Sample records for visual evaluation methods

  1. Evaluation of Visualization Software

    NASA Technical Reports Server (NTRS)

    Globus, Al; Uselton, Sam

    1995-01-01

    Visualization software is widely used in scientific and engineering research. But computed visualizations can be very misleading, and the errors are easy to miss. We feel that the software producing the visualizations must be thoroughly evaluated and the evaluation process as well as the results must be made available. Testing and evaluation of visualization software is not a trivial problem. Several methods used in testing other software are helpful, but these methods are (apparently) often not used. When they are used, the description and results are generally not available to the end user. Additional evaluation methods specific to visualization must also be developed. We present several useful approaches to evaluation, ranging from numerical analysis of mathematical portions of algorithms to measurement of human performance while using visualization systems. Along with this brief survey, we present arguments for the importance of evaluations and discussions of appropriate use of some methods.

  2. Evaluation of angiogram visualization methods for fast and reliable aneurysm diagnosis

    NASA Astrophysics Data System (ADS)

    Lesar, Žiga; Bohak, Ciril; Marolt, Matija

    2015-03-01

    In this paper we present the results of an evaluation of different visualization methods for angiogram volumetric data-ray casting, marching cubes, and multi-level partition of unity implicits. There are several options available with ray-casting: isosurface extraction, maximum intensity projection and alpha compositing, each producing fundamentally different results. Different visualization methods are suitable for different needs, so this choice is crucial in diagnosis and decision making processes. We also evaluate visual effects such as ambient occlusion, screen space ambient occlusion, and depth of field. Some visualization methods include transparency, so we address the question of relevancy of this additional visual information. We employ transfer functions to map data values to color and transparency, allowing us to view or hide particular tissues. All the methods presented in this paper were developed using OpenCL, striving for real-time rendering and quality interaction. An evaluation has been conducted to assess the suitability of the visualization methods. Results show superiority of isosurface extraction with ambient occlusion effects. Visual effects may positively or negatively affect perception of depth, motion, and relative positions in space.

  3. Evaluation of Visualization Tools for Computer Network Defense Analysts: Display Design, Methods, and Results for a User Study

    DTIC Science & Technology

    2016-11-01

    Display Design, Methods , and Results for a User Study by Christopher J Garneau and Robert F Erbacher Approved for public...NOV 2016 US Army Research Laboratory Evaluation of Visualization Tools for Computer Network Defense Analysts: Display Design, Methods ...January 2013–September 2015 4. TITLE AND SUBTITLE Evaluation of Visualization Tools for Computer Network Defense Analysts: Display Design, Methods

  4. Toward Mixed Method Evaluations of Scientific Visualizations and Design Process as an Evaluation Tool.

    PubMed

    Jackson, Bret; Coffey, Dane; Thorson, Lauren; Schroeder, David; Ellingson, Arin M; Nuckley, David J; Keefe, Daniel F

    2012-10-01

    In this position paper we discuss successes and limitations of current evaluation strategies for scientific visualizations and argue for embracing a mixed methods strategy of evaluation. The most novel contribution of the approach that we advocate is a new emphasis on employing design processes as practiced in related fields (e.g., graphic design, illustration, architecture) as a formalized mode of evaluation for data visualizations. To motivate this position we describe a series of recent evaluations of scientific visualization interfaces and computer graphics strategies conducted within our research group. Complementing these more traditional evaluations our visualization research group also regularly employs sketching, critique, and other design methods that have been formalized over years of practice in design fields. Our experience has convinced us that these activities are invaluable, often providing much more detailed evaluative feedback about our visualization systems than that obtained via more traditional user studies and the like. We believe that if design-based evaluation methodologies (e.g., ideation, sketching, critique) can be taught and embraced within the visualization community then these may become one of the most effective future strategies for both formative and summative evaluations.

  5. Toward Mixed Method Evaluations of Scientific Visualizations and Design Process as an Evaluation Tool

    PubMed Central

    Jackson, Bret; Coffey, Dane; Thorson, Lauren; Schroeder, David; Ellingson, Arin M.; Nuckley, David J.

    2017-01-01

    In this position paper we discuss successes and limitations of current evaluation strategies for scientific visualizations and argue for embracing a mixed methods strategy of evaluation. The most novel contribution of the approach that we advocate is a new emphasis on employing design processes as practiced in related fields (e.g., graphic design, illustration, architecture) as a formalized mode of evaluation for data visualizations. To motivate this position we describe a series of recent evaluations of scientific visualization interfaces and computer graphics strategies conducted within our research group. Complementing these more traditional evaluations our visualization research group also regularly employs sketching, critique, and other design methods that have been formalized over years of practice in design fields. Our experience has convinced us that these activities are invaluable, often providing much more detailed evaluative feedback about our visualization systems than that obtained via more traditional user studies and the like. We believe that if design-based evaluation methodologies (e.g., ideation, sketching, critique) can be taught and embraced within the visualization community then these may become one of the most effective future strategies for both formative and summative evaluations. PMID:28944349

  6. A Recommended Engineering Application of the Method for Evaluating the Visual Significance of Reflected Glare.

    ERIC Educational Resources Information Center

    Blackwell, H. Richard

    1963-01-01

    An application method for evaluating the visual significance of reflected glare is described, based upon a number of decisions with respect to the relative importance of various aspects of visual performance. A standardized procedure for evaluating the overall effectiveness of lighting from photometric data on materials or installations is needed…

  7. Statistical modeling for visualization evaluation through data fusion.

    PubMed

    Chen, Xiaoyu; Jin, Ran

    2017-11-01

    There is a high demand of data visualization providing insights to users in various applications. However, a consistent, online visualization evaluation method to quantify mental workload or user preference is lacking, which leads to an inefficient visualization and user interface design process. Recently, the advancement of interactive and sensing technologies makes the electroencephalogram (EEG) signals, eye movements as well as visualization logs available in user-centered evaluation. This paper proposes a data fusion model and the application procedure for quantitative and online visualization evaluation. 15 participants joined the study based on three different visualization designs. The results provide a regularized regression model which can accurately predict the user's evaluation of task complexity, and indicate the significance of all three types of sensing data sets for visualization evaluation. This model can be widely applied to data visualization evaluation, and other user-centered designs evaluation and data analysis in human factors and ergonomics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. An Evaluation of the Conservative Dual-Criterion Method for Teaching University Students to Visually Inspect AB-Design Graphs

    ERIC Educational Resources Information Center

    Stewart, Kelise K.; Carr, James E.; Brandt, Charles W.; McHenry, Meade M.

    2007-01-01

    The present study evaluated the effects of both a traditional lecture and the conservative dual-criterion (CDC) judgment aid on the ability of 6 university students to visually inspect AB-design line graphs. The traditional lecture reliably failed to improve visual inspection accuracy, whereas the CDC method substantially improved the performance…

  9. Degradation of learned skills. Static practice effectiveness for visual approach and landing skill retention

    NASA Technical Reports Server (NTRS)

    Sitterley, T. E.

    1974-01-01

    The effectivess of an improved static retraining method was evaluated for a simulated space vehicle approach and landing under instrument and visual flight conditions. Experienced pilots were trained and then tested after 4 months without flying to compare their performance using the improved method with three methods previously evaluated. Use of the improved static retraining method resulted in no practical or significant skill degradation and was found to be even more effective than methods using a dynamic presentation of visual cues. The results suggested that properly structured open loop methods of flight control task retraining are feasible.

  10. Estimating mast production: an evaluation of visual surveys and comparison with seed traps using white oaks

    Treesearch

    Roger W. Perry; Ronald E. Thill

    1999-01-01

    Perry and Thill compared five types of visual mast surveyed with seed trap data from 105 white oaks (Quercus alba L.) during 1996-1997 in the Ouachita Mountains of Arkansas. They also evaluated these visual survey methods for their usefulness in detecting differences in acorn density among areas. Indices derived from all five methods were highly...

  11. Evolution of a visual impact model to evaluate nuclear plant siting and design option

    Treesearch

    Brian A. Gray; John Ady; Grant R. Jones

    1979-01-01

    The development of a visual impact method- elegy is reviewed from first concepts (1973) to application.3/ The method can be used to train evaluators to use explicit criteria (vividness, intactness and unity) to assess change in a setting's visual quality as the result of construction of a nuclear facility, or any other visible alteration. Slides of "before...

  12. Evaluation of in-vehicle HMI using occlusion techniques: experimental results and practical implications.

    PubMed

    Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus

    2004-05-01

    Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.

  13. Modeling and evaluating user behavior in exploratory visual analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Khairi; Johnson, Andrew E.; Papka, Michael E.

    Empirical evaluation methods for visualizations have traditionally focused on assessing the outcome of the visual analytic process as opposed to characterizing how that process unfolds. There are only a handful of methods that can be used to systematically study how people use visualizations, making it difficult for researchers to capture and characterize the subtlety of cognitive and interaction behaviors users exhibit during visual analysis. To validate and improve visualization design, however, it is important for researchers to be able to assess and understand how users interact with visualization systems under realistic scenarios. This paper presents a methodology for modeling andmore » evaluating the behavior of users in exploratory visual analysis. We model visual exploration using a Markov chain process comprising transitions between mental, interaction, and computational states. These states and the transitions between them can be deduced from a variety of sources, including verbal transcripts, videos and audio recordings, and log files. This model enables the evaluator to characterize the cognitive and computational processes that are essential to insight acquisition in exploratory visual analysis, and reconstruct the dynamics of interaction between the user and the visualization system. We illustrate this model with two exemplar user studies, and demonstrate the qualitative and quantitative analytical tools it affords.« less

  14. Physical Evaluation of Cleaning Performance: We Are Only Fooling Ourselves

    NASA Technical Reports Server (NTRS)

    Pratz, Earl; McCool, A. (Technical Monitor)

    2000-01-01

    Surface cleaning processes are normally evaluated using visual physical properties such as discolorations, streaking, staining and water-break-free conditions. There is an assumption that these physical methods will evaluate all surfaces all the time for all subsequent operations. We have found that these physical methods are lacking in sensitivity and selectivity with regard to surface residues and subsequent process performance. We will report several conditions where evaluations using visual physical properties are lacking. We will identify possible alternative methods and future needs for surface evaluations.

  15. Perception, Cognition, and Effectiveness of Visualizations with Applications in Science and Engineering

    NASA Astrophysics Data System (ADS)

    Borkin, Michelle A.

    Visualization is a powerful tool for data exploration and analysis. With data ever-increasing in quantity and becoming integrated into our daily lives, having effective visualizations is necessary. But how does one design an effective visualization? To answer this question we need to understand how humans perceive, process, and understand visualizations. Through visualization evaluation studies we can gain deeper insight into the basic perception and cognition theory of visualizations, both through domain-specific case studies as well as generalized laboratory experiments. This dissertation presents the results of four evaluation studies, each of which contributes new knowledge to the theory of perception and cognition of visualizations. The results of these studies include a deeper clearer understanding of how color, data representation dimensionality, spatial layout, and visual complexity affect a visualization's effectiveness, as well as how visualization types and visual attributes affect the memorability of a visualization. We first present the results of two domain-specific case study evaluations. The first study is in the field of biomedicine in which we developed a new heart disease diagnostic tool, and conducted a study to evaluate the effectiveness of 2D versus 3D data representations as well as color maps. In the second study, we developed a new visualization tool for filesystem provenance data with applications in computer science and the sciences more broadly. We additionally developed a new time-based hierarchical node grouping method. We then conducted a study to evaluate the effectiveness of the new tool with its radial layout versus the conventional node-link diagram, and the new node grouping method. Finally, we discuss the results of two generalized studies designed to understand what makes a visualization memorable. In the first evaluation we focused on visualization memorability and conducted an online study using Amazon's Mechanical Turk with hundreds of users and thousands of visualizations. For the second evaluation we designed an eye-tracking laboratory study to gain insight into precisely which elements of a visualization contribute to memorability as well as visualization recognition and recall.

  16. Color coding of control room displays: the psychocartography of visual layering effects.

    PubMed

    Van Laar, Darren; Deshe, Ofer

    2007-06-01

    To evaluate which of three color coding methods (monochrome, maximally discriminable, and visual layering) used to code four types of control room display format (bars, tables, trend, mimic) was superior in two classes of task (search, compare). It has recently been shown that color coding of visual layers, as used in cartography, may be used to color code any type of information display, but this has yet to be fully evaluated. Twenty-four people took part in a 2 (task) x 3 (coding method) x 4 (format) wholly repeated measures design. The dependent variables assessed were target location reaction time, error rates, workload, and subjective feedback. Overall, the visual layers coding method produced significantly faster reaction times than did the maximally discriminable and the monochrome methods for both the search and compare tasks. No significant difference in errors was observed between conditions for either task type. Significantly less perceived workload was experienced with the visual layers coding method, which was also rated more highly than the other coding methods on a 14-item visual display quality questionnaire. The visual layers coding method is superior to other color coding methods for control room displays when the method supports the user's task. The visual layers color coding method has wide applicability to the design of all complex information displays utilizing color coding, from the most maplike (e.g., air traffic control) to the most abstract (e.g., abstracted ecological display).

