... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...
Role of optometry school in single day large scale school vision testing
Anuradha, N; Ramani, Krishnakumar
2015-01-01
Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271
New color vision tests to evaluate faulty color recognition.
Nakamura, Kaoru; Okajima, Osamu; Nishio, Yoshiteru; Kitahara, Kenji
2002-01-01
To develop and assess new color vision tests to be used in evaluating faulty color recognition. We developed new color vision tests to evaluate faulty color recognition. The two types of color vision tests, designed to assess faulty color recognition in color vision deficiencies, are based on principles that are different from those of the conventional color vision tests. In the first test plate, the subject is asked to choose either a red, green, or gray line from among 10 lines that are randomly colored red, green, gray, yellow, or blue. The score is the difference between the number of correct answers and the number of incorrect answers. In the second test plate, the subject is asked to identify a total of 10 red azalea blossoms, which are dispersed among numerous green leaves. Seventy-five persons with congenital color deficiencies and 20 subjects with normal color vision were examined using these new test plates. The scores differed significantly between dichromats and anomalous trichromats, and between anomalous trichromats and subjects with normal color vision. The new tests are easy to use, sensitive, and have good reproducibility for use in discriminating subjects with color vision anomalies. These tests reveal the faulty color recognition that occurs unconsciously in persons with color deficiencies, and are useful in judging the quantification of color vision required in their daily life and occupations.
Insights into Inpatients with Poor Vision: A High Value Proposition
Press, Valerie G.; Matthiesen, Madeleine I.; Ranadive, Alisha; Hariprasad, Seenu M.; Meltzer, David O.; Arora, Vineet M.
2015-01-01
Background Vision impairment is an under-recognized risk factor for adverse events among hospitalized patients, yet vision is neither routinely tested nor documented for inpatients. Low-cost ($8 and up) non-prescription ‘readers’ may be a simple, high-value intervention to improve inpatients’ vision. We aimed to study initial feasibility and efficacy of screening and correcting inpatients’ vision. Methods From June 2012 through January 2014 we began testing whether participants’ vision corrected with non-prescription lenses for eligible participants failing a vision screen (Snellen chart) performed by research assistants (RAs). Descriptive statistics and tests of comparison, including t-tests and chi-squared tests, were used when appropriate. All analyses were performed using Stata version 12 (StataCorps, College Station, TX). Results Over 800 participants’ vision was screened (n=853). Older (≥65 years; 56%) participants were more likely to have insufficient vision than younger (<65 years; 28%; p<0.001). Non-prescription readers corrected the majority of eligible participants’ vision (82%, 95/116). Discussion Among an easily identified sub-group of inpatients with poor vision, low-cost ‘readers’ successfully corrected most participants’ vision. Hospitalists and other clinicians working in the inpatient setting can play an important role in identifying opportunities to provide high-value care related to patients’ vision. PMID:25755206
Operational Based Vision Assessment Automated Vision Test Collection User Guide
2017-05-15
repeatability to support correlation analysis. The AVT research grade tests also support interservice, international, industry, and academic partnerships...software, provides information concerning various menu options and operation of the test, and provides a brief description of each of the automated vision...2802, 6 Jun 2017. TABLE OF CONTENTS (concluded) Section Page 7.0 OBVA VISION TEST DESCRIPTIONS
Dain, Stephen J
2004-07-01
The structure and function of the available and significant clinical colour vision tests are reviewed in the light of the needs in the clinical examination of congenital and acquired colour vision deficiencies. The tests are grouped and described as pseudo-isochromatic plates, arrangement tests, matching tests and vocational tests. The colorimetric constructions of the test types are described and the efficiency of their performance and usefulness discussed. Recommendations are made for basic and extended test batteries, when examining of congenital and acquired colour vision deficiencies in the consulting room.
A new color vision test to differentiate congenital and acquired color vision defects.
Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak
2007-07-01
To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency. Observational cross-sectional study. Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004. To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. Error scores and ratio in quadrant analysis of the Seohan computerized hue test. The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval). The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.
16 CFR 1203.14 - Peripheral vision test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...
16 CFR 1203.14 - Peripheral vision test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...
Vision and night driving abilities of elderly drivers.
Gruber, Nicole; Mosimann, Urs P; Müri, René M; Nef, Tobias
2013-01-01
In this article, we review the impact of vision on older people's night driving abilities. Driving is the preferred and primary mode of transport for older people. It is a complex activity where intact vision is seminal for road safety. Night driving requires mesopic rather than scotopic vision, because there is always some light available when driving at night. Scotopic refers to night vision, photopic refers to vision under well-lit conditions, and mesopic vision is a combination of photopic and scotopic vision in low but not quite dark lighting situations. With increasing age, mesopic vision decreases and glare sensitivity increases, even in the absence of ocular diseases. Because of the increasing number of elderly drivers, more drivers are affected by night vision difficulties. Vision tests, which accurately predict night driving ability, are therefore of great interest. We reviewed existing literature on age-related influences on vision and vision tests that correlate or predict night driving ability. We identified several studies that investigated the relationship between vision tests and night driving. These studies found correlations between impaired mesopic vision or increased glare sensitivity and impaired night driving, but no correlation was found among other tests; for example, useful field of view or visual field. The correlation between photopic visual acuity, the most commonly used test when assessing elderly drivers, and night driving ability has not yet been fully clarified. Photopic visual acuity alone is not a good predictor of night driving ability. Mesopic visual acuity and glare sensitivity seem relevant for night driving. Due to the small number of studies evaluating predictors for night driving ability, further research is needed.
Wearable Improved Vision System for Color Vision Deficiency Correction
Riccio, Daniel; Di Perna, Luigi; Sanniti Di Baja, Gabriella; De Nino, Maurizio; Rossi, Settimio; Testa, Francesco; Simonelli, Francesca; Frucci, Maria
2017-01-01
Color vision deficiency (CVD) is an extremely frequent vision impairment that compromises the ability to recognize colors. In order to improve color vision in a subject with CVD, we designed and developed a wearable improved vision system based on an augmented reality device. The system was validated in a clinical pilot study on 24 subjects with CVD (18 males and 6 females, aged 37.4 ± 14.2 years). The primary outcome was the improvement in the Ishihara Vision Test score with the correction proposed by our system. The Ishihara test score significantly improved (\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$p = 0.03$ \\end{document}) from 5.8 ± 3.0 without correction to 14.8 ± 5.0 with correction. Almost all patients showed an improvement in color vision, as shown by the increased test scores. Moreover, with our system, 12 subjects (50%) passed the vision color test as normal vision subjects. The development and preliminary validation of the proposed platform confirm that a wearable augmented-reality device could be an effective aid to improve color vision in subjects with CVD. PMID:28507827
Finkelstein, Marsha; Llanos, Imelda; Scheiman, Mitchell; Wagener, Sharon Gowdy
2014-01-01
Vision impairment is common in the first year after traumatic brain injury (TBI), including among service members whose brain injuries occurred during deployment in Iraq and Afghanistan. Occupational therapy practitioners provide routine vision screening to inform treatment planning and referral to vision specialists, but existing methods are lacking because many tests were developed for children and do not screen for vision dysfunction typical of TBI. An expert panel was charged with specifying the composition of a vision screening protocol for servicemembers with TBI. A modified nominal group technique fostered discussion and objective determinations of consensus. After considering 29 vision tests, the panel recommended a nine-test vision screening that examines functional performance, self-reported problems, far–near acuity, reading, accommodation, convergence, eye alignment and binocular vision, saccades, pursuits, and visual fields. Research is needed to develop reliable, valid, and clinically feasible vision screening protocols to identify TBI-related vision disorders in adults. PMID:25005505
29 CFR 1630.10 - Qualification standards, tests, and other selection criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... business necessity. (b) Qualification standards and tests related to uncorrected vision. Notwithstanding..., or other selection criteria based on an individual's uncorrected vision unless the standard, test, or... application of a qualification standard, test, or other criterion based on uncorrected vision need not be a...
Chow, Alan Y.; Bittner, Ava K.; Pardue, Machelle T.
2010-01-01
Purpose: In a published pilot study, a light-activated microphotodiode-array chip, the artificial silicon retina (ASR), was implanted subretinally in 6 retinitis pigmentosa (RP) patients for up to 18 months. The ASR electrically induced retinal neurotrophic rescue of visual acuity, contrast, and color perception and raised several questions: (1) Would neurotrophic effects develop and persist in additionally implanted RP patients? (2) Could vision in these patients be reliably assessed? (3) Would the ASR be tolerated and function for extended periods? Methods: Four additional RP patients were implanted and observed along with the 6 pilot patients. Of the 10 patients, 6 had vision levels that allowed for more standardized testing and were followed up for 7+ years utilizing ETDRS charts and a 4-alternative forced choice (AFC) Chow grating acuity test (CGAT). A 10-AFC Chow color test (CCT) extended the range of color vision testing. Histologic examination of the eyes of one patient, who died of an unrelated event, was performed. Results: The ASR was well tolerated, and improvement and/or slowing of vision loss occurred in all 6 patients. CGAT extended low vision acuity testing by logMAR 0.6. CCT expanded the range of color vision testing and correlated well with PV-16 (r = 0.77). An ASR recovered from a patient 5 years after implantation showed minor disruption and excellent electrical function. Conclusion: ASR-implanted RP patients experienced prolonged neurotrophic rescue of vision. CGAT and CCT extended the range of acuity and color vision testing in low vision patients. ASR implantation may improve and prolong vision in RP patients. PMID:21212852
Static and dynamic postural control in low-vision and normal-vision adults.
Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D
2013-04-01
This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.
Evaluation of the Waggoner Computerized Color Vision Test.
Ng, Jason S; Self, Eriko; Vanston, John E; Nguyen, Andrew L; Crognale, Michael A
2015-04-01
Clinical color vision evaluation has been based primarily on the same set of tests for the past several decades. Recently, computer-based color vision tests have been devised, and these have several advantages but are still not widely used. In this study, we evaluated the Waggoner Computerized Color Vision Test (CCVT), which was developed for widespread use with common computer systems. A sample of subjects with (n = 59) and without (n = 361) color vision deficiency (CVD) were tested on the CCVT, the anomaloscope, the Richmond HRR (Hardy-Rand-Rittler) (4th edition), and the Ishihara test. The CCVT was administered in two ways: (1) on a computer monitor using its default settings and (2) on one standardized to a correlated color temperature (CCT) of 6500 K. Twenty-four subjects with CVD performed the CCVT both ways. Sensitivity, specificity, and correct classification rates were determined. The screening performance of the CCVT was good (95% sensitivity, 100% specificity). The CCVT classified subjects as deutan or protan in agreement with anomaloscopy 89% of the time. It generally classified subjects as having a more severe defect compared with other tests. Results from 18 of the 24 subjects with CVD tested under both default and calibrated CCT conditions were the same, whereas the results from 6 subjects had better agreement with other test results when the CCT was set. The Waggoner CCVT is an adequate color vision screening test with several advantages and appears to provide a fairly accurate diagnosis of deficiency type. Used in conjunction with other color vision tests, it may be a useful addition to a color vision test battery.
Color Vision and the Railways: Part 1. The Railway LED Lantern Test.
Dain, Stephen J; Casolin, Armand; Long, Jennifer; Hilmi, Mohd Radzi
2015-02-01
Lantern tests and practical tests are often used in the assessment of prospective railway employees. The lantern tests rarely embody the actual colors used in signaling on the railways. Practical tests have a number of problems, most notably consistency of application and practicability. This work was carried out to provide the Railway LED Lantern Test (RLLT) as a validated method of assessing the color vision of railway workers. The RLLT, a simulated practical test using the same LEDs (light-emitting diodes) as are used in modern railway signals, was developed. It was tested on 46 color vision-normal (CVN) and 37 color vision-deficient (CVD) subjects. A modified prototype was then tested on 106 CVN subjects. All 106 CVN subjects and most mildly affected CVD subjects passed the modified lantern at 3 m. At 6 m, 1 of the 106 normal color vision subjects failed by missing a single red light. All the CVD subjects failed. The RLLT carried out at 3 m allowed mildly affected CVD subjects to pass and demonstrate adequate color vision for the less demanding railway tasks. Carried out at 6 m, it essentially reinforced normal color vision as the standard. The RLLT is a simply administered test that has a direct link to the actual visual task of the rail worker. The RLLT lantern has been adopted as an approved test in the Australian National Standard for Health Assessment of Rail Safety Workers in place of a practical test. It has the potential to be a valid part of any railway color vision standard.
Hypoxia, color vision deficiencies, and blood oxygen saturation.
DOT National Transportation Integrated Search
2013-11-01
Chromatic thresholds were measured using the Cambridge Color Test (CCT), Color Assessment and Diagnosis : (CAD) test, and Cone Specific Contrast Test at ground and 3780 m (12,400 ft) for subjects with normal color : vision and red-green color vision ...
DOT National Transportation Integrated Search
1990-08-01
An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...
Detection of color vision defects in chloroquine retinopathy.
Vu, B L; Easterbrook, M; Hovis, J K
1999-09-01
The effect of chloroquine toxicity on color vision is unclear. The authors identified the color defects seen in chloroquine retinopathy and determined the sensitivity and specificity of clinical color vision tests for detecting the presence of previously diagnosed chloroquine retinopathy. Case-control study. Chloroquine retinopathy was defined using previously published criteria. Data from 30 patients with retinopathy and 25 patients using chloroquine but with no evidence of retinal toxicity were collected. All patients were tested with the following six clinical color vision tests: Ishihara, Farnsworth D-15, and Adams Desaturated-15 (Dsat-15), City University 2nd Edition (CU), Standard Pseudoisochromatic Plates Part 2 (SPP-2), and American Optical Hardy Rand Rittler (AO HRR). The number of failures was determined for each test. The types of color vision defects were classified as blue-yellow (BY), red-green (RG), or mixed RG and BY (mixed). Of the 30 patients with retinopathy, 28 (93.3%) of 30 patients failed at least 1 color vision test, demonstrating predominantly mixed defects. Five (25%) of 25 of the control subjects failed at least 1 test, and these defects were predominantly BY. The sensitivity and specificity of the tests are as follows: SPP-2 (93.3%, 88%), AO HRR (76.7%, 88%), Ishihara (43.3%, 96%), Dsat-15 (33.3%, 84%), D-15 (16.7%, 96%), and CU (20%, 92%). Color vision can be affected by chloroquine and should be tested routinely with a color vision test designed to detect both mild BY and protan RG defects to maximize sensitivity for toxicity. The SPP-2 and AO HRR are two tests that meet these criteria. The Ishihara has a low sensitivity, as do the D-15 tests and CU. All of the tests have similar specificity for chloroquine toxicity. If color vision defects are detected in patients at risk of developing chloroquine retinopathy, additional testing is indicated to rule out toxicity.
Can the Farnsworth D15 Color Vision Test Be Defeated through Practice?
Ng, Jason S; Liem, Sophia C
2018-05-01
This study suggests that it is possible for some patients with severe red-green color vision deficiency to do perfectly on the Farnsworth D15 test after practicing it. The Farnsworth D15 is a commonly used test to qualify people for certain occupations. For patients with color vision deficiency, there may be high motivation to try to pass the test through practice to gain entry into a particular occupation. There is no evidence in the literature on whether it is possible for patients to learn to pass the D15 test through practice. Ten subjects with inherited red-green color vision deficiency and 15 color-normal subjects enrolled in the study. All subjects had anomaloscope testing, color vision book tests, and a Farnsworth D15 at an initial visit. For the D15, the number of major crossovers was determined for each subject. Failing the D15 was determined as greater than 1 major crossover. Subjects with color vision deficiency practiced the D15 as long as desired to achieve a perfect score and then returned for a second visit for D15 testing. A paired t test was used to analyze the number of major crossovers at visit 1 versus visit 2. Color-normal subjects did not have any major crossovers. Subjects with color vision deficiency had significantly (P < .001) fewer major crossovers on the D15 test at visit 2 (mean/SD = 2.5/3.0), including five subjects with dichromacy that achieved perfect D15 performance, compared to visit 1 (mean/SD = 8.7/1.3). Practice of the Farnsworth D15 test can lead to perfect performance for some patients with color vision deficiency, and this should be considered in certain cases where occupational entry is dependent on D15 testing.
Color vision test for dichromatic and trichromatic macaque monkeys.
Koida, Kowa; Yokoi, Isao; Okazawa, Gouki; Mikami, Akichika; Widayati, Kanthi Arum; Miyachi, Shigehiro; Komatsu, Hidehiko
2013-11-01
Dichromacy is a color vision defect in which one of the three cone photoreceptors is absent. Individuals with dichromacy are called dichromats (or sometimes "color-blind"), and their color discrimination performance has contributed significantly to our understanding of color vision. Macaque monkeys, which normally have trichromatic color vision that is nearly identical to humans, have been used extensively in neurophysiological studies of color vision. In the present study we employed two tests, a pseudoisochromatic color discrimination test and a monochromatic light detection test, to compare the color vision of genetically identified dichromatic macaques (Macaca fascicularis) with that of normal trichromatic macaques. In the color discrimination test, dichromats could not discriminate colors along the protanopic confusion line, though trichromats could. In the light detection test, the relative thresholds for longer wavelength light were higher in the dichromats than the trichromats, indicating dichromats to be less sensitive to longer wavelength light. Because the dichromatic macaque is very rare, the present study provides valuable new information on the color vision behavior of dichromatic macaques, which may be a useful animal model of human dichromacy. The behavioral tests used in the present study have been previously used to characterize the color behaviors of trichromatic as well as dichromatic new world monkeys. The present results show that comparative studies of color vision employing similar tests may be feasible to examine the difference in color behaviors between trichromatic and dichromatic individuals, although the genetic mechanisms of trichromacy/dichromacy is quite different between new world monkeys and macaques.
ERIC Educational Resources Information Center
Chen, Deborah
This videotape explains common vision tests used with infants with multiple disabilities, shows how to gather information from parents on their children's use of vision, and demonstrates selected early intervention strategies for encouraging infants and young children with multiple disabilities to use their vision in functional ways. The videotape…
Predicting Visual Disability in Glaucoma With Combinations of Vision Measures.
Lin, Stephanie; Mihailovic, Aleksandra; West, Sheila K; Johnson, Chris A; Friedman, David S; Kong, Xiangrong; Ramulu, Pradeep Y
2018-04-01
We characterized vision in glaucoma using seven visual measures, with the goals of determining the dimensionality of vision, and how many and which visual measures best model activity limitation. We analyzed cross-sectional data from 150 older adults with glaucoma, collecting seven visual measures: integrated visual field (VF) sensitivity, visual acuity, contrast sensitivity (CS), area under the log CS function, color vision, stereoacuity, and visual acuity with noise. Principal component analysis was used to examine the dimensionality of vision. Multivariable regression models using one, two, or three vision tests (and nonvisual predictors) were compared to determine which was best associated with Rasch-analyzed Glaucoma Quality of Life-15 (GQL-15) person measure scores. The participants had a mean age of 70.2 and IVF sensitivity of 26.6 dB, suggesting mild-to-moderate glaucoma. All seven vision measures loaded similarly onto the first principal component (eigenvectors, 0.220-0.442), which explained 56.9% of the variance in vision scores. In models for GQL scores, the maximum adjusted- R 2 values obtained were 0.263, 0.296, and 0.301 when using one, two, and three vision tests in the models, respectively, though several models in each category had similar adjusted- R 2 values. All three of the best-performing models contained CS. Vision in glaucoma is a multidimensional construct that can be described by several variably-correlated vision measures. Measuring more than two vision tests does not substantially improve models for activity limitation. A sufficient description of disability in glaucoma can be obtained using one to two vision tests, especially VF and CS.
Vision training methods for sports concussion mitigation and management.
Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon
2015-05-05
There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.
Pye, Annie; Charalambous, Anna Pavlina; Leroi, Iracema; Thodi, Chrysoulla; Dawes, Piers
2017-11-01
Cognitive screening tests frequently rely on items being correctly heard or seen. We aimed to identify, describe, and evaluate the adaptation, validity, and availability of cognitive screening and assessment tools for dementia which have been developed or adapted for adults with acquired hearing and/or vision impairment. Electronic databases were searched using subject terms "hearing disorders" OR "vision disorders" AND "cognitive assessment," supplemented by exploring reference lists of included papers and via consultation with health professionals to identify additional literature. 1,551 papers were identified, of which 13 met inclusion criteria. Four papers related to tests adapted for hearing impairment; 11 papers related to tests adapted for vision impairment. Frequently adapted tests were the Mini-Mental State Examination (MMSE) and the Montreal Cognitive Assessment (MOCA). Adaptations for hearing impairment involved deleting or creating written versions for hearing-dependent items. Adaptations for vision impairment involved deleting vision-dependent items or spoken/tactile versions of visual tasks. No study reported validity of the test in relation to detection of dementia in people with hearing/vision impairment. Item deletion had a negative impact on the psychometric properties of the test. While attempts have been made to adapt cognitive tests for people with acquired hearing and/or vision impairment, the primary limitation of these adaptations is that their validity in accurately detecting dementia among those with acquired hearing or vision impairment is yet to be established. It is likely that the sensitivity and specificity of the adapted versions are poorer than the original, especially if the adaptation involved item deletion. One solution would involve item substitution in an alternative sensory modality followed by re-validation of the adapted test.
Development of a battery of functional tests for low vision.
Dougherty, Bradley E; Martin, Scott R; Kelly, Corey B; Jones, Lisa A; Raasch, Thomas W; Bullimore, Mark A
2009-08-01
We describe the development and evaluation of a battery of tests of functional visual performance of everyday tasks intended to be suitable for assessment of low vision patients. The functional test battery comprises-Reading rate: reading aloud 20 unrelated words for each of four print sizes (8, 4, 2, & 1 M); Telephone book: finding a name and reading the telephone number; Medicine bottle label: reading the name and dosing; Utility bill: reading the due date and amount due; Cooking instructions: reading cooking time on a food package; Coin sorting: making a specified amount from coins placed on a table; Playing card recognition: identifying denomination and suit; and Face recognition: identifying expressions of printed, life-size faces at 1 and 3 m. All tests were timed except face and playing card recognition. Fourteen normally sighted and 24 low vision subjects were assessed with the functional test battery. Visual acuity, contrast sensitivity, and quality of life (National Eye Institute Visual Function Questionnaire 25 [NEI-VFQ 25]) were measured and the functional tests repeated. Subsequently, 23 low vision patients participated in a pilot randomized clinical trial with half receiving low vision rehabilitation and half a delayed intervention. The functional tests were administered at enrollment and 3 months later. Normally sighted subjects could perform all tasks but the proportion of trials performed correctly by the low vision subjects ranged from 35% for face recognition at 3 m, to 95% for the playing card identification. On average, low vision subjects performed three times slower than the normally sighted subjects. Timed tasks with a visual search component showed poorer repeatability. In the pilot clinical trial, low vision rehabilitation produced the greatest improvement for the medicine bottle and cooking instruction tasks. Performance of patients on these functional tests has been assessed. Some appear responsive to low vision rehabilitation.
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J., III; Kramer, Lynda J.; Arthur, Jarvis J., III
2005-01-01
Research was conducted onboard a Gulfstream G-V aircraft to evaluate integrated Synthetic Vision System concepts during flight tests over a 6-week period at the Wallops Flight Facility and Reno/Tahoe International Airport. The NASA Synthetic Vision System incorporates database integrity monitoring, runway incursion prevention alerting, surface maps, enhanced vision sensors, and advanced pathway guidance and synthetic terrain presentation. The paper details the goals and objectives of the flight test with a focus on the situation awareness benefits of integrating synthetic vision system enabling technologies for commercial aircraft.
Khosla, Amrit; Maini, Anuj Paul; Wangoo, Anuj; Singh, Sukhman; Mehar, Damanpreet Kaur
2017-01-01
The success of a restoration is dependent on accurate shade matching of teeth leading to studies evaluating the factors affecting the perception of shades. Colour vision anomalies including colour blindness have been found to exist in the population and it has been thought to be a potential factor affecting the colour perception ability. The present study was done to evaluate the prevalence of colour vision anomalies and its effect on matching of shades of teeth. A total of 147 dental professionals were randomly selected for the study and were first tested for visual acuity using the Snellen's Eye Chart so as to carry on the study with only those operators who had a vision of 6/6. Then, the Ishihara's colour charts were used to test the operators for colour vision handicap. In the last stage of the study, test for accuracy of shade selection was done using the Vitapan Classical shade guide. The shade guide tabs were covered to avoid bias. Percentage was used to calculate the prevalence of colour vision handicap and its effect on matching of shades of teeth as compared to normal vision, which was evaluated using Chi square test. Nineteen operators had colour vision anomalies out of hundred operators and only two operators presented with colour blindness. Colour vision anomaly was more prevalent than colour blindness and it was also found that it was more prevalent in males than females. The difference between the accuracy of shade matching between the operators with normal vision and colour vision defect and operators with normal vision and colour blindness was statistically not significant. Colour blindness and colour vision handicap are rare conditions, with the latter being more common in the population. According to our study, it was concluded that no statistically significant difference existed amongst the operators with normal vision and colour vision anomaly or operators with normal vision and colour blindness during the matching of shades of teeth.
Jass, C M; Böhringer, D; Erb, C; Jordan, J F
2013-11-01
Glaucoma is an ocular disease with typical progressive damage of the optic nerve. In the past it was postulated that glaucoma induces acquired colour vision disorders. Until now all studies about glaucoma and colour vision disorders did not include vascular risk factors. In the present study we determined several vascular risk factors concerning the results of the colour vision test Roth 28-hue (E) desaturated in glaucoma patients. On the basis of an analysis of variance (ANOVA) we determined the influence of several risk factors, such as arteriosclerotic and vasospastic risk factors, on the results of the colour vision test Roth 28-hue (E) desaturated in glaucoma patients. 353 glaucoma patients were included in this study. We detected a strong influence of age and mean defect in perimetry and an additional effect of arteriosclerotic and vasospastic risk factors on the results of the colour vision test Roth 28-hue (E) desaturated in glaucoma patients. We suspect that arteriosclerotic and vasospastic risk factors independently to glaucoma have an influence on colour vision. In the future attention additionally has to be given to vascular risk factors in the colour vision testing of glaucoma patients. Georg Thieme Verlag KG Stuttgart · New York.
Gregori, Bruno; Papazachariadis, Odysseas; Farruggia, Alfonsa; Accornero, Neri
2011-01-15
Optic neuritis related to multiple sclerosis and diabetic retinopathy are relatively selective post-retinal and retinal vision disorders. Vision impairment in both conditions is reliably measured by testing critical fusion frequency (CFF). To examine color vision, we measured the CFF in response to red and blue stimuli, and tested CFF values in patients without evident vision impairment. To ensure that differences in CFF values in a given subject depended only on color perception we displayed red and blue flickering stimuli at equal luminance. CFF to red or blue stimuli were compared in patients with medical history of optic neuritis related to multiple sclerosis (post-retinal vision impairment), patients with diabetic retinopathy (retinal vision impairment) and healthy subjects. The test procedure disclosed altered CFF values for red and blue stimuli in both groups of patients studied. The comparison between the two groups disclosed a prevalent CFF impairment for red stimuli in patients with optic neuritis related to multiple sclerosis and for blue stimuli in patients with diabetic retinopathy. The differential color flicker test appears highly accurate in detecting color vision impairment. Comparison of the two color CFFs differentiates retinal from post-retinal visual disorders. Copyright © 2010 Elsevier B.V. All rights reserved.
Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.
Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E
2017-05-01
To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.
Vision Care and the Nation's Children.
ERIC Educational Resources Information Center
American Optometric Association, St. Louis, MO.
Aspects of vision and vision care considered are the following: extent and types of vision defects of American children; importance of vision care in pre-school years, elementary, and secondary school and beyond; and manpower resources in vision care today, the extent of vision testing and care, special problem areas, and governmental support.…
Design of a dynamic test platform for autonomous robot vision systems
NASA Technical Reports Server (NTRS)
Rich, G. C.
1980-01-01
The concept and design of a dynamic test platform for development and evluation of a robot vision system is discussed. The platform is to serve as a diagnostic and developmental tool for future work with the RPI Mars Rover's multi laser/multi detector vision system. The platform allows testing of the vision system while its attitude is varied, statically or periodically. The vision system is mounted on the test platform. It can then be subjected to a wide variety of simulated can thus be examined in a controlled, quantitative fashion. Defining and modeling Rover motions and designing the platform to emulate these motions are also discussed. Individual aspects of the design process are treated separately, as structural, driving linkages, and motors and transmissions.
NASA Technical Reports Server (NTRS)
Van Baalen, Mary; Mason, Sara; Foy, Millennia; Wear, Mary; Taiym, Wafa; Moynihan, Shannan; Alexander, David; Hart, Steve; Tarver, William
2015-01-01
Due to recently identified vision changes associated with space flight, JSC Space and Clinical Operations (SCO) implemented broad mission-related vision testing starting in 2009. Optical Coherence Tomography (OCT), 3 Tesla Brain and Orbit MRIs, Optical Biometry were implemented terrestrially for clinical monitoring. While no inflight vision testing was in place, already available onorbit technology was leveraged to facilitate in-flight clinical monitoring, including visual acuity, Amsler grid, tonometry, and ultrasonography. In 2013, on-orbit testing capabilities were expanded to include contrast sensitivity testing and OCT. As these additional testing capabilities have been added, resource prioritization, particularly crew time, is under evaluation.
Validity of the Worth 4 Dot Test in Patients with Red-Green Color Vision Defect.
Bak, Eunoo; Yang, Hee Kyung; Hwang, Jeong-Min
2017-05-01
The Worth four dot test uses red and green glasses for binocular dissociation, and although it has been believed that patients with red-green color vision defects cannot accurately perform the Worth four dot test, this has not been validated. Therefore, the purpose of this study was to demonstrate the validity of the Worth four dot test in patients with congenital red-green color vision defects who have normal or abnormal binocular vision. A retrospective review of medical records was performed on 30 consecutive congenital red-green color vision defect patients who underwent the Worth four dot test. The type of color vision anomaly was determined by the Hardy Rand and Rittler (HRR) pseudoisochromatic plate test, Ishihara color test, anomaloscope, and/or the 100 hue test. All patients underwent a complete ophthalmologic examination. Binocular sensory status was evaluated with the Worth four dot test and Randot stereotest. The results were interpreted according to the presence of strabismus or amblyopia. Among the 30 patients, 24 had normal visual acuity without strabismus nor amblyopia and 6 patients had strabismus and/or amblyopia. The 24 patients without strabismus nor amblyopia all showed binocular fusional responses by seeing four dots of the Worth four dot test. Meanwhile, the six patients with strabismus or amblyopia showed various results of fusion, suppression, and diplopia. Congenital red-green color vision defect patients of different types and variable degree of binocularity could successfully perform the Worth four dot test. They showed reliable results that were in accordance with their estimated binocular sensory status.
Vision Training Methods for Sports Concussion Mitigation and Management
Clark, Joseph F.; Colosimo, Angelo; Ellis, James K.; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon
2015-01-01
There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock’s string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention. PMID:25992878
Agnosic vision is like peripheral vision, which is limited by crowding.
Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa
2017-04-01
Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it urgent to know what drives crowding. Acuity does not (Song et al., 2014), but neural density might: neurons per deg 2 in the crowding-relevant cortical area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Temporary effects of alcohol on color vision
NASA Astrophysics Data System (ADS)
Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna
2017-09-01
The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col
Criteria for a State-of-the-Art Vision Test System
1985-05-01
tests are enumerated for possible inclusion in a battery of candidate vision tests to be statistically examined for validity as predictors of aircrew...derived subset thereof) of vision tests may be given to a series of individuals, and statistical tests may be used to determine which visual functions...no target. Statistical analysis of the responses would set a threshold level, which would define the smallest size - (most distant target) or least
Nau, Amy; Bach, Michael; Fisher, Christopher
2013-01-01
We evaluated whether existing ultra-low vision tests are suitable for measuring outcomes using sensory substitution. The BrainPort is a vision assist device coupling a live video feed with an electrotactile tongue display, allowing a user to gain information about their surroundings. We enrolled 30 adult subjects (age range 22-74) divided into two groups. Our blind group included 24 subjects ( n = 16 males and n = 8 females, average age 50) with light perception or worse vision. Our control group consisted of six subjects ( n = 3 males, n = 3 females, average age 43) with healthy ocular status. All subjects performed 11 computer-based psychophysical tests from three programs: Basic Assessment of Light Motion, Basic Assessment of Grating Acuity, and the Freiburg Vision Test as well as a modified Tangent Screen. Assessments were performed at baseline and again using the BrainPort after 15 hours of training. Most tests could be used with the BrainPort. Mean success scores increased for all of our tests except contrast sensitivity. Increases were statistically significant for tests of light perception (8.27 ± 3.95 SE), time resolution (61.4% ± 3.14 SE), light localization (44.57% ± 3.58 SE), grating orientation (70.27% ± 4.64 SE), and white Tumbling E on a black background (2.49 logMAR ± 0.39 SE). Motion tests were limited by BrainPort resolution. Tactile-based sensory substitution devices are amenable to psychophysical assessments of vision, even though traditional visual pathways are circumvented. This study is one of many that will need to be undertaken to achieve a common outcomes infrastructure for the field of artificial vision.
Validation of an inexpensive test illuminant for aeromedical color vision screening.
DOT National Transportation Integrated Search
1993-09-01
An inexpensive illuminant for color vision screening suggested by the NRC-NAS Committee on Vision was evaluated as a substitute for the Macbeth Easel Lamp. The Macbeth Easel Lamp is the recommended illuminant for pseudoisochromatic plate tests used i...
A vision for modernizing environmental risk assessment
In 2007, the US National Research Council (NRC) published a Vision and Strategy for [human health] Toxicity Testing in the 21st century. Central to the vision was increased reliance on high throughput in vitro testing and predictive approaches based on mechanistic understanding o...
... testing. AMSLER GRID TEST This test helps detect macular degeneration . This is a disease that causes blurred vision, ... exam. People who are at risk of developing macular degeneration may be told by their ophthalmologist to perform ...
Maini, Anuj Paul; Wangoo, Anuj; Singh, Sukhman; Mehar, Damanpreet Kaur
2017-01-01
Abstract Introduction The success of a restoration is dependent on accurate shade matching of teeth leading to studies evaluating the factors affecting the perception of shades. Colour vision anomalies including colour blindness have been found to exist in the population and it has been thought to be a potential factor affecting the colour perception ability. Aim The present study was done to evaluate the prevalence of colour vision anomalies and its effect on matching of shades of teeth. Materials and Methods A total of 147 dental professionals were randomly selected for the study and were first tested for visual acuity using the Snellen’s Eye Chart so as to carry on the study with only those operators who had a vision of 6/6. Then, the Ishihara’s colour charts were used to test the operators for colour vision handicap. In the last stage of the study, test for accuracy of shade selection was done using the Vitapan Classical shade guide. The shade guide tabs were covered to avoid bias. Percentage was used to calculate the prevalence of colour vision handicap and its effect on matching of shades of teeth as compared to normal vision, which was evaluated using Chi square test. Results Nineteen operators had colour vision anomalies out of hundred operators and only two operators presented with colour blindness. Colour vision anomaly was more prevalent than colour blindness and it was also found that it was more prevalent in males than females. The difference between the accuracy of shade matching between the operators with normal vision and colour vision defect and operators with normal vision and colour blindness was statistically not significant. Conclusion Colour blindness and colour vision handicap are rare conditions, with the latter being more common in the population. According to our study, it was concluded that no statistically significant difference existed amongst the operators with normal vision and colour vision anomaly or operators with normal vision and colour blindness during the matching of shades of teeth. PMID:28274040
Color vision in children and the Lanthony New Color Test.
Ling, Barbara Y; Dain, Stephen J
2008-01-01
Much is known about color vision in infants, adolescents, and adults, but very few studies report the changes, which occur in color perception of children in their early schooling years. There is also a shortage of suitable color vision tests for children. This study investigated the changes in color vision of school students between 5-12 years old using the Lanthony New Color Test (NCT). Subjects of all ages were able to complete a shortened form of this test adequately. The Vingrys and King-Smith (1988) method of panel test analysis and Adams and Rodic (1982) color confusion score were adapted to analyze their performance of the test. This study confirmed that there are changes in color perception occurring in this age group. Color perception abilities increased as a function of age and there was also an improvement in the performance on the NCT with age. This can be attributed to both cognitive development and changes occurring to the color vision system.
A Practical Solution Using A New Approach To Robot Vision
NASA Astrophysics Data System (ADS)
Hudson, David L.
1984-01-01
Up to now, robot vision systems have been designed to serve both application development and operational needs in inspection, assembly and material handling. This universal approach to robot vision is too costly for many practical applications. A new industrial vision system separates the function of application program development from on-line operation. A Vision Development System (VDS) is equipped with facilities designed to simplify and accelerate the application program development process. A complimentary but lower cost Target Application System (TASK) runs the application program developed with the VDS. This concept is presented in the context of an actual robot vision application that improves inspection and assembly for a manufacturer of electronic terminal keyboards. Applications developed with a VDS experience lower development cost when compared with conventional vision systems. Since the TASK processor is not burdened with development tools, it can be installed at a lower cost than comparable "universal" vision systems that are intended to be used for both development and on-line operation. The VDS/TASK approach opens more industrial applications to robot vision that previously were not practical because of the high cost of vision systems. Although robot vision is a new technology, it has been applied successfully to a variety of industrial needs in inspection, manufacturing, and material handling. New developments in robot vision technology are creating practical, cost effective solutions for a variety of industrial needs. A year or two ago, researchers and robot manufacturers interested in implementing a robot vision application could take one of two approaches. The first approach was to purchase all the necessary vision components from various sources. That meant buying an image processor from one company, a camera from another and lens and light sources from yet others. The user then had to assemble the pieces, and in most instances he had to write all of his own software to test, analyze and process the vision application. The second and most common approach was to contract with the vision equipment vendor for the development and installation of a turnkey inspection or manufacturing system. The robot user and his company paid a premium for their vision system in an effort to assure the success of the system. Since 1981, emphasis on robotics has skyrocketed. New groups have been formed in many manufacturing companies with the charter to learn about, test and initially apply new robot and automation technologies. Machine vision is one of new technologies being tested and applied. This focused interest has created a need for a robot vision system that makes it easy for manufacturing engineers to learn about, test, and implement a robot vision application. A newly developed vision system addresses those needs. Vision Development System (VDS) is a complete hardware and software product for the development and testing of robot vision applications. A complimentary, low cost Target Application System (TASK) runs the application program developed with the VDS. An actual robot vision application that demonstrates inspection and pre-assembly for keyboard manufacturing is used to illustrate the VDS/TASK approach.
Dain, Stephen J; Casolin, Armand; Long, Jennifer
2015-02-01
There are two currently available lantern tests that have their design based solely on the practices of the rail industry. These are the CN Lantern (CNLAN) used on the Canadian Railways and the Railway LED Lantern Tests (RLLT). In the same way that the signaling practices differ in the two jurisdictions, the design of the lanterns also differ. The CIE (Commission Internationale de l'Éclairage)-recommended color vision standards for transport predate both lanterns. The study was undertaken to assess the appropriateness of these lanterns in CIE Color Vision Standard 1. CIE Standard 1 is called "Normal color vision" but some very mild anomalous trichromats may pass the specified "lantern test that presents a high level of difficulty." The lantern tests were undertaken by 46 color vision-normal and 37 color vision-deficient subjects. Subjects made more errors on the RLLT, and the pattern of errors is different, partly because there are blank presentations in the RLLT and "no light" is an acceptable response. The two lanterns showed agreement on the pass/fail categorization of 73 of the 83 subjects. The RLLT fails more color vision-normal subjects. Despite the different construction principles, the RLLT and CNLAN have pass/fail levels that are comparable with the Holmes-Wright Type B lantern, which is nominated in CIE Color Vision Standard 1 but is no longer commercially available. The higher failure rate of color vision-normal subjects on the RLLT has been addressed by changing the intensities of the two darkest red lights.
Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M
2013-09-01
The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs. Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Pezzaniti, J. Larry; Edmondson, Richard; Vaden, Justin; Hyatt, Bryan; Chenault, David B.; Kingston, David; Geulen, Vanilynmae; Newell, Scott; Pettijohn, Brad
2009-02-01
In this paper, we report on the development of a 3D vision system consisting of a flat panel stereoscopic display and auto-converging stereo camera and an assessment of the system's use for robotic driving, manipulation, and surveillance operations. The 3D vision system was integrated onto a Talon Robot and Operator Control Unit (OCU) such that direct comparisons of the performance of a number of test subjects using 2D and 3D vision systems were possible. A number of representative scenarios were developed to determine which tasks benefited most from the added depth perception and to understand when the 3D vision system hindered understanding of the scene. Two tests were conducted at Fort Leonard Wood, MO with noncommissioned officers ranked Staff Sergeant and Sergeant First Class. The scenarios; the test planning, approach and protocols; the data analysis; and the resulting performance assessment of the 3D vision system are reported.
Testing the Untestable: A Vision Screening Program for Exceptional Children.
ERIC Educational Resources Information Center
Bishop, Virginia E.; Godolphin, Vivienne
Based on a longitudinal study of vision screening techniques for handicapped children at the Chester County (Pennsylvania) Child Development Center, the paper reports on the development of a battery of effective vision screening methods for children with low functioning handicapped children. Specific tests are described, including the Sheridan…
A Low Vision Reading Comprehension Test.
ERIC Educational Resources Information Center
Watson, G. R.; And Others
1996-01-01
Fifty adults (ages 28-86) with macular degeneration were given the Low Vision Reading Comprehension Assessment (LVRCA) to test its reliability and validity in evaluating the reading comprehension of those with vision impairments. The LVRCA was found to take only nine minutes to administer and was a valid and reliable tool. (CR)
Military Research ColorDx and Printed Color Vision Tests.
Almustanyir, Ali; Hovis, Jeffery K
2015-10-01
To determine the equivalence of the ColorDx Military Research version (mColorDx) test and three printed pseudoisochromatic tests (HRR, Ishihara, and PIPIC) for color vision testing. Participating in the study were 75 color-normals and 47 subjects with red-green color vision defects. Color vision was classified by an anomaloscope. The HRR (4(th) edition), Ishihara 38-plate edition, and PIPIC tests are printed color vision tests, whereas mColorDx test figures were displayed on a calibrated computer desktop monitor. All tests were repeated in about 1 wk. The kappa level of agreement (κ) values with the anomaloscope for screening for each test was 0.96 or greater. The values were statistically identical. Specificity for each test was at least 0.99 and sensitivity was at least 0.95. The repeatability of the screening sections for all tests was very good with κ values greater than 0.95. Deutans tended to miss the tritan screening plates on the HRR and mColorDx tests. The Spearman rank correlation coefficients between the severity of the defect and anomaloscope range was moderate with r = 0.45 for the mColorDx and r = 0.6 for the HRR. Both the mColorDx and HRR had perfect agreement with the anomaloscope in classifying the defects as either protan or deutan. The validity of the four tests for color vision screening was statistically identical; however, the HRR may be preferred because it had the highest sensitivity of 0.99, a specificity of 1.0, and a reasonable correlation between the severity rating of the defect and the anomaloscope range.
Flinkman, Mika; Nakauchi, Shigeki
2017-10-01
In this research, three illuminants that improve color discrimination ability of people with red-green color vision deficiency were developed. The illuminants are close to daylight-colored and were produced by using spectral optimization. Deutans were the focus of this research, but a few protans were also tested for reference. The illuminants were produced by combining different types of LEDs, and their effects were tested with several test subjects with and without color vision deficiency using the Ishihara color vision test and the Farnsworth Panel D-15 test. The illuminant with the most powerful effect provided near perfect results with the Ishihara test for deutans, while the other two illuminants produced smaller improvements. The Farnsworth Panel D-15 test produced results that were similar to the Ishihara test though generally the color discrimination of blue hues was weaker under the most powerful illuminant.
Disparities in access to medical care for individuals with vision impairment.
Spencer, Christine; Frick, Kevin; Gower, Emily W; Kempen, John H; Wolff, Jennifer L
2009-01-01
We investigated the relationship between blindness and vision impairment and access to medical care. Pooled data from the Medical Expenditure Panel Survey (MEPS) years 2002-2004 were used to identify non-institutionalized individuals over the age of 40 with either self-reported blindness, vision impairment, or no vision impairment (n = 40,643). Differences in access to care measures by vision status were assessed, after adjusting for the complex sampling design of the MEPS, using either two-sided z-tests or two-sided t-tests. Individuals with blindness and vision impairment report having more access problems related to cost of care, availability of insurance coverage, transportation issues, and refusal of services by providers, although they do not report lower rates of having a usual source of care compared to those without vision impairment. The results suggest that access to care for individuals with blindness and vision impairment is problematic, for reasons that are amenable to policy interventions.
A method for identifying color vision deficiency malingering.
Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo
2017-03-01
To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.
Accuracy of four commonly used color vision tests in the identification of cone disorders.
Thiadens, Alberta A H J; Hoyng, Carel B; Polling, Jan Roelof; Bernaerts-Biskop, Riet; van den Born, L Ingeborgh; Klaver, Caroline C W
2013-04-01
To determine which color vision test is most appropriate for the identification of cone disorders. In a clinic-based study, four commonly used color vision tests were compared between patients with cone dystrophy (n = 37), controls with normal visual acuity (n = 35), and controls with low vision (n = 39) and legal blindness (n = 11). Mean outcome measures were specificity, sensitivity, positive predictive value and discriminative accuracy of the Ishihara test, Hardy-Rand-Rittler (HRR) test, and the Lanthony and Farnsworth Panel D-15 tests. In the comparison between cone dystrophy and all controls, sensitivity, specificity and predictive value were highest for the HRR and Ishihara tests. When patients were compared to controls with normal vision, discriminative accuracy was highest for the HRR test (c-statistic for PD-axes 1, for T-axis 0.851). When compared to controls with poor vision, discriminative accuracy was again highest for the HRR test (c-statistic for PD-axes 0.900, for T-axis 0.766), followed by the Lanthony Panel D-15 test (c-statistic for PD-axes 0.880, for T-axis 0.500) and Ishihara test (c-statistic 0.886). Discriminative accuracies of all tests did not further decrease when patients were compared to controls who were legally blind. The HRR, Lanthony Panel D-15 and Ishihara all have a high discriminative accuracy to identify cone disorders, but the highest scores were for the HRR test. Poor visual acuity slightly decreased the accuracy of all tests. Our advice is to use the HRR test since this test also allows for evaluation of all three color axes and quantification of color defects.
Is vision function related to physical functional ability in older adults?
West, Catherine G; Gildengorin, Ginny; Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E; Lott, Lori; Brabyn, John A
2002-01-01
To assess the relationship between a broad range of vision functions and measures of physical performance in older adults. Cross-sectional study. Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study. Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95. Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance). The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes. Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.
Color vision deficiencies and the child's willingness for visual activity: preliminary research
NASA Astrophysics Data System (ADS)
Geniusz, Malwina; Szmigiel, Marta; Geniusz, Maciej
2017-09-01
After a few weeks a newborn baby can recognize high contrasts in colors like black and white. They reach full color vision at the age of circa six months. Matching colors is the next milestone. Most children can do it at the age of two. Good color vision is one of the factors which indicate proper development of a child. Presented research shows the correlation between color vision and visual activity. The color vision of a group of children aged 3-8 was examined with saturated Farnsworth D-15. Fransworth test was performed twice - in a standard version and in a magnetic version. The time of completing standard and magnetic tests was measured. Furthermore, parents of subjects answered questions checking the children's visual activity in 1 - 10 scale. Parents stated whether the child willingly watched books, colored coloring books, put puzzles or liked to play with blocks etc. The Fransworth D-15 test designed for color vision testing can be used to test younger children from the age of 3 years. These are preliminary studies which may be a useful tool for further, more accurate examination on a larger group of subjects.
Intensity measurement of automotive headlamps using a photometric vision system
NASA Astrophysics Data System (ADS)
Patel, Balvant; Cruz, Jose; Perry, David L.; Himebaugh, Frederic G.
1996-01-01
Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.
Ramaswamy, Shankaran; Hovis, Jeffery K
2004-01-01
Color codes in VDT displays often contain sets of colors that are confusing to individuals with color-vision deficiencies. The purpose of this study is to determine whether individuals with color-vision deficiencies (color defectives) can perform as well as individuals without color-vision deficiencies (color normals) on a colored VDT display used in the railway industry and to determine whether clinical color-vision tests can predict their performance. Of the 52 color defectives, 58% failed the VDT test. The kappa coefficients of agreement for the Farnsworth D-15, Adams desaturated D-15, and Richmond 3rd Edition HRR PIC diagnostic plates were significantly greater than chance. In particular, the D-15 tests have a high probability of predicting who fails the practical test. However, all three tests had an unacceptably high false-negative rate (9.5-35%); so that a practical test is still needed.
Color Vision Deficiencies in Children. United States.
ERIC Educational Resources Information Center
National Center for Health Statistics (DHEW/PHS), Hyattsville, MD.
Presented are prevalence data on color vision deficiencies (color blindness) in noninstitutionalized children, aged 6-11, in the United States, as estimated from the Health Examination Survey findings on a representative sample of over 7,400 children. Described are the two color vision tests used in the survey, the Ishihara Test for Color…
Stereoacuity of preschool children with and without vision disorders.
Ciner, Elise B; Ying, Gui-Shuang; Kulp, Marjean Taylor; Maguire, Maureen G; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Huang, Jiayan
2014-03-01
To evaluate associations between stereoacuity and presence, type, and severity of vision disorders in Head Start preschool children and determine testability and levels of stereoacuity by age in children without vision disorders. Stereoacuity of children aged 3 to 5 years (n = 2898) participating in the Vision in Preschoolers (VIP) Study was evaluated using the Stereo Smile II test during a comprehensive vision examination. This test uses a two-alternative forced-choice paradigm with four stereoacuity levels (480 to 60 seconds of arc). Children were classified by the presence (n = 871) or absence (n = 2027) of VIP Study-targeted vision disorders (amblyopia, strabismus, significant refractive error, or unexplained reduced visual acuity), including type and severity. Median stereoacuity between groups and among severity levels of vision disorders was compared using Wilcoxon rank sum and Kruskal-Wallis tests. Testability and stereoacuity levels were determined for children without VIP Study-targeted disorders overall and by age. Children with VIP Study-targeted vision disorders had significantly worse median stereoacuity than that of children without vision disorders (120 vs. 60 seconds of arc, p < 0.001). Children with the most severe vision disorders had worse stereoacuity than that of children with milder disorders (median 480 vs. 120 seconds of arc, p < 0.001). Among children without vision disorders, testability was 99.6% overall, increasing with age to 100% for 5-year-olds (p = 0.002). Most of the children without vision disorders (88%) had stereoacuity at the two best disparities (60 or 120 seconds of arc); the percentage increasing with age (82% for 3-, 89% for 4-, and 92% for 5-year-olds; p < 0.001). The presence of any VIP Study-targeted vision disorder was associated with significantly worse stereoacuity in preschool children. Severe vision disorders were more likely associated with poorer stereopsis than milder or no vision disorders. Testability was excellent at all ages. These results support the validity of the Stereo Smile II for assessing random-dot stereoacuity in preschool children.
Vision function testing for a suprachoroidal retinal prosthesis: effects of image filtering
NASA Astrophysics Data System (ADS)
Barnes, Nick; Scott, Adele F.; Lieby, Paulette; Petoe, Matthew A.; McCarthy, Chris; Stacey, Ashley; Ayton, Lauren N.; Sinclair, Nicholas C.; Shivdasani, Mohit N.; Lovell, Nigel H.; McDermott, Hugh J.; Walker, Janine G.; BVA Consortium,the
2016-06-01
Objective. One strategy to improve the effectiveness of prosthetic vision devices is to process incoming images to ensure that key information can be perceived by the user. This paper presents the first comprehensive results of vision function testing for a suprachoroidal retinal prosthetic device utilizing of 20 stimulating electrodes. Further, we investigate whether using image filtering can improve results on a light localization task for implanted participants compared to minimal vision processing. No controlled implanted participant studies have yet investigated whether vision processing methods that are not task-specific can lead to improved results. Approach. Three participants with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal retinal prosthesis. All three completed multiple trials of a light localization test, and one participant completed multiple trials of acuity tests. The visual representations used were: Lanczos2 (a high quality Nyquist bandlimited downsampling filter); minimal vision processing (MVP); wide view regional averaging filtering (WV); scrambled; and, system off. Main results. Using Lanczos2, all three participants successfully completed a light localization task and obtained a significantly higher percentage of correct responses than using MVP (p≤slant 0.025) or with system off (p\\lt 0.0001). Further, in a preliminary result using Lanczos2, one participant successfully completed grating acuity and Landolt C tasks, and showed significantly better performance (p=0.004) compared to WV, scrambled and system off on the grating acuity task. Significance. Participants successfully completed vision tasks using a 20 electrode suprachoroidal retinal prosthesis. Vision processing with a Nyquist bandlimited image filter has shown an advantage for a light localization task. This result suggests that this and targeted, more advanced vision processing schemes may become important components of retinal prostheses to enhance performance. ClinicalTrials.gov Identifier: NCT01603576.
Student performance and appreciation using 3D vs. 2D vision in a virtual learning environment.
de Boer, I R; Wesselink, P R; Vervoorn, J M
2016-08-01
The aim of this study was to investigate the differences in the performance and appreciation of students working in a virtual learning environment with two (2D)- or three (3D)-dimensional vision. One hundred and twenty-four randomly divided first-year dental students performed a manual dexterity exercise on the Simodont dental trainer with an automatic assessment. Group 1 practised in 2D vision and Group 2 in 3D. All of the students practised five times for 45 min and then took a test using the vision they had practised in. After test 1, all of the students switched the type of vision to control for the learning curve: Group 1 practised in 3D and took a test in 3D, whilst Group 2 practised in 2D and took the test in 2D. To pass, three of five exercises had to be successfully completed within a time limit. The students filled out a questionnaire after completing test 2. The results show that students working with 3D vision achieved significantly better results than students who worked in 2D. Ninety-five per cent of the students filled out the questionnaire, and over 90 per cent preferred 3D vision. The use of 3D vision in a virtual learning environment has a significant positive effect on the performance of the students as well as on their appreciation of the environment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vision in laboratory rodents-Tools to measure it and implications for behavioral research.
Leinonen, Henri; Tanila, Heikki
2017-07-29
Mice and rats are nocturnal mammals and their vision is specialized for detection of motion and contrast in dim light conditions. These species possess a large proportion of UV-sensitive cones in their retinas and the majority of their optic nerve axons target superior colliculus rather than visual cortex. Therefore, it was a widely held belief that laboratory rodents hardly utilize vision during day-time behavior. This dogma is being questioned as accumulating evidence suggests that laboratory rodents are able to perform complex visual functions, such as perceiving subjective contours, and that declined vision may affect their performance in many behavioral tasks. For instance, genetic engineering may have unexpected consequences on vision as mouse models of Alzheimer's and Huntington's diseases have declined visual function. Rodent vision can be tested in numerous ways using operant training or reflex-based behavioral tasks, or alternatively using electrophysiological recordings. In this article, we will first provide a summary of visual system and explain its characteristics unique to rodents. Then, we present well-established techniques to test rodent vision, with an emphasis on pattern vision: visual water test, optomotor reflex test, pattern electroretinography and pattern visual evoked potentials. Finally, we highlight the importance of visual phenotyping in rodents. As the number of genetically engineered rodent models and volume of behavioral testing increase simultaneously, the possibility of visual dysfunctions needs to be addressed. Neglect in this matter potentially leads to crude biases in the field of neuroscience and beyond. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Stetson, Suzanne; Weber, Hadley; Crosby, Frank J.; Tinsley, Kenneth; Kloess, Edmund; Nevis, Andrew J.; Holloway, John H., Jr.; Witherspoon, Ned H.
2004-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) project has developed and tested a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). The Coastal System Station"s ALRT project, under funding from the Office of Naval Research (ONR), has been designing, developing, integrating, and testing commercial arrays using a Cessna airborne platform over the last several years. This has led to the development of the Airborne Laser Diode Array Illuminator wide field-of-view (ALDAI-W) imaging test bed system. The ALRT project tested ALDAI-W at the Army"s Night Vision Lab"s Airborne Mine Detection Arid Test. By participating in Night Vision"s test, ALRT was able to collect initial prototype nighttime operational data using ALDAI-W, showing impressive results and pioneering the way for final test bed demonstration conducted in September 2003. This paper describes the ALDAI-W Arid Test and results, along with processing steps used to generate imagery.
Smartphone serious games for vision and hearing assessment.
Dias, Pedro; Aguiar, Bruno; Sousa, Filipe; Sousa, Augusto
2015-01-01
Falls are the second leading cause of accidental injury deaths worldwide. In this paper, it is intended to define methodologies that permit the evaluation of two potential factors which might have an impact on fall risk, these are: visual and hearing loss. The aim of the work developed is not to replace clinic visits, but to offer the user the means to continue the tracking of his vision and hearing at home, during the long time intervals between clinical tests. Tests conducted in a sample of our target users indicate a good ability to measure vision and hearing using an android smartphone and the proposed methodologies. While some tests require further validation, promising results were achieved in the most common tests for vision and hearing, presenting a good correlation between the system's results when compared to the traditional tests (for distance visual acuity) and the data gathered from the users (for hearing tests).
Bhorade, Anjali M.; Perlmutter, Monica S.; Wilson, Brad; Kambarian, Jamie; Chang, Sidney; Pekmezci, Melike; Gordon, Mae
2015-01-01
Importance Patients often report greater visual difficulties at home than expected from vision testing in the clinic. Such discordance may be due to worse vision in the home than measured in clinic. Objective To compare vision measured between clinic and home and evaluate factors, including lighting, associated with these differences. Design Cross-sectional, between years 2005–2009. Setting Participants recruited from the Glaucoma and Comprehensive Eye Clinics at Washington University, St. Louis, MO underwent a clinic and home visit. Participants 126 glaucoma and 49 non-glaucoma patients, ages 55–90 years, consecutively recruited and met inclusion criteria for this report; 166 eligible patients refused participation. Exposure Participants underwent a clinic and home visit randomized to order of completion. At each visit, masked and certified examiners measured binocular distance visual acuity (DVA) with a non-backlit chart, near visual acuity (NVA), contrast sensitivity (CS), CS with glare, and lighting. Main Outcome Measure Differences in vision between clinic and home. Results Mean scores for all vision tests were significantly better in the clinic than home for glaucoma and non-glaucoma patients (p<0.05, matched pair t-tests). For DVA, 29% of glaucoma participants read ≥2 lines better in clinic than home and 39% with advanced glaucoma read ≥3 lines better. For the entire sample, 21% of participants read ≥2 lines better in clinic than home for NVA and 49% read ≥2 triplets better in clinic for CS with glare. Lighting was the most significant factor associated with differences in vision between clinic and home for DVA, NVA, and CS with glare testing (p<0.05 multiple regression model). Median home lighting was 4.3 times and 2.8 times lower than clinic lighting in areas tested for DVA and NVA, respectively. Home lighting was below that recommended in ≥ 85% of participants. Conclusions and Relevance Vision measured in the clinic is generally better than vision measured at home, with differences mainly due to poor home lighting. Knowledge that vision discrepancies between patient report and clinical testing may be due to home lighting may initiate clinician-patient discussions to increase home lighting and improve vision of older adults in their homes. PMID:24263699
Functional Defects in Color Vision in Patients With Choroideremia.
Jolly, Jasleen K; Groppe, Markus; Birks, Jacqueline; Downes, Susan M; MacLaren, Robert E
2015-10-01
To characterize defects in color vision in patients with choroideremia. Prospective cohort study. Thirty patients with choroideremia (41 eyes) and 10 age-matched male controls (19 eyes) with visual acuity of ≥6/36 attending outpatient clinics in Oxford Eye Hospital underwent color vision testing with the Farnsworth-Munsell 100 hue test, visual acuity testing, and autofluorescence imaging. To exclude changes caused by degeneration of the fovea, a subgroup of 14 patients with a visual acuity ≥6/6 was analyzed. Calculated color vision total error scores were compared between the groups and related to a range of factors using a random-effects model. Mean color vision total error scores were 120 (95% confidence interval [CI] 92, 156) in the ≥6/6 choroideremia group, 206 (95% CI 161, 266) in the <6/6 visual acuity choroideremia group, and 47 (95% CI 32, 69) in the control group. Covariate analysis showed a significant difference in color vision total error score between the groups (P < .001 between each group). Patients with choroideremia have a functional defect in color vision compared with age-matched controls. The color vision defect deteriorates as the degeneration encroaches on the fovea. The presence of an early functional defect in color vision provides a useful biomarker against which to assess successful gene transfer in gene therapy trials. Copyright © 2015 Elsevier Inc. All rights reserved.
