Sample records for visual detection limit

  1. Detection Progress of Selected Drugs in TLC

    PubMed Central

    Pyka, Alina

    2014-01-01

    This entry describes applications of known indicators and dyes as new visualizing reagents and various visualizing systems as well as photocatalytic reactions and bioautography method for the detection of bioactive compounds including drugs and compounds isolated from herbal extracts. Broadening index, detection index, characteristics of densitometric band, modified contrast index, limit of detection, densitometric visualizing index, and linearity range of detected compounds were used for the evaluation of visualizing effects of applied visualizing reagents. It was shown that visualizing effect depends on the chemical structure of the visualizing reagent, the structure of the substance detected, and the chromatographic adsorbent applied. The usefulness of densitometry to direct detection of some drugs was also shown. Quoted papers indicate the detection progress of selected drugs investigated by thin-layer chromatography (TLC). PMID:24551853

  2. Qualitative Contrast between Knowledge-Limited Mixed-State and Variable-Resources Models of Visual Change Detection

    ERIC Educational Resources Information Center

    Nosofsky, Robert M.; Donkin, Chris

    2016-01-01

    We report an experiment designed to provide a qualitative contrast between knowledge-limited versions of mixed-state and variable-resources (VR) models of visual change detection. The key data pattern is that observers often respond "same" on big-change trials, while simultaneously being able to discriminate between same and small-change…

  3. Surprise-Induced Blindness: A Stimulus-Driven Attentional Limit to Conscious Perception

    ERIC Educational Resources Information Center

    Asplund, Christopher L.; Todd, J. Jay; Snyder, A. P.; Gilbert, Christopher M.; Marois, Rene

    2010-01-01

    The cost of attending to a visual event can be the failure to consciously detect other events. This processing limitation is well illustrated by the attentional blink paradigm, in which searching for and attending to a target presented in a rapid serial visual presentation stream of distractors can impair one's ability to detect a second target…

  4. Can Blindsight Be Superior to "Sighted-Sight"?

    ERIC Educational Resources Information Center

    Trevethan, Ceri T.; Sahraie, Arash; Weiskrantz, Larry

    2007-01-01

    DB, the first blindsight case to be tested extensively (Weiskrantz, 1986) has demonstrated the ability to detect and discriminate a range of visual stimuli presented within his perimetrically blind visual field defect. In a temporal two alternative forced choice (2AFC) detection experiment we have investigated the limits of DB's detection ability…

  5. Remembering Complex Objects in Visual Working Memory: Do Capacity Limits Restrict Objects or Features?

    PubMed Central

    Hardman, Kyle; Cowan, Nelson

    2014-01-01

    Visual working memory stores stimuli from our environment as representations that can be accessed by high-level control processes. This study addresses a longstanding debate in the literature about whether storage limits in visual working memory include a limit to the complexity of discrete items. We examined the issue with a number of change-detection experiments that used complex stimuli which possessed multiple features per stimulus item. We manipulated the number of relevant features of the stimulus objects in order to vary feature load. In all of our experiments, we found that increased feature load led to a reduction in change-detection accuracy. However, we found that feature load alone could not account for the results, but that a consideration of the number of relevant objects was also required. This study supports capacity limits for both feature and object storage in visual working memory. PMID:25089739

  6. Orienting Attention in Visual Working Memory Reduces Interference from Memory Probes

    ERIC Educational Resources Information Center

    Makovski, Tal; Sussman, Rachel; Jiang, Yuhong V.

    2008-01-01

    Given a changing visual environment, and the limited capacity of visual working memory (VWM), the contents of VWM must be in constant flux. Using a change detection task, the authors show that VWM is subject to obligatory updating in the face of new information. Change detection performance is enhanced when the item that may change is…

  7. Optimization of Visual Information Presentation for Visual Prosthesis.

    PubMed

    Guo, Fei; Yang, Yuan; Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis.

  8. Optimization of Visual Information Presentation for Visual Prosthesis

    PubMed Central

    Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis. PMID:29731769

  9. To See or Not to See: Investigating Detectability of Ganges River Dolphins Using a Combined Visual-Acoustic Survey

    PubMed Central

    Richman, Nadia I.; Gibbons, James M.; Turvey, Samuel T.; Akamatsu, Tomonari; Ahmed, Benazir; Mahabub, Emile; Smith, Brian D.; Jones, Julia P. G.

    2014-01-01

    Detection of animals during visual surveys is rarely perfect or constant, and failure to account for imperfect detectability affects the accuracy of abundance estimates. Freshwater cetaceans are among the most threatened group of mammals, and visual surveys are a commonly employed method for estimating population size despite concerns over imperfect and unquantified detectability. We used a combined visual-acoustic survey to estimate detectability of Ganges River dolphins (Platanista gangetica gangetica) in four waterways of southern Bangladesh. The combined visual-acoustic survey resulted in consistently higher detectability than a single observer-team visual survey, thereby improving power to detect trends. Visual detectability was particularly low for dolphins close to meanders where these habitat features temporarily block the view of the preceding river surface. This systematic bias in detectability during visual-only surveys may lead researchers to underestimate the importance of heavily meandering river reaches. Although the benefits of acoustic surveys are increasingly recognised for marine cetaceans, they have not been widely used for monitoring abundance of freshwater cetaceans due to perceived costs and technical skill requirements. We show that acoustic surveys are in fact a relatively cost-effective approach for surveying freshwater cetaceans, once it is acknowledged that methods that do not account for imperfect detectability are of limited value for monitoring. PMID:24805782

  10. To see or not to see: investigating detectability of Ganges River dolphins using a combined visual-acoustic survey.

    PubMed

    Richman, Nadia I; Gibbons, James M; Turvey, Samuel T; Akamatsu, Tomonari; Ahmed, Benazir; Mahabub, Emile; Smith, Brian D; Jones, Julia P G

    2014-01-01

    Detection of animals during visual surveys is rarely perfect or constant, and failure to account for imperfect detectability affects the accuracy of abundance estimates. Freshwater cetaceans are among the most threatened group of mammals, and visual surveys are a commonly employed method for estimating population size despite concerns over imperfect and unquantified detectability. We used a combined visual-acoustic survey to estimate detectability of Ganges River dolphins (Platanista gangetica gangetica) in four waterways of southern Bangladesh. The combined visual-acoustic survey resulted in consistently higher detectability than a single observer-team visual survey, thereby improving power to detect trends. Visual detectability was particularly low for dolphins close to meanders where these habitat features temporarily block the view of the preceding river surface. This systematic bias in detectability during visual-only surveys may lead researchers to underestimate the importance of heavily meandering river reaches. Although the benefits of acoustic surveys are increasingly recognised for marine cetaceans, they have not been widely used for monitoring abundance of freshwater cetaceans due to perceived costs and technical skill requirements. We show that acoustic surveys are in fact a relatively cost-effective approach for surveying freshwater cetaceans, once it is acknowledged that methods that do not account for imperfect detectability are of limited value for monitoring.

  11. Peripheral detection and resolution with mid-/long-wavelength and short-wavelength sensitive cone systems.

    PubMed

    Zhu, Hai-Feng; Zele, Andrew J; Suheimat, Marwan; Lambert, Andrew J; Atchison, David A

    2016-08-01

    This study compared neural resolution and detection limits of the human mid-/long-wavelength and short-wavelength cone systems with anatomical estimates of photoreceptor and retinal ganglion cell spacings and sizes. Detection and resolution limits were measured from central fixation out to 35° eccentricity across the horizontal visual field using a modified Lotmar interferometer. The mid-/long-wavelength cone system was studied using a green (550 nm) test stimulus to which S-cones have low sensitivity. To bias resolution and detection to the short-wavelength cone system, a blue (450 nm) test stimulus was presented against a bright yellow background that desensitized the M- and L-cones. Participants were three trichromatic males with normal visual functions. With green stimuli, resolution showed a steep central-peripheral gradient that was similar between participants, whereas the detection gradient was shallower and patterns were different between participants. Detection and resolution with blue stimuli were poorer than for green stimuli. The detection of blue stimuli was superior to resolution across the horizontal visual field and the patterns were different between participants. The mid-/long-wavelength cone system's resolution is limited by midget ganglion cell spacing and its detection is limited by the size of the M- and L-cone photoreceptors, consistent with previous observations. We found that no such simple relationships occur for the short-wavelength cone system between resolution and the bistratified ganglion cell spacing, nor between detection and the S-cone photoreceptor sizes.

  12. Remembering complex objects in visual working memory: do capacity limits restrict objects or features?

    PubMed

    Hardman, Kyle O; Cowan, Nelson

    2015-03-01

    Visual working memory stores stimuli from our environment as representations that can be accessed by high-level control processes. This study addresses a longstanding debate in the literature about whether storage limits in visual working memory include a limit to the complexity of discrete items. We examined the issue with a number of change-detection experiments that used complex stimuli that possessed multiple features per stimulus item. We manipulated the number of relevant features of the stimulus objects in order to vary feature load. In all of our experiments, we found that increased feature load led to a reduction in change-detection accuracy. However, we found that feature load alone could not account for the results but that a consideration of the number of relevant objects was also required. This study supports capacity limits for both feature and object storage in visual working memory. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  13. High-resolution remotely sensed small target detection by imitating fly visual perception mechanism.

    PubMed

    Huang, Fengchen; Xu, Lizhong; Li, Min; Tang, Min

    2012-01-01

    The difficulty and limitation of small target detection methods for high-resolution remote sensing data have been a recent research hot spot. Inspired by the information capture and processing theory of fly visual system, this paper endeavors to construct a characterized model of information perception and make use of the advantages of fast and accurate small target detection under complex varied nature environment. The proposed model forms a theoretical basis of small target detection for high-resolution remote sensing data. After the comparison of prevailing simulation mechanism behind fly visual systems, we propose a fly-imitated visual system method of information processing for high-resolution remote sensing data. A small target detector and corresponding detection algorithm are designed by simulating the mechanism of information acquisition, compression, and fusion of fly visual system and the function of pool cell and the character of nonlinear self-adaption. Experiments verify the feasibility and rationality of the proposed small target detection model and fly-imitated visual perception method.

  14. The accuracy of confrontation visual field test in comparison with automated perimetry.

    PubMed Central

    Johnson, L. N.; Baloh, F. G.

    1991-01-01

    The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764

  15. Visual detection of nucleic acids based on Mie scattering and the magnetophoretic effect.

    PubMed

    Zhao, Zichen; Chen, Shan; Ho, John Kin Lim; Chieng, Ching-Chang; Chen, Ting-Hsuan

    2015-12-07

    Visual detection of nucleic acid biomarkers is a simple and convenient approach to point-of-care applications. However, issues of sensitivity and the handling of complex bio-fluids have posed challenges. Here we report on a visual method detecting nucleic acids using Mie scattering of polystyrene microparticles and the magnetophoretic effect. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) were surface-functionalised with oligonucleotide probes, which can hybridise with target oligonucleotides in juxtaposition and lead to the formation of MMPs-targets-PMPs sandwich structures. Using an externally applied magnetic field, the magnetophoretic effect attracts the sandwich structure to the sidewall, which reduces the suspended PMPs and leads to a change in the light transmission via the Mie scattering. Based on the high extinction coefficient of the Mie scattering (∼3 orders of magnitude greater than that of the commonly used gold nanoparticles), our results showed the limit of detection to be 4 pM using a UV-Vis spectrometer or 10 pM by direct visual inspection. Meanwhile, we also demonstrated that this method is compatible with multiplex assays and detection in complex bio-fluids, such as whole blood or a pool of nucleic acids, without purification in advance. With a simplified operation procedure, low instrumentation requirement, high sensitivity and compatibility with complex bio-fluids, this method provides an ideal solution for visual detection of nucleic acids in resource-limited settings.

  16. Automated quantification of myocardial perfusion SPECT using simplified normal limits.

    PubMed

    Slomka, Piotr J; Nishina, Hidetaka; Berman, Daniel S; Akincioglu, Cigdem; Abidov, Aiden; Friedman, John D; Hayes, Sean W; Germano, Guido

    2005-01-01

    To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds. Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance. Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.

  17. High contrast sensitivity for visually guided flight control in bumblebees.

    PubMed

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  18. The Comparison of Visual Working Memory Representations with Perceptual Inputs

    PubMed Central

    Hyun, Joo-seok; Woodman, Geoffrey F.; Vogel, Edward K.; Hollingworth, Andrew

    2008-01-01

    The human visual system can notice differences between memories of previous visual inputs and perceptions of new visual inputs, but the comparison process that detects these differences has not been well characterized. This study tests the hypothesis that differences between the memory of a stimulus array and the perception of a new array are detected in a manner that is analogous to the detection of simple features in visual search tasks. That is, just as the presence of a task-relevant feature in visual search can be detected in parallel, triggering a rapid shift of attention to the object containing the feature, the presence of a memory-percept difference along a task-relevant dimension can be detected in parallel, triggering a rapid shift of attention to the changed object. Supporting evidence was obtained in a series of experiments that examined manual reaction times, saccadic reaction times, and event-related potential latencies. However, these experiments also demonstrated that a slow, limited-capacity process must occur before the observer can make a manual change-detection response. PMID:19653755

  19. Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples.

    PubMed

    Berger, Jason; Upton, Colin; Springer, Elyah

    2018-04-23

    Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.

  20. Studying the lower limit of human vision with a single-photon source

    NASA Astrophysics Data System (ADS)

    Holmes, Rebecca; Christensen, Bradley; Street, Whitney; Wang, Ranxiao; Kwiat, Paul

    2015-05-01

    Humans can detect a visual stimulus of just a few photons. Exactly how few is not known--psychological and physiological research have suggested that the detection threshold may be as low as one photon, but the question has never been directly tested. Using a source of heralded single photons based on spontaneous parametric downconversion, we can directly characterize the lower limit of vision. This system can also be used to study temporal and spatial integration in the visual system, and to study visual attention with EEG. We may eventually even be able to investigate how human observers perceive quantum effects such as superposition and entanglement. Our progress and some preliminary results will be discussed.

  1. Detecting Visually Observable Disease Symptoms from Faces.

    PubMed

    Wang, Kuan; Luo, Jiebo

    2016-12-01

    Recent years have witnessed an increasing interest in the application of machine learning to clinical informatics and healthcare systems. A significant amount of research has been done on healthcare systems based on supervised learning. In this study, we present a generalized solution to detect visually observable symptoms on faces using semi-supervised anomaly detection combined with machine vision algorithms. We rely on the disease-related statistical facts to detect abnormalities and classify them into multiple categories to narrow down the possible medical reasons of detecting. Our method is in contrast with most existing approaches, which are limited by the availability of labeled training data required for supervised learning, and therefore offers the major advantage of flagging any unusual and visually observable symptoms.

  2. Auditory enhancement of visual perception at threshold depends on visual abilities.

    PubMed

    Caclin, Anne; Bouchet, Patrick; Djoulah, Farida; Pirat, Elodie; Pernier, Jacques; Giard, Marie-Hélène

    2011-06-17

    Whether or not multisensory interactions can improve detection thresholds, and thus widen the range of perceptible events is a long-standing debate. Here we revisit this question, by testing the influence of auditory stimuli on visual detection threshold, in subjects exhibiting a wide range of visual-only performance. Above the perceptual threshold, crossmodal interactions have indeed been reported to depend on the subject's performance when the modalities are presented in isolation. We thus tested normal-seeing subjects and short-sighted subjects wearing their usual glasses. We used a paradigm limiting potential shortcomings of previous studies: we chose a criterion-free threshold measurement procedure and precluded exogenous cueing effects by systematically presenting a visual cue whenever a visual target (a faint Gabor patch) might occur. Using this carefully controlled procedure, we found that concurrent sounds only improved visual detection thresholds in the sub-group of subjects exhibiting the poorest performance in the visual-only conditions. In these subjects, for oblique orientations of the visual stimuli (but not for vertical or horizontal targets), the auditory improvement was still present when visual detection was already helped with flanking visual stimuli generating a collinear facilitation effect. These findings highlight that crossmodal interactions are most efficient to improve perceptual performance when an isolated modality is deficient. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Visual detection of glial cell line-derived neurotrophic factor based on a molecular translator and isothermal strand-displacement polymerization reaction.

    PubMed

    Zhang, Li-Yong; Xing, Tao; Du, Li-Xin; Li, Qing-Min; Liu, Wei-Dong; Wang, Ji-Yue; Cai, Jing

    2015-01-01

    Glial cell line-derived neurotrophic factor (GDNF) is a small protein that potently promotes the survival of many types of neurons. Detection of GDNF is vital to monitoring the survival of sympathetic and sensory neurons. However, the specific method for GDNF detection is also un-discovered. The purpose of this study is to explore the method for protein detection of GDNF. A novel visual detection method based on a molecular translator and isothermal strand-displacement polymerization reaction (ISDPR) has been proposed for the detection of GDNF. In this study, a molecular translator was employed to convert the input protein to output deoxyribonucleic acid signal, which was further amplified by ISDPR. The product of ISDPR was detected by a lateral flow biosensor within 30 minutes. This novel visual detection method based on a molecular translator and ISDPR has very high sensitivity and selectivity, with a dynamic response ranging from 1 pg/mL to 10 ng/mL, and the detection limit was 1 pg/mL of GDNF. This novel visual detection method exhibits high sensitivity and selectivity, which is very simple and universal for GDNF detection to help disease therapy in clinical practice.

  4. Shared filtering processes link attentional and visual short-term memory capacity limits.

    PubMed

    Bettencourt, Katherine C; Michalka, Samantha W; Somers, David C

    2011-09-30

    Both visual attention and visual short-term memory (VSTM) have been shown to have capacity limits of 4 ± 1 objects, driving the hypothesis that they share a visual processing buffer. However, these capacity limitations also show strong individual differences, making the degree to which these capacities are related unclear. Moreover, other research has suggested a distinction between attention and VSTM buffers. To explore the degree to which capacity limitations reflect the use of a shared visual processing buffer, we compared individual subject's capacities on attentional and VSTM tasks completed in the same testing session. We used a multiple object tracking (MOT) and a VSTM change detection task, with varying levels of distractors, to measure capacity. Significant correlations in capacity were not observed between the MOT and VSTM tasks when distractor filtering demands differed between the tasks. Instead, significant correlations were seen when the tasks shared spatial filtering demands. Moreover, these filtering demands impacted capacity similarly in both attention and VSTM tasks. These observations fail to support the view that visual attention and VSTM capacity limits result from a shared buffer but instead highlight the role of the resource demands of underlying processes in limiting capacity.

  5. Measured Visual Motion Sensitivity at Fixed Contrast in the Periphery and Far Periphery

    DTIC Science & Technology

    2017-08-01

    group Soldier performance. Soldier performance depends on visual detection of enemy personnel and materiel. Vision modeling in IWARS is neither...a highly time-critical and order- dependent activity, these unrealistic characterizations of target detection time and order severely limit the...recognize that MVTs should depend on target contrast, so we selected a target design different from that used in the Monaco et al. (2007) study. Based

  6. Signal detection evidence for limited capacity in visual search

    PubMed Central

    Fencsik, David E.; Flusberg, Stephen J.; Horowitz, Todd S.; Wolfe, Jeremy M.

    2014-01-01

    The nature of capacity limits (if any) in visual search has been a topic of controversy for decades. In 30 years of work, researchers have attempted to distinguish between two broad classes of visual search models. Attention-limited models have proposed two stages of perceptual processing: an unlimited-capacity preattentive stage, and a limited-capacity selective attention stage. Conversely, noise-limited models have proposed a single, unlimited-capacity perceptual processing stage, with decision processes influenced only by stochastic noise. Here, we use signal detection methods to test a strong prediction of attention-limited models. In standard attention-limited models, performance of some searches (feature searches) should only be limited by a preattentive stage. Other search tasks (e.g., spatial configuration search for a “2” among “5”s) should be additionally limited by an attentional bottleneck. We equated average accuracies for a feature and a spatial configuration search over set sizes of 1–8 for briefly presented stimuli. The strong prediction of attention-limited models is that, given overall equivalence in performance, accuracy should be better on the spatial configuration search than on the feature search for set size 1, and worse for set size 8. We confirm this crossover interaction and show that it is problematic for at least one class of one-stage decision models. PMID:21901574

  7. Carbon nanotube-based labels for highly sensitive colorimetric and aggregation-based visual detection of nucleic acids

    NASA Astrophysics Data System (ADS)

    Lee, Ai Cheng; Ye, Jian-Shan; Ngin Tan, Swee; Poenar, Daniel P.; Sheu, Fwu-Shan; Kiat Heng, Chew; Meng Lim, Tit

    2007-11-01

    A novel carbon nanotube (CNT) derived label capable of dramatic signal amplification of nucleic acid detection and direct visual detection of target hybridization has been developed. Highly sensitive colorimetric detection of human acute lymphocytic leukemia (ALL) related oncogene sequences amplified by the novel CNT-based label was demonstrated. Atomic force microscope (AFM) images confirmed that a monolayer of horseradish peroxidase and detection probe molecules was immobilized along the carboxylated CNT carrier. The resulting CNT labels significantly enhanced the nucleic acid assay sensitivity by at least 1000 times compared to that of conventional labels used in enzyme-linked oligosorbent assay (ELOSA). An excellent detection limit of 1 × 10-12 M (60 × 10-18 mol in 60 µl) and a four-order wide dynamic range of target concentration were achieved. Hybridizations using these labels were coupled to a concentration-dependent formation of visible dark aggregates. Targets can thus be detected simply with visual inspection, eliminating the need for expensive and sophisticated detection systems. The approach holds promise for ultrasensitive and low cost visual inspection and colorimetric nucleic acid detection in point-of-care and early disease diagnostic application.

  8. A bottom-up model of spatial attention predicts human error patterns in rapid scene recognition.

    PubMed

    Einhäuser, Wolfgang; Mundhenk, T Nathan; Baldi, Pierre; Koch, Christof; Itti, Laurent

    2007-07-20

    Humans demonstrate a peculiar ability to detect complex targets in rapidly presented natural scenes. Recent studies suggest that (nearly) no focal attention is required for overall performance in such tasks. Little is known, however, of how detection performance varies from trial to trial and which stages in the processing hierarchy limit performance: bottom-up visual processing (attentional selection and/or recognition) or top-down factors (e.g., decision-making, memory, or alertness fluctuations)? To investigate the relative contribution of these factors, eight human observers performed an animal detection task in natural scenes presented at 20 Hz. Trial-by-trial performance was highly consistent across observers, far exceeding the prediction of independent errors. This consistency demonstrates that performance is not primarily limited by idiosyncratic factors but by visual processing. Two statistical stimulus properties, contrast variation in the target image and the information-theoretical measure of "surprise" in adjacent images, predict performance on a trial-by-trial basis. These measures are tightly related to spatial attention, demonstrating that spatial attention and rapid target detection share common mechanisms. To isolate the causal contribution of the surprise measure, eight additional observers performed the animal detection task in sequences that were reordered versions of those all subjects had correctly recognized in the first experiment. Reordering increased surprise before and/or after the target while keeping the target and distractors themselves unchanged. Surprise enhancement impaired target detection in all observers. Consequently, and contrary to several previously published findings, our results demonstrate that attentional limitations, rather than target recognition alone, affect the detection of targets in rapidly presented visual sequences.

  9. Comparative psychophysics of bumblebee and honeybee colour discrimination and object detection.

    PubMed

    Dyer, Adrian G; Spaethe, Johannes; Prack, Sabina

    2008-07-01

    Bumblebee (Bombus terrestris) discrimination of targets with broadband reflectance spectra was tested using simultaneous viewing conditions, enabling an accurate determination of the perceptual limit of colour discrimination excluding confounds from memory coding (experiment 1). The level of colour discrimination in bumblebees, and honeybees (Apis mellifera) (based upon previous observations), exceeds predictions of models considering receptor noise in the honeybee. Bumblebee and honeybee photoreceptors are similar in spectral shape and spacing, but bumblebees exhibit significantly poorer colour discrimination in behavioural tests, suggesting possible differences in spatial or temporal signal processing. Detection of stimuli in a Y-maze was evaluated for bumblebees (experiment 2) and honeybees (experiment 3). Honeybees detected stimuli containing both green-receptor-contrast and colour contrast at a visual angle of approximately 5 degrees , whilst stimuli that contained only colour contrast were only detected at a visual angle of 15 degrees . Bumblebees were able to detect these stimuli at a visual angle of 2.3 degrees and 2.7 degrees , respectively. A comparison of the experiments suggests a tradeoff between colour discrimination and colour detection in these two species, limited by the need to pool colour signals to overcome receptor noise. We discuss the colour processing differences and possible adaptations to specific ecological habitats.

  10. An efficient probe for rapid detection of cyanide in water at parts per billion levels and naked-eye detection of endogenous cyanide.

    PubMed

    Kumari, Namita; Jha, Satadru; Bhattacharya, Santanu

    2014-03-01

    A new molecular probe based on an oxidized bis-indolyl skeleton has been developed for rapid and sensitive visual detection of cyanide ions in water and also for the detection of endogenously bound cyanide. The probe allows the "naked-eye" detection of cyanide ions in water with a visual color change from red to yellow (Δλmax =80 nm) with the immediate addition of the probe. It shows high selectivity towards the cyanide ion without any interference from other anions. The detection of cyanide by the probe is ratiometric, thus making the detection quantitative. A Michael-type addition reaction of the probe with the cyanide ion takes place during this chemodosimetric process. In water, the detection limit was found to be at the parts per million level, which improved drastically when a neutral micellar medium was employed, and it showed a parts-per-billion-level detection, which is even 25-fold lower than the permitted limits of cyanide in water. The probe could also efficiently detect the endogenously bound cyanide in cassava (a staple food) with a clear visual color change without requiring any sample pretreatment and/or any special reaction conditions such as pH or temperature. Thus the probe could serve as a practical naked-eye probe for "in-field" experiments without requiring any sophisticated instruments. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Visual detection of glial cell line-derived neurotrophic factor based on a molecular translator and isothermal strand-displacement polymerization reaction

    PubMed Central

    Zhang, Li-Yong; Xing, Tao; Du, Li-Xin; Li, Qing-Min; Liu, Wei-Dong; Wang, Ji-Yue; Cai, Jing

    2015-01-01

    Background Glial cell line-derived neurotrophic factor (GDNF) is a small protein that potently promotes the survival of many types of neurons. Detection of GDNF is vital to monitoring the survival of sympathetic and sensory neurons. However, the specific method for GDNF detection is also un-discovered. The purpose of this study is to explore the method for protein detection of GDNF. Methods A novel visual detection method based on a molecular translator and isothermal strand-displacement polymerization reaction (ISDPR) has been proposed for the detection of GDNF. In this study, a molecular translator was employed to convert the input protein to output deoxyribonucleic acid signal, which was further amplified by ISDPR. The product of ISDPR was detected by a lateral flow biosensor within 30 minutes. Results This novel visual detection method based on a molecular translator and ISDPR has very high sensitivity and selectivity, with a dynamic response ranging from 1 pg/mL to 10 ng/mL, and the detection limit was 1 pg/mL of GDNF. Conclusion This novel visual detection method exhibits high sensitivity and selectivity, which is very simple and universal for GDNF detection to help disease therapy in clinical practice. PMID:25848224

  12. Ultrasensitive Visual Detection of HIV DNA Biomarkers via a Multi-amplification Nanoplatform.

    PubMed

    Long, Yuyin; Zhou, Cuisong; Wang, Congmin; Cai, Honglian; Yin, Cuiyun; Yang, Qiufang; Xiao, Dan

    2016-04-01

    Methodologies to detect disease biomarkers at ultralow concentrations can potentially improve the standard of living. A facile and label-free multi-amplification strategy is proposed for the ultrasensitive visual detection of HIV DNA biomarkers in real physiological media. This multi-amplification strategy not only exhibits a signficantly low detection limit down to 4.8 pM but also provides a label-free, cost-effective and facile technique for visualizing a few molecules of nucleic acid analyte with the naked eye. Importantly, the biosensor is capable of discriminating single-based mismatch lower than 5.0 nM in human serum samples. Moreover, the visual sensing platform exhibits excellent specificity, acceptable reusability and a long-term stability. All these advantages could be attributed to the nanofibrous sensing platform that 1) has a high surface-area-to-volume provided by electrospun nanofibrous membrane, and 2) combines glucose oxidase (GOx) biocatalysis, DNAzyme-catalyzed colorimetric reaction and catalytic hairpin assembly (CHA) recycling amplification together. This multi-amplification nanoplatform promises label-free and visual single-based mismatch DNA monitoring with high sensitivity and specificity, suggesting wide applications that range from virus detection to genetic disease diagnosis.

  13. Conscious visual memory with minimal attention.

    PubMed

    Pinto, Yair; Vandenbroucke, Annelinde R; Otten, Marte; Sligte, Ilja G; Seth, Anil K; Lamme, Victor A F

    2017-02-01

    Is conscious visual perception limited to the locations that a person attends? The remarkable phenomenon of change blindness, which shows that people miss nearly all unattended changes in a visual scene, suggests the answer is yes. However, change blindness is found after visual interference (a mask or a new scene), so that subjects have to rely on working memory (WM), which has limited capacity, to detect the change. Before such interference, however, a much larger capacity store, called fragile memory (FM), which is easily overwritten by newly presented visual information, is present. Whether these different stores depend equally on spatial attention is central to the debate on the role of attention in conscious vision. In 2 experiments, we found that minimizing spatial attention almost entirely erases visual WM, as expected. Critically, FM remains largely intact. Moreover, minimally attended FM responses yield accurate metacognition, suggesting that conscious memory persists with limited spatial attention. Together, our findings help resolve the fundamental issue of how attention affects perception: Both visual consciousness and memory can be supported by only minimal attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. The Role of Temporal Disparity on Audiovisual Integration in Low-Vision Individuals.

    PubMed

    Targher, Stefano; Micciolo, Rocco; Occelli, Valeria; Zampini, Massimiliano

    2017-12-01

    Recent findings have shown that sounds improve visual detection in low vision individuals when the audiovisual stimuli pairs of stimuli are presented simultaneously and from the same spatial position. The present study purports to investigate the temporal aspects of the audiovisual enhancement effect previously reported. Low vision participants were asked to detect the presence of a visual stimulus (yes/no task) presented either alone or together with an auditory stimulus at different stimulus onset asynchronies (SOAs). In the first experiment, the sound was presented either simultaneously or before the visual stimulus (i.e., SOAs 0, 100, 250, 400 ms). The results show that the presence of a task-irrelevant auditory stimulus produced a significant visual detection enhancement in all the conditions. In the second experiment, the sound was either synchronized with, or randomly preceded/lagged behind the visual stimulus (i.e., SOAs 0, ± 250, ± 400 ms). The visual detection enhancement was reduced in magnitude and limited only to the synchronous condition and to the condition in which the sound stimulus was presented 250 ms before the visual stimulus. Taken together, the evidence of the present study seems to suggest that audiovisual interaction in low vision individuals is highly modulated by top-down mechanisms.

  15. Assistive obstacle detection and navigation devices for vision-impaired users.

    PubMed

    Ong, S K; Zhang, J; Nee, A Y C

    2013-09-01

    Quality of life for the visually impaired is an urgent worldwide issue that needs to be addressed. Obstacle detection is one of the most important navigation tasks for the visually impaired. In this research, a novel range sensor placement scheme is proposed in this paper for the development of obstacle detection devices. Based on this scheme, two prototypes have been developed targeting at different user groups. This paper discusses the design issues, functional modules and the evaluation tests carried out for both prototypes. Implications for Rehabilitation Visual impairment problem is becoming more severe due to the worldwide ageing population. Individuals with visual impairment require assistance from assistive devices in daily navigation tasks. Traditional assistive devices that assist navigation may have certain drawbacks, such as the limited sensing range of a white cane. Obstacle detection devices applying the range sensor technology can identify road conditions with a higher sensing range to notify the users of potential dangers in advance.

  16. Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal

    2018-02-01

    We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.

  17. Detection method of flexion relaxation phenomenon based on wavelets for patients with low back pain

    NASA Astrophysics Data System (ADS)

    Nougarou, François; Massicotte, Daniel; Descarreaux, Martin

    2012-12-01

    The flexion relaxation phenomenon (FRP) can be defined as a reduction or silence of myoelectric activity of the lumbar erector spinae muscle during full trunk flexion. It is typically absent in patients with chronic low back pain (LBP). Before any broad clinical utilization of this neuromuscular response can be made, effective, standardized, and accurate methods of identifying FRP limits are needed. However, this phenomenon is clearly more difficult to detect for LBP patients than for healthy patients. The main goal of this study is to develop an automated method based on wavelet transformation that would improve time point limits detection of surface electromyography signals of the FRP in case of LBP patients. Conventional visual identification and proposed automated methods of time point limits detection of relaxation phase were compared on experimental data using criteria of accuracy and repeatability based on physiological properties. The evaluation demonstrates that the use of wavelet transform (WT) yields better results than methods without wavelet decomposition. Furthermore, methods based on wavelet per packet transform are more effective than algorithms employing discrete WT. Compared to visual detection, in addition to demonstrating an obvious saving of time, the use of wavelet per packet transform improves the accuracy and repeatability in the detection of the FRP limits. These results clearly highlight the value of the proposed technique in identifying onset and offset of the flexion relaxation response in LBP subjects.

  18. Systematic distortions of perceptual stability investigated using immersive virtual reality

    PubMed Central

    Tcheang, Lili; Gilson, Stuart J.; Glennerster, Andrew

    2010-01-01

    Using an immersive virtual reality system, we measured the ability of observers to detect the rotation of an object when its movement was yoked to the observer's own translation. Most subjects had a large bias such that a static object appeared to rotate away from them as they moved. Thresholds for detecting target rotation were similar to those for an equivalent speed discrimination task carried out by static observers, suggesting that visual discrimination is the predominant limiting factor in detecting target rotation. Adding a stable visual reference frame almost eliminated the bias. Varying the viewing distance of the target had little effect, consistent with observers under-estimating distance walked. However, accuracy of walking to a briefly presented visual target was high and not consistent with an under-estimation of distance walked. We discuss implications for theories of a task-independent representation of visual space. PMID:15845248

  19. Evidence for unlimited capacity processing of simple features in visual cortex

    PubMed Central

    White, Alex L.; Runeson, Erik; Palmer, John; Ernst, Zachary R.; Boynton, Geoffrey M.

    2017-01-01

    Performance in many visual tasks is impaired when observers attempt to divide spatial attention across multiple visual field locations. Correspondingly, neuronal response magnitudes in visual cortex are often reduced during divided compared with focused spatial attention. This suggests that early visual cortex is the site of capacity limits, where finite processing resources must be divided among attended stimuli. However, behavioral research demonstrates that not all visual tasks suffer such capacity limits: The costs of divided attention are minimal when the task and stimulus are simple, such as when searching for a target defined by orientation or contrast. To date, however, every neuroimaging study of divided attention has used more complex tasks and found large reductions in response magnitude. We bridged that gap by using functional magnetic resonance imaging to measure responses in the human visual cortex during simple feature detection. The first experiment used a visual search task: Observers detected a low-contrast Gabor patch within one or four potentially relevant locations. The second experiment used a dual-task design, in which observers made independent judgments of Gabor presence in patches of dynamic noise at two locations. In both experiments, blood-oxygen level–dependent (BOLD) signals in the retinotopic cortex were significantly lower for ignored than attended stimuli. However, when observers divided attention between multiple stimuli, BOLD signals were not reliably reduced and behavioral performance was unimpaired. These results suggest that processing of simple features in early visual cortex has unlimited capacity. PMID:28654964

  20. The wisdom of crowds for visual search

    PubMed Central

    Juni, Mordechai Z.; Eckstein, Miguel P.

    2017-01-01

    Decision-making accuracy typically increases through collective integration of people’s judgments into group decisions, a phenomenon known as the wisdom of crowds. For simple perceptual laboratory tasks, classic signal detection theory specifies the upper limit for collective integration benefits obtained by weighted averaging of people’s confidences, and simple majority voting can often approximate that limit. Life-critical perceptual decisions often involve searching large image data (e.g., medical, security, and aerial imagery), but the expected benefits and merits of using different pooling algorithms are unknown for such tasks. Here, we show that expected pooling benefits are significantly greater for visual search than for single-location perceptual tasks and the prediction given by classic signal detection theory. In addition, we show that simple majority voting obtains inferior accuracy benefits for visual search relative to averaging and weighted averaging of observers’ confidences. Analysis of gaze behavior across observers suggests that the greater collective integration benefits for visual search arise from an interaction between the foveated properties of the human visual system (high foveal acuity and low peripheral acuity) and observers’ nonexhaustive search patterns, and can be predicted by an extended signal detection theory framework with trial to trial sampling from a varying mixture of high and low target detectabilities across observers (SDT-MIX). These findings advance our theoretical understanding of how to predict and enhance the wisdom of crowds for real world search tasks and could apply more generally to any decision-making task for which the minority of group members with high expertise varies from decision to decision. PMID:28490500

  1. An optimized content-aware image retargeting method: toward expanding the perceived visual field of the high-density retinal prosthesis recipients

    NASA Astrophysics Data System (ADS)

    Li, Heng; Zeng, Yajie; Lu, Zhuofan; Cao, Xiaofei; Su, Xiaofan; Sui, Xiaohong; Wang, Jing; Chai, Xinyu

    2018-04-01

    Objective. Retinal prosthesis devices have shown great value in restoring some sight for individuals with profoundly impaired vision, but the visual acuity and visual field provided by prostheses greatly limit recipients’ visual experience. In this paper, we employ computer vision approaches to seek to expand the perceptible visual field in patients implanted potentially with a high-density retinal prosthesis while maintaining visual acuity as much as possible. Approach. We propose an optimized content-aware image retargeting method, by introducing salient object detection based on color and intensity-difference contrast, aiming to remap important information of a scene into a small visual field and preserve their original scale as much as possible. It may improve prosthetic recipients’ perceived visual field and aid in performing some visual tasks (e.g. object detection and object recognition). To verify our method, psychophysical experiments, detecting object number and recognizing objects, are conducted under simulated prosthetic vision. As control, we use three other image retargeting techniques, including Cropping, Scaling, and seam-assisted shrinkability. Main results. Results show that our method outperforms in preserving more key features and has significantly higher recognition accuracy in comparison with other three image retargeting methods under the condition of small visual field and low-resolution. Significance. The proposed method is beneficial to expand the perceived visual field of prosthesis recipients and improve their object detection and recognition performance. It suggests that our method may provide an effective option for image processing module in future high-density retinal implants.

  2. Highly sensitive on-site detection of glucose in human urine with naked eye based on enzymatic-like reaction mediated etching of gold nanorods.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Cheng, Fangbin; Zhang, Yaowen; Chen, Lingxin

    2017-03-15

    Based on enzymatic-like reaction mediated etching of gold nanorods (GNRs), an ultrasensitive visual method was developed for on-site detection of urine glucose. With the catalysis of MoO 4 2 - , GNRs were efficiently etched by H 2 O 2 which was generated by glucose-glucose oxidase enzymatic reaction. The etching of GNRs lead to a blue-shift of logitudinal localized surface plasmon resonance of GNRs, accompanied by an obvious color change from blue to red. The peak-shift and the color change can be used for detection of glucose by the spectrophotometer and the naked eyes. Under optimal condition, an excellent sensitivity toward glucose is obtained with a detection limit of 0.1μM and a visual detection limit of 3μM in buffer solution. Benefiting from the high sensitivity, the successful colorimetric detection of glucose in original urine samples was achieved, which indicates the practical applicability to the on-site determination of urine glucose. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Ultrafast scene detection and recognition with limited visual information

    PubMed Central

    Hagmann, Carl Erick; Potter, Mary C.

    2016-01-01

    Humans can detect target color pictures of scenes depicting concepts like picnic or harbor in sequences of six or twelve pictures presented as briefly as 13 ms, even when the target is named after the sequence (Potter, Wyble, Hagmann, & McCourt, 2014). Such rapid detection suggests that feedforward processing alone enabled detection without recurrent cortical feedback. There is debate about whether coarse, global, low spatial frequencies (LSFs) provide predictive information to high cortical levels through the rapid magnocellular (M) projection of the visual path, enabling top-down prediction of possible object identities. To test the “Fast M” hypothesis, we compared detection of a named target across five stimulus conditions: unaltered color, blurred color, grayscale, thresholded monochrome, and LSF pictures. The pictures were presented for 13–80 ms in six-picture rapid serial visual presentation (RSVP) sequences. Blurred, monochrome, and LSF pictures were detected less accurately than normal color or grayscale pictures. When the target was named before the sequence, all picture types except LSF resulted in above-chance detection at all durations. Crucially, when the name was given only after the sequence, performance dropped and the monochrome and LSF pictures (but not the blurred pictures) were at or near chance. Thus, without advance information, monochrome and LSF pictures were rarely understood. The results offer only limited support for the Fast M hypothesis, suggesting instead that feedforward processing is able to activate conceptual representations without complementary reentrant processing. PMID:28255263

  4. Remote Sensing of Martian Terrain Hazards via Visually Salient Feature Detection

    NASA Astrophysics Data System (ADS)

    Al-Milli, S.; Shaukat, A.; Spiteri, C.; Gao, Y.

    2014-04-01

    The main objective of the FASTER remote sensing system is the detection of rocks on planetary surfaces by employing models that can efficiently characterise rocks in terms of semantic descriptions. The proposed technique abates some of the algorithmic limitations of existing methods with no training requirements, lower computational complexity and greater robustness towards visual tracking applications over long-distance planetary terrains. Visual saliency models inspired from biological systems help to identify important regions (such as rocks) in the visual scene. Surface rocks are therefore completely described in terms of their local or global conspicuity pop-out characteristics. These local and global pop-out cues are (but not limited to); colour, depth, orientation, curvature, size, luminance intensity, shape, topology etc. The currently applied methods follow a purely bottom-up strategy of visual attention for selection of conspicuous regions in the visual scene without any topdown control. Furthermore the choice of models used (tested and evaluated) are relatively fast among the state-of-the-art and have very low computational load. Quantitative evaluation of these state-ofthe- art models was carried out using benchmark datasets including the Surrey Space Centre Lab Testbed, Pangu generated images, RAL Space SEEKER and CNES Mars Yard datasets. The analysis indicates that models based on visually salient information in the frequency domain (SRA, SDSR, PQFT) are the best performing ones for detecting rocks in an extra-terrestrial setting. In particular the SRA model seems to be the most optimum of the lot especially that it requires the least computational time while keeping errors competitively low. The salient objects extracted using these models can then be merged with the Digital Elevation Models (DEMs) generated from the same navigation cameras in order to be fused to the navigation map thus giving a clear indication of the rock locations.

  5. Fluorescence and visual detection of fluoride ions using a photoluminescent graphene oxide paper sensor

    NASA Astrophysics Data System (ADS)

    Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong

    2016-07-01

    The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02878k

  6. Fluorogenic Ag+–Tetrazolate Aggregation Enables Efficient Fluorescent Biological Silver Staining

    PubMed Central

    Xie, Sheng; Wong, Alex Y. H.; Kwok, Ryan T. K.; Li, Ying; Su, Huifang; Lam, Jacky W. Y.

    2018-01-01

    Abstract Silver staining, which exploits the special bioaffinity and the chromogenic reduction of silver ions, is an indispensable visualization method in biology. It is a most popular method for in‐gel protein detection. However, it is limited by run‐to‐run variability, background staining, inability for protein quantification, and limited compatibility with mass spectroscopic (MS) analysis; limitations that are largely attributed to the tricky chromogenic visualization. Herein, we reported a novel water‐soluble fluorogenic Ag+ probe, the sensing mechanism of which is based on an aggregation‐induced emission (AIE) process driven by tetrazolate‐Ag+ interactions. The fluorogenic sensing can substitute the chromogenic reaction, leading to a new fluorescence silver staining method. This new staining method offers sensitive detection of total proteins in polyacrylamide gels with a broad linear dynamic range and robust operations that rival the silver nitrate stain and the best fluorescent stains. PMID:29575702

  7. Visual-Vestibular Conflict Detection Depends on Fixation.

    PubMed

    Garzorz, Isabelle T; MacNeilage, Paul R

    2017-09-25

    Visual and vestibular signals are the primary sources of sensory information for self-motion. Conflict among these signals can be seriously debilitating, resulting in vertigo [1], inappropriate postural responses [2], and motion, simulator, or cyber sickness [3-8]. Despite this significance, the mechanisms mediating conflict detection are poorly understood. Here we model conflict detection simply as crossmodal discrimination with benchmark performance limited by variabilities of the signals being compared. In a series of psychophysical experiments conducted in a virtual reality motion simulator, we measure these variabilities and assess conflict detection relative to this benchmark. We also examine the impact of eye movements on visual-vestibular conflict detection. In one condition, observers fixate a point that is stationary in the simulated visual environment by rotating the eyes opposite head rotation, thereby nulling retinal image motion. In another condition, eye movement is artificially minimized via fixation of a head-fixed fixation point, thereby maximizing retinal image motion. Visual-vestibular integration performance is also measured, similar to previous studies [9-12]. We observe that there is a tradeoff between integration and conflict detection that is mediated by eye movements. Minimizing eye movements by fixating a head-fixed target leads to optimal integration but highly impaired conflict detection. Minimizing retinal motion by fixating a scene-fixed target improves conflict detection at the cost of impaired integration performance. The common tendency to fixate scene-fixed targets during self-motion [13] may indicate that conflict detection is typically a higher priority than the increase in precision of self-motion estimation that is obtained through integration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Image visualization of hyperspectral spectrum for LWIR

    NASA Astrophysics Data System (ADS)

    Chong, Eugene; Jeong, Young-Su; Lee, Jai-Hoon; Park, Dong Jo; Kim, Ju Hyun

    2015-07-01

    The image visualization of a real-time hyperspectral spectrum in the long-wave infrared (LWIR) range of 900-1450 cm-1 by a color-matching function is addressed. It is well known that the absorption spectra of main toxic industrial chemical (TIC) and chemical warfare agent (CWA) clouds are detected in this spectral region. Furthermore, a significant spectral peak due to various background species and unknown targets are also present. However, those are dismissed as noise, resulting in utilization limit. Herein, we applied a color-matching function that uses the information from hyperspectral data, which is emitted from the materials and surfaces of artificial or natural backgrounds in the LWIR region. This information was used to classify and differentiate the background signals from the targeted substances, and the results were visualized as image data without additional visual equipment. The tristimulus value based visualization information can quickly identify the background species and target in real-time detection in LWIR.

  9. [Long-term outcome of vitrectomy combined with internal limiting membrane peeling for idiopathic macular holes].

    PubMed

    Yamamoto, Kaori; Hori, Sadao

    2011-01-01

    To elucidate the long-term outcome of internal limiting membrane (ILM) peeling on visual function during vitrectomy for idiopathic macular holes using scanning laser ophthalmoscope (SLO) microperimetry. Prospective uncontrolled study. We studied 31 eyes (29 patients) with idiopathic macular holes. All patients underwent vitrectomy with ILM peeling. The SLO microperimetry was performed preoperatively, and once a year for 3 years postoperatively to detect scotomas in and around the macular holes, and both within and in close vicinity to the areas of ILM peeling. Closure of macular holes after one surgery was confirmed in all cases except for 2 with second surgery. The visual acuity by logarithmic minimum angle of resolution (logMAR) averaged 0.71 +/- 0.36 before surgery, 0.23 +/- 0.31 one year, 0.14 +/- 0.27 two years and 0.12 +/- 0.26 three years after surgery. There was significant improvement up to 2 years after the surgery. All scotomas detected before surgery in the holes, and 77.4% of those detected around the holes decreased gradually. No scotomas were detected in or around the area of ILM peeling either before or after surgery. ILM peeling in vitrectomy for idiopathic macular holes successfully improved visual acuity and did not influence retinal sensitivity in and around the area of ILM peeling. The scotomas detected in and around the holes before surgery gradually reduced or disappeared.

  10. Visual and surface plasmon resonance sensor for zirconium based on zirconium-induced aggregation of adenosine triphosphate-stabilized gold nanoparticles.

    PubMed

    Qi, Wenjing; Zhao, Jianming; Zhang, Wei; Liu, Zhongyuan; Xu, Min; Anjum, Saima; Majeed, Saadat; Xu, Guobao

    2013-07-17

    Owing to its high affinity with phosphate, Zr(IV) can induce the aggregation of adenosine 5'-triphosphate (ATP)-stabilized AuNPs, leading to the change of surface plasmon resonance (SPR) absorption spectra and color of ATP-stabilized AuNP solutions. Based on these phenomena, visual and SPR sensors for Zr(IV) have been developed for the first time. The A(660 nm)/A(518 nm) values of ATP-stabilized AuNPs in SPR absorption spectra increase linearly with the concentrations of Zr(IV) from 0.5 μM to 100 μM (r=0.9971) with a detection limit of 95 nM. A visual Zr(IV) detection is achieved with a detection limit of 30 μM. The sensor shows excellent selectivity against other metal ions, such as Cu(2+), Fe(3+), Cd(2+), and Pb(2+). The recoveries for the detection of 5 μM, 10 μM, 25 μM and 75 μM Zr(IV) in lake water samples are 96.0%, 97.0%, 95.6% and 102.4%, respectively. The recoveries of the proposed SPR method are comparable with those of ICP-OES method. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. The Development of Visual Short-Term Memory for Multifeature Items during Middle childhood

    ERIC Educational Resources Information Center

    Riggs, Kevin J.; Simpson, Andrew; Potts, Thomas

    2011-01-01

    Visual short-term memory (VSTM) research suggests that the adult capacity is limited to three or four multifeature object representations. Despite evidence supporting a developmental increase in capacity, it remains unclear what the unit of capacity is in children. The current study employed the change detection paradigm to investigate both the…

  12. Visual cognition in amnesic H.M.: selective deficits on the What's-Wrong-Here and Hidden-Figure tasks.

    PubMed

    MacKay, Donald G; James, Lori E

    2009-10-01

    Two experiments compared the visual cognition performance of amnesic H.M. and memory-normal controls matched for age, background, intelligence, and education. In Experiment 1 H.M. exhibited deficits relative to the controls in detecting "erroneous objects" in complex visual scenes--for example, a bird flying inside a fishbowl. In Experiment 2 H.M. exhibited deficits relative to the controls in standard Hidden-Figure tasks when detecting unfamiliar targets but not when detecting familiar targets--for example, circles, squares, and right-angle triangles. H.M.'s visual cognition deficits were not due to his well-known problems in explicit learning and recall, inability to comprehend or remember the instructions, general slowness, motoric difficulties, low motivation, low IQ relative to the controls, or working-memory limitations. Parallels between H.M.'s selective deficits in visual cognition, language, and memory are discussed. These parallels contradict the standard "systems theory" account of H.M.'s condition but comport with the hypothesis that H.M. has difficulty representing unfamiliar but not familiar information in visual cognition, language, and memory. Implications of our results are discussed for binding theory and the ongoing debate over what counts as "memory" versus "not-memory."

  13. Visual and Plasmon Resonance Absorption Sensor for Adenosine Triphosphate Based on the High Affinity between Phosphate and Zr(IV).

    PubMed

    Qi, Wenjing; Liu, Zhongyuan; Zhang, Wei; Halawa, Mohamed Ibrahim; Xu, Guobao

    2016-10-12

    Zr(IV) can form phosphate and Zr(IV) (-PO₃ 2- -Zr 4+ -) complex owing to the high affinity between Zr(IV) with phosphate. Zr(IV) can induce the aggregation of gold nanoparticles (AuNPs), while adenosine triphosphate(ATP) can prevent Zr(IV)-induced aggregation of AuNPs. Herein, a visual and plasmon resonance absorption (PRA)sensor for ATP have been developed using AuNPs based on the high affinity between Zr(IV)with ATP. AuNPs get aggregated in the presence of certain concentrations of Zr(IV). After the addition of ATP, ATP reacts with Zr(IV) and prevents AuNPs from aggregation, enabling the detection of ATP. Because of the fast interaction of ATP with Zr(IV), ATP can be detected with a detection limit of 0.5 μM within 2 min by the naked eye. Moreover, ATP can be detected by the PRA technique with higher sensitivity. The A 520nm / A 650nm values in PRA spectra increase linearly with the concentrations of ATP from 0.1 μM to 15 μM (r = 0.9945) with a detection limit of 28 nM. The proposed visual and PRA sensor exhibit good selectivity against adenosine, adenosine monophosphate, guanosine triphosphate, cytidine triphosphate and uridine triphosphate. The recoveries for the analysis of ATP in synthetic samples range from 95.3% to 102.0%. Therefore, the proposed novel sensor for ATP is promising for real-time or on-site detection of ATP.

  14. Multiple-object permanence tracking: limitation in maintenance and transformation of perceptual objects.

    PubMed

    Saiki, Jun

    2002-01-01

    Research on change blindness and transsaccadic memory revealed that a limited amount of information is retained across visual disruptions in visual working memory. It has been proposed that visual working memory can hold four to five coherent object representations. To investigate their maintenance and transformation in dynamic situations, I devised an experimental paradigm called multiple-object permanence tracking (MOPT) that measures memory for multiple feature-location bindings in dynamic situations. Observers were asked to detect any color switch in the middle of a regular rotation of a pattern with multiple colored disks behind an occluder. The color-switch detection performance dramatically declined as the pattern rotation velocity increased, and this effect of object motion was independent of the number of targets. The MOPT task with various shapes and colors showed that color-shape conjunctions are not available in the MOPT task. These results suggest that even completely predictable motion severely reduces our capacity of object representations, from four to only one or two.

  15. Contingent capture of involuntary visual attention interferes with detection of auditory stimuli

    PubMed Central

    Kamke, Marc R.; Harris, Jill

    2014-01-01

    The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color). In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy) more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality. PMID:24920945

  16. Contingent capture of involuntary visual attention interferes with detection of auditory stimuli.

    PubMed

    Kamke, Marc R; Harris, Jill

    2014-01-01

    The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color). In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy) more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality.

  17. Microstimulation of area V4 has little effect on spatial attention and on perception of phosphenes evoked in area V1

    PubMed Central

    Dagnino, Bruno; Gariel-Mathis, Marie-Alice

    2014-01-01

    Previous transcranial magnetic stimulation (TMS) studies suggested that feedback from higher to lower areas of the visual cortex is important for the access of visual information to awareness. However, the influence of cortico-cortical feedback on awareness and the nature of the feedback effects are not yet completely understood. In the present study, we used electrical microstimulation in the visual cortex of monkeys to test the hypothesis that cortico-cortical feedback plays a role in visual awareness. We investigated the interactions between the primary visual cortex (V1) and area V4 by applying microstimulation in both cortical areas at various delays. We report that the monkeys detected the phosphenes produced by V1 microstimulation but subthreshold V4 microstimulation did not influence V1 phosphene detection thresholds. A second experiment examined the influence of V4 microstimulation on the monkeys' ability to detect the dimming of one of three peripheral visual stimuli. Again, microstimulation of a group of V4 neurons failed to modulate the monkeys' perception of a stimulus in their receptive field. We conclude that conditions exist where microstimulation of area V4 has only a limited influence on visual perception. PMID:25392172

  18. Microstimulation of area V4 has little effect on spatial attention and on perception of phosphenes evoked in area V1.

    PubMed

    Dagnino, Bruno; Gariel-Mathis, Marie-Alice; Roelfsema, Pieter R

    2015-02-01

    Previous transcranial magnetic stimulation (TMS) studies suggested that feedback from higher to lower areas of the visual cortex is important for the access of visual information to awareness. However, the influence of cortico-cortical feedback on awareness and the nature of the feedback effects are not yet completely understood. In the present study, we used electrical microstimulation in the visual cortex of monkeys to test the hypothesis that cortico-cortical feedback plays a role in visual awareness. We investigated the interactions between the primary visual cortex (V1) and area V4 by applying microstimulation in both cortical areas at various delays. We report that the monkeys detected the phosphenes produced by V1 microstimulation but subthreshold V4 microstimulation did not influence V1 phosphene detection thresholds. A second experiment examined the influence of V4 microstimulation on the monkeys' ability to detect the dimming of one of three peripheral visual stimuli. Again, microstimulation of a group of V4 neurons failed to modulate the monkeys' perception of a stimulus in their receptive field. We conclude that conditions exist where microstimulation of area V4 has only a limited influence on visual perception. Copyright © 2015 the American Physiological Society.

  19. Two visual systems in monitoring of dynamic traffic: effects of visual disruption.

    PubMed

    Zheng, Xianjun Sam; McConkie, George W

    2010-05-01

    Studies from neurophysiology and neuropsychology provide support for two separate object- and location-based visual systems, ventral and dorsal. In the driving context, a study was conducted using a change detection paradigm to explore drivers' ability to monitor the dynamic traffic flow, and the effects of visual disruption on these two visual systems. While driving, a discrete change, such as vehicle location, color, or identity, was occasionally made in one of the vehicles on the road ahead of the driver. Experiment results show that without visual disruption, all changes were detected very well; yet, these equally perceivable changes were disrupted differently by a brief blank display (150 ms): the detection of location changes was especially reduced. The disruption effects were also bigger for the parked vehicle compared to the moving ones. The findings support the different roles for two visual systems in monitoring the dynamic traffic: the "where", dorsal system, tracks vehicle spatiotemporal information on perceptual level, encoding information in a coarse and transient manner; whereas the "what", ventral system, monitors vehicles' featural information, encoding information more accurately and robustly. Both systems work together contributing to the driver's situation awareness of traffic. Benefits and limitations of using the driving simulation are also discussed. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  20. Genovar: a detection and visualization tool for genomic variants.

    PubMed

    Jung, Kwang Su; Moon, Sanghoon; Kim, Young Jin; Kim, Bong-Jo; Park, Kiejung

    2012-05-08

    Along with single nucleotide polymorphisms (SNPs), copy number variation (CNV) is considered an important source of genetic variation associated with disease susceptibility. Despite the importance of CNV, the tools currently available for its analysis often produce false positive results due to limitations such as low resolution of array platforms, platform specificity, and the type of CNV. To resolve this problem, spurious signals must be separated from true signals by visual inspection. None of the previously reported CNV analysis tools support this function and the simultaneous visualization of comparative genomic hybridization arrays (aCGH) and sequence alignment. The purpose of the present study was to develop a useful program for the efficient detection and visualization of CNV regions that enables the manual exclusion of erroneous signals. A JAVA-based stand-alone program called Genovar was developed. To ascertain whether a detected CNV region is a novel variant, Genovar compares the detected CNV regions with previously reported CNV regions using the Database of Genomic Variants (DGV, http://projects.tcag.ca/variation) and the Single Nucleotide Polymorphism Database (dbSNP). The current version of Genovar is capable of visualizing genomic data from sources such as the aCGH data file and sequence alignment format files. Genovar is freely accessible and provides a user-friendly graphic user interface (GUI) to facilitate the detection of CNV regions. The program also provides comprehensive information to help in the elimination of spurious signals by visual inspection, making Genovar a valuable tool for reducing false positive CNV results. http://genovar.sourceforge.net/.

  1. Fluorescence and visual detection of fluoride ions using a photoluminescent graphene oxide paper sensor.

    PubMed

    Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong

    2016-07-14

    The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F(-) on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F(-) can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F(-) in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F(-) has been successfully developed. The paper sensor showed high sensitivity for aqueous F(-), and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.

  2. Target-responsive DNAzyme cross-linked hydrogel for visual quantitative detection of lead.

    PubMed

    Huang, Yishun; Ma, Yanli; Chen, Yahong; Wu, Xuemeng; Fang, Luting; Zhu, Zhi; Yang, Chaoyong James

    2014-11-18

    Because of the severe health risks associated with lead pollution, rapid, sensitive, and portable detection of low levels of Pb(2+) in biological and environmental samples is of great importance. In this work, a Pb(2+)-responsive hydrogel was prepared using a DNAzyme and its substrate as cross-linker for rapid, sensitive, portable, and quantitative detection of Pb(2+). Gold nanoparticles (AuNPs) were first encapsulated in the hydrogel as an indicator for colorimetric analysis. In the absence of lead, the DNAzyme is inactive, and the substrate cross-linker maintains the hydrogel in the gel form. In contrast, the presence of lead activates the DNAzyme to cleave the substrate, decreasing the cross-linking density of the hydrogel and resulting in dissolution of the hydrogel and release of AuNPs for visual detection. As low as 10 nM Pb(2+) can be detected by the naked eye. Furthermore, to realize quantitative visual detection, a volumetric bar-chart chip (V-chip) was used for quantitative readout of the hydrogel system by replacing AuNPs with gold-platinum core-shell nanoparticles (Au@PtNPs). The Au@PtNPs released from the hydrogel upon target activation can efficiently catalyze the decomposition of H2O2 to generate a large volume of O2. The gas pressure moves an ink bar in the V-chip for portable visual quantitative detection of lead with a detection limit less than 5 nM. The device was able to detect lead in digested blood with excellent accuracy. The method developed can be used for portable lead quantitation in many applications. Furthermore, the method can be further extended to portable visual quantitative detection of a variety of targets by replacing the lead-responsive DNAzyme with other DNAzymes.

  3. Filtrates and Residues: Spectrophotometry: Mechanics and Measurement.

    ERIC Educational Resources Information Center

    Diehl-Jones, Susan M.

    1984-01-01

    Provided are experiments to acquaint students with basic spectrophotometer components and their functions, to use the instrument in an openended-experiment, and to use Beer's Law in several different ways. In addition, the detectability (tolerance) of the spectrophotometer with visual detection limits is provided as an optional activity. (JN)

  4. Metacognitive monitoring and control in visual change detection: Implications for situation awareness and cognitive control

    PubMed Central

    McAnally, Ken I.; Morris, Adam P.; Best, Christopher

    2017-01-01

    Metacognitive monitoring and control of situation awareness (SA) are important for a range of safety-critical roles (e.g., air traffic control, military command and control). We examined the factors affecting these processes using a visual change detection task that included representative tactical displays. SA was assessed by asking novice observers to detect changes to a tactical display. Metacognitive monitoring was assessed by asking observers to estimate the probability that they would correctly detect a change, either after study of the display and before the change (judgement of learning; JOL) or after the change and detection response (judgement of performance; JOP). In Experiment 1, observers failed to detect some changes to the display, indicating imperfect SA, but JOPs were reasonably well calibrated to objective performance. Experiment 2 examined JOLs and JOPs in two task contexts: with study-time limits imposed by the task or with self-pacing to meet specified performance targets. JOPs were well calibrated in both conditions as were JOLs for high performance targets. In summary, observers had limited SA, but good insight about their performance and learning for high performance targets and allocated study time appropriately. PMID:28915244

  5. Adaptation of a visualized loop-mediated isothermal amplification technique for field detection of Plasmodium vivax infection.

    PubMed

    Tao, Zhi-Yong; Zhou, Hua-Yun; Xia, Hui; Xu, Sui; Zhu, Han-Wu; Culleton, Richard L; Han, Eun-Taek; Lu, Feng; Fang, Qiang; Gu, Ya-Ping; Liu, Yao-Bao; Zhu, Guo-Ding; Wang, Wei-Ming; Li, Ju-Lin; Cao, Jun; Gao, Qi

    2011-06-21

    Loop-mediated isothermal amplification (LAMP) is a high performance method for detecting DNA and holds promise for use in the molecular detection of infectious pathogens, including Plasmodium spp. However, in most malaria-endemic areas, which are often resource-limited, current LAMP methods are not feasible for diagnosis due to difficulties in accurately interpreting results with problems of sensitive visualization of amplified products, and the risk of contamination resulting from the high quantity of amplified DNA produced. In this study, we establish a novel visualized LAMP method in a closed-tube system, and validate it for the diagnosis of malaria under simulated field conditions. A visualized LAMP method was established by the addition of a microcrystalline wax-dye capsule containing the highly sensitive DNA fluorescence dye SYBR Green I to a normal LAMP reaction prior to the initiation of the reaction. A total of 89 blood samples were collected on filter paper and processed using a simple boiling method for DNA extraction, and then tested by the visualized LAMP method for Plasmodium vivax infection. The wax capsule remained intact during isothermal amplification, and released the DNA dye to the reaction mixture only when the temperature was raised to the melting point following amplification. Soon after cooling down, the solidified wax sealed the reaction mix at the bottom of the tube, thus minimizing the risk of aerosol contamination. Compared to microscopy, the sensitivity and specificity of LAMP were 98.3% (95% confidence interval (CI): 91.1-99.7%) and 100% (95% CI: 88.3-100%), and were in close agreement with a nested polymerase chain reaction method. This novel, cheap and quick visualized LAMP method is feasible for malaria diagnosis in resource-limited field settings.

  6. The development of real-time stability supports visual working memory performance: Young children's feature binding can be improved through perceptual structure.

    PubMed

    Simmering, Vanessa R; Wood, Chelsey M

    2017-08-01

    Working memory is a basic cognitive process that predicts higher-level skills. A central question in theories of working memory development is the generality of the mechanisms proposed to explain improvements in performance. Prior theories have been closely tied to particular tasks and/or age groups, limiting their generalizability. The cognitive dynamics theory of visual working memory development has been proposed to overcome this limitation. From this perspective, developmental improvements arise through the coordination of cognitive processes to meet demands of different behavioral tasks. This notion is described as real-time stability, and can be probed through experiments that assess how changing task demands impact children's performance. The current studies test this account by probing visual working memory for colors and shapes in a change detection task that compares detection of changes to new features versus swaps in color-shape binding. In Experiment 1, 3- to 4-year-old children showed impairments specific to binding swaps, as predicted by decreased real-time stability early in development; 5- to 6-year-old children showed a slight advantage on binding swaps, but 7- to 8-year-old children and adults showed no difference across trial types. Experiment 2 tested the proposed explanation of young children's binding impairment through added perceptual structure, which supported the stability and precision of feature localization in memory-a process key to detecting binding swaps. This additional structure improved young children's binding swap detection, but not new-feature detection or adults' performance. These results provide further evidence for the cognitive dynamics and real-time stability explanation of visual working memory development. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Detailed sensory memory, sloppy working memory.

    PubMed

    Sligte, Ilja G; Vandenbroucke, Annelinde R E; Scholte, H Steven; Lamme, Victor A F

    2010-01-01

    Visual short-term memory (VSTM) enables us to actively maintain information in mind for a brief period of time after stimulus disappearance. According to recent studies, VSTM consists of three stages - iconic memory, fragile VSTM, and visual working memory - with increasingly stricter capacity limits and progressively longer lifetimes. Still, the resolution (or amount of visual detail) of each VSTM stage has remained unexplored and we test this in the present study. We presented people with a change detection task that measures the capacity of all three forms of VSTM, and we added an identification display after each change trial that required people to identify the "pre-change" object. Accurate change detection plus pre-change identification requires subjects to have a high-resolution representation of the "pre-change" object, whereas change detection or identification only can be based on the hunch that something has changed, without exactly knowing what was presented before. We observed that people maintained 6.1 objects in iconic memory, 4.6 objects in fragile VSTM, and 2.1 objects in visual working memory. Moreover, when people detected the change, they could also identify the pre-change object on 88% of the iconic memory trials, on 71% of the fragile VSTM trials and merely on 53% of the visual working memory trials. This suggests that people maintain many high-resolution representations in iconic memory and fragile VSTM, but only one high-resolution object representation in visual working memory.