  17. Towards a Visual Quality Metric for Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1998-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  18. Automated Assessment of Visual Quality of Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Ellis, Stephen R. (Technical Monitor)

    1997-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images[1-4]. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  19. Modeling human comprehension of data visualizations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzen, Laura E.; Haass, Michael Joseph; Divis, Kristin Marie

    This project was inspired by two needs. The first is a need for tools to help scientists and engineers to design effective data visualizations for communicating information, whether to the user of a system, an analyst who must make decisions based on complex data, or in the context of a technical report or publication. Most scientists and engineers are not trained in visualization design, and they could benefit from simple metrics to assess how well their visualization's design conveys the intended message. In other words, will the most important information draw the viewer's attention? The second is the need formore » cognition-based metrics for evaluating new types of visualizations created by researchers in the information visualization and visual analytics communities. Evaluating visualizations is difficult even for experts. However, all visualization methods and techniques are intended to exploit the properties of the human visual system to convey information efficiently to a viewer. Thus, developing evaluation methods that are rooted in the scientific knowledge of the human visual system could be a useful approach. In this project, we conducted fundamental research on how humans make sense of abstract data visualizations, and how this process is influenced by their goals and prior experience. We then used that research to develop a new model, the Data Visualization Saliency Model, that can make accurate predictions about which features in an abstract visualization will draw a viewer's attention. The model is an evaluation tool that can address both of the needs described above, supporting both visualization research and Sandia mission needs.« less

  20. New insight in spiral drawing analysis methods - Application to action tremor quantification.

    PubMed

    Legrand, André Pierre; Rivals, Isabelle; Richard, Aliénor; Apartis, Emmanuelle; Roze, Emmanuel; Vidailhet, Marie; Meunier, Sabine; Hainque, Elodie

    2017-10-01

    Spiral drawing is one of the standard tests used to assess tremor severity for the clinical evaluation of medical treatments. Tremor severity is estimated through visual rating of the drawings by movement disorders experts. Different approaches based on the mathematical signal analysis of the recorded spiral drawings were proposed to replace this rater dependent estimate. The objective of the present study is to propose new numerical methods and to evaluate them in terms of agreement with visual rating and reproducibility. Series of spiral drawings of patients with essential tremor were visually rated by a board of experts. In addition to the usual velocity analysis, three new numerical methods were tested and compared, namely static and dynamic unraveling, and empirical mode decomposition. The reproducibility of both visual and numerical ratings was estimated, and their agreement was evaluated. The statistical analysis demonstrated excellent agreement between visual and numerical ratings, and more reproducible results with numerical methods than with visual ratings. The velocity method and the new numerical methods are in good agreement. Among the latter, static and dynamic unravelling both display a smaller dispersion and are easier for automatic analysis. The reliable scores obtained through the proposed numerical methods allow considering that their implementation on a digitized tablet, be it connected with a computer or independent, provides an efficient automatic tool for tremor severity assessment. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  1. Method for evaluation of human induced pluripotent stem cell quality using image analysis based on the biological morphology of cells.

    PubMed

    Wakui, Takashi; Matsumoto, Tsuyoshi; Matsubara, Kenta; Kawasaki, Tomoyuki; Yamaguchi, Hiroshi; Akutsu, Hidenori

    2017-10-01

    We propose an image analysis method for quality evaluation of human pluripotent stem cells based on biologically interpretable features. It is important to maintain the undifferentiated state of induced pluripotent stem cells (iPSCs) while culturing the cells during propagation. Cell culture experts visually select good quality cells exhibiting the morphological features characteristic of undifferentiated cells. Experts have empirically determined that these features comprise prominent and abundant nucleoli, less intercellular spacing, and fewer differentiating cellular nuclei. We quantified these features based on experts' visual inspection of phase contrast images of iPSCs and found that these features are effective for evaluating iPSC quality. We then developed an iPSC quality evaluation method using an image analysis technique. The method allowed accurate classification, equivalent to visual inspection by experts, of three iPSC cell lines.

  2. Image segmentation evaluation for very-large datasets

    NASA Astrophysics Data System (ADS)

    Reeves, Anthony P.; Liu, Shuang; Xie, Yiting

    2016-03-01

    With the advent of modern machine learning methods and fully automated image analysis there is a need for very large image datasets having documented segmentations for both computer algorithm training and evaluation. Current approaches of visual inspection and manual markings do not scale well to big data. We present a new approach that depends on fully automated algorithm outcomes for segmentation documentation, requires no manual marking, and provides quantitative evaluation for computer algorithms. The documentation of new image segmentations and new algorithm outcomes are achieved by visual inspection. The burden of visual inspection on large datasets is minimized by (a) customized visualizations for rapid review and (b) reducing the number of cases to be reviewed through analysis of quantitative segmentation evaluation. This method has been applied to a dataset of 7,440 whole-lung CT images for 6 different segmentation algorithms designed to fully automatically facilitate the measurement of a number of very important quantitative image biomarkers. The results indicate that we could achieve 93% to 99% successful segmentation for these algorithms on this relatively large image database. The presented evaluation method may be scaled to much larger image databases.

  3. The Levels of Visual Framing

    ERIC Educational Resources Information Center

    Rodriguez, Lulu; Dimitrova, Daniela V.

    2011-01-01

    While framing research has centered mostly on the evaluations of media texts, visual news discourse has remained relatively unexamined. This study surveys the visual framing techniques and methods employed in previous studies and proposes a four-tiered model of identifying and analyzing visual frames: (1) visuals as denotative systems, (2) visuals…

  4. Visual quality evaluation of urban commercial streetscape for the development of landscape visual planning system in provincial street corridors in Malang, Indonesia

    NASA Astrophysics Data System (ADS)

    Santosa, H.; Ernawati, J.; Wulandari, L. D.

    2018-03-01

    The visual aesthetic experience in urban spaces is important in establishing a comfortable and satisfying experience for the community. The embodiment of a good visual image of urban space will encourage the emergence of positive perceptions and meanings stimulating the community to produce a good reaction to its urban space. Moreover, to establish a Good Governance in urban planning and design, it is necessary to boost and promote a community participation in the process of controlling the visual quality of urban space through the visual quality evaluation on urban street corridors. This study is an early stage as part of the development of ‘Landscape Visual Planning System’ on the commercial street corridor in Malang. Accordingly, the research aims to evaluate the physical characteristics and the public preferences of the spatial and visual aspects in five provincial road corridors in Malang. This study employs a field survey methods, and an environmental aesthetics approach through semantic differential method. The result of the identification of physical characteristics and the assessment of public preferences on the spatial and visual aspects of the five provincial streets serve as the basis for constructing the 3d interactive simulation scenarios in the Landscape Visual Planning System.

  5. Decoding the time-course of object recognition in the human brain: From visual features to categorical decisions.

    PubMed

    Contini, Erika W; Wardle, Susan G; Carlson, Thomas A

    2017-10-01

    Visual object recognition is a complex, dynamic process. Multivariate pattern analysis methods, such as decoding, have begun to reveal how the brain processes complex visual information. Recently, temporal decoding methods for EEG and MEG have offered the potential to evaluate the temporal dynamics of object recognition. Here we review the contribution of M/EEG time-series decoding methods to understanding visual object recognition in the human brain. Consistent with the current understanding of the visual processing hierarchy, low-level visual features dominate decodable object representations early in the time-course, with more abstract representations related to object category emerging later. A key finding is that the time-course of object processing is highly dynamic and rapidly evolving, with limited temporal generalisation of decodable information. Several studies have examined the emergence of object category structure, and we consider to what degree category decoding can be explained by sensitivity to low-level visual features. Finally, we evaluate recent work attempting to link human behaviour to the neural time-course of object processing. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Scientific Process Flowchart Assessment (SPFA): A Method for Evaluating Changes in Understanding and Visualization of the Scientific Process in a Multidisciplinary Student Population

    ERIC Educational Resources Information Center

    Wilson, Kristy J.; Rigakos, Bessie

    2016-01-01

    The scientific process is nonlinear, unpredictable, and ongoing. Assessing the nature of science is difficult with methods that rely on Likert-scale or multiple-choice questions. This study evaluated conceptions about the scientific process using student-created visual representations that we term "flowcharts." The methodology,…

  7. An Evaluation of a Computer-Based Training on the Visual Analysis of Single-Subject Data

    ERIC Educational Resources Information Center

    Snyder, Katie

    2013-01-01

    Visual analysis is the primary method of analyzing data in single-subject methodology, which is the predominant research method used in the fields of applied behavior analysis and special education. Previous research on the reliability of visual analysis suggests that judges often disagree about what constitutes an intervention effect. Considering…

  8. Visualization of Data Regarding Infections Using Eye Tracking Techniques

    PubMed Central

    Yoon, Sunmoo; Cohen, Bevin; Cato, Kenrick D.; Liu, Jianfang; Larson, Elaine L.

    2016-01-01

    Objective To evaluate ease of use and usefulness for nurses of visualizations of infectious disease transmission in a hospital. Design An observational study was used to evaluate perceptions of several visualizations of data extracted from electronic health records designed using a participatory approach. Twelve nurses in the master’s program in an urban research-intensive nursing school participated in May 2015. Methods A convergent parallel mixed method was used to evaluate nurses’ perceptions on ease of use and usefulness of five visualization conveying trends in hospital infection transmission applying think-aloud, interview, and eye-tracking techniques. Findings Subjective data from the interview and think-aloud techniques indicated that participants preferred the traditional line graphs in simple data representation due to their familiarity, clarity, and easiness to read. An objective quantitative measure of eye movement analysis (444,421 gaze events) identified a high degree of participants’ attention span in infographics in all three scenarios. All participants responded with the correct answer within 1 min in comprehensive tests. Conclusions A user-centric approach was effective in developing and evaluating visualizations for hospital infection transmission. For the visualizations designed by the users, the participants were easily able to comprehend the infection visualizations on both line graphs and infographics for simple visualization. The findings from the objective comprehension test and eye movement and subjective attitudes support the feasibility of integrating user-centric visualization designs into electronic health records, which may inspire clinicians to be mindful of hospital infection transmission. Future studies are needed to investigate visualizations and motivation, and the effectiveness of visualization on infection rate. Clinical Relevance This study designed visualization images using clinical data from electronic health records applying a user-centric approach. The design insights can be applied for visualizing patient data in electronic health records. PMID:27061619

  9. Dictionary Pruning with Visual Word Significance for Medical Image Retrieval

    PubMed Central

    Zhang, Fan; Song, Yang; Cai, Weidong; Hauptmann, Alexander G.; Liu, Sidong; Pujol, Sonia; Kikinis, Ron; Fulham, Michael J; Feng, David Dagan; Chen, Mei

    2016-01-01

    Content-based medical image retrieval (CBMIR) is an active research area for disease diagnosis and treatment but it can be problematic given the small visual variations between anatomical structures. We propose a retrieval method based on a bag-of-visual-words (BoVW) to identify discriminative characteristics between different medical images with Pruned Dictionary based on Latent Semantic Topic description. We refer to this as the PD-LST retrieval. Our method has two main components. First, we calculate a topic-word significance value for each visual word given a certain latent topic to evaluate how the word is connected to this latent topic. The latent topics are learnt, based on the relationship between the images and words, and are employed to bridge the gap between low-level visual features and high-level semantics. These latent topics describe the images and words semantically and can thus facilitate more meaningful comparisons between the words. Second, we compute an overall-word significance value to evaluate the significance of a visual word within the entire dictionary. We designed an iterative ranking method to measure overall-word significance by considering the relationship between all latent topics and words. The words with higher values are considered meaningful with more significant discriminative power in differentiating medical images. We evaluated our method on two public medical imaging datasets and it showed improved retrieval accuracy and efficiency. PMID:27688597

  10. Dictionary Pruning with Visual Word Significance for Medical Image Retrieval.

    PubMed

    Zhang, Fan; Song, Yang; Cai, Weidong; Hauptmann, Alexander G; Liu, Sidong; Pujol, Sonia; Kikinis, Ron; Fulham, Michael J; Feng, David Dagan; Chen, Mei

    2016-02-12

    Content-based medical image retrieval (CBMIR) is an active research area for disease diagnosis and treatment but it can be problematic given the small visual variations between anatomical structures. We propose a retrieval method based on a bag-of-visual-words (BoVW) to identify discriminative characteristics between different medical images with Pruned Dictionary based on Latent Semantic Topic description. We refer to this as the PD-LST retrieval. Our method has two main components. First, we calculate a topic-word significance value for each visual word given a certain latent topic to evaluate how the word is connected to this latent topic. The latent topics are learnt, based on the relationship between the images and words, and are employed to bridge the gap between low-level visual features and high-level semantics. These latent topics describe the images and words semantically and can thus facilitate more meaningful comparisons between the words. Second, we compute an overall-word significance value to evaluate the significance of a visual word within the entire dictionary. We designed an iterative ranking method to measure overall-word significance by considering the relationship between all latent topics and words. The words with higher values are considered meaningful with more significant discriminative power in differentiating medical images. We evaluated our method on two public medical imaging datasets and it showed improved retrieval accuracy and efficiency.

  11. Subjective and objective evaluation of visual fatigue on viewing 3D display continuously

    NASA Astrophysics Data System (ADS)

    Wang, Danli; Xie, Yaohua; Yang, Xinpan; Lu, Yang; Guo, Anxiang

    2015-03-01

    In recent years, three-dimensional (3D) displays become more and more popular in many fields. Although they can provide better viewing experience, they cause extra problems, e.g., visual fatigue. Subjective or objective methods are usually used in discrete viewing processes to evaluate visual fatigue. However, little research combines subjective indicators and objective ones in an entirely continuous viewing process. In this paper, we propose a method to evaluate real-time visual fatigue both subjectively and objectively. Subjects watch stereo contents on a polarized 3D display continuously. Visual Reaction Time (VRT), Critical Flicker Frequency (CFF), Punctum Maximum Accommodation (PMA) and subjective scores of visual fatigue are collected before and after viewing. During the viewing process, the subjects rate the visual fatigue whenever it changes, without breaking the viewing process. At the same time, the blink frequency (BF) and percentage of eye closure (PERCLOS) of each subject is recorded for comparison to a previous research. The results show that the subjective visual fatigue and PERCLOS increase with time and they are greater in a continuous process than a discrete one. The BF increased with time during the continuous viewing process. Besides, the visual fatigue also induced significant changes of VRT, CFF and PMA.

  12. Accuracy of the visual estimation method as a predictor of food intake in Alzheimer's patients provided with different types of food.

    PubMed

    Amano, Nobuko; Nakamura, Tomiyo

    2018-02-01

    The visual estimation method is commonly used in hospitals and other care facilities to evaluate food intake through estimation of plate waste. In Japan, no previous studies have investigated the validity and reliability of this method under the routine conditions of a hospital setting. The present study aimed to evaluate the validity and reliability of the visual estimation method, in long-term inpatients with different levels of eating disability caused by Alzheimer's disease. The patients were provided different therapeutic diets presented in various food types. This study was performed between February and April 2013, and 82 patients with Alzheimer's disease were included. Plate waste was evaluated for the 3 main daily meals, for a total of 21 days, 7 consecutive days during each of the 3 months, originating a total of 4851 meals, from which 3984 were included. Plate waste was measured by the nurses through the visual estimation method, and by the hospital's registered dietitians through the actual measurement method. The actual measurement method was first validated to serve as a reference, and the level of agreement between both methods was then determined. The month, time of day, type of food provided, and patients' physical characteristics were considered for analysis. For the 3984 meals included in the analysis, the level of agreement between the measurement methods was 78.4%. Disagreement of measurements consisted of 3.8% of underestimation and 17.8% of overestimation. Cronbach's α (0.60, P < 0.001) indicated that the reliability of the visual estimation method was within the acceptable range. The visual estimation method was found to be a valid and reliable method for estimating food intake in patients with different levels of eating impairment. The successful implementation and use of the method depends upon adequate training and motivation of the nurses and care staff involved. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  13. Appraising the reliability of visual impact assessment methods

    Treesearch

    Nickolaus R. Feimer; Kenneth H. Craik; Richard C. Smardon; Stephen R.J. Sheppard

    1979-01-01

    This paper presents the research approach and selected results of an empirical investigation aimed at the evaluation of selected observer-based visual impact assessment (VIA) methods. The VIA methods under examination were chosen to cover a range of VIA methods currently in use in both applied and research settings. Variation in three facets of VIA methods were...

