segments (e.g., different portions of a road segment), and then to provide a reasonable spatio-temporal data foundation to support noise simulations, which can be of help to researchers in understanding how participatory sensing can play a role in smart cities. This study first discusses the potential limitations of the current participatory sensing and simulation-based official noise maps. Next, we explain how participatory noise data can contribute to a simulation-based noise map by providing (1) spatial matching of the participatory noise data to the virtual partitions at a more microscopic level of road networks; (2) multi-temporal scale noise estimations at the spatial level of virtual partitions; and (3) dynamic aggregation of virtual partitions by comparing the noise values at the relevant temporal scale to form a dynamic segmentation of each road segment to support multiple spatio-temporal noise simulations. In this case study, we demonstrate how this method could play a significant role in a simulation-based noise map. Together, these results demonstrate the potential benefits of participatory noise data as dynamic input sources for noise simulations on multiple spatio-temporal scales. PMID:25621604
A multi-stage method for connecting participatory sensing and noise simulations.
Hu, Mingyuan; Che, Weitao; Zhang, Qiuju; Luo, Qingli; Lin, Hui
2015-01-22
Most simulation-based noise maps are important for official noise assessment but lack local noise characteristics. The main reasons for this lack of information are that official noise simulations only provide information about expected noise levels, which is limited by the use of large-scale monitoring of noise sources, and are updated infrequently. With the emergence of smart cities and ubiquitous sensing, the possible improvements enabled by sensing technologies provide the possibility to resolve this problem. This study proposed an integrated methodology to propel participatory sensing from its current random and distributed sampling origins to professional noise simulation. The aims of this study were to effectively organize the participatory noise data, to dynamically refine the granularity of the noise features on road segments (e.g., different portions of a road segment), and then to provide a reasonable spatio-temporal data foundation to support noise simulations, which can be of help to researchers in understanding how participatory sensing can play a role in smart cities. This study first discusses the potential limitations of the current participatory sensing and simulation-based official noise maps. Next, we explain how participatory noise data can contribute to a simulation-based noise map by providing (1) spatial matching of the participatory noise data to the virtual partitions at a more microscopic level of road networks; (2) multi-temporal scale noise estimations at the spatial level of virtual partitions; and (3) dynamic aggregation of virtual partitions by comparing the noise values at the relevant temporal scale to form a dynamic segmentation of each road segment to support multiple spatio-temporal noise simulations. In this case study, we demonstrate how this method could play a significant role in a simulation-based noise map. Together, these results demonstrate the potential benefits of participatory noise data as dynamic input sources for noise simulations on multiple spatio-temporal scales.
Balachandran, Ramya; Labadie, Robert F.
2015-01-01
Purpose A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. Methods An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. Results The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of 45° and higher as well as longer cantilevered drill lengths. Conclusion The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure. PMID:26183149
Dillon, Neal P; Balachandran, Ramya; Labadie, Robert F
2016-03-01
A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of [Formula: see text] and higher as well as longer cantilevered drill lengths. The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure.
Nauer, Claude Bertrand; Zubler, Christoph; Weisstanner, Christian; Stieger, Christof; Senn, Pascal; Arnold, Andreas
2012-03-01
The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols.
A three-dimensional analysis of the endolymph drainage system in Ménière disease.
Monsanto, Rafael da Costa; Pauna, Henrique F; Kwon, Geeyoun; Schachern, Patricia A; Tsuprun, Vladimir; Paparella, Michael M; Cureoglu, Sebahattin
2017-05-01
To measure the volume of the endolymph drainage system in temporal bone specimens with Ménière disease, as compared with specimens with endolymphatic hydrops without vestibular symptoms and with nondiseased specimens STUDY DESIGN: Comparative human temporal bone analysis. We generated three-dimensional models of the vestibular aqueduct, endolymphatic sinus and duct, and intratemporal portion of the endolymphatic sac and calculated the volume of those structures. We also measured the internal and external aperture of the vestibular aqueduct, as well as the opening (if present) of the utriculoendolymphatic (Bast's) valve and compared the measurements in our three study groups. The volume of the vestibular aqueduct and of the endolymphatic sinus, duct, and intratemporal endolymphatic sac was significantly lower in the Ménière disease group than in the endolymphatic hydrops group (P <.05). The external aperture of the vestibular aqueduct was also smaller in the Ménière disease group. Bast's valve was open only in some specimens in the Ménière disease group. In temporal bones with Ménière disease, the volume of the vestibular aqueduct, endolymphatic duct, and intratemporal endolymphatic sac was lower, and the external aperture of the vestibular aqueduct was smaller as compared with bones from donors who had endolymphatic hydrops without vestibular symptoms and with nondiseased bones. The open status of the Bast's valve in the Ménière disease group could be secondary to higher retrograde endolymph pressures caused by smaller drainage systems. These anatomic findings could correlate with the reason that some patients with hydrops develop clinical symptoms, whereas others do not. N/A Laryngoscope, 127:E170-E175, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Comparison of Bone Grafts From Various Donor Sites in Human Bone Specimens.
Kamal, Mohammad; Gremse, Felix; Rosenhain, Stefanie; Bartella, Alexander K; Hölzle, Frank; Kessler, Peter; Lethaus, Bernd
2018-05-14
The objective of the current study was to compare the three-dimensional (3D) morphometric microstructure in human cadaveric bone specimens taken from various commonly utilized donor sites for autogenous bone grafting. Autogenous bone grafts can be harvested from various anatomic sites and express heterogeneous bone quality with a specific 3D microstructure for each site. The long-term structural integrity and susceptibility to resorption of the graft depend on the selected donor bone. Micro-computed tomography generates high-resolution datasets of bone structures and calcifications making this modality versatile for microarchitecture analysis and quantification of the bone. Six bone specimens, 10 mm in length, where anatomically possible, were obtained from various anatomical sites from 10 human dentate cadavers (4 men, 6 women, mean age 69.5 years). Specimens were scanned using a micro-computed tomography device and volumetrically reconstructed. A virtual cylindrical inclusion was reconstructed to analyze the bone mineral density and structural morphometric analysis using bone indices: relative bone volume, surface density, trabecular thicknesses, and trabecular separation. Calvarial bone specimens showed the highest mineral density, followed by the chin, then mandibular ramus then the tibia, whereas iliac crest and maxillary tuberosity had lower bone mineral densities. The pairwise comparison revealed statistically significant differences in the bone mineral density and relative bone volume index in the calvaria, mandibular ramus, mandibular symphysis groups when compared with those in the iliac crest and maxillary tuberosity, suggesting higher bone quality in the former groups than in the latter; tibial specimens expressed variable results.
Buck, Ursula; Naether, Silvio; Braun, Marcel; Thali, Michael
2008-09-18
Non-invasive documentation methods such as surface scanning and radiological imaging are gaining in importance in the forensic field. These three-dimensional technologies provide digital 3D data, which are processed and handled in the computer. However, the sense of touch gets lost using the virtual approach. The haptic device enables the use of the sense of touch to handle and feel digital 3D data. The multifunctional application of a haptic device for forensic approaches is evaluated and illustrated in three different cases: the representation of bone fractures of the lower extremities, by traffic accidents, in a non-invasive manner; the comparison of bone injuries with the presumed injury-inflicting instrument; and in a gunshot case, the identification of the gun by the muzzle imprint, and the reconstruction of the holding position of the gun. The 3D models of the bones are generated from the Computed Tomography (CT) images. The 3D models of the exterior injuries, the injury-inflicting tools and the bone injuries, where a higher resolution is necessary, are created by the optical surface scan. The haptic device is used in combination with the software FreeForm Modelling Plus for touching the surface of the 3D models to feel the minute injuries and the surface of tools, to reposition displaced bone parts and to compare an injury-causing instrument with an injury. The repositioning of 3D models in a reconstruction is easier, faster and more precisely executed by means of using the sense of touch and with the user-friendly movement in the 3D space. For representation purposes, the fracture lines of bones are coloured. This work demonstrates that the haptic device is a suitable and efficient application in forensic science. The haptic device offers a new way in the handling of digital data in the virtual 3D space.
Gunz, Philipp; Ramsier, Marissa; Kuhrig, Melanie; Hublin, Jean-Jacques; Spoor, Fred
2012-01-01
The bony labyrinth in the temporal bone houses the sensory systems of balance and hearing. While the overall structure of the semicircular canals and cochlea is similar across therian mammals, their detailed morphology varies even among closely related groups. As such, the shape of the labyrinth carries valuable functional and phylogenetic information. Here we introduce a new, semilandmark-based three-dimensional geometric morphometric approach to shape analysis of the labyrinth, as a major improvement upon previous metric studies based on linear measurements and angles. We first provide a detailed, step-by-step description of the measurement protocol. Subsequently, we test our approach using a geographically diverse sample of 50 recent modern humans and 30 chimpanzee specimens belonging to Pan troglodytes troglodytes and P. t. verus. Our measurement protocol can be applied to CT scans of different spatial resolutions because it primarily quantifies the midline skeleton of the bony labyrinth. Accurately locating the lumen centre of the semicircular canals and the cochlea is not affected by the partial volume and thresholding effects that can make the comparison of the outer border problematic. After virtually extracting the bony labyrinth from CT scans of the temporal bone, we computed its midline skeleton by thinning the encased volume. On the resulting medial axes of the semicircular canals and cochlea we placed a sequence of semilandmarks. After Procrustes superimposition, the shape coordinates were analysed using multivariate statistics. We found statistically significant shape differences between humans and chimpanzees which corroborate previous analyses of the labyrinth based on traditional measurements. As the geometric relationship among the semilandmark coordinates was preserved throughout the analysis, we were able to quantify and visualize even small-scale shape differences. Notably, our approach made it possible to detect and visualize subtle, yet statistically significant (P = 0.009), differences between two chimpanzee subspecies in the shape of their semicircular canals. The ability to discriminate labyrinth shape at the subspecies level demonstrates that the approach presented here has great potential in future taxonomic studies of fossil specimens. PMID:22404255
Adhesive bone bonding prospects for lithium disilicate ceramic implants
NASA Astrophysics Data System (ADS)
Vennila Thirugnanam, Sakthi Kumar
Temporomandibular Joint (TMJ) implants articulating mandible with temporal bone in humans have a very high failure rate. Metallic TMJ implants available in the medical market are not osseointegrated, but bond only by mechanical interlocking using screws which may fail, mandating a second surgery for removal. Stress concentration around fixture screws leads to aseptic loosening or fracture of the bone. It has been proposed that this problem can be overcome by using an all-ceramic TMJ implant bonded to bone with dental adhesives. Structural ceramics are promising materials with an excellent track record in the field of dentis.
Tetsworth, Kevin; Block, Steve; Glatt, Vaida
2017-01-01
3D printing technology has revolutionized and gradually transformed manufacturing across a broad spectrum of industries, including healthcare. Nowhere is this more apparent than in orthopaedics with many surgeons already incorporating aspects of 3D modelling and virtual procedures into their routine clinical practice. As a more extreme application, patient-specific 3D printed titanium truss cages represent a novel approach for managing the challenge of segmental bone defects. This review illustrates the potential indications of this innovative technique using 3D printed titanium truss cages in conjunction with the Masquelet technique. These implants are custom designed during a virtual surgical planning session with the combined input of an orthopaedic surgeon, an orthopaedic engineering professional and a biomedical design engineer. The ability to 3D model an identical replica of the original intact bone in a virtual procedure is of vital importance when attempting to precisely reconstruct normal anatomy during the actual procedure. Additionally, other important factors must be considered during the planning procedure, such as the three-dimensional configuration of the implant. Meticulous design is necessary to allow for successful implantation through the planned surgical exposure, while being aware of the constraints imposed by local anatomy and prior implants. This review will attempt to synthesize the current state of the art as well as discuss our personal experience using this promising technique. It will address implant design considerations including the mechanical, anatomical and functional aspects unique to each case. PMID:28220752
Tetsworth, Kevin; Block, Steve; Glatt, Vaida
2017-01-01
3D printing technology has revolutionized and gradually transformed manufacturing across a broad spectrum of industries, including healthcare. Nowhere is this more apparent than in orthopaedics with many surgeons already incorporating aspects of 3D modelling and virtual procedures into their routine clinical practice. As a more extreme application, patient-specific 3D printed titanium truss cages represent a novel approach for managing the challenge of segmental bone defects. This review illustrates the potential indications of this innovative technique using 3D printed titanium truss cages in conjunction with the Masquelet technique. These implants are custom designed during a virtual surgical planning session with the combined input of an orthopaedic surgeon, an orthopaedic engineering professional and a biomedical design engineer. The ability to 3D model an identical replica of the original intact bone in a virtual procedure is of vital importance when attempting to precisely reconstruct normal anatomy during the actual procedure. Additionally, other important factors must be considered during the planning procedure, such as the three-dimensional configuration of the implant. Meticulous design is necessary to allow for successful implantation through the planned surgical exposure, while being aware of the constraints imposed by local anatomy and prior implants. This review will attempt to synthesize the current state of the art as well as discuss our personal experience using this promising technique. It will address implant design considerations including the mechanical, anatomical and functional aspects unique to each case. © The Authors, published by EDP Sciences, 2017.
Sakamoto, Ryo; Yakami, Masahiro; Fujimoto, Koji; Nakagomi, Keita; Kubo, Takeshi; Emoto, Yutaka; Akasaka, Thai; Aoyama, Gakuto; Yamamoto, Hiroyuki; Miller, Michael I; Mori, Susumu; Togashi, Kaori
2017-11-01
Purpose To determine the improvement of radiologist efficiency and performance in the detection of bone metastases at serial follow-up computed tomography (CT) by using a temporal subtraction (TS) technique based on an advanced nonrigid image registration algorithm. Materials and Methods This retrospective study was approved by the institutional review board, and informed consent was waived. CT image pairs (previous and current scans of the torso) in 60 patients with cancer (primary lesion location: prostate, n = 14; breast, n = 16; lung, n = 20; liver, n = 10) were included. These consisted of 30 positive cases with a total of 65 bone metastases depicted only on current images and confirmed by two radiologists who had access to additional imaging examinations and clinical courses and 30 matched negative control cases (no bone metastases). Previous CT images were semiautomatically registered to current CT images by the algorithm, and TS images were created. Seven radiologists independently interpreted CT image pairs to identify newly developed bone metastases without and with TS images with an interval of at least 30 days. Jackknife free-response receiver operating characteristics (JAFROC) analysis was conducted to assess observer performance. Reading time was recorded, and usefulness was evaluated with subjective scores of 1-5, with 5 being extremely useful and 1 being useless. Significance of these values was tested with the Wilcoxon signed-rank test. Results The subtraction images depicted various types of bone metastases (osteolytic, n = 28; osteoblastic, n = 26; mixed osteolytic and blastic, n = 11) as temporal changes. The average reading time was significantly reduced (384.3 vs 286.8 seconds; Wilcoxon signed rank test, P = .028). The average figure-of-merit value increased from 0.758 to 0.835; however, this difference was not significant (JAFROC analysis, P = .092). The subjective usefulness survey response showed a median score of 5 for use of the technique (range, 3-5). Conclusion TS images obtained from serial CT scans using nonrigid registration successfully depicted newly developed bone metastases and showed promise for their efficient detection. © RSNA, 2017 Online supplemental material is available for this article.
Retention of Mastoidectomy Skills After Virtual Reality Simulation Training.
Andersen, Steven Arild Wuyts; Konge, Lars; Cayé-Thomasen, Per; Sørensen, Mads Sølvsten
2016-07-01
The ultimate goal of surgical training is consolidated skills with a consistently high performance. However, surgical skills are heterogeneously retained and depend on a variety of factors, including the task, cognitive demands, and organization of practice. Virtual reality (VR) simulation is increasingly being used in surgical skills training, including temporal bone surgery, but there is a gap in knowledge on the retention of mastoidectomy skills after VR simulation training. To determine the retention of mastoidectomy skills after VR simulation training with distributed and massed practice and to investigate participants' cognitive load during retention procedures. A prospective 3-month follow-up study of a VR simulation trial was conducted from February 6 to September 19, 2014, at an academic teaching hospital among 36 medical students: 19 from a cohort trained with distributed practice and 17 from a cohort trained with massed practice. Participants performed 2 virtual mastoidectomies in a VR simulator a mean of 3.2 months (range, 2.4-5.0 months) after completing initial training with 12 repeated procedures. Practice blocks were spaced apart in time (distributed), or all procedures were performed in 1 day (massed). Performance of the virtual mastoidectomy as assessed by 2 masked senior otologists using a modified Welling scale, as well as cognitive load as estimated by reaction time to perform a secondary task. Among 36 participants, mastoidectomy final-product skills were largely retained at 3 months (mean change in score, 0.1 points; P = .89) regardless of practice schedule, but the group trained with massed practice took more time to complete the task. The performance of the massed practice group increased significantly from the first to the second retention procedure (mean change, 1.8 points; P = .001), reflecting that skills were less consolidated. For both groups, increases in reaction times in the secondary task (distributed practice group: mean pretraining relative reaction time, 1.42 [95% CI, 1.37-1.47]; mean end of training relative reaction time, 1.24 [95% CI, 1.16-1.32]; and mean retention relative reaction time, 1.36 [95% CI, 1.30-1.42]; massed practice group: mean pretraining relative reaction time, 1.34 [95% CI, 1.28-1.40]; mean end of training relative reaction time, 1.31 [95% CI, 1.21-1.42]; and mean retention relative reaction time, 1.39 [95% CI, 1.31-1.46]) indicated that cognitive load during the virtual procedures had returned to the pretraining level. Mastoidectomy skills acquired under time-distributed practice conditions were retained better than skills acquired under massed practice conditions. Complex psychomotor skills should be regularly reinforced to consolidate both motor and cognitive aspects. Virtual reality simulation training provides the opportunity for such repeated training and should be integrated into training curricula.
Villa, C; Olsen, K B; Hansen, S H
2017-09-01
Post-mortem CT scanning (PMCT) has been introduced at several forensic medical institutions many years ago and has proved to be a useful tool. 3D models of bones, skin, internal organs and bullet paths can rapidly be generated using post-processing software. These 3D models reflect the individual physiognomics and can be used to create whole-body 3D virtual animations. In such way, virtual reconstructions of the probable ante-mortem postures of victims can be constructed and contribute to understand the sequence of events. This procedure is demonstrated in two victims of gunshot injuries. Case #1 was a man showing three perforating gunshot wounds, who died due to the injuries of the incident. Whole-body PMCT was performed and 3D reconstructions of bones, relevant internal organs and bullet paths were generated. Using 3ds Max software and a human anatomy 3D model, a virtual animated body was built and probable ante-mortem postures visualized. Case #2 was a man presenting three perforating gunshot wounds, who survived the incident: one in the left arm and two in the thorax. Only CT scans of the thorax, abdomen and the injured arm were provided by the hospital. Therefore, a whole-body 3D model reflecting the anatomical proportions of the patient was made combining the actual bones of the victim with those obtained from the human anatomy 3D model. The resulted 3D model was used for the animation process. Several probable postures were also visualized in this case. It has be shown that in Case #1 the lesions and the bullet path were not consistent with an upright standing position; instead, the victim was slightly bent forward, i.e. he was sitting or running when he was shot. In Case #2, one of the bullets could have passed through the arm and continued into the thorax. In conclusion, specialized 3D modelling and animation techniques allow for the reconstruction of ante-mortem postures based on both PMCT and clinical CT. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Vasilić, B.; Ladinsky, G. A.; Saha, P. K.; Wehrli, F. W.
2006-03-01
Osteoporosis is the cause of over 1.5 million bone fractures annually. Most of these fractures occur in sites rich in trabecular bone, a complex network of bony struts and plates found throughout the skeleton. The three-dimensional structure of the trabecular bone network significantly determines mechanical strength and thus fracture resistance. Here we present a data acquisition and processing system that allows efficient noninvasive assessment of trabecular bone structure through a "virtual bone biopsy". High-resolution MR images are acquired from which the trabecular bone network is extracted by estimating the partial bone occupancy of each voxel. A heuristic voxel subdivision increases the effective resolution of the bone volume fraction map and serves a basis for subsequent analysis of topological and orientational parameters. Semi-automated registration and segmentation ensure selection of the same anatomical location in subjects imaged at different time points during treatment. It is shown with excerpts from an ongoing clinical study of early post-menopausal women, that significant reduction in network connectivity occurs in the control group while the structural integrity is maintained in the hormone replacement group. The system described should be suited for large-scale studies designed to evaluate the efficacy of therapeutic intervention in subjects with metabolic bone disease.
Towards monitoring the englacial fracture state using virtual-reflector seismology
NASA Astrophysics Data System (ADS)
Lindner, F.; Weemstra, C.; Walter, F.; Hadziioannou, C.
2018-04-01
In seismology, coda wave interferometry (CWI) is an effective tool to monitor time-lapse changes using later arriving, multiply scattered coda waves. Typically, CWI relies on an estimate of the medium's impulse response. The latter is retrieved through simple time-averaging of receiver-receiver cross-correlations of the ambient field, i.e. seismic interferometry (SI). In general, the coda are induced by heterogeneities in the Earth. Being comparatively homogeneous, however, ice bodies such as glaciers and ice sheets exhibit little scattering. In addition, the temporal stability of the time-averaged cross-correlations suffers from temporal variations in the distribution and amplitude of the passive seismic sources. Consequently, application of CWI to ice bodies is currently limited. Nevertheless, fracturing and changes in the englacial macroscopic water content alter the bulk elastic properties of ice bodies, which can be monitored with cryoseismological measurements. To overcome the current limited applicability of CWI to ice bodies, we therefore introduce virtual-reflector seismology (VRS). VRS relies on a so-called multidimensional deconvolution (MDD) process of the time-averaged crosscorrelations. The technique results in the retrieval of a medium response that includes virtual reflections from a contour of receivers enclosing the region of interest (i.e., the region to be monitored). The virtual reflections can be interpreted as artificial coda replacing the (lacking) natural scattered coda. Hence, this artificial coda might be exploited for the purpose of CWI. From an implementation point of view, VRS is similar to SI by MDD, which, as its name suggests, also relies on a multidimensional deconvolution process. SI by MDD, however, does not generate additional virtual reflections. Advantageously, both techniques mitigate spurious coda changes associated with temporal variations in the distribution and amplitude of the passive seismic sources. In this work, we apply SI by MDD and VRS to synthetic and active seismic surface-wave data. The active seismic data were acquired on Glacier de la Plaine Morte, Switzerland. We successfully retrieve virtual reflections through the application of VRS to this active seismic data. In application to both synthetic and active seismic data, we show the potential of VRS to monitor time-lapse changes. In addition, we find that SI by MDD allows for a more accurate determination of phase velocity.
The dynamics of adult haematopoiesis in the bone and bone marrow environment.
Ho, Miriel S H; Medcalf, Robert L; Livesey, Stephen A; Traianedes, Kathy
2015-08-01
This review explores the dynamic relationship between bone and bone marrow in the genesis and regulation of adult haematopoiesis and will provide an overview of the haematopoietic hierarchical system. This will include the haematopoietic stem cell (HSC) and its niches, as well as discuss emerging evidence of the reciprocal interplay between bone and bone marrow, and support of the pleiotropic role played by bone cells in the regulation of HSC proliferation, differentiation and function. In addition, this review will present demineralized bone matrix as a unique acellular matrix platform that permits the generation of ectopic de novo bone and bone marrow and provides a means of investigating the temporal sequence of bone and bone marrow regeneration. It is anticipated that the utilization of this matrix-based approach will help researchers in gaining deeper insights into the major events leading to adult haematopoiesis in the bone marrow. Furthermore, this model may potentially offer new avenues to manipulate the HSC niche and hence influence the functional output of the haematopoietic system. © 2015 John Wiley & Sons Ltd.
Using virtual robot-mediated play activities to assess cognitive skills.
Encarnação, Pedro; Alvarez, Liliana; Rios, Adriana; Maya, Catarina; Adams, Kim; Cook, Al
2014-05-01
To evaluate the feasibility of using virtual robot-mediated play activities to assess cognitive skills. Children with and without disabilities utilized both a physical robot and a matching virtual robot to perform the same play activities. The activities were designed such that successfully performing them is an indication of understanding of the underlying cognitive skills. Participants' performance with both robots was similar when evaluated by the success rates in each of the activities. Session video analysis encompassing participants' behavioral, interaction and communication aspects revealed differences in sustained attention, visuospatial and temporal perception, and self-regulation, favoring the virtual robot. The study shows that virtual robots are a viable alternative to the use of physical robots for assessing children's cognitive skills, with the potential of overcoming limitations of physical robots such as cost, reliability and the need for on-site technical support. Virtual robots can provide a vehicle for children to demonstrate cognitive understanding. Virtual and physical robots can be used as augmentative manipulation tools allowing children with disabilities to actively participate in play, educational and therapeutic activities. Virtual robots have the potential of overcoming limitations of physical robots such as cost, reliability and the need for on-site technical support.
Occupational Noise Exposure and Risk for Noise-Induced Hearing Loss Due to Temporal Bone Drilling.
Vaisbuch, Yona; Alyono, Jennifer C; Kandathil, Cherian; Wu, Stanley H; Fitzgerald, Matthew B; Jackler, Robert K
2018-07-01
Noise-induced hearing loss is one of the most common occupational hazards in the United States. Several studies have described noise-induced hearing loss in patients following mastoidectomy. Although otolaryngologists care for patients with noise-induced hearing loss, few studies in the English literature have examined surgeons' occupational risk. Noise dosimeters and sound level meters with octave band analyzers were used to assess noise exposure during drilling of temporal bones intraoperatively and in a lab setting. Frequency specific sound intensities were recorded. Sound produced using burrs of varying size and type were compared. Differences while drilling varying anatomic structures were assessed using drills from two manufacturers. Pure tone audiometry was performed on 7 to 10 otolaryngology residents before and after a temporal bone practicum to assess for threshold shifts. Noise exposure during otologic drilling can exceed over 100 dB for short periods of time, and is especially loud using large diameter burrs > 4 mm, with cutting as compared with diamond burrs, and while drilling denser bone such as the cortex. Intensity peaks were found at 2.5, 5, and 6.3 kHz. Drilling on the tegmen and sigmoid sinus revealed peaks at 10 and 12.5 kHz. No temporary threshold shifts were found at 3 to 6 kHz, but were found at 8 to 16 kHz, though this did not reach statistical significance. This article examines noise exposure and threshold shifts during temporal bone drilling. We were unable to find previous descriptions in the literature of measurements done while multiple people drilling simultaneously, during tranlabyrinthine surgery and a specific frequency characterization of the change in peach that appears while drilling on the tegmen. Hearing protection should be considered, which would still allow the surgeon to appreciate pitch changes associated with drilling on sensitive structures and communication with surgical team members. As professionals who specialize in promoting the restoration and preservation of hearing for others, otologic surgeons should not neglect hearing protection for themselves.
Rosas, Antonio; Peña-Melián, Angel; García-Tabernero, Antonio; Bastir, Markus; De La Rasilla, Marco
2014-12-01
Correspondence between temporal lobe sulcal pattern and bony impressions on the middle cranial fossae (MCF) was analyzed. MCF bone remains (SD-359, SD-315, and SD-1219) from the El Sidrón (Spain) neandertal site are analyzed in this context. Direct comparison of the soft and hard tissues from the same individual was studied by means of: 1) dissection of two human heads; 2) optic (white light) surface scans; 3) computed tomography and magnetic resonance of the same head. The inferior temporal sulcus and gyrus are the features most strongly influencing MCF bone surface. The Superior temporal sulcus and middle temporal and fusiform gyri also leave imprints. Temporal lobe form differs between Homo sapiens and neandertals. A wider and larger post-arcuate fossa (posterior limit of Brodmann area 20 and the anterior portion of area 37) is present in modern humans as compared to neandertals. However other traits of the MCF surface are similar in these two large-brained human groups. A conspicuous variation is appreciated in the more vertical location of the inferior temporal gyrus in H. sapiens. In parallel, structures of the lower surface of the temporal lobe are more sagittally orientated. Grooves accommodating the fusiform and the lower temporal sulci become grossly parallel to the temporal squama. These differences can be understood within the context of a supero-lateral deployment of the lobe in H. sapiens, a pattern previously identified (Bastir et al., Nat Commun 2 (2011) 588-595). Regarding dural sinus pattern, a higher incidence of petrosquamous sinus is detected in neandertal samples. © 2014 Wiley Periodicals, Inc.
Comprehension and Memory of Spatial and Temporal Event Components
2008-01-01
sitting in the leather chair listening to some music . [PROBE LAMP (filler)] He had headphones on, but Mary Agnes could still make out the lyrics. She...representation and processing of virtual spaces results in performance that is essentially identical to real spaces (e.g., Sun, Chan, & Campos , 2004) or with...that people treat virtual spaces in a manner very similar to real spaces (e.g., Sun, Chan, & Campos , 2004; Waller, Loomis, & Haun, 2004). The aim of
2009-12-01
events. Work associated with aperiodic tasks have the same statistical behavior and the same timing requirements. The timing deadlines are soft. • Sporadic...answers, but it is possible to calculate how precise the estimates are. Simulation-based performance analysis of a model includes a statistical ...to evaluate all pos- sible states in a timely manner. This is the principle reason for resorting to simulation and statistical analysis to evaluate
Is “morphodynamic equilibrium” an oxymoron?
Zhou, Zeng; Coco, Giovanni; Townend, Ian; Olabarrieta, Maitane; van der Wegen, Mick; Gong, Zheng; D'Alpaos, Andrea; Gao, Shu; Jaffe, Bruce E.; Gelfenbaum, Guy R.; He, Qing; Wang, Yaping; Lanzoni, Stefano; Wang, Zhengbing; Winterwerp, Han; Zhang, Changkuan
2017-01-01
Morphodynamic equilibrium is a widely adopted yet elusive concept in the field of geomorphology of coasts, rivers and estuaries. Based on the Exner equation, an expression of mass conservation of sediment, we distinguish three types of equilibrium defined as static and dynamic, of which two different types exist. Other expressions such as statistical and quasi-equilibrium which do not strictly satisfy the Exner conditions are also acknowledged for their practical use. The choice of a temporal scale is imperative to analyse the type of equilibrium. We discuss the difference between morphodynamic equilibrium in the “real world” (nature) and the “virtual world” (model). Modelling studies rely on simplifications of the real world and lead to understanding of process interactions. A variety of factors affect the use of virtual-world predictions in the real world (e.g., variability in environmental drivers and variability in the setting) so that the concept of morphodynamic equilibrium should be mathematically unequivocal in the virtual world and interpreted over the appropriate spatial and temporal scale in the real world. We draw examples from estuarine settings which are subject to various governing factors which broadly include hydrodynamics, sedimentology and landscape setting. Following the traditional “tide-wave-river” ternary diagram, we summarize studies to date that explore the “virtual world”, discuss the type of equilibrium reached and how it relates to the real world.
