Sample records for viscometers

  1. Note: A portable automatic capillary viscometer for transparent and opaque liquids

    NASA Astrophysics Data System (ADS)

    Soltani Ghalehjooghi, A.; Minaei, S.; Gholipour Zanjani, N.; Beheshti, B.

    2017-07-01

    A portable automatic capillary viscometer, equipped with an AVR microcontroller, was designed and developed. The viscometer was calibrated with Certified Reference Material (CRM) s200 and utilized for measurement of kinematic viscosity. A quadratic equation was developed for calibration of the instrument at various temperatures. Also, a model was developed for viscosity determination in terms of the viscometer dimensions. Development of the portable viscometer provides for on-site monitoring of engine oil viscosity.

  2. 21 CFR 862.2920 - Plasma viscometer for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plasma viscometer for clinical use. 862.2920... Instruments § 862.2920 Plasma viscometer for clinical use. (a) Identification. A plasma viscometer for clinical use is a device intended to measure the viscosity of plasma by determining the time period...

  3. 21 CFR 862.2920 - Plasma viscometer for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plasma viscometer for clinical use. 862.2920... Instruments § 862.2920 Plasma viscometer for clinical use. (a) Identification. A plasma viscometer for clinical use is a device intended to measure the viscosity of plasma by determining the time period...

  4. 21 CFR 862.2920 - Plasma viscometer for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plasma viscometer for clinical use. 862.2920... Instruments § 862.2920 Plasma viscometer for clinical use. (a) Identification. A plasma viscometer for clinical use is a device intended to measure the viscosity of plasma by determining the time period...

  5. 21 CFR 862.2920 - Plasma viscometer for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plasma viscometer for clinical use. 862.2920... Instruments § 862.2920 Plasma viscometer for clinical use. (a) Identification. A plasma viscometer for clinical use is a device intended to measure the viscosity of plasma by determining the time period...

  6. 21 CFR 862.2920 - Plasma viscometer for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plasma viscometer for clinical use. 862.2920... Instruments § 862.2920 Plasma viscometer for clinical use. (a) Identification. A plasma viscometer for clinical use is a device intended to measure the viscosity of plasma by determining the time period...

  7. Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate.

    PubMed

    Kim, Byung Jun; Lee, Seung Yeob; Jee, Solkeun; Atajanov, Arslan; Yang, Sung

    2017-06-20

    In this study, a micro-viscometer is developed for measuring shear-varying blood viscosity over a wide-ranging shear rate. The micro-viscometer consists of 10 microfluidic channel arrays, each of which has a different micro-channel width. The proposed design enables the retrieval of 10 different shear rates from a single flow rate, thereby enabling the measurement of shear-varying blood viscosity with a fixed flow rate condition. For this purpose, an optimal design that guarantees accurate viscosity measurement is selected from a parametric study. The functionality of the micro-viscometer is verified by both numerical and experimental studies. The proposed micro-viscometer shows 6.8% (numerical) and 5.3% (experimental) in relative error when compared to the result from a standard rotational viscometer. Moreover, a reliability test is performed by repeated measurement (N = 7), and the result shows 2.69 ± 2.19% for the mean relative error. Accurate viscosity measurements are performed on blood samples with variations in the hematocrit (35%, 45%, and 55%), which significantly influences blood viscosity. Since the blood viscosity correlated with various physical parameters of the blood, the micro-viscometer is anticipated to be a significant advancement for realization of blood on a chip.

  8. A new simple cone-plate viscometer for hemorheology.

    PubMed

    Wang, X; Liao, F L; Stoltz, J F

    1998-09-01

    The aim of this work was to evaluate a new automatic cone-plate viscometer (LBY-N6, PRECIL, Beijing, China) which was designed for clinical measurements of blood and plasma viscosities. Standard calibrating oils of viscosity varying from 1.85 to 20.5 mPas (conforming to ASTM Standard) were used to test the precision and reproducibility of the device. Then the viscometer was used to measure blood and plasma viscosities. The results were compared with those obtained with a conventional Couette viscometer and a capillary viscometer. The results showed that this new viscometer gave good values of viscosity for standard oils with relative errors lower than 10% at shear rates ranging from 20 to 200 s(-1). It also had a good reproducibility (standard deviations < 3% in most cases). Only the results at low shear rates (< 10 s(-1)) were less identical. As for blood, the relative difference between the results given by LBY-N6 and those obtained by Low Shear 30 was less than 10% at high shear rates. This difference decreased with shear rate and could be partly caused by viscoelastic and thixotropic properties of human blood. A small difference between the values of plasma viscosity obtained by LBY-N6 and the capillary viscometer AMTEC was also observed. In conclusion, this new viscometer can be used a routine tool to determine quickly plasma and blood viscosities in clinical practice at shear rates higher than 20 s(-1).

  9. Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate

    PubMed Central

    Kim, Byung Jun; Lee, Seung Yeob; Jee, Solkeun; Atajanov, Arslan; Yang, Sung

    2017-01-01

    In this study, a micro-viscometer is developed for measuring shear-varying blood viscosity over a wide-ranging shear rate. The micro-viscometer consists of 10 microfluidic channel arrays, each of which has a different micro-channel width. The proposed design enables the retrieval of 10 different shear rates from a single flow rate, thereby enabling the measurement of shear-varying blood viscosity with a fixed flow rate condition. For this purpose, an optimal design that guarantees accurate viscosity measurement is selected from a parametric study. The functionality of the micro-viscometer is verified by both numerical and experimental studies. The proposed micro-viscometer shows 6.8% (numerical) and 5.3% (experimental) in relative error when compared to the result from a standard rotational viscometer. Moreover, a reliability test is performed by repeated measurement (N = 7), and the result shows 2.69 ± 2.19% for the mean relative error. Accurate viscosity measurements are performed on blood samples with variations in the hematocrit (35%, 45%, and 55%), which significantly influences blood viscosity. Since the blood viscosity correlated with various physical parameters of the blood, the micro-viscometer is anticipated to be a significant advancement for realization of blood on a chip. PMID:28632151

  10. Rotational Viscometers--A Subject for Student Projects

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2010-01-01

    Three variants of the rotational viscometer employing a dc motor are considered. The viscometers are highly suitable for liquids of high viscosity, such as glycerol or oils (that is, for [eta] in the range 10-1000 mPa s). The set-ups are very simple and can serve as a first step to designing devices that are more complicated. Experimentation with…

  11. Design of a low cost Zimm-Crothers viscometer: From theory to experiment

    NASA Astrophysics Data System (ADS)

    Courbin, L.; Cristobal, G.; Winckert, M.; Panizza, P.

    2005-09-01

    To accurately measure low viscosities of liquids, we describe how a Zimm-Crothers viscometer works and how to build it. The viscometer involves the action of a rotating magnetic field on a metallic cylinder floating on the liquid to be studied. The principles of electromagnetism and fluid mechanics involved make the viscometer an excellent tool for undergraduate laboratory courses and for measuring the shear viscosity of low viscous fluids. We discuss the advantages and limitations of this inexpensive and easy to use apparatus compared to other classical techniques. Calibrations with Newtonian fluids are explained and experiments with Non-Newtonian materials are discussed.

  12. The Shuttle's Vibration Environment is Compatible with the Oscillating Screen Viscometer

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    The oscillating screen viscometer is designed for useful operation in the vibration environment of the Space Shuttle. The following analysis compares recently analyzed on-orbit vibration data against the viscometer's measured vibration sensitivity. During routine crew activities the effect of the resulting vibration on the precision of the viscosity measurement will be tolerable. However, there is a possible problem if the astronauts use unisolated exercise equipment for extended periods of time.

  13. Interpretation of screen factor measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, T.; Uhl, J.T.; Prud'Homme, R.K.

    1983-08-01

    Screen viscometer measurements give different information about polymer molecular weight and molecular weight distribution than intrinsic viscosity or relative viscosity measurements. This study shows that conventional screen viscometers measure elongation flow properties of solutions, and that for flexible polymers such as polyacrylamides, a sharp transition in conformation from a coiled to a stretched state is observed, which occurs at a Deborah number of 0.5. Conventional screen viscometers operate just above this critical Deborah number. Evidence for this transition in polymer conformation comes from measurements on a modified screen viscometer, from extensive work by Durst and Interhal on the sudden pressuremore » jumps during flow of polyacrylamide solutions through porous media, and from polymer kinetic theory modeling of molecular deformation in flow. ll references.« less

  14. A comparison of capillary and rotational viscometry of aqueous solutions of hypromellose.

    PubMed

    Sklubalová, Z; Zatloukal, Z

    2007-10-01

    A comparison of capillary and rotational viscometry of gentle pseudoplastic solutions of hypromellose (HPMC 4000) by using only single-point value of viscosity is difficult. Single-point comparison becomes topical in consequence to the pharmacopoeial requirement that the apparent viscosity of 2% hypromellose solution should be read at the shear rate of approximately 10 s(-1). This communication is focused on the estimation of the suitable shear rate, D eta, at which the apparent viscosity read using the rotational viscometer is numerically equal to the dynamic viscosity read using a capillary viscometer. For the solutions of HPMC in concentrations up to 2% w/v, the non-linear regression equations generated showed the influencing of the D eta value by the dynamic viscosity and/or by the originally derived linear velocity of the solution flowing through the capillary viscometer tube. To compare the apparent viscosity read using the rotational viscometer with the dynamic viscosity read using capillary viscometer, the exact estimation of the shear rate D eta at which both viscosities are numerically equal is essential since it is markedly affected by the concentration of HPMC solution.

  15. Calibration of the Oscillating Screen Viscometer

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    We have devised a calibration procedure for the oscillating screen viscometer which can provide the accuracy needed for the flight measurement of viscosity near the liquid-vapor critical point of xenon. The procedure, which makes use of the viscometer's wide bandwidth and hydrodynamic similarity, allows the viscometer to be self-calibrating. To demonstrate the validity of this procedure we measured the oscillator's transfer function under a wide variety of conditions. We obtained data using CO2 at temperatures spanning a temperature range of 35 K and densities varying by a factor of 165, thereby encountering viscosity variations as great as 50%. In contrast the flight experiment will be performed over a temperature range of 29 K and at only a single density, and the viscosity is expected to change by less than 40%. The measurements show that, after excluding data above 10 Hz (where frequency-dependent corrections are poorly modeled) and making a plausible adjustment to the viscosity value used at high density, the viscometer's behavior is fully consistent with the use of hydrodynamic similarity for calibration. Achieving this agreement required understanding a 1% anelastic effect present in the oscillator's torsion fiber.

  16. Nonlinear flow affects hydrodynamic forces and neutrophil adhesion rates in cone-plate viscometers.

    PubMed Central

    Shankaran, H; Neelamegham, S

    2001-01-01

    We present a theoretical and experimental analysis of the effects of nonlinear flow in a cone-plate viscometer. The analysis predicts that flow in the viscometer is a function of two parameters, the Reynolds number and the cone angle. Nonlinear flow occurs at high shear rates and causes spatial variations in wall shear stress, collision frequency, interparticle forces and attachment times within the viscometer. We examined the effect of these features on cellular adhesion kinetics. Based on recent data (Taylor, A. D., S. Neelamegham, J. D. Hellums, et al. 1996. Biophys. J. 71:3488-3500), we modeled neutrophil homotypic aggregation as a process that is integrin-limited at low shear and selectin-limited at high shear. Our calculations suggest that selectin and integrin on-rates lie in the order of 10(-2)-10(-4)/s. They also indicate that secondary flow causes positional variations in adhesion efficiency in the viscometer, and that the overall efficiency is dependent not only on the shear rate, but also the sample volume and the cone angle. Experiments performed with isolated neutrophils confirmed these predictions. In these experiments, enhancing secondary flow by increasing the sample volume from 100 to 1000 microl at 1500/s for a 2 degrees cone caused up to an approximately 45% drop in adhesion efficiency. Our results suggest that secondary flow may significantly influence cellular aggregation, platelet activation, and endothelial cell mechanotransduction measurements made in the viscometer over the range of conditions applied in typical biological studies. PMID:11371440

  17. Rotational viscometers—a subject for student projects

    NASA Astrophysics Data System (ADS)

    Kraftmakher, Yaakov

    2010-11-01

    Three variants of the rotational viscometer employing a dc motor are considered. The viscometers are highly suitable for liquids of high viscosity, such as glycerol or oils (that is, for η in the range 10-1000 mPa s). The set-ups are very simple and can serve as a first step to designing devices that are more complicated. Experimentation with the electrical motors used in the viscometers provides a deeper understanding of some of the fundamental laws of electricity and magnetism (Lorentz's force, Faraday's law of electromagnetic induction, and Lenz's law).

  18. Possible ambiguities when testing viscosity in compendial monographs - characterisation of grades of cellulose ethers.

    PubMed

    Doelker, E

    2010-10-01

    The European Pharmacopoeia (Ph. Eur.) monographs for the water-soluble cellulose ethers require viscosity determination, either in the "Tests" section or in the non-mandatory "Functionality-related characteristics" section. Although the derivatives are chemically closely related and used for similar applications, the viscosity tests strongly differ. Some monographs generically speak of the rotating viscometer method (2.2.10) and a fixed shear rate (e.g. 10 s-1), which would necessitate an absolute measuring system, while others recommend the capillary viscometer method for product grades of less than 600 mPa∙s and the rotating viscometer method and given operating conditions for grades of higher nominal viscosity. Viscometer methods also differ between the United States Pharmacopeia/National Formulary (USP/NF) and the Japanese Pharmacopoeia (JP) monographs. In addition, for some cellulose ethers the tests sometimes diverge from one pharmacopoeia to the other, although the three compendiums are in a harmonisation process. But the main issue is that the viscometer methods originally employed by the product manufacturers are often not those described in the corresponding monographs and generally vary from one manufacturer to the other. The aim of this study was therefore to investigate whether such a situation could invalidate the present pharmacopoeial requirements. 2 per cent solutions of several viscosity grades of hydroxyethylcellulose, hypromellose and methylcellulose were prepared and their (apparent) viscosity determined using both relative and absolute viscometer methods. The viscometer method used not only affects the measured viscosity but experimental values generally do not correspond to the product nominal viscosities. It emerges that, in contrast to Newtonian solutions (i.e. those of grades of up to ca. 50 mPa∙s nominal viscosity), some of the viscometer methods currently specified in the monographs are not able unambiguously to characterise the grades exhibiting non-Newtonian behaviour. It is also concluded that, unless the various manufacturers redefine their product viscosity grades using a single compendial test, two strategies could be adopted, both based on the operating conditions specified in the labeling (i.e those of the manufacturer), the test appearing either in the mandatory section if this is acceptable to the pharmacopoeia (like in some USP/NF monographs) or, for the Ph. Eur., in the "Functionality-related characteristics" section.

  19. Novel and facile viscometer using a paper-based microfluidic device

    NASA Astrophysics Data System (ADS)

    Kang, Hyunwoong; Jang, Ilhoon; Song, Simon

    2017-11-01

    In clinical applications, it is important to rapidly estimate the blood viscosity of a patient with a high accuracy and a small sample consumption. Unfortunately, ordinary mechanical viscometers require long analysis time, large volume of sample and skilled person. To address this issue, silicon-based viscometers have been developed, but they are still far from prevail usage in clinical environments due to complexity in process and analysis. Recently, a paper-based microfluidic device is emerged as a new platform for a facile point-of-care diagnostic device due to low cost, disposability and ease of use. Thus, we propose a novel and facile method of measuring a viscosity with a paper-based microfluidic devices and a smartphone. This viscometer utilizes mixing characteristics of two fluid flows in a T-shape channel: one for reference and the other for test fluid. The mixing strongly depends on viscosity difference between the two fluids. Also, the fluids are dyed for colorimetric analysis with a smartphone. We found that the accuracy of viscometer is about 3 percent when it was tested for various glycerin aqueous solutions. More detailed information will be discussed in the presentation. This work was supported by the National Research Foundation of Korea(NRF) Grant funded by the Korea government(MSIP) (No. 2016R1A2B3009541).

  20. Electrofluidic Circuit-Based Microfluidic Viscometer for Analysis of Newtonian and Non-Newtonian Liquids under Different Temperatures.

    PubMed

    Lee, Tse-Ang; Liao, Wei-Hao; Wu, Yi-Fan; Chen, Yeng-Long; Tung, Yi-Chung

    2018-02-06

    This paper reports a microfluidic viscometer with an integrated pressure sensor based on electrofluidic circuits, which are electrical circuits constructed by ionic liquid-filled microfluidic channels. The electrofluidic circuit provides a pressure-sensing scheme with great long-term and thermal stability. The viscosity of the tested fluidic sample is estimated by its flow resistance, which is a function of pressure drop, flow rate, and the geometry of the microfluidic channel. The viscometer can be exploited to measure viscosity of either Newtonian or non-Newtonian power-law fluid under various shear rates (3-500 1/s) and temperatures (4-70 °C) with small sample volume (less than 400 μL). The developed sensor-integrated microfluidic viscometer is made of poly(dimethylsiloxane) (PDMS) with transparent electrofluidic circuit, which makes it feasible to simultaneously image samples under tests. In addition, the entire device is disposable to prevent cross-contamination between samples, which is desired for various chemical and biomedical applications. In the experiments, viscosities of Newtonian fluids, glycerol water solutions with different concentrations and a mixture of pyrogallol and sodium hydroxide (NaOH), and non-Newtonian fluids, xanthan gum solutions and human blood samples, have been characterized. The results demonstrate that the developed microfluidic viscometer provides a convenient and useful platform for practical viscosity characterization of fluidic samples for a wide variety of applications.

  1. Measurement of rheologic property of blood by a falling-ball blood viscometer.

    PubMed

    Eguchi, Yoko; Karino, Takeshi

    2008-04-01

    The viscosity of blood obtained by using a rotational viscometer decreases with the time elapsed from the beginning of measurement until it reaches a constant value determined by the magnitude of shear rate. It is not possible to obtain an initial value of viscosity at time t = 0 that is considered to exhibit an intrinsic property of the fluid by this method. Therefore, we devised a new method by which one can obtain the viscosity of various fluids that are not affected by both the time elapsed from the beginning of measurement and the magnitude of shear rate by considering the balance of the forces acting on a solid spherical particle freely falling in a quiescent viscous fluid. By using the new method, we studied the rheologic behavior of corn syrups, carboxy-methyl cellulose, and human blood; and compared the results with those obtained with a cone-and-plate viscometer. It was found that in the case of corn syrups and washed red cell suspensions in which no red cell aggregate (rouleau) was formed, the viscosity obtained with the two different methods were almost the same. In contrast to this, in the case of the whole blood in which massive aggregates were formed, the viscosity obtained with a falling-ball viscometer was much larger than that obtained with a cone-plate viscometer.

  2. Effect of Bulk Viscosity on the Oscillating Screen Viscometer

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    Close to the critical temperature, the bulk viscosity of the xenon sample will exceed the shear viscosity by more than a factor of a billion. Nevertheless, the viscometer's low operating frequency ensures that the only significant force on the oscillating screen will be due to the shear viscosity.

  3. Method for measuring liquid viscosity and ultrasonic viscometer

    DOEpatents

    Sheen, Shuh-Haw; Lawrence, William P.; Chien, Hual-Te; Raptis, Apostolos C.

    1994-01-01

    An ultrasonic viscometer and method for measuring fluid viscosity are provided. Ultrasonic shear and longitudinal waves are generated and coupled to the fluid. Reflections from the generated ultrasonic shear and longitudinal waves are detected. Phase velocity of the fluid is determined responsive to the detected ultrasonic longitudinal waves reflections. Viscosity of the fluid is determined responsive to the detected ultrasonic shear waves reflections. Unique features of the ultrasonic viscometer include the use of a two-interface fluid and air transducer wedge to measure relative signal change and to enable self calibration and the use of a ratio of reflection coefficients for two different frequencies to compensate for environmental changes, such as temperature.

  4. Behavior of an Aromatic Heterocyclic Polymer in Salt Solution.

    DTIC Science & Technology

    1983-08-01

    corresponding to the LiCl concentrations in the PBI samples. Z9 fet The viscosities of the 20 samples were determined using a #50 Cannon- Fenske viscometer at... Fenske capillary viscometers thermostated at 30 C. From four to six readings were taken and averaged to determine the average flow time of each solution

  5. An Optical Fiber Viscometer Based on Long-Period Fiber Grating Technology and Capillary Tube Mechanism

    PubMed Central

    Wang, Jian-Neng; Tang, Jaw-Luen

    2010-01-01

    This work addresses the development and assessment of a fiber optical viscometer using a simple and low-cost long-period fiber grating (LPFG) level sensor and a capillary tube mechanism. Previous studies of optical viscosity sensors were conducted by using different optical sensing methods. The proposed optical viscometer consists of an LPFG sensor, a temperature-controlled chamber, and a cone-shaped reservoir where gravitational force could cause fluid to flow through the capillary tube. We focused on the use of LPFGs as level sensors and the wavelength shifts were not used to quantify the viscosity values of asphalt binders. When the LPFG sensor was immersed in the constant volume (100 mL) AC-20 asphalt binder, a wavelength shift was observed and acquired using LabVIEW software and GPIB controller. The time spent between empty and 100 mL was calculated to determine the discharge time. We simultaneously measured the LPFG-induced discharge time and the transmission spectra both in hot air and AC-20 asphalt binder at five different temperatures, 60, 80, 100, 135, and 170 Celsius. An electromechanical rotational viscometer was also used to measure the viscosities, 0.15–213.80 Pa·s, of the same asphalt binder at the above five temperatures. A non-linear regression analysis was performed to convert LPFG-induced discharge time into viscosities. Comparative analysis shows that the LPFG-induced discharge time agreed well with the viscosities obtained from the rotational viscometer. PMID:22163519

  6. A Low-Cost Viscometer from an Opto-Mechanical Mouse

    ERIC Educational Resources Information Center

    Doroodmand, Mohammad Mahdi; Maleki, Norooz; Kazemi, Hojjatollah

    2010-01-01

    A simple, sensitive, and portable viscometer has been designed using an opto-mechanical mouse. The viscosity of a fluid is measured using the infrared light-emitting diodes and the optical diodes of an opto-mechanical mouse. These components are positioned near the top and bottom of a glass tube containing the fluid to be measured. The viscosity…

  7. Methods and instrumentation used in practice of clinical haemorheology.

    PubMed

    Dintenfass, L

    1984-01-01

    The aim of practice of clinical haemorheology is to study patients who might present themselves with or without any clinical symptoms but who might suffer from silent or overt cardiovascular disorders, some forms of cancer, anxiety, etc. A presence and a prognosis of these disorders are linked to an increase and/or abnormality of one or more of the blood viscosity factors: blood viscosity, plasma viscosity, red cell aggregation and rigidity, platelet aggregation, ability for formation of thrombi, flow instability, etc. Hyperviscosaemia might be present in spite of normal or low viscosity of the whole blood. Different disorders can be described by 'profiles of viscosity factors' which form a rheological fingerprint specific to a particular disease or a group of disorders. Determination of viscosity factors is carried out utilizing a series of instruments: (a) rotational viscometers, (b) capillary viscometers, (c) erythrocyte sedimentation tubes in 20C and 37C water tanks, (d) variable frequency thrombo-viscometer, (e) slit-capillary photo-viscometer, etc. One known factor which is not measured routinely is 'inversion phenomenon', and this is due to complexity and expense of measurements. Biochemical studies, including fibrinogen assay and estimation of ABO blood groups, are carried out. Effect of drugs on blood viscosity factors can be studied in vitro or in vivo.

  8. Contactless laser viscometer for flowing liquid films

    NASA Astrophysics Data System (ADS)

    Michels, Alexandre F.; Menegotto, Thiago; Grieneisen, Hans-Peter; Horowitz, Flavio

    2005-12-01

    This work briefly reviews recent progress in interferometric monitoring of spin and of dip coating, from a unified point of view, and its application for contactless viscometry of liquid films. Considering the associated models and measurement uncertainties, the method was validated for both coating processes with oil standards of known viscosities and constant refractive indices. Limitations and perspectives for application of the laser viscometer to liquid films with a varying refractive index are also discussed.

  9. Mass-controlled capillary viscometer for a Newtonian liquid: Viscosity of water at different temperatures

    NASA Astrophysics Data System (ADS)

    Digilov, Rafael M.; Reiner, M.

    2007-03-01

    The operation principle of the mass-controlled capillary viscometer is presented for a Newtonian liquid. The derived equation for the temporal changes of the mass in a liquid column draining under gravity through a discharge capillary tube accounts self-consistently for the inertial convective term associated with the acceleration effect. The viscosity of water measured at different temperatures using the new approach is in good agreement with literature data.

  10. Rotational viscometer for high-pressure, high-temperature fluids

    DOEpatents

    Carr, K.R.

    1983-06-06

    The invention is a novel rotational viscometer which is well adapted for use with fluids at high temperatures and/or pressures. In one embodiment, the viscometer include a substantially non-magnetic tube having a closed end and having an open end in communication with a fluid whose viscosity is to be determined. An annular drive magnet is mounted for rotation about the tube. The tube encompasses and supports a rotatable shaft assembly which carries a rotor, or bob, for insertion in the fluid. Affixed to the shaft are (a) a second magnet which is magnetically coupled to the drive magnet and (b) a third magnet. In a typical operation, the drive magnet is rotated to turn the shaft assembly while the shaft rotor is immersed in the fluid. The viscous drag on the rotor causes the shaft assembly to lag the rotation of the drive magnet by an amount which is a function of the amount of viscous drag. A first magnetic pickup generates a waveform whose phase is a function of the angular position of the drive magnet. A second magnetic pickup generates a waveform whose phase is a function of the angular position of the third magnet. Means are provided to generate an output indicative of the phase difference between the two waveforms. The viscometer is comparatively simple, inexpensive, rugged, and does not require shaft seals.

  11. Measurement of rheology of distiller's grain slurries using a helical impeller viscometer.

    PubMed

    Houchin, Tiffany L; Hanley, Thomas R

    2004-01-01

    Current research is focused on developing a process to convert the cellulose and hemicellulose in distiller's grains into fermentable sugars, increasing both ethanol yield and the amount of protein in the remaining solid product. The rheologic properties of distiller's grain slurries were determined for concentrations of 21, 23, and 25%. Distiller's grain slurries are non-Newtonian, heterogeneous fluids subject to particle settling. Traditional methods of viscosity measurement, such as cone-and-plate and concentric cylinder viscometers, are not adequate for these fluids. A helical impeller viscometer was employed to measure impeller torque over a range of rotational speeds. Newtonian and non-Newtonian calibration fluids were utilized to obtain constants that relate shear stresses and shear rates to the experimental data. The Newtonian impeller constant, c, was 151; the non-Newtonian shear rate constant, k, was 10.30. Regression analysis of experimental data was utilized for comparison to power law, Herschel-Bulkley, and Casson viscosity models with regression coefficients exceeding 0.99 in all cases.

  12. Low-cost viscometer based on energy dissipation in viscous liquids

    NASA Astrophysics Data System (ADS)

    Hashimoto, C.; Cristobal, G.; Nicolas, A.; Panizza, P.; Rouch, J.; Ushiki, H.

    2001-04-01

    We describe a new type of low-cost easy-to-use viscometer based on the temperature elevation in a liquid under shear flow. After calibration, this instrument can be used to measure the apparent steady state viscosity for both Newtonian and non-Newtonian liquids with no yield stress. We compute the rise in temperature due to viscous dissipation in a Couette cell and compare it to experimental results for different fluids. We show that the variation of the temperature with shear rate can be used to characterize the rheological behaviour of viscous fluids and to evaluate their viscosity in a large domain, from typically a few cP up to more than 10 P, with an accuracy of about ±5%. In contrast to simple viscometers, non-Newtonian fluids can be studied with this apparatus. We give experimental results for Newtonian and non-Newtonian liquids and show that they are very similar to those given in the literature by using much more sophisticated instruments.

  13. NIST torsion oscillator viscometer response: Performance on the LeRC active vibration isolation platform

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Grodsinsky, Carlos M.

    1992-01-01

    Critical point viscosity measurements are limited to their reduced temperature approach to T(sub c) in an Earth bound system, because of density gradients imposed by gravity. Therefore, these classes of experiments have been proposed as good candidates for 'microgravity' science experiments where this limitation is not present. The nature of these viscosity measurements dictate hardware that is sensitive to low frequency excitations. Because of the vibratory acceleration sensitivity of a torsion oscillator viscometer, used to acquire such measurements, a vibration isolation sensitivity test was performed on candidate 'microgravity' hardware to study the possibility of meeting the stringent oscillatory sensitivity requirements of a National Institute of Standards and Technology (NIST) torsion oscillator viscometer. A prototype six degree of freedom active magnetic isolation system, developed at NASA Lewis Research Center, was used as the isolation system. The ambient acceleration levels of the platform were reduced to the noise floor levels of its control sensors, about one microgravity in the 0.1 to 10 Hz bandwidth.

  14. Measurement system analysis of viscometers used for drilling mud characterization

    NASA Astrophysics Data System (ADS)

    Mat-Shayuti, M. S.; Adzhar, S. N.

    2017-07-01

    Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.

  15. Viscosity of saturated R152a measured with a vibrating wire viscometer

    NASA Astrophysics Data System (ADS)

    van der Gulik, P. S.

    1995-07-01

    Earlier reported values of the viscosity coefficient of the refrigerant R152a (1,1-difluoroethane) have been recalculated with an improved value for the mechanical damping of the vibrating wire viscometer. The measurements were taken along the saturation line both in the saturated liquid and in the saturated vapor every 10 K from 243 up to 393 K by means of a vibrating wire viscometer The damping of the vibration of the wire is a measure for the viscosity provided that the mechanical damping is subtracted. The latter is usually measured in vacuum. It turns out that the damping value measured in this way depends on the vacuum pressure and on the way the wire has been handled before. It appeared that the damping applied previously, measured after 6 days of pumping, is too small, resulting in values of the viscosity coefficient which are too large. The effect on the data for the saturated-liquid viscosity is small, but the new saturated-vapor viscosity data agree much better with the unsaturated-vapor data reported by Takahashi et al.

  16. Electronic drop sensing in microfluidic devices: automated operation of a nanoliter viscometer

    PubMed Central

    Srivastava, Nimisha; Burns, Mark A.

    2007-01-01

    We describe three droplet sensing techniques: a digital electrode, an analog electrode, and a thermal method. All three techniques use a single layer of metal lines that is easy to microfabricate and an electronic signal can be produced using low DC voltages. While the electrode methods utilize changes in electrical conductivity when the air/liquid interface of the droplet passes over a pair of electrodes, the thermal method is based on convective heat loss from a locally heated region. For the electrode method, the analog technique is able to detect 25 nL droplets while the digital technique is capable of detecting droplets as small as 100 pL. For thermal sensing, temperature profiles in the range of 36 °C and higher were used. Finally, we have used the digital electrode method and an array of electrodes located at preset distances to automate the operation of a previously described microfluidic viscometer. The viscometer is completely controlled by a laptop computer, and the total time for operation including setup, calibration, sample addition and viscosity calculation is approximately 4 minutes. PMID:16738725

  17. Study on Measuring the Viscosity of Lubricating Oil by Viscometer Based on Hele - Shaw Principle

    NASA Astrophysics Data System (ADS)

    Li, Longfei

    2017-12-01

    In order to explore the method of accurately measuring the viscosity value of oil samples using the viscometer based on Hele-Shaw principle, three different measurement methods are designed in the laboratory, and the statistical characteristics of the measured values are compared, in order to get the best measurement method. The results show that the oil sample to be measured is placed in the magnetic field formed by the magnet, and the oil sample can be sucked from the same distance from the magnet. The viscosity value of the sample can be measured accurately.

  18. Reliable method for determination of the velocity of a sinker in a high-pressure falling body type viscometer

    NASA Astrophysics Data System (ADS)

    Dindar, Cigdem; Kiran, Erdogan

    2002-10-01

    We present a new sensor configuration and data reduction process to improve the accuracy and reliability of determining the terminal velocity of a falling sinker in falling body type viscometers. This procedure is based on the use of multiple linear variable differential transformer sensors and precise mapping of the sensor signal and position along with the time of fall which is then converted to distance versus fall time along the complete fall path. The method and its use in determination of high-pressure viscosity of n-pentane and carbon dioxide are described.

  19. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  20. Weight-controlled capillary viscometer

    NASA Astrophysics Data System (ADS)

    Digilov, Rafael M.; Reiner, M.

    2005-11-01

    The draining of a water column through a vertical discharge capillary tube is examined with the aid of a force sensor. The change of the mass of the liquid in the column with time is found to be not purely exponential as implied by Poiseuille's law. Using observed residuals associated with a kinetic energy correction, an approximate formula for the mass as a function of time is derived and excellent agreement with experimental data is attained. These results are verified by a viscosity test of distilled water at room temperature. A simple and inexpensive weight-controlled capillary viscometer is proposed that is especially suitable for undergraduate physics and chemistry laboratories.

  1. An automated system for performing continuous viscosity versus temperature measurements of fluids using an Ostwald viscometer

    NASA Astrophysics Data System (ADS)

    Beaulieu, L. Y.; Logan, E. R.; Gering, K. L.; Dahn, J. R.

    2017-09-01

    An automated system was developed to measure the viscosity of fluids as a function of temperature using image analysis tracking software. An Ostwald viscometer was placed in a three-wall dewar in which ethylene glycol was circulated using a thermal bath. The system collected continuous measurements during both heating and cooling cycles exhibiting no hysteresis. The use of video tracking analysis software greatly reduced the measurement errors associated with measuring the time required for the meniscus to pass through the markings on the viscometer. The stability of the system was assessed by performing 38 consecutive measurements of water at 42.50 ± 0.05 °C giving an average flow time of 87.7 ± 0.3 s. A device was also implemented to repeatedly deliver a constant volume of liquid of 11.00 ± 0.03 ml leading to an average error in the viscosity of 0.04%. As an application, the system was used to measure the viscosity of two Li-ion battery electrolyte solvents from approximately 10 to 40 °C with results showing excellent agreement with viscosity values calculated using Gering's Advanced Electrolyte Model (AEM).

  2. Foam generator and viscometer apparatus and process

    DOEpatents

    Reed, Troy D.; Pickell, Mark B.; Volk, Leonard J.

    2004-10-26

    An apparatus and process to generate a liquid-gas-surfactant foam and to measure its viscosity and enable optical and or electronic measurements of physical properties. The process includes the steps of pumping selected and measured liquids and measured gases into a mixing cell. The mixing cell is pressurized to a desired pressure and maintained at a desired pressure. Liquids and gas are mixed in the mixing cell to produce a foam of desired consistency. The temperature of the foam in the mixing cell is controlled. Foam is delivered from the mixing cell through a viscometer under controlled pressure and temperature conditions where the viscous and physical properties of the foam are measured and observed.

  3. Rotational viscometer for high-pressure high-temperature fluids

    DOEpatents

    Carr, Kenneth R.

    1985-01-01

    The invention is a novel rotational viscometer which is well adapted for use with fluids at high temperatures and/or pressures. In one embodiment, the viscometer includes a substantially non-magnetic tube having a closed end and having an open end in communication with a fluid whose viscosity is to be determined. An annular drive magnet is mounted for rotation about the tube. The tube encompasses and supports a rotatable shaft assembly which carries a rotor, or bob, for insertion in the fluid. Affixed to the shaft are (a) a second magnet which is magnetically coupled to the drive magnet and (b) a third magnet. In a typical operation, the drive magnet is rotated to turn the shaft assembly while the shaft rotor is immersed in the fluid. The viscous drag on the rotor causes the shaft assembly to lag the rotation of the drive magnet by an amount which is a function of the amount of viscous drag. A first magnetic pickup generates a waveform whose phase is a function of the angular position of the drive magnet. A second magnetic pickup generates a waveform whose phase is a function of the angular position of the third magnet. An output is generated indicative of the phase difference between the two waveforms.

  4. A hydrodynamic model of the oscillating screen viscometer

    NASA Technical Reports Server (NTRS)

    Davis, A. M. J.

    1993-01-01

    The viscometer consists of an oscillating screen immersed in a fluid and free to rotate about an axis in its plane. The viscosity can be determined from the measured ratio of the periodic driving force to the screen motion when an adequate hydrodynamical model of the immersed oscillator is available. The screen is formed by a square mesh of thin wire whose dimensions invite comparison with asymptotic results for narrow hollow bodies translating in Stokes flow. These indicate that the closed hole structure of the grid plays an important role in determining its motion. It is shown that this role diminishes as the frequency increases. The computed results, obtained from a system of linear equations, are consistent with experimental values over the appropriate range of frequency.

  5. Comparison between sensitivity of a viscometric method and sensitivity of the alkaline elution assay for the determination of DNA damage induced by dimethylsulfate in vitro.

    PubMed

    Parodi, S; Balbi, C; Taningher, M; Abelmoschi, M L; Pala, M; Parodi, G; Santi, L

    1982-03-01

    DNA damage induced by dimethylsulfate (DMS) was measured with a new oscillating crucible viscometer, having a U-shaped circular channel. Rat liver nuclei were treated in vitro. Viscosity was measured by lysing nuclei in an aklaline lysing solution (pH 12.5; 25 degrees C). Nuclei were lysed immediately in the viscometer and released DNA started to uncoil. In control samples the viscosity increased very slowly with time, reaching a maximum only after about 8 h. A progressively more rapid increase in viscosity was seen with increasing concentrations of DMS. The time of DNA disentanglement was sensitive to about 30 times less breaks than the alkaline elution assay.

  6. Microfluidic viscometers for shear rheology of complex fluids and biofluids

    PubMed Central

    Wang, William S.; Vanapalli, Siva A.

    2016-01-01

    The rich diversity of man-made complex fluids and naturally occurring biofluids is opening up new opportunities for investigating their flow behavior and characterizing their rheological properties. Steady shear viscosity is undoubtedly the most widely characterized material property of these fluids. Although widely adopted, macroscale rheometers are limited by sample volumes, access to high shear rates, hydrodynamic instabilities, and interfacial artifacts. Currently, microfluidic devices are capable of handling low sample volumes, providing precision control of flow and channel geometry, enabling a high degree of multiplexing and automation, and integrating flow visualization and optical techniques. These intrinsic advantages of microfluidics have made it especially suitable for the steady shear rheology of complex fluids. In this paper, we review the use of microfluidics for conducting shear viscometry of complex fluids and biofluids with a focus on viscosity curves as a function of shear rate. We discuss the physical principles underlying different microfluidic viscometers, their unique features and limits of operation. This compilation of technological options will potentially serve in promoting the benefits of microfluidic viscometry along with evincing further interest and research in this area. We intend that this review will aid researchers handling and studying complex fluids in selecting and adopting microfluidic viscometers based on their needs. We conclude with challenges and future directions in microfluidic rheometry of complex fluids and biofluids. PMID:27478521

  7. Transient Torque Method: A Fast and Non-Intrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

    NASA Technical Reports Server (NTRS)

    Li, C.; Ban, H.; Lin, B.; Scripa, R. N.; Su, C.; Lehoczky, S. L.; Zhu, S.

    2003-01-01

    A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of semiconducting or metallic melts. The experimental setup is similar to that for the oscillation cup technique. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate along its axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with the published data. The main advantage of the technique is that the measurement can be completed in one or two minutes, as opposed to the one or two-hour measurement time required by the oscillation cup technique. The method is non-intrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer if desired.

  8. Transient Torque Method: A Fast and Nonintrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

    NASA Technical Reports Server (NTRS)

    Li, C.; Ban, H.; Lin, B.; Scripa, R. N.; Su, C.-H.; Lehoczky, S. L.; Zhu, S.

    2004-01-01

    A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of liquid metals and molten semiconductors. The experimental setup of the transient torque method is similar to that of the oscillation cup method. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate around its vertical axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with published data. The method is nonintrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer to measure just the viscosity of the melt or as a rotating magnetic field method to determine the electrical conductivity of a melt or a solid if desired.

  9. Analysis of Alcohols.

    ERIC Educational Resources Information Center

    McCullough, Brother Thomas

    1984-01-01

    Presents a novel approach to identification of unknown alcohols using experimental measurements of boiling point and viscosity which are easily obtained without expensive equipment of instrumentation. Provides instructions for preparing capillary viscometer, listing special hints for obtaining good results. (JM)

  10. Capillary Viscometer for Fully Automated Measurement of the Concentration and Shear Dependence of the Viscosity of Macromolecular Solutions

    PubMed Central

    Grupi, Asaf; Minton, Allen P.

    2014-01-01

    The construction and operation of a novel viscometer/rheometer are described. The instrument is designed to measure the viscosity of a macromolecular solution while automatically varying both solute concentration and shear rate. Viscosity is calculated directly from Poiseuille's Law, given the measured difference in pressure between two ends of a capillary tube through which the solution is flowing at a known rate. The instrument requires as little as 0.75 ml of a solution to provide a full profile of viscosity as a function of concentration and shear rate, and can measure viscosities as high as 500 cP and as low as 1 cP, at shear rates between 10 and 2 × 103 s-1. The results of control experiments are presented to document the accuracy and precision of measurement at both low and high concentration of synthetic polymers and proteins. PMID:23130673

  11. Helical screw viscometer

    DOEpatents

    Aubert, J.H.; Chapman, R.N.; Kraynik, A.M.

    1983-06-30

    A helical screw viscometer for the measurement of the viscosity of Newtonian and non-Newtonian fluids comprising an elongated cylindrical container closed by end caps defining a circular cylindrical cavity within the container, a cylindrical rotor member having a helical screw or ribbon flight carried by the outer periphery thereof rotatably carried within the cavity whereby the fluid to be measured is confined in the cavity filling the space between the rotor and the container wall. The rotor member is supported by axle members journaled in the end caps, one axle extending through one end cap and connectable to a drive source. A pair of longitudinally spaced ports are provided through the wall of the container in communication with the cavity and a differential pressure meter is connected between the ports for measuring the pressure drop caused by the rotation of the helical screw rotor acting on the confined fluid for computing viscosity.

  12. High Accuracy Fuel Flowmeter, Phase 1

    NASA Technical Reports Server (NTRS)

    Mayer, C.; Rose, L.; Chan, A.; Chin, B.; Gregory, W.

    1983-01-01

    Technology related to aircraft fuel mass - flowmeters was reviewed to determine what flowmeter types could provide 0.25%-of-point accuracy over a 50 to one range in flowrates. Three types were selected and were further analyzed to determine what problem areas prevented them from meeting the high accuracy requirement, and what the further development needs were for each. A dual-turbine volumetric flowmeter with densi-viscometer and microprocessor compensation was selected for its relative simplicity and fast response time. An angular momentum type with a motor-driven, spring-restrained turbine and viscosity shroud was selected for its direct mass-flow output. This concept also employed a turbine for fast response and a microcomputer for accurate viscosity compensation. The third concept employed a vortex precession volumetric flowmeter and was selected for its unobtrusive design. Like the turbine flowmeter, it uses a densi-viscometer and microprocessor for density correction and accurate viscosity compensation.

  13. A capillary viscometer designed for the characterization of biocompatible ferrofluids

    NASA Astrophysics Data System (ADS)

    Nowak, J.; Odenbach, S.

    2016-08-01

    Suspensions of magnetic nanoparticles are receiving a growing interest in biomedical research. These ferrofluids can, e.g., be used for the treatment of cancer, making use of the drug targeting principle or using an artificially induced heating. To enable a safe application the basic properties of the ferrofluids have to be well understood, including the viscosity of the fluids if an external magnetic field is applied. It is well known that the viscosity of ferrofluids rises if a magnetic field is applied, where the rise depends on shear rate and magnetic field strength. In case of biocompatible ferrofluids such investigations proved to be rather complicated as the experimental setup should be close to the actual application to allow justified predictions of the effects which have to be expected. Thus a capillary viscometer, providing a flow situation comparable to the flow in a blood vessel, has been designed. The glass capillary is exchangeable and different inner diameters can be used. The range of the shear rates has been adapted to the range found in the human organism. The application of an external magnetic field is enabled with two different coil setups covering the ranges of magnetic field strengths required on the one hand for a theoretical understanding of particle interaction and resulting changes in viscosity and on the other hand for values necessary for a potential biomedical application. The results show that the newly designed capillary viscometer is suitable to measure the magnetoviscous effect in biocompatible ferrofluids and that the results appear to be consistent with data measured with rotational rheometry. In addition, a strong change of the flow behaviour of a biocompatible ferrofluid was proven for ranges of the shear rate and the magnetic field strength expected for a potential biomedical application.

  14. Exploratory Characterization of a Perfluoropolyether Oil as a Possible Viscosity Standard at Deepwater Production Conditions of 533 K and 241 MPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baled, Hseen O.; Tapriyal, Deepak; Morreale, Bryan D.

    2013-08-29

    DuPont’s perfluoropolyether oil Krytox® GPL 102 is a promising candidate for the high-temperature, high-pressure Deepwater viscosity standard (DVS). The preferred DVS is a thermally stable liquid that exhibits a viscosity of roughly 20 mPa∙s at 533 K and 241 MPa; a viscosity value representative of light oils found in ultra-deep formations beneath the deep waters of the Gulf of Mexico. A windowed rolling-ball viscometer designed by our team is used to determine the Krytox® GPL 102 viscosity at pressures to 245 MPa and temperatures of 311 K, 372 K, and 533 K. At 533 K and 243 MPa, the Krytox®more » GPL 102 viscosity is (27.2±1.3)mPa∙s. The rolling-ball viscometer viscosity results for Krytox® GPL 102 are correlated with an empirical 10-parameter surface fitting function that yields an MAPD of 3.9 %. A Couette rheometer is also used to measure the Krytox® GPL 102 viscosity, yielding a value of (26.2±1)mPa∙s at 533 K and 241 MPa. The results of this exploratory study suggest that Krytox®GPL 102 is a promising candidate for the DVS, primarily because this fluoroether oil is thermally stable and exhibits a viscosity closer to the targeted value of 20 mPa ∙ s at 533 K and 241 MPa than any other fluid reported to date. Finally and nonetheless, further studies must be conducted by other researcher groups using various types of viscometers and rheometers on samples of Krytox GPL® 102 from the same lot to further establish the properties of Krytox GPL® 102.« less

  15. Effect of adjuvant physical properties on spray characteristics

    USDA-ARS?s Scientific Manuscript database

    The effects of adjuvant physical properties on spray characteristics were studied. Dynamic surface tension was measured with a Sensa Dyne surface tensiometer 6000 using the maximum bubble pressure method. Viscosity was measured with a Brookfield synchro-lectric viscometer model LVT using a UL adap...

  16. Evaluation of Hyaluronic Acid Dilutions at Different Concentrations Using a Quartz Crystal Resonator (QCR) for the Potential Diagnosis of Arthritic Diseases

    PubMed Central

    Ahumada, Luis Armando Carvajal; González, Marco Xavier Rivera; Sandoval, Oscar Leonardo Herrera; Olmedo, José Javier Serrano

    2016-01-01

    The main objective of this article is to demonstrate through experimental means the capacity of the quartz crystal resonator (QCR) to characterize biological samples of aqueous dilutions of hyaluronic acid according to their viscosity and how this capacity may be useful in the potential diagnosis of arthritic diseases. The synovial fluid is viscous due to the presence of hyaluronic acid, synthesized by synovial lining cells (type B), and secreted into the synovial fluid thus making the fluid viscous. In consequence, aqueous dilutions of hyaluronic acid may be used as samples to emulate the synovial fluid. Due to the viscoelastic and pseudo-plastic behavior of hyaluronic acid, it is necessary to use the Rouse model in order to obtain viscosity values comparable with viscometer measures. A Fungilab viscometer (rheometer) was used to obtain reference measures of the viscosity in each sample in order to compare them with the QCR prototype measures. PMID:27879675

  17. Application of a laser trap as a viscometer

    NASA Astrophysics Data System (ADS)

    Cooper, James; Solomon, Rance; Elrod, Samuel; Barnes, Taylor; Crawford, Cameron; Farone, Anthony; Farone, Mary; Erenso, Daniel

    2013-06-01

    A laser tweezer (LT) along with advanced imaging techniques has been widely applied to manipulate and study living as well as nonliving microscopic objects. In this study we present yet another novel application of LTs for a precise measurement of the viscosities of fluids in a micro-volume flow. We have demonstrated this novel application by measuring the viscosity of a fetal bovine serum (FBS) using a LT constructed from a single intensity gradient laser trap. By calibrating the LT using dielectric silica micro-beads in a fluid with a known viscosity, specifically water, and by suspending same size of silica beads in the FBS and trapping with the same trap, we have determined the viscosity of the FBS at different temperatures. We have used the relationship between the trapping and Stoke's drag force for a constant drag speed to determine the viscosity. We have also analyzed the viscosities determined in comparison with corresponding viscosities measured using an Ostwald viscometer.

  18. The viscosity of pāhoehoe lava: In situ syn-eruptive measurements from Kilauea, Hawaii

    NASA Astrophysics Data System (ADS)

    Chevrel, Magdalena Oryaëlle; Harris, Andrew J. L.; James, Mike R.; Calabrò, Laura; Gurioli, Lucia; Pinkerton, Harry

    2018-07-01

    Viscosity is one of the most important physical properties controlling lava flow dynamics. Usually, viscosity is measured in the laboratory where key parameters can be controlled but can never reproduce the natural environment and original state of the lava in terms of crystal and bubble contents, dissolved volatiles, and oxygen fugacity. The most promising approach for quantifying the rheology of molten lava in its natural state is therefore to carry out direct field measurements by inserting a viscometer into the lava while it is flowing. Such in-situ syn-eruptive viscosity measurements are notoriously difficult to perform due to the lack of appropriate instrumentation and the difficulty of working on or near an active lava flow. In the field, rotational viscometer measurements are of particular value as they have the potential to measure the properties of the flow interior rather than an integration of the viscosity of the viscoelastic crust + flow interior. To our knowledge only one field rotational viscometer is available, but logistical constraints have meant that it has not been used for 20 yr. Here, we describe new viscosity measurements made using the refurbished version of this custom-built rotational viscometer, as performed on active pāhoehoe lobes from the 61G lava flow of Kilauea's Pu'u 'Ō'ō eruption in 2016. We successfully measured a viscosity of ∼380 Pa s at strain-rates between 1.6 and 5 s-1 and at 1144 °C. Additionally, synchronous lava sampling allowed us to provide detailed textural and chemical characterization of quenched samples. Application of current physico-chemical models based on this characterization (16 ± 4 vol.% crystals; 50 ± 6 vol.% vesicles), gave viscosity estimates that were approximately compatible with the measured values, highlighting the sensitivity of model-based viscosity estimates on the effect of deformable bubbles. Our measurements also agree on the range of viscosities in comparison to previous field experiments on Hawaiian lavas. Conversely, direct comparison with sub-liquidus rheological laboratory measurements on natural lavas was unsuccessful because recreating field conditions (in particular volatile and bubble content) is so far inaccessible in the laboratory. Our work shows the value of field rotational viscometry fully-integrated with sample characterization to quantify three-phase lava viscosity. Finally, this work suggests the need for the development of a more versatile instrument capable of recording precise measurements at low torque and low strain rate, and with synchronous temperature measurements.