Occupational colour vision requirements for police officers.
Birch, Jennifer; Chisholm, Catharine M
2008-11-01
Inclusion of public service professions in the UK Disability Discrimination Act in 2004 prompted a review of occupational colour vision requirements for police officers. Changes in the regulations which existed prior to 2003 were proposed. The aim of this study was to obtain the views of serving police officers in Northern Ireland on the importance of good colour discrimination in everyday police work and on the recruitment regulations for patrol constables introduced in 2003 in mainland UK. These views were obtained by means of a questionnaire and informal discussions. More than 65% of police officers who responded to the questionnaire considered that good colour vision was very important for effective policing. Fewer than 2% considered that colour vision was unimportant. Experienced police officers agreed that the employment of colour-deficient patrol constables, as permitted in the new regulations, would lead to reduced efficiency and organisational difficulties at the local level. A number of everyday activities were described which showed the need for accurate colour discrimination. The change in recruitment policy and the lack of clarity in the new regulations show inadequate appreciation of the needs of the occupation, of different types of colour vision anomalies and of the diagnostic function of colour vision tests. Failure to provide guidance on appropriate colour vision tests, examination procedures and counselling services is likely to result in inconsistent employment policies in different police forces. It is recommended that the colour vision standard in place prior to 2003 is reinstated at the recruitment stage. The Ishihara test should be used for screening, and colour-deficient applicants further examined with the Farnsworth D15 test as a replacement for the City University Test 2nd edition.
ERIC Educational Resources Information Center
Reardon, A. W.; And Others
1993-01-01
Instructional materials on hypoglycemia, foot care, and exercise were developed and field tested with 98 diabetes patients who had low vision and/or low literacy. A pretest and posttest revealed an 81% reduction in wrong answers overall and a 72% reduction in wrong answers by a subset with low vision. (Author/DB)
2014-06-03
ISS040-E-006739 (3 June 2014) --- European Space Agency astronaut Alexander Gerst, Expedition 40 flight engineer, uses the Optical Coherence Tomography (OCT) camera during an Ocular Health (OH) vision test in the Harmony node of the International Space Station. The OH experiment observes and seeks to understand vision changes during long-term space missions. NASA astronaut Steve Swanson (left), Expedition 40 commander, assists Gerst.
Operational Assessment of Color Vision
2016-06-20
evaluated in this study. 15. SUBJECT TERMS Color vision, aviation, cone contrast test, Colour Assessment & Diagnosis , color Dx, OBVA 16. SECURITY...symbologies are frequently used to aid or direct critical activities such as aircraft landing approaches or railroad right-of-way designations...computer-generated display systems have facilitated the development of computer-based, automated tests of color vision [14,15]. The United Kingdom’s
Hypoxia, color vision deficiencies, and blood oxygen saturation.
Hovis, Jeffery K; Milburn, Nelda J; Nesthus, Thomas E
2012-02-01
Chromatic thresholds were measured using the Cambridge Colour Test (CCT), the Colour Assessment and Diagnosis (CAD) test, and the Cone Specific Contrast Test (CSCT) at ground and 3780 m (12,400 ft) for subjects with normal color vision and red-green color vision defects. The CAD revealed a small (~10%) increase in the red-green thresholds for the trichromatic subjects and a similar increase in the blue-yellow thresholds for the dichromats. The other two color vision tests did not reveal any significant change in chromatic thresholds. The CAD results for the trichromats were consistent with a rotation of the discrimination ellipse counterclockwise with little change in the elliptical area. This alteration in the color discrimination ellipse can occur when retinal illumination is lowered. © 2012 Optical Society of America
Vision Screening For Head Starters.
ERIC Educational Resources Information Center
Foley, Celia
To determine which children in the Head Start program may have vision problems, Head Start teachers and staff do vision "screening." This booklet demonstrates how to do the screening using the Snellen "E Chart." Trouble signs that the test administrator should be aware of are listed, and vision scores are explained simply.…
[Investigation of Color Vision Using Pigment Color Plates and a Tablet PC].
Tsimpri, P; Kuchenbecker, J
2016-07-01
Many applications (apps) for ophthalmic solutions, including colour vision tests, are currently available. However, no colour vision test app has been evaluated through clinical trials on a tablet PC. Using standard test conditions and a tablet pc (iPad2®), colour vision tests were performed with 19 Velhagen/Broschmann/Kuchenbecker colour plates and an HMC anomaloscope. The plates were alternately presented at first in a book (pigment colour plates) and then in a tablet PC (iPad®). A total of 77 volunteer subjects were examined. 62 subjects were colour normal and 15 male subjects had a colour vision deficiency. The coincidence and the 95 % confidence intervals were determined. The average age of all subjects (n = 77) was 42.8 ± 16.9 years. The mean near visual acuity of all subjects was 0.99 ± 0.15. The coincidence of the results of all subjects between books and tablet PC was 88.0 %. The 95 % confidence interval ranged from 81.6 to 89.6 %. In the group of subjects with colour vision deficiency (n = 15), the coincidence was 83.3 %. The 95 % confidence interval ranged from 78.4 to 87.3 %. In the group of subjects without colour vision deficiency (n = 62), the coincidence was 89.1 %. The 95 % confidence interval ranged from 87.1 to 90.8 %. The overlap of error numbers of colour normal subjects and colour vision deficiency subjects was 2 errors with the book and 5 errors with the tablet pc. Testing colour vision using book and tablet pc only gives roughly comparable results. However, separation with the book was better and the colour plates differed in validity. For this reason, only some of the colour plates could be used on a tablet PC. Georg Thieme Verlag KG Stuttgart · New York.
Color Vision Deficiency in Preschool Children
Xie, John Z.; Tarczy-Hornoch, Kristina; Lin, Jesse; Cotter, Susan A.; Torres, Mina; Varma, Rohit
2016-01-01
Purpose To determine the sex- and ethnicity-specific prevalence of color vision deficiency (CVD) in black, Asian, Hispanic, and non-Hispanic white preschool children. Design Population-based, cross-sectional study. Participants The Multi-Ethnic Pediatric Eye Disease Study is a population-based evaluation of the prevalence of vision disorders in children in Southern California. A total of 5960 subjects 30 to 72 months of age were recruited for the study, of whom 4177 were able to complete color vision testing (1265 black, 812 Asian, 1280 Hispanic, and 820 non-Hispanic white). Methods Color vision testing was performed using Color Vision Testing Made Easy color plates (Home Vision Care, Gulf Breeze, FL), and diagnostic confirmatory testing was performed using the Waggoner HRR Diagnostic Test color plates (Home Vision Care). Main Outcome Measures Testability of color vision in preschool children between 30 and 72 months of age and prevalence of CVD stratified by age, sex, and ethnicity. Results Testability was 17% in children younger than 37 months of age, increasing to 57% in children 37 to 48 months of age, 89% in children 49 to 60 months of age, and 98% in children 61 to 72 months of age. The prevalence of CVD among boys was 1.4% for black, 3.1% for Asian, 2.6% for Hispanic, and 5.6% for non-Hispanic white children; the prevalence in girls was 0.0% to 0.5% for all ethnicities. The ethnic difference in CVD was statistically significant between black and non-Hispanic white children (P = 0.0003) and between Hispanic and non-Hispanic white children (P = 0.02). In boys, most CVD cases were either deutan (51%) or protan (34%); 32% were classified as mild, 15% as moderate, and 41% as severe. Conclusions Testability for CVD in preschool children is high by 4 years of age. The prevalence of CVD in preschool boys varies by ethnicity, with the highest prevalence in non-Hispanic white and lowest in black children. PMID:24702753
1954-01-01
THE AMERICAN OPTICAL VISION TESTER AND THE ARMED FORCES FAR VISUAL ACUITY TEST Comparisons were made of the visual acuity scores of 100 enlisted men on ...the American Optical Vision Tester (with Sloan plates) and on the Armed Forces Far Visual Acuity test. Order of presentation was: AO-left eye, AO...right eye, AFFVAT-left, AFVTAT-right. Correlation coefficients between AO and AFFVAT were around .89. Dispersion of acuity scores was about the same on
... 3½, kids should have eye health screenings and visual acuity tests (tests that measure sharpness of vision) ... eye rubbing extreme light sensitivity poor focusing poor visual tracking (following an object) abnormal alignment or movement ...
ERIC Educational Resources Information Center
Trief, E.; Morse, A. R.
1988-01-01
Strabismus and amblyopia are two common childhood vision conditions requiring early identification and treatment. Screening devices include external examination of the eye, ability to track, a cover test, acuity tests, and stereoscopic tests. Treatment includes patching therapy, use of glasses, orthoptics, CAM vision stimulator, or a combination…
An automated miniaturized Haploscope for testing binocular visual function
NASA Technical Reports Server (NTRS)
Decker, T. A.; Williams, R. E.; Kuether, C. L.; Wyman-Cornsweet, D.
1976-01-01
A computer-controlled binocular vision testing device has been developed as one part of a system designed for NASA to test the vision of astronauts during spaceflight. The device, called the Mark III Haploscope, utilizes semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phorias, fixation disparity and accommodation/convergence relationships. All tests are self-administered, yield quantitative data and may be used repeatedly without subject memorization. Future applications of this programmable, compact device include its use as a clinical instrument to perform routine eye examinations or vision screening, and as a research tool to examine the effects of environment or work-cycle upon visual function.
Evaluation of Next-Generation Vision Testers for Aeromedical Certification of Aviation Personnel
2009-07-01
measure distant, intermediate, and near acuity. The slides are essentially abbreviated versions of the Early Treatment for Diabetic Retinopathy Study...over, requiring intermediate vision testing and 12 were color deficient. Analysis was designed to detect statistically significant differences between...Vertical Phoria (Right & Left Hyperphoria) Test scores from each of the vision testers were collated and analyzed. Analysis was designed to detect
Six years of vision screening tests in pre-school children in kindergartens of Wroclaw
NASA Astrophysics Data System (ADS)
Szmigiel, Marta; Geniusz, Malwina; Szmigiel, Ireneusz
2017-09-01
Detection of vision defects of a child without professional knowledge is not easy. Very often, the parents of a small child does not know that their child sees incorrect. Also the youngster, not knowing any other way of seeing, does not know that it is not the best. While the vision of a small child is not yet fully formed, it is worth checking them very early. Defects detected early gives opportunity for the correction of anomalies, which might give the effect of the normal development of vision. According to the indications, the American Optometric Association (AOA) control eye examination should be performed between the ages of 6 months to 3 years, before going to school and then every two years. Members of SPIE Student Chapter, in cooperation with the Visual Optics Group working on the Department of Optics and Photonics (Faculty of Fundamental Problems, Wroclaw University of Science and Technology) for 6 years offer selected kindergartens of Wroclaw participation in project "Screening vision tests in pre-school children". Depending on the number of involved members of the student chapter and willing to cooperate students of Ophthalmology and Optometry, vision screening test was carried out in up to eight kindergartens every year. The basic purpose of screening vision test is to detect visual defects to start the correction so early in life as possible, while increasing the efficiency of the child's visual potential. The surrounding community is in fact more than enough examples of late diagnose vision problems, which resulted in lack of opportunity or treatment failure
Toothguide Trainer tests with color vision deficiency simulation monitor.
Borbély, Judit; Varsányi, Balázs; Fejérdy, Pál; Hermann, Péter; Jakstat, Holger A
2010-01-01
The aim of this study was to evaluate whether simulated severe red and green color vision deficiency (CVD) influenced color matching results and to investigate whether training with Toothguide Trainer (TT) computer program enabled better color matching results. A total of 31 color normal dental students participated in the study. Every participant had to pass the Ishihara Test. Participants with a red/green color vision deficiency were excluded. A lecture on tooth color matching was given, and individual training with TT was performed. To measure the individual tooth color matching results in normal and color deficient display modes, the TT final exam was displayed on a calibrated monitor that served as a hardware-based method of simulating protanopy and deuteranopy. Data from the TT final exams were collected in normal and in severe red and green CVD-simulating monitor display modes. Color difference values for each participant in each display mode were computed (∑ΔE(ab)(*)), and the respective means and standard deviations were calculated. The Student's t-test was used in statistical evaluation. Participants made larger ΔE(ab)(*) errors in severe color vision deficient display modes than in the normal monitor mode. TT tests showed significant (p<0.05) difference in the tooth color matching results of severe green color vision deficiency simulation mode compared to normal vision mode. Students' shade matching results were significantly better after training (p=0.009). Computer-simulated severe color vision deficiency mode resulted in significantly worse color matching quality compared to normal color vision mode. Toothguide Trainer computer program improved color matching results. Copyright © 2010 Elsevier Ltd. All rights reserved.
Comparison of Ishihara Booklet with Color Vision Smartphone Applications.
Sorkin, Nir; Rosenblatt, Amir; Cohen, Eyal; Ohana, Oded; Stolovitch, Chaim; Dotan, Gad
2016-07-01
To compare the standard Ishihara booklet with color-vision-testing smartphone applications. A prospective observational diagnostic study on 42 normal trichromats and 38 color-deficient subjects. Patients were presented with three color vision tests in random order: an Ishihara test booklet and two color-vision-testing smartphone applications: Eye2Phone and the Color Vision Test application (CVT app). Sensitivity and specificity of the electronic tests was compared with Ishihara results, and in each one of these applications every plate was individually analyzed for success/failure rate. Average age was 42.7 ± 12.9 years. There were 57 males (71.2%). Sensitivity and specificity of each test was 100% (38/38) and 95.2% (40/42) for the Eye2Phone, and 100% (38/38) and 54.8% (23/42) for the CVT app. There was no significant difference between the Ishihara booklet and the Eye2Phone (p = 0.500), with a high kappa measure of agreement (0.950, p < 0.001). The CVT app was significantly different than both other tests (p < 0.001) with a low kappa measure of agreement (0.535 with the Ishihara and 0.575 with the Eye2Phone). Of the 21 tested plates, color-deficient subjects failed 11.8 ± 3.1 plates in the Ishihara booklet and 14.1 ± 2.1 plates in the Eye2Phone (p < 0.001). Significant plate-specific differences for the color-deficient group were found in plate numbers 3, 6, 7, 8, 9, 15, and 16. Both tests were poorly able to give an indication of the specific dichromatism type. The Ishihara booklet was rated more comfortable and clearer than the Eye2Phone in color-deficient subjects. The CVT app was rated lowest for comfort and clarity in both groups. Smartphone applications testing for color vision deficiency are readily available; however, users of these apps should be aware that some may have different sensitivity for detection of color vision deficiency compared to Ishihara booklet, limiting their usefulness for clinical use. Therefore, further validation of these applications is required.
16 CFR 1203.12 - Test requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARD FOR BICYCLE HELMETS The Standard § 1203.12 Test requirements. (a) Peripheral vision. All bicycle helmets shall allow unobstructed vision through a minimum of 105° to the left and right sides of the...
16 CFR 1203.12 - Test requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARD FOR BICYCLE HELMETS The Standard § 1203.12 Test requirements. (a) Peripheral vision. All bicycle helmets shall allow unobstructed vision through a minimum of 105° to the left and right sides of the...
Evaluation of the stereo optical OPTEC(R)5000 for aeromedical color vision screening.
DOT National Transportation Integrated Search
2013-08-01
Screening tests are valued for their ability to detect the presence (test sensitivity) and the absence (test specificity) of a disease or a specific condition such as color vision deficiencies(CVDs). From an aviation safety standpoint, it is importan...
DOT National Transportation Integrated Search
1995-04-01
Two practical color vision tests were developed and validated for use in screening Air Traffic Control specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulat...
Validity of FAA-approved color vision tests for class II and class III aeromedical screening.
DOT National Transportation Integrated Search
1993-09-01
All clinical color vision tests currently used in the medical examination of pilots were studied regarding validity for prediction of performance on practical tests of ability to discriminate the aviation signal colors, red, green, and white given un...
Clinical vision characteristics of the congenital achromatopsias. II. Color vision.
Haegerstrom-Portnoy, G; Schneck, M E; Verdon, W A; Hewlett, S E
1996-07-01
Twelve X-linked (XL) achromats and 43 autosomal recessive (AR) achromats were tested using the Farnsworth D-15, Nagel anomaloscope, Sloan achromatopsia test, and Berson test using standard procedures. All of the tests identify achromatopsia, but very few differentially diagnose the various types. AR achromats were subclassified as complete (rods only) or incomplete (residual cone function present) by additional psychophysical testing. Complete and incomplete ARs do not perform differently on any clinical color vision measure, indicating that (1) rods predominantly mediate vision in both groups and (2) these tests are not useful for distinguishing between the groups. Both groups show considerable interindividual variation on all measures. Only one of the measures, the Berson test, designed to distinguish XLs from ARs, does so reliably. XLs and ARs do not differ significantly on the Nagel anomaloscope or most of the Sloan plates. The confusion angles of the D-15 do differ for the two groups, but the variability in each group makes the measure unreliable for classifying individuals. The Berson test is recommended to distinguish the XL from AR achromats.
Mertens, H W; Milburn, N J; Collins, W E
2000-12-01
Two practical color vision tests were developed and validated for use in screening Air Traffic Control Specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulation of color-coded materials from the most demanding, safety-critical color task performed in each type of facility. The tests were evaluated using 106 subjects with normal color vision and 85 with color vision deficiency. The en route center test, named the Flight Progress Strips Test (FPST), required the identification of critical red/black coding in computer printing and handwriting on flight progress strips. The terminal option test, named the Aviation Lights Test (ALT), simulated red/green/white aircraft lights that must be identified in night ATC tower operations. Color-coding is a non-redundant source of safety-critical information in both tasks. The FPST was validated by direct comparison of responses to strip reproductions with responses to the original flight progress strips and a set of strips selected independently. Validity was high; Kappa = 0.91 with original strips as the validation criterion and 0.86 with different strips. The light point stimuli of the ALT were validated physically with a spectroradiometer. The reliabilities of the FPST and ALT were estimated with Chronbach's alpha as 0.93 and 0.98, respectively. The high job-relevance, validity, and reliability of these tests increases the effectiveness and fairness of ATCS color vision testing.
Color vision impairment in type 2 diabetes assessed by the D-15d test and the Cambridge Colour Test.
Feitosa-Santana, Claudia; Paramei, Galina V; Nishi, Mauro; Gualtieri, Mirella; Costa, Marcelo F; Ventura, Dora F
2010-09-01
Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.
Relationship between writing skills and visual-motor control in low-vision students.
Atasavun Uysal, Songül; Aki, Esra
2012-08-01
The purpose of this study was to investigate the relationship between handwriting skills and visual motor control among students with low vision and to compare this with the performance of their normal sighted peers. 42 students with low vision and 26 normal sighted peers participated. The Bruininks-Oseretsky Motor Proficiency Test-Short Form (BOTMP-SF), Jebsen Taylor Hand Function Test's writing subtest, and a legibility assessment were administered. Significant differences were found between groups for students' writing speed, legibility, and visual motor control. Visual motor control was correlated both writing speed and legibility. Students with low vision had poorer handwriting performance, with lower legibility and slower writing speed. Writing performance time was related to visual motor control in students with low vision.
The reliability of a VISION COACH task as a measure of psychomotor skills.
Xi, Yubin; Rosopa, Patrick J; Mossey, Mary; Crisler, Matthew C; Drouin, Nathalie; Kopera, Kevin; Brooks, Johnell O
2014-10-01
The VISION COACH™ interactive light board is designed to test and enhance participants' psychomotor skills. The primary goal of this study was to examine the test-retest reliability of the Full Field 120 VISION COACH task. One hundred eleven male and 131 female adult participants completed six trials where they responded to 120 randomly distributed lights displayed on the VISION COACH interactive light board. The mean time required for a participant to complete a trial was 101 seconds. Intraclass correlation coefficients, ranging from 0.962 to 0.987 suggest the VISION COACH Full Field 120 task was a reliable task. Cohen's d's of adjacent pairs of trials suggest learning effects did not negatively affect reliability after the third trial.
Operational Based Vision Assessment Cone Contrast Test: Description and Operation
2016-06-02
Jun 2016. Report contains color . 14. ABSTRACT The work detailed in this report was conducted by the Operational Based Vision Assessment (OBVA...currently used by the Air Force for aircrew color vision screening. The new OBVA CCT is differentiated from the Rabin device primarily by hardware...test procedures, and analysis techniques. Like the Rabin CCT, the OBVA CCT uses colors that selectively stimulate the cone photoreceptors of the
Cognitive abilities of children on a gray seriation test.
Dain, Stephen J; Ling, Barbara Y
2009-06-01
The importance of testing children's color vision, particularly to identify color vision deficiencies at an early age, has long been agreed on by teachers and color vision researchers and healthcare workers. The classic color vision tests were not necessarily developed for children's cognitive abilities, even though they are commonly used to assess children's color vision. Although, in the past, psychologists have studied color seriation abilities of children, they have not necessarily chosen isoluminous stimuli, which would minimize brightness cues. This investigation was designed to assess the ability of children to seriate a gray series. Tests were constructed in the form of the Farnsworth-Munsell style of arrangement test with constant intervals of metric lightness (CIE L*). Four intervals (DeltaL* = 15, 10, 5, and 3) were used. The child was instructed to arrange the colors from darker to lighter (or vice versa). Errors were not made on the DeltaL* = 15 series. Only isolated errors were made on the DeltaL* = 10 series. Errors were made on the DeltaL* = 5 series that diminished with age to nil in the older groups. Errors were made on the DeltaL* = 3 series at all ages studied, which also diminished with increasing age. Children aged 5 to 12 have sufficiently grasped the concept of seriation. They are able to complete a series with DeltaL* = 5, hence are capable of performing color arrangement tests with similar color differences such as the Lanthony New Color Test and the Farnsworth-Munsell D-15. Given the large number of errors made on DeltaL* = 3 series, it may be concluded that children's performance on the 100-hue test, at least to the age of 12 years, could be unduly influenced by non-color vision factors.
Kuchenbecker, J; Blum, M; Paul, F
2016-03-01
In acute unilateral optic neuritis (ON) color vision defects combined with a decrease in visual acuity and contrast sensitivity frequently occur. This study investigated whether a web-based color vision test is a reliable detector of acquired color vision defects in ON and, if so, which charts are particularly suitable. In 12 patients with acute unilateral ON, a web-based color vision test ( www.farbsehtest.de ) with 25 color plates (16 Velhagen/Broschmann and 9 Ishihara color plates) was performed. For each patient the affected eye was tested first and then the unaffected eye. The mean best-corrected distance visual acuity (BCDVA) in the ON eye was 0.36 ± 0.20 and 1.0 ± 0.1 in the contralateral eye. The number of incorrectly read plates correlated with the visual acuity. For the ON eye a total of 134 plates were correctly identified and 166 plates were incorrectly identified, while for the disease-free fellow eye, 276 plates were correctly identified and 24 plates were incorrectly identified. Both of the blue/yellow plates were identified correctly 14 times and incorrectly 10 times using the ON eye and exclusively correctly (24 times) using the fellow eye. The Velhagen/Broschmann plates were incorrectly identified significantly more frequently in comparison with the Ishihara plates. In 4 out of 16 Velhagen/Broschmann plates and 5 out of 9 Ishihara plates, no statistically significant differences between the ON eye and the fellow eye could be detected. The number of incorrectly identified plates correlated with a decrease in visual acuity. Red/green and blue/yellow plates were incorrectly identified significantly more frequently with the ON eye, while the Velhagen/Broschmann color plates were incorrectly identified significantly more frequently than the Ishihara color plates. Thus, under defined test conditions the web-based color vision test can also be used to detect acquired color vision defects, such as those caused by ON. Optimization of the test by altering the combination of plates may be a useful next step.
Functional vision loss: a diagnosis of exclusion.
Villegas, Rex B; Ilsen, Pauline F
2007-10-01
Most cases of visual acuity or visual field loss can be attributed to ocular pathology or ocular manifestations of systemic pathology. They can also occasionally be attributed to nonpathologic processes or malingering. Functional vision loss is any decrease in vision the origin of which cannot be attributed to a pathologic or structural abnormality. Two cases of functional vision loss are described. In the first, a 58-year-old man presented for a baseline eye examination for enrollment in a vision rehabilitation program. He reported bilateral blindness since a motor vehicle accident with head trauma 4 years prior. Entering visual acuity was "no light perception" in each eye. Ocular health examination was normal and the patient made frequent eye contact with the examiners. He was referred for neuroimaging and electrophysiologic testing. The second case was a 49-year-old man who presented with a long history of intermittent monocular diplopia. His medical history was significant for psycho-medical evaluations and a diagnosis of factitious disorder. Entering uncorrected visual acuities were 20/20 in each eye, but visual field testing found constriction. No abnormalities were found that could account for the monocular diplopia or visual field deficit. A diagnosis of functional vision loss secondary to factitious disorder was made. Functional vision loss is a diagnosis of exclusion. In the event of reduced vision in the context of a normal ocular health examination, all other pathology must be ruled out before making the diagnosis of functional vision loss. Evaluation must include auxiliary ophthalmologic testing, neuroimaging of the visual pathway, review of the medical history and lifestyle, and psychiatric evaluation. Comanagement with a psychiatrist is essential for patients with functional vision loss.
Aki, Esra; Atasavun, Songül; Kayihan, Holya
2008-06-01
Kinesthetic sense plays an important role in writing. Children with low vision lack sensory input from the environment given their loss of vision. This study assessed the effect of upper extremity kinesthetic sense on writing function in two groups, one of students with low vision (9 girls and 11 boys, 9.4 +/- 1.9 yr. of age) and one of sighted students (10 girls and 10 boys, 10.1 +/- 1.3 yr. of age). All participants were given the Kinesthesia Test and Jebsen Hand Function Test-Writing subtest. Students with low vision scored lower on kinesthetic perception and writing performance than sighted peers. The correlation between scores for writing performance and upper extremity kinesthetic sense in the two groups was significant (r = -.34). The probability of deficiencies in kinesthetic information in students with low vision must be remembered.
NASA Astrophysics Data System (ADS)
Cross, Jack; Schneider, John; Cariani, Pete
2013-05-01
Sierra Nevada Corporation (SNC) has developed rotary and fixed wing millimeter wave radar enhanced vision systems. The Helicopter Autonomous Landing System (HALS) is a rotary-wing enhanced vision system that enables multi-ship landing, takeoff, and enroute flight in Degraded Visual Environments (DVE). HALS has been successfully flight tested in a variety of scenarios, from brown-out DVE landings, to enroute flight over mountainous terrain, to wire/cable detection during low-level flight. The Radar Enhanced Vision Systems (REVS) is a fixed-wing Enhanced Flight Vision System (EFVS) undergoing prototype development testing. Both systems are based on a fast-scanning, threedimensional 94 GHz radar that produces real-time terrain and obstacle imagery. The radar imagery is fused with synthetic imagery of the surrounding terrain to form a long-range, wide field-of-view display. A symbology overlay is added to provide aircraft state information and, for HALS, approach and landing command guidance cuing. The combination of see-through imagery and symbology provides the key information a pilot needs to perform safe flight operations in DVE conditions. This paper discusses the HALS and REVS systems and technology, presents imagery, and summarizes the recent flight test results.
Latency in Visionic Systems: Test Methods and Requirements
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.
2005-01-01
A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.
Project Magnify: Increasing Reading Skills in Students with Low Vision
ERIC Educational Resources Information Center
Farmer, Jeanie; Morse, Stephen E.
2007-01-01
Modeled after Project PAVE (Corn et al., 2003) in Tennessee, Project Magnify is designed to test the idea that students with low vision who use individually prescribed magnification devices for reading will perform as well as or better than students with low vision who use large-print reading materials. Sixteen students with low vision were…
ERIC Educational Resources Information Center
Datta, Poulomee
2014-01-01
There is an absence of research on test anxiety in students with disabilities although such testing is taken for granted among students without disabilities. This study investigated the test anxiety of the students in each of the two disability groups, those with vision impairments and those with intellectual disabilities who are placed in…
Rigaudière, F; Leid, J; Viénot, F; Le Gargasson, J-F
2006-01-01
Vision screening of school children at 5-6 years of age must include color vision screening. X-linked dyschromatopsia is the most frequent disorder affecting 8% of boys and 0.4% of girls. This paper presents the physiology of these deficiencies caused by an alteration of the spectral absorption properties of one of the cone pigments (protanomalous or deuteranomalous trichromats) or the absence of one of the pigments (protanopia or deuteranopia), the most frequent. Absence of two of the pigments (blue cone monochromacy) is very rare and differs from achromatopsia. The physiological basis of the main tests for easy clinical screening are presented. Testing methods designed for children are reviewed. The Ishihara test is the most widely used screening test specific for congenital color defects. If the plates are correctly read, the child has normal color vision. If not, arrangement tests such as Panel D 15 and desaturated Panel D 15 tests can be used to diagnose the type of the defect (protan or deutan) and grade the degree of color deficiency according to a strategy adapted to children. Examples of results are presented for each axis along which caps are confused, providing a quick and easy preliminary diagnosis. Early detection of color vision malfunction in children allows parents and teachers to make necessary adjustments to the teaching methods for appropriate learning.
Giusti, C
2001-01-01
To identify the most appropriate test for screening of early color vision abnormalities in uncomplicated juvenile diabetes. Enrolled in this study were 39 diabetic adolescents, characterized by optimal Early Treatment Diabetic Retinopathy Study criteria for visual acuity, transparent dioptric means and angiographically normal retinas. Color vision was examined with Standard Pseudoisochromatic Plates (Part 2, SPP2), Roth 28-Hue Test (R28), Farnsworth-Munsell 100-Hue Tests (FM100), and Lanthony 15-Hue Desaturated Test (L15). Color confusion score (CCS) and desaturation angle (DSAT) were measured on L15 only. Thirty-nine normal subjects served as a control group. Poor metabolic control was an exclusion criteria. CCS was significantly higher in the patients than in the controls (37.8 +/- 11.1 vs 0 +/- P < .001) and normal scores were found in only 4 diabetic patients. DSAT values were spread, not showing a well-defined axis of the defect. The results of FM100 were clinically reliable but affected by a longer execution time. R28 and SPP2 demonstrated a low sensitivity, as all patients scored normally with both tests. Impaired color vision is a common observation even in patients with uncomplicated juvenile diabetes. Our results indicate that L15 is the most suitable test for screening of early color vision abnormalities in these subjects.
Passing scores for the FAA ATCS Color Vision Test.
DOT National Transportation Integrated Search
1985-08-01
In response to recommendations from the Office of Personnel Management for measures of normal color vision that reflects as closely as possible the functional color vision requirements for an air traffic controller (Christup, 1981), subtests which si...
An ancient eye test--using the stars.
Bohigian, George M
2008-01-01
Vision testing in ancient times was as important as it is today. The predominant vision testing in some cultures was the recognition and identification of constellations and celestial bodies of the night sky. A common ancient naked eye test used the double star of the Big Dipper in the constellation Ursa Major or the Big Bear. The second star from the end of the handle of the Big Dipper is an optical double star. The ability to perceive this separation of these two stars, Mizar and Alcor, was considered a test of good vision and was called the "test" or presently the Arab Eye Test. This article is the first report of the correlation of this ancient eye test to the 20/20 line in the current Snellen visual acuity test. This article describes the astronomy, origin, history, and the practicality of this test and how it correlates with the present day Snellen visual acuity test.
Color vision deficiency in Zahedan, Iran: lower than expected.
Momeni-Moghaddam, Hamed; Ng, Jason S; Robabi, Hassan; Yaghubi, Farshid
2014-11-01
To estimate the prevalence of congenital red-green color vision defects in the elementary school students of Zahedan in 2012. In this cross-sectional study, 1000 students with a mean (±SD) age of 9.0 (±1.4) years were selected randomly from a large primary school population. Color vision was evaluated using the Ishihara pseudoisochromatic color plates (38-plate edition). A daylight fluorescent tube was used as an illuminant C equivalent (i.e., 860 lux, color rendering index greater than 92, and color temperature = 6500 K). Having more than three misreadings on the test was considered a failing criterion. Data were analyzed in SPSS version 17 software using χ2 tests. Nine students (0.9%) made more than three errors on the Ishihara test. Based on this criterion, the prevalence of red-green color vision deficiency in girls and boys was 0.2 and 1.6% (p = 0.02), respectively. The prevalence of red-green color vision deficiency was found to be significantly lower in Zahedan than comparable reports in the literature.
Flight Test Comparison Between Enhanced Vision (FLIR) and Synthetic Vision Systems
NASA Technical Reports Server (NTRS)
Arthur, Jarvis J., III; Kramer, Lynda J.; Bailey, Randall E.
2005-01-01
Limited visibility and reduced situational awareness have been cited as predominant causal factors for both Controlled Flight Into Terrain (CFIT) and runway incursion accidents. NASA s Synthetic Vision Systems (SVS) project is developing practical application technologies with the goal of eliminating low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance. A flight test evaluation was conducted in the summer of 2004 by NASA Langley Research Center under NASA s Aviation Safety and Security, Synthetic Vision System - Commercial and Business program. A Gulfstream G-V aircraft, modified and operated under NASA contract by the Gulfstream Aerospace Corporation, was flown over a 3-week period at the Reno/Tahoe International Airport and an additional 3-week period at the NASA Wallops Flight Facility to evaluate integrated Synthetic Vision System concepts. Flight testing was conducted to evaluate the performance, usability, and acceptance of an integrated synthetic vision concept which included advanced Synthetic Vision display concepts for a transport aircraft flight deck, a Runway Incursion Prevention System, an Enhanced Vision Systems (EVS), and real-time Database Integrity Monitoring Equipment. This paper focuses on comparing qualitative and subjective results between EVS and SVS display concepts.
Color vision deficiency in preschool children: the multi-ethnic pediatric eye disease study.
Xie, John Z; Tarczy-Hornoch, Kristina; Lin, Jesse; Cotter, Susan A; Torres, Mina; Varma, Rohit
2014-07-01
To determine the sex- and ethnicity-specific prevalence of color vision deficiency (CVD) in black, Asian, Hispanic, and non-Hispanic white preschool children. Population-based, cross-sectional study. The Multi-Ethnic Pediatric Eye Disease Study is a population-based evaluation of the prevalence of vision disorders in children in Southern California. A total of 5960 subjects 30 to 72 months of age were recruited for the study, of whom 4177 were able to complete color vision testing (1265 black, 812 Asian, 1280 Hispanic, and 820 non-Hispanic white). Color vision testing was performed using Color Vision Testing Made Easy color plates (Home Vision Care, Gulf Breeze, FL), and diagnostic confirmatory testing was performed using the Waggoner HRR Diagnostic Test color plates (Home Vision Care). Testability of color vision in preschool children between 30 and 72 months of age and prevalence of CVD stratified by age, sex, and ethnicity. Testability was 17% in children younger than 37 months of age, increasing to 57% in children 37 to 48 months of age, 89% in children 49 to 60 months of age, and 98% in children 61 to 72 months of age. The prevalence of CVD among boys was 1.4% for black, 3.1% for Asian, 2.6% for Hispanic, and 5.6% for non-Hispanic white children; the prevalence in girls was 0.0% to 0.5% for all ethnicities. The ethnic difference in CVD was statistically significant between black and non-Hispanic white children (P = 0.0003) and between Hispanic and non-Hispanic white children (P = 0.02). In boys, most CVD cases were either deutan (51%) or protan (34%); 32% were classified as mild, 15% as moderate, and 41% as severe. Testability for CVD in preschool children is high by 4 years of age. The prevalence of CVD in preschool boys varies by ethnicity, with the highest prevalence in non-Hispanic white and lowest in black children. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Comparative effects of pH and Vision herbicide on two life stages of four anuran amphibian species.
Edginton, Andrea N; Sheridan, Patrick M; Stephenson, Gerald R; Thompson, Dean G; Boermans, Herman J
2004-04-01
Vision, a glyphosate-based herbicide containing a 15% (weight:weight) polyethoxylated tallow amine surfactant blend, and the concurrent factor of pH were tested to determine their interactive effects on early life-stage anurans. Ninety-six-hour laboratory static renewal studies, using the embryonic and larval life stages (Gosner 25) of Rana clamitans, R. pipiens, Bufo americanus, and Xenopus laevis, were performed under a central composite rotatable design. Mortality and the prevalence of malformations were modeled using generalized linear models with a profile deviance approach for obtaining confidence intervals. There was a significant (p < 0.05) interaction of pH with Vision concentration in all eight models, such that the toxicity of Vision was amplified by elevated pH. The surfactant is the major toxic component of Vision and is hypothesized, in this study, to be the source of the pH interaction. Larvae of B. americanus and R. clamitans were 1.5 to 3.8 times more sensitive than their corresponding embryos, whereas X. laevis and R. pipiens larvae were 6.8 to 8.9 times more sensitive. At pH values above 7.5, the Vision concentrations expected to kill 50% of the test larvae in 96-h (96-h lethal concentration [LC50]) were predicted to be below the expected environmental concentration (EEC) as calculated by Canadian regulatory authorities. The EEC value represents a worst-case scenario for aerial Vision application and is calculated assuming an application of the maximum label rate (2.1 kg acid equivalents [a.e.]/ha) into a pond 15 cm in depth. The EEC of 1.4 mg a.e./L (4.5 mg/L Vision) was not exceeded by 96-h LC50 values for the embryo test. The larvae of the four species were comparable in sensitivity. Field studies should be completed using the more sensitive larval life stage to test for Vision toxicity at actual environmental concentrations.
Piro, Anna; Tagarelli, Antonio; Nicoletti, Giuseppe; Scannapieco, Sara; Polidoro, Serena; Valentino, Paola; Quattrone, Aldo
2018-02-01
To assess the type and degree of both red-green and blue-yellow color vision deficiencies of Calabrian males affected by multiple sclerosis. Eighty Calabrian male patients were enrolled (age range 18-70 years; mean age 40.6 ± 12.4 years) showing a disease duration mean of 10.6 ± 8.2 years (range = 0.5-46 years) coming from the Institute of Neurology, Magna Graecia University, Catanzaro. Optic neuritis present in the medical histories of the 21 patients does not influence color vision. Excluding seven colorblind subjects and one affected by a bilateral maculopathy, the analyzed sample group was 72. Seventy controls were matched for age and sex. An ophthalmologist examined all patients and controls in order to rule out diabetic retinopathy, cataracts, senile maculopathy, or ocular fundus' anomalies. The Ishihara test identified the colorblind patients. The City University Test screened for people with abnormal color vision by grading the severity of color vision deficiency. The second part of the City University Test as well as the Farnsworth Test confirmed both the color vision deficiency type and degree. Fifty-one percentage (37/72) of the patients showing a color vision deficiency were subdivided into two subgroups: subgroup one showed red-green deficiency (57%, 21/37); subgroup two showed a coupled red-green and blue-yellow deficiency (43%, 16/37). Furthermore, we found two distinct curves showing a groove within the first 10 years of the disease. Both monocular and binocular analyses allowed us to identify the patients showing the monocular color vision deficiency, but they were well compensated by binocular vision. We think that the majority of the patients with the red-green deficiency will develop the coupled red-green and blue-yellow deficiency in the latter years of multiple sclerosis.
Development and evaluation of vision rehabilitation devices.
Luo, Gang; Peli, Eli
2011-01-01
We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.
Function-based design process for an intelligent ground vehicle vision system
NASA Astrophysics Data System (ADS)
Nagel, Robert L.; Perry, Kenneth L.; Stone, Robert B.; McAdams, Daniel A.
2010-10-01
An engineering design framework for an autonomous ground vehicle vision system is discussed. We present both the conceptual and physical design by following the design process, development and testing of an intelligent ground vehicle vision system constructed for the 2008 Intelligent Ground Vehicle Competition. During conceptual design, the requirements for the vision system are explored via functional and process analysis considering the flows into the vehicle and the transformations of those flows. The conceptual design phase concludes with a vision system design that is modular in both hardware and software and is based on a laser range finder and camera for visual perception. During physical design, prototypes are developed and tested independently, following the modular interfaces identified during conceptual design. Prototype models, once functional, are implemented into the final design. The final vision system design uses a ray-casting algorithm to process camera and laser range finder data and identify potential paths. The ray-casting algorithm is a single thread of the robot's multithreaded application. Other threads control motion, provide feedback, and process sensory data. Once integrated, both hardware and software testing are performed on the robot. We discuss the robot's performance and the lessons learned.
Security From Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
Security from Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
Validity of clinical color vision tests for air traffic control specialists.
DOT National Transportation Integrated Search
1992-10-01
An experiment on the relationship between aeromedical color vision screening test performance and performance on color-dependent tasks of Air Traffic Control Specialists was replicated to expand the data base supporting the job-related validity of th...
NASA Astrophysics Data System (ADS)
Näsilä, Antti; Holmlund, Christer; Mannila, Rami; Näkki, Ismo; Ojanen, Harri J.; Akujärvi, Altti; Saari, Heikki; Fussen, Didier; Pieroux, Didier; Demoulin, Philippe
2016-10-01
PICASSO - A PICo-satellite for Atmospheric and Space Science Observations is an ESA project led by the Belgian Institute for Space Aeronomy, in collaboration with VTT Technical Research Centre of Finland Ltd, Clyde Space Ltd. (UK) and Centre Spatial de Liège (BE). The test campaign for the engineering model of the PICASSO VISION instrument, a miniaturized nanosatellite spectral imager, has been successfully completed. The test results look very promising. The proto-flight model of VISION has also been successfully integrated and it is waiting for the final integration to the satellite platform.
Vision preference in dynamic posturography analysed according to vestibular impairment and handicap.
Perez, N I; Rama, J I; Martinez Vila, E
2004-01-01
The objective of this work was to characterise the implications of vision preference derived from the sensory organisation test of computerised dynamic posturography, in terms of impairment, disability and handicap. This was a prospective assessment of 88 patients suffering from dizziness who denied experiencing any visually induced vertiginous symptoms. The level of impairment of each patient was estimated by performing a complete analysis of vestibular function by means of the caloric and rotatory stimulation tests. Disability and handicap were determined with the Dizziness Handicap Inventory questionnaire (DHI). The results of the caloric test in patients were independent of vision preference although canal paresis was more frequently abnormal in patients without visual preference. No differences were found in the results of rotatory stimulation by means of impulse and sinusoidal tests, both at high velocities of stimuli, in between patients with and without vision preference. Similarly, the responses in the DHI, a common questionnaire for vestibular disability and handicap and, specifically to questions addressing the problem of visual and vestibular disability, were not able to differentiate either group of patients. Nevertheless, we have found that patients with vision preference tend to have poorer balance. We consider that in the patients studied here, vision preference must be considered as a normal finding as this represents a normal strategy in a subject that relies more heavily on visual cues for his or her postural control.
Zahiruddin, Kowser; Banu, Shaj; Dharmarajan, Ramya; Kulothungan, Vaitheeswaran; Vijayan, Deepa; Raman, Rajiv; Sharma, Tarun
2010-06-01
To evaluate a customized, portable Farnsworth-Munsell 100 (FM 100) hue viewing booth for compliance with colour vision testing standards and to compare it with room illumination in subjects with normal colour vision (trichromats), subjects with acquired colour vision defects (secondary to diabetes mellitus), and subjects with congenital colour vision defects (dichromats). Discrete wavelengths of the tube in the customized booth were measured using a spectrometer using the normal incident method and were compared with the spectral distribution of sunlight. Forty-eight subjects were recruited for the study and were divided into 3 groups: Group 1, Normal Trichromats (30 eyes); Group 2, Congenital Colour Vision Defects (16 eyes); and Group 3, Diabetes Mellitus (20 eyes). The FM 100 hue test performance was compared using two illumination conditions, booth illumination and room illumination. Total error scores of the classical method in Group 2 as mean+/-SD for room and booth illumination was 243.05+/-85.96 and 149.85+/-54.50 respectively (p=0.0001). Group 2 demonstrated lesser correlation (r=0.50, 0.55), lesser reliability (Cronbach's alpha, 0.625, 0.662) and greater variability (Bland & Altman value, 10.5) in total error scores for the classical method and the moment of inertia method between the two illumination conditions when compared to the other two groups. The customized booth demonstrated illumination meeting CIE standards. The total error scores were overestimated by the classical and moment of inertia methods in all groups for room illumination compared with booth illumination, however overestimation was more significant in the diabetes group.
Acquired color vision deficiency.
Simunovic, Matthew P
2016-01-01
Acquired color vision deficiency occurs as the result of ocular, neurologic, or systemic disease. A wide array of conditions may affect color vision, ranging from diseases of the ocular media through to pathology of the visual cortex. Traditionally, acquired color vision deficiency is considered a separate entity from congenital color vision deficiency, although emerging clinical and molecular genetic data would suggest a degree of overlap. We review the pathophysiology of acquired color vision deficiency, the data on its prevalence, theories for the preponderance of acquired S-mechanism (or tritan) deficiency, and discuss tests of color vision. We also briefly review the types of color vision deficiencies encountered in ocular disease, with an emphasis placed on larger or more detailed clinical investigations. Copyright © 2016 Elsevier Inc. All rights reserved.
Vision Screening for Children 36 to <72 Months: Recommended Practices
Cotter, Susan A.; Cyert, Lynn A.; Miller, Joseph M.; Quinn, Graham E.
2015-01-01
ABSTRACT Purpose This article provides recommendations for screening children aged 36 to younger than 72 months for eye and visual system disorders. The recommendations were developed by the National Expert Panel to the National Center for Children’s Vision and Eye Health, sponsored by Prevent Blindness, and funded by the Maternal and Child Health Bureau of the Health Resources and Services Administration, United States Department of Health and Human Services. The recommendations describe both best and acceptable practice standards. Targeted vision disorders for screening are primarily amblyopia, strabismus, significant refractive error, and associated risk factors. The recommended screening tests are intended for use by lay screeners, nurses, and other personnel who screen children in educational, community, public health, or primary health care settings. Characteristics of children who should be examined by an optometrist or ophthalmologist rather than undergo vision screening are also described. Results There are two current best practice vision screening methods for children aged 36 to younger than 72 months: (1) monocular visual acuity testing using single HOTV letters or LEA Symbols surrounded by crowding bars at a 5-ft (1.5 m) test distance, with the child responding by either matching or naming, or (2) instrument-based testing using the Retinomax autorefractor or the SureSight Vision Screener with the Vision in Preschoolers Study data software installed (version 2.24 or 2.25 set to minus cylinder form). Using the Plusoptix Photoscreener is acceptable practice, as is adding stereoacuity testing using the PASS (Preschool Assessment of Stereopsis with a Smile) stereotest as a supplemental procedure to visual acuity testing or autorefraction. Conclusions The National Expert Panel recommends that children aged 36 to younger than 72 months be screened annually (best practice) or at least once (accepted minimum standard) using one of the best practice approaches. Technological updates will be maintained at http://nationalcenter.preventblindness.org. PMID:25562476
Training improves reading speed in peripheral vision: is it due to attention?
Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J
2010-06-01
Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.
Prevalence of congenital color vision defects in Saudi females of Arab origin.
Alabdelmoneam, Mussaed
2011-09-01
Inherited color vision deficiencies (CVD) vary in prevalence by population and by sex. The most common CVD is X chromosome-linked anomalous trichromacy. Prevalence varies significantly by sex and race. The frequency of color vision defects in Saudi females has not been studied previously. This study surveyed the prevalence of congenital color vision defects in Saudi females of Arab origin. Seven thousand four hundred sixty-seven female subjects (N = 7,467) from the Kingdom of Saudi Arabia were screened using both Ishihara pseudoisochromatic plates and the Farnsworth Dichotomous test (D-15). CVD subjects were tested further with the Farnsworth-Munsell 100 Hue test. Of 7,467 female subjects tested, 26 subjects were found to have defective color vision, for a prevalence of 0.35%. Sixteen subjects had a deutan defect, and 10 had a protan defect. Arab females have significantly lower prevalence of CVD when compared with published data from females of other races. Analysis of the 5 regions of Saudi Arabia showed no significant difference between the regions. Prevalence of CVD among Saudi females of Arab origin is 0.35% and is among the lowest of all published data. Copyright © 2011 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Steinman, Bernard A; Allen, Susan M; Chen, Jie; Pynoos, Jon
2015-02-01
To test whether limitations in mobility and large-muscle functioning mediate self-reported vision status to increase fall risk among respondents age 65 and above. This study used two waves from the Health and Retirement Study. We conducted binary logistic and negative binomial regression analyses to test indirect paths leading from self-reported vision status to falls, via indices of mobility and large-muscle functioning. Limited evidence was found for a mediating effect among women; however, large-muscle groups were implicated as partially mediating risk factors for falls among men with fair self-reported vision status. Implications of these findings are discussed including the need for prioritizing improved muscle strength of older men and women with poor vision as a preventive measure against falls. © The Author(s) 2014.
Color defective vision and the recognition of aviation color signal light flashes.
DOT National Transportation Integrated Search
1971-06-01
A previous study reported on the efficiency with which various tests of color defective vision can predict performance during daylight conditions on a practical test of ability to discriminate aviation signal red, white, and green. In the current stu...
Test of Lander Vision System for Mars 2020
2016-10-04
A prototype of the Lander Vision System for NASA Mars 2020 mission was tested in this Dec. 9, 2014, flight of a Masten Space Systems Xombie vehicle at Mojave Air and Space Port in California. http://photojournal.jpl.nasa.gov/catalog/PIA20848
Vision Screening by Color Photography
NASA Technical Reports Server (NTRS)
Jayroe, R.; Richardson, J. R.; Kerr, J.; Hay, S.; Mcbride, R.
1985-01-01
Screening test developed for detecting a range of vision defects in eye, including common precursors to amblyopia. Test noninvasive, safe, and administered easily in field by operator with no medical training. Only minimal momentary cooperation of subject required: Thus, test shows promise for use with very young children. Test produces color-slide images of retinas of eyes under specially-controlled lighting conditions. Trained observer screens five children per minute.
Impact of Gamification of Vision Tests on the User Experience.
Bodduluri, Lakshmi; Boon, Mei Ying; Ryan, Malcolm; Dain, Stephen J
2017-08-01
Gamification has been incorporated into vision tests and vision therapies in the expectation that it may increase the user experience and engagement with the task. The current study aimed to understand how gamification affects the user experience, specifically during the undertaking of psychophysical tasks designed to estimate vision thresholds (chromatic and achromatic contrast sensitivity). Three tablet computer-based games were developed with three levels of gaming elements. Game 1 was designed to be a simple clinical test (no gaming elements), game 2 was similar to game 1 but with added gaming elements (i.e., feedback, scores, and sounds), and game 3 was a complete game. Participants (N = 144, age: 9.9-42 years) played three games in random order. The user experience for each game was assessed using a Short Feedback Questionnaire. The median (interquartile range) fun level for the three games was 2.5 (1.6), 3.9 (1.7), and 2.5 (2.8), respectively. Overall, participants reported greater fun level and higher preparedness to play the game again for game 2 than games 1 and 3 (P < 0.05). There were significant positive correlations observed between fun level and preparedness to play the game again for all the games (p < 0.05). Engagement (assessed as completion rates) did not differ between the games. Gamified version (game 2) was preferred to the other two versions. Over the short term, the careful application of gaming elements to vision tests was found to increase the fun level of users, without affecting engagement with the vision test.
Effect of microgravity on several visual functions during STS shuttle missions
NASA Technical Reports Server (NTRS)
Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.
1992-01-01
Changes in the acuity of astronaut vision during flight are discussed. Parameters such as critical flicker vision, stereopsis to 10 seconds of arc, visual acuity in small steps to 20/7.7, cyclophoria, lateral and vertical phoria and retinal rivalry were tested using a visual function tester. Twenty-three Space Transportation System (STS) astronauts participated in the experiments. Their vision was assessed twice before launch and after landing, and three to four times while on-orbit and landing. No significant differences during space flight were observed for any of the visual parameters tested. In some cases, slight changes in acuity and stereopsis were observed with a subsequent return to normal vision after flight.
Are middle-age blood pressure levels related to color vision impairment? The Okubo Color Study.
Shoji, Takuhei; Sato, Hiroki; Chihara, Etsuo; Sakurai, Yutaka
2015-01-01
We sought to investigate the association between blood pressure levels and prevalence of acquired color vision impairment in middle-aged Japanese men. Participants underwent color vision testing, ophthalmological examination, standardized interview, physical record examination, and venous blood examination. Cardiovascular disease risk factors were determined based on blood and physical examination results and the interview. Logistic regression analysis was performed after adjusting for body mass index, systemic dyslipidemia, diabetes, cataract, glaucoma, smoking status, and drinking status. Of 1,042 men, 872 were eligible for the study, 130 failed the Lanthony 15-hue desaturated panel (D-15 DS) diagnosed as acquired color vision impairment 15-hue, and 31 failed the Farnsworth-Munsell 100-hue test diagnosed as acquired color vision impairment 100-hue. Diastolic blood pressure was significantly correlated with both acquired color vision impairment in 100-hue patients (adjusted odds ratio (OR) for 10-mm Hg increases = 1.42; 95% confidence interval (CI) = 1.00-2.02) and acquired color vision impairment in 15-hue patients (adjusted OR for 10-mm Hg increases = 1.25; 95% CI = 1.04-1.51). The multiple-adjusted ORs for acquired color vision impairment 100-hue patients and acquired color vision impairment 15-hue patients were 7.13 (95% CI = 1.72-27.88) and 4.37 (95% CI = 1.69-11.03), respectively, for the highest blood pressure category (systolic blood pressure ≥ 160 and diastolic blood pressure ≥ 100 mm Hg) compared with those for the lowest blood pressure category (systolic blood pressure <120 and diastolic blood pressure <80 mm Hg). Tests for trends were significant (P < 0.05) in both analyses. Hypertension in middle-aged men may negatively modify vision-associated neuronal function. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Color defective vision and day and night recognition of aviation color signal light flashes.
DOT National Transportation Integrated Search
1971-07-01
A previous study reported on the efficiency with which various tests of color defective vision can predict performance during daylight conditions on a practical test of ability to discriminate aviation signal red, white, and green. In the current stu...
Dees, Elise W; Baraas, Rigmor C
2014-04-01
Carriers of red-green color-vision deficiencies are generally thought to behave like normal trichromats, although it is known that they may make errors on Ishihara plates. The aim here was to compare the performance of carriers with that of normal females on seven standard color-vision tests, including Ishihara plates. One hundred and twenty-six normal females, 14 protan carriers, and 29 deutan carriers aged 9-66 years were included in the study. Generally, deutan carriers performed worse than protan carriers and normal females on six out of the seven tests. The difference in performance between carriers and normal females was independent of age, but the proportion of carriers that made errors on pseudo-isochromatic tests increased with age. It was the youngest carriers, however, who made the most errors. There was considerable variation in performance among individuals in each group of females. The results are discussed in relation to variability in the number of different L-cone pigments.
Molecular patterns of X chromosome-linked color vision genes among 134 menof European ancestry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drummond-Borg, M.; Deeb, S.S.; Motulsky, A.G.
1989-02-01
The authors used Southern blot hybridization to study X chromosome-linked color vision genes encoding the apoproteins of red and green visual pigments in 134 unselected Caucasian men. One hundred and thirteen individuals (84.3%) had a normal arrangement of their color vision pigment genes. All had one red pigment gene; the number of green pigment genes ranged from one to five with a mode of two. The frequency of molecular genotypes indicative of normal color vision (84.3%) was significantly lower than had been observed in previous studies of color vision phenotypes. Color vision defects can be due to deletions of redmore » or green pigment genes or due to formation of hybrid genes comprising portions of both red and green pigment genes. Characteristic anomalous patterns were seen in 15 (11.2%) individuals: 7 (5.2%) had patterns characteristic of deuteranomaly, 2 (1.5%) had patterns characteristic of deuteranopia, and 6 (4.5%) had protan patterns. Previously undescribed hybrid gene patterns consisting of both green and red pigment gene fragments in addition to normal red and green genes were observed in another 6 individuals (4.5%). Thus, DNA testing detected anomalous color vision pigment genes at a higher frequency than expected from phenotypic color vision tests.« less
Aartolahti, Eeva; Häkkinen, Arja; Lönnroos, Eija; Kautiainen, Hannu; Sulkava, Raimo; Hartikainen, Sirpa
2013-10-01
Vision is an important prerequisite for balance control and mobility. The role of objectively measured visual functions has been previously studied but less is known about associations of functional vision, that refers to self-perceived vision-based ability to perform daily activities. The aim of the study was to investigate the relationship between functional vision and balance and mobility performance in a community-based sample of older adults. This study is part of a Geriatric Multidisciplinary Strategy for the Good Care of the Elderly project (GeMS). Participants (576) aged 76-100 years (mean age 81 years, 70 % women) were interviewed using a seven-item functional vision questionnaire (VF-7). Balance and mobility were measured by the Berg balance scale (BBS), timed up and go (TUG), chair stand test, and maximal walking speed. In addition, self-reported fear of falling, depressive symptoms (15-item Geriatric Depression Scale), cognition (Mini-Mental State Examination) and physical activity (Grimby) were assessed. In the analysis, participants were classified into poor, moderate, or good functional vision groups. The poor functional vision group (n = 95) had more comorbidities, depressed mood, cognition decline, fear of falling, and reduced physical activity compared to participants with moderate (n = 222) or good functional vision (n = 259). Participants with poor functional vision performed worse on all balance and mobility tests. After adjusting for gender, age, chronic conditions, and cognition, the linearity remained statistically significant between functional vision and BBS (p = 0.013), TUG (p = 0.010), and maximal walking speed (p = 0.008), but not between functional vision and chair stand (p = 0.069). Poor functional vision is related to weaker balance and mobility performance in community-dwelling older adults. This highlights the importance of widespread assessment of health, including functional vision, to prevent balance impairment and maintain independent mobility among older population.
Genetic Testing as a New Standard for Clinical Diagnosis of Color Vision Deficiencies.
Davidoff, Candice; Neitz, Maureen; Neitz, Jay
2016-09-01
The genetics underlying inherited color vision deficiencies is well understood: causative mutations change the copy number or sequence of the long (L), middle (M), or short (S) wavelength sensitive cone opsin genes. This study evaluated the potential of opsin gene analyses for use in clinical diagnosis of color vision defects. We tested 1872 human subjects using direct sequencing of opsin genes and a novel genetic assay that characterizes single nucleotide polymorphisms (SNPs) using the MassArray system. Of the subjects, 1074 also were given standard psychophysical color vision tests for a direct comparison with current clinical methods. Protan and deutan deficiencies were classified correctly in all subjects identified by MassArray as having red-green defects. Estimates of defect severity based on SNPs that control photopigment spectral tuning correlated with estimates derived from Nagel anomaloscopy. The MassArray assay provides genetic information that can be useful in the diagnosis of inherited color vision deficiency including presence versus absence, type, and severity, and it provides information to patients about the underlying pathobiology of their disease. The MassArray assay provides a method that directly analyzes the molecular substrates of color vision that could be used in combination with, or as an alternative to current clinical diagnosis of color defects.
Remote-controlled vision-guided mobile robot system
NASA Astrophysics Data System (ADS)
Ande, Raymond; Samu, Tayib; Hall, Ernest L.
1997-09-01
Automated guided vehicles (AGVs) have many potential applications in manufacturing, medicine, space and defense. The purpose of this paper is to describe exploratory research on the design of the remote controlled emergency stop and vision systems for an autonomous mobile robot. The remote control provides human supervision and emergency stop capabilities for the autonomous vehicle. The vision guidance provides automatic operation. A mobile robot test-bed has been constructed using a golf cart base. The mobile robot (Bearcat) was built for the Association for Unmanned Vehicle Systems (AUVS) 1997 competition. The mobile robot has full speed control with guidance provided by a vision system and an obstacle avoidance system using ultrasonic sensors systems. Vision guidance is accomplished using two CCD cameras with zoom lenses. The vision data is processed by a high speed tracking device, communicating with the computer the X, Y coordinates of blobs along the lane markers. The system also has three emergency stop switches and a remote controlled emergency stop switch that can disable the traction motor and set the brake. Testing of these systems has been done in the lab as well as on an outside test track with positive results that show that at five mph the vehicle can follow a line and at the same time avoid obstacles.
Age and visual impairment decrease driving performance as measured on a closed-road circuit.