Schleich, Jean-Marc; Dillenseger, Jean-Louis; Houyel, Lucile; Almange, Claude; Anderson, Robert H
2009-01-01
Learning embryology remains difficult, since it requires understanding of many complex phenomena. The temporal evolution of developmental events has classically been illustrated using cartoons, which create difficulty in linking spatial and temporal aspects, such correlation being the keystone of descriptive embryology. We synthesized the bibliographic data from recent studies of atrial septal development. On the basis of this synthesis, consensus on the stages of atrial septation as seen in the human heart has been reached by a group of experts in cardiac embryology and pediatric cardiology. This has permitted the preparation of three-dimensional (3D) computer graphic objects for the anatomical components involved in the different stages of normal human atrial septation. We have provided a virtual guide to the process of normal atrial septation, the animation providing an appreciation of the temporal and morphologic events necessary to separate the systemic and pulmonary venous returns. We have shown that our animations of normal human atrial septation increase significantly the teaching of the complex developmental processes involved, and provide a new dynamic for the process of learning.
Ma, Jinjin; Smietana, Michael J.; Kostrominova, Tatiana Y.; Wojtys, Edward M.; Larkin, Lisa M.
2012-01-01
The anterior cruciate ligament (ACL), a major stabilizer of the knee, is commonly injured. Because of its intrinsic poor healing ability, a torn ACL is usually reconstructed by a graft. We developed a multi-phasic, or bone–ligament–bone, tissue-engineered construct for ACL grafts using bone marrow stromal cells and sheep as a model system. After 6 months in vivo, the constructs increased in cross section and exhibited a well-organized microstructure, native bone integration, a functional enthesis, vascularization, innervation, increased collagen content, and structural alignment. The constructs increased in stiffness to 52% of the tangent modulus and 95% of the geometric stiffness of native ACL. The viscoelastic response of the explants was virtually indistinguishable from that of adult ACL. These results suggest that our constructs after implantation can obtain physiologically relevant structural and functional characteristics comparable to those of adult ACL. They present a viable option for ACL replacement. PMID:21902608
Zhou, Guangwei; Schwartz, Lynn Thomas; Gopen, Quinton
2009-02-01
To identify the occurrence of inner ear structural anomalies and conductive hearing loss (CHL) in children with Apert syndrome. Retrospective review. Pediatric tertiary referral center. Twenty pediatric patients with Apert syndrome were found; all patients (38/40 ears) had inner ear anomalies. Computerized tomography of the head/temporal bone, pure-tone (including air and bone conduction) audiometry, and tympanometry. Imaging demonstrating inner ear anomalies, including malformations of the cochlea, dilated vestibule, and/or semicircular canal; audiologic findings of air-bone gap(s). Hearing loss was found in 90% of the patients with Apert syndrome, and 80% of them had CHL. Air-bone gaps were found at all frequencies, with larger gaps at low frequencies. Fifty percent (20/40) of the ears had better than 0 dB hearing level bone conduction thresholds at 250 and/or 500 Hz. Normal middle ear pressure and mobility were found in all ears with intact eardrum. Inner ear anomalies were found in all patients, and 90% of them had bilateral involvement. Most frequently observed inner ear anomalies were dilated vestibule, malformed lateral semicircular canal, and cochlear dysplasia. Children with Apert syndrome may present with significant CHL that cannot be explained by minor middle ear pathologies alone. This conductive loss may be, at least partially, attributed to the inner ear anomalies; however, these structural anomalies are usually not recognized in these patients. Failure to close air-bone gap after surgical intervention may raise the suspicion of inner ear anomalies, and computed tomographic scan of the temporal bone can provide definitive proof.
Micro-endoscopic ear anatomy of guinea pig applied to experimental surgery.
Barros, Bruno Borges de Carvalho; Andrade, José Santos Cruz de; Garcia, Leandro Borborema; Pifaia, Gustavo Ribeiro; Cruz, Oswaldo Laércio Mendonça; Onishi, Ektor Tsuneo; Penido, Norma de Oliveira
2014-01-01
To describe topographic and endoscopic anatomy of guinea pig ear for development of surgical approaches in experimental studies. Experimental study. Eight adult guinea pigs (Cavia porcellus) were used in this study. Four animals were described through endoscopic view and four animals were used to describe topographic anatomy. The main structures of middle ear were well identified through endoscopy view: oval and round window, ossicles and vascular structures. Temporal bone position, landmarks and its relations to skull are perceived with topographic description. Topographic anatomic description allowed exposition of temporal bone relations for external surgical approaches. Alternatively, grooves and middle ear structures were identified and may be used to transcanal accesses.
Philippe, B
2013-08-01
This paper describes a new type of miniplate system that is designed and custom made during virtual surgery planning based on an individual patient's osteotomy. These miniplates are prefabricated with commercially pure porous titanium using direct metal laser sintering. The principles that guide the conception and production of this new miniplate are presented. The surgical procedure from the stage of virtual surgery planning until the final Le Fort I osteotomy and bone fixation are described using a case example. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Shim, Vickie B; Hunter, Peter J; Pivonka, Peter; Fernandez, Justin W
2011-12-01
The initiation of osteoarthritis (OA) has been linked to the onset and progression of pathologic mechanisms at the cartilage-bone interface. Most importantly, this degenerative disease involves cross-talk between the cartilage and subchondral bone environments, so an informative model should contain the complete complex. In order to evaluate this process, we have developed a multiscale model using the open-source ontologies developed for the Physiome Project with cartilage and bone descriptions at the cellular, micro, and macro levels. In this way, we can effectively model the influence of whole body loadings at the macro level and the influence of bone organization and architecture at the micro level, and have cell level processes that determine bone and cartilage remodeling. Cell information is then passed up the spatial scales to modify micro architecture and provide a macro spatial characterization of cartilage inflammation. We evaluate the framework by linking a common knee injury (anterior cruciate ligament deficiency) to proinflammatory mediators as a possible pathway to initiate OA. This framework provides a "virtual bone-cartilage" tool for evaluating hypotheses, treatment effects, and disease onset to inform and strengthen clinical studies.
Scaling in Theropod Dinosaurs: Femoral Bone Dimensions
ERIC Educational Resources Information Center
Lee, Scott A.
2014-01-01
Finding topics that inspire students is an important aspect of any physics course. Virtually everyone is fascinated by "Tyrannosaurus rex," and the excitement of the class is palpable when we explore scaling effects in "T. rex" and other bipedal theropod dinosaurs as part of our discussion of mechanics and elasticity. In this…
New predictive model for monitoring bone remodeling.
Bougherara, Habiba; Klika, Václav; Marsík, Frantisek; Marík, Ivo A; Yahia, L'hocine
2010-10-01
The aim of this article was to present a new thermodynamic-based model for bone remodeling which is able to predict the functional adaptation of bone in response to changes in both mechanical and biochemical environments. The model was based on chemical kinetics and irreversible thermodynamic principles, in which bone is considered as a self-organizing system that exchanges matter, energy and entropy with its surroundings. The governing equations of the mathematical model have been numerically solved using Matlab software and implemented in ANSYS software using the Finite Element Method. With the aid of this model, the whole inner structure of bone was elucidated. The current model suggested that bone remodeling was a dynamic process which was driven by mechanical loading, metabolic factors and other external contributions. The model clearly indicated that in the absence of mechanical stimulus, the bone was not completely resorbed and reaches a new steady state after about 50% of bone loss. This finding agreed with previous clinical studies. Furthermore, results of virtual computations of bone density in a composite femur showed the development of a dense cortical bone around the medullary canal and a dense trabeculae bone between the femoral head and the calcar region of the medial cortex due to compressive stresses. The comparison of the predicted bone density with the structure of the proximal femur obtained from X-rays and using strain energy density gave credibility to the current model. Copyright 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
Cochlear implantation in patients with bilateral cochlear trauma.
Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar
2010-01-01
Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.
Monsanto, Rafael da Costa; Schachern, Patricia; Paparella, Michael M; Cureoglu, Sebahattin; Penido, Norma de Oliveira
2017-08-01
Our study aimed to evaluate pathologic changes in the cochlear (inner and outer hair cells and stria vascularis) and vestibular (vestibular hair cells, dark, and transitional cells) sensorial elements in temporal bones from donors who had otitis media. We studied 40 temporal bones from such donors, which were categorized in serous otitis media (SOM), serous-purulent otitis media (SPOM), mucoid/mucoid-purulent otitis media (MOM/MPOM), and chronic otitis media (COM); control group comprised 10 nondiseased temporal bones. We found significant loss of inner and outer cochlear hair cells in the basal turn of the SPOM, MOM/MPOM and COM groups; significant loss of vestibular hair cells was observed in the MOM/MPOM and COM groups. All otitis media groups had smaller mean area of the stria vascularis in the basal turn of the cochlea when compared to controls. In conclusion, our study demonstrated more severe pathologic changes in the later stages of the continuum of otitis media (MOM/MPOM and COM). Those changes seem to progress from the basal turn of the cochlea (stria vascularis, then inner and outer hair cells) to the middle turn of the cochlea and to the saccule and utricle in the MOM/MPOM and COM stages. Copyright © 2017 Elsevier B.V. All rights reserved.
A MEMS Condenser Microphone-Based Intracochlear Acoustic Receiver.
Pfiffner, Flurin; Prochazka, Lukas; Peus, Dominik; Dobrev, Ivo; Dalbert, Adrian; Sim, Jae Hoon; Kesterke, Rahel; Walraevens, Joris; Harris, Francesca; Roosli, Christof; Obrist, Dominik; Huber, Alexander
2017-10-01
Intracochlear sound pressure (ICSP) measurements are limited by the small dimensions of the human inner ear and the requirements imposed by the liquid medium. A robust intracochlear acoustic receiver (ICAR) for repeated use with a simple data acquisition system that provides the required high sensitivity and small dimensions does not yet exist. The work described in this report aims to fill this gap and presents a new microelectromechanical systems (MEMS) condenser microphone (CMIC)-based ICAR concept suitable for ICSP measurements in human temporal bones. The ICAR head consisted of a passive protective diaphragm (PD) sealing the MEMS CMIC against the liquid medium, enabling insertion into the inner ear. The components of the MEMS CMIC-based ICAR were expressed by a lumped element model (LEM) and compared to the performance of successfully fabricated ICARs. Good agreement was achieved between the LEM and the measurements with different sizes of the PD. The ICSP measurements in a human cadaver temporal bone yielded data in agreement with the literature. Our results confirm that the presented MEMS CMIC-based ICAR is a promising technology for measuring ICSP in human temporal bones in the audible frequency range. A sensor for evaluation of the biomechanical hearing process by quantification of ICSP is presented. The concept has potential as an acoustic receiver in totally implantable cochlear implants.
Computed tomographic imaging of stapes implants.
Warren, Frank M; Riggs, Sterling; Wiggins, Richard H
2008-08-01
Computed tomographic (CT) imaging of stapes prostheses is inaccurate. Clinical situations arise in which it would be helpful to determine the depth of penetration of a stapes prosthesis into the vestibule. The accuracy of CT imaging for this purpose has not been defined. This study was aimed to determine the accuracy of CT imaging to predict the depth of intrusion of stapes prostheses into the vestibule. The measurement of stapes prostheses by CT scan was compared with physical measurements in 8 cadaveric temporal bones. The depth of intrusion into the vestibule of the piston was underestimated in specimens with the fluoroplastic piston by a mean of 0.5 mm when compared with the measurements obtained in the temporal bones. The depth of penetration of the stainless steel implant was overestimated by 0.5 mm when compared with that in the temporal bone. The type of implant must be taken into consideration when estimating the depth of penetration into the vestibule using CT scanning because the imaging characteristics of the implanted materials differ. The position of fluoroplastic pistons cannot be accurately measured in the vestibule. Metallic implants are well visualized, and measurements exceeding 2.2 mm increase the suspicion of otolithic impingement. Special reconstructions along the length of the piston may be more accurate in estimating the position of stapes implants.
Simplified Summative Temporal Bone Dissection Scale Demonstrates Equivalence to Existing Measures.
Pisa, Justyn; Gousseau, Michael; Mowat, Stephanie; Westerberg, Brian; Unger, Bert; Hochman, Jordan B
2018-01-01
Emphasis on patient safety has created the need for quality assessment of fundamental surgical skills. Existing temporal bone rating scales are laborious, subject to evaluator fatigue, and contain inconsistencies when conferring points. To address these deficiencies, a novel binary assessment tool was designed and validated against a well-established rating scale. Residents completed a mastoidectomy with posterior tympanotomy on identical 3D-printed temporal bone models. Four neurotologists evaluated each specimen using a validated scale (Welling) and a newly developed "CanadaWest" scale, with scoring repeated after a 4-week interval. Nineteen participants were clustered into junior, intermediate, and senior cohorts. An ANOVA found significant differences between performance of the junior-intermediate and junior-senior cohorts for both Welling and CanadaWest scales ( P < .05). Neither scale found a significant difference between intermediate-senior resident performance ( P > .05). Cohen's kappa found strong intrarater reliability (0.711) with a high degree of interrater reliability of (0.858) for the CanadaWest scale, similar to scores on the Welling scale of (0.713) and (0.917), respectively. The CanadaWest scale was facile and delineated performance by experience level with strong intrarater reliability. Comparable to the validated Welling Scale, it distinguished junior from senior trainees but was challenged in differentiating intermediate and senior trainee performance.
Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.
Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M
2017-07-01
To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.
Thomas, Thaddeus P.; Anderson, Donald D.; Willis, Andrew R.; Liu, Pengcheng; Marsh, J. Lawrence; Brown, Thomas D.
2010-01-01
Background Highly comminuted intra-articular fractures are complex and difficult injuries to treat. Once emergent care is rendered, the definitive treatment objective is to restore the original anatomy while minimizing surgically induced trauma. Operations that use limited or percutaneous approaches help preserve tissue vitality, but reduced visibility makes reconstruction more difficult. A pre-operative plan of how comminuted fragments would best be re-positioned to restore anatomy helps in executing a successful reduction. Methods In this study, methods for virtually reconstructing a tibial plafond fracture were developed and applied to clinical cases. Building upon previous benchtop work, novel image analysis techniques and puzzle solving algorithms were developed for clinical application. Specialty image analysis tools were used to segment the fracture fragment geometries from CT data. The original anatomy was then restored by matching fragment native (periosteal and subchondral) bone surfaces to an intact template, generated from the uninjured contralateral limb. Findings Virtual reconstructions obtained for ten tibial plafond fracture cases had average alignment errors of 0.39 (0.5 standard deviation) mm. In addition to precise reduction planning, 3D puzzle solutions can help identify articular deformities and bone loss. Interpretation The results from this study indicate that 3D puzzle solving provides a powerful new tool for planning the surgical reconstruction of comminuted articular fractures. PMID:21215501
NASA Astrophysics Data System (ADS)
Zheng, Guoyan
2007-03-01
Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.
VirSSPA- a virtual reality tool for surgical planning workflow.
Suárez, C; Acha, B; Serrano, C; Parra, C; Gómez, T
2009-03-01
A virtual reality tool, called VirSSPA, was developed to optimize the planning of surgical processes. Segmentation algorithms for Computed Tomography (CT) images: a region growing procedure was used for soft tissues and a thresholding algorithm was implemented to segment bones. The algorithms operate semiautomati- cally since they only need seed selection with the mouse on each tissue segmented by the user. The novelty of the paper is the adaptation of an enhancement method based on histogram thresholding applied to CT images for surgical planning, which simplifies subsequent segmentation. A substantial improvement of the virtual reality tool VirSSPA was obtained with these algorithms. VirSSPA was used to optimize surgical planning, to decrease the time spent on surgical planning and to improve operative results. The success rate increases due to surgeons being able to see the exact extent of the patient's ailment. This tool can decrease operating room time, thus resulting in reduced costs. Virtual simulation was effective for optimizing surgical planning, which could, consequently, result in improved outcomes with reduced costs.
Patibandla, Mohana Rao; Thotakura, Amit Kumar; Rao, Marabathina Nageswara; Addagada, Gokul Chowdary; Nukavarapu, Manisha Chowdary; Panigrahi, Manas Kumar; Uppin, Shantiveer; Challa, Sundaram; Dandamudi, Srinivas
2017-01-01
Giant-cell tumor (GCT) involving the skull base is rare. Sphenoid bone is the most commonly involved bone followed by petrous temporal bone. Histopathology and radiological features of these lesions are similar to GCT involving bone elsewhere. Unlike other sites, skull base is not an ideal site for the radical surgery. Hence adjuvant treatment has pivotal role. Radiation therapy with intensity-modulated radiation therapy, stereotactic radiosurgery or chemotherapy with adriamycin are promising as described in some case reports. Bisphosphonates showed good control in local recurrence. In vitro studies with Zolendronate loaded bone cement and phase 2 trials of Denosumab showed hopeful results, may be useful in future. PMID:28413541
Schiuma, D; Brianza, S; Tami, A E
2011-03-01
A method was developed to improve the design of locking implants by finding the optimal paths for the anchoring elements, based on a high resolution pQCT assessment of local bone mineral density (BMD) distribution and bone micro-architecture (BMA). The method consists of three steps: (1) partial fixation of the implant to the bone and creation of a reference system, (2) implant removal and pQCT scan of the bone, and (3) determination of BMD and BMA of all implant-anchoring locations along the actual and alternative directions. Using a PHILOS plate, the method uncertainty was tested on an artificial humerus bone model. A cadaveric humerus was used to quantify how the uncertainty of the method affects the assessment of bone parameters. BMD and BMA were determined along four possible alternative screw paths as possible criteria for implant optimization. The method is biased by a 0.87 ± 0.12 mm systematic uncertainty and by a 0.44 ± 0.09 mm random uncertainty in locating the virtual screw position. This study shows that this method can be used to find alternative directions for the anchoring elements, which may possess better bone properties. This modification will thus produce an optimized implant design. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
The temporal response of bone to unloading
NASA Technical Reports Server (NTRS)
Globus, R. K.; Bikle, D. D.; Morey-Holton, E.
1984-01-01
Rats were suspended by their tails with the forelimbs bearing the weight load to simulate the weightlessness of space flight. Growth in bone mass ceased by 1 week in the hindlimbs and lumbar vertebrae in growing rats, while growth in the forelimbs and cervical vertebrae remained unaffected. The effects of selective skeletal unloading on bone formation during 2 weeks of suspension was investigated using radio iostope incorporation (with Ca-45 and H-3 proline) and histomorphometry (with tetracycline labeling). The results of these studies were confirmed by histomorphometric measurements of bone formation using triple tetracycline labeling. This model of simulated weightlessness results in an initial inhibition of bone formation in the unloaded bones. This temporary cessation of bone formation is followed in the accretion of bone mass, which then resumes at a normal rate by 14 days, despite continued skeletal unloading. This cycle of inhibition and resumption of bone formation has profound implication for understanding bone dynamics durng space flight, immobilization, or bed rest and offers an opportunity to study the hormonal and mechanical factors that regulate bone formation.
Subtemporal-anterior transtentoral approach to middle cranial fossa microsurgical anatomy.
Xu, Zhiming; Wang, Weimin; Zhang, Jingjing; Liu, Wei; Feng, Yugong; Li, Gang
2014-11-01
This study aimed to describe the topography of inferior and external dura mater of the middle cranial fossa through subtemporal-anterior transpetrosal approach and discuss the feasibility of improving the approach. Eight formalin-fixed adult cadaveric heads were studied, with the bones milled away in the lateral triangle region of the petrous bone, Kawase rhombus region, and inner triangle region of the petrous apex. The distances between the targets in these regions, as well as the angles after the dissection of zygomatic arch, were measured, and then the exposed petroclival and retrochiasmatic areas were observed under the microscope. There were significant variations in the distances between targets in the 3 milled regions among the specimens. After the dissection of zygomatic arch, the surgical view got an average increase of 12 degrees. The subtemporal anterior transpetrosal approach, as an improved subtemporal approach, can expose the lesions optimally, causing no injury to the hearing and reducing injuries to temporal lobe. On the other hand, the lateral bone of the petrous parts of the temporal bone is removed so as to improve the view to the retrochiasmatic area and expand the operative field.
Karki, S; Pokharel, M; Suwal, S; Poudel, R
Background The exact role of High resolution computed tomography (HRCT) temporal bone in preoperative assessment of Chronic suppurative otitis media atticoantral disease still remains controversial. Objective To evaluate the role of high resolution computed tomography temporal bone in Chronic suppurative otitis media atticoantral disease and to compare preoperative computed tomographic findings with intra-operative findings. Method Prospective, analytical study conducted among 65 patients with chronic suppurative otitis media atticoantral disease in Department of Radiodiagnosis, Kathmandu University Dhulikhel Hospital between January 2015 to July 2016. The operative findings were compared with results of imaging. The parameters of comparison were erosion of ossicles, scutum, facial canal, lateral semicircular canal, sigmoid and tegmen plate along with extension of disease to sinus tympani and facial recess. Sensitivity, specificity, negative predictive value, positive predictive values were calculated. Result High resolution computed tomography temporal bone offered sensitivity (Se) and specificity (Sp) of 100% for visualization of sigmoid and tegmen plate erosion. The performance of HRCT in detecting malleus (Se=100%, Sp=95.23%), incus (Se=100%,Sp=80.48%) and stapes (Se=96.55%, Sp=71.42%) erosion was excellent. It offered precise information about facial canal erosion (Se=100%, Sp=75%), scutum erosion (Se=100%, Sp=96.87%) and extension of disease to facial recess and sinus tympani (Se=83.33%,Sp=100%). high resolution computed tomography showed specificity of 100% for lateral semicircular canal erosion (Sp=100%) but with low sensitivity (Se=53.84%). Conclusion The findings of high resolution computed tomography and intra-operative findings were well comparable except for lateral semicircular canal erosion. high resolution computed tomography temporal bone acts as a road map for surgeon to identify the extent of disease, plan for appropriate procedure that is required and prepare for potential complications that can be encountered during surgery.
Su, Diya; Li, Dezhi; Wang, Shiwei; Qiao, Hui; Li, Ping; Wang, Binbin; Wan, Hong; Schumacher, Michael; Liu, Song
2018-06-06
Closed temporal bone fractures due to cranial trauma often result in facial nerve injury, frequently inducing incomplete facial paralysis. Conventional hypoglossal-facial nerve end-to-end neurorrhaphy may not be suitable for these injuries because sacrifice of the lesioned facial nerve for neurorrhaphy destroys the remnant axons and/or potential spontaneous innervation. we modified the classical method by hypoglossal-facial nerve "side"-to-side neurorrhaphy using an interpositional predegenerated nerve graft to treat these injuries. Five patients who experienced facial paralysis resulting from closed temporal bone fractures due to cranial trauma were treated with the "side"-to-side neurorrhaphy. An additional 4 patients did not receive the neurorrhaphy and served as controls. Before treatment, all patients had suffered House-Brackmann (H-B) grade V or VI facial paralysis for a mean of 5 months. During the 12-30 months of follow-up period, no further detectable deficits were observed, but an improvement in facial nerve function was evidenced over time in the 5 neurorrhaphy-treated patients. At the end of follow-up, the improved facial function reached H-B grade II in 3, grade III in 1 and grade IV in 1 of the 5 patients, consistent with the electrophysiological examinations. In the control group, two patients showed slightly spontaneous innervation with facial function improved from H-B grade VI to V, and the other patients remained unchanged at H-B grade V or VI. We concluded that the hypoglossal-facial nerve "side"-to-side neurorrhaphy can preserve the injured facial nerve and is suitable for treating significant incomplete facial paralysis resulting from closed temporal bone fractures, providing an evident beneficial effect. Moreover, this treatment may be performed earlier after the onset of facial paralysis in order to reduce the unfavorable changes to the injured facial nerve and atrophy of its target muscles due to long-term denervation and allow axonal regrowth in a rich supportive environment.
Real-time fusion of endoscopic views with dynamic 3-D cardiac images: a phantom study.
Szpala, Stanislaw; Wierzbicki, Marcin; Guiraudon, Gerard; Peters, Terry M
2005-09-01
Minimally invasive robotically assisted cardiac surgical systems currently do not routinely employ 3-D image guidance. However, preoperative magnetic resonance and computed tomography (CT) images have the potential to be used in this role, if appropriately registered with the patient anatomy and animated synchronously with the motion of the actual heart. This paper discusses the fusion of optical images of a beating heart phantom obtained from an optically tracked endoscope, with volumetric images of the phantom created from a dynamic CT dataset. High quality preoperative dynamic CT images are created by first extracting the motion parameters of the heart from the series of temporal frames, and then applying this information to animate a high-quality heart image acquired at end systole. Temporal synchronization of the endoscopic and CT model is achieved by selecting the appropriate CT image from the dynamic set, based on an electrocardiographic trigger signal. The spatial error between the optical and virtual images is 1.4 +/- 1.1 mm, while the time discrepancy is typically 50-100 ms. Index Terms-Image guidance, image warping, minimally invasive cardiac surgery, virtual endoscopy, virtual reality.
Malignant external otitis: early scintigraphic detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.
1984-02-01
Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive inmore » one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis.« less
Noninvasive diagnosis of uremic osteodystrophy: uses and limitations.
Heaf, J G; Joffe, P; Pødenphant, J; Andersen, J R
1987-01-01
45 bone biopsies from patients with chronic uremia were reviewed to define which noninvasive investigations were of value in predicting the histological diagnosis and to quantify the spectrum of uremic bone disease at a center that has consistently used an aluminum-free dialysis bath. 17 biopsies were taken postmortem. 15 patients received conservative treatment, the rest were on maintenance dialysis. 13 patients had symptomatic bone disease. Virtually all patients with a uremia duration greater than 3 years had uremic osteodystrophy. All patients with clinical bone disease, hypercalcemia or raised alkaline phosphatase activity had osteodystrophy, but the specific histology was not indicated. Greatly raised parathyroid levels suggested secondary hyperparathyroidism, but the test was only 100% specific when 20 times normal. Total aluminum consumption was highly indicative of bone aluminum concentration (p less than 0.0001) and aluminum-related osteomalacia (5 cases), suggesting that a considerable proportion of uremic bone disease is iatrogenic. Serum aluminum was of some use in the diagnosis of aluminum-related osteomalacia, but was not wholly reliable. Bone mineral content (BMC) using both forearm measurements and total body bone mineral levels (TBBM) were assessed in 32 patients and were found to be reduced in 12, with a preponderance of secondary hyperparathyroidism. BMC and TBBM were negatively correlated to resorbing surfaces and bone formation rate, suggesting that secondary hyperparathyroidism is the uremic bone disease that represents the greatest threat to bone mass. It is concluded that while noninvasive investigations give considerable information, reliable diagnosis requires the use of histological methods.
Novelli, Giorgio; Gramegna, Marco; Tonellini, Gabriele; Valente, Gabriella; Boni, Pietro; Bozzetti, Alberto; Sozzi, Davide
2016-09-01
Osteoblastoma is a benign tumor of bone, representing less than 1% of bone tumors. Craniomaxillofacial localizations account for up to 15% of the total and frequently involve the posterior mandible. Endo-orbital localization is very rare, with most occurring in young patients. Very few of these tumors become malignant. Orbital localization requires radical removal of the tumor followed by careful surgical reconstruction of the orbit to avoid subsequent aesthetic or functional problems. Here, we present a clinical case of this condition and describe a surgical protocol that uses and integrates state-of-the art technologies to achieve orbital reconstruction.
Scaling in Theropod Dinosaurs: Femoral Bone Dimensions
NASA Astrophysics Data System (ADS)
Lee, Scott A.
2014-05-01
Finding topics that inspire students is an important aspect of any physics course. Virtually everyone is fascinated by Tyrannosaurus rex, and the excitement of the class is palpable when we explore scaling effects in T. rex and other bipedal theropod dinosaurs as part of our discussion of mechanics and elasticity. In this paper, we explore the role of longitudinal stress in the femur bones due to the weight of the dinosaur in determining how the geometry of the femur changes with size of the theropod. This is one area of allometry the study of how different biological characteristics scale with size.
Formation of blood clot on biomaterial implants influences bone healing.
Shiu, Hoi Ting; Goss, Ben; Lutton, Cameron; Crawford, Ross; Xiao, Yin
2014-12-01
The first step in bone healing is forming a blood clot at injured bones. During bone implantation, biomaterials unavoidably come into direct contact with blood, leading to a blood clot formation on its surface prior to bone regeneration. Despite both situations being similar in forming a blood clot at the defect site, most research in bone tissue engineering virtually ignores the important role of a blood clot in supporting healing. Dental implantology has long demonstrated that the fibrin structure and cellular content of a peri-implant clot can greatly affect osteoconduction and de novo bone formation on implant surfaces. This article reviews the formation of a blood clot during bone healing in relation to the use of platelet-rich plasma (PRP) gels. It is implicated that PRP gels are dramatically altered from a normal clot in healing, resulting in conflicting effect on bone regeneration. These results indicate that the effect of clots on bone regeneration depends on how the clots are formed. Factors that influence blood clot structure and properties in relation to bone healing are also highlighted. Such knowledge is essential for developing strategies to optimally control blood clot formation, which ultimately alter the healing microenvironment of bone. Of particular interest are modification of surface chemistry of biomaterials, which displays functional groups at varied composition for the purpose of tailoring blood coagulation activation, resultant clot fibrin architecture, rigidity, susceptibility to lysis, and growth factor release. This opens new scope of in situ blood clot modification as a promising approach in accelerating and controlling bone regeneration.
Direct radiocarbon dating and DNA analysis of the Darra-i-Kur (Afghanistan) human temporal bone.
Douka, Katerina; Slon, Viviane; Stringer, Chris; Potts, Richard; Hübner, Alexander; Meyer, Matthias; Spoor, Fred; Pääbo, Svante; Higham, Tom
2017-06-01
The temporal bone discovered in the 1960s from the Darra-i-Kur cave in Afghanistan is often cited as one of the very few Pleistocene human fossils from Central Asia. Here we report the first direct radiocarbon date for the specimen and the genetic analyses of DNA extracted and sequenced from two areas of the bone. The new radiocarbon determination places the find to ∼4500 cal BP (∼2500 BCE) contradicting an assumed Palaeolithic age of ∼30,000 years, as originally suggested. The DNA retrieved from the specimen originates from a male individual who carried mitochondrial DNA of the modern human type. The petrous part yielded more endogenous ancient DNA molecules than the squamous part of the same bone. Molecular dating of the Darra-i-Kur mitochondrial DNA sequence corroborates the radiocarbon date and suggests that the specimen is younger than previously thought. Taken together, the results consolidate the fact that the human bone is not associated with the Pleistocene-age deposits of Darra-i-Kur; instead it is intrusive, possibly re-deposited from upper levels dating to much later periods (Neolithic). Despite its Holocene age, the Darra-i-Kur specimen is, so far, the first and only ancient human from Afghanistan whose DNA has been sequenced. Copyright © 2017 Elsevier Ltd. All rights reserved.