  19. Viscosity and density of methanol/water mixtures at low temperatures

    NASA Technical Reports Server (NTRS)

    Austin, J. G.; Kurata, F.; Swift, G. W.

    1968-01-01

    Viscosity and density are measured at low temperatures for three methanol/water mixtures. Viscosity is determined by a modified falling cylinder method or a calibrated viscometer. Density is determined by the volume of each mixture contained in a calibrated glass cell placed in a constant-temperature bath.

  20. Viscosity Measurement: A Virtual Experiment - Abstract of Issues 9907W

    NASA Astrophysics Data System (ADS)

    Papadopoulos, N.; Pitta, A. T.; Markopoulos, N.; Limniou, M.; Lemos, M. A. N. D. A.; Lemos, F.; Freire, F. G.

    1999-11-01

    Viscosity Measurement: A Virtual Experiment simulates a series of viscosity experiments. Viscosity is an important subject in chemistry and chemical engineering. It is important when dealing with intermolecular forces in liquids and gases and it has enormous relevance in all technological aspects of equipment dealing with liquids or gases. Most university-level chemistry courses include viscosity to some extent. Viscosity Measurement includes three virtual experiments: an Ostwald viscometer simulator, a falling-ball viscometer simulator, and a balance simulator for a simple determination of the density of a liquid. The Ostwald viscometer simulator and the balance simulator allow the student to find out how composition and temperature influence the density and viscosity of an ethanol-water mixture. The falling-ball viscometer simulator allows the student to determine experimentally the size and density of the ball required to measure viscosity of various liquids. Each virtual experiment includes a corresponding theoretical section. Support from the program is sufficient to enable the students to carry out a virtual experiment sensibly and on their own. Preparation is not essential. Students can use the program unsupervised, thus saving staff time and allowing flexibility in students' time. The design of the program interface plays a key role in the success of a simulated experiment. Direct manipulation has greater intuitive appeal than alternative interface forms such as menus and has been observed to provide performance and learning advantages (1). We tried to design an interface that is visually attractive, is user friendly with simple and intuitive navigation, and provides appropriate schematic animations to clarify the principles of the laboratory procedures. The opening screen presents the virtual experiments that can be selected. Clicking an icon takes the student to the appropriate section. Viscosity Measurement allows the student to concentrate on the experiments at hand and not on learning how to use the program. It communicates its ideas visually with pictures and diagrams relegating on-screen text to the minimum required for the student to understand the presentation. A full presentation of viscosity is reserved for the textbook, which the computer cannot replace. It is well established (2) that people read text on a computer screen more slowly and with greater strain than they do text in a book. Moreover, relatively open-ended exploration does not appear to be a successful method of practice, because practice devised by the learner tends, not to be well conceived and well integrated in the students' learning path (3). For every virtual experiment we suggest a set of coherent exercises that highlight what we want students to know before they enter the real laboratory. Acknowledgment The Greek Ministry of Education and the European Community provided financial help to create the New Educational Technologies for the Teaching of Chemistry course that made development of the viscosity simulator possible. Literature Cited

    1. Bensebasat, I.; Todd, P. Int. J. Man-Machine Studies 1993, 38, 369-402.
    2. Gould, J. D.; Alfato, L.; Finn, R.; Haupt, B.; Minununo, A. Human Factors 1987, 26, 497-515.
    3. Wiedenbeck, S.; Zila, P. L. ACM Transactions on Computer-Human Interaction 1997, 4, 169-196.
    Please refer to PDF for better views of the Ostwald viscometer.

  1. Viscosity of ammonia at high temperature and pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, S.B.K.; Storvick, T.S.

    1979-04-01

    The viscosity of ammonia on five isotherms in the temperature range 448 to 598 K and pressures to 121 bar are reported. The measurements were made in a steady-state, capillary flow viscometer. The measurements are estimated to be accurate to better than 0.4% over the full range. 5 figures, 1 table.

  2. Ultra-High Sensitivity Viscometer Based on a Torsion Pendulum

    NASA Astrophysics Data System (ADS)

    Ma, Xiao-Guang; Chen, Lan; Wang, Hai-Yan; Zhang, Jin-Xiu; Xiong, Xiao-Min

    2018-06-01

    Not Available Supported by the National Natural Science Foundation of China under Grant Nos 10974259, 11274391 and 11104357, the Science and Technology Planning Project of Guangdong Province under Grant No 2012B060100003, and the Fundamental Research Funds for the Central Universities under Grant Nos 121gpy36 and 09lgpy29.

  3. Repeatability precision of the falling number procedure under standard and modified methodologies

    USDA-ARS?s Scientific Manuscript database

    The falling number (FN) procedure is used worldwide to assess the integrity of the starch stored within wheat seed. As an indirect measurement of the activity level of alpha-amylase, FN relies on a dedicated viscometer that measures the amount of time needed for a metal stirring rod of precise geome...

  4. The Use of Opto-Electronics in Viscometry.

    ERIC Educational Resources Information Center

    Mazza, R. J.; Washbourn, D. H.

    1982-01-01

    Describes a semi-automatic viscometer which incorporates a microprocessor system and uses optoelectronics to detect flow of liquid through the capillary, flow time being displayed on a timer with accuracy of 0.01 second. The system could be made fully automatic with an additional microprocessor circuit and inclusion of a pump. (Author/JN)

  5. Line Spread as a Visual Clinical Tool for Thickened Liquids

    ERIC Educational Resources Information Center

    Lund, Annelise Masters; Mertz Garcia, Jane; Chambers, Edgar, IV.

    2013-01-01

    Purpose: Preparing modified liquids to a target level of consistency is critical to patients' nutritional care. This study examined the relationship of line spread (i.e., the distance a liquid flows) to viscometer measurements for a variety of product/liquid combinations and determined if flow distance visually differentiated nectar-thick…

  6. Microfluidics Meets Dilute Solution Viscometry: An Undergraduate Laboratory to Determine Polymer Molecular Weight Using a Microviscometer

    ERIC Educational Resources Information Center

    Pety, Stephen J.; Lu, Hang; Thio, Yonathan S.

    2011-01-01

    This paper describes a student laboratory experiment to determine the molecular weight of a polymer sample by measuring the viscosity of dilute polymer solutions in a PDMS microfluidic viscometer. Sample data are given for aqueous solutions of poly(ethylene oxide) (PEO). A demonstration of shear thinning behavior using the microviscometer is…

  7. Low VOC Barrier Coating for Industrial Maintenance

    DTIC Science & Technology

    2007-11-01

    Color - VOC - Total Solids (wt) - Total Solids (volume) - Percent Pigment - Stormer Viscosity - Brookfield Viscosity - Pot Life...17 NTPEP LVBC Testing (R 31-02) ●Formula - Color - VOC - Total Solids (wt) - Total Solids (volume) - Percent Pigment - Stormer ...Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using the Stormer -Type Viscometer D 610 Test Method for Evaluating Degree of

  8. Effects of Metal Ions on Viscosity of Aqueous Sodium Carboxylmethylcellulose Solution and Development of Dropping Ball Method on Viscosity

    ERIC Educational Resources Information Center

    Set, Seng; Ford, David; Kita, Masakazu

    2015-01-01

    This research revealed that metal ions with different charges could significantly affect the viscosity of aqueous sodium carboxylmethylcellulose (CMC) solution. On the basis of an Ostwald viscometer, an improvised apparatus using a dropping ball for examining the viscosity of liquids/solutions has been developed. The results indicate that the…

  9. Measuring Viscosity with a Levitating Magnet: Application to Complex Fluids

    ERIC Educational Resources Information Center

    Even, C.; Bouquet, F.; Remond, J.; Deloche, B.

    2009-01-01

    As an experimental project proposed to students in fourth year of university, a viscometer was developed, consisting of a small magnet levitating in a viscous fluid. The viscous force acting on the magnet is directly measured: viscosities in the range 10-10[superscript 6] mPa s are obtained. This experiment is used as an introduction to complex…

  10. Detection of DNA damage induced in vivo by a cross-linking agent with a circular channel crucible oscillating viscometer.

    PubMed

    Balbi, C; Abelmoschi, M L; Roner, R; Giaretti, W; Parodi, S; Santi, L

    1985-11-01

    DNA damage induced in vivo by the cross-linking agent mitomycin C (MMC) was investigated with a new oscillating crucible viscometer. Viscosity was measured by lysing rat liver nuclei in an alkaline lysing solution (pH 12.5; 25 degrees C). In control samples the viscosity increased very slowly with time, reaching a plateau only after 10-12 h. The process was accelerated and the maximum viscosity was decreased by alkaline single-stranded breaks arising from methylation and subsequent depurination of DNA in vitro with dimethylsulphate (DMS). MMC, when given alone, had no evident effect on the time needed for reaching plateau viscosity but it induced a small increase in maximum viscosity. When MMC was given in association with DMS, the time of disentanglement remained unchanged (accelerated) but maximum viscosity was increased in a dose dependent way. We conclude that these data clearly confirm that the slow steady increase of the viscosity of control DNA with time reflects mainly the process of unwinding of the two strands. The speed of this process seems to depend only from the number of unwinding points in DNA (breaks).

  11. Determining temperature limits of drilling fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thuren, J.B.; Chenevert, M.E.; Huang, W.T.W.

    A capillary three tube viscometer has been designed which allows the measurement of rheological properties of time dependent non-Newtonian fluids in laminar flow at high temperture and pressure. The objective of this investigation is to determine the temperature stability of clay-water suspensions containing various drilling fluid additives. The additives studied consisted of viscosifiers, filtrate reducers, and chemical thinners. The temperature range studied is from room temperature to 550{sup 0}F. The system pressure is consistently maintained above the vapor pressure. The Bentonite and water standardized base mud used is equivalent to a 25 ppB fluid. Stabilization of the base mud ismore » necessary to obtain steady state laminar flow conditions and to obtain reliable temperature thinning effects with each temperature interval under investigation. Generally the temperature levels are maintained for one hour until 550{sup 0}F is attained. The last interval is then maintained until system fluid degradation occurs. Rheological measurements are obtained from differential pressure transducers located in a three diameter tube test section and externally at ambient conditions from a Baroid Rotational Viscometer. The power law model for non-Newtonian fluids is used to correlate the data.« less

  12. Rheological study of clay-kaolin aqueous suspensions

    NASA Technical Reports Server (NTRS)

    Lapasin, R.; Lucchini, F.

    1984-01-01

    Rheological characteristics of clay-kaolin aqueous suspensions were studied by a rotational viscometer to correlate their behavior with the properties of ceramic slips for casting containing quartz, feldspars, and other nonplastic materials. In particular, the effects of the different amounts of dry materials and deflocculant (mixture 1:1 of Na2CO3 and Na2SiO3) and of temperatures on the shear-time-dependent properties of suspensions were examined.

  13. Nonhydrodynamic Characteristics of the Oscillating Screen Viscometer

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    Extraction of the viscosity from the oscillating screen's response function requires knowledge of it resonance frequency omega(sub 0) and of the prefactor k(sub tr)/k(theta), where k(sub tr) is a transducer coefficient and k(sub theta) is the torsion spring constant. The determination of these parameters is described. The effect of a possible anomaly in the dielectric constant near the critical point of xenon will be negligible.

  14. FLUIDS, LUBRICANTS, FUELS AND RELATED MATERIALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klaus, E.E.; Fenske, M.R.; Tewksbury, E.J.

    1961-01-01

    Work was carried out on a continuing program to characterize the capabilities of hydraulic fluids, lubricants, and functional fluids for aeronautic and astronautic applications under extreme environmental conditions. The effects of solvent type and solvent to oil ratio on the deep dewaxing process are shown. The yield and viscosity-temperature properties of the deep dewaxed oil are related to the type and degree of refining of the mineral oil fraction. The preparation of large volumes of super-refined mineral oil formulations for ""mock-up'' testing is reponted. Extensive technical liaison on processing, properties, and application is discussed. Physical and chemical stability of basemore » stocks, additives, and finished hydraulic fluid and lubricant formulations after 5 to 17 years in storage is described. A sample of hydraulic fluid taken from the "Lady Be Good" B-25 Bomber after 16 years in the North African desert is discussed. The design, construction, and preliminary testing of a versatile capillary pressure viscometer is reported. The use of this viscometer to measure the effect of gas solubility on viscosity and the analysis of flow profile in a capillary viscometer are discussed. The use of the pressure unit with a modified Lipkin pycnometer for the measure of bulk modulus is suggested. The thermal stability of esters is contrasted and compared as a function of chemical structure. Quantitative evaluations of the gas produced and the liquid phase are used to illustrate the effect of metal catalysts. The effects of fluid type, viscosity, vapor pressure, oxidation mechanism, oxidation inhibitor, and gaseous environment on evaporation are presented. The use of evaporation tests in studying the mechanism of oxidation is suggested. The relative lubricity properties of a series of high-temperature-bearing materials are reported. The relative effects of fluid volatility on lubricity are discussed. The similarities between high-temperature and the lowtemperatare lubricity properties of the residual fluids after high-temperature oxidation and thermal tests are pointed out. The wear properties of mineral oils and esters with and without lubricity additives are compared and contrasted with silicons and silicate fluids at 167 to 700 deg F. A simple, versatile, quantitative oxidation test is described for use with a variety of high-temperature oxidation tests. (auth)« less

  15. Choosing Polymer Solvents for Microlithography.

    DTIC Science & Technology

    1987-07-24

    of poly(methylmethacrylate) ( PMMA ) were spin coated on three-inch silicon wafers with a native oxide layer. The PMMA used was Formula 950K from KTI...exposure as measured by GPC are shown in Table 3. Viscosities of solutions containing 1% PMMA by weight were measured at 30 0C in an Ubbelohde viscometer...for each of the solvents studied. The PMMA used was first precipitated from a commercial 6% solution of PMMA (Mw-950K) in chlorobenzene obtained from

  16. Microfluidic method for measuring viscosity using images from smartphone

    NASA Astrophysics Data System (ADS)

    Kim, Sooyeong; Kim, Kyung Chun; Yeom, Eunseop

    2018-05-01

    The viscosity of a fluid is the most important characteristic in fluid rheology. Many microfluidic devices have been proposed for easily measuring the fluid viscosity of small samples. A hybrid system consisting of a smartphone and microfluidic device can offer a mobile laboratory for performing a wide range of detection and analysis functions related to healthcare. In this study, a new mobile sensing method based on a microfluidic device was proposed for fluid viscosity measurements. By separately delivering sample and reference fluids into the two inlets of a Y-shaped microfluidic device, an interfacial line is induced at downstream of the device. Because the interfacial width (W) between the sample and reference fluid flows was determined by their pressure ratio, the viscosity (μ) of the sample could be estimated by measuring the interfacial width. To distinguish the interfacial width of a sample, optical images of the flows at downstream of the Y-shaped microfluidic device were acquired using a smartphone. To check the measurement accuracy of the proposed method, the viscosities of glycerol mixtures were compared with those measured by a conventional viscometer. The proposed technique was applied to monitor the variations in blood and oil samples depending on storage or rancidity. We expect that this mobile sensing method based on a microfluidic device could be utilized as a viscometer with significant advantages in terms of mobility, ease-of-operation, and data management.

  17. Evaluation of Lama glama semen viscosity with a cone-plate rotational viscometer.

    PubMed

    Casaretto, C; Martínez Sarrasague, M; Giuliano, S; Rubin de Celis, E; Gambarotta, M; Carretero, I; Miragaya, M

    2012-05-01

    Llama semen is highly viscous. This characteristic is usually evaluated subjectively by measuring the thread formed when carefully pippeting a sample of semen. The aims of this study were (i) to objectively determine and analyse llama semen viscosity, (ii) to compare semen viscosity between ejaculates of the same male as well as between different males, (iii) to study the correlation between viscosity and other semen characteristics and (iv) to evaluate the effect of collagenase on semen viscosity. Semen viscosity was evaluated using a cone-plate Brookfield rotational viscometer. A non Newtonian, pseudoplastic behaviour was observed in the 45 semen samples evaluated. Rheological parameters were determined obtaining the following results (mean ± SD): apparent viscosity at 11.5 s(-1): 46.71 ± 26.8 cpoise and at 115 s(-1): 12.61 ± 4.1 cpoise; structural viscosity (K) (dyne s cm(-2)): 2.18 ± 1.4 and coefficient of consistency (n): 0.45 ± 0.1. Statistical differences were found between different ejaculates of the same male for structural viscosity and apparent viscosity at 11.5 s(-1) (P < 0.01). Correlation was found only between coefficient of consistency (n) and sperm concentration (P < 0.01). Significant differences for coefficient of consistency (n) and viscosity at 115 s(-1) were found between samples incubated with and without collagenase (P < 0.05). © 2011 Blackwell Verlag GmbH.

  18. A Rapid Capillary-Pressure Driven Micro-Channel to Demonstrate Newtonian Fluid Behavior of Zebrafish Blood at High Shear Rates.

    PubMed

    Lee, Juhyun; Chou, Tzu-Chieh; Kang, Dongyang; Kang, Hanul; Chen, Junjie; Baek, Kyung In; Wang, Wei; Ding, Yichen; Carlo, Dino Di; Tai, Yu-Chong; Hsiai, Tzung K

    2017-05-16

    Blood viscosity provides the rheological basis to elucidate shear stress underlying developmental cardiac mechanics and physiology. Zebrafish is a high throughput model for developmental biology, forward-genetics, and drug discovery. The micro-scale posed an experimental challenge to measure blood viscosity. To address this challenge, a microfluidic viscometer driven by surface tension was developed to reduce the sample volume required (3μL) for rapid (<2 min) and continuous viscosity measurement. By fitting the power-law fluid model to the travel distance of blood through the micro-channel as a function of time and channel configuration, the experimentally acquired blood viscosity was compared with a vacuum-driven capillary viscometer at high shear rates (>500 s -1 ), at which the power law exponent (n) of zebrafish blood was nearly 1 behaving as a Newtonian fluid. The measured values of whole blood from the micro-channel (4.17cP) and the vacuum method (4.22cP) at 500 s -1 were closely correlated at 27 °C. A calibration curve was established for viscosity as a function of hematocrits to predict a rise and fall in viscosity during embryonic development. Thus, our rapid capillary pressure-driven micro-channel revealed the Newtonian fluid behavior of zebrafish blood at high shear rates and the dynamic viscosity during development.

  19. Science Requirements for a Space Flight Experiment Entitled Critical Viscosity of Xenon

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.; Moldover, Michael R.

    1993-01-01

    We propose to measure in low gravity the viscosity of xenon close to its critical point. The accuracy will be sufficient to eliminate uncertainties currently associated with the analysis of l-g experiments. The measurements will provide the first direct observation of the predicted power-law divergence of viscosity in a pure fluid. The measurements will also strengthen Zeno's test of mode coupling theory by greatly increasing the reliability of the extrapolation of viscosity to low reduced temperatures. Our scientific objectives are described in more detail in one of the attached reports. The low-gravity experiment will be the final stage of a program whose completed ground-based stages are: (1) theoretical studies by one of the principal investigators (MRM) and coworkers, (2) critical viscosity measurements of binary liquid mixtures, (3) critical viscosity measurements of pure fluids in l-g, and development of a suitable vibration-insensitive viscometer. Our technical approach is described in the draft Science Requirements Document. One of us (MRM) has reviewed opportunities for critical phenomena research in low gravity. Both of us were co-principal investigators in the Thermal Equilibration Experiment in the Critical Point Facility, flown on IML-1 in 1992. From this experience, and from the technical maturity of our ground-based work, we believe our critical point viscometer is ready for development as a flight experiment.

  20. Exact-solution for cone-plate viscometry

    NASA Astrophysics Data System (ADS)

    Giacomin, A. J.; Gilbert, P. H.

    2017-11-01

    The viscosity of a Newtonian fluid is often measured by confining the fluid to the gap between a rotating cone that is perpendicular to a fixed disk. We call this experiment cone-plate viscometry. When the cone angle approaches π/2 , the viscometer gap is called narrow. The shear stress in the fluid, throughout a narrow gap, hardly departs from the shear stress exerted on the plate, and we thus call cone-plate flow nearly homogeneous. In this paper, we derive an exact solution for this slight heterogeneity, and from this, we derive the correction factors for the shear rate on the cone and plate, for the torque, and thus, for the measured Newtonian viscosity. These factors thus allow the cone-plate viscometer to be used more accurately, and with cone-angles well below π/2 . We find cone-plate flow field heterogeneity to be far slighter than previously thought. We next use our exact solution for the velocity to arrive at the exact solution for the temperature rise, due to viscous dissipation, in cone-plate flow subject to isothermal boundaries. Since Newtonian viscosity is a strong function of temperature, we expect our new exact solution for the temperature rise be useful to those measuring Newtonian viscosity, and especially so, to those using wide gaps. We include two worked examples to teach practitioners how to use our main results.

  1. Conditions of viscosity measurement for detecting irradiated peppers

    NASA Astrophysics Data System (ADS)

    Hayashi, Toru; Todoriki, Setsuko; Okadome, Hiroshi; Kohyama, Kaoru

    1995-04-01

    Viscosity of gelatinized suspensions of black and white peppers decreased depending upon dose. The viscosity was influenced by gelatinization and viscosity measurement conditions. The difference between unirradiated pepper and an irradiated one was larger at a higher pH and temperature for gelatinization. A viscosity parameter normalized with the starch content of pepper sample and the viscosity of a 5% suspension of corn starch could get rid of the influence of the conditions for viscosity measurement such as a type of viscometer, shear rate and temperature.

  2. Tape Casting of Honeywell PZT Type III Powder.

    DTIC Science & Technology

    1984-02-01

    described in Section 3.0. 2.1 Slurry Viscositv Slurry viscosity was determined at room temperature using a Brookfield rheolog model RVT-RL with small ...For the viscometer geometry used in our test (Brookfield small sample adapter SC-4, spindle 21 and chamber 13R), k’ - 0.930 and k" - 4.65M . Values...since in both cases the shear rate is developed over small distances. The x values of Table 3 seen reasonable, but may not have rigorous V practical

  3. Viscosity of Hg(0.84)Zn(0.16)Te Pseudobinary Melt

    NASA Technical Reports Server (NTRS)

    Mazuruk, K.; Su, Ching-Hua; Sha, Yi-Gao; Lehoczky, S. L.

    1996-01-01

    An oscillating-cup viscometer was developed to measure viscosity of molten HgZnTe ternary semiconductor alloys. Data were collected for the pseudobinary Hg(0.84)Zn(0.16)Te melt between 770 and 850 C. The kinematic viscosity was found to vary from approximately 1.1 to 1.4 x 10(sup -3)sq cm/s. A slow relaxation phenomena was also observed for temperatures from the melting point of 770 to approx. 800 C. Possible mechanisms for this effect are discussed.

  4. Apparatus and method for fluid analysis

    DOEpatents

    Wilson, Bary W.; Peters, Timothy J.; Shepard, Chester L.; Reeves, James H.

    2004-11-02

    The present invention is an apparatus and method for analyzing a fluid used in a machine or in an industrial process line. The apparatus has at least one meter placed proximate the machine or process line and in contact with the machine or process fluid for measuring at least one parameter related to the fluid. The at least one parameter is a standard laboratory analysis parameter. The at least one meter includes but is not limited to viscometer, element meter, optical meter, particulate meter, and combinations thereof.

  5. Liquid Viscosity and Density Measurement with Flexural-Plate-Wave Sensors

    DTIC Science & Technology

    1996-04-01

    capillary-viscometer-measured viscosity in Fig. 4. "The data from solutions of poly(ethylene glycol), having average molecular weights 3350 and 15,000...have seen similar results for the FPW-measured viscosity of salmon-sperm DNA solutions. 25 glycerol WA " PEG 3,350 H-4 . e! 2 PEG 15,000 IK- ,,,," HEC...number of aqueous solutions of the polymers poly(ethylene glycol) ( PEG ) and hydroxyethyl cellulose (HEC). The response of the FPW sensor (vertical axis

  6. Opto-mechano-fluidic viscometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Kewen, E-mail: khan56@illinois.edu; Zhu, Kaiyuan; Bahl, Gaurav, E-mail: bahl@illinois.edu

    2014-07-07

    The recent development of opto-mechano-fluidic resonators has provided—by harnessing photon radiation pressure—a microfluidics platform for the optical sensing of fluid density and bulk modulus. Here, we show that fluid viscosity can also be determined through optomechanical measurement of the vibrational noise spectrum of the resonator mechanical modes. A linear relationship between the spectral linewidth and root-viscosity is predicted and experimentally verified in the low viscosity regime. Our result is a step towards multi-frequency measurement of viscoelasticity of arbitrary fluids, without sample contamination, using highly sensitive optomechanics techniques.

  7. Method and apparatus for determining viscosity

    DOEpatents

    Chu, Benjamin; Dhadwal, Harbans S.

    1990-01-01

    A capillary viscometer is provided which includes a fiber-optic probe and a phototransistor which produces an output signal as a liquid meniscus falls through the field of view of a detecting fiber bundle. An analog circuit is employed for receiving the signal and starting or stopping a digital counter in response thereto. The circuit includes first and second differentiators and a zero detection portion for detecting zero value outputs from the second differentiator. The counter is started or stopped upon the generation of a triggering pulse at the time such zero value is detected.

  8. Rheology of composite solid propellants during motor casting

    NASA Technical Reports Server (NTRS)

    Klager, K.; Rogers, C. J.; Smith, P. L.

    1978-01-01

    Results of casting studies are reviewed so as to define the viscosity criteria insuring the fabrication of defect-free grains. The rheology of uncured propellants is analyzed showing that a realistic assessment of a propellant's flow properties must include measurement of viscosity as a function of shear stress and time after curing agent. Methods for measuring propellant viscosity are discussed, with particular attention given to the Haake-Rotovisko rotational viscometer. The effects of propellant compositional and processing variables on apparent viscosity are examined, as are results relating rheological behavior to grain defect formation during casting.

  9. Internal Waves in CVX

    NASA Technical Reports Server (NTRS)

    Berg, Robert F.

    1996-01-01

    Near the liquid-vapor critical point, density stratification supports internal gravity waves which affect 1-g viscosity measurements in the CVX (Critical Viscosity of Xenon) experiment. Two internal-wave modes were seen in the horizontal viscometer. The frequencies of the two modes had different temperature dependences: with decreasing temperature, the higher frequency increased monotonically from 0.7 to 2.8 Hz, but the lower frequency varied non-monotonically, with a maximum of 1.0 Hz at 20 mK above the critical temperature. The measured frequencies agree with independently calculated frequencies to within 15%.

  10. Viscosity of the saturated liquid phase of three fluorinated ethanes: R152a, R143a, and R125

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ripple, D.; Defibaugh, D.

    1997-03-01

    Data are reported for the viscosity of three saturated liquids over a temperature range from 255 K to 323 K. The liquids studied are the fluorinated compounds 1,1-difluoroethane (R152a), 1,1,1-trifluoroethane (R143a), and pentafluoroethane (R125). A capillary viscometer constructed of stainless steel and sapphire was used to obtain the data. The viscosity measurements have an expanded uncertainty of 2.4%. A free volume model of viscosity was used to correlate the data.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This volume contains the interim change notice for physical testing. Covered are: properties of solutions, slurries, and sludges; rheological measurement with cone/plate viscometer; % solids determination; particle size distribution by laser scanning; penetration resistance of radioactive waste; operation of differential scanning calorimeter, thermogravimetric analyzer, and high temperature DTA and DSC; sodium rod for sodium bonded fuel; filling SP-100 fuel capsules; sodium filling of BEATRIX-II type capsules; removal of alkali metals with ammonia; specific gravity of highly radioactive solutions; bulk density of radioactive granular solids; purification of Li by hot gettering/filtration; and Li filling of MOTA capsules.

  12. Surface temperatures and glassy state investigations in tribology, part 4

    NASA Technical Reports Server (NTRS)

    Bair, S. S.; Winer, W. O.

    1981-01-01

    Measurements were made of the limiting shear stress for two naphthenic oils of differing molecular weight and three blends of the lower molecular weight oil and polyalkylmethacrylate polymers of differing molecular weight. The two base oils reached the same limiting shear stress for the same temperature and pressure. This was also true for all the polymer solutions although the polymer reduced the limiting shear stress by about 15 percent. It is shown that limiting stress is more a function of material type than viscosity or molecular weight. A new falling body viscometer was constructed to operate to 230 C and 0.6 GPa. Another viscometer was constructed to extend the pressure range to 1.1 GPa. A concentrated contact simulator was developed which allows recording of the traction force while the slide-roll ratio is continuously varied and the rolling speed is maintained essentially constant by a single drive motor. The configuration is that of a crowned roller against a disk. Measurement of lubricant minimum film thickness of elliptical EHD contacts of various aspect ratios were made by optical interferometry. The data collected were used to evaluate the Hamrock and Dowson minimum film thickness model over a range of contract ellipticity ratio where the major axis of the contact ellipse was aligned both parallel and perpendicular to the direction of motion. A statistical analysis of the measured film thickness data showed that on the average the experimental data were 30 percent greater than the film thickness predicted by the model. Preliminary development of the application of a scanning infrared radiation system to a tribo-system was completed.

  13. Saliva viscosity as a potential risk factor for oral malodor.

    PubMed

    Ueno, Masayuki; Takeuchi, Susumu; Takehara, Sachiko; Kawaguchi, Yoko

    2014-11-01

    The objective of this study was to assess whether saliva viscosity, measured by a viscometer, was a predictor of oral malodor. The subjects were 617 patients who visited an oral malodor clinic. The organoleptic test (OT) was used for diagnosis of oral malodor. An oral examination assessed the numbers of teeth present and decayed teeth as well as the presence or absence of dentures. Further, periodontal pocket depths (PD), gingival bleeding, dental plaque and tongue coating were investigated. Unstimulated saliva were collected for 5 min. Saliva viscosity was measured with a viscometer. Logistic regression analysis with oral malodor status by OT as a dependent variable was performed. Possible confounders including age, gender, number of teeth present, number of decayed teeth, number of teeth with PD ≥ 4 mm, number of teeth with bleeding on probing, presence or absence of dentures, plaque index, area of tongue coating, saliva flow rate, saliva pH and saliva viscosity were used as independent variables. Saliva viscosity (p = 0.047) along with the number of teeth with PD ≥4 mm (p = 0.001), plaque index (p = 0.037) and area of tongue coating (p < 0.001) were significant variables for oral malodor. Subjects with a higher number of teeth with PD ≥ 4 mm (OR = 1.32), plaque index (OR = 2.13), area of tongue coating (OR = 3.17) and saliva viscosity (OR = 1.10) were more likely to have oral malodor compared to those with lower values. The results suggested that high saliva viscosity could be a potential risk factor for oral malodor.

  14. Critical Viscosity of Xenon

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The Critical Viscosity of Xenon Experiment (CVX-2) on the STS-107 Research 1 mission in 2002 will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. The sample cell at the heart of CVX-2 will sit inside a thermostat providing three layers of insulation. The cell itself comprises a copper body that conducts heat efficiently and smoothes out thermal variations that that would destroy the xenon's uniformity. Inside the cell, the oscillating screen viscometer element is supported between two pairs of electrodes that deflect the screen and then measure screen motion.

  15. Microgravity

    NASA Image and Video Library

    2001-01-24

    The Critical Viscosity of Xenon Experiment (CVX-2) on the STS-107 Research 1 mission in 2002 will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. The sample cell at the heart of CVX-2 will sit inside a thermostat providing three layers of insulation. The cell itself comprises a copper body that conducts heat efficiently and smoothes out thermal variations that that would destroy the xenon's uniformity. Inside the cell, the oscillating screen viscometer element is supported between two pairs of electrodes that deflect the screen and then measure screen motion.

  16. Transdermal diffusion of xenon in vitro using diffusion cells

    NASA Astrophysics Data System (ADS)

    Verkhovsky, A.; Petrov, E.

    2015-11-01

    The aim of this research was to study the diffusion rate of xenon through guinea pig skin and how viscosity of cosmetic component capryl/capric triglyceride (CCT) facilitates to deliver xenon to surface of skin patches. They were placed in Franz cell for 24 hours and diffusion rate and permeability of xenon were calculated. Thus diffusion rate was 0.031 mg/hour*cm2 and permeability was 0.003 cm/hour. Using Brookfield viscometer it was shown that viscosity of CCT decreased upon increasing xenon concentration. Obtained results can be utilized in developing of new xenon containing drugs for topical administration.

  17. Pressure-viscosity measurements for several lubricants to 5.5 x 10 to the 8th power Newtons per square meter (8 x 10 to the 4th psi) and 149 C (300 F)

    NASA Technical Reports Server (NTRS)

    Jones, W. R.; Johnson, R. L.; Winer, W. O.; Sanborn, D. M.

    1974-01-01

    A capillary viscometer was used to measure viscosity as a function of pressure, temperature, and shear stress for a number of lubricants. The conditions under which the measurements were made are specified. The results obtained for each material are analyzed. It was determined that all pressure-viscosity coefficients decreased with increasing temperature. Data from other techniques such as optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry were compared with the results obtained.

  18. Sealed Gravitational Capillary Viscometry of Dimethyl Ether and Two Next-Generation Alternative Refrigerants

    PubMed Central

    Cousins, Dylan S.; Laesecke, Arno

    2012-01-01

    The viscosities of dimethyl ether (DME, C2H6O) and of the fluorinated propene isomers 2,3,3,3-tetrafluoroprop-1-ene (R1234yf, C3H2F4) and trans-1,3,3,3-tetrafluoropropene (R1234ze(E)) were measured in a combined temperature range from 242 K to 350 K at saturated liquid conditions. The instrument was a sealed gravitational capillary viscometer developed at NIST for volatile liquids. Calibration and adjustment of the instrument constant were conducted with n-pentane. The repeatability of the measurements was found to be approximately 1.5 %, leading to a temperature-dependent estimated combined standard uncertainty of the experimental data between 5.7 % at 242 K for dimethyl ether and 2.6 % at 340 K for R1234yf. The measurements were supplemented by ab initio calculations of the molecular size, shape, and charge distributions of the measured compounds. The viscosity results for dimethyl ether were compared with literature data. One other data set measured with a sealed capillary viscometer and exceeding the present results by up to 7 % could be reconciled by applying the vapor buoyancy correction. Then, all data agreed within the estimated uncertainty of the present results. Viscosities for the fluorinated propene isomers deviate up to 4 % from values predicted with the NIST extended corresponding-states model. The viscosities of the two isomers do not scale with their dipole moments. While the measured viscosity of R1234ze(E) with the lower dipole moment is close to that of R134a, the refrigerant to be replaced, that of R1234yf with the higher dipole moment is up to 25 % lower. The viscosity of dimethyl ether is compared with those of water and methanol. PMID:26900526

  19. Survismeter, 2-IN-1 for Viscosity and Surface Tension Measurement, AN Excellent Invention for Industrial Proliferation of Surface Forces in Liquids

    NASA Astrophysics Data System (ADS)

    Singh, Man

    Viscosities (η, N s m-2) and surface tensions (γ, N m-1) of methanol, ethanol, glycerol, ethyl acetate, n-hexane, diethyl ether, chloroform, benzene, carbon tetrachloride (CCl4), tetrahydrofuran (THF), dimethylformamide (DMF), dimethylsulfoxide (DMSO), acetonitrile, and formic acid have been measured with survismeter and compared with the data obtained by Ubbehold viscometer and stalagmometer, respectively. The ±1.1 × 10-5 N s m-2 and ±1.3 × 10-6 N m-1 deviations are noted in the data, in fact literature data of surface tension and viscosity are available to 2nd and 3rd place of decimals, respectively, while the survismeter measures them to 3rd and 4th place of decimals, respectively. The survismeter is 2-in-1 for viscosity and surface tension measurements together with high accuracies several times better than those of the separately measured data. Viscosities and surface tensions of aqueous DMSO, THF, DMF, and acetonitrile from 0.01 to 0.20 mol kg-1 and mannitol from 0.005 to 0.02 mol kg-1 have been measured with survismeter with ±1.2 × 10-5 N s m-2 and ±1.3 × 10-6 N m-1 deviations, respectively. The data are used for friccohesity and dipole moment determination, the lower viscosities, surface tension, and friccohesity values are noted for mannitol as compared to DMSO, THF, DMF, and acetonitrile solutions. The weaker molecular interactions are noted for mannitol. As compared to viscometer and stalagmometer individually, it is inexpensive and minimizes 2/3rd of consumables, human efforts, and infrastructure with 10 times better accuracies.

  20. Detection of some irradiated spices on the basis of radiation induced damage of starch

    NASA Astrophysics Data System (ADS)

    Farkas, J.; Sharif, M. M.; Koncz, Á.

    Untreated and irradiated samples of spices were suspended in water, alkalized, and after heat-gelatinization, the apparent viscosity was determined by a rotational viscometer. Several spices, i.e. white pepper, black pepper, nutmeg and ginger showed considerable loss of viscosity as a function of γ-radiation dose in the dose range required for microbial decontamination of natural spices. Less promising results were obtained with spices such as allspice, garlic powder, and onion powder forming low-viscosity heat-treated suspensions even when unirradiated viscometric studies were also performed with a number of pepper samples of various origin to estimate the "natural" variation of rheological properties. Irradiation and storage studies were performed with ground black pepper samples of moisture contents in equilibrium with air of 25%, 50% and 75% R.H., respectively, either untreated or irradiated with 4, 8, 16 or 32 kGy, to study the effect of equilibrium relative humidity and storage time on detectability of radiation treatment. During the entire storage period of 100 days, statistically significant differences of the apparent viscosities of heat-gelatinized suspensions remained detectable between untreated samples and those irradiated with 8 kGy or higher doses. The apparent viscosity of high-moisture (75% E.R.H.) untreated samples was decreasing during long-term storage. Differences between viscosities of untreated and irradiated samples were enlarged when measured at elevated temperatures such as 50°C in the rotational viscometer, or in the boiling-water bath of a falling number apparatus. Other analytical indices such as onset and peak temperatures of gelatinization endotherms by DSC (damaged starch content), by colorimetry, reducing sugar content, alcohol-induced turbidity of hot water extracts of pepper samples, have been changed less dramatically by irradiation than the apparent viscosity of the gelatinized suspensions

  1. Measurement of viscosity and elasticity of lubricants at high pressures

    NASA Technical Reports Server (NTRS)

    Rein, R. G., Jr.; Charng, T. T.; Sliepcevich, C. M.; Ewbank, W. J.

    1975-01-01

    The oscillating quartz crystal viscometer has been used to investigate possible viscoelastic behavior in synthetic lubricating fluids and to obtain viscosity-pressure-temperature data for these fluids at temperatures to 300 F and pressures to 40,000 psig. The effect of pressure and temperature on the density of the test fluids was measured concurrently with the viscosity measurements. Viscoelastic behavior of one fluid, di-(2-ethylhexyl) sebacate, was observed over a range of pressures. These data were used to compute the reduced shear elastic (storage) modulus and reduced loss modulus for this fluid at atmospheric pressure and 100 F as functions of reduced frequency.

  2. Transport properties of nonelectrolyte mixtures. IX. Viscosity coefficients for acetonitrile and for three mixtures of toluene+acetonitrile from 25 to 100°c at pressures up to 500 MPa

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Awan, M. A.; Glen, N. F.; Isdale, J. D.

    1991-05-01

    A two-coil self-centering falling-body viscometer has been used to measure viscosity coefficients for acetonitrile and three binary mixtures of toluene+ acetonitrile at 25, 50, 75, and 100°C and pressures up to 500 MPa. The results for acetonitrile can be interpreted by an approach based on hard-sphere theory, with a roughness factor of 1.46. The binary-mixture data are well represented by the Grunberg and Nissan equation with a mixing parameter which is pressure and temperature dependent but composition independent.

  3. Transport properties of nonelectrolyte liquid mixtures—VI. Viscosimetric study of binary mixtures of hexafluorobenzene with aromatic hydrocarbons

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Robertson, J.

    1985-01-01

    Viscosity coefficients for binary mixtures of hexafluorobenzene with benzene, toluene, para-xylene, and mesitylene have been measured along the saturation line at temperatures from 15 to 120°C using specially designed capillary viscometers. Densities were measured using a pyknometer and volume-change apparatus. Deviations of the viscosities from a rectilinear dependence on mole fraction are consistent with enhanced interactions between unlike species, which increase with increasing number of methyl groups on the aromatic hydrocarbon and decrease with increasing temperature. The application of the Grunberg and Nissan equation, the Hildebrand equation, and energy of activation theories to these results is examined.

  4. Dynamic viscoelasticity measurement under alternative torque using electromagnetically spinning method with quadruple electromagnets.

    PubMed

    Matsuura, Yusuke; Hirano, Taichi; Sakai, Keiji

    2017-07-01

    In this study, we developed a novel type of rheological measurement system. Here, a spherical probe is driven to rotate periodically by applying torques using quadruple electromagnets in a noncontact manner. Moreover, this system is an enhancement of our electromagnetically spinning (EMS) viscometer, which is widely used for measuring rheological flow curves in various industrial fields. The quadruple EMS method provides the frequency spectrum of viscoelasticity, in addition to shear viscosity, in a steady flow by switching the operation modes of the driving torque. We show the results obtained for Newtonian fluids and viscoelastic materials and demonstrate the validity of the system.

  5. Transport properties of alumina nanofluids.

    PubMed

    Wong, Kau-Fui Vincent; Kurma, Tarun

    2008-08-27

    Recent studies have showed that nanofluids have significantly greater thermal conductivity compared to their base fluids. Large surface area to volume ratio and certain effects of Brownian motion of nanoparticles are believed to be the main factors for the significant increase in the thermal conductivity of nanofluids. In this paper all three transport properties, namely thermal conductivity, electrical conductivity and viscosity, were studied for alumina nanofluid (aluminum oxide nanoparticles in water). Experiments were performed both as a function of volumetric concentration (3-8%) and temperature (2-50 °C). Alumina nanoparticles with a mean diameter of 36 nm were dispersed in water. The effect of particle size was not studied. The transient hot wire method as described by Nagaska and Nagashima for electrically conducting fluids was used to test the thermal conductivity. In this work, an insulated platinum wire of 0.003 inch diameter was used. Initial calibration was performed using de-ionized water and the resulting data was within 2.5% of standard thermal conductivity values for water. The thermal conductivity of alumina nanofluid increased with both increase in temperature and concentration. A maximum thermal conductivity of 0.7351 W m(-1) K(-1) was recorded for an 8.47% volume concentration of alumina nanoparticles at 46.6 °C. The effective thermal conductivity at this concentration and temperature was observed to be 1.1501, which translates to an increase in thermal conductivity by 22% when compared to water at room temperature. Alumina being a good conductor of electricity, alumina nanofluid displays an increasing trend in electrical conductivity as volumetric concentration increases. A microprocessor-based conductivity/TDS meter was used to perform the electrical conductivity experiments. After carefully calibrating the conductivity meter's glass probe with platinum tip, using a standard potassium chloride solution, readings were taken at various volumetric concentrations. A 3457.1% increase in the electrical conductivity was measured for a small 1.44% volumetric concentration of alumina nanoparticles in water. The highest value of electrical conductivity, 314 µS cm(-1), was recorded for a volumetric concentration of 8.47%. In the determination of the kinematic viscosity of alumina nanofluid, a standard kinematic viscometer with constant temperature bath was used. Calibrated capillary viscometers were used to measure flow under gravity at precisely controlled temperatures. The capillary viscometers were calibrated with de-ionized water at different temperatures, and the resulting kinematic viscosity values were found to be within 3% of the standard published values. An increase of 35.5% in the kinematic viscosity was observed for an 8.47% volumetric concentration of alumina nanoparticles in water. The maximum kinematic viscosity of alumina nanofluid, 2.901 42 mm(2) s(-1), was obtained at 0 °C for an 8.47% volumetric concentration of alumina nanoparticles. The experimental results of the present work will help researchers arrive at better theoretical models.

  6. Fitting mathematical models to describe the rheological behaviour of chocolate pastes

    NASA Astrophysics Data System (ADS)

    Barbosa, Carla; Diogo, Filipa; Alves, M. Rui

    2016-06-01

    The flow behavior is of utmost importance for the chocolate industry. The objective of this work was to study two mathematical models, Casson and Windhab models that can be used to fit chocolate rheological data and evaluate which better infers or previews the rheological behaviour of different chocolate pastes. Rheological properties (viscosity, shear stress and shear rates) were obtained with a rotational viscometer equipped with a concentric cylinder. The chocolate samples were white chocolate and chocolate with varying percentages in cacao (55%, 70% and 83%). The results showed that the Windhab model was the best to describe the flow behaviour of all the studied samples with higher determination coefficients (r2 > 0.9).

  7. Rheological behaviour of egg white and egg yolk from different poultry specimen

    NASA Astrophysics Data System (ADS)

    Kumbár, V.; Nedomová, Š.; Votava, J.; Buchar, J.

    2017-01-01

    The main goal of this study is differences in rheological behaviour of hen (ISA BROWN), goose (Anser anser f. domestica) and Japanese quail (Coturnix japonica) egg white and egg yolk. The rheological behaviour of egg white and egg yolk was studied using a concentric cylinder viscometer. Rheological behaviour was pseudoplastic and flow curves were fitted by the Herschel-Bulkley model and Ostwald-de Waele model with high values of coeficients of determination R2. The meaning of rheological parameters on friction factors during flow of egg white and egg yolk in real tube has been shown. Preliminary information on time-dependent behaviour of tested liquids has been also obtained.

  8. Coal desulfurization during the combustion of coal/oil/water emulsions: an economic alternative clean liquid fuel. Interim report, October 1978-November 15, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooher, J. P.

    1979-11-15

    The rheological and combustion properties of coal/water/oil mixtures have been investigated. In addition the use of alkaline additives to remove the sulfur oxide gases has been studied. Results on stability and pumpability indicate that mixtures of 50% by weight of coal and stoichiometric concentrations of alkaline absorbents are pumpable. Correlation between viscometer data and pumping data follows a power law behavior for these mixtures. Thermal efficiencies are about the same as for pure oil. Combustion efficiencies are approximately 97%. It is possible to remove in a small scale combustion from 50 to 80% of the sulfur dioxide gases.

  9. Viscosity Measurements and Correlation of the Squalane + CO2 Mixture

    NASA Astrophysics Data System (ADS)

    Tomida, D.; Kumagai, A.; Yokoyama, C.

    2007-02-01

    Experimental results for the viscosity of squalane + CO2 mixtures are reported. The viscosities were measured using a rolling ball viscometer. The experimental temperatures were 293.15, 313.15, 333.15, and 353.15 K, and pressures were 10.0, 15.0, and 20.0 MPa. The CO2 mole fraction of the mixtures varied from 0 to 0.417. The experimental uncertainties in viscosity were estimated to be within ±3.0%. The viscosity of the mixtures decreased with an increase in the CO2 mole fraction. The experimental data were compared with predictions from the Grunberg-Nissan and McAllister equations, which correlated the experimental data with maximum deviations of 10 and 8.7%, respectively.

  10. Measurement of the microscopic viscosities of microfluids with a dynamic optical tweezers system

    NASA Astrophysics Data System (ADS)

    Zhang, Yuquan; Wu, Xiaojing; Wang, Yijia; Zhu, Siwei; Gao, Bruce Z.; Yuan, X.-C.

    2014-06-01

    Viscosity coefficients of microfluids—Newtonian and non-Newtonian—were explored through the rotational motion of a particle trapped by optical tweezers in a microflute. Unlike conventional methods based on viscometers, our microfluidic system employs samples of less than 30 μl to complete a measurement. Viscosity coefficients of ethanol and fetal bovine serum, as typical examples of Newtonian and non-Newtonian fluids, were obtained experimentally, and found to be in excellent agreement with theoretical predictions. Additionally, a practical application to a DNA solution with incremental ethidium bromide content was employed and the results are consistent with clinical data, indicating that our system provides a potentially important complementary tool for use in such biological and medical applications.

  11. Transport properties of nonelectrolyte liquid mixtures. VIII. Viscosity coefficients for toluene and for three mixtures of toluene + hexane from 25 to 100°C at pressures up to 500 MPa

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Awan, M. A.; Glen, N. F.; Isdale, J. D.

    1991-03-01

    Viscosity coefficients measured using a two-coil self-centering falling-body viscometer are reported for toluene and three binary mixtures of toluene + n-hexane at 25, 50, 75, and 100°C at pressures up to 500 MPa. The data for a given composition at different temperatures and pressures are correlated very satisfactorily by a plot of reduced viscosity η * versus log V', where V'= V· V 0(TR)/V0(T) and V 0 represents a characteristic volume. The binary mixture data are well represented by the Grunberg and Nissan equation with a mixing parameter which is pressure dependent but composition and temperature independent.

  12. Viscosity of Industrially Important Zn-Al Alloys Part II: Alloys with Higher Contents of Al and Si

    NASA Astrophysics Data System (ADS)

    Nunes, V. M. B.; Queirós, C. S. G. P.; Lourenço, M. J. V.; Santos, F. J. V.; Nieto de Castro, C. A.

    2018-05-01

    The viscosity of Zn-Al alloys melts, with industrial interest, was measured for temperatures between 693 K and 915 K, with an oscillating cup viscometer, and estimated expanded uncertainties between 3 and 5 %, depending on the alloy. The influence of minor components, such as Si, Mg and Ce + La, on the viscosity of the alloys is discussed. An increase in the amount of Mg triggers complex melt/solidification processes while the addition of Ce and La renders alloys viscosity almost temperature independent. Furthermore, increases in Al and Si contents decrease melts viscosity and lead to an Arrhenius type behavior. This paper complements a previous study describing the viscosity of Zn-Al alloys with quasi-eutectic compositions.

  13. Mucolytic Activity Test of Shallot Extract (Allium Ascalonicum L) by in Vitro

    NASA Astrophysics Data System (ADS)

    Deswati, D. A.; Dhina, M. A.; Mubaroq, S. R.

    2018-01-01

    This paper aims to explain the results of research on the mucolytic activity of shallot extract is proportional to 0.2% N-Acetylcysteine. Shallot (Allium ascalonicum L.) is efficacious for treating cough. This research was conducted by examining the mucolytic activity of shallot extract made with various dose concentration 5%, 10%, 15%, 20%, and 25%. The mucolytic activity test was performed in vitro based on the decrease in the viscosity of the egg whites by using the Brookfield viscometer. The results showed that shallot extract with dose concentration of 5%, 10%, 15%, 20%, 25% had mucolytic activity by decreasing the viscosity of egg white solution. The effective concentration almost equal to 0.2% N-Acetylcysteine is at 25% concentration.