  8. A simple 96 well microfluidic chip combined with visual and densitometry detection for resource-poor point of care testing

    PubMed Central

    Yang, Minghui; Sun, Steven; Kostov, Yordan

    2010-01-01

    There is a well-recognized need for low cost biodetection technologies for resource-poor settings with minimal medical infrastructure. Lab-on-a-chip (LOC) technology has the ability to perform biological assays in such settings. The aim of this work is to develop a low cost, high-throughput detection system for the analysis of 96 samples simultaneously outside the laboratory setting. To achieve this aim, several biosensing elements were combined: a syringe operated ELISA lab-on-a-chip (ELISA-LOC) which integrates fluid delivery system into a miniature 96-well plate; a simplified non-enzymatic reporter and detection approach using a gold nanoparticle-antibody conjugate as a secondary antibody and silver enhancement of the visual signal; and Carbon nanotubes (CNT) to increase primary antibody immobilization and improve assay sensitivity. Combined, these elements obviate the need for an ELISA washer, electrical power for operation and a sophisticated detector. We demonstrate the use of the device for detection of Staphylococcal enterotoxin B, a major foodborne toxin using three modes of detection, visual detection, CCD camera and document scanner. With visual detection or using a document scanner to measure the signal, the limit of detection (LOD) was 0.5ng/ml. In addition to visual detection, for precise quantitation of signal using densitometry and a CCD camera, the LOD was 0.1ng/ml for the CCD analysis and 0.5 ng/ml for the document scanner. The observed sensitivity is in the same range as laboratory-based ELISA testing. The point of care device can analyze 96 samples simultaneously, permitting high throughput diagnostics in the field and in resource poor areas without ready access to laboratory facilities or electricity. PMID:21503269

  9. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    PubMed

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  10. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes

    PubMed Central

    French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-01-01

    Background Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Objective Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. Methods We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Results Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Conclusions Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org. PMID:27146002

  11. Visual and Plasmon Resonance Absorption Sensor for Adenosine Triphosphate Based on the High Affinity between Phosphate and Zr(IV)

    PubMed Central

    Qi, Wenjing; Liu, Zhongyuan; Zhang, Wei; Halawa, Mohamed Ibrahim; Xu, Guobao

    2016-01-01

    Zr(IV) can form phosphate and Zr(IV) (–PO32−–Zr4+–) complex owing to the high affinity between Zr(IV) with phosphate. Zr(IV) can induce the aggregation of gold nanoparticles (AuNPs), while adenosine triphosphate(ATP) can prevent Zr(IV)-induced aggregation of AuNPs. Herein, a visual and plasmon resonance absorption (PRA)sensor for ATP have been developed using AuNPs based on the high affinity between Zr(IV)with ATP. AuNPs get aggregated in the presence of certain concentrations of Zr(IV). After the addition of ATP, ATP reacts with Zr(IV) and prevents AuNPs from aggregation, enabling the detection of ATP. Because of the fast interaction of ATP with Zr(IV), ATP can be detected with a detection limit of 0.5 μM within 2 min by the naked eye. Moreover, ATP can be detected by the PRA technique with higher sensitivity. The A520nm/A650nm values in PRA spectra increase linearly with the concentrations of ATP from 0.1 μM to 15 μM (r = 0.9945) with a detection limit of 28 nM. The proposed visual and PRA sensor exhibit good selectivity against adenosine, adenosine monophosphate, guanosine triphosphate, cytidine triphosphate and uridine triphosphate. The recoveries for the analysis of ATP in synthetic samples range from 95.3% to 102.0%. Therefore, the proposed novel sensor for ATP is promising for real-time or on-site detection of ATP. PMID:27754349

  12. Saliency Detection of Stereoscopic 3D Images with Application to Visual Discomfort Prediction

    NASA Astrophysics Data System (ADS)

    Li, Hong; Luo, Ting; Xu, Haiyong

    2017-06-01

    Visual saliency detection is potentially useful for a wide range of applications in image processing and computer vision fields. This paper proposes a novel bottom-up saliency detection approach for stereoscopic 3D (S3D) images based on regional covariance matrix. As for S3D saliency detection, besides the traditional 2D low-level visual features, additional 3D depth features should also be considered. However, only limited efforts have been made to investigate how different features (e.g. 2D and 3D features) contribute to the overall saliency of S3D images. The main contribution of this paper is that we introduce a nonlinear feature integration descriptor, i.e., regional covariance matrix, to fuse both 2D and 3D features for S3D saliency detection. The regional covariance matrix is shown to be effective for nonlinear feature integration by modelling the inter-correlation of different feature dimensions. Experimental results demonstrate that the proposed approach outperforms several existing relevant models including 2D extended and pure 3D saliency models. In addition, we also experimentally verified that the proposed S3D saliency map can significantly improve the prediction accuracy of experienced visual discomfort when viewing S3D images.

  13. Visual and sensitive fluorescent sensing for ultratrace mercury ions by perovskite quantum dots.

    PubMed

    Lu, Li-Qiang; Tan, Tian; Tian, Xi-Ke; Li, Yong; Deng, Pan

    2017-09-15

    Mercury ions sensing is an important issue for human health and environmental safety. A novel fluorescence nanosensor was designed for rapid visual detection of ultratrace mercury ions (Hg 2+ ) by using CH 3 NH 3 PbBr 3 perovskite quantum dots (QDs) based on the surface ion-exchange mechanism. The synthesized CH 3 NH 3 PbBr 3 QDs can emitt intense green fluorescence with high quantum yield of 50.28%, and can be applied for Hg 2+ sensing with the detection limit of 0.124 nM (24.87 ppt) in the range of 0 nM-100 nM. Furthermore, the interfering metal ions have no any influence on the fluorescence intensity of QDs, showing the perovskite QDs possess the high selectivity and sensitivity for Hg 2+ detection. The sensing mechanism of perovskite QDs for Hg 2+ is has also been investigated by XPS, EDX studies, showing Pb 2+ on the surface of perovskite QDs has been partially replaced by Hg 2+ . Spot plate test shows that the perovskite QDs can also be used for visual detection of Hg 2+ . Our research indicated the perovskite QDs are promising candidates for the visual fluorescence detection of environmental micropollutants. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Attention to Attributes and Objects in Working Memory

    ERIC Educational Resources Information Center

    Cowan, Nelson; Blume, Christopher L.; Saults, J. Scott

    2013-01-01

    It has been debated on the basis of change-detection procedures whether visual working memory is limited by the number of objects, task-relevant attributes within those objects, or bindings between attributes. This debate, however, has been hampered by several limitations, including the use of conditions that vary between studies and the absence…

  15. Visual endpoint detection of Escherichia coli O157:H7 using isothermal Genome Exponential Amplification Reaction (GEAR) assay and malachite green.

    PubMed

    Jothikumar, Prithiviraj; Narayanan, Jothikumar; Hill, Vincent R

    2014-03-01

    Rapid and specific detection methods for bacterial agents in drinking water are important for disease prevention and responding to suspected contamination events. In this study, an isothermal Genome Exponential Amplification Reaction (GEAR) assay for Escherichia coli O157:H7 was designed specifically to recognize a 199-bp fragment of the lipopolysaccharide gene (rfbE) for rapid testing of water samples. The GEAR assay was found to be specific for E. coli O157:H7 using 10 isolates of E. coli O157:H7 and a panel of 86 bacterial controls. The GEAR assay was performed at a constant temperature of 65°C using SYTO 9 intercalating dye. Detection limits were determined to be 20 CFU for the GEAR assay. When SYTO 9 fluorescence was measured using a real-time PCR instrument, the assay had the same detection limit as when malachite green was added to the reaction mix and a characteristic blue color was visually observed in positive reactions. The study also found that 50 and 20 CFU of E. coli O157:H7 seeded into 100-liter of tap water could be detected by the GEAR assays after the sample was concentrated by hollow-fiber ultrafiltration (HFUF) and approximately 10% of HFUF concentrate was cultured using trypticase soy broth-novobiocin. When applied to 19 surface water samples collected from Tennessee and Kentucky, the GEAR assay and a published real-time PCR assay both detected E. coli O157:H7 in two of the samples. The results of this study indicate that the GEAR assay can be sensitive for rapid detection of E. coli O157:H7 in water samples using fluorometric instruments and visual endpoint determination. Published by Elsevier B.V.

  16. Aneurysm Recurrence Volumetry Is More Sensitive than Visual Evaluation of Aneurysm Recurrences.

    PubMed

    Schönfeld, M H; Schlotfeldt, V; Forkert, N D; Goebell, E; Groth, M; Vettorazzi, E; Cho, Y D; Han, M H; Kang, H-S; Fiehler, J

    2016-03-01

    Considerable inter-observer variability in the visual assessment of aneurysm recurrences limits its use as an outcome parameter evaluating new coil generations. The purpose of this study was to compare visual assessment of aneurysm recurrences and aneurysm recurrence volumetry with an example dataset of HydroSoft coils (HSC) versus bare platinum coils (BPC). For this retrospective study, 3-dimensional time-of-flight magnetic resonance angiography datasets acquired 6 and 12 months after endovascular therapy using BPC only or mainly HSC were analyzed. Aneurysm recurrence volumes were visually rated by two observersas well as quantified by subtraction of the datasets after intensity-based rigid registration. A total of 297 aneurysms were analyzed (BPC: 169, HSC: 128). Recurrences were detected by aneurysm recurrence volumetry in 9 of 128 (7.0 %) treated with HSC and in 24 of 169 (14.2 %) treated with BPC (odds ratio: 2.39, 95 % confidence interval: 1.05-5.48; P = 0.039). Aneurysm recurrence volumetry revealed an excellent correlation between observers (Cronbach's alpha = 0.93). In contrast, no significant difference in aneurysm recurrence was found for visual assessment (3.9 % in HSC cases and 4.7 % in BPC cases). Recurrences were observed in aneurysms smaller than the sample median in 10 of 33 (30.3 %) by aneurysm recurrence volumetry and in 1 of 13 (7.7 %) by visual assessment. Aneurysm recurrences were detected more frequently by aneurysm recurrence volumetry when compared with visual assessment. By using aneurysm recurrence volumetry, differences between treatment groups were detected with higher sensitivity and inter-observer validity probably because of the higher detection rate of recurrences in small aneurysms.

  17. What you see is what you expect: rapid scene understanding benefits from prior experience.

    PubMed

    Greene, Michelle R; Botros, Abraham P; Beck, Diane M; Fei-Fei, Li

    2015-05-01

    Although we are able to rapidly understand novel scene images, little is known about the mechanisms that support this ability. Theories of optimal coding assert that prior visual experience can be used to ease the computational burden of visual processing. A consequence of this idea is that more probable visual inputs should be facilitated relative to more unlikely stimuli. In three experiments, we compared the perceptions of highly improbable real-world scenes (e.g., an underwater press conference) with common images matched for visual and semantic features. Although the two groups of images could not be distinguished by their low-level visual features, we found profound deficits related to the improbable images: Observers wrote poorer descriptions of these images (Exp. 1), had difficulties classifying the images as unusual (Exp. 2), and even had lower sensitivity to detect these images in noise than to detect their more probable counterparts (Exp. 3). Taken together, these results place a limit on our abilities for rapid scene perception and suggest that perception is facilitated by prior visual experience.

  18. A systematic comparison between visual cues for boundary detection.

    PubMed

    Mély, David A; Kim, Junkyung; McGill, Mason; Guo, Yuliang; Serre, Thomas

    2016-03-01

    The detection of object boundaries is a critical first step for many visual processing tasks. Multiple cues (we consider luminance, color, motion and binocular disparity) available in the early visual system may signal object boundaries but little is known about their relative diagnosticity and how to optimally combine them for boundary detection. This study thus aims at understanding how early visual processes inform boundary detection in natural scenes. We collected color binocular video sequences of natural scenes to construct a video database. Each scene was annotated with two full sets of ground-truth contours (one set limited to object boundaries and another set which included all edges). We implemented an integrated computational model of early vision that spans all considered cues, and then assessed their diagnosticity by training machine learning classifiers on individual channels. Color and luminance were found to be most diagnostic while stereo and motion were least. Combining all cues yielded a significant improvement in accuracy beyond that of any cue in isolation. Furthermore, the accuracy of individual cues was found to be a poor predictor of their unique contribution for the combination. This result suggested a complex interaction between cues, which we further quantified using regularization techniques. Our systematic assessment of the accuracy of early vision models for boundary detection together with the resulting annotated video dataset should provide a useful benchmark towards the development of higher-level models of visual processing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Semi-quantitative visual detection of loop mediated isothermal amplification (LAMP)-generated DNA by distance-based measurement on a paper device.

    PubMed

    Hongwarittorrn, Irin; Chaichanawongsaroj, Nuntaree; Laiwattanapaisal, Wanida

    2017-12-01

    A distance-based paper analytical device (dPAD) for loop mediated isothermal amplification (LAMP) detection based on distance measurement was proposed. This approach relied on visual detection by the length of colour developed on the dPAD with reference to semi-quantitative determination of the initial amount of genomic DNA. In this communication, E. coli DNA was chosen as a template DNA for LAMP reaction. In accordance with the principle, the dPAD was immobilized by polyethylenimine (PEI), which is a strong cationic polymer, in the hydrophilic channel of the paper device. Hydroxynaphthol blue (HNB), a colourimetric indicator for monitoring the change of magnesium ion concentration in the LAMP reaction, was used to react with the immobilized PEI. The positive charges of PEI react with the negative charges of free HNB in the LAMP reaction, producing a blue colour deposit on the paper device. Consequently, the apparently visual distance appeared within 5min and length of distance correlated to the amount of DNA in the sample. The distance-based PAD for the visual detection of the LAMP reaction could quantify the initial concentration of genomic DNA as low as 4.14 × 10 3 copiesµL -1 . This distance-based visual semi-quantitative platform is suitable for choice of LAMP detection method, particular in resource-limited settings because of the advantages of low cost, simple fabrication and operation, disposability and portable detection of the dPAD device. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Visual acuity of the honey bee retina and the limits for feature detection.

    PubMed

    Rigosi, Elisa; Wiederman, Steven D; O'Carroll, David C

    2017-04-06

    Visual abilities of the honey bee have been studied for more than 100 years, recently revealing unexpectedly sophisticated cognitive skills rivalling those of vertebrates. However, the physiological limits of the honey bee eye have been largely unaddressed and only studied in an unnatural, dark state. Using a bright display and intracellular recordings, we here systematically investigated the angular sensitivity across the light adapted eye of honey bee foragers. Angular sensitivity is a measure of photoreceptor receptive field size and thus small values indicate higher visual acuity. Our recordings reveal a fronto-ventral acute zone in which angular sensitivity falls below 1.9°, some 30% smaller than previously reported. By measuring receptor noise and responses to moving dark objects, we also obtained direct measures of the smallest features detectable by the retina. In the frontal eye, single photoreceptors respond to objects as small as 0.6° × 0.6°, with >99% reliability. This indicates that honey bee foragers possess significantly better resolution than previously reported or estimated behaviourally, and commonly assumed in modelling of bee acuity.

  1. [Adaptive optics for ophthalmology].

    PubMed

    Saleh, M

    2016-04-01

    Adaptive optics is a technology enhancing the visual performance of an optical system by correcting its optical aberrations. Adaptive optics have already enabled several breakthroughs in the field of visual sciences, such as improvement of visual acuity in normal and diseased eyes beyond physiologic limits, and the correction of presbyopia. Adaptive optics technology also provides high-resolution, in vivo imaging of the retina that may eventually help to detect the onset of retinal conditions at an early stage and provide better assessment of treatment efficacy. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Visual detection of trace nitroaromatic explosive residue using photoluminescent metallole-containing polymers.

    PubMed

    Toal, Sarah J; Sanchez, Jason C; Dugan, Regina E; Trogler, William C

    2007-01-01

    The detection of trace explosives is important for forensic, military, and homeland security applications. Detection of widely used nitroaromatic explosives (trinitrotoluene [TNT], 2,4-dinitrotoluene [DNT], picric acid [PA]) was carried out using photoluminescent metallole-containing polymers. The method of detection is through the quenching of fluorescence of thin films of the polymer, prepared by spray coating organic solutions of the polymer, by the explosive analyte. Visual quenching of luminescence (lambda(em) approximately 400-510 nm) in the presence of the explosive is seen immediately upon illumination with near-UV light (lambda(ex)=360 nm). Detection limits were observed to be as low as 5 ng for TNT, 20 ng for DNT, and 5 ng for PA. In addition, experiments with normal production line explosives and their components show that this technology is also able to detect composition B, Pyrodex, and nitromethane. This method offers a convenient and sensitive method of detection of trace nitroaromatic explosive residue.

  3. Luminol functionalized gold nanoparticles as colorimetric and chemiluminescent probes for visual, label free, highly sensitive and selective detection of minocycline

    NASA Astrophysics Data System (ADS)

    He, Yi; Peng, Rufang

    2014-11-01

    In this work, luminol functionalized gold nanoparticles (LuAuNPs) were used as colorimetric and chemiluminescent probes for visual, label free, sensitive and selective detection of minocycline (MC). The LuAuNPs were prepared by simple one-pot reduction of HAuCl4 with luminol, which exhibited a good chemiluminescence (CL) activity owing to the presence of luminol molecules on their surface and surface plasmon resonance absorption. In the absence of MC, the color of LuAuNPs was wine red and their size was relatively small (˜25 nm), which could react with silver nitrate, producing a strong CL emission. Upon the addition of MC at acidic buffer solutions, the electrostatic interaction between positively charged MC and negatively charged LuAuNPs caused the aggregation of LuAuNPs, generating a purple or blue color. Simultaneously, the aggregated LuAuNPs did not effectively react with silver nitrate, producing a weak CL emission. The signal change was linearly dependent on the logarithm of MC concentration in the range from 30 ng to 1.0 μg for colorimetric detection and from 10 ng to 1.0 μg for CL detection. With colorimetry, a detection limit of 22 ng was achieved, while the detection limit for CL detection modality was 9.7 ng.

  4. A direct detection of Escherichia coli genomic DNA using gold nanoprobes

    PubMed Central

    2012-01-01

    Background In situation like diagnosis of clinical and forensic samples there exists a need for highly sensitive, rapid and specific DNA detection methods. Though conventional DNA amplification using PCR can provide fast results, it is not widely practised in diagnostic laboratories partially because it requires skilled personnel and expensive equipment. To overcome these limitations nanoparticles have been explored as signalling probes for ultrasensitive DNA detection that can be used in field applications. Among the nanomaterials, gold nanoparticles (AuNPs) have been extensively used mainly because of its optical property and ability to get functionalized with a variety of biomolecules. Results We report a protocol for the use of gold nanoparticles functionalized with single stranded oligonucleotide (AuNP- oligo probe) as visual detection probes for rapid and specific detection of Escherichia coli. The AuNP- oligo probe on hybridization with target DNA containing complementary sequences remains red whereas test samples without complementary DNA sequences to the probe turns purple due to acid induced aggregation of AuNP- oligo probes. The color change of the solution is observed visually by naked eye demonstrating direct and rapid detection of the pathogenic Escherichia coli from its genomic DNA without the need for PCR amplification. The limit of detection was ~54 ng for unamplified genomic DNA. The method requires less than 30 minutes to complete after genomic DNA extraction. However, by using unamplified enzymatic digested genomic DNA, the detection limit of 11.4 ng was attained. Results of UV-Vis spectroscopic measurement and AFM imaging further support the hypothesis of aggregation based visual discrimination. To elucidate its utility in medical diagnostic, the assay was validated on clinical strains of pathogenic Escherichia coli obtained from local hospitals and spiked urine samples. It was found to be 100% sensitive and proves to be highly specific without any cross reaction with non-Escherichia coli strains. Conclusion This work gives entry into a new class of DNA/gold nanoparticles hybrid materials which might have optical property that can be controlled for application in diagnostics. We note that it should be possible to extend this strategy easily for developing new types of DNA biosensor for point of care detection. The salient feature of this approach includes low-cost, robust reagents and simple colorimetric detection of pathogen. PMID:22309695

  5. Reduced change blindness suggests enhanced attention to detail in individuals with autism.

    PubMed

    Smith, Hayley; Milne, Elizabeth

    2009-03-01

    The phenomenon of change blindness illustrates that a limited number of items within the visual scene are attended to at any one time. It has been suggested that individuals with autism focus attention on less contextually relevant aspects of the visual scene, show superior perceptual discrimination and notice details which are often ignored by typical observers. In this study we investigated change blindness in autism by asking participants to detect continuity errors deliberately introduced into a short film. Whether the continuity errors involved central/marginal or social/non-social aspects of the visual scene was varied. Thirty adolescent participants, 15 with autistic spectrum disorder (ASD) and 15 typically developing (TD) controls participated. The participants with ASD detected significantly more errors than the TD participants. Both groups identified more errors involving central rather than marginal aspects of the scene, although this effect was larger in the TD participants. There was no difference in the number of social or non-social errors detected by either group of participants. In line with previous data suggesting an abnormally broad attentional spotlight and enhanced perceptual function in individuals with ASD, the results of this study suggest enhanced awareness of the visual scene in ASD. The results of this study could reflect superior top-down control of visual search in autism, enhanced perceptual function, or inefficient filtering of visual information in ASD.

  6. A biological hierarchical model based underwater moving object detection.

    PubMed

    Shen, Jie; Fan, Tanghuai; Tang, Min; Zhang, Qian; Sun, Zhen; Huang, Fengchen

    2014-01-01

    Underwater moving object detection is the key for many underwater computer vision tasks, such as object recognizing, locating, and tracking. Considering the super ability in visual sensing of the underwater habitats, the visual mechanism of aquatic animals is generally regarded as the cue for establishing bionic models which are more adaptive to the underwater environments. However, the low accuracy rate and the absence of the prior knowledge learning limit their adaptation in underwater applications. Aiming to solve the problems originated from the inhomogeneous lumination and the unstable background, the mechanism of the visual information sensing and processing pattern from the eye of frogs are imitated to produce a hierarchical background model for detecting underwater objects. Firstly, the image is segmented into several subblocks. The intensity information is extracted for establishing background model which could roughly identify the object and the background regions. The texture feature of each pixel in the rough object region is further analyzed to generate the object contour precisely. Experimental results demonstrate that the proposed method gives a better performance. Compared to the traditional Gaussian background model, the completeness of the object detection is 97.92% with only 0.94% of the background region that is included in the detection results.

  7. A Biological Hierarchical Model Based Underwater Moving Object Detection

    PubMed Central

    Shen, Jie; Fan, Tanghuai; Tang, Min; Zhang, Qian; Sun, Zhen; Huang, Fengchen

    2014-01-01

    Underwater moving object detection is the key for many underwater computer vision tasks, such as object recognizing, locating, and tracking. Considering the super ability in visual sensing of the underwater habitats, the visual mechanism of aquatic animals is generally regarded as the cue for establishing bionic models which are more adaptive to the underwater environments. However, the low accuracy rate and the absence of the prior knowledge learning limit their adaptation in underwater applications. Aiming to solve the problems originated from the inhomogeneous lumination and the unstable background, the mechanism of the visual information sensing and processing pattern from the eye of frogs are imitated to produce a hierarchical background model for detecting underwater objects. Firstly, the image is segmented into several subblocks. The intensity information is extracted for establishing background model which could roughly identify the object and the background regions. The texture feature of each pixel in the rough object region is further analyzed to generate the object contour precisely. Experimental results demonstrate that the proposed method gives a better performance. Compared to the traditional Gaussian background model, the completeness of the object detection is 97.92% with only 0.94% of the background region that is included in the detection results. PMID:25140194

  8. Peptide-activated gold nanoparticles for selective visual sensing of virus

    NASA Astrophysics Data System (ADS)

    Sajjanar, Basavaraj; Kakodia, Bhuvna; Bisht, Deepika; Saxena, Shikha; Singh, Arvind Kumar; Joshi, Vinay; Tiwari, Ashok Kumar; Kumar, Satish

    2015-05-01

    In this study, we report peptide-gold nanoparticles (AuNP)-based visual sensor for viruses. Citrate-stabilized AuNP (20 ± 1.9 nm) were functionalized with strong sulfur-gold interface using cysteinylated virus-specific peptide. Peptide-Cys-AuNP formed complexes with the viruses which made them to aggregate. The aggregation can be observed with naked eye and also with UV-Vis spectrophotometer as a color change from bright red to purple. The test allows for fast and selective detection of specific viruses. Spectroscopic measurements showed high linear correlation ( R 2 = 0.995) between the changes in optical density ratio (OD610/OD520) with the different concentrations of virus. The new method was compared with the hemagglutinating (HA) test for Newcastle disease virus (NDV). The results indicated that peptide-Cys-AuNP was more sensitive and can visually detect minimum number of virus particles present in the biological samples. The limit of detection for the NDV was 0.125 HA units of the virus. The method allows for selective detection and quantification of the NDV, and requires no isolation of viral RNA and PCR experiments. This strategy may be utilized for detection of other important human and animal viral pathogens.

  9. Companions in Color: High-Resolution Imaging of Kepler’s Sub-Neptune Host Stars

    NASA Astrophysics Data System (ADS)

    Ware, Austin; Wolfgang, Angie; Kannan, Deepti

    2018-01-01

    A current problem in astronomy is determining how sub-Neptune-sized exoplanets form in planetary systems. These kinds of planets, which fall between 1 and 4 times the size of Earth, were discovered in abundance by the Kepler Mission and were typically found with relatively short orbital periods. The combination of their size and orbital period make them unusual in relation to the Solar System, leading to the question of how these exoplanets form and evolve. One possibility is that they have been influenced by distant stellar companions. To help assess the influence of these objects on the present-day, observed properties of exoplanets, we conduct a NIR search for visual stellar companions to the stars around which the Kepler Mission discovered planets. We use high-resolution images obtained with the adaptive optics systems at the Lick Observatory Shane-3m telescope to find these companion stars. Importantly, we also determine the effective brightness and distance from the planet-hosting star at which it is possible to detect these companions. Out of the 200 KOIs in our sample, 42 KOIs (21%) have visual companions within 3”, and 90 (46%) have them within 6”. These findings are consistent with recent high-resolution imaging from Furlan et al. 2017 that found at least one visual companion within 4” for 31% of sampled KOIs (37% within 4" for our sample). Our results are also complementary to Furlan et al. 2017, with only 17 visual companions commonly detected in the same filter. As for detection limits, our preliminary results indicate that we can detect companion stars < 3-5 magnitudes fainter than the planet-hosting star at a separation of ~ 1”. These detection limits will enable us to determine the probability that possible companion stars could be hidden within the noise around the planet-hosting star, an important step in determining the frequency with which these short-period, sub-Neptune-sized planets occur within binary star systems.

  10. Exploring the Thermal Limits of IR-Based Automatic Whale Detection

    DTIC Science & Technology

    2014-09-30

    spouts during the northward humpback whale migration, which occurs annually rather close to shore near North Stradbroke Island, Queensland, Australia...with concurrent visual observations. APPROACH By obtaining continuous IR video footage during two successive northward humpback whale ... Whale Detection (ETAW) Olaf Boebel P.O. Box 120161 27515 Bremerhaven GERMANY phone: +49 (471) 4831-1879 fax: +49 (471) 4831-1797 email

  11. Establishment and application of a novel isothermal amplification assay for rapid detection of chloroquine resistance (K76T) in Plasmodium falciparum

    PubMed Central

    Chahar, Madhvi; Mishra, Neelima; Anvikar, Anup; Dixit, Rajnikant; Valecha, Neena

    2017-01-01

    Chloroquine (CQ) resistance in Plasmodium falciparum is determined by the mutations in the chloroquine resistance transporter (Pfcrt) gene. The point mutation at codon 76 (K76T), which has been observed in more than 91% of P. falciparum isolates in India, is the major determinant of CQ resistance. To overcome the limitations and challenges of traditional methods, in this investigation we developed an easy to use loop mediated isothermal amplification (LAMP) protocol for rapid detection of the K76T mutation associated with CQ resistance in P. falciparum with naked eye visualization. In- house designed primers were synthesized and optimized to specifically distinguish the CQ resistant mutants of P. falciparum. The LAMP reaction was optimal at 61 °C for 60 min and calcein dye was added prior to amplification to enable visual detection. We demonstrate the detection limit of <2 ng/μl respectively, supporting the high sensitivity of this calcein based LAMP method. To the best of our knowledge this is the first report on the establishment of an easy, reliable and cost effective LAMP assay for rapid and specific detection of highly CQ resistance in P. falciparum malaria. PMID:28134241

  12. "Reactive" optical sensor for Hg2+ and its application in environmental aqueous media and biological systems.

    PubMed

    Chen, Zhi; Chen, Jiayun; Pan, Dong; Li, Hongwei; Yao, Yunhui; Lyu, Zu; Yang, Liting; Ma, Li-Jun

    2017-03-01

    A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. Sensor 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity (detection limits are 27.6 nM (5.5 ppb) and 6.9 nM (1.4 ppb), respectively) in neutral buffer solution. To test its applicability in the environment, sensor 1 was applied to quantify and visualize low levels of Hg 2+ in tap water and river water samples. The results indicate sensor 1 is a highly sensitive fluorescent sensor for Hg 2+ with a detection limit of 1.7 ppb in tap water and river water. Moreover, sensor 1 is a convenient visualizing sensor for low levels of Hg 2+ (0.1 ppm) in water environment (from colorless to light pink). In addition, sensor 1 shows good potential as a fluorescent visualizing sensor for Hg 2+ in fetal bovine serum and living 293T cells. The results indicate that sensor 1 shows good potential as a highly sensitive sensor for the detection of Hg 2+ in environmental and biological samples. Graphical Abstract A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity in water environment. And it is a convenient visualizing probe for low levels of Hg 2+ in environment aqueous media, fetal bovine serum and living 293T cells.

  13. A Reaction-Based Novel Fluorescent Probe for Detection of Hydrogen Sulfide and Its Application in Wine.

    PubMed

    Wang, Hao; Wang, Jialin; Yang, Shaoxiang; Tian, Hongyu; Sun, Baoguo; Liu, Yongguo

    2018-01-01

    A new reaction-based fluorescent probe 6-cyanonaphthalen-2-yl-2,4- dinitrobenzenesulfonate (probe 1) was designed and synthesized for detection of hydrogen sulfide (H 2 S). The addition of H 2 S to a solution of probe 1 resulted in a marked fluorescence increased accompanied by a visual color change from colorless to yellow. Importantly, this distinct color response indicates that probe 1 could be used as a visual tool for detection of H 2 S. H 2 S can be detected quantitatively in the concentration range 0 to 25 μM and the detection limit was 30 nM. Moreover, probe 1 was successfully used as a sensor to determine H 2 S levels in red wine and beer. Fluorescent probe 1 could be employed as a visible sensor for H 2 S. Probe 1 could be used to detect H 2 S quantitatively in food simple. © 2017 Institute of Food Technologists®.

  14. Information theoretic analysis of canny edge detection in visual communication

    NASA Astrophysics Data System (ADS)

    Jiang, Bo; Rahman, Zia-ur

    2011-06-01

    In general edge detection evaluation, the edge detectors are examined, analyzed, and compared either visually or with a metric for specific an application. This analysis is usually independent of the characteristics of the image-gathering, transmission and display processes that do impact the quality of the acquired image and thus, the resulting edge image. We propose a new information theoretic analysis of edge detection that unites the different components of the visual communication channel and assesses edge detection algorithms in an integrated manner based on Shannon's information theory. The edge detection algorithm here is considered to achieve high performance only if the information rate from the scene to the edge approaches the maximum possible. Thus, by setting initial conditions of the visual communication system as constant, different edge detection algorithms could be evaluated. This analysis is normally limited to linear shift-invariant filters so in order to examine the Canny edge operator in our proposed system, we need to estimate its "power spectral density" (PSD). Since the Canny operator is non-linear and shift variant, we perform the estimation for a set of different system environment conditions using simulations. In our paper we will first introduce the PSD of the Canny operator for a range of system parameters. Then, using the estimated PSD, we will assess the Canny operator using information theoretic analysis. The information-theoretic metric is also used to compare the performance of the Canny operator with other edge-detection operators. This also provides a simple tool for selecting appropriate edgedetection algorithms based on system parameters, and for adjusting their parameters to maximize information throughput.

  15. The Objective Identification and Quantification of Interstitial Lung Abnormalities in Smokers.

    PubMed

    Ash, Samuel Y; Harmouche, Rola; Ross, James C; Diaz, Alejandro A; Hunninghake, Gary M; Putman, Rachel K; Onieva, Jorge; Martinez, Fernando J; Choi, Augustine M; Lynch, David A; Hatabu, Hiroto; Rosas, Ivan O; Estepar, Raul San Jose; Washko, George R

    2017-08-01

    Previous investigation suggests that visually detected interstitial changes in the lung parenchyma of smokers are highly clinically relevant and predict outcomes, including death. Visual subjective analysis to detect these changes is time-consuming, insensitive to subtle changes, and requires training to enhance reproducibility. Objective detection of such changes could provide a method of disease identification without these limitations. The goal of this study was to develop and test a fully automated image processing tool to objectively identify radiographic features associated with interstitial abnormalities in the computed tomography scans of a large cohort of smokers. An automated tool that uses local histogram analysis combined with distance from the pleural surface was used to detect radiographic features consistent with interstitial lung abnormalities in computed tomography scans from 2257 individuals from the Genetic Epidemiology of COPD study, a longitudinal observational study of smokers. The sensitivity and specificity of this tool was determined based on its ability to detect the visually identified presence of these abnormalities. The tool had a sensitivity of 87.8% and a specificity of 57.5% for the detection of interstitial lung abnormalities, with a c-statistic of 0.82, and was 100% sensitive and 56.7% specific for the detection of the visual subtype of interstitial abnormalities called fibrotic parenchymal abnormalities, with a c-statistic of 0.89. In smokers, a fully automated image processing tool is able to identify those individuals who have interstitial lung abnormalities with moderate sensitivity and specificity. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Visual colorimetric detection of tin(II) and nitrite using a molybdenum oxide nanomaterial-based three-input logic gate.

    PubMed

    Du, Jiayan; Zhao, Mengxin; Huang, Wei; Deng, Yuequan; He, Yi

    2018-05-09

    We report a molybdenum oxide (MoO 3 ) nanomaterial-based three-input logic gate that uses Sn 2+ , NO 2 - , and H + ions as inputs. Under acidic conditions, Sn 2+ is able to reduce MoO 3 nanosheets, generating oxygen-vacancy-rich MoO 3-x nanomaterials along with strong localized surface plasmon resonance (LSPR) and an intense blue solution as the output signal. When NO 2 - is introduced, the redox reaction between the MoO 3 nanosheets and Sn 2+ is strongly inhibited because the NO 2 - consumes both H + and Sn 2+ . The three-input logic gate was employed for the visual colorimetric detection of Sn 2+ and NO 2 - under different input states. The colorimetric assay's limit of detection for Sn 2+ and the lowest concentration of NO 2 - detectable by the assay were found to be 27.5 nM and 0.1 μM, respectively. The assay permits the visual detection of Sn 2+ and NO 2 - down to concentrations as low as 2 μM and 25 μM, respectively. The applicability of the logic-gate-based colorimetric assay was demonstrated by using it to detect Sn 2+ and NO 2 - in several water sources.

  17. Multispectral photoacoustic tomography for detection of small tumors inside biological tissues

    NASA Astrophysics Data System (ADS)

    Hirasawa, Takeshi; Okawa, Shinpei; Tsujita, Kazuhiro; Kushibiki, Toshihiro; Fujita, Masanori; Urano, Yasuteru; Ishihara, Miya

    2018-02-01

    Visualization of small tumors inside biological tissue is important in cancer treatment because that promotes accurate surgical resection and enables therapeutic effect monitoring. For sensitive detection of tumor, we have been developing photoacoustic (PA) imaging technique to visualize tumor-specific contrast agents, and have already succeeded to image a subcutaneous tumor of a mouse using the contrast agents. To image tumors inside biological tissues, extension of imaging depth and improvement of sensitivity were required. In this study, to extend imaging depth, we developed a PA tomography (PAT) system that can image entire cross section of mice. To improve sensitivity, we discussed the use of the P(VDF-TrFE) linear array acoustic sensor that can detect PA signals with wide ranges of frequencies. Because PA signals produced from low absorbance optical absorbers shifts to low frequency, we hypothesized that the detection of low frequency PA signals improves sensitivity to low absorbance optical absorbers. We developed a PAT system with both a PZT linear array acoustic sensor and the P(VDF-TrFE) sensor, and performed experiment using tissue-mimicking phantoms to evaluate lower detection limits of absorbance. As a result, PAT images calculated from low frequency components of PA signals detected by the P(VDF-TrFE) sensor could visualize optical absorbers with lower absorbance.

  18. A signal detection model predicts the effects of set size on visual search accuracy for feature, conjunction, triple conjunction, and disjunction displays

    NASA Technical Reports Server (NTRS)

    Eckstein, M. P.; Thomas, J. P.; Palmer, J.; Shimozaki, S. S.

    2000-01-01

    Recently, quantitative models based on signal detection theory have been successfully applied to the prediction of human accuracy in visual search for a target that differs from distractors along a single attribute (feature search). The present paper extends these models for visual search accuracy to multidimensional search displays in which the target differs from the distractors along more than one feature dimension (conjunction, disjunction, and triple conjunction displays). The model assumes that each element in the display elicits a noisy representation for each of the relevant feature dimensions. The observer combines the representations across feature dimensions to obtain a single decision variable, and the stimulus with the maximum value determines the response. The model accurately predicts human experimental data on visual search accuracy in conjunctions and disjunctions of contrast and orientation. The model accounts for performance degradation without resorting to a limited-capacity spatially localized and temporally serial mechanism by which to bind information across feature dimensions.

  19. Visual format for detection of Mycobacterium tuberculosis and M. bovis in clinical samples using molecular beacons.

    PubMed

    Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K; Vishalakshi, Potharuju; Chauhan, Devender S; Katoch, Vishwa M; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K

    2009-09-01

    A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete.

  20. Visual Format for Detection of Mycobacterium tuberculosis and M. bovis in Clinical Samples Using Molecular Beacons

    PubMed Central

    Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K.; Vishalakshi, Potharuju; Chauhan, Devender S.; Katoch, Vishwa M.; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K.

    2009-01-01

    A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete. PMID:19661384

  1. Progressive data transmission for anatomical landmark detection in a cloud.

    PubMed

    Sofka, M; Ralovich, K; Zhang, J; Zhou, S K; Comaniciu, D

    2012-01-01

    In the concept of cloud-computing-based systems, various authorized users have secure access to patient records from a number of care delivery organizations from any location. This creates a growing need for remote visualization, advanced image processing, state-of-the-art image analysis, and computer aided diagnosis. This paper proposes a system of algorithms for automatic detection of anatomical landmarks in 3D volumes in the cloud computing environment. The system addresses the inherent problem of limited bandwidth between a (thin) client, data center, and data analysis server. The problem of limited bandwidth is solved by a hierarchical sequential detection algorithm that obtains data by progressively transmitting only image regions required for processing. The client sends a request to detect a set of landmarks for region visualization or further analysis. The algorithm running on the data analysis server obtains a coarse level image from the data center and generates landmark location candidates. The candidates are then used to obtain image neighborhood regions at a finer resolution level for further detection. This way, the landmark locations are hierarchically and sequentially detected and refined. Only image regions surrounding landmark location candidates need to be trans- mitted during detection. Furthermore, the image regions are lossy compressed with JPEG 2000. Together, these properties amount to at least 30 times bandwidth reduction while achieving similar accuracy when compared to an algorithm using the original data. The hierarchical sequential algorithm with progressive data transmission considerably reduces bandwidth requirements in cloud-based detection systems.

  2. Detection Limits for Spectro-fluorometry: A Case Study in the Region of Finstersee, Canton Zug, Northern Switzerland

    NASA Astrophysics Data System (ADS)

    Otz, M. H.; Otz, H. K.; Keller, P.

    2002-05-01

    Synthetic fluorescent dyes, applied below the visual detection limit (< 0.1 mg/L), have been used as tracers of ground water flow paths since the beginning of the 1950s. Since 1965, we have used spectro-fluorometers with photomultipliers to measure low concentrations of fluorescent dyes in ground water in Switzerland. In collaboration with the Engineering Geology Department of the ETH, we have separated uranine at 0.1 ng/L and Na-naphtionate at 1 ng/L from background fluorescence of spring water in the Finstersee region. These values are 10-100 times lower than postulated detection limits in the literature. The use of low dye concentrations prevents a study region from being contaminated by increased background levels due to remnant dye within the aquifer, thereby leaving the region available for future dye tracing studies. Lower detection limits also can solve particular hydraulic problems where conventional methods fail and enhance the possibility for using artificial dyes in environmentally sensitive aquifer settings.

  3. A novel reaction-based fluorescent probe for the detection of cysteine in milk and water samples.

    PubMed

    Wang, Jialin; Wang, Hao; Hao, Yanfeng; Yang, Shaoxiang; Tian, Hongyu; Sun, Baoguo; Liu, Yongguo

    2018-10-01

    A novel fluorescent probe 3'-hydroxy-3-oxo-3H-spiro [isobenzofuran-1,9'-xanthene]-6'-yl-2,4-dinitrobenzenesulfonate (probe 1) was designed and synthesized as a visual sensor for the detection of cysteine levels in milk and water samples. The addition of cysteine to the solution of probe 1 resulted in an increase in fluorescence intensity and color change, from light yellow to yellow-green. The distinct color response indicated that probe 1 could be used as a visual sensor for cysteine. Cysteine can be detected quantitatively at concentrations between 0 and 400 μM and the detection limit of the fluorescence response to the probe was 6.5 μM. This suggests that probe 1 could be used as a signaling tool to determine the cysteine levels in samples, such as milk and water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Skin self-examinations and visual identification of atypical nevi: comparing individual and crowdsourcing approaches.

    PubMed

    King, Andy J; Gehl, Robert W; Grossman, Douglas; Jensen, Jakob D

    2013-12-01

    Skin self-examination (SSE) is one method for identifying atypical nevi among members of the general public. Unfortunately, past research has shown that SSE has low sensitivity in detecting atypical nevi. The current study investigates whether crowdsourcing (collective effort) can improve SSE identification accuracy. Collective effort is potentially useful for improving people's visual identification of atypical nevi during SSE because, even when a single person has low reliability at a task, the pattern of the group can overcome the limitations of each individual. Adults (N=500) were recruited from a shopping mall in the Midwest. Participants viewed educational pamphlets about SSE and then completed a mole identification task. For the task, participants were asked to circle mole images that appeared atypical. Forty nevi images were provided; nine of the images were of nevi that were later diagnosed as melanoma. Consistent with past research, individual effort exhibited modest sensitivity (.58) for identifying atypical nevi in the mole identification task. As predicted, collective effort overcame the limitations of individual effort. Specifically, a 19% collective effort identification threshold exhibited superior sensitivity (.90). The results of the current study suggest that limitations of SSE can be countered by collective effort, a finding that supports the pursuit of interventions promoting early melanoma detection that contain crowdsourced visual identification components. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Exploring the Thermal Limits of IR-Based Automatic Whale Detection (ETAW)

    DTIC Science & Technology

    2013-09-30

    the northward humpback whale migration, which occurs annually rather close to shore near North Stradbroke Island, Queensland, Australia. Based on the...successive northward humpback whale migrations and collecting concurrent independent (double blind) visual observations (modified cue counting), a... Whale Detection (ETAW) Olaf Boebel P.O. Box 120161 27515 Bremerhaven Germany phone: +49 (471) 4831-1879 fax: +49 (471) 4831-1797 email

  6. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    PubMed

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis. Furthermore, this approach demonstrated higher interobserver and intraobserver reliability as well as a better time efficiency when compared to visual analysis.

  7. Detection of periodontal pathogen Porphyromonas gingivalis by loop-mediated isothermal amplification method.

    PubMed

    Maeda, Hiroshi; Kokeguchi, Susumu; Fujimoto, Chiyo; Tanimoto, Ichiro; Yoshizumi, Wakako; Nishimura, Fusanori; Takashiba, Shogo

    2005-02-01

    A method for nucleic acid amplification, loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for periodontal pathogen, Porphyromonas gingivalis. A set of six primers was designed by targeting the 16S ribosomal RNA gene. By the detection system, target DNA was amplified and visualized on agarose gel within 30 min under isothermal condition at 64 degrees C with a detection limit of 20 cells of P. gingivalis. Without gel electrophoresis, the LAMP amplicon was directly visualized in the reaction tube by addition of SYBR Green I for a naked-eye inspection. The LAMP reaction was also assessed by white turbidity of magnesium pyrophosphate (a by-product of LAMP) in the tube. Detection limits of these naked-eye inspections were 20 cells and 200 cells, respectively. Although false-positive DNA amplification was observed from more than 10(7) cells of Porphyromonas endodontalis, no amplification was observed in other five related oral pathogens. Further, quantitative detection of P. gingivalis was accomplished by a real-time monitoring of the LAMP reaction using SYBR Green I with linearity over a range of 10(2)-10(6) cells. The real-time LAMP was then applied to clinical samples of dental plaque and demonstrated almost identical results to the conventional real-time PCR with an advantage of rapidity. These findings indicate the potential usefulness of LAMP for detecting and quantifying P. gingivalis, especially in its rapidity and simplicity.

  8. Design and synthesis of target-responsive aptamer-cross-linked hydrogel for visual quantitative detection of ochratoxin A.

    PubMed

    Liu, Rudi; Huang, Yishun; Ma, Yanli; Jia, Shasha; Gao, Mingxuan; Li, Jiuxing; Zhang, Huimin; Xu, Dunming; Wu, Min; Chen, Yan; Zhu, Zhi; Yang, Chaoyong

    2015-04-01

    A target-responsive aptamer-cross-linked hydrogel was designed and synthesized for portable and visual quantitative detection of the toxin Ochratoxin A (OTA), which occurs in food and beverages. The hydrogel network forms by hybridization between one designed DNA strand containing the OTA aptamer and two complementary DNA strands grafting on linear polyacrylamide chains. Upon the introduction of OTA, the aptamer binds with OTA, leading to the dissociation of the hydrogel, followed by release of the preloaded gold nanoparticles (AuNPs), which can be observed by the naked eye. To enable sensitive visual and quantitative detection, we encapsulated Au@Pt core-shell nanoparticles (Au@PtNPs) in the hydrogel to generate quantitative readout in a volumetric bar-chart chip (V-Chip). In the V-Chip, Au@PtNPs catalyzes the oxidation of H2O2 to generate O2, which induces movement of an ink bar to a concentration-dependent distance for visual quantitative readout. Furthermore, to improve the detection limit in complex real samples, we introduced an immunoaffinity column (IAC) of OTA to enrich OTA from beer. After the enrichment, as low as 1.27 nM (0.51 ppb) OTA can be detected by the V-Chip, which satisfies the test requirement (2.0 ppb) by the European Commission. The integration of a target-responsive hydrogel with portable enrichment by IAC, as well as signal amplification and quantitative readout by a simple microfluidic device, offers a new method for portable detection of food safety hazard toxin OTA.

  9. Comparison of hoop-net trapping and visual surveys to monitor abundance of the Rio Grande cooter (Pseudemys gorzugi).

    PubMed

    Mali, Ivana; Duarte, Adam; Forstner, Michael R J

    2018-01-01

    Abundance estimates play an important part in the regulatory and conservation decision-making process. It is important to correct monitoring data for imperfect detection when using these data to track spatial and temporal variation in abundance, especially in the case of rare and elusive species. This paper presents the first attempt to estimate abundance of the Rio Grande cooter ( Pseudemys gorzugi ) while explicitly considering the detection process. Specifically, in 2016 we monitored this rare species at two sites along the Black River, New Mexico via traditional baited hoop-net traps and less invasive visual surveys to evaluate the efficacy of these two sampling designs. We fitted the Huggins closed-capture estimator to estimate capture probabilities using the trap data and distance sampling models to estimate detection probabilities using the visual survey data. We found that only the visual survey with the highest number of observed turtles resulted in similar abundance estimates to those estimated using the trap data. However, the estimates of abundance from the remaining visual survey data were highly variable and often underestimated abundance relative to the estimates from the trap data. We suspect this pattern is related to changes in the basking behavior of the species and, thus, the availability of turtles to be detected even though all visual surveys were conducted when environmental conditions were similar. Regardless, we found that riverine habitat conditions limited our ability to properly conduct visual surveys at one site. Collectively, this suggests visual surveys may not be an effective sample design for this species in this river system. When analyzing the trap data, we found capture probabilities to be highly variable across sites and between age classes and that recapture probabilities were much lower than initial capture probabilities, highlighting the importance of accounting for detectability when monitoring this species. Although baited hoop-net traps seem to be an effective sampling design, it is important to note that this method required a relatively high trap effort to reliably estimate abundance. This information will be useful when developing a larger-scale, long-term monitoring program for this species of concern.

  10. Vision and foraging in cormorants: more like herons than hawks?

    PubMed

    White, Craig R; Day, Norman; Butler, Patrick J; Martin, Graham R

    2007-07-25

    Great cormorants (Phalacrocorax carbo L.) show the highest known foraging yield for a marine predator and they are often perceived to be in conflict with human economic interests. They are generally regarded as visually-guided, pursuit-dive foragers, so it would be expected that cormorants have excellent vision much like aerial predators, such as hawks which detect and pursue prey from a distance. Indeed cormorant eyes appear to show some specific adaptations to the amphibious life style. They are reported to have a highly pliable lens and powerful intraocular muscles which are thought to accommodate for the loss of corneal refractive power that accompanies immersion and ensures a well focussed image on the retina. However, nothing is known of the visual performance of these birds and how this might influence their prey capture technique. We measured the aquatic visual acuity of great cormorants under a range of viewing conditions (illuminance, target contrast, viewing distance) and found it to be unexpectedly poor. Cormorant visual acuity under a range of viewing conditions is in fact comparable to unaided humans under water, and very inferior to that of aerial predators. We present a prey detectability model based upon the known acuity of cormorants at different illuminances, target contrasts and viewing distances. This shows that cormorants are able to detect individual prey only at close range (less than 1 m). We conclude that cormorants are not the aquatic equivalent of hawks. Their efficient hunting involves the use of specialised foraging techniques which employ brief short-distance pursuit and/or rapid neck extension to capture prey that is visually detected or flushed only at short range. This technique appears to be driven proximately by the cormorant's limited visual capacities, and is analogous to the foraging techniques employed by herons.

  11. Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification.

    PubMed

    Chen, Xiaoyun; Wang, Xiaofu; Jin, Nuo; Zhou, Yu; Huang, Sainan; Miao, Qingmei; Zhu, Qing; Xu, Junfeng

    2012-11-07

    Genetically modified (GM) rice KMD1, TT51-1, and KF6 are three of the most well known transgenic Bt rice lines in China. A rapid and sensitive molecular assay for risk assessment of GM rice is needed. Polymerase chain reaction (PCR), currently the most common method for detecting genetically modified organisms, requires temperature cycling and relatively complex procedures. Here we developed a visual and rapid loop-mediated isothermal amplification (LAMP) method to amplify three GM rice event-specific junction sequences. Target DNA was amplified and visualized by two indicators (SYBR green or hydroxy naphthol blue [HNB]) within 60 min at an isothermal temperature of 63 °C. Different kinds of plants were selected to ensure the specificity of detection and the results of the non-target samples were negative, indicating that the primer sets for the three GM rice varieties had good levels of specificity. The sensitivity of LAMP, with detection limits at low concentration levels (0.01%−0.005% GM), was 10- to 100-fold greater than that of conventional PCR. Additionally, the LAMP assay coupled with an indicator (SYBR green or HNB) facilitated analysis. These findings revealed that the rapid detection method was suitable as a simple field-based test to determine the status of GM crops.

  12. Polymer Vesicle Sensor for Visual and Sensitive Detection of SO2 in Water.

    PubMed

    Huang, Tong; Hou, Zhilin; Xu, Qingsong; Huang, Lei; Li, Chuanlong; Zhou, Yongfeng

    2017-01-10

    This study reports the first polymer vesicle sensor for the visual detection of SO 2 and its derivatives in water. A strong binding ability between tertiary alkanolamines and SO 2 has been used as the driving force for the detection by the graft of tertiary amine alcohol (TAA) groups onto an amphiphilic hyperbranched multiarm polymer, which can self-assemble into vesicles with enriched TAA groups on the surface. The polymer vesicles will undergo proton exchange with cresol red (CR) to produce CR-immobilized vesicles (CR@vesicles). Subsequently, through competitive binding with the TAA groups between CR and SO 2 or HSO 3 - , the CR@vesicles (purple) can quickly change into SO 2 @vesicles (colorless) with the release of protonated CR (yellow). Such a fast purple to yellow transition in the solution allows the visual detection of SO 2 or its derivatives in water by the naked eye. A visual test paper for SO 2 gas has also been demonstrated by the adsorption of CR@vesicles onto paper. Meanwhile, the detection limit of CR@vesicles for HSO 3 - is approximately 25 nM, which is improved by approximately 30 times when compared with that of small molecule-based sensors with a similar structure (0.83 μM). Such an enhanced detection sensitivity should be related to the enrichment of TAA groups as well as the CR in CR@vesicles. In addition, the CR@vesicle sensors also show selectivity and specificity for the detection of SO 2 or HSO 3 - among anions such as F - , Br - , Cl - , SO 4 2- , NO 2 - , C 2 O 4 2- , S 2 O 3 2- , SCN - , AcO - , SO 3 2- , S 2- , and HCO 3 - .

  13. Detection of flow limitation in obstructive sleep apnea with an artificial neural network.

    PubMed

    Norman, Robert G; Rapoport, David M; Ayappa, Indu

    2007-09-01

    During sleep, the development of a plateau on the inspiratory airflow/time contour provides a non-invasive indicator of airway collapsibility. Humans recognize this abnormal contour easily, and this study replicates this with an artificial neural network (ANN) using a normalized shape. Five 10 min segments were selected from each of 18 sleep records (respiratory airflow measured with a nasal cannula) with varying degrees of sleep disordered breathing. Each breath was visually scored for shape, and breaths split randomly into a training and test set. Equally spaced, peak amplitude normalized flow values (representing breath shape) formed the only input to a back propagation ANN. Following training, breath-by-breath agreement of the ANN with the manual classification was tabulated for the training and test sets separately. Agreement of the ANN was 89% in the training set and 70.6% in the test set. When the categories of 'probably normal' and 'normal', and 'probably flow limited' and 'flow limited' were combined, the agreement increased to 92.7% and 89.4% respectively, similar to the intra- and inter-rater agreements obtained by a visual classification of these breaths. On a naive dataset, the agreement of the ANN to visual classification was 57.7% overall and 82.4% when the categories were collapsed. A neural network based only on the shape of inspiratory airflow succeeded in classifying breaths as to the presence/absence of flow limitation. This approach could be used to provide a standardized, reproducible and automated means of detecting elevated upper airway resistance.

  14. The uncrowded window of object recognition

    PubMed Central

    Pelli, Denis G; Tillman, Katharine A

    2009-01-01

    It is now emerging that vision is usually limited by object spacing rather than size. The visual system recognizes an object by detecting and then combining its features. ‘Crowding’ occurs when objects are too close together and features from several objects are combined into a jumbled percept. Here, we review the explosion of studies on crowding—in grating discrimination, letter and face recognition, visual search, selective attention, and reading—and find a universal principle, the Bouma law. The critical spacing required to prevent crowding is equal for all objects, although the effect is weaker between dissimilar objects. Furthermore, critical spacing at the cortex is independent of object position, and critical spacing at the visual field is proportional to object distance from fixation. The region where object spacing exceeds critical spacing is the ‘uncrowded window’. Observers cannot recognize objects outside of this window and its size limits the speed of reading and search. PMID:18828191

  15. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care

    PubMed Central

    2014-01-01

    Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care. PMID:24593868

  16. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care.

    PubMed

    Watanabe, Reina; Shimoda, Tomoko; Yano, Rika; Hayashi, Yasuhiro; Nakamura, Shinji; Matsuo, Junji; Yamaguchi, Hiroyuki

    2014-03-04

    Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.

  17. Towards Understanding the Role of Colour Information in Scene Perception using Night Vision Device

    DTIC Science & Technology

    2009-06-01

    possessing a visual system much simplified from that of living birds, reptiles, and teleost (bony) fish , which are generally tetrachromatic (Bowmaker...Levkowitz and Herman (1992) speculated that the results might be limited to “ blob ” detection. A possible mediating factor may have been the size and...sharpness of the “ blobs ” used in their task. Mullen (1985) showed that the visual system is much more sensitive to the 7 DSTO-RR-0345 high spatial

  18. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    PubMed

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  19. Visual perception and social foraging in birds.

    PubMed

    Fernández-Juricic, Esteban; Erichsen, Jonathan T; Kacelnik, Alex

    2004-01-01

    Birds gather information about their environment mainly through vision by scanning their surroundings. Many prevalent models of social foraging assume that foraging and scanning are mutually exclusive. Although this assumption is valid for birds with narrow visual fields, these models have also been applied to species with wide fields. In fact, available models do not make precise predictions for birds with large visual fields, in which the head-up, head-down dichotomy is not accurate and, moreover, do not consider the effects of detection distance and limited attention. Studies of how different types of visual information are acquired as a function of body posture and of how information flows within flocks offer new insights into the costs and benefits of living in groups.

  20. Development of a rapid and visual nucleotide detection method for a Chinese epidemic strain of Orientia tsutsugamushi based on recombinase polymerase amplification assay and lateral flow test.

    PubMed

    Qi, Yong; Yin, Qiong; Shao, Yinxiu; Cao, Min; Li, Suqin; Chen, Hongxia; Shen, Wanpeng; Rao, Jixian; Li, Jiameng; Li, Xiaoling; Sun, Yu; Lin, Yu; Deng, Yi; Zeng, Wenwen; Zheng, Shulong; Liu, Suyun; Li, Yuexi

    2018-05-01

    Orientia tsutsugamushi is an obligate intracellular pathogen that causes scrub typhus. Diagnosing scrub typhus remains a challenge, and a sensitive, specific, simple, and rapid diagnostic test is still needed. A recombinase polymerase amplification (RPA) assay combined with a lateral flow (LF) test targeting the 56-kDa gene of a Karp-like strain of O. tsutsugamushi was developed and optimized. The detection limits, sensitivity, specificity, and simulative clinical performance were evaluated. Primers and probe were screened to establish the RPA assay, and the reaction conditions were optimized. The detection limit was 10 copies/reaction in detecting plasmid DNA and 12 copies/reaction in detecting genomic DNA. The RPA-LF method could differentiate O. tsutsugamushi from other phylogenetically related bacteria. The sensitivity was 100% and specificity was over 90%, when evaluated using infected animal samples or simulative clinical samples. Furthermore, the method was completed in 20min at 37°C followed by a 3-5min incubation at room temperature for the development of an immunochromatographic strip, and the results could be determined visually. This method is promising for wide-ranging use in basic medical units considering that it requires minimal instruments and infrastructure and is highly time-efficient, sensitive, and specific for diagnosing scrub typhus. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Visual cues for woodpeckers: light reflectance of decayed wood varies by decay fungus

    USGS Publications Warehouse

    O'Daniels, Sean T.; Kesler, Dylan C.; Mihail, Jeanne D.; Webb, Elisabeth B.; Werner, Scott J.

    2018-01-01

    The appearance of wood substrates is likely relevant to bird species with life histories that require regular interactions with wood for food and shelter. Woodpeckers detect decayed wood for cavity placement or foraging, and some species may be capable of detecting trees decayed by specific fungi; however, a mechanism allowing for such specificity remains unidentified. We hypothesized that decay fungi associated with woodpecker cavity sites alter the substrate reflectance in a species-specific manner that is visually discriminable by woodpeckers. We grew 10 species of wood decay fungi from pure cultures on sterile wood substrates of 3 tree species. We then measured the relative reflectance spectra of decayed and control wood wafers and compared them using the receptor noise-limited (RNL) color discrimination model. The RNL model has been used in studies of feather coloration, egg shells, flowers, and fruit to model how the colors of objects appear to birds. Our analyses indicated 6 of 10 decayed substrate/control comparisons were above the threshold of discrimination (i.e., indicating differences discriminable by avian viewers), and 12 of 13 decayed substrate comparisons were also above threshold for a hypothetical woodpecker. We conclude that woodpeckers should be capable of visually detecting decayed wood on trees where bark is absent, and they should also be able to detect visually species-specific differences in wood substrates decayed by fungi used in this study. Our results provide evidence for a visual mechanism by which woodpeckers could identify and select substrates decayed by specific fungi, which has implications for understanding ecologically important woodpecker–fungus interactions.

  2. Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques

    NASA Astrophysics Data System (ADS)

    Vavrik, D.; Jakubek, J.; Jandejsek, I.; Krejci, F.; Kumpova, I.; Zemlicka, J.

    2015-04-01

    This work is focused on the development of instrumental radiographic methods for detection of delaminations in layered carbon fibre reinforced plastic composites used in the aerospace industry. The main limitation of current visualisation techniques is a very limited possibility to image so-called closed delaminations in which delaminated layers are in contact practically with no physical gap. In this contribution we report the development of innovative methods for closed delamination detection using an X-ray phase contrast technique for which the distance between delamination surfaces is not relevant. The approach is based on the energetic sensitivity of phase-enhanced radiography. Based on the applied methodology, we can distinguish both closed and open delamination. Further we have demonstrated the possibility to visualise open delaminations characterised by a physical gap between delaminated layers. This delamination type was successfully identified and visualized utilizing a high resolution and computed tomography table-top technique based on proper beam-hardening effect correction.

  3. Visual performance on detection tasks with double-targets of the same and different difficulty.

    PubMed

    Chan, Alan H S; Courtney, Alan J; Ma, C W

    2002-10-20

    This paper reports a study of measurement of horizontal visual sensitivity limits for 16 subjects in single-target and double-targets detection tasks. Two phases of tests were conducted in the double-targets task; targets of the same difficulty were tested in phase one while targets of different difficulty were tested in phase two. The range of sensitivity for the double-targets test was found to be smaller than that for single-target in both the same and different target difficulty cases. The presence of another target was found to affect performance to a marked degree. Interference effect of the difficult target on detection of the easy one was greater than that of the easy one on the detection of the difficult one. Performance decrement was noted when correct percentage detection was plotted against eccentricity of target in both the single-target and double-targets tests. Nevertheless, the non-significant correlation found between the performance for the two tasks demonstrated that it was impossible to predict quantitatively ability for detection of double targets from the data for single targets. This indicated probable problems in generalizing data for single target visual lobes to those for multiple targets. Also lobe area values obtained from measurements using a single-target task cannot be applied in a mathematical model for situations with multiple occurrences of targets.

  4. Visual saliency detection based on in-depth analysis of sparse representation

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Shen, Siqiu; Ning, Chen

    2018-03-01

    Visual saliency detection has been receiving great attention in recent years since it can facilitate a wide range of applications in computer vision. A variety of saliency models have been proposed based on different assumptions within which saliency detection via sparse representation is one of the newly arisen approaches. However, most existing sparse representation-based saliency detection methods utilize partial characteristics of sparse representation, lacking of in-depth analysis. Thus, they may have limited detection performance. Motivated by this, this paper proposes an algorithm for detecting visual saliency based on in-depth analysis of sparse representation. A number of discriminative dictionaries are first learned with randomly sampled image patches by means of inner product-based dictionary atom classification. Then, the input image is partitioned into many image patches, and these patches are classified into salient and nonsalient ones based on the in-depth analysis of sparse coding coefficients. Afterward, sparse reconstruction errors are calculated for the salient and nonsalient patch sets. By investigating the sparse reconstruction errors, the most salient atoms, which tend to be from the most salient region, are screened out and taken away from the discriminative dictionaries. Finally, an effective method is exploited for saliency map generation with the reduced dictionaries. Comprehensive evaluations on publicly available datasets and comparisons with some state-of-the-art approaches demonstrate the effectiveness of the proposed algorithm.

  5. Propagation and perception of bioluminescence: factors affecting counterillumination as a cryptic strategy.

    PubMed

    Johnsen, Sönke; Widder, Edith A; Mobley, Curtis D

    2004-08-01

    Many deep-sea species, particularly crustaceans, cephalopods, and fish, use photophores to illuminate their ventral surfaces and thus disguise their silhouettes from predators viewing them from below. This strategy has several potential limitations, two of which are examined here. First, a predator with acute vision may be able to detect the individual photophores on the ventral surface. Second, a predator may be able to detect any mismatch between the spectrum of the bioluminescence and that of the background light. The first limitation was examined by modeling the perceived images of the counterillumination of the squid Abralia veranyi and the myctophid fish Ceratoscopelus maderensis as a function of the distance and visual acuity of the viewer. The second limitation was addressed by measuring downwelling irradiance under moonlight and starlight and then modeling underwater spectra. Four water types were examined: coastal water at a depth of 5 m and oceanic water at 5, 210, and 800 m. The appearance of the counterillumination was more affected by the visual acuity of the viewer than by the clarity of the water, even at relatively large distances. Species with high visual acuity (0.11 degrees resolution) were able to distinguish the individual photophores of some counterilluminating signals at distances of several meters, thus breaking the camouflage. Depth and the presence or absence of moonlight strongly affected the spectrum of the background light, particularly near the surface. The increased variability near the surface was partially offset by the higher contrast attenuation at shallow depths, which reduced the sighting distance of mismatches. This research has implications for the study of spatial resolution, contrast sensitivity, and color discrimination in deep-sea visual systems.

  6. Visualization of upconverting nanoparticles in strongly scattering media

    PubMed Central

    Khaydukov, E. V.; Semchishen, V. A.; Seminogov, V. N.; Nechaev, A. V.; Zvyagin, A. V.; Sokolov, V. I.; Akhmanov, A. S.; Panchenko, V. Ya.

    2014-01-01

    Optical visualization systems are needed in medical applications for determining the localization of deep-seated luminescent markers in biotissues. The spatial resolution of such systems is limited by the scattering of the tissues. We present a novel epi-luminescent technique, which allows a 1.8-fold increase in the lateral spatial resolution in determining the localization of markers lying deep in a scattering medium compared to the traditional visualization techniques. This goal is attained by using NaYF4:Yb3+Tm3+@NaYF4 core/shell nanoparticles and special optical fiber probe with combined channels for the excitation and detection of anti-Stokes luminescence signals. PMID:24940552

  7. No Evidence for an Item Limit in Change Detection (Open Access)

    DTIC Science & Technology

    2013-02-28

    memory : a reconsideration of mental storage capacity. Behav Brain Sci 24: 87–114. 17. Eng HY, Chen D, Jiang Y (2005) Visual working memory for simple...working memory can hold no more than a fixed number of items (‘‘item-limit models’’). Recent findings force us to consider the alternative view that working... memory is limited by the precision in stimulus encoding, with mean precision decreasing with increasing set size (‘‘continuous-resource models

  8. 2D Fast Vessel Visualization Using a Vessel Wall Mask Guiding Fine Vessel Detection

    PubMed Central

    Raptis, Sotirios; Koutsouris, Dimitris

    2010-01-01

    The paper addresses the fine retinal-vessel's detection issue that is faced in diagnostic applications and aims at assisting in better recognizing fine vessel anomalies in 2D. Our innovation relies in separating key visual features vessels exhibit in order to make the diagnosis of eventual retinopathologies easier to detect. This allows focusing on vessel segments which present fine changes detectable at different sampling scales. We advocate that these changes can be addressed as subsequent stages of the same vessel detection procedure. We first carry out an initial estimate of the basic vessel-wall's network, define the main wall-body, and then try to approach the ridges and branches of the vasculature's using fine detection. Fine vessel screening looks into local structural inconsistencies in vessels properties, into noise, or into not expected intensity variations observed inside pre-known vessel-body areas. The vessels are first modelled sufficiently but not precisely by their walls with a tubular model-structure that is the result of an initial segmentation. This provides a chart of likely Vessel Wall Pixels (VWPs) yielding a form of a likelihood vessel map mainly based on gradient filter's intensity and spatial arrangement parameters (e.g., linear consistency). Specific vessel parameters (centerline, width, location, fall-away rate, main orientation) are post-computed by convolving the image with a set of pre-tuned spatial filters called Matched Filters (MFs). These are easily computed as Gaussian-like 2D forms that use a limited range sub-optimal parameters adjusted to the dominant vessel characteristics obtained by Spatial Grey Level Difference statistics limiting the range of search into vessel widths of 16, 32, and 64 pixels. Sparse pixels are effectively eliminated by applying a limited range Hough Transform (HT) or region growing. Major benefits are limiting the range of parameters, reducing the search-space for post-convolution to only masked regions, representing almost 2% of the 2D volume, good speed versus accuracy/time trade-off. Results show the potentials of our approach in terms of time for detection ROC analysis and accuracy of vessel pixel (VP) detection. PMID:20706682

  9. Visual and highly sensitive detection of cancer cells by a colorimetric aptasensor based on cell-triggered cyclic enzymatic signal amplification.

    PubMed

    Zhang, Xianxia; Xiao, Kunyi; Cheng, Liwei; Chen, Hui; Liu, Baohong; Zhang, Song; Kong, Jilie

    2014-06-03

    Rapid and efficient detection of cancer cells at their earliest stages is one of the central challenges in cancer diagnostics. We developed a simple, cost-effective, and highly sensitive colorimetric method for visually detecting rare cancer cells based on cell-triggered cyclic enzymatic signal amplification (CTCESA). In the absence of target cells, hairpin aptamer probes (HAPs) and linker DNAs stably coexist in solution, and the linker DNA assembles DNA-AuNPs, producing a purple solution. In the presence of target cells, the specific binding of HAPs to the target cells triggers a conformational switch that results in linker DNA hybridization and cleavage by nicking endonuclease-strand scission cycles. Consequently, the cleaved fragments of linker DNA can no longer assemble into DNA-AuNPs, resulting in a red color. UV-vis spectrometry and photograph analyses demonstrated that this CTCESA-based method exhibited selective and sensitive colorimetric responses to the presence of target CCRF-CEM cells, which could be detected by the naked eye. The linear response for CCRF-CEM cells in a concentration range from 10(2) to 10(4) cells was obtained with a detection limit of 40 cells, which is approximately 20 times lower than the detection limit of normal AuNP-based methods without amplification. Given the high specificity and sensitivity of CTCESA, this colorimetric method provides a sensitive, label-free, and cost-effective approach for early cancer diagnosis and point-to-care applications.