Feasibility and fidelity of practising surgical fixation on a virtual ulna bone
LeBlanc, Justin; Hutchison, Carol; Hu, Yaoping; Donnon, Tyrone
2013-01-01
Background Surgical simulators provide a safe environment to learn and practise psychomotor skills. A goal for these simulators is to achieve high levels of fidelity. The purpose of this study was to develop a reliable surgical simulator fidelity questionnaire and to assess whether a newly developed virtual haptic simulator for fixation of an ulna has comparable levels of fidelity as Sawbones. Methods Simulator fidelity questionnaires were developed. We performed a stratified randomized study with surgical trainees. They performed fixation of the ulna using a virtual simulator and Sawbones. They completed the fidelity questionnaires after each procedure. Results Twenty-two trainees participated in the study. The reliability of the fidelity questionnaire for each separate domain (environment, equipment, psychological) was Cronbach α greater than 0.70, except for virtual environment. The Sawbones had significantly higher levels of fidelity than the virtual simulator (p < 0.001) with a large effect size difference (Cohen d < 1.3). Conclusion The newly developed fidelity questionnaire is a reliable tool that can potentially be used to determine the fidelity of other surgical simulators. Increasing the fidelity of this virtual simulator is required before its use as a training tool for surgical fixation. The virtual simulator brings with it the added benefits of repeated, independent safe use with immediate, objective feedback and the potential to alter the complexity of the skill. PMID:23883510
A weak Hamiltonian finite element method for optimal control problems
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Bless, Robert R.
1989-01-01
A temporal finite element method based on a mixed form of the Hamiltonian weak principle is developed for dynamics and optimal control problems. The mixed form of Hamilton's weak principle contains both displacements and momenta as primary variables that are expanded in terms of nodal values and simple polynomial shape functions. Unlike other forms of Hamilton's principle, however, time derivatives of the momenta and displacements do not appear therein; instead, only the virtual momenta and virtual displacements are differentiated with respect to time. Based on the duality that is observed to exist between the mixed form of Hamilton's weak principle and variational principles governing classical optimal control problems, a temporal finite element formulation of the latter can be developed in a rather straightforward manner. Several well-known problems in dynamics and optimal control are illustrated. The example dynamics problem involves a time-marching problem. As optimal control examples, elementary trajectory optimization problems are treated.
A weak Hamiltonian finite element method for optimal control problems
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Bless, Robert R.
1990-01-01
A temporal finite element method based on a mixed form of the Hamiltonian weak principle is developed for dynamics and optimal control problems. The mixed form of Hamilton's weak principle contains both displacements and momenta as primary variables that are expanded in terms of nodal values and simple polynomial shape functions. Unlike other forms of Hamilton's principle, however, time derivatives of the momenta and displacements do not appear therein; instead, only the virtual momenta and virtual displacements are differentiated with respect to time. Based on the duality that is observed to exist between the mixed form of Hamilton's weak principle and variational principles governing classical optimal control problems, a temporal finite element formulation of the latter can be developed in a rather straightforward manner. Several well-known problems in dynamics and optimal control are illustrated. The example dynamics problem involves a time-marching problem. As optimal control examples, elementary trajectory optimization problems are treated.
Weak Hamiltonian finite element method for optimal control problems
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Bless, Robert R.
1991-01-01
A temporal finite element method based on a mixed form of the Hamiltonian weak principle is developed for dynamics and optimal control problems. The mixed form of Hamilton's weak principle contains both displacements and momenta as primary variables that are expanded in terms of nodal values and simple polynomial shape functions. Unlike other forms of Hamilton's principle, however, time derivatives of the momenta and displacements do not appear therein; instead, only the virtual momenta and virtual displacements are differentiated with respect to time. Based on the duality that is observed to exist between the mixed form of Hamilton's weak principle and variational principles governing classical optimal control problems, a temporal finite element formulation of the latter can be developed in a rather straightforward manner. Several well-known problems in dynamics and optimal control are illustrated. The example dynamics problem involves a time-marching problem. As optimal control examples, elementary trajectory optimization problems are treated.
Stereoscopic virtual reality models for planning tumor resection in the sellar region.
Wang, Shou-sen; Zhang, Shang-ming; Jing, Jun-jie
2012-11-28
It is difficult for neurosurgeons to perceive the complex three-dimensional anatomical relationships in the sellar region. To investigate the value of using a virtual reality system for planning resection of sellar region tumors. The study included 60 patients with sellar tumors. All patients underwent computed tomography angiography, MRI-T1W1, and contrast enhanced MRI-T1W1 image sequence scanning. The CT and MRI scanning data were collected and then imported into a Dextroscope imaging workstation, a virtual reality system that allows structures to be viewed stereoscopically. During preoperative assessment, typical images for each patient were chosen and printed out for use by the surgeons as references during surgery. All sellar tumor models clearly displayed bone, the internal carotid artery, circle of Willis and its branches, the optic nerve and chiasm, ventricular system, tumor, brain, soft tissue and adjacent structures. Depending on the location of the tumors, we simulated the transmononasal sphenoid sinus approach, transpterional approach, and other approaches. Eleven surgeons who used virtual reality models completed a survey questionnaire. Nine of the participants said that the virtual reality images were superior to other images but that other images needed to be used in combination with the virtual reality images. The three-dimensional virtual reality models were helpful for individualized planning of surgery in the sellar region. Virtual reality appears to be promising as a valuable tool for sellar region surgery in the future.
Mohanty, Sujata; Rani, Amita; Urs, A B; Dabas, Jitender
2014-10-01
Aggressive osteoblastoma is a rare osteoid tissue forming tumour commonly affecting the spine with predilection for the posterior elements. Calvarial involvement is extremely rare with only two reported cases in the literature. Due to its overlapping clinical, radiographic and histological features with ossifying fibroma, benign osteoblastoma and osteosarcoma, it is very difficult accurately to diagnose this lesion at an early stage. A rare case of an aggressive osteoblastoma of the squamous temporal bone in a young male is presented here which was misdiagnosed twice before reaching the final diagnosis by correlating clinical, radiographic and histopathological features. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Carter, Melissa T; Blaser, Susan; Papsin, Blake; Meschino, Wendy; Reardon, Willie; Klatt, Regan; Babul-Hirji, Riyana; Milunsky, Jeff; Chitayat, David
2012-08-01
Hearing impairment is common in individuals with branchio-oculo-facial (BOF) syndrome. The majority of described individuals have conductive hearing impairment due to malformed ossicles and/or external canal stenosis or atresia, although a sensorineural component to the hearing impairment in BOF syndrome is increasingly being reported. Sophisticated computed tomography (CT) of the temporal bone has revealed middle and inner ear malformations in three previous reports. We present middle and inner ear abnormalities in three additional individuals with mutation-proven BOF syndrome. We suggest that temporal bone CT imaging be included in the medical workup of a child with BOF syndrome, in order to guide management. Copyright © 2012 Wiley Periodicals, Inc.
Structural Controllability and Controlling Centrality of Temporal Networks
Pan, Yujian; Li, Xiang
2014-01-01
Temporal networks are such networks where nodes and interactions may appear and disappear at various time scales. With the evidence of ubiquity of temporal networks in our economy, nature and society, it's urgent and significant to focus on its structural controllability as well as the corresponding characteristics, which nowadays is still an untouched topic. We develop graphic tools to study the structural controllability as well as its characteristics, identifying the intrinsic mechanism of the ability of individuals in controlling a dynamic and large-scale temporal network. Classifying temporal trees of a temporal network into different types, we give (both upper and lower) analytical bounds of the controlling centrality, which are verified by numerical simulations of both artificial and empirical temporal networks. We find that the positive relationship between aggregated degree and controlling centrality as well as the scale-free distribution of node's controlling centrality are virtually independent of the time scale and types of datasets, meaning the inherent robustness and heterogeneity of the controlling centrality of nodes within temporal networks. PMID:24747676
Penetrating brain injury caused by nail guns: two case reports and a review of the literature.
Luo, Wei; Liu, Hai; Hao, Shuyu; Zhang, Ying; Li, Jingsheng; Liu, Baiyun
2012-01-01
To the best of the authors' knowledge, there are few case reports of penetrating brain injuries (PBI) caused by nail guns and these have usually involved incomplete penetration of the skull. Complete penetration of a nail into the intracranial cavity is extremely rare. Here, two such cases are presented. In the first, the nail entered through the right temporal bone, lodged in the right temporal lobe and was removed via craniotomy with intra-operative ultrasound guidance. In the second, the nail destroyed the left parietal bone, damaged the left internal capsule and lodged in the left temporal lobe near the left petrous apex and the brain stem. According to the latest literature retrieval, this is the first reported case of nail-gun injury to the internal capsule. The position of the nail precluded removal without further neurologic damage. Treatment strategies designed to optimize outcome, with or without surgery, and possible complications are discussed in this report.
Flesh and Bone: Information Literacy, Teaching, and the Connected Classroom.
ERIC Educational Resources Information Center
Lant, Kathleen Margaret
This paper discusses information literacy, teaching, and online technology. The first section introduces the split between mind and body that is made possible by the Internet and related resources. The second section discusses distance learning, including the impact of digital environments in teaching, and the power of virtual education to permit…
Metric Sex Determination of the Human Coxal Bone on a Virtual Sample using Decision Trees.
Savall, Frédéric; Faruch-Bilfeld, Marie; Dedouit, Fabrice; Sans, Nicolas; Rousseau, Hervé; Rougé, Daniel; Telmon, Norbert
2015-11-01
Decision trees provide an alternative to multivariate discriminant analysis, which is still the most commonly used in anthropometric studies. Our study analyzed the metric characterization of a recent virtual sample of 113 coxal bones using decision trees for sex determination. From 17 osteometric type I landmarks, a dataset was built with five classic distances traditionally reported in the literature and six new distances selected using the two-step ratio method. A ten-fold cross-validation was performed, and a decision tree was established on two subsamples (training and test sets). The decision tree established on the training set included three nodes and its application to the test set correctly classified 92% of individuals. This percentage was similar to the data of the literature. The usefulness of decision trees has been demonstrated in numerous fields. They have been already used in sex determination, body mass prediction, and ancestry estimation. This study shows another use of decision trees enabling simple and accurate sex determination. © 2015 American Academy of Forensic Sciences.
MIKOS, ANTONIOS G.; HERRING, SUSAN W.; OCHAREON, PANNEE; ELISSEEFF, JENNIFER; LU, HELEN H.; KANDEL, RITA; SCHOEN, FREDERICK J.; TONER, MEHMET; MOONEY, DAVID; ATALA, ANTHONY; VAN DYKE, MARK E.; KAPLAN, DAVID; VUNJAK-NOVAKOVIC, GORDANA
2010-01-01
This article summarizes the views expressed at the third session of the workshop “Tissue Engineering—The Next Generation,” which was devoted to the engineering of complex tissue structures. Antonios Mikos described the engineering of complex oral and craniofacial tissues as a “guided interplay” between biomaterial scaffolds, growth factors, and local cell populations toward the restoration of the original architecture and function of complex tissues. Susan Herring, reviewing osteogenesis and vasculogenesis, explained that the vascular arrangement precedes and dictates the architecture of the new bone, and proposed that engineering of osseous tissues might benefit from preconstruction of an appropriate vasculature. Jennifer Elisseeff explored the formation of complex tissue structures based on the example of stratified cartilage engineered using stem cells and hydrogels. Helen Lu discussed engineering of tissue interfaces, a problem critical for biological fixation of tendons and ligaments, and the development of a new generation of fixation devices. Rita Kandel discussed the challenges related to the re-creation of the cartilage-bone interface, in the context of tissue engineered joint repair. Frederick Schoen emphasized, in the context of heart valve engineering, the need for including the requirements derived from “adult biology” of tissue remodeling and establishing reliable early predictors of success or failure of tissue engineered implants. Mehmet Toner presented a review of biopreservation techniques and stressed that a new breakthrough in this field may be necessary to meet all the needs of tissue engineering. David Mooney described systems providing temporal and spatial regulation of growth factor availability, which may find utility in virtually all tissue engineering and regeneration applications, including directed in vitro and in vivo vascularization of tissues. Anthony Atala offered a clinician’s perspective for functional tissue regeneration, and discussed new biomaterials that can be used to develop new regenerative technologies. PMID:17518671
Using virtual reality to train children in safe street-crossing skills.
Schwebel, David C; McClure, Leslie A
2010-02-01
Pedestrian injuries are among the leading causes of morbidity and mortality in middle childhood. One limitation to existing pedestrian safety interventions is that they do not provide children with repeated practice needed to develop the complex perceptual and cognitive skills required for safe street crossing. Virtual reality offers training through repeated unsupervised practice without risk, automated feedback on success of crossings, adjustment of traffic to match children's skill and a fun, appealing environment for training. To test the efficacy of virtual reality to train child pedestrians in safe street crossing. Birmingham, Alabama, USA. A randomised controlled trial is underway with an expected sample of four groups of 60 children aged 7-8 years (total N=240). One group receives training in an interactive, immersive virtual pedestrian environment. A second receives pedestrian safety training via widely used video and computer strategies. The third group receives what is judged to be the most efficacious treatment currently available, individualised behavioural training at streetside locations. The fourth group serves as a no-contact control group. All participants are exposed to a range of field and laboratory-based measures of pedestrian skill during baseline and post-intervention visits, as well as during a 6-month follow-up assessment. Primary analyses will be conducted through linear mixed models testing change over time in the four intervention groups. Three pedestrian safety measures will serve as primary outcomes: temporal gap before initiating crossing, temporal gap remaining after crossing and attention to traffic while waiting to cross.
Stadelmann, Vincent A; Zderic, Ivan; Baur, Annick; Unholz, Cynthia; Eberli, Ursula; Gueorguiev, Boyko
2016-02-01
Vertebroplasty has been shown to reinforce weak vertebral bodies and reduce fracture risks, yet cement leakage is a major problem that can cause severe complications. Since cement flow is nearly impossible to control during surgery, small volumes of cement are injected, but then mechanical benefits might be limited. A better understanding of cement flows within bone structure is required to further optimize vertebroplasty and bone augmentation in general. We developed a novel imaging method, composite time-lapse CT, to characterize cement flow during injection. In brief, composite-resolution time-lapse CT exploits the qualities of microCT and clinical CT. The method consists in overlaying low-resolution time-lapse CT scans acquired during injection onto pre-operative high-resolution microCT scans, generating composite-resolution time-lapse CT series of cement flow within bone. In this in vitro study, composite-resolution time-lapse CT was applied to eight intact and five artificially fractured cadaveric vertebrae during vertebroplasty. The time-lapse scans were acquired at one-milliliter cement injection steps until a total of 10 ml cement was injected. The composite-resolution series were then converted into micro finite element models to compute strains distribution under virtual axial loading. Relocation of strain energy density within bone structure was observed throughout the progression of the procedure. Interestingly, the normalized effect of cement injection on the overall stiffness of the vertebrae was similar between intact and fractured specimens, although at different orders of magnitude. In conclusion, composite time-lapse CT can picture cement flows during bone augmentation. The composite images can also be easily converted into finite element models to compute virtual strain distributions under loading at every step of an injection, providing deeper understanding on the biomechanics of vertebroplasty. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
2015-01-01
Background. The aims of this study were to investigate the ridge contour anterior to the nasopalatine canal, and the difference between the incidences of the nasopalatine canal perforation in dentate and partially edentulous patients by cone-beam computed tomography. Methods. Cone-beam computed tomography scan images from 72 patients were selected from database and divided into dentate and partially edentulous groups. The configuration of the ridge anterior to the canal including palatal concavity depth, palatal concavity height, palatal concavity angle, bone height coronal to the incisive foramen, and bone width anterior to the canal was measured. A virtual implant placement procedure was used, and the incidences of perforation were evaluated after implant placement in the cingulum position with the long axis along with the designed crown. Results. Comparing with variable values from dentate patients, the palatal concavity depth and angle were greater by 0.9 mm and 4°, and bone height was shorter by 1.1 mm in partially edentulous patients, respectively. Bone width in edentulous patients was narrower than in dentate patients by 1.2 mm at incisive foramen level and 0.9 mm at 8 mm subcrestal level, respectively. After 72 virtual cylindrical implants (4.1 × 12 mm) were placed, a total of 12 sites (16.7%) showed a perforation and three-fourths occurred in partially edentulous patients. After replacing with 72 tapered implants (4.3 × 13 mm), only 6 implants (8.3%) broke into the canal in the partially edentulous patient group. Conclusions. The nasopalatine canal may get close to the implant site and the bone width anterior to the canal decreases after the central incisor extraction. The incidence of nasopalatine canal perforation may occur more commonly during delayed implant placement in central incisor missing patients. PMID:26557434
Anchieta, M V M; Salles, F A; Cassaro, B D; Quaresma, M M; Santos, B F O
2016-10-01
Presentation of a new cranioplasty technique employing a combination of two technologies: rapid prototyping and surgical navigation. This technique allows the reconstruction of the skull cap after the resection of a bone tumor in a single surgical time. The neurosurgeon plans the craniotomy previously on the EximiusMed software, compatible with the Eximius Surgical Navigator, both from the company Artis Tecnologia (Brazil). The navigator imports the planning and guides the surgeon during the craniotomy. The simulation of the bone fault allows the virtual reconstruction of the skull cap and the production of a personalized modelling mold using the Magics-Materialise (Belgium)-software. The mold and a replica of the bone fault are made by rapid prototyping by the company Artis Tecnologia (Brazil) and shipped under sterile conditions to the surgical center. The PMMA prosthesis is produced during the surgical act with the help of a hand press. The total time necessary for the planning and production of the modelling mold is four days. The precision of the mold is submillimetric and accurately reproduces the virtual reconstruction of the prosthesis. The production of the prosthesis during surgery takes until twenty minutes depending on the type of PMMA used. The modelling mold avoids contraction and dissipates the heat generated by the material's exothermic reaction in the polymerization phase. The craniectomy is performed with precision over the drawing made with the help of the Eximius Surgical Navigator, according to the planned measurements. The replica of the bone fault serves to evaluate the adaptation of the prosthesis as a support for the perforations and the placement of screws and fixation plates, as per the surgeon's discretion. This technique allows the adequate oncologic treatment associated with a satisfactory aesthetic result, with precision, in a single surgical time, reducing time and costs.
Cosmetic reconstruction of temporal defect following pterional [corrected] craniotomy.
Badie, B
1996-04-01
Depression of the temporal fossa that is often caused by atrophy of the temporalis muscle or superficial temporal fat pad may be an unavoidable defect following pterional craniotomy. Various techniques have been previously described to correct this disfiguring defect. Most techniques, however, require drilling holes into the cranium or the synthetic grafts for attachment of the temporalis muscle. A simple method is described by which a temporal fossa depression is repaired with methylmethacrylate bone cement and a new superior temporal line is created for attachment of the temporalis muscle without the need to drill suture holes into the acrylic or the cranium. The technique described has been used on several patients with excellent cosmetic outcome.
Massberg, Steffen; Konrad, Ildiko; Schürzinger, Katrin; Lorenz, Michael; Schneider, Simon; Zohlnhoefer, Dietlind; Hoppe, Katharina; Schiemann, Matthias; Kennerknecht, Elisabeth; Sauer, Susanne; Schulz, Christian; Kerstan, Sandra; Rudelius, Martina; Seidl, Stefan; Sorge, Falko; Langer, Harald; Peluso, Mario; Goyal, Pankaj; Vestweber, Dietmar; Emambokus, Nikla R.; Busch, Dirk H.; Frampton, Jon; Gawaz, Meinrad
2006-01-01
The accumulation of smooth muscle and endothelial cells is essential for remodeling and repair of injured blood vessel walls. Bone marrow–derived progenitor cells have been implicated in vascular repair and remodeling; however, the mechanisms underlying their recruitment to the site of injury remain elusive. Here, using real-time in vivo fluorescence microscopy, we show that platelets provide the critical signal that recruits CD34+ bone marrow cells and c-Kit+ Sca-1+ Lin− bone marrow–derived progenitor cells to sites of vascular injury. Correspondingly, specific inhibition of platelet adhesion virtually abrogated the accumulation of both CD34+ and c-Kit+ Sca-1+ Lin− bone marrow–derived progenitor cells at sites of endothelial disruption. Binding of bone marrow cells to platelets involves both P-selectin and GPIIb integrin on platelets. Unexpectedly, we found that activated platelets secrete the chemokine SDF-1α, thereby supporting further primary adhesion and migration of progenitor cells. These findings establish the platelet as a major player in the initiation of vascular remodeling, a process of fundamental importance for vascular repair and pathological remodeling after vascular injury. PMID:16618794
Massberg, Steffen; Konrad, Ildiko; Schürzinger, Katrin; Lorenz, Michael; Schneider, Simon; Zohlnhoefer, Dietlind; Hoppe, Katharina; Schiemann, Matthias; Kennerknecht, Elisabeth; Sauer, Susanne; Schulz, Christian; Kerstan, Sandra; Rudelius, Martina; Seidl, Stefan; Sorge, Falko; Langer, Harald; Peluso, Mario; Goyal, Pankaj; Vestweber, Dietmar; Emambokus, Nikla R; Busch, Dirk H; Frampton, Jon; Gawaz, Meinrad
2006-05-15
The accumulation of smooth muscle and endothelial cells is essential for remodeling and repair of injured blood vessel walls. Bone marrow-derived progenitor cells have been implicated in vascular repair and remodeling; however, the mechanisms underlying their recruitment to the site of injury remain elusive. Here, using real-time in vivo fluorescence microscopy, we show that platelets provide the critical signal that recruits CD34+ bone marrow cells and c-Kit+ Sca-1+ Lin- bone marrow-derived progenitor cells to sites of vascular injury. Correspondingly, specific inhibition of platelet adhesion virtually abrogated the accumulation of both CD34+ and c-Kit+ Sca-1+ Lin- bone marrow-derived progenitor cells at sites of endothelial disruption. Binding of bone marrow cells to platelets involves both P-selectin and GPIIb integrin on platelets. Unexpectedly, we found that activated platelets secrete the chemokine SDF-1alpha, thereby supporting further primary adhesion and migration of progenitor cells. These findings establish the platelet as a major player in the initiation of vascular remodeling, a process of fundamental importance for vascular repair and pathological remodeling after vascular injury.
Mechanical model of orthopaedic drilling for augmented-haptics-based training.
Pourkand, Ashkan; Zamani, Naghmeh; Grow, David
2017-10-01
In this study, augmented-haptic feedback is used to combine a physical object with virtual elements in order to simulate anatomic variability in bone. This requires generating levels of force/torque consistent with clinical bone drilling, which exceed the capabilities of commercially available haptic devices. Accurate total force generation is facilitated by a predictive model of axial force during simulated orthopaedic drilling. This model is informed by kinematic data collected while drilling into synthetic bone samples using an instrumented linkage attached to the orthopaedic drill. Axial force is measured using a force sensor incorporated into the bone fixture. A nonlinear function, relating force to axial position and velocity, was used to fit the data. The normalized root-mean-square error (RMSE) of forces predicted by the model compared to those measured experimentally was 0.11 N across various bones with significant differences in geometry and density. This suggests that a predictive model can be used to capture relevant variations in the thickness and hardness of cortical and cancellous bone. The practical performance of this approach is measured using the Phantom Premium haptic device, with some required customizations. Copyright © 2017 Elsevier Ltd. All rights reserved.
2014-12-01
Introduction 1.1 Background In today’s world of high -tech warfare, we have developed the ability to deploy virtually any type of ordnance quickly and... ANSI Std. 239–18 i THIS PAGE INTENTIONALLY LEFT BLANK ii Approved for public release; distribution is unlimited TEMPORALLY ADJUSTED COMPLEX AMBIGUITY...this time due to time constraints and the high computational complexity involved in the current implementation of the Moss algorithm. Full maps, with
Schleich, Jean-Marc; Dillenseger, Jean-Louis; Houyel, Lucile; Almange, Claude; Anderson, Robert H.
2009-01-01
Background Learning embryology remains difficult, since it requires understanding of many complex phenomena. The temporal evolution of developmental events has classically been illustrated using cartoons, which create difficulty in linking spatial and temporal aspects, such correlation being the keystone of descriptive embryology. Methods We synthesized the bibliographic data from recent studies of atrial septal development. On the basis of this synthesis, consensus on the stages of atrial septation as seen in the human heart has been reached by a group of experts in cardiac embryology and paediatric cardiology. This has permitted the preparation of three-dimensional (3-D) computer graphic objects for the anatomical components involved in the different stages of normal human atrial septation. Results We have provided a virtual guide to the process of normal atrial septation, the animation providing an appreciation of the temporal and morphologic events necessary to separate the systemic and pulmonary venous returns. Conclusion We have shown that our animations of normal human atrial septation increase significantly the teaching of the complex developmental processes involved, and provide a new dynamic for the process of learning. PMID:19363807
[Black bone disease of the skull and facial bones].
Laure, B; Petraud, A; Sury, F; Bayol, J-C; Marquet-Van Der Mee, N; de Pinieux, G; Goga, D
2009-11-01
We report the case of a patient with a craniofacial black bone disease. This was discovered accidentally during a coronal approach. A 38-year-old patient was referred to our unit for facial palsy having appeared 10 years before. Rehabilitation of the facial palsy was performed with a lengthening temporal myoplasty and lengthening of the upper eyelid elevator. An unusual black color of the skull was observed at incision of the coronal approach. Subperiostal dissection of skull and malars confirmed the presence of a black bone disease. A postoperative history revealed minocycline intake (200mg per day) during 3 years. This craniofacial black bone disease was caused by minocycline intake. The originality of this case is to see directly the entire craniofacial skeleton black. This abnormal pigmentation may affect various organs or tissues. Bone pigmentation is irreversible unlike that of the mouth mucosa or of the skin. This abnormal pigmentation is usually discovered accidentally.
MANIU, ALMA; CATANA, IULIU V.; HARABAGIU, OANA; PETRI, MARIA; COSGAREA, MARCEL
2013-01-01
Aim The aim of this article is to review the anatomy of middle ear compartments and folds and to demonstrate through anatomical evidence their presence at birth. Additionally, their role in the obstructions of middle ear ventilatory pathway is highlighted. Methods Ninety-eight adult temporal bones, with no history of auricular disease and fifteen newborn temporal bones were studied by micro dissection. Documentation was done by color photography using the operation microscope Results Our micro-dissections have showed that mucosal folds from the middle ear are steadily present since birth, given that they were found in all newborn temporal bones. The mucosal folds in our normal adult material, showed some variations including membrane defects but they were constantly present. Our micro dissections showed that the epitympanic diaphragm consisted, in addition to malleal ligamental folds and ossicles, of only two constantly present folds: the tensor tympani fold and the incudomalleal fold. When the tensor fold is complete the only ventilation pathway to the anterior epitympanic space is through the isthmus, whereas its absence creates an efficient additional aeration route from the Eustachian tube to the epitympanum. Conclusions The goal of surgery in the chronic pathology of the middle ear should be restoration of normal ventilation of the attical-mastoid area. This is possible by removing the tensor fold and restoring the functionality of the isthmus tympani. PMID:26527977
Pathologic Changes of the Peripheral Vestibular System Secondary to Chronic Otitis Media.
da Costa Monsanto, Rafael; Erdil, Mehmet; Pauna, Henrique F; Kwon, Geeyoun; Schachern, Patricia A; Tsuprun, Vladimir; Paparella, Michael M; Cureoglu, Sebahattin
2016-09-01
To evaluate the histopathologic changes of dark, transitional, and hair cells of the vestibular system in human temporal bones from patients with chronic otitis media. Comparative human temporal bone study. Otopathology laboratory. To compare the density of vestibular dark, transitional, and hair cells in temporal bones with and without chronic otitis media, we used differential interference contrast microscopy. In the chronic otitis media group (as compared with the age-matched control group), the density of type I and type II hair cells was significantly decreased in the lateral semicircular canal, saccule, and utricle (P < .05). The density of type I cells was also significantly decreased in the chronic otitis media group in the posterior semicircular canal (P = .005), but that of type II cells was not (P = .168). The mean number of dark cells was significantly decreased in the chronic otitis media group in the lateral semicircular canal (P = .014) and in the posterior semicircular canal (P = .002). We observed no statistically significant difference in the density of transitional cells between the 2 groups (P > .1). The findings of our study suggest that the decrease in the number of vestibular sensory cells and dark cells could be the cause of the clinical symptoms of imbalance of some patients with chronic otitis media. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
Evidence against the mucosal traction theory in cholesteatoma.
Pauna, Henrique F; Monsanto, Rafael C; Schachern, Patricia; Paparella, Michael M; Chole, Richard A; Cureoglu, Sebahattin
2017-10-08
To investigate the distribution of ciliated epithelium in the human middle ear and its potential role in the formation of cholesteatoma. Comparative human temporal bone study. We selected temporal bones from 14 donors with a diagnosis of cholesteatoma, 15 with chronic otitis media without retraction pockets, 14 with chronic otitis media with retraction pockets, 14 with cystic fibrosis (CF), and 16 controls. We mapped the distribution of the ciliated cells in the mucosal lining of the middle ear and tympanic membrane using three-dimensional reconstruction analysis, and counted the number of ciliated cells in the middle ear mucosa. Ciliated cells are extremely sparse in the epithelial lining of the lateral surface of the ossicles in the epitympanum and the medial surface of the tympanic membrane. Furthermore, there is a significant decrease in the number of ciliated cells in these areas in temporal bones with cholesteatoma, chronic otitis media, chronic otitis media with retraction pockets, and CF compared to controls. Ciliated cells most commonly are located at the hypotympanum and the Eustachian tube opening but not the tympanic membrane or epitympanum. The paucity of ciliated epithelial cells on the medial side of the tympanic membrane and the lateral surface of the ossicles in the epitympanum in cases with cholesteatoma and/or chronic otitis media do not support the mucosal migration theory of cholesteatoma formation. NA. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Thor, Andreas; Palmquist, Anders; Hirsch, Jan-Michaél; Rännar, Lars-Erik; Dérand, Per; Omar, Omar
2016-10-01
There is limited information on the biological status of bone regenerated with microvascular fibula flap combined with biomaterials. This paper describes the clinical, histological, ultrastructural, and molecular picture of bone regenerated with patient-customized plate, used for mandibular reconstruction in combination with microvascular osteomyocutaneous fibula flap. The plate was virtually planned and additively manufactured using electron beam melting. This plate was retrieved from the patient after 33 months. Microcomputed tomography, backscattered-scanning electron microscopy, histology, and quantitative-polymerase chain reaction were employed to evaluate the regenerated bone and the flap bone associated with the retrieved plate. At retrieval, the posterior two-thirds of the plate were in close adaptation with the underlying flap, whereas soft tissue was observed between the native mandible and the anterior one-third. The histological and structural analyses showed new bone regeneration, ingrowth, and osseointegration of the posterior two-thirds. The histological observations were supported by the gene expression analysis showing higher expression of bone formation and remodeling genes under the posterior two-thirds compared with the anterior one-third of the plate. The observation of osteocytes in the flap indicated its viability. The present data endorse the suitability of the customized, additively manufactured plate for the vascularized fibula mandibular reconstruction. Furthermore, the combination of the analytical techniques provides possibilities to deduce the structural and molecular characteristics of bone regenerated using this procedure.
The effect of brain tomography findings on mortality in sniper shot head injuries.