  14. Thermo-acoustical molecular interaction study in binary mixtures of glycerol and ethylene glycol

    NASA Astrophysics Data System (ADS)

    Kaur, Kirandeep; Juglan, K. C.; Kumar, Harsh

    2017-07-01

    Ultrasonic velocity, density and viscosity are measured over the entire composition range for binary liquid mixtures of glycerol (CH2OH-CHOH-CH2OH) and ethylene glycol (HOCH2CH2OH) at different temperatures and constant frequency of 2MHz using ultrasonic interferometer, specific gravity bottle and viscometer respectively. Measured experimental values are used to obtained various acoustical parameters such as adiabatic compressibility, acoustic impedance, intermolecular free length, relaxation time, ultrasonic attenuation, effective molar weight, free volume, available volume, molar volume, Wada's constant, Rao's constant, Vander Waal's constant, internal pressure, Gibb's free energy and enthalpy. The variation in acoustical parameters are interpreted in terms of molecular interactions between the components of molecules of binary liquid mixtures.

  15. Effects of the kinematic viscosity and surface tension on the bubble take-off period in a catalase-hydrogen peroxide system.

    PubMed

    Sasaki, Satoshi; Iida, Yoshinori

    2009-06-01

    The effect of kinematic viscosity and surface tension of the solution was investigated by adding catalase, glucose oxidase, or glucose on the bubble movement in a catalase-hydrogen peroxide system. The kinematic viscosity was measured using a Cannon-Fenske kinematic viscometer. The surface tension of the solution was measured by the Wilhelmy method using a self-made apparatus. The effects of the hole diameter/cell wall thickness, catalase concentration, glucose concentration, and glucose oxidase concentration on the kinematic viscosity, surface tension, and bubble take-off period were investigated. With our system, the effects of the changes in the solution materiality on the bubble take-off period were proven to be very small in comparison to the change in the oxygen-producing rate.

  16. Viscosities of nonelectrolyte liquid mixtures. II. Binary and quaternary systems of some n-alkanes

    NASA Astrophysics Data System (ADS)

    Wakefield, D. L.; Marsh, K. N.; Zwolinski, B. J.

    1988-01-01

    This paper is the second in a series of viscosity and density studies on multicomponent mixtures of n-alkanes from 303 to 338 K. Reported here are the results of binary mixtures of n-tetracosane + n-octane as well as quaternary mixtures of n-tetracosane + n-octane + n-decane + n-hexane at 318.16, 328.16, and 338.16 K. Viscosities were determined using a standard U-tube Ostwald viscometer, and densities were determined using a flask-type pycnometer. Empirical relations tested include the Grunberg and Nissan equation and the method of corresponding states. In addition, comparisons were made regarding the behavior of this quaternary system and homologous binary mixtures of n-hexadecane + n-octane and n-tetracosane + n-octane at the same temperatures.

  17. Characterizing optical polishing pitch

    NASA Astrophysics Data System (ADS)

    Varshneya, Rupal; DeGroote, Jessica E.; Gregg, Leslie L.; Jacobs, Stephen D.

    2003-05-01

    Characterization data for five experimental optical polishing pitch products were compared to those for corresponding standard commercial optical polishing pitches. The experimental pitches were tested for three physical properties: hardness, viscosity at 90°C, and softening point. A Shore A Durometer test was used to measure hardness. Viscosity data were collected using a Stony Brook Scientific falling needle viscometer. Softening point was determined using the ASTM D3104-97 method. Results demonstrate that the softest and the hardest batches of the experimental grades of optical pitch are comparable to the industry-accepted standards, while the other grades of pitch are not. The experimental methodology followed in this research may allow opticians to rapidly compare different brands of pitch to help identify batch-to-batch differences and control pitch quality before use.

  18. Characterizing optical polishing pitch

    NASA Astrophysics Data System (ADS)

    Varshneya, Rupal

    2003-05-01

    Characterization data for five experimental optical polishing pitch products were compared to those for corresponding standard commercial optical polishing pitches. The experimental pitches were tested for three physical properties: hardness, viscosity at 90°C, and softening point. A Shore A Durometerl test was used to measure hardness. Viscosity data were collected using a Stony Brook Scientific' falling needle viscometer. Softening point was determined using the ASTM D3104-97 method. Results demonstrate that the softest and the hardest batches of the experimental grades of optical pitch are comparable to the industry-accepted standards, while the other grades of pitch are not. The experimental methodology followed in this research may allow opticians to rapidly compare different brands of pitch to help identify batch- to- batch differences and control pitch quality before use.

  19. The Rheology of a Three Component System: COAL/WATER/#4 Oil Emulsions.

    NASA Astrophysics Data System (ADS)

    Gilmartin, Barbara Jean

    The purpose of this investigation was to study the rheology of a three component system, coal/water/#4 oil emulsions (COW), in which the third component, water, was present in a significant concentration, and to determine the applicability of existing theories from suspension rheology to the three component system studied. In a coal/water/oil emulsion, free coal particles adhere to the surface of the water droplets, preventing their coagulation, while the larger coal particles reside in the matrix of stabilized water droplets. The use of liquid fuels containing coal is a means of utilizing our nation's coal reserves while conserving oil. These fuels can be burned in conventional oil-fired furnaces. In this investigation, a high sulfur, high ash, bituminous coal was used, along with a heavy #4 oil to prepare the emulsions. The coal was ground to a log-normal distribution with an average particle size of 62 microns. A Haake RV3 concentric cylinder viscometer, with a ribbed measuring system, was used to determine the viscosity of the emulsions. A physical pendulum settling device measured the shift in center of mass of the COW as a function of time. The flow behavior of the fuel in pipes was also tested. In interpreting the data from the viscometer and the pipe flow experiments, a power law analysis was used in the region from 30 s('-1) to 200 s('-1). Extrapolation methods were used to obtain the low and high shear behavior of the emulsions. In the shear rate region found in boiler feed systems, COW are shear thinning with a flow behavior index of 0.7. The temperature dependent characteristic of the emulsions studied were similar and followed an Arrhenius type relationship. The viscosity of the COW decreases with increasing coal average particle size and is also a function of the width of the size distribution used. The type of coal used strongly influences the rheology of the fuel. The volatile content and the atomic oxygen to nitrogen ratio of the coal are the most predictive factors in terms of the variation in viscosity of the emulsion with coal type. The viscosity of the oil used is linearly related to the viscosity of the COW. The relative viscosity - concentration relationship for the emulsions was evaluated by an equation developed by Quemada for use in blood rheology: (eta)(,r) = (1 - (phi)/(phi)(,max))('-2). The best fit of the data to the equation was found when the coal plus water concentration was used for (phi). The maximum packing fraction increased with increasing shear rate, reflecting a breaking up of the agglomerates in the system. By using the relative packing fraction of the coal plus oil concentration, the relative viscosity of the emulsions tested at the three shear rates evaluted can be fit to the Quemada relative viscosity equation. In the pipe flow tests, the emulsions showed little time-dependent behavior, however they did exhibit a well effect. A fair correlation was obtained between pipe flow behavior and the results obtained in the viscometer. Coal/water/#4 oil emulsions behave as coal and water in oil systems and can be successfully modeled using theories from suspension rheology.

  20. Viscoelastic properties of the small intestinal and caecal contents of the chicken.

    PubMed

    Takahashi, T; Goto, M; Sakata, T

    2004-06-01

    We measured the coefficients of viscosity, shear rates and shear stresses of chicken small intestinal and caecal contents, including solid particles, using a tube-flow viscometer. The coefficients of viscosity of chicken small intestinal and caecal contents were correlated negatively with their shear rates, a characteristic typical of non-Newtonian fluids. The coefficient of viscosity of the small intestinal contents was lower than that of the caecal contents at a shear rate of 1 s(-1). Chicken caecal contents were more viscous than pig caecal contents. The exponential relationship between shear stress and shear rate showed that chicken small intestinal and caecal contents had an apparent Herschel-Bulkley fluid nature. These results indicate that solid particles, including uric acid crystals, are mainly responsible for the viscosity of the digesta in the chicken.

  1. Drag reducing properties of microalgal exopolymers.

    PubMed

    Ramus, J; Kenney, B E; Shaughnessy, E J

    1989-01-25

    Dilute aqueous solutions of polymers released by marine phytoplankton (microalgae) were shown to effectively reduce drag in capillary pipe flow. Tests were performed in a capillary turbulent flow viscometer which extruded small samples under high pressures. In all, 22 species were screened, and the products of one chlorophyte and four rhodophyte species proved especially effective. The viscoelastic polymers produced by these species delayed the transition from laminar to turbulent flow to significantly higher Re. In general, polymeric regime segments come off the maximum drag reduction asymptote at characteristic retro-onset points, and come to lie approximately parallel to, but displaced upwards from the Prandtl-von Karman line. The delay to transition was shown to be dependent on additive polymer concentration, capillary diameter, and temperature. Ionic concentration, ionic composition, or pH had little effect on drag reducing properties.

  2. Transport properties of nonelectrolyte liquid mixtures—VII. Viscosity coefficients for isooctane and for equimolar mixtures of isooctane + n-octane and isooctane + n-dodecane from 25 to 100°C at pressures up to 500 MPa or to the freezing pressure

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Glen, N. F.; Isdale, J. D.

    1985-05-01

    Changes in the high-pressure self-centering falling-body viscometer system, and the new automated data logging system, are described. Viscosity coefficient measurements made with an estimated accuracy of ± 2 % are reported for isooctane and for equimolar mixtures of isooctane + n-octane and isooctane + n-dodecane at 25, 50, 75, and 100°C at pressures up to 500 MPa or to the freezing pressure. The pressure dependence of the results is found to be represented equally well by the recent equation of Makita and by a free-volume form of equation. The Grunberg and Nissan equation gives a good fit to the mixture viscosity coefficient data.

  3. Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.; Hartl, J. H.

    1980-01-01

    Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

  4. High intensity 5 eV O-atom exposure facility for material degradation studies

    NASA Technical Reports Server (NTRS)

    Cross, J. B.; Spangler, L. H.; Hoffbauer, M. A.; Archuleta, F. A.; Leger, Lubert; Visentine, James; Hunton, Don E.; Cross, J. B.

    1986-01-01

    An atomic oxygen exposure facility was developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in low Earth orbit. The studies that are being undertaken will provide: (1) absolute reaction cross sections for the engineering design problems, (2) formulations of reaction mechanisms for use in the selection of suitable existing materials and the design of new more resistant ones, and (3) the calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in low Earth orbit to ground based investigations. The facility consists of a CW laser sustained discharge source of O-atoms, an atomic beam formation and diagnostics system, a spinning rotor viscometer, and provision for using the system for calibration of actual flight instruments.

  5. The measurement and estimation of the low-pressure gas viscosity of the replacement ternary blend halo-alkane refrigerant MP-39

    NASA Astrophysics Data System (ADS)

    Matthews, G. P.; Dowdell, D. C.; Wells, I.

    1997-07-01

    A capillary gas flow viscometer has been used to measure the shear viscosity of the ternary blend refrigerant MP-39 (52% chlorodifluoromethane; 15% 1,1-difluoroethane and 33% 2-chloro-1,1,1,2-tetrafluoroethane) in the gaseous phase at pressures up to 0.1 MPa, relative to a nitrogen standard in the temperature range 308 - 403 K. Recorded flow times were corrected for small temperature drifts, kinetic energy effects, gas imperfection effects and slip flow. The pressure and temperature conditions were chosen such that curved pipe flow and turbulence effects were negligible. The resulting viscosities agree to within 3.1% with predictions based on the semi-empirical equations of Wilke and of Herning and Zipperer. Potential parameters for the three mixture components are presented, but the incompatibility of these parameters precludes their use in the more sophisticated Brokaw approximation.

  6. The viscosity of the refrigerant 1,1-difluoroethane along the saturation line

    NASA Astrophysics Data System (ADS)

    van der Gulik, P. S.

    1993-07-01

    The viscosity coefficient of the refrigerant R152a (1,1-difluoroethane) has been measured along the saturation line both in the saturated liquid and in the saturated vapor. The data have been obtained every 10 K from 243 up to 393 K by means of a vibrating-wire viscometer using the free damped oscillation method. The density along the saturation line was calculated from the equation of state given by Tamatsu et al. with application of the saturated vapor-pressure correlation given by Higashi et al. An interesting result is that in the neighborhood of the critical point, the kinematic viscosity of the saturated liquid seems to coincide with that of the saturated vapor. The results for the saturated liquid are in satisfying agreement with those of Kumagai and Takahashi and of Phillips and Murphy. A comparison of the saturatedvaport data with the unsaturated-vapor data of Takahashi et al. shows some discrepancies.

  7. Viscoplasticity of simulated high-level radioactive waste glass containing platinum group metal particles

    NASA Astrophysics Data System (ADS)

    Uruga, Kazuyoshi; Usami, Tsuyoshi; Tsukada, Takeshi; Komamine, Satoshi; Ochi, Eiji

    2014-09-01

    The shear rate dependency of the viscosity of three simulated high-level radioactive waste glasses containing 0, 1.2 and 4.5 wt% platinum group metals (PGMs) was examined at a temperature range of 1173-1473 K by a rotating viscometer. Shear stress when the shear rate equals zero, i.e. yield stress, was also measured by capillary method. The viscosity of the glass containing no PGM was shear rate-independent Newtonian fluid. On the other hand, the apparent viscosity of the glasses containing PGMs increased with decreasing shear rate, and nonzero amount of yield stresses were detected from both glasses. The viscosity and yield stress of the glass containing 4.5 wt% PGMs was roughly one to two orders of magnitude greater than the glass containing 1.2 wt% PGMs. These viscoplastic properties were numerically expressed by Casson equation.

  8. Performance of magnetorheological elastomer based green epoxidized natural rubber/sucrose acetate isobutyrate hybrid matrix

    NASA Astrophysics Data System (ADS)

    Khairi, Muntaz Hana Ahmad; Amri Mazlan, Saiful; Aziz, Siti Aishah Abdul; Ubaidillah; Tan Shilan, Salihah

    2018-04-01

    This study introduces a sucrose acetate isobutyrate (SAIB) as a novel additive of magnetorheological elastomers (MREs). The MREs utilized an epoxidized natural rubber (ENR) as the matrix and carbonyl iron particles (CIPs) as their filler. The CIPs were fixed at 60 wt%. The viscosity of the compound was observed using a viscometer. Meanwhile, the microstructures were observed by using field emission scanning electron microscope (FESEM). Rheological properties regarding shear storage modulus were measured by using a rheometer (MCR 302, Anton Paar). The experimental results demonstrated that the MREs-based ENR/SAIB had a decrement in their viscosity by 40% reduction. Moreover, the magnetorheological (MR) effect increased by 23% as the increment of magnetic fields. The morphological photograph showed that the CIPs embedded well within the matrix. The fabricated MREs samples were strain dependent, where all MREs samples exhibit the deteriorating trend when increasing the strain amplitude.

  9. Experiment on aggregation of red cells under microgravity on STS 51-C

    NASA Astrophysics Data System (ADS)

    Dintenfass, L.; Osman, P.; Maguire, B.; Jedrzejczyk, H.

    Kinetics and morphology of aggregation of red cells were studied using automatic slit-capillary photo-viscometers, one situated on the middeck of the space shuttle `Discovery', and the other in the ground laboratory at KSC. Experiments were run simultaneously, blood samples being adjusted to haematocrit of 0.30 using native plasma, at temp. of 25°C, and anticoagulated by EDTA. Donors included patients with myocardial infarction, insulin-dependent diabetes, hyperlipidaemia and hypertension. Macro and microphotographs were obtained during flow and statis. There was a striking difference in the morphology of aggregates formed in space and on the ground. Aggregates formed under zero gravity showed rouleaux formation, while the same blood samples showed severe clumping on the ground, in all patients blood. Normal blood showed rouleaux on the ground, but a random swarm-like pattern in space. The shape of the red cells remained normal under zero gravity.

  10. The determination of viscosity at liquid mixtures - Comparison of approaches

    NASA Astrophysics Data System (ADS)

    Michal, Schmirler; Hana, Netřebská; Jan, Kolínský

    2017-09-01

    The research of flow field parameters for non-stationary flow of non-Newtonian fluids carried out at the Institute of Fluid Mechanics and Thermodynamics of CTU showed the need for knowledge of determination of the resulting viscosity of a mixture of several liquids. There are several sources for determining viscosity of mixtures. It is possible either to find theoretical relations in the literature or use technical tables based on experimentally measured data. This article focuses on comparing these approaches with an experiment. The experiment was performed by a Rheotest RN 4.1 rotating viscometer produced by the company RHEOTEST Medingen. The research was carried out using a solution of glycerol and water. The research has shown great differences in results in different approaches for determining the viscosity of the liquid mixtures. The result of this paper is to determine the method of viscosity calculation that is closest to the experimental data.

  11. Effect of the different chain transfer agents on molecular weight and optical properties of poly(methyl methacrylate)

    NASA Astrophysics Data System (ADS)

    Çetinkaya, Onur; Demirci, Gökhan; Mergo, Paweł

    2017-08-01

    Investigation of molecular weight and optical properties of poly(methyl metacrylate) (PMMA) polymerized in house with different chain transfer agents was studied. Isopropyl alcohol (IPA), n-butyl mercaptan (nBMC) and pentamethyl disilane (PMDS) were used as chain transfer agents. The molecular weight (Mw) of PMMA samples were measured by Ostwald viscometer. Mw of bulk polymer samples were decreased with increase the concentration of chain transfer agents (CTA). Since reactivity of used CTAs is not same, molecular weights of samples which were produced with different type of CTA but same concentration of CTA was varied. Higher concentration of n-BMC showed higher scattering. Transmission of samples could not be correlated with different concentration of CTA. Refractive index of samples was not affected by concentration of CTA nevertheless higher molecular weight of CTA showed higher refractive index.

  12. Transport properties of nonelectrolyte liquid mixtures—IV. Viscosity coefficients for benzene, perdeuterobenzene, hexafluorobenzene, and an equimolar mixture of benzene + hexafluorobenzene from 25 to 100°c at pressures up to the freezing pressure

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Robertson, J.; Isdale, J. D.

    1981-09-01

    Viscosity coefficient measurements made with an estimated accuracy of ±2% using a self-centering falling body viscometer are reported for benzene, perdeuterobenzene, hexafluorobenzene and an equimolar mixture of benzene + hexafluorobenzene at 25, 50, 75 and 100°C at pressures up to the freezing pressure. The data for each liquid at different temperatures and pressures are correlated very satisfactorily by a graphical method based on plots of 9.118×107 ηV 2/3/(MRT)1/2 versus logV, and are reproduced to within the experimental uncertainty by a free-volume form of equation. Application of the empirical Grunberg and Nissan equation to the mixture viscosity coefficient data shows that the characteristic constant G is practically temperature- and pressure-independent for this system.

  13. Palm oil based nanofluids for enhancing heat transfer and rheological properties

    NASA Astrophysics Data System (ADS)

    Hussein, A. M.; Lingenthiran; Kadirgamma, K.; Noor, M. M.; Aik, L. K.

    2018-04-01

    Colloidal suspensions of nanomaterials size not more than 100 nm in basefluid are defined as nanofluids. The thermal and rheological properties study of oil based nanofluid is conducted to develop stable transformers palm oil based nanofluid. This paper describes the analysis techniques to determine the enhancement of thermal properties of nanofluids. Titanium dioxide (TiO2) has dispersed in the palm oil to prepare nanofluids with volume concentration (0.01-0.09) percentage. Both thermal conductivity and viscosity of nanofluid have measured by using the hot wire method and viscometer equipment respectively. Results indicate that the stable nanofluids improve the thermal properties as compared to palm oil. Results showed that the friction factor decreases as the Reynolds number increases and increases as the volume concentration increases. Additionally, the Nusselt number increases as the Reynolds number and volume concentration of the nanofluid increases.

  14. Viscosity of Common Seed and Vegetable Oils

    NASA Astrophysics Data System (ADS)

    Wes Fountain, C.; Jennings, Jeanne; McKie, Cheryl K.; Oakman, Patrice; Fetterolf, Monty L.

    1997-02-01

    Viscosity experiments using Ostwald-type gravity flow viscometers are not new to the physical chemistry laboratory. Several physical chemistry laboratory texts (1 - 3) contain at least one experiment studying polymer solutions or other well-defined systems. Several recently published articles (4 - 8) indicated the continued interest in using viscosity measurements in the teaching lab to illustrate molecular interpretation of bulk phenomena. Most of these discussions and teaching experiments are designed around an extensive theory of viscous flow and models of molecular shape that allow a full data interpretation to be attempted. This approach to viscosity experiments may not be appropriate for all teaching situations (e.g., high schools, general chemistry labs, and nonmajor physical chemistry labs). A viscosity experiment is presented here that is designed around common seed and vegetable oils. With the importance of viscosity to foodstuffs (9) and the importance of fatty acids to nutrition (10), an experiment using these common, recognizable oils has broad appeal.

  15. EDITORIAL: MST Best Paper Award for 2003

    NASA Astrophysics Data System (ADS)

    Gill, Patrick

    2004-09-01

    For the last 12 years, Measurement Science and Technology has awarded a Best Paper prize. The Editorial Board of the journal believes that such a prize is an opportunity to thank authors for submitting their work, and serves as an integral part of the on-going quality review of the journal. An Editorial Board working party, comprising Patrick Gill (Chairman), Ralph Tatam and David Birch, was convened to determine a single contributed paper describing new and significant work, well aligned with the measurement scope of the journal, and presented in clear and rigorous form. They received a number of recommendations from the Editorial and International Advisory Board Members, and they would like to record their thanks to the Members for these recommendations, as they form an all-important first stage in the assessment process. There were responses from some 12 Board Members. In total, there were 31 papers nominated. To aid the process, additional information in the form of the 2003 MST papers top rated by referees, and the top papers ranked by most electronic accesses, was accessed. Reviews, and papers which included a Board Member as an author, were automatically excluded. From the totality of nominations and working party deliberations, there emerged a clear winner. Thus the paper recommended by the working party for the MST Best Paper Award for 2003 is: 'Extension of the torsional crystal viscometer to measurements in the time domain' by Richard F Hafer and Arno Laesecke, 14 663-673 (2003) This paper describes a significant advance in viscosity measurement using torsional vibration in piezoelectric rods. The method reported here demonstrates the use of free-decay time-domain measurements as opposed to the more established steady-state forced-mode resonance technique. The time domain technique is faster and more sensitive, with the potential for improved accuracy due to the lack of large time constants necessary for the interpretation of forced mode data. It offers a more direct approach which has the potential for absolute viscosity measurements and the establishment of a primary instrument for the measurement of viscosity standards, but also has potentially wider application for industrial viscosity measurement and process control. The paper is well structured and clearly written, with a good outline of the background to the work, a comparison of theoretical description of both forced mode and free-decay operation, and a clear description of the device. Results and data analysis are presented for both types of operation of the viscometer; the viscometer is characterized in vacuo, followed by validation with SF6 as a test fluid. The much reduced timescale for gathering the free decay data, coupled with available bench-top PC computing power, led to a significant advantage for 'on-line' data analysis, and has enabled the avoidance of non-linear operating regimes which were difficult to deal with under forced mode operation. Even without immediate knowledge and expertise in this area, the readership can gain a useful insight into the state of the art in viscometry due to the lucidity of the paper. This is illustrated in the top level quality rating that was accorded the paper at the refereeing stage. We therefore recommend this paper for the MST 2003 Best Paper Award. The working party decided also that the following article was the best Design Note in MST for 2003: 'A dispersion-free high-speed beam chopper for ultrafast-pulsed-laser applications' by J F Holzman and A Y Elezzabi, 14 N41-N44 (2003) This design note reports the development of a chopper for use at frequencies ~100 kHz, well above those possible with conventional choppers, and offers an alternative in the medium to high frequency range to electro-optic and acousto-optic modulation techniques, which can suffer from material dispersion problems and propagation-induced pulse broadening effects.

  16. Temperature dependent viscosity of cobalt ferrite / ethylene glycol ferrofluids

    NASA Astrophysics Data System (ADS)

    Kharat, Prashant B.; Somvanshi, Sandeep B.; Kounsalye, Jitendra S.; Deshmukh, Suraj S.; Khirade, Pankaj P.; Jadhav, K. M.

    2018-04-01

    In the present work, cobalt ferrite / ethylene glycol ferrofluid is prepared in 0 to 1 (in the step of 0.2) volume fraction of cobalt ferrite nanoparticles synthesized by co-precipitation method. The XRD results confirmed the formation of single phase spinel structure. The Raman spectra have been deconvoluted into individual Lorentzian peaks. Cobalt ferrite has cubic spinel structure with Fd3m space group. FT-IR spectra consist of two major absorption bands, first at about 586 cm-1 (υ1) and second at about 392 cm-1 (υ2). These absorption bands confirm the formation of spinel-structured cobalt ferrite. Brookfield DV-III viscometer and programmable temperature-controlled bath was used to study the relationship between viscosity and temperature. Viscosity behavior with respect to temperature has been studied and it is revealed that the viscosity of cobalt ferrite / ethylene glycol ferrofluids increases with an increase in volume fraction of cobalt ferrite. The viscosity of the present ferrofluid was found to decrease with increase in temperature.

  17. Co-liquefaction of spent coffee grounds and lignocellulosic feedstocks.

    PubMed

    Yang, Linxi; He, Quan Sophia; Havard, Peter; Corscadden, Kenneth; Xu, Chunbao Charles; Wang, Xuan

    2017-08-01

    Co-liquefaction of spent coffee grounds (SCG) with paper filter (PF), corn stalk (CS) and white pine bark (WPB) respectively, was examined in subcritical water for bio-crude oil production. The optimum reaction temperature was 250°C, and the mixing biomass ratio was 1:1. SCG and CS was identified to be the best feedstock combination with a significant positive synergetic effect in the co-liquefaction process with 5% NaOH as a catalyst. The yield of bio-crude oil was increased by 20.9% compared to the mass averaged yield from two feedstocks, and the oil quality was also improved in terms of viscosity and relative molecular mass. A negative effect presented in the co-liquefaction of SCG/WPB. The resulting bio-crude oils were characterized by elemental analyzer, GC-MS, GPC and viscometer, indicating that mixing feedstock in the co-liquefaction process also influenced the higher heating value (HHV), viscosity, molecular mass and chemical composition of bio-crude oil. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Effects of flow on insulin fibril formation at an air/water interface

    NASA Astrophysics Data System (ADS)

    Posada, David; Heldt, Caryn; Sorci, Mirco; Belfort, Georges; Hirsa, Amir

    2009-11-01

    The amyloid fibril formation process, which is implicated in several diseases such as Alzheimer's and Huntington's, is characterized by the conversion of monomers to oligomers and then to fibrils. Besides well-studied factors such as pH, temperature and concentration, the kinetics of this process are significantly influenced by the presence of solid or fluid interfaces and by flow. By studying the nucleation and growth of a model system (insulin fibrils) in a well-defined flow field with an air/water interface, we can identify the flow conditions that impact protein aggregation kinetics both in the bulk solution and at the air/water interface. The present flow system (deep-channel surface viscometer) consists of an annular region bounded by stationary inner and outer cylinders, an air/water interface, and a floor driven at constant rotation. We show the effects of Reynolds number on the kinetics of the fibrillation process both in the bulk solution and at the air/water interface, as well as on the structure of the resultant amyloid aggregates.

  19. Newtonian to non-Newtonian flow transition in lung surfactants

    NASA Astrophysics Data System (ADS)

    Sadoughi, Amir; Hirsa, Amir; Lopez, Juan

    2010-11-01

    The lining of normal lungs is covered by surfactants, because otherwise the surface tension of the aqueous layer would be too large to allow breathing. A lack of functioning surfactants can lead to respiratory distress syndrome, a potentially fatal condition in both premature infants and adults, and a major cause of death in the US and world-wide. We use a home-built Brewster angle microscope on an optically accessible deep channel viscometer to simultaneously observe the mesoscale structures of DPPC, the primary constituent of lung surfactant, on water surface and measure the interfacial velocity field. The measured interfacial velocity is compared to Navier-Stokes computations with the Boussinesq-Scriven surface model. Results show that DPPC monolayer behaves i) purely elastically at low surface pressures on water, ii) viscoelastically at modest surface pressures, exhibiting non-zero surface shear viscosity that is independent of the shear rate and flow inertia, and iii) at surface pressures approaching film collapse, DPPC loses its fluid characteristics, and a Newtonian surface model no longer captures its hydrodynamics.

  20. Intermolecular interaction studies of glyphosate with water

    NASA Astrophysics Data System (ADS)

    Manon, Priti; Juglan, K. C.; Kaur, Kirandeep; Sethi, Nidhi; Kaur, J. P.

    2017-07-01

    The density (ρ), viscosity (η) and ultrasonic velocity (U) of glyphosate with water have been measured on different ultrasonic frequency ranges from 1MHz, 2MHz, 3MHz & 5MHz by varying concentrations (0.05%, 0.10%, 0.15%, 0.20%, 0.25%, 0.30%, 0.35%, & 0.40%) at 30°C. The specific gravity bottle, Ostwald's viscometer and quartz crystal interferometer were used to determine density (ρ), viscosity (η) and ultrasonic velocity (U). These three factors contribute in evaluating the other parameters as acoustic impedance (Z), adiabatic compressibility (β), relaxation time (τ), intermolecular free length (Lf), free volume (Vf), ultrasonic attenuation (α/f2), Rao's constant (R), Wada's constant (W) and relative strength (R). Solute-solvent interaction is confirmed by ultrasonic velocity and viscosity values, which increases with increase in concentration indicates stronger association between solute and solvent molecules. With rise in ultrasonic frequency the interaction between the solute and solvent particles decreases. The linear variations in Rao's constant and Wada's constant suggest the absence of complex formation.

  1. Thermal conductivity and viscosity measurements of ethylene glycol-based Al2O3 nanofluids

    NASA Astrophysics Data System (ADS)

    Pastoriza-Gallego, María José; Lugo, Luis; Legido, José Luis; Piñeiro, Manuel M.

    2011-12-01

    The dispersion and stability of nanofluids obtained by dispersing Al2O3 nanoparticles in ethylene glycol have been analyzed at several concentrations up to 25% in mass fraction. The thermal conductivity and viscosity were experimentally determined at temperatures ranging from 283.15 K to 323.15 K using an apparatus based on the hot-wire method and a rotational viscometer, respectively. It has been found that both thermal conductivity and viscosity increase with the concentration of nanoparticles, whereas when the temperature increases the viscosity diminishes and the thermal conductivity rises. Measured enhancements on thermal conductivity (up to 19%) compare well with literature values when available. New viscosity experimental data yield values more than twice larger than the base fluid. The influence of particle size on viscosity has been also studied, finding large differences that must be taken into account for any practical application. These experimental results were compared with some theoretical models, as those of Maxwell-Hamilton and Crosser for thermal conductivity and Krieger and Dougherty for viscosity.

  2. Viscosity Measurements of Ethyl Fluoride (R161) from 243 K to 363 K at Pressures up to 30 MPa

    NASA Astrophysics Data System (ADS)

    Meng, Xianyang; Gu, Xiaoyun; Wu, Jiangtao; Bi, Shengshan

    2015-11-01

    The Montreal Protocol and its subsequent amendments have created a schedule to replace ozone depletion substances, such as chlorofluorocarbons and hydrochlorofluorocarbons, with chlorine-free molecules in several industrial applications. Ethyl fluoride (R161, C2H5F, 353-36-6) was found to be a potential alternative refrigerant for the replacement of controlled substances, such as R22 with excellent cycle performance. In this work, the viscosity of ethyl fluoride is reported at temperatures from 243 K to 363 K and at pressures from saturation pressure to 30 MPa. The experiment was performed with a calibrated vibrating-wire viscometer, which exhibited a combined expanded uncertainty of 2.5 % with a level of confidence of 0.95 (k = 2) for such a fluid. A scheme based on a hard-spheres model was used to correlate the experimental results. The average absolute deviation of the experimental results from the correlations for R161 is 0.88 %.

  3. Oscillatory shear rheology measurements and Newtonian modeling of insoluble monolayers

    NASA Astrophysics Data System (ADS)

    Rasheed, Fayaz; Raghunandan, Aditya; Hirsa, Amir H.; Lopez, Juan M.

    2017-04-01

    Circular systems are advantageous for interfacial studies since they do not suffer from end effects, but their hydrodynamics is more complicated because their flows are not unidirectional. Here, we analyze the shear rheology of a harmonically driven knife-edge viscometer through experiments and computations based on the Navier-Stokes equations with a Newtonian interface. The measured distribution of phase lag in the surface velocity relative to the knife-edge speed is found to have a good signal-to-noise ratio and provides robust comparisons to the computations. For monomolecular films of stearic acid, the surface shear viscosity deduced from the model was found to be the same whether the film is driven steady or oscillatory, for an order of magnitude range in driving frequencies and amplitudes. Results show that increasing either the amplitude or forcing frequency steepens the phase lag next to the knife edge. In all cases, the phase lag is linearly proportional to the radial distance from the knife edge and scales with surface shear viscosity to the power -1 /2 .

  4. A Review on the Role of Vibrational Spectroscopy as An Analytical Method to Measure Starch Biochemical and Biophysical Properties in Cereals and Starchy Foods

    PubMed Central

    Cozzolino, D.; Degner, S.; Eglinton, J.

    2014-01-01

    Starch is the major component of cereal grains and starchy foods, and changes in its biophysical and biochemical properties (e.g., amylose, amylopectin, pasting, gelatinization, viscosity) will have a direct effect on its end use properties (e.g., bread, malt, polymers). The use of rapid and non-destructive methods to study and monitor starch properties, such as gelatinization, retrogradation, water absorption in cereals and starchy foods, is of great interest in order to improve and assess their quality. In recent years, near infrared reflectance (NIR) and mid infrared (MIR) spectroscopy have been explored to predict several quality parameters, such as those generated by instrumental methods commonly used in routine analysis like the rapid visco analyser (RVA) or viscometers. In this review, applications of both NIR and MIR spectroscopy to measure and monitor starch biochemical (amylose, amylopectin, starch) and biophysical properties (e.g., pasting properties) will be presented and discussed. PMID:28234340

  5. Viscosities of nonelectrolyte liquid mixtures. III. Selected binary and quaternary mixtures

    NASA Astrophysics Data System (ADS)

    Wakefield, D. L.

    1988-05-01

    This paper is the final in a series of three viscosity and density studies of pure n-alkanes and selected binary and quaternary mixtures. A standard U-tube viscometer was used for viscosity measurements, and a Pyrex flask-type pycnometer was used for density determinations. Results are given here for pure alkane and selected binary mixtures of n-tetradecane + n-octane, for selected quaternary mixtures of n-hexadecane + n-dodecane + n-decane + n-hexane, and for pure and selected quaternary mixtures of n-hexadecane + n-dodecane + n-nonane + n-heptane at 303.16 and 308.16 K. The principle of congruence was tested, as was the Grunberg and Nissan equation, as they have been shown to be useful as prediction techniques for other n-alkane binary mixtures. Comparisons were made between the two groups of quaternary alkane mixtures and the binary n-tetradecane + n-octane mixtures of the same “pseudo” composition to understand better the dependence of mixture viscosities on the composition parameter.

  6. Steady Shear Viscosities of Two Hard Sphere Colloidal Dispersions

    NASA Astrophysics Data System (ADS)

    Cheng, Zhengdong; Chaikin, Paul M.; Phan, See-Eng; Russel, William B.; Zhu, Jixiang

    1996-03-01

    Though hard spheres have the simplest inter-particle potential, the many body hydrodynamic interactions are complex and the rheological properties of dispersions are not fully understood in the concentrated regime. We studied two model systems: colloidal poly-(Methyl Methacrylate) spheres with a grafted layer of poly-(12-hydroxy stearic acid) (PMMA/PHSA) and spherical Silica particles (PST-5, Nissan Chemical Industries, Ltd, Tokyo, Japan). Steady shear viscosities were measured by a Zimm viscometer. The high shear relative viscosity of the dispersions compares well with other hard sphere systems, but the low shear relative viscosity of PMMA/PHSA dispersions is η / η 0 = 50 at φ = 0.5 , higher than η / η 0 = 22 for other hard sphere systems, consistent with recently published data (Phys. Rev. Lett. 75(1995)958). Bare Silica spheres are used to clarify the effect of the grafted layer. With the silica spheres, volume fraction can be determined independent of intrinsic viscosity measurements; also, higher concentrated dispersions can be made.

  7. Effect of Oils on Kinematic Viscosity of R134a

    NASA Astrophysics Data System (ADS)

    Sato, Tomoaki; Takaishi, Yoshinori; Oguchi, Kosei

    The kinematic viscosity defined as a ratio of viscosity to density is one of the key properties in producing technically important dimensionless numbers such as Prandtl and Reynolds numbers. We measured both viscosity and density of R134a/POE and R134a/PAG mixtures at saturation in the range of relatively low oilconcentrations. The density measurements for oil-concentrations up to 50 mass% were conducted with a densimeter making use of glass buoys within overall uncertainty of ±1.0%, and the viscosity measurements for oil-concentrations up to 16 mass% were carried out with an oscillating-cup viscometer making use of polarizer with overall uncertainty less than ±3.5%. The kinematic viscosities obtained from the experimental viscosity and density data are presented for both R134a/POE and R134a/PAG mixtures in the range of temperatures from 278 K to 288 K for oil-concentrations up to 15 mass%. The oil-concentration dependence of the kinematic viscosity for both mixtures is also reported.

  8. Sinusoidal Forcing of Interfacial Films

    NASA Astrophysics Data System (ADS)

    Rasheed, Fayaz; Raghunandan, Aditya; Hirsa, Amir; Lopez, Juan

    2015-11-01

    Fluid transport, in vivo, is accomplished via pumping mechanisms of the heart and lungs, which results in biological fluids being subjected to oscillatory shear. Flow is known to influence biological macromolecules, but predicting the effect of shear is incomplete without also accounting for the influence of complex interfaces ubiquitous throughout the body. Here, we investigated the oscillatory response of the structure of aqueous interfacial films using a cylindrical knife edge viscometer. Vitamin K1 was used as a model monolayer because its behaviour has been thoroughly quantified and it doesn't show any measurable hysteresis. The monolayer was subjected to sinusoidal forcing under varied conditions of surface concentrations, periodic frequencies, and knife edge amplitudes. Particle Image Velocimetry(PIV) data was collected using Brewster Angle Microscopy(BAM), revealing the influence of oscillatory interfacial shear stress on the monolayer. Insights were gained as to how the velocity profile dampens at specific distances from the knife edge contact depending on the amplitude, frequency, and concentration of Vitamin K1. Supported by NNX13AQ22G, National Aeronautics and Space Administration.

  9. Human endothelial cell responses to cardiovascular inspired pulsatile shear stress

    NASA Astrophysics Data System (ADS)

    Watson, Matthew; Baugh, Lauren; Black, Lauren, III; Kemmerling, Erica

    2016-11-01

    It is well established that hemodynamic shear stress regulates blood vessel structure and the development of vascular pathology. This process can be studied via in vitro models of endothelial cell responses to pulsatile shear stress. In this study, a macro-scale cone and plate viscometer was designed to mimic various shear stress waveforms found in the body and apply these stresses to human endothelial cells. The device was actuated by a PID-controlled DC gear-motor. Cells were exposed to 24 hours of pulsatile shear and then imaged and stained to track their morphology and secretions. These measurements were compared with control groups of cells exposed to constant shear and no shear. The results showed that flow pulsatility influenced levels of secreted proteins such as VE-cadherin and neuroregulin IHC. Cell morphology was also influenced by flow pulsatility; in general cells exposed to pulsatile shear stress developed a higher aspect ratio than cells exposed to no flow but a lower aspect ratio than cells exposed to steady flow.

  10. Tuning Fork Oscillators as Downhole Viscometers in Oilfield Applications

    NASA Astrophysics Data System (ADS)

    Gonzalez, Miguel; Bernero, Greg; Alvarez, Oliverio; Ham, Gregory; Max, Deffenbaugh; Sensors Development Team

    2015-03-01

    The commerciality of oil wells is greatly influenced by the physical properties of the fluids being produced. A key parameter in determining how producible the hydrocarbons are is their viscosity. Pressure and temperature changes in recovering a downhole sample to the surface can alter viscosity while accurate downhole measurement of this critical property remains a rudimentary effort in the industry. In this presentation we describe the challenges of measuring and quantifying the viscosity of reservoir fluids in situ at downhole conditions, as well as present an overview of some of the different measurement techniques currently used. Additionally, we show our characterization of a piezoelectric tuning fork oscillator used as a viscosity sensor. In an attempt to recreate the environment found in oil wells, its mechanical and electrical properties were studied while the device was immersed in different fluids and, separately, under different conditions of pressure and temperature. This device is a first step toward the development of an inexpensive, integrated, and miniaturized sensing platform for the in situ characterization of reservoir fluids.

  11. Simulation model based on non-newtonian fluid mechanics applied to the evaluation of the embolic effect of emulsions of iodized oil and anticancer drug.

    PubMed

    Demachi, H; Matsui, O; Abo, H; Tatsu, H

    2000-01-01

    To verify the difference in embolic effect between oil-in-water (O-W) and water-in-oil (W-O) emulsions composed of iodized oil and an anticancer drug, epirubicin, using a simulation model based on non-Newtonian fluid mechanics. Flow curves of pure iodized oil and two types of O-W and W-O emulsions immediately and 1 hr after preparation were examined with a viscometer. Using the yield stress data obtained, we simulated the stagnation of each fluid with steady flow in a rigid tube. The W-O emulsions were observed to stagnate in the thin tube at a low pressure gradient. However, the embolic effect of the W-O emulsions decreased 1 hr after preparation. The O-W emulsions were stable and did not stagnate under the conditions in which the W-O emulsions stagnated. The simulation model showed that the embolic effect of the W-O emulsions was superior to that of the O-W emulsions.

  12. Clinical diagnostic of pleural effusions using a high-speed viscosity measurement method

    NASA Astrophysics Data System (ADS)

    Hurth, Cedric; Klein, Katherine; van Nimwegen, Lena; Korn, Ronald; Vijayaraghavan, Krishnaswami; Zenhausern, Frederic

    2011-08-01

    We present a novel bio-analytical method to discriminate between transudative and exudative pleural effusions based on a high-speed video analysis of a solid glass sphere impacting a liquid. Since the result depends on the solution viscosity, it can ultimately replace the battery of biochemical assays currently used. We present results obtained on a series of 7 pleural effusions obtained from consenting patients by analyzing both the splash observed after the glass impactor hits the liquid surface, and in a configuration reminiscent of the drop ball viscometer with added sensitivity and throughput provided by the high-speed camera. The results demonstrate distinction between the pleural effusions and good correlation with the fluid chemistry analysis to accurately differentiate exudates and transudates for clinical purpose. The exudative effusions display a viscosity around 1.39 ± 0.08 cP whereas the transudative effusion was measured at 0.89 ± 0.09 cP, in good agreement with previous reports.

  13. Surface temperatures and glassy state investigations in tribology

    NASA Technical Reports Server (NTRS)

    Bair, S.; Winer, W. O.

    1980-01-01

    Measurements were made of the limiting shear stress for two naphthenic oils of differing molecular weight and three blends of the lower molecular weight oil and polymers of differing molecular weight. All reached the same limiting shear stress for the same temperature and pressure; although the polymer solutions reduced the limiting shear stress by about fifteen percent. A falling body viscometer was constructed to operate to 230 C and to 0.6 GPa and another was constructed to extend the pressure range to 1.1 GPa. A concentrated contact simulator was developed which allows recording of the traction force while the slide-roll ratio is continuously varied and the rolling speed is maintained essentially constant. Measurement of lubricant minimum film thickness of elliptical EHD contacts of various aspect ratios were made by optical interferometry. The experimental data were thirty percent greater than that predicted by the Hamrock and Dowson model. Preliminary development of the application of a scanning infrared radiation system to a tribological system was completed.

  14. ADVANCED CUTTINGS TRANSPORT STUDY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefan Miska; Nicholas Takach; Kaveh Ashenayi

    2004-07-31

    We have tested the loop elevation system. We raised the mast to approximately 25 to 30 degrees from horizontal. All went well. However, while lowering the mast, it moved laterally a couple of degrees. Upon visual inspection, severe spalling of the concrete on the face of the support pillar, and deformation of the steel support structure was observed. At this time, the facility is ready for testing in the horizontal position. A new air compressor has been received and set in place for the ACTS test loop. A new laboratory has been built near the ACTS test loop Roughened cupsmore » and rotors for the viscometer (RS300) were obtained. Rheologies of aqueous foams were measured using three different cup-rotor assemblies that have different surface roughness. The relationship between surface roughness and foam rheology was investigated. Re-calibration of nuclear densitometers has been finished. The re-calibration was also performed with 1% surfactant foam. A new cuttings injection system was installed at the bottom of the injection tower. It replaced the previous injection auger. A mechanistic model for cuttings transport with aerated mud has been developed. Cuttings transport mechanisms with aerated water at various conditions were experimentally investigated. A total of 39 tests were performed. Comparisons between the model predictions and experimental measurements show a satisfactory agreement. Results from the ultrasonic monitoring system indicated that we could distinguish between different sand levels. We also have devised ways to achieve consistency of performance by securing the sensors in the caps in exactly the same manner as long as the sensors are not removed from the caps. A preliminary test was conducted on the main flow loop at 100 gpm flow rate and 20 lb/min cuttings injection rate. The measured bed thickness using the ultrasonic method showed a satisfactory agreement with nuclear densitometer readings. Thirty different data points were collected after the test section was put into liquid holdup mode. Readings indicated 2.5 to 2.7 inches of sand. The corresponding nuclear densitometers readings were between 2.5 and 3.1 inches. Lab tests were conducted to check an on-line viewing system. Sharp images were obtained through a CCD camera with the use of a ring light or fiber light. A prototype device for measuring the average bubble size for the foam generator-viscometer was constructed from a 1/2 inch fitting. The new windowed cell has been received and installed on the ACTF Bubble Characterization Cart.« less

  15. Thermal conductivity and viscosity measurements of ethylene glycol-based Al2O3 nanofluids

    PubMed Central

    2011-01-01

    The dispersion and stability of nanofluids obtained by dispersing Al2O3 nanoparticles in ethylene glycol have been analyzed at several concentrations up to 25% in mass fraction. The thermal conductivity and viscosity were experimentally determined at temperatures ranging from 283.15 K to 323.15 K using an apparatus based on the hot-wire method and a rotational viscometer, respectively. It has been found that both thermal conductivity and viscosity increase with the concentration of nanoparticles, whereas when the temperature increases the viscosity diminishes and the thermal conductivity rises. Measured enhancements on thermal conductivity (up to 19%) compare well with literature values when available. New viscosity experimental data yield values more than twice larger than the base fluid. The influence of particle size on viscosity has been also studied, finding large differences that must be taken into account for any practical application. These experimental results were compared with some theoretical models, as those of Maxwell-Hamilton and Crosser for thermal conductivity and Krieger and Dougherty for viscosity. PMID:21711737

  16. Integrated rheology model: Explosive Composition B-3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Stephen M.; Zerkle, David K.; Smilowitz, Laura B.

    Composition B-3 (Comp B-3) is a high explosive formulation composed of 60/40wt% RDX (1,3,5-trinitroperhydro-1,3,5-triazine) /TNT (2,4,6 trinitrotoluene). Above approximately 78°C this formulation partially melts to form a multiphase system with solid RDX particles in a molten TNT matrix. This multiphase system presents a number of phenomena that influence its apparent viscosity. In an earlier study explosive Composition B-3 (Comp B-3, 60/40wt% RDX/TNT) was examined for evidence of yield stress using a non-isothermal falling ball viscometer and a yield stress model was proposed in this paper. An integrated viscosity model suitable for use in computational fluid dynamics (CFD) simulations is developedmore » to capture the transition from a heterogeneous solid to a Bingham viscoplastic fluid. This viscosity model is used to simulate the motion of imbedded spheres falling through molten Comp B-3. Finally, comparison of the simulations to physical tests show agreement between the positions predicted by the model and the measured locations of the spheres as a function of temperature between 90C and 165C.« less

  17. A comparison of calculated and measured rheological properties of crystallising lavas in the field and in the laboratory

    NASA Technical Reports Server (NTRS)

    Pinkerton, Harry; Norton, Gill

    1993-01-01

    Models of most magmatic processes, including realistic models of planetary lava flows require accurate data on the rheological properties of magma. Previous studies suggest that field and laboratory rheological properties of Hawaiian lavas can be calculated from their physico-chemical properties using a non-Newtonian rheology model. The present study uses new measurements of the rheological properties of crystallizing lavas to show that this is also true for lavas from Mount Etna. Rheological measurements on quenched Etna basalts were made in a specially designed furnace using a Haake Rotovisco viscometer attached to a spindle which has been designed to eliminate slippage at the melt-spindle interface. Using this spindle, we have made measurements at lower temperatures than other workers in this field. From these measurements, Mount Etna lavas are Newtonian at temperatures above 1120 C and they are thixotropic pseudoplastic fluids with a yield strength at lower temperatures. The close agreement between calculated and measured rheology over the temperature range 1084 - 1125 C support the use of the non-Newtonian rheology model in future modeling of planetary lava flows.

  18. Rheological Behavior and Microstructure of Ceramic Particulate/Aluminum Alloy Composites. Ph.D. Thesis Final Technical Report

    NASA Technical Reports Server (NTRS)

    Moon, Hee-Kyung

    1990-01-01

    The rheological behavior and microstructure were investigated using a concentric cylinder viscometer for three different slurries: semi-solid alloy slurries of a matrix alloy, Al-6.5wt percent Si: composite slurries, SiC (sub p) (8.5 microns)/Al-6.5wt percent Si, with the same matrix alloy in the molten state, and composite slurries of the same composition with the matrix alloy in the semi-solid state. The pseudoplasticity of these slurries was obtained by step changes of the shear rate from a given initial shear rate. To study the thixotropic behavior of the system, a slurry was allowed to rest for different periods of time, prior to shearing at a given initial shear rate. In the continuous cooling experiments, the viscosities of these slurries were dependent on the shear rate, cooling rate, volume fraction of the primary solid of the matrix alloy, and volume fraction of silicon carbide. In the isothermal experiments, all three kinds of slurries exhibited non-Newtonian behavior, depending on the volume fraction of solid particles.