Wood, Joanne M
2002-01-01
In this study the effects of visual impairment and age on driving were investigated and related to visual function. Participants were 139 licensed drivers (young, middle-aged, and older participants with normal vision, and older participants with ocular disease). Driving performance was assessed during the daytime on a closed-road driving circuit. Visual performance was assessed using a vision testing battery. Age and visual impairment had a significant detrimental effect on recognition tasks (detection and recognition of signs and hazards), time to complete driving tasks (overall course time, reversing, and maneuvering), maneuvering ability, divided attention, and an overall driving performance index. All vision measures were significantly affected by group membership. A combination of motion sensitivity, useful field of view (UFOV), Pelli-Robson letter contrast sensitivity, and dynamic acuity could predict 50% of the variance in overall driving scores. These results indicate that older drivers with either normal vision or visual impairment had poorer driving performance compared with younger or middle-aged drivers with normal vision. The inclusion of tests such as motion sensitivity and the UFOV significantly improve the predictive power of vision tests for driving performance. Although such measures may not be practical for widespread screening, their application in selected cases should be considered.
Genetic Testing as a New Standard for Clinical Diagnosis of Color Vision Deficiencies
Davidoff, Candice; Neitz, Maureen; Neitz, Jay
2016-01-01
Purpose The genetics underlying inherited color vision deficiencies is well understood: causative mutations change the copy number or sequence of the long (L), middle (M), or short (S) wavelength sensitive cone opsin genes. This study evaluated the potential of opsin gene analyses for use in clinical diagnosis of color vision defects. Methods We tested 1872 human subjects using direct sequencing of opsin genes and a novel genetic assay that characterizes single nucleotide polymorphisms (SNPs) using the MassArray system. Of the subjects, 1074 also were given standard psychophysical color vision tests for a direct comparison with current clinical methods. Results Protan and deutan deficiencies were classified correctly in all subjects identified by MassArray as having red–green defects. Estimates of defect severity based on SNPs that control photopigment spectral tuning correlated with estimates derived from Nagel anomaloscopy. Conclusions The MassArray assay provides genetic information that can be useful in the diagnosis of inherited color vision deficiency including presence versus absence, type, and severity, and it provides information to patients about the underlying pathobiology of their disease. Translational Relevance The MassArray assay provides a method that directly analyzes the molecular substrates of color vision that could be used in combination with, or as an alternative to current clinical diagnosis of color defects. PMID:27622081
Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan
2017-06-06
Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable.
Hu, Qijun; He, Songsheng; Wang, Shilong; Liu, Yugang; Zhang, Zutao; He, Leping; Wang, Fubin; Cai, Qijie; Shi, Rendan; Yang, Yuan
2017-01-01
Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable. PMID:28587275
Colorimetric evaluation of iPhone apps for colour vision tests based on the Ishihara test.
Dain, Stephen J; AlMerdef, Ali
2016-05-01
Given the versatility of smart phone displays, it was inevitable that applications (apps) providing colour vision testing would appear as an option. In this study, the colorimetric characteristics of five available iPhone apps for colour vision testing are assessed as a prequel to possible clinical evaluation. The colours of the displays produced by the apps are assessed with reference to the colours of a printed Ishihara test. The visual task is assessed on the basis of the colour differences and the alignment to the dichromatic confusion lines. The apps vary in quality and while some are colorimetrically acceptable, there are also some problems with their construction in making them a clinically useful app rather than curiosity driven self-testing. There is no reason why, in principle, a suitable test cannot be designed for smart phones. © 2016 Optometry Australia.
Influence of retinopathy on the achromatic and chromatic vision of patients with type 2 diabetes
2014-01-01
Background Luminance contrast sensitivity and colour vision are considered to have great predictive value in the evaluation of type 2 diabetic retinopathy. However, these two visual characteristics have seldom been investigated in the same group of patients. In the present study we measured contrast sensitivity and colour vision in a group of patients with type 2 diabetes and correlated the results with estimates of common metabolic markers for the disease. A subgroup of the patients had no clinical signs of retinopathy. Methods The vision of 27 patients (n = 50 eyes) with type 2 diabetes, with retinopathy (n = 20 eyes), or without retinopathy (n = 30 eyes) were evaluated using two psychophysical tests, the Farnsworth–Munsell 100 hue test (FM 100), and measurements of the luminance contrast sensitivity at 11 spatial frequencies. The results were compared with measurements obtained from an age-matched control group (n = 32), and were correlated with the level of glycated haemoglobin, glycaemic level, and time of disease onset. Signs of retinopathy were identified during the ophthalmological examinations. Results Contrast sensitivity and colour vision impairments were present at different levels in diabetes patients. Eyes with retinopathy showed more severe vision loss than eyes without retinopathy. The FM 100 test was more sensitive for separation of patients from controls. Colour vision loss had no colour axes preference. The contrast sensitivity test appeared to have some advantage in differentiating patients with retinopathy from patients without retinopathy. Conclusions Both methods can be useful to follow the visual function of diabetic patients and should be used together to discriminate patients from controls, as well as to identify early signs of retinal damage. PMID:25174264
A Unified Taxonomic Approach to the Laboratory Assessment of Visionic Devices
2006-09-01
the ratification stage with member nations. Marasco and Task 4 presented a large array of tests applicable to image intensification-based visionic...aircraft.” In print. 4. Marasco , P. L., and Task, H. L. 1999. “Optical characterization of wide field-of-view night vision devices,” in
Code of Federal Regulations, 2010 CFR
2010-07-01
... distance and near vision using Snellen's test type or its equivalent. (b) Evaluation of visual acuity. (1) Evaluate central visual acuity on the basis of corrected distance vision with central fixation, even if a central scotoma is present. However, when the lens required to correct distance vision in the poorer eye...
Code of Federal Regulations, 2011 CFR
2011-07-01
... distance and near vision using Snellen's test type or its equivalent. (b) Evaluation of visual acuity. (1) Evaluate central visual acuity on the basis of corrected distance vision with central fixation, even if a central scotoma is present. However, when the lens required to correct distance vision in the poorer eye...
Aeromedical implications of the X-Chrom lens for improving color vision deficiencies.
DOT National Transportation Integrated Search
1978-04-01
The X-Chrom contact lens is a recent device recommended to improve defective color vision. The red lens is usually worn on the nondominant eye and may require extended wearing for optimum color vision enhancement. A battery of tests was given to 24 i...
Learning from vision-to-touch is different than learning from touch-to-vision.
Wismeijer, Dagmar A; Gegenfurtner, Karl R; Drewing, Knut
2012-01-01
We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "novel" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.
The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site
Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.
2017-01-01
SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They show promise for the clinical objective of advising the patient and his/her caregivers about the success the patient is likely to enjoy in tasks of everyday life. PMID:28972542
Vision Test Validation Study for the Health Examination Survey Among Youths 12-17 years.
ERIC Educational Resources Information Center
Roberts, Jean
A validation study of the vision test battery used in the Health Examination Survey of 1966-1970 was conducted among 210 youths 12-17 years-old who had been part of the larger survey. The study was designed to discover the degree of correspondence between survey test results and clinical examination by an opthalmologist in determining the…
Prevalence of color vision deficiency among arc welders.
Heydarian, Samira; Mahjoob, Monireh; Gholami, Ahmad; Veysi, Sajjad; Mohammadi, Morteza
This study was performed to investigate whether occupationally related color vision deficiency can occur from welding. A total of 50 male welders, who had been working as welders for at least 4 years, were randomly selected as case group, and 50 age matched non-welder men, who lived in the same area, were regarded as control group. Color vision was assessed using the Lanthony desatured panel D-15 test. The test was performed under the daylight fluorescent lamp with a spectral distribution of energy with a color temperature of 6500K and a color rendering index of 94 that provided 1000lx on the work plane. The test was carried out monocularly and no time limit was imposed. All data analysis were performed using SPSS, version 22. The prevalence of dyschromatopsia among welders was 15% which was statistically higher than that of nonwelder group (2%) (p=0.001). Among welders with dyschromatopsia, color vision deficiency in 72.7% of cases was monocular. There was positive relationship between the employment length and color vision loss (p=0.04). Similarly, a significant correlation was found between the prevalence of color vision deficiency and average working hours of welding a day (p=0.025). Chronic exposure to welding light may cause color vision deficiency. The damage depends on the exposure duration and the length of their employment as welders. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Postuma, Ronald B; Gagnon, Jean-François; Vendette, Mélanie; Desjardins, Catherine; Montplaisir, Jacques Y
2011-05-01
For development of neuroprotective therapy, neurodegenerative disease must be identified as early as possible. However, current means of identifying "preclinical" neurodegeneration are limited. Patients with idiopathic rapid eye movement (REM) sleep behavior disorder (RBD) are at >50% risk of synuclein-mediated neurodegenerative disease--this provides a unique opportunity to directly observe preclinical synucleinopathy and to test potential markers of preclinical disease. Patients with RBD without neurodegenerative disease were enrolled in a prospective cohort starting in 2004. Olfaction and color vision were tested at baseline, then annually for 5 years. Test results were compared between patients who developed neurodegenerative disease and those who remained disease-free. Out of 64 patients, 62 (97%) participated in annual follow-up. During follow-up, 21 developed disease, and 41 remained disease-free. Out of 21, 16 developed a combination of parkinsonism and dementia, 4 developed isolated parkinsonism (all with tremor), and 1 developed isolated dementia. Compared to those remaining disease-free, patients destined to develop disease had worse baseline olfaction (University of Pennsylvania Smell Identification Test [UPSIT] = 58.3 ± 27.0% age/sex-adjusted normal vs 80.2 ± 26.3%; p = 0.003) and color vision (Farnsworth-Munsell 100-Hue color test [FM-100] errors 153.0 ± 82.2% normal vs 120.2 ± 26.5%; p = 0.022). Kaplan-Meier 5-year-disease-free survival in those with normal olfaction was 86.0%, vs 35.4% with impaired olfaction (p = 0.029). Disease-free survival with normal color vision was 70.3%, vs 26.0% with impaired vision (p = 0.009). Both olfaction and color vision were reduced as much as 5 years before disease diagnosis, with only slight decline in preclinical stages. Olfaction and color vision identify early-stage synuclein-mediated neurodegenerative diseases. In most cases, abnormalities are measurable at least 5 years before disease onset, and progress slowly in the preclinical stages. Copyright © 2011 American Neurological Association.
Audible vision for the blind and visually impaired in indoor open spaces.
Yu, Xunyi; Ganz, Aura
2012-01-01
In this paper we introduce Audible Vision, a system that can help blind and visually impaired users navigate in large indoor open spaces. The system uses computer vision to estimate the location and orientation of the user, and enables the user to perceive his/her relative position to a landmark through 3D audio. Testing shows that Audible Vision can work reliably in real-life ever-changing environment crowded with people.
Clinical color vision testing and correlation with visual function.
Zhao, Jiawei; Davé, Sarita B; Wang, Jiangxia; Subramanian, Prem S
2015-09-01
To determine if Hardy-Rand-Rittler (H-R-R) and Ishihara testing are accurate estimates of color vision in subjects with acquired visual dysfunction. Assessment of diagnostic tools. Twenty-two subjects with optic neuropathy (aged 18-65) and 18 control subjects were recruited prospectively from an outpatient clinic. Individuals with visual acuity (VA) <20/200 or with congenital color blindness were excluded. All subjects underwent a comprehensive eye examination including VA, color vision, and contrast sensitivity testing. Color vision was assessed using H-R-R and Ishihara plates and Farnsworth D-15 (D-15) discs. D-15 is the accepted standard for detecting and classifying color vision deficits. Contrast sensitivity was measured using Pelli-Robson contrast sensitivity charts. No relationship was found between H-R-R and D-15 scores (P = .477). H-R-R score and contrast sensitivity were positively correlated (P = .003). On multivariate analysis, contrast sensitivity (β = 8.61, P < .001) and VA (β = 2.01, P = .022) both showed association with H-R-R scores. Similar to H-R-R, Ishihara score did not correlate with D-15 score (P = .973), but on multivariate analysis was related to contrast sensitivity (β = 8.69, P < .001). H-R-R and Ishihara scores had an equivalent relationship with contrast sensitivity (P = .069). Neither H-R-R nor Ishihara testing appears to assess color identification in patients with optic neuropathy. Both H-R-R and Ishihara testing are correlated with contrast sensitivity, and these tests may be useful clinical surrogates for contrast sensitivity testing. Copyright © 2015 Elsevier Inc. All rights reserved.
Visual Advantage of Enhanced Flight Vision System During NextGen Flight Test Evaluation
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Harrison, Stephanie J.; Bailey, Randall E.; Shelton, Kevin J.; Ellis, Kyle K.
2014-01-01
Synthetic Vision Systems and Enhanced Flight Vision System (SVS/EFVS) technologies have the potential to provide additional margins of safety for aircrew performance and enable operational improvements for low visibility operations in the terminal area environment. Simulation and flight tests were jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA) to evaluate potential safety and operational benefits of SVS/EFVS technologies in low visibility Next Generation Air Transportation System (NextGen) operations. The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SVS/EFVS operational and system-level performance capabilities. Nine test flights were flown in Gulfstream's G450 flight test aircraft outfitted with the SVS/EFVS technologies under low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 feet to 3600 feet reported visibility) under different obscurants (mist, fog, drizzle fog, frozen fog) and sky cover (broken, overcast). Flight test videos were evaluated at three different altitudes (decision altitude, 100 feet radar altitude, and touchdown) to determine the visual advantage afforded to the pilot using the EFVS/Forward-Looking InfraRed (FLIR) imagery compared to natural vision. Results indicate the EFVS provided a visual advantage of two to three times over that of the out-the-window (OTW) view. The EFVS allowed pilots to view the runway environment, specifically runway lights, before they would be able to OTW with natural vision.
The Future of Toxicity Testing - the NRC Vision and EPA’s ToxCast Program
The EPA requested the National Research Council (NRC) to develop a vision and strategic plan for toxicity testing in the 21st century. The 2007 report called for transforming toxicology to provide a robust scientific basis for assessing adverse health effects of environmental age...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-30
... Automation, Inc. (``Amistar'') of San Marcos, California; Techno Soft Systemnics, Inc. (``Techno Soft'') of... the claim terms ``test,'' ``match score surface,'' and ``gradient direction,'' all of his infringement... complainants' proposed construction for the claim terms ``test,'' ``match score surface,'' and ``gradient...
Predicting the clinical performance of dental students with a manual dexterity test
Lugassy, Diva; Levanon, Yafi; Pilo, Raphael; Shelly, Asaf; Rosen, Gal; Meirowitz, Avi
2018-01-01
Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O’Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students’ improvement after phantom training. The dentists’ performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O’Connor test). A regression analysis showed that students’ manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O’Connor test under indirect vision predicted phantom course success in 80% of cases. The O’Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies. PMID:29518127
A Performance Comparison of Color Vision Tests for Military Screening.
Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A
2016-04-01
Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.
Hulka, Lea M; Wagner, Michael; Preller, Katrin H; Jenni, Daniela; Quednow, Boris B
2013-04-01
Specific blue-yellow colour vision impairment has been reported in dependent cocaine users and it was postulated that drug-induced changes in retinal dopamine neurotransmission are responsible. However, it is unclear whether these changes are confined to chronic cocaine users, whether they are specific for dopaminergic stimulants such as cocaine and amphetamine and whether they are related to cognitive functions such as working memory, encoding and consolidation. In 47 occasional and 29 dependent cocaine users, 23 MDMA (commonly known as 'ecstasy') users and 47 stimulant-naive controls, colour vision discrimination was measured with the Lanthony Desaturated Panel D-15 Test and memory performance with the Auditory Verbal Learning Test. Both occasional and dependent cocaine users showed higher colour confusion indices than controls. Users of the serotonergic stimulant MDMA (26%), occasional (30%) and dependent cocaine users (34%) exhibited more frequent blue-yellow colour vision disorders compared to controls (9%). Inferior performance of MDMA users was caused by a subgroup with high amphetamine co-use (55%), while MDMA use alone was not associated with decreased blue-yellow discrimination (0%). Cognitive performance was worse in cocaine users with colour vision disorder compared to users and controls with intact colour vision and both colour vision impairment and cognitive deficits were related to cocaine use. Occasional cocaine and amphetamine use might induce blue-yellow colour vision impairment, whereas the serotonergic stimulant MDMA does not impair colour vision. The association between colour vision impairment and cognitive deficits in cocaine users may reflect that retinal and cerebral dopamine alterations are linked to a certain degree.
A novel color vision test for detection of diabetic macular edema.
Shin, Young Joo; Park, Kyu Hyung; Hwang, Jeong-Min; Wee, Won Ryang; Lee, Jin Hak; Lee, In Bum; Hyon, Joon Young
2014-01-02
To determine the sensitivity of the Seoul National University (SNU) computerized color vision test for detecting diabetic macular edema. From May to September 2003, a total of 73 eyes of 73 patients with diabetes mellitus were examined using the SNU computerized color vision test and optical coherence tomography (OCT). Color deficiency was quantified as the total error score on the SNU test and as error scores for each of four color quadrants corresponding to yellows (Q1), greens (Q2), blues (Q3), and reds (Q4). SNU error scores were assessed as a function of OCT foveal thickness and total macular volume (TMV). The error scores in Q1, Q2, Q3, and Q4 measured by the SNU color vision test increased with foveal thickness (P < 0.05), whereas they were not correlated with TMV. Total error scores, the summation of Q1 and Q3, the summation of Q2 and Q4, and blue-yellow (B-Y) error scores were significantly correlated with foveal thickness (P < 0.05), but not with TMV. The observed correlation between SNU color test error scores and foveal thickness indicates that the SNU test may be useful for detection and monitoring of diabetic macular edema.
The Ability of Children with Low Vision to Recall Pictures.
ERIC Educational Resources Information Center
Corley, G.; Pring, L.
1996-01-01
Three experiments tested the ability of 11 children (ages 6-10) with low vision to recall black-and-white line drawings. Unlike fully sighted age-matched controls, children with low vision recalled best when left to study pictures without verbal intervention. They also named significantly fewer of the remembered pictures correctly. (Author/PB)
The Development of Peripheral Vision in Infants.
ERIC Educational Resources Information Center
Guez, Jean R.
This study investigated the extent of infant peripheral vision, specifically the extent of infants' constricted field, or tunnel vision. Thirteen infants, 2 to 5 months old, were tested using a psychophysical procedure to obtain contrast sensitivity thresholds at four retinal loci (-40, -15, +15, +40 deg.). Infants were placed in an infant bed in…
ERIC Educational Resources Information Center
Marks, Ron
The study evaluated the validity, reliability, and effectiveness in providing needed information of the Montana Functional Vision Assessment (MFVA) Instrument by comparing it with the Texas Education Agency Functional Vision Assessment and field testing the instrument in evaluations of nine multihandicapped students (ages 3-11). Evaluation led to…
46 CFR 10.215 - Medical and physical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... Table 10.215(a)—Medical and Physical Requirements for Mariner Endorsements Credential Vision test... on vessels to which STCW applies, other than those listed above § 10.215(e)(2) (b) Vision Test—(1) Deck Standard. An applicant must have correctable vision to at least 20/40 in one eye and uncorrected...
DOT National Transportation Integrated Search
2006-02-01
This report describes the status of color use in current air traffic control (ATC) displays. It represents the first step in our effort to reexamine the color vision standards for air traffic controllers. The current job-related color vision tests us...
Driving and Low Vision: Validity of Assessments for Predicting Performance of Drivers
ERIC Educational Resources Information Center
Strong, J. Graham; Jutai, Jeffrey W.; Russell-Minda, Elizabeth; Evans, Mal
2008-01-01
The authors conducted a systematic review to examine whether vision-related assessments can predict the driving performance of individuals who have low vision. The results indicate that measures of visual field, contrast sensitivity, cognitive and attention-based tests, and driver screening tools have variable utility for predicting real-world…
Performing pediatric eye exams in primary care.
Martin, Elaine F
2017-08-17
Early vision care is critical for all children. If undetected, eye disorders such as amblyopia and strabismus may result in permanent vision loss. Vision exams should include a careful history and physical including fix and follow, red reflex, and cover/uncover testing. Photo screening and visual acuity exams should be administered whenever possible.
Computerized Color Vision Test Based Upon Postreceptoral Channel Sensitivities
E, Miyahara; J, Pokorny; VC, Smith; E, Szewczyk; J, McCartin; K, Caldwell; A, Klerer
2006-01-01
An automated, computerized color vision test was designed to diagnose congenital red-green color vision defects. The observer viewed a yellow appearing CRT screen. The principle was to measure increment thresholds for three different chromaticities, the background yellow, a red, and a green chromaticity. Spatial and temporal parameters were chosen to favor parvocellular pathway mediation of thresholds. Thresholds for the three test stimuli were estimated by 4AFC, randomly interleaved staircases. Four 1.5°, 4.2 cd/m2 square pedestals were arranged as a 2 x 2 matrix around the center of the display with 15’ separations. A trial incremented all four squares by 1.0 cd/m2 for 133 msec. One randomly chosen square included an extra increment of a test chromaticity. The observer identified the different appearing square using the cursor. Administration time was ~5 minutes. Normal trichromats showed clear Sloan notch as defined by log (ΔY/ΔR), whereas red-green color defectives generally showed little or no Sloan notch, indicating that their thresholds were mediated by their luminance system, not by the chromatic system. Data from 107 normal trichromats showed a mean Sloan notch of 0.654 (SD = 0.123). Among 16 color vision defectives tested (2 protanopes, 1 protanomal, 6 deuteranopes, 7 deuteranomals), the Sloan notch was between −0.062 and 0.353 for deutans and was < −0.10 for protans. A sufficient number of color defective observers have not yet been tested to determine whether the test can reliably discriminate between protans and deutans. Nevertheless, the current data show that the test can work as a quick diagnostic procedure (functional trichromatism or dichromatism) of red-green color vision defect. PMID:15518231
The main goal of Toxicity Testing in the 21st Century: A Vision and A Strategy(1) is to provide a practical means of evaluating the heath risks of chemicals. The vision is in stark contrast to the current situation, where the focus on apical testing in vivo is too expensive and t...
Learning from vision-to-touch is different than learning from touch-to-vision
Wismeijer, Dagmar A.; Gegenfurtner, Karl R.; Drewing, Knut
2012-01-01
We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two “natural” tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two “novel” tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision. PMID:23181012
Developing a Very Low Vision Orientation and Mobility Test Battery (O&M-VLV).
Finger, Robert P; Ayton, Lauren N; Deverell, Lil; O'Hare, Fleur; McSweeney, Shane C; Luu, Chi D; Fenwick, Eva K; Keeffe, Jill E; Guymer, Robyn H; Bentley, Sharon A
2016-09-01
This study aimed to determine the feasibility of an assessment of vision-related orientation and mobility (O&M) tasks in persons with severe vision loss. These tasks may be used for future low vision rehabilitation clinical assessments or as outcome measures in vision restoration trials. Forty legally blind persons (mean visual acuity logMAR 2.3, or hand movements) with advanced retinitis pigmentosa participated in the Orientation & Mobility-Very Low Vision (O&M-VLV) subtests from the Low Vision Assessment of Daily Activities (LoVADA) protocol. Four categories of tasks were evaluated: route travel in three indoor hospital environments, a room orientation task (the "cafe"), a visual exploration task (the "gallery"), and a modified version of the Timed Up and Go (TUG) test, which assesses re-orientation and route travel. Spatial cognition was assessed using the Stuart Tactile Maps test. Visual acuity and visual fields were measured. A generalized linear regression model showed that a number of measures in the O&M-VLV tasks were related to residual visual function. The percentage of preferred walking speed without an aid on three travel routes was associated with visual field (p < 0.01 for all routes) whereas the number of contacts with obstacles during route travel was associated with acuity (p = 0.001). TUG-LV task time was associated with acuity (p = 0.003), as was the cafe time and distance traveled (p = 0.006 and p < 0.001, respectively). The gallery score was the only measure that was significantly associated with both residual acuity and fields (p < 0.001 and p = 0.001, respectively). The O&M-VLV was designed to capture key elements of O&M performance in persons with severe vision loss, which is a population not often studied previously. Performance on these tasks was associated with both binocular visual acuity and visual field. This new protocol includes assessments of orientation, which may be of benefit in vision restoration clinical trials.
Bair, Woei-Nan; Barela, José A.; Whitall, Jill; Jeka, John J.; Clark, Jane E.
2011-01-01
In two experiments, the ability to use multisensory information (haptic information, provided by lightly touching a stationary surface, and vision) for quiet standing was examined in typically developing (TD) children, adults, and in 7-year-old children with Developmental Coordination Disorder (DCD). Four sensory conditions (no touch/no vision, with touch/no vision, no touch/with vision, and with touch/with vision) were employed. In experiment 1, we tested 4-, 6- and 8-year-old TD children and adults to provide a developmental landscape for performance on this task. In experiment 2, we tested a group of 7-year-old children with DCD and their age-matched TD peers. For all groups, touch robustly attenuated standing sway suggesting that children as young as 4 years old use touch information similarly to adults. Touch was less effective in children with DCD compared to their TD peers, especially in attenuating their sway velocity. Children with DCD, unlike their TD peers, also benefited from using vision to reduce sway. The present results suggest that children with DCD benefit from using vision in combination with touch information for standing control possibly due to their less well developed internal models of body orientation and self-motion. Internal model deficits, combined with other known deficits such as postural muscles activation timing deficits, may exacerbate the balance impairment in children with DCD. PMID:21571533
West, Kristine L.; Lee, Jongwook
2018-01-01
More than 20 percent of all school-aged children in the United States have vision problems, and low-income and minority children are disproportionately likely to have unmet vision care needs. Vision screening is common in U.S. schools, but it remains an open question whether screening alone is sufficient to improve student outcomes. We implemented a multi-armed randomized controlled trial to evaluate the impact of vision screening, and of vision screening accompanied by eye exams and eyeglasses, provided by a non-profit organization to Title I elementary schools in three large central Florida school districts. We find that providing additional/enhanced screening alone is generally insufficient to improve student achievement in math and reading. In contrast, providing screening along with free eye exams and free eyeglasses to students with vision problems improved student achievement as measured by standardized test scores. We find, averaging over all students (including those without vision problems), that this more comprehensive intervention increased the probability of passing the Florida Comprehensive Achievement Tests (FCAT) in reading and math by approximately 2.0 percentage points. We also present evidence that indicates that this impact fades out over time, indicating that follow-up actions after the intervention may be necessary to sustain these estimated achievement gains. PMID:29693366
SMALL COLOUR VISION VARIATIONS AND THEIR EFFECT IN VISUAL COLORIMETRY,
COLOR VISION, PERFORMANCE(HUMAN), TEST EQUIPMENT, PERFORMANCE(HUMAN), CORRELATION TECHNIQUES, STATISTICAL PROCESSES, COLORS, ANALYSIS OF VARIANCE, AGING(MATERIALS), COLORIMETRY , BRIGHTNESS, ANOMALIES, PLASTICS, UNITED KINGDOM.
Flight Testing an Integrated Synthetic Vision System
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Arthur, Jarvis J., III; Bailey, Randall E.; Prinzel, Lawrence J., III
2005-01-01
NASA's Synthetic Vision Systems (SVS) project is developing technologies with practical applications to eliminate low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance for transport aircraft. The SVS concept being developed at NASA encompasses the integration of tactical and strategic Synthetic Vision Display Concepts (SVDC) with Runway Incursion Prevention System (RIPS) alerting and display concepts, real-time terrain database integrity monitoring equipment (DIME), and Enhanced Vision Systems (EVS) and/or improved Weather Radar for real-time object detection and database integrity monitoring. A flight test evaluation was jointly conducted (in July and August 2004) by NASA Langley Research Center and an industry partner team under NASA's Aviation Safety and Security, Synthetic Vision System project. A Gulfstream GV aircraft was flown over a 3-week period in the Reno/Tahoe International Airport (NV) local area and an additional 3-week period in the Wallops Flight Facility (VA) local area to evaluate integrated Synthetic Vision System concepts. The enabling technologies (RIPS, EVS and DIME) were integrated into the larger SVS concept design. This paper presents experimental methods and the high level results of this flight test.
Ability Structure and Loss of Vision. Research Series, Number 18.
ERIC Educational Resources Information Center
Juurmaa, Jyrki
In the analysis of ability structure and loss of vision, 228 blind persons (153 male, 75 female) heterogenous in respect to chronological age, sex, degree of blindness, age at onset, and duration, were compared to sighted controls. A test battery was administered which included tests for verbal comprehension, mental arithmetic, spatial ability,…
Tox21: Putting a Lens on the Vision of Toxicity Testing in the 21st Century
In response to the release of the NRC report on "Toxicity Testing in the 21st Century, a Vision and Strategy" (NRC, 2007), two NIH institutes and EPA formed a collaboration (Tox21) to 1) identify mechanisms of chemically induced biological activity, 2) prioritize chemicals for mo...
A physiologically-based model for simulation of color vision deficiency.
Machado, Gustavo M; Oliveira, Manuel M; Fernandes, Leandro A F
2009-01-01
Color vision deficiency (CVD) affects approximately 200 million people worldwide, compromising the ability of these individuals to effectively perform color and visualization-related tasks. This has a significant impact on their private and professional lives. We present a physiologically-based model for simulating color vision. Our model is based on the stage theory of human color vision and is derived from data reported in electrophysiological studies. It is the first model to consistently handle normal color vision, anomalous trichromacy, and dichromacy in a unified way. We have validated the proposed model through an experimental evaluation involving groups of color vision deficient individuals and normal color vision ones. Our model can provide insights and feedback on how to improve visualization experiences for individuals with CVD. It also provides a framework for testing hypotheses about some aspects of the retinal photoreceptors in color vision deficient individuals.
Photoreceptor Cells With Profound Structural Deficits Can Support Useful Vision in Mice
Thompson, Stewart; Blodi, Frederick R.; Lee, Swan; Welder, Chris R.; Mullins, Robert F.; Tucker, Budd A.; Stasheff, Steven F.; Stone, Edwin M.
2014-01-01
Purpose. In animal models of degenerative photoreceptor disease, there has been some success in restoring photoreception by transplanting stem cell–derived photoreceptor cells into the subretinal space. However, only a small proportion of transplanted cells develop extended outer segments, considered critical for photoreceptor cell function. The purpose of this study was to determine whether photoreceptor cells that lack a fully formed outer segment could usefully contribute to vision. Methods. Retinal and visual function was tested in wild-type and Rds mice at 90 days of age (RdsP90). Photoreceptor cells of mice homozygous for the Rds mutation in peripherin 2 never develop a fully formed outer segment. The electroretinogram and multielectrode recording of retinal ganglion cells were used to test retinal responses to light. Three distinct visual behaviors were used to assess visual capabilities: the optokinetic tracking response, the discrimination-based visual water task, and a measure of the effect of vision on wheel running. Results. RdsP90 mice had reduced but measurable electroretinogram responses to light, and exhibited light-evoked responses in multiple types of retinal ganglion cells, the output neurons of the retina. In optokinetic and discrimination-based tests, acuity was measurable but reduced, most notably when contrast was decreased. The wheel running test showed that RdsP90 mice needed 3 log units brighter luminance than wild type to support useful vision (10 cd/m2). Conclusions. Photoreceptors that lack fully formed outer segments can support useful vision. This challenges the idea that normal cellular structure needs to be completely reproduced for transplanted cells to contribute to useful vision. PMID:24569582
Relating binocular and monocular vision in strabismic and anisometropic amblyopia.
Agrawal, Ritwick; Conner, Ian P; Odom, J V; Schwartz, Terry L; Mendola, Janine D
2006-06-01
To examine deficits in monocular and binocular vision in adults with amblyopia and to test the following 2 hypotheses: (1) Regardless of clinical subtype, the degree of impairment in binocular integration predicts the pattern of monocular acuity deficits. (2) Subjects who lack binocular integration exhibit the most severe interocular suppression. Seven subjects with anisometropia, 6 subjects with strabismus, and 7 control subjects were tested. Monocular tests included Snellen acuity, grating acuity, Vernier acuity, and contrast sensitivity. Binocular tests included Titmus stereo test, binocular motion integration, and dichoptic contrast masking. As expected, both groups showed deficits in monocular acuity, with subjects with strabismus showing greater deficits in Vernier acuity. Both amblyopic groups were then characterized according to the degree of residual stereoacuity and binocular motion integration ability, and 67% of subjects with strabismus compared with 29% of subjects with anisometropia were classified as having "nonbinocular" vision according to our criterion. For this nonbinocular group, Vernier acuity is most impaired. In addition, the nonbinocular group showed the most dichoptic contrast masking of the amblyopic eye and the least dichoptic contrast masking of the fellow eye. The degree of residual binocularity and interocular suppression predicts monocular acuity and may be a significant etiological mechanism of vision loss.
Stürmer, Kathleen; Könings, Karen D; Seidel, Tina
2013-09-01
Teachers' professional vision includes the ability to apply general pedagogical knowledge about components of effective teaching and learning to reason about significant features of classroom practice. It requires teachers to (a) describe, (b) explain, and (c) predict classroom situations. Although the acquisition of underling knowledge can be considered as a key element of university-based teacher education programmes, to date, there has been little empirical research on teacher candidates' development of professional vision. This study aims to improve understanding of how different university-based courses in teaching and learning impact the development of professional vision. Participants were teacher candidates (N= 53) attending the same teacher education programme at a German university. They were enrolled in one of three different compulsory courses in teaching and learning, lasting one semester. In a pre-test-post-test design, participants' declarative knowledge about teaching and learning was measured with a test, professional vision with the online tool Observer. Analysis of covariance and multivariate analysis of variance were conducted. Teacher candidates in all three courses showed significant gains both in declarative knowledge and professional vision. Patterns of results differed depending on the course attended. A video-based course with a focus on effective teaching resulted in highest gains in prediction of the consequences of observed events for student learning processes, which is the highest level of knowledge transfer. The development of professional vision is a strongly knowledge-guided process. In line with their content and aims, university-based courses can enhance teaching-relevant knowledge for teacher candidates. © 2012 The British Psychological Society.
Mazella, Anaïs; Albaret, Jean-Michel; Picard, Delphine
2016-01-01
To fill an important gap in the psychometric assessment of children and adolescents with impaired vision, we designed a new battery of haptic tests, called Haptic-2D, for visually impaired and sighted individuals aged five to 18 years. Unlike existing batteries, ours uses only two-dimensional raised materials that participants explore using active touch. It is composed of 11 haptic tests, measuring scanning skills, tactile discrimination skills, spatial comprehension skills, short-term tactile memory, and comprehension of tactile pictures. We administered this battery to 138 participants, half of whom were sighted (n=69), and half visually impaired (blind, n=16; low vision, n=53). Results indicated a significant main effect of age on haptic scores, but no main effect of vision or Age × Vision interaction effect. Reliability of test items was satisfactory (Cronbach's alpha, α=0.51-0.84). Convergent validity was good, as shown by a significant correlation (age partialled out) between total haptic scores and scores on the B101 test (rp=0.51, n=47). Discriminant validity was also satisfactory, as attested by a lower but still significant partial correlation between total haptic scores and the raw score on the verbal WISC (rp=0.43, n=62). Finally, test-retest reliability was good (rs=0.93, n=12; interval of one to two months). This new psychometric tool should prove useful to practitioners working with young people with impaired vision. Copyright © 2015 Elsevier Ltd. All rights reserved.
A novel method for objective vision testing in canine models of inherited retinal disease.
Gearhart, Patricia M; Gearhart, Chris C; Petersen-Jones, Simon M
2008-08-01
The use of canine models of retinal disease in the development of therapeutic strategies for inherited retinal disorders is a growing area of research. To evaluate accurately the success of potential vision-enhancing treatments, reliable methods for objectively assessing visual function in canine models is necessary. A simple vision-testing device was constructed that consisted of a junction box with four exit tunnels. Dogs were placed in the junction box and given one vision-based choice for exit. The first-choice tunnel and time to exit were recorded and analyzed. Two canine models of retinal disease with distinct molecular defects, a null mutation in the gene encoding the alpha subunit of rod cyclic GMP phosphodiesterase (PDE6A), and a null mutation in the gene encoding a retinal pigment epithelium-specific protein (RPE65) were tested and compared to those in unaffected dogs. With the use of bright light versus dim red light, the test differentiated between unaffected dogs and dogs affected with either mutation with a high degree of certainty. The white-light intensity series showed a significantly different performance between the unaffected and affected dogs. A significant difference in performance was detected between the dogs with each mutation. The results indicate that this novel canine vision-testing method is an accurate and sensitive means of distinguishing between unaffected dogs and dogs affected with two different forms of inherited retinal disease and should be useful as a means of assessing response to therapy in future studies.
Vijaya, Lingam; George, Ronnie; Asokan, Rashima; Velumuri, Lokapavani; Ramesh, Sathyamangalam Ve
2014-04-01
To evaluate the prevalence and causes of low vision and blindness in an urban south Indian population. Population-based cross-sectional study. Exactly 3850 subjects aged 40 years and above from Chennai city were examined at a dedicated facility in the base hospital. All subjects had a complete ophthalmic examination that included best-corrected visual acuity. Low vision and blindness were defined using World Health Organization (WHO) criteria. The influence of age, gender, literacy, and occupation was assessed using multiple logistic regression. Chi-square test, t-test, and multivariate analysis were used. Of the 4800 enumerated subjects, 3850 subjects (1710 males, 2140 females) were examined (response rate, 80.2%). The prevalence of blindness was 0.85% (95% CI 0.6-1.1%) and was positively associated with age and illiteracy. Cataract was the leading cause (57.6%) and glaucoma was the second cause (16.7%) for blindness. The prevalence of low vision was 2.9% (95% CI 2.4-3.4%) and visual impairment (blindness + low vision) was 3.8% (95% CI 3.2-4.4%). The primary causes for low vision were refractive errors (68%) and cataract (22%). In this urban population based study, cataract was the leading cause for blindness and refractive error was the main reason for low vision.
Adaptation of a Developmental Test to Accommodate Young Children with Low Vision
ERIC Educational Resources Information Center
Ferreira, Viviana; Albuquerque, Cristina P.
2017-01-01
Introduction: This study analyzed the effects of accommodations for children with low vision in the Griffiths Mental Development Scales--Extended Revised (GMDS-ER). Methods: The sample comprised 25 children with low vision and chronological ages between 28 and 76 months. There were two assessment phases: in the first, the Griffiths Scales were…
INCREASED VISUAL BEHAVIOR IN LOW VISION CHILDREN.
ERIC Educational Resources Information Center
BARRAGA, NATALIE
TEN PAIRS OF BLIND CHILDREN AGED SIX TO 13 YEARS WHO HAD SOME VISION WERE MATCHED BY PRETEST SCORES ON A TEST OF VISUAL DISCRIMINATION. A CRITERION GROUP, DESIGNATED THE PRINT COMPARISON GROUP, HAD SLIGHLY HIGHER RECORDED DISTANCE ACUITIES AND USED VISION AS THE PRIMARY MEANS OF LEARNING. PAIRS OF EXPERIMENTAL SUBJECTS DAILY RECEIVED 45 MINUTES OF…
Physiologic and Endocrine Correlates of Overweightness in African Americans and Caucasians
2009-03-27
aerobic graded exercise test (VO2 max test ) on a treadmill ( Philips StressVue Exercise Stress Testing System with Trackmaster Full Vision Inc...Pediatrics, 118 (6), 2434-42. Wang, J., Thornton, J.C., Bari, S., Williamson, B., Gallagher, D., Heymsfield, S.B., Horlick, M., Kotler , D...on a treadmill ( Philips StressVue Exercise Stress System, Trackmaster Full Vision Inc. Treadmill; Waltham, MA) to assess cardiovascular fitness. The
2001-03-01
detection or use by special forces in air-sea rescue operations. It is not the case that colour vision is improved and the use of the devices should be...situation. The tests were developed by clinicians for detecting pathologies. Only rarely do they bear any close relation to the tasks actually...examination procedures will certainly emerge, helped by microcomputing, the use of databases and, why not, Internet? iii la Vision des couleurs dans
Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.
Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen
2017-02-01
ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Molecular patterns of X chromosome-linked color vision genes among 134 men of European ancestry.
Drummond-Borg, M; Deeb, S S; Motulsky, A G
1989-01-01
We used Southern blot hybridization to study X chromosome-linked color vision genes encoding the apoproteins of red and green visual pigments in 134 unselected Caucasian men. One hundred and thirteen individuals (84.3%) had a normal arrangement of their color vision pigment genes. All had one red pigment gene; the number of green pigment genes ranged from one to five with a mode of two. The frequency of molecular genotypes indicative of normal color vision (84.3%) was significantly lower than had been observed in previous studies of color vision phenotypes. Color vision defects can be due to deletions of red or green pigment genes or due to formation of hybrid genes comprising portions of both red and green pigment genes [Nathans, J., Piantanida, T.P., Eddy, R.L., Shows, T.B., Jr., & Hogness, D.S. (1986) Science 232, 203-210]. Characteristic anomalous patterns were seen in 15 (11.2%) individuals: 7 (5.2%) had patterns characteristic of deuteranomaly (mild defect in green color perception), 2 (1.5%) had patterns characteristic of deuteranopia (severe defect in green color perception), and 6 (4.5%) had protan patterns (the red perception defects protanomaly and protanopia cannot be differentiated by current molecular methods). Previously undescribed hybrid gene patterns consisting of both green and red pigment gene fragments in addition to normal red and green genes were observed in another 6 individuals (4.5%). Only 2 of these patterns were considered as deuteranomalous. Thus, DNA testing detected anomalous color vision pigment genes at a higher frequency than expected from phenotypic color vision tests. Some color vision gene arrays associated with hybrid genes are likely to mediate normal color vision. Images PMID:2915991
Comparative visual performance with monofocal and multifocal intraocular lenses
Gundersen, Kjell Gunnar; Potvin, Richard
2013-01-01
Background To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. Methods Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a single diagnostic visit between 3 and 8 months after second-eye surgery. Lenses tested included an aspheric monofocal and two apodized diffractive multifocal IOLs with slightly different design parameters. A total of 94 patients were evaluated. Results Subjects with the ReSTOR® +2.5 D IOL had better near and intermediate vision than those subjects with a monofocal IOL. Intermediate vision was similar to, and near vision slightly lower than, that of subjects with a ReSTOR® +3.0 D IOL implanted. The preferred reading distance was slightly farther out for the +2.5 D relative to the +3.0 D lens, and farthest for the monofocal. Visual acuity at the preferred reading distance was equal with the two multifocal IOLs and significantly worse with the monofocal IOL. Quality of vision measures were highest with the monofocal IOL and similar between the two multifocal IOLs. Conclusion The data indicate that the ReSTOR +2.5 D IOL provided good intermediate and functional near vision for patients who did not want to accept a higher potential for visual disturbances associated with the ReSTOR +3.0 D IOL, but wanted more near vision than a monofocal IOL generally provides. Quality of vision was not significantly different between the multifocal IOLs, but patient self-selection for each lens type may have been a factor. PMID:24143064
Learning prosthetic vision: a virtual-reality study.
Chen, Spencer C; Hallum, Luke E; Lovell, Nigel H; Suaning, Gregg J
2005-09-01
Acceptance of prosthetic vision will be heavily dependent on the ability of recipients to form useful information from such vision. Training strategies to accelerate learning and maximize visual comprehension would need to be designed in the light of the factors affecting human learning under prosthetic vision. Some of these potential factors were examined in a visual acuity study using the Landolt C optotype under virtual-reality simulation of prosthetic vision. Fifteen normally sighted subjects were tested for 10-20 sessions. Potential learning factors were tested at p < 0.05 with regression models. Learning was most evident across-sessions, though 17% of sessions did express significant within-session trends. Learning was highly concentrated toward a critical range of optotype sizes, and subjects were less capable in identifying the closed optotype (a Landolt C with no gap, forming a closed annulus). Training for implant recipients should target these critical sizes and the closed optotype to extend the limit of visual comprehension. Although there was no evidence that image processing affected overall learning, subjects showed varying personal preferences.
Accuracy improvement in a calibration test bench for accelerometers by a vision system
DOE Office of Scientific and Technical Information (OSTI.GOV)
D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it
2016-06-28
A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behaviormore » if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.« less
A Modified Protocol for Color Vision Screening Using Ishihara.
Chorley, Adrian C
2015-08-01
The Ishihara plates are commonly used as an initial occupational screening test for color vision. While effective at detecting red-green deficiencies, the color deficient subject can learn the test using different techniques. Some medical standards such as the European Aviation Safety Agency (EASA) require plate randomization and apply a stricter pass/fail requirement than suggested by Ishihara. This has been reported to increase the false positive rate up to ∼50%. Two modifications to the Ishihara protocol are investigated. These involved allowing subjects a second attempt where one or two reading errors were made and the presentation of rotated Ishihara plates. A reduction of false positive rate to 5.9% was found. Correct identification of certain rotated Ishihara plates was not affected. By using a modified Ishihara protocol, fewer color normal subjects would require unnecessary advanced color vision examination. Further, additional safeguards would be in place to ensure that no subject with a color vision deficiency could pass the Ishihara test.
The correlation between visual acuity and color vision as an indicator of the cause of visual loss.
Almog, Yehoshua; Nemet, Arie
2010-06-01
To explore the correlation between visual acuity (VA) and color vision and to establish a guide for the diagnosis of the cause of visual loss based on this correlation. Retrospective comparative evaluation of a diagnostic test. A total of 259 patients with visual impairment caused by 1 of 4 possible disease categories were included. Patients were divided into 4 groups according to the etiology of visual loss: 1) optic neuropathies, 2) macular diseases, 3) media opacities, and 4) amblyopia. The best-corrected VA was established and a standard Ishihara 15 color plates was tested and correlated to the VA in every group separately. Correlation between the VA and the color vision along the different etiologies was evaluated. Frequency of each combination of color vision and VA in every disease category was established. VA is correlated with color vision in all 4 disease categories. For the same degree of VA loss, patients with optic neuropathy are most likely and patients with amblyopia are the least expected to have a significant color vision loss. Patients with optic neuropathy had considerably worse average color vision (6.7/15) compared to patients in the other 3 disease categories: 11.1/15 (macular diseases), 13.2/15 (media opacities), and 13.4/15 (amblyopia). Diseases of the optic nerve affect color vision earlier and more profoundly than other diseases. When the cause of visual loss is uncertain, the correlation between the severity of color vision and VA loss can imply the possible etiology of the visual loss. Copyright 2010 Elsevier Inc. All rights reserved.
Poor Vision, Functioning, and Depressive Symptoms: A Test of the Activity Restriction Model
ERIC Educational Resources Information Center
Bookwala, Jamila; Lawson, Brendan
2011-01-01
Purpose: This study tested the applicability of the activity restriction model of depressed affect to the context of poor vision in late life. This model hypothesizes that late-life stressors contribute to poorer mental health not only directly but also indirectly by restricting routine everyday functioning. Method: We used data from a national…
Color vision defects in adrenomyeloneuropathy.
Sack, G H; Raven, M B; Moser, H W
1989-01-01
The relationship between abnormal color vision and adrenomyeloneuropathy (AMN) was investigated in 27 AMN patients and 31 age-matched controls by using the Farnsworth-Munsell 100 Hue test. Twelve (44%) of 27 patients showed test scores significantly above normal. The axes of bipolarity determined by the testing differed widely between the patients with abnormal scores, compatible with the notion that different alterations in visual pigment genes occur in different AMN kindreds. These observations confirm our earlier impression that the frequency of abnormal color vision is increased in these kindreds, and it supports our contentions that (1) AMN (and its companion, adrenoleukodystrophy) are very closely linked to the visual pigment loci at Xq28 and (2) this proximity might provide the opportunity to observe contiguous gene defects. PMID:2729274
Knowledge-based machine vision systems for space station automation
NASA Technical Reports Server (NTRS)
Ranganath, Heggere S.; Chipman, Laure J.
1989-01-01
Computer vision techniques which have the potential for use on the space station and related applications are assessed. A knowledge-based vision system (expert vision system) and the development of a demonstration system for it are described. This system implements some of the capabilities that would be necessary in a machine vision system for the robot arm of the laboratory module in the space station. A Perceptics 9200e image processor, on a host VAXstation, was used to develop the demonstration system. In order to use realistic test images, photographs of actual space shuttle simulator panels were used. The system's capabilities of scene identification and scene matching are discussed.
Real Time Target Tracking Using Dedicated Vision Hardware
NASA Astrophysics Data System (ADS)
Kambies, Keith; Walsh, Peter
1988-03-01
This paper describes a real-time vision target tracking system developed by Adaptive Automation, Inc. and delivered to NASA's Launch Equipment Test Facility, Kennedy Space Center, Florida. The target tracking system is part of the Robotic Application Development Laboratory (RADL) which was designed to provide NASA with a general purpose robotic research and development test bed for the integration of robot and sensor systems. One of the first RADL system applications is the closing of a position control loop around a six-axis articulated arm industrial robot using a camera and dedicated vision processor as the input sensor so that the robot can locate and track a moving target. The vision system is inside of the loop closure of the robot tracking system, therefore, tight throughput and latency constraints are imposed on the vision system that can only be met with specialized hardware and a concurrent approach to the processing algorithms. State of the art VME based vision boards capable of processing the image at frame rates were used with a real-time, multi-tasking operating system to achieve the performance required. This paper describes the high speed vision based tracking task, the system throughput requirements, the use of dedicated vision hardware architecture, and the implementation design details. Important to the overall philosophy of the complete system was the hierarchical and modular approach applied to all aspects of the system, hardware and software alike, so there is special emphasis placed on this topic in the paper.
ERIC Educational Resources Information Center
Francis, Leslie John
The purpose of this study was to provide an in-depth analysis of vision-screening programs in relation to their efficacy, appropriateness, and feasibility for public school use. Twenty-two vision-screening programs were analyzed for reliability, validity, efficiency of identification and referral cost, and required testing time. Findings are that…
The Evolution of the Snellen E to the Blackbird. (Blackbird Preschool Vision Screening Program).
ERIC Educational Resources Information Center
Sato-Viacrucis, Kiyo
Comparison of a variety of vision screening methods used with preschool children led to modification of the standard Snellen E test called the Blackbird Vision Screening System. An instructional story using an "E-bird" was developed to teach children the various possible positions of the E. The visual confusion caused by the chart was…
Impaired colour vision in workers exposed to organic solvents: A systematic review.
Betancur-Sánchez, A M; Vásquez-Trespalacios, E M; Sardi-Correa, C
2017-01-01
To evaluate recent evidence concerning the relationship between the exposure to organic solvents and the impairment of colour vision. A bibliographic search was conducted for scientific papers published in the last 15 years, in the LILACS, PubMed, Science Direct, EBSCO, and Cochrane databases that included observational studies assessing the relationship between impairment in colour vision and exposure to organic solvents. Eleven studies were selected that were performed on an economically active population and used the Lanthony D-15 desaturated test (D-15d), measured the exposure to organic solvents, and included unexposed controls. It was found that there is a statistically significant relationship between the exposure to organic solvents and the presence of an impairment in colour vision. The results support the hypothesis that exposure to organic solvents could induce acquired dyschromatopsia. The evaluation of colour vision with the D-15d test is simple and sensitive for diagnosis. More studies need to be conducted on this subject in order to better understand the relationship between impaired colour vision and more severe side effects caused by this exposure. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
Prevalence of non-strabismic anomalies of binocular vision in Tamil Nadu: report 2 of BAND study.
Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; George, Ronnie; Swaminathan, Meenakshi; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar
2017-11-01
Population-based studies on the prevalence of non-strabismic anomalies of binocular vision in ethnic Indians are more than two decades old. Based on indigenous normative data, the BAND (Binocular Vision Anomalies and Normative Data) study aims to report the prevalence of non-strabismic anomalies of binocular vision among school children in rural and urban Tamil Nadu. This population-based, cross-sectional study was designed to estimate the prevalence of non-strabismic anomalies of binocular vision in the rural and urban population of Tamil Nadu. In four schools, two each in rural and urban arms, 920 children in the age range of seven to 17 years were included in the study. Comprehensive binocular vision assessment was done for all children including evaluation of vergence and accommodative systems. In the first phase of the study, normative data of parameters of binocular vision were assessed followed by prevalence estimates of non-strabismic anomalies of binocular vision. The mean and standard deviation of the age of the sample were 12.7 ± 2.7 years. The prevalence of non-strabismic anomalies of binocular vision in the urban and rural arms was found to be 31.5 and 29.6 per cent, respectively. Convergence insufficiency was the most prevalent (16.5 and 17.6 per cent in the urban and rural arms, respectively) among all the types of non-strabismic anomalies of binocular vision. There was no gender predilection and no statistically significant differences were observed between the rural and urban arms in the prevalence of non-strabismic anomalies of binocular vision (Z-test, p > 0.05). The prevalence of non-strabismic anomalies of binocular vision was found to be higher in the 13 to 17 years age group (36.2 per cent) compared to seven to 12 years (25.1 per cent) (Z-test, p < 0.05). Non-strabismic binocular vision anomalies are highly prevalent among school children and the prevalence increases with age. With increasing near visual demands in the higher grades, these anomalies could significantly impact the reading efficiency of children. Thus, it is recommended that screening for anomalies of binocular vision should be integrated into the conventional vision screening protocol. © 2016 Optometry Australia.
Evaluation of Candidate Millimeter Wave Sensors for Synthetic Vision
NASA Technical Reports Server (NTRS)
Alexander, Neal T.; Hudson, Brian H.; Echard, Jim D.
1994-01-01
The goal of the Synthetic Vision Technology Demonstration Program was to demonstrate and document the capabilities of current technologies to achieve safe aircraft landing, take off, and ground operation in very low visibility conditions. Two of the major thrusts of the program were (1) sensor evaluation in measured weather conditions on a tower overlooking an unused airfield and (2) flight testing of sensor and pilot performance via a prototype system. The presentation first briefly addresses the overall technology thrusts and goals of the program and provides a summary of MMW sensor tower-test and flight-test data collection efforts. Data analysis and calibration procedures for both the tower tests and flight tests are presented. The remainder of the presentation addresses the MMW sensor flight-test evaluation results, including the processing approach for determination of various performance metrics (e.g., contrast, sharpness, and variability). The variation of the very important contrast metric in adverse weather conditions is described. Design trade-off considerations for Synthetic Vision MMW sensors are presented.
Improved Airplane Windshields to Provide Vision in Stormy Weather
NASA Technical Reports Server (NTRS)
Clay, William C
1935-01-01
This report presents the results of wind tunnel tests to determine possible improvements in the design of airplane windshields, particularly with respect to the pilot's vision from the cabin in stormy weather.
Apfelbaum, Henry; Pelah, Adar; Peli, Eli
2007-01-01
Virtual reality locomotion simulators are a promising tool for evaluating the effectiveness of vision aids to mobility for people with low vision. This study examined two factors to gain insight into the verisimilitude requirements of the test environment: the effects of treadmill walking and the suitability of using controls as surrogate patients. Ten "tunnel vision" patients with retinitis pigmentosa (RP) were tasked with identifying which side of a clearly visible obstacle their heading through the virtual environment would lead them, and were scored both on accuracy and on their distance from the obstacle when they responded. They were tested both while walking on a treadmill and while standing, as they viewed a scene representing progress through a shopping mall. Control subjects, each wearing a head-mounted field restriction to simulate the vision of a paired patient, were also tested. At wide angles of approach, controls and patients performed with a comparably high degree of accuracy, and made their choices at comparable distances from the obstacle. At narrow angles of approach, patients' accuracy increased when walking, while controls' accuracy decreased. When walking, both patients and controls delayed their decisions until closer to the obstacle. We conclude that a head-mounted field restriction is not sufficient for simulating tunnel vision, but that the improved performance observed for walking compared to standing suggests that a walking interface (such as a treadmill) may be essential for eliciting natural perceptually-guided behavior in virtual reality locomotion simulators.
Ahmadian, Lohrasb; Massof, Robert
2008-09-01
A retrospective case-matched study designed to compare patients with diabetic retinopathy (DR) and other ocular diseases, managed in a low-vision clinic, in four different types of functional vision. Reading, mobility, visual motor, and visual information processing were measured in the patients (n = 114) and compared with those in patients with other ocular diseases (n = 114) matched in sex, visual acuity (VA), general health status, and age, using the Activity Inventory as a Rasch-scaled measurement tool. Binocular distance visual acuity was categorized as normal (20/12.5-20/25), near normal (20/32-20/63), moderate (20/80-20/160), severe (20/200-20/400), profound (20/500-20/1000), and total blindness (20/1250 to no light perception). Both Wilcoxon matched pairs signed rank test and the sign test of matched pairs were used to compare estimated functional vision measures between DR cases and controls. Cases ranged in age from 19 to 90 years (mean age, 67.5), and 59% were women. The mean visual acuity (logMar scale) was 0.7. Based on the Wilcoxon signed rank test analyses and after adjusting the probability for multiple comparisons, there was no statistically significant difference (P > 0.05) between patients with DR and control subjects in any of four functional visions. Furthermore, diabetic retinopathy patients did not differ (P > 0.05) from their matched counterparts in goal-level vision-related functional ability and total visual ability. Visual impairment in patients with DR appears to be a generic and non-disease-specific outcome that can be explained mainly by the end impact of the disease in the patients' daily lives and not by the unique disease process that results in the visual impairment.
Price, David A; Price, Marianne O; Lopez, Amanda; Price, Francis W
2016-08-01
To assess changes in color discernment after Descemet membrane endothelial keratoplasty (DMEK) in patients with Fuchs endothelial corneal dystrophy (FECD). In this prospective, single-center study, the study group was composed of 26 patients with FECD, aged 46 to 85 years, who underwent DMEK as a single surgical procedure; 24 (92%) had pseudophakic and 2 (8%) had phakic eyes. The patients completed a computerized Farnsworth-Munsell 100-hue color vision test before and 1 month after DMEK. A control group of 14 subjects, aged 57 to 85 years, was tested 1 month after cataract surgery. The median number of errors made by patients who had undergone DMEK on the color vision test improved from 64 (range 24-124) before surgery to 48 (range 10-120) after surgery (P = 0.0053). The post-DMEK scores in the 24 patients with pseudophakic eyes (median = 48, range = 10-120) were comparable to those of an age-matched control group of patients with cataract without corneal abnormalities (median = 53, range = 4-104, P = 0.88). The improvement in color vision was not correlated with the amount of improvement in best corrected visual acuity (r = -0.02, P = 0.91) or with the reduction in central pachymetry (r = -0.08, P = 0.71) after DMEK. Consistent with spontaneous comments from some patients with FECD that colors appear more vivid after DMEK, a comparison of pre- and postoperative color vision scores showed that color discernment usually improved after DMEK (81%). The lack of correlation between color vision improvement and pachymetry reduction leads us to hypothesize that color vision improvement may relate to removal of the guttae associated with FECD.
Quality of vision in refractive and cataract surgery, indirect measurers: review article.
Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob
2013-01-01
Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.
Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.
Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E
2018-01-01
Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.
Comparing performance on the MNREAD iPad application with the MNREAD acuity chart
Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E.
2018-01-01
Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials. PMID:29351351
Comparison of tests of accommodation for computer users.
Kolker, David; Hutchinson, Robert; Nilsen, Erik
2002-04-01
With the increased use of computers in the workplace and at home, optometrists are finding more patients presenting with symptoms of Computer Vision Syndrome. Among these symptomatic individuals, research supports that accommodative disorders are the most common vision finding. A prepresbyopic group (N= 30) and a presbyopic group (N = 30) were selected from a private practice. Assignment to a group was determined by age, accommodative amplitude, and near visual acuity with their distance prescription. Each subject was given a thorough vision and ocular health examination, then administered several nearpoint tests of accommodation at a computer working distance. All the tests produced similar results in the presbyopic group. For the prepresbyopic group, the tests yielded very different results. To effectively treat symptomatic VDT users, optometrists must assess the accommodative system along with the binocular and refractive status. For presbyopic patients, all nearpoint tests studied will yield virtually the same result. However, the method of testing accommodation, as well as the test stimulus presented, will yield significantly different responses for prepresbyopic patients. Previous research indicates that a majority of patients prefer the higher plus prescription yielded by the Gaussian image test.
Badami, Rokhsareh; Mahmoudi, Sahar; Baluch, Bahman
2016-12-01
The presented study was aimed at identifying for the first time the influence of sports vision exercises on fundamental motor skills and cognitive skills of 7- to 10-year-old developmental dyslexic Persian children. A pretest-posttest quasi-experimental study was conducted. The statistical population of this study was 7- to 10-year-old dyslexic children referring to two centres of learning disorder in the city of Isfahan. Twenty two of these children were selected using available and purposive sampling from the statistical population and were randomly assigned into two groups of experimental and control. The former (experimental group) participated in sports vision exercise courses for 12 weeks (3 one hr sessions per week) and the latter (control group) continued their routine daily activities during the exercise. Before the beginning and at the end of the exercise, Gardner's test of visual perception test - revised and Dehkhoda's reading skills test was administered to both groups. The results showed that the sports vision exercises increases motor skills, visual perceptual skills and reading skills in developmental dyslexic children. Based on the results of the presented study it was concluded that sports vision exercises can be used for fundamental and cognitive skills of developmental dyslexic children.