  10. Visualizing dopamine released from living cells using a nanoplasmonic probe

    NASA Astrophysics Data System (ADS)

    Qin, W. W.; Wang, S. P.; Li, J.; Peng, T. H.; Xu, Y.; Wang, K.; Shi, J. Y.; Fan, C. H.; Li, D.

    2015-09-01

    We report the development of an ultrasensitive nanoplasmonic probe for discriminative detection and imaging of dopamine released from living cells. The sensing mechanism is based on the dopamine-induced seeded-growth of Au nanoparticles (Au NPs) that leads to the shift of the plasmon band. This platform allows for the detection of dopamine with a detection limit down to 0.25 pM within 1 min. This nanoplasmonic assay is further applied to visualize the release of dopamine from living rat pheochromocytoma (PC12) cells under ATP-stimulation with dark-field microscopy (DFM). The DFM results together with real time fluorescence imaging of PC12 cells stained with the Fluo calcium indicator, suggested that ATP stimulated-release of dopamine is concomitant with the Ca2+ influx, and the influx of Ca2+ is through ATP-activated channels instead of the voltage-gated Ca2+ channel (VGC).We report the development of an ultrasensitive nanoplasmonic probe for discriminative detection and imaging of dopamine released from living cells. The sensing mechanism is based on the dopamine-induced seeded-growth of Au nanoparticles (Au NPs) that leads to the shift of the plasmon band. This platform allows for the detection of dopamine with a detection limit down to 0.25 pM within 1 min. This nanoplasmonic assay is further applied to visualize the release of dopamine from living rat pheochromocytoma (PC12) cells under ATP-stimulation with dark-field microscopy (DFM). The DFM results together with real time fluorescence imaging of PC12 cells stained with the Fluo calcium indicator, suggested that ATP stimulated-release of dopamine is concomitant with the Ca2+ influx, and the influx of Ca2+ is through ATP-activated channels instead of the voltage-gated Ca2+ channel (VGC). Electronic supplementary information (ESI) available: Fig. S1-S4 and Table S1. See DOI: 10.1039/c5nr04433b

  11. Visual Literacy in Preservice Teachers: a Case Study in Biology

    NASA Astrophysics Data System (ADS)

    Ruiz-Gallardo, José Reyes; García Fernández, Beatriz; Mateos Jiménez, Antonio

    2017-07-01

    In this study, we explore the competence of preservice teachers (n = 161) in labelling and creating new cross-sectional human diagrams, based on anatomy knowledge depicted in longitudinal sections. Using educational standards to assess visual literacy and ad hoc open questions, results indicate limited skills for both tasks. However, their competence is particularly poor creating diagrams, where shortcomings were observed not only in visual literacy but in content knowledge. We discuss the misconceptions detected during these assessments. Visual literacy training should be strengthened for these students, as it is a skill that is especially important for future teachers to use in learning, assessing, and reflecting on content in science education. This is particularly important in preservice teachers since they should be fluent in the use of visual teaching tools in teaching anatomy and other content in the biology curriculum.

  12. Small UAS Detect and Avoid Requirements Necessary for Limited Beyond Visual Line of Sight (BVLOS) Operations

    DOT National Transportation Integrated Search

    2017-05-19

    Potential sUAS BVLOS operational scenarios/use cases and DAA approaches were collected through a number of industry wide data calls. Every 333 Exemption holder was solicited for this same information. Summary information from more than 5,000 exemptio...

  13. Posterior parietal cortex mediates encoding and maintenance processes in change blindness.

    PubMed

    Tseng, Philip; Hsu, Tzu-Yu; Muggleton, Neil G; Tzeng, Ovid J L; Hung, Daisy L; Juan, Chi-Hung

    2010-03-01

    It is commonly accepted that right posterior parietal cortex (PPC) plays an important role in updating spatial representations, directing visuospatial attention, and planning actions. However, recent studies suggest that right PPC may also be involved in processes that are more closely associated with our visual awareness as its activation level positively correlates with successful conscious change detection (Beck, D.M., Rees, G., Frith, C.D., & Lavie, N. (2001). Neural correlates of change detection and change blindness. Nature Neuroscience, 4, 645-650.). Furthermore, disruption of its activity increases the occurrences of change blindness, thus suggesting a causal role for right PPC in change detection (Beck, D.M., Muggleton, N., Walsh, V., & Lavie, N. (2006). Right parietal cortex plays a critical role in change blindness. Cerebral Cortex, 16, 712-717.). In the context of a 1-shot change detection paradigm, we applied transcranial magnetic stimulation (TMS) during different time intervals to elucidate the temporally precise involvement of PPC in change detection. While subjects attempted to detect changes between two image sets separated by a brief time interval, TMS was applied either during the presentation of picture 1 when subjects were encoding and maintaining information into visual short-term memory, or picture 2 when subjects were retrieving information relating to picture 1 and comparing it to picture 2. Our results show that change blindness occurred more often when TMS was applied during the viewing of picture 1, which implies that right PPC plays a crucial role in the processes of encoding and maintaining information in visual short-term memory. In addition, since our stimuli did not involve changes in spatial locations, our findings also support previous studies suggesting that PPC may be involved in the processes of encoding non-spatial visual information (Todd, J.J. & Marois, R. (2004). Capacity limit of visual short-term memory in human posterior parietal cortex. Nature, 428, 751-754.). Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  14. Performance characteristics of a visual-search human-model observer with sparse PET image data

    NASA Astrophysics Data System (ADS)

    Gifford, Howard C.

    2012-02-01

    As predictors of human performance in detection-localization tasks, statistical model observers can have problems with tasks that are primarily limited by target contrast or structural noise. Model observers with a visual-search (VS) framework may provide a more reliable alternative. This framework provides for an initial holistic search that identifies suspicious locations for analysis by a statistical observer. A basic VS observer for emission tomography focuses on hot "blobs" in an image and uses a channelized nonprewhitening (CNPW) observer for analysis. In [1], we investigated this model for a contrast-limited task with SPECT images; herein, a statisticalnoise limited task involving PET images is considered. An LROC study used 2D image slices with liver, lung and soft-tissue tumors. Human and model observers read the images in coronal, sagittal and transverse display formats. The study thus measured the detectability of tumors in a given organ as a function of display format. The model observers were applied under several task variants that tested their response to structural noise both at the organ boundaries alone and over the organs as a whole. As measured by correlation with the human data, the VS observer outperformed the CNPW scanning observer.

  15. Visual loop-mediated isothermal amplification (LAMP) for the rapid diagnosis of Enterocytozoon hepatopenaei (EHP) infection.

    PubMed

    T, Sathish Kumar; A, Navaneeth Krishnan; J, Joseph Sahaya Rajan; M, Makesh; K P, Jithendran; S V, Alavandi; K K, Vijayan

    2018-05-01

    The emerging microsporidian parasite Enterocytozoon hepatopenaei (EHP), the causative agent of hepatopancreatic microsporidiosis, has been widely reported in shrimp-farming countries. EHP infection can be detected by light microscopy observation of spores (1.7 × 1 μm) in stained hepatopancreas (HP) tissue smears, HP tissue sections, and fecal samples. EHP can also be detected by polymerase chain reaction (PCR) targeting the small subunit (SSU) ribosomal RNA (rRNA) gene or the spore wall protein gene (SWP). In this study, a rapid, sensitive, specific, and closed tube visual loop-mediated isothermal amplification (LAMP) protocol combined with FTA cards was developed for the diagnosis of EHP. LAMP primers were designed based on the SSU rRNA gene of EHP. The target sequence of EHP was amplified at constant temperature of 65 °C for 45 min and amplified LAMP products were visually detected in a closed tube system by using SYBR™ green I dye. Detection limit of this LAMP protocol was ten copies. Field and clinical applicability of this assay was evaluated using 162 field samples including 106 HP tissue samples and 56 fecal samples collected from shrimp farms. Out of 162 samples, EHP could be detected in 62 samples (47 HP samples and 15 fecal samples). When compared with SWP-PCR as the gold standard, this EHP LAMP assay had 95.31% sensitivity, 98.98% specificity, and a kappa value of 0.948. This simple, closed tube, clinically evaluated visual LAMP assay has great potential for diagnosing EHP at the farm level, particularly under low-resource circumstances.

  16. Multimodal cues provide redundant information for bumblebees when the stimulus is visually salient, but facilitate red target detection in a naturalistic background

    PubMed Central

    Corcobado, Guadalupe; Trillo, Alejandro

    2017-01-01

    Our understanding of how floral visitors integrate visual and olfactory cues when seeking food, and how background complexity affects flower detection is limited. Here, we aimed to understand the use of visual and olfactory information for bumblebees (Bombus terrestris terrestris L.) when seeking flowers in a visually complex background. To explore this issue, we first evaluated the effect of flower colour (red and blue), size (8, 16 and 32 mm), scent (presence or absence) and the amount of training on the foraging strategy of bumblebees (accuracy, search time and flight behaviour), considering the visual complexity of our background, to later explore whether experienced bumblebees, previously trained in the presence of scent, can recall and make use of odour information when foraging in the presence of novel visual stimuli carrying a familiar scent. Of all the variables analysed, flower colour had the strongest effect on the foraging strategy. Bumblebees searching for blue flowers were more accurate, flew faster, followed more direct paths between flowers and needed less time to find them, than bumblebees searching for red flowers. In turn, training and the presence of odour helped bees to find inconspicuous (red) flowers. When bees foraged on red flowers, search time increased with flower size; but search time was independent of flower size when bees foraged on blue flowers. Previous experience with floral scent enhances the capacity of detection of a novel colour carrying a familiar scent, probably by elemental association influencing attention. PMID:28898287

  17. A Portable Platform for Evaluation of Visual Performance in Glaucoma Patients

    PubMed Central

    Rosen, Peter N.; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Marvasti, Amir H.; Medeiros, Felipe A.

    2015-01-01

    Purpose To propose a new tablet-enabled test for evaluation of visual performance in glaucoma, the PERformance CEntered Portable Test (PERCEPT), and to evaluate its ability to predict history of falls and motor vehicle crashes. Design Cross-sectional study. Methods The study involved 71 patients with glaucomatous visual field defects on standard automated perimetry (SAP) and 59 control subjects. The PERCEPT was based on the concept of increasing visual task difficulty to improve detection of central visual field losses in glaucoma patients. Subjects had to perform a foveal 8-alternative-forced-choice orientation discrimination task, while detecting a simultaneously presented peripheral stimulus within a limited presentation time. Subjects also underwent testing with the Useful Field of View (UFOV) divided attention test. The ability to predict history of motor vehicle crashes and falls was investigated by odds ratios and incident-rate ratios, respectively. Results When adjusted for age, only the PERCEPT processing speed parameter showed significantly larger values in glaucoma compared to controls (difference: 243ms; P<0.001). PERCEPT results had a stronger association with history of motor vehicle crashes and falls than UFOV. Each 1 standard deviation increase in PERCEPT processing speed was associated with an odds ratio of 2.69 (P = 0.003) for predicting history of motor vehicle crashes and with an incident-rate ratio of 1.95 (P = 0.003) for predicting history of falls. Conclusion A portable platform for testing visual function was able to detect functional deficits in glaucoma, and its results were significantly associated with history of involvement in motor vehicle crashes and history of falls. PMID:26445501

  18. An insect-inspired model for visual binding II: functional analysis and visual attention.

    PubMed

    Northcutt, Brandon D; Higgins, Charles M

    2017-04-01

    We have developed a neural network model capable of performing visual binding inspired by neuronal circuitry in the optic glomeruli of flies: a brain area that lies just downstream of the optic lobes where early visual processing is performed. This visual binding model is able to detect objects in dynamic image sequences and bind together their respective characteristic visual features-such as color, motion, and orientation-by taking advantage of their common temporal fluctuations. Visual binding is represented in the form of an inhibitory weight matrix which learns over time which features originate from a given visual object. In the present work, we show that information represented implicitly in this weight matrix can be used to explicitly count the number of objects present in the visual image, to enumerate their specific visual characteristics, and even to create an enhanced image in which one particular object is emphasized over others, thus implementing a simple form of visual attention. Further, we present a detailed analysis which reveals the function and theoretical limitations of the visual binding network and in this context describe a novel network learning rule which is optimized for visual binding.

  19. Neural correlates of change detection and change blindness in a working memory task.

    PubMed

    Pessoa, Luiz; Ungerleider, Leslie G

    2004-05-01

    Detecting changes in an ever-changing environment is highly advantageous, and this ability may be critical for survival. In the present study, we investigated the neural substrates of change detection in the context of a visual working memory task. Subjects maintained a sample visual stimulus in short-term memory for 6 s, and were asked to indicate whether a subsequent, test stimulus matched or did not match the original sample. To study change detection largely uncontaminated by attentional state, we compared correct change and correct no-change trials at test. Our results revealed that correctly detecting a change was associated with activation of a network comprising parietal and frontal brain regions, as well as activation of the pulvinar, cerebellum, and inferior temporal gyrus. Moreover, incorrectly reporting a change when none occurred led to a very similar pattern of activations. Finally, few regions were differentially activated by trials in which a change occurred but subjects failed to detect it (change blindness). Thus, brain activation was correlated with a subject's report of a change, instead of correlated with the physical change per se. We propose that frontal and parietal regions, possibly assisted by the cerebellum and the pulvinar, might be involved in controlling the deployment of attention to the location of a change, thereby allowing further processing of the visual stimulus. Visual processing areas, such as the inferior temporal gyrus, may be the recipients of top-down feedback from fronto-parietal regions that control the reactive deployment of attention, and thus exhibit increased activation when a change is reported (irrespective of whether it occurred or not). Whereas reporting that a change occurred, be it correctly or incorrectly, was associated with strong activation in fronto-parietal sites, change blindness appears to involve very limited territories.

  20. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    NASA Astrophysics Data System (ADS)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of applying this CAD-guided high-resolution microscopic image scanning system to prescreen and select ROIs that may contain analyzable metaphase chromosome cells. The success and the further improvement of this automated scanning system may have great impact on the future clinical practice in genetic laboratories to detect and diagnose diseases.

  1. Eccentric Macular Hole after Pars Plana Vitrectomy for Epiretinal Membrane Without Internal Limiting Membrane Peeling: A Case Report.

    PubMed

    Garnavou-Xirou, Christina; Xirou, Tina; Kabanarou, Stamatina; Gkizis, Ilias; Velissaris, Stavros; Chatziralli, Irini

    2017-12-01

    Postoperative eccentric macular hole formation is an uncommon complication after pars plana vitrectomy (PPV) without internal limiting membrane (ILM) peeling for the treatment of epiretinal membrane (ERM). We present a case of eccentric macular hole formation after PPV for ERM without ILM peeling. A 68-year-old male patient presented with ERM and visual acuity of 6/24 in his left eye. He underwent 23-gauge PPV without ILM peeling for treatment of ERM. One week postoperatively the retina was attached and the epiretinal membrane was successfully removed, while visual acuity was 6/9. One month after PPV, a single eccentric retinal hole below the macula was detected using fundoscopy and subsequently confirmed by optical coherence tomography. At this time the visual acuity was 6/9 and the patient reported no symptoms. No further intervention was attempted and at the 9-month follow-up, the visual acuity and the size of the eccentric macular hole remained stable. Eccentric macular holes can be developed after PPV even without ILM peeling and are usually managed conservatively by observation.

  2. More insight into the interplay of response selection and visual attention in dual-tasks: masked visual search and response selection are performed in parallel.

    PubMed

    Reimer, Christina B; Schubert, Torsten

    2017-09-15

    Both response selection and visual attention are limited in capacity. According to the central bottleneck model, the response selection processes of two tasks in a dual-task situation are performed sequentially. In conjunction search, visual attention is required to select the items and to bind their features (e.g., color and form), which results in a serial search process. Search time increases as items are added to the search display (i.e., set size effect). When the search display is masked, visual attention deployment is restricted to a brief period of time and target detection decreases as a function of set size. Here, we investigated whether response selection and visual attention (i.e., feature binding) rely on a common or on distinct capacity limitations. In four dual-task experiments, participants completed an auditory Task 1 and a conjunction search Task 2 that were presented with an experimentally modulated temporal interval between them (Stimulus Onset Asynchrony, SOA). In Experiment 1, Task 1 was a two-choice discrimination task and the conjunction search display was not masked. In Experiment 2, the response selection difficulty in Task 1 was increased to a four-choice discrimination and the search task was the same as in Experiment 1. We applied the locus-of-slack method in both experiments to analyze conjunction search time, that is, we compared the set size effects across SOAs. Similar set size effects across SOAs (i.e., additive effects of SOA and set size) would indicate sequential processing of response selection and visual attention. However, a significantly smaller set size effect at short SOA compared to long SOA (i.e., underadditive interaction of SOA and set size) would indicate parallel processing of response selection and visual attention. In both experiments, we found underadditive interactions of SOA and set size. In Experiments 3 and 4, the conjunction search display in Task 2 was masked. Task 1 was the same as in Experiments 1 and 2, respectively. In both experiments, the d' analysis revealed that response selection did not affect target detection. Overall, Experiments 1-4 indicated that neither the response selection difficulty in the auditory Task 1 (i.e., two-choice vs. four-choice) nor the type of presentation of the search display in Task 2 (i.e., not masked vs. masked) impaired parallel processing of response selection and conjunction search. We concluded that in general, response selection and visual attention (i.e., feature binding) rely on distinct capacity limitations.

  3. Attentional gain and processing capacity limits predict the propensity to neglect unexpected visual stimuli.

    PubMed

    Papera, Massimiliano; Richards, Anne

    2016-05-01

    Exogenous allocation of attentional resources allows the visual system to encode and maintain representations of stimuli in visual working memory (VWM). However, limits in the processing capacity to allocate resources can prevent unexpected visual stimuli from gaining access to VWM and thereby to consciousness. Using a novel approach to create unbiased stimuli of increasing saliency, we investigated visual processing during a visual search task in individuals who show a high or low propensity to neglect unexpected stimuli. When propensity to inattention is high, ERP recordings show a diminished amplification concomitantly with a decrease in theta band power during the N1 latency, followed by a poor target enhancement during the N2 latency. Furthermore, a later modulation in the P3 latency was also found in individuals showing propensity to visual neglect, suggesting that more effort is required for conscious maintenance of visual information in VWM. Effects during early stages of processing (N80 and P1) were also observed suggesting that sensitivity to contrasts and medium-to-high spatial frequencies may be modulated by low-level saliency (albeit no statistical group differences were found). In accordance with the Global Workplace Model, our data indicate that a lack of resources in low-level processors and visual attention may be responsible for the failure to "ignite" a state of high-level activity spread across several brain areas that is necessary for stimuli to access awareness. These findings may aid in the development of diagnostic tests and intervention to detect/reduce inattention propensity to visual neglect of unexpected stimuli. © 2016 Society for Psychophysiological Research.

  4. Detection and Monitoring of Oil Spills Using Moderate/High-Resolution Remote Sensing Images.

    PubMed

    Li, Ying; Cui, Can; Liu, Zexi; Liu, Bingxin; Xu, Jin; Zhu, Xueyuan; Hou, Yongchao

    2017-07-01

    Current marine oil spill detection and monitoring methods using high-resolution remote sensing imagery are quite limited. This study presented a new bottom-up and top-down visual saliency model. We used Landsat 8, GF-1, MAMS, HJ-1 oil spill imagery as dataset. A simplified, graph-based visual saliency model was used to extract bottom-up saliency. It could identify the regions with high visual saliency object in the ocean. A spectral similarity match model was used to obtain top-down saliency. It could distinguish oil regions and exclude the other salient interference by spectrums. The regions of interest containing oil spills were integrated using these complementary saliency detection steps. Then, the genetic neural network was used to complete the image classification. These steps increased the speed of analysis. For the test dataset, the average running time of the entire process to detect regions of interest was 204.56 s. During image segmentation, the oil spill was extracted using a genetic neural network. The classification results showed that the method had a low false-alarm rate (high accuracy of 91.42%) and was able to increase the speed of the detection process (fast runtime of 19.88 s). The test image dataset was composed of different types of features over large areas in complicated imaging conditions. The proposed model was proved to be robust in complex sea conditions.

  5. Quantifying the effect of colorization enhancement on mammogram images

    NASA Astrophysics Data System (ADS)

    Wojnicki, Paul J.; Uyeda, Elizabeth; Micheli-Tzanakou, Evangelia

    2002-04-01

    Current methods of radiological displays provide only grayscale images of mammograms. The limitation of the image space to grayscale provides only luminance differences and textures as cues for object recognition within the image. However, color can be an important and significant cue in the detection of shapes and objects. Increasing detection ability allows the radiologist to interpret the images in more detail, improving object recognition and diagnostic accuracy. Color detection experiments using our stimulus system, have demonstrated that an observer can only detect an average of 140 levels of grayscale. An optimally colorized image can allow a user to distinguish 250 - 1000 different levels, hence increasing potential image feature detection by 2-7 times. By implementing a colorization map, which follows the luminance map of the original grayscale images, the luminance profile is preserved and color is isolated as the enhancement mechanism. The effect of this enhancement mechanism on the shape, frequency composition and statistical characteristics of the Visual Evoked Potential (VEP) are analyzed and presented. Thus, the effectiveness of the image colorization is measured quantitatively using the Visual Evoked Potential (VEP).

  6. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys

    PubMed Central

    Hass, Charles A.; Angueyra, Juan M.; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D.

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity. PMID:26523737

  7. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys.

    PubMed

    Hass, Charles A; Angueyra, Juan M; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity.

  8. PROCRU: A model for analyzing crew procedures in approach to landing

    NASA Technical Reports Server (NTRS)

    Baron, S.; Muralidharan, R.; Lancraft, R.; Zacharias, G.

    1980-01-01

    A model for analyzing crew procedures in approach to landing is developed. The model employs the information processing structure used in the optimal control model and in recent models for monitoring and failure detection. Mechanisms are added to this basic structure to model crew decision making in this multi task environment. Decisions are based on probability assessments and potential mission impact (or gain). Sub models for procedural activities are included. The model distinguishes among external visual, instrument visual, and auditory sources of information. The external visual scene perception models incorporate limitations in obtaining information. The auditory information channel contains a buffer to allow for storage in memory until that information can be processed.

  9. Visual Detection of Canine Parvovirus Based on Loop-Mediated Isothermal Amplification Combined with Enzyme-Linked Immunosorbent Assay and with Lateral Flow Dipstick

    PubMed Central

    SUN, Yu-Ling; YEN, Chon-Ho; TU, Ching-Fu

    2013-01-01

    ABSTRACT Loop-mediated isothermal amplification (LAMP) combined with enzyme-linked immunosorbent assay (LAMP–ELISA) and with lateral flow dipstick (LAMP–LFD) are rapid, sensitive and specific methods for the visual detection of clinical pathogens. In this study, LAMP–ELISA and LAMP–LFD were developed for the visual detection of canine parvovirus (CPV). For LAMP, a set of four primers (biotin-labeled forward inner primers) was designed to specifically amplify a region of the VP2 gene of CPV. The optimum time and temperature for LAMP were 60 min and 65°C, respectively. The specific capture oligonucleotide probes, biotin-labeled CPV probe for LAMP–ELISA and fluorescein isothiocyanate-labeled CPV probe for LAMP–LFD were also designed for hybridization with LAMP amplicons on streptavidin-coated wells and LFD strips, respectively. For the comparison of detection sensitivity, conventional PCR and LAMP for CPV detection were also performed. The CPV detection limits by PCR, PCR–ELISA, LAMP, LAMP–ELISA and LAMP–LFD were 102, 102, 10−1, 10−1 and 10−1 TCID50/ml, respectively. In tests using artificially contaminated dog fecal samples, the samples with CPV inoculation levels of ≥1 TCID50/ml gave positive results by both LAMP–ELISA and LAMP–LFD. Our data indicated that both LAMP–ELISA and LAMP–LFD are promising as rapid, sensitive and specific methods for an efficient diagnosis of CPV infection. PMID:24334855

  10. Application of multispectral photography to mineral and land resources of South Carolina

    NASA Technical Reports Server (NTRS)

    Olson, N. K. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. Good results were obtained from using Skylab photography in conjunction with LANDSAT imagery for visual interpretation of various geologic features, particularly lineaments. It was concluded that visual interpretation alone of Skylab photographs was quite limited, and much of this was because of the low contrast, heavily vegetated terrain in southeastern United States. Lineaments of major structural features are detectable but subtle. An intimate knowledge of the geologic field relationships is needed before a meaningful analysis is feasible using current satellite photography alone.

  11. Machine Detection of Enhanced Electromechanical Energy Conversion in PbZr 0.2Ti 0.8O 3 Thin Films

    DOE PAGES

    Agar, Joshua C.; Cao, Ye; Naul, Brett; ...

    2018-05-28

    Many energy conversion, sensing, and microelectronic applications based on ferroic materials are determined by the domain structure evolution under applied stimuli. New hyperspectral, multidimensional spectroscopic techniques now probe dynamic responses at relevant length and time scales to provide an understanding of how these nanoscale domain structures impact macroscopic properties. Such approaches, however, remain limited in use because of the difficulties that exist in extracting and visualizing scientific insights from these complex datasets. Using multidimensional band-excitation scanning probe spectroscopy and adapting tools from both computer vision and machine learning, an automated workflow is developed to featurize, detect, and classify signatures ofmore » ferroelectric/ferroelastic switching processes in complex ferroelectric domain structures. This approach enables the identification and nanoscale visualization of varied modes of response and a pathway to statistically meaningful quantification of the differences between those modes. Lastly, among other things, the importance of domain geometry is spatially visualized for enhancing nanoscale electromechanical energy conversion.« less

  12. Machine Detection of Enhanced Electromechanical Energy Conversion in PbZr 0.2Ti 0.8O 3 Thin Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agar, Joshua C.; Cao, Ye; Naul, Brett

    Many energy conversion, sensing, and microelectronic applications based on ferroic materials are determined by the domain structure evolution under applied stimuli. New hyperspectral, multidimensional spectroscopic techniques now probe dynamic responses at relevant length and time scales to provide an understanding of how these nanoscale domain structures impact macroscopic properties. Such approaches, however, remain limited in use because of the difficulties that exist in extracting and visualizing scientific insights from these complex datasets. Using multidimensional band-excitation scanning probe spectroscopy and adapting tools from both computer vision and machine learning, an automated workflow is developed to featurize, detect, and classify signatures ofmore » ferroelectric/ferroelastic switching processes in complex ferroelectric domain structures. This approach enables the identification and nanoscale visualization of varied modes of response and a pathway to statistically meaningful quantification of the differences between those modes. Lastly, among other things, the importance of domain geometry is spatially visualized for enhancing nanoscale electromechanical energy conversion.« less

  13. Digital implementation of a neural network for imaging

    NASA Astrophysics Data System (ADS)

    Wood, Richard; McGlashan, Alex; Yatulis, Jay; Mascher, Peter; Bruce, Ian

    2012-10-01

    This paper outlines the design and testing of a digital imaging system that utilizes an artificial neural network with unsupervised and supervised learning to convert streaming input (real time) image space into parameter space. The primary objective of this work is to investigate the effectiveness of using a neural network to significantly reduce the information density of streaming images so that objects can be readily identified by a limited set of primary parameters and act as an enhanced human machine interface (HMI). Many applications are envisioned including use in biomedical imaging, anomaly detection and as an assistive device for the visually impaired. A digital circuit was designed and tested using a Field Programmable Gate Array (FPGA) and an off the shelf digital camera. Our results indicate that the networks can be readily trained when subject to limited sets of objects such as the alphabet. We can also separate limited object sets with rotational and positional invariance. The results also show that limited visual fields form with only local connectivity.

  14. Detection of Entamoeba histolytica by Recombinase Polymerase Amplification

    PubMed Central

    Nair, Gayatri; Rebolledo, Mauricio; White, A. Clinton; Crannell, Zachary; Richards-Kortum, R. Rebecca; Pinilla, A. Elizabeth; Ramírez, Juan David; López, M. Consuelo; Castellanos-Gonzalez, Alejandro

    2015-01-01

    Amebiasis is an important cause of diarrheal disease worldwide and has been associated with childhood malnutrition. Traditional microscopy approaches are neither sensitive nor specific for Entamoeba histolytica. Antigen assays are more specific, but many cases are missed unless tested by molecular methods. Although polymerase chain reaction (PCR) is effective, the need for sophisticated, expensive equipment, infrastructure, and trained personnel limits its usefulness, especially in the resource-limited, endemic areas. Here, we report development of a recombinase polymerase amplification (RPA) method to detect E. histolytica specifically. Using visual detection by lateral flow (LF), the test was highly sensitive and specific and could be performed without additional equipment. The availability of this inexpensive, sensitive, and field-applicable diagnostic test could facilitate rapid diagnosis and treatment of amebiasis in endemic regions. PMID:26123960

  15. On the relationship between human search strategies, conspicuity, and search performance

    NASA Astrophysics Data System (ADS)

    Hogervorst, Maarten A.; Bijl, Piet; Toet, Alexander

    2005-05-01

    We determined the relationship between search performance with a limited field of view (FOV) and several scanning- and scene parameters in human observer experiments. The observers (38 trained army scouts) searched through a large search sector for a target (a camouflaged person) on a heath. From trial to trial the target appeared at a different location. With a joystick the observers scanned through a panoramic image (displayed on a PC-monitor) while the scan path was registered. Four conditions were run differing in sensor type (visual or thermal infrared) and window size (large or small). In conditions with a small window size the zoom option could be used. Detection performance was highly dependent on zoom factor and deteriorated when scan speed increased beyond a threshold value. Moreover, the distribution of scan speeds scales with the threshold speed. This indicates that the observers are aware of their limitations and choose a (near) optimal search strategy. We found no correlation between the fraction of detected targets and overall search time for the individual observers, indicating that both are independent measures of individual search performance. Search performance (fraction detected, total search time, time in view for detection) was found to be strongly related to target conspicuity. Moreover, we found the same relationship between search performance and conspicuity for visual and thermal targets. This indicates that search performance can be predicted directly by conspicuity regardless of the sensor type.

  16. Visual inspection of cervix with acetic acid: a good alternative to pap smear for cervical cancer screening in resource-limited setting.

    PubMed

    Khan, Momna; Sultana, Syeda Seema; Jabeen, Nigar; Arain, Uzma; Khans, Salma

    2015-02-01

    To determine the diagnostic accuracy of visual inspection of cervix using 3% acetic acid as a screening test for early detection of cervical cancer taking histopathology as the gold standard. The cross-sectional study was conducted at Civil Hospital Karachi from July 1 to December 31, 2012 and comprised all sexually active women aged 19-60 years. During speculum examination 3% acetic acid was applied over the cervix with the help of cotton swab. The observations were noted as positive or negative on visual inspection of the cervix after acetic acid application according to acetowhite changes. Colposcopy-guided cervical biopsy was done in patients with positive or abnormal looking cervix. Colposcopic-directed biopsy was taken as the gold standard to assess visual inspection readings. SPSS 17 was used for statistical analysis. There were 500 subjects with a mean age of 35.74 ± 9.64 years. Sensitivity, specifically, positive predicted value, negative predicted value of visual inspection of the cervix after acetic acid application was 93.5%, 95.8%, 76.3%, 99%, and the diagnostic accuracy was 95.6%. Visual inspection of the cervix after acetic acid application is an effective method of detecting pre-invasive phase of cervical cancer and a good alternative to cytological screening for cervical cancer in resource-poor setting like Pakistan and can reduce maternal morbidity and mortality.

  17. Quality labeled faces in the wild (QLFW): a database for studying face recognition in real-world environments

    NASA Astrophysics Data System (ADS)

    Karam, Lina J.; Zhu, Tong

    2015-03-01

    The varying quality of face images is an important challenge that limits the effectiveness of face recognition technology when applied in real-world applications. Existing face image databases do not consider the effect of distortions that commonly occur in real-world environments. This database (QLFW) represents an initial attempt to provide a set of labeled face images spanning the wide range of quality, from no perceived impairment to strong perceived impairment for face detection and face recognition applications. Types of impairment include JPEG2000 compression, JPEG compression, additive white noise, Gaussian blur and contrast change. Subjective experiments are conducted to assess the perceived visual quality of faces under different levels and types of distortions and also to assess the human recognition performance under the considered distortions. One goal of this work is to enable automated performance evaluation of face recognition technologies in the presence of different types and levels of visual distortions. This will consequently enable the development of face recognition systems that can operate reliably on real-world visual content in the presence of real-world visual distortions. Another goal is to enable the development and assessment of visual quality metrics for face images and for face detection and recognition applications.

  18. FUNCTIONAL ASSESSMENT OF A CAMERA PHONE-BASED WAYFINDING SYSTEM OPERATED BY BLIND AND VISUALLY IMPAIRED USERS

    PubMed Central

    COUGHLAN, JAMES; MANDUCHI, ROBERTO

    2009-01-01

    We describe a wayfinding system for blind and visually impaired persons that uses a camera phone to determine the user's location with respect to color markers, posted at locations of interest (such as offices), which are automatically detected by the phone. The color marker signs are specially designed to be detected in real time in cluttered environments using computer vision software running on the phone; a novel segmentation algorithm quickly locates the borders of the color marker in each image, which allows the system to calculate how far the marker is from the phone. We present a model of how the user's scanning strategy (i.e. how he/she pans the phone left and right to find color markers) affects the system's ability to detect color markers given the limitations imposed by motion blur, which is always a possibility whenever a camera is in motion. Finally, we describe experiments with our system tested by blind and visually impaired volunteers, demonstrating their ability to reliably use the system to find locations designated by color markers in a variety of indoor and outdoor environments, and elucidating which search strategies were most effective for users. PMID:19960101

  19. Dual-color plasmonic enzyme-linked immunosorbent assay based on enzyme-mediated etching of Au nanoparticles

    NASA Astrophysics Data System (ADS)

    Guo, Longhua; Xu, Shaohua; Ma, Xiaoming; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2016-09-01

    Colorimetric enzyme-linked immunosorbent assay utilizing 3‧-3-5‧-5-tetramethylbenzidine(TMB) as the chromogenic substrate has been widely used in the hospital for the detection of all kinds of disease biomarkers. Herein, we demonstrate a strategy to change this single-color display into dual-color responses to improve the accuracy of visual inspection. Our investigation firstly reveals that oxidation state of 3‧-3-5‧-5-tetramethylbenzidine (TMB2+) can quantitatively etch gold nanoparticles. Therefore, the incorporation of gold nanoparticles into a commercial TMB-based ELISA kit could generate dual-color responses: the solution color varied gradually from wine red (absorption peak located at ~530 nm) to colorless, and then from colorless to yellow (absorption peak located at ~450 nm) with the increase amount of targets. These dual-color responses effectively improved the sensitivity as well as the accuracy of visual inspection. For example, the proposed dual-color plasmonic ELISA is demonstrated for the detection of prostate-specific antigen (PSA) in human serum with a visual limit of detection (LOD) as low as 0.0093 ng/mL.

  20. FUNCTIONAL ASSESSMENT OF A CAMERA PHONE-BASED WAYFINDING SYSTEM OPERATED BY BLIND AND VISUALLY IMPAIRED USERS.

    PubMed

    Coughlan, James; Manduchi, Roberto

    2009-06-01

    We describe a wayfinding system for blind and visually impaired persons that uses a camera phone to determine the user's location with respect to color markers, posted at locations of interest (such as offices), which are automatically detected by the phone. The color marker signs are specially designed to be detected in real time in cluttered environments using computer vision software running on the phone; a novel segmentation algorithm quickly locates the borders of the color marker in each image, which allows the system to calculate how far the marker is from the phone. We present a model of how the user's scanning strategy (i.e. how he/she pans the phone left and right to find color markers) affects the system's ability to detect color markers given the limitations imposed by motion blur, which is always a possibility whenever a camera is in motion. Finally, we describe experiments with our system tested by blind and visually impaired volunteers, demonstrating their ability to reliably use the system to find locations designated by color markers in a variety of indoor and outdoor environments, and elucidating which search strategies were most effective for users.

  1. Feature-Based Change Detection Reveals Inconsistent Individual Differences in Visual Working Memory Capacity.

    PubMed

    Ambrose, Joseph P; Wijeakumar, Sobanawartiny; Buss, Aaron T; Spencer, John P

    2016-01-01

    Visual working memory (VWM) is a key cognitive system that enables people to hold visual information in mind after a stimulus has been removed and compare past and present to detect changes that have occurred. VWM is severely capacity limited to around 3-4 items, although there are robust individual differences in this limit. Importantly, these individual differences are evident in neural measures of VWM capacity. Here, we capitalized on recent work showing that capacity is lower for more complex stimulus dimension. In particular, we asked whether individual differences in capacity remain consistent if capacity is shifted by a more demanding task, and, further, whether the correspondence between behavioral and neural measures holds across a shift in VWM capacity. Participants completed a change detection (CD) task with simple colors and complex shapes in an fMRI experiment. As expected, capacity was significantly lower for the shape dimension. Moreover, there were robust individual differences in behavioral estimates of VWM capacity across dimensions. Similarly, participants with a stronger BOLD response for color also showed a strong neural response for shape within the lateral occipital cortex, intraparietal sulcus (IPS), and superior IPS. Although there were robust individual differences in the behavioral and neural measures, we found little evidence of systematic brain-behavior correlations across feature dimensions. This suggests that behavioral and neural measures of capacity provide different views onto the processes that underlie VWM and CD. Recent theoretical approaches that attempt to bridge between behavioral and neural measures are well positioned to address these findings in future work.

  2. 'I didn't see that coming': simulated visual fields and driving hazard perception test performance.

    PubMed

    Glen, Fiona C; Smith, Nicholas D; Jones, Lee; Crabb, David P

    2016-09-01

    Evidence is limited regarding specific types of visual field loss associated with unsafe driving. We use novel gaze-contingent software to examine the effect of simulated visual field loss on computer-based driving hazard detection with the specific aim of testing the impact of scotomata located to the right and left of fixation. The 'hazard perception test' is a component of the UK driving licence examination, which measures speed of detecting 15 different hazards in a series of real-life driving films. We have developed a novel eye-tracking and computer set up capable of generating a realistic gaze-contingent scotoma simulation (GazeSS) overlaid on film content. Thirty drivers with healthy vision completed three versions of the hazard perception test in a repeated measures experiment. In two versions, GazeSS simulated a scotoma in the binocular field of view to the left or right of fixation. A third version was unmodified to establish baseline performance. Participants' mean baseline hazard perception test score was 51 ± 7 (out of 75). This reduced to 46 ± 9 and 46 ± 11 when completing the task with a binocular visual field defect located to the left and right of fixation, respectively. While the main effect of simulated visual field loss on performance was statistically significant (p = 0.007), there were no average differences in the experimental conditions where a scotoma was located in the binocular visual field to the right or left of fixation. Simulated visual field loss impairs driving hazard detection on a computer-based test. There was no statistically significant difference in average performance when the simulated scotoma was located to the right or left of fixation of the binocular visual field, but certain types of hazard caused more difficulties than others. © 2016 Optometry Australia.

  3. Automated detection of diabetic retinopathy: barriers to translation into clinical practice.

    PubMed

    Abramoff, Michael D; Niemeijer, Meindert; Russell, Stephen R

    2010-03-01

    Automated identification of diabetic retinopathy (DR), the primary cause of blindness and visual loss for those aged 18-65 years, from color images of the retina has enormous potential to increase the quality, cost-effectiveness and accessibility of preventative care for people with diabetes. Through advanced image analysis techniques, retinal images are analyzed for abnormalities that define and correlate with the severity of DR. Translating automated DR detection into clinical practice will require surmounting scientific and nonscientific barriers. Scientific concerns, such as DR detection limits compared with human experts, can be studied and measured. Ethical, legal and political issues can be addressed, but are difficult or impossible to measure. The primary objective of this review is to survey the methods, potential benefits and limitations of automated detection in order to better manage translation into clinical practice, based on extensive experience with the systems we have developed.

  4. Lesion classification using clinical and visual data fusion by multiple kernel learning

    NASA Astrophysics Data System (ADS)

    Kisilev, Pavel; Hashoul, Sharbell; Walach, Eugene; Tzadok, Asaf

    2014-03-01

    To overcome operator dependency and to increase diagnosis accuracy in breast ultrasound (US), a lot of effort has been devoted to developing computer-aided diagnosis (CAD) systems for breast cancer detection and classification. Unfortunately, the efficacy of such CAD systems is limited since they rely on correct automatic lesions detection and localization, and on robustness of features computed based on the detected areas. In this paper we propose a new approach to boost the performance of a Machine Learning based CAD system, by combining visual and clinical data from patient files. We compute a set of visual features from breast ultrasound images, and construct the textual descriptor of patients by extracting relevant keywords from patients' clinical data files. We then use the Multiple Kernel Learning (MKL) framework to train SVM based classifier to discriminate between benign and malignant cases. We investigate different types of data fusion methods, namely, early, late, and intermediate (MKL-based) fusion. Our database consists of 408 patient cases, each containing US images, textual description of complaints and symptoms filled by physicians, and confirmed diagnoses. We show experimentally that the proposed MKL-based approach is superior to other classification methods. Even though the clinical data is very sparse and noisy, its MKL-based fusion with visual features yields significant improvement of the classification accuracy, as compared to the image features only based classifier.

  5. Vision and Foraging in Cormorants: More like Herons than Hawks?

    PubMed Central

    White, Craig R.; Day, Norman; Butler, Patrick J.; Martin, Graham R.

    2007-01-01

    Background Great cormorants (Phalacrocorax carbo L.) show the highest known foraging yield for a marine predator and they are often perceived to be in conflict with human economic interests. They are generally regarded as visually-guided, pursuit-dive foragers, so it would be expected that cormorants have excellent vision much like aerial predators, such as hawks which detect and pursue prey from a distance. Indeed cormorant eyes appear to show some specific adaptations to the amphibious life style. They are reported to have a highly pliable lens and powerful intraocular muscles which are thought to accommodate for the loss of corneal refractive power that accompanies immersion and ensures a well focussed image on the retina. However, nothing is known of the visual performance of these birds and how this might influence their prey capture technique. Methodology/Principal Findings We measured the aquatic visual acuity of great cormorants under a range of viewing conditions (illuminance, target contrast, viewing distance) and found it to be unexpectedly poor. Cormorant visual acuity under a range of viewing conditions is in fact comparable to unaided humans under water, and very inferior to that of aerial predators. We present a prey detectability model based upon the known acuity of cormorants at different illuminances, target contrasts and viewing distances. This shows that cormorants are able to detect individual prey only at close range (less than 1 m). Conclusions/Significance We conclude that cormorants are not the aquatic equivalent of hawks. Their efficient hunting involves the use of specialised foraging techniques which employ brief short-distance pursuit and/or rapid neck extension to capture prey that is visually detected or flushed only at short range. This technique appears to be driven proximately by the cormorant's limited visual capacities, and is analogous to the foraging techniques employed by herons. PMID:17653266

  6. Isolating contour information from arbitrary images

    NASA Technical Reports Server (NTRS)

    Jobson, Daniel J.

    1989-01-01

    Aspects of natural vision (physiological and perceptual) serve as a basis for attempting the development of a general processing scheme for contour extraction. Contour information is assumed to be central to visual recognition skills. While the scheme must be regarded as highly preliminary, initial results do compare favorably with the visual perception of structure. The scheme pays special attention to the construction of a smallest scale circular difference-of-Gaussian (DOG) convolution, calibration of multiscale edge detection thresholds with the visual perception of grayscale boundaries, and contour/texture discrimination methods derived from fundamental assumptions of connectivity and the characteristics of printed text. Contour information is required to fall between a minimum connectivity limit and maximum regional spatial density limit at each scale. Results support the idea that contour information, in images possessing good image quality, is (centered at about 10 cyc/deg and 30 cyc/deg). Further, lower spatial frequency channels appear to play a major role only in contour extraction from images with serious global image defects.

  7. 46 CFR 161.002-2 - Types of fire-protective systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...

  8. Establishing the behavioural limits for countershaded camouflage.

    PubMed

    Penacchio, Olivier; Harris, Julie M; Lovell, P George

    2017-10-20

    Countershading is a ubiquitous patterning of animals whereby the side that typically faces the highest illumination is darker. When tuned to specific lighting conditions and body orientation with respect to the light field, countershading minimizes the gradient of light the body reflects by counterbalancing shadowing due to illumination, and has therefore classically been thought of as an adaptation for visual camouflage. However, whether and how crypsis degrades when body orientation with respect to the light field is non-optimal has never been studied. We tested the behavioural limits on body orientation for countershading to deliver effective visual camouflage. We asked human participants to detect a countershaded target in a simulated three-dimensional environment. The target was optimally coloured for crypsis in a reference orientation and was displayed at different orientations. Search performance dramatically improved for deviations beyond 15 degrees. Detection time was significantly shorter and accuracy significantly higher than when the target orientation matched the countershading pattern. This work demonstrates the importance of maintaining body orientation appropriate for the displayed camouflage pattern, suggesting a possible selective pressure for animals to orient themselves appropriately to enhance crypsis.

  9. Visual working memory capacity and the medial temporal lobe.

    PubMed

    Jeneson, Annette; Wixted, John T; Hopkins, Ramona O; Squire, Larry R

    2012-03-07

    Patients with medial temporal lobe (MTL) damage are sometimes impaired at remembering visual information across delays as short as a few seconds. Such impairments could reflect either impaired visual working memory capacity or impaired long-term memory (because attention has been diverted or because working memory capacity has been exceeded). Using a standard change-detection task, we asked whether visual working memory capacity is intact or impaired after MTL damage. Five patients with hippocampal lesions and one patient with large MTL lesions saw an array of 1, 2, 3, 4, or 6 colored squares, followed after 3, 4, or 8 s by a second array where one of the colored squares was cued. The task was to decide whether the cued square had the same color as the corresponding square in the first array or a different color. At the 1 s delay typically used to assess working memory capacity, patients performed as well as controls at all array sizes. At the longer delays, patients performed as well as controls at small array sizes, thought to be within the capacity limit, and worse than controls at large array sizes, thought to exceed the capacity limit. The findings suggest that visual working memory capacity in humans is intact after damage to the MTL structures and that damage to these structures impairs performance only when visual working memory is insufficient to support performance.

  10. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-01

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.

  11. Insect Detection of Small Targets Moving in Visual Clutter

    PubMed Central

    Barnett, Paul D; O'Carroll, David C

    2006-01-01

    Detection of targets that move within visual clutter is a common task for animals searching for prey or conspecifics, a task made even more difficult when a moving pursuer needs to analyze targets against the motion of background texture (clutter). Despite the limited optical acuity of the compound eye of insects, this challenging task seems to have been solved by their tiny visual system. Here we describe neurons found in the male hoverfly,Eristalis tenax, that respond selectively to small moving targets. Although many of these target neurons are inhibited by the motion of a background pattern, others respond to target motion within the receptive field under a surprisingly large range of background motion stimuli. Some neurons respond whether or not there is a speed differential between target and background. Analysis of responses to very small targets (smaller than the size of the visual field of single photoreceptors) or those targets with reduced contrast shows that these neurons have extraordinarily high contrast sensitivity. Our data suggest that rejection of background motion may result from extreme selectivity for small targets contrasting against local patches of the background, combined with this high sensitivity, such that background patterns rarely contain features that satisfactorily drive the neuron. PMID:16448249

  12. Recombinase Polymerase Amplification Combined with Lateral Flow Strip for Listeria monocytogenes Detection in Food.

    PubMed

    Du, Xin-Jun; Zang, Yu-Xuan; Liu, Hai-Bin; Li, Ping; Wang, Shuo

    2018-04-01

    Listeria monocytogenes is an important food-borne pathogenic bacterium that causes human disease, resulting in economic losses worldwide. The current detection methods for L. monocytogenes are not well suited for direct field testing because they involve complicated, time-consuming operations. A simple, efficient method is vital for L. monocytogenes detection. In this study, we combined isothermal recombinase polymerase amplification (RPA) with a lateral flow (LF) strip to rapidly and reliably detect L. monocytogenes. In the presence of biotin- and digoxin-modified primers, RPA produced numerous digoxin- and biotin-attached duplex DNA products. These products were detected on an LF strip via dual immunoreactions (digoxin on the duplex DNA reacted with the anti-digoxin antibody on the gold nanoparticle (Au-NP) and the biotin on the duplex DNA captured by the streptavidin on the LF test zone). The accumulation of Au-NPs produced characteristic bands, enabling the visual detection of L. monocytogenes without instrumentation. This assay could be used to detect L. monocytogenes within 15 min, including DNA amplification with RPA for 10 min at 39 °C and visualization of the amplicons by LF strips for 5 min. Experiments confirmed a detection limit as low as 300 fg of DNA and 1.5 × 10 1 CFU in pure cultures. Furthermore, RPA-LF exhibited no cross-reactions with pathogens. Evaluation of the method with food samples indicated that the detection limit was substantially improved to 1.5 × 10° CFU for the original bacterial content in 25 g/mL samples after enrichment for 6 hr. RPA-LF can be used as a sensitive and rapid detection technique for L. monocytogenes. Recombinase polymerase amplification (RPA) can amplify target DNA at 37 to 42 °C without a thermal cycler. Lateral flow (LF) strips are portable, cheap and easy to operate. RPA combined with LF strips to detect Listeria monocytogenes can be widely used in remote areas. © 2018 Institute of Food Technologists®.

  13. Non-verbal IQ is correlated with visual field advantages for short duration coherent motion detection in deaf signers with varied ASL exposure and etiologies of deafness.

    PubMed

    Samar, Vincent J; Parasnis, Ila

    2007-12-01

    Studies have reported a right visual field (RVF) advantage for coherent motion detection by deaf and hearing signers but not non-signers. Yet two studies [Bosworth R. G., & Dobkins, K. R. (2002). Visual field asymmetries for motion processing in deaf and hearing signers. Brain and Cognition, 49, 170-181; Samar, V. J., & Parasnis, I. (2005). Dorsal stream deficits suggest hidden dyslexia among deaf poor readers: Correlated evidence from reduced perceptual speed and elevated coherent motion detection thresholds. Brain and Cognition, 58, 300-311.] reported a small, non-significant RVF advantage for deaf signers when short duration motion stimuli were used (200-250 ms). Samar and Parasnis (2005) reported that this small RVF advantage became significant when non-verbal IQ was statistically controlled. This paper presents extended analyses of the correlation between non-verbal IQ and visual field asymmetries in the data set of Samar and Parasnis (2005). We speculate that this correlation might plausibly be driven by individual differences either in age of acquisition of American Sign Language (ASL) or in the degree of neurodevelopmental insult associated with various etiologies of deafness. Limited additional analyses are presented that indicate a need for further research on the cause of this apparent IQ-laterality relationship. Some potential implications of this relationship for lateralization studies of deaf signers are discussed. Controlling non-verbal IQ may improve the reliability of short duration coherent motion tasks to detect adaptive dorsal stream lateralization due to exposure to ASL in deaf research participants.

  14. Visual and efficient immunosensor technique for advancing biomedical applications of quantum dots on Salmonella detection and isolation

    NASA Astrophysics Data System (ADS)

    Tang, Feng; Pang, Dai-Wen; Chen, Zhi; Shao, Jian-Bo; Xiong, Ling-Hong; Xiang, Yan-Ping; Xiong, Yan; Wu, Kai; Ai, Hong-Wu; Zhang, Hui; Zheng, Xiao-Li; Lv, Jing-Rui; Liu, Wei-Yong; Hu, Hong-Bing; Mei, Hong; Zhang, Zhen; Sun, Hong; Xiang, Yun; Sun, Zi-Yong

    2016-02-01

    It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance.It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance. Electronic supplementary information (ESI) available: One additional figure (Fig. S1), two additional tables (Tables S1 and S2) and additional information. See DOI: 10.1039/c5nr07424j

  15. Terbium(III)/gold nanocluster conjugates: the development of a novel ratiometric fluorescent probe for mercury(II) and a paper-based visual sensor.

    PubMed

    Qi, Yan-Xia; Zhang, Min; Zhu, Anwei; Shi, Guoyue

    2015-08-21

    In this work, a novel ratiometric fluorescent probe was developed for rapid, highly accurate, sensitive and selective detection of mercury(II) (Hg(2+)) based on terbium(III)/gold nanocluster conjugates (Tb(3+)/BSA-AuNCs), in which bovine serum albumin capped gold nanoclusters (BSA-AuNCs) acted as the signal indicator and terbium(III) (Tb(3+)) was used as the build-in reference. Our proposed ratiometric fluorescent probe exhibited unique specificity toward Hg(2+) against other common environmentally and biologically important metal ions, and had high accuracy and sensitivity with a low detection limit of 1 nM. In addition, our proposed probe was effectively employed to detect Hg(2+) in the biological samples from the artificial Hg(2+)-infected rats. More significantly, an appealing paper-based visual sensor for Hg(2+) was designed by using filter paper embedded with Tb(3+)/BSA-AuNC conjugates, and we have further demonstrated its feasibility for facile fluorescent sensing of Hg(2+) in a visual format, in which only a handheld UV lamp is used. In the presence of Hg(2+), the paper-based visual sensor, illuminated by a handheld UV lamp, would undergo a distinct fluorescence color change from red to green, which can be readily observed with naked eyes even in trace Hg(2+) concentrations. The Tb(3+)/BSA-AuNC-derived paper-based visual sensor is cost-effective, portable, disposable and easy-to-use. This work unveiled a facile approach for accurate, sensitive and selective measuring of Hg(2+) with self-calibration.

  16. Fixation preference test: reliability for the detection of amblyopia in patients with strabismus and interexaminer agreement.

    PubMed

    Erkan Turan, Kadriye; Taylan Sekeroglu, Hande; Karahan, Sevilay; Sanac, Ali Sefik

    2017-12-01

    The purpose of this study was to analyze the reliability of the fixation preference test (FPT) in the detection of amblyopia, and to determine interexaminer agreement. Eighty patients whose visual acuity could be tested objectively and had a horizontal misalignment of more than 10 prism diopters were enrolled. The best corrected visual acuity (BCVA) and orthoptic findings were all recorded. Non-preferred eye in primary position and fixation preference grade were assessed independently by two masked experienced examiners. The primary outcome measures were reliability of FPT in terms of its correlation with BCVA and interexaminer agreement. There was no significant correlation between fixation preference grades and interocular visual acuity difference as well as the type and amount of deviation, the presence of fusion, stereopsis, anisometropia, and previous strabismus surgery for none of the examiners (p > 0.05 for all). Sensitivity was 52.0% for examiner 1 and 54.0% for examiner 2 while specificity was 50.0 and 46.7%, respectively. Interexaminer agreement was 76.7% (p < 0.001) for all patients. FPT is widely used in children particularly when the visual acuity cannot be determined in an objective manner. The test may not be accurate and reliable in the detection of amblyopia and also in predicting the visual acuity difference between both eyes, even though it was found to show a high degree of agreement between examiners. In conclusion, it should be kept in mind that the reliability of FPT may be limited and the results should be interpreted with caution and be supported by other tests.

  17. Processing of single-photon responses in the mammalian On and Off retinal pathways at the sensitivity limit of vision

    PubMed Central

    2017-01-01

    Visually guided behaviour at its sensitivity limit relies on single-photon responses originating in a small number of rod photoreceptors. For decades, researchers have debated the neural mechanisms and noise sources that underlie this striking sensitivity. To address this question, we need to understand the constraints arising from the retinal output signals provided by distinct retinal ganglion cell types. It has recently been shown in the primate retina that On and Off parasol ganglion cells, the cell types likely to underlie light detection at the absolute visual threshold, differ fundamentally not only in response polarity, but also in the way they handle single-photon responses originating in rods. The On pathway provides the brain with a thresholded, low-noise readout and the Off pathway with a noisy, linear readout. We outline the mechanistic basis of these different coding strategies and analyse their implications for detecting the weakest light signals. We show that high-fidelity, nonlinear signal processing in the On pathway comes with costs: more single-photon responses are lost and their propagation is delayed compared with the Off pathway. On the other hand, the responses of On ganglion cells allow better intensity discrimination compared with the Off ganglion cell responses near visual threshold. This article is part of the themed issue ‘Vision in dim light’. PMID:28193818

  18. Processing of single-photon responses in the mammalian On and Off retinal pathways at the sensitivity limit of vision.

    PubMed

    Takeshita, Daisuke; Smeds, Lina; Ala-Laurila, Petri

    2017-04-05

    Visually guided behaviour at its sensitivity limit relies on single-photon responses originating in a small number of rod photoreceptors. For decades, researchers have debated the neural mechanisms and noise sources that underlie this striking sensitivity. To address this question, we need to understand the constraints arising from the retinal output signals provided by distinct retinal ganglion cell types. It has recently been shown in the primate retina that On and Off parasol ganglion cells, the cell types likely to underlie light detection at the absolute visual threshold, differ fundamentally not only in response polarity, but also in the way they handle single-photon responses originating in rods. The On pathway provides the brain with a thresholded, low-noise readout and the Off pathway with a noisy, linear readout. We outline the mechanistic basis of these different coding strategies and analyse their implications for detecting the weakest light signals. We show that high-fidelity, nonlinear signal processing in the On pathway comes with costs: more single-photon responses are lost and their propagation is delayed compared with the Off pathway. On the other hand, the responses of On ganglion cells allow better intensity discrimination compared with the Off ganglion cell responses near visual threshold.This article is part of the themed issue 'Vision in dim light'. © 2017 The Authors.

  19. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    PubMed Central

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-01-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions. PMID:25199907

  20. Rapid detection of Cu(2+) by a paper-based microfluidic device coated with bovine serum albumin (BSA)-Au nanoclusters.

    PubMed

    Fang, Xueen; Zhao, Qianqian; Cao, Hongmei; Liu, Juan; Guan, Ming; Kong, Jilie

    2015-11-21

    In this work, bovine serum albumin (BSA)-Au nanoclusters were used to coat a paper-based microfluidic device. This device acted as a Cu(2+) biosensor that showed fluorescence quenching on detection of copper ions. The detection limit of this sensor could be adjusted by altering the water absorbing capacity of the device. Qualitative and semi-quantitative results could be obtained visually without the aid of any advanced instruments. This sensor could test Cu(2+) rapidly with high specificity and sensitivity, which would be useful for point-of-care testing (POCT).

  1. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    NASA Astrophysics Data System (ADS)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  2. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye.

    PubMed

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-09

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  3. A colloidal gold nanoparticle-based immunochromatographic test strip for rapid and convenient detection of Staphylococcus aureus.

    PubMed

    Niu, Kaili; Zheng, Xiaoping; Huang, Chusen; Xul, Kuan; Zhi, Yuan; Shen, Hebai; Jia, Nengqin

    2014-07-01

    An immunochromatographic test strip using gold nanoparticles-staphylococcus aureus monoclonal antibody conjugates was developed for the rapid and convenient detection of staphylococcus aureus based on a double-antibody sandwich format. The detection limit and the detection rate of this test strip is 10(3) CFU /mL and 98.7%, respectively. It could be used for the rapid detection of staphylococcus aureus in food and the results can be visually identified by the naked eye within 10 min. Compared with conventional bacterial detection methods, this developed immunochromatographic assay based test strip has several advantages including simple, fast, low-cost, favorable sensitivity and specificity, exhibiting a great potential for application in food safety control systems and clinical diagnosis.

  4. Flow Visualization of Density in a Cryogenic Wind Tunnel Using Planar Rayleigh and Raman Scattering

    NASA Technical Reports Server (NTRS)

    Herring, Gregory C.; Shirinzadeh, Behrooz

    2002-01-01

    Using a pulsed Nd:YAG laser (532 nm) and a gated, intensified charge-coupled device, planar Rayleigh and Raman scattering techniques have been used to visualize the unseeded Mach 0.2 flow density in a 0.3-meter transonic cryogenic wind tunnel. Detection limits are determined for density measurements by using both unseeded Rayleigh and Raman (N2 vibrational) methods. Seeding with CO2 improved the Rayleigh flow visualization at temperatures below 150 K. The seeded Rayleigh version was used to demonstrate the observation of transient flow features in a separated boundary layer region, which was excited with an oscillatory jet. Finally, a significant degradation of the laser light sheet, in this cryogenic facility, is discussed.

  5. Visual Search Elicits the Electrophysiological Marker of Visual Working Memory

    PubMed Central

    Emrich, Stephen M.; Al-Aidroos, Naseem; Pratt, Jay; Ferber, Susanne

    2009-01-01

    Background Although limited in capacity, visual working memory (VWM) plays an important role in many aspects of visually-guided behavior. Recent experiments have demonstrated an electrophysiological marker of VWM encoding and maintenance, the contralateral delay activity (CDA), which has been shown in multiple tasks that have both explicit and implicit memory demands. Here, we investigate whether the CDA is evident during visual search, a thoroughly-researched task that is a hallmark of visual attention but has no explicit memory requirements. Methodology/Principal Findings The results demonstrate that the CDA is present during a lateralized search task, and that it is similar in amplitude to the CDA observed in a change-detection task, but peaks slightly later. The changes in CDA amplitude during search were strongly correlated with VWM capacity, as well as with search efficiency. These results were paralleled by behavioral findings showing a strong correlation between VWM capacity and search efficiency. Conclusions/Significance We conclude that the activity observed during visual search was generated by the same neural resources that subserve VWM, and that this activity reflects the maintenance of previously searched distractors. PMID:19956663

  6. Multi-modal distraction: insights from children's limited attention.

    PubMed

    Matusz, Pawel J; Broadbent, Hannah; Ferrari, Jessica; Forrest, Benjamin; Merkley, Rebecca; Scerif, Gaia

    2015-03-01

    How does the multi-sensory nature of stimuli influence information processing? Cognitive systems with limited selective attention can elucidate these processes. Six-year-olds, 11-year-olds and 20-year-olds engaged in a visual search task that required them to detect a pre-defined coloured shape under conditions of low or high visual perceptual load. On each trial, a peripheral distractor that could be either compatible or incompatible with the current target colour was presented either visually, auditorily or audiovisually. Unlike unimodal distractors, audiovisual distractors elicited reliable compatibility effects across the two levels of load in adults and in the older children, but high visual load significantly reduced distraction for all children, especially the youngest participants. This study provides the first demonstration that multi-sensory distraction has powerful effects on selective attention: Adults and older children alike allocate attention to potentially relevant information across multiple senses. However, poorer attentional resources can, paradoxically, shield the youngest children from the deleterious effects of multi-sensory distraction. Furthermore, we highlight how developmental research can enrich the understanding of distinct mechanisms controlling adult selective attention in multi-sensory environments. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Detection of Entamoeba histolytica by Recombinase Polymerase Amplification.

    PubMed

    Nair, Gayatri; Rebolledo, Mauricio; White, A Clinton; Crannell, Zachary; Richards-Kortum, R Rebecca; Pinilla, A Elizabeth; Ramírez, Juan David; López, M Consuelo; Castellanos-Gonzalez, Alejandro

    2015-09-01

    Amebiasis is an important cause of diarrheal disease worldwide and has been associated with childhood malnutrition. Traditional microscopy approaches are neither sensitive nor specific for Entamoeba histolytica. Antigen assays are more specific, but many cases are missed unless tested by molecular methods. Although polymerase chain reaction (PCR) is effective, the need for sophisticated, expensive equipment, infrastructure, and trained personnel limits its usefulness, especially in the resource-limited, endemic areas. Here, we report development of a recombinase polymerase amplification (RPA) method to detect E. histolytica specifically. Using visual detection by lateral flow (LF), the test was highly sensitive and specific and could be performed without additional equipment. The availability of this inexpensive, sensitive, and field-applicable diagnostic test could facilitate rapid diagnosis and treatment of amebiasis in endemic regions. © The American Society of Tropical Medicine and Hygiene.

  8. Increasing Electrochemiluminescence Intensity of a Wireless Electrode Array Chip by Thousands of Times Using a Diode for Sensitive Visual Detection by a Digital Camera.

    PubMed

    Qi, Liming; Xia, Yong; Qi, Wenjing; Gao, Wenyue; Wu, Fengxia; Xu, Guobao

    2016-01-19

    Both a wireless electrochemiluminescence (ECL) electrode microarray chip and the dramatic increase in ECL by embedding a diode in an electromagnetic receiver coil have been first reported. The newly designed device consists of a chip and a transmitter. The chip has an electromagnetic receiver coil, a mini-diode, and a gold electrode array. The mini-diode can rectify alternating current into direct current and thus enhance ECL intensities by 18 thousand times, enabling a sensitive visual detection using common cameras or smart phones as low cost detectors. The detection limit of hydrogen peroxide using a digital camera is comparable to that using photomultiplier tube (PMT)-based detectors. Coupled with a PMT-based detector, the device can detect luminol with higher sensitivity with linear ranges from 10 nM to 1 mM. Because of the advantages including high sensitivity, high throughput, low cost, high portability, and simplicity, it is promising in point of care testing, drug screening, and high throughput analysis.

  9. Photoinitiator Nucleotide for Quantifying Nucleic Acid Hybridization

    PubMed Central

    Johnson, Leah M.; Hansen, Ryan R.; Urban, Milan; Kuchta, Robert D.; Bowman, Christopher N.

    2010-01-01

    This first report of a photoinitiator-nucleotide conjugate demonstrates a novel approach for sensitive, rapid and visual detection of DNA hybridization events. This approach holds potential for various DNA labeling schemes and for applications benefiting from selective DNA-based polymerization initiators. Here, we demonstrate covalent, enzymatic incorporation of an eosin-photoinitiator 2′-deoxyuridine-5′-triphosphate (EITC-dUTP) conjugate into surface-immobilized DNA hybrids. Subsequent radical chain photoinitiation from these sites using an acrylamide/bis-acrylamide formulation yields a dynamic detection range between 500pM and 50nM of DNA target. Increasing EITC-nucleotide surface densities leads to an increase in surface-based polymer film heights until achieving a film height plateau of 280nm ±20nm at 610 ±70 EITC-nucleotides/μm2. Film heights of 10–20 nm were obtained from eosin surface densities of approximately 20 EITC-nucleotides/μm2 while below the detection limit of ~10 EITC-nucleotides/μm2, no detectable films were formed. This unique threshold behavior is utilized for instrument-free, visual quantification of target DNA concentration ranges. PMID:20337438

  10. Visual search in complex displays: factors affecting conflict detection by air traffic controllers.

    PubMed

    Remington, R W; Johnston, J C; Ruthruff, E; Gold, M; Romera, M

    2000-01-01

    Recent free flight proposals to relax airspace constraints and give greater autonomy to aircraft have raised concerns about their impact on controller performance. Relaxing route and altitude restrictions would reduce the regularity of traffic through individual sectors, possibly impairing controller situation awareness. We examined the impact of this reduced regularity in four visual search experiments that tested controllers' detection of traffic conflicts in the four conditions created by factorial manipulation of fixed routes (present vs. absent) and altitude restrictions (present vs. absent). These four conditions were tested under varying levels of traffic load and conflict geometry (conflict time and conflict angle). Traffic load and conflict geometry showed strong and consistent effects in all experiments. Color coding altitude also substantially improved detection times. In contrast, removing altitude restrictions had only a small negative impact, and removing route restrictions had virtually no negative impact. In some cases conflict detection was actually better without fixed routes. The implications and limitations of these results for the feasibility of free flight are discussed. Actual or potential applications include providing guidance in the selection of free flight operational concepts.