  19. Selected physical properties of various diesel blends

    NASA Astrophysics Data System (ADS)

    Hlaváčová, Zuzana; Božiková, Monika; Hlaváč, Peter; Regrut, Tomáš; Ardonová, Veronika

    2018-01-01

    The quality determination of biofuels requires identifying the chemical and physical parameters. The key physical parameters are rheological, thermal and electrical properties. In our study, we investigated samples of diesel blends with rape-seed methyl esters content in the range from 3 to 100%. In these, we measured basic thermophysical properties, including thermal conductivity and thermal diffusivity, using two different transient methods - the hot-wire method and the dynamic plane source. Every thermophysical parameter was measured 100 times using both methods for all samples. Dynamic viscosity was measured during the heating process under the temperature range 20-80°C. A digital rotational viscometer (Brookfield DV 2T) was used for dynamic viscosity detection. Electrical conductivity was measured using digital conductivity meter (Model 1152) in a temperature range from -5 to 30°C. The highest values of thermal parameters were reached in the diesel sample with the highest biofuel content. The dynamic viscosity of samples increased with higher concentration of bio-component rapeseed methyl esters. The electrical conductivity of blends also increased with rapeseed methyl esters content.

  20. Weak "A" blood subgroup discrimination by a rheo-optical method: a new application of laser backscattering

    NASA Astrophysics Data System (ADS)

    Rasia, Rodolfo J.; Rasia-Valverde, Juana R.; Stoltz, Jean F.

    1996-01-01

    Laser backscattering is an excellent tool to investigate size and concentration of suspended particles. It was successfully applied to the analysis of erythrocyte aggregation. A method is proposed that applies laser backscattering to the evaluation of the strength of the immunologic erythrocyte agglutination by approaching the energy required for the mechanical dissociation of agglutinates. Mills and Snabre have proposed a theory of laser backscattering for erythrocyte aggregation analysis. It is applied here to analyze the dissociation process of erythrocyte agglutinates performed by imposing a constant shear rate to the agglutinate suspension in a couette viscometer until a dispersion of isolated red cells is attained. Experimental verifications of the method were performed on the erythrocytes of the ABO group reacting against an anti-A test serum in twofold series dilutions. Spent energy is approached by a numerical process carried out on the backscattered intensity data registered during mechanical dissociation. Velocities of agglutination and dissociation lead to the calculation of dissociation parameters These values are used to evaluate the strength of the immunological reaction and to discriminate weak subgroups of ABO system.

  1. Fluorescent BODIPY Rotor: Viscometer for Cellular Organelles and Membrane-Mimicking Vesicles

    NASA Astrophysics Data System (ADS)

    Kimball, J.; Raut, S.; Fudala, R.; Doan, H.; Maliwal, B.; Sabnis, N.; Lacko, A.; Gryczynski, I.; Dzyuba, S.; Gryczynski, Z.

    2015-03-01

    Many cellular processes, such as mass and signal transport, metabolism and protein-protein interactions are governed in part by diffusion, and thus affected by their local microviscosity. Changes in this microviscosity has also been linked to various diseases, including atherosclerosis, Alzheimer's disease and diabetes. Therefore, directly measuring the heterogeneous viscosity of cellular constitutes can lead to greater understanding of these processes. To this effect, a novel homodiemeric BODIPY dye was evaluated as a fluorescent rotor probe for this application. A linear dependence on viscosity in the range of typical cellular microviscosity was established for steady-state and time-resolved properties of the dye. It was then embedded in vitro to membrane-mimicking lipid vesicles (DPPC, POPC, and POPC plus cholesterol) and results indicated it to be a viable sensor for lifetime-based determination of microviscosity. The BODIPY dye was lastly endocytosed by SKOV3 cells and Fluorescence Lifetime Imaging Microscopy (FLIM) was performed, successfully mapping the viscosity of internal cell components. This work was supported by the NIH Grant R01EB12003, the NSF Grant CBET-1264608, and the INFOR Grant from TCU.

  2. Validation of a high-performance size-exclusion chromatography method to determine and characterize β-glucans in beer wort using a triple-detector array.

    PubMed

    Tomasi, Ivan; Marconi, Ombretta; Sileoni, Valeria; Perretti, Giuseppe

    2017-01-01

    Beer wort β-glucans are high-molecular-weight non-starch polysaccharides of that are great interest to the brewing industries. Because glucans can increase the viscosity of the solutions and form gels, hazes, and precipitates, they are often related to poor lautering performance and beer filtration problems. In this work, a simple and suitable method was developed to determine and characterize β-glucans in beer wort using size exclusion chromatography coupled with a triple-detector array, which is composed of a light scatterer, a viscometer, and a refractive-index detector. The method performances are comparable to the commercial reference method as result from the statistical validation and enable one to obtain interesting parameters of β-glucan in beer wort, such as the molecular weight averages, fraction description, hydrodynamic radius, intrinsic viscosity, polydispersity and Mark-Houwink parameters. This characterization can be useful in brewing science to understand filtration problems, which are not always explained through conventional analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Viscometric investigation of compatibilization of the poly(vinyl chloride)/poly(ethylene-co-vinyl acetate) blends by terpolymer of maleic anhydride styrene vinyl acetate

    NASA Astrophysics Data System (ADS)

    İmren, Dilek; Boztuğ, Ali; Yılmaz, Ersen; Zengin, H. Bayram

    2008-11-01

    In this study, a blend of poly(vinyl chloride) (PVC)/ethylene-co-vinyl acetate (EVA) was compatibilized by terpolymer of maleic anhydride-styrene-vinyl acetate (MAStVA) used as a compatibilizer. It was prepared the blends of 50/50 PVC/EVA containing 2-10% of the terpolymer. The compatibility experiences of these blends were investigated by using viscometric method in the range of concentrations (0.5-2.0 g dL -1) where tetrahydrofuran (THF) is the solvent. The interaction parameter (Δ b) was used to study the miscibility and compatibility of polymer blend in solution, obtained from the modified Krigbaum and Wall theory. Turbidity and FTIR measurements were also used to investigate the miscibility of this pair of polymers. The values of the relative viscosities of the each polymer solution and their blends were measured by a Cannon-Fenske type viscometer. In consequence of the study, it was observed that a considerable improvement was achieved in the miscibility of PVC/EVA blends by adding among 5 and 10 wt% of compatibilizer.

  4. A Comparison of the Viscosities of Thickened Liquids for Pediatric Dysphagia.

    NASA Astrophysics Data System (ADS)

    Wijesinghe, Ranjith; Clifton, Mekale; Tarlton, Morgan; Heinsohn, Erica; Ewing, Mary

    It has been reported that Speech Language Pathologists in different facilities across the nation use a variety of thickening agents and recipes as therapeutic measures for infants and children diagnosed with dysphagia. Limited research has been completed in this area. Viscosity was tested to determine the thickness of each thickening agent mixed with infant formula. The values were then compared to the National Dysphagia Diet liquid levels to determine which thickening agent resulted in the desired viscosity levels. The thickeners were mixed with common infant formulas and soy formulas to determine if the type of formula impacted the viscosity. The main goal was to determine if the assumed thickness level (viscosity) of prescribed thickened liquids was actually being met. This topic is of high concern because of its impact on the safety and well-being of clients with dysphagia. A viscometer was used to collect the viscosity levels. Commercially available formulas selected for this study. The final results of our investigation will be presented during the APS meeting. This work is supported by a Ball State University Immersive Learning Grant.

  5. Integrated rheology model: Explosive Composition B-3

    DOE PAGES

    Davis, Stephen M.; Zerkle, David K.; Smilowitz, Laura B.; ...

    2018-03-20

    Composition B-3 (Comp B-3) is a high explosive formulation composed of 60/40wt% RDX (1,3,5-trinitroperhydro-1,3,5-triazine) /TNT (2,4,6 trinitrotoluene). Above approximately 78°C this formulation partially melts to form a multiphase system with solid RDX particles in a molten TNT matrix. This multiphase system presents a number of phenomena that influence its apparent viscosity. In an earlier study explosive Composition B-3 (Comp B-3, 60/40wt% RDX/TNT) was examined for evidence of yield stress using a non-isothermal falling ball viscometer and a yield stress model was proposed in this paper. An integrated viscosity model suitable for use in computational fluid dynamics (CFD) simulations is developedmore » to capture the transition from a heterogeneous solid to a Bingham viscoplastic fluid. This viscosity model is used to simulate the motion of imbedded spheres falling through molten Comp B-3. Finally, comparison of the simulations to physical tests show agreement between the positions predicted by the model and the measured locations of the spheres as a function of temperature between 90C and 165C.« less

  6. A novel poly(acrylic acid-co-acrylamide)/diatomite composite flocculant with outstanding flocculation performance.

    PubMed

    Xu, Kun; Liu, Yao; Wang, Yang; Tan, Ying; Liang, Xuecheng; Lu, Cuige; Wang, Haiwei; Liu, Xiusheng; Wang, Pixin

    2015-01-01

    Series of anionic flocculants with outstanding flocculation performance, poly(acrylic acid-co-acrylamide)/diatomite composite flocculants (PAAD) were successfully prepared through aqueous solution copolymerization and applied to flocculate from oil-field fracturing waste-water. The structure of PAAD was characterized by Fourier transform infra-red spectroscopy, (13)C nuclear magnetic resonance and X-ray diffraction tests, and its properties were systematically evaluated by viscometer, thermogravimetry analysis and flocculation measurements. Furthermore, the influences of various reaction parameters on the apparent viscosity of flocculant solution were studied, and the optimum synthesis condition was determined. The novel composite flocculants exhibited outstanding flocculation properties. Specifically, the dosage of composite flocculants that could make the transmittance of treated wastewater exceed 90% was only approximately 12-35 ppm, which was far lower than that of conventional flocculants. Meanwhile, the settling time was lower than 5 s, which was similar to that of conventional flocculants. This was because PAAD flocculants had a higher absorption capacity, and larger chain extending space than conventional linear flocculants, which could refrain from the entanglement of linear polymer chains and significantly improve flocculation capacity.

  7. Volumetric Properties, Viscosities, and Refractive Indices of the Binary Systems 1-Butanol + PEG 200, + PEG 400, and + TEGDME

    NASA Astrophysics Data System (ADS)

    Živković, N.; Šerbanović, S.; Kijevčanin, M.; Živković, E.

    2013-06-01

    Densities, viscosities, and refractive indices of three binary systems consisting of 1-butanol with polyethylene glycols of different molecular weights (PEG 200 and PEG 400) or tetraethylene glycol dimethyl ether (TEGDME) were measured at ten temperatures (288.15, 293.15, 298.15, 303.15, 308.15, 313.15, 318.15, 323.15, 328.15, and 333.15) K and atmospheric pressure. Densities of the selected binary mixtures were measured with an Anton Paar DMA 5000 digital vibrating U-tube densimeter, refractive indices were measured with an automatic Anton Paar RXA-156 refractometer, while for viscosity measurements, a digital Stabinger SVM 3000/G2 viscometer was used. From these data, excess molar volumes were calculated and fitted to the Redlich-Kister equation. The obtained results have been analyzed in terms of specific molecular interactions and mixing behavior between mixture components, as well as the influence of temperature on them. Viscosity data were also correlated by Grunberg-Nissan, Eyring-UNIQUAC, three-body McAlister, and Eyring-NRTL models.

  8. Estimation of Rheological Properties of Viscous Debris Flow Using a Belt Conveyor

    NASA Astrophysics Data System (ADS)

    Hübl, J.; Steinwendtner, H.

    2000-09-01

    Rheological parameters of viscous debris flows are influenced by a great amount of factors and are therefore extremely difficult to estimate. Because of this uncertainties a belt conveyor (conveyor channel) was constructed to measure flow behaviour and rheological properties of natural debris flow material. The upward movement of the smooth rubberised belt between fixed lateral plastic walls causes a stationary wave relative to these bends. This special experimental design enables to study behaviour of viscous ebris flow material with maximum grain diameters up to 20 mm within several minutes and to hold measuring equipment very simple. The conveyor channel was calibrated first with Xanthan, a natural polysaccharide used as thickener in food technology, whose rheological properties are similar to viscous debris flow material. In a second step natural debris flow material was investigated. Velocities and rheological parameters were measured with varying solid concentration and slope of the channel. In cases where concentration of coarse particles exceed around 15% by volume the conveyor channel obtains an alternative to expensive commercial viscometers for determination of rheological parameters of viscous debris flows.

  9. Measurement of the steady-state shear characteristics of filamentous suspensions using turbine, vane, and helical impellers.

    PubMed

    Svihla, C K; Dronawat, S N; Donnelly, J A; Rieth, T C; Hanley, T R

    1997-01-01

    The impeller viscometer technique is frequently used to characterize the rheology of filamentous suspensions in order to avoid difficulties encountered with conventional instruments. This work presents the results of experiments conducted with vane, turbine, and helical impellers. The validity of the assumptions made in the determination of the torque and shear-rate constants were assessed for each impeller type. For the turbine and vane impellers, an increase in the apparent torque constant c was observed with increasing Reynolds number even when measurements were confined to the viscous regime. The shear-rate constants determined for the vane and turbine impellers varied for different calibration fluids, which contradicts the assumptions usually invoked in the analysis of data for this technique. When the helical impeller was calibrated, consistent values for the torque and shear-rate constants were obtained. The three impeller types were also used to characterize the rheology of cellulose fiber suspensions and the results compared for consistency and reproducibility. The results have application in design of rheometers for use in process control and product quality assessment in the fermentation and pulp and paper industries.

  10. Viscosities of Fe Ni, Fe Co and Ni Co binary melts

    NASA Astrophysics Data System (ADS)

    Sato, Yuzuru; Sugisawa, Koji; Aoki, Daisuke; Yamamura, Tsutomu

    2005-02-01

    Viscosities of three binary molten alloys consisting of the iron group elements, Fe, Ni and Co, have been measured by using an oscillating cup viscometer over the entire composition range from liquidus temperatures up to 1600 °C with high precision and excellent reproducibility. The viscosities measured showed good Arrhenius linearity for all the compositions. The viscosities of Fe, Ni and Co as a function of temperature are as follows: \\eqalign{ & \\log \\eta={-}0.6074 + 2493/T\\qquad for\\quad Fe\\\\ & \\log \\eta={-}0.5695 + 2157/T\\qquad for\\quad Ni \\\\ & \\log \\eta={-}0.6620 + 2430/T\\qquad for\\quad Co.} The isothermal viscosities of Fe-Ni and Fe-Co binary melts increase monotonically with increasing Fe content. On the other hand, in Ni-Co binary melt, the isothermal viscosity decreases slightly and then increases with increasing Co. The activation energy of Fe-Co binary melt increased slightly on mixing, and those of Fe-Ni and Ni-Co melts decreased monotonically with increasing Ni content. The above behaviour is discussed based on the thermodynamic properties of the alloys.

  11. Processing of glass-ceramics from lunar resources

    NASA Technical Reports Server (NTRS)

    Fabes, B. D.; Poisl, W. H.

    1991-01-01

    The goal is to fabricate useful ceramic materials from the by-products of lunar oxygen production processes. Specifically, the crystal nucleation and growth kinetics of ilmenite-extracted lunar regolith were studied in order to produce glass-ceramics with optimal mechanical, thermal, and abrasion resistant properties. In the initial year of the program, construction and calibration of a high temperature viscometer, used for determining the viscosity of simulated lunar glasses was finished. A series of lunar simulants were also prepared, and the viscosity of each was determined over a range of temperatures. It was found that an increase in the concentration of Fe2O3 decreases the viscosity of the glass. While this may be helpful in processing the glass, Fe2O3 concentrations greater than approximately 10 wt percent resulted in uncontrolled crystallization during viscosity measurements. Impurities (such as Na2O, MnO, and K2O) in the regolith appeared to decrease the viscosity of the parent glass. These effects, as well as those of TiO2 and SiO2 on the processability of the glass, however, remain to be quantified.

  12. Methods of viscosity measurements in sealed ampoules

    NASA Astrophysics Data System (ADS)

    Mazuruk, Konstantin

    1999-07-01

    Viscosity of semiconductors and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviate. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and nonintrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods is presented along with the initial test result of the constructed apparatus. Advantages of each of the method are discussed.

  13. Debris flow rheology: Experimental analysis of fine-grained slurries

    USGS Publications Warehouse

    Major, Jon J.; Pierson, Thomas C.

    1992-01-01

    The rheology of slurries consisting of ≤2-mm sediment from a natural debris flow deposit was measured using a wide-gap concentric-cylinder viscometer. The influence of sediment concentration and size and distribution of grains on the bulk rheological behavior of the slurries was evaluated at concentrations ranging from 0.44 to 0.66. The slurries exhibit diverse rheological behavior. At shear rates above 5 s−1 the behavior approaches that of a Bingham material; below 5 s−1, sand exerts more influence and slurry behavior deviates from the Bingham idealization. Sand grain interactions dominate the mechanical behavior when sand concentration exceeds 0.2; transient fluctuations in measured torque, time-dependent decay of torque, and hysteresis effects are observed. Grain rubbing, interlocking, and collision cause changes in packing density, particle distribution, grain orientation, and formation and destruction of grain clusters, which may explain the observed behavior. Yield strength and plastic viscosity exhibit order-of-magnitude variation when sediment concentration changes as little as 2–4%. Owing to these complexities, it is unlikely that debris flows can be characterized by a single rheological model.

  14. The rheology of water-methanol slurries: Implications for cryovolcanism on Titan

    NASA Astrophysics Data System (ADS)

    Mitchell, K. L.; Zhong, F.; Hays, C. C.; Choukroun, M.; Barmatz, M. B.; Kargel, J. S.

    2008-12-01

    Cassini SAR imagery has revealed the presence of landforms on the surface of Titan that may be cryovolcanic flows and domes [1,2]. In order to relate the observed surface features to the geological processes and chemistries that produced them, it is necessary to construct rheological flow models at cryogenic temperatures. We report preliminary cryogenic rheological measurements on a binary 40 wt% methanol-water composition, used as a path finding analog for characterizing the rheological properties of candidate cryo-magmas and eruptant materials [3]. Work by Kargel et al. [4] used a cryogenic rotational viscometer and a viscous drop experiment to determine the viscosity of ammonia-water slurries, a likely composition of Titan cryomagma. This work revealed that the materials in question have viscosities that were controlled by the pure liquid viscosity and the solid fraction, the latter also resulting in shear-rate dependence. Our cryogenic rheological measurements were conducted between 90-300 K using a home- built LN2 cooled cryogenic rotational viscometer system, with data acquisition and control achieved using the National Instruments LabView program. We report the results of a series of measurements performed as a function of temperature and rotational strain rate. The methanol-water mixture exhibited a variety of rheological response behaviors under these experimental conditions; i.e., development of yield stress-like behaviors, shear-rate dependence, and thixotropic behavior, even at relatively low crystal fractions, which to our knowledge have not been previously observed or reported. At fixed shear rate our data are fit well by the Andrade equation, with the activation energy modified by the solid volume fraction. At fixed temperature, depending on shearing history, a Cross model describes our data well over a wide shear rate range. A Bingham plastic model appears to be a good constitutive model for the data measured at high shear rates when the shear was global, but at low shear stresses the approximation becomes inaccurate because the Bingham yield stress is only an approximation to what is actually a high viscosity creep behavior. This yield-stress-like creep behavior implies that initialization of levees in cryolava flows is more likely than would be inferred from previous cryo-rheological studies and may provide a partial explanation for features observed by the Cassini spacecraft on Titan, which are interpreted as steep-sided volcanic constructs [2]. This analysis will be critical in the development of future experiments designed to measure all the parameters controlling cryomagma rheologies for input into flow models. [1] Elachi et al. (2005) Science 308, 970-974. [2] Lopes et al. (2007) Icarus 186, 395-412. [3] Zhong et al. (in review) Icarus. [4] Kargel et al. (1991) Icarus 89, 93-11.

  15. Rheological properties of molten Kilauea Iki basalt containing suspended crystals. Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weed, H.C.; Ryerson, F.J.; Piwinskii, A.J.

    1984-01-01

    In order to model the flow behavior of molten silicate suspensions, such as magmas and slags, the rheological behavior must be known as a function of the concentration of suspended crystals, melt composition, and external conditions. We have determined the viscosity and crystallization sequence for a Kilauea Iki basalt between 1250/sup 0/C and 1149/sup 0/C at 100 kPa total pressure and fO/sub 2/ corresponding to the quartz-fayalite-magnetite buffer in an iron-saturated Pt30Rh rotating cup viscometer of the Couette type. The apparent viscosity varies from 9 to 879 Pa.s. The concentration of suspended cyrstals varies from 18 volume percent at 1250/supmore » 0/C to 59 volume percent at 1149/sup 0/C. The molten silicate suspension shows power-law behavior: log tau yx = A/sub 0/ + A/sub 1/ log du/dx, where tau/sub yx/ is the shear stress and (du/dx) the shear rate. Since A/sub 1/ less than or equal to 1, the apparent viscosity decreases with increasing shear rate and the system is pseudoplastic. 15 refs., 4 figs., 5 tabs.« less

  16. Yield Stress Model for Molten Composition B-3

    NASA Astrophysics Data System (ADS)

    Davis, Stephen; Zerkle, David

    2017-06-01

    Composition B-3 (Comp B-3) is a melt-castable explosive composed of 60/40 wt% RDX/TNT (hexahydro-1,3,5-trinitro-1,3,5-triazine/2,4,6-trinitrotoluene). During casting operations thermal conditions are controlled which along with the low melting point of TNT and the insensitivity of the mixture to external stimuli leading to safe use. Outside these standard operating conditions a more rigorous model of Comp B-3 rheological properties is necessary to model thermal transport as Comp B-3 evolves from quiescent solid through vaporization/decomposition upon heating. One particular rheological phenomena of interest is Bingham plasticity, where a material behaves as a quiescent solid unless a sufficient load is applied, resulting in fluid flow. In this study falling ball viscometer data is used to model the change in Bingham plastic yield stresses as a function of RDX particle volume fraction; a function of temperature. Results show the yield stress of Comp B-3 (τy) follows the expression τy = B ϕ -ϕc N , where Φ and Φc are the volume fraction of RDX and a critical volume fraction, respectively and B and N are experimentally evaluated constants.

  17. Synthesis and characterization of poly(lactic acid)/ montmorillonite nanocomposites by in situ polycondensation catalyzed by non-metal-based compound.

    PubMed

    Kaewprapan, Kulwadee; Phattanarudee, Siriwan

    2012-01-01

    Poly(lactic acid)/montmorillonite nanocomposites were prepared by using non-toxic catalysts, i.e., phthalic acid and succinimide, via in situ polycondensation in presence of silicate. Concentrations of catalysts and clay were varied in a range of 0-3% wt and 0-0.5% wt, respectively. The reaction condition was controlled at 180 degrees C for 24 hr under a reduced pressure. Viscosity average molecular weight of the synthesized polymers and nanocomposites were characterized and compared using an Ubbelohde viscometer. Pattern of silicate distribution in the composites was investigated by X-ray diffraction to correlate with thermal properties evaluated by differential scanning calorimetry and thermogravimetric analysis. The results showed that the addition of catalysts at 2% wt gave the highest product yield (55-60%). The presence of silicate affected on molecular weight reduction, and the diffracted patterns suggested an intercalated structure. With a small amount of added filler, a significant improvement in thermal property and crystallinity of the resultant composites was obtained compared to those of the catalyzed polymers, in which the composites with succinimide exhibited overall better thermal stability and higher crystallinity than the ones prepared with phthalic acid.

  18. High intensity 5 eV atomic oxygen source and Low Earth Orbit (LEO) simulation facility

    NASA Technical Reports Server (NTRS)

    Cross, J. B.; Spangler, L. H.; Hoffbauer, M. A.; Archuleta, F. A.; Leger, Lubert; Visentine, James

    1987-01-01

    An atomic oxygen exposure facility has been developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in LEO. The studies that are being undertaken using the facility will provide: absolute reaction cross sections for use in engineering design problems; formulations of reaction mechanisms; and calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in LEO to ground based investigations. The facility consists of: (1) a CW laser sustained discharge source of O atoms having a variable energy up to 5 eV and an intensity between 10(15) and 10(17) O atoms s(-1) cm(-2); (2) an atomic beam formation and diagnostics system consisting of various stages of differential pumping, a mass spectrometer detector, and a time of flight analyzer; (3) a spinning rotor viscometer for absolute O atom flux measurements; and (4) provision for using the system for calibration of actual flight instruments. Surface analysis equipment is available for the characterization of material surfaces before and after exposure to O atoms.

  19. Synthesis of flower-like BaTiO3/Fe3O4 hierarchically structured particles and their electrorheological and magnetic properties.

    PubMed

    Wang, Baoxiang; Yin, Yichao; Liu, Chenjie; Yu, Shoushan; Chen, Kezheng

    2013-07-21

    Flower-like BaTiO3/Fe3O4 hierarchically structured particles composed of nano-scale structures on micro-scale materials were synthesized by a simple solvothermal approach and characterized by the means of X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), magnetic testing and rotary viscometer. The influences on the morphology and structure of solvothermal times, type and amount of surfactant, EG : H2O ratio, etc. were studied. Magnetic testing results show that the samples have strong magnetism and they exhibit superparamagnetic behavior, as evidenced by no coercivity and the remanence at room temperature, due to their very small sizes, observed on the M-H loop. The saturation magnetization (M(s)) value can achieve 18.3 emu g(-1). The electrorheological (ER) effect was investigated using a suspension of the flower-like BaTiO3/Fe3O4 hierarchically structured particles dispersed in silicone oil. We can observe a slight shear-thinning behavior of shear viscosity at a low shear rate region even at zero applied electric field and a Newtonian fluid behavior at high shear rate regions.

  20. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    NASA Astrophysics Data System (ADS)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  1. High-Temperature Viscosity Of Commercial Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hrma, Pavel R; See, Clem A; Lam, Oanh P

    2005-01-01

    Viscosity was measured for six types of commercial glasses: low-expansion-borosilicate glasses, E glasses, fiberglass wool glasses, TV panel glasses, container glasses, and float glasses. Viscosity data were obtained with rotating spindle viscometers within the temperature range between 900°C and 1550°C; the viscosity varied from 1 Pa∙s to 750 Pa∙s. Arrhenius coefficients were calculated for individual glasses and linear models were applied to relate them to the mass fractions of 11 major components (SiO2, CaO, Na2O, Al2O3, B2O3, BaO, SrO, K2O, MgO, PbO, and ZrO2) and 12 minor components (Fe2O3, ZnO, Li2O, TiO2, CeO2, F, Sb2O3, Cr2O3, As2O3, MnO2, SO3, andmore » Co3O4). The models are recommended for glasses containing 42 to 84 mass% SiO2 to estimate viscosities or temperatures at a constant viscosity for melts within both the temperature range from 1100°C to 1550°C and viscosity range from 10 to 400 Pas.« less

  2. Magnetically driven, acoustically tracked, translating-ball rheometer for small, opaque samples

    NASA Astrophysics Data System (ADS)

    Tran-Son-Tay, R.; Beaty, B. B.; Acker, D. N.; Hochmuth, R. M.

    1988-08-01

    A new rheometer has been designed to measure the rheological properties at low Reynolds number of microliter quantities of opaque suspensions. The rheometer uses a falling-ball technique to measure steady-state viscosity and a vertically oscillating, magnetically driven ball for viscoelastic measurements. The motion of the ball is tracked by ultrasound echo location, in which sound waves are transmitted and received by an ultrasound transducer mounted at the base of the tube. Concentrated suspensions of red blood cells are used as opaque test samples. The results obtained are in good agreement with those reported in the literature. The data confirm the fact that a concentrated suspension of red blood cells behaves as a shear thinning material and that the energy stored by the suspension during an oscillatory cycle increases with frequency. Testing of the rheometer is also made by using a Newtonian silicone oil. Viscosity measurements obtained with both the falling- and oscillating-ball methods are consistent and are within 2% of the value of 47.3±0.5 cP given by the Cannon-Fenske viscometer. However, it is found that the oscillating-ball technique gives the largest standard deviation, 6%, as opposed to 2% for the falling-ball technique.

  3. Determination and evaluation of the thermophysical properties of an alkali carbonate eutectic molten salt.

    PubMed

    An, Xuehui; Cheng, Jinhui; Zhang, Peng; Tang, Zhongfeng; Wang, Jianqiang

    2016-08-15

    The thermal physical properties of Li2CO3-Na2CO3-K2CO3 eutectic molten salt were comprehensively investigated. It was found that the liquid salt can remain stable up to 658 °C (the onset temperature of decomposition) by thermal analysis, and so the investigations on its thermal physical parameters were undertaken from room temperature to 658 °C. The density was determined using a self-developed device, with an uncertainty of ±0.00712 g cm(-3). A cooling curve was obtained from the instrument, giving the liquidus temperature. For the first time, we report the obtainment of the thermal diffusivity using a laser flash method based on a special crucible design and establishment of a specific sample preparation method. Furthermore, the specific heat capacity was also obtained by use of DSC, and combined with thermal diffusivity and density, was used to calculate the thermal conductivity. We additionally built a rotating viscometer with high precision in order to determine the molten salt viscosity. All of these parameters play an important part in the energy storage and transfer calculation and safety evaluation for a system.

  4. Rheological assessment of nanofluids at high pressure high temperature

    NASA Astrophysics Data System (ADS)

    Kanjirakat, Anoop; Sadr, Reza

    2013-11-01

    High pressure high temperature (HPHT) fluids are commonly encountered in industry, for example in cooling and/or lubrications applications. Nanofluids, engineered suspensions of nano-sized particles dispersed in a base fluid, have shown prospective as industrial cooling fluids due to their enhanced rheological and heat transfer properties. Nanofluids can be potentially utilized in oil industry for drilling fluids and for high pressure water jet cooling/lubrication in machining. In present work rheological characteristics of oil based nanofluids are investigated at HPHT condition. Nanofluids used in this study are prepared by dispersing commercially available SiO2 nanoparticles (~20 nm) in a mineral oil. The basefluid and nanofluids with two concentrations, namely 1%, and 2%, by volume, are considered in this investigation. The rheological characteristics of base fluid and the nanofluids are measured using an industrial HPHT viscometer. Viscosity values of the nanofluids are measured at pressures of 100 kPa to 42 MPa and temperatures ranging from 25°C to 140°C. The viscosity values of both nanofluids as well as basefluid are observed to have increased with the increase in pressure. Funded by Qatar National Research Fund (NPRP 08-574-2-239).

  5. Modeling and measuring non-Newtonian shear flows of soft interfaces

    NASA Astrophysics Data System (ADS)

    Lopez, Juan; Raghunandan, Aditya; Underhill, Patrick; Hirsa, Amir

    2017-11-01

    Soft interfaces of polymers, particles, and proteins between fluid phases are ubiquitous in industrial and natural processes. The flow response of such systems to deformation is often not linear, as one would expect for Newtonian interfaces. The resistance to (pure shear) flow of interfaces is generally characterized by a single intrinsic material property, the surface shear viscosity. Predicted shear responses of Newtonian interfaces have achieved consensus across a wide range of flow conditions and measurement devices, when the nonlinear hydrodynamic coupling to the bulk phase is correctly accounted for. However, predicting the flows of sheared non-Newtonian interfaces remains a challenge. Here, we introduce a computational model that incorporates a non-Newtonian constitutive equation for the sheared interface and properly accounts for the coupled interfacial and bulk phase flows. We compare predictions to experiments performed with a model phospholipid system, DPPC - the main constituent of mammalian lung surfactant. Densely packed films of DPPC are directly sheared in a knife-edge surface viscometer. Yield-stress and shear thinning behaviors are shown to be accurately captured across hydrodynamic regimes straddling the Stokes flow limit to inertia dominated flows. Supported by NASA Grant NNX13AQ22G.

  6. First haemorheological experiment on NASA space shuttle 'Discovery' STS 51-C: aggregation of red cells.

    PubMed

    Dintenfass, L; Osman, P D; Jedrzejczyk, H

    1985-01-01

    The 'secret' D.O.D. Mission on flight STS 51-C also carried nearly 100 kg of automated instrumentation of the Australian experiment on aggregation of red cells ("ARC"). The automated Slit-Capillary Photo Viscometer contained blood samples from subjects with history of coronary heart disease, cancer of the colon, insulin-dependent diabetes, etc., as well as normals. The experiment ran for nine hours, according to the program of its microcomputers. When shuttle landed and instrumentation recovered and opened in the presence of NASA quality control officers, it was obvious that experiment was a success. Tentative and preliminary results can be summarized as follows: red cells did not change shape under zero gravity; red cells do aggregate under zero gravity, although the size of aggregates is smaller than on the ground; the morphology of aggregates of red cells appears to be of rouleaux type under zero gravity, notwithstanding the fact that pathological blood was used. These results will have to be confirmed in the future flights. The background and history of development of the project are described, and put into context of our general haemorheological studies.

  7. Modeling of photodegradation in solar cell modules of substrate and superstrate design made with ethylene-vinyl acetate as pottant material

    NASA Technical Reports Server (NTRS)

    Somersall, A. C.; Guillet, J. E.

    1981-01-01

    The rates of hydrogen abstraction by peroxy radicals were proven to be too slow for significant oxidation of the alkane substrate to be important. The numerical procedure, independent of our particular data base was verified by reproducing concentration time profiles for a model reaction set describing the cesium flare system in the upper atmosphere. Simulation was identical to that given in the literature. Experimental verification of the data base is to be attempted by weatherometry studies in the coming year. Work on the new diagnostic techniques was completed. The adapted automated viscometer was demonstrated to be an efficient and reliable tool for routine measurements of viscosity (molecular weight) changes in solid samples after batch solutions have been made up. The laser photolysis GC method for monitoring extremely low levels of oxidation in polymers proved to be impractical because the yields of carbon monoxide were too low for quantification. Much progress was made with the computer model. The reaction matrix was completely revised, resulting in a new scheme of 31 reactions and time, lifetimes in excess of ten years. The results to date lead us to some tentative observations.

  8. Hereditary Xerocytosis Revisited

    PubMed Central

    Archer, Natasha; Shmukler, Boris E.; Andolfo, Immacolata; Vandorpe, David H.; Gnanasambandam, Radhakrishnan; Higgins, John M.; Rivera, Alicia; Fleming, Mark D.; Sachs, Frederick; Gottlieb, Philip A.; Iolascon, Achille; Brugnara, Carlo; Alper, Seth L.; Nathan, David G.

    2014-01-01

    A 21 year old male student presented in 1980 as an Olympic athlete with a 12 year history of jaundice, pallor, and darkened urine induced by the atraumatic exercise of swimming (1). Physical examination at that time was remarkable only for moderate scleral icterus without hepatosplenomegaly. Hematological examination revealed moderate macrocytosis (MCV 102 fL) without anemia (Hct 50%, Hb 17 g/dL, 9% reticulocytes). The peripheral blood smear showed occasional target cells. Red cell osmotic fragility was decreased. Red cell Na content was increased and K content was decreased, with reduced total monovalent ion content. Passive red cell permeability of both Na and K were increased. A supervised 2.5 hr swimming workout increased free plasma Hb from <5 to 45 mg/dL and decreased serum haptoglobin from 25 to 6 mg/dL. The post-exercise urine sediment was remarkable for hemosiderin-laden tubular epithelial cells, without frank hemoglobinuria. The circulating 15 day erythrocyte half-life measured after 6 days without exercise was further shortened to 12 days after resumption of twice-per-day swimming workouts for 1 week. The patient’s red cells were hypersensitive to in vitro shear stress applied by cone-plate viscometer. PMID:25044010

  9. Optimal haematocrit in subjects with normal haemoglobin genotype (HbAA), sickle cell trait (HbAS), and homozygous sickle cell disease (HbSS).

    PubMed

    Bowers, A S; Pepple, D J; Reid, H L

    2011-01-01

    The determination of an optimal haematocrit (H0) has important clinical implications if such a level can be attained, and more importantly, maintained. This is defined as a haematocrit level, above or below which oxygen delivery is deleteriously affected. This study is designed to determine an optimal haematocrit in normal (AA), sickle cell trait (AS) and sickle cell disease (SS) subjects. Twenty-seven apparently healthy subjects having normal haemoglobin genotype, 24 with sickle cell trait and 42 with homozygous sickle cell disease were recruited into the study. Whole blood viscosity (WBV) was measured by a Wells Brookfield Cone and Plate Viscometer at a shear rate of 230 sec-1. Haematocrit was determined by an AC.Tron Coulter Counter. The optimal haematocrit was calculated as the inverse of a constant, K, which was derived from the haematocrit and viscosity data. Our findings showed that the H0 varied significantly among the 3 haemoglobin genotypes, in the order AA vs SS and AS vs SS. Additionally, the data indicated an increased H0 in subjects with sickle cell trait, suggesting a possible impairment in oxygen delivery in these individuals.

  10. A study on rheological characteristics of roller milled fenugreek fractions.

    PubMed

    Sakhare, Suresh D; Inamdar, Aashitosh A; Prabhasankar, P

    2016-01-01

    Fenugreek seeds were fractionated by roller milling to get various fractions. The roller milled fractions and whole fenugreek flour (WFF) were evaluated for the flow behavior and time-dependent flow properties using a rotational viscometer at the temperatures of 10-60 (0)C. The samples subjected to a programmed shear rate increase linearly from 0 to 300 s(-1) in 3 min and successive decrease linearly shear rate from 300 s(-1) to 0 in 3 min. The roller milled fractions and WFF paste exhibited non-Newtonian pseudoplastic behavior. Difference in hysteresis loop area was observed among the roller milled fractions and WFF, being more noticeable at lower temperatures. Power law and Casson models were used to predict flow properties of samples. The power law model described well the flow behavior of the roller milled fractions and WFF at temperatures tested. Except flour (FL) fraction, consistency coefficient, m, increased with the temperature both in the forward and backward measurements. The roller milled fractions and WFF exhibited rheopectic behavior that increased viscosity with increasing the shear speed and the temperature. For all the sample tested, initial shear stress increased with increase in shear rate and temperature.

  11. Methods of Viscosity Measurements in Sealed Ampoules

    NASA Technical Reports Server (NTRS)

    Mazuruk, Konstantin

    1999-01-01

    Viscosity of semiconductor and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviated. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution (0.05 arc.sec) angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and non intrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield the viscosity of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods (oscillating cup, transient torque, and resonance) is presented along with the initial test results of the constructed apparatus. Advantages of each of the method are discussed.

  12. E-selectin liposomal and nanotube-targeted delivery of doxorubicin to circulating tumor cells

    PubMed Central

    Mitchell, Michael J.; Chen, Christina S.; Ponmudi, Varun; Hughes, Andrew D.; King, Michael R.

    2012-01-01

    The presence of circulating tumor cells (CTCs) is believed to lead to the formation of secondary tumors via an adhesion cascade involving interaction between adhesion receptors of endothelial cells and ligands on CTCs. Many CTCs express sialylated carbohydrate ligands on their surfaces that adhere to selectin protein found on inflamed endothelial cells. We have investigated the feasibility of using immobilized selectin proteins as a targeting mechanism for CTCs under flow. Herein, targeted liposomal doxorubicin (L-DXR) was functionalized with recombinant human E-selectin (ES) and polyethylene glycol (PEG) to target and kill cancer cells under shear flow, both when immobilized along a microtube device or sheared in a cone-and-plate viscometer in a dilute suspension. Healthy circulating cells such as red blood cells were not targeted by this mechanism and were left to freely circulate, and minimal leukocyte death was observed. Halloysite nanotube (HNT)-coated microtube devices immobilized with nanoscale liposomes significantly enhanced the targeting, capture, and killing of cancer cells. This work demonstrates that E-selectin functionalized L-DXR, sheared in suspension or immobilized onto microtube devices, provides a novel approach to selectively target and deliver chemotherapeutics to CTCs in the bloodstream. PMID:22421423

  13. Final Research Performance Report - Small Molecular Associative Carbon Dioxide (CO 2) Thickeners for Improved Mobility Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enick, Robert M.

    The initial objective of this project was to promote the application of a CO 2 thickener for improved mobility control during CO 2 EOR based on solubility tests, viscosity tests, and core floods. Ultimately, it was demonstrated that the CO 2-soluble polymeric thickeners are much better suited for use a CO 2-soluble conformance control agents for diverting the flow of CO 2 away from thief zones. Our team generated several effective small molecule CO 2 thickeners with ARPA-e funding. Unfortunately, none of these small molecule thickeners could dissolve in CO 2 without the addition of unacceptably large amounts of hexanemore » or toluene as a co-solvent Therefore none were viable candidates for the core flooding studies associated with NETL award. Therefore during the entire core flood testing program associated with this NETL award, our team used only the most promising polymeric CO 2 thickener, a polyfluoroacrylate (PFA). In order to produce an environmentally benign polymer, the monomer used to make the new polymers used in this study was a fluoroacrylate that contains only six fluorinated carbons. We verified CO 2 solubility with a phase behavior cell. The thickening potential of all polymer samples was substantiated with a falling ball viscometer and a falling cylinder viscometer at Pitt. Two different viscometers were used to determine the increase in CO 2 viscosity that could be achieved via the dissolution of PFA. Praxair, which has an interest in thickening CO 2 for pilot EOR projects and for waterless hydraulic fracturing, agreed to measure the viscosity of CO 2-PFA solutions at no cost to the project. Falling cylinder viscometery was conducted at Pitt in our windowed high pressure phase behavior cell. Both apparatuses indicated that at very low shear rates the CO 2 viscosity increased by a factor of roughly 3.5 when 1wt% PFA was dissolved in the CO 22. Our team also planned thickener concentrations and compositions at Pitt for the core tests that were conducted at Special Core Analysis Laboratories, Inc., (SCAL) in Midland, TX, where the ability for PFA to reduce CO 2 mobility in a core was then tested. During the beginning of these tests, the PFA polymer was then shown to impart reasonable improvements in mobility control during the SCAL core tests; as the CO 2-PFA solution displaced CO 2 from the core at a constant volumetric flow rate, the pressure drop increased as expected. However, as the test progressed, there was clear and surprising evidence of dramatic reductions in core permeability due to PFA adsorption, especially for sandstones. For example, as the CO 2-PFA solution displaced pure CO 2 from sandstone and limestone cores, the pressure drop increased by factors of multiple hundreds to over a thousand. It was subsequently demonstrated that the PFA injected into the core either (a) adsorbed strongly and irreversibly onto the rock surfaces, (b) deposited/precipitated within the rock, thereby blocking pores in a manner that could be dislodged by large changes in flow rate or flow direction, or (c) remained in solution and passed completely through the core. The loss of PFA to the porous media and the unacceptably large increases in pressure drop both indicated that PFA was inappropriate for CO 2 EOR mobility control, where thickener adsorption must be minimized and mobility reductions of only 10-100-fold are typically required. However, we realized that because the CO 2-PFA solution could greatly reduce the permeability of porous media, it could serve as a near wellbore conformance control agent for blocking “thief zones”, where adsorption is acceptable and dramatic increases in pressure drop are desirable. These effects were more dramatic for sandstone than for limestone. Therefore, these PFA fluoroacrylate polymers can serve as a CO 2-soluble conformance control agent for CO 2-EOR, especially in sandstone formations. This injection of a single phase solution of CO 2-PFA for permeability reduction is (to the best of our knowledge) the first report of a CO 2-soluble conformance control additive. We also demonstrated that the optimal strategy for using CO 2-PFA solutions for conformance control is analogous to the application of water-based polymeric gels; the CO 2-PFA solution should first be injected only in an isolated thief zone to induce dramatic reductions in permeability only in that thief zone, and then CO 2 should be injected into all of the zones. Finally, it was noted that given the propensity of PFA to adsorb onto sandstone, the adsorption of PFA from CO 2-PFA solutions onto cement surfaces promote the sealing of extremely fine cracks in casing cement.« less

  14. Development of environmental friendly lost circulation material from banana peel

    NASA Astrophysics Data System (ADS)

    Sauki, Arina; Hasan, Nur â.€˜Izzati; Naimi, Fardelen Binti Md; Othman, Nur Hidayati

    2017-12-01

    Loss of expensive mud could lead to major financial problem in executing a drilling project and is one of the biggest problems that need to be tackled during drilling. Synthetic Based Mud (SBM) is the most stable state of the art drilling mud used in current drilling technologies. However, the problem with lost circulation is still inevitable. The focus of this project is to develop a new potential waste material from banana peel in order to combat lost circulation in SBM. Standard industrial Lost Circulation Material (LCM) is used to compare the performance of banana peel as LCM in SBM. The effects of different sizing of banana peels (600 micron, 300 micron and 100 micron) were studied on the rheological and filtration properties of SBM and the bridging performance of banana peel as LCM additive. The tests were conducted using viscometer, HTHP filter press and sand bed tester. Thermal analysis of banana peel was also studied using TGA. According to the results obtained, 300 and 100 micron size of banana peel LCM exhibited an improved bridging performance by 65% as compared to industrial LCM. However, banana peel LCM with the size of 600 micron failed to act as LCM due to the total invasion of mud into the sand bed.

  15. Highly stable liquid metal-based pressure sensor integrated with a microfluidic channel.

    PubMed

    Jung, Taekeon; Yang, Sung

    2015-05-21

    Pressure measurement is considered one of the key parameters in microfluidic systems. It has been widely used in various fields, such as in biology and biomedical fields. The electrical measurement method is the most widely investigated; however, it is unsuitable for microfluidic systems because of a complicated fabrication process and difficult integration. Moreover, it is generally damaged by large deflection. This paper proposes a thin-film-based pressure sensor that is free from these limitations, using a liquid metal called galinstan. The proposed pressure sensor is easily integrated into a microfluidic system using soft lithography because galinstan exists in a liquid phase at room temperature. We investigated the characteristics of the proposed pressure sensor by calibrating for a pressure range from 0 to 230 kPa (R2 > 0.98) using deionized water. Furthermore, the viscosity of various fluid samples was measured for a shear-rate range of 30-1000 s(-1). The results of Newtonian and non-Newtonian fluids were evaluated using a commercial viscometer and normalized difference was found to be less than 5.1% and 7.0%, respectively. The galinstan-based pressure sensor can be used in various microfluidic systems for long-term monitoring with high linearity, repeatability, and long-term stability.

  16. Experimental density measurements of bis(2-ethylhexyl) phthalate at elevated temperatures and pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bamgbade, Babatunde A; Wu, Yue; Baled, Hseen O

    2013-08-01

    Experimental high-temperature, high-pressure (HTHP) density data for bis(2-ethylhexyl) phthalate (DEHP) are reported in this study. DEHP is a popular choice as a reference fluid for viscosity calibrations in the HTHP region. However, reliable HTHP density values are needed for accurate viscosity calculations for certain viscometers (e.g. rolling ball). HTHP densities are determined at T = (373, 424, 476, 492, and 524) K and P to 270 MPa using a variable-volume, high-pressure view cell. The experimental density data are satisfactorily correlated by the modified Tait equation with a mean absolute percent deviation (δ) of 0.15. The experimental data are modeled withmore » the Peng–Robinson (PREoS), volume-translated PREoS (VT-PREoS), and perturbed chain statistical associating fluid theory (PC-SAFT EoS) models. The required parameters for the two PREoS and the PC-SAFT EoS models are determined using group contribution methods. The PC-SAFT EoS performs the best of the three models with a δ of 2.12. The PC-SAFT EoS is also fit to the experimental data to obtain a new set of pure component parameters that yield a δ of 0.20 for these HTHP conditions.« less

  17. Highly defined 3D printed chitosan scaffolds featuring improved cell growth.

    PubMed

    Elviri, Lisa; Foresti, Ruben; Bergonzi, Carlo; Zimetti, Francesca; Marchi, Cinzia; Bianchera, Annalisa; Bernini, Franco; Silvestri, Marco; Bettini, Ruggero

    2017-07-12

    The augmented demand for medical devices devoted to tissue regeneration and possessing a controlled micro-architecture means there is a need for industrial scale-up in the production of hydrogels. A new 3D printing technique was applied to the automation of a freeze-gelation method for the preparation of chitosan scaffolds with controlled porosity. For this aim, a dedicated 3D printer was built in-house: a preliminary effort has been necessary to explore the printing parameter space to optimize the printing results in terms of geometry, tolerances and mechanical properties of the product. Analysed parameters included viscosity of the starting chitosan solution, which was measured with a Brookfield viscometer, and temperature of deposition, which was determined by filming the process with a cryocooled sensor thermal camera. Optimized parameters were applied to the production of scaffolds from solutions of chitosan alone or with the addition of raffinose as a viscosity modifier. Resulting hydrogels were characterized in terms of morphology and porosity. In vitro cell culture studies comparing 3D printed scaffolds with their homologous produced by solution casting evidenced an improvement in biocompatibility deriving from the production technique as well as from the solid state modification of chitosan stemming from the addition of the viscosity modifier.

  18. Investigation of damping liquids for aircraft instruments

    NASA Technical Reports Server (NTRS)

    Keulegan, G H

    1929-01-01

    This report covers the results of an investigation carried on at the Bureau of Standards under a research authorization from, and with the financial assistance of, the National Advisory Committee for Aeronautics. The choice of a damping liquid for aircraft instruments is difficult owing to the range of temperature at which aircraft operate. Temperature changes affect the viscosity tremendously. The investigation was undertaken with the object of finding liquids of various viscosities otherwise suitable which had a minimum change in viscosity with temperature. The new data relate largely to solutions. The effect of temperature on the kinematic viscosity of the following liquids and solutions was determined in the temperature interval -18 degrees to +30 degrees C. (1) solutions of animal and vegetable oils in xylene. These were poppy-seed oil, two samples of neat's-foot oils, castor oil, and linseed oil. (2) solutions of mineral oil in xylene. These were Squibb's petrolatum of naphthene base and transformer oil. (3) glycerine solutions in ethyl alcohol and in mixture of 50-50 ethyl alcohol and water. (4) mixtures of normal butyl alcohol with methyl alcohol. (5) individual liquids, kerosene, mineral spirits, xylene, recoil oil. The apparatus consisted of four capillary-tube viscometers, which were immersed in a liquid bath in order to secure temperature control. The method of calibration and the related experimental data are presented.

  19. Ferrofluids based on Co-Fe-Si-B amorphous nanoparticles

    NASA Astrophysics Data System (ADS)

    Wang, Tianqi; Bian, Xiufang; Yang, Chuncheng; Zhao, Shuchun; Yu, Mengchun

    2017-03-01

    Magnetic Co-Fe-Si-B amorphous nanoparticles were successfully synthesized by chemical reduction method. ICP, XRD, DSC, and TEM were used to investigate the composition, structure and morphology of Co-Fe-Si-B samples. The results show that the Co-Fe-Si-B samples are amorphous, which consist of nearly spherical nanoparticles with an average particle size about 23 nm. VSM results manifest that the saturation magnetization (Ms) of Co-Fe-Si-B samples ranges from 46.37 to 62.89 emu/g. Two kinds of ferrofluids (FFs) were prepared by dispersing Co-Fe-Si-B amorphous nanoparticles and CoFe2O4 nanoparticles in kerosene and silicone oil, respectively. The magnetic properties, stability and viscosity of the FFs were investigated. The FFs with Co-Fe-Si-B samples have a higher Ms and lower coercivity (Hc) than FFs with CoFe2O4 sample. Under magnetic field, the silicone oil-based FFs exhibit high stability. The viscosity of FFs under different applied magnetic fields was measured by a rotational viscometer, indicating that FFs with Co-Fe-Si-B particles present relative strong response to an external magnetic field. The metal-boride amorphous alloy nanoparticles have potential applications in the preparation of magnetic fluids with good stability and good magnetoviscous properties.