Can, Çağdaş; Bolatkale, M; Sarıhan, A; Savran, Y; Acara, A Ç; Bulut, M
2017-06-01
Penetrating gunshot head injuries have a poor prognosis and require prompt care. Brain CT is a routine component of the standard evaluation of head wounds and suspected brain injury. We aimed to investigate the effect of brain CT findings on mortality in gunshot head injury patients who were admitted to our emergency department (ED) from the Syrian Civil War. The study group comprised patients who were admitted to the ED with gunshot brain injury. Patients' GCS scores, prehospital intubations and brain CT findings were examined. 104 patients were included (92% male, mean age 25 years). Pneumocephalus, midline shift, penetrating head injury, patients with GCS scores ≤6 and patients who had to be intubated in the prehospital period were associated with higher mortality (p<0.05). The results of this study demonstrated that pneumocephalus, midline shift, a penetrating head injury, GCS scores ≤6 and prehospital intubation are associated with high mortality, whereas patients with temporal bone fracture, perforating or single cerebral lobe head injury had a higher survival rates. The temporal bone has a relatively thin and smooth shape compared with the other skull bones so a bullet is less fragmented when it has penetrated the temporal bone, which could be a reason for the reduced cavitation effect. In perforating head injury, the bullet makes a second hole and so will have deposited less energy than a retained bullet with a consequent reduction in intracranial injury and mortality. Further studies are required to reach definitive conclusions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Dietz, Aarno; Gazibegovic, Dzemal; Tervaniemi, Jyrki; Vartiainen, Veli-Matti; Löppönen, Heikki
2016-12-01
The aim of this study was to evaluate the insertion results and placement of the new Advanced Bionics HiFocus Mid-Scala (HFms) electrode array, inserted through the round window membrane, in eight fresh human temporal bones using cone beam computed tomography (CBCT). Pre- and post-insertion CBCT scans were registered to create a 3D reconstruction of the cochlea with the array inserted. With an image fusion technique both the bony edges of the cochlea and the electrode array in situ could accurately be determined, thus enabling to identify the exact position of the electrode array within the scala tympani. Vertical and horizontal scalar location was measured at four points along the cochlea base at an angular insertion depth of 90°, 180° and 270° and at electrode 16, the most basal electrode. Smooth insertion through the round window membrane was possible in all temporal bones. The imaging results showed that there were no dislocations from the scala tympani into the scala vestibule. The HFms electrode was positioned in the middle of the scala along the whole electrode array in three out of the eight bones and in 62 % of the individual locations measured along the base of the cochlea. In only one cochlea a close proximity of the electrode with the basilar membrane was observed, indicating possible contact with the basilar membrane. The results and assessments presented in this study appear to be highly accurate. Although a further validation including histopathology is needed, the image fusion technique described in this study represents currently the most accurate method for intracochlear electrode assessment obtainable with CBCT.
Sclerosteosis involving the temporal bone: histopathologic aspects.
Nager, G T; Hamersma, H
1986-01-01
Sclerosteosis is a rare, potentially lethal, autosomal recessive, progressive craniotubular sclerosing bone dysplasia with characteristic facial and skeletal features. The temporal bone changes include a marked increase in overall size, extensive sclerosis, narrowing of the external auditory canal, and severe constriction of the internal auditory meatus, fallopian canal, eustachian tube, and middle ear cleft. Attenuation of the bony canals of the 9th, 10th, and 11th cranial nerves, reduction in size of the internal carotid artery, and severe obliteration of the sigmoid sinus and jugular bulb also occur. Loss of hearing, generally bilateral, is a frequent symptom. It often manifests in early childhood and initially is expressed as sound conduction impairment. Later, a sensorineural hearing loss and loss of vestibular nerve function often develop. Impairment of facial nerve function is another feature occasionally present at birth. In the beginning, a unilateral intermittent facial weakness may occur which eventually progresses to a bilateral permanent facial paresis. The histologic examination of the temporal bones from a patient with sclerosteosis explains the mechanisms involved in the progressive impairment of sound conduction and loss of cochlear, vestibular, and facial nerve function. There is a decrease of the arterial blood supply to the brain and an obstruction of the venous drainage from it. The histopathology reveals the obstacles to decompression of the middle ear cleft, ossicular chain, internal auditory and facial canals, and the risks, and in many instances the contraindications, to such procedures. On the other hand, decompression of the sigmoid sinus and jugular bulb should be considered as an additional life-saving procedure in conjunction with the prophylactic craniotomy recommended in all adult patients.
2014-01-01
Background It is generally believed that malignant gliomas never metastasize outside the central nervous system (CNS). However, the notion that oligodendrogliomas (OGDs) cells cannot spread outside CNS is being challenged. Methods We described in detail the clinical story of one patient with anaplastic OGD, which metastasized to lymph nodes, bone marrowand bones Genetic analyses included detection of 1p and 19q chromosomal arms, methylation status of MGMT promoter, and PTEN exon mutations. A search of worldwide literature was conducted for reports of metastatic OGDs using NCBI-PubMed, with the keywords “extracranial”, “extraneural”, “oligodendroglioma”, “oligodendrogliomas”, “metastatic”, “metastasis”, and “metastases”, in different combinations. Results An open biopsy of the infiltrated bones in our patient revealed that malignant cells had replaced the patient’s marrow. Moreover, the diagnosis of multiple-organ metastases of anaplastic OGD was confirmed based on immunohistochemical staining. Genetic analyses showed that the tumors originated from previously resected brain lesions. None of the lesions had 1p and 19q deletions, but hypermethylation of MGMT promoter, and the G → A transversion at codon 234 of PTEN exon 2 were detected. Literatures review yielded 60 reports of metastatic OGDs from 1951 to the present, which with our patient makes 61 cases. Concerning these 61 patients, there were 110 infiltrated sites correlated closely with primary OGDs. The most frequent metastatic sites were bone and bone marrow (n = 47; 42.7%), lymph nodes (n = 22; 20.0%), liver (n = 7; 6.4%), scalp (n = 6; 5.5%), lung (n = 6; 5.5%), pleura (n = 4; 3.6%), chest wall (n = 3; 2.7%), iliopsoas muscle (n = 2; 1.8%), soft tissue (n = 2; 1.8%), and parotid gland (n = 2; 1.8%). Conclusions Extracranial metastases in anaplastic OGD are very rare but they do occur; bone and bone marrow may be the most common sites. Detection of certain molecular markers such as deletion of 1p and 19q chromosomal arms, hypermethylation of MGMT promoter, and characteristic PTEN exon mutations may help differentiate subtypes which are more prone to extracranial metastases. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/8749838611478560. PMID:24447608
Using additive manufacturing in accuracy evaluation of reconstructions from computed tomography.
Smith, Erin J; Anstey, Joseph A; Venne, Gabriel; Ellis, Randy E
2013-05-01
Bone models derived from patient imaging and fabricated using additive manufacturing technology have many potential uses including surgical planning, training, and research. This study evaluated the accuracy of bone surface reconstruction of two diarthrodial joints, the hip and shoulder, from computed tomography. Image segmentation of the tomographic series was used to develop a three-dimensional virtual model, which was fabricated using fused deposition modelling. Laser scanning was used to compare cadaver bones, printed models, and intermediate segmentations. The overall bone reconstruction process had a reproducibility of 0.3 ± 0.4 mm. Production of the model had an accuracy of 0.1 ± 0.1 mm, while the segmentation had an accuracy of 0.3 ± 0.4 mm, indicating that segmentation accuracy was the key factor in reconstruction. Generally, the shape of the articular surfaces was reproduced accurately, with poorer accuracy near the periphery of the articular surfaces, particularly in regions with periosteum covering and where osteophytes were apparent.
New tools for sculpting cranial implants in a shared haptic augmented reality environment.
Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary
2006-01-01
New volumetric tools were developed for the design and fabrication of high quality cranial implants from patient CT data. These virtual tools replace time consuming physical sculpting, mold making and casting steps. The implant is designed by medical professionals in tele-immersive collaboration. Virtual clay is added in the virtual defect area on the CT data using the adding tool. With force feedback the modeler can feel the edge of the defect and fill only the space where no bone is present. A carving tool and a smoothing tool are then used to sculpt and refine the implant. To make a physical evaluation, the skull with simulated defect and the implant are fabricated via stereolithography to allow neurosurgeons to evaluate the quality of the implant. Initial tests demonstrate a very high quality fit. These new haptic volumetric sculpting tools are a critical component of a comprehensive tele-immersive system.
Kinematic evaluation of virtual walking trajectories.
Cirio, Gabriel; Olivier, Anne-Hélène; Marchal, Maud; Pettré, Julien
2013-04-01
Virtual walking, a fundamental task in Virtual Reality (VR), is greatly influenced by the locomotion interface being used, by the specificities of input and output devices, and by the way the virtual environment is represented. No matter how virtual walking is controlled, the generation of realistic virtual trajectories is absolutely required for some applications, especially those dedicated to the study of walking behaviors in VR, navigation through virtual places for architecture, rehabilitation and training. Previous studies focused on evaluating the realism of locomotion trajectories have mostly considered the result of the locomotion task (efficiency, accuracy) and its subjective perception (presence, cybersickness). Few focused on the locomotion trajectory itself, but in situation of geometrically constrained task. In this paper, we study the realism of unconstrained trajectories produced during virtual walking by addressing the following question: did the user reach his destination by virtually walking along a trajectory he would have followed in similar real conditions? To this end, we propose a comprehensive evaluation framework consisting on a set of trajectographical criteria and a locomotion model to generate reference trajectories. We consider a simple locomotion task where users walk between two oriented points in space. The travel path is analyzed both geometrically and temporally in comparison to simulated reference trajectories. In addition, we demonstrate the framework over a user study which considered an initial set of common and frequent virtual walking conditions, namely different input devices, output display devices, control laws, and visualization modalities. The study provides insight into the relative contributions of each condition to the overall realism of the resulting virtual trajectories.
Surface mesh to voxel data registration for patient-specific anatomical modeling
NASA Astrophysics Data System (ADS)
de Oliveira, Júlia E. E.; Giessler, Paul; Keszei, András.; Herrler, Andreas; Deserno, Thomas M.
2016-03-01
Virtual Physiological Human (VPH) models are frequently used for training, planning, and performing medical procedures. The Regional Anaesthesia Simulator and Assistant (RASimAs) project has the goal of increasing the application and effectiveness of regional anesthesia (RA) by combining a simulator of ultrasound-guided and electrical nerve-stimulated RA procedures and a subject-specific assistance system through an integration of image processing, physiological models, subject-specific data, and virtual reality. Individualized models enrich the virtual training tools for learning and improving regional anaesthesia (RA) skills. Therefore, we suggest patient-specific VPH models that are composed by registering the general mesh-based models with patient voxel data-based recordings. Specifically, the pelvis region has been focused for the support of the femoral nerve block. The processing pipeline is composed of different freely available toolboxes such as MatLab, the open Simulation framework (SOFA), and MeshLab. The approach of Gilles is applied for mesh-to-voxel registration. Personalized VPH models include anatomical as well as mechanical properties of the tissues. Two commercial VPH models (Zygote and Anatomium) were used together with 34 MRI data sets. Results are presented for the skin surface and pelvic bones. Future work will extend the registration procedure to cope with all model tissue (i.e., skin, muscle, bone, vessel, nerve, fascia) in a one-step procedure and extrapolating the personalized models to body regions actually being out of the captured field of view.
Saint-Pierre, H. Y.; Teuscher, E.; Paul, M.; Bergeron, R.
1984-01-01
Following the oral administration of a magnet to a cow, a perforation of the pharyngeal mucosa occurred. The magnet underwent encapsulation in the vicinity of the stylohyoid bone. The subsequent osteitis gradually extended to the temporal bone, where another abscess developed. The cardiac signs resulting from the irritation of the vagus nerve by the first abscess and the nervous signs associated with the intracranial pressure due to the second abscess are described. ImagesFigure 1. PMID:17422402
Dawson, Lindsay A.; Yu, Ling; Yan, Mingquan; Marrero, Luis; Schanes, Paula P.; Dolan, Connor; Pela, Maegan; Petersen, Britta; Han, Manjong
2017-01-01
Abstract Regeneration of mammalian limbs is restricted to amputation of the distal digit tip, the terminal phalanx (P3). The adjacent skeletal element, the middle phalanx (P2), has emerged as a model system to investigate regenerative failure and as a site to test approaches aimed at enhancing regeneration. We report that exogenous application of bone morphogenetic protein 2 (BMP2) stimulates the formation of a transient cartilaginous callus distal to the amputation plane that mediates the regeneration of the amputated P2 bone. BMP2 initiates a significant regeneration response during the periosteal‐derived cartilaginous healing phase of P2 bone repair, yet fails to induce regeneration in the absence of periosteal tissue, or after boney callus formation. We provide evidence that a temporal component exists in the induced regeneration of P2 that we define as the “regeneration window.” In this window, cells are transiently responsive to BMP2 after the amputation injury. Simple re‐injury of the healed P2 stump acts to reinitiate endogenous bone repair, complete with periosteal chondrogenesis, thus reopening the “regeneration window” and thereby recreating a regeneration‐permissive environment that is responsive to exogenous BMP2 treatment. PMID:28975034
Fluid volume displacement at the oval and round windows with air and bone conduction stimulation.
Stenfelt, Stefan; Hato, Naohito; Goode, Richard L
2004-02-01
The fluids in the cochlea are normally considered incompressible, and the fluid volume displacement of the oval window (OW) and the round window (RW) should be equal and of opposite phase. However, other channels, such as the cochlear and vestibular aqueducts, may affect the fluid flow. To test if the OW and RW fluid flows are equal and of opposite phase, the volume displacement was assessed by multiple point measurement at the windows with a laser Doppler vibrometer. This was done during air conduction (AC) stimulation in seven fresh human temporal bones, and with bone conduction (BC) stimulation in eight temporal bones and one human cadaver head. With AC stimulation, the average volume displacement of the two windows is within 3 dB, and the phase difference is close to 180 degrees for the frequency range 0.1 to 10 kHz. With BC stimulation, the average volume displacement difference between the two windows is greater: below 2 kHz, the volume displacement at the RW is 5 to 15 dB greater than at the OW and above 2 kHz more fluid is displaced at the OW. With BC stimulation, lesions at the OW caused only minor changes of the fluid flow at the RW.
Fluid volume displacement at the oval and round windows with air and bone conduction stimulation
NASA Astrophysics Data System (ADS)
Stenfelt, Stefan; Hato, Naohito; Goode, Richard L.
2004-02-01
The fluids in the cochlea are normally considered incompressible, and the fluid volume displacement of the oval window (OW) and the round window (RW) should be equal and of opposite phase. However, other channels, such as the cochlear and vestibular aqueducts, may affect the fluid flow. To test if the OW and RW fluid flows are equal and of opposite phase, the volume displacement was assessed by multiple point measurement at the windows with a laser Doppler vibrometer. This was done during air conduction (AC) stimulation in seven fresh human temporal bones, and with bone conduction (BC) stimulation in eight temporal bones and one human cadaver head. With AC stimulation, the average volume displacement of the two windows is within 3 dB, and the phase difference is close to 180° for the frequency range 0.1 to 10 kHz. With BC stimulation, the average volume displacement difference between the two windows is greater: below 2 kHz, the volume displacement at the RW is 5 to 15 dB greater than at the OW and above 2 kHz more fluid is displaced at the OW. With BC stimulation, lesions at the OW caused only minor changes of the fluid flow at the RW.
Stock density managed in real-time
USDA-ARS?s Scientific Manuscript database
The spatio-temporal management of stocking density will be possible once virtual fencing (VF) becomes a commercial reality. VF uses sensory cues (currently audio and electrical stimulation) to change an instrumented animal's forward direction of movement. Free-ranging cattle instrumented with VF e...
Epileptic phenotype of FGFR3-related bilateral medial temporal lobe dysgenesis.
Okazaki, Tetsuya; Saito, Yoshiaki; Ueda, Riyo; Awashima, Takeya; Nishimura, Yoko; Yuasa, Isao; Shinohara, Yuki; Adachi, Kaori; Sasaki, Masayuki; Nanba, Eiji; Maegaki, Yoshihiro
2017-01-01
Hypochondroplasia (HCH) is a skeletal dysplasia, characterized by short stature and macrocephaly. Clinical symptoms and radiological and histopathological features of HCH are similar, but milder than those seen in achondroplasia. Particularly, HCH patients with Asn540Lys mutation in the FGFR3 gene are reported to have medial temporal lobe dysgenesis and epilepsy. We report a 3-year-old girl who developed recurrent epileptic apnea, which started immediately after birth. The apneic seizures were refractory to antiepileptic medications; ictal electroencephalography showed rhythmic activity originating from the left or right temporal areas and rarely from the right frontal area. Macrocephaly was noted since birth. Neuroimaging revealed bilateral dysgenesis and hypometabolism of the medial temporal structures as well as perfusion changes in the left lateral temporofrontal areas during the ictal period. Clonazepam was initiated and acetazolamide dosage was increased at 6months, resulting in complete seizure control after 8months of age. Genetic analysis identified an Asn540Lys (c.1620 C>A) mutation in the FGFR3 gene. Characteristic bone findings on the lumbar spine, iliac bone, and femur were retrospectively confirmed on X-rays during infancy. This was the first report that delineated the epilepsy phenotype in FGFR3-related bilateral medial temporal lobe dysgenesis; such findings would lead to an early diagnosis and better epilepsy management. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Feely, M; Keohane, C
1984-01-01
A case of chondroblastoma of the temporal bone is reported, and the pathology of the lesion outlined. The rarity of these neoplasms in the skull makes accurate prognosis impossible. Images PMID:6512556
BARBER, H O
1965-05-01
Dizziness, whether vague or specifically rotational, is a common sequel to head injury, and is often postural. One hundred and sixty-five patients with this symptom were examined. The simple posture tests employed to detect positional nystagmus are described. This physical finding was present in one-quarter of the entire group, and in nearly one-half of cases of longitudinal fracture of temporal bone. In such cases, it is an objective finding that corresponds precisely to the patient's complaint of vertigo.Transverse fracture of temporal bone destroys the inner ear in both cochlear and vestibular parts. Longitudinal fracture is commoner and causes bleeding from the ear; inner-ear damage is usually minor.In the rare cases where persisting postural vertigo and positional nystagmus are disabling, relief of the symptom may be achieved by vestibular denervation of the affected side.
Rallis, Austin; Fercho, Kelene A; Bosch, Taylor J; Baugh, Lee A
2018-01-31
Tool use is associated with three visual streams-dorso-dorsal, ventro-dorsal, and ventral visual streams. These streams are involved in processing online motor planning, action semantics, and tool semantics features, respectively. Little is known about the way in which the brain represents virtual tools. To directly assess this question, a virtual tool paradigm was created that provided the ability to manipulate tool components in isolation of one another. During functional magnetic resonance imaging (fMRI), adult participants performed a series of virtual tool manipulation tasks in which vision and movement kinematics of the tool were manipulated. Reaction time and hand movement direction were monitored while the tasks were performed. Functional imaging revealed that activity within all three visual streams was present, in a similar pattern to what would be expected with physical tool use. However, a previously unreported network of right-hemisphere activity was found including right inferior parietal lobule, middle and superior temporal gyri and supramarginal gyrus - regions well known to be associated with tool processing within the left hemisphere. These results provide evidence that both virtual and physical tools are processed within the same brain regions, though virtual tools recruit bilateral tool processing regions to a greater extent than physical tools. Copyright © 2017 Elsevier Ltd. All rights reserved.
Time multiplexing for increased FOV and resolution in virtual reality
NASA Astrophysics Data System (ADS)
Miñano, Juan C.; Benitez, Pablo; Grabovičkić, Dejan; Zamora, Pablo; Buljan, Marina; Narasimhan, Bharathwaj
2017-06-01
We introduce a time multiplexing strategy to increase the total pixel count of the virtual image seen in a VR headset. This translates into an improvement of the pixel density or the Field of View FOV (or both) A given virtual image is displayed by generating a succession of partial real images, each representing part of the virtual image and together representing the virtual image. Each partial real image uses the full set of physical pixels available in the display. The partial real images are successively formed and combine spatially and temporally to form a virtual image viewable from the eye position. Partial real images are imaged through different optical channels depending of its time slot. Shutters or other schemes are used to avoid that a partial real image be imaged through the wrong optical channels or at the wrong time slot. This time multiplexing strategy needs real images be shown at high frame rates (>120fps). Available display and shutters technologies are discussed. Several optical designs for achieving this time multiplexing scheme in a compact format are shown. This time multiplexing scheme allows increasing the resolution/FOV of the virtual image not only by increasing the physical pixel density but also by decreasing the pixels switching time, a feature that may be simpler to achieve in certain circumstances.
NASA Astrophysics Data System (ADS)
Aubry, Alexandre; Derode, Arnaud; Padilla, Frédéric
2008-03-01
We present local measurements of the diffusion constant for ultrasonic waves undergoing multiple scattering. The experimental setup uses a coherent array of programmable transducers. By achieving Gaussian beamforming at emission and reception, an array of virtual sources and receivers located in the near field is constructed. A matrix treatment is proposed to separate the incoherent intensity from the coherent backscattering peak. Local measurements of the diffusion constant D are then achieved. This technique is applied to a real case: a sample of human trabecular bone for which the ultrasonic characterization of multiple scattering is an issue.
Kobler, Jan-Philipp; Nuelle, Kathrin; Lexow, G Jakob; Rau, Thomas S; Majdani, Omid; Kahrs, Lueder A; Kotlarski, Jens; Ortmaier, Tobias
2016-03-01
Minimally invasive cochlear implantation is a novel surgical technique which requires highly accurate guidance of a drilling tool along a trajectory from the mastoid surface toward the basal turn of the cochlea. The authors propose a passive, reconfigurable, parallel robot which can be directly attached to bone anchors implanted in a patient's skull, avoiding the need for surgical tracking systems. Prior to clinical trials, methods are necessary to patient specifically optimize the configuration of the mechanism with respect to accuracy and stability. Furthermore, the achievable accuracy has to be determined experimentally. A comprehensive error model of the proposed mechanism is established, taking into account all relevant error sources identified in previous studies. Two optimization criteria to exploit the given task redundancy and reconfigurability of the passive robot are derived from the model. The achievable accuracy of the optimized robot configurations is first estimated with the help of a Monte Carlo simulation approach and finally evaluated in drilling experiments using synthetic temporal bone specimen. Experimental results demonstrate that the bone-attached mechanism exhibits a mean targeting accuracy of [Formula: see text] mm under realistic conditions. A systematic targeting error is observed, which indicates that accurate identification of the passive robot's kinematic parameters could further reduce deviations from planned drill trajectories. The accuracy of the proposed mechanism demonstrates its suitability for minimally invasive cochlear implantation. Future work will focus on further evaluation experiments on temporal bone specimen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Francis, W.R., E-mail: w.francis@swansea.ac.uk; Owens, S.E.; Wilde, C.
2014-10-24
Highlights: • ERα36 is the predominant ERα isoform involved in bone regulation in human BMSC. • ERα36 mRNA is significantly upregulated during the process of osteogenesis. • The pattern of ERα36 and runx2 mRNA expression is similar during osteogenesis. • ERα36 appears to be co-localised with runx2 during osteogenesis. - Abstract: During bone maintenance in vivo, estrogen signals through estrogen receptor (ER)-α. The objectives of this study were to investigate the temporal expression of ERα36 and ascertain its functional relevance during osteogenesis in human bone marrow derived stromal cells (BMSC). This was assessed in relation to runt-related transcription factor-2 (runx2),more » a main modulatory protein involved in bone formation. ERα36 and runx2 subcellular localisation was assessed using immunocytochemistry, and their mRNA expression levels by real time PCR throughout the process of osteogenesis. The osteogenically induced BMSCs demonstrated a rise in ERα36 mRNA during proliferation followed by a decline in expression at day 10, which represents a change in dynamics within the culture between the proliferative stage and the differentiative stage. The mRNA expression profile of runx2 mirrored that of ERα36 and showed a degree subcellular co-localisation with ERα36. This study suggests that ERα36 is involved in the process of osteogenesis in BMSCs, which has implications in estrogen deficient environments.« less
Shen, Weimin; Cui, Jie; Chen, Jianbin; Chen, Haini; Zou, Jijun; Ji, Yi
2012-11-01
We have developed a new technique for the treatment of mild types of cryptotia in which the cavum conchae cartilage was pulled superiorly and sutured it to the temporal bone to the temporal parietal junction periosteum securely. Then, the stitches for bolster fixation were inserted parallel to the auricular temporal sulcus and temporarily left untied. Our technique is easy to use and secures a firm bolster fixation, and the scar is hidden. We recommend it for the treatment of mild types of cryptotia.
Growth hormone and bone health.
Bex, Marie; Bouillon, Roger
2003-01-01
Growth hormone (GH) and insulin-like growth factor-I have major effects on growth plate chondrocytes and all bone cells. Untreated childhood-onset GH deficiency (GHD) markedly impairs linear growth as well as three-dimensional bone size. Adult peak bone mass is therefore about 50% that of adults with normal height. This is mainly an effect on bone volume, whereas true bone mineral density (BMD; g/cm(3)) is virtually normal, as demonstrated in a large cohort of untreated Russian adults with childhood-onset GHD. The prevalence of fractures in these untreated childhood-onset GHD adults was, however, markedly and significantly increased in comparison with normal Russian adults. This clearly indicates that bone mass and bone size matter more than true bone density. Adequate treatment with GH can largely correct bone size and in several studies also bone mass, but it usually requires more than 5 years of continuous treatment. Adult-onset GHD decreases bone turnover and results in a mild deficit, generally between -0.5 and -1.0 z-score, in bone mineral content and BMD of the lumbar spine, radius and femoral neck. Cross-sectional surveys and the KIMS data suggest an increased incidence of fractures. GH replacement therapy increases bone turnover. The three controlled studies with follow-up periods of 18 and 24 months demonstrated a modest increase in BMD of the lumbar spine and femoral neck in male adults with adult-onset GHD, whereas no significant changes in BMD were observed in women. GHD, whether childhood- or adult-onset, impairs bone mass and strength. Appropriate substitution therapy can largely correct these deficiencies if given over a prolonged period. GH therapy for other bone disorders not associated with primary GHD needs further study but may well be beneficial because of its positive effects on the bone remodelling cycle. Copyright 2003 S. Karger AG, Basel
Immersive Earth Science: Data Visualization in Virtual Reality
NASA Astrophysics Data System (ADS)
Skolnik, S.; Ramirez-Linan, R.
2017-12-01
Utilizing next generation technology, Navteca's exploration of 3D and volumetric temporal data in Virtual Reality (VR) takes advantage of immersive user experiences where stakeholders are literally inside the data. No longer restricted by the edges of a screen, VR provides an innovative way of viewing spatially distributed 2D and 3D data that leverages a 360 field of view and positional-tracking input, allowing users to see and experience data differently. These concepts are relevant to many sectors, industries, and fields of study, as real-time collaboration in VR can enhance understanding and mission with VR visualizations that display temporally-aware 3D, meteorological, and other volumetric datasets. The ability to view data that is traditionally "difficult" to visualize, such as subsurface features or air columns, is a particularly compelling use of the technology. Various development iterations have resulted in Navteca's proof of concept that imports and renders volumetric point-cloud data in the virtual reality environment by interfacing PC-based VR hardware to a back-end server and popular GIS software. The integration of the geo-located data in VR and subsequent display of changeable basemaps, overlaid datasets, and the ability to zoom, navigate, and select specific areas show the potential for immersive VR to revolutionize the way Earth data is viewed, analyzed, and communicated.
Finite element modeling of sound transmission with perforations of tympanic membrane
Gan, Rong Z.; Cheng, Tao; Dai, Chenkai; Yang, Fan; Wood, Mark W.
2009-01-01
A three-dimensional finite element (FE) model of human ear with structures of the external ear canal, middle ear, and cochlea has been developed recently. In this paper, the FE model was used to predict the effect of tympanic membrane (TM) perforations on sound transmission through the middle ear. Two perforations were made in the posterior-inferior quadrant and inferior site of the TM in the model with areas of 1.33 and 0.82 mm2, respectively. These perforations were also created in human temporal bones with the same size and location. The vibrations of the TM (umbo) and stapes footplate were calculated from the model and measured from the temporal bones using laser Doppler vibrometers. The sound pressure in the middle ear cavity was derived from the model and measured from the bones. The results demonstrate that the TM perforations can be simulated in the FE model with geometrical visualization. The FE model provides reasonable predictions on effects of perforation size and location on middle ear transfer function. The middle ear structure-function relationship can be revealed with multi-field coupled FE analysis. PMID:19603881
Malignant otitis externa in a healthy non-diabetic patient.
Liu, Xiao-Long; Peng, Hong; Mo, Ting-Ting; Liang, Yong
2016-08-01
A healthy 60-year-old male was initially treated for external otitis, and subsequently received multiple surgeries including abscess drainage, temporal bone debridement, canaloplasty of the external auditory meatus, and fistula excision and was treated with numerous antibiotics at another hospital over a 1-year period. He was seen at our hospital on February 14, 2014 with a complaint of a non-healing wound behind the left ear and drainage of purulent fluid. He had no history of diabetes mellitus or compromised immune function. Computed tomography (CT) and magnetic resonance imaging (MRI) studies at our hospital showed osteomyelitis involving the left temporal, occipital, and sphenoid bones, the mandible, and an epidural abscess. Routine blood testing and tests of immune function were normal, and no evidence of other infectious processes was found. He was diagnosed with malignant otitis externa (MOE). Bone debridement and incision and drainage of the epidural abscess were performed, and vancomycin was administered because culture results revealed Corynebacterium jeikeium, Corynebacterium xerosis, and Enterococcus faecalis. MOE should be considered in healthy patients with external otitis who fail initial treatment.
Amatuzzi, Monica; Liberman, M Charles; Northrop, Clarinda
2011-10-01
Premature birth is a well-known risk factor for sensorineural hearing loss in general and auditory neuropathy in particular. However, relatively little is known about the underlying causes, in part because there are so few relevant histopathological studies. Here, we report on the analysis of hair cell loss patterns in 54 temporal bones from premature infants and a control group of 46 bones from full-term infants, all of whom spent time in the neonatal intensive care unit at the Hospital de Niños in San Jose, Costa Rica, between 1977 and 1993. The prevalence of significant hair cell loss was higher in the preterm group than the full-term group (41% vs. 28%, respectively). The most striking finding was the frequency of selective inner hair cell loss, an extremely rare histopathological pattern, in the preterm vs. the full-term babies (27% vs. 3%, respectively). The findings suggest that a common cause of non-genetic auditory neuropathy is selective loss of inner hair cells rather than primary damage to the cochlear nerve.
Virtual Reality Educational Tool for Human Anatomy.
Izard, Santiago González; Juanes Méndez, Juan A; Palomera, Pablo Ruisoto
2017-05-01
Virtual Reality is becoming widespread in our society within very different areas, from industry to entertainment. It has many advantages in education as well, since it allows visualizing almost any object or going anywhere in a unique way. We will be focusing on medical education, and more specifically anatomy, where its use is especially interesting because it allows studying any structure of the human body by placing the user inside each one. By allowing virtual immersion in a body structure such as the interior of the cranium, stereoscopic vision goggles make these innovative teaching technologies a powerful tool for training in all areas of health sciences. The aim of this study is to illustrate the teaching potential of applying Virtual Reality in the field of human anatomy, where it can be used as a tool for education in medicine. A Virtual Reality Software was developed as an educational tool. This technological procedure is based entirely on software which will run in stereoscopic goggles to give users the sensation of being in a virtual environment, clearly showing the different bones and foramina which make up the cranium, and accompanied by audio explanations. Throughout the results the structure of the cranium is described in detailed from both inside and out. Importance of an exhaustive morphological knowledge of cranial fossae is further discussed. Application for the design of microsurgery is also commented.