  11. Visual detection of Brucella in bovine biological samples using DNA-activated gold nanoparticles

    PubMed Central

    Kumar, Satish; Kaur, Gurpreet; Ali, Syed Atif; Shrivastava, Sameer; Gupta, Praveen K.; Cooper, Jonathan M.; Chaudhuri, Pallab

    2017-01-01

    Brucellosis is a bacterial disease, which, although affecting cattle primarily, has been associated with human infections, making its detection an important challenge. The existing gold standard diagnosis relies on the culture of bacteria which is a lengthy and costly process, taking up to 45 days. New technologies based on molecular diagnosis have been proposed, either through dip-stick, immunological assays, which have limited specificity, or using nucleic acid tests, which enable to identify the pathogen, but are impractical for use in the field, where most of the reservoir cases are located. Here we demonstrate a new test based on hybridization assays with metal nanoparticles, which, upon detection of a specific pathogen-derived DNA sequence, yield a visual colour change. We characterise the components used in the assay with a range of analytical techniques and show sensitivities down to 1000 cfu/ml for the detection of Brucella. Finally, we demonstrate that the assay works in a range of bovine samples including semen, milk and urine, opening up the potential for its use in the field, in low-resource settings. PMID:28719613

  12. Identification and detection of simple 3D objects with severely blurred vision.

    PubMed

    Kallie, Christopher S; Legge, Gordon E; Yu, Deyue

    2012-12-05

    Detecting and recognizing three-dimensional (3D) objects is an important component of the visual accessibility of public spaces for people with impaired vision. The present study investigated the impact of environmental factors and object properties on the recognition of objects by subjects who viewed physical objects with severely reduced acuity. The experiment was conducted in an indoor testing space. We examined detection and identification of simple convex objects by normally sighted subjects wearing diffusing goggles that reduced effective acuity to 20/900. We used psychophysical methods to examine the effect on performance of important environmental variables: viewing distance (from 10-24 feet, or 3.05-7.32 m) and illumination (overhead fluorescent and artificial window), and object variables: shape (boxes and cylinders), size (heights from 2-6 feet, or 0.61-1.83 m), and color (gray and white). Object identification was significantly affected by distance, color, height, and shape, as well as interactions between illumination, color, and shape. A stepwise regression analysis showed that 64% of the variability in identification could be explained by object contrast values (58%) and object visual angle (6%). When acuity is severely limited, illumination, distance, color, height, and shape influence the identification and detection of simple 3D objects. These effects can be explained in large part by the impact of these variables on object contrast and visual angle. Basic design principles for improving object visibility are discussed.

  13. Maintaining perceptual constancy while remaining vigilant: left hemisphere change blindness and right hemisphere vigilance.

    PubMed

    Vos, Leia; Whitman, Douglas

    2014-01-01

    A considerable literature suggests that the right hemisphere is dominant in vigilance for novel and survival-related stimuli, such as predators, across a wide range of species. In contrast to vigilance for change, change blindness is a failure to detect obvious changes in a visual scene when they are obscured by a disruption in scene presentation. We studied lateralised change detection using a series of scenes with salient changes in either the left or right visual fields. In Study 1 left visual field changes were detected more rapidly than right visual field changes, confirming a right hemisphere advantage for change detection. Increasing stimulus difficulty resulted in greater right visual field detections and left hemisphere detection was more likely when change occurred in the right visual field on a prior trial. In Study 2 an intervening distractor task disrupted the influence of prior trials. Again, faster detection speeds were observed for the left visual field changes with a shift to a right visual field advantage with increasing time-to-detection. This suggests that a right hemisphere role for vigilance, or catching attention, and a left hemisphere role for target evaluation, or maintaining attention, is present at the earliest stage of change detection.

  14. Observer performance in semi-automated microbleed detection

    NASA Astrophysics Data System (ADS)

    Kuijf, Hugo J.; Brundel, Manon; de Bresser, Jeroen; Viergever, Max A.; Biessels, Geert Jan; Geerlings, Mirjam I.; Vincken, Koen L.

    2013-03-01

    Cerebral microbleeds are small bleedings in the human brain, detectable with MRI. Microbleeds are associated with vascular disease and dementia. The number of studies involving microbleed detection is increasing rapidly. Visual rating is the current standard for detection, but is a time-consuming process, especially at high-resolution 7.0 T MR images, has limited reproducibility and is highly observer dependent. Recently, multiple techniques have been published for the semi-automated detection of microbleeds, attempting to overcome these problems. In the present study, a 7.0 T dual-echo gradient echo MR image was acquired in 18 participants with microbleeds from the SMART study. Two experienced observers identified 54 microbleeds in these participants, using a validated visual rating scale. The radial symmetry transform (RST) can be used for semi-automated detection of microbleeds in 7.0 T MR images. In the present study, the results of the RST were assessed by two observers and 47 microbleeds were identified: 35 true positives and 12 extra positives (microbleeds that were missed during visual rating). Hence, after scoring a total number of 66 microbleeds could be identified in the 18 participants. The use of the RST increased the average sensitivity of observers from 59% to 69%. More importantly, inter-observer agreement (ICC and Dice's coefficient) increased from 0.85 and 0.64 to 0.98 and 0.96, respectively. Furthermore, the required rating time was reduced from 30 to 2 minutes per participant. By fine-tuning the RST, sensitivities up to 90% can be achieved, at the cost of extra false positives.

  15. Individual differences in rate of encoding predict estimates of visual short-term memory capacity (K).

    PubMed

    Jannati, Ali; McDonald, John J; Di Lollo, Vincent

    2015-06-01

    The capacity of visual short-term memory (VSTM) is commonly estimated by K scores obtained with a change-detection task. Contrary to common belief, K may be influenced not only by capacity but also by the rate at which stimuli are encoded into VSTM. Experiment 1 showed that, contrary to earlier conclusions, estimates of VSTM capacity obtained with a change-detection task are constrained by temporal limitations. In Experiment 2, we used change-detection and backward-masking tasks to obtain separate within-subject estimates of K and of rate of encoding, respectively. A median split based on rate of encoding revealed significantly higher K estimates for fast encoders. Moreover, a significant correlation was found between K and the estimated rate of encoding. The present findings raise the prospect that the reported relationships between K and such cognitive concepts as fluid intelligence may be mediated not only by VSTM capacity but also by rate of encoding. (c) 2015 APA, all rights reserved).

  16. Crosswalk navigation for people with visual impairments on a wearable device

    NASA Astrophysics Data System (ADS)

    Cheng, Ruiqi; Wang, Kaiwei; Yang, Kailun; Long, Ningbo; Hu, Weijian; Chen, Hao; Bai, Jian; Liu, Dong

    2017-09-01

    Detecting and reminding of crosswalks at urban intersections is one of the most important demands for people with visual impairments. A real-time crosswalk detection algorithm, adaptive extraction and consistency analysis (AECA), is proposed. Compared with existing algorithms, which detect crosswalks in ideal scenarios, the AECA algorithm performs better in challenging scenarios, such as crosswalks at far distances, low-contrast crosswalks, pedestrian occlusion, various illuminances, and the limited resources of portable PCs. Bright stripes of crosswalks are extracted by adaptive thresholding, and are gathered to form crosswalks by consistency analysis. On the testing dataset, the proposed algorithm achieves a precision of 84.6% and a recall of 60.1%, which are higher than the bipolarity-based algorithm. The position and orientation of crosswalks are conveyed to users by voice prompts so as to align themselves with crosswalks and walk along crosswalks. The field tests carried out in various practical scenarios prove the effectiveness and reliability of the proposed navigation approach.

  17. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification.

    PubMed

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64 °C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 10(3) cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 10(3) cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness.

  18. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification

    PubMed Central

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64°C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 103 cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 103 cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness. PMID:26208001

  19. kpLogo: positional k-mer analysis reveals hidden specificity in biological sequences

    PubMed Central

    2017-01-01

    Abstract Motifs of only 1–4 letters can play important roles when present at key locations within macromolecules. Because existing motif-discovery tools typically miss these position-specific short motifs, we developed kpLogo, a probability-based logo tool for integrated detection and visualization of position-specific ultra-short motifs from a set of aligned sequences. kpLogo also overcomes the limitations of conventional motif-visualization tools in handling positional interdependencies and utilizing ranked or weighted sequences increasingly available from high-throughput assays. kpLogo can be found at http://kplogo.wi.mit.edu/. PMID:28460012

  20. Visual Costs of the Inhomogeneity of Luminance and Contrast by Viewing LCD-TFT Screens Off-Axis.

    PubMed

    Ziefle, Martina; Groeger, Thomas; Sommer, Dietmar

    2003-01-01

    In this study the anisotropic characteristics of TFT-LCD (Thin-Film-Transistor-Liquid Crystal Display) screens were examined. Anisotropy occurs as the distribution of luminance and contrast changes over the screen surface due to different viewing angles. On the basis of detailed photometric measurements the detection performance in a visual reaction task was measured in different viewing conditions. Viewing angle (0 degrees, frontal view; 30 degrees, off-axis; 50 degrees, off-axis) as well as ambient lighting (a dark or illuminated room) were varied. Reaction times and accuracy of detection performance were recorded. Results showed TFT's anisotropy to be a crucial factor deteriorating performance. With an increasing viewing angle performance decreased. It is concluded that TFT's anisotropy is a limiting factor for overall suitability and usefulness of this new display technology.

  1. Detection of Bar Transgenic Sugarcane with a Rapid and Visual Loop-Mediated Isothermal Amplification Assay.

    PubMed

    Zhou, Dinggang; Wang, Chunfeng; Li, Zhu; Chen, Yun; Gao, Shiwu; Guo, Jinlong; Lu, Wenying; Su, Yachun; Xu, Liping; Que, Youxiong

    2016-01-01

    Genetic engineering offers an attractive alternative in sugarcane breeding for increasing cane and sugar yields as well as disease and insect resistance. Bar transgenic sugarcane employing the herbicide tolerance is a useful agronomical trait in weed control. In this study, a loop-mediated isothermal amplification (LAMP) assay for rapid detection of the bar gene in transgenic sugarcane has been developed and evaluated. A set of six primers was designed for LAMP-based amplification of the bar gene. The LAMP reaction conditions were optimized as follows: 5.25 mM of Mg(2+), 6:1 ratio of inner vs. outer primer, and 6.0 U of Bst DNA polymerase in a reaction volume of 25.0 μL. The detection limit of the recombinant plasmid 1Ac0229 was as low as 10 copies in the developed LAMP, which was 10-fold higher sensitive than that of conventional PCR. In 100 putative transgenic lines, the bar gene was detected in 100/100 cases (100%) by LAMP and 97/100 cases (97%) by conventional PCR, respectively. In conclusion, the developed LAMP assay is visual, rapid, sensitive, reliable, and cost-effective for detection of the bar specific transgenic sugarcane.

  2. A visual assay and spectrophotometric determination of LLM-105 explosive using detection of gold nanoparticle aggregation at two pH values.

    PubMed

    He, Yi; Cheng, Yang

    2016-08-01

    We report a simple, rapid, and sensitive assay for visual and spectrophotometric detection of the 2,6-diamino-3,5-dinitropyrazine-1-oxide (LLM-105) explosive. The assay is based on different interactions between LLM-105 and gold nanoparticle (AuNP) dispersions at two pH values, leading to the formation of dispersed or aggregated AuNPs. Two AuNP dispersions at two pH values were applied to recognize and detect LLM-105 instead of traditional AuNP dispersion under an aptotic pH to improve the anti-interference ability. The developed assay showed excellent sensitivity with a detection limit of 3 ng/mL, and the presence of as low as 0.2 μg/mL LLM-105 can be directly detected with the bare eye. This sensitivity is about six orders of magnitude higher than that of the reported traditional assays. Additionally, the assay exhibited good selectivity toward LLM-105 over other explosives, sulfur-containing compounds, and amines. Graphical abstract A simple, sensitive, and selective assay for LLM-105 was developed based on the pH-dependent interaction between the LLM-105 explosive and gold nanoparticle dispersion.

  3. Detection of Bar Transgenic Sugarcane with a Rapid and Visual Loop-Mediated Isothermal Amplification Assay

    PubMed Central

    Zhou, Dinggang; Wang, Chunfeng; Li, Zhu; Chen, Yun; Gao, Shiwu; Guo, Jinlong; Lu, Wenying; Su, Yachun; Xu, Liping; Que, Youxiong

    2016-01-01

    Genetic engineering offers an attractive alternative in sugarcane breeding for increasing cane and sugar yields as well as disease and insect resistance. Bar transgenic sugarcane employing the herbicide tolerance is a useful agronomical trait in weed control. In this study, a loop-mediated isothermal amplification (LAMP) assay for rapid detection of the bar gene in transgenic sugarcane has been developed and evaluated. A set of six primers was designed for LAMP-based amplification of the bar gene. The LAMP reaction conditions were optimized as follows: 5.25 mM of Mg2+, 6:1 ratio of inner vs. outer primer, and 6.0 U of Bst DNA polymerase in a reaction volume of 25.0 μL. The detection limit of the recombinant plasmid 1Ac0229 was as low as 10 copies in the developed LAMP, which was 10-fold higher sensitive than that of conventional PCR. In 100 putative transgenic lines, the bar gene was detected in 100/100 cases (100%) by LAMP and 97/100 cases (97%) by conventional PCR, respectively. In conclusion, the developed LAMP assay is visual, rapid, sensitive, reliable, and cost-effective for detection of the bar specific transgenic sugarcane. PMID:27014303

  4. Using spectral-domain optical coherence tomography to detect optic neuropathy in patients with craniosynostosis.

    PubMed

    Dagi, Linda R; Tiedemann, Laura M; Heidary, Gena; Robson, Caroline D; Hall, Amber M; Zurakowski, David

    2014-12-01

    Detecting and monitoring optic neuropathy in patients with craniosynostosis is a clinical challenge due to limited cooperation, and subjective measures of visual function. The purpose of this study was to appraise the correlation of peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral-domain ocular coherence tomography (SD-OCT) with indication of optic neuropathy based on fundus examination. The medical records of all patients with craniosynostosis presenting for ophthalmic evaluation during 2013 were retrospectively reviewed. The following data were abstracted from the record: diagnosis, historical evidence of elevated intracranial pressure, current ophthalmic evaluation and visual field results, and current peripapillary RNFL thickness. A total of 54 patients were included (mean age, 10.6 years [range, 2.4-33.8 years]). Thirteen (24%) had evidence of optic neuropathy based on current fundus examination. Of these, 10 (77%) demonstrated either peripapillary RNFL elevation and papilledema or depression with optic atrophy. Sensitivity for detecting optic atrophy was 88%; for papilledema, 60%; and for either form of optic neuropathy, 77%. Specificity was 94%, 90%, and 83%, respectively. Kappa agreement was substantial for optic atrophy (κ = 0.73) and moderate for papilledema (κ = 0.39) and for either form of optic neuropathy (κ = 0.54). Logistic regression indicated that peripapillary RNFL thickness was predictive of optic neuropathy (P < 0.001). Multivariable analysis demonstrated that RNFL thickness measurements were more sensitive at detecting optic neuropathy than visual field testing (likelihood ratio = 10.02; P = 0.002). Sensitivity and specificity of logMAR visual acuity in detecting optic neuropathy were 15% and 95%, respectively. Peripapillary RNFL thickness measured by SD-OCT provides adjunctive evidence for identifying optic neuropathy in patients with craniosynostosis and appears more sensitive at detecting optic atrophy than papilledema. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  5. In-flight flow visualization characteristics of the NASA F-18 high alpha research vehicle at high angles of attack

    NASA Technical Reports Server (NTRS)

    Fisher, David F.; Delfrate, John H.; Richwine, David M.

    1991-01-01

    Surface and off-surface flow visualization techniques were used to visualize the 3-D separated flows on the NASA F-18 high alpha research vehicle at high angles of attack. Results near the alpha = 25 to 26 deg and alpha = 45 to 49 deg are presented. Both the forebody and leading edge extension (LEX) vortex cores and breakdown locations were visualized using smoke. Forebody and LEX vortex separation lines on the surface were defined using an emitted fluid technique. A laminar separation bubble was also detected on the nose cone using the emitted fluid technique and was similar to that observed in the wind tunnel test, but not as extensive. Regions of attached, separated, and vortical flow were noted on the wing and the leading edge flap using tufts and flow cones, and compared well with limited wind tunnel results.

  6. Cognitive Control Network Contributions to Memory-Guided Visual Attention

    PubMed Central

    Rosen, Maya L.; Stern, Chantal E.; Michalka, Samantha W.; Devaney, Kathryn J.; Somers, David C.

    2016-01-01

    Visual attentional capacity is severely limited, but humans excel in familiar visual contexts, in part because long-term memories guide efficient deployment of attention. To investigate the neural substrates that support memory-guided visual attention, we performed a set of functional MRI experiments that contrast long-term, memory-guided visuospatial attention with stimulus-guided visuospatial attention in a change detection task. Whereas the dorsal attention network was activated for both forms of attention, the cognitive control network (CCN) was preferentially activated during memory-guided attention. Three posterior nodes in the CCN, posterior precuneus, posterior callosal sulcus/mid-cingulate, and lateral intraparietal sulcus exhibited the greatest specificity for memory-guided attention. These 3 regions exhibit functional connectivity at rest, and we propose that they form a subnetwork within the broader CCN. Based on the task activation patterns, we conclude that the nodes of this subnetwork are preferentially recruited for long-term memory guidance of visuospatial attention. PMID:25750253

  7. Accurate metacognition for visual sensory memory representations.

    PubMed

    Vandenbroucke, Annelinde R E; Sligte, Ilja G; Barrett, Adam B; Seth, Anil K; Fahrenfort, Johannes J; Lamme, Victor A F

    2014-04-01

    The capacity to attend to multiple objects in the visual field is limited. However, introspectively, people feel that they see the whole visual world at once. Some scholars suggest that this introspective feeling is based on short-lived sensory memory representations, whereas others argue that the feeling of seeing more than can be attended to is illusory. Here, we investigated this phenomenon by combining objective memory performance with subjective confidence ratings during a change-detection task. This allowed us to compute a measure of metacognition--the degree of knowledge that subjects have about the correctness of their decisions--for different stages of memory. We show that subjects store more objects in sensory memory than they can attend to but, at the same time, have similar metacognition for sensory memory and working memory representations. This suggests that these subjective impressions are not an illusion but accurate reflections of the richness of visual perception.

  8. Adaptive optics without altering visual perception.

    PubMed

    Koenig, D E; Hart, N W; Hofer, H J

    2014-04-01

    Adaptive optics combined with visual psychophysics creates the potential to study the relationship between visual function and the retina at the cellular scale. This potential is hampered, however, by visual interference from the wavefront-sensing beacon used during correction. For example, we have previously shown that even a dim, visible beacon can alter stimulus perception (Hofer et al., 2012). Here we describe a simple strategy employing a longer wavelength (980nm) beacon that, in conjunction with appropriate restriction on timing and placement, allowed us to perform psychophysics when dark adapted without altering visual perception. The method was verified by comparing detection and color appearance of foveally presented small spot stimuli with and without the wavefront beacon present in 5 subjects. As an important caution, we found that significant perceptual interference can occur even with a subliminal beacon when additional measures are not taken to limit exposure. Consequently, the lack of perceptual interference should be verified for a given system, and not assumed based on invisibility of the beacon. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Measuring the effect of attention on simple visual search.

    PubMed

    Palmer, J; Ames, C T; Lindsey, D T

    1993-02-01

    Set-size in visual search may be due to 1 or more of 3 factors: sensory processes such as lateral masking between stimuli, attentional processes limiting the perception of individual stimuli, or attentional processes affecting the decision rules for combining information from multiple stimuli. These possibilities were evaluated in tasks such as searching for a longer line among shorter lines. To evaluate sensory contributions, display set-size effects were compared with cuing conditions that held sensory phenomena constant. Similar effects for the display and cue manipulations suggested that sensory processes contributed little under the conditions of this experiment. To evaluate the contribution of decision processes, the set-size effects were modeled with signal detection theory. In these models, a decision effect alone was sufficient to predict the set-size effects without any attentional limitation due to perception.

  10. Iodine-Mediated Etching of Gold Nanorods for Plasmonic ELISA Based on Colorimetric Detection of Alkaline Phosphatase.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Wang, Shasha; Cheng, Fangbin; Chen, Lingxin

    2015-12-23

    Here, we propose a plasmonic enzyme-linked immunosorbent assay (ELISA) based on highly sensitive colorimetric detection of alkaline phosphatase (ALP), which is achieved by iodine-mediated etching of gold nanorods (AuNRs). Once the sandwich-type immunocomplex is formed, the ALP bound on the polystyrene microwells will hydrolyze ascorbic acid 2-phosphate into ascorbic acid. Subsequently, iodate is reduced to iodine, a moderate oxidant, which etches AuNRs from rod to sphere in shape. The shape change of AuNRs leads to a blue-shift of longitudinal localized surface plasmon resonance. As a result, the solution of AuNRs changes from blue to red. Benefiting from the highly sensitive detection of ALP, the proposed plasmonic ELISA has achieved an ultralow detection limit (100 pg/mL) for human immunoglobulin G (IgG). Importantly, the visual detection limit (3.0 ng/mL) allows the rapid differential diagnosis with the naked eye. The further detection of human IgG in fetal bovine serum indicates its applicability to the determination of low abundance protein in complex biological samples.

  11. Texture based segmentation method to detect atherosclerotic plaque from optical tomography images

    NASA Astrophysics Data System (ADS)

    Prakash, Ammu; Hewko, Mark; Sowa, Michael; Sherif, Sherif

    2013-06-01

    Optical coherence tomography (OCT) imaging has been widely employed in assessing cardiovascular disease. Atherosclerosis is one of the major cause cardio vascular diseases. However visual detection of atherosclerotic plaque from OCT images is often limited and further complicated by high frame rates. We developed a texture based segmentation method to automatically detect plaque and non plaque regions from OCT images. To verify our results we compared them to photographs of the vascular tissue with atherosclerotic plaque that we used to generate the OCT images. Our results show a close match with photographs of vascular tissue with atherosclerotic plaque. Our texture based segmentation method for plaque detection could be potentially used in clinical cardiovascular OCT imaging for plaque detection.

  12. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu(2+) in aqueous solution.

    PubMed

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-Li

    2016-03-15

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Investigation of an EMI sensor for detection of large metallic objects in the presence of metallic clutter

    NASA Astrophysics Data System (ADS)

    Black, Christopher; McMichael, Ian; Riggs, Lloyd

    2005-06-01

    Electromagnetic induction (EMI) sensors and magnetometers have successfully detected surface laid, buried, and visually obscured metallic objects. Potential military activities could require detection of these objects at some distance from a moving vehicle in the presence of metallic clutter. Results show that existing EMI sensors have limited range capabilities and suffer from false alarms due to clutter. This paper presents results of an investigation of an EMI sensor designed for detecting large metallic objects on a moving platform in a high clutter environment. The sensor was developed by the U.S. Army RDECOM CERDEC NVESD in conjunction with the Johns Hopkins University Applied Physics Laboratory.

  14. Visual search and emotion: how children with autism spectrum disorders scan emotional scenes.

    PubMed

    Maccari, Lisa; Pasini, Augusto; Caroli, Emanuela; Rosa, Caterina; Marotta, Andrea; Martella, Diana; Fuentes, Luis J; Casagrande, Maria

    2014-11-01

    This study assessed visual search abilities, tested through the flicker task, in children diagnosed with autism spectrum disorders (ASDs). Twenty-two children diagnosed with ASD and 22 matched typically developing (TD) children were told to detect changes in objects of central interest or objects of marginal interest (MI) embedded in either emotion-laden (positive or negative) or neutral real-world pictures. The results showed that emotion-laden pictures equally interfered with performance of both ASD and TD children, slowing down reaction times compared with neutral pictures. Children with ASD were faster than TD children, particularly in detecting changes in MI objects, the most difficult condition. However, their performance was less accurate than performance of TD children just when the pictures were negative. These findings suggest that children with ASD have better visual search abilities than TD children only when the search is particularly difficult and requires strong serial search strategies. The emotional-social impairment that is usually considered as a typical feature of ASD seems to be limited to processing of negative emotional information.

  15. Non-conscious processing of motion coherence can boost conscious access.

    PubMed

    Kaunitz, Lisandro; Fracasso, Alessio; Lingnau, Angelika; Melcher, David

    2013-01-01

    Research on the scope and limits of non-conscious vision can advance our understanding of the functional and neural underpinnings of visual awareness. Here we investigated whether distributed local features can be bound, outside of awareness, into coherent patterns. We used continuous flash suppression (CFS) to create interocular suppression, and thus lack of awareness, for a moving dot stimulus that varied in terms of coherence with an overall pattern (radial flow). Our results demonstrate that for radial motion, coherence favors the detection of patterns of moving dots even under interocular suppression. Coherence caused dots to break through the masks more often: this indicates that the visual system was able to integrate low-level motion signals into a coherent pattern outside of visual awareness. In contrast, in an experiment using meaningful or scrambled biological motion we did not observe any increase in the sensitivity of detection for meaningful patterns. Overall, our results are in agreement with previous studies on face processing and with the hypothesis that certain features are spatiotemporally bound into coherent patterns even outside of attention or awareness.

  16. Rapid and sensitive detection of early esophageal squamous cell carcinoma with fluorescence probe targeting dipeptidylpeptidase IV

    PubMed Central

    Onoyama, Haruna; Kamiya, Mako; Kuriki, Yugo; Komatsu, Toru; Abe, Hiroyuki; Tsuji, Yosuke; Yagi, Koichi; Yamagata, Yukinori; Aikou, Susumu; Nishida, Masato; Mori, Kazuhiko; Yamashita, Hiroharu; Fujishiro, Mitsuhiro; Nomura, Sachiyo; Shimizu, Nobuyuki; Fukayama, Masashi; Koike, Kazuhiko; Urano, Yasuteru; Seto, Yasuyuki

    2016-01-01

    Early detection of esophageal squamous cell carcinoma (ESCC) is an important prognosticator, but is difficult to achieve by conventional endoscopy. Conventional lugol chromoendoscopy and equipment-based image-enhanced endoscopy, such as narrow-band imaging (NBI), have various practical limitations. Since fluorescence-based visualization is considered a promising approach, we aimed to develop an activatable fluorescence probe to visualize ESCCs. First, based on the fact that various aminopeptidase activities are elevated in cancer, we screened freshly resected specimens from patients with a series of aminopeptidase-activatable fluorescence probes. The results indicated that dipeptidylpeptidase IV (DPP-IV) is specifically activated in ESCCs, and would be a suitable molecular target for detection of esophageal cancer. Therefore, we designed, synthesized and characterized a series of DPP-IV-activatable fluorescence probes. When the selected probe was topically sprayed onto endoscopic submucosal dissection (ESD) or surgical specimens, tumors were visualized within 5 min, and when the probe was sprayed on biopsy samples, the sensitivity, specificity and accuracy reached 96.9%, 85.7% and 90.5%. We believe that DPP-IV-targeted activatable fluorescence probes are practically translatable as convenient tools for clinical application to enable rapid and accurate diagnosis of early esophageal cancer during endoscopic or surgical procedures. PMID:27245876

  17. Expanding the Detection of Traversable Area with RealSense for the Visually Impaired

    PubMed Central

    Yang, Kailun; Wang, Kaiwei; Hu, Weijian; Bai, Jian

    2016-01-01

    The introduction of RGB-Depth (RGB-D) sensors into the visually impaired people (VIP)-assisting area has stirred great interest of many researchers. However, the detection range of RGB-D sensors is limited by narrow depth field angle and sparse depth map in the distance, which hampers broader and longer traversability awareness. This paper proposes an effective approach to expand the detection of traversable area based on a RGB-D sensor, the Intel RealSense R200, which is compatible with both indoor and outdoor environments. The depth image of RealSense is enhanced with IR image large-scale matching and RGB image-guided filtering. Traversable area is obtained with RANdom SAmple Consensus (RANSAC) segmentation and surface normal vector estimation, preliminarily. A seeded growing region algorithm, combining the depth image and RGB image, enlarges the preliminary traversable area greatly. This is critical not only for avoiding close obstacles, but also for allowing superior path planning on navigation. The proposed approach has been tested on a score of indoor and outdoor scenarios. Moreover, the approach has been integrated into an assistance system, which consists of a wearable prototype and an audio interface. Furthermore, the presented approach has been proved to be useful and reliable by a field test with eight visually impaired volunteers. PMID:27879634

  18. Constituting fully integrated visual analysis system for Cu(II) on TiO₂/cellulose paper.

    PubMed

    Li, Shun-Xing; Lin, Xiaofeng; Zheng, Feng-Ying; Liang, Wenjie; Zhong, Yanxue; Cai, Jiabai

    2014-07-15

    As a cheap and abundant porous material, cellulose filter paper was used to immobilize nano-TiO2 and denoted as TiO2/cellulose paper (TCP). With high adsorption capacity for Cu(II) (more than 1.65 mg), TCP was used as an adsorbent, photocatalyst, and colorimetric sensor at the same time. Under the optimum adsorption conditions, i.e., pH 6.5 and 25 °C, the adsorption ratio of Cu(II) was higher than 96.1%. Humic substances from the matrix could be enriched onto TCP but the interference of their colors on colorimetric detection could be eliminated by the photodegradation. In the presence of hydroxylamine, neocuproine, as a selective indicator, was added onto TCP, and a visual color change from white to orange was generated. The concentration of Cu(II) was quantified by the color intensity images using image processing software. This fully integrated visual analysis system was successfully applied for the detection of Cu(II) in 10.0 L of drinking water and seawater with a preconcentration factor of 10(4). The log-linear calibration curve for Cu(II) was in the range of 0.5-50.0 μg L(-1) with a determination coefficient (R(2)) of 0.985 and its detection limit was 0.073 μg L(-1).

  19. GMO detection in food and feed through screening by visual loop-mediated isothermal amplification assays.

    PubMed

    Wang, Cong; Li, Rong; Quan, Sheng; Shen, Ping; Zhang, Dabing; Shi, Jianxin; Yang, Litao

    2015-06-01

    Isothermal DNA/RNA amplification techniques are the primary methodology for developing on-spot rapid nucleic acid amplification assays, and the loop-mediated isothermal amplification (LAMP) technique has been developed and applied in the detection of foodborne pathogens, plant/animal viruses, and genetically modified (GM) food/feed contents. In this study, one set of LAMP assays targeting on eight frequently used universal elements, marker genes, and exogenous target genes, such as CaMV35S promoter, FMV35S promoter, NOS, bar, cry1Ac, CP4 epsps, pat, and NptII, were developed for visual screening of GM contents in plant-derived food samples with high efficiency and accuracy. For these eight LAMP assays, their specificity was evaluated by testing commercial GM plant events and their limits of detection were also determined, which are 10 haploid genome equivalents (HGE) for FMV35S promoter, cry1Ac, and pat assays, as well as five HGE for CaMV35S promoter, bar, NOS terminator, CP4 epsps, and NptII assays. The screening applicability of these LAMP assays was further validated successfully using practical canola, soybean, and maize samples. The results suggested that the established visual LAMP assays are applicable and cost-effective for GM screening in plant-derived food samples.

  20. Visual test of subparts per billion-level mercuric ion with a gold nanoparticle probe after preconcentration by hollow fiber supported liquid membrane.

    PubMed

    Tan, Zhi-qiang; Liu, Jing-fu

    2010-05-15

    With the combination of the gold nanoparticle (AuNP)-based visual test with hollow fiber supported liquid membrane (HFSLM) extraction, a highly sensitive and selective method was developed for field detection of mercuric ion (Hg(2+)) in environmental waters. Hg(2+) in water samples was extracted through HFSLM and trapped in the aqueous acceptor and then visually detected based on the red-to-blue color change of 3-mercaptopropionic acid-functionalized AuNP (MPA-AuNP) probe. The highest extraction efficiency of Hg(2+) was obtained by using a 600 mL sample (pH 8.0, 2.0% (w/v) NaCl), approximately 35 microL of acceptor (10 mM of 2,6-pyridinedicarboxylic acid, pH 4.0) filled in the lumen of a polypropylene hollow fiber tubing (55 cm in length, 50 microm wall thickness, 280 microm inner diameter), a liquid membrane of 2.0% (w/v) trioctycphosphine oxide in undecane, and a shaking rate of 250 rpm. The chromegenic reaction was conducted by incubating the mixture of MPA-AuNP stock solution (12 microL, 15 nM), Tris-borate buffer solution (18 microL, 0.2 M, pH 9.5), and acceptor (30 microL) at 30 degrees C for 1 h. The detection limit can be adjusted to 0.8 microg/L Hg(2+) (corresponding to an enrichment factor of approximately 1000 in the HFSLM) and 2.0 microg/L Hg(2+) (the U.S. Environmental Protection Agency limit of [Hg(2+)] for drinkable water) by using extraction times of 3 and 1 h, respectively. The proposed method is extremely specific for Hg(2+) with tolerance to at least 1000-fold of other environmentally relevant heavy and transition metal ions and was successfully applied to detect Hg(2+) in a certified reference water sample, as well as real river, lake, and tap water samples.

  1. The Hidden Snake in the Grass: Superior Detection of Snakes in Challenging Attentional Conditions

    PubMed Central

    Soares, Sandra C.; Lindström, Björn; Esteves, Francisco; Öhman, Arne

    2014-01-01

    Snakes have provided a serious threat to primates throughout evolution. Furthermore, bites by venomous snakes still cause significant morbidity and mortality in tropical regions of the world. According to the Snake Detection Theory (SDT Isbell, 2006; 2009), the vital need to detect camouflaged snakes provided strong evolutionary pressure to develop astute perceptual capacity in animals that were potential targets for snake attacks. We performed a series of behavioral tests that assessed snake detection under conditions that may have been critical for survival. We used spiders as the control stimulus because they are also a common object of phobias and rated negatively by the general population, thus commonly lumped together with snakes as “evolutionary fear-relevant”. Across four experiments (N = 205) we demonstrate an advantage in snake detection, which was particularly obvious under visual conditions known to impede detection of a wide array of common stimuli, for example brief stimulus exposures, stimuli presentation in the visual periphery, and stimuli camouflaged in a cluttered environment. Our results demonstrate a striking independence of snake detection from ecological factors that impede the detection of other stimuli, which suggests that, consistent with the SDT, they reflect a specific biological adaptation. Nonetheless, the empirical tests we report are limited to only one aspect of this rich theory, which integrates findings across a wide array of scientific disciplines. PMID:25493937

  2. The Hidden Snake in the Grass: Superior Detection of Snakes in Challenging Attentional Conditions.

    PubMed

    Soares, Sandra C; Lindström, Björn; Esteves, Francisco; Ohman, Arne

    2014-01-01

    Snakes have provided a serious threat to primates throughout evolution. Furthermore, bites by venomous snakes still cause significant morbidity and mortality in tropical regions of the world. According to the Snake Detection Theory (SDT Isbell, 2006; 2009), the vital need to detect camouflaged snakes provided strong evolutionary pressure to develop astute perceptual capacity in animals that were potential targets for snake attacks. We performed a series of behavioral tests that assessed snake detection under conditions that may have been critical for survival. We used spiders as the control stimulus because they are also a common object of phobias and rated negatively by the general population, thus commonly lumped together with snakes as "evolutionary fear-relevant". Across four experiments (N = 205) we demonstrate an advantage in snake detection, which was particularly obvious under visual conditions known to impede detection of a wide array of common stimuli, for example brief stimulus exposures, stimuli presentation in the visual periphery, and stimuli camouflaged in a cluttered environment. Our results demonstrate a striking independence of snake detection from ecological factors that impede the detection of other stimuli, which suggests that, consistent with the SDT, they reflect a specific biological adaptation. Nonetheless, the empirical tests we report are limited to only one aspect of this rich theory, which integrates findings across a wide array of scientific disciplines.

  3. Fluorescence growth of self-polymerized fluorescence polydopamine for ratiometric visual detection of DA.

    PubMed

    Yu, Miao; Lu, Yang; Tan, Zhenjiang

    2017-06-01

    In this work, a novel and facile ratiometric fluorescence probe was prepared for the visual detection of dopamine (DA). In this detection system, red-emission CdTe@SiO 2 (r-QDs@SiO 2 ) was used as steady core of the probe and inverse microemulsion method was applied to synthesize uniform r-QDs@SiO 2 , this step could protect CdTe from contacting with human skin directly. Polydopamine (PDA) acted as response signal to detect DA, a very handy method which just combined polyethyleneimine (PEI) with DA together to synthesize PDA, this way for synthesis of PDA was much time-saving and non-toxic than any other methods. Differently from traditional analysis processes, the products of this experiment were also the analysis substances in final. Under optimum measurement conditions, the dual-emission ratiometric fluorescence probe was used for detections of DA in a concentration ranged from 10μM to 80μM with a detection limit of 0.12μM, with addition of DA the color of the probe changed from red to green watched by naked eyes. In addition, the developed probe was also used for detections of DA in human serum samples successfully. This study provides a simple, time-saving and non-toxic approach for detections of DA without the requirement of complex equipment. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Japanese monkeys (Macaca fuscata) quickly detect snakes but not spiders: Evolutionary origins of fear-relevant animals.

    PubMed

    Kawai, Nobuyuki; Koda, Hiroki

    2016-08-01

    Humans quickly detect the presence of evolutionary threats through visual perception. Many theorists have considered humans to be predisposed to respond to both snakes and spiders as evolutionarily fear-relevant stimuli. Evidence supports that human adults, children, and snake-naive monkeys all detect pictures of snakes among pictures of flowers more quickly than vice versa, but recent neurophysiological and behavioral studies suggest that spiders may, in fact, be processed similarly to nonthreat animals. The evidence of quick detection and rapid fear learning by primates is limited to snakes, and no such evidence exists for spiders, suggesting qualitative differences between fear of snakes and fear of spiders. Here, we show that snake-naive Japanese monkeys detect a single snake picture among 8 nonthreat animal pictures (koala) more quickly than vice versa; however, no such difference in detection was observed between spiders and pleasant animals. These robust differences between snakes and spiders are the most convincing evidence that the primate visual system is predisposed to pay attention to snakes but not spiders. These findings suggest that attentional bias toward snakes has an evolutionary basis but that bias toward spiders is more due to top-down, conceptually driven effects of emotion on attention capture. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Magnetic Lateral Flow Strip for the Detection of Cocaine in Urine by Naked Eyes and Smart Phone Camera.

    PubMed

    Wu, Jing; Dong, Mingling; Zhang, Cheng; Wang, Yu; Xie, Mengxia; Chen, Yiping

    2017-06-05

    Magnetic lateral flow strip (MLFS) based on magnetic bead (MB) and smart phone camera has been developed for quantitative detection of cocaine (CC) in urine samples. CC and CC-bovine serum albumin (CC-BSA) could competitively react with MB-antibody (MB-Ab) of CC on the surface of test line of MLFS. The color of MB-Ab conjugate on the test line relates to the concentration of target in the competition immunoassay format, which can be used as a visual signal. Furthermore, the color density of the MB-Ab conjugate can be transferred into digital signal (gray value) by a smart phone, which can be used as a quantitative signal. The linear detection range for CC is 5-500 ng/mL and the relative standard deviations are under 10%. The visual limit of detection was 5 ng/mL and the whole analysis time was within 10 min. The MLFS has been successfully employed for the detection of CC in urine samples without sample pre-treatment and the result is also agreed to that of enzyme-linked immunosorbent assay (ELISA). With the popularization of smart phone cameras, the MLFS has large potential in the detection of drug residues in virtue of its stability, speediness, and low-cost.

  6. Chromatic information and feature detection in fast visual analysis

    DOE PAGES

    Del Viva, Maria M.; Punzi, Giovanni; Shevell, Steven K.; ...

    2016-08-01

    The visual system is able to recognize a scene based on a sketch made of very simple features. This ability is likely crucial for survival, when fast image recognition is necessary, and it is believed that a primal sketch is extracted very early in the visual processing. Such highly simplified representations can be sufficient for accurate object discrimination, but an open question is the role played by color in this process. Rich color information is available in natural scenes, yet artist's sketches are usually monochromatic; and, black-andwhite movies provide compelling representations of real world scenes. Also, the contrast sensitivity ofmore » color is low at fine spatial scales. We approach the question from the perspective of optimal information processing by a system endowed with limited computational resources. We show that when such limitations are taken into account, the intrinsic statistical properties of natural scenes imply that the most effective strategy is to ignore fine-scale color features and devote most of the bandwidth to gray-scale information. We find confirmation of these information-based predictions from psychophysics measurements of fast-viewing discrimination of natural scenes. As a result, we conclude that the lack of colored features in our visual representation, and our overall low sensitivity to high-frequency color components, are a consequence of an adaptation process, optimizing the size and power consumption of our brain for the visual world we live in.« less

  7. Chromatic information and feature detection in fast visual analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Del Viva, Maria M.; Punzi, Giovanni; Shevell, Steven K.

    The visual system is able to recognize a scene based on a sketch made of very simple features. This ability is likely crucial for survival, when fast image recognition is necessary, and it is believed that a primal sketch is extracted very early in the visual processing. Such highly simplified representations can be sufficient for accurate object discrimination, but an open question is the role played by color in this process. Rich color information is available in natural scenes, yet artist's sketches are usually monochromatic; and, black-andwhite movies provide compelling representations of real world scenes. Also, the contrast sensitivity ofmore » color is low at fine spatial scales. We approach the question from the perspective of optimal information processing by a system endowed with limited computational resources. We show that when such limitations are taken into account, the intrinsic statistical properties of natural scenes imply that the most effective strategy is to ignore fine-scale color features and devote most of the bandwidth to gray-scale information. We find confirmation of these information-based predictions from psychophysics measurements of fast-viewing discrimination of natural scenes. As a result, we conclude that the lack of colored features in our visual representation, and our overall low sensitivity to high-frequency color components, are a consequence of an adaptation process, optimizing the size and power consumption of our brain for the visual world we live in.« less

  8. Influence of age, speed and duration of monotonous driving task in traffic on the driver's useful visual field.

    PubMed

    Rogé, Joceline; Pébayle, Thierry; Lambilliotte, Elina; Spitzenstetter, Florence; Giselbrecht, Danièle; Muzet, Alain

    2004-10-01

    Recent research has shown that the useful visual field deteriorates in simulated car driving when the latter can induce a decrease in the level of activation. The first aim of this study was to verify if the same phenomenon occurs when driving is performed in a simulated road traffic situation. The second aim was to discover if this field also deteriorates as a function of the driver's age and of the vehicle's speed. Nine young drivers (from 22 to 34 years) and nine older drivers (from 46 to 59 years) followed a vehicle in road traffic during two two-hour sessions. The car-following task involved driving at 90 km.h(-1) (speed limit on road in France) in one session and at 130 km.h(-1) (speed limit on motorway in France) in the other session. While following the vehicle, the driver had to detect the changes in colour of a luminous signal located in the central part of his/her visual field and a visual signal that appeared at different eccentricities on the rear lights of the vehicles in the traffic. The analysis of the data indicates that the useful visual field deteriorates with the prolongation of the monotonous simulated driving task, with the driver's age and with the vehicle's speed. The results are discussed in terms of general interference and tunnel vision.

  9. Noticing spiders on the left: Evidence on attentional bias and spider fear in the inattentional blindness paradigm.

    PubMed

    Brailsford, Richard; Catherwood, Di; Tyson, Philip J; Edgar, Graham

    2014-01-01

    Attentional biases in anxiety disorders have been assessed primarily using three types of experiment: the emotional Stroop task, the probe-detection task, and variations of the visual search task. It is proposed that the inattentional blindness procedure has the ability to overcome limitations of these paradigms in regard to identifying the components of attentional bias. Three experiments examined attentional responding to spider images in individuals with low and moderate to high spider fear. The results demonstrate that spider fear causes a bias in the engage component of visual attention and this is specific to stimuli presented in the left visual field (i.e., to the right hemisphere). The implications of the results are discussed and recommendations for future research are made.

  10. The Harvest suite for rapid core-genome alignment and visualization of thousands of intraspecific microbial genomes.

    PubMed

    Treangen, Todd J; Ondov, Brian D; Koren, Sergey; Phillippy, Adam M

    2014-01-01

    Whole-genome sequences are now available for many microbial species and clades, however existing whole-genome alignment methods are limited in their ability to perform sequence comparisons of multiple sequences simultaneously. Here we present the Harvest suite of core-genome alignment and visualization tools for the rapid and simultaneous analysis of thousands of intraspecific microbial strains. Harvest includes Parsnp, a fast core-genome multi-aligner, and Gingr, a dynamic visual platform. Together they provide interactive core-genome alignments, variant calls, recombination detection, and phylogenetic trees. Using simulated and real data we demonstrate that our approach exhibits unrivaled speed while maintaining the accuracy of existing methods. The Harvest suite is open-source and freely available from: http://github.com/marbl/harvest.

  11. Background correction in forensic photography. II. Photography of blood under conditions of non-uniform illumination or variable substrate color--practical aspects and limitations.

    PubMed

    Wagner, John H; Miskelly, Gordon M

    2003-05-01

    The combination of photographs taken at wavelengths at and bracketing the peak of a narrow absorbance band can lead to enhanced visualization of the substance causing the narrow absorbance band. This concept can be used to detect putative bloodstains by division of a linear photographic image taken at or near 415 nm with an image obtained by averaging linear photographs taken at or near 395 and 435 nm. Nonlinear images can also be background corrected by substituting subtraction for the division. This paper details experimental applications and limitations of this technique, including wavelength selection of the illuminant and at the camera. Characterization of a digital camera to be used in such a study is also detailed. Detection limits for blood using the three wavelength correction method under optimum conditions have been determined to be as low as 1 in 900 dilution, although on strongly patterned substrates blood diluted more than twenty-fold is difficult to detect. Use of only the 435 nm photograph to estimate the background in the 415 nm image lead to a twofold improvement in detection limit on unpatterned substrates compared with the three wavelength method with the particular camera and lighting system used, but it gave poorer background correction on patterned substrates.

  12. Detection of Stimulus Displacements Across Saccades is Capacity-Limited and Biased in Favor of the Saccade Target

    PubMed Central

    Irwin, David E.; Robinson, Maria M.

    2015-01-01

    Retinal image displacements caused by saccadic eye movements are generally unnoticed. Recent theories have proposed that perceptual stability across saccades depends on a local evaluation process centered on the saccade target object rather than on remapping and evaluating the positions of all objects in a display. In three experiments, we examined whether objects other than the saccade target also influence perceptual stability by measuring displacement detection thresholds across saccades for saccade targets and a variable number of non-saccade objects. We found that the positions of multiple objects are maintained across saccades, but with variable precision, with the saccade target object having priority in the perception of displacement, most likely because it is the focus of attention before the saccade and resides near the fovea after the saccade. The perception of displacement of objects that are not the saccade target is affected by acuity limitations, attentional limitations, and limitations on memory capacity. Unlike previous studies that have found that a postsaccadic blank improves the detection of displacement direction across saccades, we found that postsaccadic blanking hurt the detection of displacement per se by increasing false alarms. Overall, our results are consistent with the hypothesis that visual working memory underlies the perception of stability across saccades. PMID:26640430

  13. Point-of-care testing for streptomycin based on aptamer recognizing and digital image colorimetry by smartphone.

    PubMed

    Lin, Bixia; Yu, Ying; Cao, Yujuan; Guo, Manli; Zhu, Debin; Dai, Jiaxing; Zheng, Minshi

    2018-02-15

    The rapid detection of antibiotic residual in everyday life is very important for food safety. In order to realize the on-site and visual detection of antibiotic, a POCT method was established by using digital image colorimetry based on smartphone. Streptomycin was taken as the analyte model of antibiotics, streptomycin aptamer preferentially recognized analyte, and the excess aptamer hybridized with the complementary DNA to form the dsDNA. SYBR Green I combined with the dsDNA and then emitted obvious green fluorescence, thus the fluorescence intensity decreased with the increasing of streptomycin concentration. Then a smartphone-based device was constructed as the fluorescence readout. The smartphone camera acquired the images of the fluorescence derived from the samples, and the Touch Color APP installed in smartphone read out the RGB values of the images. There was a linear relationship between the G values and the streptomycin concentrations in the range of 0.1-100µM. The detection limit was 94nM, which was lower than the maximum residue limit defined by World Health Organization. The POCT method was applied for determining streptomycin in chicken and milk samples with recoveries in 94.1-110%. This method had the advantages of good selectivity, simple operation and on-site visualization. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Real-time distortion correction for visual inspection systems based on FPGA

    NASA Astrophysics Data System (ADS)

    Liang, Danhua; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin

    2008-03-01

    Visual inspection is a kind of new technology based on the research of computer vision, which focuses on the measurement of the object's geometry and location. It can be widely used in online measurement, and other real-time measurement process. Because of the defects of the traditional visual inspection, a new visual detection mode -all-digital intelligent acquisition and transmission is presented. The image processing, including filtering, image compression, binarization, edge detection and distortion correction, can be completed in the programmable devices -FPGA. As the wide-field angle lens is adopted in the system, the output images have serious distortion. Limited by the calculating speed of computer, software can only correct the distortion of static images but not the distortion of dynamic images. To reach the real-time need, we design a distortion correction system based on FPGA. The method of hardware distortion correction is that the spatial correction data are calculated first under software circumstance, then converted into the address of hardware storage and stored in the hardware look-up table, through which data can be read out to correct gray level. The major benefit using FPGA is that the same circuit can be used for other circularly symmetric wide-angle lenses without being modified.

  15. Hydrazinylpyridine based highly selective optical sensor for aqueous source of carbonate ions: Electrochemical and DFT studies

    NASA Astrophysics Data System (ADS)

    Thimaradka, Vikram; Pangannaya, Srikala; Mohan, Makesh; Trivedi, Darshak R.

    2018-03-01

    A series of new receptors PDZ1-3 based on 2-(arylidenehydrazinyl)pyridines have been designed and synthesized for the detection of biologically and environmentally important ions. The colorimetric detection of CO32 - using neutral organic receptor PDZ-1 has been achieved with characteristic visual colour change from yellow to green accompanied by a large redshift of 215 nm in absorption maxima. UV-Vis spectroscopic and cyclic voltammetric studies reveal the stoichiometry of binding and electrochemistry of host-guest complex formation. The binding constant was found to be 0.77 × 104 M- 2. In addition, electrochemical studies provide an insight into the stability of the complex. DFT studies performed on the PDZ-1 and PDZ-1 - CO32 - complex reveal the binding mechanism involved in the anion detection process. PDZ-1 is highly selective for carbonate and does not show any colorimetric response towards any other anions or cations, while PDZ-2 and PDZ-3 remain inactive in the ion detection process. The limit of detection (LOD) and limit of quantification (LOQ) of PDZ-1 for carbonate was found to be 0.11 mM and 0.36 mM respectively. Considerable binding constant and limit of detection make PDZ-1 to be used as a real time sensor for the detection of carbonate in environmental and biological samples.

  16. Advanced boundary layer transition measurement methods for flight applications

    NASA Technical Reports Server (NTRS)

    Holmes, B. J.; Croom, C. C.; Gail, P. D.; Manuel, G. S.; Carraway, D. L.

    1986-01-01

    In modern laminar flow flight research, it is important to understand the specific cause(s) of laminar to turbulent boundary-layer transition. Such information is crucial to the exploration of the limits of practical application of laminar flow for drag reduction on aircraft. The transition modes of interest in current flight investigations include the viscous Tollmien-Schlichting instability, the inflectional instability at laminar separation, and the crossflow inflectional instability, as well as others. This paper presents the results to date of research on advanced devices and methods used for the study of laminar boundary-layer transition phenomena in the flight environment. Recent advancements in the development of arrayed hot-film devices and of a new flow visualization method are discussed. Arrayed hot-film devices have been designed to detect the presence of laminar separation, and of crossflow vorticity. The advanced flow visualization method utilizes color changes in liquid-crystal coatings to detect boundary-layer transition at high altitude flight conditions. Flight and wind tunnel data are presented to illustrate the design and operation of these advanced methods. These new research tools provide information on disturbance growth and transition mode which is essential to furthering our understanding of practical design limits for applications of laminar flow technology.

  17. Topographic contribution of early visual cortex to short-term memory consolidation: a transcranial magnetic stimulation study.

    PubMed

    van de Ven, Vincent; Jacobs, Christianne; Sack, Alexander T

    2012-01-04

    The neural correlates for retention of visual information in visual short-term memory are considered separate from those of sensory encoding. However, recent findings suggest that sensory areas may play a role also in short-term memory. We investigated the functional relevance, spatial specificity, and temporal characteristics of human early visual cortex in the consolidation of capacity-limited topographic visual memory using transcranial magnetic stimulation (TMS). Topographically specific TMS pulses were delivered over lateralized occipital cortex at 100, 200, or 400 ms into the retention phase of a modified change detection task with low or high memory loads. For the high but not the low memory load, we found decreased memory performance for memory trials in the visual field contralateral, but not ipsilateral to the side of TMS, when pulses were delivered at 200 ms into the retention interval. A behavioral version of the TMS experiment, in which a distractor stimulus (memory mask) replaced the TMS pulses, further corroborated these findings. Our findings suggest that retinotopic visual cortex contributes to the short-term consolidation of topographic visual memory during early stages of the retention of visual information. Further, TMS-induced interference decreased the strength (amplitude) of the memory representation, which most strongly affected the high memory load trials.

  18. Influence of visual clutter on the effect of navigated safety inspection: a case study on elevator installation.

    PubMed

    Liao, Pin-Chao; Sun, Xinlu; Liu, Mei; Shih, Yu-Nien

    2018-01-11

    Navigated safety inspection based on task-specific checklists can increase the hazard detection rate, theoretically with interference from scene complexity. Visual clutter, a proxy of scene complexity, can theoretically impair visual search performance, but its impact on the effect of safety inspection performance remains to be explored for the optimization of navigated inspection. This research aims to explore whether the relationship between working memory and hazard detection rate is moderated by visual clutter. Based on a perceptive model of hazard detection, we: (a) developed a mathematical influence model for construction hazard detection; (b) designed an experiment to observe the performance of hazard detection rate with adjusted working memory under different levels of visual clutter, while using an eye-tracking device to observe participants' visual search processes; (c) utilized logistic regression to analyze the developed model under various visual clutter. The effect of a strengthened working memory on the detection rate through increased search efficiency is more apparent in high visual clutter. This study confirms the role of visual clutter in construction-navigated inspections, thus serving as a foundation for the optimization of inspection planning.

  19. Visual short-term memory capacity for simple and complex objects.

    PubMed

    Luria, Roy; Sessa, Paola; Gotler, Alex; Jolicoeur, Pierre; Dell'Acqua, Roberto

    2010-03-01

    Does the capacity of visual short-term memory (VSTM) depend on the complexity of the objects represented in memory? Although some previous findings indicated lower capacity for more complex stimuli, other results suggest that complexity effects arise during retrieval (due to errors in the comparison process with what is in memory) that is not related to storage limitations of VSTM, per se. We used ERPs to track neuronal activity specifically related to retention in VSTM by measuring the sustained posterior contralateral negativity during a change detection task (which required detecting if an item was changed between a memory and a test array). The sustained posterior contralateral negativity, during the retention interval, was larger for complex objects than for simple objects, suggesting that neurons mediating VSTM needed to work harder to maintain more complex objects. This, in turn, is consistent with the view that VSTM capacity depends on complexity.

  20. Single α-particle irradiation permits real-time visualization of RNF8 accumulation at DNA damaged sites

    NASA Astrophysics Data System (ADS)

    Muggiolu, Giovanna; Pomorski, Michal; Claverie, Gérard; Berthet, Guillaume; Mer-Calfati, Christine; Saada, Samuel; Devès, Guillaume; Simon, Marina; Seznec, Hervé; Barberet, Philippe

    2017-01-01

    As well as being a significant source of environmental radiation exposure, α-particles are increasingly considered for use in targeted radiation therapy. A better understanding of α-particle induced damage at the DNA scale can be achieved by following their tracks in real-time in targeted living cells. Focused α-particle microbeams can facilitate this but, due to their low energy (up to a few MeV) and limited range, α-particles detection, delivery, and follow-up observations of radiation-induced damage remain difficult. In this study, we developed a thin Boron-doped Nano-Crystalline Diamond membrane that allows reliable single α-particles detection and single cell irradiation with negligible beam scattering. The radiation-induced responses of single 3 MeV α-particles delivered with focused microbeam are visualized in situ over thirty minutes after irradiation by the accumulation of the GFP-tagged RNF8 protein at DNA damaged sites.

  1. Color visual simulation applications at the Defense Mapping Agency

    NASA Astrophysics Data System (ADS)

    Simley, J. D.

    1984-09-01

    The Defense Mapping Agency (DMA) produces the Digital Landmass System data base to provide culture and terrain data in support of numerous aircraft simulators. In order to conduct data base and simulation quality control and requirements analysis, DMA has developed the Sensor Image Simulator which can rapidly generate visual and radar static scene digital simulations. The use of color in visual simulation allows the clear portrayal of both landcover and terrain data, whereas the initial black and white capabilities were restricted in this role and thus found limited use. Color visual simulation has many uses in analysis to help determine the applicability of current and prototype data structures to better meet user requirements. Color visual simulation is also significant in quality control since anomalies can be more easily detected in natural appearing forms of the data. The realism and efficiency possible with advanced processing and display technology, along with accurate data, make color visual simulation a highly effective medium in the presentation of geographic information. As a result, digital visual simulation is finding increased potential as a special purpose cartographic product. These applications are discussed and related simulation examples are presented.

  2. A visual model for object detection based on active contours and level-set method.

    PubMed

    Satoh, Shunji

    2006-09-01

    A visual model for object detection is proposed. In order to make the detection ability comparable with existing technical methods for object detection, an evolution equation of neurons in the model is derived from the computational principle of active contours. The hierarchical structure of the model emerges naturally from the evolution equation. One drawback involved with initial values of active contours is alleviated by introducing and formulating convexity, which is a visual property. Numerical experiments show that the proposed model detects objects with complex topologies and that it is tolerant of noise. A visual attention model is introduced into the proposed model. Other simulations show that the visual properties of the model are consistent with the results of psychological experiments that disclose the relation between figure-ground reversal and visual attention. We also demonstrate that the model tends to perceive smaller regions as figures, which is a characteristic observed in human visual perception.

  3. Color-Change Detection Activity in the Primate Superior Colliculus.

    PubMed

    Herman, James P; Krauzlis, Richard J

    2017-01-01

    The primate superior colliculus (SC) is a midbrain structure that participates in the control of spatial attention. Previous studies examining the role of the SC in attention have mostly used luminance-based visual features (e.g., motion, contrast) as the stimuli and saccadic eye movements as the behavioral response, both of which are known to modulate the activity of SC neurons. To explore the limits of the SC's involvement in the control of spatial attention, we recorded SC neuronal activity during a task using color, a visual feature dimension not traditionally associated with the SC, and required monkeys to detect threshold-level changes in the saturation of a cued stimulus by releasing a joystick during maintained fixation. Using this color-based spatial attention task, we found substantial cue-related modulation in all categories of visually responsive neurons in the intermediate layers of the SC. Notably, near-threshold changes in color saturation, both increases and decreases, evoked phasic bursts of activity with magnitudes as large as those evoked by stimulus onset. This change-detection activity had two distinctive features: activity for hits was larger than for misses, and the timing of change-detection activity accounted for 67% of joystick release latency, even though it preceded the release by at least 200 ms. We conclude that during attention tasks, SC activity denotes the behavioral relevance of the stimulus regardless of feature dimension and that phasic event-related SC activity is suitable to guide the selection of manual responses as well as saccadic eye movements.

  4. Time-gated luminescence microscopy allowing direct visual inspection of lanthanide-stained microorganisms in background-free condition.

    PubMed

    Jin, Dayong; Piper, James A

    2011-03-15

    Application of standard immuno-fluorescence microscopy techniques for detection of rare-event microorganisms in dirty samples is severely limited by autofluorescence of nontarget organisms or other debris. Time-gated detection using gateable array detectors in combination with microsecond-lifetime luminescent bioprobes (usually lanthanide-based) is highly effective in suppression of (nanosecond-lifetime) autofluorescence background; however, the complexity and cost of the instrumentation is a major barrier to application of these techniques to routine diagnostics. We report a practical, low-cost implementation of time-gated luminescence detection in a standard epifluorescence microscope which has been modified to include a high-power pulsed UV light-emitting diode (LED) illumination source and a standard fast chopper inserted in the focal plane behind a microscope eyepiece. Synchronization of the pulsed illumination/gated detection cycle is driven from the clock signal from the chopper. To achieve time-gated luminescence intensities sufficient for direct visual observation, we use high cycle rates, up to 2.5 kHz, taking advantage of the fast switching capabilities of the LED source. We have demonstrated real-time direct-visual inspection of europium-labeled Giardia lamblia cysts in dirty samples and Cryptosporidium parvum oocysts in fruit juice concentrate. The signal-to-background ratio has been enhanced by a factor of 18 in time-gated mode. The availability of low-cost, robust time-gated microscopes will aid development of long-lifetime luminescence bioprobes and accelerate their application in routine laboratory diagnostics.

  5. Attending to unrelated targets boosts short-term memory for color arrays.

    PubMed

    Makovski, Tal; Swallow, Khena M; Jiang, Yuhong V

    2011-05-01

    Detecting a target typically impairs performance in a second, unrelated task. It has been recently reported however, that detecting a target in a stream of distractors can enhance long-term memory of faces and scenes that were presented concurrently with the target (the attentional boost effect). In this study we ask whether target detection also enhances performance in a visual short-term memory task, where capacity limits are severe. Participants performed two tasks at once: a one shot, color change detection task and a letter-detection task. In Experiment 1, a central letter appeared at the same time as 3 or 5 color patches (memory display). Participants encoded the colors and pressed the spacebar if the letter was a T (target). After a short retention interval, a probe display of color patches appeared. Performance on the change detection task was enhanced when a target, rather than a distractor, appeared with the memory display. This effect was not modulated by memory load or the frequency of trials in which a target appeared. However, there was no enhancement when the target appeared at the same time as the probe display (Experiment 2a) or during the memory retention interval (Experiment 2b). Together these results suggest that detecting a target facilitates the encoding of unrelated information into visual short-term memory. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Turning behaviour depends on frictional damping in the fruit fly Drosophila.

    PubMed

    Hesselberg, Thomas; Lehmann, Fritz-Olaf

    2007-12-01

    Turning behaviour in the fruit fly Drosophila depends on several factors including not only feedback from sensory organs and muscular control of wing motion, but also the mass moments of inertia and the frictional damping coefficient of the rotating body. In the present study we evaluate the significance of body friction for yaw turning and thus the limits of visually mediated flight control in Drosophila, by scoring tethered flies flying in a flight simulator on their ability to visually compensate a bias on a moving object and a visual background panorama at different simulated frictional dampings. We estimated the fly's natural damping coefficient from a numerical aerodynamic model based on both friction on the body and the flapping wings during saccadic turning. The model predicts a coefficient of 54 x 10(-12) Nm s, which is more than 100-times larger than the value estimated from a previous study on the body alone. Our estimate suggests that friction plays a larger role for yaw turning in Drosophila than moments of inertia. The simulator experiments showed that visual performance of the fruit fly collapses near the physical conditions estimated for freely flying animals, which is consistent with the suggested role of the halteres for flight stabilization. However, kinematic analyses indicate that the measured loss of flight control might be due predominantly to the limited fine control in the fly's steering muscles below a threshold of 1-2 degrees stroke amplitude, rather than resulting from the limits of visual motion detection by the fly's compound eyes. We discuss the impact of these results and suggest that the elevated frictional coefficient permits freely flying fruit flies to passively terminate rotational body movements without producing counter-torque during the second half of the saccadic turning manoeuvre.

  7. Evolution and Optimality of Similar Neural Mechanisms for Perception and Action during Search

    PubMed Central

    Zhang, Sheng; Eckstein, Miguel P.

    2010-01-01

    A prevailing theory proposes that the brain's two visual pathways, the ventral and dorsal, lead to differing visual processing and world representations for conscious perception than those for action. Others have claimed that perception and action share much of their visual processing. But which of these two neural architectures is favored by evolution? Successful visual search is life-critical and here we investigate the evolution and optimality of neural mechanisms mediating perception and eye movement actions for visual search in natural images. We implement an approximation to the ideal Bayesian searcher with two separate processing streams, one controlling the eye movements and the other stream determining the perceptual search decisions. We virtually evolved the neural mechanisms of the searchers' two separate pathways built from linear combinations of primary visual cortex receptive fields (V1) by making the simulated individuals' probability of survival depend on the perceptual accuracy finding targets in cluttered backgrounds. We find that for a variety of targets, backgrounds, and dependence of target detectability on retinal eccentricity, the mechanisms of the searchers' two processing streams converge to similar representations showing that mismatches in the mechanisms for perception and eye movements lead to suboptimal search. Three exceptions which resulted in partial or no convergence were a case of an organism for which the targets are equally detectable across the retina, an organism with sufficient time to foveate all possible target locations, and a strict two-pathway model with no interconnections and differential pre-filtering based on parvocellular and magnocellular lateral geniculate cell properties. Thus, similar neural mechanisms for perception and eye movement actions during search are optimal and should be expected from the effects of natural selection on an organism with limited time to search for food that is not equi-detectable across its retina and interconnected perception and action neural pathways. PMID:20838589

  8. Point-of-care mobile digital microscopy and deep learning for the detection of soil-transmitted helminths and Schistosoma haematobium.

    PubMed

    Holmström, Oscar; Linder, Nina; Ngasala, Billy; Mårtensson, Andreas; Linder, Ewert; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Diwan, Vinod; Lundin, Johan

    2017-06-01

    Microscopy remains the gold standard in the diagnosis of neglected tropical diseases. As resource limited, rural areas often lack laboratory equipment and trained personnel, new diagnostic techniques are needed. Low-cost, point-of-care imaging devices show potential in the diagnosis of these diseases. Novel, digital image analysis algorithms can be utilized to automate sample analysis. Evaluation of the imaging performance of a miniature digital microscopy scanner for the diagnosis of soil-transmitted helminths and Schistosoma haematobium, and training of a deep learning-based image analysis algorithm for automated detection of soil-transmitted helminths in the captured images. A total of 13 iodine-stained stool samples containing Ascaris lumbricoides, Trichuris trichiura and hookworm eggs and 4 urine samples containing Schistosoma haematobium were digitized using a reference whole slide-scanner and the mobile microscopy scanner. Parasites in the images were identified by visual examination and by analysis with a deep learning-based image analysis algorithm in the stool samples. Results were compared between the digital and visual analysis of the images showing helminth eggs. Parasite identification by visual analysis of digital slides captured with the mobile microscope was feasible for all analyzed parasites. Although the spatial resolution of the reference slide-scanner is higher, the resolution of the mobile microscope is sufficient for reliable identification and classification of all parasites studied. Digital image analysis of stool sample images captured with the mobile microscope showed high sensitivity for detection of all helminths studied (range of sensitivity = 83.3-100%) in the test set (n = 217) of manually labeled helminth eggs. In this proof-of-concept study, the imaging performance of a mobile, digital microscope was sufficient for visual detection of soil-transmitted helminths and Schistosoma haematobium. Furthermore, we show that deep learning-based image analysis can be utilized for the automated detection and classification of helminths in the captured images.

  9. Point-of-care mobile digital microscopy and deep learning for the detection of soil-transmitted helminths and Schistosoma haematobium

    PubMed Central

    Holmström, Oscar; Linder, Nina; Ngasala, Billy; Mårtensson, Andreas; Linder, Ewert; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Diwan, Vinod; Lundin, Johan

    2017-01-01

    ABSTRACT Background: Microscopy remains the gold standard in the diagnosis of neglected tropical diseases. As resource limited, rural areas often lack laboratory equipment and trained personnel, new diagnostic techniques are needed. Low-cost, point-of-care imaging devices show potential in the diagnosis of these diseases. Novel, digital image analysis algorithms can be utilized to automate sample analysis. Objective: Evaluation of the imaging performance of a miniature digital microscopy scanner for the diagnosis of soil-transmitted helminths and Schistosoma haematobium, and training of a deep learning-based image analysis algorithm for automated detection of soil-transmitted helminths in the captured images. Methods: A total of 13 iodine-stained stool samples containing Ascaris lumbricoides, Trichuris trichiura and hookworm eggs and 4 urine samples containing Schistosoma haematobium were digitized using a reference whole slide-scanner and the mobile microscopy scanner. Parasites in the images were identified by visual examination and by analysis with a deep learning-based image analysis algorithm in the stool samples. Results were compared between the digital and visual analysis of the images showing helminth eggs. Results: Parasite identification by visual analysis of digital slides captured with the mobile microscope was feasible for all analyzed parasites. Although the spatial resolution of the reference slide-scanner is higher, the resolution of the mobile microscope is sufficient for reliable identification and classification of all parasites studied. Digital image analysis of stool sample images captured with the mobile microscope showed high sensitivity for detection of all helminths studied (range of sensitivity = 83.3–100%) in the test set (n = 217) of manually labeled helminth eggs. Conclusions: In this proof-of-concept study, the imaging performance of a mobile, digital microscope was sufficient for visual detection of soil-transmitted helminths and Schistosoma haematobium. Furthermore, we show that deep learning-based image analysis can be utilized for the automated detection and classification of helminths in the captured images. PMID:28838305

  10. Nestling coloration is adjusted to parent visual performance in altricial birds irrespective of assumptions on vision system for Laniidae and owls, a reply to Renoult et al.