On the performances of computer vision algorithms on mobile platforms
NASA Astrophysics Data System (ADS)
Battiato, S.; Farinella, G. M.; Messina, E.; Puglisi, G.; Ravì, D.; Capra, A.; Tomaselli, V.
2012-01-01
Computer Vision enables mobile devices to extract the meaning of the observed scene from the information acquired with the onboard sensor cameras. Nowadays, there is a growing interest in Computer Vision algorithms able to work on mobile platform (e.g., phone camera, point-and-shot-camera, etc.). Indeed, bringing Computer Vision capabilities on mobile devices open new opportunities in different application contexts. The implementation of vision algorithms on mobile devices is still a challenging task since these devices have poor image sensors and optics as well as limited processing power. In this paper we have considered different algorithms covering classic Computer Vision tasks: keypoint extraction, face detection, image segmentation. Several tests have been done to compare the performances of the involved mobile platforms: Nokia N900, LG Optimus One, Samsung Galaxy SII.
Prevalence and causes of low vision and blindness in an urban population: The Chennai Glaucoma Study
Vijaya, Lingam; George, Ronnie; Asokan, Rashima; Velumuri, Lokapavani; Ramesh, Sathyamangalam Ve
2014-01-01
Aim: To evaluate the prevalence and causes of low vision and blindness in an urban south Indian population. Settings and Design: Population-based cross-sectional study. Exactly 3850 subjects aged 40 years and above from Chennai city were examined at a dedicated facility in the base hospital. Materials and Methods: All subjects had a complete ophthalmic examination that included best-corrected visual acuity. Low vision and blindness were defined using World Health Organization (WHO) criteria. The influence of age, gender, literacy, and occupation was assessed using multiple logistic regression. Statistical Analysis: Chi-square test, t-test, and multivariate analysis were used. Results: Of the 4800 enumerated subjects, 3850 subjects (1710 males, 2140 females) were examined (response rate, 80.2%). The prevalence of blindness was 0.85% (95% CI 0.6–1.1%) and was positively associated with age and illiteracy. Cataract was the leading cause (57.6%) and glaucoma was the second cause (16.7%) for blindness. The prevalence of low vision was 2.9% (95% CI 2.4–3.4%) and visual impairment (blindness + low vision) was 3.8% (95% CI 3.2–4.4%). The primary causes for low vision were refractive errors (68%) and cataract (22%). Conclusions: In this urban population based study, cataract was the leading cause for blindness and refractive error was the main reason for low vision. PMID:23619490
Robotic space simulation integration of vision algorithms into an orbital operations simulation
NASA Technical Reports Server (NTRS)
Bochsler, Daniel C.
1987-01-01
In order to successfully plan and analyze future space activities, computer-based simulations of activities in low earth orbit will be required to model and integrate vision and robotic operations with vehicle dynamics and proximity operations procedures. The orbital operations simulation (OOS) is configured and enhanced as a testbed for robotic space operations. Vision integration algorithms are being developed in three areas: preprocessing, recognition, and attitude/attitude rates. The vision program (Rice University) was modified for use in the OOS. Systems integration testing is now in progress.
Temporal multiplexing with adaptive optics for simultaneous vision
Papadatou, Eleni; Del Águila-Carrasco, Antonio J.; Marín-Franch, Iván; López-Gil, Norberto
2016-01-01
We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and −2.5 D (near vision). Different bifocal designs, including toric and combinations of spherical aberration, were simulated and assessed objectively. We found that typical corneal aberrations of a 60-year-old subject changes the shape of objective through-focus curves of a perfect bifocal lens. This methodology can be used to investigate subjective visual performance for different multifocal contact or intraocular lens designs. PMID:27867718
Behavioural evidence of colour vision in free flying stingless bees.
Spaethe, J; Streinzer, M; Eckert, J; May, S; Dyer, A G
2014-06-01
Colour vision was first demonstrated with behavioural experiments in honeybees 100 years ago. Since that time a wealth of quality physiological data has shown a highly conserved set of trichromatic colour receptors in most bee species. Despite the subsequent wealth of behavioural research on honeybees and bumblebees, there currently is a relative dearth of data on stingless bees, which are the largest tribe of the eusocial bees comprising of more than 600 species. In our first experiment we tested Trigona cf. fuscipennis, a stingless bee species from Costa Rica in a field setting using the von Frisch method and show functional colour vision. In a second experiment with these bees, we use a simultaneous colour discrimination test designed for honeybees to enable a comparative analysis of relative colour discrimination. In a third experiment, we test in laboratory conditions Tetragonula carbonaria, an Australian stingless bee species using a similar simultaneous colour discrimination test. Both stingless bee species show relatively poorer colour discrimination compared to honeybees and bumblebees; and we discuss the value of being able to use these behavioural methods to efficiently extend our current knowledge of colour vision and discrimination in different bee species.
Simulation Test of a Head-Worn Display with Ambient Vision Display for Unusual Attitude Recovery
NASA Technical Reports Server (NTRS)
Arthur, Jarvis (Trey) J., III; Nicholas, Stephanie N.; Shelton, Kevin J.; Ballard, Kathryn; Prinzel, Lawrence J., III; Ellis, Kyle E.; Bailey, Randall E.; Williams, Steven P.
2017-01-01
Head-Worn Displays (HWDs) are envisioned as a possible equivalent to a Head-Up Display (HUD) in commercial and general aviation. A simulation experiment was conducted to evaluate whether the HWD can provide an equivalent or better level of performance to a HUD in terms of unusual attitude recognition and recovery. A prototype HWD was tested with ambient vision capability which were varied (on/off) as an independent variable in the experiment testing for attitude awareness. The simulation experiment was conducted in two parts: 1) short unusual attitude recovery scenarios where the aircraft is placed in an unusual attitude and a single-pilot crew recovered the aircraft; and, 2) a two-pilot crew operating in a realistic flight environment with "off-nominal" events to induce unusual attitudes. The data showed few differences in unusual attitude recognition and recovery performance between the tested head-down, head-up, and head-worn display concepts. The presence and absence of ambient vision stimulation was inconclusive. The ergonomic influences of the head-worn display, necessary to implement the ambient vision experimentation, may have influenced the pilot ratings and acceptance of the concepts.
Gil-Pagés, Macarena; Stiles, Robert J; Parks, Christopher A; Neier, Steven C; Radulovic, Maja; Oliveros, Alfredo; Ferrer, Alejandro; Reed, Brendan K; Wilton, Katelynn M; Schrum, Adam G
2013-08-23
There is significant interest in the generation of improved assays to clearly identify experimental mice possessing functional vision, a property that could qualify mice for inclusion in behavioral and neuroscience studies. Widely employed current methods rely on mouse responses to visual cues in assays of reflexes, depth perception, or cognitive memory. However, commonly assessed mouse reflexes can sometimes be ambiguous in their expression, while depth perception assays are sometimes confounded by variation in anxiety responses and exploratory conduct. Furthermore, in situations where experimental groups vary in their cognitive memory capacity, memory assays may not be ideal for assessing differences in vision. We have optimized a non-invasive behavioral assay that relies on an untrained, innate response to identify individual experimental mice possessing functional vision: slow angled-descent forepaw grasping (SLAG). First, we verified that SLAG performance depends on vision and not olfaction. Next, all members of an age-ranged cohort of 158 C57BL/6 mice (57 wild-type, 101 knockout, age range 44-241 days) were assessed for functional vision using the SLAG test without training or conditioning. Subjecting the population to a second innate behavioral test, Dark Chamber preference, corroborated that the functional vision assessment of SLAG was valid. We propose that the SLAG assay is immediately useful to quickly and clearly identify experimental mice possessing functional vision. SLAG is based on a behavioral readout with a significant innate component with no requirement for training. This will facilitate the selection of mice of known sighted status in vision-dependent experiments that focus on other types of behavior, neuroscience, and/or cognitive memory.
Impact of correcting visual impairment and low vision in deaf-mute students in Pune, India.
Gogate, Parikshit; Bhusan, Shashi; Ray, Shantanu; Shinde, Amit
2016-12-01
The aim of this study was to evaluate visual acuity and vision function before and after providing spectacles and low vision devices (LVDs) in deaf-mute students. Schools for deaf-mute in West Maharashtra. Hearing-impaired children in all special schools in Pune district underwent detailed visual acuity testing (with teachers' help), refraction, external ocular examination, and fundoscopy. Students with refractive errors and low vision were provided with spectacles and LVD. The LV Prasad-Functional Vision Questionnaire consisting of twenty items was administered to each subject before and after providing spectacles, LVDs. Wilcoxon matched-pairs signed-ranks test. 252/929 (27.1%) students had a refractive error. 794 (85.5%) were profound deaf. Two-hundred and fifty students were dispensed spectacles and LVDs. Mean LogMAR visual acuity before introduction of spectacles and LVDs were 0.33 ± 0.36 which improved to 0.058 (P < 0.0001) after intervention. It was found that difference in functional vision pre- and post-intervention was statistically significant (P < 0.0001) for questions 1-19. The most commonly reported difficulties were for performing distance task like reading the bus destination (58.7%), making out the bus number (51.1%), copying from blackboard (47.7%), and seeing whether somebody is waving hand from across the road (45.5%). In response to question number 20, 57.4% of students felt that their vision was much worse than their friend's vision, which was reduced to 17.6% after dispensing spectacles and LVDs. Spectacle and LVD reduced visual impairment and improved vision function in deaf-mute students, augmenting their ability to negotiate in and out of school.
Chang, Shih-Tsun; Liu, Yen-Hsiu; Lee, Jiahn-Shing; See, Lai-Chu
2015-09-01
The effect of correcting static vision on sports vision is still not clear. To examine whether sports vision (depth perception [DP], dynamic visual acuity [DVA], eye movement [EM], peripheral vision [PV], and momentary vision [MV],) were different among soft tennis adolescent athletes with normal vision (Group A), with refractive error and corrected with (Group B) and without eyeglasses (Group C). A cross-section study was conducted. Soft tennis athletes aged 10-13 who played softball tennis for 2-5 years, and who were without any ocular diseases and without visual training for the past 3 months were recruited. DPs were measured in an absolute deviation (mm) between a moving rod and fixing rod (approaching at 25 mm/s, receding at 25 mm/s, approaching at 50 mm/s, receding at 50 mm/s) using electric DP tester. A smaller deviation represented better DP. DVA, EM, PV, and MV were measured on a scale from 1 (worse) to 10 (best) using ATHLEVISION software. Chi-square test and Kruskal-Wallis test was used to compare the data among the three study groups. A total of 73 athletes (37 in Group A, 8 in Group B, 28 in Group C) were enrolled in this study. All four items of DP showed significant difference among the three study groups (P = 0.0051, 0.0004, 0.0095, 0.0021). PV displayed significant difference among the three study groups (P = 0.0044). There was no significant difference in DVA, EM, and MV among the three study groups. Significant better DP and PV were seen among soft tennis adolescent athletes with normal vision than those with refractive error regardless whether they had eyeglasses corrected. On the other hand, DVA, EM, and MV were similar among the three study groups.
2013-01-01
Background There is significant interest in the generation of improved assays to clearly identify experimental mice possessing functional vision, a property that could qualify mice for inclusion in behavioral and neuroscience studies. Widely employed current methods rely on mouse responses to visual cues in assays of reflexes, depth perception, or cognitive memory. However, commonly assessed mouse reflexes can sometimes be ambiguous in their expression, while depth perception assays are sometimes confounded by variation in anxiety responses and exploratory conduct. Furthermore, in situations where experimental groups vary in their cognitive memory capacity, memory assays may not be ideal for assessing differences in vision. Results We have optimized a non-invasive behavioral assay that relies on an untrained, innate response to identify individual experimental mice possessing functional vision: slow angled-descent forepaw grasping (SLAG). First, we verified that SLAG performance depends on vision and not olfaction. Next, all members of an age-ranged cohort of 158 C57BL/6 mice (57 wild-type, 101 knockout, age range 44–241 days) were assessed for functional vision using the SLAG test without training or conditioning. Subjecting the population to a second innate behavioral test, Dark Chamber preference, corroborated that the functional vision assessment of SLAG was valid. Conclusions We propose that the SLAG assay is immediately useful to quickly and clearly identify experimental mice possessing functional vision. SLAG is based on a behavioral readout with a significant innate component with no requirement for training. This will facilitate the selection of mice of known sighted status in vision-dependent experiments that focus on other types of behavior, neuroscience, and/or cognitive memory. PMID:23971729
Evaluation of ‘vision screening’ program for three to six-year-old children in the Republic of Iran
Khandekar, Rajiv; Parast, Noa; Arabi, Ashraf
2009-01-01
Background: Since 1996, vision screening of three to six-year-old children is conducted every year in Iran. We present outcomes of project review held in August 2006. Materials and Methods: Kindergarten teachers examined vision by using Snellen's illiterate ‘E’ chart. They used torchlight to detect strabismus. On a repeat test, if either eye had vision <20/30, the child was referred to the optometrist. A pediatric ophthalmologist examined and managed children with strabismus or amblyopia. Provincial managers supervised the screening program. The evaluator team assessed the coverage, yield, quality and feasibility, and cost-effectiveness of vision screening, as well as magnitude of amblyopia, and its risk factors. Result: In 2005, 1.4 million (67%) children were examined in all provinces of Iran. Opticians examined 90,319 (61%) children with defective vision that were referred to them. The prevalence of uncorrected refractive error, strabismus and amblyopia was 3.82% (95% CI 3.79 – 3.85), 0.39% (95% CI 0.38 – 0.40) and 1.25% (95% CI 1.24 – 1.26) respectively. Validity test of 7,768 children had a sensitivity of 74.5% (95% CI 72.7 – 76.3) and specificity of 97.2% (95% CI 96.7 – 97.7). The cost of amblyopia screening was US $ 1.5 per child. While the cost of screening and treating one child with amblyopia was US $ 245. Conclusion: A review of the vision screening of children in Iran showed it with screening and useful exercise and had a yield of 1:21. The coverage of vision screening was low and the management of children with amblyopia, low vision and refractive error needed strengthening. PMID:19861745
Evaluation of 'vision screening' program for three to six-year-old children in the Republic of Iran.
Khandekar, Rajiv; Parast, Noa; Arabi, Ashraf
2009-01-01
Since 1996, vision screening of three to six-year-old children is conducted every year in Iran. We present outcomes of project review held in August 2006. Kindergarten teachers examined vision by using Snellen's illiterate 'E' chart. They used torchlight to detect strabismus. On a repeat test, if either eye had vision < 20/30, the child was referred to the optometrist. A pediatric ophthalmologist examined and managed children with strabismus or amblyopia. Provincial managers supervised the screening program. The evaluator team assessed the coverage, yield, quality and feasibility, and cost-effectiveness of vision screening, as well as magnitude of amblyopia, and its risk factors. In 2005, 1.4 million (67%) children were examined in all provinces of Iran. Opticians examined 90,319 (61%) children with defective vision that were referred to them. The prevalence of uncorrected refractive error, strabismus and amblyopia was 3.82% (95% CI 3.79 - 3.85), 0.39% (95% CI 0.38 - 0.40) and 1.25% (95% CI 1.24 - 1.26) respectively. Validity test of 7,768 children had a sensitivity of 74.5% (95% CI 72.7 - 76.3) and specificity of 97.2% (95% CI 96.7 - 97.7). The cost of amblyopia screening was US $ 1.5 per child. While the cost of screening and treating one child with amblyopia was US $ 245. A review of the vision screening of children in Iran showed it with screening and useful exercise and had a yield of 1:21. The coverage of vision screening was low and the management of children with amblyopia, low vision and refractive error needed strengthening.
Currie, Zanna; Bhan, Archana; Pepper, Irene
2000-01-01
Objectives To assess the ability of patients with binocular 6/9 or 6/12 vision on the Snellen chart (Snellen acuity) to read a number plate at 20.5 m (the required standard for driving) and to determine how health professionals advise such patients about driving. Design Prospective study of patients and postal questionnaire to healthcare professionals. Subjects 50 patients with 6/9 vision and 50 with 6/12 vision and 100 general practitioners, 100 optometrists or opticians, and 100 ophthalmologists. Setting Ophthalmology outpatient clinics in Sheffield. Main outcome measures Ability to read a number plate at 20.5 m and health professionals' advice about driving on the basis of visual acuity. Results 26% of patients with 6/9 vision failed the number plate test, and 34% with 6/12 vision passed it. Of the general practitioners advising patients with 6/9 vision, 76% said the patients could drive, 13% said they should not drive, and 11% were unsure. Of the general practitioners advising patients with 6/12 vision, 21% said the patients could drive, 54% said they should not drive, and 25% were unsure. The level of acuity at which optometrists, opticians, and ophthalmologists would advise drivers against driving ranged from 6/9−2 (ability to read all except two letters on the 6/9 line of the Snellen chart) to less than 6/18. Conclusions Snellen acuity is a poor predictor of an individual's ability to meet the required visual standard for driving. Patients with 6/9 vision or less should be warned that they may fail to meet this standard, but those with 6/12 vision should not be assumed to be below the standard. PMID:11039964
Color vision deficiency in a middle-aged population: the Shahroud Eye Study.
Jafarzadehpur, Ebrahim; Hashemi, Hassan; Emamian, Mohammad Hassan; Khabazkhoob, Mehdi; Mehravaran, Shiva; Shariati, Mohammad; Fotouhi, Akbar
2014-10-01
The aim of this study was to determine the prevalence of color vision defects in the middle-age population of Shahroud, Iran. We selected 6,311 people from the 40- to 64-year-old population through random cluster sampling. Color vision testing was performed with the Farnsworth D-15. Cases with similar and symmetric results in both eyes were classified as hereditary, and those with asymmetric results were considered acquired. Cases that did not conform to standard patterns were classified as unknown category. Of 5,190 respondents (response rate 82.2 %), 5,102 participants underwent the color vision test. Of these, 14.7 % (95 % confidence interval 13.7-15.6) had some type of color vision deficiency. Of the 2,157 male participants, 6.2 % were hereditary and 10.2 % were acquired and of the 2,945 female participants, 3.1 % were hereditary and 10 % were acquired. Hereditary color deficiencies were mostly of the deutan form (63.8 %), and acquired deficiencies were mostly tritan (66.1 %). The prevalence of hereditary and acquired color vision deficiency, as well as different types of red-green and blue-yellow color vision defects significantly increased with age (p < 0.001). In conclusion, the pattern of color vision defects among the middle-aged population of Shahroud was significantly different from that seen in the younger population. This could be due to changes associated with age, gender, medical and ocular conditions, and differences in race and environment. Thus, results of previous examinations and the overall health status should be considered before making any judgment about the status of color vision in middle-aged people.
A Study of the Effect of Letter Spacing on the Reading Speed of Young Readers with Low Vision
ERIC Educational Resources Information Center
McLeish, Eve
2007-01-01
The aims of this study were two-fold: firstly, to establish a method of applying consistent letter spacing to documents using MS Word, and secondly, to investigate the effect of increased letter spacing on the reading speeds of readers with low vision. Tests on 14 readers with low vision showed that increased letter spacing benefited their reading…
Visual Turing test for computer vision systems
Geman, Donald; Geman, Stuart; Hallonquist, Neil; Younes, Laurent
2015-01-01
Today, computer vision systems are tested by their accuracy in detecting and localizing instances of objects. As an alternative, and motivated by the ability of humans to provide far richer descriptions and even tell a story about an image, we construct a “visual Turing test”: an operator-assisted device that produces a stochastic sequence of binary questions from a given test image. The query engine proposes a question; the operator either provides the correct answer or rejects the question as ambiguous; the engine proposes the next question (“just-in-time truthing”). The test is then administered to the computer-vision system, one question at a time. After the system’s answer is recorded, the system is provided the correct answer and the next question. Parsing is trivial and deterministic; the system being tested requires no natural language processing. The query engine employs statistical constraints, learned from a training set, to produce questions with essentially unpredictable answers—the answer to a question, given the history of questions and their correct answers, is nearly equally likely to be positive or negative. In this sense, the test is only about vision. The system is designed to produce streams of questions that follow natural story lines, from the instantiation of a unique object, through an exploration of its properties, and on to its relationships with other uniquely instantiated objects. PMID:25755262
Bento-Torres, Natáli Valim Oliver; Rodrigues, Anderson Raiol; Côrtes, Maria Izabel Tentes; Bonci, Daniela Maria de Oliveira; Ventura, Dora Fix
2016-01-01
We have used the Farnsworth-Munsell 100-hue (FM 100) test and Mollon-Reffin (MR) test to evaluate the colour vision of 93 subjects, 30.4 ± 9.7 years old, who had red-green congenital colour vision deficiencies. All subjects lived in Belém (State of Pará, Brazil) and were selected by the State of Pará Traffic Department. Selection criteria comprised the absence of visual dysfunctions other than Daltonism and no history of systemic diseases that could impair the visual system performance. Results from colour vision deficient were compared with those from 127 normal trichromats, 29.3 ± 10.3 years old. For the MR test, measurements were taken around five points of the CIE 1976 colour space, along 20 directions irradiating from each point, in order to determine with high-resolution the corresponding colour discrimination ellipses (MacAdam ellipses). Three parameters were used to compare results obtained from different subjects: diameter of circle with same ellipse area, ratio between ellipse’s long and short axes, and ellipse long axis angle. For the FM 100 test, the parameters were: logarithm of the total number of mistakes and positions of mistakes in the FM diagram. Data were also simultaneously analysed in two or three dimensions as well as by using multidimensional cluster analysis. For the MR test, Mollon-Reffin Ellipse #3 (u’ = 0.225, v’ = 0.415) discriminated more efficiently than the other four ellipses between protans and deutans once it provided larger angular difference in the colour space between protan and deutan confusion lines. The MR test was more sensitive than the FM 100 test. It separated individuals by dysfunctional groups with greater precision, provided a more sophisticated quantitative analysis, and its use is appropriate for a more refined evaluation of different phenotypes of red-green colour vision deficiencies. PMID:27101124
Bento-Torres, Natáli Valim Oliver; Rodrigues, Anderson Raiol; Côrtes, Maria Izabel Tentes; Bonci, Daniela Maria de Oliveira; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima
2016-01-01
We have used the Farnsworth-Munsell 100-hue (FM 100) test and Mollon-Reffin (MR) test to evaluate the colour vision of 93 subjects, 30.4 ± 9.7 years old, who had red-green congenital colour vision deficiencies. All subjects lived in Belém (State of Pará, Brazil) and were selected by the State of Pará Traffic Department. Selection criteria comprised the absence of visual dysfunctions other than Daltonism and no history of systemic diseases that could impair the visual system performance. Results from colour vision deficient were compared with those from 127 normal trichromats, 29.3 ± 10.3 years old. For the MR test, measurements were taken around five points of the CIE 1976 colour space, along 20 directions irradiating from each point, in order to determine with high-resolution the corresponding colour discrimination ellipses (MacAdam ellipses). Three parameters were used to compare results obtained from different subjects: diameter of circle with same ellipse area, ratio between ellipse's long and short axes, and ellipse long axis angle. For the FM 100 test, the parameters were: logarithm of the total number of mistakes and positions of mistakes in the FM diagram. Data were also simultaneously analysed in two or three dimensions as well as by using multidimensional cluster analysis. For the MR test, Mollon-Reffin Ellipse #3 (u' = 0.225, v' = 0.415) discriminated more efficiently than the other four ellipses between protans and deutans once it provided larger angular difference in the colour space between protan and deutan confusion lines. The MR test was more sensitive than the FM 100 test. It separated individuals by dysfunctional groups with greater precision, provided a more sophisticated quantitative analysis, and its use is appropriate for a more refined evaluation of different phenotypes of red-green colour vision deficiencies.
Eye vision system using programmable micro-optics and micro-electronics
NASA Astrophysics Data System (ADS)
Riza, Nabeel A.; Amin, M. Junaid; Riza, Mehdi N.
2014-02-01
Proposed is a novel eye vision system that combines the use of advanced micro-optic and microelectronic technologies that includes programmable micro-optic devices, pico-projectors, Radio Frequency (RF) and optical wireless communication and control links, energy harvesting and storage devices and remote wireless energy transfer capabilities. This portable light weight system can measure eye refractive powers, optimize light conditions for the eye under test, conduct color-blindness tests, and implement eye strain relief and eye muscle exercises via time sequenced imaging. Described is the basic design of the proposed system and its first stage system experimental results for vision spherical lens refractive error correction.
Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima
2012-01-01
The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188
2007-01-01
Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881
TOXICITY TESTING IN THE 21ST CENTURY: A VISION AND A STRATEGY
Krewski, Daniel; Acosta, Daniel; Andersen, Melvin; Anderson, Henry; Bailar, John C.; Boekelheide, Kim; Brent, Robert; Charnley, Gail; Cheung, Vivian G.; Green, Sidney; Kelsey, Karl T.; Kerkvliet, Nancy I.; Li, Abby A.; McCray, Lawrence; Meyer, Otto; Patterson, Reid D.; Pennie, William; Scala, Robert A.; Solomon, Gina M.; Stephens, Martin; Yager, James; Zeise, Lauren
2015-01-01
With the release of the landmark report Toxicity Testing in the 21st Century: A Vision and a Strategy, the U.S. National Academy of Sciences, in 2007, precipitated a major change in the way toxicity testing is conducted. It envisions increased efficiency in toxicity testing and decreased animal usage by transitioning from current expensive and lengthy in vivo testing with qualitative endpoints to in vitro toxicity pathway assays on human cells or cell lines using robotic high-throughput screening with mechanistic quantitative parameters. Risk assessment in the exposed human population would focus on avoiding significant perturbations in these toxicity pathways. Computational systems biology models would be implemented to determine the dose-response models of perturbations of pathway function. Extrapolation of in vitro results to in vivo human blood and tissue concentrations would be based on pharmacokinetic models for the given exposure condition. This practice would enhance human relevance of test results, and would cover several test agents, compared to traditional toxicological testing strategies. As all the tools that are necessary to implement the vision are currently available or in an advanced stage of development, the key prerequisites to achieving this paradigm shift are a commitment to change in the scientific community, which could be facilitated by a broad discussion of the vision, and obtaining necessary resources to enhance current knowledge of pathway perturbations and pathway assays in humans and to implement computational systems biology models. Implementation of these strategies would result in a new toxicity testing paradigm firmly based on human biology. PMID:20574894
George, Stacey; Hayes, Allison; Chen, Celia; Crotty, Maria
2011-01-01
To explore the relationship between disability and functional measures with vision-specific quality of life (QoL) measures for people with hemianopia and stroke. The Behavioral Inattention Test (BIT) and the Mayo-Portland Adaptability Inventory (MPAI) were compared with scores on 2 vision-specific QoL measures, the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) and Veteran Low Vision Visual Function Questionnaire (VA LV VFQ-48). Rehabilitation hospitals in Adelaide, South Australia. Stroke patients (n = 24) with homonymous hemianopia. Most of the BIT and MPAI scores were significantly associated with the NEI VFQ-25 and VA LV VFQ-48 scores. Behavioral test scores of the BIT and the MPAI total score correlated with more aspects of the QoL measures than the other components of the BIT and the MPAI. BIT and MPAI measure constructs associated with QoL for people with hemianopia following stroke. Vision-specific QoL questionnaires can complement the functional instruments by identifying the domains of difficulty, based on the instrument's subscale, that can guide rehabilitation therapists to address the person's deficit.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-22
...''); Amistar Automation, Inc. (``Amistar'') of San Marcos, California; Techno Soft Systemnics, Inc. (``Techno..., the ALJ's construction of the claim terms ``test,'' ``match score surface,'' and ``gradient direction...
Quinn, Mark Kenneth; Spinosa, Emanuele; Roberts, David A
2017-07-25
Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.
Spinosa, Emanuele; Roberts, David A.
2017-01-01
Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access. PMID:28757553
Visual function and color vision in adults with Attention-Deficit/Hyperactivity Disorder.
Kim, Soyeon; Chen, Samantha; Tannock, Rosemary
2014-01-01
Color vision and self-reported visual function in everyday life in young adults with Attention-Deficit/Hyperactivity Disorder (ADHD) were investigated. Participants were 30 young adults with ADHD and 30 controls matched for age and gender. They were tested individually and completed the Visual Activities Questionnaire (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) and A Quick Test of Cognitive Speed (AQT). The ADHD group reported significantly more problems in 4 of 8 areas on the VAQ: depth perception, peripheral vision, visual search and visual processing speed. Further analyses of VAQ items revealed that the ADHD group endorsed more visual problems associated with driving than controls. Color perception difficulties on the FMT were restricted to the blue spectrum in the ADHD group. FMT and AQT results revealed slower processing of visual stimuli in the ADHD group. A comprehensive investigation of mechanisms underlying visual function and color vision in adults with ADHD is warranted, along with the potential impact of these visual problems on driving performance. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Command History OPNAV 5750-1 Fiscal Year 2004
2006-05-04
highly capable facilities including three hyperbaric 2 chambers, anechoic chambers, auditory and vision laboratories, closed atmosphere test room...3 Hyperbaric Chambers (1 Saturation) • 1000m3 Anechoic Chamber • 140m3 Reverberant Chamber • 10 Audio Testing Booths • Vision Research...Using Hand-Held Personal Digital Assistants (PDAs) in a Hyperbaric Environment and the PDA-based Submarine Escape and Rescue Calculator and
Synthetic Vision Technology Demonstration. Volume 4. Appendices
1993-12-01
Synthetic Vision System and where advanced miaoebaro. tehnology would make signditcan oiprovements in capgwy or poduction cost. 2-6 SVSTDISIED Program Plan...achievement. 4. Determination of the pilot (test subject) mix and the test repetition needed to assure reasonable confidence In the results. 5...will contain the following elements: 1. Description - statement of what is to be accomplished. 2. Initial Conditions - items which must be accomplished
Color vision tests comparison: Farnsworth D-15 versus Lanthony D-15
NASA Astrophysics Data System (ADS)
Szmigiel, Marta; Geniusz, Malwina; Geniusz, Maciej K.
2017-09-01
Disorder of color vision in humans is the inability to perceive differences between some or all of the colors that are normally perceived by others. Color blindness is usually a birth defect, a genetically determined. For this reason it is much more common in men than women. This paper presents the results of the test FarnsworthD-15 and Lanthony D-15 on a group of volunteers, both adults and children. The study was conducted to compare the results of both tests.
NASA Technical Reports Server (NTRS)
Christian, John A.; Patangan, Mogi; Hinkel, Heather; Chevray, Keiko; Brazzel, Jack
2012-01-01
The Orion Multi-Purpose Crew Vehicle is a new spacecraft being designed by NASA and Lockheed Martin for future crewed exploration missions. The Vision Navigation Sensor is a Flash LIDAR that will be the primary relative navigation sensor for this vehicle. To obtain a better understanding of this sensor's performance, the Orion relative navigation team has performed both flight tests and ground tests. This paper summarizes and compares the performance results from the STS-134 flight test, called the Sensor Test for Orion RelNav Risk Mitigation (STORRM) Development Test Objective, and the ground tests at the Space Operations Simulation Center.
Impairment of color vision in aircraft maintenance workers.
Guest, Maya; D'Este, Catherine; Attia, John; Boggess, May; Brown, Anthony; Tavener, Meredith; Gibson, Richard; Gardner, Ian; Harrex, Warren; Ross, James
2011-10-01
The purpose of the study was to examine possible persisting effects to color vision in a group from the Royal Australian Air Force who had exposure to formulations containing neurotoxins during F-111 fuel tank maintenance, relative to two contemporaneous comparison groups. Color vision was tested in 512 exposed personnel, 458 technical-trade comparisons, and 330 non-technical comparisons using the Ishihara test plates and the Lanthony D-15 Desaturated Color disk arrangement test. Participants were excluded if they failed the Ishihara test as this indicates congenital color blindness. From the Lanthony results, the type of color deficient vision (CDV) was diagnosed, and additionally, the Bowman's color confusion index (CCI) was calculated. Regression models were used to examine whether there was an association between color vision deficiencies and F-111 fuel tank maintenance, adjusting for possible confounders. The CCI ranged from 1 to 2.8 (median 1.2, quartiles 1.1, 1.4) in the 2,600 eyes tested. Forty five percent of all participants had blue-yellow CDV in at least one eye. Deficiencies of this nature are caused by environmental exposures. Logistic regression demonstrated statistically significant differences in CCI category in the exposed group versus technical group (odds ratio 1.7: 95% CI 1.3-2.0) and a blue-yellow confusion in the exposed group versus technical group (odds ratio 1.4: 95% CI 1.1-1.7). No differences were observed between the exposed group and the non-technical group. The results indicate reduced color discrimination among the exposed subjects compared to one of two control groups. The findings may be due to previous exposure to solvents among the air force personnel.
Military Vision Research Program
2011-07-01
accomplishments emanating from this research . • 3 novel computer-based tasks have been developed that measure visual distortions • These tests are based...10-1-0392 TITLE: Military Vision Research Program PRINCIPAL INVESTIGATOR: Dr. Darlene Dartt...CONTRACTING ORGANIZATION: The Schepens Eye Research
Advanced helmet vision system (AHVS) integrated night vision helmet mounted display (HMD)
NASA Astrophysics Data System (ADS)
Ashcraft, Todd W.; Atac, Robert
2012-06-01
Gentex Corporation, under contract to Naval Air Systems Command (AIR 4.0T), designed the Advanced Helmet Vision System to provide aircrew with 24-hour, visor-projected binocular night vision and HMD capability. AHVS integrates numerous key technologies, including high brightness Light Emitting Diode (LED)-based digital light engines, advanced lightweight optical materials and manufacturing processes, and innovations in graphics processing software. This paper reviews the current status of miniaturization and integration with the latest two-part Gentex modular helmet, highlights the lessons learned from previous AHVS phases, and discusses plans for qualification and flight testing.
Visually induced self-motion sensation adapts rapidly to left-right reversal of vision
NASA Technical Reports Server (NTRS)
Oman, C. M.; Bock, O. L.
1981-01-01
Three experiments were conducted using 15 adult volunteers with no overt oculomotor or vestibular disorders. In all experiments, left-right vision reversal was achieved using prism goggles, which permitted a binocular field of vision subtending approximately 45 deg horizontally and 28 deg vertically. In all experiments, circularvection (CV) was tested before and immediately after a period of exposure to reversed vision. After one to three hours of active movement while wearing vision-reversing goggles, 10 of 15 (stationary) human subjects viewing a moving stripe display experienced a self-rotation illusion in the same direction as seen stripe motion, rather than in the opposite (normal) direction, demonstrating that the central neural pathways that process visual self-rotation cues can undergo rapid adaptive modification.
Wijeyekoon, Skanda; Kharicha, Kalpa; Iliffe, Steve
2015-09-01
To evaluate heuristics (rules of thumb) for recognition of undetected vision loss in older patients in primary care. Vision loss is associated with ageing, and its prevalence is increasing. Visual impairment has a broad impact on health, functioning and well-being. Unrecognised vision loss remains common, and screening interventions have yet to reduce its prevalence. An alternative approach is to enhance practitioners' skills in recognising undetected vision loss, by having a more detailed picture of those who are likely not to act on vision changes, report symptoms or have eye tests. This paper describes a qualitative technology development study to evaluate heuristics for recognition of undetected vision loss in older patients in primary care. Using a previous modelling study, two heuristics in the form of mnemonics were developed to aid pattern recognition and allow general practitioners to identify potential cases of unreported vision loss. These heuristics were then analysed with experts. Findings It was concluded that their implementation in modern general practice was unsuitable and an alternative solution should be sort.
Deficiency of adaptive control of the binocular coordination of saccades in strabismus.
Bucci, M P; Kapoula, Z; Eggert, T; Garraud, L
1997-10-01
Disconjugate (different in the two eyes) oculomotor adaptation is driven by the need to maintain binocular vision. Since binocular vision is deficient in strabismus, we wondered whether oculomotor disconjugate adaptive capabilities are deficient in such subjects. We studied eight adult subjects with constant, long-standing convergent strabismus of variable angles (4-30 prism D). No subject had severe amblyopia. Binocular vision was evaluated with stereoacuity tests. Two subjects had peripheral binocular vision and gross stereopsis; two other subjects had abnormal retinal correspondence and abnormal or pseudo gross stereopsis. In the other subjects binocular vision and stereopsis were absent. To stimulate disconjugate changes of saccades, subjects viewed for 20 min an image that was magnified in one eye (aniseikonia). Subjects with residual peripheral binocular vision and even subjects with pseudo or abnormal binocular vision showed disconjugate changes of the binocular coordination of their saccades; these changes reduced the disparity resulting from the aniseikonia. In contrast, for subjects without binocular vision the changes were not correlated with the disparity induced by the aniseikonia. Rather, these changes served to improve fixation of one or the other eye individually.
NASA Technical Reports Server (NTRS)
Wolbarsht, M. L.; White, C. W.; Anderson, W. B., Jr.
1973-01-01
The effects upon range of accommodation and color vision of reduced atmospheric pressure, at partial and complete elimination of nitrogen, of hypoxia, and of exposure for varying periods of time to restricted visual environment, have been studied alone or in various combinations. Measurements were made on the electroretinogram, the electrooculogram, and the diameter of the retinal vessels as an indicator of blood flow to the retina at the time of total elimination of nitrogen. An objective method was used to test range of accommodation. In the color vision test the flicker colors of a Benham's top were matched with a colorimeter.
Survey of Older Drivers’ Experiences with Florida’s Mandatory Vision Re-Screening Law for Licensure
McGwin, Gerald; McCartt, Anne T.; Braitman, Keli A.; Owsley, Cynthia
2008-01-01
Purpose To document the license renewal experiences of Florida drivers ages 80 and older who must pass a visual acuity test when renewing their driver’s license. Participants A random sample of Florida residents ages 80 and older whose driver’s licenses were scheduled to expire between January 1, 2004 and June 30, 2005 as identified by the Florida Department of Highway Safety and Motor Vehicles. Methods Study participants (n=1,242 drivers) were contacted via telephone and completed a survey regarding their experiences with the license renewal process. Results The majority (80.2%) of those eligible for license renewal reportedly attempted to do so and 88.0% succeeded the first time they tried. A large percentage of drivers (88%) who failed the vision test said they sought treatment, and 77.6% of drivers who reattempted renewal reportedly passed the test. About half of drivers who did not seek renewal said they thought they would fail the vision test. The majority of those choosing not to renew their license (99.5%) reported using transportation alternatives. Conclusions This Study suggests that the Florida vision screening re-licensure law is not a deterrent to seeking license renewal for the ≥80-year-old population. Furthermore, only a small percentage of Florida drivers ages ≥ 80 years and older reported that they failed the visual acuity screening test and were denied license renewal. PMID:18432496
A pseudoisochromatic test of color vision for human infants.
Mercer, Michele E; Drodge, Suzanne C; Courage, Mary L; Adams, Russell J
2014-07-01
Despite the development of experimental methods capable of measuring early human color vision, we still lack a procedure comparable to those used to diagnose the well-identified congenital and acquired color vision anomalies in older children, adults, and clinical patients. In this study, we modified a pseudoisochromatic test to make it more suitable for young infants. Using a forced choice preferential looking procedure, 216 3-to-23-mo-old babies were tested with pseudoisochromatic targets that fell on either a red/green or a blue/yellow dichromatic confusion axis. For comparison, 220 color-normal adults and 22 color-deficient adults were also tested. Results showed that all babies and adults passed the blue/yellow target but many of the younger infants failed the red/green target, likely due to the interaction of the lingering immaturities within the visual system and the small CIE vector distance within the red/green plate. However, older (17-23 mo) infants, color- normal adults and color-defective adults all performed according to expectation. Interestingly, performance on the red/green plate was better among female infants, well exceeding the expected rate of genetic dimorphism between genders. Overall, with some further modification, the test serves as a promising tool for the detection of early color vision anomalies in early human life. Copyright © 2014 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Datta, Poulomee; Talukdar, Joy
2017-01-01
This study investigated the influence of the support services on the test anxiety of students and/or their ability to submit assignments in each of the two disability groups, those with vision impairment and those with intellectual disability, who were placed in specialist and mainstream educational settings in South Australia. Interviews were…
Bali, Jatinder; Navin, Neeraj; Thakur, Bali Renu
2007-01-01
To study the knowledge, attitude and practices (KAP) towards computer vision syndrome prevalent in Indian ophthalmologists and to assess whether 'computer use by practitioners' had any bearing on the knowledge and practices in computer vision syndrome (CVS). A random KAP survey was carried out on 300 Indian ophthalmologists using a 34-point spot-questionnaire in January 2005. All the doctors who responded were aware of CVS. The chief presenting symptoms were eyestrain (97.8%), headache (82.1%), tiredness and burning sensation (79.1%), watering (66.4%) and redness (61.2%). Ophthalmologists using computers reported that focusing from distance to near and vice versa (P =0.006, chi2 test), blurred vision at a distance (P =0.016, chi2 test) and blepharospasm (P =0.026, chi2 test) formed part of the syndrome. The main mode of treatment used was tear substitutes. Half of ophthalmologists (50.7%) were not prescribing any spectacles. They did not have any preference for any special type of glasses (68.7%) or spectral filters. Computer-users were more likely to prescribe sedatives/anxiolytics (P = 0.04, chi2 test), spectacles (P = 0.02, chi2 test) and conscious frequent blinking (P = 0.003, chi2 test) than the non-computer-users. All respondents were aware of CVS. Confusion regarding treatment guidelines was observed in both groups. Computer-using ophthalmologists were more informed of symptoms and diagnostic signs but were misinformed about treatment modalities.
Normative values for a tablet computer-based application to assess chromatic contrast sensitivity.
Bodduluri, Lakshmi; Boon, Mei Ying; Ryan, Malcolm; Dain, Stephen J
2018-04-01
Tablet computer displays are amenable for the development of vision tests in a portable form. Assessing color vision using an easily accessible and portable test may help in the self-monitoring of vision-related changes in ocular/systemic conditions and assist in the early detection of disease processes. Tablet computer-based games were developed with different levels of gamification as a more portable option to assess chromatic contrast sensitivity. Game 1 was designed as a clinical version with no gaming elements. Game 2 was a gamified version of game 1 (added fun elements: feedback, scores, and sounds) and game 3 was a complete game with vision task nested within. The current study aimed to determine the normative values and evaluate repeatability of the tablet computer-based games in comparison with an established test, the Cambridge Colour Test (CCT) Trivector test. Normally sighted individuals [N = 100, median (range) age 19.0 years (18-56 years)] had their chromatic contrast sensitivity evaluated binocularly using the three games and the CCT. Games 1 and 2 and the CCT showed similar absolute thresholds and tolerance intervals, and game 3 had significantly lower values than games 1, 2, and the CCT, due to visual task differences. With the exception of game 3 for blue-yellow, the CCT and tablet computer-based games showed similar repeatability with comparable 95% limits of agreement. The custom-designed games are portable, rapid, and may find application in routine clinical practice, especially for testing younger populations.
Stephens, Martin L.; Barrow, Craig; Andersen, Melvin E.; Boekelheide, Kim; Carmichael, Paul L.; Holsapple, Michael P.; Lafranconi, Mark
2012-01-01
The U.S. National Research Council (NRC) report on “Toxicity Testing in the 21st century” calls for a fundamental shift in the way that chemicals are tested for human health effects and evaluated in risk assessments. The new approach would move toward in vitro methods, typically using human cells in a high-throughput context. The in vitro methods would be designed to detect significant perturbations to “toxicity pathways,” i.e., key biological pathways that, when sufficiently perturbed, lead to adverse health outcomes. To explore progress on the report’s implementation, the Human Toxicology Project Consortium hosted a workshop on 9–10 November 2010 in Washington, DC. The Consortium is a coalition of several corporations, a research institute, and a non-governmental organization dedicated to accelerating the implementation of 21st-century Toxicology as aligned with the NRC vision. The goal of the workshop was to identify practical and scientific ways to accelerate implementation of the NRC vision. The workshop format consisted of plenary presentations, breakout group discussions, and concluding commentaries. The program faculty was drawn from industry, academia, government, and public interest organizations. Most presentations summarized ongoing efforts to modernize toxicology testing and approaches, each with some overlap with the NRC vision. In light of these efforts, the workshop identified recommendations for accelerating implementation of the NRC vision, including greater strategic coordination and planning across projects (facilitated by a steering group), the development of projects that test the proof of concept for implementation of the NRC vision, and greater outreach and communication across stakeholder communities. PMID:21948868
Rodriguez-Carmona, Marisa; O'Neill-Biba, Matilda; Barbur, John L
2012-01-01
The Ishihara Test (IT) is arguably the most sensitive and commonly used color vision test within aviation and other occupational environments, but when no errors are allowed -20% of normal trichromats fail the test. The number of allowed errors varies in different occupations and sometimes within the same environment (such as aviation) in order to reflect the difficulties of the color-related tasks. The implicit assumption is that the plates can be ranked in order of difficulty. The principal aim of this study was to investigate whether appropriate "weights" can be attached to each IT plate to reflect the likelihood of producing a correct response. A second aim was to justify the use of color thresholds for quantifying the loss of red-green (RG) and yellow-blue (YB) chromatic sensitivity. We investigated 742 subjects (236 normals, 340 deutans, and 166 protans) using the first 25 plates of the 38-plate IT and measured RG chromatic sensitivity using the Color Assessment and Diagnosis (CAD) test. The IT error scores provided plate-specific "weights" which were used to calculate a Severity Index (SI) of color vision loss for each subject. Error scores, SI values, and CAD thresholds were measured and compared in each of the three subject groups. Color thresholds can provide a good measure of the severity of both RG and YB color vision loss. Neither the number of IT plates failed nor the SI value computed in this way can be used to determine reliably the severity of color vision loss.
Li, Yi; Chen, Yuren
2016-12-30
To make driving assistance system more humanized, this study focused on the prediction and assistance of drivers' perception-response time on mountain highway curves. Field tests were conducted to collect real-time driving data and driver vision information. A driver-vision lane model quantified curve elements in drivers' vision. A multinomial log-linear model was established to predict perception-response time with traffic/road environment information, driver-vision lane model, and mechanical status (last second). A corresponding assistance model showed a positive impact on drivers' perception-response times on mountain highway curves. Model results revealed that the driver-vision lane model and visual elements did have important influence on drivers' perception-response time. Compared with roadside passive road safety infrastructure, proper visual geometry design, timely visual guidance, and visual information integrality of a curve are significant factors for drivers' perception-response time.
Vision impairment and dual sensory problems in middle age
Dawes, Piers; Dickinson, Christine; Emsley, Richard; Bishop, Paul; Cruickshanks, Karen; Edmondson-Jones, Mark; McCormack, Abby; Fortnum, Heather; Moore, David R.; Norman, Paul; Munro, Kevin
2014-01-01
Purpose Vision and hearing impairments are known to increase in middle age. In this study we describe the prevalence of vision impairment and dual sensory impairment in UK adults aged 40 to 69 years in a very large and recently ascertained data set. The associations between vision impairment, age, sex, socioeconomic status, and ethnicity are reported. Methods This research was conducted using the UK Biobank Resource, with subsets of UK Biobank data analysed with respect to self-report of eye problems and glasses use. Better-eye visual acuity with habitually worn refractive correction was assessed with a logMAR chart (n = 116,682). Better-ear speech reception threshold was measured with an adaptive speech in noise test, the Digit Triplet Test (n = 164,770). Prevalence estimates were weighted with respect to UK 2001 Census data. Results Prevalence of mild visual impairment and low vision was estimated at 15.2% (95% CI 14.9–15.5%) and 0.9% (95% CI 0.8–1.0%), respectively. Use of glasses was 88.0% (95% CI 87.9–88.1%). The prevalence of dual sensory impairment was 3.1% (95% CI 3.0–3.2%) and there was a nine-fold increase in the prevalence of dual sensory problems between the youngest and oldest age groups. Older adults, those from low socioeconomic and ethnic minority backgrounds were most at risk for vision problems. Conclusions Mild vision impairment is common in middle aged UK adults, despite widespread use of spectacles. Possible barriers to optometric care for those from low socioeconomic and ethnic minority backgrounds may require attention. A higher than expected prevalence of dual impairment suggests that hearing and vision problems share common causes. Optometrists should consider screening for hearing problems, particularly among older adults. PMID:24888710
NASA Technical Reports Server (NTRS)
Decker, T. A.; Williams, R. E.; Kuether, C. L.; Logar, N. D.; Wyman-Cornsweet, D.
1975-01-01
A computer-operated binocular vision testing device was developed as one part of a system designed for NASA to evaluate the visual function of astronauts during spaceflight. This particular device, called the Mark 3 Haploscope, employs semi-automated psychophysical test procedures to measure visual acuity, stereopsis, phoria, fixation disparity, refractive state and accommodation/convergence relationships. Test procedures are self-administered and can be used repeatedly without subject memorization. The Haploscope was designed as one module of the complete NASA Vision Testing System. However, it is capable of stand-alone operation. Moreover, the compactness and portability of the Haploscope make possible its use in a broad variety of testing environments.
Dain, Stephen J; Casolin, Armand; Long, Jennifer
2015-02-01
The Farnsworth Lantern (FaLant) and the OPTEC 900 are nominated in the Commission Internationale de l'Éclairage (CIE) Color Vision Standard 2. Neither test uses the railway signal color code of red, yellow, and green, and only the OPTEC 900 is commercially available. The Railway LED Lantern Test (RLLT) is based on railway signaling practices in New South Wales, Australia, and is nominated in the Australian railway medical standard. The objective of this study is to compare the performance of the three lantern tests. The RLLT, FaLant, and OPTEC 900 were administered to 46 color vision-normal and 37 color vision-deficient (CVD) subjects. The pattern of errors on the RLLT was different from that of the FaLant and OPTEC 900. This may be accounted for, at least in part, by the different colors and the use of blank presentations in the RLLT. The three lanterns showed agreement in failing 21 and passing 6 of the CVD subjects (72.9%). The lanterns gave different results for 10 CVD subjects (27.9%): n = 5 passed only the RLLT and n = 3 passed only the FaLant; n = 1 failed only the FaLant and n = 1 failed only the RLLT. The overall failure rate by CVD for each lantern was 67.6% (RLLT), 73.0% (FaLant), and 78.4% (OPTEC 900). Despite the different construction principles, the pass/fail levels of the RLLT, FaLant, and OPTEC 900 are comparable and consistent with the performance of other lanterns listed by the CIE for Color Vision Standard 2. The RLLT may be a little easier to pass and is based on the signal color code used and actual signaling practice. We propose that the RLLT is also an appropriate lantern for CIE Color Vision Standard 2.
[The Performance Analysis for Lighting Sources in Highway Tunnel Based on Visual Function].
Yang, Yong; Han, Wen-yuan; Yan, Ming; Jiang, Hai-feng; Zhu, Li-wei
2015-10-01
Under the condition of mesopic vision, the spectral luminous efficiency function is shown as a series of curves. Its peak wavelength and intensity are affected by light spectrum, background brightness and other aspects. The impact of light source to lighting visibility could not be carried out via a single optical parametric characterization. The reaction time of visual cognition is regard as evaluating indexes in this experiment. Under the condition of different speed and luminous environment, testing visual cognition based on vision function method. The light sources include high pressure sodium, electrodeless fluorescent lamp and white LED with three kinds of color temperature (the range of color temperature is from 1 958 to 5 537 K). The background brightness value is used for basic section of highway tunnel illumination and general outdoor illumination, its range is between 1 and 5 cd x m(-)2. All values are in the scope of mesopic vision. Test results show that: under the same condition of speed and luminance, the reaction time of visual cognition that corresponding to high color temperature of light source is shorter than it corresponding to low color temperature; the reaction time corresponding to visual target in high speed is shorter than it in low speed. At the end moment, however, the visual angle of target in observer's visual field that corresponding to low speed was larger than it corresponding to high speed. Based on MOVE model, calculating the equivalent luminance of human mesopic vision, which is on condition of different emission spectrum and background brightness that formed by test lighting sources. Compared with photopic vision result, the standard deviation (CV) of time-reaction curve corresponding to equivalent brightness of mesopic vision is smaller. Under the condition of mesopic vision, the discrepancy between equivalent brightness of different lighting source and photopic vision, that is one of the main reasons for causing the discrepancy of visual recognition. The emission spectrum peak of GaN chip is approximate to the wave length peak of efficiency function in photopic vision. The lighting visual effect of write LED in high color temperature is better than it in low color temperature and electrodeless fluorescent lamp. The lighting visual effect of high pressure sodium is weak. Because of its peak value is around the Na+ characteristic spectra.
Gokce, Hasan Suat; Piskin, Bulent; Ceyhan, Dogan; Gokce, Sila Mermut; Arisan, Volkan
2010-03-01
The lighting conditions of the environment and visual deficiencies such as red-green color vision deficiency affect the clinical shade matching performance of dental professionals. The purpose of this study was to evaluate the shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants. Two sets of porcelain disc replicas of 16 shade guide tabs (VITA Lumin) were manufactured to exact L*a*b* values by using a colorimeter. Then these twin porcelain discs (13 mm x 2.4 mm) were mixed up and placed into a color-matching cabinet that standardized the lighting conditions for the observation tests. Normal and red-green color vision-deficient dental professionals were asked to match the 32 porcelain discs using standard artificial daylight D65 (high color temperature) and tungsten filament lamp light (T) (low color temperature) illuminants. The results were analyzed by repeated-measures ANOVA and paired and independent samples t tests for the differences between dental professionals and differences between the illuminants (alpha=.05). Regarding the sum of the correct shade match scores of all observations with both illuminants, the difference between normal vision and red-green color vision-deficient dental professional groups was not statistically significant (F=4.132; P=.054). However, the correct shade match scores of each group were significantly different for each illuminant (P<.005). The correct shade matching scores of normal color vision dental professionals were significantly higher with D65 illuminant (t=7.004; P<.001). Color matching scores of red-green color vision-deficient dental professionals (approximately 5.7 more pairs than with D65) were significantly higher with T illuminant (t=5.977; P<.001). CONCLUSIONS.: Within the limitations of this study, the shade matching performance of dental professionals was affected by color vision deficiency and the color temperature of the illuminant. The color vision-deficient group was notably unsuccessful with the D65 illuminant in shade matching. In contrast, there was a significant increase in the shade matching performance of the color vision-deficient group with T illuminant. The lower color temperature illuminant dramatically decreased the normal color vision groups' correct shade matching score. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Impact of confidence number on accuracy of the SureSight Vision Screener.
2010-02-01
To assess the relation between the confidence number provided by the Welch Allyn SureSight Vision Screener and screening accuracy, and to determine whether repeated testing to achieve a higher confidence number improves screening accuracy in pre-school children. Lay and nurse screeners screened 1452 children enrolled in the Vision in Preschoolers (VIP) Phase II Study. All children also underwent a comprehensive eye examination. By using statistical comparison of proportions, we examined sensitivity and specificity for detecting any ocular condition targeted for detection in the VIP study and conditions grouped by severity and by type (amblyopia, strabismus, significant refractive error, and unexplained decreased visual acuity) among children who had confidence numbers < or =4 (retest necessary), 5 (retest if possible), > or =6 (acceptable). Among the 687 (47.3%) children who had repeated testing by either lay or nurse screeners because of a low confidence number (<6) for one or both eyes in the initial testing, the same analyses were also conducted to compare results between the initial reading and repeated test reading with the highest confidence number in the same child. These analyses were based on the failure criteria associated with 90% specificity for detecting any VIP condition in VIP Phase II. A lower confidence number category were associated with higher sensitivity (0.71, 0.65, and 0.59 for < or =4, 5, and > or =6, respectively, p = 0.04) but no statistical difference in specificity (0.85, 0.85, and 0.91, p = 0.07) of detecting any VIP-targeted condition. Children with any VIP-targeted condition were as likely to be detected using the initial confidence number reading as using the higher confidence number reading from repeated testing. A higher confidence number obtained during screening with the SureSight Vision Screener is not associated with better screening accuracy. Repeated testing to reach the manufacturer's recommended minimum value is not helpful in pre-school vision screening.
Naidoo, Kovin S.; Ramson, Prasidh; Chinanayi, Farai; Zhuwau, Tom; Øverland, Lene
2015-01-01
Background Vision impairment, resulting in vision difficulties, is a leading cause of disability, and hence one of the key barriers for people to access education and employment, which may force them into poverty. Objectives The objective of this study was to determine the prevalence of self-reported vision difficulties as an indicator of vision impairment in economically disadvantaged regions in South Africa, and to examine the relationship between self-reported vision difficulties and socio-economic markers of poverty, namely, income, education and health service needs. Methods A cross-sectional study was conducted in economically disadvantaged districts to collect data from households on poverty and health, including vision difficulty. As visual acuity measurements were not conducted, the researchers used the term vision difficulty as an indicator of vision impairment. Data were collected from 27 districts (74 901 respondents). Logistic regression analysis and chi-square tests were used to determine bivariate relationships between variables and self-reported vision difficulty. Kernel density estimators were used for age, categorised by self-reported and not reported vision difficulty. Results Prevalence of self-reported vision difficulty was 11.2% (95% CI, 8.7% – 13.7%). More women (12.7%) compared to men (9.5%) self-reported vision difficulty (p < 0.01). Self-reported vision difficulty was higher (14.2%) for respondents that do not spend any money. A statistically significant relationship was found between the highest level of education and self-reporting of vision difficulty; as completed highest level of education increased, self-reporting of vision difficulty became lower (p < 0.01). A significantly higher prevalence of self-reported vision difficulty was found in respondents who are employed (p < 0.01), 17% (95% CI: 12.8% – 21.1%). Conclusion The evidence from this study suggests associations between socio-economic factors and vision difficulties that have a two-fold relationship (some factors such as education, and access to eye health services are associated with vision difficulty whilst vision difficulty may trap people in their current poverty or deepen their poverty status). The results are thus indicative of the need for further research in South Africa. PMID:28730022
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Bailey, Randall E.; Ellis, Kyle K. E.; Williams, Steven P.; Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Shelton, Kevin J.
2013-01-01
Synthetic Vision Systems and Enhanced Flight Vision System (SVS/EFVS) technologies have the potential to provide additional margins of safety for aircrew performance and enable operational improvements for low visibility operations in the terminal area environment with equivalent efficiency as visual operations. To meet this potential, research is needed for effective technology development and implementation of regulatory standards and design guidance to support introduction and use of SVS/EFVS advanced cockpit vision technologies in Next Generation Air Transportation System (NextGen) operations. A fixed-base pilot-in-the-loop simulation test was conducted at NASA Langley Research Center that evaluated the use of SVS/EFVS in NextGen low visibility approach and landing operations. Twelve crews flew approach and landing operations in a simulated NextGen Chicago O'Hare environment. Various scenarios tested the potential for using EFVS to conduct approach, landing, and roll-out operations in visibility as low as 1000 feet runway visual range (RVR). Also, SVS was tested to evaluate the potential for lowering decision heights (DH) on certain instrument approach procedures below what can be flown today. Expanding the portion of the visual segment in which EFVS can be used in lieu of natural vision from 100 feet above the touchdown zone elevation to touchdown and rollout in visibilities as low as 1000 feet RVR appears to be viable as touchdown performance was acceptable without any apparent workload penalties. A lower DH of 150 feet and/or possibly reduced visibility minima using SVS appears to be viable when implemented on a Head-Up Display, but the landing data suggests further study for head-down implementations.
Development of a vision-targeted health-related quality of life item measure
Slotkin, Jerry; McKean-Cowdin, Roberta; Lee, Paul; Owsley, Cynthia; Vitale, Susan; Varma, Rohit; Gershon, Richard; Hays, Ron D.