Distributed Administration of Online Learning Accounts
ERIC Educational Resources Information Center
Gamrat, Betsy
2004-01-01
Distance learning is a vital part of today's educational environment. Using complex technology, schools are able to connect instructors and students across geographic, physical, and temporal boundaries. Sophisticated software and world-wide connectivity create virtual classrooms that span the globe. These large, accessible, asynchronous,…
Real-time recording and classification of eye movements in an immersive virtual environment.
Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary
2013-10-10
Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements.
Real-time recording and classification of eye movements in an immersive virtual environment
Diaz, Gabriel; Cooper, Joseph; Kit, Dmitry; Hayhoe, Mary
2013-01-01
Despite the growing popularity of virtual reality environments, few laboratories are equipped to investigate eye movements within these environments. This primer is intended to reduce the time and effort required to incorporate eye-tracking equipment into a virtual reality environment. We discuss issues related to the initial startup and provide algorithms necessary for basic analysis. Algorithms are provided for the calculation of gaze angle within a virtual world using a monocular eye-tracker in a three-dimensional environment. In addition, we provide algorithms for the calculation of the angular distance between the gaze and a relevant virtual object and for the identification of fixations, saccades, and pursuit eye movements. Finally, we provide tools that temporally synchronize gaze data and the visual stimulus and enable real-time assembly of a video-based record of the experiment using the Quicktime MOV format, available at http://sourceforge.net/p/utdvrlibraries/. This record contains the visual stimulus, the gaze cursor, and associated numerical data and can be used for data exportation, visual inspection, and validation of calculated gaze movements. PMID:24113087
Liao, Zhipeng; Yoda, Nobuhiro; Chen, Junning; Zheng, Keke; Sasaki, Keiichi; Swain, Michael V; Li, Qing
2017-04-01
This paper aimed to develop a clinically validated bone remodeling algorithm by integrating bone's dynamic properties in a multi-stage fashion based on a four-year clinical follow-up of implant treatment. The configurational effects of fixed partial dentures (FPDs) were explored using a multi-stage remodeling rule. Three-dimensional real-time occlusal loads during maximum voluntary clenching were measured with a piezoelectric force transducer and were incorporated into a computerized tomography-based finite element mandibular model. Virtual X-ray images were generated based on simulation and statistically correlated with clinical data using linear regressions. The strain energy density-driven remodeling parameters were regulated over the time frame considered. A linear single-stage bone remodeling algorithm, with a single set of constant remodeling parameters, was found to poorly fit with clinical data through linear regression (low [Formula: see text] and R), whereas a time-dependent multi-stage algorithm better simulated the remodeling process (high [Formula: see text] and R) against the clinical results. The three-implant-supported and distally cantilevered FPDs presented noticeable and continuous bone apposition, mainly adjacent to the cervical and apical regions. The bridged and mesially cantilevered FPDs showed bone resorption or no visible bone formation in some areas. Time-dependent variation of bone remodeling parameters is recommended to better correlate remodeling simulation with clinical follow-up. The position of FPD pontics plays a critical role in mechanobiological functionality and bone remodeling. Caution should be exercised when selecting the cantilever FPD due to the risk of overloading bone resorption.
Kim, Sun Moon; Liu, Sai; Long, Jin; Montez-Rath, Maria E; Leonard, Mary B; Chertow, Glenn M
2017-11-01
The incidence of hip fracture in patients with end-stage renal disease (ESRD) is considerably higher than that in the general age- and sex-matched population. Although medical therapy for chronic kidney disease mineral bone disorder (CKD-MBD) has changed considerably over the last decade, rates of hip fracture in the entire ESRD population have not been well-characterized. Herein, we evaluated temporal trends in rates of hip fracture, in-hospital mortality, and costs of associated hospital stay in ESRD. We identified hospitalizations for hip fracture from 2003 to 2011 using the Nationwide Inpatient Sample, a representative national database inclusive of all ages and payers. We incorporated data from the United States Renal Data System and the US Census to calculate population-specific rates. Between 2003 and 2011, we identified 47,510 hip fractures in the ESRD population. The overall rate of hip fracture was 10.04/1000 person-years. The rate was 3.73/1000 person-years in patients aged less than 65 years, and 20.97/1000 person-years in patients aged 65 or older. Age- and sex-standardized rates decreased by 12.6% from 2003 (10.23/1000 person-years; 95% confidence interval [CI], 7.99/1000 to 12.47/1000) to 2011 (8.94/1000 person-years; 95% CI, 7.12/1000 to 10.75/1000). Hip fracture rates over time were virtually identical in patients aged less than 65 years; however, rates decreased by 15.3% among patients aged 65 years or older; rates declined more rapidly in older women compared with older men (p for interaction = 0.047). In-hospital mortality rate after hip fracture operation declined by 26.7% from 2003 (8.6%; 95% CI, 6.8 to 10.4) to 2011 (6.3%; 95% CI, 4.9 to 7.7). In ESRD, age- and sex-standardized hip fracture rates and associated in-hospital mortality have declined substantially over the last decade. © 2017 American Society for Bone and Mineral Research. © 2017 American Society for Bone and Mineral Research.
Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette
2010-11-01
Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.
Hau, Janice; Sarubbo, Silvio; Perchey, Guy; Crivello, Fabrice; Zago, Laure; Mellet, Emmanuel; Jobard, Gaël; Joliot, Marc; Mazoyer, Bernard M.; Tzourio-Mazoyer, Nathalie; Petit, Laurent
2016-01-01
We combined the neuroanatomists’ approach of defining a fascicle as all fibers passing through its compact stem with diffusion-weighted tractography to investigate the cortical terminations of two association tracts, the inferior fronto-occipital fasciculus (IFOF) and the uncinate fasciculus (UF), which have recently been implicated in the ventral language circuitry. The aim was to provide a detailed and quantitative description of their terminations in 60 healthy subjects and to do so to apply an anatomical stem-based virtual dissection, mimicking classical post-mortem dissection, to extract with minimal a priori the IFOF and UF from tractography datasets. In both tracts, we consistently observed more extensive termination territories than their conventional definitions, within the middle and superior frontal, superior parietal and angular gyri for the IFOF and the middle frontal gyrus and superior, middle and inferior temporal gyri beyond the temporal pole for the UF. We revealed new insights regarding the internal organization of these tracts by investigating for the first time the frequency, distribution and hemispheric asymmetry of their terminations. Interestingly, we observed a dissociation between the lateral right-lateralized and medial left-lateralized fronto-occipital branches of the IFOF. In the UF, we observed a rightward lateralization of the orbito-frontal and temporal branches. We revealed a more detailed map of the terminations of these fiber pathways that will enable greater specificity for correlating with diseased populations and other behavioral measures. The limitations of the diffusion tensor model in this study are also discussed. We conclude that anatomical stem-based virtual dissection with diffusion tractography is a fruitful method for studying the structural anatomy of the human white matter pathways. PMID:27252628
Retrograde amnesia in patients with diencephalic, temporal lobe or frontal lesions.
Kopelman, M D; Stanhope, N; Kingsley, D
1999-07-01
Patients with focal diencephalic, temporal lobe, or frontal lobe lesions were examined on various measures of remote memory. Korsakoff patients showed a severe impairment with a characteristic 'temporal gradient', whereas two patients with focal diencephalic damage (and anterograde amnesia) were virtually unimpaired on remote memory measures. Patients with frontal lobe pathology were severely impaired in the recall of autobiographical incidents and famous news events. Patients with temporal lobe pathology showed severe impairment but a relatively 'flat' temporal gradient, largely attributable to herpes encephalitis patients. From recognition and cued recall tasks, it is argued that there is an important retrieval component to the remote memory deficit across all the lesion groups. In general, the pattern of performance by the frontal lobe and temporal lobe groups was closely similar, and there was no evidence of any major access/storage difference between them. However, laterality comparisons across these groups indicated that the right temporal and frontal lobe regions may make a greater contribution to the retrieval of past episodic (incident and event) memories, whereas the left temporal region is more closely involved in the lexical-semantic labelling of remote memories.
Moore, Shannon R.; Saidel, Gerald M.; Knothe, Ulf; Knothe Tate, Melissa L.
2014-01-01
The link between mechanics and biology in the generation and the adaptation of bone has been well studied in context of skeletal development and fracture healing. Yet, the prediction of tissue genesis within - and the spatiotemporal healing of - postnatal defects, necessitates a quantitative evaluation of mechano-biological interactions using experimental and clinical parameters. To address this current gap in knowledge, this study aims to develop a mechanistic mathematical model of tissue genesis using bone morphogenetic protein (BMP) to represent of a class of factors that may coordinate bone healing. Specifically, we developed a mechanistic, mathematical model to predict the dynamics of tissue genesis by periosteal progenitor cells within a long bone defect surrounded by periosteum and stabilized via an intramedullary nail. The emergent material properties and mechanical environment associated with nascent tissue genesis influence the strain stimulus sensed by progenitor cells within the periosteum. Using a mechanical finite element model, periosteal surface strains are predicted as a function of emergent, nascent tissue properties. Strains are then input to a mechanistic mathematical model, where mechanical regulation of BMP-2 production mediates rates of cellular proliferation, differentiation and tissue production, to predict healing outcomes. A parametric approach enables the spatial and temporal prediction of endochondral tissue regeneration, assessed as areas of cartilage and mineralized bone, as functions of radial distance from the periosteum and time. Comparing model results to histological outcomes from two previous studies of periosteum-mediated bone regeneration in a common ovine model, it was shown that mechanistic models incorporating mechanical feedback successfully predict patterns (spatial) and trends (temporal) of bone tissue regeneration. The novel model framework presented here integrates a mechanistic feedback system based on the mechanosensitivity of periosteal progenitor cells, which allows for modeling and prediction of tissue regeneration on multiple length and time scales. Through combination of computational, physical and engineering science approaches, the model platform provides a means to test new hypotheses in silico and to elucidate conditions conducive to endogenous tissue genesis. Next generation models will serve to unravel intrinsic differences in bone genesis by endochondral and intramembranous mechanisms. PMID:24967742
Radiation injury to the temporal bone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guida, R.A.; Finn, D.G.; Buchalter, I.H.
1990-01-01
Osteoradionecrosis of the temporal bone is an unusual sequela of radiation therapy to the head and neck. Symptoms occur many years after the radiation is administered, and progression of the disease is insidious. Hearing loss (sensorineural, conductive, or mixed), otalgia, otorrhea, and even gross tissue extrusion herald this condition. Later, intracranial complications such as meningitis, temporal lobe or cerebellar abscess, and cranial neuropathies may occur. Reported here are five cases of this rare malady representing varying degrees of the disease process. They include a case of radiation-induced necrosis of the tympanic ring with persistent squamous debris in the external auditorymore » canal and middle ear. Another case demonstrates the progression of radiation otitis media to mastoiditis with bony sequestration. Further progression of the disease process is seen in a third case that evolved into multiple cranial neuropathies from skull base destruction. Treatment includes systemic antibiotics, local wound care, and debridement in cases of localized tissue involvement. More extensive debridement with removal of sequestrations, abscess drainage, reconstruction with vascularized tissue from regional flaps, and mastoid obliteration may be warranted for severe cases. Hyperbaric oxygen therapy has provided limited benefit.« less
Multi-temporal MRI carpal bone volumes analysis by principal axes registration
NASA Astrophysics Data System (ADS)
Ferretti, Roberta; Dellepiane, Silvana
2016-03-01
In this paper, a principal axes registration technique is presented, with the relevant application to segmented volumes. The purpose of the proposed registration is to compare multi-temporal volumes of carpal bones from Magnetic Resonance Imaging (MRI) acquisitions. Starting from the study of the second-order moment matrix, the eigenvectors are calculated to allow the rotation of volumes with respect to reference axes. Then the volumes are spatially translated to become perfectly overlapped. A quantitative evaluation of the results obtained is carried out by computing classical indices from the confusion matrix, which depict similarity measures between the volumes of the same organ as extracted from MRI acquisitions executed at different moments. Within the medical field, the way a registration can be used to compare multi-temporal images is of great interest, since it provides the physician with a tool which allows a visual monitoring of a disease evolution. The segmentation method used herein is based on the graph theory and is a robust, unsupervised and parameters independent method. Patients affected by rheumatic diseases have been considered.
Tomasi, Cristiano; Donati, Mauro; Cecchinato, Denis; Szathvary, Isacco; Corrà, Enrico; Lindhe, Jan
2018-05-01
To examine if (i) characteristics of the fresh extraction socket site influenced subsequent dimensional alterations and (ii) placement of deproteinized bovine mineral in the socket affected volumetric change during healing. Twenty seven subjects and 28 extraction sites were included. Immediately after the removal of the tooth and after 6 months of healing, stone and virtual models of the jaw were produced. A cone beam computerized tomography scan was obtained immediately after extraction and the thickness of the buccal bone wall at the extraction site was measured. Extraction sites were randomly assigned to test or control group. In the test group, extraction sockets were filled with deproteinized bone mineral and covered with a collagen membrane. In the control group, only a collagen membrane was placed. The thickness of the buccal bone wall at the extraction site influenced the amount of volume reduction that occurred. Socket grafting influenced the degree of ridge diminution only at sites where the buccal bone wall was thin (≤ 1 mm). A graft comprised of collagen-enriched deproteinized bovine bone mineral, placed to fill extraction sockets failed to influence the overall diminution of the ridge that occurred during healing. The thickness of the buccal bone wall apparently had a significant influence on volumetric alterations of the edentulous ridge following tooth extraction. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Limbert, Georges; van Lierde, Carl; Muraru, O Luiza; Walboomers, X Frank; Frank, Milan; Hansson, Stig; Middleton, John; Jaecques, Siegfried
2010-05-07
The first objective of this computational study was to assess the strain magnitude and distribution within the three-dimensional (3D) trabecular bone structure around an osseointegrated dental implant loaded axially. The second objective was to investigate the relative micromotions between the implant and the surrounding bone. The work hypothesis adopted was that these virtual measurements would be a useful indicator of bone adaptation (resorption, homeostasis, formation). In order to reach these objectives, a microCT-based finite element model of an oral implant implanted into a Berkshire pig mandible was developed along with a robust software methodology. The finite element mesh of the 3D trabecular bone architecture was generated from the segmentation of microCT scans. The implant was meshed independently from its CAD file obtained from the manufacturer. The meshes of the implant and the bone sample were registered together in an integrated software environment. A series of non-linear contact finite element (FE) analyses considering an axial load applied to the top of the implant in combination with three sets of mechanical properties for the trabecular bone tissue was devised. Complex strain distribution patterns are reported and discussed. It was found that considering the Young's modulus of the trabecular bone tissue to be 5, 10 and 15GPa resulted in maximum peri-implant bone microstrains of about 3000, 2100 and 1400. These results indicate that, for the three sets of mechanical properties considered, the magnitude of maximum strain lies within an homeostatic range known to be sufficient to maintain/form bone. The corresponding micro-motions of the implant with respect to the bone microstructure were shown to be sufficiently low to prevent fibrous tissue formation and to favour long-term osseointegration. Copyright 2010 Elsevier Ltd. All rights reserved.
Ciocca, Leonardo; Donati, Davide; Fantini, Massimiliano; Landi, Elena; Piattelli, Adriano; Iezzi, Giovanna; Tampieri, Anna; Spadari, Alessandro; Romagnoli, Noemi; Scotti, Roberto
2013-08-01
In this study, rapid CAD-CAM prototyping of pure hydroxyapatite to replace temporomandibular joint condyles was tested in sheep. Three adult animals were implanted with CAD-CAM-designed porous hydroxyapatite scaffolds as condyle substitutes. The desired scaffold shape was achieved by subtractive automated milling machining (block reduction). Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Using the same technique, fixation plates were created and applied to the scaffold pre-operatively to firmly secure the condyles to the bone and to assure primary stability of the hydroxyapatite scaffolds during masticatory function. Four months post-surgery, the sheep were sacrificed. The hydroxyapatite scaffolds were explanted, and histological specimens were prepared. Different histological tissues penetrating the scaffold macropores, the sequence of bone remodeling, new apposition of bone and/or cartilage as a consequence of the different functional anatomic role, and osseointegration at the interface between the scaffold and bone were documented. This animal model was found to be appropriate for testing CAD-CAM customization and the biomechanical properties of porous, pure hydroxyapatite scaffolds used as joint prostheses.
Computer-aided position planning of miniplates to treat facial bone defects
Wallner, Jürgen; Gall, Markus; Chen, Xiaojun; Schwenzer-Zimmerer, Katja; Reinbacher, Knut; Schmalstieg, Dieter
2017-01-01
In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon’s desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time. PMID:28817607
Computer-aided position planning of miniplates to treat facial bone defects.
Egger, Jan; Wallner, Jürgen; Gall, Markus; Chen, Xiaojun; Schwenzer-Zimmerer, Katja; Reinbacher, Knut; Schmalstieg, Dieter
2017-01-01
In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon's desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time.
Ciocca, L.; Donati, D.; Ragazzini, S.; Dozza, B.; Rossi, F.; Fantini, M.; Spadari, A.; Romagnoli, N.; Landi, E.; Tampieri, A.; Piattelli, A.; Iezzi, G.; Scotti, R.
2013-01-01
Purpose. This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Methods. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Results. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. Conclusion. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs. PMID:24073409
Ciocca, L; Donati, D; Ragazzini, S; Dozza, B; Rossi, F; Fantini, M; Spadari, A; Romagnoli, N; Landi, E; Tampieri, A; Piattelli, A; Iezzi, G; Scotti, R
2013-01-01
This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs.
A collaboration investigating endocannabinoid signalling in brain and bone.
Zimmer, Andreas
2016-05-01
Investigations into the cellular and molecular mechanisms underlying the psychoactive effects of cannabis preparations have led to the discovery of the endocannabinoid system. Interest in the central nervous system effects was initially the main focus of the research, but it soon became evident that the endocannabinoid system affects virtually every organ. The research field has therefore experienced a tremendous growth over the last decade and is now truly interdisciplinary. This short review provides a personal account of an interdisciplinary collaboration between Itai Bab from the Hebrew University of Jerusalem and the author. It describes the discovery of the endocannabinoid system in bone and the analysis of its functions. I am summarising the role of CB1 signalling as a modulator of sympathetic inhibition of bone formation. Thus, activation of CB1 receptors on sympathetic nerve terminals in bone, presumably from endocannabinoids released from apposing osteoblasts, reduces the inhibition of bone formation of sympathetic norepinephrine. CB2 receptors on osteoblasts and osteoclasts also modulate the proliferation and functions of these cells. Thus, activation of CB2 stimulates bone formation and represses bone resorption, whereas the genetic disruption of CB2 results in an osteoporosis-like phenotype. This signalling mechanism is clinically relevant, as shown by the association of polymorphisms in the CB2 receptor gene, CNR2, with bone density and osteoporosis. Finally, the review provides a summary of the recently discovered role of endocannabinoid signalling in one elongation. This review will also discuss the benefits of interdisciplinary and international collaborations.
Barber, H. O.
1965-01-01
Dizziness, whether vague or specifically rotational, is a common sequel to head injury, and is often postural. One hundred and sixty-five patients with this symptom were examined. The simple posture tests employed to detect positional nystagmus are described. This physical finding was present in one-quarter of the entire group, and in nearly one-half of cases of longitudinal fracture of temporal bone. In such cases, it is an objective finding that corresponds precisely to the patient's complaint of vertigo. Transverse fracture of temporal bone destroys the inner ear in both cochlear and vestibular parts. Longitudinal fracture is commoner and causes bleeding from the ear; inner-ear damage is usually minor. In the rare cases where persisting postural vertigo and positional nystagmus are disabling, relief of the symptom may be achieved by vestibular denervation of the affected side. PMID:14285289
Time-saving and fail-safe dissection method for vestibulocochlear organs in gross anatomy classes.
Suzuki, Ryoji; Konno, Naoaki; Ishizawa, Akimitsu; Kanatsu, Yoshinori; Funakoshi, Kodai; Akashi, Hideo; Zhou, Ming; Abe, Hiroshi
2017-09-01
Because the vestibulocochlear organs are tiny and complex, and are covered by the petrous part of the temporal bone, they are very difficult for medical students to dissect and visualize during gross anatomy classes. Here, we report a time-saving and fail-safe procedure we have devised, using a hand-held hobby router. Nine en bloc temporal bone samples from donated human cadavers were used as trial materials for devising an appropriate procedure for dissecting the vestibulocochlear organs. A hand-held hobby router was used to cut through the temporal bone. After trials, the most time-saving and fail-safe method was selected. The performance of the selected method was assessed by a survey of 242 sides of 121 cadavers during gross anatomy classes for vestibulocochlear dissection. The assessment was based on the observation ratio. The best procedure appeared to be removal of the external acoustic meatus roof and tympanic cavity roof together with removal of the internal acoustic meatus roof. The whole procedure was completed within two dissection classes, each lasting 4.5 hr. The ratio of surveillance for the chorda tympani and three semicircular canals by students was significantly improved during 2013 through 2016. In our dissection class, "removal of the external acoustic meatus roof and tympanic cavity roof together with removal of the internal acoustic meatus roof" was the best procedure for students in the limited time available. Clin. Anat. 30:703-710, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
[Applied anatomy of scala tympani inlet related to cochlear implantation].
Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping
2012-06-01
To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.
Does Otosclerosis Affect Dark and Transitional Cells in the Human Vestibular Labyrinth?
Kaya, Serdar; Paparella, Michael M; Cureoglu, Sebahattin
2017-02-01
The density of vestibular dark cells (DCs) and vestibular transitional cells (TCs) can be quantitatively decreased in human temporal bones with otosclerosis. Previous reports have shown that otosclerosis can lead to vestibular symptoms. We examined 61 human temporal bone specimens from 52 deceased donors with otosclerosis group-with and without endosteal involvement (EI), and with and without endolymphatic hydrops (EH)-versus 25 specimens from 18 age-matched controls. Using light microscopy, we evaluated the nonsensory epithelium of the lateral semicircular canal (LSC) and posterior semicircular canal (PSC) of the human vestibular labyrinth, focusing on the density of DCs and TCs. In both the LSC and the PSC, as compared with the control group, the mean density of DCs significantly decreased in the EI (+) group, in the EI (+) and EH (+) subgroup, and in the EI (+) and EH (-) subgroup (p < 0.05). In addition, we found a significant difference in the mean density of DCs between the EI (+) group and the EI (-) group in the LSC and in the PSC (p < 0.05). But we found no significant difference in the mean density of TCs in any of the otosclerosis groups or subgroups as compared with the control group (p > 0.05). We found a decrease in the density of DCs associated with EI in human temporal bone specimens with otosclerosis, regardless of the presence of EH. This decrease might cause damage in ion and water transportation, leading to vestibular symptoms.
Does Otosclerosis Affect Dark and Transitional Cells in the Human Vestibular Labyrinth?
Kaya, Serdar; Paparella, Michael M.; Cureoglu, Sebahattin
2016-01-01
Hypothesis The density of vestibular dark cells (DCs) and vestibular transitional cells (TCs) can be quantitatively decreased in human temporal bones with otosclerosis. Background Previous reports have shown that otosclerosis can lead to vestibular symptoms. Methods We examined 61 human temporal bone specimens from 52 deceased donors with otosclerosis group—with and without endosteal involvement (EI), and with and without endolymphatic hydrops (EH)—vs. 25 specimens from 18 age-matched controls. Using light microscopy, we evaluated the nonsensory epithelium of the lateral semicircular canal (LSC) and posterior semicircular canal (PSC) of the human vestibular labyrinth, focusing on the density of DCs and TCs. Results In both the LSC and the PSC, as compared with the control group, the mean density of DCs significantly decreased in the EI (+) group, in the EI (+) and EH (+) subgroup, and in the EI (+) and EH (−) subgroup (P < 0.05). In addition, we found a significant difference in the mean density of DCs between the EI (+) group and the EI (−) group in the LSC and in the PSC (P < 0.05). But we found no significant difference in the mean density of TCs in any of the otosclerosis groups or subgroups as compared with the control group (P > 0.05). Conclusion We found a decrease in the density of DCs associated with EI in human temporal bone specimens with otosclerosis, regardless of the presence of EH. This decrease might cause damage in ion and water transportation, leading to vestibular symptoms. PMID:27851656
Transmastoid approach to temporal bone cerebrospinal fluid leaks.
Oliaei, Sepehr; Mahboubi, Hossein; Djalilian, Hamid R
2012-01-01
The aim of the study was to evaluate various presentations and treatment options for spontaneous cerebrospinal fluid (CSF) leakage originating in the temporal bone. Clinical data and imaging results for 18 ears (15 patients) presenting with spontaneous CSF leakage originating in the temporal bone were reviewed. Average follow-up period was 13.5 months. The main outcome measure was presence of persistent CSF leak postoperatively. A standard postauricular mastoidectomy was performed. Fifteen patients diagnosed with spontaneous CSF leakage over an 8-year period including 3 treated for bilateral disease were included in the study. The age ranged between 33 and 83 years. Presenting symptoms included serous otitis media (44%), persistent otorrhea after tympanostomy tube placement (28%), and meningitis (28%). Preoperative diagnosis was made using imaging studies and was substantiated by observation of CSF leakage and dural herniation intraoperatively. Treatment was eustachian tube plugging (5%), mastoidectomy with fat obliteration (61%), middle fossa approach with extradural (17%), intradural repair (5%), or combined middle fossa and transmastoid (TM) approach (11%). Successful treatment was obtained in 17 of the 18 cases. The last 9 patients in the series underwent TM approach alone for repair with no treatment failures. Repair of defects in tegmen mastoideum and posterior fossa can be successfully achieved on an outpatient basis without regard to size and multitude of defects via TM approach. This approach obviates the need for a craniotomy or lumbar drain. Copyright © 2012 Elsevier Inc. All rights reserved.
Kontorinis, Georgios; Goetz, Friedrich; Lanfermann, Heinrich; Luytenski, Stefan; Giesemann, Anja M
2014-08-01
As patients with Waardenburg syndrome (WS) represent potential candidates for cochlear implantation, their inner ear anatomy is of high significance. There is an ongoing debate whether WS is related to any inner ear dysplasias. Our objective was to evaluate radiologically the inner ear anatomy in patients with WS and identify any temporal bone malformations. A retrospective case review was carried out in a tertiary, referral center. The high resolution computed tomography (HRCT) scans of the temporal bone from 20 patients (40 ears) with WS who were managed for deafness in a tertiary referral center from 1995 to 2012 were retrospectively examined. Measurements of 15 different inner ear dimensions, involving the cochlea, the vestibule, the semicircular canals and the internal auditory meatus, as well as measurements of the vestibular aqueduct, were performed independently by two neuroradiologists. Finally, we compared the results from the WS group with a control group consisting of 50 normal hearing subjects (100 ears) and with previously reported normative values. Inner ear malformations were not found in any of the patients with WS. All measured inner ear dimensions were within the normative values compiled by our study group as well as by others. Inner ear malformations are not characteristic for all types of WS; however, certain rare subtypes might be related to inner ear deformities. Normative cochleovestibular dimensions that can help in assessing the temporal bone anatomy are provided. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Montufar, E B; Casas-Luna, M; Horynová, M; Tkachenko, S; Fohlerová, Z; Diaz-de-la-Torre, S; Dvořák, K; Čelko, L; Kaiser, J
2018-04-01
In this work alpha tricalcium phosphate (α-TCP)/iron (Fe) composites were developed as a new family of biodegradable, load-bearing and cytocompatible materials. The composites with composition from pure ceramic to pure metallic samples were consolidated by pulsed electric current assisted sintering to minimise processing time and temperature while improving their mechanical performance. The mechanical strength of the composites was increased and controlled with the Fe content, passing from brittle to ductile failure. In particular, the addition of 25 vol% of Fe produced a ceramic matrix composite with elastic modulus much closer to cortical bone than that of titanium or biodegradable magnesium alloys and specific compressive strength above that of stainless steel, chromium-cobalt alloys and pure titanium, currently used in clinic for internal fracture fixation. All the composites studied exhibited higher degradation rate than their individual components, presenting values around 200 μm/year, but also their compressive strength did not show a significant reduction in the period required for bone fracture consolidation. Composites showed preferential degradation of α-TCP areas rather than β-TCP areas, suggesting that α-TCP can produce composites with higher degradation rate. The composites were cytocompatible both in indirect and direct contact with bone cells. Osteoblast-like cells attached and spread on the surface of the composites, presenting proliferation rate similar to cells on tissue culture-grade polystyrene and they showed alkaline phosphatase activity. Therefore, this new family of composites is a potential alternative to produce implants for temporal reduction of bone fractures. Biodegradable alpha-tricalcium phosphate/iron (α-TCP/Fe) composites are promising candidates for the fabrication of temporal osteosynthesis devices. Similar to biodegradable metals, these composites can avoid implant removal after bone fracture healing, particularly in young patients. In this work, α-TCP/Fe composites are studied for the first time in a wide range of compositions, showing not only higher degradation rate in vitro than pure components, but also good cytocompatibility and mechanical properties controllable with the Fe content. Ceramic matrix composites show high specific strength and low elastic modulus, thus better fulfilling the requirements for bone fractures fixation. A significant advance over previous works on the topic is the use of pulsed electric current assisted sintering together with α-TCP, convenient to improve the mechanical performance and degradation rate, respectively. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Kanczler, Janos M; Smith, Emma L; Roberts, Carol A; Oreffo, Richard O C
2012-10-01
Understanding the structural development of embryonic bone in a three dimensional framework is fundamental to developing new strategies for the recapitulation of bone tissue in latter life. We present an innovative combined approach of an organotypic embryonic femur culture model, microcomputed tomography (μCT) and immunohistochemistry to examine the development and modulation of the three dimensional structures of the developing embryonic femur. Isolated embryonic chick femurs were organotypic (air/liquid interface) cultured for 10 days in either basal, chondrogenic, or osteogenic supplemented culture conditions. The growth development and modulating effects of basal, chondrogenic, or osteogenic culture media of the embryonic chick femurs was investigated using μCT, immunohistochemistry, and histology. The growth and development of noncultured embryonic chick femur stages E10, E11, E12, E13, E15, and E17 were very closely correlated with increased morphometric indices of bone formation as determined by μCT. After 10 days in the organotpyic culture set up, the early aged femurs (E10 and E11) demonstrated a dramatic response to the chondrogenic or osteogenic culture conditions compared to the basal cultured femurs as determined by a change in μCT morphometric indices and modified expression of chondrogenic and osteogenic markers. Although the later aged femurs (E12 and E13) increased in size and structure after 10 days organotpypic culture, the effects of the osteogenic and chondrogenic organotypic cultures on these femurs were not significantly altered compared to basal conditions. We have demonstrated that the embryonic chick femur organotpyic culture model combined with the μCT and immunohistochemical analysis can provide an integral methodology for investigating the modulation of bone development in an ex vivo culture setting. Hence, these interdisciplinary techniques of μCT and whole organ bone cultures will enable us to delineate some of the temporal, structural developmental paradigms and modulation of bone tissue formation to underpin innovative skeletal regenerative technology for clinical therapeutic strategies in musculoskeletal trauma and diseases.