  20. Hemorheological changes and characteristic parameters derived from whole blood viscometry in chronic heroin addicts.

    PubMed

    Antonova, N; Zvetkova, E; Ivanov, I; Savov, Y

    2008-01-01

    A group of 15 chronic opioid addicts (DA) with mean age 26.5+/-7.3 years was studied by means of a rotational Contraves Low Shear 30 viscometer and the results have been compared with a control group of 19 healthy subjects. It was found that the mean whole blood viscosity values of the investigated group of heroin abusers (n=15) were elevated compared to that of healthy persons (n=19) over the whole shear rate range and fell by more than ten orders of magnitude (Savov et al., 2006). The present investigation uses the coefficients of the models of Ostwald-de-Walle (power law) and Herschel-Bulkley law, which describe whole blood flow curves (tau-gamma) within the shear rates range from 10(-2) to 10(2) s(-1) and itself incorporate whole blood viscosity data in the entire shear rate range. A significant difference in the mean yield shear stress tau(0) values of the drug abusers' group compared to the controls was found. A strong positive linear correlation was determined between the parameters of RBC aggregation in the group of heroin addicts confirming our previous results (Ivanov and Antonova, 2005; Savov, Zvetkova et al., 2007; Savov, Antonova et al., 2007) for intensive RBC and platelet aggregation and morphological changes in DA group.

  1. Polysaccharides and Oligosaccharides Produced on Malvar Wines Elaborated with Torulaspora delbrueckii CLI 918 and Saccharomyces cerevisiae CLI 889 Native Yeasts from D.O. "Vinos de Madrid".

    PubMed

    García, Margarita; Apolinar-Valiente, Rafael; Williams, Pascale; Esteve-Zarzoso, Braulio; Arroyo, Teresa; Crespo, Julia; Doco, Thierry

    2017-08-09

    Polysaccharides and oligosaccharides released into Malvar white wines elaborated through pure, mixed, and sequential cultures with Torulaspora delbrueckii CLI 918 and Saccharomyces cerevisiae CLI 889 native yeasts from D.O. "Vinos de Madrid" were studied. Both fractions from different white wines were separated by high-resolution size-exclusion chromatography. Glycosyl composition and wine polysaccharide linkages were determined by GC-EI-MS chromatography. Molar-mass distributions were determined by SEC-MALLS, and intrinsic viscosity was determined by differential viscometer. Yeast species and type of inoculation have a significant impact on wine carbohydrate composition and structure. Mannose residues from mannoproteins were significantly predominant in those cultures where T. delbrueckii was present in the fermentation process in comparison with when pure cultures of S. cerevisiae were present in the fermenation process. Galactose residues from polysaccharides rich in arabinose and galactose presented greater values in pure cultures of S. cerevisiae, indicating that S. cerevisiae released fewer mannoproteins than T. delbrueckii. Moreover, we reported structural differences between mannoproteins released by T. delbrueckii CLI 918 and those released by S. cerevisiae CLI 889. These findings help to provide important information about the polysaccharides and oligosaccharides released from the cell walls of Malvar grapes and the carbohydrates released from each yeast species.

  2. A comparison of simple rheological parameters and simulation data for Zymomonas mobilis fermentation broths with high substrate loading in a 3-L bioreactor.

    PubMed

    Um, Byung-Hwan; Hanley, Thomas R

    2008-03-01

    Traditionally, as much as 80% or more of an ethanol fermentation broth is water that must be removed. This mixture is not only costly to separate but also produces a large aqueous stream that must then be disposed of or recycled. Integrative approaches to water reduction include increasing the biomass concentration during fermentation. In this paper, experimental results are presented for the rheological behavior of high-solids enzymatic cellulose hydrolysis and ethanol fermentation for biomass conversion using Solka Floc as the model feedstock. The experimental determination of the viscosity, shear stress, and shear rate relationships of the 10 to 20% slurry concentrations with constant enzyme concentrations are performed with a variable speed rotational viscometer (2.0 to 200 rpm) at 40 degrees C. The viscosities of enzymatic suspension observed were in range of 0.0418 to 0.0144, 0.233 to 0.0348, and 0.292 to 0.0447 Pa s for shear rates up to 100 reciprocal seconds at 10, 15, and 20% initial solids (w/v), respectively. Computational fluid dynamics analysis of bioreactor mixing demonstrates the change in bioreactor mixing with increasing biomass concentration. The portion-loading method is shown to be effective for processing high-solids slurries.

  3. A Comparison of Simple Rheological Parameters and Simulation Data for Zymomonas mobilis Fermentation Broths with High Substrate Loading in a 3-L Bioreactor

    NASA Astrophysics Data System (ADS)

    Um, Byung-Hwan; Hanley, Thomas R.

    Traditionally, as much as 80% or more of an ethanol fermentation broth is water that must be removed. This mixture is not only costly to separate but also produces a large aqueous stream that must then be disposed of or recycled. Integrative approaches to water reduction include increasing the biomass concentration during fermentation. In this paper, experimental results are presented for the rheological behavior of high-solids enzymatic cellulose hydrolysis and ethanol fermentation for biomass conversion using Solka Floc as the model feedstock. The experimental determination of the viscosity, shear stress, and shear rate relationships of the 10 to 20% slurry concentrations with constant enzyme concentrations are performed with a variable speed rotational viscometer (2.0 to 200 rpm) at 40 °C. The viscosities of enzymatic suspension observed were in range of 0.0418 to 0.0144, 0.233 to 0.0348, and 0.292 to 0.0447 Pa s for shear rates up to 100 reciprocal seconds at 10, 15, and 20% initial solids (w/v), respectively. Computational fluid dynamics analysis of bioreactor mixing demonstrates the change in bioreactor mixing with increasing biomass concentration. The portion-loading method is shown to be effective for processing highsolids slurries.

  4. Highly Stable Liquid Metal-Based Pressure Sensor Integrated with a Microfluidic Channel

    PubMed Central

    Jung, Taekeon; Yang, Sung

    2015-01-01

    Pressure measurement is considered one of the key parameters in microfluidic systems. It has been widely used in various fields, such as in biology and biomedical fields. The electrical measurement method is the most widely investigated; however, it is unsuitable for microfluidic systems because of a complicated fabrication process and difficult integration. Moreover, it is generally damaged by large deflection. This paper proposes a thin-film-based pressure sensor that is free from these limitations, using a liquid metal called galinstan. The proposed pressure sensor is easily integrated into a microfluidic system using soft lithography because galinstan exists in a liquid phase at room temperature. We investigated the characteristics of the proposed pressure sensor by calibrating for a pressure range from 0 to 230 kPa (R2 > 0.98) using deionized water. Furthermore, the viscosity of various fluid samples was measured for a shear-rate range of 30–1000 s−1. The results of Newtonian and non-Newtonian fluids were evaluated using a commercial viscometer and normalized difference was found to be less than 5.1% and 7.0%, respectively. The galinstan-based pressure sensor can be used in various microfluidic systems for long-term monitoring with high linearity, repeatability, and long-term stability. PMID:26007732

  5. A Parallel-Plate Flow Chamber for Mechanical Characterization of Endothelial Cells Exposed to Laminar Shear Stress

    PubMed Central

    Wong, Andrew K.; LLanos, Pierre; Boroda, Nickolas; Rosenberg, Seth R.; Rabbany, Sina Y.

    2017-01-01

    Shear stresses induced by laminar fluid flow are essential to properly recapitulate the physiological microenvironment experienced by endothelial cells (ECs). ECs respond to these stresses via mechanotransduction by modulating their phenotype and biomechanical characteristics, which can be characterized by Atomic Force Microscopy (AFM). Parallel Plate Flow Chambers (PPFCs) apply unidirectional laminar fluid flow to EC monolayers in vitro. Since ECs in sealed PPFCs are inaccessible to AFM probes, cone-and-plate viscometers (CPs) are commonly used to apply shear stress. This paper presents a comparison of the efficacies of both methods. Computational Fluid Dynamic simulation and validation testing using EC responses as a metric have indicated limitations in the use of CPs to apply laminar shear stress. Monolayers subjected to laminar fluid flow in a PPFC respond by increasing cortical stiffness, elongating, and aligning filamentous actin in the direction of fluid flow to a greater extent than CP devices. Limitations using CP devices to provide laminar flow across an EC monolayer suggest they are better suited when studying EC response for disturbed flow conditions. PPFC platforms allow for exposure of ECs to laminar fluid flow conditions, recapitulating cellular biomechanical behaviors, whereas CP platforms allow for mechanical characterization of ECs under secondary flow. PMID:28989541

  6. Report on data requirements and hardware selection for in-situ ball viscometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepard, C.L.

    1994-12-01

    The in-situ ball rheometer is designed to provide data concerning the rheological properties of the waste contained in tank 101-SY. It is imperative that the data collected and the results obtained are useful to the community presently concerned with the mitigation of the waste contained within this tank. To ensure that this objective is met, discussions were held with representatives of different groups in order to determine their data needs. This report is a synopsis of these discussions. Four separate groups were identified as potential users of the data. Persons contacted included Don Trent (Pacific Northwest Laboratory (PNL)), who ismore » involved with Tempest modeling of the tank; Randy Marlow and John Strehlow (Westinghouse Hanford Company (WHC)), involved with structural analysis of the tank; Kemal Pasamehmetoglu and Cetin Unal (Los Alamos National Laboratory (LANL)), who are concerned with the safety analysis of activities performed within the tank; and Judith Bamberger, Paul Scott, and Gita Golcar (PNL) who are involved with the eventual retrieval of waste from the tank. Very specific questions were asked of these groups, including: From where in the tank are data needed? When should data be collected? In what manner are the data useful? What is the required accuracy of the data? Responses from each group are given.« less

  7. Substitute fluid examinations for liquid manure

    NASA Astrophysics Data System (ADS)

    Schrader, Kevin; Riedel, Marco; Eichert, Helmut

    For the farming industry it is essential to use liquid manure as natural fertilizer. Through new agricultural regulation 2015 in Germany the industry must develop new liquid manure spreader systems because the ammonia and methane emission are limited. In a research project the University of Applied Sciences Zwickau and some other industry partners will develop such a new innovative liquid manure spreader. The new liquid manure spreader should use pulsating air to distribute the liquid manure exactly. The pulsating air, which flows through the pipelines, should be analysed at a test station. For examinations at this test station it is important to find another substitute fluid because liquid manure smells strong, is not transparent and is also not homogeneous enough for scientific investigations. Furthermore it is important to ensure that the substitute fluid is, like liquid manure, a non-Newtonian fluid. The substitute fluid must be a shear-thinning substance - this means the viscosity decrease at higher shear rate. Many different samples like soap-water-farragoes, jelly-water-farragoes, agar-water-farragoes, soap-ethanol-farragoes and more are, for the project, examined in regard of their physical properties to find the best substitute fluid. The samples are examined at the rotational viscometer for viscosity at various shear rates and then compared with the viscosity values of liquid manure.

  8. An accurate estimation method of kinematic viscosity for standard viscosity liquids

    NASA Astrophysics Data System (ADS)

    Kurano, Y.; Kobayashi, H.; Yoshida, K.; Imai, H.

    1992-07-01

    Deming's method of least squares is introduced to make an accurate kinematic viscosity estimation for a series of 13 standard-viscosity liquids at any desired temperature. The empirical ASTM kinematic viscosity-temperature equation is represented in the form loglog( v+c)=a-b log T, where v (in mm2. s-1) is the kinematic viscosity at temperature T (in K), a and b are the constants for a given liquid, and c has a variable value. In the present application, however, c is assumed to have a constant value for each standard-viscosity liquid, as do a and b in the ASTM equation. This assumption has since been verified experimentally for all standard-viscosity liquids. The kinematic viscosities for the 13 standard-viscosity liquids have been measured with a high accuracy in the temperature range of 20 40°C using a series of the NRLM capillary master viscometers with an automatic flow time detection system. The deviations between measured and estimated kinematic viscosities were less than ±0.04% for the 10 standard-viscosity liquids JS2.5 to JS2000 and ±0.11% for the 3 standard-viscosity liquids JS15H to JS200H, respectively. From the above investigation, it was revealed that the uncertainty in the present estimation method is less than one-third that in the usual ASTM method.

  9. A rapid method to estimate Westergren sedimentation rates.

    PubMed

    Alexy, Tamas; Pais, Eszter; Meiselman, Herbert J

    2009-09-01

    The erythrocyte sedimentation rate (ESR) is a nonspecific but simple and inexpensive test that was introduced into medical practice in 1897. Although it is commonly utilized in the diagnosis and follow-up of various clinical conditions, ESR has several limitations including the required 60 min settling time for the test. Herein we introduce a novel use for a commercially available computerized tube viscometer that allows the accurate prediction of human Westergren ESR rates in as little as 4 min. Owing to an initial pressure gradient, blood moves between two vertical tubes through a horizontal small-bore tube and the top of the red blood cell (RBC) column in each vertical tube is monitored continuously with an accuracy of 0.083 mm. Using data from the final minute of a blood viscosity measurement, a sedimentation index (SI) was calculated and correlated with results from the conventional Westergren ESR test. To date, samples from 119 human subjects have been studied and our results indicate a strong correlation between SI and ESR values (R(2)=0.92). In addition, we found a close association between SI and RBC aggregation indices as determined by an automated RBC aggregometer (R(2)=0.71). Determining SI on human blood is rapid, requires no special training and has minimal biohazard risk, thus allowing physicians to rapidly screen for individuals with elevated ESR and to monitor therapeutic responses.

  10. Development of viscosity sensor with long period fiber grating technology

    NASA Astrophysics Data System (ADS)

    Lin, Jyh-Dong; Wang, Jian-Neng; Chen, Shih-Huang; Wang, Juei-Mao

    2009-03-01

    In this paper, we describe the development of a viscosity sensing system using a simple and low-cost long-period fiber grating (LPFG) sensor. The LPFG sensor was extremely sensitive to the refractive index of the medium surrounding the cladding surface of the sensing grating, thus allowing it to be used as an ambient index sensor or chemical concentration indicator. Viscosity can be simply defined as resistance to flow of a liquid. We have measured asphalt binder, 100-190000 centistokes, in comparison with optical sensing results. The system sensing asphalt binders exhibited increase trend in the resonance wavelength shift when the refractive index of the medium changed. The prototype sensor consisted of a LPFG sensing component and a cone-shaped reservoir where gravitational force can cause asphalt binders flow through the capillary. Thus the measured time for a constant volume of asphalt binders can be converted into either absolute or kinematic viscosity. In addition, a rotational viscometer and a dynamic shear rheometer were also used to evaluate the viscosity of this liquid, the ratio between the applied shear stress and rate of shear, as well as the viscoelastic property including complex shear modulus and phase angle. The measured time could be converted into viscosity of asphalt binder based on calculation. This simple LPFG viscosity sensing system is hopefully expected to benefit the viscosity measurement for the field of civil, mechanical and aerospace engineering.

  11. THE EFFECTS OF GAMMA IRRADIATION ON THE RHEOLOGICAL PROPERTIES OF WHEAT GLUTEN (in Japanese)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doguchi, M.; Yokoyama, Y.; Odaka, I.

    Wheat gluten samples were x irradiated at doses from 4 x 10/sup 6/ to 10/ sup 7/ rep, and the flours, prepared by mixing the gluten samples with wheat starch, were subjected to rheological tests. The apparent viscosities obtained by the McMichael viscometer and the maximum viscosity of the alkaline viscogram tended to decrease with increasing dosage. Farinograms and mixograms, obtained by the constant water absorption method, showed that the dough development curves changed their shape after irradiation; for example, the maximum resistance to mixing and the time to reach this maximum decreased. When the dosage was increased to moremore » than 3 x 10/sup 6/ rep, the samples lost the unique elastic and cohesive properties of wheat gluten. Moreover, as the irradiation dose increased, the extensigrams showed a notable decrease in resistance and a slight decrease in extensibility; such changes were not observed after treatment with either sulfhydryl-blocking reagents or by disulfide bond-splitting reagents. Gluten was so denatured at 10/sup 7/ rep that a dough could not be prepared from the sample. These results show that the changes of the rheological properties of wheat gluten induced by x irradiation are due to a structural change of the protein molecule of gluten rather than the breaking of disulfide bonds or blocking of sulfhydryl groups. (BBB)« less

  12. Synthesis and characterization of carboxymethyl potato starch and its application in reactive dye printing.

    PubMed

    Zhang, Bing; Gong, Honghong; Lü, Shaoyu; Ni, Boli; Liu, Mingzhu; Gao, Chunmei; Huang, Yinjuan; Han, Fei

    2012-11-01

    Carboxymethyl potato starch (CMPS) was synthesized with a simple dry and multi-step method as a product of the reaction of native potato starch and monochloroacetic acid in the presence of sodium hydroxide. The influence of the molar ratio of sodium hydroxide to anhydroglucose unit, the volume of 95% (v/v) ethanol, the rotation rate of motor driven stirrer and the reaction time for degree of substitution (DS) were evaluated. The product was characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray diffractometry (XRD). FTIR spectrometry showed new bonds at 1618 and 1424 cm⁻¹ when native starch underwent carboxymethylation. SEM pictures showed that the smooth surface of native starch particles was mostly ruptured. XRD revealed that starch crystallinity was reduced after carboxymethylation. The viscosity of the mixture paste of carboxymethyl starch and sodium alginate (SA) was measured using a rotational viscometer. In addition, the applied effect of mixed paste in reactive dye printing was examined by assessing the fabric stiffness, color yield and sharp edge to the printed image in comparison with SA. And the results indicated that the mixed paste could partially replace SA as thickener in reactive dye printing. The study also showed that the method was low cost and eco-friendly and the product would have an extensive application in reactive dye printing. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Comparative study between microvascular tone regulation and rheological properties of blood in patients with type 2 diabetes mellitus.

    PubMed

    Antonova, N; Tsiberkin, K; Podtaev, S; Paskova, V; Velcheva, I; Chaushev, N

    2016-01-01

    The aim of the study is to investigate the changes of the skin blood flow responses to cold stress in patients with diabetes mellitus type 2 through wavelet analysis of the peripheral skin temperature oscillations and to estimate their relationship with the blood viscosity values. The amplitudes of the skin temperature pulsations (ASTP) were monitored by "Microtest" device ("FM-Diagnostics", Russia); the whole blood viscosity and the shear stresses were measured by Contraves LS30 viscometer (Switzerland) at a steady flow in 9 healthy subjects and in 30 patients with type 2 diabetes mellitus. Power law and Herschel-Bulkley (HB) equations were applied to describe the blood rheology. Both models include consistency (k) and flow index (m), and the HB also gives the yield stress (τ0). The Spearman rank correlations between these parameters and the ASTP in the frequency ranges, corresponding to the myogenic, neurogenic and endothelial mechanisms of the microcirculation tone regulation were calculated. The ASTP values decreased when the blood viscosity increased. The correlation analysis revealed good ASTP-m (r > 0.5) and ASTP-k (r < -0.5) relationships in the endothelial range, while the ASTP-τ0 correlation was weaker (r≈-0.4). These correlations became lower for the ASTP during the cold stress. The results prompt manifestation of endothelial dysfunction in patients with type 2 diabetes.

  14. Utilization of modified starch from avocado (Persea americana Mill.) seed in cream soup production

    NASA Astrophysics Data System (ADS)

    Cornelia, M.; Christianti, A.

    2018-01-01

    Avocado (Persea americana Mill.) seed was often seen as waste and underutilized resources, especially in the food industry. The aim of this research was to modify the structure of avocado seed starch using the cross-linking method, to improve the viscosity stability in the cream soup. In the preliminary research, starch was isolated from the seed and modified by STPP (sodium tripolyphosphate) with 2%, 4%, and 6% concentration and were reacted for 1, 2, and 3 hours. Starches were analyzed for moisture and ash content, paste clarity, gel strength, swelling power, solubility, yield, and degree of whiteness. Based on the analysis results, the best reaction time and STPP concentration was 6% at 1 hour reaction time. Native starch and the best-modified starch were applied in the cream soup and compared with commercial cream soup. Cream soups were analyzed for viscosity stability using viscometer in 0, 1, 3, and 5 hours after storage in room temperature. The result showed that cream soup using modified starch has better viscosity stability than native starch and commercial cream soup after 5 hours storage, which was 181.7 ± 4.85 cP. Sensory analysis showed that cream soup using modified starch was more acceptable than the others. Avocado seed modified starch has phosphate group that strengthen the starch chain to prevent viscosity breakdown.

  15. Impact of plasma viscosity on microcirculatory flow after traumatic haemorrhagic shock: A prospective observational study.

    PubMed

    Naumann, David N; Hazeldine, Jon; Bishop, Jon; Midwinter, Mark J; Harrison, Paul; Nash, Gerard; Hutchings, Sam D

    2018-05-19

    Preclinical studies report that higher plasma viscosity improves microcirculatory flow after haemorrhagic shock and resuscitation, but no clinical study has tested this hypothesis. We investigated the relationship between plasma viscosity and sublingual microcirculatory flow in patients during resuscitation for traumatic haemorrhagic shock (THS). Sublingual video-microscopy was performed for 20 trauma patients with THS as soon as feasible in hospital, and then at 24 h and 48 h. Values were obtained for total vessel density, perfused vessel density, proportion of perfused vessels, microcirculatory flow index (MFI), microcirculatory heterogeneity index (MHI), and Point of Care Microcirculation (POEM) scores. Plasma viscosity was measured using a Wells-Brookfield cone and plate micro-viscometer. Logistic regression analyses examined relationships between microcirculatory parameters and plasma viscosity, adjusting for covariates (systolic blood pressure, heart rate, haematocrit, rate and volume of fluids, and rate of noradrenaline). Higher plasma viscosity was not associated with improved microcirculatory parameters. Instead, there were weakly significant associations between higher plasma viscosity and lower (poorer) MFI (p = 0.040), higher (worse) MHI (p = 0.033), and lower (worse) POEM scores (p = 0.039). The current study did not confirm the hypothesis that higher plasma viscosity improves microcirculatory flow dynamics in patients with THS. Further clinical investigations are warranted to determine whether viscosity is a physical parameter of importance during resuscitation of these patients.

  16. Effects of hydroxyurea on blood rheology in sickle cell anemia: A two-years follow-up study.

    PubMed

    Lemonne, Nathalie; Möckesch, Berenike; Charlot, Keyne; Garnier, Yohann; Waltz, Xavier; Lamarre, Yann; Antoine-Jonville, Sophie; Etienne-Julan, Maryse; Hardy-Dessources, Marie-Dominique; Romana, Marc; Connes, Philippe

    2017-01-01

    The aim of the present study was to test the effects of hydroxyurea (HU) therapy on clinical, hematological and hemorheological parameters in adult patients with sickle cell anemia (SCA). Hematological and hemorheological parameters were measured in 28 SCA patients before HU therapy (i.e., baseline) and at 6, 12 and 24 months of treatment. RBC deformability was determined by ektacytometry at 30 Pa. RBC aggregation properties were investigated by light-backscatter method. Blood viscosity was measured at 225 s-1 by a cone-plate viscometer. The rates of vaso-occlusive crises and acute chest syndrome were lower at 1 and 2 years of HU therapy compared to baseline. The proportion of patients with leg ulcers tended to decrease after 2 years of treatment. Hemoglobin oxygen saturation improved with HU therapy. HU therapy induced a decrease of platelet and white blood cell counts and a rise in fetal hemoglobin level and mean cell volume. While hemoglobin concentrations increased under HU, blood viscosity remained unchanged all along the study. RBC deformability increased over baseline values at 6 months of HU therapy and continued to rise until the end of the follow-up period. In conclusion, the improvement in RBC deformability probably compensates the increase of hemoglobin on blood viscosity and participates to the improvement of the clinical status of patients.

  17. Isolation, characterization and investigation of Plantago ovata husk polysaccharide as superdisintegrant.

    PubMed

    Pawar, Harshal; Varkhade, Chhaya

    2014-08-01

    Psyllium husk (Plantago ovata, Family: Plantaginaceae) contains a high proportion of hemicellulose, composed of a xylan backbone linked with arabinose, rhamnose, and galacturonic acid units (arabinoxylans). Polysaccharide was isolated from Psyllium husk using solvent precipitation method. The isolated polysaccharide was evaluated for various physicochemical parameters. The rheological behavior of polysaccharide (1% w/v in water) was studied using Brookfield viscometer. Polysaccharide derived from the husk of P. ovata was investigated as superdisintegrant in the fast dissolving tablets. Valsartan, an antihypertensive drug, was selected as a model drug. The tablets of Valsartan were prepared separately using different concentrations (1, 2.5, 5, 7.5% w/w) of isolated Plantago ovata (P. ovata) husk polysaccharide (Natural) and crospovidone as a synthetic superdisintegrant by direct compression method. The prepared tablets were evaluated for various pre-compression and post-compression parameters. The drug excipient interactions were characterized by FTIR studies. The formulation F4 containing7.5% polysaccharide showed rapid wetting time and disintegration time as compared to formulation prepared using synthetic superdisintegrant at the same concentration level. Hence batch F4 was considered as optimized formulation. The stability studies were performed on formulation F4. The disintegration time and in vitro drug release of the optimized formulation was compared with the marketed formulation (Conventional tablets). Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Enzymatic degradation of thiolated chitosan.

    PubMed

    Laffleur, Flavia; Hintzen, Fabian; Rahmat, Deni; Shahnaz, Gul; Millotti, Gioconda; Bernkop-Schnürch, Andreas

    2013-10-01

    The objective of this study was to evaluate the biodegradability of thiolated chitosans in comparison to unmodified chitosan. Mediated by carbodiimide, thioglycolic acid (TGA) and mercaptonicotinic acid (MNA) were covalently attached to chitosan via formation an amide bond. Applying two different concentrations of carbodiimide 50 and 100 mM, two chitosan TGA conjugates (TGA A and TGA B) were obtained. According to chitosan solution (3% m/v) thiomer solutions were prepared and chitosanolytic enzyme solutions were added. Lysozyme, pectinase and cellulase were examined in chitosan degrading activity. The enzymatic degradability of these thiomers was investigated by viscosity measurements with a plate-plate viscometer. The obtained chitosan TGA conjugate A displayed 267.7 µmol and conjugate B displayed 116.3 µmol of immobilized thiol groups. With 325.4 µmol immobilized thiol groups, chitosan MNA conjugate displayed the most content of thiol groups. In rheological studies subsequently the modification proved that chitosan TGA conjugates with a higher coupling rate of thiol groups were not only degraded to a lesser extent by 20.9-26.4% but also more slowly. Chitosan mercaptonicotinic acid was degraded by 31.4-50.1% depending the investigated enzyme and even faster than unmodified chitosan. According to these results the biodegradability can be influenced by various modifications of the polymer which showed in particular that the rate of biodegradation is increased when MNA is the ligand, whereas the degradation is hampered when TGA is used as ligand for chitosan.

  19. Determining the solution conformational entropy of oligosaccharides by SEC with on-line viscometry detection.

    PubMed

    Morris, Mallory J; Striegel, André M

    2014-06-15

    Introduced here is a method for determining the solution conformational entropy of oligosaccharides (-ΔS) that relies on the on-line coupling of size-exclusion chromatography (SEC), an entropically-controlled separation technique, and differential viscometry (VISC). Results from this SEC/VISC method were compared, for the same injections of the same sample dissolutions and under identical solvent/temperature conditions, to results from a benchmark SEC/differential refractometry (SEC/DRI) method which has been applied successfully over the last decade to determining -ΔS of a variety of mono-, di-, and oligosaccharides. The accuracy (as compared to SEC/DRI) and precision of SEC/VISC were found to be excellent, as was the sensitivity of the viscometer in the oligomeric region. The experiments presented here contrast three sets of (1→4)-β-d-oligosaccharides, namely manno-, cello-, and N-acetylchitooligosaccharides of degree of polymerization (DP) 2 through 6. For each series, the dependence of -ΔS on DP was found to be monotonic while, between series, differences at each DP could be ascribed to either the additional degrees of freedom imparted by large, multi-atomic substituent groups, or to the presence or absence of additional intramolecular hydrogen bonds, depending on the axial versus equatorial arrangement of particular hydroxyl groups. An hypothesis is advanced to explain the unexpectedly high sensitivity of viscometric detection for low-molar-mass analytes. The method presented can be extended to the analysis of oligosaccharides other than those studied here. Published by Elsevier Ltd.

  20. In vitro and in vivo evaluation of a novel testosterone transdermal delivery system (TTDS) using palm oil base

    PubMed Central

    Haron, Didi Erwandi Mohamad; Chik, Zamri; Noordin, Mohamed Ibrahm; Mohamed, Zahurin

    2015-01-01

    Objective (s): Transdermal preparations for testosterone are becoming popular because of their unique advantages such as avoidance of first-pass effect, convenience, improved bioavailability, and reduction of systemic side effects. A novel testosterone transdermal delivery system (TDDS) was developed using a palm oil base called HAMIN™ (a commercial product) and tested using in vitro and in vivo skin permeability test methods. Materials and Methods: The physical characteristics of the formulation such as particle size and viscosity were determined by using Franz diffusion cell and Brookfield viscometer, respectively. In vivo skin permeability test was performed on healthy rabbits through the skin. Testosterone in serum was analyzed using the validated Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) technique. Results: In vitro study showed that the cumulative amount of testosterone diffused was between 40 to 1400 ngcm-² over a period of five hr after application of TDDS through the artificial Strat-M™ membrane. In the in vivo rabbit skin permeability test, the results indicated that testosterone was well absorbed with a mean Cmax and Tmax of 60.94 ngml-1 and 2.29 hr after application of TDDS while no increase was observed in placebo treatment. Particle size analysis ranged from 79.4 nm to 630.0 nm for placebo and 97 to 774.0 nm for TDDS. Conclusion: The formulation was successfully prepared using HAMIN™, which has demonstrated great potential for topical delivery of testosterone. PMID:26877845

  1. Non-Newtonian behavior of plagioclase-bearing basaltic magma: Subliquidus viscosity measurement of the 1707 basalt of Fuji volcano, Japan

    NASA Astrophysics Data System (ADS)

    Ishibashi, Hidemi

    2009-03-01

    Laboratory measurements of viscosity were done for basalt erupted in 1707 AD from Fuji volcano, Japan, using a concentric cylinder rotational viscometer at temperatures of 1297-1157 °C, 1 atm pressure, and fO 2 near the Ni-NiO buffer. On cooling, elongated plagioclase crystals with a mean length/width ratio of ca. 8.5 appeared at 1237 °C, followed by olivine at 1157 °C. At progressively lower temperatures, the total crystal volume fraction increased monotonously to ca. 0.25; viscosity increased from 38.9 to 765 Pa s at a shear strain rate of 1 s - 1 . This basalt magma behaves as a Newtonian fluid at temperatures greater than 1217 °C, but shear-thinning behavior occurs at temperatures less than 1197 °C because of the suspended plagioclase crystals. This behavior is well approximated as a power law fluid. At the onset of shear thinning, the crystal volume fraction was between 0.06 and 0.13, which is attributed to the pronounced lath-shape of plagioclase crystals. The relative viscosity increases monotonously with increase of crystal volume fraction at a constant shear strain rate, and with decrease of shear strain rate at a constant crystal volume fraction. A modified form of the Krieger-Dougherty equation is introduced herein. It enables us to describe the dependencies of relative viscosity on both the crystal volume fraction and shear strain rate, and consequently the onset of shear-thinning behavior.

  2. Fluid shear stress sensitizes cancer cells to receptor-mediated apoptosis via trimeric death receptors

    NASA Astrophysics Data System (ADS)

    Mitchell, Michael J.; King, Michael R.

    2013-01-01

    Cancer metastasis, the process of cancer cell migration from a primary to distal location, typically leads to a poor patient prognosis. Hematogenous metastasis is initiated by intravasation of circulating tumor cells (CTCs) into the bloodstream, which are then believed to adhere to the luminal surface of the endothelium and extravasate into distal locations. Apoptotic agents such as tumor necrosis factor apoptosis-inducing ligand (TRAIL), whether in soluble ligand form or expressed on the surface of natural killer cells, have shown promise in treating CTCs to reduce the probability of metastasis. The role of hemodynamic shear forces in altering the cancer cell response to apoptotic agents has not been previously investigated. Here, we report that human colon cancer COLO 205 and prostate cancer PC-3 cells exposed to a uniform fluid shear stress in a cone-and-plate viscometer become sensitized to TRAIL-induced apoptosis. Shear-induced sensitization directly correlates with the application of fluid shear stress, and TRAIL-induced apoptosis increases in a fluid shear stress force- and time-dependent manner. In contrast, TRAIL-induced necrosis is not affected by the application fluid shear stress. Interestingly, fluid shear stress does not sensitize cancer cells to apoptosis when treated with doxorubicin, which also induces apoptosis in cancer cells. Caspase inhibition experiments reveal that shear stress-induced sensitization to TRAIL occurs via caspase-dependent apoptosis. These results suggest that physiological fluid shear forces can modulate receptor-mediated apoptosis of cancer cells in the presence of apoptotic agents.

  3. Experiment on ``discovery'' STS 51-C: Aggregation of red cells and thrombocytes in heart disease, hyperlipidaemia and other conditions

    NASA Astrophysics Data System (ADS)

    Dintenfass, L.

    The aim of this experiment was to study aggregation of red cells in the blood of patients with ischaemic heart disease, diabetes, hyperlipidaemia, and (silent) cancer, and in two normal donors. Reconstituted blood using IgG was also used. The instrument, the automated slit-capillary photo-viscometer (100 kg weight) was set on the middeck of the Space Shuttle. An analogous instrument was at the Kennedy Space Center. Blood was obtained from donors, anticoagulated, and adjusted to haematocrit of 30% using native plasma. Experiments took place at 25°C, during which blood was forced to flow in the slit formed by two parallel glass plates. Macro and microphotography was carried out at specific intervals controlled by a computer. During stasis, lasting 6 minutes, aggregates (or clumps) of the red cells were formed. Results indicated that red cell aggregates do form under zero-G; that such aggregates are smaller than the ones obtained at one-G; that morphology is different, the zero-G showing rouleaux while one-G showing usual sludge-like clumps of red cells in all severe disorders. Platelets appeared to remain monodisperse under zero-G. Assuming that these data can be confirmed, one could suggest that zero-G affects cell-cell interaction, and may consequently influence the internal microstructure of the cell membrane and of the receptors, as well as their activity. Gravitational studies may thus open a new door on immunology and haematology in general.

  4. Analysis of ingredient functionality and formulation optimization of an instant peanut beverage mix.

    PubMed

    Howard, Brandy M; Hung, Yen-Con; McWatters, S Kay

    2010-01-01

    Powder for an instant shake-style beverage was created using partially defatted peanut flour (12% fat), granulated sugar, and nonfat dry milk (NFDM). The 3 main components, along with constant amounts of stabilizing gums and anti-caking silica, were mixed together and finely milled in a Super Wing Mill to further reduce the particle sizes. Drinks from each formula variation were prepared and analyzed for viscosity (digital viscometer), color (colorimeter), and separation rate. Each beverage was also analyzed by consumers to determine acceptability of flavor, mouth-feel, and color. Physical test results show that viscosity increased with increasing proportion of peanut flour in the formula, and viscosity decreased with increasing levels of sugar and NFDM. For each formula, the samples at refrigerated temperature (4 degrees C) were less viscous than those at ambient temperatures (23 to 25 degrees C). Color values show that the beverage powder color was mostly influenced by peanut flour percentage, becoming darker with increasing levels of peanut flour. Prepared beverage color was influenced by both NFDM and peanut flour percentage; lightness increased with increasing NFDM percentage and decreased with increasing peanut flour percentage. Separation rates were most affected by the proportion of NFDM in the formula; higher levels decreased the rate of separation. Refrigeration slowed the rate of separation in all samples. Response surface analysis of consumer test data showed that the most acceptable formulation for the peanut beverage included approximately equal amounts of peanut flour, sugar, and NFDM.

  5. Quantitative Correlation between Viscosity of Concentrated MAb Solutions and Particle Size Parameters Obtained from Small-Angle X-ray Scattering.

    PubMed

    Fukuda, Masakazu; Moriyama, Chifumi; Yamazaki, Tadao; Imaeda, Yoshimi; Koga, Akiko

    2015-12-01

    To investigate the relationship between viscosity of concentrated MAb solutions and particle size parameters obtained from small-angle X-ray scattering (SAXS). The viscosity of three MAb solutions (MAb1, MAb2, and MAb3; 40-200 mg/mL) was measured by electromagnetically spinning viscometer. The protein interactions of MAb solutions (at 60 mg/mL) was evaluated by SAXS. The phase behavior of 60 mg/mL MAb solutions in a low-salt buffer was observed after 1 week storage at 25°C. The MAb1 solutions exhibited the highest viscosity among the three MAbs in the buffer containing 50 mM NaCl. Viscosity of MAb1 solutions decreased with increasing temperature, increasing salt concentration, and addition of amino acids. Viscosity of MAb1 solutions was lowest in the buffer containing histidine, arginine, and aspartic acid. Particle size parameters obtained from SAXS measurements correlated very well with the viscosity of MAb solutions at 200 mg/mL. MAb1 exhibited liquid-liquid phase separation at a low salt concentration. Simultaneous addition of basic and acidic amino acids effectively suppressed intermolecular attractive interactions and decreased viscosity of MAb1 solutions. SAXS can be performed using a small volume of samples; therefore, the particle size parameters obtained from SAXS at intermediate protein concentration could be used to screen for low viscosity antibodies in the early development stage.

  6. Type of adsorbent and column height in adsorption process of used cooking oil

    NASA Astrophysics Data System (ADS)

    Hasnelly, Hervelly, Taufik, Yusman; Melany, Ivo Nila

    2015-12-01

    The purpose of this research was to find out the best adsorbent and column height that can adsorb color and soluble impurities substances in used cooking oil. This research was meant for knowledge development of refined cooking oil technology. The used of this research was giving out information on the recycling process of used cooking oil. Research design used 2 × 2 factorial pattern in randomized group design with 6 repetitions. The first factor is adsorbent type (J) that consist of activated carbon (J1) and Zeolit (J2). The second factor is column height (K) with variations of 15 cm (k1) and 20 cm (k2). Chemical analysis parameter are free fatty acid, water content and saponification value. Physical parameter measurement was done on color with Hunter Lab system analysis and viscosity using viscometer method. Chemical analysis result of preliminary research on used cooking oil showed water content of 1,9%, free fatty acid 1,58%, saponification value 130,79 mg KOH/g oil, viscosity 0,6 d Pas and color with L value of -27,60, a value 1,04 and b value 1,54. Result on main research showed that adsorbent type only gave effect on water content whereas column height and its interaction was not gave significant effect on water content. Interaction between adsorbent type (J) and column height (K) gave significant effect to free fatty acid, saponification value, viscosity and color for L, a and b value of recycled cooking oil.

  7. Modeling the reversible kinetics of neutrophil aggregation under hydrodynamic shear.

    PubMed Central

    Neelamegham, S; Taylor, A D; Hellums, J D; Dembo, M; Smith, C W; Simon, S I

    1997-01-01

    Neutrophil emigration into inflamed tissue is mediated by beta 2-integrin and L-selectin adhesion receptors. Homotypic neutrophil aggregation is also dependent on these molecules, and it provides a model system in which to study adhesion dynamics. In the current study we formulated a mathematical model for cellular aggregation in a linear shear field based on Smoluchowski's two-body collision theory. Neutrophil suspensions activated with chemotactic stimulus and sheared in a cone-plate viscometer rapidly aggregate. Over a range of shear rates (400-800 s-1), approximately 90% of the single cells were recruited into aggregates ranging from doublets to groupings larger than sextuplets. The adhesion efficiency fit to these kinetics reached maximum levels of > 70%. Formed aggregates remained intact and resistant to shear up to 120 s, at which time they spontaneously dissociated back to singlets. The rate of cell disaggregation was linearly proportional to the applied shear rate, and it was approximately 60% lower for doublets as compared to larger aggregates. By accounting for the time-dependent changes in adhesion efficiency, disaggregation rate, and the effects of aggregate geometry, we succeeded in predicting the reversible kinetics of aggregation over a wide range of shear rates and cell concentrations. The combination of viscometry with flow cytometry and mathematical analysis as presented here represents a novel approach to differentiating between the effects of hydrodynamics and the intrinsic biological processes that control cell adhesion. Images FIGURE 3 FIGURE 5 PMID:9083659

  8. The development of a nutritious low cost weaning food for Kenya infants.

    PubMed

    Ward, D; Ainsworth, P

    1998-01-01

    The aim of this research was to develop an inexpensive weaning food of adequate dietary energy, protein and fat, for an infant of four to six months, that can be manufactured in Kenya, using readily available resources and technology. Product formulation was developed by using low cost, readily available and culturally acceptable food products. A cooked porridge was prepared using the traditional oven top method. Subsequently, the porridge was drum dried, blended with ground pumpkin seeds, heat sealed and stored at ambient temperature (22 degrees Centigrade) for eight weeks. Chemical analysis was then carried out to determine the total percentage energy, protein, fat and carbohydrate content of the dried mix. All were in accordance with the theoretical values. This analysis indicated that in order to meet the recommended daily allowances for fat and energy, the addition of oil was necessary, this value was calculated theoretically. In vitro protein digestibility was 82.5 per cent, confirming a high quality protein food. HPLC analysis detected no free floating water soluble amino acids, indicating food stability. A low peroxide value was found, confirming a rancid free food. Viscometer analysis of the reconstituted mix confirmed a nutrient and energy dense food at an acceptable consistency for infant feeding. The addition of a small amount of oil, to the reconstituted mix lowered the viscosity, allowing for the addition of an increase in the quality of dried mix, increasing both nutrient and energy density. The organoleptic qualities of the food were evaluated by a semi-trained panel. The overall appearance was highly rated, with flavour slightly less favourable.

  9. Biomechanics of P-selectin PSGL-1 bonds: Shear threshold and integrin-independent cell adhesion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Zhihua; Goldsmith, Harry L.; MacIntosh, Fiona A.

    2006-03-01

    Platelet-leukocyte adhesion may contribute to thrombosis and inflammation. We examined the heterotypic interaction between unactivated neutrophils and either thrombin receptor activating peptide (TRAP) stimulated platelets or P-selectin bearing beads (Ps-beads) in suspension. Cone-plate viscometers were used to apply controlled shear rates from 14-3000/s. Platelet-neutrophil and bead-neutrophil adhesion analysis was performed using both flow cytometry and high-speed videomicroscopy. We observed that while blocking antibodies against either P-selectin or P-selectin glycoprotein ligand-1 (PSGL-1) alone inhibited platelet-neutrophil adhesion by ~60% at 140/s, these reagents completely blocked adhesion at 3000/s. Anti-Mac-1 alone did not alter platelet-neutrophil adhesion rates at any shear rate, though inmore » synergy with selectin antagonists it abrogated cell binding. Unstimulated neutrophils avidly bound Ps-beads and activated platelets in an integrin-independent manner, suggesting that purely selectin-dependent cell adhesion is possible. In support of this, antagonists against P-selectin or PSGL-1 dissociated previously formed platelet-neutrophil and Ps-bead neutrophil aggregates under shear in a variety of experimental systems, including in assays performed with whole blood. In studies where medium viscosity and shear rate were varied, a subtle shear threshold for P-selectin PSGL-1 binding was also noted at shear rates<100/s and at force loading rates of ~300pN/sec. Results are discussed in light of biophysical computations that characterize the collision between unequal size particles in linear shear flow. Overall, our studies reveal an integrin-independent regime for cell adhesion that may be physiologically relevant.« less

  10. Project support of practical training in biophysics.

    PubMed

    Mornstein, V; Vlk, D; Forytkova, L

    2006-01-01

    The Department of Biophysics ensures practical training in biophysics and related subjects for students of medical and health study programmes. Demonstrations of medical technology are an important part of this training. Teaching for Faculty of Sciences in biophysical study programmes becomes also very important. Some lectures and demonstrations of technology are involved, but the practical trainig is missing. About 1 mil. CZK for additional laboratory equipment was obtained from the HEIDF project No. 1866/ 2005 "The demonstration and measuring technology for education in medical biophysics and radiological physics" for measuring system DEWETRON for high frequency signal analysis, Fluke Ti30 IR camera, PM 9000B patient monitor, ARSENAL AF 1 fluorescence microscope, and Nikon Coolpix 4500 digital camera with accessories for microphotography. At the present time, further financial resources are being provided by a development project of Ministry of Education "Inter-university co-operation in biomedical technology and engineering using top technologies" in total amount of almost 5 mil CZK, whereas over 2 mil CZK from this project are reserved for student laboratory equipment. The main goal of this project is to ensure the participation of Medical Faculty in educational co-operation in the biomedical technology and engineering, namely with the Faculty of Electrical Engineering and Communication (FEEC), Brno University of Technology. There will be taught those areas of biophysics which are not covered by FEEC, thus forming a separate subject "General Biophysics". The following instruments will be installed: UV-VIS spectrophotometers, rotation viscometers, tensiometers, microscopes with digital image processing, cooled centrifuge, optical benches, and some smaller instruments for practical measurements.

  11. Aggregation and disaggregation kinetics of human blood platelets: Part II. Shear-induced platelet aggregation.

    PubMed Central

    Huang, P Y; Hellums, J D

    1993-01-01

    A population balance equation (PBE) mathematical model for analyzing platelet aggregation kinetics was developed in Part I (Huang, P. Y., and J. D. Hellums. 1993. Biophys. J. 65: 334-343) of a set of three papers. In this paper, Part II, platelet aggregation and related reactions are studied in the uniform, known shear stress field of a rotational viscometer, and interpreted by means of the model. Experimental determinations are made of the platelet-aggregate particle size distributions as they evolve in time under the aggregating influence of shear stress. The PBE model is shown to give good agreement with experimental determinations when either a reversible (aggregation and disaggregation) or an irreversible (no disaggregation) form of the model is used. This finding suggests that for the experimental conditions studied disaggregation processes are of only secondary importance. During shear-induced platelet aggregation, only a small fraction of platelet collisions result in the binding together of the involved platelets. The modified collision efficiency is approximately zero for shear rates below 3000 s-1. It increases with shear rates above 3000 s-1 to about 0.01 for a shear rate of 8000 s-1. Addition of platelet chemical agonists yields order of magnitude increases in collision efficiency. The collision efficiency for shear-induced platelet aggregation is about an order of magnitude less at 37 degrees C than at 24 degrees C. The PBE model gives a much more accurate representation of aggregation kinetics than an earlier model based on a monodispersed particle size distribution. PMID:8369442

  12. Pluronic lecithin organogel as a topical drug delivery system.

    PubMed

    Pandey, Mohit; Belgamwar, Veena; Gattani, Surendra; Surana, Sanjay; Tekade, Avinash

    2010-01-01

    The objective of this study was to formulate and evaluate the pluronic lecithin organogel containing flurbiprofen for topical application. Different formulations of pluronic lecithin organogels were prepared by using pluronic F127, lecithin, flurbiprofen, isopropyl palmitate, water, sorbic acid, and potassium sorbate. To study the in vitro potential of these formulations, permeation studies were performed with Keshary-Chien diffusion cells. The results of the in vitro permeation studies found that release of flurbiprofen from dialysis membrane-70 was more than excised dorsal rat skin. Gelation temperature study was carried out to determine the temperature where sol-gel transformation takes place. The viscosities of different formulations were determined by using Brookfield Viscometer at 25°C, the viscosity of formulations increases as the lecithin concentration increases. Also the formulations were tested for appearance and feel psychorheologically, pH, and drug content. Interactions between the components of the gel have been investigated by differential scanning calorimetry and X-ray powder diffractometry. The optimized formulation subjected to differential scanning calorimetry shows no drug-polymer interaction. To investigate the in vivo performance of the formulations, a carrageenan-induced rat paw edema model and skin irritation study was used. The stability studies and freeze-thaw thermal cyclic test were carried out, showing no phase separation of gel, and representing gel stability. Statistical analysis of the data of animal study (anti-inflammatory activity) was done by using one way analysis of variance (ANOVA) followed by Dunnett's test. The formulation shows a statistically significant anti-inflammatory activity and is non-irritant to skin.

  13. Increased plasma viscosity in young women with polycystic ovary syndrome using an oral contraceptive containing 35 μg ethinyl estradiol and 2 mg cyproterone acetate.

    PubMed

    Markantes, George; Saltamavros, Alexandros D; Vervita, Vasiliki; Armeni, Anastasia K; Karela, Anastasia; Adonakis, George; Decavalas, George; Georgopoulos, Neoklis A

    2011-12-01

    To investigate the influence of 6 months of treatment with an oral contraceptive (OC) containing 35 μ g ethinyl estradiol and 2 mg cyproterone acetate on plasma viscosity (PV) in young women with polycystic ovary syndrome (PCOS). Patients with PCOS were assessed for PV before and after 6 months of treatment with an OC containing 35 μg ethinyl estradiol and 2 mg cyproterone acetate. PV was determined by a viscometer Type 53610/I SCHOTT-Instruments, Mainz at 37°C. Subjects were recruited from the Department of Obstetrics and Gynaecology, Division of Reproductive Endocrinology at the University Hospital of Patras, Greece. The study included 66 young women with PCOS. PV. In PCOS women as a whole, PV at baseline was 1.249 ± 0.049 mm(2)/s (n = 66). After 6 months of treatment with an OC containing 35 μg ethinyl estradiol and 2 mg cyproterone acetate, PV was increased to 1.268 ± 0.065 mm(2)/s (p = 0.038). The difference between PV before and after 6 months of treatment with an OC containing 35 μg ethinyl estradiol and 2 mg cyproterone acetate (Δviscosity) was 0.01864 ± 0.071452 mm(2)/s. ΔViscosity was related to ?fibrinogen (r = 0.270, p = 0.046), to Δhematocrit (r = 0.514, p = 0.09) and to Δtriglycerides (r = 0.292, p = 0.021). Young women with PCOS presented an increased PV under OC treatment with 35 μg ethinyl estradiol and 2 mg cyproterone acetate.

  14. von Willebrand factor (VWF) propeptide binding to VWF D'D3 domain attenuates platelet activation and adhesion.