    PubMed

    Avilés, J M; Soler, J J

    2010-01-01

    We have recently published support to the hypothesis that visual systems of parents could affect nestling detectability and, consequently, influences the evolution of nestling colour designs in altricial birds. We provided comparative evidence of an adjustment of nestling colour designs to the visual system of parents that we have found in a comparative study on 22 altricial bird species. In this issue, however, Renoult et al. (J. Evol. Biol., 2009) question some of the assumptions and statistical approaches in our study. Their argumentation relied on two major points: (1) an incorrect assignment of vision system to four out of 22 sampled species in our study; and (2) the use of an incorrect approach for phylogenetic correction of the predicted associations. Here, we discuss in detail re-assignation of vision systems in that study and propose alternative interpretation for current knowledge on spectrophotometric data of avian pigments. We reanalysed the data by using phylogenetic generalized least squares analyses that account for the alluded limitations of phylogenetically independent contrasts and, in accordance with the hypothesis, confirmed a significant influence of parental visual system on gape coloration. Our results proved to be robust to the assumptions on visual system evolution for Laniidae and nocturnal owls that Renoult et al. (J. Evol. Biol., 2009) study suggested may have flawed our early findings. Thus, the hypothesis that selection has resulted in increased detectability of nestling by adjusting gape coloration to parental visual systems is currently supported by our comparative data.

  11. Manipulating the Surface Chemistry of Quantum Dots for Sensitive Ratiometric Fluorescence Detection of Sulfur Dioxide.

    PubMed

    Li, Huihui; Zhu, Houjuan; Sun, Mingtai; Yan, Yehan; Zhang, Kui; Huang, Dejian; Wang, Suhua

    2015-08-11

    Herein, we report a novel approach to the rapid visual detection of gaseous sulfur dioxide (SO2) by manipulating the surface chemistry of 3-aminopropyltriethoxysilane (APTS)-modified quantum dots (QDs) using fluorescent coumarin-3-carboxylic acid (CCA) for specific reaction with SO2. The CCA molecules are attached to the surface amino groups of the QDs through electrostatic attraction, thus the fluorescence of CCA is greatly suppressed because of the formation of an ion-pair complex between the ATPS-modified QDs and CCA. Such an interaction is vulnerable to SO2 because SO2 can readily react with surface amino groups to form strong charge-transfer complexes and subsequently release the strongly fluorescent CCA molecules. The mechanism has been carefully verified through a series of control experiments. Upon exposure to different amounts of SO2, the fluorescent color of the nanoparticle-based sensor displays continuously changes from red to blue. Most importantly, the approach owns high selectivity for SO2 and a tolerance of interference, which enables the sensor to detect SO2 in a practical application. Using this fluorescence-based sensing method, we have achieved a visual detection limit of 6 ppb for gaseous SO2.

  12. A novel fluorescent probe for rapid and sensitive detection of hydrogen sulfide in living cells

    NASA Astrophysics Data System (ADS)

    Pan, Jian; Xu, Junchao; Zhang, Youlai; Wang, Liang; Qin, Caiqin; Zeng, Lintao; Zhang, Yue

    2016-11-01

    A novel fluorescent probe for H2S was developed based on a far-red emitting indole-BODIPY, which was decorated with morpholine and 2,4-dinitrobenzenesulfonyl (DNBS) group. This probe showed rapid response (t1/2 = 3 min), high selectivity and sensitivity for H2S with significant colorimetric and fluorescence OFF-ON signals, which was triggered by cleavage of 2,4-dinitrobenzenesulfonyl group. This probe could quantitatively detect the concentrations of H2S ranging from 0 to 60 μM, and the detection of limit was found to be as low as 26 nM. Cell imaging results indicated that the probe could detect and visualize H2S in the living cells.

  13. Visual detection of driving while intoxicated. Project interim report : identification of visual cues and development of detection methods

    DOT National Transportation Integrated Search

    1979-01-01

    The report describes the initial phase of a two-phase project on the visual, on-the-road detection of driving while intoxicated (DWI). The purpose of the overall project is to develop and test procedures for enhancing on-the-road detection of DWI. Th...

  14. Are There Multiple Visual Short-Term Memory Stores?

    PubMed Central

    Sligte, Ilja G.; Scholte, H. Steven; Lamme, Victor A. F.

    2008-01-01

    Background Classic work on visual short-term memory (VSTM) suggests that people store a limited amount of items for subsequent report. However, when human observers are cued to shift attention to one item in VSTM during retention, it seems as if there is a much larger representation, which keeps additional items in a more fragile VSTM store. Thus far, it is not clear whether the capacity of this fragile VSTM store indeed exceeds the traditional capacity limits of VSTM. The current experiments address this issue and explore the capacity, stability, and duration of fragile VSTM representations. Methodology/Principal Findings We presented cues in a change-detection task either just after off-set of the memory array (iconic-cue), 1,000 ms after off-set of the memory array (retro-cue) or after on-set of the probe array (post-cue). We observed three stages in visual information processing 1) iconic memory with unlimited capacity, 2) a four seconds lasting fragile VSTM store with a capacity that is at least a factor of two higher than 3) the robust and capacity-limited form of VSTM. Iconic memory seemed to depend on the strength of the positive after-image resulting from the memory display and was virtually absent under conditions of isoluminance or when intervening light masks were presented. This suggests that iconic memory is driven by prolonged retinal activation beyond stimulus duration. Fragile VSTM representations were not affected by light masks, but were completely overwritten by irrelevant pattern masks that spatially overlapped the memory array. Conclusions/Significance We find that immediately after a stimulus has disappeared from view, subjects can still access information from iconic memory because they can see an after-image of the display. After that period, human observers can still access a substantial, but somewhat more limited amount of information from a high-capacity, but fragile VSTM that is overwritten when new items are presented to the eyes. What is left after that is the traditional VSTM store, with a limit of about four objects. We conclude that human observers store more sustained representations than is evident from standard change detection tasks and that these representations can be accessed at will. PMID:18301775

  15. Are there multiple visual short-term memory stores?

    PubMed

    Sligte, Ilja G; Scholte, H Steven; Lamme, Victor A F

    2008-02-27

    Classic work on visual short-term memory (VSTM) suggests that people store a limited amount of items for subsequent report. However, when human observers are cued to shift attention to one item in VSTM during retention, it seems as if there is a much larger representation, which keeps additional items in a more fragile VSTM store. Thus far, it is not clear whether the capacity of this fragile VSTM store indeed exceeds the traditional capacity limits of VSTM. The current experiments address this issue and explore the capacity, stability, and duration of fragile VSTM representations. We presented cues in a change-detection task either just after off-set of the memory array (iconic-cue), 1,000 ms after off-set of the memory array (retro-cue) or after on-set of the probe array (post-cue). We observed three stages in visual information processing 1) iconic memory with unlimited capacity, 2) a four seconds lasting fragile VSTM store with a capacity that is at least a factor of two higher than 3) the robust and capacity-limited form of VSTM. Iconic memory seemed to depend on the strength of the positive after-image resulting from the memory display and was virtually absent under conditions of isoluminance or when intervening light masks were presented. This suggests that iconic memory is driven by prolonged retinal activation beyond stimulus duration. Fragile VSTM representations were not affected by light masks, but were completely overwritten by irrelevant pattern masks that spatially overlapped the memory array. We find that immediately after a stimulus has disappeared from view, subjects can still access information from iconic memory because they can see an after-image of the display. After that period, human observers can still access a substantial, but somewhat more limited amount of information from a high-capacity, but fragile VSTM that is overwritten when new items are presented to the eyes. What is left after that is the traditional VSTM store, with a limit of about four objects. We conclude that human observers store more sustained representations than is evident from standard change detection tasks and that these representations can be accessed at will.

  16. Underwater linear polarization: physical limitations to biological functions

    PubMed Central

    Shashar, Nadav; Johnsen, Sönke; Lerner, Amit; Sabbah, Shai; Chiao, Chuan-Chin; Mäthger, Lydia M.; Hanlon, Roger T.

    2011-01-01

    Polarization sensitivity is documented in a range of marine animals. The variety of tasks for which animals can use this sensitivity, and the range over which they do so, are confined by the visual systems of these animals and by the propagation of the polarization information in the aquatic environment. We examine the environmental physical constraints in an attempt to reveal the depth, range and other limitations to the use of polarization sensitivity by marine animals. In clear oceanic waters, navigation that is based on the polarization pattern of the sky appears to be limited to shallow waters, while solar-based navigation is possible down to 200–400 m. When combined with intensity difference, polarization sensitivity allows an increase in target detection range by 70–80% with an upper limit of 15 m for large-eyed animals. This distance will be significantly smaller for small animals, such as plankton, and in turbid waters. Polarization-contrast detection, which is relevant to object detection and communication, is strongly affected by water conditions and in clear waters its range limit may reach 15 m as well. We show that polarization sensitivity may also serve for target distance estimation, when examining point source bioluminescent objects in the photic mesopelagic depth range. PMID:21282168

  17. Research on metallic material defect detection based on bionic sensing of human visual properties

    NASA Astrophysics Data System (ADS)

    Zhang, Pei Jiang; Cheng, Tao

    2018-05-01

    Due to the fact that human visual system can quickly lock the areas of interest in complex natural environment and focus on it, this paper proposes an eye-based visual attention mechanism by simulating human visual imaging features based on human visual attention mechanism Bionic Sensing Visual Inspection Model Method to Detect Defects of Metallic Materials in the Mechanical Field. First of all, according to the biologically visually significant low-level features, the mark of defect experience marking is used as the intermediate feature of simulated visual perception. Afterwards, SVM method was used to train the advanced features of visual defects of metal material. According to the weight of each party, the biometrics detection model of metal material defect, which simulates human visual characteristics, is obtained.

  18. Strand Displacement Amplification Reaction on Quantum Dot-Encoded Silica Bead for Visual Detection of Multiplex MicroRNAs.

    PubMed

    Qu, Xiaojun; Jin, Haojun; Liu, Yuqian; Sun, Qingjiang

    2018-03-06

    The combination of microbead array, isothermal amplification, and molecular signaling enables the continuous development of next-generation molecular diagnostic techniques. Herein we reported the implementation of nicking endonuclease-assisted strand displacement amplification reaction on quantum dots-encoded microbead (Qbead), and demonstrated its feasibility for multiplexed miRNA assay in real sample. The Qbead featured with well-defined core-shell superstructure with dual-colored quantum dots loaded in silica core and shell, respectively, exhibiting remarkably high optical encoding stability. Specially designed stem-loop-structured probes were immobilized onto the Qbead for specific target recognition and amplification. In the presence of low abundance of miRNA target, the target triggered exponential amplification, producing a large quantity of stem-G-quadruplexes, which could be selectively signaled by a fluorescent G-quadruplex intercalator. In one-step operation, the Qbead-based isothermal amplification and signaling generated emissive "core-shell-satellite" superstructure, changing the Qbead emission-color. The target abundance-dependent emission-color changes of the Qbead allowed direct, visual detection of specific miRNA target. This visualization method achieved limit of detection at the subfemtomolar level with a linear dynamic range of 4.5 logs, and point-mutation discrimination capability for precise miRNA analyses. The array of three encoded Qbeads could simultaneously quantify three miRNA biomarkers in ∼500 human hepatoma carcinoma cells. With the advancements in ease of operation, multiplexing, and visualization capabilities, the isothermal amplification-on-Qbead assay could potentially enable the development of point-of-care diagnostics.

  19. Evaluation of dental explorer and visual inspection for the detection of residual caries among Greek dentists

    PubMed Central

    Ntovas, Panagiotis; Loubrinis, Nikolaos; Maniatakos, Panagiotis; Rahiotis, Christos

    2018-01-01

    Objectives: The objective of this study was to assess the effect of the operator's degree of clinical experience on the residual caries diagnosis through visual inspection and tactile sensation. Materials and Methods: The participants were asked about the years of their clinical practice, any further training concerning cariology, their familiarity with the minimal invasive philosophy, and the techniques that they use to remove dental caries and detect when to stop the removal of carious tissues. In addition, an in vitro diagnostic test was conducted. Carious teeth were excavated to a level selected in random. Teeth were examined by each participant individually. Initial examination was performed by visual inspection. Subsequently, a dental explorer was used concerning the potential need for further removal of dental tissues. A sample of 380 dentists and dental school students were selected for the purposes of this study. Results: Dental students presented statistically significant better sensitivity, than dentists from both age groups, during both visual inspection and tactile sensation of residual caries. Participants' ability to diagnose residual caries during cavity preparation was independent of their years of experience. Conclusions: During the removal of carious lesions, with the goal of limiting the sacrifice of healthy structures and the leftover of residual caries, clinicians should combine a selective removal technique and the attentive visual inspection, with at least one further diagnostic method, aside from the dental explorer. Tactile examination of residual caries solely with the dental explorer must be used with attention. PMID:29899636

  20. Rapid visual and spectrophotometric nitrite detection by cyclometalated ruthenium complex.

    PubMed

    Lo, Hoi-Shing; Lo, Ka-Wai; Yeung, Chi-Fung; Wong, Chun-Yuen

    2017-10-16

    Quantitative determination of nitrite ion (NO 2 - ) is of great importance in environmental and clinical investigations. A rapid visual and spectrophotometric assay for NO 2 - detection was developed based on a newly designed ruthenium complex, [Ru(npy)([9]aneS3)(CO)](ClO 4 ) (denoted as RuNPY; npy = 2-(1-naphthyl)pyridine, [9]aneS3 = 1,4,7-trithiacyclononane). This complex traps NO + produced in acidified NO 2 - solution, and yields observable color change within 1 min at room temperature. The assay features excellent dynamic range (1-840 μmol L -1 ) and high selectivity, and its limit of detection (0.39 μmol L -1 ) is also well below the guideline values for drinking water recommended by WHO and U.S. EPA. Practical use of this assay in tap water and human urine was successfully demonstrated. Overall, the rapidity and selectivity of this assay overcome the problems suffered by the commonly used modified Griess assays for nitrite determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Estimated capacity of object files in visual short-term memory is not improved by retrieval cueing.

    PubMed

    Saiki, Jun; Miyatsuji, Hirofumi

    2009-03-23

    Visual short-term memory (VSTM) has been claimed to maintain three to five feature-bound object representations. Some results showing smaller capacity estimates for feature binding memory have been interpreted as the effects of interference in memory retrieval. However, change-detection tasks may not properly evaluate complex feature-bound representations such as triple conjunctions in VSTM. To understand the general type of feature-bound object representation, evaluation of triple conjunctions is critical. To test whether interference occurs in memory retrieval for complete object file representations in a VSTM task, we cued retrieval in novel paradigms that directly evaluate the memory for triple conjunctions, in comparison with a simple change-detection task. In our multiple object permanence tracking displays, observers monitored for a switch in feature combination between objects during an occlusion period, and we found that a retrieval cue provided no benefit with the triple conjunction tasks, but significant facilitation with the change-detection task, suggesting that low capacity estimates of object file memory in VSTM reflect a limit on maintenance, not retrieval.

  2. Visual detection of organophosphorus pesticides represented by mathamidophos using Au nanoparticles as colorimetric probe.

    PubMed

    Li, Hongkun; Guo, Jiajia; Ping, Hong; Liu, Lurui; Zhang, Minwei; Guan, Fengrui; Sun, Chunyan; Zhang, Qian

    2011-12-15

    With citrate-coated Au nanoparticles as colorimetric probe, a novel visual method for rapid assay of organophosphorus pesticides has been developed. The assay principle is based on catalytic hydrolysis of acetylthiocholine into thiocholine by acetylcholinesterase, which induces the aggregation of Au nanoparticles and the color change from claret-red to purple or even grey. The original plasmon absorption of Au nanoparticles at 522 nm decreases, and simultaneously, a new absorption band appears at 675 nm. The irreversible inhibition of organophosphorus pesticides on acetylcholinesterase prevents aggregation of Au nanoparticles. Under optimum conditions, the absorbance at 522 nm of Au nanoparticles is related linearly to the concentration of mathamidophos in the range of 0.02-1.42 μg/mL with a detection limit of 1.40 ng/mL. This colorimetric method has been successfully utilized to detect mathamidophos in vegetables with satisfactory results. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for the analysis of organophosphorus pesticides. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Spatial limitations of fast temporal segmentation are best modeled by V1 receptive fields.

    PubMed

    Goodbourn, Patrick T; Forte, Jason D

    2013-11-22

    The fine temporal structure of events influences the spatial grouping and segmentation of visual-scene elements. Although adjacent regions flickering asynchronously at high temporal frequencies appear identical, the visual system signals a boundary between them. These "phantom contours" disappear when the gap between regions exceeds a critical value (g(max)). We used g(max) as an index of neuronal receptive-field size to compare with known receptive-field data from along the visual pathway and thus infer the location of the mechanism responsible for fast temporal segmentation. Observers viewed a circular stimulus reversing in luminance contrast at 20 Hz for 500 ms. A gap of constant retinal eccentricity segmented each stimulus quadrant; on each trial, participants identified a target quadrant containing counterphasing inner and outer segments. Through varying the gap width, g(max) was determined at a range of retinal eccentricities. We found that g(max) increased from 0.3° to 0.8° for eccentricities from 2° to 12°. These values correspond to receptive-field diameters of neurons in primary visual cortex that have been reported in single-cell and fMRI studies and are consistent with the spatial limitations of motion detection. In a further experiment, we found that modulation sensitivity depended critically on the length of the contour and could be predicted by a simple model of spatial summation in early cortical neurons. The results suggest that temporal segmentation is achieved by neurons at the earliest cortical stages of visual processing, most likely in primary visual cortex.

  4. A method to determine the impact of reduced visual function on nodule detection performance.

    PubMed

    Thompson, J D; Lança, C; Lança, L; Hogg, P

    2017-02-01

    In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (-1.00 D and -2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1-4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to -1.00 D and for one observer when defocussed to -2.00 D. Stereoacuity was unacceptable for one observer when defocussed to -2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  5. DEEP NEAR-IR OBSERVATIONS OF THE GLOBULAR CLUSTER M4: HUNTING FOR BROWN DWARFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dieball, A.; Bedin, L. R.; Knigge, C.

    2016-01-20

    We present an analysis of deep Hubble Space Telescope (HST)/Wide Field Camera 3 near-IR (NIR) imaging data of the globular cluster (GC) M4. The best-photometry NIR color–magnitude diagram (CMD) clearly shows the main sequence extending toward the expected end of the hydrogen-burning limit and going beyond this point toward fainter sources. The white dwarf (WD) sequence can be identified. As such, this is the deepest NIR CMD of a GC to date. Archival HST optical data were used for proper-motion cleaning of the CMD and for distinguishing the WDs from brown dwarf (BD) candidates. Detection limits in the NIR aremore » around F110W ≈ 26.5 mag and F160W ≈ 27 mag, and in the optical around F775W ≈ 28 mag. Comparing our observed CMDs with theoretical models, we conclude that we have reached beyond the H-burning limit in our NIR CMD and are probably just above or around this limit in our optical–NIR CMDs. Thus, any faint NIR sources that have no optical counterpart are potential BD candidates, since the optical data are not deep enough to detect them. We visually inspected the positions of NIR sources that are fainter than the H-burning limit in F110W and for which the optical photometry did not return a counterpart. We found in total five sources for which we did not get an optical measurement. For four of these five sources, a faint optical counterpart could be visually identified, and an upper optical magnitude was estimated. Based on these upper optical magnitude limits, we conclude that one source is likely a WD, one source could be either a WD or BD candidate, and the remaining two sources agree with being BD candidates. No optical counterpart could be detected for just one source, which makes this source a good BD candidate. We conclude that we found in total four good BD candidates.« less

  6. Loop-Mediated Isothermal Amplification Label-Based Gold Nanoparticles Lateral Flow Biosensor for Detection of Enterococcus faecalis and Staphylococcus aureus

    PubMed Central

    Wang, Yi; Li, Hui; Wang, Yan; Zhang, Lu; Xu, Jianguo; Ye, Changyun

    2017-01-01

    The report describes a simple, rapid and sensitive assay for visual and multiplex detection of Enterococcus faecalis and Staphylococcus aureus based on multiple loop-mediated isothermal amplification (mLAMP) and lateral flow biosensor (LFB). Detection and differentiation of the Ef0027 gene (E. faecalis-specific gene) and nuc gene (S. aureus-specific gene) were determined using fluorescein (FITC)-and digoxin-modified primers in the mLAMP process. In the presence of biotin- and FITC-/digoxin-modified primers, the mLAMP yielded numerous biotin- and FITC-/digoxin-attached duplex products, which were detected by LFB through biotin/streptavidin interaction (biotin on the duplex and streptavidin on the gold nanoparticle) and immunoreactions (FITC/digoxin on the duplex and anti-FITC/digoxin on the LFB test line). The accumulation of gold nanoparticles generated a characteristic red line, enabling visual and multiplex detection of target pathogens without instrumentation. The limit of detection (LoD), analytical specificity and feasibility of LAMP-LFB technique were successfully examined in pure culture and blood samples. The entire procedure, including specimen (blood samples) processing (30 min), isothermal reaction (40 min) and result reporting (within 2 min), could be completed within 75 min. Thus, this assay offers a simple, rapid, sensitive and specific test for multiplex detection of E. faecalis and S. aureus strains. Furthermore, the LAMP-LFB strategy is a universal technique, which can be extended to detect various target sequences by re-designing the specific LAMP primers. PMID:28239371

  7. A gold nanoparticle-based semi-quantitative and quantitative ultrasensitive paper sensor for the detection of twenty mycotoxins

    NASA Astrophysics Data System (ADS)

    Kong, Dezhao; Liu, Liqiang; Song, Shanshan; Suryoprabowo, Steven; Li, Aike; Kuang, Hua; Wang, Libing; Xu, Chuanlai

    2016-02-01

    A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination.A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr09171c

  8. Wide-band gas leak imaging detection system using UFPA

    NASA Astrophysics Data System (ADS)

    Jin, Wei-qi; Li, Jia-kun; Dun, Xiong; Jin, Minglei; Wang, Xia

    2014-11-01

    The leakage of toxic or hazardous gases not only pollutes the environment, but also threatens people's lives and property safety. Many countries attach great importance to the rapid and effective gas leak detection technology and instrument development. However, the gas leak imaging detection systems currently existing are generally limited to a narrow-band in Medium Wavelength Infrared (MWIR) or Long Wavelength Infrared (LWIR) cooled focal plane imaging, which is difficult to detect the common kinds of the leaking gases. Besides the costly cooled focal plane array is utilized, the application promotion is severely limited. To address this issue, a wide-band gas leak IR imaging detection system using Uncooled Focal Plane Array (UFPA) detector is proposed, which is composed of wide-band IR optical lens, sub-band filters and switching device, wide-band UFPA detector, video processing and system control circuit. A wide-band (3µm~12µm) UFPA detector is obtained by replacing the protection window and optimizing the structural parameters of the detector. A large relative aperture (F#=0.75) wide-band (3μm~12μm) multispectral IR lens is developed by using the focus compensation method, which combining the thickness of the narrow-band filters. The gas leak IR image quality and the detection sensitivity are improved by using the IR image Non-Uniformity Correction (NUC) technology and Digital Detail Enhancement (DDE) technology. The wide-band gas leak IR imaging detection system using UFPA detector takes full advantage of the wide-band (MWIR&LWIR) response characteristic of the UFPA detector and the digital image processing technology to provide the resulting gas leak video easy to be observed for the human eyes. Many kinds of gases, which are not visible to the naked eyes, can be sensitively detected and visualized. The designed system has many commendable advantages, such as scanning a wide range simultaneously, locating the leaking source quickly, visualizing the gas plume intuitively and so on. The simulation experiment shows that the gas IR imaging detection has great advantages and widely promotion space compared with the traditional techniques, such as point-contact or line-contactless detection.

  9. Visual motion detection and habitat preference in Anolis lizards.

    PubMed

    Steinberg, David S; Leal, Manuel

    2016-11-01

    The perception of visual stimuli has been a major area of inquiry in sensory ecology, and much of this work has focused on coloration. However, for visually oriented organisms, the process of visual motion detection is often equally crucial to survival and reproduction. Despite the importance of motion detection to many organisms' daily activities, the degree of interspecific variation in the perception of visual motion remains largely unexplored. Furthermore, the factors driving this potential variation (e.g., ecology or evolutionary history) along with the effects of such variation on behavior are unknown. We used a behavioral assay under laboratory conditions to quantify the visual motion detection systems of three species of Puerto Rican Anolis lizard that prefer distinct structural habitat types. We then compared our results to data previously collected for anoles from Cuba, Puerto Rico, and Central America. Our findings indicate that general visual motion detection parameters are similar across species, regardless of habitat preference or evolutionary history. We argue that these conserved sensory properties may drive the evolution of visual communication behavior in this clade.

  10. An Ru(II)-Fe(III) bimetallic complex as a multifunctional device for detecting, signal amplifying, and degrading oxalate.

    PubMed

    Chow, Cheuk-Fai; Ho, Pui-Yu; Gong, Cheng-Bin

    2014-09-07

    A tetranuclear bimetallic complex, [Ru(II)((t)Bubpy)(CN)4]2-[Fe(III)(H2O)3Cl]2·8H2O (1) has been synthesized and characterized. It was found to be a multifunctional device that can detect, signal amplify, and degrade an organic pollutant, oxalate. Results of the chemosensing studies of 1 toward common anions show that only oxalate selectively induces naked-eye colorimetric and luminometric responses with method detection limits down to 78.7 and 5.5 ppm, respectively from 1. Meanwhile, results of the photo-degradation studies of 1 toward oxalate show that the dissolved organic carbon content of oxalate decreased and reached complete mineralization into CO2 within 6 hours. Complex 1 was also found as the catalyst that amplified the detection signal toward oxalate. Through the photoassisted Fenton reaction by 1, methyl orange, an additional coloring agent, could be degraded so that the visual detection limit of 1 toward oxalate was magnified 50 times from 100 to 2 ppm. The detection, degradation, mineralization and signal amplification were found applicable in real water bodies such as river, pond and underground water with excellent recoveries and relative standard deviation.

  11. Simple summation rule for optimal fixation selection in visual search.

    PubMed

    Najemnik, Jiri; Geisler, Wilson S

    2009-06-01

    When searching for a known target in a natural texture, practiced humans achieve near-optimal performance compared to a Bayesian ideal searcher constrained with the human map of target detectability across the visual field [Najemnik, J., & Geisler, W. S. (2005). Optimal eye movement strategies in visual search. Nature, 434, 387-391]. To do so, humans must be good at choosing where to fixate during the search [Najemnik, J., & Geisler, W.S. (2008). Eye movement statistics in humans are consistent with an optimal strategy. Journal of Vision, 8(3), 1-14. 4]; however, it seems unlikely that a biological nervous system would implement the computations for the Bayesian ideal fixation selection because of their complexity. Here we derive and test a simple heuristic for optimal fixation selection that appears to be a much better candidate for implementation within a biological nervous system. Specifically, we show that the near-optimal fixation location is the maximum of the current posterior probability distribution for target location after the distribution is filtered by (convolved with) the square of the retinotopic target detectability map. We term the model that uses this strategy the entropy limit minimization (ELM) searcher. We show that when constrained with human-like retinotopic map of target detectability and human search error rates, the ELM searcher performs as well as the Bayesian ideal searcher, and produces fixation statistics similar to human.

  12. Modelling detection probabilities to evaluate management and control tools for an invasive species

    USGS Publications Warehouse

    Christy, M.T.; Yackel Adams, A.A.; Rodda, G.H.; Savidge, J.A.; Tyrrell, C.L.

    2010-01-01

    For most ecologists, detection probability (p) is a nuisance variable that must be modelled to estimate the state variable of interest (i.e. survival, abundance, or occupancy). However, in the realm of invasive species control, the rate of detection and removal is the rate-limiting step for management of this pervasive environmental problem. For strategic planning of an eradication (removal of every individual), one must identify the least likely individual to be removed, and determine the probability of removing it. To evaluate visual searching as a control tool for populations of the invasive brown treesnake Boiga irregularis, we designed a mark-recapture study to evaluate detection probability as a function of time, gender, size, body condition, recent detection history, residency status, searcher team and environmental covariates. We evaluated these factors using 654 captures resulting from visual detections of 117 snakes residing in a 5-ha semi-forested enclosure on Guam, fenced to prevent immigration and emigration of snakes but not their prey. Visual detection probability was low overall (= 0??07 per occasion) but reached 0??18 under optimal circumstances. Our results supported sex-specific differences in detectability that were a quadratic function of size, with both small and large females having lower detection probabilities than males of those sizes. There was strong evidence for individual periodic changes in detectability of a few days duration, roughly doubling detection probability (comparing peak to non-elevated detections). Snakes in poor body condition had estimated mean detection probabilities greater than snakes with high body condition. Search teams with high average detection rates exhibited detection probabilities about twice that of search teams with low average detection rates. Surveys conducted with bright moonlight and strong wind gusts exhibited moderately decreased probabilities of detecting snakes. Synthesis and applications. By emphasizing and modelling detection probabilities, we now know: (i) that eradication of this species by searching is possible, (ii) how much searching effort would be required, (iii) under what environmental conditions searching would be most efficient, and (iv) several factors that are likely to modulate this quantification when searching is applied to new areas. The same approach can be use for evaluation of any control technology or population monitoring programme. ?? 2009 The Authors. Journal compilation ?? 2009 British Ecological Society.

  13. Blue Whale Visual and Acoustic Encounter Rates in the Southern California Bight

    DTIC Science & Technology

    2007-07-01

    blue whale (Balaenoptera musculus) visual and acoustic encounter rates was quantitatively evaluated using hourly counts of detected whales during...surveys occurring in April, there were visual and acoustic detections of blue whales in all surveyed months and regions. Encounter rate is...difference between acoustic encounters of singing whales and visual encounters suggest seasonal variation in the ability of each method to detect blue

  14. A highly sensitive and temporal visualization system for gaseous ethanol with chemiluminescence enhancer.

    PubMed

    Arakawa, Takahiro; Ando, Eri; Wang, Xin; Kumiko, Miyajima; Kudo, Hiroyuki; Saito, Hirokazu; Mitani, Tomoyo; Takahashi, Mitsuo; Mitsubayashi, Kohji

    2012-01-01

    A two-dimensional gaseous ethanol visualization system has been developed and demonstrated using a horseradish peroxidase-luminol-hydrogen peroxide system with high-purity luminol solution and a chemiluminescence (CL) enhancer. This system measures ethanol concentrations as intensities of CL via the luminol reaction. CL was emitted when the gaseous ethanol was injected onto an enzyme-immobilized membrane, which was employed as a screen for two-dimensional gas visualization. The average intensity of CL on the substrate was linearly related to the concentration of standard ethanol gas. These results were compared with the CL intensity of the CCD camera recording image in the visualization system. This system is available for gas components not only for spatial but also for temporal analysis in real time. A high-purity sodium salt HG solution (L-HG) instead of standard luminol solution and an enhancer, eosin Y (EY) solution, were adapted for improvement of CL intensity of the system. The visualization of gaseous ethanol was achieved at a detection limit of 3 ppm at optimized concentrations of L-HG solution and EY. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Sensitive naked eye detection and quantification assay for nitrite by a fluorescence probe in various water resources

    NASA Astrophysics Data System (ADS)

    Zhang, Fengyuan; Zhu, Xinyue; Jiao, Zhijuan; Liu, Xiaoyan; Zhang, Haixia

    2018-07-01

    An uncontrolled increase of nitrite concentration in groundwater, rivers and lakes is a growing threat to public health and environment. It is important to monitor the nitrite levels in water and clinical diagnosis. Herein, we developed a switch-off fluorescence probe (PyI) for the sensitive detection of nitrite ions in the aqueous media. This probe selectively recognizes nitrite ions through a distinct visual color change from colorless to pink with a detection limit of 0.1 μM. This method has been successfully applied to the determination of nitrites in tap water, lake water and Yellow River water with recoveries in the range of 94.8%-105.4%.

  16. Intrinsic protein fluorescence interferes with detection of tear glycoproteins in SDS-polyacrylamide gels using extrinsic fluorescent dyes.

    PubMed

    Zhao, Zhenjun; Aliwarga, Yulina; Willcox, Mark D P

    2007-12-01

    Intrinsic protein fluorescence may interfere with the visualization of proteins after SDS-polyacrylamide electrophoresis. In an attempt to analyze tear glycoproteins in gels, we ran tear samples and stained the proteins with a glycoprotein-specific fluorescent dye. The fluorescence detected was not limited to glycoproteins. There was strong intrinsic fluorescence of proteins normally found in tears after soaking the gels in 40% methanol plus 1-10% acetic acid and, to a lesser extent, in methanol or acetic acid alone. Nanograms of proteins gave visible native fluorescence and interfere with extrinsic fluorescent dye detection. Poly-L-lysine, which does not contain intrinsically fluorescent amino acids, did not fluoresce.

  17. Intrinsic Protein Fluorescence Interferes with Detection of Tear Glycoproteins in SDS-Polyacrylamide Gels Using Extrinsic Fluorescent Dyes

    PubMed Central

    Zhao, Zhenjun; Aliwarga, Yulina; Willcox, Mark DP

    2007-01-01

    Intrinsic protein fluorescence may interfere with the visualization of proteins after SDS-polyacrylamide electrophoresis. In an attempt to analyze tear glycoproteins in gels, we ran tear samples and stained the proteins with a glycoprotein-specific fluorescent dye. The fluorescence detected was not limited to glycoproteins. There was strong intrinsic fluorescence of proteins normally found in tears after soaking the gels in 40% methanol plus 1–10% acetic acid and, to a lesser extent, in methanol or acetic acid alone. Nanograms of proteins gave visible native fluorescence and interfere with extrinsic fluorescent dye detection. Poly-L-lysine, which does not contain intrinsically fluorescent amino acids, did not fluoresce. PMID:18166676

  18. Simple and Sensitive Paper-Based Device Coupling Electrochemical Sample Pretreatment and Colorimetric Detection.

    PubMed

    Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C

    2016-05-17

    We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.

  19. Change blindness and visual memory: visual representations get rich and act poor.

    PubMed

    Varakin, D Alexander; Levin, Daniel T

    2006-02-01

    Change blindness is often taken as evidence that visual representations are impoverished, while successful recognition of specific objects is taken as evidence that they are richly detailed. In the current experiments, participants performed cover tasks that required each object in a display to be attended. Change detection trials were unexpectedly introduced and surprise recognition tests were given for nonchanging displays. For both change detection and recognition, participants had to distinguish objects from the same basic-level category, making it likely that specific visual information had to be used for successful performance. Although recognition was above chance, incidental change detection usually remained at floor. These results help reconcile demonstrations of poor change detection with demonstrations of good memory because they suggest that the capability to store visual information in memory is not reflected by the visual system's tendency to utilize these representations for purposes of detecting unexpected changes.

  20. Macular Hole Development After Vitrectomy for Floaters: A Case Report.

    PubMed

    Appeltans, Andrea; Mura, Marco; Bamonte, Giulio

    2017-12-01

    The purpose of this report is to describe a case of macular hole development after vitrectomy for floaters with induction of posterior vitreous detachment. A 44-year-old otherwise healthy man presented with visually debilitating floaters in his right eye; these had been present for more than 2 years. Preoperative examination was unremarkable in both eyes, apart from some degree of vitreous degeneration in the right eye. Preoperative visual acuity was 20/20 bilaterally. A 25-gauge transconjunctival sutureless pars plana complete vitrectomy with induction of posterior vitreous detachment was performed in the right eye. Upon examination 1 month after surgery, a small full-thickness macular hole was detected in the right eye. Visual acuity was diminished to 20/80. The macular hole was closed after a second vitrectomy with internal limiting membrane peeling and gas tamponade. Macular hole development should be listed as a possible complication of vitrectomy for visually debilitating floaters when a posterior vitreous detachment is induced during surgery.

  1. Ventral and Dorsal Visual Stream Contributions to the Perception of Object Shape and Object Location

    PubMed Central

    Zachariou, Valentinos; Klatzky, Roberta; Behrmann, Marlene

    2017-01-01

    Growing evidence suggests that the functional specialization of the two cortical visual pathways may not be as distinct as originally proposed. Here, we explore possible contributions of the dorsal “where/how” visual stream to shape perception and, conversely, contributions of the ventral “what” visual stream to location perception in human adults. Participants performed a shape detection task and a location detection task while undergoing fMRI. For shape detection, comparable BOLD activation in the ventral and dorsal visual streams was observed, and the magnitude of this activation was correlated with behavioral performance. For location detection, cortical activation was significantly stronger in the dorsal than ventral visual pathway and did not correlate with the behavioral outcome. This asymmetry in cortical profile across tasks is particularly noteworthy given that the visual input was identical and that the tasks were matched for difficulty in performance. We confirmed the asymmetry in a subsequent psychophysical experiment in which participants detected changes in either object location or shape, while ignoring the other, task-irrelevant dimension. Detection of a location change was slowed by an irrelevant shape change matched for difficulty, but the reverse did not hold. We conclude that both ventral and dorsal visual streams contribute to shape perception, but that location processing appears to be essentially a function of the dorsal visual pathway. PMID:24001005

  2. Magnetic beads-based DNAzyme recognition and AuNPs-based enzymatic catalysis amplification for visual detection of trace uranyl ion in aqueous environment.

    PubMed

    Zhang, Hongyan; Lin, Ling; Zeng, Xiaoxue; Ruan, Yajuan; Wu, Yongning; Lin, Minggui; He, Ye; Fu, FengFu

    2016-04-15

    We herein developed a novel biosensor for the visual detection of trace uranyl ion (UO2(2+)) in aqueous environment with high sensitivity and specificity by using DNAzyme-functionalized magnetic beads (MBs) for UO2(2+) recognition and gold nano-particles (AuNPs)-based enzymatic catalysis oxidation of TMB (3,3',5,5'-tetramethylbenzidine sulfate) for signal generation. The utilization of MBs facilitates the magnetic separation and collection of sensing system from complex sample solution, which leads to more convenient experimental operation and more strong resistibility of the biosensor to the matrix of sample, and the utilization of AuNPs-based enzymatic catalysis amplification greatly improved the sensitivity of the biosensor. Compared with the previous DNAzyme-based UO2(2+) sensors, the proposed biosensor has outstanding advantages such as relative high sensitivity and specificity, operation convenience, low cost and more strong resistibility to the matrix of sample. It can be used to detect as low as 0.02 ppb (74 pM) of UO2(2+) in aqueous environment by only naked-eye observation and 1.89 ppt (7.0 pM) of UO2(2+) by UV-visible spectrophotometer with a recovery of 93-99% and a RSD ≤ 5.0% (n=6) within 3h. Especially, the visual detection limit of 0.02 ppb (74 pM) is much lower than the maximum allowable level of UO2(2+) (130 nM) in the drinking water defined by the U.S. Environmental Protection Agency (EPA), indicating that our method meets the requirement of rapid and on-site detection of UO2(2+) in the aqueous environment by only naked-eye observation. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Unsupervised Gaussian Mixture-Model With Expectation Maximization for Detecting Glaucomatous Progression in Standard Automated Perimetry Visual Fields.

    PubMed

    Yousefi, Siamak; Balasubramanian, Madhusudhanan; Goldbaum, Michael H; Medeiros, Felipe A; Zangwill, Linda M; Weinreb, Robert N; Liebmann, Jeffrey M; Girkin, Christopher A; Bowd, Christopher

    2016-05-01

    To validate Gaussian mixture-model with expectation maximization (GEM) and variational Bayesian independent component analysis mixture-models (VIM) for detecting glaucomatous progression along visual field (VF) defect patterns (GEM-progression of patterns (POP) and VIM-POP). To compare GEM-POP and VIM-POP with other methods. GEM and VIM models separated cross-sectional abnormal VFs from 859 eyes and normal VFs from 1117 eyes into abnormal and normal clusters. Clusters were decomposed into independent axes. The confidence limit (CL) of stability was established for each axis with a set of 84 stable eyes. Sensitivity for detecting progression was assessed in a sample of 83 eyes with known progressive glaucomatous optic neuropathy (PGON). Eyes were classified as progressed if any defect pattern progressed beyond the CL of stability. Performance of GEM-POP and VIM-POP was compared to point-wise linear regression (PLR), permutation analysis of PLR (PoPLR), and linear regression (LR) of mean deviation (MD), and visual field index (VFI). Sensitivity and specificity for detecting glaucomatous VFs were 89.9% and 93.8%, respectively, for GEM and 93.0% and 97.0%, respectively, for VIM. Receiver operating characteristic (ROC) curve areas for classifying progressed eyes were 0.82 for VIM-POP, 0.86 for GEM-POP, 0.81 for PoPLR, 0.69 for LR of MD, and 0.76 for LR of VFI. GEM-POP was significantly more sensitive to PGON than PoPLR and linear regression of MD and VFI in our sample, while providing localized progression information. Detection of glaucomatous progression can be improved by assessing longitudinal changes in localized patterns of glaucomatous defect identified by unsupervised machine learning.

  4. Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique.

    PubMed

    Thienprasiddhi, Phamornsak; Greenstein, Vivienne C; Chu, David H; Xu, Li; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2006-08-01

    To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. Twenty-five GS patients (25 eyes), 25 patients with OHT (25 eyes), and 50 normal controls (50 eyes) were enrolled in this study. All GS, OHT and normal control eyes had normal SAP as defined by a pattern standard deviation and mean deviation within the 95% confidence interval and a glaucoma hemifield test within normal limits on the Humphrey visual field 24-2 program. Eyes with GS had optic disc changes consistent with glaucoma with or without raised intraocular pressure (IOP), and eyes with OHT showed no evidence of glaucomatous optic neuropathy and IOPs >or=22 mm Hg. Monocular mfVEPs were obtained from both eyes of each subject using a pattern-reversal dartboard array with 60 sectors. The entire display had a radius of 22.3 degrees. The mfVEPs, for each eye, were defined as abnormal when either the monocular or interocular probability plot had a cluster of 3 or more contiguous points with P<0.05 and at least 2 of these points with P<0.01. The mfVEP results were abnormal in 4% of the eyes from normal subjects. Abnormal mfVEPs were detected in 20% of the eyes of GS patients and 16% of the eyes of OHT patients. Significantly more mfVEP abnormalities were detected in GS patients than in normal controls. However, there was no significant difference in mfVEP results between OHT patients and normal controls. The mfVEP technique can detect visual field deficits in a minority of eyes with glaucomatous optic disks and normal SAP results.

  5. Visual Sensitivities and Discriminations and Their Roles in Aviation.

    DTIC Science & Technology

    1986-03-01

    D. Low contrast letter charts in early diabetic retinopathy , octrlar hypertension, glaucoma and Parkinson’s disease. Br J Ophthalmol, 1984, 68, 885...to detect a camouflaged object that was visible only when moving, and compared these data with similar measurements for conventional objects that were...3) Compare visual detection (i.e. visual acquisition) of camouflaged objects whose edges are defined by velocity differences with visual detection

  6. Visual Detection Under Uncertainty Operates Via an Early Static, Not Late Dynamic, Non-Linearity

    PubMed Central

    Neri, Peter

    2010-01-01

    Signals in the environment are rarely specified exactly: our visual system may know what to look for (e.g., a specific face), but not its exact configuration (e.g., where in the room, or in what orientation). Uncertainty, and the ability to deal with it, is a fundamental aspect of visual processing. The MAX model is the current gold standard for describing how human vision handles uncertainty: of all possible configurations for the signal, the observer chooses the one corresponding to the template associated with the largest response. We propose an alternative model in which the MAX operation, which is a dynamic non-linearity (depends on multiple inputs from several stimulus locations) and happens after the input stimulus has been matched to the possible templates, is replaced by an early static non-linearity (depends only on one input corresponding to one stimulus location) which is applied before template matching. By exploiting an integrated set of analytical and experimental tools, we show that this model is able to account for a number of empirical observations otherwise unaccounted for by the MAX model, and is more robust with respect to the realistic limitations imposed by the available neural hardware. We then discuss how these results, currently restricted to a simple visual detection task, may extend to a wider range of problems in sensory processing. PMID:21212835

  7. Spectral tuning in the eyes of deep-sea lanternfishes (Myctophidae): a novel sexually dimorphic intra-ocular filter.

    PubMed

    de Busserolles, Fanny; Hart, Nathan S; Hunt, David M; Davies, Wayne I; Marshall, N Justin; Clarke, Michael W; Hahne, Dorothee; Collin, Shaun P

    2015-01-01

    Deep-sea fishes possess several adaptations to facilitate vision where light detection is pushed to its limit. Lanternfishes (Myctophidae), one of the world's most abundant groups of mesopelagic fishes, possess a novel and unique visual specialisation, a sexually dimorphic photostable yellow pigmentation, constituting the first record of a visual sexual dimorphism in any non-primate vertebrate. The topographic distribution of the yellow pigmentation across the retina is species specific, varying in location, shape and size. Spectrophotometric analyses reveal that this new retinal specialisation differs between species in terms of composition and acts as a filter, absorbing maximally between 356 and 443 nm. Microspectrophotometry and molecular analyses indicate that the species containing this pigmentation also possess at least 2 spectrally distinct rod visual pigments as a result of a duplication of the Rh1 opsin gene. After modelling the effect of the yellow pigmentation on photoreceptor spectral sensitivity, we suggest that this unique specialisation acts as a filter to enhance contrast, thereby improving the detection of bioluminescent emissions and possibly fluorescence in the extreme environment of the deep sea. The fact that this yellow pigmentation is species specific, sexually dimorphic and isolated within specific parts of the retina indicates an evolutionary pressure to visualise prey/predators/mates in a particular part of each species' visual field.

  8. Relevance of cryptic fishes in biodiversity assessments: A case study at Buck Island Reef National Monument, St. Croix

    USGS Publications Warehouse

    Smith-Vaniz, W.F.; Jelks, H.L.; Rocha, L.A.

    2006-01-01

    Because cryptic fishes are difficult to accurately survey, they are undersampled components of coral reef habitats, and their ecological roles have been generally ignored. Fifty-eight enclosed stations were sampled in shoreline, nearshore reef, lagoon, backreef, forereef, and bank/shelf habitats with an ichthyocide (rotenone) at Buck Island Reef National Monument, St. Croix, U.S. Virgin Islands. Our samples included 55 families and 228 species, 60 previously unreported from St. Croix. Fish assemblages varied across habitat zones with the shoreline assemblage the most distinct. Only 8% of the species were present in all habitats. Multi-dimensional scaling plots of habitat characteristics and Bray-Curtis similarities of fish assemblages revealed similar patterns. Dominant and rare taxa are enumerated for each habitat sampled. Rotenone and visual census data are compared. While visual surveys accumulated more species per unit of effort, rotenone samples accumulated more species by area. Only 36% of the 228 species sampled with rotenone were visually detected, while 70% of the 115 species visually detected were also collected with rotenone. The use of rotenone is controversial but important for obtaining reasonably complete inventories of reef fishes. Misconceptions about rotenone and the advantages and limitations of alternative biodiversity assessment methods are discussed. ?? 2006 Rosenstiel School of Marine and Atmospheric Science of the University of Miami.

  9. Obstacle Avoidance, Visual Detection Performance, and Eye-Scanning Behavior of Glaucoma Patients in a Driving Simulator: A Preliminary Study

    PubMed Central

    Prado Vega, Rocío; van Leeuwen, Peter M.; Rendón Vélez, Elizabeth; Lemij, Hans G.; de Winter, Joost C. F.

    2013-01-01

    The objective of this study was to evaluate differences in driving performance, visual detection performance, and eye-scanning behavior between glaucoma patients and control participants without glaucoma. Glaucoma patients (n = 23) and control participants (n = 12) completed four 5-min driving sessions in a simulator. The participants were instructed to maintain the car in the right lane of a two-lane highway while their speed was automatically maintained at 100 km/h. Additional tasks per session were: Session 1: none, Session 2: verbalization of projected letters, Session 3: avoidance of static obstacles, and Session 4: combined letter verbalization and avoidance of static obstacles. Eye-scanning behavior was recorded with an eye-tracker. Results showed no statistically significant differences between patients and control participants for lane keeping, obstacle avoidance, and eye-scanning behavior. Steering activity, number of missed letters, and letter reaction time were significantly higher for glaucoma patients than for control participants. In conclusion, glaucoma patients were able to avoid objects and maintain a nominal lane keeping performance, but applied more steering input than control participants, and were more likely than control participants to miss peripherally projected stimuli. The eye-tracking results suggest that glaucoma patients did not use extra visual search to compensate for their visual field loss. Limitations of the study, such as small sample size, are discussed. PMID:24146975

  10. Scene and human face recognition in the central vision of patients with glaucoma

    PubMed Central

    Aptel, Florent; Attye, Arnaud; Guyader, Nathalie; Boucart, Muriel; Chiquet, Christophe; Peyrin, Carole

    2018-01-01

    Primary open-angle glaucoma (POAG) firstly mainly affects peripheral vision. Current behavioral studies support the idea that visual defects of patients with POAG extend into parts of the central visual field classified as normal by static automated perimetry analysis. This is particularly true for visual tasks involving processes of a higher level than mere detection. The purpose of this study was to assess visual abilities of POAG patients in central vision. Patients were assigned to two groups following a visual field examination (Humphrey 24–2 SITA-Standard test). Patients with both peripheral and central defects and patients with peripheral but no central defect, as well as age-matched controls, participated in the experiment. All participants had to perform two visual tasks where low-contrast stimuli were presented in the central 6° of the visual field. A categorization task of scene images and human face images assessed high-level visual recognition abilities. In contrast, a detection task using the same stimuli assessed low-level visual function. The difference in performance between detection and categorization revealed the cost of high-level visual processing. Compared to controls, patients with a central visual defect showed a deficit in both detection and categorization of all low-contrast images. This is consistent with the abnormal retinal sensitivity as assessed by perimetry. However, the deficit was greater for categorization than detection. Patients without a central defect showed similar performances to the controls concerning the detection and categorization of faces. However, while the detection of scene images was well-maintained, these patients showed a deficit in their categorization. This suggests that the simple loss of peripheral vision could be detrimental to scene recognition, even when the information is displayed in central vision. This study revealed subtle defects in the central visual field of POAG patients that cannot be predicted by static automated perimetry assessment using Humphrey 24–2 SITA-Standard test. PMID:29481572

  11. Angle imaging: Advances and challenges

    PubMed Central

    Quek, Desmond T L; Nongpiur, Monisha E; Perera, Shamira A; Aung, Tin

    2011-01-01

    Primary angle closure glaucoma (PACG) is a major form of glaucoma in large populous countries in East and South Asia. The high visual morbidity from PACG is related to the destructive nature of the asymptomatic form of the disease. Early detection of anatomically narrow angles is important and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). This review paper discusses the advantages and limitations of newer ACA imaging technologies, namely ultrasound biomicroscopy, Scheimpflug photography, anterior segment optical coherence tomography and EyeCam, highlighting the current clinical evidence comparing these devices with each other and with clinical dynamic indentation gonioscopy, the current reference standard. PMID:21150037

  12. Optical Coherence Tomography and Autofluorescence Imaging of Human Tonsil

    PubMed Central

    Pahlevaninezhad, Hamid; Lee, Anthony M. D.; Rosin, Miriam; Sun, Ivan; Zhang, Lewei; Hakimi, Mehrnoush; MacAulay, Calum; Lane, Pierre M.

    2014-01-01

    For the first time, we present co-registered autofluorescence imaging and optical coherence tomography (AF/OCT) of excised human palatine tonsils to evaluate the capabilities of OCT to visualize tonsil tissue components. Despite limited penetration depth, OCT can provide detailed structural information about tonsil tissue with much higher resolution than that of computed tomography, magnetic resonance imaging, and Ultrasound. Different tonsil tissue components such as epithelium, dense connective tissue, lymphoid nodules, and crypts can be visualized by OCT. The co-registered AF imaging can provide matching biochemical information. AF/OCT scans may provide a non-invasive tool for detecting tonsillar cancers and for studying the natural history of their development. PMID:25542010

  13. Mini-review: Far peripheral vision.

    PubMed

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Hydride Generation for Headspace Solid-Phase Extraction with CdTe Quantum Dots Immobilized on Paper for Sensitive Visual Detection of Selenium.

    PubMed

    Huang, Ke; Xu, Kailai; Zhu, Wei; Yang, Lu; Hou, Xiandeng; Zheng, Chengbin

    2016-01-05

    A low-cost, simple, and highly selective analytical method was developed for sensitive visual detection of selenium in human urine both outdoors and at home, by coupling hydride generation with headspace solid-phase extraction using quantum dots (QDs) immobilized on paper. The visible fluorescence from the CdTe QDs immobilized on paper was quenched by H2Se from hydride generation reaction and headspace solid-phase extraction. The potential mechanism was investigated by using X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) as well as Density Functional Theory (DFT). Potential interferences from coexisting ions, particularly Ag(+), Cu(2+), and Zn(2+), were eliminated. The selectivity was significantly increased because the selenium hydride was effectively separated from sample matrices by hydride generation. Moreover, due to the high sampling efficiency of hydride generation and headspace solid phase extraction, the sensitivity and the limit of detection (LOD) were significantly improved compared to conventional methods. A LOD of 0.1 μg L(-1) and a relative standard deviation (RSD, n = 7) of 2.4% at a concentration of 20 μg L(-1) were obtained when using a commercial spectrofluorometer as the detector. Furthermore, a visual assay based on the proposed method was developed for the detection of Se, 5 μg L(-1) of selenium in urine can be discriminated from the blank solution with the naked eye. The proposed method was validated by analysis of certified reference materials and human urine samples with satisfactory results.

  15. Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts

    NASA Astrophysics Data System (ADS)

    Jermyn, Michael; Desroches, Joannie; Mercier, Jeanne; Tremblay, Marie-Andrée; St-Arnaud, Karl; Guiot, Marie-Christine; Petrecca, Kevin; Leblond, Frederic

    2016-09-01

    Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences. In vivo Raman spectroscopy can detect these invasive cancer cells in patients with grade 2 to 4 gliomas. The robustness of this Raman signal can be dampened by spectral artifacts generated by lights in the operating room. We found that artificial neural networks (ANNs) can overcome these spectral artifacts using nonparametric and adaptive models to detect complex nonlinear spectral characteristics. Coupling ANN with Raman spectroscopy simplifies the intraoperative use of Raman spectroscopy by limiting changes required to the standard neurosurgical workflow. The ability to detect invasive brain cancer under these conditions may reduce residual cancer remaining after surgery and improve patient survival.

  16. Estimating a structural bottle neck for eye-brain transfer of visual information from 3D-volumes of the optic nerve head from a commercial OCT device

    NASA Astrophysics Data System (ADS)

    Malmberg, Filip; Sandberg-Melin, Camilla; Söderberg, Per G.

    2016-03-01

    The aim of this project was to investigate the possibility of using OCT optic nerve head 3D information captured with a Topcon OCT 2000 device for detection of the shortest distance between the inner limit of the retina and the central limit of the pigment epithelium around the circumference of the optic nerve head. The shortest distance between these boundaries reflects the nerve fiber layer thickness and measurement of this distance is interesting for follow-up of glaucoma.

  17. Simultaneous Detection of Multiple Disease States.

    DTIC Science & Technology

    1990-02-14

    analytes to be assayed in a panel forma And due to its simplicity, OIA has been demonstrated to be generally applicable to a wide range of testing...into two distinct formats on the basis of signal generation: visual and instrumented. In both cases monocrystalline silicon wafers are employed as...Due to the limited surface area available on the monocrystalline silicon wafers, attention must be paid to efficient immobilization to ensure

  18. Oral-Fluid Thiol-Detection Test Identifies Underlying Active Periodontal Disease Not Detected by the Visual Awake Examination.

    PubMed

    Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David

    Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.

  19. Limitations of the Neurological Evolutional Exam (ENE) as a motor assessment for first graders.

    PubMed

    Caçola, Priscila M; Bobbio, Tatiana G; Arias, Amabile V; Gonçalves, Vanda G; Gabbard, Carl

    2010-01-01

    many clinicians and researchers in Brazil consider the Neurological Developmental Exam (NDE), a valid and reliable assessment for Brazilian school-aged children. However, since its inception, several tests have emerged that, according to some researchers, provide more in-depth evaluation of motor ability and go beyond the detection of general motor status (soft neurological signs). to highlight the limitations of the NDE as a motor skill assessment for first graders. thirty-five children were compared on seven selected items of the NDE, seven of the Bruininks-Oseretsky Test (BOT), and seven of the Visual-Motor Integration test (VMI). Participants received a "pass" or "fail" score for each item, as prescribed by the respective test manual. chi-square and ANOVA results indicated that the vast majority of children (74%) passed the NDE items, whereas values for the other tests were 29% (BOT) and 20% (VMI). Analysis of specific categories (e.g. visual, fine, and gross motor coordination) revealed a similar outcome. our data suggest that while the NDE may be a valid and reliable test for the detection of general motor status, its use as a diagnostic/remedial tool for identifying motor ability is questionable. One of our recommendations is the consideration of a revised NDE in light of the current needs of clinicians and researchers.

  20. A real-time loop-mediated isothermal amplification assay for rapid detection of Shigella species.

    PubMed

    Liew, P S; Teh, C S J; Lau, Y L; Thong, K L

    2014-12-01

    Shigellosis is a foodborne illness caused by the genus Shigella and is an important global health issue. The development of effective techniques for rapid detection of this pathogen is essential for breaking the chain of transmission. Therefore, we have developed a novel loop-mediated isothermal amplification (LAMP) assay targeting the invasion plasmid antigen H (ipaH) gene to rapidly detect Shigella species. This assay could be performed in 90 min at an optimal temperature of 64ºC, with endpoint results visualized directly. Notably, the method was found to be more sensitive than conventional PCR. Indeed, the detection limit for the LAMP assay on pure bacterial cultures was 5.9 x 10(5) CFU/ml, while PCR displayed a limit of 5.9 x 10(7) CFU/ml. In spiked lettuce samples, the sensitivity of the LAMP assay was 3.6 x 10(4) CFU/g, whereas PCR was 3.6 x 10(5) CFU/g. Overall, the assay accurately identified 32 Shigella spp. with one enteroinvasive Escherichia coli displaying positive reaction while the remaining 32 non-Shigella strains tested were negative.

  1. Fully integrated lab-on-a-disc for nucleic acid analysis of food-borne pathogens.

    PubMed

    Kim, Tae-Hyeong; Park, Juhee; Kim, Chi-Ju; Cho, Yoon-Kyoung

    2014-04-15

    This paper describes a micro total analysis system for molecular analysis of Salmonella, a major food-borne pathogen. We developed a centrifugal microfluidic device, which integrated the three main steps of pathogen detection, DNA extraction, isothermal recombinase polymerase amplification (RPA), and detection, onto a single disc. A single laser diode was utilized for wireless control of valve actuation, cell lysis, and noncontact heating in the isothermal amplification step, thereby yielding a compact and miniaturized system. To achieve high detection sensitivity, rare cells in large volumes of phosphate-buffered saline (PBS) and milk samples were enriched before loading onto the disc by using antibody-coated magnetic beads. The entire procedure, from DNA extraction through to detection, was completed within 30 min in a fully automated fashion. The final detection was carried out using lateral flow strips by direct visual observation; detection limit was 10 cfu/mL and 10(2) cfu/mL in PBS and milk, respectively. Our device allows rapid molecular diagnostic analysis and does not require specially trained personnel or expensive equipment. Thus, we expect that it would have an array of potential applications, including in the detection of food-borne pathogens, environmental monitoring, and molecular diagnostics in resource-limited settings.

  2. Can biological motion research provide insight on how to reduce friendly fire incidents?

    PubMed

    Steel, Kylie A; Baxter, David; Dogramaci, Sera; Cobley, Stephen; Ellem, Eathan

    2016-10-01

    The ability to accurately detect, perceive, and recognize biological motion can be associated with a fundamental drive for survival, and it is a significant interest for perception researchers. This field examines various perceptual features of motion and has been assessed and applied in several real-world contexts (e.g., biometric, sport). Unexplored applications still exist however, including the military issue of friendly fire. There are many causes and processes leading to friendly fire and specific challenges that are associated with visual information extraction during engagement, such as brief glimpses, low acuity, camouflage, and uniform deception. Furthermore, visual information must often be processed under highly stressful (potentially threatening), time-constrained conditions that present a significant problem for soldiers. Biological motion research and anecdotal evidence from experienced combatants suggests that intentions, emotions, identities of human motion can be identified and discriminated, even when visual display is degraded or limited. Furthermore, research suggests that perceptual discriminatory capability of movement under visually constrained conditions is trainable. Therefore, given the limited military research linked to biological motion and friendly fire, an opportunity for cross-disciplinary investigations exists. The focus of this paper is twofold: first, to provide evidence for the possible link between biological motion factors and friendly fire, and second, to propose conceptual and methodological considerations and recommendations for perceptual-cognitive training within current military programs.

  3. Optical detection of blade flutter. [in YF-100 turbofan engine

    NASA Technical Reports Server (NTRS)

    Nieberding, W. C.; Pollack, J. L.

    1977-01-01

    The paper examines the capabilities of photoelectric scanning (PES) and stroboscopic imagery (SI) as optical monitoring tools for detection of the onset of flutter in the fan blades of an aircraft gas turbine engine. Both optical techniques give visual data in real time as well as video-tape records. PES is shown to be an ideal flutter monitor, since a single cathode ray tube displays the behavior of all the blades in a stage simultaneously. Operation of the SI system continuously while searching for a flutter condition imposes severe demands on the flash tube and affects its reliability, thus limiting its use as a flutter monitor. A better method of operation is to search for flutter with the PES and limit the use of SI to those times when the PES indicates interesting blade activity.

  4. Ultrafast electron microscopy integrated with a direct electron detection camera.

    PubMed

    Lee, Young Min; Kim, Young Jae; Kim, Ye-Jin; Kwon, Oh-Hoon

    2017-07-01

    In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM), which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  5. A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Kyung oh; Biomedical Sciences, Seoul National University College of Medicine; Cancer Research Institute, Seoul National University College of Medicine

    Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescencemore » signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.« less

  6. The Effects of Similarity on High-Level Visual Working Memory Processing.

    PubMed

    Yang, Li; Mo, Lei

    2017-01-01

    Similarity has been observed to have opposite effects on visual working memory (VWM) for complex images. How can these discrepant results be reconciled? To answer this question, we used a change-detection paradigm to test visual working memory performance for multiple real-world objects. We found that working memory for moderate similarity items was worse than that for either high or low similarity items. This pattern was unaffected by manipulations of stimulus type (faces vs. scenes), encoding duration (limited vs. self-paced), and presentation format (simultaneous vs. sequential). We also found that the similarity effects differed in strength in different categories (scenes vs. faces). These results suggest that complex real-world objects are represented using a centre-surround inhibition organization . These results support the category-specific cortical resource theory and further suggest that centre-surround inhibition organization may differ by category.

  7. Gains following perceptual learning are closely linked to the initial visual acuity.

    PubMed

    Yehezkel, Oren; Sterkin, Anna; Lev, Maria; Levi, Dennis M; Polat, Uri

    2016-04-28

    The goal of the present study was to evaluate the dependence of perceptual learning gains on initial visual acuity (VA), in a large sample of subjects with a wide range of VAs. A large sample of normally sighted and presbyopic subjects (N = 119; aged 40 to 63) with a wide range of uncorrected near visual acuities (VA, -0.12 to 0.8 LogMAR), underwent perceptual learning. Training consisted of detecting briefly presented Gabor stimuli under spatial and temporal masking conditions. Consistent with previous findings, perceptual learning induced a significant improvement in near VA and reading speed under conditions of limited exposure duration. Our results show that the improvements in VA and reading speed observed following perceptual learning are closely linked to the initial VA, with only a minor fraction of the observed improvement that may be attributed to the additional sessions performed by those with the worse VA.

  8. Visual short-term memory load reduces retinotopic cortex response to contrast.

    PubMed

    Konstantinou, Nikos; Bahrami, Bahador; Rees, Geraint; Lavie, Nilli

    2012-11-01

    Load Theory of attention suggests that high perceptual load in a task leads to reduced sensory visual cortex response to task-unrelated stimuli resulting in "load-induced blindness" [e.g., Lavie, N. Attention, distraction and cognitive control under load. Current Directions in Psychological Science, 19, 143-148, 2010; Lavie, N. Distracted and confused?: Selective attention under load. Trends in Cognitive Sciences, 9, 75-82, 2005]. Consideration of the findings that visual STM (VSTM) involves sensory recruitment [e.g., Pasternak, T., & Greenlee, M. Working memory in primate sensory systems. Nature Reviews Neuroscience, 6, 97-107, 2005] within Load Theory led us to a new hypothesis regarding the effects of VSTM load on visual processing. If VSTM load draws on sensory visual capacity, then similar to perceptual load, high VSTM load should also reduce visual cortex response to incoming stimuli leading to a failure to detect them. We tested this hypothesis with fMRI and behavioral measures of visual detection sensitivity. Participants detected the presence of a contrast increment during the maintenance delay in a VSTM task requiring maintenance of color and position. Increased VSTM load (manipulated by increased set size) led to reduced retinotopic visual cortex (V1-V3) responses to contrast as well as reduced detection sensitivity, as we predicted. Additional visual detection experiments established a clear tradeoff between the amount of information maintained in VSTM and detection sensitivity, while ruling out alternative accounts for the effects of VSTM load in terms of differential spatial allocation strategies or task difficulty. These findings extend Load Theory to demonstrate a new form of competitive interactions between early visual cortex processing and visual representations held in memory under load and provide a novel line of support for the sensory recruitment hypothesis of VSTM.

  9. Effects of visual attention on chromatic and achromatic detection sensitivities.

    PubMed

    Uchikawa, Keiji; Sato, Masayuki; Kuwamura, Keiko

    2014-05-01

    Visual attention has a significant effect on various visual functions, such as response time, detection and discrimination sensitivity, and color appearance. It has been suggested that visual attention may affect visual functions in the early visual pathways. In this study we examined selective effects of visual attention on sensitivities of the chromatic and achromatic pathways to clarify whether visual attention modifies responses in the early visual system. We used a dual task paradigm in which the observer detected a peripheral test stimulus presented at 4 deg eccentricities while the observer concurrently carried out an attention task in the central visual field. In experiment 1, it was confirmed that peripheral spectral sensitivities were reduced more for short and long wavelengths than for middle wavelengths with the central attention task so that the spectral sensitivity function changed its shape by visual attention. This indicated that visual attention affected the chromatic response more strongly than the achromatic response. In experiment 2 it was obtained that the detection thresholds increased in greater degrees in the red-green and yellow-blue chromatic directions than in the white-black achromatic direction in the dual task condition. In experiment 3 we showed that the peripheral threshold elevations depended on the combination of color-directions of the central and peripheral stimuli. Since the chromatic and achromatic responses were separately processed in the early visual pathways, the present results provided additional evidence that visual attention affects responses in the early visual pathways.

  10. Multifrequency survey of the intergalactic cloud in the M96 group

    NASA Technical Reports Server (NTRS)

    Schneider, Stephen E.; Skrutskie, M. F.; Hacking, Perry B.; Young, Judith S.; Dickman, Robert L.

    1989-01-01

    The intergalactic cloud of neutral hydrogen in the M96 group are examined for signs of emission over a wide range of frequencies, from radio waves to X rays. Past or present stellar activity in the gas might have been expected to produce detectable visual infrared, CO, OH, or radio recombination-line emission. None was detected. The limits are used to study physical conditions in the intergalactic gas. In particular, B and V band limits on starlight and IRAS limits on the presence of dust strongly constrain the presence of stars or stellar by-products. However, given the uncertainties about physical conditions in the intergalactic environment, it is difficult to rule out entirely the presence of stellar-processed materials. Results of neutral hydrogen mapping from a large-scale survey of the intergalactic cloud and surrounding region are also presented. These observations confirm that the gas is confined to a large ringlike structure. The simplest interpretation remains that the intergalactic gas in Leo is primordial.

  11. Development and comparison of immunochromatographic strips with three nanomaterial labels: Colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon for visual detection of salbutamol.

    PubMed

    Liu, Bing; Wang, Lingling; Tong, Bei; Zhang, Yan; Sheng, Wei; Pan, Mingfei; Wang, Shuo

    2016-11-15

    In this study, the three nanomaterials: colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon were respectively labeled with the antibody against salbutamol (SAL). We aimed to develop immunochromatographic strips with these nanomaterial labels and determine their performance in visual detection of SAL. For the colloidal gold-based strip, the detection limit of SAL was 1.0µgL(-1) in standard solution and 5.0µgkg(-1) in meat samples. For the GPG- and colloidal carbon-based strips, the limit of detection was 2.0µgL(-1) in standard solution and 10µgkg(-1) in meat samples. The results obtained using the test strips were found to be highly consistent with those obtained using a commercial kit, indicating the high accuracy of these strips. The three strips were also found to be stable up to 18 weeks under laboratory conditions. In terms of sensitivity, the colloidal gold-based strip was slightly better than the other two. For the GPG- and colloidal carbon-based strips, the difference between the results obtained for different batches was small (high consistency), and the stability was much better than that of the colloidal gold-based one. Our results indicate that colloidal carbon can be used as a label in immunochromatographic tests; it can also help reduce the cost involved and scale-up the production. The use of immunochromatographic test strips labeled with colloidal carbon can be a rapid and inexpensive method for SAL assays in on-site applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii.