Software Architecture for a Virtual Environment for Nano Scale Assembly (VENSA).
Lee, Yong-Gu; Lyons, Kevin W; Feng, Shaw C
2004-01-01
A Virtual Environment (VE) uses multiple computer-generated media to let a user experience situations that are temporally and spatially prohibiting. The information flow between the user and the VE is bidirectional and the user can influence the environment. The software development of a VE requires orchestrating multiple peripherals and computers in a synchronized way in real time. Although a multitude of useful software components for VEs exists, many of these are packaged within a complex framework and can not be used separately. In this paper, an architecture is presented which is designed to let multiple frameworks work together while being shielded from the application program. This architecture, which is called the Virtual Environment for Nano Scale Assembly (VENSA), has been constructed for interfacing with an optical tweezers instrument for nanotechnology development. However, this approach can be generalized for most virtual environments. Through the use of VENSA, the programmer can rely on existing solutions and concentrate more on the application software design.
Software Architecture for a Virtual Environment for Nano Scale Assembly (VENSA)
Lee, Yong-Gu; Lyons, Kevin W.; Feng, Shaw C.
2004-01-01
A Virtual Environment (VE) uses multiple computer-generated media to let a user experience situations that are temporally and spatially prohibiting. The information flow between the user and the VE is bidirectional and the user can influence the environment. The software development of a VE requires orchestrating multiple peripherals and computers in a synchronized way in real time. Although a multitude of useful software components for VEs exists, many of these are packaged within a complex framework and can not be used separately. In this paper, an architecture is presented which is designed to let multiple frameworks work together while being shielded from the application program. This architecture, which is called the Virtual Environment for Nano Scale Assembly (VENSA), has been constructed for interfacing with an optical tweezers instrument for nanotechnology development. However, this approach can be generalized for most virtual environments. Through the use of VENSA, the programmer can rely on existing solutions and concentrate more on the application software design. PMID:27366610
Tendon entheses of the human masticatory muscles.
Hems, T; Tillmann, B
2000-09-01
Tendons attach to the limb skeleton via chondral-apophysary or periosteal-diaphysary entheses. It was the aim of the present study to investigate the tendon entheses of the temporal, the masseter, as well as the medial and lateral pterygoid muscles, considering the biomechanics and the mode of osteogenesis at the attachment sites. The origin and insertion zones of the four masticatory muscles were studied histologically and by polarization light microscopy in six halves of human heads. Contrary to the limb skeleton no causal relationship between the histological structure of the tendon entheses and the osteogenic mode of the bone areas involved was observed in the masticatory muscles that were studied. Based on the histological findings, a purely structural classification of the tendon attachments irrespective of the osteogenesis is therefore proposed that is applicable to the entire skeleton. It is possible to distinguish between tendon entheses inserting into periosteum, into bone or into fibrocartilage. Tendon attachments with periosteal insertion are found at the temporal plane, the retromolar triangle, zygomatic arch, lateral pterygoid plate, in the caudal zone of the pterygoid fovea of the neck of mandible as well as major portions of the ramus and angle of the mandible. The attachment zones in which collagen fibrils of tendons insert into the bone via the periosteum correspond in their structure to plane periosteal-diaphysary insertions into the diaphyses of long bones. Attachment zones to the bone are present at the inferior temporal line, the base of the coronoid process, the caudal surface of the zygomatic arch, the cranial zones of the pterygoid fovea of the neck of the mandible as well as at circumscribed areas of the ramus and angle of the mandible. In these zones the collagen fibers of the tendon insert immediately into the bone without any mediation of other tissues. The entheses resemble those of circumscribed periosteal-diaphysary attachments to long bones. Fibrocartilaginous entheses occur at the coronoid process, the cranialmost portions of the pterygoid fovea of the neck of the mandible as well as in circumscribed areas of the medial and lateral facets of the angle of the mandible. The structures of these attachment sites are comparable to chondral-apophysary tendon attachments. As for masticatory muscles, the described forms of tendon entheses occur at the same time in the majority of the attachment sites. From the structure of the three types of tendon entheses it is possible to conclude that they fulfill a biomechanical function similar to that of the limb skeleton, namely adapting the different elasticity moduli of bone and tendon tissues. From a technical perspective they can be considered to act as an "angle and stretching brake".
Testing the Construct Validity of a Virtual Reality Hip Arthroscopy Simulator.
Khanduja, Vikas; Lawrence, John E; Audenaert, Emmanuel
2017-03-01
To test the construct validity of the hip diagnostics module of a virtual reality hip arthroscopy simulator. Nineteen orthopaedic surgeons performed a simulated arthroscopic examination of a healthy hip joint using a 70° arthroscope in the supine position. Surgeons were categorized as either expert (those who had performed 250 hip arthroscopies or more) or novice (those who had performed fewer than this). Twenty-one specific targets were visualized within the central and peripheral compartments; 9 via the anterior portal, 9 via the anterolateral portal, and 3 via the posterolateral portal. This was immediately followed by a task testing basic probe examination of the joint in which a series of 8 targets were probed via the anterolateral portal. During the tasks, the surgeon's performance was evaluated by the simulator using a set of predefined metrics including task duration, number of soft tissue and bone collisions, and distance travelled by instruments. No repeat attempts at the tasks were permitted. Construct validity was then evaluated by comparing novice and expert group performance metrics over the 2 tasks using the Mann-Whitney test, with a P value of less than .05 considered significant. On the visualization task, the expert group outperformed the novice group on time taken (P = .0003), number of collisions with soft tissue (P = .001), number of collisions with bone (P = .002), and distance travelled by the arthroscope (P = .02). On the probe examination, the 2 groups differed only in the time taken to complete the task (P = .025) with no significant difference in other metrics. Increased experience in hip arthroscopy was reflected by significantly better performance on the virtual reality simulator across 2 tasks, supporting its construct validity. This study validates a virtual reality hip arthroscopy simulator and supports its potential for developing basic arthroscopic skills. Level III. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.
Bone Metabolism on ISS Missions
NASA Technical Reports Server (NTRS)
Smith, S. M.; Heer, M. A.; Shackelford, L. C.; Zwart, S. R.
2014-01-01
Spaceflight-induced bone loss is associated with increased bone resorption (1, 2), and either unchanged or decreased rates of bone formation. Resistive exercise had been proposed as a countermeasure, and data from bed rest supported this concept (3). An interim resistive exercise device (iRED) was flown for early ISS crews. Unfortunately, the iRED provided no greater bone protection than on missions where only aerobic and muscular endurance exercises were available (4, 5). In 2008, the Advanced Resistive Exercise Device (ARED), a more robust device with much greater resistance capability, (6, 7) was launched to the ISS. Astronauts who had access to ARED, coupled with adequate energy intake and vitamin D status, returned from ISS missions with bone mineral densities virtually unchanged from preflight (7). Bone biochemical markers showed that while the resistive exercise and adequate energy consumption did not mitigate the increased bone resorption, bone formation was increased (7, 8). The typical drop in circulating parathyroid hormone did not occur in ARED crewmembers. In 2014, an updated look at the densitometry data was published. This study confirmed the initial findings with a much larger set of data. In 42 astronauts (33 male, 9 female), the bone mineral density response to flight was the same for men and women (9), and those with access to the ARED did not have the typical decrease in bone mineral density that was observed in early ISS crewmembers with access to the iRED (Figure 1) (7). Biochemical markers of bone formation and resorption responded similarly in men and women. These data are encouraging, and represent the first in-flight evidence in the history of human space flight that diet and exercise can maintain bone mineral density on long-duration missions. However, the maintenance of bone mineral density through bone remodeling, that is, increases in both resorption and formation, may yield a bone with strength characteristics different from those that existed before space flight. Studies to assess bone strength after flight are underway at NASA, to better understand the results of bone remodeling. Studies are also underway to evaluate optimized exercise protocols and nutritional countermeasures. Regardless, there is clear evidence of progress being made to protect bone during spaceflight.
2014-02-28
sockets.6 The commercially available INFUSE system (Medtronic Spinal and Biologics, Memphis, TN), compris- ing an absorbable collagen sponge plus...a collagen sponge carrier) by Medtronics27 for bone healing in rabbits. Even the 25mg rhBMP-2 dose used showed significantly greater re- generated...visualization No 3D morphological analysis for small-animal modelsCan be repeated over course of healing for temporal trends Potential risk of X-ray
Tuberculous otitis media: a clinical and radiologic analysis of 52 patients.
Cho, Yang-Sun; Lee, Hyun-Seok; Kim, Sang-Woo; Chung, Kyu-Hwan; Lee, Dong-Kyung; Koh, Won-Jung; Kim, Myung-Gu
2006-06-01
This retrospective study reports on the clinical and radiologic features and the treatment outcomes of patients with tuberculous otitis media (TOM). We reviewed the medical records of 52 patients (53 ears) with TOM between 1993 and 2005 and analyzed temporal bone computed tomography scans of 23 patients. The diagnosis of TOM was made if a specimen of the middle ear revealed the presence of acid fast bacilli (AFB), grew Mycobacterium tuberculosis (M. Tb) on a culture, revealed characteristic histology, and/or was positive for polymerase chain reaction (PCR) for M. Tb. The highest incidence of the disease was observed among patients in their 30s. The main symptom was otorrhea, and the duration of symptoms was shorter than with nonspecific chronic otitis media. Most patients demonstrated a moderate to severe hearing loss. Five patients (9.6%) demonstrated a peripheral-type facial palsy. Temporal bone CT scans demonstrated relatively well-pneumatized mastoids and occupation by soft tissue of the entire tympanum and mastoid air cells. Six patients demonstrated bone destruction that involved the cortex of the mastoid bone. In most patients, antituberculous medication was effective treatment. The patients who underwent chemotherapy after surgery achieved more rapid healing of the ear and more frequent closure of the tympanic membrane than those who did not receive surgery. Clinicians should have a high index of suspicion and be aware of the clinical and radiologic characteristics of TOM.
Matroskin, A G; Rakhmanova, I V; Dreval', A A; Kislyakov, A N; Vladimirov, A I
The objective of the present study was to elucidate the anatomical features of the structure of the middle ear and eustachian tube in the breast-fed infants of different gestational age that may be responsible for the formation of exudates (fluids). We have examined 150 temporal bones obtained from the children's cadavers that were allocated to three groups as follows: 50 temporal bones obtained at weeks 26-30 weeks of gestation (group 1), 44 bones 31-36 weeks of gestation (group 2), and 37-40 weeks of gestation (full-term babies, group 3),The analysis of the data obtained on an individual bases revealed either increase or decreases in the selected characteristics of the eustachian tube in comparison with the respective average values as well as the well apparent predominance of a single change or a combination of alteration of several parameters in one case in 26-30 weeks and 31-36 weeks groups. No significant changes were found in group 1. It is concluded that the presence of a single change or a combination of two or three abnormal changes in the parameters of the bone structures of the eustachian tube can affect the development of the secretory process in the middle ear especially in the children born after 36 weeks of pregnancy.
Altieri, Roberto; Sameshima, Tetsuro; Pacca, Paolo; Crobeddu, Emanuela; Garbossa, Diego; Ducati, Alessandro; Zenga, Francesco
2017-04-01
Petroclival meningiomas are a challenge for neurosurgeons due to the complex anatomy of the region that is rich of vessels and nerves. A perfect and detailed knowledge of the anatomy is very demanding in neurosurgery, especially in skull base surgery. The authors describe the microsurgical anatomy to perform an anterior petrosectomy based on their anatomical and surgical experience and perform a literature review. The temporal bone is the most complex and fascinating bone of skull base. The apex is located in the angle between the greater wing of the sphenoid and the occipital bone. Removing the petrous apex exposes the clivus. The approach directed through the temporal bone in this anatomical area is referred to as an anterior petrosectomy. The area that must be drilled is the rhomboid fossa that is defined by the Kawase, premeatal, and postmeatal triangles. In Division of Neurosurgery - University of Turin, 130 patients, from August 2013 to September 2015, underwent surgical resection of intracranial meningiomas. In this group, we have operated 7 PCMs and 5 of these were approached performing an anterior petrosectomy with good results. In our conclusions, we feel that this surgery require an advanced knowledge of human anatomy and a specialized training in interpretation of radiological and microsurgical anatomy both in the dissection lab and in the operating room.
McCoul, Edward D; Hanson, Matthew B
2011-12-01
We conducted a retrospective study to compare the clinical characteristics of external auditory canal cholesteatoma (EACC) with those of a similar entity, keratosis obturans (KO). We also sought to identify those aspects of each disease that may lead to complications. We identified 6 patients in each group. Imaging studies were reviewed for evidence of bony erosion and the proximity of disease to vital structures. All 6 patients in the EACC group had their diagnosis confirmed by computed tomography (CT), which demonstrated widening of the bony external auditory canal; 4 of these patients had critical erosion of bone adjacent to the facial nerve. Of the 6 patients with KO, only 2 had undergone CT, and neither exhibited any significant bony erosion or expansion; 1 of them developed osteomyelitis of the temporal bone and adjacent temporomandibular joint. Another patient manifested KO as part of a dermatophytid reaction. The essential component of treatment in all cases of EACC was microscopic debridement of the ear canal. We conclude that EACC may produce significant erosion of bone with exposure of vital structures, including the facial nerve. Because of the clinical similarity of EACC to KO, misdiagnosis is possible. Temporal bone imaging should be obtained prior to attempts at debridement of suspected EACC. Increased awareness of these uncommon conditions is warranted to prompt appropriate investigation and prevent iatrogenic complications such as facial nerve injury.
Observations on the bony bridging of the jugular foramen in man.
Dodo, Y
1986-02-01
The anatomical nature and pattern of incidence of bony bridging of the jugular foramen was investigated using 64 fetal crania aged nine months to term and 222 adult crania of Japanese. In addition, the region of the jugular foramen of an adult cadaver was carefully dissected in order to clarify the relationship between the cranial nerves passing through the jugular foramen and the intrajugular processes of the jugular foramen. The general conclusions concerning the anatomical nature of the bony bridging of the jugular foramen were as follows. (1) The intrajugular process of the temporal bone is situated posterior to the triangular depression (as described in Gray's Anatomy) of the petrous part. (2) The bony bridging of the jugular foramen is established by the contact of the intrajugular process of the temporal bone with the bony process of the occipital bone projecting either from just above the hypoglossal canal (Type I) or from posterior to the hypoglossal canal (Type III). (3) If both the processes of the occipital bone reach the intrajugular process of the temporal bone simultaneously, the jugular foramen is divided into three compartments. (4) In the case of Type I bridging, the anteromedial compartment transmits the glossopharyngeal nerve, while the posterolateral compartment gives passage to the vagus nerve, the accessory nerve and the internal jugular vein. (5) In the case of Type II bridging, the anteromedial compartment contains the glossopharyngeal, vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. (6) When tripartite division of the jugular foramen occurs, the anteromedial compartment transmits the glossopharyngeal nerve, the middle compartment contains the vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. Concerning the pattern of incidence of jugular foramen bridging in the Japanese fetal and adult cranial series, this is similar to that of the bony bridging of the hypoglossal canal. The fact that almost all the cases of bridging of the jugular foramen are already established by the end of fetal development must serve as a strong indication that this trait can be used effectively for anthropological population studies.
Feasibility of Clinician-Facilitated Three-Dimensional Printing of Synthetic Cranioplasty Flaps.
Panesar, Sandip S; Belo, Joao Tiago A; D'Souza, Rhett N
2018-05-01
Integration of three-dimensional (3D) printing and stereolithography into clinical practice is in its nascence, and concepts may be esoteric to the practicing neurosurgeon. Currently, creation of 3D printed implants involves recruitment of offsite third parties. We explored a range of 3D scanning and stereolithographic techniques to create patient-specific synthetic implants using an onsite, clinician-facilitated approach. We simulated bilateral craniectomies in a single cadaveric specimen. We devised 3 methods of creating stereolithographically viable virtual models from removed bone. First, we used preoperative and postoperative computed tomography scanner-derived bony window models from which the flap was extracted. Second, we used an entry-level 3D light scanner to scan and render models of the individual bone pieces. Third, we used an arm-mounted, 3D laser scanner to create virtual models using a real-time approach. Flaps were printed from the computed tomography scanner and laser scanner models only in a ultraviolet-cured polymer. The light scanner did not produce suitable virtual models for printing. The computed tomography scanner-derived models required extensive postfabrication modification to fit the existing defects. The laser scanner models assumed good fit within the defects without any modification. The methods presented varying levels of complexity in acquisition and model rendering. Each technique required hardware at varying in price points from $0 to approximately $100,000. The laser scanner models produced the best quality parts, which had near-perfect fit with the original defects. Potential neurosurgical applications of this technology are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
Archavlis, Eleftherios; Schwandt, Eike; Kosterhon, Michael; Gutenberg, Angelika; Ulrich, Peter; Nimer, Amr; Giese, Alf; Kantelhardt, Sven Rainer
2016-07-01
The main difficulties of transpedicular corpectomies are lack of space for vertebral body replacement in the neighborhood of critical structures, the necessity for sacrifice of nerve roots in the thoracic spine. and the extent of hemorrhage due to venous epidural bleeding. We present a modified technique of transpedicular corpectomy by using an endoscopic-assisted microsurgical technique performed through a single posterior approach. A 3-dimensional (3D) preoperative reconstruction could be helpful in the planning for this complex anatomic region. Surface and volume 3D reconstruction were performed by Amira or the Dextroscope. The clinical experience of this study includes 7 cases, 2 with an unstable burst fracture and 5 with metastatic destructive vertebral body disease, all with significant retropulsion and obstruction of the spinal canal. We performed a comparison with a conventional cohort of transpedicular thoracic corpectomies. Qualitative parameters of the 3D virtual reality planning included degree of bone removal and distance from critical structures such as myelon and implant diameter. Parameters were met in each case, with demonstration of optimal positioning of the implant without neurological complications. In all patients, the endoscope was a significant help in identifying the origins of active bleeding, residual tumor, extent of bone removal, facilitating cage insertion in a minimally invasive way, and helping to avoid root sacrifice on both sides. Microsurgical endoscopic-assisted transpedicular corpectomy may prove valuable in enhancing the safety of corpectomy in destructive vertebral body disease. The 3D virtual anatomic model greatly facilitated the preoperative planning. Copyright © 2016 Elsevier Inc. All rights reserved.
Virtually fabricated guide for placement of the C-tube miniplate.
Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald
2014-05-01
This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.
Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F
2013-09-01
The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.
Bone tissue engineering: a review in bone biomimetics and drug delivery strategies.
Porter, Joshua R; Ruckh, Timothy T; Popat, Ketul C
2009-01-01
Critical-sized defects in bone, whether induced by primary tumor resection, trauma, or selective surgery have in many cases presented insurmountable challenges to the current gold standard treatment for bone repair. The primary purpose of a tissue-engineered scaffold is to use engineering principles to incite and promote the natural healing process of bone which does not occur in critical-sized defects. A synthetic bone scaffold must be biocompatible, biodegradable to allow native tissue integration, and mimic the multidimensional hierarchical structure of native bone. In addition to being physically and chemically biomimetic, an ideal scaffold is capable of eluting bioactive molecules (e.g., BMPs, TGF-betas, etc., to accelerate extracellular matrix production and tissue integration) or drugs (e.g., antibiotics, cisplatin, etc., to prevent undesired biological response such as sepsis or cancer recurrence) in a temporally and spatially controlled manner. Various biomaterials including ceramics, metals, polymers, and composites have been investigated for their potential as bone scaffold materials. However, due to their tunable physiochemical properties, biocompatibility, and controllable biodegradability, polymers have emerged as the principal material in bone tissue engineering. This article briefly reviews the physiological and anatomical characteristics of native bone, describes key technologies in mimicking the physical and chemical environment of bone using synthetic materials, and provides an overview of local drug delivery as it pertains to bone tissue engineering is included. (c) 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009.
Abshagen, K; Schrodi, I; Gerber, T; Vollmar, B
2009-11-01
One of the major challenges in the application of bone substitutes is adequate vascularization and biocompatibility of the implant. Thus, the temporal course of neovascularization and the microvascular inflammatory response of implants of NanoBone (fully synthetic nanocrystalline bone grafting material) were studied in vivo by using the mouse dorsal skinfold chamber model. Angiogenesis, microhemodynamics, and leukocyte-endothelial cell interaction were analyzed repetitively after implantation in the center and in the border zone of the implant up to 15 days. Both NanoBone granules and plates exhibited high biocompatibility comparable to that of cancellous bone, as indicated by a lack of venular leukocyte activation after implantation. In both synthetic NanoBone groups, signs of angiogenesis could be observed even at day 5 after implantation, whereas granules showed higher functional vessel density compared with NanoBone plates. The angiogenic response of the cancellous bone was markedly accelerated in the center of the implant tissue. Histologically, implant tissue showed an ingrowth of vascularized fibrous tissue into the material combined with an increased number of foreign-body giant cells. In conclusion, NanoBone, particularly in granular form, showed high biocompatibility and high angiogenic response, thus improving the healing of bone defects. Our results underline that, beside the composition and nanostructure, the macrostructure is also of importance for the incorporation of the biomaterial by the host tissue. (c) 2008 Wiley Periodicals, Inc.
NF-κB as a Therapeutic Target in Inflammatory-Associated Bone Diseases.
Lin, T-H; Pajarinen, J; Lu, L; Nabeshima, A; Cordova, L A; Yao, Z; Goodman, S B
Inflammation is a defensive mechanism for pathogen clearance and maintaining tissue homeostasis. In the skeletal system, inflammation is closely associated with many bone disorders including fractures, nonunions, periprosthetic osteolysis (bone loss around orthopedic implants), and osteoporosis. Acute inflammation is a critical step for proper bone-healing and bone-remodeling processes. On the other hand, chronic inflammation with excessive proinflammatory cytokines disrupts the balance of skeletal homeostasis involving osteoblastic (bone formation) and osteoclastic (bone resorption) activities. NF-κB is a transcriptional factor that regulates the inflammatory response and bone-remodeling processes in both bone-forming and bone-resorption cells. In vitro and in vivo evidences suggest that NF-κB is an important potential therapeutic target for inflammation-associated bone disorders by modulating inflammation and bone-remodeling process simultaneously. The challenges of NF-κB-targeting therapy in bone disorders include: (1) the complexity of canonical and noncanonical NF-κB pathways; (2) the fundamental roles of NF-κB-mediated signaling for bone regeneration at earlier phases of tissue damage and acute inflammation; and (3) the potential toxic effects on nontargeted cells such as lymphocytes. Recent developments of novel inhibitors with differential approaches to modulate NF-κB activity, and the controlled release (local) or bone-targeting drug delivery (systemic) strategies, have largely increased the translational application of NF-κB therapy in bone disorders. Taken together, temporal modulation of NF-κB pathways with the combination of recent advanced bone-targeting drug delivery techniques is a highly translational strategy to reestablish homeostasis in the skeletal system. © 2017 Elsevier Inc. All rights reserved.
NF-κB as a Therapeutic Target in Inflammatory-Associated Bone Diseases
Lin, T.-h.; Pajarinen, J.; Lu, L.; Nabeshima, A.; Cordova, L.A.; Yao, Z.; Goodman, S.B.
2017-01-01
Inflammation is a defensive mechanism for pathogen clearance and maintaining tissue homeostasis. In the skeletal system, inflammation is closely associated with many bone disorders including fractures, nonunions, periprosthetic osteolysis (bone loss around orthopedic implants), and osteoporosis. Acute inflammation is a critical step for proper bone-healing and bone-remodeling processes. On the other hand, chronic inflammation with excessive proinflammatory cytokines disrupts the balance of skeletal homeostasis involving osteoblastic (bone formation) and osteoclastic (bone resorption) activities. NF-κB is a transcriptional factor that regulates the inflammatory response and bone-remodeling processes in both bone-forming and bone-resorption cells. In vitro and in vivo evidences suggest that NF-κB is an important potential therapeutic target for inflammation-associated bone disorders by modulating inflammation and bone-remodeling process simultaneously. The challenges of NF-κB-targeting therapy in bone disorders include: (1) the complexity of canonical and noncanonical NF-κB pathways; (2) the fundamental roles of NF-κB-mediated signaling for bone regeneration at earlier phases of tissue damage and acute inflammation; and (3) the potential toxic effects on nontargeted cells such as lymphocytes. Recent developments of novel inhibitors with differential approaches to modulate NF-κB activity, and the controlled release (local) or bone-targeting drug delivery (systemic) strategies, have largely increased the translational application of NF-κB therapy in bone disorders. Taken together, temporal modulation of NF-κB pathways with the combination of recent advanced bone-targeting drug delivery techniques is a highly translational strategy to reestablish homeostasis in the skeletal system. PMID:28215222
Ablation of the Sam68 RNA Binding Protein Protects Mice from Age-Related Bone Loss
Richard, Stéphane; Torabi, Nazi; Franco, Gladys Valverde; Tremblay, Guy A; Chen, Taiping; Vogel, Gillian; Morel, Mélanie; Cléroux, Patrick; Forget-Richard, Alexandre; Komarova, Svetlana; Tremblay, Michel L; Li, Wei; Li, Ailian; Gao, Yun Jing; Henderson, Janet E
2005-01-01
The Src substrate associated in mitosis of 68 kDa (Sam68) is a KH-type RNA binding protein that has been shown to regulate several aspects of RNA metabolism; however, its physiologic role has remained elusive. Herein we report the generation of Sam68-null mice by homologous recombination. Aged Sam68−/− mice preserved their bone mass, in sharp contrast with 12-month-old wild-type littermates in which bone mass was decreased up to approximately 75%. In fact, the bone volume of the 12-month-old Sam68−/− mice was virtually indistinguishable from that of 4-month-old wild-type or Sam68−/− mice. Sam68−/− bone marrow stromal cells had a differentiation advantage for the osteogenic pathway. Moreover, the knockdown of Sam68 using short hairpin RNA in the embryonic mesenchymal multipotential progenitor C3H10T1/2 cells resulted in more pronounced expression of the mature osteoblast marker osteocalcin when differentiation was induced with bone morphogenetic protein-2. Cultures of mouse embryo fibroblasts generated from Sam68+/+ and Sam68−/− littermates were induced to differentiate into adipocytes with culture medium containing pioglitazone and the Sam68−/− mouse embryo fibroblasts shown to have impaired adipocyte differentiation. Furthermore, in vivo it was shown that sections of bone from 12-month-old Sam68−/− mice had few marrow adipocytes compared with their age-matched wild-type littermate controls, which exhibited fatty bone marrow. Our findings identify endogenous Sam68 as a positive regulator of adipocyte differentiation and a negative regulator of osteoblast differentiation, which is consistent with Sam68 being a modulator of bone marrow mesenchymal cell differentiation, and hence bone metabolism, in aged mice. PMID:16362077
Polley, John W; Figueroa, Alvaro A
2013-05-01
To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Construction of a 3-D anatomical model for teaching temporal lobectomy.
de Ribaupierre, Sandrine; Wilson, Timothy D
2012-06-01
Although we live and work in 3 dimensional space, most of the anatomical teaching during medical school is done on 2-D (books, TV and computer screens, etc). 3-D spatial abilities are essential for a surgeon but teaching spatial skills in a non-threatening and safe educational environment is a much more difficult pedagogical task. Currently, initial anatomical knowledge formation or specific surgical anatomy techniques, are taught either in the OR itself, or in cadaveric labs; which means that the trainee has only limited exposure. 3-D computer models incorporated into virtual learning environments may provide an intermediate and key step in a blended learning approach for spatially challenging anatomical knowledge formation. Specific anatomical structures and their spatial orientation can be further clinically contextualized through demonstrations of surgical procedures in the 3-D digital environments. Recordings of digital models enable learner reviews, taking as much time as they want, stopping the demonstration, and/or exploring the model to understand the anatomical relation of each structure. We present here how a temporal lobectomy virtual model has been developed to aid residents and fellows conceptualization of the anatomical relationships between different cerebral structures during that procedure. We suggest in comparison to cadaveric dissection, such virtual models represent a cost effective pedagogical methodology providing excellent support for anatomical learning and surgical technique training. Copyright © 2012 Elsevier Ltd. All rights reserved.
Virtual mission stage I: Implications of a spaceborne surface water mission
NASA Astrophysics Data System (ADS)
Clark, E. A.; Alsdorf, D. E.; Bates, P.; Wilson, M. D.; Lettenmaier, D. P.
2004-12-01
The interannual and interseasonal variability of the land surface water cycle depend on the distribution of surface water in lakes, wetlands, reservoirs, and river systems; however, measurements of hydrologic variables are sparsely distributed, even in industrialized nations. Moreover, the spatial extent and storage variations of lakes, reservoirs, and wetlands are poorly known. We are developing a virtual mission to demonstrate the feasibility of observing surface water extent and variations from a spaceborne platform. In the first stage of the virtual mission, on which we report here, surface water area and fluxes are emulated using simulation modeling over three continental scale river basins, including the Ohio River, the Amazon River and an Arctic river. The Variable Infiltration Capacity (VIC) macroscale hydrologic model is used to simulate evapotranspiration, soil moisture, snow accumulation and ablation, and runoff and streamflow over each basin at one-eighth degree resolution. The runoff from this model is routed using a linear transfer model to provide input to a much more detailed flow hydraulics model. The flow hydraulics model then routes runoff through various channel and floodplain morphologies at a 250 m spatial and 20 second temporal resolution over a 100 km by 500 km domain. This information is used to evaluate trade-offs between spatial and temporal resolutions of a hypothetical high resolution spaceborne altimeter by synthetically sampling the resultant model-predicted water surface elevations.
Zhang, Lei; Shen, Shunyao; Yu, Hongbo; Shen, Steve Guofang; Wang, Xudong
2015-07-01
The aim of this study was to investigate the use of computer-aided design and computer-aided manufacturing hydroxyapatite (HA)/epoxide acrylate maleic (EAM) compound construction artificial implants for craniomaxillofacial bone defects. Computed tomography, computer-aided design/computer-aided manufacturing and three-dimensional reconstruction, as well as rapid prototyping were performed in 12 patients between 2008 and 2013. The customized HA/EAM compound artificial implants were manufactured through selective laser sintering using a rapid prototyping machine into the exact geometric shapes of the defect. The HA/EAM compound artificial implants were then implanted during surgical reconstruction. Color-coded superimpositions demonstrated the discrepancy between the virtual plan and achieved results using Geomagic Studio. As a result, the HA/EAM compound artificial bone implants were perfectly matched with the facial areas that needed reconstruction. The postoperative aesthetic and functional results were satisfactory. The color-coded superimpositions demonstrated good consistency between the virtual plan and achieved results. The three-dimensional maximum deviation is 2.12 ± 0.65 mm and the three-dimensional mean deviation is 0.27 ± 0.07 mm. No facial nerve weakness or pain was observed at the follow-up examinations. Only 1 implant had to be removed 2 months after the surgery owing to severe local infection. No other complication was noted during the follow-up period. In conclusion, computer-aided, individually fabricated HA/EAM compound construction artificial implant was a good craniomaxillofacial surgical technique that yielded improved aesthetic results and functional recovery after reconstruction.