  14. Retrieval evaluation and distance learning from perceived similarity between endomicroscopy videos.

    PubMed

    André, Barbara; Vercauteren, Tom; Buchner, Anna M; Wallace, Michael B; Ayache, Nicholas

    2011-01-01

    Evaluating content-based retrieval (CBR) is challenging because it requires an adequate ground-truth. When the available groundtruth is limited to textual metadata such as pathological classes, retrieval results can only be evaluated indirectly, for example in terms of classification performance. In this study we first present a tool to generate perceived similarity ground-truth that enables direct evaluation of endomicroscopic video retrieval. This tool uses a four-points Likert scale and collects subjective pairwise similarities perceived by multiple expert observers. We then evaluate against the generated ground-truth a previously developed dense bag-of-visual-words method for endomicroscopic video retrieval. Confirming the results of previous indirect evaluation based on classification, our direct evaluation shows that this method significantly outperforms several other state-of-the-art CBR methods. In a second step, we propose to improve the CBR method by learning an adjusted similarity metric from the perceived similarity ground-truth. By minimizing a margin-based cost function that differentiates similar and dissimilar video pairs, we learn a weight vector applied to the visual word signatures of videos. Using cross-validation, we demonstrate that the learned similarity distance is significantly better correlated with the perceived similarity than the original visual-word-based distance.

  15. Visual analytics for aviation safety: A collaborative approach to sensemaking

    NASA Astrophysics Data System (ADS)

    Wade, Andrew

    Visual analytics, the "science of analytical reasoning facilitated by interactive visual interfaces", is more than just visualization. Understanding the human reasoning process is essential for designing effective visualization tools and providing correct analyses. This thesis describes the evolution, application and evaluation of a new method for studying analytical reasoning that we have labeled paired analysis. Paired analysis combines subject matter experts (SMEs) and tool experts (TE) in an analytic dyad, here used to investigate aircraft maintenance and safety data. The method was developed and evaluated using interviews, pilot studies and analytic sessions during an internship at the Boeing Company. By enabling a collaborative approach to sensemaking that can be captured by researchers, paired analysis yielded rich data on human analytical reasoning that can be used to support analytic tool development and analyst training. Keywords: visual analytics, paired analysis, sensemaking, boeing, collaborative analysis.

  16. Evaluation of a visual layering methodology for colour coding control room displays.

    PubMed

    Van Laar, Darren; Deshe, Ofer

    2002-07-01

    Eighteen people participated in an experiment in which they were asked to search for targets on control room like displays which had been produced using three different coding methods. The monochrome coding method displayed the information in black and white only, the maximally discriminable method contained colours chosen for their high perceptual discriminability, the visual layers method contained colours developed from psychological and cartographic principles which grouped information into a perceptual hierarchy. The visual layers method produced significantly faster search times than the other two coding methods which did not differ significantly from each other. Search time also differed significantly for presentation order and for the method x order interaction. There was no significant difference between the methods in the number of errors made. Participants clearly preferred the visual layers coding method. Proposals are made for the design of experiments to further test and develop the visual layers colour coding methodology.

  17. Visual fatigue modeling for stereoscopic video shot based on camera motion

    NASA Astrophysics Data System (ADS)

    Shi, Guozhong; Sang, Xinzhu; Yu, Xunbo; Liu, Yangdong; Liu, Jing

    2014-11-01

    As three-dimensional television (3-DTV) and 3-D movie become popular, the discomfort of visual feeling limits further applications of 3D display technology. The cause of visual discomfort from stereoscopic video conflicts between accommodation and convergence, excessive binocular parallax, fast motion of objects and so on. Here, a novel method for evaluating visual fatigue is demonstrated. Influence factors including spatial structure, motion scale and comfortable zone are analyzed. According to the human visual system (HVS), people only need to converge their eyes to the specific objects for static cameras and background. Relative motion should be considered for different camera conditions determining different factor coefficients and weights. Compared with the traditional visual fatigue prediction model, a novel visual fatigue predicting model is presented. Visual fatigue degree is predicted using multiple linear regression method combining with the subjective evaluation. Consequently, each factor can reflect the characteristics of the scene, and the total visual fatigue score can be indicated according to the proposed algorithm. Compared with conventional algorithms which ignored the status of the camera, our approach exhibits reliable performance in terms of correlation with subjective test results.

  18. Infrared and visual image fusion method based on discrete cosine transform and local spatial frequency in discrete stationary wavelet transform domain

    NASA Astrophysics Data System (ADS)

    Jin, Xin; Jiang, Qian; Yao, Shaowen; Zhou, Dongming; Nie, Rencan; Lee, Shin-Jye; He, Kangjian

    2018-01-01

    In order to promote the performance of infrared and visual image fusion and provide better visual effects, this paper proposes a hybrid fusion method for infrared and visual image by the combination of discrete stationary wavelet transform (DSWT), discrete cosine transform (DCT) and local spatial frequency (LSF). The proposed method has three key processing steps. Firstly, DSWT is employed to decompose the important features of the source image into a series of sub-images with different levels and spatial frequencies. Secondly, DCT is used to separate the significant details of the sub-images according to the energy of different frequencies. Thirdly, LSF is applied to enhance the regional features of DCT coefficients, and it can be helpful and useful for image feature extraction. Some frequently-used image fusion methods and evaluation metrics are employed to evaluate the validity of the proposed method. The experiments indicate that the proposed method can achieve good fusion effect, and it is more efficient than other conventional image fusion methods.

  19. Evaluating wood failure in plywood shear by optical image analysis

    Treesearch

    Charles W. McMillin

    1984-01-01

    This exploratory study evaulates the potential of using an automatic image analysis method to measure percent wood failure in plywood shear specimens. The results suggest that this method my be as accurate as the visual method in tracking long-term gluebond quality. With further refinement, the method could lead to automated equipment replacing the subjective visual...

  20. A method to determine the impact of reduced visual function on nodule detection performance.

    PubMed

    Thompson, J D; Lança, C; Lança, L; Hogg, P

    2017-02-01

    In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (-1.00 D and -2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1-4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to -1.00 D and for one observer when defocussed to -2.00 D. Stereoacuity was unacceptable for one observer when defocussed to -2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  1. A novel wide-field-of-view display method with higher central resolution for hyper-realistic head dome projector

    NASA Astrophysics Data System (ADS)

    Hotta, Aira; Sasaki, Takashi; Okumura, Haruhiko

    2007-02-01

    In this paper, we propose a novel display method to realize a high-resolution image in a central visual field for a hyper-realistic head dome projector. The method uses image processing based on the characteristics of human vision, namely, high central visual acuity and low peripheral visual acuity, and pixel shift technology, which is one of the resolution-enhancing technologies for projectors. The projected image with our method is a fine wide-viewing-angle image with high definition in the central visual field. We evaluated the psychological effects of the projected images with our method in terms of sensation of reality. According to the result, we obtained 1.5 times higher resolution in the central visual field and a greater sensation of reality by using our method.

  2. Human Computation in Visualization: Using Purpose Driven Games for Robust Evaluation of Visualization Algorithms.

    PubMed

    Ahmed, N; Zheng, Ziyi; Mueller, K

    2012-12-01

    Due to the inherent characteristics of the visualization process, most of the problems in this field have strong ties with human cognition and perception. This makes the human brain and sensory system the only truly appropriate evaluation platform for evaluating and fine-tuning a new visualization method or paradigm. However, getting humans to volunteer for these purposes has always been a significant obstacle, and thus this phase of the development process has traditionally formed a bottleneck, slowing down progress in visualization research. We propose to take advantage of the newly emerging field of Human Computation (HC) to overcome these challenges. HC promotes the idea that rather than considering humans as users of the computational system, they can be made part of a hybrid computational loop consisting of traditional computation resources and the human brain and sensory system. This approach is particularly successful in cases where part of the computational problem is considered intractable using known computer algorithms but is trivial to common sense human knowledge. In this paper, we focus on HC from the perspective of solving visualization problems and also outline a framework by which humans can be easily seduced to volunteer their HC resources. We introduce a purpose-driven game titled "Disguise" which serves as a prototypical example for how the evaluation of visualization algorithms can be mapped into a fun and addicting activity, allowing this task to be accomplished in an extensive yet cost effective way. Finally, we sketch out a framework that transcends from the pure evaluation of existing visualization methods to the design of a new one.

  3. Helicopter Visual Aid System

    NASA Technical Reports Server (NTRS)

    Baisley, R. L.

    1973-01-01

    The results of an evaluation of police helicopter effectiveness revealed a need for improved visual capability. A JPL program developed a method that would enhance visual observation capability for both day and night usage and demonstrated the feasibility of the adopted approach. This approach made use of remote pointable optics, a display screen, a slaved covert searchlight, and a coupled camera. The approach was proved feasible through field testing and by judgement against evaluation criteria.

  4. Validity and Interrater Reliability of the Visual Quarter-Waste Method for Assessing Food Waste in Middle School and High School Cafeteria Settings.

    PubMed

    Getts, Katherine M; Quinn, Emilee L; Johnson, Donna B; Otten, Jennifer J

    2017-11-01

    Measuring food waste (ie, plate waste) in school cafeterias is an important tool to evaluate the effectiveness of school nutrition policies and interventions aimed at increasing consumption of healthier meals. Visual assessment methods are frequently applied in plate waste studies because they are more convenient than weighing. The visual quarter-waste method has become a common tool in studies of school meal waste and consumption, but previous studies of its validity and reliability have used correlation coefficients, which measure association but not necessarily agreement. The aims of this study were to determine, using a statistic measuring interrater agreement, whether the visual quarter-waste method is valid and reliable for assessing food waste in a school cafeteria setting when compared with the gold standard of weighed plate waste. To evaluate validity, researchers used the visual quarter-waste method and weighed food waste from 748 trays at four middle schools and five high schools in one school district in Washington State during May 2014. To assess interrater reliability, researcher pairs independently assessed 59 of the same trays using the visual quarter-waste method. Both validity and reliability were assessed using a weighted κ coefficient. For validity, as compared with the measured weight, 45% of foods assessed using the visual quarter-waste method were in almost perfect agreement, 42% of foods were in substantial agreement, 10% were in moderate agreement, and 3% were in slight agreement. For interrater reliability between pairs of visual assessors, 46% of foods were in perfect agreement, 31% were in almost perfect agreement, 15% were in substantial agreement, and 8% were in moderate agreement. These results suggest that the visual quarter-waste method is a valid and reliable tool for measuring plate waste in school cafeteria settings. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  5. Comparing Visual and Statistical Analysis of Multiple Baseline Design Graphs.

    PubMed

    Wolfe, Katie; Dickenson, Tammiee S; Miller, Bridget; McGrath, Kathleen V

    2018-04-01

    A growing number of statistical analyses are being developed for single-case research. One important factor in evaluating these methods is the extent to which each corresponds to visual analysis. Few studies have compared statistical and visual analysis, and information about more recently developed statistics is scarce. Therefore, our purpose was to evaluate the agreement between visual analysis and four statistical analyses: improvement rate difference (IRD); Tau-U; Hedges, Pustejovsky, Shadish (HPS) effect size; and between-case standardized mean difference (BC-SMD). Results indicate that IRD and BC-SMD had the strongest overall agreement with visual analysis. Although Tau-U had strong agreement with visual analysis on raw values, it had poorer agreement when those values were dichotomized to represent the presence or absence of a functional relation. Overall, visual analysis appeared to be more conservative than statistical analysis, but further research is needed to evaluate the nature of these disagreements.

  6. A Customized Transportation Intervention for Persons with Visual Impairments

    ERIC Educational Resources Information Center

    Crudden, Adele; Antonelli, Karla; O'Mally, Jamie

    2017-01-01

    Introduction: Transportation can be an employment barrier for persons with disabilities, particularly those with visual impairments. A customized transportation intervention for people with visual impairments, based on concepts associated with customized employment, was devised, implemented, and evaluated. Methods: A pretest and posttest…

  7. A novel genome signature based on inter-nucleotide distances profiles for visualization of metagenomic data

    NASA Astrophysics Data System (ADS)

    Xie, Xian-Hua; Yu, Zu-Guo; Ma, Yuan-Lin; Han, Guo-Sheng; Anh, Vo

    2017-09-01

    There has been a growing interest in visualization of metagenomic data. The present study focuses on the visualization of metagenomic data using inter-nucleotide distances profile. We first convert the fragment sequences into inter-nucleotide distances profiles. Then we analyze these profiles by principal component analysis. Finally the principal components are used to obtain the 2-D scattered plot according to their source of species. We name our method as inter-nucleotide distances profiles (INP) method. Our method is evaluated on three benchmark data sets used in previous published papers. Our results demonstrate that the INP method is good, alternative and efficient for visualization of metagenomic data.

  8. Stress Associated with Transportation: A Survey of Persons with Visual Impairments

    ERIC Educational Resources Information Center

    Crudden, Adele; Cmar, Jennifer L.; McDonnall, Michele C.

    2017-01-01

    Introduction: This study evaluated transportation-related stress and factors predicting stress among persons with visual impairments. Methods: Participants with visual impairments completed electronic surveys rating their stress levels experienced when completing various walking and public transportation tasks. They also indicated activities they…

  9. Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.

    PubMed

    Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios

    2017-01-01

    To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.

  10. Visual impact assessment in British oil and gas developments

    Treesearch

    Dennis F. Gillespie; Brian D. Clark

    1979-01-01

    Development of oil and gas resource in the North Sea has led to the application of visual impact assessment techniques to onshore oil and gas developments in the United Kingdom. Formal visual impact assessment methods are needed to supplement landscape evaluations and site selection studies. Three major orientations of British visual impact assessments are: the...