2013-01-01
Purpose To develop a vision-targeted health-related quality of life (HRQOL) measure for the NIH Toolbox for the Assessment of Neurological and Behavioral Function. Methods We conducted a review of existing vision-targeted HRQOL surveys and identified color vision, low luminance vision, distance vision, general vision, near vision, ocular symptoms, psychosocial well-being, and role performance domains. Items in existing survey instruments were sorted into these domains. We selected non-redundant items and revised them to improve clarity and to limit the number of different response options. We conducted 10 cognitive interviews to evaluate the items. Finally, we revised the items and administered them to 819 individuals to calibrate the items and estimate the measure’s reliability and validity. Results The field test provided support for the 53-item vision-targeted HRQOL measure encompassing 6 domains: color vision, distance vision, near vision, ocular symptoms, psychosocial well-being, and role performance. The domain scores had high levels of reliability (coefficient alphas ranged from 0.848 to 0.940). Validity was supported by high correlations between National Eye Institute Visual Function Questionnaire scales and the new-vision-targeted scales (highest values were 0.771 between psychosocial well-being and mental health, and 0.729 between role performance and role difficulties), and by lower mean scores in those groups self-reporting eye disease (F statistic with p < 0.01 for all comparisons except cataract with ocular symptoms, psychosocial well-being, and role performance scales). Conclusions This vision-targeted HRQOL measure provides a basis for comprehensive assessment of the impact of eye diseases and treatments on daily functioning and well-being in adults. PMID:23475688
Chang, Shih-Tsun; Liu, Yen-Hsiu; Lee, Jiahn-Shing; See, Lai-Chu
2015-01-01
Background: The effect of correcting static vision on sports vision is still not clear. Aim: To examine whether sports vision (depth perception [DP], dynamic visual acuity [DVA], eye movement [EM], peripheral vision [PV], and momentary vision [MV],) were different among soft tennis adolescent athletes with normal vision (Group A), with refractive error and corrected with (Group B) and without eyeglasses (Group C). Setting and Design: A cross-section study was conducted. Soft tennis athletes aged 10–13 who played softball tennis for 2–5 years, and who were without any ocular diseases and without visual training for the past 3 months were recruited. Materials and Methods: DPs were measured in an absolute deviation (mm) between a moving rod and fixing rod (approaching at 25 mm/s, receding at 25 mm/s, approaching at 50 mm/s, receding at 50 mm/s) using electric DP tester. A smaller deviation represented better DP. DVA, EM, PV, and MV were measured on a scale from 1 (worse) to 10 (best) using ATHLEVISION software. Statistical Analysis: Chi-square test and Kruskal–Wallis test was used to compare the data among the three study groups. Results: A total of 73 athletes (37 in Group A, 8 in Group B, 28 in Group C) were enrolled in this study. All four items of DP showed significant difference among the three study groups (P = 0.0051, 0.0004, 0.0095, 0.0021). PV displayed significant difference among the three study groups (P = 0.0044). There was no significant difference in DVA, EM, and MV among the three study groups. Conclusions: Significant better DP and PV were seen among soft tennis adolescent athletes with normal vision than those with refractive error regardless whether they had eyeglasses corrected. On the other hand, DVA, EM, and MV were similar among the three study groups. PMID:26632127
Considering the Influence of Nonadaptive Evolution on Primate Color Vision.
Jacobs, Rachel L; Bradley, Brenda J
2016-01-01
Color vision in primates is variable across species, and it represents a rare trait in which the genetic mechanisms underlying phenotypic variation are fairly well-understood. Research on primate color vision has largely focused on adaptive explanations for observed variation, but it remains unclear why some species have trichromatic or polymorphic color vision while others are red-green color blind. Lemurs, in particular, are highly variable. While some species are polymorphic, many closely-related species are strictly dichromatic. We provide the first characterization of color vision in a wild population of red-bellied lemurs (Eulemur rubriventer, Ranomafana National Park, Madagascar) with a sample size (87 individuals; NX chromosomes = 134) large enough to detect even rare variants (0.95 probability of detection at ≥ 3% frequency). By sequencing exon 5 of the X-linked opsin gene we identified opsin spectral sensitivity based on known diagnostic sites and found this population to be dichromatic and monomorphic for a long wavelength allele. Apparent fixation of this long allele is in contrast to previously published accounts of Eulemur species, which exhibit either polymorphic color vision or only the medium wavelength opsin. This unexpected result may represent loss of color vision variation, which could occur through selective processes and/or genetic drift (e.g., genetic bottleneck). To indirectly assess the latter scenario, we genotyped 55 adult red-bellied lemurs at seven variable microsatellite loci and used heterozygosity excess and M-ratio tests to assess if this population may have experienced a recent genetic bottleneck. Results of heterozygosity excess but not M-ratio tests suggest a bottleneck might have occurred in this red-bellied lemur population. Therefore, while selection may also play a role, the unique color vision observed in this population might have been influenced by a recent genetic bottleneck. These results emphasize the need to consider adaptive and nonadaptive mechanisms of color vision evolution in primates.
Considering the Influence of Nonadaptive Evolution on Primate Color Vision
Jacobs, Rachel L.; Bradley, Brenda J.
2016-01-01
Color vision in primates is variable across species, and it represents a rare trait in which the genetic mechanisms underlying phenotypic variation are fairly well-understood. Research on primate color vision has largely focused on adaptive explanations for observed variation, but it remains unclear why some species have trichromatic or polymorphic color vision while others are red-green color blind. Lemurs, in particular, are highly variable. While some species are polymorphic, many closely-related species are strictly dichromatic. We provide the first characterization of color vision in a wild population of red-bellied lemurs (Eulemur rubriventer, Ranomafana National Park, Madagascar) with a sample size (87 individuals; NX chromosomes = 134) large enough to detect even rare variants (0.95 probability of detection at ≥ 3% frequency). By sequencing exon 5 of the X-linked opsin gene we identified opsin spectral sensitivity based on known diagnostic sites and found this population to be dichromatic and monomorphic for a long wavelength allele. Apparent fixation of this long allele is in contrast to previously published accounts of Eulemur species, which exhibit either polymorphic color vision or only the medium wavelength opsin. This unexpected result may represent loss of color vision variation, which could occur through selective processes and/or genetic drift (e.g., genetic bottleneck). To indirectly assess the latter scenario, we genotyped 55 adult red-bellied lemurs at seven variable microsatellite loci and used heterozygosity excess and M-ratio tests to assess if this population may have experienced a recent genetic bottleneck. Results of heterozygosity excess but not M-ratio tests suggest a bottleneck might have occurred in this red-bellied lemur population. Therefore, while selection may also play a role, the unique color vision observed in this population might have been influenced by a recent genetic bottleneck. These results emphasize the need to consider adaptive and nonadaptive mechanisms of color vision evolution in primates. PMID:26959829
2013-01-01
Background Dual sensory loss (DSL) has a negative impact on health and wellbeing and its prevalence is expected to increase due to demographic aging. However, specialized care or rehabilitation programs for DSL are scarce. Until now, low vision rehabilitation does not sufficiently target concurrent impairments in vision and hearing. This study aims to 1) develop a DSL protocol (for occupational therapists working in low vision rehabilitation) which focuses on optimal use of the senses and teaches DSL patients and their communication partners to use effective communication strategies, and 2) describe the multicenter parallel randomized controlled trial (RCT) designed to test the effectiveness and cost-effectiveness of the DSL protocol. Methods/design To develop a DSL protocol, literature was reviewed and content was discussed with professionals in eye/ear care (interviews/focus groups) and DSL patients (interviews). A pilot study was conducted to test and confirm the DSL protocol. In addition, a two-armed international multi-center RCT will evaluate the effectiveness and cost-effectiveness of the DSL protocol compared to waiting list controls, in 124 patients in low vision rehabilitation centers in the Netherlands and Belgium. Discussion This study provides a treatment protocol for rehabilitation of DSL within low vision rehabilitation, which aims to be a valuable addition to the general low vision rehabilitation care. Trial registration Netherlands Trial Register (NTR) identifier: NTR2843 PMID:23941667
Martínez-Bueso, Pau; Moyà-Alcover, Biel
2014-01-01
Observation is recommended in motor rehabilitation. For this reason, the aim of this study was to experimentally test the feasibility and benefit of including mirror feedback in vision-based rehabilitation systems: we projected the user on the screen. We conducted a user study by using a previously evaluated system that improved the balance and postural control of adults with cerebral palsy. We used a within-subjects design with the two defined feedback conditions (mirror and no-mirror) with two different groups of users (8 with disabilities and 32 without disabilities) using usability measures (time-to-start (T s) and time-to-complete (T c)). A two-tailed paired samples t-test confirmed that in case of disabilities the mirror feedback facilitated the interaction in vision-based systems for rehabilitation. The measured times were significantly worse in the absence of the user's own visual feedback (T s = 7.09 (P < 0.001) and T c = 4.48 (P < 0.005)). In vision-based interaction systems, the input device is the user's own body; therefore, it makes sense that feedback should be related to the body of the user. In case of disabilities the mirror feedback mechanisms facilitated the interaction in vision-based systems for rehabilitation. Results recommends developers and researchers use this improvement in vision-based motor rehabilitation interactive systems. PMID:25295310
Vision-based navigation in a dynamic environment for virtual human
NASA Astrophysics Data System (ADS)
Liu, Yan; Sun, Ji-Zhou; Zhang, Jia-Wan; Li, Ming-Chu
2004-06-01
Intelligent virtual human is widely required in computer games, ergonomics software, virtual environment and so on. We present a vision-based behavior modeling method to realize smart navigation in a dynamic environment. This behavior model can be divided into three modules: vision, global planning and local planning. Vision is the only channel for smart virtual actor to get information from the outside world. Then, the global and local planning module use A* and D* algorithm to find a way for virtual human in a dynamic environment. Finally, the experiments on our test platform (Smart Human System) verify the feasibility of this behavior model.
Essentials of photometry for clinical electrophysiology of vision.
McCulloch, Daphne L; Hamilton, Ruth
2010-08-01
Electrophysiological testing of the visual system requires familiarity with photometry. This technical note outlines the concepts of photometry with a focus on information relevant to clinical ERG and VEP testing. Topics include photometric quantities, consideration of pupil size, specification of brief extended flash stimuli, and the influence of the spectral composition of visual stimuli. Standard units and terms are explained in the context of the ISCEV standards and guidelines for clinical electrophysiology of vision.
Color vision testing with a computer graphics system: preliminary results.
Arden, G; Gündüz, K; Perry, S
1988-06-01
We report a method for computer enhancement of color vision tests. In our graphics system 256 colors are selected from a much larger range and displayed on a screen divided into 768 x 288 pixels. Eight-bit digital-to-analogue converters drive a high quality monitor with separate inputs to the red, green, and blue amplifiers and calibrated gun chromaticities. The graphics are controlled by a PASCAL program written for a personal computer, which calculates the values of the red, green, and blue signals and specifies them in Commité Internationale d'Eclairage X, Y, and Z fundamentals, so changes in chrominance occur without changes in luminance. The system for measuring color contrast thresholds with gratings is more than adequate in normal observers. In patients with mild retinal damage in whom other tests of visual function are normal, this method of testing color vision shows specific increases in contrast thresholds along tritan color-confusion lines. By the time the Hardy-Rand-Rittler and Farnsworth-Munsell 100-hue tests disclose abnormalities, gross defects in color contrast threshold can be seen with our system.
Hyvärinen, Lea
2007-01-01
Visual assessment of deaf persons presents a challenge to the ophthalmologist and the optometrist. At the time they want to measure visual function, the interpreter uses visual communication, competing for the patient's attention. Important rules of good assessment of visual functioning include taking turns and giving the interpreter sufficient time to convey the questions related to each test. This has implications for audiologists working with this population as well. Communication should be tailored to the varying needs of people who may have long-standing deafness and good sign language, may have lost their hearing at an advanced age and have limited or no sign language, or may be young persons or children who have congenital or progressive loss of hearing combined with congenital or progressive vision loss. Individuals with sudden hearing and vision loss, as well as those with intellectual disabilities and limited language, are particularly challenging groups for the assessment of vision and require special communication skills for ophthalmologists and audiologists. The ophthalmologist usually knows the nature of vision changes typical of disorders that the patient has. For the clinical follow-up of a condition, a few measurements are usually taken. For a comprehensive assessment of visual functioning for rehabilitation and education, many more measurements, observations, and questions are needed so that vision for communication, orientation in the environment, and performance of near-vision tasks can be reported and the effects of the environment can be evaluated. Testing should cover ocular disorders and vision loss caused by brain damage. PMID:18003866
Mobility performance in glaucoma.
Turano, K A; Rubin, G S; Quigley, H A
1999-11-01
To determine whether glaucoma affects mobility performance and whether there is a relationship between mobility performance and stage of disease as estimated from vision-function measures. The mobility performance of 47 glaucoma subjects was compared with that of 47 normal-vision subjects who were of similar age. Mobility performance was assessed by the time required to complete an established travel path and the number of mobility incidents. The subjective assessment of falling and fear of falling were also compared. Vision function was assessed by measures of visual acuity, contrast sensitivity, monocular automated threshold perimetry, and suprathreshold; binocular visual fields were assessed with the Esterman test. The glaucoma subjects walked on average 10% more slowly than did the normal-vision subjects. The number of people who experienced bumps, stumbles, or orientation problems was almost twice as high in the glaucoma group than the normal-vision group, but the difference did not reach statistical significance. The difference between groups also was not significant with respect to the number of people who reported falling in the past year (38% for the glaucoma group and 30% for the normal-vision group) or a fear of falling (28% for the glaucoma group and 23% for the normal-vision group). The visual fields assessed with a Humphrey 24-2 test were more highly correlated with walking speed in glaucoma than the visual fields scored by the Esterman scale or than visual acuity or contrast sensitivity. Glaucoma is associated with a modest decrease in mobility performance. Walking speed decreases with severity of the disease as estimated by threshold perimetry.
Pedersen, Hilde R; Hagen, Lene A; Landsend, Erlend C S; Gilson, Stuart J; Utheim, Øygunn A; Utheim, Tor P; Neitz, Maureen; Baraas, Rigmor C
2018-04-01
To assess color vision and its association with retinal structure in persons with congenital aniridia. We included 36 persons with congenital aniridia (10-66 years), and 52 healthy, normal trichromatic controls (10-74 years) in the study. Color vision was assessed with Hardy-Rand-Rittler (HRR) pseudo-isochromatic plates (4th ed., 2002); Cambridge Color Test and a low-vision version of the Color Assessment and Diagnosis test (CAD-LV). Cone-opsin genes were analyzed to confirm normal versus congenital color vision deficiencies. Visual acuity and ocular media opacities were assessed. The central 30° of both eyes were imaged with the Heidelberg Spectralis OCT2 to grade the severity of foveal hypoplasia (FH, normal to complete: 0-4). Five participants with aniridia had cone opsin genes conferring deutan color vision deficiency and were excluded from further analysis. Of the 31 with aniridia and normal opsin genes, 11 made two or more red-green (RG) errors on HRR, four of whom also made yellow-blue (YB) errors; one made YB errors only. A total of 19 participants had higher CAD-LV RG thresholds, of which eight also had higher CAD-LV YB thresholds, than normal controls. In aniridia, the thresholds were higher along the RG than the YB axis, and those with a complete FH had significantly higher RG thresholds than those with mild FH (P = 0.038). Additional increase in YB threshold was associated with secondary ocular pathology. Arrested foveal formation and associated alterations in retinal processing are likely to be the primary reason for impaired red-green color vision in aniridia.
High-Resolution Adaptive Optics Test-Bed for Vision Science
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilks, S C; Thomspon, C A; Olivier, S S
2001-09-27
We discuss the design and implementation of a low-cost, high-resolution adaptive optics test-bed for vision research. It is well known that high-order aberrations in the human eye reduce optical resolution and limit visual acuity. However, the effects of aberration-free eyesight on vision are only now beginning to be studied using adaptive optics to sense and correct the aberrations in the eye. We are developing a high-resolution adaptive optics system for this purpose using a Hamamatsu Parallel Aligned Nematic Liquid Crystal Spatial Light Modulator. Phase-wrapping is used to extend the effective stroke of the device, and the wavefront sensing and wavefrontmore » correction are done at different wavelengths. Issues associated with these techniques will be discussed.« less
A Comparison of the AVS-9 and the Panoramic Night Vision Goggles During Rotorcraft Hover and Landing
NASA Technical Reports Server (NTRS)
Szoboszlay, Zoltan; Haworth, Loran; Simpson, Carol
2000-01-01
A flight test was conducted to assess any differences in pilot-vehicle performance and pilot opinion between the use of a current generation night vision goggle (the AVS-9) and one variant of the prototype panoramic night vision goggle (the PNVGII). The panoramic goggle has more than double the horizontal field-of-view of the AVS-9, but reduced image quality. Overall the panoramic goggles compared well to the AVS-9 goggles. However, pilot comment and data are consistent with the assertion that some of the benefits of additional field-of-view with the panoramic goggles were negated by the reduced image quality of the particular variant of the panoramic goggles tested.
Jian, Bo-Lin; Peng, Chao-Chung
2017-06-15
Due to the direct influence of night vision equipment availability on the safety of night-time aerial reconnaissance, maintenance needs to be carried out regularly. Unfortunately, some defects are not easy to observe or are not even detectable by human eyes. As a consequence, this study proposed a novel automatic defect detection system for aviator's night vision imaging systems AN/AVS-6(V)1 and AN/AVS-6(V)2. An auto-focusing process consisting of a sharpness calculation and a gradient-based variable step search method is applied to achieve an automatic detection system for honeycomb defects. This work also developed a test platform for sharpness measurement. It demonstrates that the honeycomb defects can be precisely recognized and the number of the defects can also be determined automatically during the inspection. Most importantly, the proposed approach significantly reduces the time consumption, as well as human assessment error during the night vision goggle inspection procedures.
Square tracking sensor for autonomous helicopter hover stabilization
NASA Astrophysics Data System (ADS)
Oertel, Carl-Henrik
1995-06-01
Sensors for synthetic vision are needed to extend the mission profiles of helicopters. A special task for various applications is the autonomous position hold of a helicopter above a ground fixed or moving target. As a proof of concept for a general synthetic vision solution a restricted machine vision system, which is capable of locating and tracking a special target, was developed by the Institute of Flight Mechanics of Deutsche Forschungsanstalt fur Luft- und Raumfahrt e.V. (i.e., German Aerospace Research Establishment). This sensor, which is specialized to detect and track a square, was integrated in the fly-by-wire helicopter ATTHeS (i.e., Advanced Technology Testing Helicopter System). An existing model following controller for the forward flight condition was adapted for the hover and low speed requirements of the flight vehicle. The special target, a black square with a length of one meter, was mounted on top of a car. Flight tests demonstrated the automatic stabilization of the helicopter above the moving car by synthetic vision.
An atypical presentation of visual conversion disorder.
Foutch, Brian K
2015-01-01
Nonorganic vision loss accounts for up to 5% of patients and presents in two forms, malingering and visual conversion disorder (VCD). It is described a case of VCD in a new mother struggling both with her husband being deployed overseas and the recent death of her father. In addition, she had been evaluated for a concussion secondary to a motor vehicle accident three months prior. An inexpensive series of clinical tests were performed to rule out organic disease and obtained equivocal results. Some tests revealed intact vision in the affected eye while others supported a neurological cause for the vision loss. However, the patient quickly recovered normal visual acuity when encouraged to discuss situations that have been causing emotional stress. This almost immediate recovery of vision confirmed the diagnosis of VCD. This report should make primary eye care professionals more aware of visual conversion disorder and its clinical evaluation. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Jaschinski, Wolfgang; König, Mirjam; Mekontso, Tiofil M; Ohlendorf, Arne; Welscher, Monique
2015-05-01
Two types of progressive addition lenses (PALs) were compared in an office field study: 1. General purpose PALs with continuous clear vision between infinity and near reading distances and 2. Computer vision PALs with a wider zone of clear vision at the monitor and in near vision but no clear distance vision. Twenty-three presbyopic participants wore each type of lens for two weeks in a double-masked four-week quasi-experimental procedure that included an adaptation phase (Weeks 1 and 2) and a test phase (Weeks 3 and 4). Questionnaires on visual and musculoskeletal conditions as well as preferences regarding the type of lenses were administered. After eight more weeks of free use of the spectacles, the preferences were assessed again. The ergonomic conditions were analysed from photographs. Head inclination when looking at the monitor was significantly lower by 2.3 degrees with the computer vision PALs than with the general purpose PALs. Vision at the monitor was judged significantly better with computer PALs, while distance vision was judged better with general purpose PALs; however, the reported advantage of computer vision PALs differed in extent between participants. Accordingly, 61 per cent of the participants preferred the computer vision PALs, when asked without information about lens design. After full information about lens characteristics and additional eight weeks of free spectacle use, 44 per cent preferred the computer vision PALs. On average, computer vision PALs were rated significantly better with respect to vision at the monitor during the experimental part of the study. In the final forced-choice ratings, approximately half of the participants preferred either the computer vision PAL or the general purpose PAL. Individual factors seem to play a role in this preference and in the rated advantage of computer vision PALs. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.
Short-Term Neural Adaptation to Simultaneous Bifocal Images
Radhakrishnan, Aiswaryah; Dorronsoro, Carlos; Sawides, Lucie; Marcos, Susana
2014-01-01
Simultaneous vision is an increasingly used solution for the correction of presbyopia (the age-related loss of ability to focus near images). Simultaneous Vision corrections, normally delivered in the form of contact or intraocular lenses, project on the patient's retina a focused image for near vision superimposed with a degraded image for far vision, or a focused image for far vision superimposed with the defocused image of the near scene. It is expected that patients with these corrections are able to adapt to the complex Simultaneous Vision retinal images, although the mechanisms or the extent to which this happens is not known. We studied the neural adaptation to simultaneous vision by studying changes in the Natural Perceived Focus and in the Perceptual Score of image quality in subjects after exposure to Simultaneous Vision. We show that Natural Perceived Focus shifts after a brief period of adaptation to a Simultaneous Vision blur, similar to adaptation to Pure Defocus. This shift strongly correlates with the magnitude and proportion of defocus in the adapting image. The magnitude of defocus affects perceived quality of Simultaneous Vision images, with 0.5 D defocus scored lowest and beyond 1.5 D scored “sharp”. Adaptation to Simultaneous Vision shifts the Perceptual Score of these images towards higher rankings. Larger improvements occurred when testing simultaneous images with the same magnitude of defocus as the adapting images, indicating that wearing a particular bifocal correction improves the perception of images provided by that correction. PMID:24664087
Berger, Assaf; Findler, Michael; Korach, Tzfanya; Yativ, Oshrat Fono; Gronovich, Yoav; Hassidim, Ayal
2016-04-01
Accumulating clinical and experimental evidence has shown that migraine patients tend to suffer from color vision abnormalities. The aim of this study was to examine whether color vision deficiency is associated with male migraine in a large population of adolescents. The study population included all Israeli male adolescents who underwent medical and cognitive examinations as part of their recruiting process between the years 2007 and 2013. Migraine prevalence among patients with color vision deficiency was compared to that of males without substantial color vision abnormalities. The study population included 305 964 male adolescents at the age of 17 ± 0.6, of whom 7584 (2.5%) had color vision deficiency, as determined by the Farnsworth Panel D-15 color blindness test. Males with color vision deficiency had a 32% increased prevalence of migraine as compared with the control group (odds ratio 1.32, 95% confidence interval 1.18-1.48, P < .001), after adjusting for multiple variables. The authors found an association between color vision deficiency and migraine in male adolescents. The study results lay the basis for further research into male migraine, as well as the visual aspects of migraine. © The Author(s) 2015.
Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N
2014-11-01
Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
Using an Augmented Reality Device as a Distance-based Vision Aid-Promise and Limitations.
Kinateder, Max; Gualtieri, Justin; Dunn, Matt J; Jarosz, Wojciech; Yang, Xing-Dong; Cooper, Emily A
2018-06-06
For people with limited vision, wearable displays hold the potential to digitally enhance visual function. As these display technologies advance, it is important to understand their promise and limitations as vision aids. The aim of this study was to test the potential of a consumer augmented reality (AR) device for improving the functional vision of people with near-complete vision loss. An AR application that translates spatial information into high-contrast visual patterns was developed. Two experiments assessed the efficacy of the application to improve vision: an exploratory study with four visually impaired participants and a main controlled study with participants with simulated vision loss (n = 48). In both studies, performance was tested on a range of visual tasks (identifying the location, pose and gesture of a person, identifying objects, and moving around in an unfamiliar space). Participants' accuracy and confidence were compared on these tasks with and without augmented vision, as well as their subjective responses about ease of mobility. In the main study, the AR application was associated with substantially improved accuracy and confidence in object recognition (all P < .001) and to a lesser degree in gesture recognition (P < .05). There was no significant change in performance on identifying body poses or in subjective assessments of mobility, as compared with a control group. Consumer AR devices may soon be able to support applications that improve the functional vision of users for some tasks. In our study, both artificially impaired participants and participants with near-complete vision loss performed tasks that they could not do without the AR system. Current limitations in system performance and form factor, as well as the risk of overconfidence, will need to be overcome.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
Vision Screening of Ophthalmic Nursing Staff in a Tertiary Eye Care Hospital
Khan, Ruhi A.; Souru, Ches; Vaghese, Sejo; Yasir, Ziaul; Khandekar, Rajiv
2017-01-01
Objectives This study aimed to evaluate ocular healthcare-seeking behaviours and vision screening outcomes of nursing staff at a tertiary eye care hospital. Methods This study was conducted between April and September 2016 among all 500 nurses employed at the King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia. Data were collected on age, gender, use of visual aids, the presence of diabetes, a history of refractive surgery and date of last ocular health check-up. Participants were tested using a handheld Spot™ Vision Screener (Welch Allyn Inc., Skaneateles Falls, New York, USA). Results A total of 150 nurses participated in the study (response rate: 30.0%). The mean age was 41.2 ± 8.9 years old. Distance spectacles, reading spectacles and both types of spectacles were used by 37 (24.7%), 32 (21.3%) and 10 (6.7%) nurses, respectively. A total of 58 nurses (38.7%) failed the vision screening test. Visual defects were detected for the first time in 13 nurses (8.7%). With regards to regular eye checkups, 77 participants (51.3%) reported acceptable ocular healthcare-seeking behaviours; this factor was significantly associated with age and the use of visual aids (P <0.01 each). Conclusion A high proportion of participants failed the vision screening tests and only half displayed good ocular healthcare-seeking behaviours. This is concerning as ophthalmic nurses are likely to face fewer barriers to eye care services than the general population. PMID:28417032
Khan, Ruhi A; Souru, Ches; Vaghese, Sejo; Yasir, Ziaul; Khandekar, Rajiv
2017-02-01
This study aimed to evaluate ocular healthcare-seeking behaviours and vision screening outcomes of nursing staff at a tertiary eye care hospital. This study was conducted between April and September 2016 among all 500 nurses employed at the King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia. Data were collected on age, gender, use of visual aids, the presence of diabetes, a history of refractive surgery and date of last ocular health check-up. Participants were tested using a handheld Spot ™ Vision Screener (Welch Allyn Inc., Skaneateles Falls, New York, USA). A total of 150 nurses participated in the study (response rate: 30.0%). The mean age was 41.2 ± 8.9 years old. Distance spectacles, reading spectacles and both types of spectacles were used by 37 (24.7%), 32 (21.3%) and 10 (6.7%) nurses, respectively. A total of 58 nurses (38.7%) failed the vision screening test. Visual defects were detected for the first time in 13 nurses (8.7%). With regards to regular eye checkups, 77 participants (51.3%) reported acceptable ocular healthcare-seeking behaviours; this factor was significantly associated with age and the use of visual aids ( P <0.01 each). A high proportion of participants failed the vision screening tests and only half displayed good ocular healthcare-seeking behaviours. This is concerning as ophthalmic nurses are likely to face fewer barriers to eye care services than the general population.
Rapid quantification of color vision: the cone contrast test.
Rabin, Jeff; Gooch, John; Ivan, Douglas
2011-02-09
To describe the design, specificity, and sensitivity of the cone contrast test (CCT), a computer-based, cone-specific (L, M, S) contrast sensitivity test for diagnosing type and severity of color vision deficiency (CVD). The CCT presents a randomized series of colored letters visible only to L, M or S cones in decreasing steps of cone contrast to determine L, M, and S letter-recognition thresholds. Sensitivity and specificity were determined by retrospective comparison of CCT scores to anomaloscope and pseudoisochromatic plate (PIP) results in 1446 applicants for pilot training. CVD was detected in 49 (3.4%) of 1446 applicants with hereditary red-green (protan or deutan) CVD detected in 47 (3.5%) of 1359 men and blue-yellow (tritan) in 2 of 1446. In agreement with the anomaloscope, the CCT showed 100% sensitivity for detection and categorization of CVD (40 deutan, 7 protan, 2 tritan). PIP testing showed lower sensitivity (80% detected; 20% missed) due in part to the applicant's prior experience and/or pretest preparation. CCT specificity for confirming normal color vision was 100% for L and M cone tests and 99.8% for S cones. The CCT has sensitivity and specificity comparable to anomaloscope testing and exceeds PIP sensitivity in practiced observers. The CCT provides a rapid (6 minutes), clinically expedient, measure of color vision for quantifying normal color performance, diagnosing type and severity of hereditary deficiency, and detection of acquired sensitivity loss due to ocular, neurologic, and/or systemic disease, as well as injury and physiological stressors, such as altitude and fatigue.
Vision-based algorithms for near-host object detection and multilane sensing
NASA Astrophysics Data System (ADS)
Kenue, Surender K.
1995-01-01
Vision-based sensing can be used for lane sensing, adaptive cruise control, collision warning, and driver performance monitoring functions of intelligent vehicles. Current computer vision algorithms are not robust for handling multiple vehicles in highway scenarios. Several new algorithms are proposed for multi-lane sensing, near-host object detection, vehicle cut-in situations, and specifying regions of interest for object tracking. These algorithms were tested successfully on more than 6000 images taken from real-highway scenes under different daytime lighting conditions.
Hierarchical Modelling Of Mobile, Seeing Robots
NASA Astrophysics Data System (ADS)
Luh, Cheng-Jye; Zeigler, Bernard P.
1990-03-01
This paper describes the implementation of a hierarchical robot simulation which supports the design of robots with vision and mobility. A seeing robot applies a classification expert system for visual identification of laboratory objects. The visual data acquisition algorithm used by the robot vision system has been developed to exploit multiple viewing distances and perspectives. Several different simulations have been run testing the visual logic in a laboratory environment. Much work remains to integrate the vision system with the rest of the robot system.
Hierarchical modelling of mobile, seeing robots
NASA Technical Reports Server (NTRS)
Luh, Cheng-Jye; Zeigler, Bernard P.
1990-01-01
This paper describes the implementation of a hierarchical robot simulation which supports the design of robots with vision and mobility. A seeing robot applies a classification expert system for visual identification of laboratory objects. The visual data acquisition algorithm used by the robot vision system has been developed to exploit multiple viewing distances and perspectives. Several different simulations have been run testing the visual logic in a laboratory environment. Much work remains to integrate the vision system with the rest of the robot system.
Computer graphics testbed to simulate and test vision systems for space applications
NASA Technical Reports Server (NTRS)
Cheatham, John B.
1991-01-01
Research activity has shifted from computer graphics and vision systems to the broader scope of applying concepts of artificial intelligence to robotics. Specifically, the research is directed toward developing Artificial Neural Networks, Expert Systems, and Laser Imaging Techniques for Autonomous Space Robots.
Neuropsychological sequelae of exposure to welding fumes in a group of occupationally exposed men.
Bowler, Rosemarie M; Gysens, Sabine; Diamond, Emily; Booty, Andrew; Hartney, Christopher; Roels, Harry A
2003-10-01
This study compares the neuropsychological function, emotional status, visual function, and illness prevalence of 76 former and current chemical industry welders primarily involved in steel welding, and exposed to welding fumes for an average of 24.9 years with that of 42 unexposed, non-welder controls. Health and occupational history questionnaires were administered, as were the neuropsychological tests included in the World Health Organization Neurobehavioral Core Test Battery, Luria Motor Test, and selected tests from the WAIS-III, and WMS-III. Emotional status tests included the BSI, POMS, BAI, and BDI, and vision tests included the Snellen near visual acuity, Lanthony d-15 color vision, Vistech Contrast Sensitivity, and Schirmer strips. While welders and controls performed similarly on tests of verbal skills, verbal retention, and auditory span, welders performed worse than controls on tests of verbal learning, working memory, cognitive flexibility, visuomotor processing speed, and motor efficiency. Welders had poorer color vision and emotional status, and increased prevalence of illnesses and psychiatric symptoms. The increased symptoms in welders were related to decreased scores on tasks measuring verbal learning, visuomotor abilities, visuospatial abilities, and information processing, and motor efficiency. Within the group of welders, the number of hours welding was negatively related to scores on verbal learning, auditory span, working memory, cognitive flexibility, and motor efficiency.
Vision, Training Hours, and Road Testing Results in Bioptic Drivers
Dougherty, Bradley E.; Flom, Roanne E.; Bullimore, Mark A.; Raasch, Thomas W.
2015-01-01
Purpose Bioptic telescopic spectacles (BTS) can be used by people with central visual acuity that does not meet the state standards to obtain an unrestricted driver’s license. The purpose of this study was to examine the relationships among visual and demographic factors, training hours, and the results of road testing for bioptic drivers. Methods A retrospective study of patients who received an initial daylight bioptic examination at the Ohio State University and subsequently received a bioptic license was conducted. Data were collected on vision including visual acuity, contrast sensitivity, and visual field. Hours of driver training and results of Highway Patrol road testing were extracted from records. Relationships among vision, training hours, and road testing were analyzed. Results Ninety-seven patients who completed a vision examination between 2004 and 2008 and received daylight licensure with BTS were included. Results of the first Highway Patrol road test were available for 74 patients. The median interquartile range (IQR) hours of training prior to road testing was 21±17 hours, (range of 9 to 75 hours). Candidates without previous licensure were younger (p< 0.001) and had more documented training (p< 0.001). Lack of previous licensure and more training were significantly associated with having failed a portion of the Highway Patrol test and points deducted on the road test. Conclusions New bioptic drivers without previous non-bioptic driving experience required more training and performed more poorly on road testing for licensure than those who had previous non-bioptic licensure. No visual factor was predictive of road testing results after adjustment for previous experience. The hours of training received remained predictive of road testing outcome even with adjustment for previous experience. These results suggest that previous experience and trainer assessments should be investigated as potential predictors of road safety in bioptic drivers in future studies. PMID:25946098
Development of a machine vision system for automated structural assembly
NASA Technical Reports Server (NTRS)
Sydow, P. Daniel; Cooper, Eric G.
1992-01-01
Research is being conducted at the LaRC to develop a telerobotic assembly system designed to construct large space truss structures. This research program was initiated within the past several years, and a ground-based test-bed was developed to evaluate and expand the state of the art. Test-bed operations currently use predetermined ('taught') points for truss structural assembly. Total dependence on the use of taught points for joint receptacle capture and strut installation is neither robust nor reliable enough for space operations. Therefore, a machine vision sensor guidance system is being developed to locate and guide the robot to a passive target mounted on the truss joint receptacle. The vision system hardware includes a miniature video camera, passive targets mounted on the joint receptacles, target illumination hardware, and an image processing system. Discrimination of the target from background clutter is accomplished through standard digital processing techniques. Once the target is identified, a pose estimation algorithm is invoked to determine the location, in three-dimensional space, of the target relative to the robots end-effector. Preliminary test results of the vision system in the Automated Structural Assembly Laboratory with a range of lighting and background conditions indicate that it is fully capable of successfully identifying joint receptacle targets throughout the required operational range. Controlled optical bench test results indicate that the system can also provide the pose estimation accuracy to define the target position.
Abu Bakar, Nurul Farhana; Chen, Ai-Hong
2014-02-01
Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. 'Unable to test' was defined as inappropriate response or uncooperative despite best efforts of the screener. The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes ( P < 0.001) but not in Cambridge Crowding Cards, Lang Stereo test II and CVTME. Non verbal or "matching" approaches were found to be more superior in testing visual functions in children with learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities.
Home Lighting Assessment for Clients With Low Vision
Bhorade, Anjali; Gordon, Mae; Hollingsworth, Holly; Engsberg, Jack E.; Baum, M. Carolyn
2013-01-01
OBJECTIVE. The goal was to develop an objective, comprehensive, near-task home lighting assessment for older adults with low vision. METHOD. A home lighting assessment was developed and tested with older adults with low vision. Interrater and test–retest reliability studies were conducted. Clinical utility was assessed by occupational therapists with expertise in low vision rehabilitation. RESULTS. Interrater reliability was high (intraclass correlation coefficient [ICC] = .83–1.0). Test–retest reliability was moderate (ICC = .67). Responses to a Clinical Utility Feedback Form developed for this study indicated that the Home Environment Lighting Assessment (HELA) has strong clinical utility. CONCLUSION. The HELA provides a structured tool to describe the quantitative and qualitative aspects of home lighting environments where near tasks are performed and can be used to plan lighting interventions. The HELA has the potential to affect assessment and intervention practices of rehabilitation professionals in the area of low vision and improve near-task performance of people with low vision. PMID:24195901
Binary pressure-sensitive paint measurements using miniaturised, colour, machine vision cameras
NASA Astrophysics Data System (ADS)
Quinn, Mark Kenneth
2018-05-01
Recent advances in machine vision technology and capability have led to machine vision cameras becoming applicable for scientific imaging. This study aims to demonstrate the applicability of machine vision colour cameras for the measurement of dual-component pressure-sensitive paint (PSP). The presence of a second luminophore component in the PSP mixture significantly reduces its inherent temperature sensitivity, increasing its applicability at low speeds. All of the devices tested are smaller than the cooled CCD cameras traditionally used and most are of significantly lower cost, thereby increasing the accessibility of such technology and techniques. Comparisons between three machine vision cameras, a three CCD camera, and a commercially available specialist PSP camera are made on a range of parameters, and a detailed PSP calibration is conducted in a static calibration chamber. The findings demonstrate that colour machine vision cameras can be used for quantitative, dual-component, pressure measurements. These results give rise to the possibility of performing on-board dual-component PSP measurements in wind tunnels or on real flight/road vehicles.
Neuromorphic vision sensors and preprocessors in system applications
NASA Astrophysics Data System (ADS)
Kramer, Joerg; Indiveri, Giacomo
1998-09-01
A partial review of neuromorphic vision sensors that are suitable for use in autonomous systems is presented. Interfaces are being developed to multiplex the high- dimensional output signals of arrays of such sensors and to communicate them in standard formats to off-chip devices for higher-level processing, actuation, storage and display. Alternatively, on-chip processing stages may be implemented to extract sparse image parameters, thereby obviating the need for multiplexing. Autonomous robots are used to test neuromorphic vision chips in real-world environments and to explore the possibilities of data fusion from different sensing modalities. Examples of autonomous mobile systems that use neuromorphic vision chips for line tracking and optical flow matching are described.
Teaching with Vision: Culturally Responsive Teaching in Standards-Based Classrooms
ERIC Educational Resources Information Center
Sleeter, Christine E., Ed.; Cornbleth, Catherine, Ed.
2011-01-01
In "Teaching with Vision," two respected scholars in teaching for social justice have gathered teachers from across the country to describe rich examples of extraordinary practice. This collection showcases the professional experience and wisdom of classroom teachers who have been navigating standards- and test-driven teaching environments in…
Professional Vision: Elementary School Principals' Perceptions of Mathematics Instruction
ERIC Educational Resources Information Center
Schoen, Robert C.
2010-01-01
This study explored 78 elementary school principals' perceptions of classroom mathematics instruction in an effort to build understanding of the professional vision (Goodwin, 1994) of elementary school principals as it relates to mathematics instruction. This study also tested the theory of Leadership Content Knowledge (Stein & Nelson, 2003)…
DOT National Transportation Integrated Search
2015-03-01
This report concerns two issues: 1) whether color vision is necessary for locomotive crews who work on railroads where the signal system is either completely redundant with regard to signal color and signal orientation or the signal system only uses ...
Diagnosis of Normal and Abnormal Color Vision with Cone-Specific VEPs.
Rabin, Jeff C; Kryder, Andrew C; Lam, Dan
2016-05-01
Normal color vision depends on normal long wavelength (L), middle wavelength (M), and short wavelength sensitive (S) cones. Hereditary "red-green" color vision deficiency (CVD) is due to a shift in peak sensitivity or lack of L or M cones. Hereditary S cone CVD is rare but can be acquired as an early sign of disease. Current tests detect CVD but few diagnose type or severity, critical for linking performance to real-world demands. The anomaloscope and newer subjective tests quantify CVD but are not applicable to infants or cognitively impaired patients. Our purpose was to develop an objective test of CVD with sensitivity and specificity comparable to current tests. A calibrated visual-evoked potential (VEP) display and Food and Drug Administration-approved system was used to record L, M, and S cone-specific pattern-onset VEPs from 18 color vision normals (CVNs) and 13 hereditary CVDs. VEP amplitudes and latencies were compared between groups to establish VEP sensitivity and specificity. Cone VEPs show 100% sensitivity for diagnosis of CVD and 94% specificity for confirming CVN. L cone (protan) CVDs showed a significant increase in L cone latency (53.1 msec, P < 0.003) and decreased amplitude (10.8 uV, P < 0.0000005) but normal M and S cone VEPs ( P > 0.31). M cone (deutan) CVDs showed a significant increase in M cone latency (31.0 msec, P < 0.000004) and decreased amplitude (8.4 uV, P < 0.006) but normal L and S cone VEPs ( P > 0.29). Cone-specific VEPs offer a rapid, objective test to diagnose hereditary CVD and show potential for detecting acquired CVD in various diseases. This paper describes the efficacy of cone-specific color VEPs for quantification of normal and abnormal color vision. The rapid, objective nature of this approach makes it suitable for detecting color sensitivity loss in infants and the cognitively impaired.
Bhattacharya, Sudin; Zhang, Qiang; Carmichael, Paul L.; Boekelheide, Kim; Andersen, Melvin E.
2011-01-01
The approaches to quantitatively assessing the health risks of chemical exposure have not changed appreciably in the past 50 to 80 years, the focus remaining on high-dose studies that measure adverse outcomes in homogeneous animal populations. This expensive, low-throughput approach relies on conservative extrapolations to relate animal studies to much lower-dose human exposures and is of questionable relevance to predicting risks to humans at their typical low exposures. It makes little use of a mechanistic understanding of the mode of action by which chemicals perturb biological processes in human cells and tissues. An alternative vision, proposed by the U.S. National Research Council (NRC) report Toxicity Testing in the 21st Century: A Vision and a Strategy, called for moving away from traditional high-dose animal studies to an approach based on perturbation of cellular responses using well-designed in vitro assays. Central to this vision are (a) “toxicity pathways” (the innate cellular pathways that may be perturbed by chemicals) and (b) the determination of chemical concentration ranges where those perturbations are likely to be excessive, thereby leading to adverse health effects if present for a prolonged duration in an intact organism. In this paper we briefly review the original NRC report and responses to that report over the past 3 years, and discuss how the change in testing might be achieved in the U.S. and in the European Union (EU). EU initiatives in developing alternatives to animal testing of cosmetic ingredients have run very much in parallel with the NRC report. Moving from current practice to the NRC vision would require using prototype toxicity pathways to develop case studies showing the new vision in action. In this vein, we also discuss how the proposed strategy for toxicity testing might be applied to the toxicity pathways associated with DNA damage and repair. PMID:21701582
2007-07-01
SAS System Analysis and Studies Panel • SCI Systems Concepts and Integration Panel • SET Sensors and Electronics Technology Panel These...Daylight Readability 4-2 4.1.4 Night-Time Readability 4-2 4.1.5 NVIS Radiance 4-2 4.1.6 Human Factors Analysis 4-3 4.1.7 Flight Tests 4-3 4.1.7.1...position is shadowing. Moonlight creates shadows during night-time just as sunlight does during the day. Understanding what cannot be seen in night-time
Are dogs red-green colour blind?
Siniscalchi, Marcello; d'Ingeo, Serenella; Fornelli, Serena; Quaranta, Angelo
2017-11-01
Neurobiological and molecular studies suggest a dichromatic colour vision in canine species, which appears to be similar to that of human red-green colour blindness. Here, we show that dogs exhibit a behavioural response similar to that of red-green blind human subjects when tested with a modified version of a test commonly used for the diagnosis of human deuteranopia (i.e. the Ishihara's test). Besides contributing to increasing the knowledge about the perceptual ability of dogs, the present work describes for the first time, to our knowledge, a method that can be used to assess colour vision in the animal kingdom.
Focal damage to macaque photoreceptors produces persistent visual loss
Strazzeri, Jennifer M.; Hunter, Jennifer J.; Masella, Benjamin D.; Yin, Lu; Fischer, William S.; DiLoreto, David A.; Libby, Richard T.; Williams, David R.; Merigan, William H.
2014-01-01
Insertion of light-gated channels into inner retina neurons restores neural light responses, light evoked potentials, visual optomotor responses and visually-guided maze behavior in mice blinded by retinal degeneration. This method of vision restoration bypasses damaged outer retina, providing stimulation directly to retinal ganglion cells in inner retina. The approach is similar to that of electronic visual protheses, but may offer some advantages, such as avoidance of complex surgery and direct targeting of many thousands of neurons. However, the promise of this technique for restoring human vision remains uncertain because rodent animal models, in which it has been largely developed, are not ideal for evaluating visual perception. On the other hand, psychophysical vision studies in macaque can be used to evaluate different approaches to vision restoration in humans. Furthermore, it has not been possible to test vision restoration in macaques, the optimal model for human-like vision, because there has been no macaque model of outer retina degeneration. In this study, we describe development of a macaque model of photoreceptor degeneration that can in future studies be used to test restoration of perception by visual prostheses. Our results show that perceptual deficits caused by focal light damage are restricted to locations at which photoreceptors are damaged, that optical coherence tomography (OCT) can be used to track such lesions, and that adaptive optics retinal imaging, which we recently used for in vivo recording of ganglion cell function, can be used in future studies to examine these lesions. PMID:24316158
Adjustable typography: an approach to enhancing low vision text accessibility.
Arditi, Aries
2004-04-15
Millions of people have low vision, a disability condition caused by uncorrectable or partially correctable disorders of the eye. The primary goal of low vision rehabilitation is increasing access to printed material. This paper describes how adjustable typography, a computer graphic approach to enhancing text accessibility, can play a role in this process, by allowing visually-impaired users to customize fonts to maximize legibility according to their own visual needs. Prototype software and initial testing of the concept is described. The results show that visually-impaired users tend to produce a variety of very distinct fonts, and that the adjustment process results in greatly enhanced legibility. But this initial testing has not yet demonstrated increases in legibility over and above the legibility of highly legible standard fonts such as Times New Roman.
Harley, H E; Roitblat, H L; Nachtigall, P E
1996-04-01
A dolphin performed a 3-alternative matching-to-sample task in different modality conditions (visual/echoic, both vision and echolocation: visual, vision only; echoic, echolocation only). In Experiment 1, training occurred in the dual-modality (visual/echoic) condition. Choice accuracy in tests of all conditions was above chance without further training. In Experiment 2, unfamiliar objects with complementary similarity relations in vision and echolocation were presented in single-modality conditions until accuracy was about 70%. When tested in the visual/echoic condition, accuracy immediately rose (95%), suggesting integration across modalities. In Experiment 3, conditions varied between presentation of sample and alternatives. The dolphin successfully matched familiar objects in the cross-modal conditions. These data suggest that the dolphin has an object-based representational system.
Chang, Li-Chun; Guo, Jong-Long; Liao, Li-Ling; Peng, Hsiu-Ying; Hsieh, Pei-Lin
2017-09-01
Myopia, the most common refractive error, is the most common cause of avoidable visual impairment among children and has reached epidemic proportions among children and young adults in urban areas of East and Southeast Asia that contain populations of Chinese ancestry. Moreover, vision health is an important theme of the health-promoting school program issued by the Ministry of Education in Taiwan. The aim of this study is to assess the impact of pre- and post-intervention proposed by the health-promoting school (HPS) model. The objectives are to understand whether the HPS model influenced the vision screening results and the attitude, knowledge level, and vision care behavior of the students involved. A prospective cohort study design was used to evaluate a vision health program. Four elementary schools, local education authorities, and one university in northern Taiwan established a coalition partnership to design a six-month program to combat myopia among students. The target population was 6668 school children from local elementary schools. For the purpose of this study, the outcome of visual acuity testing (in logMAR) was analyzed with a sampling of 373 school children (aged 11-12 years old) who were chosen from high prevalence of poor vision classes. After the HPS program, the attitudes, behaviors, and knowledge levels of the school children regarding vision health were significantly improved. The pre-intervention mean logMAR of all participating students ( N = 373) was -.10, which increased to -.19 after the intervention. Analysis using the Wilcoxon signed-rank test showed that the logMAR value was significantly improved after the intervention ( t = 2.13, p < 0.05). Our findings highlight the relevance and effectiveness of the coalition's efforts, which reinforces the usefulness of co-operatively implementing the HPS program.
Freeman, William R.; Van Natta, Mark L.; Jabs, Douglas; Sample, Pamela A.; Sadun, Alfredo A.; Thorne, Jennifer; Shah, Kayur H.; Holland, Gary N.
2008-01-01
Purpose To evaluate the prevalence and risk factors for vision loss in patients with clinical or immunologic AIDS without infectious retinitis. Design A prospective multicentered cohort study of patients with AIDS. Methods 1,351 patients (2,671 eyes) at 19 clinical trials centers diagnosed with AIDS but without major ocular complications of HIV. Standardized measurements of visual acuity, automated perimetry, and contrast sensitivity were analyzed and correlated with measurements of patients’ health and medical data relating to HIV infection. We evaluated correlations between vision function testing and HIV-related risk factors and medical testing. Results There were significant (p<0.05) associations between measures of decreasing vision function and indices of increasing disease severity including Karnofsky score and hemoglobin. A significant relationship was seen between low contrast sensitivity and decreasing levels of CD4+ T-cell count. Three percent of eyes had a visual acuity worse than 20/40 Snellen equivalents, which was significantly associated with a history of opportunistic infections and low Karnofsky score. When compared to external groups with normal vision, 39% of eyes had abnormal mean deviation on automated perimetry, 33% had abnormal pattern standard deviation, and 12% of eyes had low contrast sensitivity. Conclusions This study confirms that visual dysfunction is common in patients with AIDS but without retinitis. The most prevalent visual dysfunction is loss of visual field; nearly 40% of patients have some abnormal visual field. There is an association between general disease severity and less access to care and vision loss. The pathophysiology of this vision loss is unknown but is consistent with retinovascular disease or optic nerve disease. PMID:18191094
Bhati, Hitesh; Manjusha, R
2015-01-01
Senile cataract is the leading cause of blindness according to the World Health Report, 1998. Till date no accepted medical treatment is available for cataract. In Ayurveda visual disturbances are described in the context of Timira, Kacha and Linganasha. Timira is an early stage characterized by blurring of vision and Linganasha is end stage where complete loss of vision occurs. Ancient scholars have advocated different Anjana application and oral medications in the Timira and Kacha stage. To study the efficacy of test drugs Triphaladi Ghana Vati and Elaneer Kuzhambu Anjana in immature cataract. In this trial patients having Senile Immature Cataract were randomized with equal probability to one of the two treatment Groups A and B (n = 20 each). In Group A Triphaladi Ghana Vati 500 mg internally for 3 months and in Group B Triphaladi Ghana Vati 500 mg internally and Elaneer Kuzhambu Anjana for local application were given. Assessment was done on the basis of blurring of vision, visualization of nonexisting things, difficulty in bright light and dim light or night vision, distant visual acuity, pinhole vision, best corrected visual acuity and cataract grading on slit lamp. Both groups showed statistically significant changes in blurring of vision, difficulty in glare, daytime and bright light, distant visual activity, pinhole vision, and best-corrected visual acuity. Group B also showed significant changes in difficulty in night time, visualization of nonexisting things and in nuclear cataract. The study establishes that test drugs can reduce and control the progress of immature cataract, and combined therapy was found more effective. Chakshushya Rasayana, early diagnosis and proper management on Doshic lines can prevent arrest or delay senile cataract.
Bhati, Hitesh; Manjusha, R.
2015-01-01
Introduction: Senile cataract is the leading cause of blindness according to the World Health Report, 1998. Till date no accepted medical treatment is available for cataract. In Ayurveda visual disturbances are described in the context of Timira, Kacha and Linganasha. Timira is an early stage characterized by blurring of vision and Linganasha is end stage where complete loss of vision occurs. Ancient scholars have advocated different Anjana application and oral medications in the Timira and Kacha stage. Aim: To study the efficacy of test drugs Triphaladi Ghana Vati and Elaneer Kuzhambu Anjana in immature cataract. Materials and Methods: In this trial patients having Senile Immature Cataract were randomized with equal probability to one of the two treatment Groups A and B (n = 20 each). In Group A Triphaladi Ghana Vati 500 mg internally for 3 months and in Group B Triphaladi Ghana Vati 500 mg internally and Elaneer Kuzhambu Anjana for local application were given. Assessment was done on the basis of blurring of vision, visualization of nonexisting things, difficulty in bright light and dim light or night vision, distant visual acuity, pinhole vision, best corrected visual acuity and cataract grading on slit lamp. Results: Both groups showed statistically significant changes in blurring of vision, difficulty in glare, daytime and bright light, distant visual activity, pinhole vision, and best-corrected visual acuity. Group B also showed significant changes in difficulty in night time, visualization of nonexisting things and in nuclear cataract. Conclusion: The study establishes that test drugs can reduce and control the progress of immature cataract, and combined therapy was found more effective. Chakshushya Rasayana, early diagnosis and proper management on Doshic lines can prevent arrest or delay senile cataract. PMID:27313415
Olderbak, Sally; Hildebrandt, Andrea; Wilhelm, Oliver
2015-01-01
The shared decline in cognitive abilities, sensory functions (e.g., vision and hearing), and physical health with increasing age is well documented with some research attributing this shared age-related decline to a single common cause (e.g., aging brain). We evaluate the extent to which the common cause hypothesis predicts associations between vision and physical health with social cognition abilities specifically face perception and face memory. Based on a sample of 443 adults (17–88 years old), we test a series of structural equation models, including Multiple Indicator Multiple Cause (MIMIC) models, and estimate the extent to which vision and self-reported physical health are related to face perception and face memory through a common factor, before and after controlling for their fluid cognitive component and the linear effects of age. Results suggest significant shared variance amongst these constructs, with a common factor explaining some, but not all, of the shared age-related variance. Also, we found that the relations of face perception, but not face memory, with vision and physical health could be completely explained by fluid cognition. Overall, results suggest that a single common cause explains most, but not all age-related shared variance with domain specific aging mechanisms evident. PMID:26321998
Delhey, Kaspar; Hall, Michelle; Kingma, Sjouke A; Peters, Anne
2013-01-07
Colour signals are expected to match visual sensitivities of intended receivers. In birds, evolutionary shifts from violet-sensitive (V-type) to ultraviolet-sensitive (U-type) vision have been linked to increased prevalence of colours rich in shortwave reflectance (ultraviolet/blue), presumably due to better perception of such colours by U-type vision. Here we provide the first test of this widespread idea using fairy-wrens and allies (Family Maluridae) as a model, a family where shifts in visual sensitivities from V- to U-type eyes are associated with male nuptial plumage rich in ultraviolet/blue colours. Using psychophysical visual models, we compared the performance of both types of visual systems at two tasks: (i) detecting contrast between male plumage colours and natural backgrounds, and (ii) perceiving intraspecific chromatic variation in male plumage. While U-type outperforms V-type vision at both tasks, the crucial test here is whether U-type vision performs better at detecting and discriminating ultraviolet/blue colours when compared with other colours. This was true for detecting contrast between plumage colours and natural backgrounds (i), but not for discriminating intraspecific variability (ii). Our data indicate that selection to maximize conspicuousness to conspecifics may have led to the correlation between ultraviolet/blue colours and U-type vision in this clade of birds.
Tan, N C; Yip, W F; Kallakuri, S; Sankari, U; Koh, Y L E
2017-06-02
Patients with type 2 diabetes mellitus (T2DM) may develop color vision impairment. This study aimed to determine the prevalence and factors associated with impaired color vision in patients with T2DM but without diabetic retinopathy. Enrolment criteria included multi-ethnic Asian participants, age 21 to 80 years, with known T2DM for a minimum of 2 years. Their diagnoses were affirmed from oral glucose tolerance test results and they were screened for impaired color vision using the Farnsworth D-15 instrument. Demographic characteristics were described and clinical data for the preceding 2 years were analyzed using logistic regression. Twenty-two percent of 849 eligible participants had impaired color vision with higher involvement of the right eye. Impaired blue-yellow color-vision(Tritanomaly) was the commonest impaired color vision. Participants with impaired color vision were significantly associated with age and lower education; longer duration of T2DM (median 6 years vs 4 years); higher HbA1c level and HDL-Cholesterol in 2nd year; lower mean total cholesterol, mean LDL-Cholesterol and mean triglyceride in 2nd year. They also have poorer vision beyond 6/12 in the affected eye. Logistic regression showed that impaired color vision was associated with older patients (OR=1.04), increased duration of T2DM (OR=1.07); prescription of Tolbutamide (OR=3.79) and lower mean systolic blood pressure (OR=0.98). Almost one in four participants with T2DM had impaired color vision, largely with tritanomaly. Color vision screening may be considered for participants who develop T2DM for 6 years or longer, but this requires further cost-effectiveness evaluation.
Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha
To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
16 CFR 1203.13 - Test schedule.
Code of Federal Regulations, 2010 CFR
2010-01-01
... environments, respectively) shall be tested in accordance with the dynamic retention system strength test at... Peripheral vision § 1203.15 Positional stability § 1203.16 Retention system strength § 1203.17 Impact tests...
The use of a newspaper insertion to promote DIY testing of vision in India.
Murthy, G V; Gupta, S K; Dada, V K; Pant, T D; Savita, C; Sanga, L; Neena, J
2001-08-01
The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated. A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness. 603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant. Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India.
The use of a newspaper insertion to promote DIY testing of vision in India
Murthy, G; Gupta, S. K.; Dada, V. K.; Pant, T. D.; Savita, C.; Sanga, L.; Neena, J.
2001-01-01
BACKGROUND—The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated. METHODS—A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness. RESULTS—603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant. CONCLUSIONS—Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India. PMID:11466254
Vision Problems and Reduced Reading Outcomes in Queensland Schoolchildren.
Hopkins, Shelley; Sampson, Geoff P; Hendicott, Peter L; Wood, Joanne M
2017-03-01
To assess the relationship between vision and reading outcomes in Indigenous and non-Indigenous schoolchildren to determine whether vision problems are associated with lower reading outcomes in these populations. Vision testing and reading assessments were performed on 508 Indigenous and non-Indigenous schoolchildren in Queensland, Australia divided into two age groups: Grades 1 and 2 (6-7 years of age) and Grades 6 and 7 (12-13 years of age). Vision parameters measured included cycloplegic refraction, near point of convergence, heterophoria, fusional vergence range, rapid automatized naming, and visual motor integration. The following vision conditions were then classified based on the vision findings: uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration. Reading accuracy and reading comprehension were measured with the Neale reading test. The effect of uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration on reading accuracy and reading comprehension were investigated with ANCOVAs. The ANCOVAs explained a significant proportion of variance in both reading accuracy and reading comprehension scores in both age groups, with 40% of the variation in reading accuracy and 33% of the variation in reading comprehension explained in the younger age group, and 27% and 10% of the variation in reading accuracy and reading comprehension, respectively, in the older age group. The vision parameters of visual motor integration and rapid automatized naming were significant predictors in all ANCOVAs (P < .01). The direction of the relationship was such that reduced reading results were explained by reduced visual motor integration and rapid automatized naming results. Both reduced rapid automatized naming and visual motor integration were associated with poorer reading outcomes in Indigenous and non-Indigenous children. This is an important finding given the recent emphasis placed on Indigenous children's reading skills and the fact that reduced rapid automatized naming and visual motor integration skills are more common in this group.