    PubMed

    Madabhushi, Sri R; Shang, Chengwei; Dayananda, Kannayakanahalli M; Rittenhouse-Olson, Kate; Murphy, Mary; Ryan, Thomas E; Montgomery, Robert R; Neelamegham, Sriram

    2012-05-17

    Noncovalent association between the von Willebrand factor (VWF) propeptide (VWFpp) and mature VWF aids N-terminal multimerization and protein compartmentalization in storage granules. This association is currently thought to dissipate after secretion into blood. In the present study, we examined this proposition by quantifying the affinity and kinetics of VWFpp binding to mature VWF using surface plasmon resonance and by developing novel anti-VWF D'D3 mAbs. Our results show that the only binding site for VWFpp in mature VWF is in its D'D3 domain. At pH 6.2 and 10mM Ca(2+), conditions mimicking intracellular compartments, VWFpp-VWF binding occurs with high affinity (K(D) = 0.2nM, k(off) = 8 × 10(-5) s(-1)). Significant, albeit weaker, binding (K(D) = 25nM, k(off) = 4 × 10(-3) s(-1)) occurs under physiologic conditions of pH 7.4 and 2.5mM Ca(2+). This interaction was also observed in human plasma (K(D) = 50nM). The addition of recombinant VWFpp in both flow-chamber-based platelet adhesion assays and viscometer-based shear-induced platelet aggregation and activation studies reduced platelet adhesion and activation partially. Anti-D'D3 mAb DD3.1, which blocks VWFpp binding to VWF-D'D3, also abrogated platelet adhesion, as shown by shear-induced platelet aggregation and activation studies. Our data demonstrate that VWFpp binding to mature VWF occurs in the circulation, which can regulate the hemostatic potential of VWF by reducing VWF binding to platelet GpIbα.

  15. Rheological behavior on treated Malaysian crude oil

    NASA Astrophysics Data System (ADS)

    Chandran, Krittika; Sinnathambi, Chandra Mohan

    2016-11-01

    Crude oil is always produced with water. This association causes many problems during oil production, arising from the formation of emulsion. Emulsion is an undesirable substance that increases operational and capital cost in the pipeline and processing equipment. To overcome this issue, demulsifiers are formulated to break the emulsion, where they are able to separate the water-oil emulsions to their respective phases. The emulsifier's main function is to reduce the interfacial tension properties of the emulsion. For this research, both the EOR and natural water-in-oil emulsions were treated with low a concentration demulsifier. The main objective of this paper is to determine the dynamic viscosity and rheological properties of the treated EOR and natural emulsion. The dynamic viscosity was obtained using the Brook-field Digital Viscometer. The components that influence the emulsion's rheological properties are the temperature, shear rate and shear stress. The results obtained demonstrate that the viscosity of the treated crude decreases and portrays the Non-Newtonian shear thinning "pseudo-plastic" behavior. Besides that, to determine the interfacial film of the treated crude, the spinning drop tensiometer was used. With the addition of demulsifier, the thinning rate of the oil film accelerates whereby there is a linear decrease in the interfacial tension with an increase in time. Therefore, from the results, it can be observed that the rheology study plays a significant role in the demulsification test. Furthermore, both the rheology approaches showed that time, temperature, shear rate and shear stress have a great impact on the viscosity behavior as well as the IFT.

  16. Surfactant-Influenced Gas-Liquid Interfaces: Nonlinear Equation of State and Finite Surface Viscosities.

    PubMed

    Lopez; Hirsa

    2000-09-15

    A canonical flow geometry was utilized for a fundamental study of the coupling between bulk flow and a Newtonian gas-liquid interface in the presence of an insoluble surfactant. We develop a Navier-Stokes numerical model of the flow in the deep-channel surface viscometer geometry, which consists of stationary inner and outer cylinders, a floor rotating at a constant angular velocity, and an interface covered initially by a uniformly distributed surfactant. Here, the floor of the annular channel is rotated fast enough so the flow is nonlinear and drives the film toward the inner cylinder. The boundary conditions at the interface are functions of the surface tension, surface shear viscosity, and surface dilatational viscosity, as described by the Boussinesq-Scriven surface model. A physical surfactant system, namely hemicyanine, an insoluble monolayer on an air-water interface, with measured values of surface tension and surface shear viscosity versus concentration, was used in this study. We find that a surfactant front can form, depending on the Reynolds number and the initial surfactant concentration. The stress balance in the radial direction was found to be dominated by the Marangoni stress, but the azimuthal stress was only due to the surface shear viscosity. Numerical studies are presented comparing results of surfactant-influenced interface cases implementing the derived viscoelastic interfacial stress balance with those using a number of idealized stress balances, as well as a rigid no-slip surface, providing added insight into the altered dynamics that result from the presence of a surfactant monolayer. Copyright 2000 Academic Press.

  17. Synthesis of oxidized guar gum by dry method and its application in reactive dye printing.

    PubMed

    Gong, Honghong; Liu, Mingzhu; Zhang, Bing; Cui, Dapeng; Gao, Chunmei; Ni, Boli; Chen, Jiucun

    2011-12-01

    The aim of this study was to prepare oxidized guar gum with a simple dry method, basing on guar gum, hydrogen peroxide and a small amount of solvent. To obtain a product with suitable viscosity for reactive dye printing, the effects of various factors such as the amount of oxidant and solvent, reaction temperature and time were studied with respect to the viscosity of reaction products. The product was characterized by Fourier transform infrared spectroscopy, size exclusion chromatography, scanning electron microscopy and differential scanning calorimetry. The hydrated rate of guar gum and oxidized guar gum was estimated through measuring the required time when their solutions (1%, w/v) reached the maximum viscosity. The effects of the salt concentration and pH on viscosity of the resultant product were studied. The mixed paste containing oxidized guar gum and carboxymethyl starch was prepared and its viscosity was determined by the viscometer. The rheological property of the mixed paste was appraised by the printing viscosity index. In addition, the applied effect of mixed paste in reactive dye printing was examined by assessing the fabric stiffness, color yield and sharp edge to the printed image in comparison with sodium alginate. And the results indicated that the mixed paste could partially replace sodium alginate as thickener in reactive dye printing. The study also showed that the method was low cost and eco-friendly and the product would have an extensive application in reactive dye printing. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Measurement of the dynamic viscosity of hybrid engine oil -Cuo-MWCNT nanofluid, development of a practical viscosity correlation and utilizing the artificial neural network

    NASA Astrophysics Data System (ADS)

    Aghaei, Alireza; Khorasanizadeh, Hossein; Sheikhzadeh, Ghanbar Ali

    2018-01-01

    The main objectives of this study have been measurement of the dynamic viscosity of CuO-MWCNTs/SAE 5w-50 hybrid nanofluid, utilization of artificial neural networks (ANN) and development of a new viscosity model. The new nanofluid has been prepared by a two-stage procedure with volume fractions of 0.05, 0.1, 0.25, 0.5, 0.75 and 1%. Then, utilizing a Brookfield viscometer, its dynamic viscosity has been measured for temperatures of 5, 15, 25, 35, 45, 55 °C. The experimental results demonstrate that the viscosity increases by increasing the nanoparticles volume fraction and decreases by increasing temperature. Based on the experimental data the maximum and minimum nanofluid viscosity enhancements, when the volume fraction increases from 0.05 to 1, are 35.52% and 12.92% for constant temperatures of 55 and 15 °C, respectively. The higher viscosity of oil engine in higher temperatures is an advantage, thus this result is important. The measured nanofluid viscosity magnitudes in various shear rates show that this hybrid nanofluid is Newtonian. An ANN model has been employed to predict the viscosity of the CuO-MWCNTs/SAE 5w-50 hybrid nanofluid and the results showed that the ANN can estimate the viscosity efficiently and accurately. Eventually, for viscosity estimation a new temperature and volume fraction based third-degree polynomial empirical model has been developed. The comparison shows that this model is in good agreement with the experimental data.

  19. Squeezing flow viscometry for nonelastic semiliquid foods--theory and applications.

    PubMed

    Campanella, Osvaldo H; Peleg, Micha

    2002-01-01

    In most conventional rheometers, notably the coaxial cylinders and capillary viscometers, the food specimen is pressed into a narrow gap and its structure is altered by uncontrolled shear. Also, most semiliquid foods exhibit slip, and consequently the measurements do not always reflect their true rheological properties. A feasible solution to these two problems is squeezing flow viscometry where the specimen, practically intact and with or without suspended particles, is squeezed between parallel plates. The outward flow pattern mainly depends on the friction between the fluid and plates or its absence ("lubricated squeezing flow"). Among the possible test geometries, the one of constant area and changing volume is the most practical for foods. The test can be performed at a constant displacement rate using common Universal Testing Machines or under constant loads (creep array). The tests output is in the form of a force-height, force-time, or height-time relationship, from which several rheological parameters can be derived. With the current state of the art, the method can only be applied at small displacement rates. Despite the method's crudeness, its results are remarkably reproducible and sensitive to textural differences among semiliquid food products. The flow patterns observed in foods do not always follow the predictions of rheological models originally developed for polymer melts because of the foods' unique microstructures. The implications of these discrepancies and the role that artifacts may play are evaluated in light of theoretical and practical considerations. The use of squeezing flow viscometry to quantify rheological changes that occur during a product's handling and to determine whether they are perceived sensorily is suggested.

  20. [Viscosity determination of synovial fluids from the canine hip and elbow joint as well as the human knee joint].

    PubMed

    Helms, Gabriele; Rittmann, Pia; Wefstaedt, Patrick; Windhagen, Henning; Pressel, Thomas; Behrens, Bernd-Arno; Nolte, Ingo

    2008-01-01

    The development of pathological changes in both human and canine hip joints is mainly caused by a lack of synovial fluid lubrication. This results in an increased joint abrasion. Even after implantation of joint prosthesis, inadequate lubrication can lead to abrasion in the tribological pair. This can finally result in aseptic loosening of the prosthesis. In spite of the enormous number of studies that have been performed on human, only little knowledge about the tribological properties of the joints in dogs is available in the literature. For this reason the viscosities of synovial fluid, derived from physiological and pathologically changed canine elbow joints were measured. The viscosities were determined by the use of a cone-plate viscometer at different temperatures and shear rates. The obtained values were compared with the viscosity values of pathologically changed synovial fluids from human knee joints as well as with pathological samples from the canine hip joint. The results show that the viscosity values vary within a series of measurements and are inversely proportional to the temperature of the sample and the shear rate. The differences between the average viscosities of canine and human synovial fluids taken from pathologically changed joints are below 4% (22.5 s(-1) at theta1 = 25 degrees C). The findings of this study are being implemented in a FE-Model for the computation of actual forces in the hip joint during different movements. This would represent a contribution to an improved prosthetic treatment of canine and human hips.

  1. Factors affecting the viscosity of sodium hypochlorite and their effect on irrigant flow.

    PubMed

    Bukiet, F; Soler, T; Guivarch, M; Camps, J; Tassery, H; Cuisinier, F; Candoni, N

    2013-10-01

    To assess the influence of concentration, temperature and surfactant addition to a sodium hypochlorite solution on its dynamic viscosity and to calculate the corresponding Reynolds number to determine the corresponding flow regimen. The dynamic viscosity of the irrigant was assessed using a rotational viscometer. Sodium hypochlorite with concentrations ranging from 0.6% to 9.6% was tested at 37 and 22 °C. A wide range of concentrations of three different surfactants was mixed in 2.4% sodium hypochlorite for viscosity measurements. The Reynolds number was calculated under each condition. Data were analysed using two-way anova. There was a significant influence of sodium hypochlorite concentration (P < 0.001) and temperature (P < 0.001) on dynamic viscosity: the latter significantly increased with sodium hypochlorite concentration and decreased with temperature. A significant influence of surfactant concentration on dynamic viscosity (P < 0.001) occurred, especially for high surfactant concentrations: 6.25% for benzalkonium chloride, 15% for Tween 80 and 6.25% for Triton X-100. Reynolds number values calculated for a given flow rate (0.14 mL s(-1)), and root canal diameter (sizes 45 and 70) clearly qualified the irrigant flow regimen as laminar. Dynamic viscosity increased with sodium hypochlorite and surfactant concentration but decreased with temperature. Under clinical conditions, all viscosities measured led to laminar flow. The transition between laminar and turbulent flow may be reached by modifying different parameters at the same time: increasing flow rate and temperature whilst decreasing irrigant viscosity by adding surfactants with a high value of critical micellar concentration. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Challenges in Determining Intrinsic Viscosity Under Low Ionic Strength Solution Conditions.

    PubMed

    Pindrus, Mariya A; Shire, Steven J; Yadav, Sandeep; Kalonia, Devendra S

    2017-04-01

    To determine the intrinsic viscosity of several monoclonal antibodies (mAbs) under varying pH and ionic strength solution conditions. An online viscosity detector attached to HPLC (Viscotek®) was used to determine the intrinsic viscosity of mAbs. The Ross and Minton equation was used for viscosity prediction at high protein concentrations. Bulk viscosity was determined by a Cambridge viscometer. At 15 mM ionic strength, intrinsic viscosity of the mAbs determined by the single-point approach varied from 5.6 to 6.4 mL/g with changes in pH. High ionic strength did not significantly alter intrinsic viscosity, while a significant increase (up to 24.0 mL/g) was observed near zero mM. No difference in bulk viscosity of mAb3 was observed around pH 6 as a function of ionic strength. Data analysis revealed that near zero mM ionic strength limitations of the single-point technique result in erroneously high intrinsic viscosity. Intrinsic viscosity is a valuable tool that can be used to model baseline viscosity at higher protein concentrations. However, it is not predictive of solution non-ideality at higher protein concentrations. Furthermore, breakdown of numerous assumptions limits the applicability of experimental techniques near zero mM ionic strength conditions. For molecules and conditions studied, the single-point approach produced reliable intrinsic viscosity results at 15 mM. However, this approach must be used with caution near zero mM ionic strength. Data analysis can be used to reveal whether determined intrinsic viscosity is reliable or erroneously high.

  3. Pressure dependence of viscosity in supercooled water and a unified approach for thermodynamic and dynamic anomalies of water

    PubMed Central

    Singh, Lokendra P.; Issenmann, Bruno; Caupin, Frédéric

    2017-01-01

    The anomalous decrease of the viscosity of water with applied pressure has been known for over a century. It occurs concurrently with major structural changes: The second coordination shell around a molecule collapses onto the first shell. Viscosity is thus a macroscopic witness of the progressive breaking of the tetrahedral hydrogen bond network that makes water so peculiar. At low temperature, water at ambient pressure becomes more tetrahedral and the effect of pressure becomes stronger. However, surprisingly, no data are available for the viscosity of supercooled water under pressure, in which dramatic anomalies are expected based on interpolation between ambient pressure data for supercooled water and high pressure data for stable water. Here we report measurements with a time-of-flight viscometer down to 244K and up to 300MPa, revealing a reduction of viscosity by pressure by as much as 42%. Inspired by a previous attempt [Tanaka H (2000) J Chem Phys 112:799–809], we show that a remarkably simple extension of a two-state model [Holten V, Sengers JV, Anisimov MA (2014) J Phys Chem Ref Data 43:043101], initially developed to reproduce thermodynamic properties, is able to accurately describe dynamic properties (viscosity, self-diffusion coefficient, and rotational correlation time) as well. Our results support the idea that water is a mixture of a high density, “fragile” liquid, and a low density, “strong” liquid, the varying proportion of which explains the anomalies and fragile-to-strong crossover in water. PMID:28404733

  4. Pseudoplasticity of Propellant Slurry with Varied Aluminium Content for Castability Development

    NASA Astrophysics Data System (ADS)

    Restasari, A.; Budi, R. S.; Hartaya, K.

    2018-04-01

    The modification of the percentage of aluminium is necessary to obtain certain specific impulse. But, it affects the pseudoplasticity of propellant in elapsed time that is important in casting. Therefore, this research attempts to investigate the pseudoplasticity of propellant slurry with varied aluminium contents and as time elapsed, the range of percentage of aluminium and time that allows propellant slurry to be well processed. The methods include measuring the viscosity of propellant slurries that contain 6, 8, 10, 12, 14, 16 and 18% of aluminium at varied shear rates until 40 minutes after mixing by using Brookfield viscometer. The graphs of viscosity versus shear rate were made to determine pseudoplasticity index. After that, the graph volume fraction versus pseudoplasticity index were made to be investigated. It is concluded that the more aluminium contents, the slurries with 6 to 12% aluminium contents exhibit more pseudoplastic behaviour, but the slurries with 12 to 16% aluminium exhibit less pseudoplastic. While, slurry of 18% aluminium exhibit high pseudoplasticity. In the correlation with the time, the slurry compositions of 6, 8, 14, 16% aluminium become more pseudoplastic as time elapsed. While, for compositions of 10, 12 and 18% aluminium, the trend becomes contrary. Based on the pseudoplasticity index, propellant slurries that contain 10 and 14% of aluminium are suitable for pressure casting. While for slurries with 6, 8 and 16% of aluminium are also suitable for vacuum casting. All of those suitability are possesed until 40 minutes after mixing. While, the composition of slurries that contain 12 and 18% of aluminium need to be modified to enhanced its castability.

  5. Analysis of the Relationships between Waste Cooking Oil Qualities and Rejuvenated Asphalt Properties

    PubMed Central

    Zhang, Dong; Chen, Meizhu; Wu, Shaopeng; Liu, Jingxiang; Amirkhanian, Serji

    2017-01-01

    Waste cooking oil (WCO), in many cases, can rejuvenate aged asphalt and restore its properties. However, the influence of WCO qualities on rejuvenation behaviors of aged asphalt has not been investigated in detail. The objective of this paper was to evaluate the effects of WCO viscosity and acid value on the basic, rheological, and chemical properties of a typical rejuvenated asphalt. Penetration, ring and ball (R and B) softening point, and ductility were tested to evaluate the influence of WCO qualities on basic properties of rejuvenated asphalts. Then, the rheological properties of rejuvenated asphalt were characterized based on rotational viscometer (RV), dynamic shear rheometer (DSR), and bending beam rheometer (BBR) test results. Further, SARA (saturates, aromatics, resins, and asphaltenes) fraction analysis and Fourier transform infrared spectroscopy (FTIR) tests were performed to investigate the effects of WCO qualities on asphalt chemical composition. Finally, grey correlation coefficients were calculated and the relationships between WCO qualities and rejuvenated asphalt properties were quantitatively evaluated. The experimental results indicated that WCO qualities influence the rejuvenation behaviors of aged asphalt significantly, and the WCO with higher qualities (low acid value and viscosity, as defined in this research) tends to achieve better rejuvenation effects. Based on the results of grey correlation analyses, the acid value is, relatively, a better indicator than viscosity in predicting the rejuvenation efficiency of WCO. The rejuvenation thresholds of WCO are varied with the categories of properties of rejuvenated asphalts, and WCO with an acid value of 0.4–0.7 mg KOH/g, or a viscosity of 140–540 mm2/s, can meet all of the performance requirements for asphalt rejuvenation used in this research. PMID:28772862

  6. Effect of storage duration on the rheological properties of goose liquid egg products and eggshell membranes.

    PubMed

    Kumbar, V; Nedomova, S; Trnka, J; Buchar, J; Pytel, R

    2016-07-01

    In practice, goose eggs are increasingly used and, therefore, the rheological properties have to be known for processing. The eggs of geese (Landes Goose, Anser anser f. domestica) were stored for one, 2, 3, 4, 6, and 8 wk at a constant temperature 4°C. First of all, the egg quality parameters were described in terms of egg weight, egg weight loss, egg shape index, yolk height, albumen height, yolk index, albumen index, and Haugh units. In the next step the rheological behavior of liquid egg products (egg yolk, albumen, and whole liquid egg) was studied using a concentric cylinder viscometer. Flow curves of all liquid egg products exhibited non-Newtonian shear thinning behavior. This behavior can be described using the Herschel-Bulkley model and for technical application using the Ostwald-de Waele model. The effect of the storage duration on the rheological behavior is different for the different liquid egg products. With the exception of very low shear rates, the viscosity of the egg yolk as well as of the whole liquid egg decreases with storage time. At lower shear rates there is a tendency toward increased albumen viscosity with storage duration. The storage duration also affects the mechanical properties of the eggshell membrane. This effect has been evaluated in terms of the ultimate tensile strength, fracture strain, and fracture toughness. All these parameters increased with the loading rate, but decreased during the egg storage. These mechanical phenomena should be respected, namely in the design of the egg model for the numerical simulation of the egg behavior under different kinds of the mechanical loading. © 2016 Poultry Science Association Inc.

  7. Viscosity of Xenon Examined in Microgravity

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory A.; Berg, Robert F.; Moldover, Michael R.

    1999-01-01

    Why does water flow faster than honey? The short answer, that honey has a greater viscosity, merely rephrases the question. The fundamental answer is that viscosity originates in the interactions between a fluid s molecules. These interactions are so complicated that, except for low-density gases, the viscosity of a fluid cannot be accurately predicted. Progress in understanding viscosity has been made by studying moderately dense gases and, more recently, fluids near the critical point. Modern theories predict a universal behavior for all pure fluids near the liquid-vapor critical point, and they relate the increase in viscosity to spontaneous fluctuations in density near this point. The Critical Viscosity of Xenon (CVX) experiment tested these theories with unprecedented precision when it flew aboard the Space Shuttle Discovery (STS-85) in August 1997. Near the critical point, xenon is a billion times more compressible than water, yet it has about the same density. Because the fluid is so "soft," it collapses under its own weight when exposed to the force of Earth s gravity - much like a very soft spring. Because the CVX experiment is conducted in microgravity, it achieves a very uniform fluid density even very close to the critical point. At the heart of the CVX experiment is a novel viscometer built around a small nickel screen. An oscillating electric field forces the screen to oscillate between pairs of electrodes. Viscosity, which dampens the oscillations, can be calculated by measuring the screen motion and the force applied to the screen. So that the fluid s delicate state near the critical point will not be disrupted, the screen oscillations are set to be both slow and small.

  8. Analysis of the Relationships between Waste Cooking Oil Qualities and Rejuvenated Asphalt Properties.

    PubMed

    Zhang, Dong; Chen, Meizhu; Wu, Shaopeng; Liu, Jingxiang; Amirkhanian, Serji

    2017-05-06

    Waste cooking oil (WCO), in many cases, can rejuvenate aged asphalt and restore its properties. However, the influence of WCO qualities on rejuvenation behaviors of aged asphalt has not been investigated in detail. The objective of this paper was to evaluate the effects of WCO viscosity and acid value on the basic, rheological, and chemical properties of a typical rejuvenated asphalt. Penetration, ring and ball (R and B) softening point, and ductility were tested to evaluate the influence of WCO qualities on basic properties of rejuvenated asphalts. Then, the rheological properties of rejuvenated asphalt were characterized based on rotational viscometer (RV), dynamic shear rheometer (DSR), and bending beam rheometer (BBR) test results. Further, SARA (saturates, aromatics, resins, and asphaltenes) fraction analysis and Fourier transform infrared spectroscopy (FTIR) tests were performed to investigate the effects of WCO qualities on asphalt chemical composition. Finally, grey correlation coefficients were calculated and the relationships between WCO qualities and rejuvenated asphalt properties were quantitatively evaluated. The experimental results indicated that WCO qualities influence the rejuvenation behaviors of aged asphalt significantly, and the WCO with higher qualities (low acid value and viscosity, as defined in this research) tends to achieve better rejuvenation effects. Based on the results of grey correlation analyses, the acid value is, relatively, a better indicator than viscosity in predicting the rejuvenation efficiency of WCO. The rejuvenation thresholds of WCO are varied with the categories of properties of rejuvenated asphalts, and WCO with an acid value of 0.4-0.7 mg KOH/g, or a viscosity of 140-540 mm²/s, can meet all of the performance requirements for asphalt rejuvenation used in this research.

  9. Fabrication and Characterization of Dense Zirconia and Zirconia-Silica Ceramic Nanofibers

    PubMed Central

    Guo, Guangqing; Fan, Yuwei

    2011-01-01

    The objective of this study was to prepare dense zirconia-yttria (ZY), zirconia-silica (ZS) and zirconia-yttria-silica (ZYS) nanofibers as reinforcing elements for dental composites. Zirconium (IV) propoxide, yttrium nitrate hexahydrate, and tetraethyl orthosilicate (TEOS) were used as precursors for the preparation of zirconia, yttria, and silica sols. A small amount (1–1.5 wt%) of polyethylene oxide (PEO) was used as a carry polymer. The sols were preheated at 70 °C before electrospinning and their viscosity was measured with a viscometer at different heating time. The gel point was determined by viscosity–time (η–t) curve. The ZY, ZS and ZYS gel nanofibers were prepared using a special reactive electrospinning device under the conditions near the gel point. The as-prepared gel nanofibers had diameters between 200 and 400 nm. Dense (nonporous) ceramic nanofibers of zirconia-yttria (96/4), zirconia-silica (80/20) and zirconia-yttria-silica (76.8/3.2/20) with diameter of 100–300 nm were obtained by subsequent calcinations at different temperatures. The gel and ceramic nanofibers obtained were characterized by scanning electron microscope (SEM), high-resolution field-emission scanning electron microscope (FE-SEM), thermogravimetric analyzer (TGA), differential scanning calorimeter (DSC), Fourier transform infrared spectrometer (FT-IR), and X-ray diffraction (XRD). SEM micrograph revealed that ceramic ZY nanofibers had grained structure, while ceramic ZS and ZYS nanofibers had smooth surfaces, both showing no visible porosity under FE-SEM. Complete removal of the polymer PEO was confirmed by TGA/DSC and FT-IR. The formation of tetragonal phase of zirconia and amorphous silica was proved by XRD. In conclusion, dense zirconia-based ceramic nanofibers can be fabricated using the new reactive sol–gel electrospinning technology with minimum organic polymer additives. PMID:21133090

  10. Role of hemolysis in red cell adenosine triphosphate release in simulated exercise conditions in vitro.

    PubMed

    Mairbäurl, Heimo; Ruppe, Florian A; Bärtsch, Peter

    2013-10-01

    Specific adenosine triphosphate (ATP) release from red blood cells has been discussed as a possible mediator controlling microcirculation in states of decreased tissue oxygen. Because intravascular hemolysis might also contribute to plasma ATP, we tested in vitro which portion of ATP release is due to hemolysis in typical exercise-induced strains to the red blood cells (shear stress, deoxygenation, and lactic acidosis). Human erythrocytes were suspended in dextran-containing media (hematocrit 10%) and were exposed to shear stress in a rotating Couette viscometer at 37°C. Desaturation (oxygen saturation of hemoglobin ∼20%) was achieved by tonometry with N2 before shear stress exposure. Cells not exposed to shear stress were used as controls. Na lactate (15 mM), lactic acid (15 mM, pH 7.0), and HCl (pH 7.0) were added to simulate exercise-induced lactic acidosis. After incubation, extracellular hemoglobin was measured to quantify hemolysis. ATP was measured with the luciferase assay. Shear stress increased extracellular ATP in a stress-related and time-dependent manner. Hypoxia induced a ∼10-fold increase in extracellular ATP in nonsheared cells and shear stress-exposed cells. Lactic acid had no significant effect on ATP release and hemolysis. In normoxic cells, approximately 20%-50% of extracellular ATP was due to hemolysis. This proportion decreased to less than 10% in hypoxic cells. Our results indicate that when exposing red blood cells to typical strains they encounter when passing through capillaries of exercising skeletal muscle, ATP release from red blood cells is caused mainly by deoxygenation and shear stress, whereas lactic acidosis had only a minor effect. Hemolysis effects were decreased when hemoglobin was deoxygenated. Together, by specific release and hemolysis, extracellular ATP reaches values that have been shown to cause local vasodilatation.

  11. NASA Tech Briefs, September 2010

    NASA Technical Reports Server (NTRS)

    2010-01-01

    Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

  12. Time-Dependent Effect of Refrigeration on Viscosity and Conversion Kinetics of Dental Adhesive Resins

    PubMed Central

    Faria-e-Silva, André L; Piva, Evandro; Moraes, Rafael R

    2010-01-01

    Objectives: This study evaluated the effect of refrigeration at 4°C and post-refrigeration times (immediate, 5, 10, 15, or 20 min) on the viscosity and conversion kinetics of adhesive bonding resins. Methods: Scotchbond Dual-Cure (3M ESPE) and Clearfil SE Bond (Kuraray) were tested. Control samples were kept at 25°C for 24 h. At each post-refrigeration time, the temperature was checked with a K-type thermocouple. Viscosity measurements as a function of temperature were performed using a cone-plate viscometer. Real-time polymerization was monitored by infrared spectroscopy. Degree of conversion (DC) was calculated for each second during polymerization, and the rate of polymerization analyzed. Data were separately submitted to two-way ANOVA and Tukey’s test (P<.05). Results: Clearfil presented faster increase in temperature after exposure to room temperature than Scotchbond. A continuous decrease in viscosity (Pa.s) was observed for both Scotchbond (0.49, 0.34, 0.30, 0.26, 0.23, 0.23) and Clearfil (0.38, 0.37, 0.34, 0.25, 0.24, 0.22). For Scotchbond, higher final DC was detected for the control (62.7%) compared with the immediate (53.3%) and 5 min (54.7%) groups. For Clearfil, the control sample (81.4%) showed higher DC than all refrigerated groups (68.8–69.5%). Clearfil always showed significantly higher DC than Scotchbond. Conclusions: Refrigeration presented a significant time- and material-dependent effect on the viscosity and polymerization kinetics of the bonding resins. Under clinical conditions, adhesive agents should be removed from the refrigerator at least 20 min before being used. PMID:20396445

  13. Hydroxyapatite, fluor-hydroxyapatite and fluorapatite produced via the sol-gel method. Optimisation, characterisation and rheology.

    PubMed

    Tredwin, Christopher J; Young, Anne M; Georgiou, George; Shin, Song-Hee; Kim, Hae-Won; Knowles, Jonathan C

    2013-02-01

    Currently, most titanium implant coatings are made using hydroxyapatite and a plasma spraying technique. There are however limitations associated with plasma spraying processes including poor adherence, high porosity and cost. An alternative method utilising the sol-gel technique offers many potential advantages but is currently lacking research data for this application. It was the objective of this study to characterise and optimise the production of Hydroxyapatite (HA), fluorhydroxyapatite (FHA) and fluorapatite (FA) using a sol-gel technique and assess the rheological properties of these materials. HA, FHA and FA were synthesised by a sol-gel method. Calcium nitrate and triethylphosphite were used as precursors under an ethanol-water based solution. Different amounts of ammonium fluoride (NH4F) were incorporated for the preparation of the sol-gel derived FHA and FA. Optimisation of the chemistry and subsequent characterisation of the sol-gel derived materials was carried out using X-ray Diffraction (XRD) and Differential Thermal Analysis (DTA). Rheology of the sol-gels was investigated using a viscometer and contact angle measurement. A protocol was established that allowed synthesis of HA, FHA and FA that were at least 99% phase pure. The more fluoride incorporated into the apatite structure; the lower the crystallisation temperature, the smaller the unit cell size (changes in the a-axis), the higher the viscosity and contact angle of the sol-gel derived apatite. A technique has been developed for the production of HA, FHA and FA by the sol-gel technique. Increasing fluoride substitution in the apatite structure alters the potential coating properties. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  14. Shear stress and flow dynamics of the femoral vein among obese patients who qualify for bariatric surgery.

    PubMed

    Wiewiora, Maciej; Piecuch, Jerzy; Glűck, Marek; Slowinska-Lozynska, Ludmila; Sosada, Krystyn

    2013-01-01

    The aim of this study was to evaluate the effects of obesity on wall shear stress and its relationship to erythrocyte aggregation. We studied 35 morbidly obese patients who were qualified for bariatric surgery. The control group consisted of 20 non-obese people. Blood rheological measurements were performed using the Laser-assisted Optical Rotational Cell Analyzer (Mechatronics, the Netherlands) and a cone-plate viscometer (Brookfield DV-II). The venous flow dynamics were assessed using a duplex ultrasound. The shear rate was estimated from the measured blood flow velocity and the diameter of the femoral vein. Venous wall shear stress was calculated from the whole blood viscosity and the shear rate. The shear rate (P < 0.005) and the venous wall shear stress (P < 0.05) were significantly lower in obese patients compared with the controls. The aggregation index (P < 0.001), syllectogram amplitude - AMP (P < 0.05) and Tslow (P < 0.001) were significantly higher in the obese patients; the aggregation half-time (P < 0.001) and Tfast (P < 0.001) were decreased compared with the control group. Multivariate regression analyses found waist circumference (β -0.31, P < 0.05), thigh circumference (β 0.33, P < 0.05) and Tslow (β -0.47, P < 0.005) to be variables that independently influenced the shear rate. Nevertheless, the AMP (β 0.34, P < 0.05) and Tslow (β -0.47, P < 0.01) were independent predictors that influenced the wall shear stress. This study indicates that there is a relationship between wall shear stress in the femoral vein and the rheological impairment of the RBC among obese patients, but further studies are necessary to confirm this suggestion.

  15. Effects of low temperature on shear-induced platelet aggregation and activation.

    PubMed

    Zhang, Jian-ning; Wood, Jennifer; Bergeron, Angela L; McBride, Latresha; Ball, Chalmette; Yu, Qinghua; Pusiteri, Anthony E; Holcomb, John B; Dong, Jing-fei

    2004-08-01

    Hemorrhage is a major complication of trauma and often becomes more severe in hypothermic patients. Although it has been known that platelets are activated in the cold, studies have been focused on platelet behavior at 4 degrees C, which is far below temperatures encountered in hypothermic trauma patients. In contrast, how platelets function at temperatures that are commonly found in hypothermic trauma patients (32-37 degrees C) remains largely unknown, especially when they are exposed to significant changes in fluid shear stress that could occur in trauma patients due to hemorrhage, vascular dilation/constriction, and fluid resuscitation. Using a cone-plate viscometer, we have examined platelet activation and aggregation in response to a wide range of fluid shear stresses at 24, 32, 35, and 37 degrees C. We found that shear-induced platelet aggregation was significantly increased at 24, 32, and 35 degrees C as compared with 37 degrees C and the enhancement was observed in whole blood and platelet-rich plasma. In contrast to observation made at 4 degrees C, the increased shear-induced platelet aggregation at these temperatures was associated with minimal platelet activation as determined by the P-selectin expression on platelet surface. Blood viscosity was also increased at low temperature and the changes in viscosity correlated with levels of plasma total protein and fibrinogen. We found that platelets are hyper-reactive to fluid shear stress at temperatures of 24, 32, and 35 degrees C as compared with at 37 degrees C. The hyperreactivity results in heightened aggregation through a platelet-activation independent mechanism. The enhanced platelet aggregation parallels with increased whole blood viscosity at these temperatures, suggesting that enhanced mechanical cross-linking may be responsible for the enhanced platelet aggregation.

  16. Transport properties of nonelectrolyte liquid mixtures—II. Viscosity coefficients for the n-hexane + n-hexadecane system at temperatures from 25 to 100‡C at pressures up to the freezing pressure or 500 MPa

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Young, K. J.; Isdale, J. D.

    1980-12-01

    Viscosity coefficients measured with an estimated accuracy of 2% using a self-centering falling body viscometer are reported for n-hexane, n-hexadecane, and four binary mixtures at 25, 50, 75, and 100‡C at pressures up to the freezing pressure or 500 MPa. The data for a given composition at different temperatures and pressures are very satisfactorily correlated by a plot of Ή, defined as 104 ηV 2/3/( MT)1/2 in the cgs system of units, or generally, 9.118×107 η V 2/3/( MRT)1/2, versus log V', as suggested by the hard-sphere theories, where V' = V · V 0( T R)/ V 0( T) and V 0 represents the close-packed volume at temperature T and reference temperature T R . The experimental results for all compositions are fitted, generally well within the estimated uncertainty, by the equation 1 10765_2004_Article_BF00516563_TeX2GIFE1.gif ln η ' = {text{ - 1}}{text{.0 + }}{BV_0 }/{V - V_0 } where B and V 0 are temperature and composition dependent. Values of B and V 0 for the mixtures are simply related to values for the pure liquids, and viscosity coefficients calculated on the basis of this equation have an estimated accuracy of 3%. The effectiveness of the recently recommended empirical Grunberg and Nissan equation is investigated. It is found that the parameter G is pressure dependent, as well as composition dependent, but is practically temperature independent.

  17. Stereoisomeric effects on dynamic viscosity versus pressure and temperature for the system cis- + trans-decalin

    NASA Astrophysics Data System (ADS)

    Miyake, Yasufumi; Boned, Christian; Baylaucq, Antoine; Bessières, David; Zéberg-Mikkelsen, Claus K.; Galliéro, Guillaume; Ushiki, Hideharu

    2007-07-01

    In order to study the influence of stereoisomeric effects on the dynamic viscosity, an extensive experimental study of the viscosity of the binary system composed of the two stereoisomeric molecular forms of decalin - cis and trans - has been carried out for five different mixtures at three temperatures (303.15, 323.15 and 343.15) K and six isobars up to 100 MPa with a falling-body viscometer (a total of 90 points). The experimental relative uncertainty is estimated to be 2%. The variations of dynamic viscosity versus composition are discussed with respect to their behavior due to stereoisomerism. Four different models with a physical and theoretical background are studied in order to investigate how they take the stereoisomeric effect into account through their required model parameters. The evaluated models are based on the hard-sphere scheme, the concepts of the free-volume and the friction theory, and a model derived from molecular dynamics. Overall, a satisfactory representation of the viscosity of this binary system is found for the different models within the considered ( T, p) range taken into account their simplicity. All the models are able to distinguish between the two stereoisomeric decalin compounds. Further, based on the analysis of the model parameters performed on the pure compounds, it has been found that the use of simple mixing rules without introducing any binary interaction parameters are sufficient in order to predict the viscosity of cis + trans-decalin mixtures with the same accuracy in comparison with the experimental values as obtained for the pure compounds. In addition to these models, a semi-empirical self-referencing model and the simple mixing laws of Grunberg-Nissan and Katti-Chaudhri are also applied in the representation of the viscosity behavior of these systems.

  18. Transport properties of nonelectrolyte liquid mixtures—III. Viscosity coefficients for n-octane, n-dodecane, and equimolar mixtures of n-octane + n-dodecane and n-hexane + n-dodecane from 25 to 100°C at pressures up to the freezing pressure or 500 MPa

    NASA Astrophysics Data System (ADS)

    Dymond, J. H.; Robertson, J.; Isdale, J. D.

    1981-06-01

    Viscosity coefficients measured with an estimated accuracy of 2% using a new design of self-centering falling body viscometer are reported for n-octane, n-dodecane, and equimolar mixtures of n-octane + n-dodecane and n-hexane + n-dodecane at 25, 50, 75, and 100°C at pressures up to the freezing pressure or 500 MPa. The data for a given composition at different temperatures and pressures are very satisfactorily correlated by a plot of ή, defined as 104ηV2/3/( MT)1/2 in the cgs system of units or, generally, 9.118×107ηV2/3/( MRT)1/2, versus log V', where V' = V · V 0( T R)/ V 0( T) and V 0 represents the close-packed volume at temperature T and reference temperature T R. The experimental results are fitted, generally well within the estimated uncertainty, by the equation 10765_2004_Article_BF00503937_TeX2GIFE1.gif ln η ' = - 1.0 + {BV_0 }/{V - V_0 } , where B and V 0 are temperature and composition dependent. Values of B and V 0 for the mixtures are simply related to values for the pure liquids. The binary mixing rule of Grunberg and Nissan is investigated. Values of the mixing parameter G are positive, tend to increase with increases in pressure, and also increase with increases in difference in carbon number of the two pure components.

  19. Impaired viscosity of gastric secretion and its mucin content as potential contributing factors to the development of chronic constipation.

    PubMed

    Castro-Combs, Juan; Garcia, Cesar J; Majewski, Marek; Wallner, Grzegorz; Sarosiek, Jerzy

    2014-11-01

    The alimentary tract mucosa continuously releases mucus-rich secretion. Mucin, the major component of mucus, determines its viscosity and provides lubrication for the luminal content of indigestible food particles. To measure mucin secretion rate and its viscosity in patients with chronic constipation (CC) and in asymptomatic volunteers. Nineteen patients with symptoms of CC and 19 controls were included in the study. Mucin secretion and viscosity were assessed in aspirated gastric juice in basal conditions and after stimulation with pentagastrin (1 h each). Mucin content was tested by PAS methodology. Viscosity was measured using cone/plate digital viscometer. Mucin secretion rates in basal and stimulated conditions in controls were 65 and 42 % higher than in patients with CC (P < 0.05 and P < 0.001, respectively). Basal viscosity in controls was 48 % higher than in CC (P < 0.05) at the lowest and 55 % higher (P < 0.05) at the middle velocities. Viscosity in pentagastrin-stimulated conditions in controls was 71 % higher than in CC (P < 0.01) at the lowest and 35 % higher (P < 0.05) at the middle velocities. (1) The significantly lower rate of soluble mucin secretion in patients with CC than in normal volunteers may reflect impairment in mucin-related lubrication. (2) Significantly lower viscosity of gastric secretion in patients with CC may result from the lower rate of mucin secretion and may also diminish lubrication within the alimentary tract. (3) This may potentially set the stage for the development of symptoms related to chronic constipation and open a new therapeutic avenue for this patient population.

  20. Microthrix parvicella abundance associates with activated sludge settling velocity and rheology - Quantifying and modelling filamentous bulking.

    PubMed

    Wágner, Dorottya S; Ramin, Elham; Szabo, Peter; Dechesne, Arnaud; Plósz, Benedek Gy

    2015-07-01

    The objective of this work is to identify relevant settling velocity and rheology model parameters and to assess the underlying filamentous microbial community characteristics that can influence the solids mixing and transport in secondary settling tanks. Parameter values for hindered, transient and compression settling velocity functions were estimated by carrying out biweekly batch settling tests using a novel column setup through a four-month long measurement campaign. To estimate viscosity model parameters, rheological experiments were carried out on the same sludge sample using a rotational viscometer. Quantitative fluorescence in-situ hybridisation (qFISH) analysis, targeting Microthrix parvicella and phylum Chloroflexi, was used. This study finds that M. parvicella - predominantly residing inside the microbial flocs in our samples - can significantly influence secondary settling through altering the hindered settling velocity and yield stress parameter. Strikingly, this is not the case for Chloroflexi, occurring in more than double the abundance of M. parvicella, and forming filaments primarily protruding from the flocs. The transient and compression settling parameters show a comparably high variability, and no significant association with filamentous abundance. A two-dimensional, axi-symmetrical computational fluid dynamics (CFD) model was used to assess calibration scenarios to model filamentous bulking. Our results suggest that model predictions can significantly benefit from explicitly accounting for filamentous bulking by calibrating the hindered settling velocity function. Furthermore, accounting for the transient and compression settling velocity in the computational domain is crucial to improve model accuracy when modelling filamentous bulking. However, the case-specific calibration of transient and compression settling parameters as well as yield stress is not necessary, and an average parameter set - obtained under bulking and good settling conditions - can be used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Hydrodynamic shear shows distinct roles for LFA-1 and Mac-1 in neutrophil adhesion to intercellular adhesion molecule-1.

    PubMed

    Neelamegham, S; Taylor, A D; Burns, A R; Smith, C W; Simon, S I

    1998-09-01

    The binding of neutrophil beta2 integrin to intercellular adhesion molecule-1 (ICAM-1) expressed on the inflamed endothelium is critical for neutrophil arrest at sites of tissue inflammation. To quantify the strength and kinetics of this interaction, we measured the adhesion between chemotactically stimulated neutrophils and ICAM-1-transfected mouse cells (E3-ICAM) in suspension in a cone-plate viscometer at shear rates typical of venular blood flow (100 s-1 to 500 s-1). The kinetics of aggregation were fit with a mathematical model based on two-body collision theory. This enabled estimation of adhesion efficiency, defined as the probability with which collisions between cells resulted in firm adhesion. The efficiency of beta2-integrin-dependent adhesion was highest ( approximately 0.2) at 100 s-1 and it decreased to approximately zero at 400 s-1. Both LFA-1 and Mac-1 contributed equally to adhesion efficiency over the initial 30 seconds of stimulation, but adhesion was entirely Mac-1-dependent by 120 seconds. Two hydrodynamic parameters were observed to influence integrin-dependent adhesion efficiency: the level of shear stress and the intercellular contact duration. Below a critical shear stress (<2 dyn/cm2), contact duration predominantly limited adhesion efficiency. The estimated minimum contact duration for beta2-integrin binding was approximately 6.5 ms. Above the critical shear stress (>2 dyn/cm2), the efficiency of neutrophil adhesion to E3-ICAM was limited by both the contact duration and the tensile stress. We conclude that at low shear, neutrophil adhesion is modulated independently through either LFA-1 or Mac-1, which initially contribute with equal efficiency, but differ over the duration of chemotactic stimulation. Copyright 1998 by The American Society of Hematology.

  2. Physical Properties of Blood Are Altered in Young and Lean Women with Polycystic Ovary Syndrome.

    PubMed

    Simmonds, Michael J; Milne, Nikki; Ong, Kee; Brotherton, Emily; McNamee, Antony P; Horobin, Jarod; Sabapathy, Surendran

    2016-01-01

    Classic features of polycystic ovary syndrome (PCOS) include derangement of metabolic and cardiovascular health, and vascular dysfunction is commonly reported. These comorbidities indicate impaired blood flow; however, other than limited reports of increased plasma viscosity, surprisingly little is known regarding the physical properties of blood in PCOS. We aimed to investigate whether haemorheology was impaired in women with PCOS. We thus measured a comprehensive haemorheological profile, in a case-control design, of lean women with PCOS and age-matched healthy controls. A clinical examination determined similar cardiovascular risk for the two groups. Whole blood and plasma viscosity was measured using a cone-plate viscometer. The magnitude and rate of red blood cell (RBC) aggregation was determined using a light-transmission aggregometer, and the degree of RBC deformability was measured via laser-diffraction ektacytometry. Plasma viscosity was significantly increased in women with PCOS. Blood viscosity was also increased for PCOS at lower-to-moderate shear rates in both native and standardised haematocrit samples. The magnitude of RBC aggregation-a primary determinant of low-shear blood viscosity-was significantly increased in PCOS at native and 0.4 L·L-1 haematocrit. No difference was detected between PCOS and CON groups for RBC deformability measurements. A novel measure indicating the effectiveness of oxygen transport by RBC (i.e., the haematocrit-to-viscosity ratio; HVR) was decreased at all shear rates in women with PCOS. In a group of young and lean women with PCOS with an unremarkable cardiovascular risk profile based on clinical data, significant haemorheological impairment was observed. The degree of haemorheological derangement observed in the present study reflects that of overt chronic disease, and provides an avenue for future therapeutic intervention in PCOS.

  3. Viscosity Determination of Molten Ash from Low-Grade US Coals

    DOE PAGES

    Zhu, Jingxi; Nakano, Jinichiro; Kaneko, Tetsuya Kenneth; ...

    2012-10-01

    In entrained slagging gasifiers, the fluidity of the molten ash is a critical factor for process control since it affects slag formation, the capture of inorganic constituents, refractory wear, and slag drainage along the gasification chamber walls. The use of western coal, or mixtures of eastern and western coals as gasifier feedstock, is likely to occur as western coals become available and technological issues that hinder their use are being resolved. In the present work, the viscosity of synthetic slags with ash chemistries simulating the western U.S. coals, was experimentally measured at a Po 2 = 10 - 8 atmmore » in the temperature range of 1773–1573 K (1500–1300 °C) using a rotating-bob viscometer. Alumina spindles and containment crucibles of both alumina and zirconia were used. Crystallization studies of this slag using a confocal scanning laser microscope found that a (Mg,Fe)Al 2O 4-based spinel precipitated at temperatures below 1723 K (1450 °C), and this agreed with FactSage equilibrium phase prediction. The same spinels were observed in the post-viscometry experiment slags when ZrO 2 crucibles were used and assumed to be in equilibrium with the slag at the higher temperatures. Zirconia dissolution resulted in a slight increase in the solid fraction present in slags at lower temperatures, compared to spinel fraction. Crystal precipitation changed the apparent activation energy and required a longer stabilization times for viscosity measurements. The viscosity results were used in predictive equations based on Veytsman and Einstein's models, with critical nucleation temperatures and the solid fraction calculated with FactSage. In the simulated eastern/western coal feedstock blends based on ash compositions, the fractions of the solid precipitates were also calculated using the thermodynamic program FactSage for each blend composition, and the plastic viscosity of each eastern/western coal slag blend was predicted using Veytsman's model and compared to available experimental data.« less

  4. Technological and safety properties display biodiversity among enterococci isolated from two Egyptian cheeses, "Ras" and "Domiati".

    PubMed

    Malek, Reine; El-Attar, Aisha; Mohamed, Mariam; Anwar, Shimaa; El-Soda, Morsi; Béal, Catherine

    2012-02-15

    The technological and safety properties of 35 indigenous strains of Enterococcus faecium isolated from two Egyptian cheeses were characterised in order to determine their ability for rational manufacture of diversified and typical dairy products in the Middle East. A great diversity was observed within the 35 strains on the basis of their technological properties. A statistical analysis made it possible to distribute the 35 strains of E. faecium into different groups. Three groups were identified in terms of their acidification activity, measured by the Cinac system: a group of strains that quickly acidified milk, a second that moderately acidified milk, and a last cluster that revealed weak acidification activity. On the basis of texturing properties that were evaluated using a texturometer and a viscometer, a cluster of strains produced viscous and firm gels, a second cluster included fairly viscous, firm and cohesive gels, and a last group generated slightly viscous, but firm and very cohesive gels. By considering the aroma profiles that were determined by gas chromatography coupled with mass spectrometry, four clusters were identified. One cluster displayed a high dimethyl disulfide level, a second group of strains was highly aromatic, a third cluster led to typical "lactic" products, and the last cluster made it possible to obtain low aromatic products. None of the 35 strains proved to be β-haemolytic on the basis of the characterisation of their safety properties. The resistance to 20 antibiotics was assessed by the disc diffusion method. The 35 isolates were sensitive to 12 antibiotics, and among them, one isolate was resistant to only two antibiotics (nalixidic acid and streptomycin). The resistance to eight antibiotics was strain-dependant. Finally, this study demonstrates that some indigenous strains of E. faecium displayed interesting technological properties for cheese manufacture, together with good safety characteristics. They could be useful for the manufacture of typical products in Egypt. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Dynamics of falling droplet and elongational properties of dilute nonionic surfactant solutions with drag-reducing ability

    NASA Astrophysics Data System (ADS)

    Tamano, Shinji; Ohashi, Yota; Morinishi, Yohei

    2017-05-01

    The dynamics of the falling droplet through a nozzle for dilute nonionic surfactant (oleyl-dimethylamine oxide, ODMAO) aqueous solutions with viscoelastic and drag-reducing properties were investigated at different concentrations of ODMAO solutions Cs = 500, 1000, and 1500 ppm by weight. The effects of the flow rate and tube outer diameter on the length of the filament, which was the distance between the tube exit and the lower end of a droplet at the instant when the droplet almost detached from the tube, were clarified by flow visualization measurements by a high-speed video camera. Two types of breaking-off processes near the base of the droplet and within the filament were classified by the Ohnesorge number Oh and the Weber number We. In the regime of the higher Oh and We, the length of the filament became drastically larger at Cs = 1000 and 1500 ppm, whose high spinnability represented the strong viscoelasticity of ODMAO solutions. In the case where the filament was broken up near the lower end of the neck and thinning in time, the thinning of the diameter of the filament was measured by a light-emitting diode micrometer. As for the elasto-capillary thinning of dilute nonionic surfactant solutions, the initial necking process was similar to that of Newtonian fluids and then followed the exponential thinning like polymer solutions. The apparent elongational viscosity of the dilute nonionic surfactant solution was evaluated in the elasto-capillary thinning regime, in which the elongation rate was almost constant. At Cs = 1000 and 1500 ppm, the Trouton ratio, which was the ratio of the apparent elongational viscosity to the shear viscosity, was found to be several orders of magnitude larger than that of Newtonian fluids, while the shear viscosity measured by the capillary viscometer was almost the same order of the Newtonian fluids. The higher elongational property would be closely related to the higher drag-reducing ability of dilute nonionic surfactant solutions.