  11. Visualization of medical data based on EHR standards.

    PubMed

    Kopanitsa, G; Hildebrand, C; Stausberg, J; Englmeier, K H

    2013-01-01

    To organize an efficient interaction between a doctor and an EHR the data has to be presented in the most convenient way. Medical data presentation methods and models must be flexible in order to cover the needs of the users with different backgrounds and requirements. Most visualization methods are doctor oriented, however, there are indications that the involvement of patients can optimize healthcare. The research aims at specifying the state of the art of medical data visualization. The paper analyzes a number of projects and defines requirements for a generic ISO 13606 based data visualization method. In order to do so it starts with a systematic search for studies on EHR user interfaces. In order to identify best practices visualization methods were evaluated according to the following criteria: limits of application, customizability, re-usability. The visualization methods were compared by using specified criteria. The review showed that the analyzed projects can contribute knowledge to the development of a generic visualization method. However, none of them proposed a model that meets all the necessary criteria for a re-usable standard based visualization method. The shortcomings were mostly related to the structure of current medical concept specifications. The analysis showed that medical data visualization methods use hardcoded GUI, which gives little flexibility. So medical data visualization has to turn from a hardcoded user interface to generic methods. This requires a great effort because current standards are not suitable for organizing the management of visualization data. This contradiction between a generic method and a flexible and user-friendly data layout has to be overcome.

  12. Vision and quality-of-life.

    PubMed Central

    Brown, G C

    1999-01-01

    OBJECTIVE: To determine the relationship of visual acuity loss to quality of life. DESIGN: Three hundred twenty-five patients with visual loss to a minimum of 20/40 or greater in at least 1 eye were interviewed in a standardized fashion using a modified VF-14, questionnaire. Utility values were also obtained using both the time trade-off and standard gamble methods of utility assessment. MAIN OUTCOME MEASURES: Best-corrected visual acuity was correlated with the visual function score on the modified VF-14 questionnaire, as well as with utility values obtained using both the time trade-off and standard gamble methods. RESULTS: Decreasing levels of vision in the eye with better acuity correlated directly with decreasing visual function scores on the modified VF-14 questionnaire, as did decreasing utility values using the time trade-off method of utility evaluation. The standard gamble method of utility evaluation was not as directly correlated with vision as the time trade-off method. Age, level of education, gender, race, length of time of visual loss, and the number of associated systemic comorbidities did not significantly affect the time trade-off utility values associated with visual loss in the better eye. The level of reduced vision in the better eye, rather than the specific disease process causing reduced vision, was related to mean utility values. The average person with 20/40 vision in the better seeing eye was willing to trade 2 of every 10 years of life in return for perfect vision (utility value of 0.8), while the average person with counting fingers vision in the better eye was willing to trade approximately 5 of every 10 remaining years of life (utility value of 0.52) in return for perfect vision. CONCLUSIONS: The time trade-off method of utility evaluation appears to be an effective method for assessing quality of life associated with visual loss. Time trade-off utility values decrease in direct conjunction with decreasing vision in the better-seeing eye. Unlike the modified VF-14 test and its counterparts, utility values allow the quality of life associated with visual loss to be more readily compared to the quality of life associated with other health (disease) states. This information can be employed for cost-effective analyses that objectively compare evidence-based medicine, patient-based preferences and sound econometric principles across all specialties in health care. PMID:10703139

  13. Innovations for Evaluation Research: Multiform Protocols, Visual Analog Scaling, and the Retrospective Pretest-Posttest Design.

    PubMed

    Chang, Rong; Little, Todd D

    2018-06-01

    In this article, we review three innovative methods: multiform protocols, visual analog scaling, and the retrospective pretest-posttest design that can be used in evaluation research. These three techniques have been proposed for decades, but unfortunately, they are still not utilized readily in evaluation research. Our goal is to familiarize researchers with these underutilized research techniques that could reduce personnel effort and costs for data collection while producing better inferences for a study. We begin by discussing their applications and special unique features. We then discuss each technique's strengths and limitations and offer practical tips on how to better implement these methods in evaluation research. We then showcase two recent empirical studies that implement these methods in real-world evaluation research applications.

  14. Interactive visualization of public health indicators to support policymaking: An exploratory study

    PubMed Central

    Zakkar, Moutasem; Sedig, Kamran

    2017-01-01

    Purpose The purpose of this study is to examine the use of interactive visualizations to represent data/information related to social determinants of health and public health indicators, and to investigate the benefits of such visualizations for health policymaking. Methods: The study developed a prototype for an online interactive visualization tool that represents the social determinants of health. The study participants explored and used the tool. The tool was evaluated using the informal user experience evaluation method. This method involves the prospective users of a tool to use and play with it and their feedback to be collected through interviews. Results: Using visualizations to represent and interact with health indicators has advantages over traditional representation techniques that do not allow users to interact with the information. Communicating healthcare indicators to policymakers is a complex task because of the complexity of the indicators, diversity of audiences, and different audience needs. This complexity can lead to information misinterpretation, which occurs when users of the health data ignore or do not know why, where, and how the data has been produced, or where and how it can be used. Conclusions: Public health policymaking is a complex process, and data is only one element among others needed in this complex process. Researchers and healthcare organizations should conduct a strategic evaluation to assess the usability of interactive visualizations and decision support tools before investing in these tools. Such evaluation should take into consideration the cost, ease of use, learnability, and efficiency of those tools, and the factors that influence policymaking. PMID:29026455

  15. Ranking of physiotherapeutic evaluation methods as outcome measures of stifle functionality in dogs.

    PubMed

    Hyytiäinen, Heli K; Mölsä, Sari H; Junnila, Jouni T; Laitinen-Vapaavuori, Outi M; Hielm-Björkman, Anna K

    2013-04-08

    Various physiotherapeutic evaluation methods are used to assess the functionality of dogs with stifle problems. Neither validity nor sensitivity of these methods has been investigated. This study aimed to determine the most valid and sensitive physiotherapeutic evaluation methods for assessing functional capacity in hind limbs of dogs with stifle problems and to serve as a basis for developing an indexed test for these dogs. A group of 43 dogs with unilateral surgically treated cranial cruciate ligament deficiency and osteoarthritic findings was used to test different physiotherapeutic evaluation methods. Twenty-one healthy dogs served as the control group and were used to determine normal variation in static weight bearing and range of motion.The protocol consisted of 14 different evaluation methods: visual evaluation of lameness, visual evaluation of diagonal movement, visual evaluation of functional active range of motion and difference in thrust of hind limbs via functional tests (sit-to-move and lie-to-move), movement in stairs, evaluation of hind limb muscle atrophy, manual evaluation of hind limb static weight bearing, quantitative measurement of static weight bearing of hind limbs with bathroom scales, and passive range of motion of hind limb stifle (flexion and extension) and tarsal (flexion and extension) joints using a universal goniometer. The results were compared with those from an orthopaedic examination, force plate analysis, radiographic evaluation, and a conclusive assessment. Congruity of the methods was assessed with a combination of three statistical approaches (Fisher's exact test and two differently calculated proportions of agreeing observations), and the components were ranked from best to worst. Sensitivities of all of the physiotherapeutic evaluation methods against each standard were calculated. Evaluation of asymmetry in a sitting and lying position, assessment of muscle atrophy, manual and measured static weight bearing, and measurement of stifle passive range of motion were the most valid and sensitive physiotherapeutic evaluation methods. Ranking of the various physiotherapeutic evaluation methods was accomplished. Several of these methods can be considered valid and sensitive when examining the functionality of dogs with stifle problems.

  16. Ranking of physiotherapeutic evaluation methods as outcome measures of stifle functionality in dogs

    PubMed Central

    2013-01-01

    Background Various physiotherapeutic evaluation methods are used to assess the functionality of dogs with stifle problems. Neither validity nor sensitivity of these methods has been investigated. This study aimed to determine the most valid and sensitive physiotherapeutic evaluation methods for assessing functional capacity in hind limbs of dogs with stifle problems and to serve as a basis for developing an indexed test for these dogs. A group of 43 dogs with unilateral surgically treated cranial cruciate ligament deficiency and osteoarthritic findings was used to test different physiotherapeutic evaluation methods. Twenty-one healthy dogs served as the control group and were used to determine normal variation in static weight bearing and range of motion. The protocol consisted of 14 different evaluation methods: visual evaluation of lameness, visual evaluation of diagonal movement, visual evaluation of functional active range of motion and difference in thrust of hind limbs via functional tests (sit-to-move and lie-to-move), movement in stairs, evaluation of hind limb muscle atrophy, manual evaluation of hind limb static weight bearing, quantitative measurement of static weight bearing of hind limbs with bathroom scales, and passive range of motion of hind limb stifle (flexion and extension) and tarsal (flexion and extension) joints using a universal goniometer. The results were compared with those from an orthopaedic examination, force plate analysis, radiographic evaluation, and a conclusive assessment. Congruity of the methods was assessed with a combination of three statistical approaches (Fisher’s exact test and two differently calculated proportions of agreeing observations), and the components were ranked from best to worst. Sensitivities of all of the physiotherapeutic evaluation methods against each standard were calculated. Results Evaluation of asymmetry in a sitting and lying position, assessment of muscle atrophy, manual and measured static weight bearing, and measurement of stifle passive range of motion were the most valid and sensitive physiotherapeutic evaluation methods. Conclusions Ranking of the various physiotherapeutic evaluation methods was accomplished. Several of these methods can be considered valid and sensitive when examining the functionality of dogs with stifle problems. PMID:23566355

  17. Criterion validity of the visual estimation method for determining patients' meal intake in a community hospital.

    PubMed

    Kawasaki, Yui; Sakai, Masashi; Nishimura, Kazuhiro; Fujiwara, Keiko; Fujisaki, Kahori; Shimpo, Misa; Akamatsu, Rie

    2016-12-01

    The accuracy of the visual estimation method is unknown, even though it is commonly used in hospitals to measure the dietary intake of patients. We aimed to compare the difference in the validity of visual estimation according to the raters' job categories and tray divisions, and to demonstrate associations between meal characteristics and validity of visual estimation in a usual clinical setting in a community hospital. We collected patients' dietary intake data in usual clinical settings for each tray in 3 ways: visual estimation by nursing assistants, visual estimation by dietitians, and weighing by researchers (reference method). Dietitians estimated the dietary intake using 2 divisions, namely, whole tray and food items. Then we compared the weights and visual estimation data to evaluate the validity of the visual estimation method. Mean nutrient consumption of target trays was significantly different when using the visual estimation of target trays than when using the weighed method (visual estimation by nursing assistants [589 ± 168 kcal, 24.3 ± 7.0 g/tray, p < 0.01], dietitians' whole trays [561 ± 171 kcal, 23.0 ± 6.9 g/tray, p < 0.05], food items [562 ± 171 kcal/tray, p < 0.05], and dietitians' food items [23.4 ± 7.3 g/tray, p = 0.63]). Spearman's correlations for both methods were very high for energy (ρ = 0.91-0.98, p < 0.01) and protein intakes (ρ = 0.88-0.96, p < 0.01), respectively. The limits of agreement in the Bland-Altman plot for both dietary intake categories were -121 kcal to 147 kcal/tray and -6.4 g to 7.0 g/tray (nursing assistants, whole division), -122 kcal-106 kcal/tray and -6.7 g to 5.5 g/tray (dietitians, whole divisions), and -82 kcal to 66 kcal/tray and -4.3 g to 3.9 g/tray (dietitians, food items divisions). High intake rate of grains was significantly associated with decreased odds of a difference between two methods based on the nursing assistant's whole tray evaluation (odds ratio [OR]: 0.85; 95% confidence interval [CI]: 0.76-0.94) and the dietitians' whole tray (OR: 0.80; 95% CI: 0.72-0.89) and food items evaluations (OR: 0.64; 95% CI: 0.56-0.73), respectively. In addition, minced meals were also associated with a difference between two methods, for the nursing assistants' whole tray (OR: 3.53; 95% CI: 1.66-7.51) and dietitians' food items (OR: 2.92; 95% CI: 1.37-6.22). Visual estimation by nursing assistants and dietitians correlated highly with the weighing method although the limits of agreement were wide. Nursing assistants and dietitians should pay attention to low consumption and modified texture meals when evaluating dietary intake using the visual estimation method. Copyright © 2016. Published by Elsevier Ltd.

  18. Strategies for Characterizing the Sensory Environment: Objective and Subjective Evaluation Methods using the VisiSonic Real Space 64/5 Audio-Visual Panoramic Camera

    DTIC Science & Technology

    2017-11-01

    ARL-TR-8205 ● NOV 2017 US Army Research Laboratory Strategies for Characterizing the Sensory Environment: Objective and...Subjective Evaluation Methods using the VisiSonic Real Space 64/5 Audio-Visual Panoramic Camera By Joseph McArdle, Ashley Foots, Chris Stachowiak, and...return it to the originator. ARL-TR-8205 ● NOV 2017 US Army Research Laboratory Strategies for Characterizing the Sensory

  19. Stereoscopic visual fatigue assessment and modeling

    NASA Astrophysics Data System (ADS)

    Wang, Danli; Wang, Tingting; Gong, Yue

    2014-03-01

    Evaluation of stereoscopic visual fatigue is one of the focuses in the user experience research. It is measured in either subjective or objective methods. Objective measures are more preferred for their capability to quantify the degree of human visual fatigue without being affected by individual variation. However, little research has been conducted on the integration of objective indicators, or the sensibility of each objective indicator in reflecting subjective fatigue. The paper proposes a simply effective method to evaluate visual fatigue more objectively. The stereoscopic viewing process is divided into series of sessions, after each of which viewers rate their visual fatigue with subjective scores (SS) according to a five-grading scale, followed by tests of the punctum maximum accommodation (PMA) and visual reaction time (VRT). Throughout the entire viewing process, their eye movements are recorded by an infrared camera. The pupil size (PS) and percentage of eyelid closure over the pupil over time (PERCLOS) are extracted from the videos processed by the algorithm. Based on the method, an experiment with 14 subjects was conducted to assess visual fatigue induced by 3D images on polarized 3D display. The experiment consisted of 10 sessions (5min per session), each containing the same 75 images displayed randomly. The results show that PMA, VRT and PERCLOS are the most efficient indicators of subjective visual fatigue and finally a predictive model is derived from the stepwise multiple regressions.

  20. The Effect of Visualized Instruction and Varied Rehearsal and Evaluation Strategies (Verbal and Visual) in Facilitating Students' Long-Term Retention on Tests Measuring Different Instructional Objectives.

    ERIC Educational Resources Information Center

    Dwyer, Francis M.

    1985-01-01

    This study investigated effects of rehearsal strategies and immediate test formats on delayed retention and effectiveness of visualization on material acquisition and retrieval. Findings indicate different rehearsal methods have different effects in facilitating delayed retention. Information acquisition is facilitated by visualization, although…

  1. Laser Pencil Beam Based Techniques for Visualization and Analysis of Interfaces Between Media

    NASA Technical Reports Server (NTRS)

    Adamovsky, Grigory; Giles, Sammie, Jr.