Kaufman, C L; Li, H; Ildstad, S T
1997-03-01
Complete replacement of the immune system via allogeneic bone marrow transplantation is sufficient to prevent diabetes in the nonobese diabetic (NOD) mouse model. In the present study we examined whether mixed allogeneic reconstitution would be sufficient to interrupt the autoimmune process with respect to occurrence of overt diabetes, as well as preexisting autoimmune insulitis. NOD mice were lethally irradiated and reconstituted with a mixture of NOD and B10.BR marrow. A relative resistance to allogeneic bone marrow engraftment was noted in NOD recipients of the mixed bone marrow inoculum, compared with disease-resistant controls. Moreover, unlike disease-resistant controls, all animals that initially repopulated as mixed donor/host chimeras became predominantly allogeneic by 4 mo, suggesting a competitive advantage for long term engraftment for disease-resistant marrow. All but one mouse in the group that engrafted with allogeneic marrow remained free of diabetes for the entire follow-up period (n = 22). Moreover, in all animals examined, virtually all islets were free of insulitis. In contrast, 74% of NOD mice that received similar conditioning and failed to engraft with donor marrow developed acute diabetes and intra-islet insulitis was present in all animals examined. These data suggest that NOD mice exhibit a relative resistance to engraftment compared with disease-resistant recipients. Conversely, animals that initially repopulated as a mixture of syngeneic and donor marrow become converted to virtually all donor by 4 mo. These data provide additional support that a defective stem cell is responsible for autoimmune diabetes in this experimental model.
Autonomous bone reposition around anatomical landmark for robot-assisted orthognathic surgery.
Woo, Sang-Yoon; Lee, Sang-Jeong; Yoo, Ji-Yong; Han, Jung-Joon; Hwang, Soon-Jung; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Yi, Won-Jin
2017-12-01
The purpose of this study was to develop a new method for enabling a robot to assist a surgeon in repositioning a bone segment to accurately transfer a preoperative virtual plan into the intraoperative phase in orthognathic surgery. We developed a robot system consisting of an arm with six degrees of freedom, a robot motion-controller, and a PC. An end-effector at the end of the robot arm transferred the movements of the robot arm to the patient's jawbone. The registration between the robot and CT image spaces was performed completely preoperatively, and the intraoperative registration could be finished using only position changes of the tracking tools at the robot end-effector and the patient's splint. The phantom's maxillomandibular complex (MMC) connected to the robot's end-effector was repositioned autonomously by the robot movements around an anatomical landmark of interest based on the tool center point (TCP) principle. The robot repositioned the MMC around the TCP of the incisor of the maxilla and the pogonion of the mandible following plans for real orthognathic patients. The accuracy of the robot's repositioning increased when an anatomical landmark for the TCP was close to the registration fiducials. In spite of this influence, we could increase the repositioning accuracy at the landmark by using the landmark itself as the TCP. With its ability to incorporate virtual planning using a CT image and autonomously execute the plan around an anatomical landmark of interest, the robot could help surgeons reposition bones more accurately and dexterously. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
The Estuary Data Mapper (EDM) is a free, interactive virtual gateway to coastal data aimed to promote research and aid in environmental management. The graphical user interface allows users to custom select and subset data based on their spatial and temporal interests giving them...
Method and Apparatus for Virtual Interactive Medical Imaging by Multiple Remotely-Located Users
NASA Technical Reports Server (NTRS)
Ross, Muriel D. (Inventor); Twombly, Ian Alexander (Inventor); Senger, Steven O. (Inventor)
2003-01-01
A virtual interactive imaging system allows the displaying of high-resolution, three-dimensional images of medical data to a user and allows the user to manipulate the images, including rotation of images in any of various axes. The system includes a mesh component that generates a mesh to represent a surface of an anatomical object, based on a set of data of the object, such as from a CT or MRI scan or the like. The mesh is generated so as to avoid tears, or holes, in the mesh, providing very high-quality representations of topographical features of the object, particularly at high- resolution. The system further includes a virtual surgical cutting tool that enables the user to simulate the removal of a piece or layer of a displayed object, such as a piece of skin or bone, view the interior of the object, manipulate the removed piece, and reattach the removed piece if desired. The system further includes a virtual collaborative clinic component, which allows the users of multiple, remotely-located computer systems to collaboratively and simultaneously view and manipulate the high-resolution, three-dimensional images of the object in real-time.
Arvind, Hemamalini; Klistorner, Alexander; Graham, Stuart L; Grigg, John R
2006-05-01
Multifocal visual evoked potentials (mfVEPs) have demonstrated good diagnostic capabilities in glaucoma and optic neuritis. This study aimed at evaluating the possibility of simultaneously recording mfVEP for both eyes with dichoptic stimulation using virtual reality goggles and also to determine the stimulus characteristics that yield maximum amplitude. ten healthy volunteers were recruited and temporally sparse pattern pulse stimuli were presented dichoptically using virtual reality goggles. Experiment 1 involved recording responses to dichoptically presented checkerboard stimuli and also confirming true topographic representation by switching off specific segments. Experiment 2 involved monocular stimulation and comparison of amplitude with Experiment 1. In Experiment 3, orthogonally oriented gratings were dichoptically presented. Experiment 4 involved dichoptic presentation of checkerboard stimuli at different levels of sparseness (5.0 times/s, 2.5 times/s, 1.66 times/s and 1.25 times/s), where stimulation of corresponding segments of two eyes were separated by 16.7, 66.7,116.7 & 166.7 ms respectively. Experiment 1 demonstrated good traces in all regions and confirmed topographic representation. However, there was suppression of amplitude of responses to dichoptic stimulation by 17.9+/-5.4% compared to monocular stimulation. Experiment 3 demonstrated similar suppression between orthogonal and checkerboard stimuli (p = 0.08). Experiment 4 demonstrated maximum amplitude and least suppression (4.8%) with stimulation at 1.25 times/s with 166.7 ms separation between eyes. It is possible to record mfVEP for both eyes during dichoptic stimulation using virtual reality goggles, which present binocular simultaneous patterns driven by independent sequences. Interocular suppression can be almost eliminated by using a temporally sparse stimulus of 1.25 times/s with a separation of 166.7 ms between stimulation of corresponding segments of the two eyes.
NASA Astrophysics Data System (ADS)
Bibi, T.; Azahari Razak, K.; Rahman, A. Abdul; Latif, A.
2017-10-01
Landslides are an inescapable natural disaster, resulting in massive social, environmental and economic impacts all over the world. The tropical, mountainous landscape in generally all over Malaysia especially in eastern peninsula (Borneo) is highly susceptible to landslides because of heavy rainfall and tectonic disturbances. The purpose of the Landslide hazard mapping is to identify the hazardous regions for the execution of mitigation plans which can reduce the loss of life and property from future landslide incidences. Currently, the Malaysian research bodies e.g. academic institutions and government agencies are trying to develop a landslide hazard and risk database for susceptible areas to backing the prevention, mitigation, and evacuation plan. However, there is a lack of devotion towards landslide inventory mapping as an elementary input of landslide susceptibility, hazard and risk mapping. The developing techniques based on remote sensing technologies (satellite, terrestrial and airborne) are promising techniques to accelerate the production of landslide maps, shrinking the time and resources essential for their compilation and orderly updates. The aim of the study is to provide a better perception regarding the use of virtual mapping of landslides with the help of LiDAR technology. The focus of the study is spatio temporal detection and virtual mapping of landslide inventory via visualization and interpretation of very high-resolution data (VHR) in forested terrain of Mesilau river, Kundasang. However, to cope with the challenges of virtual inventory mapping on in forested terrain high resolution LiDAR derivatives are used. This study specifies that the airborne LiDAR technology can be an effective tool for mapping landslide inventories in a complex climatic and geological conditions, and a quick way of mapping regional hazards in the tropics.
Dual energy computed tomography for the head.
Naruto, Norihito; Itoh, Toshihide; Noguchi, Kyo
2018-02-01
Dual energy CT (DECT) is a promising technology that provides better diagnostic accuracy in several brain diseases. DECT can generate various types of CT images from a single acquisition data set at high kV and low kV based on material decomposition algorithms. The two-material decomposition algorithm can separate bone/calcification from iodine accurately. The three-material decomposition algorithm can generate a virtual non-contrast image, which helps to identify conditions such as brain hemorrhage. A virtual monochromatic image has the potential to eliminate metal artifacts by reducing beam-hardening effects. DECT also enables exploration of advanced imaging to make diagnosis easier. One such novel application of DECT is the X-Map, which helps to visualize ischemic stroke in the brain without using iodine contrast medium.
2012-01-01
We present a case of a 62-year-old man who underwent total hip arthroplasty for treatment of pathologic femoral neck fracture associated with adefovir dipivoxil-induced osteomalacia. He had a 13-month history of bone pain involving his shoulders, hips, and knee. He received adefovir dipivoxil for treatment of lamivudine-resistant hepatitis B virus infection for 5 years before the occurrence of femoral neck fracture. Orthopedic surgeons should be aware of osteomalacia and pathological hip fracture caused by drug-induced renal dysfunction, which results in Fanconi’s syndrome. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1600344696739249 PMID:22906214
Enhancement pattern of the normal facial nerve at 3.0 T temporal MRI.
Hong, H S; Yi, B-H; Cha, J-G; Park, S-J; Kim, D H; Lee, H K; Lee, J-D
2010-02-01
The purpose of this study was to evaluate the enhancement pattern of the normal facial nerve at 3.0 T temporal MRI. We reviewed the medical records of 20 patients and evaluated 40 clinically normal facial nerves demonstrated by 3.0 T temporal MRI. The grade of enhancement of the facial nerve was visually scaled from 0 to 3. The patients comprised 11 men and 9 women, and the mean age was 39.7 years. The reasons for the MRI were sudden hearing loss (11 patients), Méniàre's disease (6) and tinnitus (7). Temporal MR scans were obtained by fluid-attenuated inversion-recovery (FLAIR) and diffusion-weighted imaging of the brain; three-dimensional (3D) fast imaging employing steady-state acquisition (FIESTA) images of the temporal bone with a 0.77 mm thickness, and pre-contrast and contrast-enhanced 3D spoiled gradient record acquisition in the steady state (SPGR) of the temporal bone with a 1 mm thickness, were obtained with 3.0 T MR scanning. 40 nerves (100%) were visibly enhanced along at least one segment of the facial nerve. The enhanced segments included the geniculate ganglion (77.5%), tympanic segment (37.5%) and mastoid segment (100%). Even the facial nerve in the internal auditory canal (15%) and labyrinthine segments (5%) showed mild enhancement. The use of high-resolution, high signal-to-noise ratio (with 3 T MRI), thin-section contrast-enhanced 3D SPGR sequences showed enhancement of the normal facial nerve along the whole course of the nerve; however, only mild enhancement was observed in areas associated with acute neuritis, namely the canalicular and labyrinthine segment.
Virtual skeletal complex model- and landmark-guided orthognathic surgery system.
Lee, Sang-Jeong; Woo, Sang-Yoon; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Han, Jeong Joon; Yang, Hoon Joo; Hwang, Soon Jung; Yi, Won-Jin
2016-05-01
In this study, correction of the maxillofacial deformities was performed by repositioning bone segments to an appropriate location according to the preoperative planning in orthognathic surgery. The surgery was planned using the patient's virtual skeletal models fused with optically scanned three-dimensional dentition. The virtual maxillomandibular complex (MMC) model of the patient's final occlusal relationship was generated by fusion of the maxillary and mandibular models with scanned occlusion. The final position of the MMC was simulated preoperatively by planning and was used as a goal model for guidance. During surgery, the intraoperative registration was finished immediately using only software processing. For accurate repositioning, the intraoperative MMC model was visualized on the monitor with respect to the simulated MMC model, and the intraoperative positions of multiple landmarks were also visualized on the MMC surface model. The deviation errors between the intraoperative and the final positions of each landmark were visualized quantitatively. As a result, the surgeon could easily recognize the three-dimensional deviation of the intraoperative MMC state from the final goal model without manually applying a pointing tool, and could also quickly determine the amount and direction of further MMC movements needed to reach the goal position. The surgeon could also perform various osteotomies and remove bone interference conveniently, as the maxillary tracking tool could be separated from the MMC. The root mean square (RMS) difference between the preoperative planning and the intraoperative guidance was 1.16 ± 0.34 mm immediately after repositioning. After surgery, the RMS differences between the planning and the postoperative computed tomographic model were 1.31 ± 0.28 mm and 1.74 ± 0.73 mm for the maxillary and mandibular landmarks, respectively. Our method provides accurate and flexible guidance for bimaxillary orthognathic surgery based on intraoperative visualization and quantification of deviations for simulated postoperative MMC and landmarks. The guidance using simulated skeletal models and landmarks can complement and improve conventional navigational surgery for bone repositioning in the craniomaxillofacial area. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Gene Expression and Structural Skeletal Responses to Long-Duration Simulated Microgravity in Rats
NASA Technical Reports Server (NTRS)
Shirazi-Fard, Yasaman; Rael, Victoria E.; Torres, Samantha; Steczina, Sonette; Bryant, Sheenah; Tahimic, Candice; Globus, Ruth K.
2017-01-01
In this study, we aim to examine skeletal responses to simulated long-duration spaceflight (90 days) and weight-bearing recovery on bone loss using the ground-based hindlimb unloading (HU) model in adolescent (3-month old) male rats. We hypothesized that simulated microgravity leads to the temporal regulation of oxidative defense genes and pro-bone resorption factors, where there is a progression and eventual plateau; furthermore, early transient changes in these pathways precede skeletal adaptations.
Headache of a diagnosis: frontotemporal pain and inflammation associated with osteolysis.
Tacon, Lyndal J; Parkinson, Jonathon F; Hudson, Bernard J; Brewer, Janice M; Little, Nicholas S; Clifton-Bligh, Roderick J
2008-11-17
A 62-year-old woman presented with left frontotemporal pain, scalp tenderness and raised levels of inflammatory markers. Temporal arteritis was considered likely, and symptoms resolved with prednisone therapy. This delayed diagnostic bone biopsy until a soft tissue abscess formed, and Pott's puffy tumour associated with Prevotella osteomyelitis of the frontal bone was diagnosed. This case highlights the value of early histopathological examination, and is a reminder of a condition seen frequently in the pre-antibiotic era.
Bilateral traumatic facial paralysis. Case report.
Undabeitia, Jose; Liu, Brian; Pendleton, Courtney; Nogues, Pere; Noboa, Roberto; Undabeitia, Jose Ignacio
2013-01-01
Although traumatic injury of the facial nerve is a relatively common condition in neurosurgical practice, bilateral lesions related to fracture of temporal bones are seldom seen. We report the case of a 38-year-old patient admitted to Intensive Care Unit after severe head trauma requiring ventilatory support (Glasgow Coma Scale of 7 on admission). A computed tomography (CT) scan confirmed a longitudinal fracture of the right temporal bone and a transversal fracture of the left. After successful weaning from respirator, bilateral facial paralysis was observed. The possible aetiologies for facial diplegia differ from those of unilateral injury. Due to the lack of facial asymmetry, it can be easily missed in critically ill patients, and both the high resolution CT scan and electromyographic studies can be helpful for correct diagnosis. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Inner ear abnormalities in patients with Goldenhar syndrome.
Bisdas, Sotirios; Lenarz, Minoo; Lenarz, Thomas; Becker, Hartmut
2005-05-01
The objective of this study is to investigate the inner ear malformations in patients with Goldenhar syndrome and to hypothesize the potential embryopathogenesis of these malformations. Retrospective case review. Tertiary referral center. Fourteen patients with Goldenhar syndrome. Each patient underwent hearing tests and high-resolution computed tomography (CT) of the temporal bone. In six patients, magnetic resonance imaging of the temporal bone also was performed. Among the 14 patients with Goldenhar syndrome, 13 had outer and middle ear anomalies and 5 (36%) had inner ear malformations, including one case of common cavity. Our observations regarding inner ear anomalies in Goldenhar syndrome correlate with the reported cases in the literature and may help to hypothesize the embryological origin of these malformations, which can caused by an early developmental arrest in the fourth gestational week. Specialists evaluating patients with Goldenhar syndrome should be aware of the possibility of inner ear malformations, which could be diagnosed earlier with appropriate imaging studies.
Tracking modern human population history from linguistic and cranial phenotype
Reyes-Centeno, Hugo; Harvati, Katerina; Jäger, Gerhard
2016-01-01
Languages and genes arguably follow parallel evolutionary trajectories, descending from a common source and subsequently differentiating. However, although common ancestry is established within language families, it remains controversial whether language preserves a deep historical signal. To address this question, we evaluate the association between linguistic and geographic distances across 265 language families, as well as between linguistic, geographic, and cranial distances among eleven populations from Africa, Asia, and Australia. We take advantage of differential population history signals reflected by human cranial anatomy, where temporal bone shape reliably tracks deep population history and neutral genetic changes, while facial shape is more strongly associated with recent environmental effects. We show that linguistic distances are strongly geographically patterned, even within widely dispersed groups. However, they are correlated predominantly with facial, rather than temporal bone, morphology, suggesting that variation in vocabulary likely tracks relatively recent events and possibly population contact. PMID:27833101
New approaches to pharmacological treatment of osteoporosis.
Akesson, Kristina
2003-01-01
Osteoporosis has been recognized as a major public health problem for less than two decades. The increasing incidence of fragility fractures, such as vertebral, hip, and wrist fractures, first became apparent from epidemiological studies in the early and mid-1980s, when effective treatment was virtually unavailable. Pharmacological therapies that effectively reduce the number of fractures by improving bone mass are now available widely in countries around the world. Most current agents inhibit bone loss by reducing bone resorption, but emerging therapies may increase bone mass by directly promoting bone formation--as is the case with parathyroid hormone. Current treatment alternatives include bisphosphonates, calcitonin, and selective estrogen receptor modulators, but sufficient calcium and vitamin D are a prerequisite. The availability of evidence-based data that show reductions in the incidence of fractures of 30-50% during treatment has been a major step forward in the pharmacological prevention of fractures. With all agents, fracture reduction is most pronounced for vertebral fracture in high-risk individuals; alendronate and risedronate also may protect against hip fracture in the elderly. New approaches to pharmacological treatment will include further development of existing drugs, especially with regard to tolerance and frequency of dosing. New avenues for targeting the condition will emerge as our knowledge of the regulatory mechanisms of bone remodelling increases, although issues of tissue specificity may be difficult to solve. In the long term, information gained through knowledge of bone genetics may be used to adapt pharmacological treatments more precisely to each individual. PMID:14710507
Polycystin-1 interacts with TAZ to stimulate osteoblastogenesis and inhibit adipogenesis
Xiao, Zhousheng; Baudry, Jerome; Cao, Li; ...
2017-11-27
The molecular mechanisms that transduce the osteoblast response to physical forces in the bone microenvironment are poorly understood. In this paper, we used genetic and pharmacological experiments to determine whether the polycystins PC1 and PC2 (encoded by Pkd1 and Pkd2) and the transcriptional coactivator TAZ form a mechanosensing complex in osteoblasts. Compound-heterozygous mice lacking 1 copy of Pkd1 and Taz exhibited additive decrements in bone mass, impaired osteoblast-mediated bone formation, and enhanced bone marrow fat accumulation. Bone marrow stromal cells and osteoblasts derived from these mice showed impaired osteoblastogenesis and enhanced adipogenesis. Increased extracellular matrix stiffness and application of mechanicalmore » stretch to multipotent mesenchymal cells stimulated the nuclear translocation of the PC1 C-terminal tail/TAZ (PC1-CTT/TAZ) complex, leading to increased runt-related transcription factor 2–mediated (Runx2-mediated) osteogenic and decreased PPARγ-dependent adipogenic gene expression. Using structure-based virtual screening, we identified a compound predicted to bind to PC2 in the PC1:PC2 C-terminal tail region with helix:helix interaction. This molecule stimulated polycystin- and TAZ-dependent osteoblastogenesis and inhibited adipogenesis. Therefore, we show that polycystins and TAZ integrate at the molecular level to reciprocally regulate osteoblast and adipocyte differentiation, indicating that the polycystins/TAZ complex may be a potential therapeutic target to increase bone mass.« less
Polycystin-1 interacts with TAZ to stimulate osteoblastogenesis and inhibit adipogenesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Zhousheng; Baudry, Jerome; Cao, Li
The molecular mechanisms that transduce the osteoblast response to physical forces in the bone microenvironment are poorly understood. In this paper, we used genetic and pharmacological experiments to determine whether the polycystins PC1 and PC2 (encoded by Pkd1 and Pkd2) and the transcriptional coactivator TAZ form a mechanosensing complex in osteoblasts. Compound-heterozygous mice lacking 1 copy of Pkd1 and Taz exhibited additive decrements in bone mass, impaired osteoblast-mediated bone formation, and enhanced bone marrow fat accumulation. Bone marrow stromal cells and osteoblasts derived from these mice showed impaired osteoblastogenesis and enhanced adipogenesis. Increased extracellular matrix stiffness and application of mechanicalmore » stretch to multipotent mesenchymal cells stimulated the nuclear translocation of the PC1 C-terminal tail/TAZ (PC1-CTT/TAZ) complex, leading to increased runt-related transcription factor 2–mediated (Runx2-mediated) osteogenic and decreased PPARγ-dependent adipogenic gene expression. Using structure-based virtual screening, we identified a compound predicted to bind to PC2 in the PC1:PC2 C-terminal tail region with helix:helix interaction. This molecule stimulated polycystin- and TAZ-dependent osteoblastogenesis and inhibited adipogenesis. Therefore, we show that polycystins and TAZ integrate at the molecular level to reciprocally regulate osteoblast and adipocyte differentiation, indicating that the polycystins/TAZ complex may be a potential therapeutic target to increase bone mass.« less
Does virtual reality simulation have a role in training trauma and orthopaedic surgeons?
Bartlett, J D; Lawrence, J E; Stewart, M E; Nakano, N; Khanduja, V
2018-05-01
Aims The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research. Materials and Methods A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results' titles, abstracts, and references were examined for relevance. Results A total of 31 articles published between 2004 and 2016 and relating to the objective validity and efficacy of specific virtual reality orthopaedic surgical simulators were identified. We found 18 studies demonstrating the construct validity of 16 different orthopaedic virtual reality simulators by comparing expert and novice performance. Eight studies have demonstrated skill acquisition on a simulator by showing improvements in performance with repeated use. A further five studies have demonstrated measurable improvements in operating theatre performance following a period of virtual reality simulator training. Conclusion The demonstration of 'real-world' benefits from the use of VR simulation in knee and shoulder arthroscopy is promising. However, evidence supporting its utility in other forms of orthopaedic surgery is lacking. Further studies of validity and utility should be combined with robust analyses of the cost efficiency of validated simulators to justify the financial investment required for their use in orthopaedic training. Cite this article: Bone Joint J 2018;100-B:559-65.
A new method for selecting auricle positions in skull base reconstruction for temporal bone cancer.
Tanaka, Kentaro; Yano, Tomoyuki; Homma, Tsutomu; Tsunoda, Atsunobu; Aoyagi, Masaru; Kishimoto, Seiji; Okazaki, Mutsumi
2018-03-25
In advanced temporal bone carcinoma cases, we attempted to preserve as much of the auricle as possible from a cosmetic and functional perspective. Difficulties are associated with selecting an adequate position for reconstructed auricles intraoperatively. We improved the surgical procedure to achieve a good postoperative auricle position. Nine patients were included in this study. All patients underwent subtotal removal of the temporal bone and resection of the external auditory canal while preserving most of the external ear, and lateral skull base reconstruction was performed with anterolateral thigh flaps. We invented a new device, the auricle localizer, to select the correct position for the replaced external ear. The head skin incision line and two points of three-point pin fixation were used as criteria, and a Kirschner wire was shaped as a basic line to match these criteria. Another Kirschner wire was shaped by wrapping it around the inferior edge of the external ear as the positioning line, and these two lines were then combined. To evaluate the postoperative auricle position, the auricle inclination angle was measured using head frontal cephalogram imaging. The external ear on the affected side clearly drooped postoperatively in nonlocalizer cases, whereas this was not obvious in localizer cases. Auricle inclination angles 1 year after surgery significantly differed between these two cases (P = 0.018). The surgical device, the auricle localizer, is useful for selecting intraoperative accurate auricle positions. The assessment index, the auricle inclination angle, is useful for quantitatively evaluating postoperative results. 4 Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
Park, Edward; Amoodi, Hosam; Kuthubutheen, Jafri; Chen, Joseph M; Nedzelski, Julian M; Lin, Vincent Y W
2015-05-28
Cochlear implantation has become a mainstream treatment option for patients with severe to profound sensorineural hearing loss. During cochlear implant, there are key surgical steps which are influenced by anatomical variations between each patient. The aim of this study is to determine if there are potential predictors of difficulties that may be encountered during the cortical mastoidectomy, facial recess approach and round window access in cochlear implant surgery based upon pre-operative temporal bone CT scan. Fifty seven patients undergoing unilateral cochlear implantation were analyzed. Difficulty with 1) cortical mastoidectomy, 2) facial recess approach, and 3) round window access were scored intra-operatively by the surgeon in a blinded fashion (1 = "easy", 2 = "moderate", 3 = "difficult"). Pre-operative temporal bone CT scans were analyzed for 1) degree of mastoid aeration; 2) location of the sigmoid sinus; 3) height of the tegmen; 4) the presence of air cells in the facial recess, and 5) degree of round window bony overhang. Poor mastoid aeration and lower tegmen position, but not the location of sigmoid sinus, are associated with greater difficulty with the cortical mastoidectomy. Presence of an air cell around the facial nerve was predictive of easier facial recess access. However, the degree of round window bony overhang was not predictive of difficulty associated with round window access. Certain parameters on the pre-operative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery.
Harvati, Katerina; Weaver, Timothy D
2006-12-01
Cranial morphology is widely used to reconstruct evolutionary relationships, but its reliability in reflecting phylogeny and population history has been questioned. Some cranial regions, particularly the face and neurocranium, are believed to be influenced by the environment and prone to convergence. Others, such as the temporal bone, are thought to reflect more accurately phylogenetic relationships. Direct testing of these hypotheses was not possible until the advent of large genetic data sets. The few relevant studies in human populations have had intriguing but possibly conflicting results, probably partly due to methodological differences and to the small numbers of populations used. Here we use three-dimensional (3D) geometric morphometrics methods to test explicitly the ability of cranial shape, size, and relative position/orientation of cranial regions to track population history and climate. Morphological distances among 13 recent human populations were calculated from four 3D landmark data sets, respectively reflecting facial, neurocranial, and temporal bone shape; shape and relative position; overall cranial shape; and centroid sizes. These distances were compared to neutral genetic and climatic distances among the same, or closely matched, populations. Results indicate that neurocranial and temporal bone shape track neutral genetic distances, while facial shape reflects climate; centroid size shows a weak association with climatic variables; and relative position/orientation of cranial regions does not appear correlated with any of these factors. Because different cranial regions preserve population history and climate signatures differentially, caution is suggested when using cranial anatomy for phylogenetic reconstruction. Copyright (c) 2006 Wiley-Liss, Inc.
Increasing hip fractures in patients receiving hemodialysis and peritoneal dialysis.
Mathew, Anna T; Hazzan, Azzour; Jhaveri, Kenar D; Block, Geoffrey A; Chidella, Shailaja; Rosen, Lisa; Wagner, John; Fishbane, Steve
2014-01-01
Dialysis patients are at increased risk for hip fractures. Because changes in treatment of metabolic bone disease in this population may have impacted bone fragility, this study aims to analyze the longitudinal risk for fractures in hemodialysis (HD) and peritoneal dialysis (PD) patients. Using the United States Renal Data System database from 1992 to 2009, the temporal trend in hip fractures requiring hospitalization was analyzed using an overdispersed Poisson regression model. Generalized Estimating Equations were used to assess the adjusted effect of dialysis modality on hip fractures. 842,028 HD and 87,086 PD patients were included. There was a significant temporal increase in hip fractures in both HD and PD with stabilization of rates after 2005. With stratification, the increase in fractures occurred in patients who were white and over 65 years of age. In adjusted analyses, HD patients had 1.6 times greater odds of hip fracture than PD patients (OR 1.60 95% CI 1.52, 1.68, p < 0.001). In contrast to the declining hip fracture rates in the general population, we identified a temporal rise in incidence of hip fractures in HD and PD patients. HD patients were at a higher risk for hip fractures than PD patients after adjustment for recognized bone fragility risk factors. The increase in fracture rate over time was limited to older white patients in both HD and PD, the demographics being consistent with osteoporosis risk. Further research is indicated to better understand the longitudinal trend in hip fractures and the discordance between HD and PD. © 2014 S. Karger AG, Basel.
Nawathe, Shashank; Yang, Haisheng; Fields, Aaron J; Bouxsein, Mary L; Keaveny, Tony M
2015-05-01
The influence of the ductility of bone tissue on whole-bone strength represents a fundamental issue of multi-scale biomechanics. To gain insight, we performed a computational study of 16 human proximal femurs and 12 T9 vertebral bodies, comparing the whole-bone strength for the two hypothetical bounding cases of fully brittle versus fully ductile tissue-level failure behaviors, all other factors, including tissue-level elastic modulus and yield stress, held fixed. For each bone, a finite element model was generated (60-82 μm element size; up to 120 million elements) and was virtually loaded in habitual (stance for femur, compression for vertebra) and non-habitual (sideways fall, only for femur) loading modes. Using a geometrically and materially non-linear model, the tissue was assumed to be either fully brittle or fully ductile. We found that, under habitual loading, changing the tissue behavior from fully ductile to fully brittle reduced whole-bone strength by 38.3±2.4% (mean±SD) and 39.4±1.9% for the femur and vertebra, respectively (p=0.39 for site difference). These reductions were remarkably uniform across bones, but (for the femur) were greater for non-habitual (57.1±4.7%) than habitual loading (p<0.001). At overall structural failure, there was 5-10-fold less failed tissue for the fully brittle than fully ductile cases. These theoretical results suggest that the whole-bone strength of the proximal femur and vertebra can vary substantially between fully brittle and fully ductile tissue-level behaviors, an effect that is relatively insensitive to bone morphology but greater for non-habitual loading. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yovcheva, Zornitza; van Elzakker, Corné P J M; Köbben, Barend
2013-11-01
Web-based tools developed in the last couple of years offer unique opportunities to effectively support scientists in their effort to collaborate. Communication among environmental researchers often involves not only work with geographical (spatial), but also with temporal data and information. Literature still provides limited documentation when it comes to user requirements for effective geo-collaborative work with spatio-temporal data. To start filling this gap, our study adopted a User-Centered Design approach and first explored the user requirements of environmental researchers working on distributed research projects for collaborative dissemination, exchange and work with spatio-temporal data. Our results show that system design will be mainly influenced by the nature and type of data users work with. From the end-users' perspective, optimal conversion of huge files of spatio-temporal data for further dissemination, accuracy of conversion, organization of content and security have a key role for effective geo-collaboration. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
2011-01-01
Introduction Osteoarthritis (OA) is a complex, multifactorial joint disease affecting both the cartilage and the subchondral bone. Animal models of OA aid in the understanding of the pathogenesis of OA and testing suitable drugs for OA treatment. In this study we characterized the temporal changes in the tibial subchondral bone architecture in a rat model of low-dose monosodium iodoacetate (MIA)-induced OA using in vivo micro-computed tomography (CT). Methods Male Wistar rats received a single intra-articular injection of low-dose MIA (0.2 mg) in the right knee joint and sterile saline in the left knee joint. The animals were scanned in vivo by micro-CT at two, six, and ten weeks post-injection, analogous to early, intermediate, and advanced stages of OA, to assess architectural changes in the tibial subchondral bone. The articular cartilage changes in the tibiae were assessed macroscopically and histologically at ten weeks post-injection. Results Interestingly, tibiae of the MIA-injected knees showed significant bone loss at two weeks, followed by increased trabecular thickness and separation at six and ten weeks. The trabecular number was decreased at all time points compared to control tibiae. The tibial subchondral plate thickness of the MIA-injected knee was increased at two and six weeks and the plate porosity was increased at all time points compared to control. At ten weeks, histology revealed loss of proteoglycans, chondrocyte necrosis, chondrocyte clusters, cartilage fibrillation, and delamination in the MIA-injected tibiae, whereas the control tibiae showed no changes. Micro-CT images and histology showed the presence of subchondral bone sclerosis, cysts, and osteophytes. Conclusions These findings demonstrate that the low-dose MIA rat model closely mimics the pathological features of progressive human OA. The low-dose MIA rat model is therefore suitable to study the effect of therapeutic drugs on cartilage and bone in a non-trauma model of OA. In vivo micro-CT is a non-destructive imaging technique that can track structural changes in the tibial subchondral bone in this animal model, and could also be used to track changes in bone in preclinical drug intervention studies for OA treatments. PMID:22185204
Multiscale biomechanical responses of adapted bone-periodontal ligament-tooth fibrous joints
Jang, Andrew T.; Merkle, Arno; Fahey, Kevin; Gansky, Stuart A.; Ho, Sunita P.