  6. Direct Determination of the Dependence of the Surface Shear and Dilatational Viscosities on the Thermodynamic State of the Interface: Theoretical Foundations.

    PubMed

    Lopez; Hirsa

    1998-10-01

    Recent developments in nonlinear optical techniques for noninvasive probing of a surfactant influenced gas/liquid interface allow for the measurement of the surfactant surface concentration, c, and thus provide new opportunities for the direct determination of its intrinsic viscosities. Here, we present the theoretical foundations, based on the Boussinesq-Scriven surface model without the usual simplification of constant viscosities, for an experimental technique to directly measure the surface shear (µs) and dilatational (kappas) viscosities of a Newtonian interface as functions of the surfactant surface concentration. This ability to directly measure the surfactant concentration permits the use of a simple surface flow for the measurement of the surface viscosities. The requirements are that the interface must be nearly flat, and the flow steady, axisymmetric, and swirling; these flow conditions can be achieved in the deep-channel viscometer driven at relatively fast rates. The tangential stress balance on such an interface leads to two equations; the balance in the azimuthal direction involves only µs and its gradients, and the balance in the radial direction involves both µs and kappas and their gradients. By further exploiting recent developments in laser-based flow measuring techniques, the surface velocities and their gradients which appear in the two equations can be measured directly. The surface tension gradient, which appears in the radial balance equation, is incorporated from the equation of state for the surfactant system and direct measurements of the surfactant surface concentration distribution. The stress balance equations are then ordinary differential equations in the surface viscosities as functions of radial position, which can be readily integrated. Since c is measured as a function of radial position, we then have a direct measurement of µs and kappas as functions of c. Numerical computations of the Navier-Stokes equations are performed to determine the appropriate conditions to achieve the requisite secondary flow. Copyright 1998 Academic Press.

  7. Field and experimental constraints on the rheology of arc basaltic lavas: the January 2014 Eruption of Pacaya (Guatemala)

    NASA Astrophysics Data System (ADS)

    Soldati, A.; Sehlke, A.; Chigna, G.; Whittington, A.

    2016-06-01

    We estimated the rheology of an active basaltic lava flow in the field, and compared it with experimental measurements carried out in the laboratory. In the field we mapped, sampled, and recorded videos of the 2014 flow on the southern flank of Pacaya, Guatemala. Velocimetry data extracted from videos allowed us to determine that lava traveled at ˜2.8 m/s on the steep ˜45° slope 50 m from the vent, while 550 m further downflow it was moving at only ˜0.3 m/s on a ˜4° slope. Estimates of effective viscosity based on Jeffreys' equation increased from ˜7600 Pa s near the vent to ˜28,000 Pa s downflow. In the laboratory, we measured the viscosity of a representative lava composition using a concentric cylinder viscometer, at five different temperatures between 1234 and 1199 °C, with crystallinity increasing from 0.1 to 40 vol%. The rheological data were best fit by power law equations, with the flow index decreasing as crystal fraction increased, and no detectable yield strength. Although field-based estimates are based on lava characterized by a lower temperature, higher crystal and bubble fraction, and with a more complex petrographic texture, field estimates and laboratory measurements are mutually consistent and both indicate shear-thinning behavior. The complementary field and laboratory data sets allowed us to isolate the effects of different factors in determining the rheological evolution of the 2014 Pacaya flows. We assess the contributions of cooling, crystallization, and changing ground slope to the 3.7-fold increase in effective viscosity observed in the field over 550 m, and conclude that decreasing slope is the single most important factor over that distance. It follows that the complex relations between slope, flow velocity, and non-Newtonian lava rheology need to be incorporated into models of lava flow emplacement.

  8. The Setting Time of Polyether Impression Materials after Contact with Conventional and Experimental Gingival Margin Displacement Agents.

    PubMed

    Nowakowska, Danuta; Raszewski, Zbigniew; Ziętek, Marek; Saczko, Jolanta; Kulbacka, Julita; Więckiewicz, Włodzimierz

    2018-02-01

    The compatibility of chemical gingival margin displacement agents with polyether impression materials has not been determined. The aim of this study was to evaluate the setting time of polyether impression elastomers after contact with conventional and experimental gingival displacement agents. The study compared the setting time of two polyether impression materials: medium body (Impregum Penta Soft) and light body (Impregum Garant L DuoSoft) after contact with 10 gingival displacement agents, including 5 conventional astringents (10%, 20%, and 25% aluminum chloride, 25% aluminum sulfate, and 15.5% ferric sulfate) and 5 experimental adrenergics (0.1% and 0.01% HCl-epinephrine, 0.05% HCl-tetrahydrozoline, 0.05% HCl-oxymetazoline, and 10% HCl-phenylephrine). As many as 120 specimens (60 light body and 60 medium body) were mixed with 20 μl of each of 10 gingival displacement agents, and the time to achieve maximum viscosity was measured with a viscometer. The setting times of these specimens were compared with the control group of 12 specimens, which were polymerized without contact with the displacement agents. The experiments were performed in two environments: 23°C and 37°C (± 0.1°C). Individual and average polymerization time compatibility indices (PTCI) were calculated. Data were analyzed by 2-way ANOVA (α = 0.05). The evaluated chemical displacement agents from both groups changed the setting time of light- and medium-body PE. The negative individual PTCI values achieved astringent (20% aluminum chloride) with two PE in both temperature environments. The average PTCI values of the experimental displacement agents at laboratory and intraoral temperatures were significantly higher than the conventional agents. The present findings suggest that experimental retraction agents can be recommended clinically as gingival margin displacement agents with minimal effects on the setting time of medium- and light-body polyether impression materials; however, direct contact of chemical displacement agents and polyether impression materials can be avoided. © 2016 by the American College of Prosthodontists.

  9. Influence of viscosity and amine content on C==C conversion and color stability of experimental composites.

    PubMed

    Camargo, Fernanda Missio; Della Bona, Álvaro; Moraes, R R; Coutinho de Souza, C R; Schneider, Luis Felipe

    2015-05-01

    To investigate the influence of camphorquinone (CQ):amine ratio on the degree of CC conversion (DC) and color stability of experimental dental composites formulated with different co-monomer viscosities, indirectly determined by variations in the co-monomer ratios. Experimental composites were formulated in two different BisGMA:TEGDMA molar ratios (50:50 and 70:30). Viscosities were assessed with a viscometer. For each composite formulation, four different CQ:amine ratios were added: 1:1, 1:2, 1:3 or 1:4 mol%. Materials were loaded with 40 wt% of silanized glass particles. DC was determined by Fourier-transformed infrared spectroscopy with attenuated reflectance mode (ATR-FTIR). A spectrophotometer was used to measure the CIE L*a*b* color coordinates 24h after polymerization and after 2 months stored in water. Color changes (ΔE) were calculated. Data were statistically analyzed using analyses of variance (ANOVA), Tukey's and Student-t tests (α=0.05). The 50:50 BisGMA:TEGDMA co-monomer showed lower viscosity than 70:30. DC was affected by CQ:amine ratio, and not by the co-monomer viscosity, but the interaction between these two factors was significant. a* and b* coordinates were dependent on CQ:amine or BisGMA:TEGDMA ratios, while L* was not. b* values were directly related to the amount of amine in the formulation, regardless of co-monomer viscosity. ΔE was dependent on the amount of amine, but not on the viscosity of the material. DC was influenced by the CQ:amine ratio. The influence of viscosity on DC was dependent on the CQ:amine ratio and exhibited distinguished behavior. a* and b* coordinates were affected by CQ:amine and BisGMA:TEGDMA ratios. The color change (ΔE) was affected by CQ:amine ratio, but not by viscosity. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Effect of boron oxide addition on the viscosity-temperature behaviour and structure of phosphate-based glasses.

    PubMed

    Sharmin, Nusrat; Hasan, Muhammad S; Rudd, Chris D; Boyd, Daniel; Werner-Zwanziger, Ulrike; Ahmed, Ifty; Parsons, Andrew J

    2017-05-01

    In this study, nine phosphate-based glass formulations from the system P 2 O 5 -CaO-Na 2 O-MgO-B 2 O 3 were prepared with P 2 O 5 content fixed as 40, 45 and 50 mol%, where Na 2 O was replaced by 5 and 10 mol% B 2 O 3 and MgO and CaO were fixed to 24 and 16 mol%, respectively. The effect of B 2 O 3 addition on the viscosity-temperature behaviour, fragility index and structure of the glasses was investigated. The composition of the glasses was confirmed by ICP-AES. The viscosity-temperature behaviour of the glasses were measured using beam-bending and parallel -plate viscometers. The viscosity of the glasses investigated was found to shift to higher temperature with increasing B 2 O 3 content. The kinetic fragility parameter, m and F 1/2 , estimated from the viscosity curve were found to decease with increasing B 2 O 3 content. The structural analysis was achieved by a combination of Fourier transform infrared spectroscopy and solid state nuclear magnetic resonance. 31 P solid-state magic-angle-spinning nuclear magnetic resonance (MAS-NMR) showed that the local structure of the glasses changes with increasing B 2 O 3 content. As B 2 O 3 was added to the glass systems, the phosphate connectivity increases as the as the Q 1 units transforms into Q 2 units. The 11 B NMR results confirmed the presence of tetrahedral boron (BO 4 ) units for all the compositions investigated. Structural analysis indicates an increasing level of cross-linking with increasing B 2 O 3 content. Evidence of the presence of P-O-B bonds was also observed from the FTIR and 31 P NMR analysis. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 764-777, 2017. © 2016 Wiley Periodicals, Inc.

  11. Effects of molecular weight of hyaluronic acid on its viscosity and enzymatic activities of lysozyme and peroxidase.

    PubMed

    Kim, Jihoon; Chang, Ji-Youn; Kim, Yoon-Young; Kim, Moon-Jong; Kho, Hong-Seop

    2018-05-01

    To investigate the effects of the molecular weight of hyaluronic acid on its viscosity and enzymatic activities of lysozyme and peroxidase in solution and on the hydroxyapatite surface. Hyaluronic acids of four different molecular weights (10 kDa, 100 kDa, 1 MDa, and 2 MDa), hen egg-white lysozyme, bovine lactoperoxidase, and human whole saliva were used. Viscosity values of hyaluronic acids were measured using a cone-and-plate viscometer at six different concentrations (0.1-5.0 mg/mL). Enzymatic activities of lysozyme and peroxidase were examined by hydrolysis of fluorescein-labeled Micrococcus lysodeikticus and oxidation of fluorogenic 2',7'-dichlorofluorescein to fluorescing 2',7'-dichlorofluorescein, respectively. In solution assays, only 2 MDa-hyaluronic acid significantly inhibited lysozyme activities in saliva. In surface assays, hyaluronic acids inhibited lysozyme and peroxidase activities; the inhibitory activities were more apparent with high-molecular-weight ones in saliva than in purified enzymes. The 100 kDa-hyaluronic acid at 5.0 mg/mL, 1 MDa-one at 0.5 mg/mL, and 2 MDa-one at 0.2 mg/mL showed viscosity values similar to those of human whole saliva at a shear rate range required for normal oral functions. The differences among the influences of the three conditions on the enzymatic activities were not statistically significant. High-molecular-weight hyaluronic acids at low concentration and low-molecular-weight ones at high concentration showed viscosity values similar to those of human whole saliva. Inhibitory effects of hyaluronic acids on lysozyme and peroxidase activities were more significant with high-molecular-weight ones on the surface and in saliva compared with in solution and on purified enzymes. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Crystal-rich lava dome extrusion during vesiculation: an experimental study

    NASA Astrophysics Data System (ADS)

    Pistone, M.; Whittington, A. G.; Andrews, B. J.; Cottrell, E.

    2016-12-01

    Lava dome-forming eruptions represent a common eruptive style and a major hazard on numerous active volcanoes worldwide. The influence of volatiles on the rheological mechanics of lava dome extrusion remains unclear. Here we present new experimental results on the rheology of synthesized, crystal-rich (50 to 80 vol% quartz crystals), hydrous (4.2 wt% H2O in the glass) dacites, which vesiculate from 5 to 27 vol% gas bubbles at high temperatures (483 to 797 °C) during deformation conducted in a parallel plate viscometer (constant stress at 0.64 MPa, and variable strain-rates ranging from 8.32•10-8 to 3.58•10-5 s-1). The experiments replicated lava dome deformation in volcanic conduits during vesiculation of the residual melt, instigated in the experiments by increasing temperature. During gas exsolution we find that the rheological lubrication of the system during deformation is strongly dictated by the imposed initial crystallinity. At low crystal content (< 60 vol%) strain localization within shear bands, composed of melt and gas bubbles that likely interconnect, controls the overall sample rheology. At high crystallinity (60 to 70 vol%) gas pressurization (i.e. pore pressure increase) within crystal clusters and embryonic formation of microscopic fractures drive the system to a brittle behavior. At higher crystallinity (80 vol%) gas pressurization triggers brittle fragmentation through macroscopic fractures, which sustain outgassing and determines the viscous death of the system. The contrasting behaviors at different crystallinities have direct impact on the style of volcanic eruptions. Outgassing induced by deformation and bubble coalescence reduces the system pressurization and the potential for an explosive eruption. Conversely, high crystallinity lava domes experience limited loss of exsolved gas during deformation, permitting the achievement of large overpressures prior to fragmentation, favoring likely explosive eruptions. These findings provide a dataset that might be used to constrain the physical properties of natural lava domes at active volcanoes and show how crystallinity and corresponding gas pressurization control dome growth rate and consequent eruption style.

  13. Physico-chemical characterization and pharmacological evaluation of sulfated polysaccharides from three species of Mediterranean brown algae of the genus Cystoseira.

    PubMed

    Hadj Ammar, Hiba; Lajili, Sirine; Ben Said, Rafik; Le Cerf, Didier; Bouraoui, Abderrahman; Majdoub, Hatem

    2015-01-13

    Seaweed polysaccharides are highly active natural substances having valuable applications. The present study was conducted to characterize the physico-chemical properties of sulphated polysaccharides from three Mediterranean brown seaweeds (Cystoseira sedoides, Cystoseira compressa and Cystoseira crinita) and to evaluate their anti-radical, anti-inflammatory and gastroprotective activities. The different rates of neutral sugars, uronic acids, L-fucose and sulphate content were determined by colorimetric techniques. The different macromolecular characteristics of isolated fucoidans were identified by size exclusion chromatography equipped with a triple detection: multiangle light scattering, viscometer and differential refractive index detectors, (SEC/MALS/VD/DRI). Anti-inflammatory activity was evaluated, using the carrageenan-induced rat paw edema test in comparison to the references drugs Acetylsalicylate of Lysine and Diclofenac. The gastroprotective activity was determined using HCl/EtOH induced gastric ulcers in rats and to examine the antioxidant effect of fucoidans in the three species, the free radical scavenging activity was determined using 1,1-diphenyl-2-picrylhydrazyl. The pharmacological evaluation of the isolated fucoidans for their anti-inflammatory, and their gastroprotective effect established that these products from C. sedoides, C. compressa and C. crinita exhibited a significant anti-inflammatory activity at a dose of 50 mg/kg, i.p; the percentages of inhibition of the oedema were 51%, 57% and 58% respectively. And, at the same dose, these fucoidans from C. sedoides and C. compressa showed a significant decrease of the intensity of gastric mucosal damages compared to a control group by 68%, whereas, the fucoidan from C. crinita produced a less gastroprotective effect. Furthermore, the isolated fucoidans exhibited a radical scavenging activity. The comparative study of fucoidans isolated from three species of the genus Cystoseira showed that they have similar chemicals properties and relatives anti-radical, anti-inflammatory and gastroprotective activities which are found to be promising.

  14. Study on the rheoformability of semi-solid 7075 wrought aluminum alloy using seed process =

    NASA Astrophysics Data System (ADS)

    Zhao, Qinfu

    Semisolid metal forming is becoming more and more attractive in the foundry industry due to its low cost and easy operation to produce high quality near-net-shape components. Over the past years, semisolid forming technique is mainly applied on the casting aluminum alloys due to their superior castability because of low melting temperature and viscosity. In semisolid forming field, thixoforming has been majorly used which involves of reheating the billet into semisolid state followed by casting process. Rheocasting is a more economic semisolid processing compared to thixoforming, which the semisolid billet is produced directly from liquid phase. The SEED process is one of reliable rheocasting techniques to produce high quality semisolid billets. To produce high quality semisolid billets, their unique rheological properties have been the most important issue need to be fully investigated. The aim of present project is to produce high quality semisolid AA7075 billets by SEED process and analyze their rheological properties under various process conditions. The effect of the SEED processing parameters and grain refiners on the semisolid microstructure and rheoformability were investigated. The deformation and rheological behavior of the semisolid billets of AA7075 base and its grain-refined alloys were studied using parallel-plate viscometer. In the first part, the evolution of liquid fraction to temperature of semisolid AA7075 alloy was investigated using Differential Scanning Calorimetry (DSC). It was found that the liquidus and solidus temperature of AA7075 alloy were 631 °C and 490°C respectively. And the corresponding temperatures of solid fraction of 40% and 60% were 622°C and 610°C, which was recognized as the temperature window for semisolid forming of this alloy. In the second part, the semisolid slurries were rheocasted using SEED technology and the effect of the SEED process parameters like swirling frequency and demolding temperature on evolution of microstructure was studied. It was found that the swirling frequency has a strong influence on the mean grain size and morphology of primary alpha-Al particles. With increasing swirling frequency, the mean size of alpha-Al particles first decreased significantly and then kept constant or increased slightly, due to the fragment and aggregation of solid particles. Microstructures also revealed that the alpha-Al particles tend to transform from dendrite-like to rosette-like to globular-like morphology due to the stirring movement. In the third part, the effects of TiB2 and Zr on the microstructure of semisolid AA7075 alloy were investigated. The microstructure observation and the intermetallic phase identification were carried out by optical microscopy equipped with Clemex analyzer and scanning electron microscopy (SEM). The mean size of primary alpha-Al particles decreases from more than 110 mum to less than 90 mum and the morphology changes from dendritic-like to globular-like with the addition of TiB2. With the addition of Zr or Zr + TiB 2, the mean size and morphology of primary alpha-Al particles didn't show significant modification. Furthermore, the addition of TiB2 shows significant refinement on three intermetallic phases (Mg(Zn,Cu,Al) 2, Fe-rich Al(Fe,Mn)Si and Mg2Si. All the intermetallic phases become finer in size and more uniform distribution among the grains. Finally, the rheological behavior and microstructure of deformed semisolid billets of AA7075 base and grain-refined alloys were investigated using parallel-plate viscometer. Images analysis shows that liquid segregates from center to edge of the billet during compression and with increasing temperature the liquid segregation becomes more significant. The apparent viscosity of two alloys decreases with the increasing shear rate, indicating shear thinning behavior. Shear rate jump phenomenon (first increase and then decrease) occurred at lower solid fraction, reaching a maximum shear rate value. The whole compression processing is divided into two parts: shear rate increasing part and shear rate decreasing part. For higher solid fraction, the shear rate decreases continuously and slowly. The attainable maximum shear rate value increases with the decreasing solid fraction. During the shear rate decreasing part, at any given shear rate the viscosity increases with the increasing solid fraction. The comparison of the viscosity of two alloys indicated that the TiB2-refined AA7075 alloy has lower viscosity (shear rate decreasing part) due to small grain size and globular grain shape. In addition, the grain refinement significantly expands the solid fraction range of good rheoformability from 42%-48% for the base alloy to 42%-55% for the refined alloy.

  15. Characterization of structural stability of palm oil esters-based nanocosmeceuticals loaded with tocotrienol

    PubMed Central

    2013-01-01

    Background Palm oil esters (POEs) are esters derived from palm oil and oleyl alcohol have great potential in the cosmetic and pharmaceutical industries due to the excellent wetting behavior of the esters without the oily feel. The role of oil-in-water nanoemulsions loaded with tocotrienol sedimentation behavior was studied. LUMiFuge® 116 particle separation analyzer was used to investigate the sedimentation behavior of POEs/tocotrienol/xanthan gum nanoemulsion system during centrifugation. Analyzing the sedimentation kinetics of dispersions in a centrifugal field also yields information about the rheological behavior and structural stability. Methods Experiments were performed in an analytical centrifuge at 11×g to 1140×g (LUMiFuge® 116 particle separation analyzer). The samples in the LUMiFuge® 116 particle separation analyzer were centrifuged at 3000 rpm for 15 h at 32°C. Sample volume of 2 cm3 was used. The rheological property of nanoemulsions was investigated using oscillatory measurements test. A rotational/oscillatory viscometer, Kinexus Rheometer (Malvern Instrument, UK) was used. All measurements were performed with a stainless steel cone-plate sensor at 25.0 ± 0.1°C with 4°/40 mm. Results The stable nanoemulsions showed sedimentation rates at earth gravity of 5.2, 3.0 and 2.6 mm/month for 10%, 20% and 30% (w/w) oil phase, respectively. Rheological behavior is an important target during the design of palm oil esters-based nanocosmeceuticals. The presence of a network structure was indicated by measurements which showed G’ to be greater than G”. This result implied the predominant elastic response and high storage stability of the nanoemulsion. It was also observed that the increase in oil phase concentration led to the profile which strongly indicated that the solid like elastic property; where the values of phase angle, δ of these nanoemulsions was lower than 45°. Conclusions The nanoemulsions with higher oil phase concentration (30% (w/w)) showed greater elasticity which implied strong dynamic rigidity of the nanoemulsion. It was the most stable with longest shelf-life. PMID:24059593

  16. What's in the mud?: Water-rock-microbe interactions in thermal mudpots and springs

    NASA Astrophysics Data System (ADS)

    Dahlquist, G. R.; Cox, A. D.

    2016-12-01

    Limited aspects of mudpot geochemistry, mineralogy, and microbiology have been previously investigated in a total of 58 mudpots in Yellowstone National Park (YNP), Kamchatka, Iceland, Italy, Valles Caldera, New Mexico, Nicaragua, and the Stefanos hydrothermal crater, Greece (Allen and Day, 1935; Raymahashay, 1968; Shevenell, 1987; Bradley, 2005; Prokofeva, 2006; Bortnikova, 2007; Kaasalainen, 2012; Szynkiewicz, 2012; Hynek, 2013; Pol, 2014; Kanellopoulos, 2016). The composition of 35 mudpots was analyzed for aqueous geochemistry of filtrate and solid phase characterization. Here mudpots are defined as thermal features with viscosities between 5 and 100 centipoise at the approximate temperature of the mudpot, which was measured by an Ofite hand cranked viscometer. Analogous samples of nearby hot springs provide comparisons between mudpots and non-viscous thermal features. Aqueous geochemistry from mudpots was obtained by a novel two-step filtration process consisting of gravity prefiltration by a 100 or 50 micron trace metal cleaned polyethylene bag filter followed by syringe filtration with 0.8/0.2 Supor membrane filters. This filtered sample water was preserved and analyzed for water isotopes, major anions and cations, dissolved organic carbon, and trace metals. Mudpot meter readings show dissolved oxygen values ranging from below the detection limit of 0.156 to 22.5uM, pH values ranging from 1.41 to 6.08, and temperatures ranging from 64.8 to 92.5°C. Mudpots and turbid hot springs exhibited an inverse relationship between dissolved rare earth element concentrations and dissolved calcium concentrations (where calcium concentrations > 0.4mM). Mudpots altered existing surficial geology to form clays, primarily kaolinite, montmorillionite, and alunite. This hydrothermal alteration leaches metals, allowing mudpots to concentrate metals. DNA was extracted from mudpot solids and amplified with eukaryotic, bacterial, archaeal, and universal primers, which yielded only bacterial and archaeal amplicons. Water, rock, and microbial communities interact to form diverse mudpots. The range of chemical conditions surveyed in YNP mudpots suggests varying underlying rock units, seasonal water variations, and sources of organic matter drastically affect geobiochemical characteristics.

  17. Novel bioadhesive polymers as intra-articular agents: Chondroitin sulfate-cysteine conjugates.

    PubMed

    Suchaoin, Wongsakorn; Bonengel, Sonja; Griessinger, Julia Anita; Pereira de Sousa, Irene; Hussain, Shah; Huck, Christian W; Bernkop-Schnürch, Andreas

    2016-04-01

    The aim of this study was to generate and characterize a chondroitin sulfate-cysteine conjugate (CS-cys) as a novel bioadhesive agent for intra-articular use. Mucoadhesive properties of synthesized CS-cys were investigated by rheological measurement of polymer-mucus mixture and rotating cylinder method, while bioadhesive features of CS-cys on porcine articular cartilage were evaluated via tensile studies. Thiolation was achieved by attachment of l-cysteine to CS via amide bond formation mediated by carbodiimide as a coupling reagent. The conjugate exhibited 421.17±35.14 μmol free thiol groups per gram polymer. The reduced CS-cys displayed 675.09±39.67 μmol free thiol groups per gram polymer after disulfide bonds reduction using tris(2-carboxyethyl)phosphine hydrochloride. The increase in dynamic viscosity of thiolated CS due to oxidative disulfide bond formation was demonstrated using capillary viscometer. The combination of CS-cys and mucus led to 4.57-fold increase in dynamic viscosity in comparison with mucus control. Furthermore, adhesion time to porcine mucosa of CS-cys-based test disk was enhanced by 2.48-fold compared to unmodified CS as measured by rotating cylinder method suggesting the interaction between thiomers and mucus gel layer via disulfide bonds formation. Tensile studies of thiolated CS on porcine articular cartilage showed 5.37- and 1.76-fold increase in the total work of adhesion and the maximum detachment force, respectively, in comparison with unmodified CS indicating bioadhesive features of CS-cys. Cytotoxicity of CS-cys was assessed in Caco-2 cells and rat primary articular chondrocytes using MTT and LDH release assay, thereby showing the safety of CS-cys at a concentration of 0.25% (w/v) in Caco-2 cells. Furthermore, 0.1% of CS-cys was found non-toxic to rat primary articular chondrocytes. According to these results, CS-cys provides improved bioadhesive properties that might be useful as an intra-articular agent for treatment of osteoarthritis. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Investigation of the erosive potential of sour novelty sweets.

    PubMed

    Aljawad, A; Morgan, M Z; Fairchild, R; Rees, J S

    2017-04-21

    Background The expansion of the novelty sweets market in the UK has major potential public health implications in children and young adults as they may cause dental erosion.Objective To investigate the erosive potential of the novelty sweets in term of their physiochemical properties and amount of enamel loss.Subjects and methods The pH of a variety of novelty sweets was tested in vitro using a pH meter and the neutralisable acidity was assessed by titrating the sweets against 0.1M NaOH. The viscosity of the novelty sweets was measured using a rotational viscometer. The wettability of enamel by each sweet was measured using dynamic contact angle analyser. Enamel loss was assessed using contact profilometry.Results The pH ranged from 1.8-3.2, the neutralisable acidity ranged from 9-201 ml of 0.1 NaOH. The viscosity of the novelty sweets that come in liquid form ranged from 2-594 mPa s. The surface enamel erosion ranged from 1.95-15.77 μm and from 2.5-17.6 μm with and without immersing in saliva for 1 hour before immersing in acidic solution respectively. The amount of subsurface enamel loss was ranged from 0.75 to 2.3 μm following ultrasonication at 0 min of acidic attack and from 0.23 to 0.85 μm at 60 minutes of acidic attack while immersed in saliva. The contact angle between enamel surface and four sweet was less than the angle formed between the orange juice and the enamel which caused more wettability of enamel.Conclusion The pH is lower than the critical value for enamel erosion (5.5), high neutralisable acidity and high sugar content strongly suggest that these sweets may cause significant amount of dental erosion clinically. In addition, the degree of wettability of enamel by solution is an important factor to consider in determining the enamel loss caused by acidic solution. Immediate tooth brushing would cause further enamel loss as a result of the mechanical removal of softened enamel. However, it has been suggested that postponing brushing after erosive attack should be reconsidered.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liuyun, Jiang, E-mail: jlytxg@163.com; Chengdong, Xiong; Lixin, Jiang

    Graphical abstract: In this manuscript, we initiated a systematic study to investigate the effect of HA on thermal properties, inner structure, reduction of mechanical strength, surface morphology and the surface deposit of n-HA/PLGA composite with respect to the soaking time. The results showed that n-HA played an important role in improving the degradation behavior of n-HA/PLGA composite, which can accelerate the degradation of n-HA/PLGA composite and endow it with bioactivity, after n-HA was detached from PLGA during the degradation, so that n-HA/PLGA composite may have a more promising prospect of the clinical application than pure PLGA as bone fracture internalmore » fixation materials, and the results would be of reference significance to predict the in vivo degradation and biological properties. - Highlights: • Effect of n-HA on degradation behavior of n-HA/PLGA composite was investigated. • Degradation behaviors of n-HA/PLGA and PLGA were carried out in SBF for 6 months. • Viscosity, thermal properties, inner structure and bending strength were tested. • n-HA can accelerate the degradation and endows it with bioactivity. - Abstract: To investigate the effect of hydroxyapatite(HA) on the degradation behavior of hydroxyapatite/poly(lactic-co-glycolic) acid (HA/PLGA) nanocomposite, the degradation experiment of n-HA/PLGA composite and pure PLGA were carried out by soaking in simulated body fluid(SBF) at 37 °C for 1, 2, 4 and 6 months. The change of intrinsic viscosity, thermal properties, inner structure, bending strength reduction, surface morphology and the surface deposit of n-HA/PLGA composite and pure PLGA with respect to the soaking time were investigated by means of UbbeloHde Viscometer, differential scanning calorimeter (DSC), scanning electron microscope(SEM), electromechanical universal tester, a conventional camera and X-ray diffraction (XRD). The results showed that n-HA played an important role in improving the degradation behavior of n-HA/PLGA composite, which can accelerate the degradation PLGA and endow it with bioactivity, after n-HA was detached from PLGA during the degradation, so that n-HA/PLGA composite may have a more promising prospect of the clinical application than pure PLGA as bone fracture internal fixation materials.« less

  20. Cyclic variation of ultrasonic backscattering from porcine whole blood under pulsatile flow

    NASA Astrophysics Data System (ADS)

    Lin, Yu-Hong

    1997-10-01

    The cyclic variation of ultrasonic backscattering from blood under pulsatile flow is believed to be related to the change of aggregation state of red cells and is only observed in whole blood. This study was to investigate the phenomenon by an invasive approach which was performed by inserting a 10 MHz catheter mounted transducer into a vessel. For ultrasonic measurement from blood, the most fundamental scheme is the hematocrit dependence. The backscatter maximum location was changed as the blood was stirred or stationary, as well as under steady laminar or turbulent flows. The same trend was also observed under pulsatile flow with 10% to 50% hematocrits in this study, as the backscattering to hematocrit curves were plotted at different times during a flow cycle. When the cyclic variation at 20 beats per minute (BPM) was interpreted in time domain, the enhanced aggregation at the beginning of shearing was observed. At 20 BPM with 40% hematocrit, the amplitude of cyclic variation was reduced when the shear rate was increased and the threshold of 150 s-1 was estimated. The results showed that there was no cyclic variation at 60 BPM. The backscattering was also plotted against the mean flow velocity, which demonstrated the hysteresis loops. The ultrasonic measurements showed that the relationship between the forward and backward paths of the loops were altered as beat rate, hematocrit, and shear rate were varied. Since the pulsatile flow was very complicated, a computational fluid dynamics package, FIDAPTM, was used to compute the shear rate based on the Power Law Model for non-Newtonian fluid viscosity. The non- Newtonian index and consistency in the model were computed from the viscosity to shear rate curves at 10% to 50% hematocrits measured by a cone-plate viscometer. For in vivo measurements, small pigs were used as models. Ultrasonic backscattering measurements were performed in the arteries and veins. The effect of stenosis was also investigated at the site below the renal branch in the artery. The results show that the cyclic variation from whole blood was mediated by the shear rate, hematocrit, beat rate, and fibrinogen concentration.

  1. Measurement and computation of hydrodynamic coupling at an air/water interface with an insoluble monolayer

    NASA Astrophysics Data System (ADS)

    Hirsa, Amir H.; Lopez, Juan M.; Miraghaie, Reza

    2001-09-01

    The coupling between a bulk vortical flow and a surfactant-influenced air/water interface has been examined in a canonical flow geometry through experiments and computations. The flow in an annular region bounded by stationary inner and outer cylinders is driven by the constant rotation of the floor and the free surface is initially covered by a uniformly distributed insoluble monolayer. When driven slowly, this geometry is referred to as the deep-channel surface viscometer and the flow is essentially azimuthal. The only interfacial property that affects the flow in this regime is the surface shear viscosity, [mu]s, which is uniform on the surface due to the vanishingly small concentration gradient. However, when operated at higher Reynolds number, secondary flow drives the surfactant film towards the inner cylinder until the Marangoni stress balances the shear stress on the bulk fluid. In general, the flow can be influenced by the surface tension, [sigma], and the surface dilatational viscosity, [kappa]s, as well as [mu]s. However, because of the small capillary number of the present flow, the effects of surface tension gradients dominate the surface viscosities in the radial stress balance, and the effect of [mu]s can only come through the azimuthal stress. Vitamin K1 was chosen for this study since it forms a well-behaved insoluble monolayer on water and [mu]s is essentially zero in the range of concentration on the surface, c, encountered. Thus the effect of Marangoni elasticity on the interfacial stress could be isolated. The flow near the interface was measured in an optical channel using digital particle image velocimetry. Steady axisymmetric flow was observed at the nominal Reynolds number of 8500. A numerical model has been developed using the axisymmetric Navier Stokes equations to examine the details of the coupling between the bulk and the interface. The nonlinear equation of state, [sigma](c), for the vitamin K1 monolayer was measured and utilized in the computations. Agreement was demonstrated between the measurements and computations, but the flow is critically dependent on the nonlinear equation of state.

  2. Modifying the mechanical properties of silk nanofiber scaffold by knitted orientation for regenerative medicine applications.

    PubMed

    Dodel, M; Hemmati Nejad, N; Bahrami, S H; Soleimani, M; Hanaee-Ahvaz, H

    2016-08-31

    Tissue reconstruction is among the increasing applications of polymer nanofibers. Fibrous scaffolds (mats) can be easily produced using the electrospinning method with structure and biomechanical properties similar to those of a cellular matrix. Electrospinning is widely used in the production of nanofibers and the GAP-method electrospinning is one of the means of producing fully aligned nanofibers. In this research, using the GAP-method, knitted fibrous scaffolds were made of silk fibroin, which is a biocompatible and biodegradable polymer. To extract fibroin from cocoons, the sodium chloride solution as well as dialysis and freeze-drying techniques were employed. The molecular weight of the extracted fibroin was measured with the SDS-Page electrophoresis technique. Moreover, the pure fibroin structure was examined using the ATR-FTIR method, and the viscosity of the solution used for electrospinning was measured with the Brookfield rotational viscometer. The scaffolds were prepared through electrospinning of the silk fibroin in pure formic acid solution. The following three structures were electrospun: 1) a random structure; 2) a knitted structure with an interstitial angle of 60 degrees; 3) a knitted structure with an interstitial angle of 90 degrees. Morphology of the resulting fibers was studied with a SEM (scanning electron microscope). Fibroin scaffolds are degradable in water. Therefore, they were fixated through immersion in methanol to be prepared for assays. The mechanical properties of the scaffolds were also studied using a tensile strength test device. The effect of methanol on the strength properties of the samples was also assessed. The hydrophilic potential of the samples was measured via a contact angle test. To increase the hydrophilicity of the scaffold surfaces, the cold oxygen plasma technique was employed. Finally, the biocompatibility and cell adhesion of the resulting scaffolds were examined through a HEK 293 cell culture, and the results were analyzed through the MTT, DAPI staining, and SEM imaging techniques. Results revealed that the oriented knitted structure contributed to the increase in Young's modulus and the maximum strength of scaffolds as compared to the random samples. Moreover, this structure can also be a suitable alternative to the typical chemical means of increasing strength.

  3. Characterization of dimethacrylate polymeric networks: a study of the crosslinked structure formed by monomers used in dental composites

    PubMed Central

    Shelton, Zachary R.; Braga, Roberto R.; Windmoller, Dario; Machado, José C.

    2011-01-01

    The resin phase of dental composites is mainly composed of combinations of dimethacrylate comonomers, with final polymeric network structure defined by monomer type/reactivity and degree of conversion. This fundamental study evaluates how increasing concentrations of the flexible triethylene glycol dimethacrylate (TEGDMA) influences void formation in bisphenol A diglycidyl dimethacrylate (BisGMA) co-polymerizations and correlates this aspect of network structure with reaction kinetic parameters and macroscopic volumetric shrinkage. Photopolymerization kinetics was followed in real-time by a near-infrared (NIR) spectroscopic technique, viscosity was assessed with a viscometer, volumetric shrinkage was followed with a linometer, free volume formation was determined by positron annihilation lifetime spectroscopy (PALS) and the sol-gel composition was determined by extraction with dichloromethane followed by 1H-NMR analysis. Results show that, as expected, volumetric shrinkage increases with TEGDMA concentration and monomer conversion. Extraction/1H-NMR studies show increasing participation of the more flexible TEGDMA towards the limiting stages of conversion/crosslinking development. As the conversion progresses, either based on longer irradiation times or greater TEGDMA concentrations, the network becomes more dense, which is evidenced by the decrease in free volume and weight loss after extraction in these situations. For the same composition (BisGMA/TEGDMA 60–40 mol%) light-cured for increasing periods of time (from 10 to 600 s), free volume decreased and volumetric shrinkage increased, in a linear relationship with conversion. However, the correlation between free volume and macroscopic volumetric shrinkage was shown to be rather complex for variable compositions exposed for the same time (600 s). The addition of TEGDMA decreases free-volume up to 40 mol% (due to increased conversion), but above that concentration, in spite of the increase in conversion/crosslinking, free volume pore size increases due to the high concentration of the more flexible monomer. In those cases, the increase in volumetric shrinkage was due to higher functional group concentration, in spite of the greater free volume. Therefore, through the application of the PALS model, this study elucidates the network formation in dimethacrylates commonly used in dental materials. PMID:21499538

  4. Characterization of dimethacrylate polymeric networks: a study of the crosslinked structure formed by monomers used in dental composites.

    PubMed

    Pfeifer, Carmem S; Shelton, Zachary R; Braga, Roberto R; Windmoller, Dario; Machado, José C; Stansbury, Jeffrey W

    2011-02-01

    The resin phase of dental composites is mainly composed of combinations of dimethacrylate comonomers, with final polymeric network structure defined by monomer type/reactivity and degree of conversion. This fundamental study evaluates how increasing concentrations of the flexible triethylene glycol dimethacrylate (TEGDMA) influences void formation in bisphenol A diglycidyl dimethacrylate (BisGMA) co-polymerizations and correlates this aspect of network structure with reaction kinetic parameters and macroscopic volumetric shrinkage. Photopolymerization kinetics was followed in real-time by a near-infrared (NIR) spectroscopic technique, viscosity was assessed with a viscometer, volumetric shrinkage was followed with a linometer, free volume formation was determined by positron annihilation lifetime spectroscopy (PALS) and the sol-gel composition was determined by extraction with dichloromethane followed by (1)H-NMR analysis. Results show that, as expected, volumetric shrinkage increases with TEGDMA concentration and monomer conversion. Extraction/(1)H-NMR studies show increasing participation of the more flexible TEGDMA towards the limiting stages of conversion/crosslinking development. As the conversion progresses, either based on longer irradiation times or greater TEGDMA concentrations, the network becomes more dense, which is evidenced by the decrease in free volume and weight loss after extraction in these situations. For the same composition (BisGMA/TEGDMA 60-40 mol%) light-cured for increasing periods of time (from 10 to 600 s), free volume decreased and volumetric shrinkage increased, in a linear relationship with conversion. However, the correlation between free volume and macroscopic volumetric shrinkage was shown to be rather complex for variable compositions exposed for the same time (600 s). The addition of TEGDMA decreases free-volume up to 40 mol% (due to increased conversion), but above that concentration, in spite of the increase in conversion/crosslinking, free volume pore size increases due to the high concentration of the more flexible monomer. In those cases, the increase in volumetric shrinkage was due to higher functional group concentration, in spite of the greater free volume. Therefore, through the application of the PALS model, this study elucidates the network formation in dimethacrylates commonly used in dental materials.

  5. Up to 50-fold increase in urine viscosity with iso-osmolar contrast media in the rat.

    PubMed

    Seeliger, Erdmann; Becker, Klaus; Ladwig, Mechthild; Wronski, Thomas; Persson, Pontus B; Flemming, Bert

    2010-08-01

    To compare changes in urinary viscosity in the renal tubules following administration of a high-viscosity iso-osmolar contrast agent (iodixanol) to that observed following administration of a less viscous, higher osmolar contrast agent (iopromide) in anesthetized rats. A total of 43 rats were studied. Experiments were approved by the Berlin, Germany, animal protection administration. A viscometer was developed to measure viscosity in minute samples (7 microL). Urine was collected, viscosity was measured (at 37 degrees C), and glomerular filtration rate (GFR) was determined by means of creatinine clearance. Boluses of 1.5 mL of iodixanol (320 mg iodine per milliliter, iso-osmolar to plasma, high viscosity) or iopromide (370 mg iodine per milliliter, higher osmolality and lower viscosity than iodixanol) were injected into the thoracic aorta. There were five groups (seven rats per group). Groups 1 (iodixanol) and 2 (iopromide) had free access to water prior to the experiment; groups 3 (iodixanol) and 4 (iopromide) received an additional infusion of isotonic saline (4 mL/kg/h). Group 5 was treated as group 1 but received only 0.75 mL of iodixanol. The observation period was 100 minutes. Statistical comparisons were made by means of nonparametric procedures (Friedman test, Kruskal-Wallis test). Iodixanol increased urine viscosity from 0.69 to 36.7 mm(2)/sec; thus, urine became threefold more viscous than native iodixanol solution. The increase in urine viscosity after injection of iopromide was from 0.73 to 2.3 mm(2)/sec. While GFR was not significantly affected by iopromide, GFR transiently decreased by 50% after administration of iodixanol. Iopromide had a diuretic effect twofold greater than that of iodixanol. Saline infusion blunted the viscosity rise and transient decline in GFR caused by iodixanol, as did reducing the iodixanol dose by 50%. Contrast media, in particular iodixanol, increase urine viscosity (which is equal to tubular fluid viscosity in the collecting ducts); in response to iodixanol, GFR markedly decreases. Saline infusion attenuates this response, thus potentially explaining the protective effects of volume expansion in contrast medium-induced nephropathy.

  6. Determination of the molecular weight of low-molecular-weight heparins by using high-pressure size exclusion chromatography on line with a triple detector array and conventional methods.

    PubMed

    Bisio, Antonella; Mantegazza, Alessandra; Vecchietti, Davide; Bensi, Donata; Coppa, Alessia; Torri, Giangiacomo; Bertini, Sabrina

    2015-03-19

    The evaluation of weight average molecular weight (Mw) and molecular weight distribution represents one of the most controversial aspects concerning the characterization of low molecular weight heparins (LMWHs). As the most commonly used method for the measurement of such parameters is high performance size exclusion chromatography (HP-SEC), the soundness of results mainly depends on the appropriate calibration of the chromatographic columns used. With the aim of meeting the requirement of proper Mw standards for LMWHs, in the present work the determination of molecular weight parameters (Mw and Mn) by HP-SEC combined with a triple detector array (TDA) was performed. The HP-SEC/TDA technique permits the evaluation of polymeric samples by exploiting the combined and simultaneous action of three on-line detectors: light scattering detectors (LALLS/RALLS); refractometer and viscometer. Three commercial LMWH samples, enoxaparin, tinzaparin and dalteparin, a γ-ray depolymerized heparin (γ-Hep) and its chromatographic fractions, and a synthetic pentasaccharide were analysed by HP-SEC/TDA. The same samples were analysed also with a conventional HP-SEC method employing refractive index (RI) and UV detectors and two different chromatographic column set, silica gel and polymeric gel columns. In both chromatographic systems, two different calibration curves were built up by using (i) γ-Hep chromatographic fractions and the corresponding Mw parameters obtained via HP-SEC/TDA; (ii) the whole γ-Hep preparation with broad Mw dispersion and the corresponding cumulative distribution function calculated via HP-SEC/TDA. In addition, also a chromatographic column calibration according to European Pharmacopoeia indication was built up. By comparing all the obtained results, some important differences among Mw and size distribution values of the three LMWHs were found with the five different calibration methods and with HP-SEC/TDA method. In particular, the detection of the lower molecular weight components turned out to be the most critical aspect. Whereas HP-SEC/TDA may underestimate species under 2 KDa when present in low concentration, other methods appeared to emphasize their content.

  7. Crystal-rich lava dome extrusion during vesiculation: An experimental study

    NASA Astrophysics Data System (ADS)

    Pistone, Mattia; Whittington, Alan G.; Andrews, Benjamin J.; Cottrell, Elizabeth

    2017-11-01

    Lava dome-forming eruptions represent a common eruptive style and a major hazard at numerous active volcanoes worldwide. The extrusion mechanics of crystal-rich lava domes and the influence of volatiles on the transition from viscous to brittle behaviour during lava dome extrusion remain unclear. Understanding how gas exsolution and crystallinity control effusive versus explosive eruption behaviour is essential. Here, we present new experimental results on the rheology of synthesised, crystal-rich (50 to 80 vol% quartz crystals), hydrous (4.2 wt% H2O in the glass) dacite samples, which vesiculate from 5 to 27 vol% gas bubbles at high temperatures (from glass transition temperature to 797 °C) during deformation conducted in a parallel plate viscometer (constant stress at 0.63-0.64 MPa, and variable strain-rates ranging from 8.32·10- 8 to 3.58·10- 5 s- 1). The experiments reproduce certain aspects of lava dome deformation in volcanic conduits during vesiculation of the residual melt, instigated in the experiments by increasing temperature. During gas exsolution (i.e. nucleation and growth of gas-pressurised bubbles) and volume inflation, we find that the rheological lubrication of the system during deformation is strongly dictated by the initial crystallinity. At crystal contents < 60 vol%, gas bubbles form and coalesce during expansion and viscous deformation, favouring strain localisation and gas permeability within shear bands, which control the overall sample rheology. At crystallinities of 60 to 70 vol%, gas exsolution generates pressurisation (i.e. pore pressure increase) within the bubbles trapped in the solid crystal clusters, and embryonic formation of microscopic fractures through melt and crystals drives the system to a brittle behaviour. At higher crystallinity (80 vol%) vesiculation leads to large pressurisation, which then triggers extensive brittle fragmentation. Through macroscopic fractures, outgassing determines the rheological stalling of the system. In the light of these results we propose a rheological description of crystal-rich lava dome mechanics. The contrasting experimental behaviours at different crystallinities have implications for the style of slow-ascending dome-forming eruptions. All other factors being equal, our experiments suggest that crystal-poor magmas will undergo efficient outgassing, reducing the potential for an explosive eruption. Conversely, crystal-rich magmas may experience limited outgassing and larger gas overpressures during vesiculation, therefore increasing the potential for an explosive eruption.

  8. Measurements and properties of ice particles and carbon dioxide bubbles in aqueous mixture utilizing optical techniques

    NASA Astrophysics Data System (ADS)

    Diallo, Amadou O.

    Optical techniques are used to determine the size, shape and many other properties of particles ranging from the micro to a nano-level. These techniques have endless applications. This research is based on a project assigned by a "Vendor" that wants anonymity. The Leica optical microscope and the Dark Field Polarizing Metallurgical Microscope is used to determine the size and count of ice crystals (Vendors products) in multiple time frames. Since the ice temperature influences, its symmetry and the shape is subject to changes at room temperature (300 K) and the atmospheric pressure that is exerted on the ice crystals varies. The ice crystals are in a mixture of water, electrolytes and carbon dioxide with the optical spectroscopy (Qpod2) and Spectra suite, the optical density of the ice crystals is established from the absorbance and transmission measurements. The optical density in this case is also referred to as absorption; it is plotted with respect to a frequency (GHz), wavelength (nm) or Raman shift (1/cm) which shows the light colliding with the ice particles and CO2. Depending on the peaks positions, it is possible to profile the ice crystal sizes using a mean distribution plots. The region of absorbency wavelength expected for the ice is in the visible range; the water molecules in the (UV) Ultra-violet range and the CO2 in the (IR) infrared region. It is also possible to obtain the reflection and transmission output as a percentage change with the wavelengths ranging from 200 to 1100 nm. The refractive index of the ice can be correlated to the density based on the optical acoustic theorem, or Mie Scattering Theory. The viscosity of the ice crystals and the solutions from which the ice crystals are made of as well are recorded with the SV-10 viscometer. The baseline viscosity is used as reference and set lower than that of the ice crystals. The Zeta potential of the particles present in the mixture are approximated by first finding the viscosity of the solution where the pH level contribute to the surface charges, afterward use Stoke's diameter to compute the settling velocity of the bubbles, or alternatively record it under the microscope. With those parameters in hand the surface charge of the bubble (zeta potential) is approximated.

  9. Transition of basaltic lava from pahoehoe to aa, Kilauea Volcano, Hawaii: Field observations and key factors

    USGS Publications Warehouse

    Peterson, Donald W.; Tilling, Robert I.