    1998-01-01

    Traditional optical methods that include interferometry, Schlieren, and shadowgraphy have been used successfully for visualization and evaluation of various media. Aerodynamics and hydrodynamics are major fields where these methods have been applied. However, these methods have such major drawbacks as a relatively low power density and suppression of the secondary order phenomena. A novel method introduced at NASA Lewis Research Center minimizes disadvantages of the 'classical' methods. The method involves a narrow pencil-like beam that penetrates a medium of interest. The paper describes the laser pencil beam flow visualization methods in detail. Various system configurations are presented. The paper also discusses interfaces between media in general terms and provides examples of interfaces.

  2. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    PubMed

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  3. Route visualization using detail lenses.

    PubMed

    Karnick, Pushpak; Cline, David; Jeschke, Stefan; Razdan, Anshuman; Wonka, Peter

    2010-01-01

    We present a method designed to address some limitations of typical route map displays of driving directions. The main goal of our system is to generate a printable version of a route map that shows the overview and detail views of the route within a single, consistent visual frame. Our proposed visualization provides a more intuitive spatial context than a simple list of turns. We present a novel multifocus technique to achieve this goal, where the foci are defined by points of interest (POI) along the route. A detail lens that encapsulates the POI at a finer geospatial scale is created for each focus. The lenses are laid out on the map to avoid occlusion with the route and each other, and to optimally utilize the free space around the route. We define a set of layout metrics to evaluate the quality of a lens layout for a given route map visualization. We compare standard lens layout methods to our proposed method and demonstrate the effectiveness of our method in generating aesthetically pleasing layouts. Finally, we perform a user study to evaluate the effectiveness of our layout choices.

  4. Familiarity Vs Trust: A Comparative Study of Domain Scientists' Trust in Visual Analytics and Conventional Analysis Methods.

    PubMed

    Dasgupta, Aritra; Lee, Joon-Yong; Wilson, Ryan; Lafrance, Robert A; Cramer, Nick; Cook, Kristin; Payne, Samuel

    2017-01-01

    Combining interactive visualization with automated analytical methods like statistics and data mining facilitates data-driven discovery. These visual analytic methods are beginning to be instantiated within mixed-initiative systems, where humans and machines collaboratively influence evidence-gathering and decision-making. But an open research question is that, when domain experts analyze their data, can they completely trust the outputs and operations on the machine-side? Visualization potentially leads to a transparent analysis process, but do domain experts always trust what they see? To address these questions, we present results from the design and evaluation of a mixed-initiative, visual analytics system for biologists, focusing on analyzing the relationships between familiarity of an analysis medium and domain experts' trust. We propose a trust-augmented design of the visual analytics system, that explicitly takes into account domain-specific tasks, conventions, and preferences. For evaluating the system, we present the results of a controlled user study with 34 biologists where we compare the variation of the level of trust across conventional and visual analytic mediums and explore the influence of familiarity and task complexity on trust. We find that despite being unfamiliar with a visual analytic medium, scientists seem to have an average level of trust that is comparable with the same in conventional analysis medium. In fact, for complex sense-making tasks, we find that the visual analytic system is able to inspire greater trust than other mediums. We summarize the implications of our findings with directions for future research on trustworthiness of visual analytic systems.

  5. The visual stress model—A psycho-physiological method for the evaluation of operational reliability of pilots and cosmonauts

    NASA Astrophysics Data System (ADS)

    Kammel, H.; Haase, H.

    An experimental psycho-physiological method is presented for the evaluation of visual-cognitive performance preconditions and operational reliability of pilots and cosmonauts. As visual-cognitive stress are used tachistoscopically presented instrument symbols under conditions of individual speed of work and time pressure. The results of the compared extreme groups consisting of pilots with good and insufficient flight performance showed that the pilots with impairments to the quality of flight activity differ already before the test in their individual habitual characteristics and actual motivation, during the stress in their operational parameters, in the dimensions of their cardiorespiratory activation as well as in their efficiency and after the stress in their subjective experience of the stress. Conclusions are drawn for the evaluation of the aptitude of pilots and cosmonauts.

  6. Training Organizations in Use of a Modified Stream Visual Assessment Protocol

    ERIC Educational Resources Information Center

    Obropta, Christopher C.; Yergeau, Steven E.

    2011-01-01

    The Stream Visual Assessment Protocol (SVAP) was evaluated as a means to increase watershed surveys in New Jersey. Groups were trained in an SVAP modified for New Jersey streams. Participants in three training workshops were surveyed to determine the usefulness of SVAP as a cost-effective method to evaluate watershed health. Many respondents found…

  7. Holistic and Individualistic Evaluations of Digital Visual Art Portfolios: A Mixed Methods Study

    ERIC Educational Resources Information Center

    Cavill, William D., Jr.

    2017-01-01

    The high-stakes nature of portfolio evaluation makes it necessary to perform such assessments in the fairest and most equitable manner possible. Determining whether or not there is a difference between holistically and individualistically derived scores for digital visual art portfolios and how those differences can be explained was the focus of…

  8. Blue Whale Visual and Acoustic Encounter Rates in the Southern California Bight

    DTIC Science & Technology

    2007-07-01

    blue whale (Balaenoptera musculus) visual and acoustic encounter rates was quantitatively evaluated using hourly counts of detected whales during...surveys occurring in April, there were visual and acoustic detections of blue whales in all surveyed months and regions. Encounter rate is...difference between acoustic encounters of singing whales and visual encounters suggest seasonal variation in the ability of each method to detect blue

  9. A Quantitative Analysis of the Work Experiences of Adults with Visual Impairments in Nigeria

    ERIC Educational Resources Information Center

    Wolffe, Karen E.; Ajuwon, Paul M.; Kelly, Stacy M.

    2013-01-01

    Introduction: Worldwide, people with visual impairments often struggle to gain employment. This study attempts to closely evaluate the work experiences of employed individuals with visual impairments living in one of the world's most populous developing nations, Nigeria. Methods: The researchers developed a questionnaire that assessed personal and…

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fangyan; Zhang, Song; Chung Wong, Pak

    Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, themore » size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.« less

  11. Visualization of risk of radiogenic second cancer in the organs and tissues of the human body.

    PubMed

    Zhang, Rui; Mirkovic, Dragan; Newhauser, Wayne D

    2015-04-28

    Radiogenic second cancer is a common late effect in long term cancer survivors. Currently there are few methods or tools available to visually evaluate the spatial distribution of risks of radiogenic late effects in the human body. We developed a risk visualization method and demonstrated it for radiogenic second cancers in tissues and organs of one patient treated with photon volumetric modulated arc therapy and one patient treated with proton craniospinal irradiation. Treatment plans were generated using radiotherapy treatment planning systems (TPS) and dose information was obtained from TPS. Linear non-threshold risk coefficients for organs at risk of second cancer incidence were taken from the Biological Effects of Ionization Radiation VII report. Alternative risk models including linear exponential model and linear plateau model were also examined. The predicted absolute lifetime risk distributions were visualized together with images of the patient anatomy. The risk distributions of second cancer for the two patients were visually presented. The risk distributions varied with tissue, dose, dose-risk model used, and the risk distribution could be similar to or very different from the dose distribution. Our method provides a convenient way to directly visualize and evaluate the risks of radiogenic second cancer in organs and tissues of the human body. In the future, visual assessment of risk distribution could be an influential determinant for treatment plan scoring.

  12. A rapid method to visualize von willebrand factor multimers by using agarose gel electrophoresis, immunolocalization and luminographic detection.

    PubMed

    Krizek, D R; Rick, M E

    2000-03-15

    A highly sensitive and rapid clinical method for the visualization of the multimeric structure of von Willebrand Factor in plasma and platelets is described. The method utilizes submerged horizontal agarose gel electrophoresis, followed by transfer of the von Willebrand Factor onto a polyvinylidine fluoride membrane, and immunolocalization and luminographic visualization of the von Willebrand Factor multimeric pattern. This method distinguishes type 1 from types 2A and 2B von Willebrand disease, allowing timely evaluation and classification of von Willebrand Factor in patient plasma. It also allows visualization of the unusually high molecular weight multimers present in platelets. There are several major advantages to this method including rapid processing, simplicity of gel preparation, high sensitivity to low concentrations of von Willebrand Factor, and elimination of radioactivity.

  13. Estimation of bio-signal based on human motion for integrated visualization of daily-life.

    PubMed

    Umetani, Tomohiro; Matsukawa, Tsuyoshi; Yokoyama, Kiyoko

    2007-01-01

    This paper describes a method for the estimation of bio-signals based on human motion in daily life for an integrated visualization system. The recent advancement of computers and measurement technology has facilitated the integrated visualization of bio-signals and human motion data. It is desirable to obtain a method to understand the activities of muscles based on human motion data and evaluate the change in physiological parameters according to human motion for visualization applications. We suppose that human motion is generated by the activities of muscles reflected from the brain to bio-signals such as electromyograms. This paper introduces a method for the estimation of bio-signals based on neural networks. This method can estimate the other physiological parameters based on the same procedure. The experimental results show the feasibility of the proposed method.

  14. Comparison of visual survey and seining methods for estimating abundance of an endangered, benthic stream fish

    USGS Publications Warehouse

    Jordan, F.; Jelks, H.L.; Bortone, S.A.; Dorazio, R.M.

    2008-01-01

    We compared visual survey and seining methods for estimating abundance of endangered Okaloosa darters, Etheostoma okaloosae, in 12 replicate stream reaches during August 2001. For each 20-m stream reach, two divers systematically located and marked the position of darters and then a second crew of three to five people came through with a small-mesh seine and exhaustively sampled the same area. Visual surveys required little extra time to complete. Visual counts (24.2 ?? 12.0; mean ?? one SD) considerably exceeded seine captures (7.4 ?? 4.8), and counts from the two methods were uncorrelated. Visual surveys, but not seines, detected the presence of Okaloosa darters at one site with low population densities. In 2003, we performed a depletion removal study in 10 replicate stream reaches to assess the accuracy of the visual survey method. Visual surveys detected 59% of Okaloosa darters present, and visual counts and removal estimates were positively correlated. Taken together, our comparisons indicate that visual surveys more accurately and precisely estimate abundance of Okaloosa darters than seining and more reliably detect presence at low population densities. We recommend evaluation of visual survey methods when designing programs to monitor abundance of benthic fishes in clear streams, especially for threatened and endangered species that may be sensitive to handling and habitat disturbance. ?? 2007 Springer Science+Business Media, Inc.

  15. Visual analytics in medical education: impacting analytical reasoning and decision making for quality improvement.

    PubMed

    Vaitsis, Christos; Nilsson, Gunnar; Zary, Nabil

    2015-01-01

    The medical curriculum is the main tool representing the entire undergraduate medical education. Due to its complexity and multilayered structure it is of limited use to teachers in medical education for quality improvement purposes. In this study we evaluated three visualizations of curriculum data from a pilot course, using teachers from an undergraduate medical program and applying visual analytics methods. We found that visual analytics can be used to positively impacting analytical reasoning and decision making in medical education through the realization of variables capable to enhance human perception and cognition on complex curriculum data. The positive results derived from our evaluation of a medical curriculum and in a small scale, signify the need to expand this method to an entire medical curriculum. As our approach sustains low levels of complexity it opens a new promising direction in medical education informatics research.

  16. FE-ANN based modeling of 3D Simple Reinforced Concrete Girders for Objective Structural Health Evaluation : Tech Transfer Summary

    DOT National Transportation Integrated Search

    2017-06-01

    The objective of this study was to develop an objective, quantitative method for evaluating damage to bridge girders by using artificial neural networks (ANNs). This evaluation method, which is a supplement to visual inspection, requires only the res...

  17. Color-coded visualization of magnetic resonance imaging multiparametric maps

    NASA Astrophysics Data System (ADS)

    Kather, Jakob Nikolas; Weidner, Anja; Attenberger, Ulrike; Bukschat, Yannick; Weis, Cleo-Aron; Weis, Meike; Schad, Lothar R.; Zöllner, Frank Gerrit

    2017-01-01

    Multiparametric magnetic resonance imaging (mpMRI) data are emergingly used in the clinic e.g. for the diagnosis of prostate cancer. In contrast to conventional MR imaging data, multiparametric data typically include functional measurements such as diffusion and perfusion imaging sequences. Conventionally, these measurements are visualized with a one-dimensional color scale, allowing only for one-dimensional information to be encoded. Yet, human perception places visual information in a three-dimensional color space. In theory, each dimension of this space can be utilized to encode visual information. We addressed this issue and developed a new method for tri-variate color-coded visualization of mpMRI data sets. We showed the usefulness of our method in a preclinical and in a clinical setting: In imaging data of a rat model of acute kidney injury, the method yielded characteristic visual patterns. In a clinical data set of N = 13 prostate cancer mpMRI data, we assessed diagnostic performance in a blinded study with N = 5 observers. Compared to conventional radiological evaluation, color-coded visualization was comparable in terms of positive and negative predictive values. Thus, we showed that human observers can successfully make use of the novel method. This method can be broadly applied to visualize different types of multivariate MRI data.

  18. Development of a statistical method to help evaluating the transparency/opacity of decorative thin films

    NASA Astrophysics Data System (ADS)

    da Silva Oliveira, C. I.; Martinez-Martinez, D.; Al-Rjoub, A.; Rebouta, L.; Menezes, R.; Cunha, L.

    2018-04-01

    In this paper, we present a statistical method that allows evaluating the degree of a transparency of a thin film. To do so, the color coordinates are measured on different substrates, and the standard deviation is evaluated. In case of low values, the color depends on the film and not on the substrate, and intrinsic colors are obtained. In contrast, transparent films lead to high values of standard deviation, since the value of the color coordinates depends on the substrate. Between both extremes, colored films with a certain degree of transparency can be found. This method allows an objective and simple evaluation of the transparency of any film, improving the subjective visual inspection and avoiding the thickness problems related to optical spectroscopy evaluation. Zirconium oxynitride films deposited on three different substrates (Si, steel and glass) are used for testing the validity of this method, whose results have been validated with optical spectroscopy, and agree with the visual impression of the samples.