Shoji, T; Sakurai, Y; Sato, H; Chihara, E; Takeuchi, M
2011-07-01
To investigate associations between fasting plasma glucose level and the prevalence of acquired colour vision impairment in type 2 diabetes patients without diabetic retinopathy. Participants in this cross-sectional study of male officials aged 20-60 yr in the Japanese Self Defence Force, underwent colour vision testing, ophthalmic examination, a standardized interview and examination of venous blood samples. Ishihara plates, a Lanthony 15-hue desaturated panel and Standard Pseudoisochromatic Plates Part 2 were used to examine colour vision. The Farnsworth-Munsell 100-hue test was performed to define acquired colour vision impairment. Cardiovascular disease risk factors were determined from serum blood samples, physical records and an interview. We performed logistic regression analysis adjusted for age, diagnosed hypertension, dyslipidaemia, cataract, glaucoma, being overweight, smoking status and alcohol intake. Crude and adjusted odds ratios were calculated for three glucose levels, which included normal fasting glucose, impaired fasting glucose and diabetes. Out of a total of 1042 men enrolled, 872 were eligible for the study, and 31 were diagnosed with acquired colour vision impairment. As compared with the subjects with normal fasting glucose (< 5.6 mmol/l), the crude odds ratio for acquired colour vision impairment was 0.93 (95% CI 0.32-2.74) for the subjects with impaired fasting glucose (5.6-6.9 mmol/l) and 8.07 (95% CI 2.48-26.22) for the patients with type 2 diabetes. The multiple-adjusted odds ratios were 0.77 (95% CI 0.25-2.34) for the subjects with impaired fasting glucose and 5.89 (95% CI 1.55-22.40) for the patients with type 2 diabetes. Our findings suggest that there is a dramatically increased prevalence of acquired colour vision impairment in type 2 diabetes patients without diabetic retinopathy which might be attributable to another pathogenesis associated with diabetic retinopathy. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.
FLORA™: Phase I development of a functional vision assessment for prosthetic vision users
Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy
2014-01-01
Background Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population in order to evaluate the impact of new vision restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional vision ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. Methods The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional vision tasks for observation of performance, and a case narrative summary. Results were analyzed to determine whether the interview questions and functional vision tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, twenty-six subjects were assessed with the FLORA. Seven different evaluators administered the assessment. Results All 14 interview questions were asked. All 35 functional vision tasks were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options -- impossible (33%), difficult (23%), moderate (24%) and easy (19%) -- were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with vision only occurring 75% on average with the System ON, and 29% with the System OFF. Conclusion The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as a functional vision and well-being assessment tool. PMID:25675964
Gait in Parkinson's disease: A visuo-cognitive challenge.
Stuart, Samuel; Lord, Sue; Hill, Elizabeth; Rochester, Lynn
2016-03-01
Vision and cognition have both been related to gait impairment in Parkinson's disease (PD) through separate strands of research. The cumulative and interactive effect of both (which we term visuo-cognition) has not been previously investigated and little is known about the influence of cognition on vision with respect to gait. Understanding the role of vision, cognition and visuo-cognition in gait in PD is critical for data interpretation and to infer and test underlying mechanisms. The purpose of this comprehensive narrative review was to examine the interdependent and interactive role of cognition and vision in gait in PD and older adults. Evidence from a broad range of research disciplines was reviewed and summarised. A key finding was that attention appears to play a pivotal role in mediating gait, cognition and vision, and should be considered emphatically in future research in this field. Copyright © 2016 Elsevier Ltd. All rights reserved.
Skrzat, Janusz; Sioma, Andrzej; Kozerska, Magdalena
2013-01-01
In this paper we present potential usage of the 3D vision system for registering features of the macerated cranial bones. Applied 3D vision system collects height profiles of the object surface and from that data builds a three-dimensional image of the surface. This method appeared to be accurate enough to capture anatomical details of the macerated bones. With the aid of the 3D vision system we generated images of the surface of the human calvaria which was used for testing the system. Performed reconstruction visualized the imprints of the dural vascular system, cranial sutures, and the three-layer structure of the cranial bones observed in the cross-section. We figure out that the 3D vision system may deliver data which can enhance estimation of sex from the osteological material.
A note on image degradation, disability glare, and binocular vision
NASA Astrophysics Data System (ADS)
Rajaram, Vandana; Lakshminarayanan, Vasudevan
2013-08-01
Disability glare due to scattering of light causes a reduction in visual performance due to a luminous veil over the scene. This causes problem such as contrast detection. In this note, we report a study of the effect of this veiling luminance on human stereoscopic vision. We measured the effect of glare on the horopter measured using the apparent fronto-parallel plane (AFPP) criterion. The empirical longitudinal horopter measured using the AFPP criterion was analyzed using the so-called analytic plot. The analytic plot parameters were used for quantitative measurement of binocular vision. Image degradation plays a major effect on binocular vision as measured by the horopter. Under the conditions tested, it appears that if vision is sufficiently degraded then the addition of disability glare does not seem to significantly cause any further compromise in depth perception as measured by the horopter.
Color Vision and Performance on Color-Coded Cockpit Displays.
Gaska, James P; Wright, Steven T; Winterbottom, Marc D; Hadley, Steven C
Although there are numerous studies that demonstrate that color vision deficient (CVD) individuals perform less well than color vision normal (CVN) individuals in tasks that require discrimination or identification of colored stimuli, there remains a need to quantify the relationship between the type and severity of CVD and performance on operationally relevant tasks. Participants were classified as CVN (N = 45) or CVD (N = 49) using the Rabin cone contrast test, which is the standard color vision screening test used by the United States Air Force. In the color condition, test images that were representative of the size, shape, and color of symbols and lines used on fifth-generation fighter aircraft displays were used to measure operational performance. In the achromatic condition, all symbols and lines had the same chromaticity but differed in luminance. Subjects were asked to locate and discriminate between friend vs. foe symbols (red vs. green, or brighter vs. dimmer) while speed and accuracy were recorded. Increasing color deficiency was associated with decreasing speed and accuracy for the color condition (R 2 > 0.2), but not for the achromatic condition. Mean differences between CVN and CVD individuals showed the same pattern. Although lower CCT scores are clearly associated with lower performance in color related tasks, the magnitude of the performance loss was relatively small and there were multiple examples of high-performing CVD individuals who had higher operational scores than low-performing CVN individuals. Gaska JP, Wright ST, Winterbottom MD, Hadley SC. Color vision and performance on color-coded cockpit displays. Aerosp Med Hum Perform. 2016; 87(11):921-927.
NASA Astrophysics Data System (ADS)
Balbin, Jessie R.; Pinugu, Jasmine Nadja J.; Bautista, Joshua Ian C.; Nebres, Pauline D.; Rey Hipolito, Cipriano M.; Santella, Jose Anthony A.
2017-06-01
Visual processing skill is used to gather visual information from environment however, there are cases that Visual Processing Disorder (VPD) occurs. The so called visual figure-ground discrimination is a type of VPD where color is one of the factors that contributes on this type. In line with this, color plays a vital role in everyday living, but individuals that have limited and inaccurate color perception suffers from Color Vision Deficiency (CVD) and still not aware on their case. To resolve this case, this study focuses on the design of KULAY, a Head-Mounted Display (HMD) device that can assess whether a user has a CVD or not thru the standard Hardy-Rand-Rittler (HRR) test. This test uses pattern recognition in order to evaluate the user. In addition, color vision deficiency simulation and color correction thru color transformation is also a concern of this research. This will enable people with normal color vision to know how color vision deficient perceives and vice-versa. For the accuracy of the simulated HRR assessment, its results were validated thru an actual assessment done by a doctor. Moreover, for the preciseness of color transformation, Structural Similarity Index Method (SSIM) was used to compare the simulated CVD images and the color corrected images to other reference sources. The output of the simulated HRR assessment and color transformation shows very promising results indicating effectiveness and efficiency of the study. Thus, due to its form factor and portability, this device is beneficial in the field of medicine and technology.
... testing when performed at a doctor's office. Corneal light reflex testing This simple test can be performed ... focuses on a penlight, the position of the light reflection from the front surface (cornea) of the ...
VISION AND COLLEGE READING - A REVIEW OF THE LITERATURE AND REPORT OF A SURVEY.
ERIC Educational Resources Information Center
MAXWELL, MARTHA J.
THE AMERICAN OPTICAL (AO) COMPANY'S SIGHT SCREENER, A PORTABLE BINOCULAR INSTRUMENT DESIGNED FOR MASS VISION TESTING, WAS EVALUATED AT THE UNIVERSITY OF MARYLAND READING AND STUDY SKILLS LABORATORY TO DETERMINE ITS CAPACITY TO IDENTIFY STUDENTS NEEDING PROFESSIONAL EYE EXAMINATIONS PRIOR TO READING INSTRUCTION. DATA FROM 106 PROBATIONARY FRESHMEN,…
VISIONS for Greater Employment Opportunities. Final Report.
ERIC Educational Resources Information Center
Orangeburg-Calhoun Technical Coll., Orangeburg, SC.
The VISIONS project, a workplace literacy program held in two manufacturing plants and a regional medical center, was conducted during an 18-month period from July 1, 1993 to December 31, 1994. During the project, staff were hired and trained, task analyses and orientation sessions were held, and tests and curricula were developed. Employees were…
Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja
2016-03-01
Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.
Computer graphics testbed to simulate and test vision systems for space applications
NASA Technical Reports Server (NTRS)
Cheatham, John B.; Wu, Chris K.; Lin, Y. H.
1991-01-01
A system was developed for displaying computer graphics images of space objects and the use of the system was demonstrated as a testbed for evaluating vision systems for space applications. In order to evaluate vision systems, it is desirable to be able to control all factors involved in creating the images used for processing by the vision system. Considerable time and expense is involved in building accurate physical models of space objects. Also, precise location of the model relative to the viewer and accurate location of the light source require additional effort. As part of this project, graphics models of space objects such as the Solarmax satellite are created that the user can control the light direction and the relative position of the object and the viewer. The work is also aimed at providing control of hue, shading, noise and shadows for use in demonstrating and testing imaging processing techniques. The simulated camera data can provide XYZ coordinates, pitch, yaw, and roll for the models. A physical model is also being used to provide comparison of camera images with the graphics images.
Ultraviolet vision may be widespread in bats
Gorresen, P. Marcos; Cryan, Paul; Dalton, David C.; Wolf, Sandy; Bonaccorso, Frank
2015-01-01
Insectivorous bats are well known for their abilities to find and pursue flying insect prey at close range using echolocation, but they also rely heavily on vision. For example, at night bats use vision to orient across landscapes, avoid large obstacles, and locate roosts. Although lacking sharp visual acuity, the eyes of bats evolved to function at very low levels of illumination. Recent evidence based on genetics, immunohistochemistry, and laboratory behavioral trials indicated that many bats can see ultraviolet light (UV), at least at illumination levels similar to or brighter than those before twilight. Despite this growing evidence for potentially widespread UV vision in bats, the prevalence of UV vision among bats remains unknown and has not been studied outside of the laboratory. We used a Y-maze to test whether wild-caught bats could see reflected UV light and whether such UV vision functions at the dim lighting conditions typically experienced by night-flying bats. Seven insectivorous species of bats, representing five genera and three families, showed a statistically significant ‘escape-toward-the-light’ behavior when placed in the Y-maze. Our results provide compelling evidence of widespread dim-light UV vision in bats.
Gadkari, Salil; Kamdar, Rushita; Kulkarni, Sucheta; Deshpande, Madan; Taras, Sudhir
2015-05-01
To demonstrate improvement in the vision of babies after successful vitrectomy for stage 4b retinopathy of prematurity (ROP) over an extended period of time. This was an observational prospective case series. Eight babies who had undergone successful vitrectomy in either their only seeing eye (or both eyes) with stage 4b ROP were followed up post-operatively for a period of 80 weeks or more. Vision with Teller acuity chart, refraction, binocular indirect ophthalmoscopy, and documentation with RetCam was done at each visit. Vision of the (only/better) seeing operated eye with corrective glasses was graded for the purpose of statistical evaluation. Paired t test was performed to compare the vision prior to 30 weeks and at or after 80 weeks. Statistically significant improvement in vision was noted at or after 80 weeks as compared to the vision recorded before 30 weeks (p = 0.0062). Unlike in adult intraocular surgeries where stable visual acuity is reached well before 30 weeks, continuing improvement at 80 weeks and beyond is noted. Gradual restoration of the retinal architecture and plasticity of the infant's developing brain are thought to be responsible.
Color vision impairment with low-level methylmercury exposure of an Amazonian population - Brazil.
Feitosa-Santana, Claudia; Souza, Givago da Silva; Sirius, Esaú Ventura Pupo; Rodrigues, Anderson Raiol; Cortes, Maria Izabel Tentes; Silveira, Luiz Carlos de Lima; Ventura, Dora Fix
2018-05-01
Land exploitation that follows deforestation and mining can result in soil erosion and the release of mercury to the waters of rivers in the Amazon Basin. Inorganic mercury is methylated by bacteria that are present in the environment and it serves as a source of human contamination through fish consumption in the form of methylmercury. Long-term exposure to low-level methylmercury in the riverside populations can lead to nervous system alterations, some of which are visual impairments such as loss of luminance contrast sensitivity, restricted visual fields and color vision defects. The present study sought to examine color vision in a group of adults living in the central Brazilian Amazon who were exposed to low-levels of methylmercury. Total Hg concentrations were measured from hair collected at the time of the testing. The D15d and FM100 color vision arrangement tests were applied in a population of 36 (22 males) and 42 (25 males), respectively. Controls were healthy volunteers from the cities of São Paulo for the D15d and Belém for the FM100. There was a statistically significant difference in performance between those who were exposed and controls for both tests (p < 0.01 and p < 0.0001, respectively, Mann-Whitney U test), meaning that adults living in this region of the Amazon made more mistakes on both tests when compared to controls. A linear regression was performed using Hg concentrations and test scores. Hg concentrations accounted for 7% and 2% of color D15d and FM100 arrangement test errors, respectively. Although other studies have previously found color vision impairment in the Amazon, they tested inhabitants on the east side of the Amazon, while this study was conducted in the central Amazon region and it is the first study in a population with no direct contact with the Hg source of contamination. These results suggest that long-term exposure to low-level methylmercury in riverside populations is more widely spread in the Amazon Basin than previously reported. This information is needed to implement public health policies that will ensure a safer environment for the Amazonian population. Copyright © 2018 Elsevier B.V. All rights reserved.
The Road to Certainty and Back.
Westheimer, Gerald
2016-10-14
The author relates his intellectual journey from eye-testing clinician to experimental vision scientist. Starting with the quest for underpinning in physics and physiology of vague clinical propositions and of psychology's acceptance of thresholds as "fuzzy-edged," and a long career pursuing a reductionist agenda in empirical vision science, his journey led to the realization that the full understanding of human vision cannot proceed without factoring in an observer's awareness, with its attendant uncertainty and open-endedness. He finds support in the loss of completeness, finality, and certainty revealed in fundamental twentieth-century formulations of mathematics and physics. Just as biology prospered with the introduction of the emergent, nonreductionist concepts of evolution, vision science has to become comfortable accepting data and receiving guidance from human observers' conscious visual experience.
2015-01-01
Purpose. There is a need for efficient self-tests of vision in patients with neovascular age-related macula degeneration. A new tablet/smartphone application aiming to meet this need is described and its performance is assessed in a longitudinal pilot study. Materials and Methods. The new MultiBit Test (MBT) employs segmented digits defined by rarebits, that is, receptive field-size bright dots briefly presented against a dark background. The number of rarebits per digit segment was varied in a cyclic fashion, in preset steps. There were no fixation demands. Twenty-eight patients with neovascular AMD of varying severity were monitored for an average of 30 weeks. Test scores were evaluated on an individual basis, by contrasting observed trends with the clinical status recorded at independently scheduled clinical examinations. Results. Serial plots of MBT results revealed gradual improvement after successful antineovascular treatment. Recurrences were signalled by gradual deteriorations of results. Test results remained stable during clinically stable time intervals. MBT results agreed well with clinical assessments whereas an acuity test performed at chance level. The MBT was well accepted by all subjects. Conclusions. The MBT appears to have a good potential for effective self-testing of vision in AMD and merits large-scale studies. Exploration of MBT performance with other forms of macula conditions may be worthwhile. PMID:26124958
Lack of international uniformity in assessing color vision deficiency in professional pilots.
Watson, Dougal B
2014-02-01
Color is an important characteristic of the aviation environment. Pilots must rapidly and accurately differentiate and identify colors. The medical standards published by the International Civil Aviation Organization (ICAO) require that pilots have "the ability to perceive readily those colors the perception of which is necessary for the safe performance of duties." The general wording of that color vision (CV) standard, coupled with the associated flexibility provisions, allows for different approaches to the assessment of color vision deficient (CVD) pilots. Data was gathered and analyzed regarding medical assessment practices applied by different countries to CVD pilots. Data was obtained from 78 countries, representing 78% of the population and 92% of the aviation activity of the world. That data indicates wide variation in the medical assessment of CVD pilots. Countries use different tools and procedures for the testing of pilots, and also apply different result criteria to those tests. At one extreme an applicant making one error upon Ishihara 24-plate pseudoisochromatic plate (PIP) testing is declined a class 1 medical assessment, while at another extreme an applicant failing every color vision test required by the regulatory authority may be issued a medical assessment allowing commercial and airline copilot privileges. The medical assessment of CVD applicants is not performed consistently across the world. Factors that favor uniformity have been inadequate to encourage countries toward consistent medical assessment outcomes. This data is not consistent with the highest practicable degree of uniformity in medical assessment outcomes, and encourages aeromedical tourism.
Cole, Barry L; Harris, Ross W
2009-09-01
The aim was to make a posthumous diagnosis of the abnormal colour vision of the acclaimed artist Clifton Pugh and to analyse his use of colours to discern the strategies he used to overcome his limited colour perception. A pedigree of Pugh's family was constructed by searching public records. Pugh had no daughters but he had two older brothers, one of whom was still living. We tested the colour vision of this brother and one of his daughters and one of his grandsons. Three children of the other brother were questioned about the colour vision of their father and one daughter was tested for heterozygosity with the Medmont C100. Four observers with normal colour vision categorised the colours used by Pugh in a sample of 59 of his paintings. Protanopic transformations of some of these paintings were made using the Vischeck algorithms to gain an appreciation of how Pugh saw his own paintings. The validity of the transformations was tested by asking a protanope to report if the transformations looked the same as the normal colour images of 10 of Pugh's paintings. Pugh's brother was a severe protan. His daughter showed Schmidt's sign and was a carrier of the protan gene and her son was a protanope. The oldest brother was reported as having normal colour vision. Therefore, it is almost certain that Clifton Pugh was a protanope. Pugh used all colours in his paintings but preferred to structure them on brown, black and blue or, for high key paintings, on cream or flesh colours. He used greens and purples sparingly. The protanopic Vischeck transformations did not always look the same as the normal colour image for the protanope observer. A severe colour vision deficiency does not preclude success as a painter. It is a handicap but there are strategies artists can use to overcome it.
Vision screening with the RDE stereotest in pediatric populations.
Schmidt, P P
1994-04-01
The usefulness of the Random Dot E (RDE) stereotest in screening the vision of school-aged children for vision problems has been established. As a single screening procedure, the effectivity (phi) of the RDE (phi = +0.52) is greater than the widely used Snellen acuity technique (phi = +0.36) and faster to complete. Very-low-birthweight (VLBW) children have a higher incidence of vision problems including strabismus, amblyopia, and refractive error than children born with normal-birthweights (NBW's). My purpose was to determine: (1) whether a group of young children at high risk for vision problems could perform random dot stereotesting and (2) an age appropriate pass/fail criterion for stereoacuity screening. Furthermore, categorization as pass or fail by each screening method studied [stereoacuity (RDE), visual acuity [Teller Acuity Cards (TAC) and Broken Wheel (BWA)] and refractive error] was compared for independent agreement with vision examination results. The subjects were a cohort of NBW and VLBW) (< 1500 g) children matched at birth for maternal age, ethnic origin, time of hospital birth, and parity. Results of a masked investigation of 30 children [VLBW (N = 10) and NBW (N = 20) children] tested at 3 years of age (mean age = 3.0 years, range 2.11 to 3.1 years) showed that (1) 86.7% were able to complete the 168 sec arc random dot stereoacuity task when a two-alternative forced-choice preferential-looking paradigm was used for testing, (2) the specificity and sensitivity were 88.2%, 76.9% (RDE); 81.2%, 64.3% (TAC); 52.9%, 92.3% (BWA); and 94.1%, 61.5% (refractive error), respectively, (3) the reliability the RDE stereoacuity screening was greater (k = +0.66) than any of the other procedures studied, and (4) there was 73.3% agreement on test-retest categorizations between observers.(ABSTRACT TRUNCATED AT 250 WORDS)
[Visual function evaluation in human immunodeficiency virus carriers].
Solís-Castillo, A; Ramírez-Ponce, L A; Valdez-González, T; Seijo, E; Voorduin-Ramos, S; López-Star, E M
2011-04-01
To determine whether there are changes in the peripapillary nerve fibre layer, in colour vision, contrast sensitivity, dark adaptation and electroretinography changes in these patients who do not have infectious retinitis. We studied 52 patients without ocular pathology; the mean age was 35.88 years old. We observed less thickness in all quadrants, except the nasal. The colour vision was altered in 27.77% of the patients. The contrast sensitivity test showed high frequency alterations. There was no statistically significant difference in the electroretinography test or in dark adaptation. There are changes in the peripapillary nerve fibre layer thickness; also we found changes in colour vision, contrast sensitivity and a decreasing trend of the B wave in the electroreninogram. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Bratzke, Daniel; Seifried, Tanja; Ulrich, Rolf
2012-08-01
This study assessed possible cross-modal transfer effects of training in a temporal discrimination task from vision to audition as well as from audition to vision. We employed a pretest-training-post-test design including a control group that performed only the pretest and the post-test. Trained participants showed better discrimination performance with their trained interval than the control group. This training effect transferred to the other modality only for those participants who had been trained with auditory stimuli. The present study thus demonstrates for the first time that training on temporal discrimination within the auditory modality can transfer to the visual modality but not vice versa. This finding represents a novel illustration of auditory dominance in temporal processing and is consistent with the notion that time is primarily encoded in the auditory system.
Abu Bakar, Nurul Farhana; Chen, Ai-Hong
2014-01-01
Context: Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. Aims: The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. Materials and Methods: A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. ‘Unable to test’ was defined as inappropriate response or uncooperative despite best efforts of the screener. Results: The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes (P < 0.001) but not in Cambridge Crowding Cards, Lang Stereo test II and CVTME. Conclusion: Non verbal or “matching” approaches were found to be more superior in testing visual functions in children with learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities. PMID:24008790
Evaluation of 5 different labeled polymer immunohistochemical detection systems.
Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A
2010-01-01
Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.
Vision Tests For Medical Surveillance Or To Insure Job Fitness
NASA Astrophysics Data System (ADS)
Wolbarsht, M. L.; Landers, M. B.
1986-05-01
The rationale for designing screening type eye examinations to document visual capabilities for specific jobs or changes in visual function following exposure to specific ocular hazards is discussed. Possible applications to clinical situations are also discussed. Specific tests meeting requirements of definite end point quantification, ease of administration, and reproducibility are given for contrast (glare) sensitivity, distortions in macular imaging (Amsler grid), and color vision. The selection is aetailed for tne individual test combinations of various populations such as automobile uriver license applicants, visual display operators, and persons exposed to lasers, including military as well as non-military installers and repairers of optical fibers for communications.
Torres-Oviedo, Gelsy; Bastian, Amy J
2010-12-15
Devices such as robots or treadmills are often used to drive motor learning because they can create novel physical environments. However, the learning (i.e., adaptation) acquired on these devices only partially generalizes to natural movements. What determines the specificity of motor learning, and can this be reliably made more general? Here we investigated the effect of visual cues on the specificity of split-belt walking adaptation. We systematically removed vision to eliminate the visual-proprioceptive mismatch that is a salient cue specific to treadmills: vision indicates that we are not moving while leg proprioception indicates that we are. We evaluated the adaptation of temporal and spatial features of gait (i.e., timing and location of foot landing), their transfer to walking over ground, and washout of adaptation when subjects returned to the treadmill. Removing vision during both training (i.e., on the treadmill) and testing (i.e., over ground) strongly improved the transfer of treadmill adaptation to natural walking. Removing vision only during training increased transfer of temporal adaptation, whereas removing vision only during testing increased the transfer of spatial adaptation. This dissociation reveals differences in adaptive mechanisms for temporal and spatial features of walking. Finally training without vision increased the amount that was learned and was linked to the variability in the behavior during adaptation. In conclusion, contextual cues can be manipulated to modulate the magnitude, transfer, and washout of device-induced learning in humans. These results bring us closer to our ultimate goal of developing rehabilitation strategies that improve movements beyond the clinical setting.
Development of a Wireless Computer Vision Instrument to Detect Biotic Stress in Wheat
Casanova, Joaquin J.; O'Shaughnessy, Susan A.; Evett, Steven R.; Rush, Charles M.
2014-01-01
Knowledge of crop abiotic and biotic stress is important for optimal irrigation management. While spectral reflectance and infrared thermometry provide a means to quantify crop stress remotely, these measurements can be cumbersome. Computer vision offers an inexpensive way to remotely detect crop stress independent of vegetation cover. This paper presents a technique using computer vision to detect disease stress in wheat. Digital images of differentially stressed wheat were segmented into soil and vegetation pixels using expectation maximization (EM). In the first season, the algorithm to segment vegetation from soil and distinguish between healthy and stressed wheat was developed and tested using digital images taken in the field and later processed on a desktop computer. In the second season, a wireless camera with near real-time computer vision capabilities was tested in conjunction with the conventional camera and desktop computer. For wheat irrigated at different levels and inoculated with wheat streak mosaic virus (WSMV), vegetation hue determined by the EM algorithm showed significant effects from irrigation level and infection. Unstressed wheat had a higher hue (118.32) than stressed wheat (111.34). In the second season, the hue and cover measured by the wireless computer vision sensor showed significant effects from infection (p = 0.0014), as did the conventional camera (p < 0.0001). Vegetation hue obtained through a wireless computer vision system in this study is a viable option for determining biotic crop stress in irrigation scheduling. Such a low-cost system could be suitable for use in the field in automated irrigation scheduling applications. PMID:25251410
Quantification of color vision using a tablet display.
Chacon, Alicia; Rabin, Jeff; Yu, Dennis; Johnston, Shawn; Bradshaw, Timothy
2015-01-01
Accurate color vision is essential for optimal performance in aviation and space environments using nonredundant color coding to convey critical information. Most color tests detect color vision deficiency (CVD) but fail to diagnose type or severity of CVD, which are important to link performance to occupational demands. The computer-based Cone Contrast Test (CCT) diagnoses type and severity of CVD. It is displayed on a netbook computer for clinical application, but a more portable version may prove useful for deployments, space and aviation cockpits, as well as accident and sports medicine settings. Our purpose was to determine if the CCT can be conducted on a tablet display (Windows 8, Microsoft, Seattle, WA) using touch-screen response input. The CCT presents colored letters visible only to red (R), green (G), and blue (B) sensitive retinal cones to determine the lowest R, G, and B cone contrast visible to the observer. The CCT was measured in 16 color vision normals (CVN) and 16 CVDs using the standard netbook computer and a Windows 8 tablet display calibrated to produce equal color contrasts. Both displays showed 100% specificity for confirming CVN and 100% sensitivity for detecting CVD. In CVNs there was no difference between scores on netbook vs. tablet displays. G cone CVDs showed slightly lower G cone CCT scores on the tablet. CVD can be diagnosed with a tablet display. Ease-of-use, portability, and complete computer capabilities make tablets ideal for multiple settings, including aviation, space, military deployments, accidents and rescue missions, and sports vision. Chacon A, Rabin J, Yu D, Johnston S, Bradshaw T. Quantification of color vision using a tablet display.
Kalt, Wilhelmina; McDonald, Jane E; Fillmore, Sherry A E; Tremblay, Francois
2014-11-19
Clinical evidence for anthocyanin benefits in night vision is controversial. This paper presents two human trials investigating blueberry anthocyanin effects on dark adaptation, functional night vision, and vision recovery after retinal photobleaching. One trial, S2 (n = 72), employed a 3 week intervention and a 3 week washout, two anthocyanin doses (271 and 7.11 mg cyanidin 3-glucoside equivalents (C3g eq)), and placebo. The other trial, L1 (n = 59), employed a 12 week intervention and an 8 week washout and tested one dose (346 mg C3g eq) and placebo. In both S2 and L1 neither dark adaptation nor night vision was improved by anthocyanin intake. However, in both trials anthocyanin consumption hastened the recovery of visual acuity after photobleaching. In S2 both anthocyanin doses were effective (P = 0.014), and in L1 recovery was improved at 8 weeks (P = 0.027) and 12 weeks (P = 0.030). Although photobleaching recovery was hastened by anthocyanins, it is not known whether this improvement would have an impact on everyday vision.
NASA Technical Reports Server (NTRS)
Ettinger, Scott M.; Nechyba, Michael C.; Ifju, Peter G.; Wazak, Martin
2002-01-01
Substantial progress has been made recently towards design building and test-flying remotely piloted Micro Air Vehicle's (MAVs). We seek to complement this progress in overcoming the aerodynamic obstacles to.flight at very small scales with a vision stability and autonomy system. The developed system based on a robust horizon detection algorithm which we discuss in greater detail in a companion paper. In this paper, we first motivate the use of computer vision for MAV autonomy arguing that given current sensor technology, vision may he the only practical approach to the problem. We then briefly review our statistical vision-based horizon detection algorithm, which has been demonstrated at 30Hz with over 99.9% correct horizon identification. Next we develop robust schemes for the detection of extreme MAV attitudes, where no horizon is visible, and for the detection of horizon estimation errors, due to external factors such as video transmission noise. Finally, we discuss our feed-back controller for self-stabilized flight, and report results on vision autonomous flights of duration exceeding ten minutes.
Colour blindness in everyday life and car driving.
Tagarelli, Antonio; Piro, Anna; Tagarelli, Giuseppe; Lantieri, Pasquale Bruno; Risso, Domenico; Olivieri, Rosario Luciano
2004-08-01
The aim of the present work was to ascertain, through the administration of a psychosocial questionnaire, the difficulties that subjects with defective colour vision experience in carrying out everyday tasks and work, including driving a car with a driver's licence held for no more than 3 years. Subjects with defective colour vision (n = 151) and subjects with normal vision (n = 302) completed a psychosocial questionnaire regarding the difficulties associated with congenital colour vision deficiency in daily life, work and driving a car. Subjects were diagnosed as colour-blind using the Ishihara test. Statistically significant differences between the two samples were found for daily life activities. Subjects with defective colour vision preferred daytime driving. At night, subjects with defective colour vision had difficulty identifying reflectors on the road and the rear signal lights of cars ahead of them. Colour-blind Calabrian subjects admitted to experiencing colour-related difficulties with a wide range of occupational tasks and leisure pursuits. In particular, colour-blind Calabrian subjects preferred daytime driving, and fewer drove regularly, compared to orthochromatics, who were indifferent to night or daytime driving.
Three-dimensional vision enhances task performance independently of the surgical method.
Wagner, O J; Hagen, M; Kurmann, A; Horgan, S; Candinas, D; Vorburger, S A
2012-10-01
Within the next few years, the medical industry will launch increasingly affordable three-dimensional (3D) vision systems for the operating room (OR). This study aimed to evaluate the effect of two-dimensional (2D) and 3D visualization on surgical skills and task performance. In this study, 34 individuals with varying laparoscopic experience (18 inexperienced individuals) performed three tasks to test spatial relationships, grasping and positioning, dexterity, precision, and hand-eye and hand-hand coordination. Each task was performed in 3D using binocular vision for open performance, the Viking 3Di Vision System for laparoscopic performance, and the DaVinci robotic system. The same tasks were repeated in 2D using an eye patch for monocular vision, conventional laparoscopy, and the DaVinci robotic system. Loss of 3D vision significantly increased the perceived difficulty of a task and the time required to perform it, independently of the approach (P < 0.0001-0.02). Simple tasks took 25 % to 30 % longer to complete and more complex tasks took 75 % longer with 2D than with 3D vision. Only the difficult task was performed faster with the robot than with laparoscopy (P = 0.005). In every case, 3D robotic performance was superior to conventional laparoscopy (2D) (P < 0.001-0.015). The more complex the task, the more 3D vision accelerates task completion compared with 2D vision. The gain in task performance is independent of the surgical method.
DOT National Transportation Integrated Search
1975-01-01
Scores on the American Optical Company (AOC) test (1965 edition), Dvorine test, Farnsworth Lantern test, Color Threshold Tester, Farnsworth-Munsell 100-Hue test, Farnsworth Panel D-15 test, and Schmidt-Haensch Anomaloscope were obtained from 137 men ...
Photographic Assessment of Dark Spots in Night Vision Device Images
1998-01-01
Ronchi, V., (1957), Optics, the science of vision, New York: New York University Press. BIOGRAPHY Peter L. Marasco came to the U.S. Air Force in 1991 as a...optical test methods. Mr. Marasco received a BS degree from the University of Rochester in 1991 and an MS degree from the University of Arizona in 1993
Testing the Vision: Preschool Settings as Places for Meeting, Bonding and Bridging
ERIC Educational Resources Information Center
Thorpe, Karen; Staton, Sally; Morgan, Robert; Danby, Susan; Tayler, Collette
2012-01-01
The OECD (2006 Starting Strong II: Early Childhood Education and Care. OECD Publishing: Paris) envisions early childhood education and care settings as meeting places for diverse social groups; places that build social capital. This vision was assessed in a comparison of three preschools types: full-fee paying, subsidised-fee and publicly funded.…
What is stereoscopic vision good for?
NASA Astrophysics Data System (ADS)
Read, Jenny C. A.
2015-03-01
Stereo vision is a resource-intensive process. Nevertheless, it has evolved in many animals including mammals, birds, amphibians and insects. It must therefore convey significant fitness benefits. It is often assumed that the main benefit is improved accuracy of depth judgments, but camouflage breaking may be as important, particularly in predatory animals. In humans, for the last 150 years, stereo vision has been turned to a new use: helping us reproduce visual reality for artistic purposes. By recreating the different views of a scene seen by the two eyes, stereo achieves unprecedented levels of realism. However, it also has some unexpected effects on viewer experience. The disruption of established mechanisms for interpreting pictures may be one reason why some viewers find stereoscopic content disturbing. Stereo vision also has uses in ophthalmology. Clinical stereoacuity tests are used in the management of conditions such as strabismus and amblyopia as well as vision screening. Stereoacuity can reveal the effectiveness of therapy and even predict long-term outcomes post surgery. Yet current clinical stereo tests fall far short of the accuracy and precision achievable in the lab. At Newcastle University, we are exploiting the recent availability of autostereo 3D tablet computers to design a clinical stereotest app in the form of a game suitable for young children. Our goal is to enable quick, accurate and precise stereoacuity measures which will enable clinicians to obtain better outcomes for children with visual disorders.
Delhey, Kaspar; Hall, Michelle; Kingma, Sjouke A.; Peters, Anne
2013-01-01
Colour signals are expected to match visual sensitivities of intended receivers. In birds, evolutionary shifts from violet-sensitive (V-type) to ultraviolet-sensitive (U-type) vision have been linked to increased prevalence of colours rich in shortwave reflectance (ultraviolet/blue), presumably due to better perception of such colours by U-type vision. Here we provide the first test of this widespread idea using fairy-wrens and allies (Family Maluridae) as a model, a family where shifts in visual sensitivities from V- to U-type eyes are associated with male nuptial plumage rich in ultraviolet/blue colours. Using psychophysical visual models, we compared the performance of both types of visual systems at two tasks: (i) detecting contrast between male plumage colours and natural backgrounds, and (ii) perceiving intraspecific chromatic variation in male plumage. While U-type outperforms V-type vision at both tasks, the crucial test here is whether U-type vision performs better at detecting and discriminating ultraviolet/blue colours when compared with other colours. This was true for detecting contrast between plumage colours and natural backgrounds (i), but not for discriminating intraspecific variability (ii). Our data indicate that selection to maximize conspicuousness to conspecifics may have led to the correlation between ultraviolet/blue colours and U-type vision in this clade of birds. PMID:23118438
Chromatic VEP in children with congenital colour vision deficiency.
Tekavčič Pompe, Manca; Stirn Kranjc, Branka; Brecelj, Jelka
2010-09-01
Visual evoked potentials to chromatic stimulus (cVEP) are believed to selectively test the parvocellular visual pathway which is responsible for processing information about colour. The aim was to evaluate cVEP in children with red-green congenital colour vision deficiency. VEP responses of 15 colour deficient children were compared to 31 children with normal colour vision. An isoluminant red-green stimulus composed of horizontal gratings was presented in an onset-offset manner. The shape of the waveform was studied, as well as the latency and amplitude of positive (P) and negative (N) waves. cVEP response did not change much with increased age in colour deficient children, whereas normative data showed changes from a predominantly positive to a negative response with increased age. A P wave was present in 87% of colour deficient children (and in 100% of children with normal colour vision), whereas the N wave was absent in a great majority of colour deficient children and was present in 80% of children with normal colour vision. Therefore, the amplitude of the whole response (N-P) decreased linearly with age in colour deficient children, whereas in children with normal colour vision it increased linearly. P wave latency shortened with increased age in both groups. cVEP responses differ in children with congenital colour vision deficiency compared to children with normal colour vision. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.
Ekici, Feyzahan; Loh, Rebecca; Waisbourd, Michael; Sun, Yi; Martinez, Patricia; Nayak, Natasha; Wizov, Sheryl S; Hegarty, Sarah; Hark, Lisa A; Spaeth, George L
2015-12-01
To our knowledge, few studies have combined an objective measure of vision-related performance (VRP) and subjective measures of vision-related quality of life (VRQoL) with clinically related visual parameters, particularly in a large, prospective, cohort study setting. To examine the relationships between clinical visual assessments and both a VRP and 2 self-reported VRQoL measurements. Patients (N = 161) with moderate-stage glaucoma recruited from the Glaucoma Service at Wills Eye Hospital, Philadelphia, Pennsylvania, were enrolled from May 2012 to May 2014 in an ongoing prospective, 4-year longitudinal observational study. This report includes cross-sectional results from the baseline visit. Patients received a complete ocular examination, automated visual field (VF) test and Cirrus optical coherence tomographic scan. Contrast sensitivity was measured with the Pelli-Robson and the Spaeth-Richman Contrast Sensitivity (SPARCS) tests. Vision-related performance was assessed by the Compressed Assessment of Ability Related to Vision (CAARV) test. Vision-related QoL was assessed by the National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ-25) and a modified Glaucoma Symptom Scale (MGSS). Correlations between clinical measures and CAARV, NEI-VFQ-25, and MGSS scores. A total of 161 patients were enrolled in the study. The strongest correlation was found between SPARCS score in the better eye and total CAARV score (r = 0.398; 95% CI, 0.235-0.537; P < .001). The CAARV score also correlated with the Pelli-Robson score (r = 0.353; 95% CI, 0.186-0.499; P = .001), VF mean deviation (r = 0.366; 95% CI, 0.200-0.510; P < .001), and VA (r = -0.326, 95% CI = -0.476 to -0.157; P = .003) in the better eye. There were more statistically significant correlations between contrast sensitivity tests and VF mean deviation with VRQoL measurements than with other clinical measures (visual acuity, intraocular pressure, Disc Damage Likelihood Scale, and mean retinal nerve fiber layer thickness). The MGSS scores were lower (worse) in women compared with men (P = .03 for binocular, P = .01 for better eye, and P = .05 for the worse eye). Structural measures (eg, Disc Damage Likelihood Scale, and retinal nerve fiber layer thickness) were generally not informative with respect to VRP or VRQoL. Contrast sensitivity tests and VF mean deviation were associated with both objective measures of the ability to act and subjective measurements of VRQoL. The strongest correlation was between SPARCS score (contrast sensitivity) in the better eye and total CAARV score. Therefore, measurement of contrast sensitivity should be considered when evaluating patients' VRQoL. The results of this study were limited by the patient population and apply only within the bounds of the tested cohort.
Long Duration Head-Down Tilt Bed Rest Studies: Safety Considerations Regarding Vision Health
NASA Technical Reports Server (NTRS)
Cromwell, Ronita L.; Zanello, S. B.; Yarbough, P. O.; Ploutz-Snyder, Robert; Taibbi, G.; Vizzeri, G.
2012-01-01
Visual symptoms reported in astronauts returning from long duration missions in low Earth orbit, including hyperopic shift, choroidal folds, globe flattening and papilledema, are thought to be related to fluid shifts within the body due to microgravity exposure. Because of this possible relation to fluid shifts, safety considerations have been raised regarding the ocular health of head-down tilt (HDT) bed rest subjects. HDT is a widely used ground ]based analog that simulates physiological changes of spaceflight, including fluid shifts. Thus, vision monitoring has been performed in bed rest subjects in order to evaluate the safety of HDT with respect to vision health. Here we report ocular outcomes in 9 healthy subjects (age range: 27-48 years; Male/Female ratio: 8/1) completing bed rest Campaign 11, an integrated, multidisciplinary 70-day 6 degrees HDT bed rest study. Vision examinations were performed on a weekly basis, and consisted of office-based (2 pre- and 2 post-bed rest) and in-bed testing. The experimental design was a repeated measures design, with measurements for both eyes taken for each subject at each planned time point. Findings for the following tests were all reported as normal in each testing session for every subject: modified Amsler grid, red dot test, confrontational visual fields, color vision and fundus photography. Overall, no statistically significant differences were observed for any of the measures, except for both near and far visual acuity, which increased during the course of the study. This difference is not considered clinically relevant as may result from the effect of learning. Intraocular pressure results suggest a small increase at the beginning of the bed rest phase (p=0.059) and lesser increase at post-bed rest with respect to baseline (p=0.046). These preliminary results provide the basis for further analyses that will include correlations between intraocular pressure change pre- and post-bed rest, and optical coherence tomography measurements of the retina.
Vision Examination Protocol for Archery Athletes Along With an Introduction to Sports Vision
Mohammadi, Seyed Farzad; Aghazade Amiri, Mohammad; Naderifar, Homa; Rakhshi, Elham; Vakilian, Banafsheh; Ashrafi, Elham; Behesht-Nejad, Amir-Houshang
2016-01-01
Introduction: Visual skills are one of the main pillars of intangible faculties of athletes that can influence their performance. Great number of vision tests used to assess the visual skills and it will be irrational to perform all vision tests for every sport. Objectives: The purpose of this protocol article is to present a relatively comprehensive battery of tests and assessments on static and dynamic aspects of sight which seems relevant to sports vision and introduce the most useful ones for archery. Materials and Methods: Through extensive review of the literature, visual skills and respective tests were listed; such as ‘visual acuity, ‘contrast sensitivity’, ‘stereo-acuity’, ‘ocular alignment’, and ‘eye dominance’. Athletes were defined as “elite” and “non-elite” category based on their past performance. Dominance was considered for eye and hand; binocular or monocular aiming was planned to be recorded. Illumination condition was defined as to simulate the real archery condition to the extent possible. The full cycle of examinations and their order for each athlete was sketched (and estimated to take 40 minutes). Protocol was piloted in an eye hospital. Female and male archers aged 18 - 38 years who practiced compound and recurve archery with a history of more than 6 months were included. Conclusions: We managed to select and design a customized examination protocol for archery (a sight-intensive and aiming type of sports), serving skill assessment and research purposes. Our definition for elite and non-elite athletes can help to define sports talent and devise skill development methods as we compare the performance of these two groups. In our pilot, we identified 8 “archery figures” (by hand dominance, eye dominance and binocularity) and highlighted the concept “congruence” (dominant hand and eye in the same side) in archery performance. PMID:27217923
Ling, Barbara Y; Dain, Stephen J
2018-04-01
Nonvisual demands of tests affect vision test results in children. 150 children (79 females and 71 males, 5.3-12.7 years of age) were examined. Isoluminant Blue, Yellow, Red, Green, and Black and White thresholds were established with a four-alternative forced-choice and pseudo-10-bit system with adaptive staircase and gaming elements. Where Threshold=b 0 +b 1 *age -1 , b 1 for RG=6.26±1.90 (95% confidence limits), Achr=3.96±1.07 and BY=12.48±2.76 were significantly different. The noncolor demands of the test are the same for RG, BY, and Achr, so the later development of BY discrimination is not an artifact of the test.
Ying, Gui-shuang; Maguire, Maureen; Quinn, Graham; Kulp, Marjean Taylor; Cyert, Lynn
2011-12-28
To evaluate, by receiver operating characteristic (ROC) analysis, the accuracy of three instruments of refractive error in detecting eye conditions among 3- to 5-year-old Head Start preschoolers and to evaluate differences in accuracy between instruments and screeners and by age of the child. Children participating in the Vision In Preschoolers (VIP) Study (n = 4040), had screening tests administered by pediatric eye care providers (phase I) or by both nurse and lay screeners (phase II). Noncycloplegic retinoscopy (NCR), the Retinomax Autorefractor (Nikon, Tokyo, Japan), and the SureSight Vision Screener (SureSight, Alpharetta, GA) were used in phase I, and Retinomax and SureSight were used in phase II. Pediatric eye care providers performed a standardized eye examination to identify amblyopia, strabismus, significant refractive error, and reduced visual acuity. The accuracy of the screening tests was summarized by the area under the ROC curve (AUC) and compared between instruments and screeners and by age group. The three screening tests had a high AUC for all categories of screening personnel. The AUC for detecting any VIP-targeted condition was 0.83 for NCR, 0.83 (phase I) to 0.88 (phase II) for Retinomax, and 0.86 (phase I) to 0.87 (phase II) for SureSight. The AUC was 0.93 to 0.95 for detecting group 1 (most severe) conditions and did not differ between instruments or screeners or by age of the child. NCR, Retinomax, and SureSight had similar and high accuracy in detecting vision disorders in preschoolers across all types of screeners and age of child, consistent with previously reported results at specificity levels of 90% and 94%.
Ni, W; Li, X; Hou, Z; Zhang, H; Qiu, W; Wang, W
2015-01-01
Purpose Real-Life Vision Test (RLVT) is a newly developed performance-based measures of functional vision. This present study is designed to determine whether it could be a meaningful assessment for cataract surgery outcomes evaluation. Patients and methods Age-related cataract patients (56) who scheduled for bilateral cataract surgery and 44 age-matched controls were evaluated by four types of measurements: (1) demographic, medical, cognitive and depressive evaluation, and the reaction time testing; (2) clinical measures (visual acuity, contrast sensitivity, stereopsis, and color perception); (3) the 25-item National Eye Institute's Visual Functioning Questionnaire (NEI-VFQ); (4) the RLVT. Spearman's coefficients and multiple regression analysis were conducted to investigate the relationship among RLVT, clinical measures, and self-report assessment of visual function. Results The results of RLVT, clinical measures, and NEI-VFQ total scores were improved significantly after cataract surgery. There were no differences between control subjects and post-surgery patients with respect to NEI-VFQ-25 total scores, self-rating depression scale scores and three tasks of RLVT. Change of RLVT was significantly associated with the change of clinical measures in the cataract group. Multiple regression analysis demonstrated that change of distance, intermediate, and near visual acuity, and binocular contrast sensitivity were significant predictors of improvements of RLVT. Conclusions Cataract surgery could improve real-world visual ability effectively for cataract patients. Our study highlights the potential usefulness of RLVT as an adjunct to the current outcomes evaluation system for cataract surgery. The use of RLVT combined with clinical and self-survey methods may be the comprehensive strategy to manifest the impact of cataract surgery on patients' overall vision-related quality of life. PMID:26272444
Visual function of police officers who have undergone refractive surgery.
Hovis, Jeffery K; Ramaswamy, Shankaran
2006-11-01
The visual acuity and contrast sensitivity of police recruits and officers was evaluated in both normal and dim illumination conditions to determine whether officers who have had refractive surgery have compromised night vision. The control group consisted of 76 officers and recruits who have not had refractive surgery and the refractive surgery group consisted of 22 officers and recruits who had refractive surgery. Visual acuity and contrast sensitivity were measured under both room illumination and dim illumination. The room illumination test series included high contrast acuity, low contrast acuity and Pelli-Robson contrast sensitivity. The dim illumination test series included high contrast acuity, low contrast acuity, Pelli-Robson contrast sensitivity, license plate number acuity (with and without glare) and the Mesotest. The general findings were that the refractive surgery group had lower acuity scores on low contrast targets in both room and dim light levels along with a reduction in the Mesotest scores with a glare source compared to the control group. Although refractive surgery police recruits and officers had reduced performance on some vision tests, these reductions were small and it is unlikely that their performance on vision related tasks would be compromised, on average. The major concern is the small number of refractive surgery candidates whose results were well outside the range of the non-surgical candidates. Their vision may be unacceptable for policing. Copyright (c) 2006 Wiley-Liss, Inc.
Job-shop scheduling applied to computer vision
NASA Astrophysics Data System (ADS)
Sebastian y Zuniga, Jose M.; Torres-Medina, Fernando; Aracil, Rafael; Reinoso, Oscar; Jimenez, Luis M.; Garcia, David
1997-09-01
This paper presents a method for minimizing the total elapsed time spent by n tasks running on m differents processors working in parallel. The developed algorithm not only minimizes the total elapsed time but also reduces the idle time and waiting time of in-process tasks. This condition is very important in some applications of computer vision in which the time to finish the total process is particularly critical -- quality control in industrial inspection, real- time computer vision, guided robots. The scheduling algorithm is based on the use of two matrices, obtained from the precedence relationships between tasks, and the data obtained from the two matrices. The developed scheduling algorithm has been tested in one application of quality control using computer vision. The results obtained have been satisfactory in the application of different image processing algorithms.
Smart Camera System for Aircraft and Spacecraft
NASA Technical Reports Server (NTRS)
Delgado, Frank; White, Janis; Abernathy, Michael F.
2003-01-01
This paper describes a new approach to situation awareness that combines video sensor technology and synthetic vision technology in a unique fashion to create a hybrid vision system. Our implementation of the technology, called "SmartCam3D" (SC3D) has been flight tested by both NASA and the Department of Defense with excellent results. This paper details its development and flight test results. Windshields and windows add considerable weight and risk to vehicle design, and because of this, many future vehicles will employ a windowless cockpit design. This windowless cockpit design philosophy prompted us to look at what would be required to develop a system that provides crewmembers and awareness. The system created to date provides a real-time operations personnel an appropriate level of situation 3D perspective display that can be used during all-weather and visibility conditions. While the advantages of a synthetic vision only system are considerable, the major disadvantage of such a system is that it displays the synthetic scene created using "static" data acquired by an aircraft or satellite at some point in the past. The SC3D system we are presenting in this paper is a hybrid synthetic vision system that fuses live video stream information with a computer generated synthetic scene. This hybrid system can display a dynamic, real-time scene of a region of interest, enriched by information from a synthetic environment system, see figure 1. The SC3D system has been flight tested on several X-38 flight tests performed over the last several years and on an ARMY Unmanned Aerial Vehicle (UAV) ground control station earlier this year. Additional testing using an assortment of UAV ground control stations and UAV simulators from the Army and Air Force will be conducted later this year.
Quality Control by Artificial Vision
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lam, Edmond Y.; Gleason, Shaun Scott; Niel, Kurt S.
2010-01-01
Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papersmore » relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier-basis functions for this task. Image registration is another important task for machine vision. Bingham and Arrowood investigate the implementation and results in applying Fourier phase matching for projection registration, with a particular focus on nondestructive testing using computed tomography. Readers interested in enriching their arsenal of image-processing algorithms for machine-vision tasks should find these papers enriching. Meanwhile, we have four papers dealing with more specific machine-vision tasks. The first one, Yahiaoui et al., is quantitative in nature, using machine vision for real-time passenger counting. Occulsion is a common problem in counting objects and people, and they circumvent this issue with a dense stereovision system, achieving 97 to 99% accuracy in their tests. On the other hand, the second paper by Oswald-Tranta et al. focuses on thermographic crack detection. An infrared camera is used to detect inhomogeneities, which may indicate surface cracks. They describe the various steps in developing fully automated testing equipment aimed at a high throughput. Another paper describing an inspection system is Molleda et al., which handles flatness inspection of rolled products. They employ optical-laser triangulation and 3-D surface reconstruction for this task, showing how these can be achieved in real time. Last but not least, Presles et al. propose a way to monitor the particle-size distribution of batch crystallization processes. This is achieved through a new in situ imaging probe and image-analysis methods. While it is unlikely any reader may be working on these four specific problems at the same time, we are confident that readers will find these papers inspiring and potentially helpful to their own machine-vision system developments.« less
Low vision in east African blind school students: need for optical low vision services.
Silver, J; Gilbert, C E; Spoerer, P; Foster, A
1995-09-01
There is increasing awareness of the needs of children with low vision, particularly in developing countries where programmes of integrated education are being developed. However, appropriate low vision services are usually not available or affordable. The aims of this study were, firstly, to assess the need for spectacles and optical low vision devices in students with low vision in schools for the blind in Kenya and Uganda; secondly, to evaluate inexpensive locally produced low vision devices; and, finally, to evaluate simple methods of identifying those low vision students who could read N5 to N8 print after low vision assessment. A total of 230 students were examined (51 school and 16 university students in Uganda and 163 students in Kenya, aged 5-22 years), 147 of whom had a visual acuity of less than 6/18 to perception of light in the better eye at presentation. After refraction seven of the 147 achieved 6/18 or better. Eighty two (58.6%) of the 140 students with low vision (corrected visual acuity in the better eye of less than 6/18 to light perception) had refractive errors of more than 2 dioptres in the better eye, and 38 (27.1%) had more than 2 dioptres of astigmatism. Forty six per cent of students with low vision (n = 64) could read N5-N8 print unaided or with spectacles, as could a further 33% (n = 46) with low vision devices. Low vision devices were indicated in a total of 50 students (35.7%). The locally manufactured devices could meet two thirds of the need. A corrected distance acuity of 1/60 or better had a sensitivity of 99.1% and a specificity of 56.7% in predicting the ability to discern N8 print or better. The ability to perform at least two of the three simple tests of functional vision had a sensitivity of 95.5% and a specificity of 63.3% in identifying the students able to discern N8 or better.
A computer vision system for the recognition of trees in aerial photographs
NASA Technical Reports Server (NTRS)
Pinz, Axel J.
1991-01-01
Increasing problems of forest damage in Central Europe set the demand for an appropriate forest damage assessment tool. The Vision Expert System (VES) is presented which is capable of finding trees in color infrared aerial photographs. Concept and architecture of VES are discussed briefly. The system is applied to a multisource test data set. The processing of this multisource data set leads to a multiple interpretation result for one scene. An integration of these results will provide a better scene description by the vision system. This is achieved by an implementation of Steven's correlation algorithm.
Colour vision experimental studies in teaching of optometry
NASA Astrophysics Data System (ADS)
Ozolinsh, Maris; Ikaunieks, Gatis; Fomins, Sergejs
2005-10-01
Following aspects related to human colour vision are included in experimental lessons for optometry students of University of Latvia. Characteristics of coloured stimuli (emitting and reflective), determination their coordinates in different colour spaces. Objective characteristics of transmitting of colour stimuli through the optical system of eye together with various types of appliances (lenses, prisms, Fresnel prisms). Psychophysical determination of mono- and polychromatic stimuli perception taking into account physiology of eye, retinal colour photoreceptor topography and spectral sensitivity, spatial and temporal characteristics of retinal receptive fields. Ergonomics of visual perception, influence of illumination and glare effects, testing of colour vision deficiencies.
Vision rehabilitation interventions following mild traumatic brain injury: a scoping review.
Simpson-Jones, Mary E; Hunt, Anne W
2018-04-10
To broadly examine the literature to identify vision interventions following mild traumatic brain injury. Objectives are to identify: (1) evidence-informed interventions for individuals with visual dysfunction after mild traumatic brain injury; (2) professions providing these interventions; (3) gaps in the literature and areas for further research. A scoping review was conducted of four electronic databases of peer-reviewed literature from the databases earliest records to June 2017. Articles were included if the study population was mild traumatic brain injury/concussion and a vision rehabilitation intervention was tested. Two independent reviewers screened articles for inclusion, extracted data, and identified themes. The initial search identified 3111 records. Following exclusions, 22 articles were included in the final review. Nine studies evaluated optical devices, such as corrective spectacles, contact lenses, prisms, or binasal occlusion. Two studies assessed vision therapy. Ten studies examined vision therapy using optical devices. One study investigated hyperbaric oxygen therapy. Optometrists performed these interventions in most of the studies. Future research should address quality appraisal of this literature, interventions that include older adult and pediatric populations, and interdisciplinary interventions. There are promising interventions for vision deficits following mild traumatic brain injury. However, there are multiple gaps in the literature that should be addressed by future research. Implications for Rehabilitation Mild traumatic brain injury may result in visual deficits that can contribute to poor concentration, headaches, fatigue, problems reading, difficulties engaging in meaningful daily activities, and overall reduced quality of life. Promising interventions for vision rehabilitation following mild traumatic brain injury include the use of optical devices (e.g., prism glasses), vision or oculomotor therapy (e.g., targeted exercises to train eye movements), and a combination of optical devices and vision therapy. Rehabilitation Professionals (e.g., optometrists, occupational therapists, physiotherapists) have an important role in screening for vision impairments, recommending referrals appropriately to vision specialists, and/or assessing and treating functional vision deficits in individuals with mild traumatic brain injury.
Evaluation of the attentional capacities and working memory of early and late blind persons.
Pigeon, Caroline; Marin-Lamellet, Claude
2015-02-01
Although attentional processes and working memory seem to be significantly involved in the daily activities (particularly during navigating) of persons who are blind and who use these abilities to compensate for their lack of vision, few studies have investigated these mechanisms in this population. The aim of this study is to evaluate the selective, sustained and divided attention, attentional inhibition and switching and working memory of blind persons. Early blind, late blind and sighted participants completed neuropsychological tests that were designed or adapted to be achievable in the absence of vision. The results revealed that the early blind participants outperformed the sighted ones in selective, sustained and divided attention and working memory tests, and the late blind participants outperformed the sighted participants in selective, sustained and divided attention. However, no differences were found between the blind groups and the sighted group in the attentional inhibition and switching tests. Furthermore, no differences were found between the early and late blind participants in this set of tests. These results suggest that early and late blind persons can compensate for the lack of vision by an enhancement of the attentional and working memory capacities. Copyright © 2014 Elsevier B.V. All rights reserved.
[Quantitative Color Vision Defect Evaluation - Lanthony Test and its Modified Interpretation].
Veselý, P; Urbánek, D; Synek, S; Hanák, L
2016-01-01
Our aim was to develop quick and exact instrument for examination of color vision defects (CVD). We used Lanthony saturated and desaturated test. Data were evaluated according the Vingrys and King-Smith study. We had together 123 eyes of 86 patients. From all subjects we received these average values: AA 44.32 (min -87.13, max 80.64), TES 13.36 (min 8.84, max 30.30), SI 1.97 (min 1.22, max 5.69) and CI 1.66 (min 1.0, max 3.94). At the base of counting algorithm and average values form saturated and desaturated test we revealed 25 (29 %) patients with CVD. Twelve patients (14 %) classified as CVD+ had dichromacy and all had inborn CVD. Eight patients (9 %) from this group had deutranopia and four patient (5 %) protanopia. Anomaly trichromacy we revealed in thirteen patients (15 %). Eight (9 %) of these patients had inborn CVD. Six (7 %) of these patients had protanomalia, one (1 %) had deuteranomalia and one tritanomalia. We established and specified TES, CI and SI critical values, which was used to dividing patients into specific groups. Lanthony test, color vision defect, index of selectivity, index of confusion, total error score.
Lee, Eun-Hee; Paek, Domyung; Kho, Young Lim; Choi, Kyungho; Chae, Hong Jae
2013-01-01
We evaluated color vision impairment in workers exposed to organic solvents, especially xylene. Three groups of subjects, comprising 63 workers occupationally exposed to organic solvents, 122 non-exposed workers in the same industry, and 185 subjects from the general population as controls, were evaluated for color vision. Exposure to solvents was indirectly evaluated by measuring the concentration of a urinary metabolite. Color vision was assessed using the Lanthony Desaturated 15-hue (Lanthony D-15) panel. Color confusion index (CCI) values in the exposed group were significantly higher than in the non-exposed workers or the general population, after adjustment for age and education, and significantly correlated with the concentration of methylhippuric acid. Color vision impairments were detected more frequently among the exposed group, and the most common types were type III and complex impairments. The rate of type III impairments was 9.52% in the exposed group, 1.64% in the non-exposed group, and 1.62% in the general population. Our results support the hypothesis that acquired color vision impairments could be induced by exposure to xylene. Testing for color vision impairment is a relatively simple, non-invasive and sensitive diagnostic method for relatively low-level exposures to xylene. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Niemi, Paul R.; D., O.; Mc Leod, David M.; Mc Leod, Roger D.