    1980-01-01

    Nearly all Hawaiian basaltic lava erupts as pahoehoe, and some changes to aa during flowage and cooling; factors governing the transition involve certain critical relations between viscosity and rate of shear strain. If the lava slows, cools, and stops in direct response to concomitant increase in viscosity before these critical relations are reached, it remains pahoehoe. But, if flow mechanics (flow rate, flow dimensions, slope, momentum, etc.) impel the lava to continue to move and deform even after it has become highly viscous, the critical relations may be reached and the lava changes to aa.Typical modes of transition from pahoehoe to aa include: (1) spontaneous formation of relatively stiff clots in parts of the flowing lava where shear rate is highest; these clots grow into discrete, rough, sticky masses to which the remaining fluid lava incrementally adheres; (2) fragmentation and immersion of solid or semi-solid surface crusts of pahoehoe by roiling movements of the flow, forming cores of discrete, tacky masses; (3) sudden renewed movement of lava stored and cooled within surface reservoirs to form clots. The masses, fragments, and clots in these transition modes are characterized by spinose, granulated surfaces; as flow movement continues, the masses and fragments aggregate, fracture, and grind together, completing the transition to aa.Observations show that the critical relation between viscosity and rate of shear strain is inverse: if viscosity is low, a high rate of shear is required to begin the transition to aa; conversely, if viscosity is high, a much lower rate of shear will induce the transition. These relations can be demonstrated qualitatively with simple graphs, which can be used to examine the flow history of any selected finite lava element by tracing the path represented by its changing viscosity and shear rate. A broad, diffuse “transition threshold zone” in these graphs portrays the inverse critical relation between viscosity and shear rate; the transition to aa is represented by the path of the lava element crossing this zone.Moving lava flows can be regarded as natural viscometers, by which shear stress and rate of shear strain at selected points can be determined and viscosity can be computed. By making such determinations under a wide range of conditions on pahoehoe, aa, and transitional flow types, the critical relations that control the pahoehoe-aa transition can be quantified.

  10. Laboratory experiments on fragmentation of highly-viscous bubbly syrup

    NASA Astrophysics Data System (ADS)

    Kurihara, H.; Kameda, M.; Ichihara, M.

    2006-12-01

    Fragmentation of vesicular magma by rapid decompression is a key process in explosive eruptions. To determine the fragmentation criteria, we carried out laboratory experiments on magma fragmentation using analogous materials. We used commercial syrup as an analogous material of magma, because the viscosity was widely altered by adding or subtracting water contents in the syrup. We made the bubbly syrup by adding hydrogen peroxide with manganese oxide in the syrup. The amount of hydrogen peroxide is proportional to the gas volume fraction in the syrup. We measured the rheological properties of the syrup. Zero shear viscosity η was measured by a rotating viscometer and a fiber elongation technique. Glass transition temperature was measured by differential scanning calorimetry. The measured data indicated that the temperature dependence of viscosity was described well using Williams-Landel-Ferry (WLF) equation. The solid content of syrup alters the viscosity as well as the glass transition temperature, though it may hardly affect the rigidity μ, which was measured by ultrasonic test in our previous work. We used a pressurized vertical tube with a large vacuum vessel to apply the rapid decompression on the material. An acrylic container, filled with the bubbly syrup, was placed in the bottom of the pressurized tube. By rupturing the diaphragms inserted between the tube and the vacuum vessel, the bubbly syrup is rapidly decompressed due to expansion of the pressurized gas in the tube. A high-speed video camera was used to obtain sequential images of the materials. Pressure transducers were mounted on the sidewall of the tube and the bottom of the container. The initial pressure was varied from 1 MPa to 5 MPa. The gas-volume fraction of the syrup under pressure was fixed as 2 % to 20%. The viscosity varied from 105 Pa·s to 108 Pa·s. We successfully observed three principal behaviors using the present analogous material; brittle fragmentation, partial fracture and ductile expansion without crack initiation. From all the experimental data, in conclusion, the fragmentation is observed when the pressure drop Δ p reaches a critical value within the order of relaxation time of syrup, which is defined as η/μ. Simultaneously, the initial gas volume fraction should be larger than a critical value, which decreases as the initial high-pressure is larger.

  11. Shear thinning behaviors in magmas

    NASA Astrophysics Data System (ADS)

    Vetere, F. P.; Cassetta, M.; Perugini, D.

    2017-12-01

    Studies on magma rheology are of fundamental importance to understanding magmatic processes from depth to surface. Since viscosity is one of the most important parameter controlling eruption mechanisms, as well as lava flow emplacement, a comprehensive knowledge on the evolution of magma viscosities during crystallization is required. We present new viscosity data on partly crystalized basalt, andesite and analogue lavas comparable to those erupted on Mercury's northern volcanic plains. High-temperature viscosity measurements were performed using a rotational Anton Paar RheolabQC viscometer head at the PVRG labs, in Perugia (Italy) (http://pvrg.unipg.it). The relative proportion of phases in each experimental run were determined by image analysis on BS-SEM images at different magnifications; phases are glasses, clinopyroxene, spinel, plagioclase for the basalt, plagioclase and spinel for the andesite and pure enstatite and clinopyroxenes, for the analogue Mercury's composition. Glass and crystalline fractions determined by image analysis well correlate with compositions of residual melts. In order to constrain the viscosity (η) variations as a function of crystallinity, shear rate (γ) was varied from 0.1 to 5 s-1. Viscosity vs. time at constant temperature shows a typical S-shape curve. In particular, for basaltic composition η vary from 3.1-3.8 Pa s [log η] at 1493 K and crystallinity of 19 area % as γ vary from 1.0 to 0.1 s-1; the andesite viscosity evolution is 3.2 and 3.7 Pa s [log η] as γ varies from 1 to 0.1 at 1493 K and crystal content of 17 area %; finally, Mercury's analogue composition was investigated at different temperature ranging from 1533 to 1502 K (Vetere et al., 2017). Results, for γ = 0.1, 1.0 and 5.0 s-1, show viscosity variation between 2.7-4.0, 2.5-3.4 and 2.0-3.0 [log η inPa s] respectively while crystallinity vary from 9 to 27 (area %). As viscosity decreases as shear rate increases, these data points to a shear thinning behaviour of the partly crystallized melt. This new dataset can be used to model the behaviour of lavas during magma rise in conduits and lava flow on Earth surface and other planetary bodies. F. Vetere et al., (2017) Experimental constraints on the rheology, eruption and emplacement dynamics of lavas from Mercury Northern Volcanic Plains". JGR-Planets DOI: 10.1002/2016JE005181

  12. INSTRUMENTATION AND CONTROLS DIVISION ANNUAL PROGRESS REPORT FOR PERIOD ENDING JULY 1, 1957

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1958-10-31

    The circuitry and performance characteristics are given for a pulse crossover pickoff gate for use with a medium-speed coincidence circuit. An experimental digital count-rate meter was built which has the analog output characteristics of a rate meter and the counting mechanism of a scaler. A study was made of the grid currents in comnmercially available receiving and amplifying tubes. The study was limited to grid currents exceeding 10 amp, plats voltages between 20 and 300 v, and cathode currents between 50 mu a and 100 ma Tests were conducted to determine the intrinsic staility of neon-filled voltage reference tubes. Internalmore » impedance and drift rate are given for a number of tube types. A neutron-chopper speed-control systemn for use with the time-of-flight spectrometer is being developed. A block diagram of the system is given. The main features of a 256-channel neutron time-of-flight spectrometer Instrumentation for the ORNL Graphite Reactor pile oscillator was redesigned for greater spend and accuracy. A block diagram is given along with preliminary the performance characteristics are given for an 18channel time-base analyzer developed to study the timedependent behavior of neutrons in a moderator. Progress in the developmnent of a position indicator for the single-crystal spectrometer being installed in the Bulk Shielding Facility is reviewed. Modifications made in an existing electron-spin resonance spectromneter to convert it to a superheterodyne electron-spin resonance tem superior in versatility, reliability, and speed, was installed at the ORAC LE. Developmental work on a small, high-efficiency scintillation Geiger counter is described. Three variations of the standard method for preparing zinc sulfide phosphors are discussed. The design and operation of a scanning device developed for scanning activated materials fromn flux distribution experiments is described. Additional work is reported on the development of instrumentation for radiochemical laboratories, powder mnetallurgy laboratories, the Thorex Process, a volatility separation process, uranyl sulfate fuel processing, and homnogeneous reactor control. Specific pieces of equipment developed and described include a resin- bed displacement meter, a viscometer, liquid-level indicators, pressure transmitters, a flow transmitter, a gamma ionization chamber, an oxygen injection system, valves and valve actuators, a magetic flowmeter, and thermocouples. or preceding period see ORNL-2234.) (U.E.B.)« less

  13. Shear Thinning Near the Critical Point of Xenon

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory A.; Berg, Robert F.; Moldover, Michael R.; Yao, Minwu

    2008-01-01

    We measured shear thinning, a viscosity decrease ordinarily associated with complex liquids, near the critical point of xenon. The data span a wide range of reduced shear rate: 10(exp -3) < gamma-dot tau < 700, where gamma-dot tau is the shear rate scaled by the relaxation time tau of critical fluctuations. The measurements had a temperature resolution of 0.01 mK and were conducted in microgravity aboard the Space Shuttle Columbia to avoid the density stratification caused by Earth's gravity. The viscometer measured the drag on a delicate nickel screen as it oscillated in the xenon at amplitudes 3 mu,m < chi (sub 0) >430 mu, and frequencies 1 Hz < omega/2 pi < 5 Hz. To separate shear thinning from other nonlinearities, we computed the ratio of the viscous force on the screen at gamma-dot tau to the force at gamma-dot tau approximates 0: C(sub gamma) is identical with F(chi(sub 0), omega tau, gamma-dot tau )/F)(chi(sub 0, omega tau, 0). At low frequencies, (omega tau)(exp 2) < gamma-dot tau, C(sub gamma) depends only on gamma-dot tau, as predicted by dynamic critical scaling. At high frequencies, (omega tau)(exp 2) > gamma-dot tau, C(sub gamma) depends also on both x(sub 0) and omega. The data were compared with numerical calculations based on the Carreau-Yasuda relation for complex fluids: eta(gamma-dot)/eta(0)=[1+A(sub gamma)|gamma-dot tau|](exp - chi(sub eta)/3+chi(sub eta)), where chi(sub eta) =0.069 is the critical exponent for viscosity and mode-coupling theory predicts A(sub gamma) =0.121. For xenon we find A(sub gamma) =0.137 +/- 0.029, in agreement with the mode coupling value. Remarkably, the xenon data close to the critical temperature T(sub c) were independent of the cooling rate (both above and below T(sub c) and these data were symmetric about T(sub c) to within a temperature scale factor. The scale factors for the magnitude of the oscillator s response differed from those for the oscillator's phase; this suggests that the surface tension of the two-phase domains affected the drag on the screen below T(sub c).

  14. Viscosity of carbonate-rich melts under different oxygen fugacity conditions

    NASA Astrophysics Data System (ADS)

    Di Genova, Danilo; Hess, Kai-Uwe; Cimarelli, Corrado; Dingwell, Donald B.

    2015-04-01

    Viscosity is a fundamental property of many materials and its changes affects the fluid dynamics of natural system as well as industrial processes. The mobility of carbonatitic melts, which are carbonate-rich and very fluid melts, has attracted renewed interest in both earth science and industry. In fact, these melts are considered the main transport agent of carbon from the mantle to the crust and may be intimately linked to the generation of kimberlites. At the same time lithium, potassium and sodium carbonate are used as electrolytes in molten carbonate fuel cells which operate at high temperatures (~650° C) for the production of electricity without CO2 emissions. Accurate measurement of the transport property (i.e. viscosity) of carbonatitic melts is a priority in order to understand the carbonatite mobility and reaction rates. Additionally, obtaining accurate viscosity measurements of such low viscosity melts is however an experimental challenge due to volatility, very low torques and chemical melt instability in the viscometer. To overcome these limitations we have customized a Modular Compact Rheometer (MCR 502 from Anton Paar) ad hoc equipped with 2 narrow gap concentric-cylinder geometries of steel and Pt-Au. The rheometer is characterized by an air-bearing-supported synchronous motor with torque ranging between 0.01 μNm and 230 mNm (resolution of 0.1 nNm), achieving very low viscosity measurements in the order of mPa s, temperatures up to 1000° C and shear rates ranging between 1 and 100 sec-1. These experimental conditions well match the temperature-viscosity-shear rate window relevant for carbonate melts. Here we present the calibration of the rheometer and the results of a rheological characterization study on a series of very low viscous synthetic and natural carbonatitic melts at different oxygen fugacity (air and CO2 saturated atmosphere). Viscosity measurements on carbonate melts have been performed in the temperature range between ~650 and 1000° C. Measured values range between ~2 and 20 mPa sec. The results point out that the viscosity of synthetic samples is inversely related to the cations radius, being Li2CO3 melt the more viscous. Viscosity measurements on natural samples (carbonatitic lava from Lengai volcano, Tanzania), reveal a higher viscosity (~1000 mPa s) and a dramatic higher activation energy than the synthetic samples. Our results have been compared with literature data in order to determine the effect of chemical composition and oxygen fugacity conditions on the liquid viscosity of carbonatitic melts.

  15. Endothelial Microparticles From Acute Coronary Syndrome Patients Induce Premature Coronary Artery Endothelial Cell Aging and Thrombogenicity: Role of the Ang II/AT1 Receptor/NADPH Oxidase-Mediated Activation of MAPKs and PI3-Kinase Pathways.

    PubMed

    Abbas, Malak; Jesel, Laurence; Auger, Cyril; Amoura, Lamia; Messas, Nathan; Manin, Guillaume; Rumig, Cordula; León-González, Antonio J; Ribeiro, Thais P; Silva, Grazielle C; Abou-Merhi, Raghida; Hamade, Eva; Hecker, Markus; Georg, Yannick; Chakfe, Nabil; Ohlmann, Patrick; Schini-Kerth, Valérie B; Toti, Florence; Morel, Olivier

    2017-01-17

    Microparticles (MPs) have emerged as a surrogate marker of endothelial dysfunction and cardiovascular risk. This study examined the potential of MPs from senescent endothelial cells (ECs) or from patients with acute coronary syndrome (ACS) to promote premature EC aging and thrombogenicity. Primary porcine coronary ECs were isolated from the left circumflex coronary artery. MPs were prepared from ECs and venous blood from patients with ACS (n=30) and from healthy volunteers (n=4) by sequential centrifugation. The level of endothelial senescence was assessed as senescence-associated β-galactosidase activity using flow cytometry, oxidative stress using the redox-sensitive probe dihydroethidium, tissue factor activity using an enzymatic Tenase assay, the level of target protein expression by Western blot analysis, platelet aggregation using an aggregometer, and shear stress using a cone-and-plate viscometer. Senescence, as assessed by senescence-associated β-galactosidase activity, was induced by the passaging of porcine coronary artery ECs from passage P1 to P4, and was associated with a progressive shedding of procoagulant MPs. Exposure of P1 ECs to MPs shed from senescent P3 cells or circulating MPs from ACS patients induced increased senescence-associated β-galactosidase activity, oxidative stress, early phosphorylation of mitogen-activated protein kinases and Akt, and upregulation of p53, p21, and p16. Ex vivo, the prosenescent effect of circulating MPs from ACS patients was evidenced only under conditions of low shear stress. Depletion of endothelial-derived MPs from ACS patients reduced the induction of senescence. Prosenescent MPs promoted EC thrombogenicity through tissue factor upregulation, shedding of procoagulant MPs, endothelial nitric oxide synthase downregulation, and reduced nitric oxide-mediated inhibition of platelet aggregation. These MPs exhibited angiotensin-converting enzyme activity and upregulated AT1 receptors and angiotensin-converting enzyme in P1 ECs. Losartan, an AT1 receptor antagonist, and inhibitors of either mitogen-activated protein kinases or phosphoinositide 3-kinase prevented the MP-induced endothelial senescence. These findings indicate that endothelial-derived MPs from ACS patients induce premature endothelial senescence under atheroprone low shear stress and thrombogenicity through angiotensin II-induced redox-sensitive activation of mitogen-activated protein kinases and phosphoinositide 3-kinase/Akt. They further suggest that targeting endothelial-derived MP shedding and their bioactivity may be a promising therapeutic strategy to limit the development of an endothelial dysfunction post-ACS. © 2016 American Heart Association, Inc.

  16. Development and Implementation of Non-Newtonian Rheology Into the Generalized Fluid System Simulation Program (GFSSP)

    NASA Technical Reports Server (NTRS)

    DiSalvo, Roberto; Deaconu, Stelu; Majumdar, Alok

    2006-01-01

    One of the goals of this program was to develop the experimental and analytical/computational tools required to predict the flow of non-Newtonian fluids through the various system components of a propulsion system: pipes, valves, pumps etc. To achieve this goal we selected to augment the capabilities of NASA's Generalized Fluid System Simulation Program (GFSSP) software. GFSSP is a general-purpose computer program designed to calculate steady state and transient pressure and flow distributions in a complex fluid network. While the current version of the GFSSP code is able to handle various systems components the implicit assumption in the code is that the fluids in the system are Newtonian. To extend the capability of the code to non-Newtonian fluids, such as silica gelled fuels and oxidizers, modifications to the momentum equations of the code have been performed. We have successfully implemented in GFSSP flow equations for fluids with power law behavior. The implementation of the power law fluid behavior into the GFSSP code depends on knowledge of the two fluid coefficients, n and K. The determination of these parameters for the silica gels used in this program was performed experimentally. The n and K parameters for silica water gels were determined experimentally at CFDRC's Special Projects Laboratory, with a constant shear rate capillary viscometer. Batches of 8:1 (by weight) water-silica gel were mixed using CFDRC s 10-gallon gelled propellant mixer. Prior to testing the gel was allowed to rest in the rheometer tank for at least twelve hours to ensure that the delicate structure of the gel had sufficient time to reform. During the tests silica gel was pressure fed and discharged through stainless steel pipes ranging from 1", to 36", in length and three diameters; 0.0237", 0.032", and 0.047". The data collected in these tests included pressure at tube entrance and volumetric flowrate. From these data the uncorrected shear rate, shear stress, residence time, and viscosity were evaluated using formulae for non-Newtonian, power law fluids. The maximum shear rates (corrected for entrance effects) obtained in the rheometer with the current setup were in the 150,000 to 170,000sec- range. GFSSP simulations were performed with a flow circuit simulating the capillary rheometer and using Power Law gel viscosity coefficients from the experimental data. The agreement between the experimental data and the simulated flow curves was within +/-4% given quality entrance effect data.

  17. Oxidation-state dependence of rheology in peralkaline glasses of phonolitic composition

    NASA Astrophysics Data System (ADS)

    Scherrer, M. C.; Hess, K.-U.; Fehr, K. T.; Dingwell, D. B.

    2012-04-01

    The precise description of magmatic melts rheology at the glass transition is crucial in understanding dynamic processes in volcanology. The glass transition has been described to scale with the viscosity of the material according to Maxwell's relaxation theory for viscoelastic liquids (Dingwell and Webb, 1989). The temperature dependence of the viscosity of multi-component systems can adequately be calculated using empirical models such as Hess et al. (1996), Giordano et al. (2008) and Hui and Zhang (2008); yet, within these calculations, the influence of oxidation state has been so far considered minor and was consequently neglected. The rheological behavior of some iron-rich silicate melts has shown noteworthy oxidation state-dependent variations (Cukierman and Uhlmann 1974, Dingwell and Virgo 1987). The focus of our study is to improve the viscosity models by investigating the necessity of an additional redox-parameter. Thirteen re-melted glass samples of natural phonolitic composition (peralkaline lavas with 8.5 wt. % FeOtot) were produced under different oxygen fugacity (fO2) conditions in a CO/CO2 gas-mixing furnace. Their oxidation-state (Fe3+/Fetot) ranges from 0.44 to 0.93 (±0.05). The viscosity above the liquidus was recorded via the concentric cylinder technique at a constant temperature of 1186 ° C. Additionally, viscosities were measured in the interval of 107to 1011Pa swith temperatures up to 900 ° C at ambient pressure via a BAEHR micro-penetration viscometer. Glass transition temperatures (Tg) have been determined with a constant heating/cooling rate of 10K/min on a SETARAM Sensys evo DSC using the peak of the specific heat capacity curve. Under a constant temperature in the super-liquidus state, the viscosity increases strongly with increasing fO2. In the sub-liquidus state, the measured calorimetric Tgis shifted to lower temperatures as the ratio of ferrous/total iron decreases from 638 ° C to 610 ° C. However, there is no equivalent measurable effect of the oxidation-state on super-cooled melt viscosity at Tg, within the precision of the micro-penetration experiment (all values are scattered around 10.10 ± 0.2 Pa s). Our results show a large discrepancy of 0.5 log units compared to the predicted viscosity at Tg using the kinetic model of Gottsmann et al. (2002). We further investigate additional relatively iron-rich compositions aiming for the development of an improved model for the viscosity prediction at the glass transition.

  18. NVP melt/magma viscosity: insight on Mercury lava flows

    NASA Astrophysics Data System (ADS)

    Rossi, Stefano; Morgavi, Daniele; Namur, Olivier; Vetere, Francesco; Perugini, Diego; Mancinelli, Paolo; Pauselli, Cristina

    2016-04-01

    After more than four years of orbiting Mercury, NASA's MESSENGER spacecraft came to an end in late April 2015. MESSENGER has provided many new and surprising results. This session will again highlight the latest results on Mercury based on MESSENGER observations or updated modelling. The session will further address instrument calibration and science performance both retrospective on MESSENGER and on the ESA/JAXA BepiColombo mission. Papers covering additional themes related to Mercury are also welcomed. Please be aware that this session will be held as a PICO session. This will allow an intensive exchange of expertise and experience between the individual instruments and mission. NVP melt/magma viscosity: insight on Mercury lava flows S. Rossi1, D. Morgavi1, O. Namur2, D. Perugini1, F.Vetere1, P. Mancinelli1 and C. Pauselli1 1 Dipartimento di Fisica e Geologia, Università di Perugia, piazza Università 1, 06123 Perugia, Italy 2 Uni Hannover Institut für Mineralogie, Leibniz Universität Hannover, Callinstraβe 3, 30167 Hannover, Germany In this contribution we report new measurements of viscosity of synthetic komatitic melts, used the behaviour of silicate melts erupted at the surface of Mercury. Composition of Mercurian surface magmas was calculated using the most recent maps produced from MESSENGER XRS data (Weider et al., 2015). We focused on the northern hemisphere (Northern Volcanic Province, NVP, the largest lava flow on Mercury and possibly in the Solar System) for which the spatial resolution of MESSENGER measurements is high and individual maps of Mg/Si, Ca/Si, Al/Si and S/Si were combined. The experimental starting material contains high Na2O content (≈7 wt.%) that strongly influences viscosity. High temperature viscosity measurements were carried out at 1 atm using a concentric cylinder apparatus equipped with an Anton Paar RheolabQC viscometer head at the Department of Physics and Geology (PVRG_lab) at the University of Perugia (Perugia, Italy). The change of melt viscosity induced by crystallization of a NVP composition was measured in the temperature ranges from 1463 to 1229 °C. Results showed an increase in effective viscosity from 4.3 Pa s to 1090 Pa s as the crystal content increased from 0 vol% to ca. 25 vol.%. The crystallization processes in the nominally dry NVP began at 1308 °C. Interestingly, melts viscosity changes from 4 to 16 Pa s as temperature varies from 1463 to 1327 °C. The extreme Mercurian lava fluidity experimentally measured has revealed the potentiality of NVP lavas to cover huge areas as shown by satellite data. Keywords: Viscosity, Concentric cylinders, NVP, Mercury.

  19. ADVANCED CUTTINGS TRANSPORT STUDY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefan Miska; Troy Reed; Ergun Kuru

    2004-09-30

    The Advanced Cuttings Transport Study (ACTS) was a 5-year JIP project undertaken at the University of Tulsa (TU). The project was sponsored by the U.S. Department of Energy (DOE) and JIP member companies. The objectives of the project were: (1) to develop and construct a new research facility that would allow three-phase (gas, liquid and cuttings) flow experiments under ambient and EPET (elevated pressure and temperature) conditions, and at different angle of inclinations and drill pipe rotation speeds; (2) to conduct experiments and develop a data base for the industry and academia; and (3) to develop mechanistic models for optimizationmore » of drilling hydraulics and cuttings transport. This project consisted of research studies, flow loop construction and instrumentation development. Following a one-year period for basic flow loop construction, a proposal was submitted by TU to the DOE for a five-year project that was organized in such a manner as to provide a logical progression of research experiments as well as additions to the basic flow loop. The flow loop additions and improvements included: (1) elevated temperature capability; (2) two-phase (gas and liquid, foam etc.) capability; (3) cuttings injection and removal system; (4) drill pipe rotation system; and (5) drilling section elevation system. In parallel with the flow loop construction, hydraulics and cuttings transport studies were preformed using drilling foams and aerated muds. In addition, hydraulics and rheology of synthetic drilling fluids were investigated. The studies were performed under ambient and EPET conditions. The effects of temperature and pressure on the hydraulics and cuttings transport were investigated. Mechanistic models were developed to predict frictional pressure loss and cuttings transport in horizontal and near-horizontal configurations. Model predictions were compared with the measured data. Predominantly, model predictions show satisfactory agreements with the measured data. As a part of this project, instrumentation was developed to monitor cuttings beds and characterize foams in the flow loop. An ultrasonic-based monitoring system was developed to measure cuttings bed thickness in the flow loop. Data acquisition software controls the system and processes the data. Two foam generating devices were designed and developed to produce foams with specified quality and texture. The devices are equipped with a bubble recognition system and an in-line viscometer to measure bubble size distribution and foam rheology, respectively. The 5-year project is completed. Future research activities will be under the umbrella of Tulsa University Drilling Research Projects. Currently the flow loop is being used for testing cuttings transport capacity of aqueous and polymer-based foams under elevated pressure and temperature conditions. Subsequently, the effect of viscous sweeps on cuttings transport under elevated pressure and temperature conditions will be investigated using the flow loop. Other projects will follow now that the ''steady state'' phase of the project has been achieved.« less

  20. Silica Fume Functionalized With Amine-Based Additives as a Modifier to Enhance Asphalt Resistance to Oxidation

    NASA Astrophysics Data System (ADS)

    Abutalib, Nader Turki

    This dissertation investigates the practical feasibility of functionalizing silica fume particles with the amine groups in Bio-binder and pure APTES chemical to disperse silica fume in asphalt binder matrix to produce silica-fume-modified binder (SFMB). Dispersed silica fume was then introduced to asphalt to reduce oxidative aging. It has been widely reported that asphalt binder oxidation is one of the phenomena that reduces the service life of asphalt pavement by negatively affecting its rheological properties. This in turn can lead to a more brittle pavement, which is more prone to cracks due to thermal stress and traffic loading. It has been shown that the introduction of 4% silica fume to asphalt can reduce asphalt oxidative aging. However, the challenge with a higher percentage of silica fume was found to be the agglomeration of nano- particles to form micro-size clusters, which can reduce the effectiveness of silica fume while making asphalt binder more susceptible to shear. Therefore, this dissertation studies the effectiveness of functionalizing the SFMB to reduce asphalt oxidative aging while alleviating the agglomeration effect. To do so, various percentages of bio-binder (BB) and bio-char (BC) were introduced to SFMB, and the rheological properties and high-temperature performance of each specimen were evaluated by measuring the rotational viscosity and complex shear modulus before and after oxidative aging. It is hypothesized that fine-graded BC and BB with nano- to micro-level particles can be used to reduce asphalt oxidation and create a new generation of low- agglomeration SFMB with higher resistance to oxidative aging. To further study the effects of functionalization on dispersion of silica fume, silica fume particles were produced with different functional groups: amine (APTES) groups and phosphonate (THPMP) groups. Agglomeration studies using a scanning electron microscope and zeta potential analysis indicate that modifying asphalt binder with amine-modified silica fume particles can reduce the agglomeration of the silica fume particles. The performance characteristics of functionalized silica fume particles and non-functionalized silica fume particles are compared with those of base asphalt. The following research hypotheses were investigated: 1) Functionalized and well-dispersed silica fume will enhance asphalt's aging resistance. 2) The amine groups in functionalizing agent interact with silica fume particles and promote their dispersion. To test these hypotheses, a rotational viscometer was used to study the effect of functionalized-silica-fume-modified binder on the high-temperature properties of the asphalt binder. Fourier transform infrared spectroscopy analysis was used to determine the chemical compounds of the amine-group silica-fume- modified binder matrix. Scanning electron microscopy was used to observe the surface morphology and analyze the microstructure characteristics of materials. The positive effect of amine groups on the rheological properties of SFMB could be attributed to the high surface area of the silica fume and its granular particles with high polarity, factors that could improve the blending properties of the bio-modified silica fume and result in a uniformly distributed silica- fume-modified matrix with enhanced oxidative aging resistance. Surface adsorption of amines on silica fume particles helps promote repulsive forces between them to enhance dispersion.

  1. ADVANCED CUTTINGS TRANSPORT STUDY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefan Miska; Nicholas Takach; Kaveh Ashenayi

    2004-01-31

    Final design of the mast was completed (Task 5). The mast is consisting of two welded plate girders, set next to each other, and spaced 14-inches apart. Fabrication of the boom will be completed in two parts solely for ease of transportation. The end pivot connection will be made through a single 2-inch diameter x 4 feet-8 inch long 316 SS bar. During installation, hard piping make-ups using Chiksan joints will connect the annular section and 4-inch return line to allow full movement of the mast from horizontal to vertical. Additionally, flexible hoses and piping will be installed to isolatemore » both towers from piping loads and allow recycling operations respectively. Calibration of the prototype Foam Generator Cell has been completed and experiments are now being conducted. We were able to generate up to 95% quality foam. Work is currently underway to attach the Thermo-Haake RS300 viscometer and install a view port with a microscope to measure foam bubble size and bubble size distribution. Foam rheology tests (Task 13) were carried out to evaluate the rheological properties of the proposed foam formulation. After successful completion of the first foam test, two sets of rheological tests were conducted at different foam flow rates while keeping other parameters constant (100 psig, 70F, 80% quality). The results from these tests are generally in agreement with the previous foam tests done previously during Task 9. However, an unanticipated observation during these tests was that in both cases, the frictional pressure drop in 2 inch pipe was lower than that in the 3 inch and 4 inch pipes. We also conducted the first foam cuttings transport test during this quarter. Experiments on aerated fluids without cuttings have been completed in ACTF (Task 10). Gas and liquid were injected at different flow rates. Two different sets of experiments were carried out, where the only difference was the temperature. Another set of tests was performed, which covered a wide range of pressure and temperature. Several parameters were measured during these tests including differential pressure and mixture density in the annulus. Flow patterns during the aerated fluids test have been observed through the view port in the annulus and recorded by a video camera. Most of the flow patterns were slug flow. Further increase in gas flow rate changed the wavy flow pattern to slug flow. At this stage, all of the planned cuttings transport tests have been completed. The results clearly show that temperature significantly affects the cuttings transport efficiency of aerated muds, in addition to the liquid flow rate and gas liquid ratio (GLR). Since the printed circuit board is functioning (Task 11) with acceptable noise level we were able to conduct several tests. We used the newly designed pipe test section to conduct tests. We tested to verify that we can distinguish between different depths of sand in a static bed of sand in the pipe section. The results indicated that we can distinguish between different sand levels. We tested with water, air and a mix of the two mediums. Major modifications (installation of magnetic flow meter, pipe fittings and pipelines) to the dynamic bubble characterization facility (DTF, Task 12) were completed. An Excel program that allows obtaining the desired foam quality in DTF was developed. The program predicts the foam quality by recording the time it takes to pressurize the loop with nitrogen.« less

  2. The role of ascitic fluid viscosity in the differential diagnosis of ascites

    PubMed Central

    Gokturk, Huseyin Savas; Demir, Mehmet; Ozturk, Nevin Akcaer; Unler, Gulhan Kanat; Kulaksizoglu, Sevsen; Kozanoglu, Ilknur; Serin, Ender; Yilmaz, Ugur

    2010-01-01

    BACKGROUND: Ascites is defined as the pathological accumulation of fluid in the peritoneal cavity. It is the most common complication of cirrhosis, which is also the most common cause of ascites. Viscosity is a measure of the resistance of a fluid to deform under shear stress. Plasma viscosity is influenced by the concentration of plasma proteins and lipoproteins, with the major contribution from fibrinogen. To our knowledge, the viscosity of ascitic fluid has not yet been studied. OBJECTIVE: To evaluate the role of ascitic fluid viscosity in discriminating between ascites due to portal hypertension-related and nonportal hypertension-related causes, and to compare results with the serum-ascites albumin gradient (SAAG). METHODS: The present study involved 142 patients with ascites presenting with diverse medical problems. Serum total protein, albumin, glucose, lactate dehydrogenase (LDH) levels and complete blood count were obtained for all subjects. Paracentesis was performed routinely on admission and all ascitic fluid samples were evaluated by manual cell count with differential, ascitic fluid culture and biochemistry (total protein, albumin, glucose and LDH). Cultures of ascitic fluid were performed at bedside in all patients using blood culture bottles. Ascitic fluid viscosity was measured in a commercially available cone and plate viscometer. RESULTS: Of the 142 patients studied, 34 (24%) had an SAAG of 11 g/L or less, whereas 108 (76%) had an SAAG of greater than 11 g/L. Sex and mean age did not differ significantly between the two groups (P>0.05). Serum total protein, albumin, glucose, LDH levels, leukocyte count, ascitic fluid glucose levels and ascitic fluid leukocyte counts were similar in both groups, with no statistically significant relationship detected (P>0.05). However, the mean (±SD) ascitic fluid total protein (0.0172±0.1104 g/L versus 0.043±0.011 g/L), albumin (0.0104±0.0064 g/L versus 0.0276±0.0069 g/L) and LDH (102.76±80.95 U/L versus 885.71±199.93 U/L) were found to be higher in patients with an SAAG of 11 g/L or less than in those with an SAAG of greater than 11 g/L (P<0.001). The mean ascitic fluid viscosities were 0.86±0.12 centipoise (cP) and 1.22±0.25 cP in patients with an SAAG greater than 11 g/L and an SAAG of 11 g/L or less, respectively (P<0.001). Although ascitic fluid infection was detected in 35 patients (24.6%) (19 patients with spontaneous bacterial peritonitis, seven patients with culture-negative neutrocytic ascites, three patients with monobacterial non-neutrocytic bacterascites and six patients with secondary bacterial peritonitis), no significant effect on ascitic fluid viscosity was detected. Multiple linear regression analysis revealed that ascitic fluid total protein, albumin and LDH levels were independent predictors of ascitic fluid viscosity (P<0.001). The sensitivity, specificity, and positive and negative predictive values of ascitic fluid viscosity for the discrimination between ascites due to portal hypertension-related and nonportal hypertension-related causes according to the SAAG were determined by receiver operating characteristic analysis. Regarding the cut-off value of 1.03 cP, ascitic fluid viscosity measurement had a high sensitivity, specificity (98% and 80%, respectively), and positive and negative predictive value (79% and 94%, respectively) for the etiological discrimination of ascites. CONCLUSION: The measurement of ascitic fluid viscosity correlates significantly with SAAG values. In view of its simplicity, low cost, small sample volume requirement and allowance for measurement in previously frozen samples, measurement of ascites viscosity could be useful for the accurate and rapid classification of ascites. PMID:20431815

  3. Development of Viscosity Model for Petroleum Industry Applications

    NASA Astrophysics Data System (ADS)

    Motahhari, Hamed reza

    Heavy oil and bitumen are challenging to produce and process due to their very high viscosity, but their viscosity can be reduced either by heating or dilution with a solvent. Given the key role of viscosity, an accurate viscosity model suitable for use with reservoir and process simulators is essential. While there are several viscosity models for natural gases and conventional oils, a compositional model applicable to heavy petroleum and diluents is lacking. The objective of this thesis is to develop a general compositional viscosity model that is applicable to natural gas mixtures, conventional crudes oils, heavy petroleum fluids, and their mixtures with solvents and other crudes. The recently developed Expanded Fluid (EF) viscosity correlation was selected as a suitable compositional viscosity model for petroleum applications. The correlation relates the viscosity of the fluid to its density over a broad range of pressures and temperatures. The other inputs are pressure and the dilute gas viscosity. Each fluid is characterized for the correlation by a set of fluid-specific parameters which are tuned to fit data. First, the applicability of the EF correlation was extended to asymmetric mixtures and liquid mixtures containing dissolved gas components. A new set of mass-fraction based mixing rules was developed to calculate the fluid-specific parameters for mixtures. The EF correlation with the new set of mixing rules predicted the viscosity of over 100 mixtures of hydrocarbon compounds and carbon dioxide with overall average absolute relative deviations (AARD) of less than 10% either with measured densities or densities estimated by Advanced Peng-Robinson equation of state (APR EoS). To improve the viscosity predictions with APR EoS-estimated densities, general correlations were developed for non-zero viscosity binary interaction parameters. The EF correlation was extended to non-hydrocarbon compounds typically encountered in natural gas industry. It was demonstrated that the framework of the correlation is valid for these compounds, except for compounds with strong hydrogen bonding such as water. A temperature dependency was introduced into the correlation for strongly hydrogen bonding compounds. The EF correlation fit the viscosity data of pure non-hydrocarbon compounds with AARDs below 6% and predicted the viscosity of sour and sweet natural gases and aqueous solutions of organic alcohols with overall AARDs less than 9%. An internally consistent estimation method was also developed to calculate the fluid-specific parameters for hydrocarbons when no experimental viscosity data are available. The method correlates the fluid-specific parameters to the molecular weight and specific gravity. The method was evaluated against viscosity data of over 250 pure hydrocarbon compounds and petroleum distillations cuts. The EF correlation predictions were found to be within the same order of magnitude of the measurements with an overall AARD of 31%. A methodology was then proposed to apply the EF viscosity correlation to crude oils characterized as mixtures of the defined components and pseudo-components. The above estimation methods are used to calculate the fluid-specific parameters for pseudo-components. Guidelines are provided for tuning of the correlation to available viscosity data, calculating the dilute gas viscosities, and improving the densities calculated with the Peng-Robinson EoS. The viscosities of over 10 dead and live crude oils and bitumen were predicted within a factor of 3 of the measured values using the measured density of the oils as the input. It was shown that single parameter tuning of the model improved the viscosity prediction to within 30% of the measured values. Finally, the performance of the EF correlation was evaluated for diluted heavy oils and bitumens. The required density and viscosity data were collected for over 20 diluted dead and live bitumen mixtures using an in-house capillary viscometer also equipped with an in-line density-meter at temperatures and pressures up to 175 °C and 10 MPa. The predictions of the correlation were found within the same order of magnitude of the measured values with overall AARDs less than 20%. It was shown that the predictions of the correlation with generalized non-zero interaction parameters for the solvent-oil pairs were improved to overall AARDs less than 10%.

  4. Stimulation of Mucin, Mucus, and Viscosity during Lubiprostone in Patients with Chronic Constipation may Potentially Lead to Increase of Lubrication.

    PubMed

    Majewski, Marek; Sarosiek, Irene; Wallner, Grzegorz; Edlavitch, Stanley A; Sarosiek, Jerzy

    2014-12-18

    The purpose of this clinical trial was to explore whether lubiprostone increases the rate of mucus and mucin secretion and its viscosity in chronic constipation (CC) patients. The secretion of chloride (CS) into the gastrointestinal tract lumen is pivotal in the body's ability to process non-digestible food components. CS sets the optimal rate of hydration for non-digestible food components, their fluidity, and their adequate propulsion along the alimentary tract. Chloride is also instrumental in the secretion of alimentary tract mucus, and the formation of a gel-like, viscous mucus-buffer layer. This layer acts as the first line and vanguard of the mucosal barrier. This barrier is essential in mucosal lubrication and protection. Lubiprostone, a novel chloride channel stimulator ClC-2, is currently approved for the treatment of CC. Its impact on mucus, mucus secretion, and viscosity is not established. A double-blind, crossover trial was approved by the IRBs at the Kansas University Medical Center (Kansas City, KS) (study site) and at the Texas Tech University HSC (El Paso, TX) (analysis site). The study included 20 patients (17 females (F); mean age: 37 years) with symptoms of CC diagnosed according to the Rome III criteria. Patients were randomized to 1 week of therapy with lubiprostone or placebo followed by a 1 week washout and 1 week of the alternative therapy. Gastric juice was collected basally and during stimulation with pentagastrin (6 μg/kg body weight subcutaneously) at the end of weeks 1 and 3. Pentagastrin stimulation mimics food stimulation. The mucus content in gastric juice was assessed gravimetrically. The mucin content was measured after its purification using ultracentrifugation. The viscosity of the gastric secretion was measured using a digital viscometer. In comparison with placebo, the volume of gastric secretion in patients with CC during administration of lubiprostone increased significantly by 50% (86.3 vs. 57.5 ml/h) (P<0.001) in basal conditions and increased by 25% (210.0 vs. 167.6 ml/h) (P=0.024) during stimulation with pentagastrin. The rate of gastric mucus secretion during therapy with lubiprostone was 91% higher (257.3 vs. 135 mg/h) (P=0.001) in basal conditions and 28% higher (348.1 vs. 270.8 mg/h) (NS) in stimulated conditions, although the latter was not statistically significant. The rate of gastric mucin secretion during lubiprostone therapy was 85% higher (98.4 vs. 65.5 mg/h) (P=0.011) in basal conditions and 38% (98.3 vs. 71.7 mg/h) (NS) higher in stimulated conditions. In basal conditions, the viscosity of gastric secretion during administration of lubiprostone increased by 240% at the lowest (P<0.001) and by 106% at the highest shear rate (P<0.001). In stimulated conditions, it increased by 226% (P<0.01) at the lowest shear rate and by 67% (P<0.01) at the highest shear rate. The significantly higher content of gastric mucus and mucin during therapy in basal conditions with lubiprostone in patients with CC suggests and supports the potentially leading role of lubiprostone and ClC-2 stimulation in their secretion. This increased stimulation results in profoundly increased viscosity, which in turn facilitates and/or accelerates the transit and evacuation of non-digestible food components. Although increases in mucus and mucin were observed in stimulated conditions, neither increase was statistically significant. Based on this experiment, we hypothesize that, in CC patients, the significantly increased rate of mucus and its major component, mucin secretion, during lubiprostone administration may partially explain its clinical effectiveness and also have additional clinically important effects. We propose that since the increased mucus production enhances the protective quality of the mucosal barrier, it also boosts its potential to withstand luminal aggressive components such as acid/pepsin duet, Helicobacter pylori and/or nonsteroidal anti-inflammatory drugs/aspirin, or a combination of all. Further trials are needed to test this hypothesis. As this was crossover clinical trial, the patients serve as their own controls. No interaction was found with body mass index (BMI) and treatment. The observed relationships of BMI and mucus and mucin secretions and gastric juice volume are important considerations in the design of future trials, particularly if a crossover design is not used.

  5. Stimulation of Mucin, Mucus, and Viscosity during Lubiprostone in Patients with Chronic Constipation may Potentially Lead to Increase of Lubrication

    PubMed Central

    Majewski, Marek; Sarosiek, Irene; Wallner, Grzegorz; Edlavitch, Stanley A; Sarosiek, Jerzy

    2014-01-01

    Objectives: The purpose of this clinical trial was to explore whether lubiprostone increases the rate of mucus and mucin secretion and its viscosity in chronic constipation (CC) patients. The secretion of chloride (CS) into the gastrointestinal tract lumen is pivotal in the body's ability to process non-digestible food components. CS sets the optimal rate of hydration for non-digestible food components, their fluidity, and their adequate propulsion along the alimentary tract. Chloride is also instrumental in the secretion of alimentary tract mucus, and the formation of a gel-like, viscous mucus-buffer layer. This layer acts as the first line and vanguard of the mucosal barrier. This barrier is essential in mucosal lubrication and protection. Lubiprostone, a novel chloride channel stimulator ClC-2, is currently approved for the treatment of CC. Its impact on mucus, mucus secretion, and viscosity is not established. Methods: A double-blind, crossover trial was approved by the IRBs at the Kansas University Medical Center (Kansas City, KS) (study site) and at the Texas Tech University HSC (El Paso, TX) (analysis site). The study included 20 patients (17 females (F); mean age: 37 years) with symptoms of CC diagnosed according to the Rome III criteria. Patients were randomized to 1 week of therapy with lubiprostone or placebo followed by a 1 week washout and 1 week of the alternative therapy. Gastric juice was collected basally and during stimulation with pentagastrin (6 μg/kg body weight subcutaneously) at the end of weeks 1 and 3. Pentagastrin stimulation mimics food stimulation. The mucus content in gastric juice was assessed gravimetrically. The mucin content was measured after its purification using ultracentrifugation. The viscosity of the gastric secretion was measured using a digital viscometer. Results: In comparison with placebo, the volume of gastric secretion in patients with CC during administration of lubiprostone increased significantly by 50% (86.3 vs. 57.5 ml/h) (P<0.001) in basal conditions and increased by 25% (210.0 vs. 167.6 ml/h) (P=0.024) during stimulation with pentagastrin. The rate of gastric mucus secretion during therapy with lubiprostone was 91% higher (257.3 vs. 135 mg/h) (P=0.001) in basal conditions and 28% higher (348.1 vs. 270.8 mg/h) (NS) in stimulated conditions, although the latter was not statistically significant. The rate of gastric mucin secretion during lubiprostone therapy was 85% higher (98.4 vs. 65.5 mg/h) (P=0.011) in basal conditions and 38% (98.3 vs. 71.7 mg/h) (NS) higher in stimulated conditions. In basal conditions, the viscosity of gastric secretion during administration of lubiprostone increased by 240% at the lowest (P<0.001) and by 106% at the highest shear rate (P<0.001). In stimulated conditions, it increased by 226% (P<0.01) at the lowest shear rate and by 67% (P<0.01) at the highest shear rate. Conclusions: The significantly higher content of gastric mucus and mucin during therapy in basal conditions with lubiprostone in patients with CC suggests and supports the potentially leading role of lubiprostone and ClC-2 stimulation in their secretion. This increased stimulation results in profoundly increased viscosity, which in turn facilitates and/or accelerates the transit and evacuation of non-digestible food components. Although increases in mucus and mucin were observed in stimulated conditions, neither increase was statistically significant. Based on this experiment, we hypothesize that, in CC patients, the significantly increased rate of mucus and its major component, mucin secretion, during lubiprostone administration may partially explain its clinical effectiveness and also have additional clinically important effects. We propose that since the increased mucus production enhances the protective quality of the mucosal barrier, it also boosts its potential to withstand luminal aggressive components such as acid/pepsin duet, Helicobacter pylori and/or nonsteroidal anti-inflammatory drugs/aspirin, or a combination of all. Further trials are needed to test this hypothesis. As this was crossover clinical trial, the patients serve as their own controls. No interaction was found with body mass index (BMI) and treatment. The observed relationships of BMI and mucus and mucin secretions and gastric juice volume are important considerations in the design of future trials, particularly if a crossover design is not used. PMID:25521039

  6. Analysis and reconstructed modelling of the debris flow event of the 21st of July 2012 of St. Lorenzen (Styria, Austira)

    NASA Astrophysics Data System (ADS)

    Janu, Stefan; Mehlhorn, Susanne; Moser, Markus

    2013-04-01

    Analysis and reconstructed modelling of the debris flow event of the 21st of July 2012 of St. Lorenzen (Styria, Austria) Authors: Stefan Janu, Susanne Mehlhorn, Markus Moser The village of St. Lorenzen, in the Styrian Palten valley is situated on the banks of the Lorenz torrent, in which a debris flow event occurred in the early morning hours of the 21st of July 2012, causing catastrophic damage to residential buildings and other infrastructural facilities. In the ministry-approved hazard zone map of 2009, the flood water discharge and bedload volume associated with a 150-year event was estimated at 34 m³/s and 25,000 m³ respectively for the 5.84 km² catchment area. The bedload transport capacity of the torrent was classified as ranging from 'heavy' to 'capable of producing debris flows'. The dominant process type of the mass movement event may be described as a fine-grained debris flow. The damage in the residential area of St.Lorenzen was caused by a debris flow pulse in the lower reach of the Lorenz torrent. This debris flow pulse was in turn caused by numerous landslides along the middle reaches of the torrent, some of which caused blockages, ultimately leading to an outburst event in the main torrent. Discharge cross-sections ranging from 65 - 90 m², and over 100 m² in a few instances, were measured upstream of the St. Lorenzen residential area. Back-calculations of velocities yielded an average debris flow velocity along the middle reaches of the torrent between 11 and 16 m/s. An average velocity of 9 m/s was calculated for the debris flow at the neck of the alluvial fan directly behind the center of the village. Due to both the high discharge values as well as to the height of the mass movement deposits, the natural hazard event of 21 July 2012 in St. Lorenzen is clearly to be described as having had an extreme intensity. A total of 67 buildings were damaged along the Lorenz torrent, 7 of were completely destroyed. According to the Austrian Service for Torrent and Avalanche Control, a great number of protection measures have in the past been realized in the Lorenz torrent, which with certainty contributed significantly to an even greater amount of damage in the St. Lorenz residential area having been prevented. Attempts at reconstructing the event processes as well simulating the debris flow in 2D were undertaken in the course of the event documentation and analysis. The thus obtained discharge heights, flow velocities and impact pressure values corresponded with the well documented event. The two dimensional simulations were carried out with the program FLO-2D, which is capable of simulating debris flows. The rheological parameters of the debris flow material were determined with the aid of a viscometer and a debris rotation drum. The debris flow hydrograph, bedload and bedload ratio were reconstructed using data from the event documentation, such as difference models, geological mapping, wetted perimeters, witness's statements, etc. The aim of the very detailed event documentation and analysis was to reconstruct the extreme process sequence along with the damaging effects that they had in the build-up area of St. Lorenzen. There was a large media interest in this event. The results should therefore serve to answer the multitude of questions about this event that lie in the public as well political interests. Additional and substantial protection measures were also planned for the village of St. Lorenzen on the basis of these event analysis results. These are comprised of two debris flow barriers in the lower gorge streches with a capacity of 15,000 m³ each as well as a bedload retention basin directly above, with a capacity of 30,000 m³. Construction of these technical protection measures has already begun. Authoŕs adresses: DI Stefan Janu Fachbereich Wildbachprozesse Austrian Service for Torrent and Avalanche Control, GBL Ennstal und Salzatal Schönaustraße 50 8940 Liezen Dipl.Geogr. Susanne Mehlhorn Fachbereich Wildbachprozesse Austrian Service for Torrent and Avalanche Control, BMLFUW Abt. IV/5 Marxergasse 2 1030 Wien DI Markus Moser Fachbereich Wildbachprozesse Austrian Service for Torrent and Avalanche Control, GBL Lungau Johann Löcker Str. 3 5580 Tamsweg

Top