  19. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    PubMed Central

    Rowe, Fiona J.; Rowlands, Alison

    2014-01-01

    Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983

  20. Impacts of soil moisture content on visual soil evaluation

    NASA Astrophysics Data System (ADS)

    Emmet-Booth, Jeremy; Forristal, Dermot; Fenton, Owen; Bondi, Giulia; Creamer, Rachel; Holden, Nick

    2017-04-01

    Visual Soil Examination and Evaluation (VSE) techniques offer tools for soil quality assessment. They involve the visual and tactile assessment of soil properties such as aggregate size and shape, porosity, redox morphology, soil colour and smell. An increasing body of research has demonstrated the reliability and utility of VSE techniques. However a number of limitations have been identified, including the potential impact of soil moisture variation during sampling. As part of a national survey of grassland soil quality in Ireland, an evaluation of the impact of soil moisture on two widely used VSE techniques was conducted. The techniques were Visual Evaluation of Soil Structure (VESS) (Guimarães et al., 2011) and Visual Soil Assessment (VSA) (Shepherd, 2009). Both generate summarising numeric scores that indicate soil structural quality, though employ different scoring mechanisms. The former requires the assessment of properties concurrently and the latter separately. Both methods were deployed on 20 sites across Ireland representing a range of soils. Additional samples were taken for soil volumetric water (θ) determination at 5-10 and 10-20 cm depth. No significant correlation was observed between θ 5-10 cm and either VSE technique. However, VESS scores were significantly related to θ 10-20 cm (rs = 0.40, sig = 0.02) while VSA scores were not (rs = -0.33, sig = 0.06). VESS and VSA scores can be grouped into quality classifications (good, moderate and poor). No significant mean difference was observed between θ 5-10 cm or θ 10-20 cm according to quality classification by either method. It was concluded that VESS scores may be affected by soil moisture variation while VSA appear unaffected. The different scoring mechanisms, where the separate assessment and scoring of individual properties employed by VSA, may limit soil moisture effects. However, moisture content appears not to affect overall structural quality classification by either method. References Guimarães, R.M.C., Ball, B.C. & Tormena, C.A. 2011. Improvements in the visual evaluation of soil structure, Soil Use and Management, 27, 3: 395-403 Shepherd, G.T. 2009. Visual Soil Assessment. Field guide for pastoral grazing and cropping on flat to rolling country. 2nd edn. Horizons regional council, New Zealand.

  1. Quantitative comparison and reproducibility of pathologist scoring and digital image analysis of estrogen receptor β2 immunohistochemistry in prostate cancer.

    PubMed

    Rizzardi, Anthony E; Zhang, Xiaotun; Vogel, Rachel Isaksson; Kolb, Suzanne; Geybels, Milan S; Leung, Yuet-Kin; Henriksen, Jonathan C; Ho, Shuk-Mei; Kwak, Julianna; Stanford, Janet L; Schmechel, Stephen C

    2016-07-11

    Digital image analysis offers advantages over traditional pathologist visual scoring of immunohistochemistry, although few studies examining the correlation and reproducibility of these methods have been performed in prostate cancer. We evaluated the correlation between digital image analysis (continuous variable data) and pathologist visual scoring (quasi-continuous variable data), reproducibility of each method, and association of digital image analysis methods with outcomes using prostate cancer tissue microarrays (TMAs) stained for estrogen receptor-β2 (ERβ2). Prostate cancer TMAs were digitized and evaluated by pathologist visual scoring versus digital image analysis for ERβ2 staining within tumor epithelium. Two independent analysis runs were performed to evaluate reproducibility. Image analysis data were evaluated for associations with recurrence-free survival and disease specific survival following radical prostatectomy. We observed weak/moderate Spearman correlation between digital image analysis and pathologist visual scores of tumor nuclei (Analysis Run A: 0.42, Analysis Run B: 0.41), and moderate/strong correlation between digital image analysis and pathologist visual scores of tumor cytoplasm (Analysis Run A: 0.70, Analysis Run B: 0.69). For the reproducibility analysis, there was high Spearman correlation between pathologist visual scores generated for individual TMA spots across Analysis Runs A and B (Nuclei: 0.84, Cytoplasm: 0.83), and very high correlation between digital image analysis for individual TMA spots across Analysis Runs A and B (Nuclei: 0.99, Cytoplasm: 0.99). Further, ERβ2 staining was significantly associated with increased risk of prostate cancer-specific mortality (PCSM) when quantified by cytoplasmic digital image analysis (HR 2.16, 95 % CI 1.02-4.57, p = 0.045), nuclear image analysis (HR 2.67, 95 % CI 1.20-5.96, p = 0.016), and total malignant epithelial area analysis (HR 5.10, 95 % CI 1.70-15.34, p = 0.004). After adjusting for clinicopathologic factors, only total malignant epithelial area ERβ2 staining was significantly associated with PCSM (HR 4.08, 95 % CI 1.37-12.15, p = 0.012). Digital methods of immunohistochemical quantification are more reproducible than pathologist visual scoring in prostate cancer, suggesting that digital methods are preferable and especially warranted for studies involving large sample sizes.

  2. A Novel Locally Linear KNN Method With Applications to Visual Recognition.

    PubMed

    Liu, Qingfeng; Liu, Chengjun

    2017-09-01

    A locally linear K Nearest Neighbor (LLK) method is presented in this paper with applications to robust visual recognition. Specifically, the concept of an ideal representation is first presented, which improves upon the traditional sparse representation in many ways. The objective function based on a host of criteria for sparsity, locality, and reconstruction is then optimized to derive a novel representation, which is an approximation to the ideal representation. The novel representation is further processed by two classifiers, namely, an LLK-based classifier and a locally linear nearest mean-based classifier, for visual recognition. The proposed classifiers are shown to connect to the Bayes decision rule for minimum error. Additional new theoretical analysis is presented, such as the nonnegative constraint, the group regularization, and the computational efficiency of the proposed LLK method. New methods such as a shifted power transformation for improving reliability, a coefficients' truncating method for enhancing generalization, and an improved marginal Fisher analysis method for feature extraction are proposed to further improve visual recognition performance. Extensive experiments are implemented to evaluate the proposed LLK method for robust visual recognition. In particular, eight representative data sets are applied for assessing the performance of the LLK method for various visual recognition applications, such as action recognition, scene recognition, object recognition, and face recognition.

  3. Video quality assessment method motivated by human visual perception

    NASA Astrophysics Data System (ADS)

    He, Meiling; Jiang, Gangyi; Yu, Mei; Song, Yang; Peng, Zongju; Shao, Feng

    2016-11-01

    Research on video quality assessment (VQA) plays a crucial role in improving the efficiency of video coding and the performance of video processing. It is well acknowledged that the motion energy model generates motion energy responses in a middle temporal area by simulating the receptive field of neurons in V1 for the motion perception of the human visual system. Motivated by the biological evidence for the visual motion perception, a VQA method is proposed in this paper, which comprises the motion perception quality index and the spatial index. To be more specific, the motion energy model is applied to evaluate the temporal distortion severity of each frequency component generated from the difference of Gaussian filter bank, which produces the motion perception quality index, and the gradient similarity measure is used to evaluate the spatial distortion of the video sequence to get the spatial quality index. The experimental results of the LIVE, CSIQ, and IVP video databases demonstrate that the random forests regression technique trained by the generated quality indices is highly correspondent to human visual perception and has many significant improvements than comparable well-performing methods. The proposed method has higher consistency with subjective perception and higher generalization capability.

  4. Standardized Uptake Value Ratio-Independent Evaluation of Brain Amyloidosis.

    PubMed

    Chincarini, Andrea; Sensi, Francesco; Rei, Luca; Bossert, Irene; Morbelli, Silvia; Guerra, Ugo Paolo; Frisoni, Giovanni; Padovani, Alessandro; Nobili, Flavio

    2016-10-18

    The assessment of in vivo18F images targeting amyloid deposition is currently carried on by visual rating with an optional quantification based on standardized uptake value ratio (SUVr) measurements. We target the difficulties of image reading and possible shortcomings of the SUVr methods by validating a new semi-quantitative approach named ELBA. ELBA involves a minimal image preprocessing and does not rely on small, specific regions of interest (ROIs). It evaluates the whole brain and delivers a geometrical/intensity score to be used for ranking and dichotomic assessment. The method was applied to adniimages 18F-florbetapir images from the ADNI database. Five expert readers provided visual assessment in blind and open sessions. The longitudinal trend and the comparison to SUVr measurements were also evaluated. ELBA performed with area under the roc curve (AUC) = 0.997 versus the visual assessment. The score was significantly correlated to the SUVr values (r = 0.86, p < 10-4). The longitudinal analysis estimated a test/retest error of ≃2.3%. Cohort and longitudinal analysis suggests that the ELBA method accurately ranks the brain amyloid burden. The expert readers confirmed its relevance in aiding the visual assessment in a significant number (85) of difficult cases. Despite the good performance, poor and uneven image quality constitutes the major limitation.

  5. A Software Developer’s Guide to Informal Evaluation of Visual Analytics Environments Using VAST Challenge Information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Kristin A.; Scholtz, Jean; Whiting, Mark A.

    The VAST Challenge has been a popular venue for academic and industry participants for over ten years. Many participants comment that the majority of their time in preparing VAST Challenge entries is discovering elements in their software environments that need to be redesigned in order to solve the given task. Fortunately, there is no need to wait until the VAST Challenge is announced to test out software systems. The Visual Analytics Benchmark Repository contains all past VAST Challenge tasks, data, solutions and submissions. This paper details the various types of evaluations that may be conducted using the Repository information. Inmore » this paper we describe how developers can do informal evaluations of various aspects of their visual analytics environments using VAST Challenge information. Aspects that can be evaluated include the appropriateness of the software for various tasks, the various data types and formats that can be accommodated, the effectiveness and efficiency of the process supported by the software, and the intuitiveness of the visualizations and interactions. Researchers can compare their visualizations and interactions to those submitted to determine novelty. In addition, the paper provides pointers to various guidelines that software teams can use to evaluate the usability of their software. While these evaluations are not a replacement for formal evaluation methods, this information can be extremely useful during the development of visual analytics environments.« less

  6. [Comparison of digital and visual methods for Ki-67 assessment in invasive breast carcinomas].

    PubMed

    Kushnarev, V A; Artemyeva, E S; Kudaybergenova, A G

    2018-01-01

    to compare two methods for quantitative assessment of the proliferative activity index (PAI): a visual estimation method by several investigators and digital image analysis (DIA). The use of the Ki-67 index in the daily clinical practice of a Morbid Anatomy Department is associated with the problem of reproducibility of quantitative assessment of the Ki-67 PAI. Due to the development of digital imaging techniques in morphology, new methods for PAI evaluation using the DIA are proposed. The Ki-67 PAI data obtained during visual assessment and digital image analysis were compared in 104 cases of grades 2-3 breast carcinoma. The histological sections were scanned using a Panoramic III scanner (3D Histech, Hungary) and digital images were obtained. DIA was carried out using the software 3D Histech QuantCenter (3D Histech, Hungary), by marking 3-10 zones. Evaluation of the obtained sections was done independently by two investigators engaged in cancer pathology. The level of agreement between visual and digital methods did not differ significantly (p>0.001). The authors selected a gray area in the range of 10-35% IPA, where the Ki-67 index showed a weak relationship between the analyzed groups (ICC, 0.47). The Ki67 index below 10% and above 35% showed a sufficient reproducibility in the same laboratory. The authors consider that the scanned digital form of a histological section, which can be evaluated using automated software analysis modules, is an independent and objective method to assess proliferative activity for Ki-67 index validation.

  7. An overview of 3D software visualization.

    PubMed

    Teyseyre, Alfredo R; Campo, Marcelo R

    2009-01-01

    Software visualization studies techniques and methods for graphically representing different aspects of software. Its main goal is to enhance, simplify and clarify the mental representation a software engineer has of a computer system. During many years, visualization in 2D space has been actively studied, but in the last decade, researchers have begun to explore new 3D representations for visualizing software. In this article, we present an overview of current research in the area, describing several major aspects like: visual representations, interaction issues, evaluation methods and development tools. We also perform a survey of some representative tools to support different tasks, i.e., software maintenance and comprehension, requirements validation and algorithm animation for educational purposes, among others. Finally, we conclude identifying future research directions.

  8. The Elicitation Interview Technique: Capturing People's Experiences of Data Representations.

    PubMed

    Hogan, Trevor; Hinrichs, Uta; Hornecker, Eva

    2016-12-01

    Information visualization has become a popular tool to facilitate sense-making, discovery and communication in a large range of professional and casual contexts. However, evaluating visualizations is still a challenge. In particular, we lack techniques to help understand how visualizations are experienced by people. In this paper we discuss the potential of the Elicitation Interview technique to be applied in the context of visualization. The Elicitation Interview is a method for gathering detailed and precise accounts of human experience. We argue that it can be applied to help understand how people experience and interpret visualizations as part of exploration and data analysis processes. We describe the key characteristics of this interview technique and present a study we conducted to exemplify how it can be applied to evaluate data representations. Our study illustrates the types of insights this technique can bring to the fore, for example, evidence for deep interpretation of visual representations and the formation of interpretations and stories beyond the represented data. We discuss general visualization evaluation scenarios where the Elicitation Interview technique may be beneficial and specify what needs to be considered when applying this technique in a visualization context specifically.

  9. Fused methods for visual saliency estimation

    NASA Astrophysics Data System (ADS)

    Danko, Amanda S.; Lyu, Siwei

    2015-02-01

    In this work, we present a new model of visual saliency by combing results from existing methods, improving upon their performance and accuracy. By fusing pre-attentive and context-aware methods, we highlight the abilities of state-of-the-art models while compensating for their deficiencies. We put this theory to the test in a series of experiments, comparatively evaluating the visual saliency maps and employing them for content-based image retrieval and thumbnail generation. We find that on average our model yields definitive improvements upon recall and f-measure metrics with comparable precisions. In addition, we find that all image searches using our fused method return more correct images and additionally rank them higher than the searches using the original methods alone.