    PubMed

    Chen, Hua-Wei; Ching, Wei-Mei

    2016-04-18

    Coxiella burnetii, the agent causing Q fever, is an obligate intracellular bacterium. PCR based diagnostic assays have been developed for detecting C. burnetii DNA in cell cultures and clinical samples. PCR requires specialized equipment and extensive end user training, and therefore, it is not suitable for routine work especially in a resource-constrained area. We have developed a loop-mediated isothermal amplification (LAMP) assay to detect the presence of C. burnetii in patient samples. This method is performed at a single temperature around 60 °C in a water bath or heating block. The sensitivity of this LAMP assay is very similar to PCR with a detection limit of about 25 copies per reaction. This report describes the preparation of the reaction using lyophilized reagents and visualization of results using hydroxynaphthol blue (HNB) or a UV lamp with fluorescent intercalating dye in the reaction. The LAMP reagents were lyophilized and stored at room temperature (RT) for one month without loss of detection sensitivity. This LAMP assay is particularly robust because the reaction mixture preparation does not involve complex steps. This method is ideal for use in resource-limited settings where Q fever is endemic.

  13. Relative saliency in change signals affects perceptual comparison and decision processes in change detection.

    PubMed

    Yang, Cheng-Ta

    2011-12-01

    Change detection requires perceptual comparison and decision processes on different features of multiattribute objects. How relative salience between two feature-changes influences the processes has not been addressed. This study used the systems factorial technology to investigate the processes when detecting changes in a Gabor patch with visual inputs from orientation and spatial frequency channels. Two feature-changes were equally salient in Experiment 1, but a frequency-change was more salient than an orientation-change in Experiment 2. Results showed that all four observers adopted parallel self-terminating processing with limited- to unlimited-capacity processing in Experiment 1. In Experiment 2, one observer used parallel self-terminating processing with unlimited-capacity processing, and the others adopted serial self-terminating processing with limited- to unlimited-capacity processing to detect changes. Postexperimental interview revealed that subjective utility of feature information underlay the adoption of a decision strategy. These results highlight that observers alter decision strategies in change detection depending on the relative saliency in change signals, with relative saliency being determined by both physical salience and subjective weight of feature information. When relative salience exists, individual differences in the process characteristics emerge.

  14. The rainfall plot: its motivation, characteristics and pitfalls.

    PubMed

    Domanska, Diana; Vodák, Daniel; Lund-Andersen, Christin; Salvatore, Stefania; Hovig, Eivind; Sandve, Geir Kjetil

    2017-05-18

    A visualization referred to as rainfall plot has recently gained popularity in genome data analysis. The plot is mostly used for illustrating the distribution of somatic cancer mutations along a reference genome, typically aiming to identify mutation hotspots. In general terms, the rainfall plot can be seen as a scatter plot showing the location of events on the x-axis versus the distance between consecutive events on the y-axis. Despite its frequent use, the motivation for applying this particular visualization and the appropriateness of its usage have never been critically addressed in detail. We show that the rainfall plot allows visual detection even for events occurring at high frequency over very short distances. In addition, event clustering at multiple scales may be detected as distinct horizontal bands in rainfall plots. At the same time, due to the limited size of standard figures, rainfall plots might suffer from inability to distinguish overlapping events, especially when multiple datasets are plotted in the same figure. We demonstrate the consequences of plot congestion, which results in obscured visual data interpretations. This work provides the first comprehensive survey of the characteristics and proper usage of rainfall plots. We find that the rainfall plot is able to convey a large amount of information without any need for parameterization or tuning. However, we also demonstrate how plot congestion and the use of a logarithmic y-axis may result in obscured visual data interpretations. To aid the productive utilization of rainfall plots, we demonstrate their characteristics and potential pitfalls using both simulated and real data, and provide a set of practical guidelines for their proper interpretation and usage.

  15. Activity-dependent regulation of NMDAR1 immunoreactivity in the developing visual cortex.

    PubMed

    Catalano, S M; Chang, C K; Shatz, C J

    1997-11-01

    NMDA receptors have been implicated in activity-dependent synaptic plasticity in the developing visual cortex. We examined the distribution of immunocytochemically detectable NMDAR1 in visual cortex of cats and ferrets from late embryonic ages to adulthood. Cortical neurons are initially highly immunostained. This level declines gradually over development, with the notable exception of cortical layers 2/3, where levels of NMDAR1 immunostaining remain high into adulthood. Within layer 4, the decline in NMDAR1 immunostaining to adult levels coincides with the completion of ocular dominance column formation and the end of the critical period for layer 4. To determine whether NMDAR1 immunoreactivity is regulated by retinal activity, animals were dark-reared or retinal activity was completely blocked in one eye with tetrodotoxin (TTX). Dark-rearing does not cause detectable changes in NMDAR1 immunoreactivity. However, 2 weeks of monocular TTX administration decreases NMDAR1 immunoreactivity in layer 4 of the columns of the blocked eye. Thus, high levels of NMDAR1 immunostaining within the visual cortex are temporally correlated with ocular dominance column formation and developmental plasticity; the persistence of staining in layers 2/3 also correlates with the physiological plasticity present in these layers in the adult. In addition, visual experience is not required for the developmental changes in the laminar pattern of NMDAR1 levels, but the presence of high levels of NMDAR1 in layer 4 during the critical period does require retinal activity. These observations are consistent with a central role for NMDA receptors in promoting and ultimately limiting synaptic rearrangements in the developing neocortex.

  16. Left-lateralized N170 Effects of Visual Expertise in Reading: Evidence from Japanese Syllabic and Logographic Scripts

    PubMed Central

    Maurer, Urs; Zevin, Jason D.; McCandliss, Bruce D.

    2015-01-01

    The N170 component of the event-related potential (ERP) reflects experience-dependent neural changes in several forms of visual expertise, including expertise for visual words. Readers skilled in writing systems that link characters to phonemes (i.e., alphabetic writing) typically produce a left-lateralized N170 to visual word forms. This study examined the N170 in three Japanese scripts that link characters to larger phonological units. Participants were monolingual English speakers (EL1) and native Japanese speakers (JL1) who were also proficient in English. ERPs were collected using a 129-channel array, as participants performed a series of experiments viewing words or novel control stimuli in a repetition detection task. The N170 was strongly left-lateralized for all three Japanese scripts (including logographic Kanji characters) in JL1 participants, but bilateral in EL1 participants viewing these same stimuli. This demonstrates that left-lateralization of the N170 is dependent on specific reading expertise and is not limited to alphabetic scripts. Additional contrasts within the moraic Katakana script revealed equivalent N170 responses in JL1 speakers for familiar Katakana words and for Kanji words transcribed into novel Katakana words, suggesting that the N170 expertise effect is driven by script familiarity rather than familiarity with particular visual word forms. Finally, for English words and novel symbol string stimuli, both EL1 and JL1 subjects produced equivalent responses for the novel symbols, and more left-lateralized N170 responses for the English words, indicating that such effects are not limited to the first language. Taken together, these cross-linguistic results suggest that similar neural processes underlie visual expertise for print in very different writing systems. PMID:18370600

  17. High-frequency spectral ultrasound imaging (SUSI) visualizes early post-traumatic heterotopic ossification (HO) in a mouse model.

    PubMed

    Ranganathan, Kavitha; Hong, Xiaowei; Cholok, David; Habbouche, Joe; Priest, Caitlin; Breuler, Christopher; Chung, Michael; Li, John; Kaura, Arminder; Hsieh, Hsiao Hsin Sung; Butts, Jonathan; Ucer, Serra; Schwartz, Ean; Buchman, Steven R; Stegemann, Jan P; Deng, Cheri X; Levi, Benjamin

    2018-04-01

    Early treatment of heterotopic ossification (HO) is currently limited by delayed diagnosis due to limited visualization at early time points. In this study, we validate the use of spectral ultrasound imaging (SUSI) in an animal model to detect HO as early as one week after burn tenotomy. Concurrent SUSI, micro CT, and histology at 1, 2, 4, and 9weeks post-injury were used to follow the progression of HO after an Achilles tenotomy and 30% total body surface area burn (n=3-5 limbs per time point). To compare the use of SUSI in different types of injury models, mice (n=5 per group) underwent either burn/tenotomy or skin incision injury and were imaged using a 55MHz probe on VisualSonics VEVO 770 system at one week post injury to evaluate the ability of SUSI to distinguish between edema and HO. Average acoustic concentration (AAC) and average scatterer diameter (ASD) were calculated for each ultrasound image frame. Micro CT was used to calculate the total volume of HO. Histology was used to confirm bone formation. Using SUSI, HO was visualized as early as 1week after injury. HO was visualized earliest by 4weeks after injury by micro CT. The average acoustic concentration of HO was 33% more than that of the control limb (n=5). Spectroscopic foci of HO present at 1week that persisted throughout all time points correlated with the HO present at 9weeks on micro CT imaging. SUSI visualizes HO as early as one week after injury in an animal model. SUSI represents a new imaging modality with promise for early diagnosis of HO. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Endoscopic innovations to increase the adenoma detection rate during colonoscopy

    PubMed Central

    Dik, Vincent K; Moons, Leon MG; Siersema, Peter D

    2014-01-01

    Up to a quarter of polyps and adenomas are missed during colonoscopy due to poor visualization behind folds and the inner curves of flexures, and the presence of flat lesions that are difficult to detect. These numbers may however be conservative because they mainly come from back-to-back studies performed with standard colonoscopes, which are unable to visualize the entire mucosal surface. In the past several years, new endoscopic techniques have been introduced to improve the detection of polyps and adenomas. The introduction of high definition colonoscopes and visual image enhancement technologies have been suggested to lead to better recognition of flat and small lesions, but the absolute increase in diagnostic yield seems limited. Cap assisted colonoscopy and water-exchange colonoscopy are methods to facilitate cecal intubation and increase patients comfort, but show only a marginal or no benefit on polyp and adenoma detection. Retroflexion is routinely used in the rectum for the inspection of the dentate line, but withdrawal in retroflexion in the colon is in general not recommended due to the risk of perforation. In contrast, colonoscopy with the Third-Eye Retroscope® may result in considerable lower miss rates compared to standard colonoscopy, but this technique is not practical in case of polypectomy and is more time consuming. The recently introduced Full Spectrum Endoscopy™ colonoscopes maintains the technical capabilities of standard colonoscopes and provides a much wider view of 330 degrees compared to the 170 degrees with standard colonoscopes. Remarkable lower adenoma miss rates with this new technique were recently demonstrated in the first randomized study. Nonetheless, more studies are required to determine the exact additional diagnostic yield in clinical practice. Optimizing the efficacy of colorectal cancer screening and surveillance requires high definition colonoscopes with improved virtual chromoendoscopy technology that visualize the whole colon mucosa while maintaining optimal washing, suction and therapeutic capabilities, and keeping the procedural time as low and patient discomfort as optimal as possible. PMID:24605019

  19. Highly selective visual monitoring of hazardous fluoride ion in aqueous media using thiobarbituric-capped gold nanoparticles.

    PubMed

    Boken, Jyoti; Thatai, Sheenam; Khurana, Parul; Prasad, Surendra; Kumar, Dinesh

    2015-01-01

    The rapid, selective and sensitive measurement and monitoring of hazardous materials as analytes are the central themes in the development of any successful analytical technique. With this aim, we have synthesized the thiobarbituric-capped gold nanoparticles (TBA-capped Au NPs) involving chemical reduction of HAuCl4 using 2-thiobarbituric acid (TBA) as a reducing and capping agent. The morphology of the TBA-capped Au NPs was confirmed using transmission electron microscope images. For the first time this article reports that the developed TAB-capped Au NPs displays selective, ultrafast and sensitive colorimetric detection of fluoride ion in aqueous samples. The detection of fluoride ion was confirmed by the disappearance of the localized surface plasmon resonance (LSPR) band at 554 nm using UV-vis spectroscopy. The interaction of F(-) with TBA-capped Au NPs in aqueous solution has also been confirmed by Raman and FTIR spectroscopy. One of the most exciting accomplishments is the visual detection limit for fluoride ion has been found to be 10 mM at commonly acceptable water pH range 7-8. The whole detection procedure takes not more than 40s with excellent selectivity providing sample throughput of more than 60 per hour. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Preparation of an Efficient Ratiometric Fluorescent Nanoprobe (m-CDs@[Ru(bpy)3]2+) for Visual and Specific Detection of Hypochlorite on Site and in Living Cells.

    PubMed

    Zhan, Yuanjin; Luo, Fang; Guo, Longhua; Qiu, Bin; Lin, Yuhong; Li, Juan; Chen, Guonan; Lin, Zhenyu

    2017-11-22

    Hypochlorite (ClO - ) is one of the most important reactive oxygen species (ROS), which plays an important role in sustaining human innate immunity during microbial invasion. Moreover, ClO - is a powerful oxidizer for water treatment. The safety of drinking water is closely related to its content. Herein, m-phenylenediamine (mPD) is used as a precursor to prepare carbon dots (named m-CDs) with highly fluorescent quantum yield (31.58% in water), and our investigation shows that the strong fluorescent emission of m-CDs can be effectively quenched by ClO - . Based on these findings, we developed a novel fluorescent nanoprobe (m-CDs) for highly selective detection of ClO - . The linear range was from 0.05 to 7 μM (R 2 = 0.998), and the limit of detection (S/N = 3) was as low as 0.012 μM. Moreover, a portable agarose hydrogel solid matrix-based ratiometric fluorescent nanoprobe (m-CDs@[Ru(bpy) 3 ] 2+ ) sensor was subsequently developed for visual on-site detection of ClO - with the naked eyes under a UV lamp, suggesting its potential in practical application with low cost and excellent performance in water quality monitoring. Additionally, intracellular detection of exogenous ClO - was demonstrated via ratiometric imaging microscopy.

  1. Automated visual inspection of brake shoe wear

    NASA Astrophysics Data System (ADS)

    Lu, Shengfang; Liu, Zhen; Nan, Guo; Zhang, Guangjun

    2015-10-01

    With the rapid development of high-speed railway, the automated fault inspection is necessary to ensure train's operation safety. Visual technology is paid more attention in trouble detection and maintenance. For a linear CCD camera, Image alignment is the first step in fault detection. To increase the speed of image processing, an improved scale invariant feature transform (SIFT) method is presented. The image is divided into multiple levels of different resolution. Then, we do not stop to extract the feature from the lowest resolution to the highest level until we get sufficient SIFT key points. At that level, the image is registered and aligned quickly. In the stage of inspection, we devote our efforts to finding the trouble of brake shoe, which is one of the key components in brake system on electrical multiple units train (EMU). Its pre-warning on wear limitation is very important in fault detection. In this paper, we propose an automatic inspection approach to detect the fault of brake shoe. Firstly, we use multi-resolution pyramid template matching technology to fast locate the brake shoe. Then, we employ Hough transform to detect the circles of bolts in brake region. Due to the rigid characteristic of structure, we can identify whether the brake shoe has a fault. The experiments demonstrate that the way we propose has a good performance, and can meet the need of practical applications.

  2. Visual Non-Instrumental On-Site Detection of Fumonisin B1, B2, and B3 in Cereal Samples Using a Clean-Up Combined with Gel-Based Immunoaffinity Test Column Assay

    PubMed Central

    Wu, Hesen; Ji, Weihong; Li, Zhi; Chu, Fangyu; Wang, Shuo

    2018-01-01

    A visual immunoaffinity test column (IATC) assay was developed to detect fumonisins in cereal samples for spot tests without the need for special instruments. The developed IATC assay had equivalent recognition capability for fumonisin B1 (FB1), fumonisin B2 (FB2), or fumonisin B3 (FB3), and exhibited no cross-reactivity with aflatoxin B1, ochratoxin A, zearalenone, or the T-2 toxin. The sample pretreatment was accomplished more rapidly and with greater ease, the entire assay procedure was completed in approximately 10 min, including sample pretreatment and testing. The limits of detection (LODs) of the IATC assay to detect fumonisins in the maize, barley, oat, and millet samples were 20 μg kg−1. The results of the spiked maize, barley, oat, and millet and real maize samples by the IATC assay agreed well with the results obtained by the commercial fumonisin enzyme-linked immunosorbent assay (ELISA) test kit and liquid chromatography-tandem mass spectrometry (LC-MS/MS), respectively. The developed IATC assay can serve as a useful screening tool for the rapid, qualitative, and semi-quantitative detection of the total content of fumonisins (sum of FB1, FB2, and FB3) in cereal samples on-site. PMID:29671825

  3. Rapid visual detection of cyprinid herpesvirus 2 by recombinase polymerase amplification combined with a lateral flow dipstick.

    PubMed

    Wang, H; Sun, M; Xu, D; Podok, P; Xie, J; Jiang, Ys; Lu, Lq

    2018-05-28

    Herpesviral haematopoietic necrosis (HVHN), caused by cyprinid herpesvirus 2 (CyHV-2), causes significant losses in crucian carp (Carassius carassius) aquaculture. Rapid and convenient DNA assay detection of CyHV-2 is useful for field diagnosis. Recombinase polymerase amplification (RPA) is a novel isothermal DNA amplification and detection technology that can amplify DNA within 30 min at ~37°C by simulating in vivo DNA recombination. Herein, a rapid and convenient detection assay based on RPA with a lateral flow dipstick (LFD) was developed for detecting CyHV-2. The highly conserved ORF72 of CyHV-2 was targeted by specific and sensitive primers and probes. The optimized assay takes only 15 min at 38°C using a water bath, with analysis of products by 2% agarose gel electrophoresis within 30 min. A simple lateral flow strip based on the unique probe in reaction buffer was developed for visualization. The entire RPA-LFD assay takes 50 min less than the routine PCR method, is 100 times more sensitive and displays no cross-reaction with other aquatic viruses. The combined isothermal RPA and lateral flow assay (RPA-LFD) provides a simple, rapid, reliable method that could improve field diagnosis of CyHV-2 when resources are limited. © 2018 John Wiley & Sons Ltd.

  4. Detection of emotional faces: salient physical features guide effective visual search.

    PubMed

    Calvo, Manuel G; Nummenmaa, Lauri

    2008-08-01

    In this study, the authors investigated how salient visual features capture attention and facilitate detection of emotional facial expressions. In a visual search task, a target emotional face (happy, disgusted, fearful, angry, sad, or surprised) was presented in an array of neutral faces. Faster detection of happy and, to a lesser extent, surprised and disgusted faces was found both under upright and inverted display conditions. Inversion slowed down the detection of these faces less than that of others (fearful, angry, and sad). Accordingly, the detection advantage involves processing of featural rather than configural information. The facial features responsible for the detection advantage are located in the mouth rather than the eye region. Computationally modeled visual saliency predicted both attentional orienting and detection. Saliency was greatest for the faces (happy) and regions (mouth) that were fixated earlier and detected faster, and there was close correspondence between the onset of the modeled saliency peak and the time at which observers initially fixated the faces. The authors conclude that visual saliency of specific facial features--especially the smiling mouth--is responsible for facilitated initial orienting, which thus shortens detection. (PsycINFO Database Record (c) 2008 APA, all rights reserved).

  5. Detection of Emotional Faces: Salient Physical Features Guide Effective Visual Search

    ERIC Educational Resources Information Center

    Calvo, Manuel G.; Nummenmaa, Lauri

    2008-01-01

    In this study, the authors investigated how salient visual features capture attention and facilitate detection of emotional facial expressions. In a visual search task, a target emotional face (happy, disgusted, fearful, angry, sad, or surprised) was presented in an array of neutral faces. Faster detection of happy and, to a lesser extent,…

  6. Association and comparison between visual inspection and bitewing radiography for the detection of recurrent dental caries under restorations.

    PubMed

    Lino, José R; Ramos-Jorge, Joana; Coelho, Valéria Silveira; Ramos-Jorge, Maria L; Moysés, Marcos R; Ribeiro, José C R

    2015-08-01

    The aim of the present study was to investigate, in posterior teeth, the association between the characteristics of the margins of a restoration visually inspected and the presence, under restorations, of recurrent or residual dental caries detected by radiographic examination. Furthermore, the agreement between visual inspection and radiographs to detect dental caries was assessed. Eighty-five permanent molars and premolars with resin restorations on the interproximal and/or occlusal faces, from 18 patients, were submitted for visual inspection and radiographic examination. The visual inspection involved the criteria of the International Caries Detection and Assessment System (ICDAS). Bitewing radiographs were used for the radiographic examination. Logistic regression was used to analyse the association between the characteristics of the margins of a restoration assessed by visual inspection (absence of dental caries, or early, established, inactive and active lesions) and the presence of recurrent caries detected by radiographs. Kappa coefficients were calculated for determining agreement between the two methods. The Kappa coefficient for agreement between visual inspection and radiographic examination was 0.19. Established lesions [odds ratio (OR) = 9.89; 95% confidence interval (95% CI): 2.94-33.25; P < 0.05] and lesion activity (OR = 2.57; 95% CI: 0.91-7.27; P < 0.05) detected by visual inspection, were associated with recurrent or residual dental caries detected by radiographs. Restorations with established and active lesions at the margins had a greater chance of exhibiting recurrent or residual lesions in the radiographic examination. The present findings demonstrate that restorations with established and active lesions at the margins when visually inspected often require removal and retreatment. © 2015 FDI World Dental Federation.

  7. A highly selective and fast-response fluorescent probe based on Cd-MOF for the visual detection of Al3+ ion and quantitative detection of Fe3+ ion

    NASA Astrophysics Data System (ADS)

    Lv, Rui; Chen, Zhihengyu; Fu, Xin; Yang, Boyi; Li, Hui; Su, Jian; Gu, Wen; Liu, Xin

    2018-03-01

    A new luminescent Cd(II)-based metal-organic framework, [Cd(PAM)(4-bpdb)1.5]·DMF (Cd-MOF, PAM = 4,4‧-methylenebis(3-hydroxy-2-naphthalene-carboxylic acid) and 4-bpdb = 1,4-bis(4-pyridyl)-2,3-diaza-1,3-butadiene) was successfully synthesized by solvothermal synthesis method. The Cd-MOF reveals excellent luminescence property which can selectively detect Al3+ and Fe3+ ions among other interfering metal ions. The detection limit is 0.56 μM for Al3+ ion in aqueous solutions, and it is obvious lower than the maximum standard of Al3+ ion in drinking water of 7.41 μM which is defined by the WHO. More importantly, the Cd-MOF shows an obvious luminescent color change from yellow to blue under the UV lamp irradiation at 365 nm with the dropping of Al3+ ion, which can make it apply to the visual detection. And, the detection based on the test paper was explored for the first time. In addition, the Cd-MOF can also be used for quantitative detecting Fe3+ ion, and the LOD for Fe3+ ion can be as low as 0.3 μM which is lower than most reported MOFs. It is worth noting that Fe3+ and Al3+ ions can not interfere with each other. These properties make it become an excellent luminescence sensor for the detection of Al3+ and Fe3+ ions.

  8. Collision Detection for Underwater ROV Manipulator Systems

    PubMed Central

    Rossi, Matija; Dooly, Gerard; Toal, Daniel

    2018-01-01

    Work-class ROVs equipped with robotic manipulators are extensively used for subsea intervention operations. Manipulators are teleoperated by human pilots relying on visual feedback from the worksite. Operating in a remote environment, with limited pilot perception and poor visibility, manipulator collisions which may cause significant damage are likely to happen. This paper presents a real-time collision detection algorithm for marine robotic manipulation. The proposed collision detection mechanism is developed, integrated into a commercial ROV manipulator control system, and successfully evaluated in simulations and experimental setup using a real industry standard underwater manipulator. The presented collision sensing solution has a potential to be a useful pilot assisting tool that can reduce the task load, operational time, and costs of subsea inspection, repair, and maintenance operations. PMID:29642396

  9. Collision Detection for Underwater ROV Manipulator Systems.

    PubMed

    Sivčev, Satja; Rossi, Matija; Coleman, Joseph; Omerdić, Edin; Dooly, Gerard; Toal, Daniel

    2018-04-06

    Work-class ROVs equipped with robotic manipulators are extensively used for subsea intervention operations. Manipulators are teleoperated by human pilots relying on visual feedback from the worksite. Operating in a remote environment, with limited pilot perception and poor visibility, manipulator collisions which may cause significant damage are likely to happen. This paper presents a real-time collision detection algorithm for marine robotic manipulation. The proposed collision detection mechanism is developed, integrated into a commercial ROV manipulator control system, and successfully evaluated in simulations and experimental setup using a real industry standard underwater manipulator. The presented collision sensing solution has a potential to be a useful pilot assisting tool that can reduce the task load, operational time, and costs of subsea inspection, repair, and maintenance operations.

  10. The Phosphorylation State of the Drosophila TRP Channel Modulates the Frequency Response to Oscillating Light In Vivo

    PubMed Central

    Rhodes-Mordov, Elisheva; Katz, Ben; Oberegelsbacher, Claudia; Yasin, Bushra; Tzadok, Hanan; Huber, Armin

    2017-01-01

    Drosophila photoreceptors respond to oscillating light of high frequency (∼100 Hz), while the detected maximal frequency is modulated by the light rearing conditions, thus enabling high sensitivity to light and high temporal resolution. However, the molecular basis for this adaptive process is unclear. Here, we report that dephosphorylation of the light-activated transient receptor potential (TRP) ion channel at S936 is a fast, graded, light-dependent, and Ca2+-dependent process that is partially modulated by the rhodopsin phosphatase retinal degeneration C (RDGC). Electroretinogram measurements of the frequency response to oscillating lights in vivo revealed that dark-reared flies expressing wild-type TRP exhibited a detection limit of oscillating light at relatively low frequencies, which was shifted to higher frequencies upon light adaptation. Strikingly, preventing phosphorylation of the S936-TRP site by alanine substitution in transgenic Drosophila (trpS936A) abolished the difference in frequency response between dark-adapted and light-adapted flies, resulting in high-frequency response also in dark-adapted flies. In contrast, inserting a phosphomimetic mutation by substituting the S936-TRP site to aspartic acid (trpS936D) set the frequency response of light-adapted flies to low frequencies typical of dark-adapted flies. Light-adapted rdgC mutant flies showed relatively high S936-TRP phosphorylation levels and light–dark phosphorylation dynamics. These findings suggest that RDGC is one but not the only phosphatase involved in pS936-TRP dephosphorylation. Together, this study indicates that TRP channel dephosphorylation is a regulatory process that affects the detection limit of oscillating light according to the light rearing condition, thus adjusting dynamic processing of visual information under varying light conditions. SIGNIFICANCE STATEMENT Drosophila photoreceptors exhibit high temporal resolution as manifested in frequency response to oscillating light of high frequency (≤∼100 Hz). Light rearing conditions modulate the maximal frequency detected by photoreceptors, thus enabling them to maintain high sensitivity to light and high temporal resolution. However, the precise mechanisms for this process are not fully understood. Here, we show by combination of biochemistry and in vivo electrophysiology that transient receptor potential (TRP) channel dephosphorylation at a specific site is a fast, light-activated and Ca2+-dependent regulatory process. TRP dephosphorylation affects the detection limit of oscillating light according to the adaptation state of the photoreceptor cells by shifting the detection limit to higher frequencies upon light adaptation. This novel mechanism thus adjusts dynamic processing of visual information under varying light conditions. PMID:28314815

  11. Investigation of the sensitivity of a cross-polarized light visualization system to detect subclinical erythema and dryness in women with vulvovaginitis.

    PubMed

    Farage, Miranda A; Singh, Mukul; Ledger, William J

    2009-07-01

    An enhanced visualization technique using polarized light (Syris v600 enhanced visualization system; Syris Scientific LLC, Gray, ME) detects surface and subsurface ( approximately 1 mm depth) inflammation. We sought to compare the Syris v600 system with unaided visual inspection and colposcopy of the female genitalia. Erythema and dryness of the vulva, introitus, vagina, and cervix were visualized and scored by each method in patients with and without vulvitis. Subsurface visualization was more sensitive in detecting genital erythema and dryness at all sites whether or not symptoms were present. Subsurface inflammation of the introitus, vagina, and cervix only was detected uniquely in women with vulvar vestibulitis syndrome (VVS). A subset of women presenting with VVS exhibited subclinical inflammation of the vulva vestibule and vagina (designated VVS/lichen sclerosus subgroup). Enhanced visualization of the genital epithelial subsurface with cross-polarized light may assist in diagnosing subclinical inflammation in vulvar conditions heretofore characterized as sensory syndromes.

  12. Lowering thresholds for speed limit enforcement impairs peripheral object detection and increases driver subjective workload.

    PubMed

    Bowden, Vanessa K; Loft, Shayne; Tatasciore, Monica; Visser, Troy A W

    2017-01-01

    Speed enforcement reduces incidences of speeding, thus reducing traffic accidents. Accordingly, it has been argued that stricter speed enforcement thresholds could further improve road safety. Effective speed monitoring however requires driver attention and effort, and human information-processing capacity is limited. Emphasizing speed monitoring may therefore reduce resource availability for other aspects of safe vehicle operation. We investigated whether lowering enforcement thresholds in a simulator setting would introduce further competition for limited cognitive and visual resources. Eighty-four young adult participants drove under conditions where they could be fined for travelling 1, 6, or 11km/h over a 50km/h speed-limit. Stricter speed enforcement led to greater subjective workload and significant decrements in peripheral object detection. These data indicate that the benefits of reduced speeding with stricter enforcement may be at least partially offset by greater mental demands on drivers, reducing their responses to safety-critical stimuli on the road. It is likely these results under-estimate the impact of stricter speed enforcement on real-world drivers who experience significantly greater pressures to drive at or above the speed limit. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Rendering visual events as sounds: Spatial attention capture by auditory augmented reality.

    PubMed

    Stone, Scott A; Tata, Matthew S

    2017-01-01

    Many salient visual events tend to coincide with auditory events, such as seeing and hearing a car pass by. Information from the visual and auditory senses can be used to create a stable percept of the stimulus. Having access to related coincident visual and auditory information can help for spatial tasks such as localization. However not all visual information has analogous auditory percepts, such as viewing a computer monitor. Here, we describe a system capable of detecting and augmenting visual salient events into localizable auditory events. The system uses a neuromorphic camera (DAVIS 240B) to detect logarithmic changes of brightness intensity in the scene, which can be interpreted as salient visual events. Participants were blindfolded and asked to use the device to detect new objects in the scene, as well as determine direction of motion for a moving visual object. Results suggest the system is robust enough to allow for the simple detection of new salient stimuli, as well accurately encoding direction of visual motion. Future successes are probable as neuromorphic devices are likely to become faster and smaller in the future, making this system much more feasible.

  14. Rendering visual events as sounds: Spatial attention capture by auditory augmented reality

    PubMed Central

    Tata, Matthew S.

    2017-01-01

    Many salient visual events tend to coincide with auditory events, such as seeing and hearing a car pass by. Information from the visual and auditory senses can be used to create a stable percept of the stimulus. Having access to related coincident visual and auditory information can help for spatial tasks such as localization. However not all visual information has analogous auditory percepts, such as viewing a computer monitor. Here, we describe a system capable of detecting and augmenting visual salient events into localizable auditory events. The system uses a neuromorphic camera (DAVIS 240B) to detect logarithmic changes of brightness intensity in the scene, which can be interpreted as salient visual events. Participants were blindfolded and asked to use the device to detect new objects in the scene, as well as determine direction of motion for a moving visual object. Results suggest the system is robust enough to allow for the simple detection of new salient stimuli, as well accurately encoding direction of visual motion. Future successes are probable as neuromorphic devices are likely to become faster and smaller in the future, making this system much more feasible. PMID:28792518

  15. What You Don't Notice Can Harm You: Age-Related Differences in Detecting Concurrent Visual, Auditory, and Tactile Cues.

    PubMed

    Pitts, Brandon J; Sarter, Nadine

    2018-06-01

    Objective This research sought to determine whether people can perceive and process three nonredundant (and unrelated) signals in vision, hearing, and touch at the same time and how aging and concurrent task demands affect this ability. Background Multimodal displays have been shown to improve multitasking and attention management; however, their potential limitations are not well understood. The majority of studies on multimodal information presentation have focused on the processing of only two concurrent and, most often, redundant cues by younger participants. Method Two experiments were conducted in which younger and older adults detected and responded to a series of singles, pairs, and triplets of visual, auditory, and tactile cues in the absence (Experiment 1) and presence (Experiment 2) of an ongoing simulated driving task. Detection rates, response times, and driving task performance were measured. Results Compared to younger participants, older adults showed longer response times and higher error rates in response to cues/cue combinations. Older participants often missed the tactile cue when three cues were combined. They sometimes falsely reported the presence of a visual cue when presented with a pair of auditory and tactile signals. Driving performance suffered most in the presence of cue triplets. Conclusion People are more likely to miss information if more than two concurrent nonredundant signals are presented to different sensory channels. Application The findings from this work help inform the design of multimodal displays and ensure their usefulness across different age groups and in various application domains.

  16. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    PubMed

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green-Labeled Podoplanin Antibody.

    PubMed

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.

  18. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green–Labeled Podoplanin Antibody

    PubMed Central

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)–labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma–xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression–dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings. PMID:29649929

  19. A Novel "Off-On" Fluorescent Probe Based on Carbon Nitride Nanoribbons for the Detection of Citrate Anion and Live Cell Imaging.

    PubMed

    Hu, Yanling; Yang, Donlgliang; Yang, Chen; Feng, Ning; Shao, Zhouwei; Zhang, Lei; Wang, Xiaodong; Weng, Lixing; Luo, Zhimin; Wang, Lianhui

    2018-04-11

    A novel fluorescent "off-on" probe based on carbon nitride (C₃N₄) nanoribbons was developed for citrate anion (C₆H₅O₇ 3- ) detection. The fluorescence of C₃N₄ nanoribbons can be quenched by Cu 2+ and then recovered by the addition of C₆H₅O₇ 3- , because the chelation between C₆H₅O₇ 3- and Cu 2+ blocks the electron transfer between Cu 2+ and C₃N₄ nanoribbons. The turn-on fluorescent sensor using this fluorescent "off-on" probe can detect C₆H₅O₇ 3- rapidly and selectively, showing a wide detection linear range (1~400 μM) and a low detection limit (0.78 μM) in aqueous solutions. Importantly, this C₃N₄ nanoribbon-based "off-on" probe exhibits good biocompatibility and can be used as fluorescent visualizer for exogenous C₆H₅O₇ 3- in HeLa cells.

  20. Sensitive, fast, and specific immunoassays for methyltestosterone detection.

    PubMed

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-04-29

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%-100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  1. A habituation based approach for detection of visual changes in surveillance camera

    NASA Astrophysics Data System (ADS)

    Sha'abani, M. N. A. H.; Adan, N. F.; Sabani, M. S. M.; Abdullah, F.; Nadira, J. H. S.; Yasin, M. S. M.

    2017-09-01

    This paper investigates a habituation based approach in detecting visual changes using video surveillance systems in a passive environment. Various techniques have been introduced for dynamic environment such as motion detection, object classification and behaviour analysis. However, in a passive environment, most of the scenes recorded by the surveillance system are normal. Therefore, implementing a complex analysis all the time in the passive environment resulting on computationally expensive, especially when using a high video resolution. Thus, a mechanism of attention is required, where the system only responds to an abnormal event. This paper proposed a novelty detection mechanism in detecting visual changes and a habituation based approach to measure the level of novelty. The objective of the paper is to investigate the feasibility of the habituation based approach in detecting visual changes. Experiment results show that the approach are able to accurately detect the presence of novelty as deviations from the learned knowledge.

  2. Traffic Sign Detection Based on Biologically Visual Mechanism

    NASA Astrophysics Data System (ADS)

    Hu, X.; Zhu, X.; Li, D.

    2012-07-01

    TSR (Traffic sign recognition) is an important problem in ITS (intelligent traffic system), which is being paid more and more attention for realizing drivers assisting system and unmanned vehicle etc. TSR consists of two steps: detection and recognition, and this paper describe a new traffic sign detection method. The design principle of the traffic sign is comply with the visual attention mechanism of human, so we propose a method using visual attention mechanism to detect traffic sign ,which is reasonable. In our method, the whole scene will firstly be analyzed by visual attention model to acquire the area where traffic signs might be placed. And then, these candidate areas will be analyzed according to the shape characteristics of the traffic sign to detect traffic signs. In traffic sign detection experiments, the result shows the proposed method is effectively and robust than other existing saliency detection method.

  3. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    PubMed

    Kawai, Nobuyuki; He, Hongshen

    2016-01-01

    Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish) under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise). We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  4. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions

    PubMed Central

    He, Hongshen

    2016-01-01

    Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish) under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise). We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions. PMID:27783686

  5. Visual Salience in the Change Detection Paradigm: The Special Role of Object Onset

    ERIC Educational Resources Information Center

    Cole, Geoff G.; Kentridge, Robert W.; Heywood, Charles A.

    2004-01-01

    The relative efficacy with which appearance of a new object orients visual attention was investigated. At issue is whether the visual system treats onset as being of particular importance or only 1 of a number of stimulus events equally likely to summon attention. Using the 1-shot change detection paradigm, the authors compared detectability of…

  6. Conebeam CT of the head and neck, part 1: physical principles.

    PubMed

    Miracle, A C; Mukherji, S K

    2009-06-01

    Conebeam x-ray CT (CBCT) is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. This first installment in a 2-part review will address the physical principles underlying CBCT imaging as it is used in dedicated head and neck scanners. Concepts related to CBCT acquisition geometry, flat panel detection, and image quality will be explored in detail. Particular emphasis will be placed on technical limitations to low-contrast detectability and radiation dose. Proposed methods of x-ray scatter reduction will also be discussed.

  7. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    PubMed

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  8. Forensic applications of chemical imaging: latent fingerprint detection using visible absorption and luminescence.

    PubMed

    Exline, David L; Wallace, Christie; Roux, Claude; Lennard, Chris; Nelson, Matthew P; Treado, Patrick J

    2003-09-01

    Chemical imaging technology is a rapid examination technique that combines molecular spectroscopy and digital imaging, providing information on morphology, composition, structure, and concentration of a material. Among many other applications, chemical imaging offers an array of novel analytical testing methods, which limits sample preparation and provides high-quality imaging data essential in the detection of latent fingerprints. Luminescence chemical imaging and visible absorbance chemical imaging have been successfully applied to ninhydrin, DFO, cyanoacrylate, and luminescent dye-treated latent fingerprints, demonstrating the potential of this technology to aid forensic investigations. In addition, visible absorption chemical imaging has been applied successfully to visualize untreated latent fingerprints.

  9. Adaptive optics without altering visual perception

    PubMed Central

    DE, Koenig; NW, Hart; HJ, Hofer

    2014-01-01

    Adaptive optics combined with visual psychophysics creates the potential to study the relationship between visual function and the retina at the cellular scale. This potential is hampered, however, by visual interference from the wavefront-sensing beacon used during correction. For example, we have previously shown that even a dim, visible beacon can alter stimulus perception (Hofer, H. J., Blaschke, J., Patolia, J., & Koenig, D. E. (2012). Fixation light hue bias revisited: Implications for using adaptive optics to study color vision. Vision Research, 56, 49-56). Here we describe a simple strategy employing a longer wavelength (980nm) beacon that, in conjunction with appropriate restriction on timing and placement, allowed us to perform psychophysics when dark adapted without altering visual perception. The method was verified by comparing detection and color appearance of foveally presented small spot stimuli with and without the wavefront beacon present in 5 subjects. As an important caution, we found that significant perceptual interference can occur even with a subliminal beacon when additional measures are not taken to limit exposure. Consequently, the lack of perceptual interference should be verified for a given system, and not assumed based on invisibility of the beacon. PMID:24607992

  10. Evaluation of perception performance in neck dissection planning using eye tracking and attention landscapes

    NASA Astrophysics Data System (ADS)

    Burgert, Oliver; Örn, Veronika; Velichkovsky, Boris M.; Gessat, Michael; Joos, Markus; Strauß, Gero; Tietjen, Christian; Preim, Bernhard; Hertel, Ilka

    2007-03-01

    Neck dissection is a surgical intervention at which cervical lymph node metastases are removed. Accurate surgical planning is of high importance because wrong judgment of the situation causes severe harm for the patient. Diagnostic perception of radiological images by a surgeon is an acquired skill that can be enhanced by training and experience. To improve accuracy in detecting pathological lymph nodes by newcomers and less experienced professionals, it is essential to understand how surgical experts solve relevant visual and recognition tasks. By using eye tracking and especially the newly-developed attention landscapes visualizations, it could be determined whether visualization options, for example 3D models instead of CT data, help in increasing accuracy and speed of neck dissection planning. Thirteen ORL surgeons with different levels of expertise participated in this study. They inspected different visualizations of 3D models and original CT datasets of patients. Among others, we used scanpath analysis and attention landscapes to interpret the inspection strategies. It was possible to distinguish different patterns of visual exploratory activity. The experienced surgeons exhibited a higher concentration of attention on the limited number of areas of interest and demonstrated less saccadic eye movements indicating a better orientation.

  11. Dissociable Roles of Different Types of Working Memory Load in Visual Detection

    PubMed Central

    Konstantinou, Nikos; Lavie, Nilli

    2013-01-01

    We contrasted the effects of different types of working memory (WM) load on detection. Considering the sensory-recruitment hypothesis of visual short-term memory (VSTM) within load theory (e.g., Lavie, 2010) led us to predict that VSTM load would reduce visual-representation capacity, thus leading to reduced detection sensitivity during maintenance, whereas load on WM cognitive control processes would reduce priority-based control, thus leading to enhanced detection sensitivity for a low-priority stimulus. During the retention interval of a WM task, participants performed a visual-search task while also asked to detect a masked stimulus in the periphery. Loading WM cognitive control processes (with the demand to maintain a random digit order [vs. fixed in conditions of low load]) led to enhanced detection sensitivity. In contrast, loading VSTM (with the demand to maintain the color and positions of six squares [vs. one in conditions of low load]) reduced detection sensitivity, an effect comparable with that found for manipulating perceptual load in the search task. The results confirmed our predictions and established a new functional dissociation between the roles of different types of WM load in the fundamental visual perception process of detection. PMID:23713796

  12. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    PubMed

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  13. Replacement Condition Detection of Railway Point Machines Using an Electric Current Sensor.

    PubMed

    Sa, Jaewon; Choi, Younchang; Chung, Yongwha; Kim, Hee-Young; Park, Daihee; Yoon, Sukhan

    2017-01-29

    Detecting replacement conditions of railway point machines is important to simultaneously satisfy the budget-limit and train-safety requirements. In this study, we consider classification of the subtle differences in the aging effect-using electric current shape analysis-for the purpose of replacement condition detection of railway point machines. After analyzing the shapes of after-replacement data and then labeling the shapes of each before-replacement data, we can derive the criteria that can handle the subtle differences between "does-not-need-to-be-replaced" and "needs-to-be-replaced" shapes. On the basis of the experimental results with in-field replacement data, we confirmed that the proposed method could detect the replacement conditions with acceptable accuracy, as well as provide visual interpretability of the criteria used for the time-series classification.

  14. Replacement Condition Detection of Railway Point Machines Using an Electric Current Sensor

    PubMed Central

    Sa, Jaewon; Choi, Younchang; Chung, Yongwha; Kim, Hee-Young; Park, Daihee; Yoon, Sukhan

    2017-01-01

    Detecting replacement conditions of railway point machines is important to simultaneously satisfy the budget-limit and train-safety requirements. In this study, we consider classification of the subtle differences in the aging effect—using electric current shape analysis—for the purpose of replacement condition detection of railway point machines. After analyzing the shapes of after-replacement data and then labeling the shapes of each before-replacement data, we can derive the criteria that can handle the subtle differences between “does-not-need-to-be-replaced” and “needs-to-be-replaced” shapes. On the basis of the experimental results with in-field replacement data, we confirmed that the proposed method could detect the replacement conditions with acceptable accuracy, as well as provide visual interpretability of the criteria used for the time-series classification. PMID:28146057

  15. WiseView: Visualizing motion and variability of faint WISE sources

    NASA Astrophysics Data System (ADS)

    Caselden, Dan; Westin, Paul, III; Meisner, Aaron; Kuchner, Marc; Colin, Guillaume

    2018-06-01

    WiseView renders image blinks of Wide-field Infrared Survey Explorer (WISE) coadds spanning a multi-year time baseline in a browser. The software allows for easy visual identification of motion and variability for sources far beyond the single-frame detection limit, a key threshold not surmounted by many studies. WiseView transparently gathers small image cutouts drawn from many terabytes of unWISE coadds, facilitating access to this large and unique dataset. Users need only input the coordinates of interest and can interactively tune parameters including the image stretch, colormap and blink rate. WiseView was developed in the context of the Backyard Worlds: Planet 9 citizen science project, and has enabled hundreds of brown dwarf candidate discoveries by citizen scientists and professional astronomers.

  16. Competitive immunochromatographic assay for the detection of thiodiglycol sulfoxide, a degradation product of sulfur mustard.

    PubMed

    Sathe, Manisha; Srivastava, Shruti; Merwyn, S; Agarwal, G S; Kaushik, M P

    2014-10-21

    An immunochromatographic assay (ICA) based on the competitive antigen-coated format using colloidal gold as the label was developed for the detection of thiodiglycol sulfoxide (TDGO), an important metabolite and degradation compound of sulphur mustard (SM). The ICA test strip consisted of a membrane with a detection zone, a sample pad and an absorbent pad. The membrane was separately coated with hapten-OVA conjugate (test line) and anti-rabbit mouse IgG (control line). The visual detection limit for TDGO by ICA detection was found to be 10 μg mL(-1). For validation, the ICA results obtained for spiked water samples were in good agreement with those obtained by indirect competitive inhibition enzyme-linked immunosorbent assay (ELISA) for TDGO. The assay time for detection was less than 10 min. The developed ICA has the potential to be a useful on-site screening tool for the retrospective detection of SM in environmental samples.

  17. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    PubMed Central

    Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai

    2013-01-01

    In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water. PMID:23539028

  18. Paper-based Platform for Urinary Creatinine Detection.

    PubMed

    Sittiwong, Jarinya; Unob, Fuangfa

    2016-01-01

    A new paper platform was developed for the colorimetric detection of creatinine. The filter paper was coated with 3-propylsulfonic acid trimethoxysilane and used as the platform. Creatinine in a cationic form was extracted onto the paper via an ion-exchange mechanism and detected through the Jaffé reaction, resulting in a yellow-orange color complex. The color change on the paper could be observed visually, and the quantitative detection of creatinine was achieved through monitoring the color intensity change. The color intensity of creatinine complexes on the paper platform as a function of the creatinine concentration provided a linear range for creatinine detection in the range of 10 - 60 mg L(-1) and a detection limit of 4.2 mg L(-1). The accuracy of the proposed paper-based method was comparable to the conventional standard Jaffé method. This paper platform could be applied for simple and rapid detection of creatinine in human urine samples with a low consumption of reagent.

  19. Traffic light detection and intersection crossing using mobile computer vision

    NASA Astrophysics Data System (ADS)

    Grewei, Lynne; Lagali, Christopher

    2017-05-01

    The solution for Intersection Detection and Crossing to support the development of blindBike an assisted biking system for the visually impaired is discussed. Traffic light detection and intersection crossing are key needs in the task of biking. These problems are tackled through the use of mobile computer vision, in the form of a mobile application on an Android phone. This research builds on previous Traffic Light detection algorithms with a focus on efficiency and compatibility on a resource-limited platform. Light detection is achieved through blob detection algorithms utilizing training data to detect patterns of Red, Green and Yellow in complex real world scenarios where multiple lights may be present. Also, issues of obscurity and scale are addressed. Safe Intersection crossing in blindBike is also discussed. This module takes a conservative "assistive" technology approach. To achieve this blindBike use's not only the Android device but, an external bike cadence Bluetooth/Ant enabled sensor. Real world testing results are given and future work is discussed.

  20. A results-based process for evaluation of diverse visual analytics tools

    NASA Astrophysics Data System (ADS)

    Rubin, Gary; Berger, David H.

    2013-05-01

    With the pervasiveness of still and full-motion imagery in commercial and military applications, the need to ingest and analyze these media has grown rapidly in recent years. Additionally, video hosting and live camera websites provide a near real-time view of our changing world with unprecedented spatial coverage. To take advantage of these controlled and crowd-sourced opportunities, sophisticated visual analytics (VA) tools are required to accurately and efficiently convert raw imagery into usable information. Whether investing in VA products or evaluating algorithms for potential development, it is important for stakeholders to understand the capabilities and limitations of visual analytics tools. Visual analytics algorithms are being applied to problems related to Intelligence, Surveillance, and Reconnaissance (ISR), facility security, and public safety monitoring, to name a few. The diversity of requirements means that a onesize- fits-all approach to performance assessment will not work. We present a process for evaluating the efficacy of algorithms in real-world conditions, thereby allowing users and developers of video analytics software to understand software capabilities and identify potential shortcomings. The results-based approach described in this paper uses an analysis of end-user requirements and Concept of Operations (CONOPS) to define Measures of Effectiveness (MOEs), test data requirements, and evaluation strategies. We define metrics that individually do not fully characterize a system, but when used together, are a powerful way to reveal both strengths and weaknesses. We provide examples of data products, such as heatmaps, performance maps, detection timelines, and rank-based probability-of-detection curves.

  1. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    PubMed

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Neural Anatomy of Primary Visual Cortex Limits Visual Working Memory.

    PubMed

    Bergmann, Johanna; Genç, Erhan; Kohler, Axel; Singer, Wolf; Pearson, Joel

    2016-01-01

    Despite the immense processing power of the human brain, working memory storage is severely limited, and the neuroanatomical basis of these limitations has remained elusive. Here, we show that the stable storage limits of visual working memory for over 9 s are bound by the precise gray matter volume of primary visual cortex (V1), defined by fMRI retinotopic mapping. Individuals with a bigger V1 tended to have greater visual working memory storage. This relationship was present independently for both surface size and thickness of V1 but absent in V2, V3 and for non-visual working memory measures. Additional whole-brain analyses confirmed the specificity of the relationship to V1. Our findings indicate that the size of primary visual cortex plays a critical role in limiting what we can hold in mind, acting like a gatekeeper in constraining the richness of working mental function. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. Slow changing postural cues cancel visual field dependence on self-tilt detection.

    PubMed

    Scotto Di Cesare, C; Macaluso, T; Mestre, D R; Bringoux, L

    2015-01-01

    Interindividual differences influence the multisensory integration process involved in spatial perception. Here, we assessed the effect of visual field dependence on self-tilt detection relative to upright, as a function of static vs. slow changing visual or postural cues. To that aim, we manipulated slow rotations (i.e., 0.05° s(-1)) of the body and/or the visual scene in pitch. Participants had to indicate whether they felt being tilted forward at successive angles. Results show that thresholds for self-tilt detection substantially differed between visual field dependent/independent subjects, when only the visual scene was rotated. This difference was no longer present when the body was actually rotated, whatever the visual scene condition (i.e., absent, static or rotated relative to the observer). These results suggest that the cancellation of visual field dependence by dynamic postural cues may rely on a multisensory reweighting process, where slow changing vestibular/somatosensory inputs may prevail over visual inputs. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Dual-labeling with 5-aminolevulinic acid and fluorescein for fluorescence-guided resection of high-grade gliomas: technical note.

    PubMed

    Suero Molina, Eric; Wölfer, Johannes; Ewelt, Christian; Ehrhardt, André; Brokinkel, Benjamin; Stummer, Walter

    2018-02-01

    OBJECTIVE Fluorescence guidance with 5-aminolevulinic acid (5-ALA) helps improve resections of malignant gliomas. However, one limitation is the low intensity of blue light for background illumination. Fluorescein has recently been reintroduced into neurosurgery, and novel microscope systems are available for visualizing this fluorochrome, which highlights all perfused tissues but has limited selectivity for tumor detection. Here, the authors investigate a combination of both fluorochromes: 5-ALA for distinguishing tumor and fluorescein for providing tissue fluorescence of adjacent brain tissue. METHODS The authors evaluated 6 patients who harbored cerebral lesions suggestive of high-grade glioma. Patients received 5-ALA (20 mg/kg) orally 4 hours before induction of anesthesia. Low-dose fluorescein (3 mg/kg intravenous) was injected immediately after anesthesia induction. Pentero microscopes (equipped either with Yellow 560 or Blue 400 filters) were used to visualize fluorescence. To simultaneously visualize both fluorochromes, the Yellow 560 module was combined with external blue light illumination (D-light C System). RESULTS Fluorescein-induced fluorescence created a useful background for protoporphyrin IX (PPIX) fluorescence, which appeared orange to red, surrounded by greenly fluorescent normal brain and edematous tissue. Green brain-tissue fluorescence was helpful in augmenting background. Levels of blue illumination that were too strong obscured PPIX fluorescence. Unspecific extravasation of fluorescein was noted at resection margins, which did not interfere with PPIX fluorescence detection. CONCLUSIONS Dual labeling with both PPIX and fluorescein fluorescence is feasible and gives superior background information during fluorescence-guided resections. The authors believe that this technique carries potential as a next step in fluorescence-guided resections if it is completely integrated into the surgical microscope.

  5. Are multiple visual short-term memory storages necessary to explain the retro-cue effect?

    PubMed

    Makovski, Tal

    2012-06-01

    Recent research has shown that change detection performance is enhanced when, during the retention interval, attention is cued to the location of the upcoming test item. This retro-cue advantage has led some researchers to suggest that visual short-term memory (VSTM) is divided into a durable, limited-capacity storage and a more fragile, high-capacity storage. Consequently, performance is poor on the no-cue trials because fragile VSTM is overwritten by the test display and only durable VSTM is accessible under these conditions. In contrast, performance is improved in the retro-cue condition because attention keeps fragile VSTM accessible. The aim of the present study was to test the assumptions underlying this two-storage account. Participants were asked to encode an array of colors for a change detection task involving no-cue and retro-cue trials. A retro-cue advantage was found even when the cue was presented after a visual (Experiment 1) or a central (Experiment 2) interference. Furthermore, the magnitude of the interference was comparable between the no-cue and retro-cue trials. These data undermine the main empirical support for the two-storage account and suggest that the presence of a retro-cue benefit cannot be used to differentiate between different VSTM storages.

  6. A rapid Salmonella detection method involving thermophilic helicase-dependent amplification and a lateral flow assay.

    PubMed

    Du, Xin-Jun; Zhou, Tian-Jiao; Li, Ping; Wang, Shuo

    2017-08-01

    Salmonella is a major foodborne pathogen that is widespread in the environment and can cause serious human and animal disease. Since conventional culture methods to detect Salmonella are time-consuming and laborious, rapid and accurate techniques to detect this pathogen are critically important for food safety and diagnosing foodborne illness. In this study, we developed a rapid, simple and portable Salmonella detection strategy that combines thermophilic helicase-dependent amplification (tHDA) with a lateral flow assay to provide a detection result based on visual signals within 90 min. Performance analyses indicated that the method had detection limits for DNA and pure cultured bacteria of 73.4-80.7 fg and 35-40 CFU, respectively. Specificity analyses showed no cross reactions with Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Enterobacter aerogenes, Shigella and Campylobacter jejuni. The results for detection in real food samples showed that 1.3-1.9 CFU/g or 1.3-1.9 CFU/mL of Salmonella in contaminated chicken products and infant nutritional cereal could be detected after 2 h of enrichment. The same amount of Salmonella in contaminated milk could be detected after 4 h of enrichment. This tHDA-strip can be used for the rapid detection of Salmonella in food samples and is particularly suitable for use in areas with limited equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Initial evaluation of the geologic applications of ERTS-1 imagery for New Mexico

    NASA Technical Reports Server (NTRS)

    Vonderlinden, K.; Kottlowski, F. E.

    1973-01-01

    Coverage of approximately one-third of the test site, the state of New Mexico, had been received by January 31, 1973 and all of the images received were MSS products. Features noted during visual inspection of 91/2 x 91/2 prints include major structural forms, vegetation patterns, drainage patterns and outcrops of geologic formations having marked color contrasts. The Border Hills Structural Zone and the Y-O Structural Zone are prominently reflected in coverage of the Pecos Valley. A study of available maps and remote sensing material covering the Deming-Columbus area indicated that the limit of detection and the resolution of MSS products are not as good as those of aerial photographs, geologic maps, and manned-satellite photographs. The limit of detection of high contrast features on MSS prints in approximately 1000 feet or 300 meters for linear features and about 18 acres for roughly circular areas.

  8. Deep convolutional neural network for the automated detection and diagnosis of seizure using EEG signals.

    PubMed

    Acharya, U Rajendra; Oh, Shu Lih; Hagiwara, Yuki; Tan, Jen Hong; Adeli, Hojjat

    2017-09-27

    An encephalogram (EEG) is a commonly used ancillary test to aide in the diagnosis of epilepsy. The EEG signal contains information about the electrical activity of the brain. Traditionally, neurologists employ direct visual inspection to identify epileptiform abnormalities. This technique can be time-consuming, limited by technical artifact, provides variable results secondary to reader expertise level, and is limited in identifying abnormalities. Therefore, it is essential to develop a computer-aided diagnosis (CAD) system to automatically distinguish the class of these EEG signals using machine learning techniques. This is the first study to employ the convolutional neural network (CNN) for analysis of EEG signals. In this work, a 13-layer deep convolutional neural network (CNN) algorithm is implemented to detect normal, preictal, and seizure classes. The proposed technique achieved an accuracy, specificity, and sensitivity of 88.67%, 90.00% and 95.00%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Development and Application of Loop-Mediated Isothermal Amplification Assays for Rapid Visual Detection of cry2Ab and cry3A Genes in Genetically-Modified Crops

    PubMed Central

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-01-01

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field. PMID:25167136

  10. Development and application of loop-mediated isothermal amplification assays for rapid visual detection of cry2Ab and cry3A genes in genetically-modified crops.

    PubMed

    Li, Feiwu; Yan, Wei; Long, Likun; Qi, Xing; Li, Congcong; Zhang, Shihong

    2014-08-27

    The cry2Ab and cry3A genes are two of the most important insect-resistant exogenous genes and had been widely used in genetically-modified crops. To develop more effective alternatives for the quick identification of genetically-modified organisms (GMOs) containing these genes, a rapid and visual loop-mediated isothermal amplification (LAMP) method to detect the cry2Ab and cry3A genes is described in this study. The LAMP assay can be finished within 60 min at an isothermal condition of 63 °C. The derived LAMP products can be obtained by a real-time turbidimeter via monitoring the white turbidity or directly observed by the naked eye through adding SYBR Green I dye. The specificity of the LAMP assay was determined by analyzing thirteen insect-resistant genetically-modified (GM) crop events with different Bt genes. Furthermore, the sensitivity of the LAMP assay was evaluated by diluting the template genomic DNA. Results showed that the limit of detection of the established LAMP assays was approximately five copies of haploid genomic DNA, about five-fold greater than that of conventional PCR assays. All of the results indicated that this established rapid and visual LAMP assay was quick, accurate and cost effective, with high specificity and sensitivity. In addition, this method does not need specific expensive instruments or facilities, which can provide a simpler and quicker approach to detecting the cry2Ab and cry3A genes in GM crops, especially for on-site, large-scale test purposes in the field.

  11. Assessing the accuracy and feasibility of a refractive error screening program conducted by school teachers in pre-primary and primary schools in Thailand.

    PubMed

    Teerawattananon, Kanlaya; Myint, Chaw-Yin; Wongkittirux, Kwanjai; Teerawattananon, Yot; Chinkulkitnivat, Bunyong; Orprayoon, Surapong; Kusakul, Suwat; Tengtrisorn, Supaporn; Jenchitr, Watanee

    2014-01-01

    As part of the development of a system for the screening of refractive error in Thai children, this study describes the accuracy and feasibility of establishing a program conducted by teachers. To assess the accuracy and feasibility of screening by teachers. A cross-sectional descriptive and analytical study was conducted in 17 schools in four provinces representing four geographic regions in Thailand. A two-staged cluster sampling was employed to compare the detection rate of refractive error among eligible students between trained teachers and health professionals. Serial focus group discussions were held for teachers and parents in order to understand their attitude towards refractive error screening at schools and the potential success factors and barriers. The detection rate of refractive error screening by teachers among pre-primary school children is relatively low (21%) for mild visual impairment but higher for moderate visual impairment (44%). The detection rate for primary school children is high for both levels of visual impairment (52% for mild and 74% for moderate). The focus group discussions reveal that both teachers and parents would benefit from further education regarding refractive errors and that the vast majority of teachers are willing to conduct a school-based screening program. Refractive error screening by health professionals in pre-primary and primary school children is not currently implemented in Thailand due to resource limitations. However, evidence suggests that a refractive error screening program conducted in schools by teachers in the country is reasonable and feasible because the detection and treatment of refractive error in very young generations is important and the screening program can be implemented and conducted with relatively low costs.

  12. A new kind of highly sensitive competitive lateral flow immunoassay displaying direct analyte-signal dependence. Application to the determination of the mycotoxin deoxynivalenol.

    PubMed

    Urusov, Alexandr E; Gubaidullina, Miliausha K; Petrakova, Alina V; Zherdev, Anatoly V; Dzantiev, Boris B

    2017-12-06

    A new kind of competitive immunochromatographic assay is presented. It is based on the use of a test strip loaded with (a) labeled specific antibodies, (b) a hapten-protein conjugate at the control zone, and (c) antibodies interacting with the specific antibodies in the analytical zone. In the case where a sample does not contain the target antigen (hapten), all labeled antibodies remain in the control zone because of the selected ratio of reactants. The analytical zone remains colorless because the labeled antibodies do not reach it. If an antigen is present in the sample, it interferes with the binding of the specific antibodies in the control zone and knocks them out. Some of these antibodies pass the control zone to form a colored line in the analytical zone. The intensity of the color is directly proportional to the amount of the target antigen in the sample. The assay has an attractive feature in that an appearance in coloration is more easily detected visually than a decoloration. Moreover, the onset of coloration is detectable at a lower concentration than a decoloration. The new detection scheme was applied to the determination of the mycotoxin deoxynivalenol. The visual limit of detection is 2 ng·mL -1 in corn extracts (35 ng per gram of sample). With the same reagents, this is lower by a factor of 60 than the established test strip. The assay takes only 15 min. This new kind of assay has wide potential applications for numerous low molecular weight analytes. Graphical abstract Competitive immunochromatography with direct analyte-signal dependence is proposed. It provides a 60-fold decrease of the detection limit for mycotoxin deoxynivalenol. The analyte-antibody-label complexes move along the immobilized antigen (control zone) and bind with anti-species antibodies (test zone).

  13. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    PubMed

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  14. Cognitive Control Network Contributions to Memory-Guided Visual Attention.

    PubMed

    Rosen, Maya L; Stern, Chantal E; Michalka, Samantha W; Devaney, Kathryn J; Somers, David C

    2016-05-01

    Visual attentional capacity is severely limited, but humans excel in familiar visual contexts, in part because long-term memories guide efficient deployment of attention. To investigate the neural substrates that support memory-guided visual attention, we performed a set of functional MRI experiments that contrast long-term, memory-guided visuospatial attention with stimulus-guided visuospatial attention in a change detection task. Whereas the dorsal attention network was activated for both forms of attention, the cognitive control network(CCN) was preferentially activated during memory-guided attention. Three posterior nodes in the CCN, posterior precuneus, posterior callosal sulcus/mid-cingulate, and lateral intraparietal sulcus exhibited the greatest specificity for memory-guided attention. These 3 regions exhibit functional connectivity at rest, and we propose that they form a subnetwork within the broader CCN. Based on the task activation patterns, we conclude that the nodes of this subnetwork are preferentially recruited for long-term memory guidance of visuospatial attention. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  15. Force sensor attachable to thin fiberscopes/endoscopes utilizing high elasticity fabric.

    PubMed

    Watanabe, Tetsuyou; Iwai, Takanobu; Fujihira, Yoshinori; Wakako, Lina; Kagawa, Hiroyuki; Yoneyama, Takeshi

    2014-03-12

    An endoscope/fiberscope is a minimally invasive tool used for directly observing tissues in areas deep inside the human body where access is limited. However, this tool only yields visual information. If force feedback information were also available, endoscope/fiberscope operators would be able to detect indurated areas that are visually hard to recognize. Furthermore, obtaining such feedback information from tissues in areas where collecting visual information is a challenge would be highly useful. The major obstacle is that such force information is difficult to acquire. This paper presents a novel force sensing system that can be attached to a very thin fiberscope/endoscope. To ensure a small size, high resolution, easy sterilization, and low cost, the proposed force visualization-based system uses a highly elastic material-panty stocking fabric. The paper also presents the methodology for deriving the force value from the captured image. The system has a resolution of less than 0.01 N and sensitivity of greater than 600 pixels/N within the force range of 0-0.2 N.

  16. Development of colloidal gold-based immunochromatographic assay for rapid detection of Mycoplasma suis in porcine plasma.

    PubMed

    Meng, Kai; Sun, Wenjing; Zhao, Peng; Zhang, Limei; Cai, Dongjie; Cheng, Ziqiang; Guo, Huijun; Liu, Jianzhu; Yang, Dubao; Wang, Shujing; Chai, Tongjie

    2014-05-15

    A one-step immunochromatographic assay using gold nanoparticles coated with polyclonal antibody (pAb) against Mycoplasma suis (M. suis) was developed in this study for the detection of M. suis in porcine plasma. The colloidal gold was prepared by the reduction of gold salt with sodium citrate coupled with pAb against M. suis. The pAb was produced by immunizing the BALB/c mice with recombinant MSG1 (rMSG1) protein from M. suis expressed in Escherichia coli. The optimal concentrations of the capture antibody and the coating antibody were 12 μg/ml and 1.5 mg/ml, respectively, and that of the blocking buffer was 1% bovine serum albumin. The lower detection limit of the immunochromatographic assay test was 100 ng/ml with visual detection under optimal conditions of analysis. Classical swine fever virus, porcine reproductive and respiratory syndrome virus, swine pneumonia mycoplasma, swine toxoplasma, and porcine parvovirus were used to evaluate the specificity of the immunochromatographic strips. No cross-reaction of the antibodies with other related swine pathogens was observed. This qualitative test based on the visual evaluation of the results did not require any equipment. The assay time for M. suis detection was less than 10 min, suitable for rapid detection at the grassroots level. The one-step colloidal gold immunochromatographic strips that we developed had high specificity and sensitivity. Therefore, this method would be feasible, convenient, rapid, and effective for detecting M. suis in porcine plasma. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Eye movements and attention: The role of pre-saccadic shifts of attention in perception, memory and the control of saccades

    PubMed Central

    Gersch, Timothy M.; Schnitzer, Brian S.; Dosher, Barbara A.; Kowler, Eileen

    2012-01-01

    Saccadic eye movements and perceptual attention work in a coordinated fashion to allow selection of the objects, features or regions with the greatest momentary need for limited visual processing resources. This study investigates perceptual characteristics of pre-saccadic shifts of attention during a sequence of saccades using the visual manipulations employed to study mechanisms of attention during maintained fixation. The first part of this paper reviews studies of the connections between saccades and attention, and their significance for both saccadic control and perception. The second part presents three experiments that examine the effects of pre-saccadic shifts of attention on vision during sequences of saccades. Perceptual enhancements at the saccadic goal location relative to non-goal locations were found across a range of stimulus contrasts, with either perceptual discrimination or detection tasks, with either single or multiple perceptual targets, and regardless of the presence of external noise. The results show that the preparation of saccades can evoke a variety of attentional effects, including attentionally-mediated changes in the strength of perceptual representations, selection of targets for encoding in visual memory, exclusion of external noise, or changes in the levels of internal visual noise. The visual changes evoked by saccadic planning make it possible for the visual system to effectively use saccadic eye movements to explore the visual environment. PMID:22809798

  18. Needle tip visualization by bevel-point ultrasound generator and prototype photoacoustic imaging system

    NASA Astrophysics Data System (ADS)

    Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro

    2017-03-01

    Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.