2015-01-01
Reduced functional loads cause adaptations in organs. In this study, temporal adaptations of bone-ligament-tooth fibrous joints to reduced functional loads were mapped using a holistic approach. Systematic studies were performed to evaluate organ-level and tissue-level adaptations in specimens harvested periodically from rats given powder food for 6 months (N = 60 over 8,12,16,20, and 24 weeks). Bone-periodontal ligament (PDL)-tooth fibrous joint adaptation was evaluated by comparing changes in joint stiffness with changes in functional space between the tooth and alveolar bony socket. Adaptations in tissues included mapping changes in the PDL and bone architecture as observed from collagen birefringence, bone hardness and volume fraction in rats fed soft foods (soft diet, SD) compared to those fed hard pellets as a routine diet (hard diet, HD). In situ biomechanical testing on harvested fibrous joints revealed increased stiffness in SD groups (SD:239-605 N/mm) (p<0.05) at 8 and 12 weeks. Increased joint stiffness in early development phase was due to decreased functional space (at 8wks change in functional space was −33 µm, at 12wks change in functional space was −30 µm) and shifts in tissue quality as highlighted by birefringence, architecture and hardness. These physical changes were not observed in joints that were well into function, that is, in rodents older than 12 weeks of age. Significant adaptations in older groups were highlighted by shifts in bone growth (bone volume fraction 24wks: Δ-0.06) and bone hardness (8wks: Δ−0.04 GPa, 16 wks: Δ−0.07 GPa, 24wks: Δ−0.06 GPa). The response rate (N/s) of joints to mechanical loads decreased in SD groups. Results from the study showed that joint adaptation depended on age. The initial form-related adaptation (observed change in functional space) can challenge strain-adaptive nature of tissues to meet functional demands with increasing age into adulthood. The coupled effect between functional space in the bone-PDLtooth complex and strain-adaptive nature of tissues is necessary to accommodate functional demands, and is temporally sensitive despite joint malfunction. From an applied science perspective, we propose that adaptations are registered as functional history in tissues and joints. PMID:26151121
NASA Technical Reports Server (NTRS)
Jiang, Guang-Liang; White, Charles R.; Stevens, Hazel Y.; Frangos, John A.
2002-01-01
Bone cells are subject to interstitial fluid flow (IFF) driven by venous pressure and mechanical loading. Rapid dynamic changes in mechanical loading cause transient gradients in IFF. The effects of pulsatile flow (temporal gradients in fluid shear) on rat UMR106 cells and rat primary osteoblastic cells were studied. Pulsatile flow induced a 95% increase in S-phase UMR106 cells compared with static controls. In contrast, ramped steady flow stimulated only a 3% increase. Similar patterns of S-phase induction were also observed in rat primary osteoblastic cells. Pulsatile flow significantly increased relative UMR106 cell number by 37 and 62% at 1.5 and 24 h, respectively. Pulsatile flow also significantly increased extracellular signal-regulated kinase (ERK1/2) phosphorylation by 418%, whereas ramped steady flow reduced ERK1/2 activation to 17% of control. Correspondingly, retinoblastoma protein was significantly phosphorylated by pulsatile fluid flow. Inhibition of mitogen-activated protein (MAP)/ERK kinase (MEK)1/2 by U0126 (a specific MEK1/2 inhibitor) reduced shear-induced ERK1/2 phosphorylation and cell proliferation. These findings suggest that temporal gradients in fluid shear stress are potent stimuli of bone cell proliferation.
Conservative management of typical pediatric postauricular dermoid cysts.
Linkov, Gary; Kanev, Paul M; Isaacson, Glenn
2015-11-01
Congenital dermoid cysts of the skull and face frequently arise in embryonic fusion planes. They may follow these planes to extend intratemporally or intracranially. Advanced imaging and operative techniques are generally recommended for these lesions. Postauricular temporal bone dermoid cysts seem to form a distinct subgroup with a lesser tendency toward deep extension. They may be amenable to more conservative management strategies. With IRB-approval, we queried a prospectively-accrued computerized patient-care database to find all postauricular temporal dermoid lesions surgically managed by a single pediatric otolaryngologist from 2001 to 2014. We reviewed the English-language literature to identify similar series of surgically treated pediatric temporal bone dermoid cysts. Ten postauricular temporal dermoid cysts with pathological confirmation were identified in our surgical series. The average size of the lesions was 1.5 cm (0.3-3 cm). The average age at time of surgery was 4 years (6 months-17 years). No intracranial extension was observed at surgery. There were no recurrences noted on last follow-up (mean 65 months, range 10-150 months). A computerized literature review found no examples of intracranial extension among typical postauricular dermoid cysts. There was no intracranial or temporal extension in our series or among postauricular lesions described in the literature. Given the low incidence of deep extension we advocate neither advanced imaging nor routine neurosurgical consultation for typical postauricular lesions. Dissection in continuity with cranial periosteum facilitates intact removal of adherent lesions. Surgery is curative if the dermoid is removed intact. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Two-time scale fatigue modelling: application to damage
NASA Astrophysics Data System (ADS)
Devulder, Anne; Aubry, Denis; Puel, Guillaume
2010-05-01
A temporal multiscale modelling applied to fatigue damage evolution in cortical bone is presented. Microdamage accumulation in cortical bone, ensued from daily activities, leads to impaired mechanical properties, in particular by reducing the bone stiffness and inducing fatigue. However, bone damage is also known as a stimulus to bone remodelling, whose aim is to repair and generate new bone, adapted to its environment. This biological process by removing fatigue damage seems essential to the skeleton lifetime. As daily activities induce high frequency cycles (about 10,000 cycles a day), identifying two-time scale is very fruitful: a fast one connected with the high frequency cyclic loading and a slow one related to a quasi-static loading. A scaling parameter is defined between the intrinsic time (bone lifetime of several years) and the high frequency loading (few seconds). An asymptotic approach allows to decouple the two scales and to take into account history effects (Guennouni and Aubry in CR Acad Sci Paris Ser II 20:1765-1767, 1986). The method is here applied to a simple case of fatigue damage and a real cortical bone microstructure. A significant reduction in the amount of computation time in addition to a small computational error between time homogenized and non homogenized models are obtained. This method seems thus to give new perspectives to assess fatigue damage and, with regard to bone, to give a better understanding of bone remodelling.
Martin, Daniel E; Severns, Anne E; Kabo, J M J Michael
2004-08-01
Mechanical tests of bone provide valuable information about material and structural properties important for understanding bone pathology in both clinical and research settings, but no previous studies have produced applicable non-invasive, quantitative estimates of bending stiffness. The goal of this study was to evaluate the effectiveness of using peripheral quantitative computed tomography (pQCT) data to accurately compute the bending stiffness of bone. Normal rabbit humeri (N=8) were scanned at their mid-diaphyses using pQCT. The average bone mineral densities and the cross-sectional moments of inertia were computed from the pQCT cross-sections. Bending stiffness was determined as a function of the elastic modulus of compact bone (based on the local bone mineral density), cross-sectional moment of inertia, and simulated quasistatic strain rate. The actual bending stiffness of the bones was determined using four-point bending tests. Comparison of the bending stiffness estimated from the pQCT data and the mechanical bending stiffness revealed excellent correlation (R2=0.96). The bending stiffness from the pQCT data was on average 103% of that obtained from the four-point bending tests. The results indicate that pQCT data can be used to accurately determine the bending stiffness of normal bone. Possible applications include temporal quantification of fracture healing and risk management of osteoporosis or other bone pathologies.
Gambardella, Alessandra; Nagaraju, Chandan K; O'Shea, Patrick J; Mohanty, Sindhu T; Kottam, Lucksy; Pilling, James; Sullivan, Michael; Djerbi, Mounira; Koopmann, Witte; Croucher, Peter I; Bellantuono, Ilaria
2011-04-01
Small molecules are attractive therapeutics to amplify and direct differentiation of stem cells. They also can be used to understand the regulation of their fate by interfering with specific signaling pathways. Mesenchymal stem cells (MSCs) have the potential to proliferate and differentiate into several cell types, including osteoblasts. Activation of canonical Wnt signaling by inhibition of glycogen synthase kinase 3 (GSK-3) has been shown to enhance bone mass, possibly by involving a number of mechanisms ranging from amplification of the mesenchymal stem cell pool to the commitment and differentiation of osteoblasts. Here we have used a highly specific novel inhibitor of GSK-3, AR28, capable of inducing β-catenin nuclear translocation and enhanced bone mass after 14 days of treatment in BALB/c mice. We have shown a temporally regulated increase in the number of colony-forming units-osteoblast (CFU-O) and -adipocyte (CFU-A) but not colony-forming units-fibroblast (CFU-F) in mice treated for 3 days. However, the number of CFU-O and CFU-A returned to normal levels after 14 days of treatment, and the number of CFU-F was decreased significantly. In contrast, the number of osteoblasts increased significantly only after 14 days of treatment, and this was seen together with a significant decrease in bone marrow adiposity. These data suggest that the increased bone mass is the result of an early temporal wave of amplification of a subpopulation of MSCs with both osteogenic and adipogenic potential, which is driven to osteoblast differentiation at the expense of adipogenesis. Copyright © 2011 American Society for Bone and Mineral Research.
Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H
2016-10-01
A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.
Bone modeling and remodeling: potential as therapeutic targets for the treatment of osteoporosis.
Langdahl, Bente; Ferrari, Serge; Dempster, David W
2016-12-01
The adult skeleton is renewed by remodeling throughout life. Bone remodeling is a process where osteoclasts and osteoblasts work sequentially in the same bone remodeling unit. After the attainment of peak bone mass, bone remodeling is balanced and bone mass is stable for one or two decades until age-related bone loss begins. Age-related bone loss is caused by increases in resorptive activity and reduced bone formation. The relative importance of cortical remodeling increases with age as cancellous bone is lost and remodeling activity in both compartments increases. Bone modeling describes the process whereby bones are shaped or reshaped by the independent action of osteoblast and osteoclasts. The activities of osteoblasts and osteoclasts are not necessarily coupled anatomically or temporally. Bone modeling defines skeletal development and growth but continues throughout life. Modeling-based bone formation contributes to the periosteal expansion, just as remodeling-based resorption is responsible for the medullary expansion seen at the long bones with aging. Existing and upcoming treatments affect remodeling as well as modeling. Teriparatide stimulates bone formation, 70% of which is remodeling based and 20-30% is modeling based. The vast majority of modeling represents overflow from remodeling units rather than de novo modeling. Denosumab inhibits bone remodeling but is permissive for modeling at cortex. Odanacatib inhibits bone resorption by inhibiting cathepsin K activity, whereas modeling-based bone formation is stimulated at periosteal surfaces. Inhibition of sclerostin stimulates bone formation and histomorphometric analysis demonstrated that bone formation is predominantly modeling based. The bone-mass response to some osteoporosis treatments in humans certainly suggests that nonremodeling mechanisms contribute to this response and bone modeling may be such a mechanism. To date, this has only been demonstrated for teriparatide, however, it is clear that rediscovering a phenomenon that was first observed more half a century ago will have an important impact on our understanding of how new antifracture treatments work.
Cortés, Daniel; Sylvester, Daniel Cortés; Exss, Eduardo; Marholz, Carlos; Millas, Rodrigo; Moncada, Gustavo
2011-04-01
The aim of this study was to determine the frequency and relationship between disk position and degenerative bone changes in the temporomandibular joints (TMJ), in subjects with internal derangement (ID). MRI and CT scans of 180 subjects with temporomandibular disorders (TMD) were studied. Different image parameters or characteristics were observed, such as disk position, joint effusion, condyle movement, degenerative bone changes (flattened, cortical erosions and irregularities), osteophytes, subchondral cysts and idiopathic condyle resorption. The present study concluded that there is a significant association between disk displacement without reduction and degenerative bone changes in patients with TMD. The study also found a high probability of degenerative bone changes when disk displacement without reduction is present. No association was found between TMD and condyle range of motion, joint effusion and/or degenerative bone changes. The following were the most frequent morphological changes observed: flattening of the anterior surface of the condyle; followed by erosions and irregularities of the joint surfaces; flattening of the articular surface of the temporal eminence, subchondral cysts, osteophytes; and idiopathic condyle resorption, in decreasing order.
Dahia, Chitra Lekha; Mahoney, Eric J; Durrani, Atiq A; Wylie, Christopher
2011-06-15
Vertebral growth plates at different postnatal ages were assessed for active intercellular signaling pathways. To generate a spatial and temporal map of the major signaling pathways active in the postnatal mouse lumbar vertebral growth plate. The growth of all long bones is known to occur by cartilaginous growth plates. The growth plate is composed of layers of chondrocyets that actively proliferate, differentiate, die and, are replaced by bone. The role of major cell signaling pathways has been suggested for regulation of the fetal long bones. But not much is known about the molecular or cellular signals that control the postnatal vertebral growth plate and hence postnatal vertebral bone growth. Understanding such molecular mechanisms will help design therapeutic treatments for vertebral growth disorders such as scoliosis. Antibodies against activated downstream intermediates were used to identify cells in the growth plate responding to BMP, TGFβ, and FGF in cryosections of lumbar vertebrae from different postnatal age mice to identify the zones that were responding to these signals. Reporter mice were used to identify the chondrocytes responding to hedgehog (Ihh), and Wnt signaling. We present a spatial/temporal map of these signaling pathways during growth, and differentiation of the mouse lumbar vertebral growth plate. During growth and differentiation of the vertebral growth plate, its different components respond at different times to different intercellular signaling ligands. Response to most of these signals is dramatically downregulated at the end of vertebral growth.
Effect of excitation direction on cochlear macro-mechanics during bone conduction stimulation
NASA Astrophysics Data System (ADS)
Kamieniecki, Konrad; Tudruj, Sylwester; Piechna, Janusz; Borkowski, Paweł
2018-05-01
In many instances of hearing loss, audiological improvement can be made via direct excitation of a temporal bone (i.e., bone conduction). In order to design better and more efficient devices, the macro-mechanics of the bone conduction hearing pathway must be better understood. Based on previous empirical work, numerical models are useful. In this work, we present results of a time-domain Fluid Structure Interaction model that describes stimulation of the bone conduction pathway. The cochlea was modelled as uncoiled and consisted of an oval window, a round window, a basilar membrane and a helicotrema. In order to monitor pressure waves in the perilymph, the fluid was considered compressible. The excitation, in form of sinusoidal velocity, was applied to the cochlea bony walls. The system was excited in three perpendicular directions: along the basilar membrane, perpendicularly to the membrane and transversely to the membrane. The numerical simulation examined which stimulation direction maximally excited the basilar membrane, the pressure distributions for each excitation direction, and the associated mechanics.
NASA Technical Reports Server (NTRS)
Chang, Katarina L.; Pennline, James A.
2013-01-01
During long-duration missions at the International Space Station, astronauts experience weightlessness leading to skeletal unloading. Unloading causes a lack of a mechanical stimulus that triggers bone cellular units to remove mass from the skeleton. A mathematical system of the cellular dynamics predicts theoretical changes to volume fractions and ash fraction in response to temporal variations in skeletal loading. No current model uses image technology to gather information about a skeletal site s initial properties to calculate bone remodeling changes and then to compare predicted bone strengths with the initial strength. The goal of this study is to use quantitative computed tomography (QCT) in conjunction with a computational model of the bone remodeling process to establish initial bone properties to predict changes in bone mechanics during bone loss and recovery with finite element (FE) modeling. Input parameters for the remodeling model include bone volume fraction and ash fraction, which are both computed from the QCT images. A non-destructive approach to measure ash fraction is also derived. Voxel-based finite element models (FEM) created from QCTs provide initial evaluation of bone strength. Bone volume fraction and ash fraction outputs from the computational model predict changes to the elastic modulus of bone via a two-parameter equation. The modulus captures the effect of bone remodeling and functions as the key to evaluate of changes in strength. Application of this time-dependent modulus to FEMs and composite beam theory enables an assessment of bone mechanics during recovery. Prediction of bone strength is not only important for astronauts, but is also pertinent to millions of patients with osteoporosis and low bone density.
Tomographic imaging of bone composition using coherently scattered x rays
NASA Astrophysics Data System (ADS)
Batchelar, Deidre L.; Dabrowski, W.; Cunningham, Ian A.
2000-04-01
Bone tissue consists primarily of calcium hydroxyapatite crystals (bone mineral) and collagen fibrils. Bone mineral density (BMD) is commonly used as an indicator of bone health. Techniques available at present for assessing bone health provide a measure of BMD, but do not provide information about the degree of mineralization of the bone tissue. This may be adequate for assessing diseases in which the collagen-mineral ratio remains constant, as assumed in osteoporosis, but is insufficient when the mineralization state is known to change, as in osteomalacia. No tool exists for the in situ examination of collagen and hydroxyapatite density distributions independently. Coherent-scatter computed tomography (CSCT) is a technique we are developing that produces images of the low- angle scatter properties of tissue. These depend on the molecular structure of the scatterer making it possible to produce material-specific maps of each component in a conglomerate. After corrections to compensate for exposure fluctuations, self-attenuation of scatter and the temporal response of the image intensifier, material-specific images of mineral, collagen, fat and water distributions are obtained. The gray-level in these images provides the volumetric density of each component independently.
Spontaneous mentalizing during an interactive real world task: an fMRI study.
Spiers, Hugo J; Maguire, Eleanor A
2006-01-01
There are moments in everyday life when we need to consider the thoughts and intentions of other individuals in order to act in a socially appropriate manner. Most of this mentalizing occurs spontaneously as we go about our business in the complexity of the real world. As such, studying the neural basis of spontaneous mentalizing has been virtually impossible. Here we devised a means to achieve this by employing a unique combination of functional magnetic resonance imaging (fMRI), a detailed and interactive virtual reality simulation of a bustling familiar city, and a retrospective verbal report protocol. We were able to provide insights into the content of spontaneous mentalizing events and identify the brain regions that underlie them. We found increased activity in a number of regions, namely the right posterior superior temporal sulcus, the medial prefrontal cortex and the right temporal pole associated with spontaneous mentalizing. Furthermore, we observed the right posterior superior temporal sulcus to be consistently active during several different subtypes of mentalizing events. By contrast, medial prefrontal cortex seemed to be particularly involved in thinking about agents that were visible in the environment. Our findings show that it is possible to investigate the neural basis of mentalizing in a manner closer to its true context, the real world, opening up intriguing possibilities for making comparisons with those who have mentalizing problems.
ERIC Educational Resources Information Center
Trust, Torrey
2015-01-01
New technologies seem to have expanded traditional face-to-face communities of practice across spatial and temporal boundaries into "online communities of practice." However, these virtual landscapes are significantly different from the context of face-to-face communities of practice that Lave and Wenger (1991) observed. This study…
The Estuary Data Mapper (EDM) is a free, interactive virtual gateway to coastal data aimed to promote research and aid in environmental management. The graphical user interface allows users to custom select and subset data based on their spatial and temporal interests giving them...
Difference-Sensitive Communities, Networked Learning, and Higher Education: Potentialities and Risks
ERIC Educational Resources Information Center
Papastephanou, Marianna
2005-01-01
Recent emphases on prospects for difference-sensitive virtual communities rely implicity or explicity on some optimist accounts of cyberspace and globalization. It is expected that hybridity, diaspora and fluidity, marking new understandings of spatiality and temporality in a globalized postmodern era, will create new forms of belonging that will…
ERIC Educational Resources Information Center
White, David J.; Congedo, Marco; Ciorciari, Joseph; Silberstein, Richard B.
2012-01-01
Brain oscillatory correlates of spatial navigation were investigated using blind source separation (BSS) and standardized low resolution electromagnetic tomography (sLORETA) analyses of 62-channel EEG recordings. Twenty-five participants were instructed to navigate to distinct landmark buildings in a previously learned virtual reality town…
Simultaneous neural and movement recording in large-scale immersive virtual environments.
Snider, Joseph; Plank, Markus; Lee, Dongpyo; Poizner, Howard
2013-10-01
Virtual reality (VR) allows precise control and manipulation of rich, dynamic stimuli that, when coupled with on-line motion capture and neural monitoring, can provide a powerful means both of understanding brain behavioral relations in the high dimensional world and of assessing and treating a variety of neural disorders. Here we present a system that combines state-of-the-art, fully immersive, 3D, multi-modal VR with temporally aligned electroencephalographic (EEG) recordings. The VR system is dynamic and interactive across visual, auditory, and haptic interactions, providing sight, sound, touch, and force. Crucially, it does so with simultaneous EEG recordings while subjects actively move about a 20 × 20 ft² space. The overall end-to-end latency between real movement and its simulated movement in the VR is approximately 40 ms. Spatial precision of the various devices is on the order of millimeters. The temporal alignment with the neural recordings is accurate to within approximately 1 ms. This powerful combination of systems opens up a new window into brain-behavioral relations and a new means of assessment and rehabilitation of individuals with motor and other disorders.
Designing an ultrafast laser virtual laboratory using MATLAB GUIDE
NASA Astrophysics Data System (ADS)
Cambronero-López, F.; Gómez-Varela, A. I.; Bao-Varela, C.
2017-05-01
In this work we present a virtual simulator developed using the MATLAB GUIDE environment based on the numerical resolution of the nonlinear Schrödinger equation (NLS) and using the split step method for the study of the spatial-temporal propagation of nonlinear ultrashort laser pulses. This allows us to study the spatial-temporal propagation of ultrafast pulses as well as the influence of high-order spectral phases such as group delay dispersion and third-order dispersion on pulse compression in time. The NLS can describe several nonlinear effects, in particular in this paper we consider the Kerr effect, cross-polarized wave generation and cubic-quintic propagation in order to highlight the potential of this equation combined with the GUIDE environment. Graphical user interfaces are commonly used in science and engineering teaching due to their educational value, and have proven to be an effective way to engage and motivate students. Specifically, the interactive graphical interfaces presented provide the visualization of some of the most important nonlinear optics phenomena and allows users to vary the values of the main parameters involved.
An Open Architecture for Defense Virtual Environment Training Systems
2003-09-01
Additionally, in the process, preventing the loss of life is also an important result. VRTEs can provide needed training that might otherwise not be...training is directly valuable in mission accomplishment and in preventing loss of life. "One of the biggest problems in both the military and...simplified; unique bones motion offers lifelike bouncing and twisting. 43 o Complete skeletal and muscle control features. o Inverse Kinematics
Three-dimensional surgical simulation.
Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael
2010-09-01
In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Pessis, Eric; Campagna, Raphaël; Sverzut, Jean-Michel; Bach, Fabienne; Rodallec, Mathieu; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc
2013-01-01
With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.
Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael
2009-01-01
This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308
Real-time tracking of visually attended objects in virtual environments and its application to LOD.
Lee, Sungkil; Kim, Gerard Jounghyun; Choi, Seungmoon
2009-01-01
This paper presents a real-time framework for computationally tracking objects visually attended by the user while navigating in interactive virtual environments. In addition to the conventional bottom-up (stimulus-driven) saliency map, the proposed framework uses top-down (goal-directed) contexts inferred from the user's spatial and temporal behaviors, and identifies the most plausibly attended objects among candidates in the object saliency map. The computational framework was implemented using GPU, exhibiting high computational performance adequate for interactive virtual environments. A user experiment was also conducted to evaluate the prediction accuracy of the tracking framework by comparing objects regarded as visually attended by the framework to actual human gaze collected with an eye tracker. The results indicated that the accuracy was in the level well supported by the theory of human cognition for visually identifying single and multiple attentive targets, especially owing to the addition of top-down contextual information. Finally, we demonstrate how the visual attention tracking framework can be applied to managing the level of details in virtual environments, without any hardware for head or eye tracking.
Kinematic/Dynamic Characteristics for Visual and Kinesthetic Virtual Environments
NASA Technical Reports Server (NTRS)
Bortolussi, Michael R. (Compiler); Adelstein, B. D.; Gold, Miriam
1996-01-01
Work was carried out on two topics of principal importance to current progress in virtual environment research at NASA Ames and elsewhere. The first topic was directed at maximizing the temporal dynamic response of visually presented Virtual Environments (VEs) through reorganization and optimization of system hardware and software. The final results of this portion of the work was a VE system in the Advanced Display and Spatial Perception Laboratory at NASA Ames capable of updating at 60 Hz (the maximum hardware refresh rate) with latencies approaching 30 msec. In the course of achieving this system performance, specialized hardware and software tools for measurement of VE latency and analytic models correlating update rate and latency for different system configurations were developed. The second area of activity was the preliminary development and analysis of a novel kinematic architecture for three Degree Of Freedom (DOF) haptic interfaces--devices that provide force feedback for manipulative interaction with virtual and remote environments. An invention disclosure was filed on this work and a patent application is being pursued by NASA Ames. Activities in these two areas are expanded upon below.
NASA Astrophysics Data System (ADS)
Mayhew, Christopher A.; Mayhew, Craig M.
2009-02-01
Vision III Imaging, Inc. (the Company) has developed Parallax Image Display (PIDTM) software tools to critically align and display aerial images with parallax differences. Terrain features are rendered obvious to the viewer when critically aligned images are presented alternately at 4.3 Hz. The recent inclusion of digital elevation models in geographic data browsers now allows true three-dimensional parallax to be acquired from virtual globe programs like Google Earth. The authors have successfully developed PID methods and code that allow three-dimensional geographical terrain data to be visualized using temporal parallax differences.
Early Onset of Laying and Bumblefoot Favor Keel Bone Fractures.
Gebhardt-Henrich, Sabine G; Fröhlich, Ernst K F
2015-11-27
Numerous studies have demonstrated influences of hybrid, feed, and housing on prevalence of keel bone fractures, but influences of behavior and production on an individual level are less known. In this longitudinal study, 80 white and brown laying hens were regularly checked for keel bone deviations and fractures while egg production was individually monitored using Radio Frequency Identification (RFID) from production until depopulation at 65 weeks of age. These focal birds were kept in eight pens with 20 hens per pen in total. About 62% of the hens had broken keel bones at depopulation. The occurrence of new fractures was temporally linked to egg laying: more new fractures occurred during the time when laying rates were highest. Hens with fractured keel bones at depopulation had laid their first egg earlier than hens with intact keel bones. However, the total number of eggs was neither correlated with the onset of egg laying nor with keel bone fractures. All birds with bumblefoot on both feet had a fracture at depopulation. Hens stayed in the nest for a longer time during egg laying during the ten days after the fracture than during the ten days before the fracture. In conclusion, a relationship between laying rates and keel bone fractures seems likely.
Pugash, D; Lehman, A M; Langlois, S
2014-09-01
Thanatophoric dysplasia, hypochondroplasia and achondroplasia are all caused by FGFR3 (fibroblast growth factor receptor 3) mutations. Neuropathological findings of temporal lobe dysplasia are found in thanatophoric dysplasia, and temporal and occipital lobe abnormalities have been described recently in brain imaging studies of children with hypochondroplasia. We describe twins discordant for achondroplasia, in one of whom the prenatal diagnosis was based on ultrasound and fetal MRI documentation of temporal and occipital lobe abnormalities characteristic of hypochondroplasia, in addition to the finding of short long bones. Despite the intracranial findings suggestive of hypochondroplasia, achondroplasia was confirmed following postnatal clinical and genetic testing. These intracranial abnormalities have not been previously described in a fetus with achondroplasia. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Benchmarking Distance Control and Virtual Drilling for Lateral Skull Base Surgery.
Voormolen, Eduard H J; Diederen, Sander; van Stralen, Marijn; Woerdeman, Peter A; Noordmans, Herke Jan; Viergever, Max A; Regli, Luca; Robe, Pierre A; Berkelbach van der Sprenkel, Jan Willem
2018-01-01
Novel audiovisual feedback methods were developed to improve image guidance during skull base surgery by providing audiovisual warnings when the drill tip enters a protective perimeter set at a distance around anatomic structures ("distance control") and visualizing bone drilling ("virtual drilling"). To benchmark the drill damage risk reduction provided by distance control, to quantify the accuracy of virtual drilling, and to investigate whether the proposed feedback methods are clinically feasible. In a simulated surgical scenario using human cadavers, 12 unexperienced users (medical students) drilled 12 mastoidectomies. Users were divided into a control group using standard image guidance and 3 groups using distance control with protective perimeters of 1, 2, or 3 mm. Damage to critical structures (sigmoid sinus, semicircular canals, facial nerve) was assessed. Neurosurgeons performed another 6 mastoidectomy/trans-labyrinthine and retro-labyrinthine approaches. Virtual errors as compared with real postoperative drill cavities were calculated. In a clinical setting, 3 patients received lateral skull base surgery with the proposed feedback methods. Users drilling with distance control protective perimeters of 3 mm did not damage structures, whereas the groups using smaller protective perimeters and the control group injured structures. Virtual drilling maximum cavity underestimations and overestimations were 2.8 ± 0.1 and 3.3 ± 0.4 mm, respectively. Feedback methods functioned properly in the clinical setting. Distance control reduced the risks of drill damage proportional to the protective perimeter distance. Errors in virtual drilling reflect spatial errors of the image guidance system. These feedback methods are clinically feasible. Copyright © 2017 Elsevier Inc. All rights reserved.