  10. An Evaluation of Wellness Assessment Visualizations for Older Adults

    PubMed Central

    Reeder, Blaine; Yoo, Daisy; Aziz, Rafae; Thompson, Hilaire J.; Demiris, George

    2015-01-01

    Abstract Background Smart home technologies provide a valuable resource to unobtrusively monitor health and wellness within an older adult population. However, the breadth and density of data available along with aging associated decreases in working memory, prospective memory, spatial cognition, and processing speed can make it challenging to comprehend for older adults. We developed visualizations of smart home health data integrated into a framework of wellness. We evaluated the visualizations through focus groups with older adults and identified recommendations to guide the future development of visualizations. Materials and Methods We conducted four focus groups with older adult participants (n=31) at an independent retirement community. Participants were presented with three different visualizations from a wellness pilot study. A qualitative descriptive analysis was conducted to identify thematic content. Results We identified three themes related to processing and application of visualizations: (1) values of visualizations for wellness assessment, (2) cognitive processing approaches to visualizations, and (3) integration of health data for visualization. In addition, the focus groups highlighted key design considerations of visualizations important towards supporting decision-making and evaluation assessments within integrated health displays. Conclusions Participants found inherent value in having visualizations available to proactively engage with their healthcare provider. Integrating the visualizations into a wellness framework helped reduce the complexity of raw smart home data. There has been limited work on health visualizations from a consumer perspective, in particular for an older adult population. Creating appropriately designed visualizations is valuable towards promoting consumer involvement within the shared decision-making process of care. PMID:25401414

  11. Method and Apparatus for Evaluating the Visual Quality of Processed Digital Video Sequences

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B. (Inventor)

    2002-01-01

    A Digital Video Quality (DVQ) apparatus and method that incorporate a model of human visual sensitivity to predict the visibility of artifacts. The DVQ method and apparatus are used for the evaluation of the visual quality of processed digital video sequences and for adaptively controlling the bit rate of the processed digital video sequences without compromising the visual quality. The DVQ apparatus minimizes the required amount of memory and computation. The input to the DVQ apparatus is a pair of color image sequences: an original (R) non-compressed sequence, and a processed (T) sequence. Both sequences (R) and (T) are sampled, cropped, and subjected to color transformations. The sequences are then subjected to blocking and discrete cosine transformation, and the results are transformed to local contrast. The next step is a time filtering operation which implements the human sensitivity to different time frequencies. The results are converted to threshold units by dividing each discrete cosine transform coefficient by its respective visual threshold. At the next stage the two sequences are subtracted to produce an error sequence. The error sequence is subjected to a contrast masking operation, which also depends upon the reference sequence (R). The masked errors can be pooled in various ways to illustrate the perceptual error over various dimensions, and the pooled error can be converted to a visual quality measure.

  12. Toward a perceptual video-quality metric

    NASA Astrophysics Data System (ADS)

    Watson, Andrew B.

    1998-07-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating the visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics, and the economic need to reduce bit-rate to the lowest level that yields acceptable quality. In previous work, we have developed visual quality metrics for evaluating, controlling,a nd optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. Here I describe a new video quality metric that is an extension of these still image metrics into the time domain. Like the still image metrics, it is based on the Discrete Cosine Transform. An effort has been made to minimize the amount of memory and computation required by the metric, in order that might be applied in the widest range of applications. To calibrate the basic sensitivity of this metric to spatial and temporal signals we have made measurements of visual thresholds for temporally varying samples of DCT quantization noise.

  13. Visualization of Data Regarding Infections Using Eye Tracking Techniques.

    PubMed

    Yoon, Sunmoo; Cohen, Bevin; Cato, Kenrick D; Liu, Jianfang; Larson, Elaine L

    2016-05-01

    To evaluate ease of use and usefulness for nurses of visualizations of infectious disease transmission in a hospital. An observational study was used to evaluate perceptions of several visualizations of data extracted from electronic health records designed using a participatory approach. Twelve nurses in the master's program in an urban research-intensive nursing school participated in May 2015. A convergent parallel mixed method was used to evaluate nurses' perceptions on ease of use and usefulness of five visualization conveying trends in hospital infection transmission applying think-aloud, interview, and eye-tracking techniques. Subjective data from the interview and think-aloud techniques indicated that participants preferred the traditional line graphs in simple data representation due to their familiarity, clarity, and easiness to read. An objective quantitative measure of eye movement analysis (444,421 gaze events) identified a high degree of participants' attention span in infographics in all three scenarios. All participants responded with the correct answer within 1 min in comprehensive tests. A user-centric approach was effective in developing and evaluating visualizations for hospital infection transmission. For the visualizations designed by the users, the participants were easily able to comprehend the infection visualizations on both line graphs and infographics for simple visualization. The findings from the objective comprehension test and eye movement and subjective attitudes support the feasibility of integrating user-centric visualization designs into electronic health records, which may inspire clinicians to be mindful of hospital infection transmission. Future studies are needed to investigate visualizations and motivation, and the effectiveness of visualization on infection rate. This study designed visualization images using clinical data from electronic health records applying a user-centric approach. The design insights can be applied for visualizing patient data in electronic health records. © 2016 Sigma Theta Tau International.

  14. Diversification of visual media retrieval results using saliency detection

    NASA Astrophysics Data System (ADS)

    Muratov, Oleg; Boato, Giulia; De Natale, Franesco G. B.

    2013-03-01

    Diversification of retrieval results allows for better and faster search. Recently there has been proposed different methods for diversification of image retrieval results mainly utilizing text information and techniques imported from natural language processing domain. However, images contain visual information that is impossible to describe in text and the use of visual features is inevitable. Visual saliency is information about the main object of an image implicitly included by humans while creating visual content. For this reason it is naturally to exploit this information for the task of diversification of the content. In this work we study whether visual saliency can be used for the task of diversification and propose a method for re-ranking image retrieval results using saliency. The evaluation has shown that the use of saliency information results in higher diversity of retrieval results.

  15. Objective Evaluation of Visual Fatigue Using Binocular Fusion Maintenance

    PubMed Central

    Hirota, Masakazu; Morimoto, Takeshi; Kanda, Hiroyuki; Endo, Takao; Miyoshi, Tomomitsu; Miyagawa, Suguru; Hirohara, Yoko; Yamaguchi, Tatsuo; Saika, Makoto

    2018-01-01

    Purpose In this study, we investigated whether an individual's visual fatigue can be evaluated objectively and quantitatively from their ability to maintain binocular fusion. Methods Binocular fusion maintenance (BFM) was measured using a custom-made binocular open-view Shack–Hartmann wavefront aberrometer equipped with liquid crystal shutters, wherein eye movements and wavefront aberrations were measured simultaneously. Transmittance in the liquid crystal shutter in front of the subject's nondominant eye was reduced linearly, and BFM was determined from the transmittance at the point when binocular fusion was broken and vergence eye movement was induced. In total, 40 healthy subjects underwent the BFM test and completed a questionnaire regarding subjective symptoms before and after a visual task lasting 30 minutes. Results BFM was significantly reduced after the visual task (P < 0.001) and was negatively correlated with the total subjective eye symptom score (adjusted R2 = 0.752, P < 0.001). Furthermore, the diagnostic accuracy for visual fatigue was significantly higher in BFM than in the conventional test results (aggregated fusional vergence range, near point of convergence, and the high-frequency component of accommodative microfluctuations; P = 0.007). Conclusions These results suggest that BFM can be used as an indicator for evaluating visual fatigue. Translational Relevance BFM can be used to evaluate the visual fatigue caused by the new visual devices, such as head-mount display, objectively. PMID:29600117

  16. Visual evaluation of color stability after accelerated aging of pigmented and nonpigmented silicones to be used in facial prostheses.

    PubMed

    Mancuso, Daniela Nardi; Goiato, Marcelo Coelho; Dekon, Stefan Fiuza de Carvalho; Gennari-Filho, Humberto

    2009-01-01

    The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.

  17. The adenosine triphosphate method as a quality control tool to assess 'cleanliness' of frequently touched hospital surfaces.

    PubMed

    Knape, L; Hambraeus, A; Lytsy, B

    2015-10-01

    The adenosine triphosphate (ATP) method is widely accepted as a quality control method to complement visual assessment, in the specifications of requirements, when purchasing cleaning contractors in Swedish hospitals. To examine whether the amount of biological load, as measured by ATP on frequently touched near-patient surfaces, had been reduced after an intervention; to evaluate the correlation between visual assessment and ATP levels on the same surfaces; to identify aspects of the performance of the ATP method as a tool in evaluating hospital cleanliness. A prospective intervention study in three phases was carried out in a medical ward and an intensive care unit (ICU) at a regional hospital in mid-Sweden between 2012 and 2013. Existing cleaning procedures were defined and baseline tests were sampled by visual inspection and ATP measurements of ten frequently touched surfaces in patients' rooms before and after intervention. The intervention consisted of educating nursing staff about the importance of hospital cleaning and direct feedback of ATP levels before and after cleaning. The mixed model showed a significant decrease in ATP levels after the intervention (P < 0.001). Relative light unit values were lower in the ICU. Cleanliness as judged by visual assessments improved. In the logistic regression analysis, there was a significant association between visual assessments and ATP levels. Direct feedback of ATP levels, together with education and introduction of written cleaning protocols, were effective tools to improve cleanliness. Visual assessment correlated with the level of ATP but the correlation was not absolute. The ATP method could serve as an educational tool for staff, but is not enough to assess hospital cleanliness in general as only a limited part of a large area is covered. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse.

    PubMed

    Furuta, Akihiro; Isoda, Hiroyoshi; Ohno, Tsuyoshi; Ono, Ayako; Yamashita, Rikiya; Arizono, Shigeki; Kido, Aki; Sakashita, Naotaka; Togashi, Kaori

    2018-01-01

    To selectively visualize the left gastric vein (LGV) with hepatopetal flow information by non-contrast-enhanced magnetic resonance angiography under a hypothesis that change in the LGV flow direction can predict the development of esophageal varices; and to optimize the acquisition protocol in healthy subjects. Respiratory-gated three-dimensional balanced steady-state free-precession scans were conducted on 31 healthy subjects using two methods (A and B) for visualizing the LGV with hepatopetal flow. In method A, two time-spatial labeling inversion pulses (Time-SLIP) were placed on the whole abdomen and the area from the gastric fornix to the upper body, excluding the LGV area. In method B, nonselective inversion recovery pulse was used and one Time-SLIP was placed on the esophagogastric junction. The detectability and consistency of LGV were evaluated using the two methods and ultrasonography (US). Left gastric veins by method A, B, and US were detected in 30 (97%), 24 (77%), and 23 (74%) subjects, respectively. LGV flow by US was hepatopetal in 22 subjects and stagnant in one subject. All hepatopetal LGVs by US coincided with the visualized vessels in both methods. One subject with non-visualized LGV in method A showed stagnant LGV by US. Hepatopetal LGV could be selectively visualized by method A in healthy subjects.

  19. Sealant retention is better assessed through colour photographs than through the replica and the visual examination methods.

    PubMed

    Hu, Xuan; Fan, Mingwan; Rong, Wensheng; Lo, Edward C M; Bronkhorst, Ewald; Frencken, Jo E

    2014-08-01

    The aim of this study was to test the hypothesis that the colour photograph method has a higher level of validity for assessing sealant retention than the visual clinical examination and replica methods. Sealed molars were assessed by two evaluators. The scores for the three methods were compared against consensus scores derived through assessing retention from scanning electron microscopy images (reference standard). The presence/absence (survival) of retained sealants on occlusal surfaces was determined according to the traditional and modified categorizations of retention. Sensitivity, specificity, and Youden-index scores were calculated. Sealant retention assessment scores for visual clinical examinations and for colour photographs were compared with those of the reference standard on 95 surfaces, and sealant retention assessment scores for replicas were compared with those of the reference standard on 33 surfaces. The highest mean Youden-index score for the presence/absence of sealant material was observed for the colour photograph method, followed by that for the replica method; the visual clinical examination method scored lowest. The mean Youden-index score for the survival of retained sealants was highest for the colour photograph method for both the traditional (0.882) and the modified (0.768) categories of sealant retention, whilst the visual clinical examination method had the lowest Youden-index score for these categories (0.745 and 0.063, respectively). The colour photograph method had a higher validity than the replica and the visual examination methods for assessing sealant retention. © 2014 Eur J Oral Sci.

  20. Visualization techniques for tongue analysis in traditional Chinese medicine

    NASA Astrophysics Data System (ADS)

    Pham, Binh L.; Cai, Yang

    2004-05-01

    Visual inspection of the tongue has been an important diagnostic method of Traditional Chinese Medicine (TCM). Clinic data have shown significant connections between various viscera cancers and abnormalities in the tongue and the tongue coating. Visual inspection of the tongue is simple and inexpensive, but the current practice in TCM is mainly experience-based and the quality of the visual inspection varies between individuals. The computerized inspection method provides quantitative models to evaluate color, texture and surface features on the tongue. In this paper, we investigate visualization techniques and processes to allow interactive data analysis with the aim to merge computerized measurements with human expert's diagnostic variables based on five-scale diagnostic conditions: Healthy (H), History Cancers (HC), History of Polyps (HP), Polyps (P) and Colon Cancer (C).

  1. Degradation of learned skills: Effectiveness of practice methods on visual approach and landing skill retention

    NASA Technical Reports Server (NTRS)

    Sitterley, T. E.; Zaitzeff, L. P.; Berge, W. A.

    1972-01-01

    Flight control and procedural task skill degradation, and the effectiveness of retraining methods were evaluated for a simulated space vehicle approach and landing under instrument and visual flight conditions. Fifteen experienced pilots were trained and then tested after 4 months either without the benefits of practice or with static rehearsal, dynamic rehearsal or with dynamic warmup practice. Performance on both the flight control and procedure tasks degraded significantly after 4 months. The rehearsal methods effectively countered procedure task skill degradation, while dynamic rehearsal or a combination of static rehearsal and dynamic warmup practice was required for the flight control tasks. The quality of the retraining methods appeared to be primarily dependent on the efficiency of visual cue reinforcement.

  2. Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan

    2015-01-01

    Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104

  3. Visualized Evaluation of Blood Flow to the Gastric Conduit and Complications in Esophageal Reconstruction.

    PubMed

    Noma, Kazuhiro; Shirakawa, Yasuhiro; Kanaya, Nobuhiko; Okada, Tsuyoshi; Maeda, Naoaki; Ninomiya, Takayuki; Tanabe, Shunsuke; Sakurama, Kazufumi; Fujiwara, Toshiyoshi

    2018-03-01

    Evaluation of the blood supply to gastric conduits is critically important to avoid complications after esophagectomy. We began visual evaluation of blood flow using indocyanine green (ICG) fluorescent imaging in July 2015, to reduce reconstructive complications. In this study, we aimed to statistically verify the efficacy of blood flow evaluation using our simplified ICG method. A total of 285 consecutive patients who underwent esophagectomy and gastric conduit reconstruction were reviewed and divided into 2 groups: before and after introduction of ICG evaluation. The entire cohort and 68 patient pairs after propensity score matching (PS-M) were evaluated for clinical outcomes and the effect of visualized evaluation on reducing the risk of complication. The leakage rate in the ICG group was significantly lower than in the non-ICG group for each severity grade, both in the entire cohort (285 subjects) and after PS-M; the rates of other major complications, including recurrent laryngeal nerve palsy and pneumonia, were not different. The duration of postoperative ICU stay was approximately 1 day shorter in the ICG group than in the non-ICG group in the entire cohort, and approximately 2 days shorter after PS-M. Visualized evaluation of blood flow with ICG methods significantly reduced the rate of anastomotic complications of all Clavien-Dindo (CD) grades. Odds ratios for ICG evaluation decreased with CD grade (0.3419 for CD ≥ 1; 0.241 for CD ≥ 2; and 0.2153 for CD ≥ 3). Objective evaluation of blood supply to the reconstructed conduit using ICG fluorescent imaging reduces the risk and degree of anastomotic complication. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Kris A.; Scholtz, Jean; Whiting, Mark A.