  19. Using a visual discrimination model for the detection of compression artifacts in virtual pathology images.

    PubMed

    Johnson, Jeffrey P; Krupinski, Elizabeth A; Yan, Michelle; Roehrig, Hans; Graham, Anna R; Weinstein, Ronald S

    2011-02-01

    A major issue in telepathology is the extremely large and growing size of digitized "virtual" slides, which can require several gigabytes of storage and cause significant delays in data transmission for remote image interpretation and interactive visualization by pathologists. Compression can reduce this massive amount of virtual slide data, but reversible (lossless) methods limit data reduction to less than 50%, while lossy compression can degrade image quality and diagnostic accuracy. "Visually lossless" compression offers the potential for using higher compression levels without noticeable artifacts, but requires a rate-control strategy that adapts to image content and loss visibility. We investigated the utility of a visual discrimination model (VDM) and other distortion metrics for predicting JPEG 2000 bit rates corresponding to visually lossless compression of virtual slides for breast biopsy specimens. Threshold bit rates were determined experimentally with human observers for a variety of tissue regions cropped from virtual slides. For test images compressed to their visually lossless thresholds, just-noticeable difference (JND) metrics computed by the VDM were nearly constant at the 95th percentile level or higher, and were significantly less variable than peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics. Our results suggest that VDM metrics could be used to guide the compression of virtual slides to achieve visually lossless compression while providing 5-12 times the data reduction of reversible methods.

  20. Using component technologies for web based wavelet enhanced mammographic image visualization.

    PubMed

    Sakellaropoulos, P; Costaridou, L; Panayiotakis, G

    2000-01-01

    The poor contrast detectability of mammography can be dealt with by domain specific software visualization tools. Remote desktop client access and time performance limitations of a previously reported visualization tool are addressed, aiming at more efficient visualization of mammographic image resources existing in web or PACS image servers. This effort is also motivated by the fact that at present, web browsers do not support domain-specific medical image visualization. To deal with desktop client access the tool was redesigned by exploring component technologies, enabling the integration of stand alone domain specific mammographic image functionality in a web browsing environment (web adaptation). The integration method is based on ActiveX Document Server technology. ActiveX Document is a part of Object Linking and Embedding (OLE) extensible systems object technology, offering new services in existing applications. The standard DICOM 3.0 part 10 compatible image-format specification Papyrus 3.0 is supported, in addition to standard digitization formats such as TIFF. The visualization functionality of the tool has been enhanced by including a fast wavelet transform implementation, which allows for real time wavelet based contrast enhancement and denoising operations. Initial use of the tool with mammograms of various breast structures demonstrated its potential in improving visualization of diagnostic mammographic features. Web adaptation and real time wavelet processing enhance the potential of the previously reported tool in remote diagnosis and education in mammography.

  1. Bioelectronic nose and its application to smell visualization.

    PubMed

    Ko, Hwi Jin; Park, Tai Hyun

    2016-01-01

    There have been many trials to visualize smell using various techniques in order to objectively express the smell because information obtained from the sense of smell in human is very subjective. So far, well-trained experts such as a perfumer, complex and large-scale equipment such as GC-MS, and an electronic nose have played major roles in objectively detecting and recognizing odors. Recently, an optoelectronic nose was developed to achieve this purpose, but some limitations regarding the sensitivity and the number of smells that can be visualized still persist. Since the elucidation of the olfactory mechanism, numerous researches have been accomplished for the development of a sensing device by mimicking human olfactory system. Engineered olfactory cells were constructed to mimic the human olfactory system, and the use of engineered olfactory cells for smell visualization has been attempted with the use of various methods such as calcium imaging, CRE reporter assay, BRET, and membrane potential assay; however, it is not easy to consistently control the condition of cells and it is impossible to detect low odorant concentration. Recently, the bioelectronic nose was developed, and much improved along with the improvement of nano-biotechnology. The bioelectronic nose consists of the following two parts: primary transducer and secondary transducer. Biological materials as a primary transducer improved the selectivity of the sensor, and nanomaterials as a secondary transducer increased the sensitivity. Especially, the bioelectronic noses using various nanomaterials combined with human olfactory receptors or nanovesicles derived from engineered olfactory cells have a potential which can detect almost all of the smells recognized by human because an engineered olfactory cell might be able to express any human olfactory receptor as well as can mimic human olfactory system. Therefore, bioelectronic nose will be a potent tool for smell visualization, but only if two technologies are completed. First, a multi-channel array-sensing system has to be applied for the integration of all of the olfactory receptors into a single chip for mimicking the performance of human nose. Second, the processing technique of the multi-channel system signals should be simultaneously established with the conversion of the signals to visual images. With the use of this latest sensing technology, the realization of a proper smell-visualization technology is expected in the near future.

  2. Determining the Requisite Components of Visual Threat Detection to Improve Operational Performance

    DTIC Science & Technology

    2014-04-01

    cognitive processes, and may be enhanced by focusing training development on the principle components such as causal reasoning. The second report will...discuss the development and evaluation of a research-based training exemplar. Visual threat detection pervades many military contexts, but is also... developing computer-controlled exercises to study the primary components of visual threat detection. Similarly, civilian law enforcement officers were

  3. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance-ultrasound fusion biopsy may optimize the detection of prostate cancer. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. A matter of time: improvement of visual temporal processing during training-induced restoration of light detection performance

    PubMed Central

    Poggel, Dorothe A.; Treutwein, Bernhard; Sabel, Bernhard A.; Strasburger, Hans

    2015-01-01

    The issue of how basic sensory and temporal processing are related is still unresolved. We studied temporal processing, as assessed by simple visual reaction times (RT) and double-pulse resolution (DPR), in patients with partial vision loss after visual pathway lesions and investigated whether vision restoration training (VRT), a training program designed to improve light detection performance, would also affect temporal processing. Perimetric and campimetric visual field tests as well as maps of DPR thresholds and RT were acquired before and after a 3 months training period with VRT. Patient performance was compared to that of age-matched healthy subjects. Intact visual field size increased during training. Averaged across the entire visual field, DPR remained constant while RT improved slightly. However, in transition zones between the blind and intact areas (areas of residual vision) where patients had shown between 20 and 80% of stimulus detection probability in pre-training visual field tests, both DPR and RT improved markedly. The magnitude of improvement depended on the defect depth (or degree of intactness) of the respective region at baseline. Inter-individual training outcome variability was very high, with some patients showing little change and others showing performance approaching that of healthy controls. Training-induced improvement of light detection in patients with visual field loss thus generalized to dynamic visual functions. The findings suggest that similar neural mechanisms may underlie the impairment and subsequent training-induced functional recovery of both light detection and temporal processing. PMID:25717307

  5. Size as a determinant of reading speed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, I.; Clear, R.; Berman, S.

    1992-03-01

    The speed of reading unrelated words as a function of luminance, size, and contrast, was measured with an eye movement monitor for fifteen young adults. Subjects read up to 5,000 words in a test session, with the exact number depending upon their acuity. The size of the smallest legible print at a given luminance and contrast for these subjects was found to fit well to the Blackwell-Taylor detection threshold data above about 1 minute of arc. At lower sizes inclusion of a resolution size term provided an excellent fit. Reading speed was fit to a number of visual performance models.more » It was found that for most subjects that a ratio of the print size to an estimate of the threshold print size (a VL{sub size}) gave the best fits to the data. The threshold size was computed with a fit to the Blackwell-Taylor detection threshold data, modified to include a resolution size term as above. For the sole remaining subject a slightly better fit was obtained with a VL{sub contrast} model, where again the thresholds were modified by a limiting size term. The implication of these results for visual performance modeling is discussed. The reading speed for all subjects varied rapidly with size near the acuity limit, but became almost independent of visibility parameters as long as size is two times the acuity limit. These results show that size is a powerful determinant of reading speed, and suggest that minification of about 1/2 power could be used as a field test for adequate visibility.« less

  6. Size as a determinant of reading speed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, I.; Clear, R.; Berman, S.

    1992-03-01

    The speed of reading unrelated words as a function of luminance, size, and contrast, was measured with an eye movement monitor for fifteen young adults. Subjects read up to 5,000 words in a test session, with the exact number depending upon their acuity. The size of the smallest legible print at a given luminance and contrast for these subjects was found to fit well to the Blackwell-Taylor detection threshold data above about 1 minute of arc. At lower sizes inclusion of a resolution size term provided an excellent fit. Reading speed was fit to a number of visual performance models.more » It was found that for most subjects that a ratio of the print size to an estimate of the threshold print size (a VL[sub size]) gave the best fits to the data. The threshold size was computed with a fit to the Blackwell-Taylor detection threshold data, modified to include a resolution size term as above. For the sole remaining subject a slightly better fit was obtained with a VL[sub contrast] model, where again the thresholds were modified by a limiting size term. The implication of these results for visual performance modeling is discussed. The reading speed for all subjects varied rapidly with size near the acuity limit, but became almost independent of visibility parameters as long as size is two times the acuity limit. These results show that size is a powerful determinant of reading speed, and suggest that minification of about 1/2 power could be used as a field test for adequate visibility.« less

  7. Capacity and precision in an animal model of visual short-term memory.

    PubMed

    Lara, Antonio H; Wallis, Jonathan D

    2012-03-14

    Temporary storage of information in visual short-term memory (VSTM) is a key component of many complex cognitive abilities. However, it is highly limited in capacity. Understanding the neurophysiological nature of this capacity limit will require a valid animal model of VSTM. We used a multiple-item color change detection task to measure macaque monkeys' VSTM capacity. Subjects' performance deteriorated and reaction times increased as a function of the number of items in memory. Additionally, we measured the precision of the memory representations by varying the distance between sample and test colors. In trials with similar sample and test colors, subjects made more errors compared to trials with highly discriminable colors. We modeled the error distribution as a Gaussian function and used this to estimate the precision of VSTM representations. We found that as the number of items in memory increases the precision of the representations decreases dramatically. Additionally, we found that focusing attention on one of the objects increases the precision with which that object is stored and degrades the precision of the remaining. These results are in line with recent findings in human psychophysics and provide a solid foundation for understanding the neurophysiological nature of the capacity limit of VSTM.

  8. The visual analysis of emotional actions.

    PubMed

    Chouchourelou, Arieta; Matsuka, Toshihiko; Harber, Kent; Shiffrar, Maggie

    2006-01-01

    Is the visual analysis of human actions modulated by the emotional content of those actions? This question is motivated by a consideration of the neuroanatomical connections between visual and emotional areas. Specifically, the superior temporal sulcus (STS), known to play a critical role in the visual detection of action, is extensively interconnected with the amygdala, a center for emotion processing. To the extent that amygdala activity influences STS activity, one would expect to find systematic differences in the visual detection of emotional actions. A series of psychophysical studies tested this prediction. Experiment 1 identified point-light walker movies that convincingly depicted five different emotional states: happiness, sadness, neutral, anger, and fear. In Experiment 2, participants performed a walker detection task with these movies. Detection performance was systematically modulated by the emotional content of the gaits. Participants demonstrated the greatest visual sensitivity to angry walkers. The results of Experiment 3 suggest that local velocity cues to anger may account for high false alarm rates to the presence of angry gaits. These results support the hypothesis that the visual analysis of human action depends upon emotion processes.

  9. Mouse V1 population correlates of visual detection rely on heterogeneity within neuronal response patterns

    PubMed Central

    Montijn, Jorrit S; Goltstein, Pieter M; Pennartz, Cyriel MA

    2015-01-01

    Previous studies have demonstrated the importance of the primary sensory cortex for the detection, discrimination, and awareness of visual stimuli, but it is unknown how neuronal populations in this area process detected and undetected stimuli differently. Critical differences may reside in the mean strength of responses to visual stimuli, as reflected in bulk signals detectable in functional magnetic resonance imaging, electro-encephalogram, or magnetoencephalography studies, or may be more subtly composed of differentiated activity of individual sensory neurons. Quantifying single-cell Ca2+ responses to visual stimuli recorded with in vivo two-photon imaging, we found that visual detection correlates more strongly with population response heterogeneity rather than overall response strength. Moreover, neuronal populations showed consistencies in activation patterns across temporally spaced trials in association with hit responses, but not during nondetections. Contrary to models relying on temporally stable networks or bulk signaling, these results suggest that detection depends on transient differentiation in neuronal activity within cortical populations. DOI: http://dx.doi.org/10.7554/eLife.10163.001 PMID:26646184

  10. Effects of action video game training on visual working memory.

    PubMed

    Blacker, Kara J; Curby, Kim M; Klobusicky, Elizabeth; Chein, Jason M

    2014-10-01

    The ability to hold visual information in mind over a brief delay is critical for acquiring information and navigating a complex visual world. Despite the ubiquitous nature of visual working memory (VWM) in our everyday lives, this system is fundamentally limited in capacity. Therefore, the potential to improve VWM through training is a growing area of research. An emerging body of literature suggests that extensive experience playing action video games yields a myriad of perceptual and attentional benefits. Several lines of converging work suggest that action video game play may influence VWM as well. The current study utilized a training paradigm to examine whether action video games cause improvements to the quantity and/or the quality of information stored in VWM. The results suggest that VWM capacity, as measured by a change detection task, is increased after action video game training, as compared with training on a control game, and that some improvement to VWM precision occurs with action game training as well. However, these findings do not appear to extend to a complex span measure of VWM, which is often thought to tap into higher-order executive skills. The VWM improvements seen in individuals trained on an action video game cannot be accounted for by differences in motivation or engagement, differential expectations, or baseline differences in demographics as compared with the control group used. In sum, action video game training represents a potentially unique and engaging platform by which this severely capacity-limited VWM system might be enhanced.

  11. A lightweight, inexpensive robotic system for insect vision.

    PubMed

    Sabo, Chelsea; Chisholm, Robert; Petterson, Adam; Cope, Alex

    2017-09-01

    Designing hardware for miniaturized robotics which mimics the capabilities of flying insects is of interest, because they share similar constraints (i.e. small size, low weight, and low energy consumption). Research in this area aims to enable robots with similarly efficient flight and cognitive abilities. Visual processing is important to flying insects' impressive flight capabilities, but currently, embodiment of insect-like visual systems is limited by the hardware systems available. Suitable hardware is either prohibitively expensive, difficult to reproduce, cannot accurately simulate insect vision characteristics, and/or is too heavy for small robotic platforms. These limitations hamper the development of platforms for embodiment which in turn hampers the progress on understanding of how biological systems fundamentally work. To address this gap, this paper proposes an inexpensive, lightweight robotic system for modelling insect vision. The system is mounted and tested on a robotic platform for mobile applications, and then the camera and insect vision models are evaluated. We analyse the potential of the system for use in embodiment of higher-level visual processes (i.e. motion detection) and also for development of navigation based on vision for robotics in general. Optic flow from sample camera data is calculated and compared to a perfect, simulated bee world showing an excellent resemblance. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Analysis of user characteristics related to drop-off detection with long cane

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Curtis, Amy

    2010-01-01

    This study examined how user characteristics affect drop-off detection with the long cane. A mixed-measures design with block randomization was used for the study, in which 32 visually impaired adults attempted to detect the drop-offs using different cane techniques. Younger cane users detected drop-offs significantly more reliably (mean +/− standard deviation = 74.2% +/− 11.2% of the time) than older cane users (60.9% +/− 10.8%), p = 0.009. The drop-off detection threshold of the younger participants (5.2 +/− 2.1 cm) was also statistically significantly smaller than that of the older participants (7.9 +/− 2.2 cm), p = 0.007. Those with early-onset visual impairment (78.0% +/− 9.0%) also detected drop-offs significantly more reliably than those with later-onset visual impairment (67.3% +/− 12.4%), p = 0.01. No interaction occurred between examined user characteristics (age and age at onset of visual impairment) and the type of cane technique used in drop-off detection. The findings of the study may help orientation and mobility specialists select appropriate cane techniques in accordance with the cane user’s age and onset of visual impairment. PMID:20665349

  13. Temporal Structure and Complexity Affect Audio-Visual Correspondence Detection

    PubMed Central

    Denison, Rachel N.; Driver, Jon; Ruff, Christian C.

    2013-01-01

    Synchrony between events in different senses has long been considered the critical temporal cue for multisensory integration. Here, using rapid streams of auditory and visual events, we demonstrate how humans can use temporal structure (rather than mere temporal coincidence) to detect multisensory relatedness. We find psychophysically that participants can detect matching auditory and visual streams via shared temporal structure for crossmodal lags of up to 200 ms. Performance on this task reproduced features of past findings based on explicit timing judgments but did not show any special advantage for perfectly synchronous streams. Importantly, the complexity of temporal patterns influences sensitivity to correspondence. Stochastic, irregular streams – with richer temporal pattern information – led to higher audio-visual matching sensitivity than predictable, rhythmic streams. Our results reveal that temporal structure and its complexity are key determinants for human detection of audio-visual correspondence. The distinctive emphasis of our new paradigms on temporal patterning could be useful for studying special populations with suspected abnormalities in audio-visual temporal perception and multisensory integration. PMID:23346067

  14. Corneal Complications And Visual Impairment In Vernal Keratoconjunctivitis Patients.

    PubMed

    Arif, Abdus Salam; Aaqil, Bushra; Siddiqui, Afsheen; Nazneen, Zainab; Farooq, Umer

    2017-01-01

    Vernal kerato-conjunctivitis (VKC) is an infrequent but serious form of allergic conjunctivitis common in warm and humid areas where air is rich in allergens. It affects both eyes asymmetrically. Although VKC is a self-limiting disease but visions affecting corneal complications influence the quality of life in school children. The aim of this study was to list the corneal complications due to this condition and to find out the extent of visual impairment among VKC patients. This cross-sectional study was conducted in the department of Ophthalmology, Benazir Bhutto Shaheed Hospital on 290 eyes of diagnosed cases of VKC. The diagnosis of VKC was made on the basis of history and examination. Visual acuity was recorded using Snellen's notation and visual impairment was classified according to World Health Organization classification for visual disabilities. The mean age of presentation was 10.83±6.13 years. There were 207 (71.4%) males and 83 (28.6%) females. Corneal scarring was observed in 59 (20.3%) eyes. Keratoconus was found to be in 17 (5.9%) eyes. Shield ulcer was detected in 09 (3.1%) eyes while 07 (2.4%) eyes had corneal neovascularization. Majority of the patients with visual loss had corneal scarring and the complication that led to severe visual loss in most of the eyes was Keratoconus. Vernal kerato-conjunctivitis in the presence of corneal complications is a sight threatening disease and can lead to severe visual impairment.

  15. Directed Forgetting and Directed Remembering in Visual Working Memory

    PubMed Central

    Williams, Melonie; Woodman, Geoffrey F.

    2013-01-01

    A defining characteristic of visual working memory is its limited capacity. This means that it is crucial to maintain only the most relevant information in visual working memory. However, empirical research is mixed as to whether it is possible to selectively maintain a subset of the information previously encoded into visual working memory. Here we examined the ability of subjects to use cues to either forget or remember a subset of the information already stored in visual working memory. In Experiment 1, participants were cued to either forget or remember one of two groups of colored squares during a change-detection task. We found that both types of cues aided performance in the visual working memory task, but that observers benefited more from a cue to remember than a cue to forget a subset of the objects. In Experiment 2, we show that the previous findings, which indicated that directed-forgetting cues are ineffective, were likely due to the presence of invalid cues that appear to cause observers to disregard such cues as unreliable. In Experiment 3, we recorded event-related potentials (ERPs) and show that an electrophysiological index of focused maintenance is elicited by cues that indicate which subset of information in visual working memory needs to be remembered, ruling out alternative explanations of the behavioral effects of retention-interval cues. The present findings demonstrate that observers can focus maintenance mechanisms on specific objects in visual working memory based on cues indicating future task relevance. PMID:22409182

  16. Development of paper-based sensor coupled with smartphone detector for simple creatinine determination

    NASA Astrophysics Data System (ADS)

    Tambaru, David; Rupilu, Reski Helena; Nitti, Fidelis; Gauru, Imanuel; Suwari

    2017-03-01

    Creatinine level in urine is one of the most important indicators for kidney diseases. A routine assay for this compound is vital especially for those who suffer from kidney malfunction. However, the existing methods are mostly expensive, impractical and time consuming. Here in, we report a research on the development of sensor for creatinine analysis by using cheap materials such as paper and coupled with a smartphone as the detector leading to an inexpensive and free-instrument method. This research was done based on the Jaffe reaction in which the creatinine was reacted with picric acid in basic solution to form an orange-red creatinine-picric complex. The red-green-blue intensity of the complex, captured with a smartphone, was measured and then digitized with free-download Microsoft Visual c# 2010I Express applications, as the analytical response. This proposed method was evaluated based on its precision, accuracy, percent of recovery and limit of detection. It was found that the precision, accuracy, percent of recovery and limit of detection of this method were 5.55%, 0.74 %, 96.73 ± 6.12 % and 8.02 ppm, respectively. It can be concluded that the paper based sensors with digital imaging approach using Microsoft Visual c# 2010I Express,with its simplicity and affordabilitycan be applied for on-site determination of creatinine level.

  17. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    PubMed

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  18. Advanced Augmented White Cane with obstacle height and distance feedback.

    PubMed

    Pyun, Rosali; Kim, Yeongmi; Wespe, Pascal; Gassert, Roger; Schneller, Stefan

    2013-06-01

    The white cane is a widely used mobility aid that helps visually impaired people navigate the surroundings. While it reliably and intuitively extends the detection range of ground-level obstacles and drop-offs to about 1.2 m, it lacks the ability to detect trunk and head-level obstacles. Electronic Travel Aids (ETAs) have been proposed to overcome these limitations, but have found minimal adoption due to limitations such as low information content and low reliability thereof. Although existing ETAs extend the sensing range beyond that of the conventional white cane, most of them do not detect head-level obstacles and drop-offs, nor can they identify the vertical extent of obstacles. Furthermore, some ETAs work independent of the white cane, and thus reliable detection of surface textures and drop-offs is not provided. This paper introduces a novel ETA, the Advanced Augmented White Cane, which detects obstacles at four vertical levels and provides multi-sensory feedback. We evaluated the device in five blindfolded subjects through reaction time measurements following the detection of an obstacle, as well as through the reliability of dropoff detection. The results showed that our aid could help the user successfully detect an obstacle and identify its height, with an average reaction time of 410 msec. Drop-offs were reliably detected with an intraclass correlation > 0.95. This work is a first step towards a low-cost ETA to complement the functionality of the conventional white cane.

  19. Electrophysiological Correlates of Automatic Visual Change Detection in School-Age Children

    ERIC Educational Resources Information Center

    Clery, Helen; Roux, Sylvie; Besle, Julien; Giard, Marie-Helene; Bruneau, Nicole; Gomot, Marie

    2012-01-01

    Automatic stimulus-change detection is usually investigated in the auditory modality by studying Mismatch Negativity (MMN). Although the change-detection process occurs in all sensory modalities, little is known about visual deviance detection, particularly regarding the development of this brain function throughout childhood. The aim of the…

  20. Swept-source based, single-shot, multi-detectable velocity range Doppler optical coherence tomography

    PubMed Central

    Meemon, Panomsak; Rolland, Jannick P.

    2010-01-01

    Phase-Resolved Doppler Optical Coherence Tomography (PR-DOCT) allows visualization and characterization of the location, direction, velocity, and profile of flow activity embedded in a static sample structure. The detectable Velocity Dynamic Range (VDR) of each particular PR-DOCT system is governed by a detectable Doppler phase shift, a flow angle, and an acquisition time interval used to determine the Doppler phase shift. In general, the lower boundary of the detectable Doppler phase shift is limited by the phase stability of the system, while the upper boundary is limited by the π phase ambiguity. For a given range of detectable Doppler phase shift, shortening the acquisition duration will increase not only the maximum detectable velocity but unfortunately also the minimum detectable velocity, which may lead to the invisibility of a slow flow. In this paper, we present an alternative acquisition scheme for PR-DOCT that extends the lower limit of the velocity dynamic range, while maintaining the maximum detectable velocity, hence increasing the overall VDR of PR-DOCT system. The essence of the approach is to implement a technique of multi-scale measurement to simultaneously acquire multiple VDRs in a single measurement. We demonstrate an example of implementation of the technique in a dual VDR DOCT, where two Doppler maps having different detectable VDRs were simultaneously detected, processed, and displayed in real time. One was a fixed VDR DOCT capable of measuring axial velocity of up to 10.9 mm/s without phase unwrapping. The other was a variable VDR DOCT capable of adjusting its detectable VDR to reveal slow flow information down to 11.3 μm/s. The technique is shown to effectively extend the overall detectable VDR of the PR-DOCT system. Examples of real time Doppler imaging of an African frog tadpole are demonstrated using the dual-VDR DOCT system. PMID:21258521

  1. How Many Subjects are Needed for a Visual Field Normative Database? A Comparison of Ground Truth and Bootstrapped Statistics.

    PubMed

    Phu, Jack; Bui, Bang V; Kalloniatis, Michael; Khuu, Sieu K

    2018-03-01

    The number of subjects needed to establish the normative limits for visual field (VF) testing is not known. Using bootstrap resampling, we determined whether the ground truth mean, distribution limits, and standard deviation (SD) could be approximated using different set size ( x ) levels, in order to provide guidance for the number of healthy subjects required to obtain robust VF normative data. We analyzed the 500 Humphrey Field Analyzer (HFA) SITA-Standard results of 116 healthy subjects and 100 HFA full threshold results of 100 psychophysically experienced healthy subjects. These VFs were resampled (bootstrapped) to determine mean sensitivity, distribution limits (5th and 95th percentiles), and SD for different ' x ' and numbers of resamples. We also used the VF results of 122 glaucoma patients to determine the performance of ground truth and bootstrapped results in identifying and quantifying VF defects. An x of 150 (for SITA-Standard) and 60 (for full threshold) produced bootstrapped descriptive statistics that were no longer different to the original distribution limits and SD. Removing outliers produced similar results. Differences between original and bootstrapped limits in detecting glaucomatous defects were minimized at x = 250. Ground truth statistics of VF sensitivities could be approximated using set sizes that are significantly smaller than the original cohort. Outlier removal facilitates the use of Gaussian statistics and does not significantly affect the distribution limits. We provide guidance for choosing the cohort size for different levels of error when performing normative comparisons with glaucoma patients.

  2. Stimulus discriminability in visual search.

    PubMed

    Verghese, P; Nakayama, K

    1994-09-01

    We measured the probability of detecting the target in a visual search task, as a function of the following parameters: the discriminability of the target from the distractors, the duration of the display, and the number of elements in the display. We examined the relation between these parameters at criterion performance (80% correct) to determine if the parameters traded off according to the predictions of a limited capacity model. For the three dimensions that we studied, orientation, color, and spatial frequency, the observed relationship between the parameters deviates significantly from a limited capacity model. The data relating discriminability to display duration are better than predicted over the entire range of orientation and color differences that we examined, and are consistent with the prediction for only a limited range of spatial frequency differences--from 12 to 23%. The relation between discriminability and number varies considerably across the three dimensions and is better than the limited capacity prediction for two of the three dimensions that we studied. Orientation discrimination shows a strong number effect, color discrimination shows almost no effect, and spatial frequency discrimination shows an intermediate effect. The different trading relationships in each dimension are more consistent with early filtering in that dimension, than with a common limited capacity stage. Our results indicate that higher-level processes that group elements together also play a strong role. Our experiments provide little support for limited capacity mechanisms over the range of stimulus differences that we examined in three different dimensions.

  3. Sensitive naked eye detection and quantification assay for nitrite by a fluorescence probe in various water resources.

    PubMed

    Zhang, Fengyuan; Zhu, Xinyue; Jiao, Zhijuan; Liu, Xiaoyan; Zhang, Haixia

    2018-07-05

    An uncontrolled increase of nitrite concentration in groundwater, rivers and lakes is a growing threat to public health and environment. It is important to monitor the nitrite levels in water and clinical diagnosis. Herein, we developed a switch-off fluorescence probe (PyI) for the sensitive detection of nitrite ions in the aqueous media. This probe selectively recognizes nitrite ions through a distinct visual color change from colorless to pink with a detection limit of 0.1 μM. This method has been successfully applied to the determination of nitrites in tap water, lake water and Yellow River water with recoveries in the range of 94.8%-105.4%. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. A comparison of signal detection theory to the objective threshold/strategic model of unconscious perception.

    PubMed

    Haase, Steven J; Fisk, Gary D

    2011-08-01

    A key problem in unconscious perception research is ruling out the possibility that weak conscious awareness of stimuli might explain the results. In the present study, signal detection theory was compared with the objective threshold/strategic model as explanations of results for detection and identification sensitivity in a commonly used unconscious perception task. In the task, 64 undergraduate participants detected and identified one of four briefly displayed, visually masked letters. Identification was significantly above baseline (i.e., proportion correct > .25) at the highest detection confidence rating. This result is most consistent with signal detection theory's continuum of sensory states and serves as a possible index of conscious perception. However, there was limited support for the other model in the form of a predicted "looker's inhibition" effect, which produced identification performance that was significantly below baseline. One additional result, an interaction between the target stimulus and type of mask, raised concerns for the generality of unconscious perception effects.

  5. Dysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis.

    PubMed

    Tu, Joanna H; Foote, Katharina G; Lujan, Brandon J; Ratnam, Kavitha; Qin, Jia; Gorin, Michael B; Cunningham, Emmett T; Tuten, William S; Duncan, Jacque L; Roorda, Austin

    2017-09-01

    Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. A patient diagnosed with acute bilateral foveolitis had spectral-domain optical coherence tomography (SD-OCT) (Spectralis HRA + OCT system [Heidelberg Engineering, Vista, CA, USA]) images indicating focal loss of the inner segment-outer segment junction band with an intact, but hyper-reflective, external limiting membrane. Five years after symptom onset, visual acuity had improved from 20/80 to 20/25, but the retinal appearance remained unchanged compared to 3 months after symptoms began. We performed structural assessments using SD-OCT, directional OCT (non-standard use of a prototype on loan from Carl Zeiss Meditec) and AOSLO (custom-built system). We also administered fundus-referenced functional tests in the region of apparent cone loss, including analysis of preferred retinal locus (PRL), AOSLO acuity, and microperimetry with tracking SLO (TSLO) (prototype system). To determine AOSLO-corrected visual acuity, the scanning laser was modulated with a tumbling E consistent with 20/30 visual acuity. Visual sensitivity was assessed in and around the lesion using TSLO microperimetry. Complete eye examination, including standard measures of best-corrected visual acuity, visual field tests, color fundus photos, and fundus auto-fluorescence were also performed. Despite a lack of visible cone profiles in the foveal lesion, fundus-referenced vision testing demonstrated visual function within the lesion consistent with cone function. The PRL was within the lesion of apparent cone loss at the fovea. AOSLO visual acuity tests were abnormal, but measurable: for trials in which the stimulus remained completely within the lesion, the subject got 48% correct, compared to 78% correct when the stimulus was outside the lesion. TSLO microperimetry revealed reduced, but detectible, sensitivity thresholds within the lesion. Fundus-referenced visual testing proved useful to identify functional cones despite apparent photoreceptor loss identified using AOSLO and SD-OCT. While AOSLO and SD-OCT appear to be sensitive for the detection of abnormal or absent photoreceptors, changes in photoreceptors that are identified with these imaging tools do not correlate completely with visual function in every patient. Fundus-referenced vision testing is a useful tool to indicate the presence of cones that may be amenable to recovery or response to experimental therapies despite not being visible on confocal AOSLO or SD-OCT images.

  6. Sensitive detection of oversulfated chondroitin sulfate in heparin sodium or crude heparin with a colorimetric microplate based assay.

    PubMed

    Sommers, Cynthia D; Mans, Daniel J; Mecker, Laura C; Keire, David A

    2011-05-01

    In this work we describe a 96-well microplate assay for oversulfated chondroitin sulfate A (OSCS) in heparin, based on a water-soluble cationic polythiophene polymer (3-(2-(N-(N'-methylimidazole))ethoxy)-4-methylthiophene (LPTP)) and heparinase digestion of heparin. The assay takes advantage of several unique properties of heparin, OSCS, and LPTP, including OSCS inhibition of heparinase I and II activity, the molecular weight dependence of heparin-LPTP spectral shifts, and the distinct association of heparin fragments and OSCS to LPTP. These factors combine to enable detection of the presence of 0.003% w/w spiked OSCS in 10 μg of heparin sodium active pharmaceutical ingredient (API) using a plate reader and with visual detection to 0.1% levels. The same detection limit for OSCS was observed in the presence of 10% levels of dermatan sulfate (DS) or chondroitin sulfate A (CSA) impurities. In addition, we surveyed a selection of crude heparin samples received by the agency in 2008 and 2009 to determine average and extreme DS, CSA, and galactosamine weight percent levels. In the presence of these impurities and the variable heparin content in the crude heparin samples, spiked OSCS was reliably detected to the 0.1% w/w level using a plate reader. Finally, authentically OSCS contaminated heparin sodium API and crude samples were distinguished visually by color from control samples using the LPTP/heparinase test.

  7. The relationship of global form and motion detection to reading fluency.

    PubMed

    Englund, Julia A; Palomares, Melanie

    2012-08-15

    Visual motion processing in typical and atypical readers has suggested aspects of reading and motion processing share a common cortical network rooted in dorsal visual areas. Few studies have examined the relationship between reading performance and visual form processing, which is mediated by ventral cortical areas. We investigated whether reading fluency correlates with coherent motion detection thresholds in typically developing children using random dot kinematograms. As a comparison, we also evaluated the correlation between reading fluency and static form detection thresholds. Results show that both dorsal and ventral visual functions correlated with components of reading fluency, but that they have different developmental characteristics. Motion coherence thresholds correlated with reading rate and accuracy, which both improved with chronological age. Interestingly, when controlling for non-verbal abilities and age, reading accuracy significantly correlated with thresholds for coherent form detection but not coherent motion detection in typically developing children. Dorsal visual functions that mediate motion coherence seem to be related maturation of broad cognitive functions including non-verbal abilities and reading fluency. However, ventral visual functions that mediate form coherence seem to be specifically related to accurate reading in typically developing children. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Sustained change blindness to incremental scene rotation: a dissociation between explicit change detection and visual memory.

    PubMed

    Hollingworth, Andrew; Henderson, John M

    2004-07-01

    In a change detection paradigm, the global orientation of a natural scene was incrementally changed in 1 degree intervals. In Experiments 1 and 2, participants demonstrated sustained change blindness to incremental rotation, often coming to consider a significantly different scene viewpoint as an unchanged continuation of the original view. Experiment 3 showed that participants who failed to detect the incremental rotation nevertheless reliably detected a single-step rotation back to the initial view. Together, these results demonstrate an important dissociation between explicit change detection and visual memory. Following a change, visual memory is updated to reflect the changed state of the environment, even if the change was not detected.

  9. Rapid visual detection of Mycobacterium avium subsp. paratuberculosis by recombinase polymerase amplification combined with a lateral flow dipstick

    PubMed Central

    Zhao, Guimin; Wang, Hongmei; Hou, Peili; He, Chengqiang

    2018-01-01

    Paratuberculosis (Johne's disease) is a chronic debilitating disease of domestic and wild ruminants. However, widespread point-of-care testing is infrequent due to the lack of a robust method. The isothermal recombinase polymerase amplification (RPA) technique has applied for rapid diagnosis. Herein, RPA combined with a lateral flow dipstick (LFD) assay was developed to estimate DNA from Mycobacterium avium subsp. paratuberculosis. First, analytical specificity and sensitivity of the RPA-nfo primer and probe sets were assessed. The assay successfully detected M. paratuberculosis DNA in 30 min at 39℃ with a detection limit of up to eight copies per reaction, which was equivalent to that of the real-time quantitative polymerase chain reaction (qPCR) assay. The assay was specific, as it did not amplify genomes from five other Mycobacterium spp. or five pathogenic enteric bacteria. Six hundred-twelve clinical samples (320 fecal and 292 serum) were assessed by RPA-LFD, qPCR, and enzyme-linked immunosorbent assay, respectively. The RPA-LFD assay yielded 100% sensitivity, 97.63% specificity, and 98.44% concordance rate with the qPCR results. This is the first report utilizing an RPA-LFD assay to visualize and rapidly detect M. paratuberculosis. Our results show this assay should be a useful method for the diagnosis of paratuberculosis in resource-constrained settings. PMID:29284204

  10. Rapid visual detection of Mycobacterium avium subsp. paratuberculosis by recombinase polymerase amplification combined with a lateral flow dipstick.

    PubMed

    Zhao, Guimin; Wang, Hongmei; Hou, Peili; He, Chengqiang; He, Hongbin

    2018-03-31

    Paratuberculosis (Johne's disease) is a chronic debilitating disease of domestic and wild ruminants. However, widespread point-of-care testing is infrequent due to the lack of a robust method. The isothermal recombinase polymerase amplification (RPA) technique has applied for rapid diagnosis. Herein, RPA combined with a lateral flow dipstick (LFD) assay was developed to estimate DNA from Mycobacterium avium subsp. paratuberculosis . First, analytical specificity and sensitivity of the RPA-nfo primer and probe sets were assessed. The assay successfully detected M. paratuberculosis DNA in 30 min at 39°C with a detection limit of up to eight copies per reaction, which was equivalent to that of the real-time quantitative polymerase chain reaction (qPCR) assay. The assay was specific, as it did not amplify genomes from five other Mycobacterium spp. or five pathogenic enteric bacteria. Six hundred-twelve clinical samples (320 fecal and 292 serum) were assessed by RPA-LFD, qPCR, and enzyme-linked immunosorbent assay, respectively. The RPA-LFD assay yielded 100% sensitivity, 97.63% specificity, and 98.44% concordance rate with the qPCR results. This is the first report utilizing an RPA-LFD assay to visualize and rapidly detect M. paratuberculosis . Our results show this assay should be a useful method for the diagnosis of paratuberculosis in resource-constrained settings.

  11. A Computational Model of Spatial Visualization Capacity

    ERIC Educational Resources Information Center

    Lyon, Don R.; Gunzelmann, Glenn; Gluck, Kevin A.

    2008-01-01

    Visualizing spatial material is a cornerstone of human problem solving, but human visualization capacity is sharply limited. To investigate the sources of this limit, we developed a new task to measure visualization accuracy for verbally-described spatial paths (similar to street directions), and implemented a computational process model to…

  12. The role of ecological factors in shaping bat cone opsin evolution.

    PubMed

    Gutierrez, Eduardo de A; Schott, Ryan K; Preston, Matthew W; Loureiro, Lívia O; Lim, Burton K; Chang, Belinda S W

    2018-04-11

    Bats represent one of the largest and most striking nocturnal mammalian radiations, exhibiting many visual system specializations for performance in light-limited environments. Despite representing the greatest ecological diversity and species richness in Chiroptera, Neotropical lineages have been undersampled in molecular studies, limiting the potential for identifying signatures of selection on visual genes associated with differences in bat ecology. Here, we investigated how diverse ecological pressures mediate long-term shifts in selection upon long-wavelength ( Lws ) and short-wavelength ( Sws1 ) opsins, photosensitive cone pigments that form the basis of colour vision in most mammals, including bats. We used codon-based likelihood clade models to test whether ecological variables associated with reliance on visual information (e.g. echolocation ability and diet) or exposure to varying light environments (e.g. roosting behaviour and foraging habitat) mediated shifts in evolutionary rates in bat cone opsin genes. Using additional cone opsin sequences from newly sequenced eye transcriptomes of six Neotropical bat species, we found significant evidence for different ecological pressures influencing the evolution of the cone opsins. While Lws is evolving under significantly lower constraint in highly specialized high-duty cycle echolocating lineages, which have enhanced sonar ability to detect and track targets, variation in Sws1 constraint was significantly associated with foraging habitat, exhibiting elevated rates of evolution in species that forage among vegetation. This suggests that increased reliance on echolocation as well as the spectral environment experienced by foraging bats may differentially influence the evolution of different cone opsins. Our study demonstrates that different ecological variables may underlie contrasting evolutionary patterns in bat visual opsins, and highlights the suitability of clade models for testing ecological hypotheses of visual evolution. © 2018 The Author(s).

  13. Bridging the Host-Network Divide: Survey, Taxonomy, and Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fink, Glenn A.; Duggirala, Vedavyas; Correa, Ricardo

    2007-04-17

    Abstract: "This paper presents a new direction in security awareness tools for system administration--the Host-Network (HoNe) Visualizer. Our requirements for the HoNe Visualizer come from needs system administrators expressed in interviews, from reviewing the literature, and from conducting usability studies with prototypes. We present a tool taxonomy that serves as a framework for our literature review, and we use the taxonomy to show what is missing in the administrator's arsenal. Then we unveil our tool and its supporting infrastructure that we believe will fill the empty niche. We found that most security tools provide either an internal view of amore » host or an external view of traffic on a network. Our interviewees revealed how they must construct a mental end-to-end view from separate tools that individually give an incomplete view, expending valuable time and mental effort. Because of limitations designed into TCP/IP [RFC-791, RFC-793], no tool can effectively correlate host and network data into an end-to-end view without kernel modifications. Currently, no other visualization exists to support end-to-end analysis. But HoNe's infrastructure overcomes TCP/IP's limitations bridging the network and transport layers in the network stack and making end-to-end correlation possible. The capstone is the HoNe Visualizer that amplifies the users' cognitive power and reduces their mental workload by illustrating the correlated data graphically. Users said HoNe would be particularly good for discovering day-zero exploits. Our usability study revealed that users performed better on intrusion detection tasks using our visualization than with tools they were accustomed to using regardless of their experience level."« less

  14. Task Demands Control Acquisition and Storage of Visual Information

    ERIC Educational Resources Information Center

    Droll, Jason A.; Hayhoe, Mary M.; Triesch, Jochen; Sullivan, Brian T.

    2005-01-01

    Attention and working memory limitations set strict limits on visual representations, yet researchers have little appreciation of how these limits constrain the acquisition of information in ongoing visually guided behavior. Subjects performed a brick sorting task in a virtual environment. A change was made to 1 of the features of the brick being…

  15. Development of a rapid assay for the diagnosis of Myxobolus cerebralis in fish and oligochaetes using loop-mediated isothermal amplification.

    PubMed

    El-Matbouli, M; Soliman, H

    2005-09-01

    A loop-mediated isothermal amplification assay was developed for the rapid detection of Myxobolus cerebralis in both fish and oligochaete hosts. The assay was optimized to amplify parasitic DNA by incubation with Bst DNA polymerase and a set of six specially constructed primers at 65 degrees C for 60 min. The amplification products were detected visually using SYBR Green I dye which gave identical results to gel electrophoresis analysis. Parasite DNA was detected from infected oligochaetes, and from the anal fin, caudal fin, dorsal fin and operculum of clinically infected fish. This 'Myxo-LAMP' assay has a detection limit similar to that of a polymerase chain reaction assay (10(-6)), but is more rapid and only requires a water bath for amplification and is therefore practical for simple and rapid diagnosis of infected tissue.

  16. [Coronary artery disease and cardiac ischemic disease: two different pathologies with different diagnostic procedures].

    PubMed

    Vallejo, Enrique

    2009-01-01

    Coronary artery disease (CAD) remains the leading cause of death in the Western world, and early detection of CAD allows optimal therapeutic management. The gold standard has always been invasive coronary angiography, but over the years various non-invasive techniques have been developed to detect CAD, including cardiac SPECT and cardiac computed tomography (Cardiac CT). Cardiac SPECT permitted visualization of myocardial perfusion and have focused on the assessment of the hemodynamic consequences of obstructive coronary lesions as a marker of CAD. Cardiac CT focuses on the detection of atherosclerosis rather than ischemia, and permit detection of CAD at an earlier stage. Objectives of this manuscript are to discuss the clinical experience with both modalities and to provide a critical review of the strengths and limitations of Cardiac SPECT and Cardiac CT for the diagnostic and management of patients with suspected CAD or cardiac ischemic disease.

  17. Rapid Detection of Prunus Necrotic Ringspot Virus by Reverse Transcription-cross-priming Amplification Coupled with Nucleic Acid Test Strip Cassette.

    PubMed

    Huo, Ya-Yun; Li, Gui-Fen; Qiu, Yan-Hong; Li, Wei-Min; Zhang, Yong-Jiang

    2017-11-23

    Prunus necrotic ringspot virus (PNRSV) is one of the most devastating viruses to Prunus spp. In this study, we developed a diagnostic system RT-CPA-NATSC, wherein reverse transcription-cross-priming amplification (RT-CPA) is coupled with nucleic acid test strip cassette (NATSC), a vertical flow (VF) visualization, for PNRSV detection. The RT-CPA-NATSC assay targets the encoding gene of the PNRSV coat protein with a limit of detection of 72 copies per reaction and no cross-reaction with the known Prunus pathogenic viruses and viroids, demonstrating high sensitivity and specificity. The reaction is performed on 60 °C and can be completed less than 90 min with the prepared template RNA. Field sample test confirmed the reliability of RT-CPA-NATSC, indicating the potential application of this simple and rapid detection method in routine test of PNRSV.

  18. Investigating the visual span in comparative search: the effects of task difficulty and divided attention.

    PubMed

    Pomplun, M; Reingold, E M; Shen, J

    2001-09-01

    In three experiments, participants' visual span was measured in a comparative visual search task in which they had to detect a local match or mismatch between two displays presented side by side. Experiment 1 manipulated the difficulty of the comparative visual search task by contrasting a mismatch detection task with a substantially more difficult match detection task. In Experiment 2, participants were tested in a single-task condition involving only the visual task and a dual-task condition in which they concurrently performed an auditory task. Finally, in Experiment 3, participants performed two dual-task conditions, which differed in the difficulty of the concurrent auditory task. Both the comparative search task difficulty (Experiment 1) and the divided attention manipulation (Experiments 2 and 3) produced strong effects on visual span size.

  19. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    PubMed

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Pathological findings in retina and visual pathways associated to natural Scrapie in sheep.

    PubMed

    Hortells, Paloma; Monzón, Marta; Monleón, Eva; Acín, Cristina; Vargas, Antonia; Bolea, Rosa; Luján, Lluís; Badiola, Juan José

    2006-09-07

    This work represents a comprehensive pathological description of the retina and visual pathways in naturally affected Scrapie sheep. Twenty naturally affected Scrapie sheep and 6 matched controls were used. Eyes, optic nerves and brain from each animal were fixed and histologically processed using hematoxylin-eosin, followed by immunohistochemical staining for prion protein (PrPsc) and glial fibrillar acidic protein (GFAP). Retinal histopathological changes were observed in only 7 clinically affected animals and mainly consisted of loss of outer limitant layer definition, outer plexiform layer atrophy, disorganization and loss of nuclei in both nuclear layers, and Müller glia hypertrophy. PrPsc was detected in the retina of 19 of the 20 sheep and characterized by a disseminated granular deposit across layers and intraneuronally in ganglion cells. The inner plexiform and the ganglion cell layers were the structures most severely affected by PrPsc deposits. PrPsc exhibited a tendency to spread from these two layers to the others. A marked increase in the number and intensity of GFAP-expressing Müller cells was observed in the clinical stage, especially at the terminal stage of the disease. Spongiosis and PrPsc were detected within the visual pathways at the preclinical stage, their values increasing during the course of the disease but varying between the areas examined. PrPsc was detected in only 3 optic nerves. The results suggest that the presence of PrPsc in the retina correlates with disease progression during the preclinical and clinical stages, perhaps using the inner plexiform layer as a first entry site and diffusing from the brain using a centrifugal model.

  1. A novel boundary layer sensor utilizing domain switching in ferroelectric liquid crystals

    NASA Technical Reports Server (NTRS)

    Parmar, D. S.

    1991-01-01

    This paper describes the design and the principles of operation of a novel sensor for the optical detection of a shear stress field induced by air or gas flow on a rigid surface. The detection relies on the effects of shear-induced optical switching in ferroelectric liquid crystals. It is shown that the method overcomes many of the limitations of similar measuring techniques including those using cholesteric liquid crystals. The present method offers a preferred alternative for flow visualization and skin friction measurements in wind-tunnel experiments on laminar boundary layer transition investigations. A theoretical model for the optical response to shear stress is presented together with a schematic diagram of the experimental setup.

  2. Towards real-time medical diagnostics using hyperspectral imaging technology

    NASA Astrophysics Data System (ADS)

    Bjorgan, Asgeir; Randeberg, Lise L.

    2015-07-01

    Hyperspectral imaging provides non-contact, high resolution spectral images which has a substantial diagnostic potential. This can be used for e.g. diagnosis and early detection of arthritis in finger joints. Processing speed is currently a limitation for clinical use of the technique. A real-time system for analysis and visualization using GPU processing and threaded CPU processing is presented. Images showing blood oxygenation, blood volume fraction and vessel enhanced images are among the data calculated in real-time. This study shows the potential of real-time processing in this context. A combination of the processing modules will be used in detection of arthritic finger joints from hyperspectral reflectance and transmittance data.

  3. Feedforward and recurrent processing in scene segmentation: electroencephalography and functional magnetic resonance imaging.

    PubMed

    Scholte, H Steven; Jolij, Jacob; Fahrenfort, Johannes J; Lamme, Victor A F

    2008-11-01

    In texture segregation, an example of scene segmentation, we can discern two different processes: texture boundary detection and subsequent surface segregation [Lamme, V. A. F., Rodriguez-Rodriguez, V., & Spekreijse, H. Separate processing dynamics for texture elements, boundaries and surfaces in primary visual cortex of the macaque monkey. Cerebral Cortex, 9, 406-413, 1999]. Neural correlates of texture boundary detection have been found in monkey V1 [Sillito, A. M., Grieve, K. L., Jones, H. E., Cudeiro, J., & Davis, J. Visual cortical mechanisms detecting focal orientation discontinuities. Nature, 378, 492-496, 1995; Grosof, D. H., Shapley, R. M., & Hawken, M. J. Macaque-V1 neurons can signal illusory contours. Nature, 365, 550-552, 1993], but whether surface segregation occurs in monkey V1 [Rossi, A. F., Desimone, R., & Ungerleider, L. G. Contextual modulation in primary visual cortex of macaques. Journal of Neuroscience, 21, 1698-1709, 2001; Lamme, V. A. F. The neurophysiology of figure ground segregation in primary visual-cortex. Journal of Neuroscience, 15, 1605-1615, 1995], and whether boundary detection or surface segregation signals can also be measured in human V1, is more controversial [Kastner, S., De Weerd, P., & Ungerleider, L. G. Texture segregation in the human visual cortex: A functional MRI study. Journal of Neurophysiology, 83, 2453-2457, 2000]. Here we present electroencephalography (EEG) and functional magnetic resonance imaging data that have been recorded with a paradigm that makes it possible to differentiate between boundary detection and scene segmentation in humans. In this way, we were able to show with EEG that neural correlates of texture boundary detection are first present in the early visual cortex around 92 msec and then spread toward the parietal and temporal lobes. Correlates of surface segregation first appear in temporal areas (around 112 msec) and from there appear to spread to parietal, and back to occipital areas. After 208 msec, correlates of surface segregation and boundary detection also appear in more frontal areas. Blood oxygenation level-dependent magnetic resonance imaging results show correlates of boundary detection and surface segregation in all early visual areas including V1. We conclude that texture boundaries are detected in a feedforward fashion and are represented at increasing latencies in higher visual areas. Surface segregation, on the other hand, is represented in "reverse hierarchical" fashion and seems to arise from feedback signals toward early visual areas such as V1.

  4. Making the invisible visible: verbal but not visual cues enhance visual detection.

    PubMed

    Lupyan, Gary; Spivey, Michael J

    2010-07-07

    Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d'). A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception.

  5. Intravital phosphorescence lifetime imaging of the renal cortex accurately measures renal hypoxia.

    PubMed

    Hirakawa, Yosuke; Mizukami, Kiichi; Yoshihara, Toshitada; Takahashi, Ippei; Khulan, Purevsuren; Honda, Tomoko; Mimura, Imari; Tanaka, Tetsuhiro; Tobita, Seiji; Nangaku, Masaomi

    2018-06-01

    Renal tubulointerstitial hypoxia is recognized as a final common pathway of chronic kidney disease and is considered a promising drug target. However, hypoxia in the tubules is not well examined because of limited detection methods. Here, we devised a method to visualize renal tubular oxygen tension with spatial resolution at a cellular level using the cell-penetrating phosphorescent probe, BTPDM1 (an iridium-based cationic lipophilic dye), and confocal phosphorescence lifetime imaging microscopy to precisely assess renal hypoxia. Imaging with BTPDM1 revealed an oxygen gradient between S1 and S2 segments in mouse kidney. We also demonstrated that our microscopy system can detect subtle changes of hypoxemia and reoxygenation, and the acquired phosphorescence lifetime can be converted to partial pressure of oxygen. This new method allows, for the first time, visualization of intravital oxygen gradients at the renal surface with high spatial resolution. Thus, the confocal phosphorescence lifetime imaging microscopy platform, combined with BTPDM1, will promote an accurate understanding of tissue hypoxia, including renal hypoxia. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  6. DSPCP: A Data Scalable Approach for Identifying Relationships in Parallel Coordinates.

    PubMed

    Nguyen, Hoa; Rosen, Paul

    2018-03-01

    Parallel coordinates plots (PCPs) are a well-studied technique for exploring multi-attribute datasets. In many situations, users find them a flexible method to analyze and interact with data. Unfortunately, using PCPs becomes challenging as the number of data items grows large or multiple trends within the data mix in the visualization. The resulting overdraw can obscure important features. A number of modifications to PCPs have been proposed, including using color, opacity, smooth curves, frequency, density, and animation to mitigate this problem. However, these modified PCPs tend to have their own limitations in the kinds of relationships they emphasize. We propose a new data scalable design for representing and exploring data relationships in PCPs. The approach exploits the point/line duality property of PCPs and a local linear assumption of data to extract and represent relationship summarizations. This approach simultaneously shows relationships in the data and the consistency of those relationships. Our approach supports various visualization tasks, including mixed linear and nonlinear pattern identification, noise detection, and outlier detection, all in large data. We demonstrate these tasks on multiple synthetic and real-world datasets.

  7. A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.

    PubMed

    Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo

    2012-11-02

    A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Cone beam computed tomography in the diagnosis of dental disease.

    PubMed

    Tetradis, Sotirios; Anstey, Paul; Graff-Radford, Steven

    2011-07-01

    Conventional radiographs provide important information for dental disease diagnosis. However, they represent 2-D images of 3-D objects with significant structure superimposition and unpredictable magnification. Cone beam computed tomography, however, allows true 3-D visualization of the dentoalveolar structures, avoiding major limitations of conventional radiographs. Cone beam computed tomography images offer great advantages in disease detection for selected patients. The authors discuss cone beam computed tomography applications in dental disease diagnosis, reviewing the pertinent literature when available.

  9. iTTVis: Interactive Visualization of Table Tennis Data.

    PubMed

    Wu, Yingcai; Lan, Ji; Shu, Xinhuan; Ji, Chenyang; Zhao, Kejian; Wang, Jiachen; Zhang, Hui

    2018-01-01

    The rapid development of information technology paved the way for the recording of fine-grained data, such as stroke techniques and stroke placements, during a table tennis match. This data recording creates opportunities to analyze and evaluate matches from new perspectives. Nevertheless, the increasingly complex data poses a significant challenge to make sense of and gain insights into. Analysts usually employ tedious and cumbersome methods which are limited to watching videos and reading statistical tables. However, existing sports visualization methods cannot be applied to visualizing table tennis competitions due to different competition rules and particular data attributes. In this work, we collaborate with data analysts to understand and characterize the sophisticated domain problem of analysis of table tennis data. We propose iTTVis, a novel interactive table tennis visualization system, which to our knowledge, is the first visual analysis system for analyzing and exploring table tennis data. iTTVis provides a holistic visualization of an entire match from three main perspectives, namely, time-oriented, statistical, and tactical analyses. The proposed system with several well-coordinated views not only supports correlation identification through statistics and pattern detection of tactics with a score timeline but also allows cross analysis to gain insights. Data analysts have obtained several new insights by using iTTVis. The effectiveness and usability of the proposed system are demonstrated with four case studies.

  10. Learning a visuomotor rotation: simultaneous visual and proprioceptive information is crucial for visuomotor remapping.

    PubMed

    Shabbott, Britne A; Sainburg, Robert L

    2010-05-01

    Visuomotor adaptation is mediated by errors between intended and sensory-detected arm positions. However, it is not clear whether visual-based errors that are shown during the course of motion lead to qualitatively different or more efficient adaptation than errors shown after movement. For instance, continuous visual feedback mediates online error corrections, which may facilitate or inhibit the adaptation process. We addressed this question by manipulating the timing of visual error information and task instructions during a visuomotor adaptation task. Subjects were exposed to a visuomotor rotation, during which they received continuous visual feedback (CF) of hand position with instructions to correct or not correct online errors, or knowledge-of-results (KR), provided as a static hand-path at the end of each trial. Our results showed that all groups improved performance with practice, and that online error corrections were inconsequential to the adaptation process. However, in contrast to the CF groups, the KR group showed relatively small reductions in mean error with practice, increased inter-trial variability during rotation exposure, and more limited generalization across target distances and workspace. Further, although the KR group showed improved performance with practice, after-effects were minimal when the rotation was removed. These findings suggest that simultaneous visual and proprioceptive information is critical in altering neural representations of visuomotor maps, although delayed error information may elicit compensatory strategies to offset perturbations.

  11. The wide window of face detection.

    PubMed

    Hershler, Orit; Golan, Tal; Bentin, Shlomo; Hochstein, Shaul

    2010-08-20

    Faces are detected more rapidly than other objects in visual scenes and search arrays, but the cause for this face advantage has been contested. In the present study, we found that under conditions of spatial uncertainty, faces were easier to detect than control targets (dog faces, clocks and cars) even in the absence of surrounding stimuli, making an explanation based only on low-level differences unlikely. This advantage improved with eccentricity in the visual field, enabling face detection in wider visual windows, and pointing to selective sparing of face detection at greater eccentricities. This face advantage might be due to perceptual factors favoring face detection. In addition, the relative face advantage is greater under flanked than non-flanked conditions, suggesting an additional, possibly attention-related benefit enabling face detection in groups of distracters.

  12. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    PubMed Central

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection. PMID:28690568

  13. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet.

    PubMed

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.

  14. Audio-Visual Perception System for a Humanoid Robotic Head

    PubMed Central

    Viciana-Abad, Raquel; Marfil, Rebeca; Perez-Lorenzo, Jose M.; Bandera, Juan P.; Romero-Garces, Adrian; Reche-Lopez, Pedro

    2014-01-01

    One of the main issues within the field of social robotics is to endow robots with the ability to direct attention to people with whom they are interacting. Different approaches follow bio-inspired mechanisms, merging audio and visual cues to localize a person using multiple sensors. However, most of these fusion mechanisms have been used in fixed systems, such as those used in video-conference rooms, and thus, they may incur difficulties when constrained to the sensors with which a robot can be equipped. Besides, within the scope of interactive autonomous robots, there is a lack in terms of evaluating the benefits of audio-visual attention mechanisms, compared to only audio or visual approaches, in real scenarios. Most of the tests conducted have been within controlled environments, at short distances and/or with off-line performance measurements. With the goal of demonstrating the benefit of fusing sensory information with a Bayes inference for interactive robotics, this paper presents a system for localizing a person by processing visual and audio data. Moreover, the performance of this system is evaluated and compared via considering the technical limitations of unimodal systems. The experiments show the promise of the proposed approach for the proactive detection and tracking of speakers in a human-robot interactive framework. PMID:24878593

  15. Vision improvement in pilots with presbyopia following perceptual learning.

    PubMed

    Sterkin, Anna; Levy, Yuval; Pokroy, Russell; Lev, Maria; Levian, Liora; Doron, Ravid; Yehezkel, Oren; Fried, Moshe; Frenkel-Nir, Yael; Gordon, Barak; Polat, Uri

    2017-11-24

    Israeli Air Force (IAF) pilots continue flying combat missions after the symptoms of natural near-vision deterioration, termed presbyopia, begin to be noticeable. Because modern pilots rely on the displays of the aircraft control and performance instruments, near visual acuity (VA) is essential in the cockpit. We aimed to apply a method previously shown to improve visual performance of presbyopes, and test whether presbyopic IAF pilots can overcome the limitation imposed by presbyopia. Participants were selected by the IAF aeromedical unit as having at least initial presbyopia and trained using a structured personalized perceptual learning method (GlassesOff application), based on detecting briefly presented low-contrast Gabor stimuli, under the conditions of spatial and temporal constraints, from a distance of 40 cm. Our results show that despite their initial visual advantage over age-matched peers, training resulted in robust improvements in various basic visual functions, including static and temporal VA, stereoacuity, spatial crowding, contrast sensitivity and contrast discrimination. Moreover, improvements generalized to higher-level tasks, such as sentence reading and aerial photography interpretation (specifically designed to reflect IAF pilots' expertise in analyzing noisy low-contrast input). In concert with earlier suggestions, gains in visual processing speed are plausible to account, at least partially, for the observed training-induced improvements. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Refractive errors.

    PubMed

    Schiefer, Ulrich; Kraus, Christina; Baumbach, Peter; Ungewiß, Judith; Michels, Ralf

    2016-10-14

    All over the world, refractive errors are among the most frequently occuring treatable distur - bances of visual function. Ametropias have a prevalence of nearly 70% among adults in Germany and are thus of great epidemiologic and socio-economic relevance. In the light of their own clinical experience, the authors review pertinent articles retrieved by a selective literature search employing the terms "ametropia, "anisometropia," "refraction," "visual acuity," and epidemiology." In 2011, only 31% of persons over age 16 in Germany did not use any kind of visual aid; 63.4% wore eyeglasses and 5.3% wore contact lenses. Refractive errors were the most common reason for consulting an ophthalmologist, accounting for 21.1% of all outpatient visits. A pinhole aperture (stenopeic slit) is a suitable instrument for the basic diagnostic evaluation of impaired visual function due to optical factors. Spherical refractive errors (myopia and hyperopia), cylindrical refractive errors (astigmatism), unequal refractive errors in the two eyes (anisometropia), and the typical optical disturbance of old age (presbyopia) cause specific functional limitations and can be detected by a physician who does not need to be an ophthalmologist. Simple functional tests can be used in everyday clinical practice to determine quickly, easily, and safely whether the patient is suffering from a benign and easily correctable type of visual impairment, or whether there are other, more serious underlying causes.

  17. Visual detection technique for efficient screening and isolation of Salmonella based on a novel enrichment assay using chromatography membrane.

    PubMed

    Tang, F; Xiong, Y; Zhang, H; Wu, K; Xiang, Y; Shao, J-B; Ai, H-W; Xiang, Y-P; Zheng, X-L; Lv, J-R; Sun, H; Bao, L-S; Zhang, Z; Hu, H-B; Zhang, J-Y; Chen, L; Lu, J; Liu, W-Y; Mei, H; Ma, Y; Xu, C-F; Fang, A-Y; Gu, M; Xu, C-Y; Chen, Y; Chen, Z; Sun, Z-Y

    2016-03-01

    To detect Salmonella more efficiently and isolate strains more easily, a novel and simple detection method that uses an enrichment assay and two chromogenic reactions on a chromatography membrane was developed. Grade 3 chromatography paper is used as functionalized solid phase support (SPS), which contains specially optimized medium. One reaction for screening is based on the sulfate-reducing capacity of Salmonella. Hydrogen sulfide (H2S) generated by Salmonella reacts with ammonium ferric citrate to produce black colored ferrous sulfide. Another reaction is based on Salmonella C8 esterase that is unique for Enterobacteriaceae except Serratia and interacts with 4-methylumbelliferyl caprylate (MUCAP) to produce fluorescent umbelliferone, which is visible under ultraviolet light. A very low detection limit (10(1) CFU ml(-1)) for Salmonella was achieved on the background of 10(5) CFU ml(-1) Escherichia coli. More importantly, testing with more than 1,000 anal samples indicated that our method has a high positive detection rate and is relatively low cost, compared with the traditional culture-based method. It took only 1 day for the preliminary screening and 2 days to efficiently isolate the Salmonella cells, indicating that the new assay is specific, rapid, and simple for Salmonella detection. In contrast to the traditional culture-based method, this method can be easily used to screen and isolate targeted strains with the naked eye. The results of quantitative and comparative experiments showed that the visual detection technique is an efficient alternative method for the screening of Salmonella spp. in many applications of large-sized samples related to public health surveillance.

  18. Low picomolar, instrument-free visual detection of mercury and silver ions using low-cost programmable nanoprobes

    PubMed Central

    Rana, Muhit; Balcioglu, Mustafa; Robertson, Neil M.; Hizir, Mustafa Salih; Yumak, Sumeyra

    2017-01-01

    The EPA's recommended maximum allowable level of inorganic mercury in drinking water is 2 ppb (10 nM). To our knowledge, the most sensitive colorimetric mercury sensor reported to date has a limit of detection (LOD) of 800 pM. Here, we report an instrument-free and highly practical colorimetric methodology, which enables detection of as low as 2 ppt (10 pM) of mercury and/or silver ions with the naked eye using a gold nanoprobe. Synthesis of the nanoprobe costs less than $1.42, which is enough to perform 200 tests in a microplate; less than a penny for each test. We have demonstrated the detection of inorganic mercury from water, soil and urine samples. The assay takes about four hours and the color change is observed within minutes after the addition of the last required element of the assay. The nanoprobe is highly programmable which allows for the detection of mercury and/or silver ions separately or simultaneously by changing only a single parameter of the assay. This highly sensitive approach for the visual detection relies on the combination of the signal amplification features of the hybridization chain reaction with the plasmonic properties of the gold nanoparticles. Considering that heavy metal ion contamination of natural resources is a major challenge and routine environmental monitoring is needed, yet time-consuming, this colorimetric approach may be instrumental for on-site heavy metal ion detection. Since the color transition can be measured in a variety of formats including using the naked eye, a simple UV-Vis spectrophotometer, or recording using mobile phone apps for future directions, our cost-efficient assay and method have the potential to be translated into the field. PMID:28451261

  19. Improved In vivo Assessment of Pulmonary Fibrosis in Mice using X-Ray Dark-Field Radiography

    NASA Astrophysics Data System (ADS)

    Yaroshenko, Andre; Hellbach, Katharina; Yildirim, Ali Önder; Conlon, Thomas M.; Fernandez, Isis Enlil; Bech, Martin; Velroyen, Astrid; Meinel, Felix G.; Auweter, Sigrid; Reiser, Maximilian; Eickelberg, Oliver; Pfeiffer, Franz

    2015-12-01

    Idiopathic pulmonary fibrosis (IPF) is a chronic and progressive lung disease with a median life expectancy of 4-5 years after initial diagnosis. Early diagnosis and accurate monitoring of IPF are limited by a lack of sensitive imaging techniques that are able to visualize early fibrotic changes at the epithelial-mesenchymal interface. Here, we report a new x-ray imaging approach that directly visualizes the air-tissue interfaces in mice in vivo. This imaging method is based on the detection of small-angle x-ray scattering that occurs at the air-tissue interfaces in the lung. Small-angle scattering is detected with a Talbot-Lau interferometer, which provides the so-called x-ray dark-field signal. Using this imaging modality, we demonstrate-for the first time-the quantification of early pathogenic changes and their correlation with histological changes, as assessed by stereological morphometry. The presented radiography method is significantly more sensitive in detecting morphological changes compared with conventional x-ray imaging, and exhibits a significantly lower radiation dose than conventional x-ray CT. As a result of the improved imaging sensitivity, this new imaging modality could be used in future to reduce the number of animals required for pulmonary research studies.

  20. Single-visit approach of cervical cancer screening: See and Treat in Indonesia

    PubMed Central

    Vet, J N I; Kooijman, J L; Henderson, F C; Aziz, F M; Purwoto, G; Susanto, H; Surya, I G D; Budiningsih, S; Cornain, S; Fleuren, G J; Trimbos, J B; Peters, A A W

    2012-01-01

    Background: We performed a cross-sectional study in Indonesia to evaluate the performance of a single-visit approach of cervical cancer screening, using visual inspection with acetic acid (VIA), histology and cryotherapy in low-resource settings. Methods: Women having limited access to health-care facilities were screened by trained doctors using VIA. If the test was positive, biopsies were taken and when eligible, women were directly treated with cryotherapy. Follow-up was performed with VIA and cytology after 6 months. When cervical cancer was suspected or diagnosed, women were referred. The positivity rate, positive predictive value (PPV) and approximate specificity of the VIA test were calculated. The detection rate for cervical lesions was given. Results: Screening results were completed in 22 040 women, of whom 92.7% had never been screened. Visual inspection with acetic acid was positive in 4.4%. The PPV of VIA to detect CIN I or greater and CIN II or greater was 58.7% and 29.7%, respectively. The approximate specificity was 98.1%, and the detection rate for CIN I or greater was 2.6%. Conclusion: The single-visit approach cervical cancer screening performed well, showing See and Treat is a promising way to reduce cervical cancer in Indonesia. PMID:22850550

  1. Integration of bio-inspired, control-based visual and olfactory data for the detection of an elusive target

    NASA Astrophysics Data System (ADS)

    Duong, Tuan A.; Duong, Nghi; Le, Duong

    2017-01-01

    In this paper, we present an integration technique using a bio-inspired, control-based visual and olfactory receptor system to search for elusive targets in practical environments where the targets cannot be seen obviously by either sensory data. Bio-inspired Visual System is based on a modeling of extended visual pathway which consists of saccadic eye movements and visual pathway (vertebrate retina, lateral geniculate nucleus and visual cortex) to enable powerful target detections of noisy, partial, incomplete visual data. Olfactory receptor algorithm, namely spatial invariant independent component analysis, that was developed based on data of old factory receptor-electronic nose (enose) of Caltech, is adopted to enable the odorant target detection in an unknown environment. The integration of two systems is a vital approach and sets up a cornerstone for effective and low-cost of miniaturized UAVs or fly robots for future DOD and NASA missions, as well as for security systems in Internet of Things environments.