2007-04-01
RDM taught a health professional how to recover her previously impaired near vision in one session, also bringing a similar male from 20/30 to 20/10, distance vision, in about ten minutes; another health professional's improvement went from 20/300 to 20/20 in three sessions. A former athlete achieved a distance improvement from 20/800 to 20/100, again, in three sessions. RDM offers to replicate these types of improvements, using patent-pending Naturoptics under monitored conditions, and non-disclosure restraints, to protect franchising and patent-pending rights. Evening atropine use, controlled, at Singapore's National Eye Center, demonstrated an effect against myopia. Does this actually constitute an experimental verification of Mc Leod's Airy-disk radius-formula explanation of how vision works, and predicts how it can be damaged/repaired? Evaluation and documentation is to be by close and distance vision standard charts, or their equivalents, with guaranteed ``chart'' improvements of one line per session, after the beginning visit, or the session is free. Patent-pending Naturoptics differs from all vision-boosting competitors by safely re-eliciting vision's feedback control self-repairs, including astigmatism and presbyopia. To cite this abstract, use the following reference: http://meetings.aps.org/link/BAPS.2007.NES07.C2.4
[Web-based analysis of Stilling's color plates].
Kuchenbecker, J
2014-12-01
Color vision tests with pseudoisochromatic plates currently represent the most common procedure for the screening of congenital color vision deficiencies. By means of a web-based color vision test, new and old color plates can be tested for diagnostic quality without major effort. A total of 16 digitized Stilling's color plates of the 11th edition from 1907 were included in a web-based color vision test (http://www.farbsehtest.de). The χ(2)-test was used to check whether the Stilling color plates showed similar results to the nine previously evaluated Ishihara color plates. A total of 518 subjects including101 (19.5 %) female subjects with a mean age of 34.6 ± 17 years, took the web-based test with the 25 plates. For all participants the range for the correctly recognized plates was between 5.2 % (n = 27) and 97.7 % (n = 506) for the Stilling color plates and between 64.9 % (n = 336) and 100 % (n = 518) for the Ishihara color plates. For participants with more than 5 errors (n = 247), the range for correctly recognized plates was between 2.0 % (n = 5) and 98.0 % (n = 242) for the Stilling plates and between 42.5 % (n = 105) and 100 % (n = 247) for the Ishihara plates. Taking all color plates and all participants into account there was a significantly higher incidence of erroneous recognition of the Stilling color plates (3038 false and 5250 true answers) compared to the Ishihara color plates (1511 false and 3151 true answers) (p < 0.001, χ(2)-test). The diagnostic quality of the tested Stilling color pates was very variable. Some of the plates could be used for the test edition of the Velhagen/Broschmann/Kuchenbecker color plates from 2014. Overall, the Stilling color plates were recognized with a higher incidence of error by all participants in the web-based test compared to the utilized Ishihara color plates, which in most cases was attributable to ambiguity of some symbols.
[Personnel with poor vision at fighter pilot school].
Corbé, C; Menu, J P
1997-10-01
The piloting of fighting aircraft, the navigation of space-shuttle, the piloting of an helicopter in tactical flight at an altitude of 50 metres require the use of all sensorial, ocular, vestibular, proprioceptive ... sensors. So, the selection and the follow-up of these aerial engines' pilots need a very complete study of medical parameters, in particular sensorial and notably visual system. The doctors and the expert researchers in Aeronautical and spatial Medicine of the Army Health Department, which have in charge the medical supervision of flight crew, should study, create, and improve tests of visual sensorial exploration developed from fundamental and applied research. These authenticated tests with military pilots were applied in ophthalmology for the estimation of normal and deficient vision. A proposition to change norms of World Health Organisation applied to the vision has been following these to low visual persons was equally introduced.
Use of a vision model to quantify the significance of factors effecting target conspicuity
NASA Astrophysics Data System (ADS)
Gilmore, M. A.; Jones, C. K.; Haynes, A. W.; Tolhurst, D. J.; To, M.; Troscianko, T.; Lovell, P. G.; Parraga, C. A.; Pickavance, K.
2006-05-01
When designing camouflage it is important to understand how the human visual system processes the information to discriminate the target from the background scene. A vision model has been developed to compare two images and detect differences in local contrast in each spatial frequency channel. Observer experiments are being undertaken to validate this vision model so that the model can be used to quantify the relative significance of different factors affecting target conspicuity. Synthetic imagery can be used to design improved camouflage systems. The vision model is being used to compare different synthetic images to understand what features in the image are important to reproduce accurately and to identify the optimum way to render synthetic imagery for camouflage effectiveness assessment. This paper will describe the vision model and summarise the results obtained from the initial validation tests. The paper will also show how the model is being used to compare different synthetic images and discuss future work plans.
Ma, Jun; Lewis, Megan A; Smyth, Joshua M
2018-04-12
In this commentary, we propose a vision for "practice-based translational behavior change research," which we define as clinical and public health practice-embedded research on the implementation, optimization, and fundamental mechanisms of behavioral interventions. This vision intends to be inclusive of important research elements for behavioral intervention development, testing, and implementation. We discuss important research gaps and conceptual and methodological advances in three key areas along the discovery (development) to delivery (implementation) continuum of evidence-based interventions to improve behavior and health that could help achieve our vision of practice-based translational behavior change research. We expect our proposed vision to be refined and evolve over time. Through highlighting critical gaps that can be addressed by integrating modern theoretical and methodological approaches across disciplines in behavioral medicine, we hope to inspire the development and funding of innovative research on more potent and implementable behavior change interventions for optimal population and individual health.
External Vision Systems (XVS) Proof-of-Concept Flight Test Evaluation
NASA Technical Reports Server (NTRS)
Shelton, Kevin J.; Williams, Steven P.; Kramer, Lynda J.; Arthur, Jarvis J.; Prinzel, Lawrence, III; Bailey, Randall E.
2014-01-01
NASA's Fundamental Aeronautics Program, High Speed Project is performing research, development, test and evaluation of flight deck and related technologies to support future low-boom, supersonic configurations (without forward-facing windows) by use of an eXternal Vision System (XVS). The challenge of XVS is to determine a combination of sensor and display technologies which can provide an equivalent level of safety and performance to that provided by forward-facing windows in today's aircraft. This flight test was conducted with the goal of obtaining performance data on see-and-avoid and see-to-follow traffic using a proof-of-concept XVS design in actual flight conditions. Six data collection flights were flown in four traffic scenarios against two different sized participating traffic aircraft. This test utilized a 3x1 array of High Definition (HD) cameras, with a fixed forward field-of-view, mounted on NASA Langley's UC-12 test aircraft. Test scenarios, with participating NASA aircraft serving as traffic, were presented to two evaluation pilots per flight - one using the proof-of-concept (POC) XVS and the other looking out the forward windows. The camera images were presented on the XVS display in the aft cabin with Head-Up Display (HUD)-like flight symbology overlaying the real-time imagery. The test generated XVS performance data, including comparisons to natural vision, and post-run subjective acceptability data were also collected. This paper discusses the flight test activities, its operational challenges, and summarizes the findings to date.
2009-03-01
infrared, thermal , or night vision applications. Understanding the true capabilities and limitations of the ALAN camera and its applicability to a...an option to more expensive infrared, thermal , or night vision applications. Ultimately, it will be clear whether the configuration of the Kestrel...45 A. THERMAL CAMERAS................................................................................45 1
NASA Technical Reports Server (NTRS)
2008-01-01
The Bird Vision system is a multicamera photogrammerty software application that runs on a Microsoft Windows XP platform and was developed at Kennedy Space Center by ASRC Aerospace. This software system collects data about the locations of birds within a volume centered on the Space Shuttle and transmits it in real time to the laptop computer of a test director in the Launch Control Center (LCC) Firing Room.
Honeine, Jean-Louis; Crisafulli, Oscar; Schieppati, Marco
2017-02-01
The aim of this study was to test the effects of a concurrent cognitive task on the promptness of the sensorimotor integration and reweighting processes following addition and withdrawal of vision. Fourteen subjects stood in tandem while vision was passively added and removed. Subjects performed a cognitive task, consisting of counting backward in steps of three, or were "mentally idle." We estimated the time intervals following addition and withdrawal of vision at which body sway began to change. We also estimated the time constant of the exponential change in body oscillation until the new level of sway was reached, consistent with the current visual state. Under the mentally idle condition, mean latency was 0.67 and 0.46 s and the mean time constant was 1.27 and 0.59 s for vision addition and withdrawal, respectively. Following addition of vision, counting backward delayed the latency by about 300 ms, without affecting the time constant. Following withdrawal, counting backward had no significant effect on either latency or time constant. The extension by counting backward of the time interval to stabilization onset on addition of vision suggests a competition for allocation of cortical resources. Conversely, the absence of cognitive task effect on the rapid onset of destabilization on vision withdrawal, and on the relevant reweighting time course, advocates the intervention of a subcortical process. Diverting attention from a challenging standing task discloses a cortical supervision on the process of sensorimotor integration of new balance-stabilizing information. A subcortical process would instead organize the response to removal of the stabilizing sensory input. NEW & NOTEWORTHY This study is the first to test the effect of an arithmetic task on the time course of balance readjustment following visual withdrawal or addition. Performing such a cognitive task increases the time delay following addition of vision but has no effect on withdrawal dynamics. This suggests that sensorimotor integration following addition of a stabilizing signal is performed at a cortical level, whereas the response to its withdrawal is "automatic" and accomplished at a subcortical level. Copyright © 2017 the American Physiological Society.
A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.
Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G
2015-02-01
Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. Laser scanning was accomplished with a dual control strategy, which adds a vision-based trajectory correction phase to a fast open-loop laser controller. The system is designed to eliminate open-loop aiming errors caused by system calibration limitations and by the unpredictable topology of real targets. Evaluation of the new system was performed using CO(2) laser cutting trials on artificial targets and ex-vivo tissue. This system produced accuracy values corresponding to pixel resolution even when smoke created by the laser-target interaction clutters the camera view. In realistic test scenarios, trajectory following RMS errors were reduced by almost 80 % with respect to open-loop system performances, reaching mean error values around 30 μ m and maximum observed errors in the order of 60 μ m. A new vision-based laser microsurgical control system was shown to be effective and promising with significant positive potential impact on the safety and quality of laser microsurgeries.
Kim, Min Young; Lee, Hyunkee; Cho, Hyungsuck
2008-04-10
One major research issue associated with 3D perception by robotic systems is the creation of efficient sensor systems that can generate dense range maps reliably. A visual sensor system for robotic applications is developed that is inherently equipped with two types of sensor, an active trinocular vision and a passive stereo vision. Unlike in conventional active vision systems that use a large number of images with variations of projected patterns for dense range map acquisition or from conventional passive vision systems that work well on specific environments with sufficient feature information, a cooperative bidirectional sensor fusion method for this visual sensor system enables us to acquire a reliable dense range map using active and passive information simultaneously. The fusion algorithms are composed of two parts, one in which the passive stereo vision helps active vision and the other in which the active trinocular vision helps the passive one. The first part matches the laser patterns in stereo laser images with the help of intensity images; the second part utilizes an information fusion technique using the dynamic programming method in which image regions between laser patterns are matched pixel-by-pixel with help of the fusion results obtained in the first part. To determine how the proposed sensor system and fusion algorithms can work in real applications, the sensor system is implemented on a robotic system, and the proposed algorithms are applied. A series of experimental tests is performed for a variety of configurations of robot and environments. The performance of the sensor system is discussed in detail.
Vision-based body tracking: turning Kinect into a clinical tool.
Morrison, Cecily; Culmer, Peter; Mentis, Helena; Pincus, Tamar
2016-08-01
Vision-based body tracking technologies, originally developed for the consumer gaming market, are being repurposed to form the core of a range of innovative healthcare applications in the clinical assessment and rehabilitation of movement ability. Vision-based body tracking has substantial potential, but there are technical limitations. We use our "stories from the field" to articulate the challenges and offer examples of how these can be overcome. We illustrate that: (i) substantial effort is needed to determine the measures and feedback vision-based body tracking should provide, accounting for the practicalities of the technology (e.g. range) as well as new environments (e.g. home). (ii) Practical considerations are important when planning data capture so that data is analysable, whether finding ways to support a patient or ensuring everyone does the exercise in the same manner. (iii) Home is a place of opportunity for vision-based body tracking, but what we do now in the clinic (e.g. balance tests) or in the home (e.g. play games) will require modifications to achieve capturable, clinically relevant measures. This article articulates how vision-based body tracking works and when it does not to continue to inspire our clinical colleagues to imagine new applications. Implications for Rehabilitation Vision-based body tracking has quickly been repurposed to form the core of innovative healthcare applications in clinical assessment and rehabilitation, but there are clinical as well as practical challenges to make such systems a reality. Substantial effort needs to go into determining what types of measures and feedback vision-based body tracking should provide. This needs to account for the practicalities of the technology (e.g. range) as well as the opportunities of new environments (e.g. the home). Practical considerations need to be accounted for when planning capture in a particular environment so that data is analysable, whether it be finding a chair substitute, ways to support a patient or ensuring everyone does the exercise in the same manner. The home is a place of opportunity with vision-based body tracking, but it would be naïve to think that we can do what we do now in the clinic (e.g. balance tests) or in the home (e.g. play games), without appropriate modifications to what constitutes a practically capturable, clinically relevant measure.
Performance of the Spot Vision Screener in Children Younger Than 3 Years of Age.
Forcina, Blake D; Peterseim, M Millicent; Wilson, M Edward; Cheeseman, Edward W; Feldman, Samuel; Marzolf, Amanda L; Wolf, Bethany J; Trivedi, Rupal H
2017-06-01
To evaluate the use of the Spot Vision Screener (Spot; Welch Allyn, Skaneateles Falls, New York, USA) for detection of amblyopia risk factors in children aged 6 months to 3 years, as defined by the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus. Reliability analysis. In this study, children seen from June 1, 2012, to April 30, 2016 were tested with the Spot during a routine visit. Enrolled children underwent a comprehensive eye examination including cycloplegic refraction and sensorimotor testing within 6 months of the testing date by a pediatric ophthalmologist masked to the Spot results. A total of 184 children were included. The Spot successfully obtained readings in 89.7% of patients. Compared with the ophthalmologist's examination, the Spot had an overall sensitivity of 89.8% and a specificity of 70.4%. The Spot achieved good sensitivity and specificity for detection of amblyopia risk factors in this young cohort, particularly in the older subgroup. Our data offer support for automated vision screening in young children. Copyright © 2017 Elsevier Inc. All rights reserved.
A computer-controlled color vision test for children based on the Cambridge Colour Test.
Goulart, Paulo R K; Bandeira, Marcio L; Tsubota, Daniela; Oiwa, Nestor N; Costa, Marcelo F; Ventura, Dora F
2008-01-01
The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees of visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment 1 sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects' performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data--including those obtained for children--fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.
Huna-Baron, Ruth; Glovinsky, Yoseph; Habot-Wilner, Zohar
2013-02-01
The aim of this work was to compare the specificity-sensitivity balance of the Hardy-Rand-Rittler (HRR) 4th edition with the Ishihara color plate tests for color-vision defects in patients with optic neuropathy. This is a prospective case-control study. The study group included 43 patients (48 eyes) with newly diagnosed optic neuropathy, and the control group included 33 patients (33 right eyes) who were referred to the eye clinic for conditions other than optic nerve or retinal macular disorders. Individuals with visual acuity of less than 20/70 (0.54 Log MAR) were excluded. All patients underwent comprehensive eye examination and color-vision evaluation with both tests in a random order under standardized lighting conditions. The scores of the Ishihara and HRR tests were set as the number of plates identified out of 12 and six respectively. The receiver operating characteristics (ROC) curve was statistically significantly better when using the HRR test (area under curve [AUC] = 0.93 ± 0.03) than for the Ishihara test (AUC = 0.77 ± 0.05) (P = 0.0006). The best specificity-sensitivity balance for the HRR was 100 % and 79 % respectively, and for the Ishihara test 100 % and 48 % respectively. The HRR 4th edition test proved to be superior to the Ishihara test in detecting acquired dyschromatopsia due to optic neuropathy. We recommend using the HRR 4th edition test as a screening method for detection of color-vision defects in patients with optic neuropathy.
The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.
Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar
2018-03-01
This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility (< 10 cycles per minute), and the difference between near and distance phoria (> 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near phoria, and monocular accommodative facility yield good sensitivity and specificity for diagnosis of NSBVAs in a community set-up. © 2017 Optometry Australia.
Multiparameter vision testing apparatus
NASA Technical Reports Server (NTRS)
Hunt, S. R., Jr.; Homkes, R. J.; Poteate, W. B.; Sturgis, A. C. (Inventor)
1975-01-01
Compact vision testing apparatus is described for testing a large number of physiological characteristics of the eyes and visual system of a human subject. The head of the subject is inserted into a viewing port at one end of a light-tight housing containing various optical assemblies. Visual acuity and other refractive characteristics and ocular muscle balance characteristics of the eyes of the subject are tested by means of a retractable phoroptor assembly carried near the viewing port and a film cassette unit carried in the rearward portion of the housing (the latter selectively providing a variety of different visual targets which are viewed through the optical system of the phoroptor assembly). The visual dark adaptation characteristics and absolute brightness threshold of the subject are tested by means of a projector assembly which selectively projects one or both of a variable intensity fixation target and a variable intensity adaptation test field onto a viewing screen located near the top of the housing.
Zhang, Dashan; Guo, Jie; Lei, Xiujun; Zhu, Changan
2016-04-22
The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD) sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.
Role of high-order aberrations in senescent changes in spatial vision
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliot, S; Choi, S S; Doble, N
2009-01-06
The contributions of optical and neural factors to age-related losses in spatial vision are not fully understood. We used closed-loop adaptive optics to test the visual benefit of correcting monochromatic high-order aberrations (HOAs) on spatial vision for observers ranging in age from 18-81 years. Contrast sensitivity was measured monocularly using a two-alternative forced choice (2AFC) procedure for sinusoidal gratings over 6 mm and 3 mm pupil diameters. Visual acuity was measured using a spatial 4AFC procedure. Over a 6 mm pupil, young observers showed a large benefit of AO at high spatial frequencies, whereas older observers exhibited the greatest benefitmore » at middle spatial frequencies, plus a significantly larger increase in visual acuity. When age-related miosis is controlled, young and old observers exhibited a similar benefit of AO for spatial vision. An increase in HOAs cannot account for the complete senescent decline in spatial vision. These results may indicate a larger role of additional optical factors when the impact of HOAs is removed, but also lend support for the importance of neural factors in age-related changes in spatial vision.« less
Aslan, Ummuhan Bas; Calik, Bilge Basakcı; Kitiş, Ali
2012-01-01
This study was planned in order to determine physical activity levels of visually impaired children and adolescents and to investigate the effect of gender and level of vision on physical activity level in visually impaired children and adolescents. A total of 30 visually impaired children and adolescents (16 low vision and 14 blind) aged between 8 and 16 years participated in the study. The physical activity level of cases was evaluated with a physical activity diary (PAD) and one-mile run/walk test (OMR-WT). No difference was found between the PAD and the OMR-WT results of low vision and blind children and adolescents. The visually impaired children and adolescents were detected not to participate in vigorous physical activity. A difference was found in favor of low vision boys in terms of mild, moderate activities and OMR-WT durations. However, no difference was found between physical activity levels of blind girls and boys. The results of our study suggested that the physical activity level of visually impaired children and adolescents was low, and gender affected physical activity in low vision children and adolescents. Copyright © 2012 Elsevier Ltd. All rights reserved.
Paudel, Prakash; Kovai, Vilas; Naduvilath, Thomas; Phuong, Ha Thanh; Ho, Suit May; Giap, Nguyen Viet
2016-01-01
To assess validity of teacher-based vision screening and elicit factors associated with accuracy of vision screening in Vietnam. After brief training, teachers independently measured visual acuity (VA) in 555 children aged 12-15 years in Ba Ria - Vung Tau Province. Teacher VA measurements were compared to those of refractionists. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for uncorrected VA (UVA) and presenting VA (PVA) 20/40 or worse in either eye. Chi-square, Fisher's exact test and multivariate logistic regression were used to assess factors associated with accuracy of vision screening. Level of significance was set at 5%. Trained teachers in Vietnam demonstrated 86.7% sensitivity, 95.7% specificity, 86.7% positive predictive value and 95.7% negative predictive value in identifying children with visual impairment using the UVA measurement. PVA measurement revealed low accuracy for teachers, which was significantly associated with child's age, sex, spectacle wear and myopic status, but UVA measurement showed no such associations. Better accuracy was achieved in measurement of VA and identification of children with visual impairment using UVA measurement compared to PVA. UVA measurement is recommended for teacher-based vision screening programs.
... shade or curtain hanging across part of your visual field. Optic neuritis : inflammation of the optic nerve ... to ask your doctor Images Crossed eyes Eye Visual acuity test Slit-lamp exam Visual field test ...
Pseudoisochromatic test plate colour representation dependence on printing technology
NASA Astrophysics Data System (ADS)
Luse, K.; Fomins, S.; Ozolinsh, M.
2012-08-01
The aim of the study is to determine best printing technology for creation of colour vision deficiency tests. Valid tests for protanopia and deuteranopia were created from perceived colour matching experiments from printed colour samples by colour deficient individuals. Calibrated EpsonStylus Pro 7800 printer for ink prints and Noritsu HD 3701 digital printer for photographic prints were used. Multispectral imagery (by tunable liquid crystal filters system CRI Nuance Vis 07) data analysis show that in case of ink prints, the measured pixel colour coordinate dispersion (in the CIExy colour diagram) of similar colour arrays is smaller than in case of photographic printing. The print quality in terms of colour coordinate dispersion for printing methods used is much higher than in case of commercially available colour vision deficiency tests.
An assembly system based on industrial robot with binocular stereo vision
NASA Astrophysics Data System (ADS)
Tang, Hong; Xiao, Nanfeng
2017-01-01
This paper proposes an electronic part and component assembly system based on an industrial robot with binocular stereo vision. Firstly, binocular stereo vision with a visual attention mechanism model is used to get quickly the image regions which contain the electronic parts and components. Secondly, a deep neural network is adopted to recognize the features of the electronic parts and components. Thirdly, in order to control the end-effector of the industrial robot to grasp the electronic parts and components, a genetic algorithm (GA) is proposed to compute the transition matrix and the inverse kinematics of the industrial robot (end-effector), which plays a key role in bridging the binocular stereo vision and the industrial robot. Finally, the proposed assembly system is tested in LED component assembly experiments, and the results denote that it has high efficiency and good applicability.
Visual training improves underwater vision in children.
Gislén, Anna; Warrant, Eric J; Dacke, Marie; Kröger, Ronald H H
2006-10-01
Children in a tribe of sea-gypsies from South-East Asia have been found to have superior underwater vision compared to European children. In this study, we show that the improved underwater vision of these Moken children is not due to better contrast sensitivity in general. We also show that European children can achieve the same underwater acuity as the Moken children. After 1 month of underwater training (11 sessions) followed by 4 months with no underwater activities, European children showed improved underwater vision and distinct bursts of pupil constriction. When tested 8 months after the last training session in an outdoor pool in bright sunlight-comparable to light environments in South-East Asia-the children had attained the same underwater acuity as the sea-gypsy children. The achieved performance can be explained by the combined effect of pupil constriction and strong accommodation.
FLORA™: Phase I development of a functional vision assessment for prosthetic vision users.
Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy
2015-07-01
Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population to evaluate the impact of new vision-restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional visual ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional visual tasks for observation of performance and a case narrative summary. Results were analysed to determine whether the interview questions and functional visual tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, 26 subjects were assessed with the FLORA. Seven different evaluators administered the assessment. All 14 interview questions were asked. All 35 tasks for functional vision were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options—impossible (33 per cent), difficult (23 per cent), moderate (24 per cent) and easy (19 per cent)—were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with 'vision only' occurring 75 per cent on average with the System ON, and 29 per cent with the System OFF. The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as an assessment tool for functional vision and well-being. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.
Reduced vision in highly myopic eyes without ocular pathology: the ZOC-BHVI high myopia study.
Jong, Monica; Sankaridurg, Padmaja; Li, Wayne; Resnikoff, Serge; Naidoo, Kovin; He, Mingguang
2018-01-01
The aim was to investigate the relationship of the magnitude of myopia with visual acuity in highly myopic eyes without ocular pathology. Twelve hundred and ninety-two highly myopic eyes (up to -6.00 DS both eyes, no astigmatic cut-off) with no ocular pathology from the ZOC-BHVI high myopia study in China, had cycloplegic refraction, followed by subjective refraction and visual acuities and axial length measurement. Two logistic regression models were undertaken to test the association of age, gender, refractive error, axial length and parental myopia with reduced vision. Mean group age was 19.0 ± 8.6 years; subjective spherical equivalent refractive error was -9.03 ± 2.73 D; objective spherical equivalent refractive error was -8.90 ± 2.60 D and axial length was 27.0 ± 1.3 mm. Using visual acuity, 82.4 per cent had normal vision, 16.0 per cent had mildly reduced vision, 1.2 per cent had moderately reduced vision, 0.3 per cent had severely reduced vision and no subjects were blind. The percentage with reduced vision increased with spherical equivalent to 74.5 per cent from -15.00 to -39.99 D, axial length to 67.7 per cent of eyes from 30.01 to 32.00 mm and age to 22.9 per cent of those 41 years and over. Spherical equivalent and axial length were significantly associated with reduced vision (p < 0.0001). Age and parental myopia were not significantly associated with reduced vision. Gender was significant for one model (p = 0.04). Mildly reduced vision is common in high myopia without ocular pathology and is strongly correlated with greater magnitudes of refractive error and axial length. Better understanding is required to minimise reduced vision in high myopes. © 2017 Optometry Australia.
OCULAR SYPHILIS IN A KIDNEY TRANSPLANT RECIPIENT
ROMAO, Elen A.; BOLELLA, Valdes R.; NARDIN, Maria Estela P.; HABIB-SIMAO, Maria Lucia; FURTADO, João Marcelo; MOYSES-NETO, Miguel
2016-01-01
We present a case of ocular syphilis after a renal transplantation involving progressive vision loss without clinically identifiable ocular disease. Electroretinography showed signs of ischemia, especially in the internal retina. A serological test was positive for syphilis. Lumbar puncture revealed lymphocytic meningitis and a positive serologic test for syphilis in the cerebrospinal fluid. The patient was treated with penicillin, and had a quick vision improvement. In the case of transplant recipients, clinicians should always consider the diagnosis of ocular syphilis in cases with unexplained visual acuity decrement, as this condition may cause serious complications if not treated. PMID:27253748
A rotorcraft flight database for validation of vision-based ranging algorithms
NASA Technical Reports Server (NTRS)
Smith, Phillip N.
1992-01-01
A helicopter flight test experiment was conducted at the NASA Ames Research Center to obtain a database consisting of video imagery and accurate measurements of camera motion, camera calibration parameters, and true range information. The database was developed to allow verification of monocular passive range estimation algorithms for use in the autonomous navigation of rotorcraft during low altitude flight. The helicopter flight experiment is briefly described. Four data sets representative of the different helicopter maneuvers and the visual scenery encountered during the flight test are presented. These data sets will be made available to researchers in the computer vision community.
New Method of Screening Young Children for Defects in Visual Acuity*
Withnell, Allan; Wilson, H. E.
1968-01-01
The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed. PMID:5681052
New method of screening young children for defects in visual acuity.
Withnell, A; Wilson, H E
1968-10-19
The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed.
The impact of loupes and microscopes on vision in endodontics.
Perrin, P; Neuhaus, K W; Lussi, A
2014-05-01
To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Capruso, Daniel X; Hamsher, Kerry deS
2011-06-01
Clinical evaluation and research on constructional ability have come to rely almost exclusively on two-dimensional tasks such as graphomotor copying or mosaic Block Design (BD). A return to the inclusion of a third dimension in constructional tests may increase the spatial demands of the task, and improve understanding of the relationship between visual perception and constructional ability in patients with cerebral disease. Subjects were patients (n=43) with focal or multifocal cerebrovascular lesions as determined by CT or MRI. Tests of temporal orientation, verbal intelligence, language, object vision and spatial vision were used to determine which factors were predictive of performance on two-dimensional BD and Three-Dimensional Block Construction (3-DBC) tasks. Stepwise linear regression indicated that spatial vision predicted BD performance, and was even more strongly predictive of 3-DBC. Other cognitive domains did not account for significant additional variance in performance of either BD or 3-DBC. Bilateral cerebral lesions produced more severe deficits on BD than did unilateral cerebral lesions. The presence of a posterior cerebral lesion was the significant factor in producing deficits in 3-DBC. The spatial aspect of a constructional task is enhanced when the patient is required to assemble an object in all three dimensions of space. In the typical patient with cerebrovascular disease, constructional deficits typically occur in the context of a wider syndrome of deficits in spatial vision. Copyright © 2010 Elsevier Srl. All rights reserved.
Colour vision and contrast sensitivity losses of mercury intoxicated industry workers in Brazil.
Ventura, D F; Simões, A L; Tomaz, S; Costa, M F; Lago, M; Costa, M T V; Canto-Pereira, L H M; de Souza, J M; Faria, M A M; Silveira, L C L
2005-05-01
We evaluated vision loss in workers from fluorescent lamp industries (n=39) who had retired due to intoxication with mercury vapour and had been away from the work situation for several years (mean=6.32 years). An age-matched control group was submitted to the same tests for comparison. The luminance contrast sensitivity (CSF) was measured psychophysically and with the sweep visual evoked potential (sVEP) method. Chromatic red-green and blue-yellow CSFs were measured psychophysically. Colour discrimination was assessed with the Farnsworth-Munsell 100-hue test, Lanthony D-15d test and Cambridge Colour Vision Test. Patient data showed significantly lower scores in all colour tests compared to controls (p<.001). The behavioural luminance CSF of the patients was lower than that of controls (p<.001 at all frequencies tested). This result was confirmed by the electrophysiologically measured sweep VEP luminance CSF except at the highest frequencies-a difference that might be related to stimulus differences in the two situations. Chromatic CSFs were also statistically significantly lower for the patients than for the controls, for both chromatic equiluminant stimuli: red-green (p<.005) and blue-yellow (p<.04 for all frequencies, except 2 cycles per degree (cpd), the highest spatial frequency tested) spatial gratings. We conclude that exposure to elemental mercury vapour is associated with profound and lasting losses in achromatic and chromatic visual functions, affecting the magno-, parvo- and koniocellular visual pathways.
Procedures for Testing Color Vision,
1981-01-01
Chromatic Discriminative Ability, 8 Congenital Sex-Linked Color Vision Defects, 8 Anomalous Trichromats, 9 Dichromats, 10 Autosomal Dominant Tritan Defect...anomalous trichromats (see Chapter 3). AUTOSOMAL DOMINANT TRITAN DEFECT In addition to the X-chromosomal-linked color defects, there are some very rare... hereditary color defects. The tritan defect is one of these rare defects (minimum frequency estimated to be between 1/13,000 and 1/65,000 [Kalmus
ERIC Educational Resources Information Center
Brunner, Ilse; And Others
Organizations are the product of the ideas and interactions of those who work in them. The challenge for learning in organizations is to have a shared purpose and vision of the organization, to develop new ideas arising out of the vision and purpose, to test the ideas in the organizational reality, and to communicate that knowledge to other…
Suprathreshold Contrast Sensitivity Vision Test Chart
1991-07-14
with data collected on patients having amblyopia , glaucoma and macular degeneration showed that the SCTS may be effectively used as an initial...dramatically in certain cases of abnormal vision, such as amblyopia (Ginsburg, 1978, 1981; Hess, Bradley and Piotrowski, 1983; Loshin and Levi, 1983). The...combination of frequencies. Amblyopia results in marked losses of contrast sensitivity particularly at high spatial frequencies, but may also result in
A Vision in Aeronautics: The K-12 Wind Tunnel Project
NASA Technical Reports Server (NTRS)
1997-01-01
A Vision in Aeronautics, a project within the NASA Lewis Research Center's Information Infrastructure Technologies and Applications (IITA) K-12 Program, employs small-scale, subsonic wind tunnels to inspire students to explore the world of aeronautics and computers. Recently, two educational K-12 wind tunnels were built in the Cleveland area. During the 1995-1996 school year, preliminary testing occurred in both tunnels.
Overview of machine vision methods in x-ray imaging and microtomography
NASA Astrophysics Data System (ADS)
Buzmakov, Alexey; Zolotov, Denis; Chukalina, Marina; Nikolaev, Dmitry; Gladkov, Andrey; Ingacheva, Anastasia; Yakimchuk, Ivan; Asadchikov, Victor
2018-04-01
Digital X-ray imaging became widely used in science, medicine, non-destructive testing. This allows using modern digital images analysis for automatic information extraction and interpretation. We give short review of scientific applications of machine vision in scientific X-ray imaging and microtomography, including image processing, feature detection and extraction, images compression to increase camera throughput, microtomography reconstruction, visualization and setup adjustment.
Enhanced and Synthetic Vision for Terminal Maneuvering Area NextGen Operations
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Bailey, Randall E.; Ellis, Kyle K. E.; Norman, R. Michael; Williams, Steven P.; Arthur, Jarvis J., III; Shelton, Kevin J.; Prinzel, Lawrence J., III
2011-01-01
Synthetic Vision Systems and Enhanced Flight Vision System (SVS/EFVS) technologies have the potential to provide additional margins of safety for aircrew performance and enable operational improvements for low visibility operations in the terminal area environment with equivalent efficiency as visual operations. To meet this potential, research is needed for effective technology development and implementation of regulatory and design guidance to support introduction and use of SVS/EFVS advanced cockpit vision technologies in Next Generation Air Transportation System (NextGen) operations. A fixed-base pilot-in-the-loop simulation test was conducted at NASA Langley Research Center that evaluated the use of SVS/EFVS in NextGen low visibility ground (taxi) operations and approach/landing operations. Twelve crews flew approach and landing operations in a simulated NextGen Chicago O Hare environment. Various scenarios tested the potential for EFVS for operations in visibility as low as 1000 ft runway visibility range (RVR) and SVS to enable lower decision heights (DH) than can currently be flown today. Expanding the EFVS visual segment from DH to the runway in visibilities as low as 1000 RVR appears to be viable as touchdown performance was excellent without any workload penalties noted for the EFVS concept tested. A lower DH to 150 ft and/or possibly reduced visibility minima by virtue of SVS equipage appears to be viable when implemented on a Head-Up Display, but the landing data suggests further study for head-down implementations.
APFELBAUM, HENRY; PELAH, ADAR; PELI, ELI
2007-01-01
Virtual reality locomotion simulators are a promising tool for evaluating the effectiveness of vision aids to mobility for people with low vision. This study examined two factors to gain insight into the verisimilitude requirements of the test environment: the effects of treadmill walking and the suitability of using controls as surrogate patients. Ten “tunnel vision” patients with retinitis pigmentosa (RP) were tasked with identifying which side of a clearly visible obstacle their heading through the virtual environment would lead them, and were scored both on accuracy and on their distance from the obstacle when they responded. They were tested both while walking on a treadmill and while standing, as they viewed a scene representing progress through a shopping mall. Control subjects, each wearing a head-mounted field restriction to simulate the vision of a paired patient, were also tested. At wide angles of approach, controls and patients performed with a comparably high degree of accuracy, and made their choices at comparable distances from the obstacle. At narrow angles of approach, patients’ accuracy increased when walking, while controls’ accuracy decreased. When walking, both patients and controls delayed their decisions until closer to the obstacle. We conclude that a head-mounted field restriction is not sufficient for simulating tunnel vision, but that the improved performance observed for walking compared to standing suggests that a walking interface (such as a treadmill) may be essential for eliciting natural perceptually-guided behavior in virtual reality locomotion simulators. PMID:18167511
Welinder, Lotte G; Baggesen, Kirsten L
2012-12-01
To investigate the visual abilities of students with severe developmental delay (DD) age 6-8 starting in special needs education. Between 1 January 2000 and 31 December 2008, we screened all students with severe DD starting in special needs schools in Northern Jutland, Denmark for vision. All students with visual acuities ≤6/12 were refractioned and examined by an ophthalmologist. Of 502 students, 56 (11%) had visual impairment (VI) [visual acuity (VA) ≤ 6/18], of which 21 had been previously undiagnosed. Legal blindness was found in 15 students (3%), of whom three had previously been undiagnosed. Students tested with preferential looking systems (N = 78) had significantly lower visual acuities [VA (decimal) = 0.55] than students tested with ortho types [VA (decimal) = 0.91] and had problems participating in the colour and form tests, possibly due to cerebral VI. The number of students with decreased vision identified by screening decreased significantly during the study period (r = 0.724, p = 0.028). The number of students needed to be screened to find one student with VI was 24 and to identify legal blindness 181 needed to be screened. Visual impairment is a common condition in students with severe DD. Despite increased awareness of VI in the school and health care system, we continued to find a considerable number of students with hitherto undiagnosed decreased vision. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
16 CFR 1203.12 - Test requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test requirements. 1203.12 Section 1203.12... STANDARD FOR BICYCLE HELMETS The Standard § 1203.12 Test requirements. (a) Peripheral vision. All bicycle... bicycle helmet shall come off of the test headform when tested in accordance with § 1203.15 of this...
Indoor Spatial Updating With Impaired Vision
Legge, Gordon E.; Granquist, Christina; Baek, Yihwa; Gage, Rachel
2016-01-01
Purpose Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Methods Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. Results The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. Conclusions People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient. PMID:27978556
Indoor Spatial Updating With Impaired Vision.
Legge, Gordon E; Granquist, Christina; Baek, Yihwa; Gage, Rachel
2016-12-01
Spatial updating is the ability to keep track of position and orientation while moving through an environment. We asked how normally sighted and visually impaired subjects compare in spatial updating and in estimating room dimensions. Groups of 32 normally sighted, 16 low-vision, and 16 blind subjects estimated the dimensions of six rectangular rooms. Updating was assessed by guiding the subjects along three-segment paths in the rooms. At the end of each path, they estimated the distance and direction to the starting location, and to a designated target. Spatial updating was tested in five conditions ranging from free viewing to full auditory and visual deprivation. The normally sighted and low-vision groups did not differ in their accuracy for judging room dimensions. Correlations between estimated size and physical size were high. Accuracy of low-vision performance was not correlated with acuity, contrast sensitivity, or field status. Accuracy was lower for the blind subjects. The three groups were very similar in spatial-updating performance, and exhibited only weak dependence on the nature of the viewing conditions. People with a wide range of low-vision conditions are able to judge room dimensions as accurately as people with normal vision. Blind subjects have difficulty in judging the dimensions of quiet rooms, but some information is available from echolocation. Vision status has little impact on performance in simple spatial updating; proprioceptive and vestibular cues are sufficient.
Beckman, Stella; Eisen, Ellen A.; Bates, Michael N.; Liu, Sa; Haegerstrom-Portnoy, Gunilla; Hammond, S. Katharine
2016-01-01
Occupational exposure to solvents, including n-hexane, has been associated with acquired color vision defects. Blue-yellow defects are most common and may be due to neurotoxicity or retinal damage. Acetone may potentiate the neurotoxicity of n-hexane. We present results on nonhexane solvent and hexane exposure and color vision from a cross-sectional study of 835 automotive repair workers in the San Francisco Bay Area, California (2007–2013). Cumulative exposure was estimated from self-reported work history, and color vision was assessed using the Lanthony desaturated D-15 panel test. Log-binomial regression was used to estimate prevalence ratios for color vision defects. Acquired color vision defects were present in 29% of participants, of which 70% were blue-yellow. Elevated prevalence ratios were found for nonhexane solvent exposure, with a maximum of 1.31 (95% confidence interval (CI): 0.86, 2.00) for blue-yellow. Among participants aged ≤50 years, the prevalence ratio for blue-yellow defects was 2.17 (95% CI: 1.03, 4.56) in the highest quartile of nonhexane solvent exposure and 1.62 (95% CI: 0.97, 2.72) in the highest category of exposure to hexane with acetone coexposure. Cumulative exposures to hexane and nonhexane solvents in the highest exposure categories were associated with elevated prevalence ratios for color vision defects in younger participants. PMID:27188942
Community screening for visual impairment in older people.
Clarke, Emily L; Evans, Jennifer R; Smeeth, Liam
2018-02-20
Visual problems in older people are common and frequently under-reported. The effects of poor vision in older people are wide reaching and include falls, confusion and reduced quality of life. Much of the visual impairment in older ages can be treated (e.g. cataract surgery, correction of refractive error). Vision screening may therefore reduce the number of older people living with sight loss. The objective of this review was to assess the effects on vision of community vision screening of older people for visual impairment. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 10); Ovid MEDLINE; Ovid Embase; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 23 November 2017. We included randomised controlled trials (RCTs) that compared vision screening alone or as part of a multi-component screening package as compared to no vision screening or standard care, on the vision of people aged 65 years or over in a community setting. We included trials that used self-reported visual problems or visual acuity testing as the screening tool. We used standard methods expected by Cochrane. We graded the certainty of the evidence using GRADE. Visual outcome data were available for 10,608 people in 10 trials. Four trials took place in the UK, two in Australia, two in the United States and two in the Netherlands. Length of follow-up ranged from one to five years. Three of these studies were cluster-randomised trials whereby general practitioners or family physicians were randomly allocated to undertake vision screening or no vision screening. All studies were funded by government agencies. Overall we judged the studies to be at low risk of bias and only downgraded the certainty of the evidence (GRADE) for imprecision.Seven trials compared vision screening as part of a multi-component screening versus no screening. Six of these studies used self-reported vision as both screening tool and outcome measure, but did not directly measure vision. One study used a combination of self-reported vision and visual acuity measurement: participants reporting vision problems at screening were treated by the attending doctor, referred to an eye care specialist or given information about resources that were available to assist with poor vision. There was a similar risk of "not seeing well" at follow-up in people screened compared with people not screened in meta-analysis of six studies (risk ratio (RR) 1.05, 95% confidence interval (CI) 0.97 to 1.14, 4522 participants high-certainty evidence). One trial reported "improvement in vision" and this occurred slightly less frequently in the screened group (RR 0.85, 95% CI 0.52 to 1.40, 230 participants, moderate-certainty evidence).Two trials compared vision screening (visual acuity testing) alone with no vision screening. In one study, distance visual acuity was similar in the two groups at follow-up (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.05, 532 participants, high-certainty evidence). There was also little difference in near acuity (MD 0.02 logMAR, 95% CI -0.03 to 0.07, 532 participants, high-certainty evidence). There was no evidence of any important difference in quality of life (MD -0.06 National Eye Institute 25-item visual function questionnaire (VFQ-25) score adjusted for baseline VFQ-25 score, 95% CI -2.3 to 1.1, 532 participants, high-certainty evidence). The other study could not be included in the data analysis as the number of participants in each of the arms at follow-up could not be determined. However the authors stated that there was no significant difference in mean visual acuity in participants who had visual acuity assessed at baseline (39 letters) as compared to those who did not have their visual acuity assessed (35 letters, P = 0.25, 121 participants).One trial compared a detailed health assessment including measurement of visual acuity (intervention) with a brief health assessment including one question about vision (standard care). People given the detailed health assessment had a similar risk of visual impairment (visual acuity worse than 6/18 in either eye) at follow-up compared with people given the brief assessment (RR 1.07, 95% CI 0.84 to 1.36, 1807 participants, moderate-certainty evidence). The mean composite score of the VFQ-25 was 86.0 in the group that underwent visual acuity screening compared with 85.6 in the standard care group, a difference of 0.40 (95% CI -1.70 to 2.50, 1807 participants, high-certainty evidence). The evidence from RCTs undertaken to date does not support vision screening for older people living independently in a community setting, whether in isolation or as part of a multi-component screening package. This is true for screening programmes involving questions about visual problems, or direct measurements of visual acuity.The most likely reason for this negative review is that the populations within the trials often did not take up the offered intervention as a result of the vision screening and large proportions of those who did not have vision screening appeared to seek their own intervention. Also, trials that use questions about vision have a lower sensitivity and specificity than formal visual acuity testing. Given the importance of visual impairment among older people, further research into strategies to improve vision of older people is needed. The effectiveness of an optimised primary care-based screening intervention that overcomes possible factors contributing to the observed lack of benefit in trials to date warrants assessment; trials should consider including more dependent participants, rather than those living independently in the community.
Validity and Acceptance of Color Vision Testing on Smartphones.
Ozgur, Omar K; Emborgo, Trisha S; Vieyra, Mark B; Huselid, Rebecca F; Banik, Rudrani
2018-03-01
Ishihara color plates (ICP) are the most commonly used color vision test (CVT) worldwide. With the advent of new technologies, attempts have been made to streamline the process of CVT. As hardware and software evolve, smartphone-based testing modalities may aid ophthalmologists in performing more efficient ophthalmic examinations. We assess the validity of smartphone color vision testing (CVT) by comparing results using the Eye Handbook (EHB) CVT application with standard Ishihara color plates (ICP). Prospective case-control study of subjects 18 years and older with visual acuity of 20/100 or better at 14 inches. The study group included patients with any ocular pathology. The color vision deficient (CVD) group was patients who failed more than 2 plates. The control group had no known ocular pathology. CVT was performed with both ICP and EHB under standardized background illuminance. Eleven plates were tested with each modality. Validity of EHB CVT and acceptance of EHB CVT were analyzed. Statistical analyses were performed using Bland-Altman plot with limits of agreement (LOA) at the 95th percentile of differences in score, independent samples t tests with 95% confidence interval (CI), and Pearson χ tests. The Bland-Altman plot showed agreement between correct number of plates in EHB and ICP for the study subjects (bias, -0.25; LOA, -1.92 to 1.42). Agreement was also observed between the correct number of plates in EHB and ICP for the controls (bias, -0.01; LOA, -0.61 to 0.59) and CVD (bias, -0.50; LOA, -4.64 to 3.64) subjects. The sensitivity of EHB was 0.92 (95% CI 0.76-1.07) and the specificity of EHB was 1.00 (95% CI 1.00-1.00). Fifty-nine percent preferred EHB, 12% preferred ICP, and 29% had no preference. In healthy controls and patients with ocular pathology, there was an agreement of CVT results comparing EHB with ICP. Overall, the majority preferred EHB to ICP. These findings demonstrate that further testing is required to understand and improve the validity of smartphone CVT in subjects with ocular pathology.
Parallel inputs to memory in bee colour vision.
Horridge, Adrian
2016-03-01
In the 19(th) century, it was found that attraction of bees to light was controlled by light intensity irrespective of colour, and a few critical entomologists inferred that vision of bees foraging on flowers was unlike human colour vision. Therefore, quite justly, Professor Carl von Hess concluded in his book on the Comparative Physiology of Vision (1912) that bees do not distinguish colours in the way that humans enjoy. Immediately, Karl von Frisch, an assistant in the Zoology Department of the same University of Münich, set to work to show that indeed bees have colour vision like humans, thereby initiating a new research tradition, and setting off a decade of controversy that ended only at the death of Hess in 1923. Until 1939, several researchers continued the tradition of trying to untangle the mechanism of bee vision by repeatedly testing trained bees, but made little progress, partly because von Frisch and his legacy dominated the scene. The theory of trichromatic colour vision further developed after three types of receptors sensitive to green, blue, and ultraviolet (UV), were demonstrated in 1964 in the bee. Then, until the end of the century, all data was interpreted in terms of trichromatic colour space. Anomalies were nothing new, but eventually after 1996 they led to the discovery that bees have a previously unknown type of colour vision based on a monochromatic measure and distribution of blue and measures of modulation in green and blue receptor pathways. Meanwhile, in the 20(th) century, search for a suitable rationalization, and explorations of sterile culs-de-sac had filled the literature of bee colour vision, but were based on the wrong theory.
Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka
2013-09-01
To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P < 0.05 was considered significant. LogMAR visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P < 0.0001) and near (0.42 ± 0.17; P = 0.001). The most common reported difficulties were related to their academic activities like copying from the blackboard (80%), reading textbook at arm's length (77.2%), and writing along a straight line (77.2%). Absolute raw score of disability pre-LVD was 15.05 which improved to 7.58 post-LVD. An improvement in functional vision post visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P < 0.0001), reading textbook at arm's length (P < 0.0001), and writing along a straight line (P = 0.003). In our study group, there was a significant improvement in functional vision post visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.
Testing vision with angular and radial multifocal designs using Adaptive Optics.
Vinas, Maria; Dorronsoro, Carlos; Gonzalez, Veronica; Cortes, Daniel; Radhakrishnan, Aiswaryah; Marcos, Susana
2017-03-01
Multifocal vision corrections are increasingly used solutions for presbyopia. In the current study we have evaluated, optically and psychophysically, the quality provided by multizone radial and angular segmented phase designs. Optical and relative visual quality were evaluated using 8 subjects, testing 6 phase designs. Optical quality was evaluated by means of Visual Strehl-based-metrics (VS). The relative visual quality across designs was obtained through a psychophysical paradigm in which images viewed through 210 pairs of phase patterns were perceptually judged. A custom-developed Adaptive Optics (AO) system, including a Hartmann-Shack sensor and an electromagnetic deformable mirror, to measure and correct the eye's aberrations, and a phase-only reflective Spatial Light Modulator, to simulate the phase designs, was developed for this study. The multizone segmented phase designs had 2-4 zones of progressive power (0 to +3D) in either radial or angular distributions. The response of an "ideal observer" purely responding on optical grounds to the same psychophysical test performed on subjects was calculated from the VS curves, and compared with the relative visual quality results. Optical and psychophysical pattern-comparison tests showed that while 2-zone segmented designs (angular & radial) provided better performance for far and near vision, 3- and 4-zone segmented angular designs performed better for intermediate vision. AO-correction of natural aberrations of the subjects modified the response for the different subjects but general trends remained. The differences in perceived quality across the different multifocal patterns are, in a large extent, explained by optical factors. AO is an excellent tool to simulate multifocal refractions before they are manufactured or delivered to the patient, and to assess the effects of the native optics to their performance. Copyright © 2016 Elsevier Ltd. All rights reserved.
A Monocular Vision Measurement System of Three-Degree-of-Freedom Air-Bearing Test-Bed Based on FCCSP
NASA Astrophysics Data System (ADS)
Gao, Zhanyu; Gu, Yingying; Lv, Yaoyu; Xu, Zhenbang; Wu, Qingwen
2018-06-01
A monocular vision-based pose measurement system is provided for real-time measurement of a three-degree-of-freedom (3-DOF) air-bearing test-bed. Firstly, a circular plane cooperative target is designed. An image of a target fixed on the test-bed is then acquired. Blob analysis-based image processing is used to detect the object circles on the target. A fast algorithm (FCCSP) based on pixel statistics is proposed to extract the centers of object circles. Finally, pose measurements can be obtained when combined with the centers and the coordinate transformation relation. Experiments show that the proposed method is fast, accurate, and robust enough to satisfy the requirement of the pose measurement.
Automated spot defect characterization in a field portable night vision goggle test set
NASA Astrophysics Data System (ADS)
Scopatz, Stephen; Ozten, Metehan; Aubry, Gilles; Arquetoux, Guillaume
2018-05-01
This paper discusses a new capability developed for and results from a field portable test set for Gen 2 and Gen 3 Image Intensifier (I2) tube-based Night Vision Goggles (NVG). A previous paper described the test set and the automated and semi-automated tests supported for NVGs including a Knife Edge MTF test to replace the operator's interpretation of the USAF 1951 resolution chart. The major improvement and innovation detailed in this paper is the use of image analysis algorithms to automate the characterization of spot defects of I² tubes with the same test set hardware previously presented. The original and still common Spot Defect Test requires the operator to look through the NVGs at target of concentric rings; compare the size of the defects to a chart and manually enter the results into a table based on the size and location of each defect; this is tedious and subjective. The prior semi-automated improvement captures and displays an image of the defects and the rings; allowing the operator determine the defects with less eyestrain; while electronically storing the image and the resulting table. The advanced Automated Spot Defect Test utilizes machine vision algorithms to determine the size and location of the defects, generates the result table automatically and then records the image and the results in a computer-generated report easily usable for verification. This is inherently a more repeatable process that ensures consistent spot detection independent of the operator. Results of across several NVGs will be presented.
Quinn, Terence J; Livingstone, Iain; Weir, Alexander; Shaw, Robert; Breckenridge, Andrew; McAlpine, Christine; Tarbert, Claire M
2018-01-01
Visual impairment affects up to 70% of stroke survivors. We designed an app (StrokeVision) to facilitate screening for common post stroke visual issues (acuity, visual fields, and visual inattention). We sought to describe the test time, feasibility, acceptability, and accuracy of our app-based digital visual assessments against (a) current methods used for bedside screening and (b) gold standard measures. Patients were prospectively recruited from acute stroke settings. Index tests were app-based assessments of fields and inattention performed by a trained researcher. We compared against usual clinical screening practice of visual fields to confrontation, including inattention assessment (simultaneous stimuli). We also compared app to gold standard assessments of formal kinetic perimetry (Goldman or Octopus Visual Field Assessment); and pencil and paper-based tests of inattention (Albert's, Star Cancelation, and Line Bisection). Results of inattention and field tests were adjudicated by a specialist Neuro-ophthalmologist. All assessors were masked to each other's results. Participants and assessors graded acceptability using a bespoke scale that ranged from 0 (completely unacceptable) to 10 (perfect acceptability). Of 48 stroke survivors recruited, the complete battery of index and reference tests for fields was successfully completed in 45. Similar acceptability scores were observed for app-based [assessor median score 10 (IQR: 9-10); patient 9 (IQR: 8-10)] and traditional bedside testing [assessor 10 (IQR: 9-10); patient 10 (IQR: 9-10)]. Median test time was longer for app-based testing [combined time to completion of all digital tests 420 s (IQR: 390-588)] when compared with conventional bedside testing [70 s, (IQR: 40-70)], but shorter than gold standard testing [1,260 s, (IQR: 1005-1,620)]. Compared with gold standard assessments, usual screening practice demonstrated 79% sensitivity and 82% specificity for detection of a stroke-related field defect. This compares with 79% sensitivity and 88% specificity for StrokeVision digital assessment. StrokeVision shows promise as a screening tool for visual complications in the acute phase of stroke. The app is at least as good as usual screening and offers other functionality that may make it attractive for use in acute stroke. https://ClinicalTrials.gov/ct2/show/NCT02539381.
Quantitative systems toxicology
Bloomingdale, Peter; Housand, Conrad; Apgar, Joshua F.; Millard, Bjorn L.; Mager, Donald E.; Burke, John M.; Shah, Dhaval K.
2017-01-01
The overarching goal of modern drug development is to optimize therapeutic benefits while minimizing adverse effects. However, inadequate efficacy and safety concerns remain to be the major causes of drug attrition in clinical development. For the past 80 years, toxicity testing has consisted of evaluating the adverse effects of drugs in animals to predict human health risks. The U.S. Environmental Protection Agency recognized the need to develop innovative toxicity testing strategies and asked the National Research Council to develop a long-range vision and strategy for toxicity testing in the 21st century. The vision aims to reduce the use of animals and drug development costs through the integration of computational modeling and in vitro experimental methods that evaluates the perturbation of toxicity-related pathways. Towards this vision, collaborative quantitative systems pharmacology and toxicology modeling endeavors (QSP/QST) have been initiated amongst numerous organizations worldwide. In this article, we discuss how quantitative structure-activity relationship (QSAR), network-based, and pharmacokinetic/pharmacodynamic modeling approaches can be integrated into the framework of QST models. Additionally, we review the application of QST models to predict cardiotoxicity and hepatotoxicity of drugs throughout their development. Cell and organ specific QST models are likely to become an essential component of modern toxicity testing, and provides a solid foundation towards determining individualized therapeutic windows to improve patient safety. PMID:29308440
Ryan, Denise S; Sia, Rose K; Stutzman, Richard D; Pasternak, Joseph F; Howard, Robin S; Howell, Christopher L; Maurer, Tana; Torres, Mark F; Bower, Kraig S
2017-01-01
To compare visual performance, marksmanship performance, and threshold target identification following wavefront-guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK). In this prospective, randomized clinical trial, active duty U.S. military Soldiers, age 21 or over, electing to undergo PRK were randomized to undergo WFG (n = 27) or WFO (n = 27) PRK for myopia or myopic astigmatism. Binocular visual performance was assessed preoperatively and 1, 3, and 6 months postoperatively: Super Vision Test high contrast, Super Vision Test contrast sensitivity (CS), and 25% contrast acuity with night vision goggle filter. CS function was generated testing at five spatial frequencies. Marksmanship performance in low light conditions was evaluated in a firing tunnel. Target detection and identification performance was tested for probability of identification of varying target sets and probability of detection of humans in cluttered environments. Visual performance, CS function, marksmanship, and threshold target identification demonstrated no statistically significant differences over time between the two treatments. Exploratory regression analysis of firing range tasks at 6 months showed no significant differences or correlations between procedures. Regression analysis of vehicle and handheld probability of identification showed a significant association with pretreatment performance. Both WFG and WFO PRK results translate to excellent and comparable visual and military performance. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Leo, Fabrizio; Cocchi, Elena; Brayda, Luca
2017-07-01
Vision loss has severe impacts on physical, social and emotional well-being. The education of blind children poses issues as many scholar disciplines (e.g., geometry, mathematics) are normally taught by heavily relying on vision. Touch-based assistive technologies are potential tools to provide graphical contents to blind users, improving learning possibilities and social inclusion. Raised-lines drawings are still the golden standard, but stimuli cannot be reconfigured or adapted and the blind person constantly requires assistance. Although much research concerns technological development, little work concerned the assessment of programmable tactile graphics, in educative and rehabilitative contexts. Here we designed, on programmable tactile displays, tests aimed at assessing spatial memory skills and shapes recognition abilities. Tests involved a group of blind and a group of low vision children and adolescents in a four-week longitudinal schedule. After establishing subject-specific difficulty levels, we observed a significant enhancement of performance across sessions and for both groups. Learning effects were comparable to raised paper control tests: however, our setup required minimal external assistance. Overall, our results demonstrate that programmable maps are an effective way to display graphical contents in educative/rehabilitative contexts. They can be at least as effective as traditional paper tests yet providing superior flexibility and versatility.
Enhanced modeling and simulation of EO/IR sensor systems
NASA Astrophysics Data System (ADS)
Hixson, Jonathan G.; Miller, Brian; May, Christopher
2015-05-01
The testing and evaluation process developed by the Night Vision and Electronic Sensors Directorate (NVESD) Modeling and Simulation Division (MSD) provides end to end systems evaluation, testing, and training of EO/IR sensors. By combining NV-LabCap, the Night Vision Integrated Performance Model (NV-IPM), One Semi-Automated Forces (OneSAF) input sensor file generation, and the Night Vision Image Generator (NVIG) capabilities, NVESD provides confidence to the M&S community that EO/IR sensor developmental and operational testing and evaluation are accurately represented throughout the lifecycle of an EO/IR system. This new process allows for both theoretical and actual sensor testing. A sensor can be theoretically designed in NV-IPM, modeled in NV-IPM, and then seamlessly input into the wargames for operational analysis. After theoretical design, prototype sensors can be measured by using NV-LabCap, then modeled in NV-IPM and input into wargames for further evaluation. The measurement process to high fidelity modeling and simulation can then be repeated again and again throughout the entire life cycle of an EO/IR sensor as needed, to include LRIP, full rate production, and even after Depot Level Maintenance. This is a prototypical example of how an engineering level model and higher level simulations can share models to mutual benefit.
Vision screening of older drivers for preventing road traffic injuries and fatalities.