  2. Adaptive Gaze Strategies for Locomotion with Constricted Visual Field

    PubMed Central

    Authié, Colas N.; Berthoz, Alain; Sahel, José-Alain; Safran, Avinoam B.

    2017-01-01

    In retinitis pigmentosa (RP), loss of peripheral visual field accounts for most difficulties encountered in visuo-motor coordination during locomotion. The purpose of this study was to accurately assess the impact of peripheral visual field loss on gaze strategies during locomotion, and identify compensatory mechanisms. Nine RP subjects presenting a central visual field limited to 10–25° in diameter, and nine healthy subjects were asked to walk in one of three directions—straight ahead to a visual target, leftward and rightward through a door frame, with or without obstacle on the way. Whole body kinematics were recorded by motion capture, and gaze direction in space was reconstructed using an eye-tracker. Changes in gaze strategies were identified in RP subjects, including extensive exploration prior to walking, frequent fixations of the ground (even knowing no obstacle was present), of door edges, essentially of the proximal one, of obstacle edge/corner, and alternating door edges fixations when approaching the door. This was associated with more frequent, sometimes larger rapid-eye-movements, larger movements, and forward tilting of the head. Despite the visual handicap, the trajectory geometry was identical between groups, with a small decrease in walking speed in RPs. These findings identify the adaptive changes in sensory-motor coordination, in order to ensure visual awareness of the surrounding, detect changes in spatial configuration, collect information for self-motion, update the postural reference frame, and update egocentric distances to environmental objects. They are of crucial importance for the design of optimized rehabilitation procedures. PMID:28798674

  3. Visual Biopsy by Hydrogen Peroxide-Induced Signal Amplification.

    PubMed

    Zhao, Wenjie; Yang, Sheng; Yang, Jinfeng; Li, Jishan; Zheng, Jing; Qing, Zhihe; Yang, Ronghua

    2016-11-01

    Visual biopsy has attracted special interest by surgeons due to its simplicity and practicality; however, the limited sensitivity of the technology makes it difficult to achieve an early diagnosis. To circumvent this problem, herein, we report a visual signal amplification strategy for establishing a marker-recognizable biopsy that enables early cancer diagnosis. In our proposed approach, hydrogen peroxide (H 2 O 2 ) was selected as a potential underlying marker for its compact relationship in cancer progression. For selective recognition of H 2 O 2 in the process of visual biopsy, a benzylbenzeneboronic acid pinacol ester-decorated copolymer, namely, PMPC-Bpe, was synthesized, affording the final formation of the H 2 O 2 -responsive micelles in which amylose was trapped. The presence of H 2 O 2 activates the boronate ester recognition site and induces it releasing abundant indicator amylose, leading to signal amplification. The indicator came across the solution of KI/I 2 added to the sample, and the formative amylose-KI/I 2 complex has a distinct blue color at 574 nm for visual amplification detection. The feasibility of the proposed method is demonstrated by visualizing the H 2 O 2 content of cancer at different stages and three kinds of actual cancerous samples. As far as we know, this is the first paradigm to rationally design a signaling amplification-based molecular recognizable biopsy for visual and sensitive disease identification, which will extend new possibilities for marker-recognition and signal amplification-based biopsy in disease progressing.

  4. Different effects of executive and visuospatial working memory on visual consciousness.

    PubMed

    De Loof, Esther; Poppe, Louise; Cleeremans, Axel; Gevers, Wim; Van Opstal, Filip

    2015-11-01

    Consciousness and working memory are two widely studied cognitive phenomena. Although they have been closely tied on a theoretical and neural level, empirical work that investigates their relation is largely lacking. In this study, the relationship between visual consciousness and different working memory components is investigated by using a dual-task paradigm. More specifically, while participants were performing a visual detection task to measure their visual awareness threshold, they had to concurrently perform either an executive or visuospatial working memory task. We hypothesized that visual consciousness would be hindered depending on the type and the size of the load in working memory. Results showed that maintaining visuospatial content in working memory hinders visual awareness, irrespective of the amount of information maintained. By contrast, the detection threshold was progressively affected under increasing executive load. Interestingly, increasing executive load had a generic effect on detection speed, calling into question whether its obstructing effect is specific to the visual awareness threshold. Together, these results indicate that visual consciousness depends differently on executive and visuospatial working memory.

  5. The visual detection of driving while intoxicated : field test of visual cues and detection methods

    DOT National Transportation Integrated Search

    1980-04-01

    A Drunk Driver Detection Guide was developed and tested at a sample of 10 law enforcement agencies at locations throughout the United States. The test was designed to provide both longitudinal and cross-sectional analyses of several measures likely t...

  6. Detection of HbsAg and hATIII genetically modified goats (Caprahircus) by loop-mediated isothermal amplification.

    PubMed

    Tao, Chenyu; Zhang, Qingde; Zhai, Shanli; Liu, Bang

    2013-11-01

    In this study, sensitive and rapid detection systems were designed using a loop-mediated isothermal amplification (LAMP) method to detect the genetically modified goats. A set of 4 primers were designed for each exogenous nucleic acids HBsAg and hATIII. The DNA samples were first amplified with the outer and inner primers and released a single-stranded DNA,of which both ends were stem-loop structure. Then one inner primer hybridized with the loop, and initiated displacement synthesis in less than 1 h. The result could be visualized by both agarose gel electrophoresis and unaided eyes directly after adding SYBR GREEN 1. The detection limit of LAMP was ten copies of target molecules, indicating that LAMP was tenfold more sensitive than the classical PCR. Furthermore, all the samples of genetically modified goats were tested positively by LAMP, and the results demonstrated that the LAMP was a rapid and sensitive method for detecting the genetically modified organism.

  7. Selective and sensitive optical chemosensor for detection of Ag(I) ions based on 2(4-hydroxy pent-3-en-2-ylideneamine) phenol in aqueous samples

    NASA Astrophysics Data System (ADS)

    Mirzaei, Mohammad; Saeed, Jaber

    2011-11-01

    A selective and sensitive chemosensor, based on the 2(4-hydroxy pent-3-en-2-ylideneamine) phenol (HPYAP) as chromophore, has been developed for colorimetric and visual detection of Ag(I) ions. HPYAP shows a considerable chromogenic behavior toward Ag(I) ions by changing the color of the solution from pale-yellow to very chromatic-yellow, which can be easily detected with the naked-eye. The chemosensor exhibited selective absorbance enhancement to Ag(I) ions in water samples over other metal ions at 438 nm, with a linear range of 0.4-500 μM ( r2 = 0.999) and a limit of detection 0.07 μM of Ag(I) ions with UV-vis spectrophotometer detection. The relative standard deviation (RSD) for 100 μM Ag(I) ions was 2.05% ( n = 7). The proposed method was applied for the determination Ag(I) ions in water and waste water samples.

  8. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    PubMed Central

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-01-01

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed. PMID:25938198

  9. Lateral interactions and speed of information processing in highly functioning multiple sclerosis patients.

    PubMed

    Nagy, Helga; Bencsik, Krisztina; Rajda, Cecília; Benedek, Krisztina; Janáky, Márta; Beniczky, Sándor; Kéri, Szabolcs; Vécsei, László

    2007-06-01

    Visual impairment is a common feature of multiple sclerosis. The aim of this study was to investigate lateral interactions in the visual cortex of highly functioning patients with multiple sclerosis and to compare that with basic visual and neuropsychologic functions. Twenty-two young, visually unimpaired multiple sclerosis patients with minimal symptoms (Expanded Disability Status Scale <2) and 30 healthy controls subjects participated in the study. Lateral interactions were investigated with the flanker task, during which participants were asked to detect the orientation of a low-contrast Gabor patch (vertical or horizontal), flanked with 2 collinear or orthogonal Gabor patches. Stimulus exposure time was 40, 60, 80, and 100 ms. Digit span forward/backward, digit symbol, verbal fluency, and California Verbal Learning Test procedures were used for background neuropsychologic assessment. Results revealed that patients with multiple sclerosis showed intact visual contrast sensitivity and neuropsychologic functions, whereas orientation detection in the orthogonal condition was significantly impaired. At 40-ms exposure time, collinear flankers facilitated the orientation detection performance of the patients resulting in normal performance. In conclusion, the detection of briefly presented, low-contrast visual stimuli was selectively impaired in multiple sclerosis. Lateral interactions between target and flankers robustly facilitated target detection in the patient group.

  10. Depth-resolved mid-infrared photothermal imaging of living cells and organisms with submicrometer spatial resolution

    PubMed Central

    Zhang, Delong; Li, Chen; Zhang, Chi; Slipchenko, Mikhail N.; Eakins, Gregory; Cheng, Ji-Xin

    2016-01-01

    Chemical contrast has long been sought for label-free visualization of biomolecules and materials in complex living systems. Although infrared spectroscopic imaging has come a long way in this direction, it is thus far only applicable to dried tissues because of the strong infrared absorption by water. It also suffers from low spatial resolution due to long wavelengths and lacks optical sectioning capabilities. We overcome these limitations through sensing vibrational absorption–induced photothermal effect by a visible laser beam. Our mid-infrared photothermal (MIP) approach reached 10 μM detection sensitivity and submicrometer lateral spatial resolution. This performance has exceeded the diffraction limit of infrared microscopy and allowed label-free three-dimensional chemical imaging of live cells and organisms. Distributions of endogenous lipid and exogenous drug inside single cells were visualized. We further demonstrated in vivo MIP imaging of lipids and proteins in Caenorhabditis elegans. The reported MIP imaging technology promises broad applications from monitoring metabolic activities to high-resolution mapping of drug molecules in living systems, which are beyond the reach of current infrared microscopy. PMID:27704043

  11. Depth-resolved mid-infrared photothermal imaging of living cells and organisms with submicrometer spatial resolution.

    PubMed

    Zhang, Delong; Li, Chen; Zhang, Chi; Slipchenko, Mikhail N; Eakins, Gregory; Cheng, Ji-Xin

    2016-09-01

    Chemical contrast has long been sought for label-free visualization of biomolecules and materials in complex living systems. Although infrared spectroscopic imaging has come a long way in this direction, it is thus far only applicable to dried tissues because of the strong infrared absorption by water. It also suffers from low spatial resolution due to long wavelengths and lacks optical sectioning capabilities. We overcome these limitations through sensing vibrational absorption-induced photothermal effect by a visible laser beam. Our mid-infrared photothermal (MIP) approach reached 10 μM detection sensitivity and submicrometer lateral spatial resolution. This performance has exceeded the diffraction limit of infrared microscopy and allowed label-free three-dimensional chemical imaging of live cells and organisms. Distributions of endogenous lipid and exogenous drug inside single cells were visualized. We further demonstrated in vivo MIP imaging of lipids and proteins in Caenorhabditis elegans . The reported MIP imaging technology promises broad applications from monitoring metabolic activities to high-resolution mapping of drug molecules in living systems, which are beyond the reach of current infrared microscopy.

  12. Novel data visualizations of X-ray data for aviation security applications using the Open Threat Assessment Platform (OTAP)

    NASA Astrophysics Data System (ADS)

    Gittinger, Jaxon M.; Jimenez, Edward S.; Holswade, Erica A.; Nunna, Rahul S.

    2017-02-01

    This work will demonstrate the implementation of a traditional and non-traditional visualization of x-ray images for aviation security applications that will be feasible with open system architecture initiatives such as the Open Threat Assessment Platform (OTAP). Anomalies of interest to aviation security are fluid, where characteristic signals of anomalies of interest can evolve rapidly. OTAP is a limited scope open architecture baggage screening prototype that intends to allow 3rd-party vendors to develop and easily implement, integrate, and deploy detection algorithms and specialized hardware on a field deployable screening technology [13]. In this study, stereoscopic images were created using an unmodified, field-deployed system and rendered on the Oculus Rift, a commercial virtual reality video gaming headset. The example described in this work is not dependent on the Oculus Rift, and is possible using any comparable hardware configuration capable of rendering stereoscopic images. The depth information provided from viewing the images will aid in the detection of characteristic signals from anomalies of interest. If successful, OTAP has the potential to allow for aviation security to become more fluid in its adaptation to the evolution of anomalies of interest. This work demonstrates one example that is easily implemented using the OTAP platform, that could lead to the future generation of ATR algorithms and data visualization approaches.

  13. Vision restoration through extrastriate stimulation in patients with visual field defects: a double-blind and randomized experimental study.

    PubMed

    Jobke, Sandra; Kasten, Erich; Sabel, Bernhard A

    2009-01-01

    . Vision restoration therapy (VRT) to treat visual field defects used single-point visual stimulation in areas of residual vision up to now. The question arises if the efficiency of restoration can be increased when the entire region of blindness is trained by a visual stimulus aimed at activating extrastriate pathways (extrastriate VRT). . In this crossover study, 18 patients with visual field defects with prior VRT experience were treated with 2 training paradigms. Group 1 (n = 8) first used extrastriate VRT followed by conventional standard VRT. Group 2 (n = 10) trained in reverse order. Visual field size was assessed with computer-based perimetry and subjective vision with the National Eye Institute Visual Function Questionnaire (NEI-VFQ). . In group 1, stimulus detection in high-resolution perimetry (HRP) improved by 5.9% (P < .01) after extrastriate VRT. After the second training period (standard VRT), detection further improved by 1.8% (P = .093). In group 2, detection performance improved after standard VRT by 2.9% (P < .05) and after extrastriate VRT by 2.9% (P < .05). Detection performance increased twice as much after extrastriate VRT (4.2%) than after standard VRT (2.4%; P < .05). All changes in fixation performance were unrelated to detection improvements. NEI-VFQ did not show any significant changes. . Greater improvement after extrastriate VRT is interpreted as an activation of extrastriate pathways by massive "spiral-like" stimulation. These pathways bypass the damaged visual cortex, stimulating extrastriate cortical regions, and are thought to be involved in blindsight.

  14. Search for and limits on plume activity on Mimas, Tethys, and Dione with the Cassini Visual Infrared Mapping Spectrometer (VIMS)

    USGS Publications Warehouse

    Buratti, B.J.; Faulk, S.P.; Mosher, J.; Baines, K.H.; Brown, R.H.; Clark, R.N.; Nicholson, P.D.

    2011-01-01

    Cassini Visual Infrared Mapping Spectrometer (VIMS) observations of Mimas, Tethys, and Dione obtained during the nominal and extended missions at large solar phase angles were analyzed to search for plume activity. No forward scattered peaks in the solar phase curves of these satellites were detected. The upper limit on water vapor production for Mimas and Tethys is one order of magnitude less than the production for Enceladus. For Dione, the upper limit is two orders of magnitude less, suggesting this world is as inert as Rhea (Pitman, K.M., Buratti, B.J., Mosher, J.A., Bauer, J.M., Momary, T., Brown, R.H., Nicholson, P.D., Hedman, M.M. [2008]. Astrophys. J. Lett. 680, L65-L68). Although the plumes are best seen at ???2.0. ??m, Imaging Science Subsystem (ISS) Narrow Angle Camera images obtained at the same time as the VIMS data were also inspected for these features. None of the Cassini ISS images shows evidence for plumes. The absence of evidence for any Enceladus-like plumes on the medium-sized saturnian satellites cannot absolutely rule out current geologic activity. The activity may below our threshold of detection, or it may be occurring but not captured on the handful of observations at large solar phase angles obtained for each moon. Many VIMS and ISS images of Enceladus at large solar phase angles, for example, do not contain plumes, as the active "tiger stripes" in the south pole region are pointed away from the spacecraft at these times. The 7-year Cassini Solstice Mission is scheduled to gather additional measurements at large solar phase angles that are capable of revealing activity on the saturnian moons. ?? 2011 Elsevier Inc.

  15. The Puzzle of Visual Development: Behavior and Neural Limits.

    PubMed

    Kiorpes, Lynne

    2016-11-09

    The development of visual function takes place over many months or years in primate infants. Visual sensitivity is very poor near birth and improves over different times courses for different visual functions. The neural mechanisms that underlie these processes are not well understood despite many decades of research. The puzzle arises because research into the factors that limit visual function in infants has found surprisingly mature neural organization and adult-like receptive field properties in very young infants. The high degree of visual plasticity that has been documented during the sensitive period in young children and animals leaves the brain vulnerable to abnormal visual experience. Abnormal visual experience during the sensitive period can lead to amblyopia, a developmental disorder of vision affecting ∼3% of children. This review provides a historical perspective on research into visual development and the disorder amblyopia. The mismatch between the status of the primary visual cortex and visual behavior, both during visual development and in amblyopia, is discussed, and several potential resolutions are considered. It seems likely that extrastriate visual areas further along the visual pathways may set important limits on visual function and show greater vulnerability to abnormal visual experience. Analyses based on multiunit, population activity may provide useful representations of the information being fed forward from primary visual cortex to extrastriate processing areas and to the motor output. Copyright © 2016 the authors 0270-6474/16/3611384-10$15.00/0.

  16. Assisting the visually impaired: obstacle detection and warning system by acoustic feedback.

    PubMed

    Rodríguez, Alberto; Yebes, J Javier; Alcantarilla, Pablo F; Bergasa, Luis M; Almazán, Javier; Cela, Andrés

    2012-12-17

    The aim of this article is focused on the design of an obstacle detection system for assisting visually impaired people. A dense disparity map is computed from the images of a stereo camera carried by the user. By using the dense disparity map, potential obstacles can be detected in 3D in indoor and outdoor scenarios. A ground plane estimation algorithm based on RANSAC plus filtering techniques allows the robust detection of the ground in every frame. A polar grid representation is proposed to account for the potential obstacles in the scene. The design is completed with acoustic feedback to assist visually impaired users while approaching obstacles. Beep sounds with different frequencies and repetitions inform the user about the presence of obstacles. Audio bone conducting technology is employed to play these sounds without interrupting the visually impaired user from hearing other important sounds from its local environment. A user study participated by four visually impaired volunteers supports the proposed system.

  17. Assisting the Visually Impaired: Obstacle Detection and Warning System by Acoustic Feedback

    PubMed Central

    Rodríguez, Alberto; Yebes, J. Javier; Alcantarilla, Pablo F.; Bergasa, Luis M.; Almazán, Javier; Cela, Andrés

    2012-01-01

    The aim of this article is focused on the design of an obstacle detection system for assisting visually impaired people. A dense disparity map is computed from the images of a stereo camera carried by the user. By using the dense disparity map, potential obstacles can be detected in 3D in indoor and outdoor scenarios. A ground plane estimation algorithm based on RANSAC plus filtering techniques allows the robust detection of the ground in every frame. A polar grid representation is proposed to account for the potential obstacles in the scene. The design is completed with acoustic feedback to assist visually impaired users while approaching obstacles. Beep sounds with different frequencies and repetitions inform the user about the presence of obstacles. Audio bone conducting technology is employed to play these sounds without interrupting the visually impaired user from hearing other important sounds from its local environment. A user study participated by four visually impaired volunteers supports the proposed system. PMID:23247413

  18. The Right Hemisphere Advantage in Visual Change Detection Depends on Temporal Factors

    ERIC Educational Resources Information Center

    Spotorno, Sara; Faure, Sylvane

    2011-01-01

    What accounts for the Right Hemisphere (RH) functional superiority in visual change detection? An original task which combines one-shot and divided visual field paradigms allowed us to direct change information initially to the RH or the Left Hemisphere (LH) by deleting, respectively, an object included in the left or right half of a scene…

  19. Posture-based processing in visual short-term memory for actions.

    PubMed

    Vicary, Staci A; Stevens, Catherine J

    2014-01-01

    Visual perception of human action involves both form and motion processing, which may rely on partially dissociable neural networks. If form and motion are dissociable during visual perception, then they may also be dissociable during their retention in visual short-term memory (VSTM). To elicit form-plus-motion and form-only processing of dance-like actions, individual action frames can be presented in the correct or incorrect order. The former appears coherent and should elicit action perception, engaging both form and motion pathways, whereas the latter appears incoherent and should elicit posture perception, engaging form pathways alone. It was hypothesized that, if form and motion are dissociable in VSTM, then recognition of static body posture should be better after viewing incoherent than after viewing coherent actions. However, as VSTM is capacity limited, posture-based encoding of actions may be ineffective with increased number of items or frames. Using a behavioural change detection task, recognition of a single test posture was significantly more likely after studying incoherent than after studying coherent stimuli. However, this effect only occurred for spans of two (but not three) items and for stimuli with five (but not nine) frames. As in perception, posture and motion are dissociable in VSTM.

  20. The Gestalt Principle of Similarity Benefits Visual Working Memory

    PubMed Central

    Peterson, Dwight J.; Berryhill, Marian E.

    2013-01-01

    Visual working memory (VWM) is essential for many cognitive processes yet it is notably limited in capacity. Visual perception processing is facilitated by Gestalt principles of grouping, such as connectedness, similarity, and proximity. This introduces the question: do these perceptual benefits extend to VWM? If so, can this be an approach to enhance VWM function by optimizing the processing of information? Previous findings demonstrate that several Gestalt principles (connectedness, common region, and spatial proximity) do facilitate VWM performance in change detection tasks (Woodman, Vecera, & Luck, 2003; Xu, 2002a, 2006; Xu & Chun, 2007; Jiang, Olson & Chun, 2000). One prevalent Gestalt principle, similarity, has not been examined with regard to facilitating VWM. Here, we investigated whether grouping by similarity benefits VWM. Experiment 1 established the basic finding that VWM performance could benefit from grouping. Experiment 2 replicated and extended this finding by showing that similarity was only effective when the similar stimuli were proximal. In short, the VWM performance benefit derived from similarity was constrained by spatial proximity such that similar items need to be near each other. Thus, the Gestalt principle of similarity benefits visual perception, but it can provide benefits to VWM as well. PMID:23702981

  1. The Gestalt principle of similarity benefits visual working memory.

    PubMed

    Peterson, Dwight J; Berryhill, Marian E

    2013-12-01

    Visual working memory (VWM) is essential for many cognitive processes, yet it is notably limited in capacity. Visual perception processing is facilitated by Gestalt principles of grouping, such as connectedness, similarity, and proximity. This introduces the question, do these perceptual benefits extend to VWM? If so, can this be an approach to enhance VWM function by optimizing the processing of information? Previous findings have demonstrated that several Gestalt principles (connectedness, common region, and spatial proximity) do facilitate VWM performance in change detection tasks (Jiang, Olson, & Chun, 2000; Woodman, Vecera, & Luck, 2003; Xu, 2002, 2006; Xu & Chun, 2007). However, one prevalent Gestalt principle, similarity, has not been examined with regard to facilitating VWM. Here, we investigated whether grouping by similarity benefits VWM. Experiment 1 established the basic finding that VWM performance could benefit from grouping. Experiment 2 replicated and extended this finding by showing that similarity was only effective when the similar stimuli were proximal. In short, the VWM performance benefit derived from similarity was constrained by spatial proximity, such that similar items need to be near each other. Thus, the Gestalt principle of similarity benefits visual perception, but it can provide benefits to VWM as well.

  2. Effects of feature-selective and spatial attention at different stages of visual processing.

    PubMed

    Andersen, Søren K; Fuchs, Sandra; Müller, Matthias M

    2011-01-01

    We investigated mechanisms of concurrent attentional selection of location and color using electrophysiological measures in human subjects. Two completely overlapping random dot kinematograms (RDKs) of two different colors were presented on either side of a central fixation cross. On each trial, participants attended one of these four RDKs, defined by its specific combination of color and location, in order to detect coherent motion targets. Sustained attentional selection while monitoring for targets was measured by means of steady-state visual evoked potentials (SSVEPs) elicited by the frequency-tagged RDKs. Attentional selection of transient targets and distractors was assessed by behavioral responses and by recording event-related potentials to these stimuli. Spatial attention and attention to color had independent and largely additive effects on the amplitudes of SSVEPs elicited in early visual areas. In contrast, behavioral false alarms and feature-selective modulation of P3 amplitudes to targets and distractors were limited to the attended location. These results suggest that feature-selective attention produces an early, global facilitation of stimuli having the attended feature throughout the visual field, whereas the discrimination of target events takes place at a later stage of processing that is only applied to stimuli at the attended position.

  3. The signature of undetected change: an exploratory electrotomographic investigation of gradual change blindness.

    PubMed

    Kiat, John E; Dodd, Michael D; Belli, Robert F; Cheadle, Jacob E

    2018-05-01

    Neuroimaging-based investigations of change blindness, a phenomenon in which seemingly obvious changes in visual scenes fail to be detected, have significantly advanced our understanding of visual awareness. The vast majority of prior investigations, however, utilize paradigms involving visual disruptions (e.g., intervening blank screens, saccadic movements, "mudsplashes"), making it difficult to isolate neural responses toward visual changes cleanly. To address this issue in this present study, high-density EEG data (256 channel) were collected from 25 participants using a paradigm in which visual changes were progressively introduced into detailed real-world scenes without the use of visual disruption. Oscillatory activity associated with undetected changes was contrasted with activity linked to their absence using standardized low-resolution brain electromagnetic tomography (sLORETA). Although an insufficient number of detections were present to allow for analysis of actual change detection, increased beta-2 activity in the right inferior parietal lobule (rIPL), a region repeatedly associated with change blindness in disruption paradigms, followed by increased theta activity in the right superior temporal gyrus (rSTG) was noted in undetected visual change responses relative to the absence of change. We propose the rIPL beta-2 activity to be associated with orienting attention toward visual changes, with the subsequent rise in rSTG theta activity being potentially linked with updating preconscious perceptual memory representations. NEW & NOTEWORTHY This study represents the first neuroimaging-based investigation of gradual change blindness, a visual phenomenon that has significant potential to shed light on the processes underlying visual detection and conscious perception. The use of gradual change materials is reflective of real-world visual phenomena and allows for cleaner isolation of signals associated with the neural registration of change relative to the use of abrupt change transients.

  4. Electropysiologic evaluation of the visual pathway in patients with multiple sclerosis.

    PubMed

    Rodriguez-Mena, Diego; Almarcegui, Carmen; Dolz, Isabel; Herrero, Raquel; Bambo, Maria P; Fernandez, Javier; Pablo, Luis E; Garcia-Martin, Elena

    2013-08-01

    To evaluate the ability of visual evoked potentials and pattern electroretinograms (PERG) to detect subclinical axonal damage in patients during the early diagnostic stage of multiple sclerosis (MS). The authors also compared the ability of optical coherence tomography (OCT), PERG, and visual evoked potentials to detect axonal loss in MS patients and correlated the functional and structural properties of the retinal nerve fiber layer. Two hundred twenty-eight eyes of 114 subjects (57 MS patients and 57 age- and sex-matched healthy controls) were included. The visual pathway was evaluated based on functional and structural assessments. All patients underwent a complete ophthalmic examination that included assessment of visual acuity, ocular motility, intraocular pressure, visual field, papillary morphology, OCT, visual evoked potentials, and PERG. Visual evoked potentials (P100 latency and amplitude), PERG (N95 amplitude and N95/P50 ratio), and OCT parameters differed significantly between MS patients and healthy subjects. Moderate significant correlations were found between visual evoked potentials or PERG parameters and OCT measurements. Axonal damage in ganglion cells of the visual pathway can be detected based on structural measures provided by OCT in MS patients and by the N95 component and N95/P50 index of PERG, thus providing good correlation between function and structure.

  5. Repeatability of normal multifocal VEP: implications for detecting progression.

    PubMed

    Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Johnson, Chris A

    2006-04-01

    To assess the repeatability of the multifocal visual evoked potential (mfVEP) and to compare it with the repeatability of standard automated perimetry (SAP) in the same group of 50 normal controls retested after 1 year. Our second aim was to assess the repeatability of false alarm rates determined previously for the mfVEP using various cluster criteria. Fifty individuals with normal vision participated in this study (33 females and 17 males). The age range was 26.7 to 77.9 years and the group average age (+/- SD) was 51.4 (+/- 12.1) years. Pattern-reversal mfVEPs were obtained using a dartboard stimulus pattern in VERIS and two 8-minute runs per eye were averaged. The average number of days between the first and second mfVEP tests was 378 (+/- 58). SAP visual fields were obtained within 17.4 (+/- 20.3) days of the mfVEP using the SITA-standard threshold algorithm. Repeatability of mfVEPs and SAP total deviation values were evaluated by calculating point-wise limits of agreement (LOA). Specificity (1-false alarm rate) was evaluated for a range of cluster criteria, whereby the number and probability level of the points defining a cluster were varied. Point-wise LOA for the mfVEP signal-to-noise ratio (SNR) ranged from 2.0 to 4.3 dB, with an average of 2.9 dB across all 60 locations. For SAP, LOA ranged from 2.4 to 8.9 dB, with an average of 4.0 dB (excluding the points immediately above and below the blind spot). Clusters of abnormal points were not likely to repeat on either mfVEP or SAP. When an mfVEP abnormality was defined as the repeat presence (confirmation) of a 3-point (P < 0.05) cluster anywhere within a single hemifield, only 1 (of 200) monocular hemifield was deemed abnormal. Although the LOA of the mfVEP were similar throughout the field, the limited dynamic range of SNR at superior field locations will limit the ability to follow progression in "depth" at those locations. Repeatability of the mfVEP was slightly better than SAP visual fields in this group of controls with a 1-year retest interval. This suggests that progression in early stages should be more easily detectable by mfVEP. However, in certain field locations (eg, superior periphery), the relatively more narrow dynamic range of the SNR of the mfVEP may limit detection of progression to just 1 event. Confirmation of a 3-point cluster abnormality is highly suggestive of a true defect on the mfVEP.

  6. Making the Invisible Visible: Verbal but Not Visual Cues Enhance Visual Detection

    PubMed Central

    Lupyan, Gary; Spivey, Michael J.

    2010-01-01

    Background Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. Methodology/Principal Findings Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d′). A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. Conclusions/Significance Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception. PMID:20628646

  7. Default perception of high-speed motion

    PubMed Central

    Wexler, Mark; Glennerster, Andrew; Cavanagh, Patrick; Ito, Hiroyuki; Seno, Takeharu

    2013-01-01

    When human observers are exposed to even slight motion signals followed by brief visual transients—stimuli containing no detectable coherent motion signals—they perceive large and salient illusory jumps. This visually striking effect, which we call “high phi,” challenges well-entrenched assumptions about the perception of motion, namely the minimal-motion principle and the breakdown of coherent motion perception with steps above an upper limit called dmax. Our experiments with transients, such as texture randomization or contrast reversal, show that the magnitude of the jump depends on spatial frequency and transient duration—but not on the speed of the inducing motion signals—and the direction of the jump depends on the duration of the inducer. Jump magnitude is robust across jump directions and different types of transient. In addition, when a texture is actually displaced by a large step beyond the upper step size limit of dmax, a breakdown of coherent motion perception is expected; however, in the presence of an inducer, observers again perceive coherent displacements at or just above dmax. In summary, across a large variety of stimuli, we find that when incoherent motion noise is preceded by a small bias, instead of perceiving little or no motion—as suggested by the minimal-motion principle—observers perceive jumps whose amplitude closely follows their own dmax limits. PMID:23572578

  8. Capacity and precision in an animal model of visual short-term memory

    PubMed Central

    Lara, Antonio H.; Wallis, Jonathan D.

    2013-01-01

    Temporary storage of information in visual short-term memory (VSTM) is a key component of many complex cognitive abilities. However, it is highly limited in capacity. Understanding the neurophysiological nature of this capacity limit will require a valid animal model of VSTM. We used a multiple-item color change detection task to measure macaque monkeys’ VSTM capacity. Subjects’ performance deteriorated and reaction times increased as a function of the number of items in memory. Additionally, we measured the precision of the memory representations by varying the distance between sample and test colors. In trials with similar sample and test colors, subjects made more errors compared to trials with highly discriminable colors. We modeled the error distribution as a Gaussian function and used this to estimate the precision of VSTM representations. We found that as the number of items in memory increases the precision of the representations decreases dramatically. Additionally, we found that focusing attention on one of the objects increases the precision with which that object is stored and degrading the precision of the remaining. These results are in line with recent findings in human psychophysics and provide a solid foundation for understanding the neurophysiological nature of the capacity limit of VSTM. PMID:22419756

  9. Math Majors' Visual Proofs in a Dynamic Environment: The Case of Limit of a Function and the ?-d Approach

    ERIC Educational Resources Information Center

    Caglayan, Günhan

    2015-01-01

    Despite few limitations, GeoGebra as a dynamic geometry software stood as a powerful instrument in helping university math majors understand, explore, and gain experiences in visualizing the limits of functions and the ?-d formalism. During the process of visualizing a theorem, the order mattered in the sequence of constituents. Students made use…

  10. Objective automated quantification of fluorescence signal in histological sections of rat lens.

    PubMed

    Talebizadeh, Nooshin; Hagström, Nanna Zhou; Yu, Zhaohua; Kronschläger, Martin; Söderberg, Per; Wählby, Carolina

    2017-08-01

    Visual quantification and classification of fluorescent signals is the gold standard in microscopy. The purpose of this study was to develop an automated method to delineate cells and to quantify expression of fluorescent signal of biomarkers in each nucleus and cytoplasm of lens epithelial cells in a histological section. A region of interest representing the lens epithelium was manually demarcated in each input image. Thereafter, individual cell nuclei within the region of interest were automatically delineated based on watershed segmentation and thresholding with an algorithm developed in Matlab™. Fluorescence signal was quantified within nuclei, cytoplasms and juxtaposed backgrounds. The classification of cells as labelled or not labelled was based on comparison of the fluorescence signal within cells with local background. The classification rule was thereafter optimized as compared with visual classification of a limited dataset. The performance of the automated classification was evaluated by asking 11 independent blinded observers to classify all cells (n = 395) in one lens image. Time consumed by the automatic algorithm and visual classification of cells was recorded. On an average, 77% of the cells were correctly classified as compared with the majority vote of the visual observers. The average agreement among visual observers was 83%. However, variation among visual observers was high, and agreement between two visual observers was as low as 71% in the worst case. Automated classification was on average 10 times faster than visual scoring. The presented method enables objective and fast detection of lens epithelial cells and quantification of expression of fluorescent signal with an accuracy comparable with the variability among visual observers. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  11. The role of extra-foveal processing in 3D imaging

    NASA Astrophysics Data System (ADS)

    Eckstein, Miguel P.; Lago, Miguel A.; Abbey, Craig K.

    2017-03-01

    The field of medical image quality has relied on the assumption that metrics of image quality for simple visual detection tasks are a reliable proxy for the more clinically realistic visual search tasks. Rank order of signal detectability across conditions often generalizes from detection to search tasks. Here, we argue that search in 3D images represents a paradigm shift in medical imaging: radiologists typically cannot exhaustively scrutinize all regions of interest with the high acuity fovea requiring detection of signals with extra-foveal areas (visual periphery) of the human retina. We hypothesize that extra-foveal processing can alter the detectability of certain types of signals in medical images with important implications for search in 3D medical images. We compare visual search of two different types of signals in 2D vs. 3D images. We show that a small microcalcification-like signal is more highly detectable than a larger mass-like signal in 2D search, but its detectability largely decreases (relative to the larger signal) in the 3D search task. Utilizing measurements of observer detectability as a function retinal eccentricity and observer eye fixations we can predict the pattern of results in the 2D and 3D search studies. Our findings: 1) suggest that observer performance findings with 2D search might not always generalize to 3D search; 2) motivate the development of a new family of model observers that take into account the inhomogeneous visual processing across the retina (foveated model observers).

  12. Mental workload while driving: effects on visual search, discrimination, and decision making.

    PubMed

    Recarte, Miguel A; Nunes, Luis M

    2003-06-01

    The effects of mental workload on visual search and decision making were studied in real traffic conditions with 12 participants who drove an instrumented car. Mental workload was manipulated by having participants perform several mental tasks while driving. A simultaneous visual-detection and discrimination test was used as performance criteria. Mental tasks produced spatial gaze concentration and visual-detection impairment, although no tunnel vision occurred. According to ocular behavior analysis, this impairment was due to late detection and poor identification more than to response selection. Verbal acquisition tasks were innocuous compared with production tasks, and complex conversations, whether by phone or with a passenger, are dangerous for road safety.

  13. Math majors' visual proofs in a dynamic environment: the case of limit of a function and the ɛ-δ approach

    NASA Astrophysics Data System (ADS)

    Caglayan, Günhan

    2015-08-01

    Despite few limitations, GeoGebra as a dynamic geometry software stood as a powerful instrument in helping university math majors understand, explore, and gain experiences in visualizing the limits of functions and the ɛ - δ formalism. During the process of visualizing a theorem, the order mattered in the sequence of constituents. Students made use of such rich constituents as finger-hand gestures and cursor gestures in an attempt to keep a record of visual demonstration in progress, while being aware of the interrelationships among these constituents and the transformational aspect of the visually proving process. Covariational reasoning along with interval mapping structures proved to be the key constituents in the visualizing and sense-making of a limit theorem using the delta-epsilon formalism. Pedagogical approaches and teaching strategies based on experimental mathematics - mindtool - consituential visual proofs trio would permit students to study, construct, and meaningfully connect the new knowledge to the previously mastered concepts and skills in a manner that would make sense for them.

  14. A magnetic/fluorometric bimodal sensor based on a carbon dots-MnO2 platform for glutathione detection

    NASA Astrophysics Data System (ADS)

    Xu, Yang; Chen, Xi; Chai, Ran; Xing, Chengfen; Li, Huanrong; Yin, Xue-Bo

    2016-07-01

    A novel magnetic/fluorometric bimodal sensor was built from carbon dots (CDs) and MnO2. The resulting sensor was sensitive to glutathione (GSH), leading to apparent enhancement of magnetic resonance (MR) and fluorescence signals along with visual changes. The bimodal detection strategy is based on the decomposition of the CDs-MnO2 through a redox reaction between GSH and MnO2. This process causes the transformation from non-MR-active MnO2 to MR-active Mn2+, and is accompanied by fluorescence restoration of CDs. Compared with a range of other CDs, the polyethylenimine (PEI) passivated CDs (denoted as pCDs) were suitable for detection due to their positive surface potential. Cross-validation between MR and fluorescence provided detailed information regarding the MnO2 reduction process, and revealed the three distinct stages of the redox process. Thus, the design of a CD-based sensor for the magnetic/fluorometric bimodal detection of GSH was emphasized for the first time. This platform showed a detection limit of 0.6 μM with a linear range of 1-200 μM in the fluorescence mode, while the MR mode exhibited a linear range of 5-200 μM and a GSH detection limit of 2.8 μM with a visible change being observed rapidly at 1 μM in the MR images. Furthermore, the introduction of the MR mode allowed the biothiols to be easily identified. The integration of CD fluorescence with an MR response was demonstrated to be promising for providing detailed information and discriminating power, and therefore extend the application of CDs in sensing and imaging.A novel magnetic/fluorometric bimodal sensor was built from carbon dots (CDs) and MnO2. The resulting sensor was sensitive to glutathione (GSH), leading to apparent enhancement of magnetic resonance (MR) and fluorescence signals along with visual changes. The bimodal detection strategy is based on the decomposition of the CDs-MnO2 through a redox reaction between GSH and MnO2. This process causes the transformation from non-MR-active MnO2 to MR-active Mn2+, and is accompanied by fluorescence restoration of CDs. Compared with a range of other CDs, the polyethylenimine (PEI) passivated CDs (denoted as pCDs) were suitable for detection due to their positive surface potential. Cross-validation between MR and fluorescence provided detailed information regarding the MnO2 reduction process, and revealed the three distinct stages of the redox process. Thus, the design of a CD-based sensor for the magnetic/fluorometric bimodal detection of GSH was emphasized for the first time. This platform showed a detection limit of 0.6 μM with a linear range of 1-200 μM in the fluorescence mode, while the MR mode exhibited a linear range of 5-200 μM and a GSH detection limit of 2.8 μM with a visible change being observed rapidly at 1 μM in the MR images. Furthermore, the introduction of the MR mode allowed the biothiols to be easily identified. The integration of CD fluorescence with an MR response was demonstrated to be promising for providing detailed information and discriminating power, and therefore extend the application of CDs in sensing and imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03129c

  15. Variability Properties of Four Million Sources in the TESS Input Catalog Observed with the Kilodegree Extremely Little Telescope Survey

    NASA Astrophysics Data System (ADS)

    Oelkers, Ryan J.; Rodriguez, Joseph E.; Stassun, Keivan G.; Pepper, Joshua; Somers, Garrett; Kafka, Stella; Stevens, Daniel J.; Beatty, Thomas G.; Siverd, Robert J.; Lund, Michael B.; Kuhn, Rudolf B.; James, David; Gaudi, B. Scott

    2018-01-01

    The Kilodegree Extremely Little Telescope (KELT) has been surveying more than 70% of the celestial sphere for nearly a decade. While the primary science goal of the survey is the discovery of transiting, large-radii planets around bright host stars, the survey has collected more than 106 images, with a typical cadence between 10–30 minutes, for more than four million sources with apparent visual magnitudes in the approximate range 7< V< 13. Here, we provide a catalog of 52,741 objects showing significant large-amplitude fluctuations likely caused by stellar variability, as well as 62,229 objects identified with likely stellar rotation periods. The detected variability ranges in rms-amplitude from ∼3 mmag to ∼2.3 mag, and the detected periods range from ∼0.1 to ≳2000 days. We provide variability upper limits for all other ∼4,000,000 sources. These upper limits are principally a function of stellar brightness, but we achieve typical 1σ sensitivity on 30 min timescales down to ∼5 mmag at V∼ 8, and down to ∼43 mmag at V∼ 13. We have matched our catalog to the TESS Input catalog and the AAVSO Variable Star Index to precipitate the follow-up and classification of each source. The catalog is maintained as a living database on the Filtergraph visualization portal at the URL https://filtergraph.com/kelt_vars.

  16. A fully integrated distance readout ELISA-Chip for point-of-care testing with sample-in-answer-out capability.

    PubMed

    Liu, Dan; Li, Xingrui; Zhou, Junkai; Liu, Shibo; Tian, Tian; Song, Yanling; Zhu, Zhi; Zhou, Leiji; Ji, Tianhai; Yang, Chaoyong

    2017-10-15

    Enzyme-linked immunosorbent assay (ELISA) is a popular laboratory technique for detection of disease-specific protein biomarkers with high specificity and sensitivity. However, ELISA requires labor-intensive and time-consuming procedures with skilled operators and spectroscopic instrumentation. Simplification of the procedures and miniaturization of the devices are crucial for ELISA-based point-of-care (POC) testing in resource-limited settings. Here, we present a fully integrated, instrument-free, low-cost and portable POC platform which integrates the process of ELISA and the distance readout into a single microfluidic chip. Based on manipulation using a permanent magnet, the process is initiated by moving magnetic beads with capture antibody through different aqueous phases containing ELISA reagents to form bead/antibody/antigen/antibody sandwich structure, and finally converts the molecular recognition signal into a highly sensitive distance readout for visual quantitative bioanalysis. Without additional equipment and complicated operations, our integrated ELISA-Chip with distance readout allows ultrasensitive quantitation of disease biomarkers within 2h. The ELISA-Chip method also showed high specificity, good precision and great accuracy. Furthermore, the ELISA-Chip system is highly applicable as a sandwich-based platform for the detection of a variety of protein biomarkers. With the advantages of visual analysis, easy operation, high sensitivity, and low cost, the integrated sample-in-answer-out ELISA-Chip with distance readout shows great potential for quantitative POCT in resource-limited settings. Copyright © 2017. Published by Elsevier B.V.

  17. LAMP-based group specific detection of aflatoxin producers within Aspergillus section Flavi in food raw materials, spices, and dried fruit using neutral red for visible-light signal detection.

    PubMed

    Niessen, Ludwig; Bechtner, Julia; Fodil, Sihem; Taniwaki, Marta H; Vogel, Rudi F

    2018-02-02

    Aflatoxins can be produced by 21 species within sections Flavi (16 species), Ochraceorosei (2), and Nidulantes (3) of the fungal genus Aspergillus. They pose risks to human and animal health due to high toxicity and carcinogenicity. Detecting aflatoxin producers can help to assess toxicological risks associated with contaminated commodities. Species specific molecular assays (PCR and LAMP) are available for detection of major producers, but fail to detect species of minor importance. To enable rapid and sensitive detection of several aflatoxin producing species in a single analysis, a nor1 gene-specific LAMP assay was developed. Specificity testing showed that among 128 fungal species from 28 genera, 15 aflatoxigenic species in section Flavi were detected, including synonyms of A. flavus and A. parasiticus. No cross reactions were found with other tested species. The detection limit of the assay was 9.03pg of A. parasiticus genomic DNA per reaction. Visual detection of positive LAMP reactions under daylight conditions was facilitated using neutral red to allow unambiguous distinction between positive and negative assay results. Application of the assay to the detection of A. parasiticus conidia revealed a detection limit of 211 conidia per reaction after minimal sample preparation. The usefulness of the assay was demonstrated in the analysis of aflatoxinogenic species in samples of rice, nuts, raisins, dried figs, as well as powdered spices. Comparison of LAMP results with presence/absence of aflatoxins and aflatoxin producing fungi in 50 rice samples showed good correlation between these parameters. Our study suggests that the developed LAMP assay is a rapid, sensitive and user-friendly tool for surveillance and quality control in our food industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Driver Distraction Using Visual-Based Sensors and Algorithms.

    PubMed

    Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén

    2016-10-28

    Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed.

  19. Driver Distraction Using Visual-Based Sensors and Algorithms

    PubMed Central

    Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén

    2016-01-01

    Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed. PMID:27801822

  20. An improved clenbuterol detection by immunochromatographic assay with bacteria@Au composite as signal amplifier.

    PubMed

    Huang, Qiong; Bu, Tong; Zhang, Wentao; Yan, Lingzhi; Zhang, Mengyue; Yang, Qingfeng; Huang, Lunjie; Yang, Baowei; Hu, Na; Suo, Yourui; Wang, Jianlong; Zhang, Daohong

    2018-10-01

    Immunochromatographic assays (ICAs) are most frequently used for on-site rapid screening of clenbuterol. To improve sensitivity, a novel probe with bacteria as signal carriers was developed. Bacteria can load a great deal of gold nanoparticles (AuNPs) on their surface, meaning much fewer antibodies are needed to produce clearly visible results, although low concentrations of antibody could also trigger fierce competition between free analyte and the immobilized antigen. Thus, a limited number of antibodies was key to significantly improved sensitivity. Analytical conditions, including bacterial species, coupling method, and concentration, were optimized. The visual detection limit (VDL) for clenbuterol was 0.1 ng/mL, a 20-fold improvement in sensitivity compared with traditional strips. This work has opened up a new route for signal amplification and improved performance of ICAs. Furthermore, inactivated bacteria could also be environment-friendly and robust signal carriers for other biosensors. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. States of Awareness I: Subliminal Perception Relationship to Situational Awareness

    DTIC Science & Technology

    1993-05-01

    one experiment, the visual detection threshold was raised by simultaneous auditory stimulation involving subliminal emotional words. Similar results...an assessment was made of the effects of both subliminal and supraliminal auditory accessory stimulation (white noise) on a visual detection task... stimulation investigation. Both subliminal and supraliminal auditory stimulation were employed to evaluate possible differential effects in visual illusions

  2. Comparison on driving fatigue related hemodynamics activated by auditory and visual stimulus

    NASA Astrophysics Data System (ADS)

    Deng, Zishan; Gao, Yuan; Li, Ting

    2018-02-01

    As one of the main causes of traffic accidents, driving fatigue deserves researchers' attention and its detection and monitoring during long-term driving require a new technique to realize. Since functional near-infrared spectroscopy (fNIRS) can be applied to detect cerebral hemodynamic responses, we can promisingly expect its application in fatigue level detection. Here, we performed three different kinds of experiments on a driver and recorded his cerebral hemodynamic responses when driving for long hours utilizing our device based on fNIRS. Each experiment lasted for 7 hours and one of the three specific experimental tests, detecting the driver's response to sounds, traffic lights and direction signs respectively, was done every hour. The results showed that visual stimulus was easier to cause fatigue compared with auditory stimulus and visual stimulus induced by traffic lights scenes was easier to cause fatigue compared with visual stimulus induced by direction signs in the first few hours. We also found that fatigue related hemodynamics caused by auditory stimulus increased fastest, then traffic lights scenes, and direction signs scenes slowest. Our study successfully compared audio, visual color, and visual character stimulus in sensitivity to cause driving fatigue, which is meaningful for driving safety management.

  3. Hierarchical NiCo2O4 Hollow Sphere as a Peroxidase Mimetic for Colorimetric Detection of H2O2 and Glucose

    PubMed Central

    Huang, Wei; Lin, Tianye; Cao, Yang; Lai, Xiaoyong; Peng, Juan; Tu, Jinchun

    2017-01-01

    In this work, the hierarchical NiCo2O4 hollow sphere synthesized via a “coordinating etching and precipitating” process was demonstrated to exhibit intrinsic peroxidase-like activity. The peroxidase-like activity of NiCo2O4, NiO, and Co3O4 hollow spheres were comparatively studied by the catalytic oxidation reaction of 3,3,5,5-tetramethylbenzidine (TMB) in presence of H2O2, and a superior peroxidase-like activity of NiCo2O4 was confirmed by stronger absorbance at 652 nm. Furthermore, the proposed sensing platform showed commendable response to H2O2 with a linear range from 10 μM to 400 μM, and a detection limit of 0.21 μM. Cooperated with GOx, the developed novel colorimetric and visual glucose-sensing platform exhibited high selectivity, favorable reproducibility, satisfactory applicability, wide linear range (from 0.1 mM to 4.5 mM), and a low detection limit of 5.31 μM. In addition, the concentration-dependent color change would offer a better and handier way for detection of H2O2 and glucose by naked eye. PMID:28124997

  4. 4-(2-Pyridylazo)-resorcinol Functionalized Thermosensitive Ionic Microgels for Optical Detection of Heavy Metal Ions at Nanomolar Level.

    PubMed

    Zhou, Xianjing; Nie, Jingjing; Du, Binyang

    2015-10-07

    4-(2-Pyridylazo)-resorcinol (PAR) functionalized thermosensitive ionic microgels (PAR-MG) were synthesized by a one-pot quaternization method. The PAR-MG microgels were spherical in shape with radius of ca. 166.0 nm and narrow size distribution and exhibited thermo-sensitivity in aqueous solution. The PAR-MG microgels could optically detect trace heavy metal ions, such as Cu(2+), Mn(2+), Pb(2+), Zn(2+), and Ni(2+), in aqueous solutions with high selectivity and sensitivity. The PAR-MG microgel suspensions exhibited characteristic color with the presence of various trace heavy metal ions, which could be visually distinguished by naked eyes. The limit of colorimetric detection (DL) was determined to be 38 nM for Cu(2+) at pH 3, 12 nM for Cu(2+) at pH 7, and 14, 79, 20, and 21 nM for Mn(2+), Pb(2+), Zn(2+), and Ni(2+), respectively, at pH 11, which was lower than (or close to) the United States Environmental Protection Agency standard for the safety limit of these heavy metal ions in drinking water. The mechanism of detection was attributed to the chelation between the nitrogen atoms and o-hydroxyl groups of PAR within the microgels and heavy metal ions.

  5. Dissociations of the number and precision of visual short-term memory representations in change detection.

    PubMed

    Xie, Weizhen; Zhang, Weiwei

    2017-11-01

    The present study dissociated the number (i.e., quantity) and precision (i.e., quality) of visual short-term memory (STM) representations in change detection using receiver operating characteristic (ROC) and experimental manipulations. Across three experiments, participants performed both recognition and recall tests of visual STM using the change-detection task and the continuous color-wheel recall task, respectively. Experiment 1 demonstrated that the estimates of the number and precision of visual STM representations based on the ROC model of change-detection performance were robustly correlated with the corresponding estimates based on the mixture model of continuous-recall performance. Experiments 2 and 3 showed that the experimental manipulation of mnemonic precision using white-noise masking and the experimental manipulation of the number of encoded STM representations using consolidation masking produced selective effects on the corresponding measures of mnemonic precision and the number of encoded STM representations, respectively, in both change-detection and continuous-recall tasks. Altogether, using the individual-differences (Experiment 1) and experimental dissociation (Experiment 2 and 3) approaches, the present study demonstrated the some-or-none nature of visual STM representations across recall and recognition.

  6. Common neural substrates for visual working memory and attention.

    PubMed

    Mayer, Jutta S; Bittner, Robert A; Nikolić, Danko; Bledowski, Christoph; Goebel, Rainer; Linden, David E J

    2007-06-01

    Humans are severely limited in their ability to memorize visual information over short periods of time. Selective attention has been implicated as a limiting factor. Here we used functional magnetic resonance imaging to test the hypothesis that this limitation is due to common neural resources shared by visual working memory (WM) and selective attention. We combined visual search and delayed discrimination of complex objects and independently modulated the demands on selective attention and WM encoding. Participants were presented with a search array and performed easy or difficult visual search in order to encode one or three complex objects into visual WM. Overlapping activation for attention-demanding visual search and WM encoding was observed in distributed posterior and frontal regions. In the right prefrontal cortex and bilateral insula blood oxygen-level-dependent activation additively increased with increased WM load and attentional demand. Conversely, several visual, parietal and premotor areas showed overlapping activation for the two task components and were severely reduced in their WM load response under the condition with high attentional demand. Regions in the left prefrontal cortex were selectively responsive to WM load. Areas selectively responsive to high attentional demand were found within the right prefrontal and bilateral occipital cortex. These results indicate that encoding into visual WM and visual selective attention require to a high degree access to common neural resources. We propose that competition for resources shared by visual attention and WM encoding can limit processing capabilities in distributed posterior brain regions.

  7. Picture Detection in Rapid Serial Visual Presentation: Features or Identity?

    ERIC Educational Resources Information Center

    Potter, Mary C.; Wyble, Brad; Pandav, Rijuta; Olejarczyk, Jennifer

    2010-01-01

    A pictured object can be readily detected in a rapid serial visual presentation sequence when the target is specified by a superordinate category name such as "animal" or "vehicle". Are category features the initial basis for detection, with identification of the specific object occurring in a second stage (Evans &…

  8. Hazardous sign detection for safety applications in traffic monitoring

    NASA Astrophysics Data System (ADS)

    Benesova, Wanda; Kottman, Michal; Sidla, Oliver

    2012-01-01

    The transportation of hazardous goods in public streets systems can pose severe safety threats in case of accidents. One of the solutions for these problems is an automatic detection and registration of vehicles which are marked with dangerous goods signs. We present a prototype system which can detect a trained set of signs in high resolution images under real-world conditions. This paper compares two different methods for the detection: bag of visual words (BoW) procedure and our approach presented as pairs of visual words with Hough voting. The results of an extended series of experiments are provided in this paper. The experiments show that the size of visual vocabulary is crucial and can significantly affect the recognition success rate. Different code-book sizes have been evaluated for this detection task. The best result of the first method BoW was 67% successfully recognized hazardous signs, whereas the second method proposed in this paper - pairs of visual words and Hough voting - reached 94% of correctly detected signs. The experiments are designed to verify the usability of the two proposed approaches in a real-world scenario.

  9. Application of Deep Learning in Automated Analysis of Molecular Images in Cancer: A Survey

    PubMed Central

    Xue, Yong; Chen, Shihui; Liu, Yong

    2017-01-01

    Molecular imaging enables the visualization and quantitative analysis of the alterations of biological procedures at molecular and/or cellular level, which is of great significance for early detection of cancer. In recent years, deep leaning has been widely used in medical imaging analysis, as it overcomes the limitations of visual assessment and traditional machine learning techniques by extracting hierarchical features with powerful representation capability. Research on cancer molecular images using deep learning techniques is also increasing dynamically. Hence, in this paper, we review the applications of deep learning in molecular imaging in terms of tumor lesion segmentation, tumor classification, and survival prediction. We also outline some future directions in which researchers may develop more powerful deep learning models for better performance in the applications in cancer molecular imaging. PMID:29114182

  10. [Imaging Mass Spectrometry in Histopathologic Analysis].

    PubMed

    Yamazaki, Fumiyoshi; Seto, Mitsutoshi

    2015-04-01

    Matrix-assisted laser desorption/ionization (MALDI)-imaging mass spectrometry (IMS) enables visualization of the distribution of a range of biomolecules by integrating biochemical information from mass spectrometry with positional information from microscopy. IMS identifies a target molecule. In addition, IMS enables global analysis of biomolecules containing unknown molecules by detecting the ratio of the molecular weight to electric charge without any target, which makes it possible to identify novel molecules. IMS generates data on the distribution of lipids and small molecules in tissues, which is difficult to visualize with either conventional counter-staining or immunohistochemistry. In this review, we firstly introduce the principle of imaging mass spectrometry and recent advances in the sample preparation method. Secondly, we present findings regarding biological samples, especially pathological ones. Finally, we discuss the limitations and problems of the IMS technique and clinical application, such as in drug development.

  11. Localization from Visual Landmarks on a Free-Flying Robot

    NASA Technical Reports Server (NTRS)

    Coltin, Brian; Fusco, Jesse; Moratto, Zack; Alexandrov, Oleg; Nakamura, Robert

    2016-01-01

    We present the localization approach for Astrobee, a new free-flying robot designed to navigate autonomously on the International Space Station (ISS). Astrobee will accommodate a variety of payloads and enable guest scientists to run experiments in zero-g, as well as assist astronauts and ground controllers. Astrobee will replace the SPHERES robots which currently operate on the ISS, whose use of fixed ultrasonic beacons for localization limits them to work in a 2 meter cube. Astrobee localizes with monocular vision and an IMU, without any environmental modifications. Visual features detected on a pre-built map, optical flow information, and IMU readings are all integrated into an extended Kalman filter (EKF) to estimate the robot pose. We introduce several modifications to the filter to make it more robust to noise, and extensively evaluate the localization algorithm.

  12. LEA Detection and Tracking Method for Color-Independent Visual-MIMO

    PubMed Central

    Kim, Jai-Eun; Kim, Ji-Won; Kim, Ki-Doo

    2016-01-01

    Communication performance in the color-independent visual-multiple input multiple output (visual-MIMO) technique is deteriorated by light emitting array (LEA) detection and tracking errors in the received image because the image sensor included in the camera must be used as the receiver in the visual-MIMO system. In this paper, in order to improve detection reliability, we first set up the color-space-based region of interest (ROI) in which an LEA is likely to be placed, and then use the Harris corner detection method. Next, we use Kalman filtering for robust tracking by predicting the most probable location of the LEA when the relative position between the camera and the LEA varies. In the last step of our proposed method, the perspective projection is used to correct the distorted image, which can improve the symbol decision accuracy. Finally, through numerical simulation, we show the possibility of robust detection and tracking of the LEA, which results in a symbol error rate (SER) performance improvement. PMID:27384563

  13. LEA Detection and Tracking Method for Color-Independent Visual-MIMO.

    PubMed

    Kim, Jai-Eun; Kim, Ji-Won; Kim, Ki-Doo

    2016-07-02

    Communication performance in the color-independent visual-multiple input multiple output (visual-MIMO) technique is deteriorated by light emitting array (LEA) detection and tracking errors in the received image because the image sensor included in the camera must be used as the receiver in the visual-MIMO system. In this paper, in order to improve detection reliability, we first set up the color-space-based region of interest (ROI) in which an LEA is likely to be placed, and then use the Harris corner detection method. Next, we use Kalman filtering for robust tracking by predicting the most probable location of the LEA when the relative position between the camera and the LEA varies. In the last step of our proposed method, the perspective projection is used to correct the distorted image, which can improve the symbol decision accuracy. Finally, through numerical simulation, we show the possibility of robust detection and tracking of the LEA, which results in a symbol error rate (SER) performance improvement.

  14. Detection of Visual Field Loss in Pituitary Disease: Peripheral Kinetic Versus Central Static

    PubMed Central

    Rowe, Fiona J.; Cheyne, Christopher P.; García-Fiñana, Marta; Noonan, Carmel P.; Howard, Claire; Smith, Jayne; Adeoye, Joanne

    2015-01-01

    Abstract Visual field assessment is an important clinical evaluation for eye disease and neurological injury. We evaluated Octopus semi-automated kinetic peripheral perimetry (SKP) and Humphrey static automated central perimetry for detection of neurological visual field loss in patients with pituitary disease. We carried out a prospective cross-sectional diagnostic accuracy study comparing Humphrey central 30-2 SITA threshold programme with a screening protocol for SKP on Octopus perimetry. Humphrey 24-2 data were extracted from 30-2 results. Results were independently graded for presence/absence of field defect plus severity of defect. Fifty patients (100 eyes) were recruited (25 males and 25 females), with mean age of 52.4 years (SD = 15.7). Order of perimeter assessment (Humphrey/Octopus first) and order of eye tested (right/left first) were randomised. The 30-2 programme detected visual field loss in 85%, the 24-2 programme in 80%, and the Octopus combined kinetic/static strategy in 100% of eyes. Peripheral visual field loss was missed by central threshold assessment. Qualitative comparison of type of visual field defect demonstrated a match between Humphrey and Octopus results in 58%, with a match for severity of defect in 50%. Tests duration was 9.34 minutes (SD = 2.02) for Humphrey 30-2 versus 10.79 minutes (SD = 4.06) for Octopus perimetry. Octopus semi-automated kinetic perimetry was found to be superior to central static testing for detection of pituitary disease-related visual field loss. Where reliant on Humphrey central static perimetry, the 30-2 programme is recommended over the 24-2 programme. Where kinetic perimetry is available, this is preferable to central static programmes for increased detection of peripheral visual field loss. PMID:27928344

  15. Fire protection for launch facilities using machine vision fire detection

    NASA Astrophysics Data System (ADS)

    Schwartz, Douglas B.

    1993-02-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  16. Real-time 3D reconstruction of road curvature in far look-ahead distance from analysis of image sequences

    NASA Astrophysics Data System (ADS)

    Behringer, Reinhold

    1995-12-01

    A system for visual road recognition in far look-ahead distance, implemented in the autonomous road vehicle VaMP (a passenger car), is described. Visual cues of a road in a video image are the bright lane markings and the edges formed at the road borders. In a distance of more than 100 m, the most relevant road cue is the homogeneous road area, limited by the two border edges. These cues can be detected by the image processing module KRONOS applying edge detection techniques and areal 2D segmentation based on resolution triangles (analogous to a resolution pyramid). An estimation process performs an update of a state vector, which describes spatial road shape and vehicle orientation relative to the road. This state vector is estimated every 40 ms by exploiting knowledge about the vehicle movement (spatio-temporal model of vehicle dynamics) and the road design rules (clothoidal segments). Kalman filter techniques are applied to obtain an optimal estimate of the state vector by evaluating the measurements of the road border positions in the image sequence taken by a set of CCD cameras. The road consists of segments with piecewise constant curvature parameters. The borders between these segments can be detected by applying methods which have been developed for detection of discontinuities during time-discrete measurements. The road recognition system has been tested in autonomous rides with VaMP on public Autobahnen in real traffic at speeds up to 130 km/h.

  17. Polyhydric polymer-functionalized fluorescent probe with enhanced aqueous solubility and specific ion recognition: A test strips-based fluorimetric strategy for the rapid and visual detection of Fe3+ ions.

    PubMed

    Duan, Zhiqiang; Zhang, Chunxian; Qiao, Yuchun; Liu, Fengjuan; Wang, Deyan; Wu, Mengfan; Wang, Ke; Lv, Xiaoxia; Kong, Xiangmu; Wang, Hua

    2017-08-01

    A polyhydric polymer-functionalized probe with enhanced aqueous solubility was designed initially by coupling 1-pyrenecarboxyaldehyde (Pyr) onto poly(vinyl alcohol) (PVA) via the one-step condensation reaction. Polyhydric PVA polymer chains could facilitate the Pyr fluorophore with largely improved aqueous solubility and especially strong cyan fluorescence. Importantly, the fluorescence of the PVA-Pyr probes could thereby be quenched specifically by Fe 3+ ions through the strong PVA-Fe 3+ interaction triggering the polymeric probe aggregation. Furthermore, a test strips-based fluorimetric method was developed with the stable and uniform probe distribution by taking advantage of the unique film-forming ability and the depression capacity of "coffee-stain" effects of PVA matrix. The as-developed test strips could allow for the rapid and visual detections of Fe 3+ ions simply by a dipping way, showing a linear concentration range of 5.00-300μM, with the detection limit of 0.73μM. Moreover, the proposed method was applied to the evaluation of Fe 3+ ions in natural water samples, showing the analysis performances better or comparable to those of current detection techniques. This test strips-based fluorimetric strategy promises the extensive applications for the rapid on-site monitoring of Fe 3+ ions in environmental water and the outdoor finding of the potential iron mines. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Fire protection for launch facilities using machine vision fire detection

    NASA Technical Reports Server (NTRS)

    Schwartz, Douglas B.

    1993-01-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  19. Microbleed detection using automated segmentation (MIDAS): a new method applicable to standard clinical MR images.

    PubMed

    Seghier, Mohamed L; Kolanko, Magdalena A; Leff, Alexander P; Jäger, Hans R; Gregoire, Simone M; Werring, David J

    2011-03-23

    Cerebral microbleeds, visible on gradient-recalled echo (GRE) T2* MRI, have generated increasing interest as an imaging marker of small vessel diseases, with relevance for intracerebral bleeding risk or brain dysfunction. Manual rating methods have limited reliability and are time-consuming. We developed a new method for microbleed detection using automated segmentation (MIDAS) and compared it with a validated visual rating system. In thirty consecutive stroke service patients, standard GRE T2* images were acquired and manually rated for microbleeds by a trained observer. After spatially normalizing each patient's GRE T2* images into a standard stereotaxic space, the automated microbleed detection algorithm (MIDAS) identified cerebral microbleeds by explicitly incorporating an "extra" tissue class for abnormal voxels within a unified segmentation-normalization model. The agreement between manual and automated methods was assessed using the intraclass correlation coefficient (ICC) and Kappa statistic. We found that MIDAS had generally moderate to good agreement with the manual reference method for the presence of lobar microbleeds (Kappa = 0.43, improved to 0.65 after manual exclusion of obvious artefacts). Agreement for the number of microbleeds was very good for lobar regions: (ICC = 0.71, improved to ICC = 0.87). MIDAS successfully detected all patients with multiple (≥2) lobar microbleeds. MIDAS can identify microbleeds on standard MR datasets, and with an additional rapid editing step shows good agreement with a validated visual rating system. MIDAS may be useful in screening for multiple lobar microbleeds.

  20. Improved detection following Neuro-Eye Therapy in patients with post-geniculate brain damage.

    PubMed

    Sahraie, Arash; Macleod, Mary-Joan; Trevethan, Ceri T; Robson, Siân E; Olson, John A; Callaghan, Paula; Yip, Brigitte

    2010-09-01

    Damage to the optic radiation or the occipital cortex results in loss of vision in the contralateral visual field, termed partial cortical blindness or hemianopia. Previously, we have demonstrated that stimulation in the field defect using visual stimuli with optimal properties for blindsight detection can lead to increases in visual sensitivity within the blind field of a group of patients. The present study was aimed to extend the previous work by investigating the effect of positive feedback on recovery of visual sensitivity. Patients' abilities for detection of a range of spatial frequencies within their field defect were determined using a temporal two-alternative forced-choice technique, before and after a period of visual training (n = 4). Patients underwent Neuro-Eye Therapy which involved detection of temporally modulated spatial grating patches at specific retinal locations within their field defect. Three patients showed improved detection ability following visual training. Based on our previous studies, we had hypothesised that should the occipital brain lesion extend anteriorly to the thalamus, little recovery would be expected. Here, we describe one such case who showed no improvements after extensive training. The present study provides further evidence that recovery (a) can be gradual and may require a large number of training sessions (b) can be accelerated using positive feedback and (c) may be less likely to take place if the occipital damage extends anteriorly to the thalamus.

Top