Desapriya, Ediriweera; Harjee, Rahana; Brubacher, Jeffrey; Chan, Herbert; Hewapathirane, D Sesath; Subzwari, Sayed; Pike, Ian
2014-02-21
Demographic data in North America, Europe, Asia, Australia and New Zealand suggest a rapid growth in the number of persons over the age of 65 years as the baby boomer generation passes retirement age. As older adults make up an increasing proportion of the population, they are an important consideration when designing future evidence-based traffic safety policies, particularly those that lead to restrictions or cessation of driving. Research has shown that cessation of driving among older drivers can lead to negative emotional consequences such as depression and loss of independence. Older adults who continue to drive tend to do so less frequently than other demographic groups and are more likely to be involved in a road traffic crash, possibly due to what is termed the "low mileage bias". Available research suggests that older driver crash risk estimates based on traditional exposure measures are prone to bias. When annual driving distances are taken in to consideration, older drivers with low driving distances have an increased crash risk, while those with average or high driving distances tend to be safer drivers when compared to other age groups. In addition, older drivers with lower distance driving tend to drive in urban areas which, due to more complex and demanding traffic patterns, tend to be more accident-prone. Failure to control for actual annual driving distances and driving locations among older drivers is referred to as "low mileage bias" in older driver mobility research. It is also important to note that older drivers are more vulnerable to serious injury and death in the event of a traffic crash due to changes in physiology associated with normal ageing. Vision, cognition, and motor functions or skills (e.g., strength, co-ordination, and flexibility) are three key domains required for safe driving. To drive safely, an individual needs to be able to see road signs, road side objects, traffic lights, roadway markings, other vulnerable road users, and other vehicles on the road, among many other cues-all while moving, and under varying light and weather conditions. It is equally important that drivers must have appropriate peripheral vision to monitor objects and movement to identify possible threats in the driving environment. It is, therefore, not surprising that there is agreement among researchers that vision plays a significant role in driving performance. Several age-related processes/conditions impair vision, thus it follows that vision testing of older drivers is an important road safety issue. The components of visual function essential for driving are acuity, static acuity, dynamic acuity, visual fields, visual attention, depth perception, and contrast sensitivity. These indices are typically not fully assessed by licensing agencies. Also, current vision screening regulations and cut-off values required to pass a licensing test vary from country to country. Although there is a clear need to develop evidence-based and validated tools for vision screening for driving, the effectiveness of existing vision screening tools remains unclear. This represents an important and highly warranted initiative to increase road safety worldwide. To assess the effects of vision screening interventions for older drivers to prevent road traffic injuries and fatalities. For the update of this review we searched the Cochrane Injuries Group's Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), MEDLINE (OvidSP), Embase (OvidSP), PsycINFO (OvidSP) and ISI Web of Science: (CPCI-S & SSCI). The searches were conducted up to 26 September 2013. Randomised controlled trials (RCTs) and controlled before and after studies comparing vision screening to non-screening of drivers aged 55 years and older, and which assessed the effect on road traffic crashes, injuries, fatalities and any involvement in traffic law violations. Two review authors independently screened the reference lists for eligible articles and independently assessed the articles for inclusion against the criteria. If suitable trials had been available, two review authors would have independently extracted data using a standardised extraction form. No studies were found that met the inclusion criteria for this review. Most countries require a vision screening test for the renewal of an individual's driver's licence. There is, however, lack of methodologically sound studies to assess the effects of vision screening tests on subsequent motor vehicle crash reduction. There is a need to develop valid and reliable tools of vision screening that can predict driving performance.
Looking above the prairie: localized and upward acute vision in a native grassland bird.
Tyrrell, Luke P; Moore, Bret A; Loftis, Christopher; Fernández-Juricic, Esteban
2013-12-02
Visual systems of open habitat vertebrates are predicted to have a band of acute vision across the retina (visual streak) and wide visual coverage to gather information along the horizon. We tested whether the eastern meadowlark (Sturnella magna) had this visual configuration given that it inhabits open grasslands. Contrary to our expectations, the meadowlark retina has a localized spot of acute vision (fovea) and relatively narrow visual coverage. The fovea projects above rather than towards the horizon with the head at rest, and individuals modify their body posture in tall grass to maintain a similar foveal projection. Meadowlarks have relatively large binocular fields and can see their bill tips, which may help with their probe-foraging technique. Overall, meadowlark vision does not fit the profile of vertebrates living in open habitats. The binocular field may control foraging while the fovea may be used for detecting and tracking aerial stimuli (predators, conspecifics).
Technical Challenges in the Development of a NASA Synthetic Vision System Concept
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Parrish, Russell V.; Kramer, Lynda J.; Harrah, Steve; Arthur, J. J., III
2002-01-01
Within NASA's Aviation Safety Program, the Synthetic Vision Systems Project is developing display system concepts to improve pilot terrain/situation awareness by providing a perspective synthetic view of the outside world through an on-board database driven by precise aircraft positioning information updating via Global Positioning System-based data. This work is aimed at eliminating visibility-induced errors and low visibility conditions as a causal factor to civil aircraft accidents, as well as replicating the operational benefits of clear day flight operations regardless of the actual outside visibility condition. Synthetic vision research and development activities at NASA Langley Research Center are focused around a series of ground simulation and flight test experiments designed to evaluate, investigate, and assess the technology which can lead to operational and certified synthetic vision systems. The technical challenges that have been encountered and that are anticipated in this research and development activity are summarized.
Color Vision Losses in Autism Spectrum Disorders
Zachi, Elaine C.; Costa, Thiago L.; Barboni, Mirella T. S.; Costa, Marcelo F.; Bonci, Daniela M. O.; Ventura, Dora F.
2017-01-01
Autism spectrum disorders (ASDs) are neurodevelopmental conditions characterized by impairments in social/communication abilities and restricted behaviors. The present study aims to examine color vision discrimination in ASD children and adolescents without intellectual disability. The participants were also subdivided in order to compare color vision thresholds of autistic participants and those who achieved diagnostic criteria for Asperger Syndrome (AS). Nine subjects with autism, 11 participants with AS and 36 typically developing children and adolescents participated in the study. Color vision was assessed by the Cambridge Color Test (CCT). The Trivector protocol was administered to determine color discrimination thresholds along the protan, deutan, and tritan color confusion lines. Data from ASD participants were compared to tolerance limits for 90% of the population with 90% probability obtained from controls thresholds. Of the 20 ASD individuals examined, 6 (30%) showed color vision losses. Elevated color discrimination thresholds were found in 3/9 participants with autism and in 3/11 AS participants. Diffuse and tritan deficits were found. Mechanisms for chromatic losses may be either at the retinal level and/or reflect reduced cortical integration. PMID:28713324
Emotion-induced trade-offs in spatiotemporal vision.
Bocanegra, Bruno R; Zeelenberg, René
2011-05-01
It is generally assumed that emotion facilitates human vision in order to promote adaptive responses to a potential threat in the environment. Surprisingly, we recently found that emotion in some cases impairs the perception of elementary visual features (Bocanegra & Zeelenberg, 2009b). Here, we demonstrate that emotion improves fast temporal vision at the expense of fine-grained spatial vision. We tested participants' threshold resolution with Landolt circles containing a small spatial or brief temporal discontinuity. The prior presentation of a fearful face cue, compared with a neutral face cue, impaired spatial resolution but improved temporal resolution. In addition, we show that these benefits and deficits were triggered selectively by the global configural properties of the faces, which were transmitted only through low spatial frequencies. Critically, the common locus of these opposite effects suggests a trade-off between magno- and parvocellular-type visual channels, which contradicts the common assumption that emotion invariably improves vision. We show that, rather than being a general "boost" for all visual features, affective neural circuits sacrifice the slower processing of small details for a coarser but faster visual signal.
... normal skin and hair Patches of missing skin color Many forms of albinism are associated with the following symptoms: Crossed eyes Light sensitivity Rapid eye movements Vision problems, or functional blindness Exams and Tests Genetic testing offers the most ...
Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie
2017-02-01
Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): -4.19, -1.42) and 4.26s longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: -3.30, -1.21) than those without impaired near vision. Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie
2016-01-01
Objectives Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. Study design In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. Main Outcome Measures At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Results Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): −4.19,−1.42) and 4.26 seconds longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: −3.30,−1.21) than those without impaired near vision. Conclusion Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. PMID:28041592
Pelletier, Allen L; Rojas-Roldan, Ledy; Coffin, Janis
2016-08-01
Vision loss affects 37 million Americans older than 50 years and one in four who are older than 80 years. The U.S. Preventive Services Task Force concludes that current evidence is insufficient to assess the balance of benefits and harms of screening for impaired visual acuity in adults older than 65 years. However, family physicians play a critical role in identifying persons who are at risk of vision loss, counseling patients, and referring patients for disease-specific treatment. The conditions that cause most cases of vision loss in older patients are age-related macular degeneration, glaucoma, ocular complications of diabetes mellitus, and age-related cataracts. Vitamin supplements can delay the progression of age-related macular degeneration. Intravitreal injection of a vascular endothelial growth factor inhibitor can preserve vision in the neovascular form of macular degeneration. Medicated eye drops reduce intraocular pressure and can delay the progression of vision loss in patients with glaucoma, but adherence to treatment is poor. Laser trabeculoplasty also lowers intraocular pressure and preserves vision in patients with primary open-angle glaucoma, but long-term studies are needed to identify who is most likely to benefit from surgery. Tight glycemic control in adults with diabetes slows the progression of diabetic retinopathy, but must be balanced against the risks of hypoglycemia and death in older adults. Fenofibrate also slows progression of diabetic retinopathy. Panretinal photocoagulation is the mainstay of treatment for diabetic retinopathy, whereas vascular endothelial growth factor inhibitors slow vision loss resulting from diabetic macular edema. Preoperative testing before cataract surgery does not improve outcomes and is not recommended.
Coordination exercise and postural stability in elderly people: Effect of Tai Chi Chuan.
Wong, A M; Lin, Y C; Chou, S W; Tang, F T; Wong, P Y
2001-05-01
To evaluate the effects of coordination exercise on postural stability in older individuals by Chinese shadow boxing, Tai Chi Chuan (TCC). Cross-sectional study. Research project in a hospital-based biomechanical laboratory. The TCC group (n = 25) had been practicing TCC regularly for 2 to 35 years. The control group (n = 14) included healthy and active older subjects. Static postural stability test: progressively harder sequential tests with 6 combinations of vision (eyes open, eyes closed, sway-referenced) and support (fixed, sway-referenced); and dynamic balance test: 3 tests of weight shifting (left to right, forward-backward, multidirectional) at 3 speeds. Static and dynamic balance of Sensory Organization Testing (SOT) of the Smart Balance Master System. In static postural control, the results showed no differences between the TCC or control group in the more simple conditions, but in the more complicated SOT (eyes closed with sway surface, sway vision with sway surface), the TCC group had significantly better results than the control group. The TCC group also had significantly better results in the rhythmic forward-backward weight-shifting test. Duration of practice did not seem to affect the stability of elder people. The elderly people who regularly practiced TCC showed better postural stability in the more challenged conditions than those who do not (eg, the condition with simultaneous disturbance of vision and proprioception). TCC as a coordination exercise may reduce the risk of a fall through maintaining the ability of posture control.
NASA UTILIZATION OF THE INTERNATIONAL SPACE STATION AND THE VISION FOR SPACE EXPLORATION
NASA Technical Reports Server (NTRS)
Robinson, Julie A.; Thomas, Donald A.
2006-01-01
Under U.S. President Bush s Vision for Space Exploration (January 14, 2004), NASA has refocused its utilization plans for the International Space Station (ISS). This use will now focus on: (1) the development of countermeasures that will protect crews from the hazards of the space environment, (2) testing and validating technologies that will meet information and systems needs for future exploration missions.
Vision Integrating Strategies in Ophthalmology and Neurochemistry (VISION)
2011-02-01
in the above figure. We have already tested this virus in P23H Rhodopsin rat model of retinitis pigmentosa and found that it has a therapeutic...We have established three different mouse models of ocular injury with different injury-initiating mechanisms (i.e. optic nerve crush, retinal ...functionally and structurally rescue photoreceptor cells in rodent models of retinal degeneration. She brings expertise in gene therapy and in cellular
Software for Real-Time Analysis of Subsonic Test Shot Accuracy
2014-03-01
used the C++ programming language, the Open Source Computer Vision ( OpenCV ®) software library, and Microsoft Windows® Application Programming...video for comparison through OpenCV image analysis tools. Based on the comparison, the software then computed the coordinates of each shot relative to...DWB researchers wanted to use the Open Source Computer Vision ( OpenCV ) software library for capturing and analyzing frames of video. OpenCV contains
Why do seals have cones? Behavioural evidence for colour-blindness in harbour seals.
Scholtyssek, Christine; Kelber, Almut; Dehnhardt, Guido
2015-03-01
All seals and cetaceans have lost at least one of two ancestral cone classes and should therefore be colour-blind. Nevertheless, earlier studies showed that these marine mammals can discriminate colours and a colour vision mechanism has been proposed which contrasts signals from cones and rods. However, these earlier studies underestimated the brightness discrimination abilities of these animals, so that they could have discriminated colours using brightness only. Using a psychophysical discrimination experiment, we showed that a harbour seal can solve a colour discrimination task by means of brightness discrimination alone. Performing a series of experiments in which two harbour seals had to discriminate the brightness of colours, we also found strong evidence for purely scotopic (rod-based) vision at light levels that lead to mesopic (rod-cone-based) vision in other mammals. This finding speaks against rod-cone-based colour vision in harbour seals. To test for colour-blindness, we used a cognitive approach involving a harbour seal trained to use a concept of same and different. We tested this seal with pairs of isoluminant stimuli that were either same or different in colour. If the seal had perceived colour, it would have responded to colour differences between stimuli. However, the seal responded with "same", providing strong evidence for colour-blindness.
Integrated navigation, flight guidance, and synthetic vision system for low-level flight
NASA Astrophysics Data System (ADS)
Mehler, Felix E.
2000-06-01
Future military transport aircraft will require a new approach with respect to the avionics suite to fulfill an ever-changing variety of missions. The most demanding phases of these mission are typically the low level flight segments, including tactical terrain following/avoidance,payload drop and/or board autonomous landing at forward operating strips without ground-based infrastructure. As a consequence, individual components and systems must become more integrated to offer a higher degree of reliability, integrity, flexibility and autonomy over existing systems while reducing crew workload. The integration of digital terrain data not only introduces synthetic vision into the cockpit, but also enhances navigation and guidance capabilities. At DaimlerChrysler Aerospace AG Military Aircraft Division (Dasa-M), an integrated navigation, flight guidance and synthetic vision system, based on digital terrain data, has been developed to fulfill the requirements of the Future Transport Aircraft (FTA). The fusion of three independent navigation sensors provides a more reliable and precise solution to both the 4D-flight guidance and the display components, which is comprised of a Head-up and a Head-down Display with synthetic vision. This paper will present the system, its integration into the DLR's VFW 614 Advanced Technology Testing Aircraft System (ATTAS) and the results of the flight-test campaign.
Mallipatna, Ashwin; Vinekar, Anand; Jayadev, Chaitra; Dabir, Supriya; Sivakumar, Munsusamy; Krishnan, Narasimha; Mehta, Pooja; Berendschot, Tos; Yadav, Naresh Kumar
2015-07-01
Optical coherence tomography (OCT) is an important imaging tool assessing retinal architecture. In this article, we report a single centers experience of using handheld spectral domain (SD)-OCT in a pediatric population using the Envisu 2300 (Bioptigen Inc., Research Triangle Park, NC, USA). We studied SD-OCT images from 975 patients imaged from January 2011 to December 2014. The variety of cases that underwent an SD-OCT was analyzed. Cases examples from different case scenarios were selected to showcase unique examples of many diseases. Three hundred and sixty-eight infants (37.7%) were imaged for retinopathy of prematurity, 362 children (37.1%) underwent the test for evaluation of suboptimal vision or an unexplained vision loss, 126 children (12.9%) for evaluation of nystagmus or night blindness, 54 children (5.5%) for an intraocular tumor or a mass lesion such as retinoblastoma, and 65 children (6.7%) for other diseases of the pediatric retina. The unique findings in the retinal morphology seen with some of these diseases are discussed. The handheld SD-OCT is useful in the evaluation of the pediatric retinal diseases. The test is useful in the assessment of vision development in premature children, evaluation of unexplained vision loss and amblyopia, nystagmus and night blindness, and intraocular tumors (including retinoblastoma).
Hiramatsu, Chihiro; Melin, Amanda D; Allen, William L; Dubuc, Constance; Higham, James P
2017-06-14
Primate trichromatic colour vision has been hypothesized to be well tuned for detecting variation in facial coloration, which could be due to selection on either signal wavelengths or the sensitivities of the photoreceptors themselves. We provide one of the first empirical tests of this idea by asking whether, when compared with other visual systems, the information obtained through primate trichromatic vision confers an improved ability to detect the changes in facial colour that female macaque monkeys exhibit when they are proceptive. We presented pairs of digital images of faces of the same monkey to human observers and asked them to select the proceptive face. We tested images that simulated what would be seen by common catarrhine trichromatic vision, two additional trichromatic conditions and three dichromatic conditions. Performance under conditions of common catarrhine trichromacy, and trichromacy with narrowly separated LM cone pigments (common in female platyrrhines), was better than for evenly spaced trichromacy or for any of the dichromatic conditions. These results suggest that primate trichromatic colour vision confers excellent ability to detect meaningful variation in primate face colour. This is consistent with the hypothesis that social information detection has acted on either primate signal spectral reflectance or photoreceptor spectral tuning, or both. © 2017 The Authors.
Higham, James P.
2017-01-01
Primate trichromatic colour vision has been hypothesized to be well tuned for detecting variation in facial coloration, which could be due to selection on either signal wavelengths or the sensitivities of the photoreceptors themselves. We provide one of the first empirical tests of this idea by asking whether, when compared with other visual systems, the information obtained through primate trichromatic vision confers an improved ability to detect the changes in facial colour that female macaque monkeys exhibit when they are proceptive. We presented pairs of digital images of faces of the same monkey to human observers and asked them to select the proceptive face. We tested images that simulated what would be seen by common catarrhine trichromatic vision, two additional trichromatic conditions and three dichromatic conditions. Performance under conditions of common catarrhine trichromacy, and trichromacy with narrowly separated LM cone pigments (common in female platyrrhines), was better than for evenly spaced trichromacy or for any of the dichromatic conditions. These results suggest that primate trichromatic colour vision confers excellent ability to detect meaningful variation in primate face colour. This is consistent with the hypothesis that social information detection has acted on either primate signal spectral reflectance or photoreceptor spectral tuning, or both. PMID:28615496
Effects of body lean and visual information on the equilibrium maintenance during stance.
Duarte, Marcos; Zatsiorsky, Vladimir M
2002-09-01
Maintenance of equilibrium was tested in conditions when humans assume different leaning postures during upright standing. Subjects ( n=11) stood in 13 different body postures specified by visual center of pressure (COP) targets within their base of support (BOS). Different types of visual information were tested: continuous presentation of visual target, no vision after target presentation, and with simultaneous visual feedback of the COP. The following variables were used to describe the equilibrium maintenance: the mean of the COP position, the area of the ellipse covering the COP sway, and the resultant median frequency of the power spectral density of the COP displacement. The variability of the COP displacement, quantified by the COP area variable, increased when subjects occupied leaning postures, irrespective of the kind of visual information provided. This variability also increased when vision was removed in relation to when vision was present. Without vision, drifts in the COP data were observed which were larger for COP targets farther away from the neutral position. When COP feedback was given in addition to the visual target, the postural control system did not control stance better than in the condition with only visual information. These results indicate that the visual information is used by the postural control system at both short and long time scales.
Update on Clinical Trials in Dry Age-related Macular Degeneration
Taskintuna, Ibrahim; Elsayed, M. E. A. Abdalla; Schatz, Patrik
2016-01-01
This review article summarizes the most recent clinical trials for dry age-related macular degeneration (AMD), the most common cause of vision loss in the elderly in developed countries. A literature search through websites https://www.pubmed.org and https://www.clinicaltrials.gov/, both accessed no later than November 04, 2015, was performed. We identified three Phase III clinical trials that were completed over the recent 5 years Age-Related Eye Disease Study 2 (AREDS2), implantable miniature telescope and tandospirone, and several other trials targeting a variety of mechanisms including, oxidative stress, complement inhibition, visual cycle inhibition, retinal and choroidal blood flow, stem cells, gene therapy, and visual rehabilitation. To date, none of the biologically oriented therapies have resulted in improved vision. Vision improvement was reported with an implantable mini telescope. Stem cells therapy holds a potential for vision improvement. The AREDS2 formulas did not add any further reduced risk of progression to advanced AMD, compared to the original AREDS formula. Several recently discovered pathogenetic mechanisms in dry AMD have enabled development of new treatment strategies, and several of these have been tested in recent clinical trials and are currently being tested in ongoing trials. The rapid development and understanding of pathogenesis holds promise for the future. PMID:26957835
Parkhurst, Gregory D
2016-01-01
Purpose The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). Patients and methods This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Results Preoperative mean spherical equivalent was −6.10 D in the ICL group and −6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =−0.134, LASIK =−0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Conclusion Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction. PMID:27418804
Parkhurst, Gregory D
2016-01-01
The aim of this study was to evaluate and compare night vision and low-luminance contrast sensitivity (CS) in patients undergoing implantation of phakic collamer lenses or wavefront-optimized laser-assisted in situ keratomileusis (LASIK). This is a nonrandomized, prospective study, in which 48 military personnel were recruited. Rabin Super Vision Test was used to compare the visual acuity and CS of Visian implantable collamer lens (ICL) and LASIK groups under normal and low light conditions, using a filter for simulated vision through night vision goggles. Preoperative mean spherical equivalent was -6.10 D in the ICL group and -6.04 D in the LASIK group (P=0.863). Three months postoperatively, super vision acuity (SVa), super vision acuity with (low-luminance) goggles (SVaG), super vision contrast (SVc), and super vision contrast with (low luminance) goggles (SVcG) significantly improved in the ICL and LASIK groups (P<0.001). Mean improvement in SVaG at 3 months postoperatively was statistically significantly greater in the ICL group than in the LASIK group (mean change [logarithm of the minimum angle of resolution, LogMAR]: ICL =-0.134, LASIK =-0.085; P=0.032). Mean improvements in SVc and SVcG were also statistically significantly greater in the ICL group than in the LASIK group (SVc mean change [logarithm of the CS, LogCS]: ICL =0.356, LASIK =0.209; P=0.018 and SVcG mean change [LogCS]: ICL =0.390, LASIK =0.259; P=0.024). Mean improvement in SVa at 3 months was comparable in both groups (P=0.154). Simulated night vision improved with both ICL implantation and wavefront-optimized LASIK, but improvements were significantly greater with ICLs. These differences may be important in a military setting and may also affect satisfaction with civilian vision correction.
Gundersen, Kjell G; Potvin, Rick
2017-01-01
To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.
NASA Astrophysics Data System (ADS)
Lauinger, Norbert
1994-10-01
In photopic vision, two physical variables (luminance and wavelength) are transformed into three psychological variables (brightness, hue, and saturation). Following on from 3D grating optical explanations of aperture effects (Stiles-Crawford effects SCE I and II), all three variables can be explained via a single 3D chip effect. The 3D grating optical calculations are carried out using the classical von Laue equation and demonstrated using the example of two experimentally confirmed observations in human vision: saturation effects for monochromatic test lights between 485 and 510 nm in the SCE II and the fact that many test lights reverse their hue shift in the SCE II when changing from moderate to high luminances compared with that on changing from low to medium luminances. At the same time, information is obtained on the transition from the trichromatic color system in the retina to the opponent color system.
A low-cost machine vision system for the recognition and sorting of small parts
NASA Astrophysics Data System (ADS)
Barea, Gustavo; Surgenor, Brian W.; Chauhan, Vedang; Joshi, Keyur D.
2018-04-01
An automated machine vision-based system for the recognition and sorting of small parts was designed, assembled and tested. The system was developed to address a need to expose engineering students to the issues of machine vision and assembly automation technology, with readily available and relatively low-cost hardware and software. This paper outlines the design of the system and presents experimental performance results. Three different styles of plastic gears, together with three different styles of defective gears, were used to test the system. A pattern matching tool was used for part classification. Nine experiments were conducted to demonstrate the effects of changing various hardware and software parameters, including: conveyor speed, gear feed rate, classification, and identification score thresholds. It was found that the system could achieve a maximum system accuracy of 95% at a feed rate of 60 parts/min, for a given set of parameter settings. Future work will be looking at the effect of lighting.
Biologically Relevant Exposure Science for 21st Century Toxicity Testing
High visibility efforts in toxicity testing and computational toxicology including the recent NRC report, Toxicity Testing in the 21st Century: a Vision and Strategy (NRC, 2007), raise important research questions and opportunities for the field of exposure science. The authors ...
DOT National Transportation Integrated Search
1994-08-01
In his FY 92/93 Annual Program Guidance and Current Policy Statement, the Federal Air Surgeon requested continued investigation of new testing modalities, such as glare vision testing, as to their relevance to medical certification. Glare sensitivity...
... optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when it becomes suddenly ... may include: Color vision testing MRI of the brain , including special images of the optic nerve Visual acuity testing Visual field testing Examination of the ...
Test and Verification Approach for the NASA Constellation Program
NASA Technical Reports Server (NTRS)
Strong, Edward
2008-01-01
This viewgraph presentation is a test and verification approach for the NASA Constellation Program. The contents include: 1) The Vision for Space Exploration: Foundations for Exploration; 2) Constellation Program Fleet of Vehicles; 3) Exploration Roadmap; 4) Constellation Vehicle Approximate Size Comparison; 5) Ares I Elements; 6) Orion Elements; 7) Ares V Elements; 8) Lunar Lander; 9) Map of Constellation content across NASA; 10) CxP T&V Implementation; 11) Challenges in CxP T&V Program; 12) T&V Strategic Emphasis and Key Tenets; 13) CxP T&V Mission & Vision; 14) Constellation Program Organization; 15) Test and Evaluation Organization; 16) CxP Requirements Flowdown; 17) CxP Model Based Systems Engineering Approach; 18) CxP Verification Planning Documents; 19) Environmental Testing; 20) Scope of CxP Verification; 21) CxP Verification - General Process Flow; 22) Avionics and Software Integrated Testing Approach; 23) A-3 Test Stand; 24) Space Power Facility; 25) MEIT and FEIT; 26) Flight Element Integrated Test (FEIT); 27) Multi-Element Integrated Testing (MEIT); 28) Flight Test Driving Principles; and 29) Constellation s Integrated Flight Test Strategy Low Earth Orbit Servicing Capability.
Using Vision System Technologies for Offset Approaches in Low Visibility Operations
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Bailey, Randall E.; Ellis, Kyle K.
2015-01-01
Flight deck-based vision systems, such as Synthetic Vision Systems (SVS) and Enhanced Flight Vision Systems (EFVS), have the potential to provide additional margins of safety for aircrew performance and enable the implementation of operational improvements for low visibility surface, arrival, and departure operations in the terminal environment with equivalent efficiency to visual operations. Twelve air transport-rated crews participated in a motion-base simulation experiment to evaluate the use of SVS/EFVS in Next Generation Air Transportation System low visibility approach and landing operations at Chicago O'Hare airport. Three monochromatic, collimated head-up display (HUD) concepts (conventional HUD, SVS HUD, and EFVS HUD) and three instrument approach types (straight-in, 3-degree offset, 15-degree offset) were experimentally varied to test the efficacy of the SVS/EFVS HUD concepts for offset approach operations. The findings suggest making offset approaches in low visibility conditions with an EFVS HUD or SVS HUD appear feasible. Regardless of offset approach angle or HUD concept being flown, all approaches had comparable ILS tracking during the instrument segment and were within the lateral confines of the runway with acceptable sink rates during the visual segment of the approach. Keywords: Enhanced Flight Vision Systems; Synthetic Vision Systems; Head-up Display; NextGen
Development and validation of an instrument to assess job satisfaction in eye-care personnel.
Paudel, Prakash; Cronjé, Sonja; O'Connor, Patricia M; Khadka, Jyoti; Rao, Gullapalli N; Holden, Brien A
2017-11-01
The aim was to develop and validate an instrument to measure job satisfaction in eye-care personnel and assess the job satisfaction of one-year trained vision technicians in India. A pilot instrument for assessing job satisfaction was developed, based on a literature review and input from a public health expert panel. Rasch analysis was used to assess psychometric properties and to undertake an iterative item reduction. The instrument was then administered to vision technicians in vision centres of Andhra Pradesh in India. Associations between vision technicians' job satisfaction and factors such as age, gender and experience were analysed using t-test and one-way analysis of variance. Rasch analysis confirmed that the 15-item job satisfaction in eye-care personnel (JSEP) was a unidimensional instrument with good fit statistics, measurement precisions and absence of differential item functioning. Overall, vision technicians reported high rates of job satisfaction (0.46 logits). Age, gender and experience were not associated with high job satisfaction score. Item score analysis showed non-financial incentives, salary and workload were the most important determinants of job satisfaction. The 15-item JSEP instrument is a valid instrument for assessing job satisfaction among eye-care personnel. Overall, vision technicians in India demonstrated high rates of job satisfaction. © 2016 Optometry Australia.
Personal vision: enhancing work engagement and the retention of women in the engineering profession.
Buse, Kathleen R; Bilimoria, Diana
2014-01-01
This study examines how personal vision enhances work engagement and the retention of women in the engineering profession. Using a mixed method approach to understand the factors related to the retention of women in the engineering profession, we first interviewed women who persisted and women who opted out of the profession (Buse and Bilimoria, 2014). In these rich stories, we found that women who persisted had a personal vision that included their profession, and that this personal vision enabled them to overcome the bias, barriers and discrimination in the engineering workplace. To validate this finding on a larger population, we developed a scale to measure one's personal vision conceptualized as the ideal self (Boyatzis and Akrivou, 2006). The measure was tested in a pilot study and then used in a study of 495 women with engineering degrees. The findings validate that the ideal self is comprised of self-efficacy, hope, optimism and core identity. For these women, the ideal self directly impacts work engagement and work engagement directly impacts career commitment to engineering. The findings add to extant theory related to the role of personal vision and intentional change theory. From a practical perspective, these findings will aid efforts to retain women in engineering and other STEM professions.
Personal vision: enhancing work engagement and the retention of women in the engineering profession
Buse, Kathleen R.; Bilimoria, Diana
2014-01-01
This study examines how personal vision enhances work engagement and the retention of women in the engineering profession. Using a mixed method approach to understand the factors related to the retention of women in the engineering profession, we first interviewed women who persisted and women who opted out of the profession (Buse and Bilimoria, 2014). In these rich stories, we found that women who persisted had a personal vision that included their profession, and that this personal vision enabled them to overcome the bias, barriers and discrimination in the engineering workplace. To validate this finding on a larger population, we developed a scale to measure one's personal vision conceptualized as the ideal self (Boyatzis and Akrivou, 2006). The measure was tested in a pilot study and then used in a study of 495 women with engineering degrees. The findings validate that the ideal self is comprised of self-efficacy, hope, optimism and core identity. For these women, the ideal self directly impacts work engagement and work engagement directly impacts career commitment to engineering. The findings add to extant theory related to the role of personal vision and intentional change theory. From a practical perspective, these findings will aid efforts to retain women in engineering and other STEM professions. PMID:25538652
Pongrácz, Péter; Ujvári, Vera; Faragó, Tamás; Miklósi, Ádám; Péter, András
2017-07-01
The visual sense of dogs is in many aspects different than that of humans. Unfortunately, authors do not explicitly take into consideration dog-human differences in visual perception when designing their experiments. With an image manipulation program we altered stationary images, according to the present knowledge about dog-vision. Besides the effect of dogs' dichromatic vision, the software shows the effect of the lower visual acuity and brightness discrimination, too. Fifty adult humans were tested with pictures showing a female experimenter pointing, gazing or glancing to the left or right side. Half of the pictures were shown after they were altered to a setting that approximated dog vision. Participants had difficulty to find out the direction of glancing when the pictures were in dog-vision mode. Glances in dog-vision setting were followed less correctly and with a slower response time than other cues. Our results are the first that show the visual performance of humans under circumstances that model how dogs' weaker vision would affect their responses in an ethological experiment. We urge researchers to take into consideration the differences between perceptual abilities of dogs and humans, by developing visual stimuli that fit more appropriately to dogs' visual capabilities. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Synthetic Vision EGE Flight Test
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J.; Kramer, Lynda J.; Comstock, J. Raymond; Bailey, Randall E.; Hughes, Monica F.; Parrish, Russell V.
2002-01-01
NASA Langley Research Center conducted flight tests at the Eagle County, Colorado airport to evaluate synthetic vision concepts. Three display concepts (size 'A' head-down, size 'X' head-down, and head-up displays) and two texture concepts (photo, generic) were assessed for situation awareness and flight technical error / performance while making approaches to Runway 25 and Runway 07 and simulated engine-out Cottonwood 2 and KREMM departures. The results of the study confirm the retrofit capability of the HUD and Size 'A' SVS concepts to significantly improve situation awareness and performance over current EFIS glass and non-glass instruments for difficult approaches in terrain-challenged environments.
Improvement of individual camouflage through background choice in ground-nesting birds.
Stevens, Martin; Troscianko, Jolyon; Wilson-Aggarwal, Jared K; Spottiswoode, Claire N
2017-09-01
Animal camouflage is a longstanding example of adaptation. Much research has tested how camouflage prevents detection and recognition, largely focusing on changes to an animal's own appearance over evolution. However, animals could also substantially alter their camouflage by behaviourally choosing appropriate substrates. Recent studies suggest that individuals from several animal taxa could select backgrounds or positions to improve concealment. Here, we test whether individual wild animals choose backgrounds in complex environments, and whether this improves camouflage against predator vision. We studied nest site selection by nine species of ground-nesting birds (nightjars, plovers and coursers) in Zambia, and used image analysis and vision modeling to quantify egg and plumage camouflage to predator vision. Individual birds chose backgrounds that enhanced their camouflage, being better matched to their chosen backgrounds than to other potential backgrounds with respect to multiple aspects of camouflage. This occurred at all three spatial scales tested (a few cm and five meters from the nest, and compared to other sites chosen by conspecifics), and was the case for the eggs of all bird groups studied, and for adult nightjar plumage. Thus, individual wild animals improve their camouflage through active background choice, with choices highly refined across multiple spatial scales.
Improvement of individual camouflage through background choice in ground-nesting birds
Stevens, Martin; Troscianko, Jolyon; Wilson-Aggarwal, Jared K.; Spottiswoode, Claire N.
2017-01-01
Animal camouflage is a longstanding example of adaptation. Much research has tested how camouflage prevents detection and recognition, largely focusing on changes to an animal's own appearance over evolution. However, animals could also substantially alter their camouflage by behaviourally choosing appropriate substrates. Recent studies suggest that individuals from several animal taxa could select backgrounds or positions to improve concealment. Here, we test whether individual wild animals choose backgrounds in complex environments, and whether this improves camouflage against predator vision. We studied nest site selection by nine species of ground-nesting birds (nightjars, plovers and coursers) in Zambia, and used image analysis and vision modeling to quantify egg and plumage camouflage to predator vision. Individual birds chose backgrounds that enhanced their camouflage, being better matched to their chosen backgrounds than to other potential backgrounds with respect to multiple aspects of camouflage. This occurred at all three spatial scales tested (a few cm and five meters from the nest, and compared to other sites chosen by conspecifics), and was the case for the eggs of all bird groups studied, and for adult nightjar plumage. Thus, individual wild animals improve their camouflage through active background choice, with choices highly refined across multiple spatial scales. PMID:28890937
Low Cost Night Vision System for Intruder Detection
NASA Astrophysics Data System (ADS)
Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.
2016-02-01
The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.
Metal surface corrosion grade estimation from single image
NASA Astrophysics Data System (ADS)
Chen, Yijun; Qi, Lin; Sun, Huyuan; Fan, Hao; Dong, Junyu
2018-04-01
Metal corrosion can cause many problems, how to quickly and effectively assess the grade of metal corrosion and timely remediation is a very important issue. Typically, this is done by trained surveyors at great cost. Assisting them in the inspection process by computer vision and artificial intelligence would decrease the inspection cost. In this paper, we propose a dataset of metal surface correction used for computer vision detection and present a comparison between standard computer vision techniques by using OpenCV and deep learning method for automatic metal surface corrosion grade estimation from single image on this dataset. The test has been performed by classifying images and calculating the accuracy for the two different approaches.
Night vision imaging system design, integration and verification in spacecraft vacuum thermal test
NASA Astrophysics Data System (ADS)
Shang, Yonghong; Wang, Jing; Gong, Zhe; Li, Xiyuan; Pei, Yifei; Bai, Tingzhu; Zhen, Haijing
2015-08-01
The purposes of spacecraft vacuum thermal test are to characterize the thermal control systems of the spacecraft and its component in its cruise configuration and to allow for early retirement of risks associated with mission-specific and novel thermal designs. The orbit heat flux is simulating by infrared lamp, infrared cage or electric heater. As infrared cage and electric heater do not emit visible light, or infrared lamp just emits limited visible light test, ordinary camera could not operate due to low luminous density in test. Moreover, some special instruments such as satellite-borne infrared sensors are sensitive to visible light and it couldn't compensate light during test. For improving the ability of fine monitoring on spacecraft and exhibition of test progress in condition of ultra-low luminous density, night vision imaging system is designed and integrated by BISEE. System is consist of high-gain image intensifier ICCD camera, assistant luminance system, glare protect system, thermal control system and computer control system. The multi-frame accumulation target detect technology is adopted for high quality image recognition in captive test. Optical system, mechanical system and electrical system are designed and integrated highly adaptable to vacuum environment. Molybdenum/Polyimide thin film electrical heater controls the temperature of ICCD camera. The results of performance validation test shown that system could operate under vacuum thermal environment of 1.33×10-3Pa vacuum degree and 100K shroud temperature in the space environment simulator, and its working temperature is maintains at 5° during two-day test. The night vision imaging system could obtain video quality of 60lp/mm resolving power.
Effect of cholesterol deposition on bacterial adhesion to contact lenses.
Babaei Omali, Negar; Zhu, Hua; Zhao, Zhenjun; Ozkan, Jerome; Xu, Banglao; Borazjani, Roya; Willcox, Mark D P
2011-08-01
To examine the effect of cholesterol on the adhesion of bacteria to silicone hydrogel contact lenses. Contact lenses, collected from subjects wearing Acuvue Oasys or PureVision lenses, were extracted in chloroform:methanol (1:1, v/v) and amount of cholesterol was estimated by thin-layer chromatography. Unworn lenses were soaked in cholesterol, and the numbers of Pseudomonas aeruginosa strains or Staphylococcus aureus strains that adhered to the lenses were measured. Cholesterol was tested for effects on bacterial growth by incubating bacteria in medium containing cholesterol. From ex vivo PureVision lenses, 3.4 ± 0.3 μg/lens cholesterol was recovered, and from Acuvue Oasys lenses, 2.4 ± 0.2 to 1.0 ± 0.1 μg/lens cholesterol was extracted. Cholesterol did not alter the total or viable adhesion of any strain of P. aeruginosa or S. aureus (p > 0.05). However, worn PureVision lenses reduced the numbers of viable cells of P. aeruginosa (5.8 ± 0.4 log units) compared with unworn lenses (6.4 ± 0.2 log units, p = 0.001). Similarly, there were fewer numbers of S. aureus 031 adherent to worn PureVision (3.05 ± 0.8 log units) compared with unworn PureVision (4.6 ± 0.3 log units, p = 0.0001). Worn Acuvue Oasys lenses did not affect bacterial adhesion. Cholesterol showed no effect on the growth of any test strain. Although cholesterol has been shown to adsorb to contact lenses during wear, this lipid does not appear to modulate bacterial adhesion to a lens surface.
Suzukamo, Yoshimi; Oshika, Tetsuro; Yuzawa, Mitsuko; Tokuda, Yoshihiro; Tomidokoro, Atsuo; Oki, Kotaro; Mangione, Carol M; Green, Joseph; Fukuhara, Shunichi
2005-10-26
The importance of evaluating the outcomes of health care from the standpoint of the patient is now widely recognized. The purpose of this study is to develop and test a Japanese version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). A Japanese version was developed with a previously standardized method. The questionnaire and optional items were completed by 245 patients with cataracts, glaucoma, or age-related macular degeneration, by 110 others before and after cataract surgery, and by a reference group (n = 31). We computed rates of missing data, measured reproducibility and internal consistency reliability, and tested for convergent and discriminant validity, concurrent validity, known-groups validity, factor structure, and responsiveness to change. Based on information from the participants, some items were changed to 2-step items (asking if an activity was done, and if it was done, then asking how difficult it was). The near-vision and distance-vision subscales each had 1 item that was endorsed by very few participants, so these items were replaced with items that were optional in the English version. For example, more than 60% of participants did not drive, so the driving question was excluded. Reliability and validity were adequate for all subscales except driving, ocular pain, color vision, and peripheral vision. With cataract surgery, most scores improved by at least 20 points. With minor modifications from the English version, the Japanese NEI VFQ-25 can give reliable, valid, responsive data on vision-related quality of life, for group-level comparisons or for tracking therapeutic outcomes.
Ma, Jin; Li, Honghui; Ding, Xiaohu; Tanumiharjo, Silvia; Lu, Lin
2017-01-01
Purpose To evaluate the efficacy of a combined macular buckle under direct vision and 23-gauge pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling in refractory macular hole retinal detachment (MHRD) with extreme high axial myopia. Design Prospective, randomised controlled study. Participants The study included 98 eyes of 98 patients of MHRD with extreme high axial (>30 mm) myopia. Intervention Patients were randomly assigned to undergo PPV with ILM peeling (group 1, n=52) or PPV with ILM peeling combined with macular buckle under direct vision (group 2, n=46). Main outcome measures Complete ocular examination included best-corrected visual acuity (BCVA) (LogMAR), applanation tonometry, optical biometry, slit-lamp biomicroscopy, colour fundus photography, ultrasound examination and optical coherence tomography at baseline and every follow-up visit. Results Initial retinal reattachment rate was significantly higher in group 2 than in group 1 at 12-month postoperatively (χ2 test, p=0.020). Macular hole closure rate in group 2 was significantly higher than that in group 1 at 3, 12, 18 and 24 months postoperatively (Fisher's exact test, p<0.05). In initial retinal reattachment cases, the mean BCVA decreased significantly in group 2 than in group 1 at 3 months postoperatively (Wilcoxon matched pairs signed rank test, p=0.036), and had increased significantly in group 2 than in group 1 since 6 months postoperatively (Wilcoxon matched pairs signed rank test, p<0.05). Mean axial lengths in group 2 were significantly shorter than that of group 1 at each follow-up time point (Wilcoxon matched pairs signed rank test, p<0.05). Conclusions Combined macular buckle under direct vision and PPV with ILM peeling is more effective in treatment of MHRD with extreme high axial (>30 mm) myopia. PMID:28292775
Evidence for the need for vision screening of school children in Turkey.
Azizoğlu, Serap; Crewther, Sheila G; Şerefhan, Funda; Barutchu, Ayla; Göker, Sinan; Junghans, Barbara M
2017-12-02
In many countries, access to general health and eye care is related to an individual's socioeconomic status (SES). We aimed to examine the prevalence of oculo-visual disorders in children in Istanbul Turkey, drawn from schools at SES extremes but geographically nearby. Three school-based vision screenings (presenting distance visual acuity, cover test, eye assessment history, colour vision, gross stereopsis and non-cycloplegic autorefraction) were conducted on 81% of a potential 1014 primary-school children aged 4-10 years from two private (high SES) schools and a nearby government (low SES) school in central Istanbul. Prevalence of refractive errors and school-based differences were analysed using parametric statistics (ANOVA). The remaining oculo-visual aspects were compared using non-parametric tests. Of the 823 children with mean age 6.7 ± 2.2 years, approximately 10% were referred for a full eye examination (8.2% and 16.3% of private/government schools respectively). Vision had not been previously examined in nearly 22% of private school children and 65% of government school children. Of all children, 94.5% were able to accurately identify the 6/9.5 [LogMAR 0.2] line of letters/shapes with each eye and 86.6% the 6/6 line [LogMAR 0], while 7.9% presented wearing spectacles, 3.8% had impaired colour vision, 1.5% had grossly impaired stereo-vision, 1.5% exhibited strabismus, 1.8% were suspected to have amblyopia and 0.5% had reduced acuity of likely organic origin. Of the 804 without strabismus, amblyopia or organic conditions, 6.0% were myopic ≤ - 0.50DS, 0.6% hyperopic ≥ + 2.00DS, 7.7% astigmatic ≥1.00 DC and 6.2% anisometropic ≥1.00DS. The results highlight the need for general vision screenings for all children prior to school entry given the varied and different pattern of visual problems associated with lifestyle differences in two populations raised in the same urban locale but drawn from different socioeconomic backgrounds.
What Do Patients With Glaucoma See? Visual Symptoms Reported by Patients With Glaucoma
Hu, Cindy X.; Zangalli, Camila; Hsieh, Michael; Gupta, Lalita; Williams, Alice L.; Richman, Jesse
2014-01-01
Abstract: Background: Vision loss from glaucoma has traditionally been described as loss of “peripheral vision.” In this prospective study, we aimed to improve our clinical understanding of the visual symptoms caused by glaucoma by asking patients specific detailed questions about how they see. Methods: Patients who were clinically diagnosed with various types and stages of glaucoma were included. All had a comprehensive ocular examination, including Octopus visual field testing. Patients were excluded if they had other ocular conditions that affected their vision, including cornea, lens or retina pathologies. Patients responded to an oral questionnaire about their visual symptoms. We investigated the visual symptoms described by patients with glaucoma and correlated the severity of visual field loss with visual symptoms reported. Results: Ninety-nine patients completed the questionnaire. Most patients (76%) were diagnosed with primary open-angle glaucoma. The most common symptoms reported by all patients, including patients with early or moderate glaucoma, were needing more light and blurry vision. Patients with a greater amount of field loss (Octopus mean defect >+9.4 dB) were more likely to report difficulty seeing objects to one or both sides, as if looking through dirty glasses and trouble differentiating boundaries and colors. Conclusions: Vision loss in patients with glaucoma is not as simple as the traditional view of loss of peripheral vision. Needing more light and blurry vision were the most common symptoms reported by patients with glaucoma. PMID:24992392
Quality grading of Atlantic salmon (Salmo salar) by computer vision.
Misimi, E; Erikson, U; Skavhaug, A
2008-06-01
In this study, we present a promising method of computer vision-based quality grading of whole Atlantic salmon (Salmo salar). Using computer vision, it was possible to differentiate among different quality grades of Atlantic salmon based on the external geometrical information contained in the fish images. Initially, before the image acquisition, the fish were subjectively graded and labeled into grading classes by a qualified human inspector in the processing plant. Prior to classification, the salmon images were segmented into binary images, and then feature extraction was performed on the geometrical parameters of the fish from the grading classes. The classification algorithm was a threshold-based classifier, which was designed using linear discriminant analysis. The performance of the classifier was tested by using the leave-one-out cross-validation method, and the classification results showed a good agreement between the classification done by human inspectors and by the computer vision. The computer vision-based method classified correctly 90% of the salmon from the data set as compared with the classification by human inspector. Overall, it was shown that computer vision can be used as a powerful tool to grade Atlantic salmon into quality grades in a fast and nondestructive manner by a relatively simple classifier algorithm. The low cost of implementation of today's advanced computer vision solutions makes this method feasible for industrial purposes in fish plants as it can replace manual labor, on which grading tasks still rely.
NASA Technical Reports Server (NTRS)
Shelton, Kevin J.; Kramer, Lynda J.; Ellis,Kyle K.; Rehfeld, Sherri A.
2012-01-01
The Synthetic and Enhanced Vision Systems for NextGen (SEVS) simulation and flight tests are jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA). The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SEVS operational and system-level performance capabilities. Nine test flights (38 flight hours) were conducted over the summer and fall of 2011. The evaluations were flown in Gulfstream.s G450 flight test aircraft outfitted with the SEVS technology under very low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 ft to 2400 ft visibility) into various airports from Louisiana to Maine. In-situ flight performance and subjective workload and acceptability data were collected in collaboration with ground simulation studies at LaRC.s Research Flight Deck simulator.
Agaba, Morris; Cavener, Douglas R.
2017-01-01
Background The capacity of visually oriented species to perceive and respond to visual signal is integral to their evolutionary success. Giraffes are closely related to okapi, but the two species have broad range of phenotypic differences including their visual capacities. Vision studies rank giraffe’s visual acuity higher than all other artiodactyls despite sharing similar vision ecological determinants with many of them. The extent to which the giraffe’s unique visual capacity and its difference with okapi is reflected by changes in their vision genes is not understood. Methods The recent availability of giraffe and okapi genomes provided opportunity to identify giraffe and okapi vision genes. Multiple strategies were employed to identify thirty-six candidate mammalian vision genes in giraffe and okapi genomes. Quantification of selection pressure was performed by a combination of branch-site tests of positive selection and clade models of selection divergence through comparing giraffe and okapi vision genes and orthologous sequences from other mammals. Results Signatures of selection were identified in key genes that could potentially underlie giraffe and okapi visual adaptations. Importantly, some genes that contribute to optical transparency of the eye and those that are critical in light signaling pathway were found to show signatures of adaptive evolution or selection divergence. Comparison between giraffe and other ruminants identifies significant selection divergence in CRYAA and OPN1LW. Significant selection divergence was identified in SAG while positive selection was detected in LUM when okapi is compared with ruminants and other mammals. Sequence analysis of OPN1LW showed that at least one of the sites known to affect spectral sensitivity of the red pigment is uniquely divergent between giraffe and other ruminants. Discussion By taking a systemic approach to gene function in vision, the results provide the first molecular clues associated with giraffe and okapi vision adaptations. At least some of the genes that exhibit signature of selection may reflect adaptive response to differences in giraffe and okapi habitat. We hypothesize that requirement for long distance vision associated with predation and communication with conspecifics likely played an important role in the adaptive pressure on giraffe vision genes. PMID:28396824
Ishengoma, Edson; Agaba, Morris; Cavener, Douglas R
2017-01-01
The capacity of visually oriented species to perceive and respond to visual signal is integral to their evolutionary success. Giraffes are closely related to okapi, but the two species have broad range of phenotypic differences including their visual capacities. Vision studies rank giraffe's visual acuity higher than all other artiodactyls despite sharing similar vision ecological determinants with many of them. The extent to which the giraffe's unique visual capacity and its difference with okapi is reflected by changes in their vision genes is not understood. The recent availability of giraffe and okapi genomes provided opportunity to identify giraffe and okapi vision genes. Multiple strategies were employed to identify thirty-six candidate mammalian vision genes in giraffe and okapi genomes. Quantification of selection pressure was performed by a combination of branch-site tests of positive selection and clade models of selection divergence through comparing giraffe and okapi vision genes and orthologous sequences from other mammals. Signatures of selection were identified in key genes that could potentially underlie giraffe and okapi visual adaptations. Importantly, some genes that contribute to optical transparency of the eye and those that are critical in light signaling pathway were found to show signatures of adaptive evolution or selection divergence. Comparison between giraffe and other ruminants identifies significant selection divergence in CRYAA and OPN1LW . Significant selection divergence was identified in SAG while positive selection was detected in LUM when okapi is compared with ruminants and other mammals. Sequence analysis of OPN1LW showed that at least one of the sites known to affect spectral sensitivity of the red pigment is uniquely divergent between giraffe and other ruminants. By taking a systemic approach to gene function in vision, the results provide the first molecular clues associated with giraffe and okapi vision adaptations. At least some of the genes that exhibit signature of selection may reflect adaptive response to differences in giraffe and okapi habitat. We hypothesize that requirement for long distance vision associated with predation and communication with conspecifics likely played an important role in the adaptive pressure on giraffe vision genes.
[Are Visual Field Defects Reversible? - Visual Rehabilitation with Brains].
Sabel, B A
2017-02-01
Visual field defects are considered irreversible because the retina and optic nerve do not regenerate. Nevertheless, there is some potential for recovery of the visual fields. This can be accomplished by the brain, which analyses and interprets visual information and is able to amplify residual signals through neuroplasticity. Neuroplasticity refers to the ability of the brain to change its own functional architecture by modulating synaptic efficacy. This is actually the neurobiological basis of normal learning. Plasticity is maintained throughout life and can be induced by repetitively stimulating (training) brain circuits. The question now arises as to how plasticity can be utilised to activate residual vision for the treatment of visual field loss. Just as in neurorehabilitation, visual field defects can be modulated by post-lesion plasticity to improve vision in glaucoma, diabetic retinopathy or optic neuropathy. Because almost all patients have some residual vision, the goal is to strengthen residual capacities by enhancing synaptic efficacy. New treatment paradigms have been tested in clinical studies, including vision restoration training and non-invasive alternating current stimulation. While vision training is a behavioural task to selectively stimulate "relative defects" with daily vision exercises for the duration of 6 months, treatment with alternating current stimulation (30 min. daily for 10 days) activates and synchronises the entire retina and brain. Though full restoration of vision is not possible, such treatments improve vision, both subjectively and objectively. This includes visual field enlargements, improved acuity and reaction time, improved orientation and vision related quality of life. About 70 % of the patients respond to the therapies and there are no serious adverse events. Physiological studies of the effect of alternating current stimulation using EEG and fMRI reveal massive local and global changes in the brain. These include local activation of the visual cortex and global reorganisation of neuronal brain networks. Because modulation of neuroplasticity can strengthen residual vision, the brain deserves a better reputation in ophthalmology for its role in visual rehabilitation. For patients, there is now more light at the end of the tunnel, because vision loss in some areas of the visual field defect is indeed reversible. Georg Thieme Verlag KG Stuttgart · New York.
da Costa, Marcelo Fernandes; Júnior, Augusto Paranhos; Lottenberg, Claudio Luiz; Castro, Leonardo Cunha; Ventura, Dora Fix
2017-12-01
The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.
Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos
2009-01-01
To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 +/- 0.6 years). Color vision defects were studied using a special computer program for Farnsworth-Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30-2. Both tests were repeated every six months. In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 +/- 31.79) and OH eyes (75.51 +/- 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was -20.62 +/- 2.75 (t value 9.08, p < 0.001) while in OH eyes was -2.11 +/- 4.36 (t value 1.1, p = 0.276). Pearson's coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields.
3D vision system for intelligent milking robot automation
NASA Astrophysics Data System (ADS)
Akhloufi, M. A.
2013-12-01
In a milking robot, the correct localization and positioning of milking teat cups is of very high importance. The milking robots technology has not changed since a decade and is based primarily on laser profiles for teats approximate positions estimation. This technology has reached its limit and does not allow optimal positioning of the milking cups. Also, in the presence of occlusions, the milking robot fails to milk the cow. These problems, have economic consequences for producers and animal health (e.g. development of mastitis). To overcome the limitations of current robots, we have developed a new system based on 3D vision, capable of efficiently positioning the milking cups. A prototype of an intelligent robot system based on 3D vision for real-time positioning of a milking robot has been built and tested under various conditions on a synthetic udder model (in static and moving scenarios). Experimental tests, were performed using 3D Time-Of-Flight (TOF) and RGBD cameras. The proposed algorithms permit the online segmentation of teats by combing 2D and 3D visual information. The obtained results permit the teat 3D position computation. This information is then sent to the milking robot for teat cups positioning. The vision system has a real-time performance and monitors the optimal positioning of the cups even in the presence of motion. The obtained results, with both TOF and RGBD cameras, show the good performance of the proposed system. The best performance was obtained with RGBD cameras. This latter technology will be used in future real life experimental tests.
The Effects of Modafinil and OTC Stimulants on Physical and Cognitive Performance
2016-03-07
least 7 hours per night were either rescheduled until the sleep requirements were met or dropped from the study. 2.1.3 Vision testing. Vision...the study. Those potential participants who did not sleep at least 7 hours per night were either rescheduled until the sleep requirements were met...could not reschedule another time to return. Therefore, 19 individuals completed the study. One participant’s data indicated poor compliance with
2011-05-01
Medical Institute’s publications Web site: www.faa.gov/library/reports/medical/oamtechreports i Technical Report Documentation Page 1. Report No. 2...Study One provided evidence of the reliability of the subtests, established performance norms for subjects with normal color vision ( NCV ) on each...Two provided evidence of the reliability of second operational ATCOV subtests, established performance norms for NCV subjects on each subtest
2010-01-01
télévision à bas niveau de lumière /TV BNL / [NASG] LMCC LOCE mobile communications centre [NASG] centre de communications mobile du LOCE [NASG...AC/224] équipe de soutien technique [STANAG 4607] T-12 AAP-15(2010) TV BNL TTBT télévision à bas niveau de lumière Threshold Test-Ban
Effects of Learning on Performance When Computerized Dynamic Posturography Assessments Are Repeated
NASA Technical Reports Server (NTRS)
Taylor, Laura C.; Paloski, William H.; Wood, Scott J.
2008-01-01
Background: Computerized dynamic posturography is widely used to measure balance control performance. Clinically, performance is assessed by comparing individual data against standards obtained from a normative population. When performing repeated assessments to track performance changes, one must be concerned with the influence of learning effects. Subjects do not have the opportunity to practice before the first session, and often a second session is not performed prior to an experiment. Thus, the objective of this activity was to examine learning effects on balance control performance. We hypothesize that subjects will perform better on the second session when compared to the first, and that the difference will be greater for more difficult conditions. Methods: Data were collected from 204 subjects using the NeuroCom Equitest system during quiet stance with arms crossed at the chest on up to two sessions. All subjects performed standard sensory organization tests (SOTs) including 1) normal vision, fixed support; 2) absent vision, fixed support; 3) sway-referenced vision, fixed support; 4) normal vision, swayreferenced support; 5) absent vision, sway-referenced support; and 6) sway-referenced vision, sway-referenced support. 120 of these subjects performed modified sensory organization tests (mSOTs 2 and 5) which included static (20 back) and dynamic (20, 0.33Hz) head tilts. Median equilibrium scores (mEQ) were calculated from peak-to-peak anterior-posterior sway across trials. Data collected on the first session were then compared with the second to examine learning effect. Results: There were no differences in mEQ scores between the first and second sessions for SOTs 1, 2, and 4, while mEQ scores were higher for the second session when compared to the first for SOTs 3, 5, and 6 and for all mSOTs. Discussion: An additional familiarization session or practice trials prior to the first session may be necessary for more challenging SOT and mSOT conditions to minimize learning effect.
McGilton, Katherine S; Höbler, Fiona; Campos, Jennifer; Dupuis, Kate; Labreche, Tammy; Guthrie, Dawn M; Jarry, Jonathan; Singh, Gurjit; Wittich, Walter
2016-01-01
Introduction Hearing and vision loss among long-term care (LTC) residents with dementia frequently goes unnoticed and untreated. Despite negative consequences for these residents, there is little information available about their sensory abilities and care assessments and practices seldom take these abilities or accessibility needs into account. Without adequate knowledge regarding such sensory loss, it is difficult for LTC staff to determine the level of an individual's residual basic competence for communication and independent functioning. We will conduct a scoping review to identify the screening measures used in research and clinical contexts that test hearing and vision in adults aged over 65 years with dementia, aiming to: (1) provide an overview of hearing and vision screening in older adults with dementia; and (2) evaluate the sensibility of the screening tools. Methods and analysis This scoping review will be conducted using the framework by Arksey and O'Malley and furthered by methodological enhancements from cited researchers. We will conduct electronic database searches in CENTRAL, CINAHL, EMBASE, MEDLINE and PsycINFO. We will also carry out a ‘grey literature’ search for studies or materials not formally published, both online and through interview discussions with healthcare professionals and research clinicians working in the field. Our aim is to find new and existing hearing and vision screening measures used in research and by clinical professionals of optometry and audiology. Abstracts will be independently reviewed twice for acceptance by a multidisciplinary team of researchers and research clinicians. Ethics and dissemination This review will inform health professionals working with this growing population. With the review findings, we aim to develop a toolkit and an algorithmic process to select the most appropriate hearing and vision screening assessments for LTC residents with dementia that will facilitate accurate testing and can inform care planning, thereby improving residents’ quality of life. PMID:27466242
Bruce, Alison; Fairley, Lesley; Chambers, Bette; Wright, John; Sheldon, Trevor A
2016-02-16
To estimate the prevalence of poor vision in children aged 4-5 years and determine the impact of visual acuity on literacy. Cross-sectional study linking clinical, epidemiological and education data. Schools located in the city of Bradford, UK. Prevalence was determined for 11,186 children participating in the Bradford school vision screening programme. Data linkage was undertaken for 5836 Born in Bradford (BiB) birth cohort study children participating both in the Bradford vision screening programme and the BiB Starting Schools Programme. 2025 children had complete data and were included in the multivariable analyses. Visual acuity was measured using a logMAR Crowded Test (higher scores=poorer visual acuity). Literacy measured by Woodcock Reading Mastery Tests-Revised (WRMT-R) subtest: letter identification (standardised). The mean (SD) presenting visual acuity was 0.14 (0.09) logMAR (range 0.0-1.0). 9% of children had a presenting visual acuity worse than 0.2logMAR (failed vision screening), 4% worse than 0.3logMAR (poor visual acuity) and 2% worse than 0.4logMAR (visually impaired). Unadjusted analysis showed that the literacy score was associated with presenting visual acuity, reducing by 2.4 points for every 1 line (0.10logMAR) reduction in vision (95% CI -3.0 to -1.9). The association of presenting visual acuity with the literacy score remained significant after adjustment for demographic and socioeconomic factors reducing by 1.7 points (95% CI -2.2 to -1.1) for every 1 line reduction in vision. Prevalence of decreased visual acuity was high compared with other population-based studies. Decreased visual acuity at school entry is associated with reduced literacy. This may have important implications for the children's future educational, health and social outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/