    The VAST Challenge has been a popular venue for academic and industry participants for over ten years. Many participants comment that the majority of their time in preparing VAST Challenge entries is discovering elements in their software environments that need to be redesigned in order to solve the given task. Fortunately, there is no need to wait until the VAST Challenge is announced to test out software systems. The Visual Analytics Benchmark Repository contains all past VAST Challenge tasks, data, solutions and submissions. This paper details the various types of evaluations that may be conducted using the Repository information. Inmore » this paper we describe how developers can do informal evaluations of various aspects of their visual analytics environments using VAST Challenge information. Aspects that can be evaluated include the appropriateness of the software for various tasks, the various data types and formats that can be accommodated, the effectiveness and efficiency of the process supported by the software, and the intuitiveness of the visualizations and interactions. Researchers can compare their visualizations and interactions to those submitted to determine novelty. In addition, the paper provides pointers to various guidelines that software teams can use to evaluate the usability of their software. While these evaluations are not a replacement for formal evaluation methods, this information can be extremely useful during the development of visual analytics environments.« less

  5. Comparing visual inspection, aerobic colony counts, and adenosine triphosphate bioluminescence assay for evaluating surface cleanliness at a medical center.

    PubMed

    Huang, Yu-Shan; Chen, Yee-Chun; Chen, Mei-Ling; Cheng, Aristine; Hung, I-Chen; Wang, Jann-Tay; Sheng, Wang-Huei; Chang, Shan-Chwen

    2015-08-01

    Environmental cleaning is essential in reducing microbial colonization and health care-associated infections in hospitals. However, there is no consensus for the standard method to assess hospital cleanliness, and comparisons of newer methodology, such as adenosine triphosphate bioluminescence assay, with the traditional methods are limited. A prospective study was conducted at a medical center between January 2013 and August 2013. In each selected room, 10-12 high-touch surfaces were sampled before and after terminal cleaning. The adequacy of cleaning was evaluated by visual inspection, aerobic colony counts (ACCs), and adenosine triphosphate (ATP) bioluminescence assay. Eighty-five environmental surfaces from 8 rooms were evaluated by all 3 methods. The overall inadequacy defined by visual inspection, ACC, and ATP level was 11.8%, 20.0%, and 50.6% before cleaning and 4.7%, 5.9%, 21.2% after cleaning, respectively. A correlation between the ACC and ATP was found (r = 0.285, P < .001) using log10 values. Using ACCs <2.5 colony forming units/cm(2) as the cutoff for cleanliness, the ATP assay had better sensitivity than visual inspection (63.6% vs 27.3%). The receiver operating characteristics of the ATP assay indicated that the optimal ATP cutoff value was estimated to be 5.57 relative light units/cm(2). ATP bioluminescence assay is a sensitive and rapid tool in evaluating the quality of terminal cleaning. We emphasize the value of using a quantitative method to monitor environmental cleaning at hospitals. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Effects of thickness and gain on the amplitude of airborne ultrasonics

    USDA-ARS?s Scientific Manuscript database

    Currently, hides and leather are visually inspected and ranked for quality, usable area, and sale price. However, visual inspection is not reliable for detecting defects, which are usually hidden inside the material. Development of a non-contact nondestructive method to accurately evaluate the qua...

  7. A Principled Way of Assessing Visualization Literacy.

    PubMed

    Boy, Jeremy; Rensink, Ronald A; Bertini, Enrico; Fekete, Jean-Daniel

    2014-12-01

    We describe a method for assessing the visualization literacy (VL) of a user. Assessing how well people understand visualizations has great value for research (e. g., to avoid confounds), for design (e. g., to best determine the capabilities of an audience), for teaching (e. g., to assess the level of new students), and for recruiting (e. g., to assess the level of interviewees). This paper proposes a method for assessing VL based on Item Response Theory. It describes the design and evaluation of two VL tests for line graphs, and presents the extension of the method to bar charts and scatterplots. Finally, it discusses the reimplementation of these tests for fast, effective, and scalable web-based use.

  8. Psychophysical Evaluation of Achromatic and Chromatic Vision of Workers Chronically Exposed to Organic Solvents

    PubMed Central

    Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima

    2012-01-01

    The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188

  9. Visually scoring hirsutism

    PubMed Central

    Yildiz, Bulent O.; Bolour, Sheila; Woods, Keslie; Moore, April; Azziz, Ricardo

    2010-01-01

    BACKGROUND Hirsutism is the presence of excess body or facial terminal (coarse) hair growth in females in a male-like pattern, affects 5–15% of women, and is an important sign of underlying androgen excess. Different methods are available for the assessment of hair growth in women. METHODS We conducted a literature search and analyzed the published studies that reported methods for the assessment of hair growth. We review the basic physiology of hair growth, the development of methods for visually quantifying hair growth, the comparison of these methods with objective measurements of hair growth, how hirsutism may be defined using a visual scoring method, the influence of race and ethnicity on hirsutism, and the impact of hirsutism in diagnosing androgen excess and polycystic ovary syndrome. RESULTS Objective methods for the assessment of hair growth including photographic evaluations and microscopic measurements are available but these techniques have limitations for clinical use, including a significant degree of complexity and a high cost. Alternatively, methods for visually scoring or quantifying the amount of terminal body and facial hair growth have been in use since the early 1920s; these methods are semi-quantitative at best and subject to significant inter-observer variability. The most common visual method of scoring the extent of body and facial terminal hair growth in use today is based on a modification of the method originally described by Ferriman and Gallwey in 1961 (i.e. the mFG method). CONCLUSION Overall, the mFG scoring method is a useful visual instrument for assessing excess terminal hair growth, and the presence of hirsutism, in women. PMID:19567450

  10. Qualitative interpretation of PET scans using a Likert scale to assess neck node response to radiotherapy in head and neck cancer.

    PubMed

    Sjövall, Johanna; Bitzén, Ulrika; Kjellén, Elisabeth; Nilsson, Per; Wahlberg, Peter; Brun, Eva

    2016-04-01

    The aim of this study was to determine whether PET scans after radiotherapy (RT), visually interpreted as equivocal regarding metabolic neck node response can be used to accurately categorize patients as responders or nonresponders using a Likert scale and/or maximum standardized uptake value (SUVmax). Other aims were to determine the performance of different methods for assessing post-RT PET scans (visual inspection, a Likert scale and SUVmax) and to establish whether any method is superior in predicting regional control (RC) and overall survival (OS). In 105 patients with neck node-positive head and neck cancer, the neck node response was evaluated by FDG PET/CT 6 weeks after RT. The scans were clinically assessed by visual inspection and, for the purposes of this analysis, re-evaluated using the Deauville criteria, a five-point Likert scale previously used in lymphoma studies. In addition, SUVmax was determined. All assessment methods were able to significantly predict RC but not OS. The methods were also able to significantly predict remission of tumour after completion of RT. Of the 105 PET scans, 19 were judged as equivocal on visual inspection. The Likert scale was preferable to SUVmax for grouping patients as responders or nonresponders. All methods (visual inspection, SUVmax and the Likert scale) identified responders and nonresponders and predicted RC. A Likert scale is a promising tool to reduce to a minimum the problem of PET scans judged as equivocal. Consensus regarding qualitative assessment would facilitate PET reporting in clinical practice.

  11. History and future of visual anthropology.

    PubMed

    Svilicić, Niksa

    2011-03-01

    Visual recording of communication processes between communities or individuals by means of filming of photographing is of significant importance in anthropology, as it documents on site the specific features of various social communities in their encounter with the researcher. In terms of film industry, it is a sort of ethno-documentary pursuing originality and objectivity in recording the given subject, thus fulfilling the research mission. However, the potential of visual anthropology significantly exceeds the mere audiovisual recording of ethnologic realities. Modern methods of analysing and evaluating the role of visual anthropology suggest that it is a technical research service aimed at documenting the status quo. If the direction of proactive approach were taken, then the term ,visual anthropology' could be changed to ,anthropology of the visual,. This apparently cosmetic change of name is actually significantly more accurate, suggesting the denoted proactive swift in perceiving visual anthropology, where visual methods are employed to ,provoke< the reaction of an individual or of the community. In this way the "anthropology of the visual, is promoted to a new scientific sub-anthropological discipline.

  12. Parts-based stereoscopic image assessment by learning binocular manifold color visual properties

    NASA Astrophysics Data System (ADS)

    Xu, Haiyong; Yu, Mei; Luo, Ting; Zhang, Yun; Jiang, Gangyi

    2016-11-01

    Existing stereoscopic image quality assessment (SIQA) methods are mostly based on the luminance information, in which color information is not sufficiently considered. Actually, color is part of the important factors that affect human visual perception, and nonnegative matrix factorization (NMF) and manifold learning are in line with human visual perception. We propose an SIQA method based on learning binocular manifold color visual properties. To be more specific, in the training phase, a feature detector is created based on NMF with manifold regularization by considering color information, which not only allows parts-based manifold representation of an image, but also manifests localized color visual properties. In the quality estimation phase, visually important regions are selected by considering different human visual attention, and feature vectors are extracted by using the feature detector. Then the feature similarity index is calculated and the parts-based manifold color feature energy (PMCFE) for each view is defined based on the color feature vectors. The final quality score is obtained by considering a binocular combination based on PMCFE. The experimental results on LIVE I and LIVE Π 3-D IQA databases demonstrate that the proposed method can achieve much higher consistency with subjective evaluations than the state-of-the-art SIQA methods.

  13. Texas lignite and the visual resource: an objective approach to visual resource evaluation and management

    Treesearch

    Harlow C. Landphair

    1979-01-01

    This paper relates the evolution of an empirical model used to predict public response to scenic quality objectively. The text relates the methods used to develop the visual quality index model, explains the terms used in the equation and briefly illustrates how the model is applied and how it is tested. While the technical application of the model relies heavily on...

  14. Evaluation of Barrier Skin Cream Effectiveness Against JP-8 Jet Fuel Absorption and Irritation

    DTIC Science & Technology

    2009-04-01

    quantify the colorimeter measurements. This system uses spectral chromaticity coordinates and corresponding color- matching functions based on...in the caudal thigh or lumbar muscles and the rabbit was monitored throughout the procedure. Once anesthetized, a baseline visual and colorimeter ...Visual Scoring Technique All barrier creams were scored in 3 ways; by visual scoring described in the Draize method, by colorimeter , and by

  15. Visual versus mechanised leucocyte differential counts: costing and evaluation of traditional and Hemalog D methods.

    PubMed

    Hudson, M J; Green, A E

    1980-11-01

    Visual differential counts were examined for efficiency, cost effectiveness, and staff acceptability within our laboratory. A comparison with the Hemalog D system was attempted. The advantages and disadvantages of each system are enumerated and discussed in the context of a large general hospital.

  16. Disability Insurance Beneficiaries with Visual Impairments in Vocational Rehabilitation: Socio-Demographic Influences on Employment

    ERIC Educational Resources Information Center

    Giesen, J. Martin; Cavenaugh, Brenda S.

    2013-01-01

    Introduction: Given mutual concerns of vocational rehabilitation and the Social Security Administration, our purpose was to evaluate the effect of current individual and economic factors on competitive employment for Social Security Disability Insurance (SSDI) beneficiaries with visual impairments in vocational rehabilitation. Methods: Using…

  17. An odor identification approach based on event-related pupil dilation and gaze focus.

    PubMed

    Aguillon-Hernandez, Nadia; Naudin, Marine; Roché, Laëtitia; Bonnet-Brilhault, Frédérique; Belzung, Catherine; Martineau, Joëlle; Atanasova, Boriana

    2015-06-01

    Olfactory disorders constitute a potential marker of many diseases and are considered valuable clues to the diagnosis and evaluation of progression for many disorders. The most commonly used test for the evaluation of impairments of olfactory identification requires the active participation of the subject, who must select the correct name of the perceived odor from a list. An alternative method is required because speech may be impaired or not yet learned in many patients. As odor identification is known to be facilitated by searching for visual clues, we aimed to develop an objective, vision-based approach for the evaluation of odor identification. We used an eye tracking method to quantify pupillary and ocular responses during the simultaneous presentation of olfactory and visual stimuli, in 39 healthy participants aged from 19 to 77years. Odor presentation triggered an increase in pupil dilation and gaze focus on the picture corresponding to the odor presented. These results suggest that odorant stimuli increase recruitment of the sympathetic system (as demonstrated by the reactivity of the pupil) and draw attention to the visual clue. These results validate the objectivity of this method. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Impact of cataract surgery on vision-related life performances: the usefulness of Real-Life Vision Test for cataract surgery outcomes evaluation

    PubMed Central

    Ni, W; Li, X; Hou, Z; Zhang, H; Qiu, W; Wang, W

    2015-01-01

    Purpose Real-Life Vision Test (RLVT) is a newly developed performance-based measures of functional vision. This present study is designed to determine whether it could be a meaningful assessment for cataract surgery outcomes evaluation. Patients and methods Age-related cataract patients (56) who scheduled for bilateral cataract surgery and 44 age-matched controls were evaluated by four types of measurements: (1) demographic, medical, cognitive and depressive evaluation, and the reaction time testing; (2) clinical measures (visual acuity, contrast sensitivity, stereopsis, and color perception); (3) the 25-item National Eye Institute's Visual Functioning Questionnaire (NEI-VFQ); (4) the RLVT. Spearman's coefficients and multiple regression analysis were conducted to investigate the relationship among RLVT, clinical measures, and self-report assessment of visual function. Results The results of RLVT, clinical measures, and NEI-VFQ total scores were improved significantly after cataract surgery. There were no differences between control subjects and post-surgery patients with respect to NEI-VFQ-25 total scores, self-rating depression scale scores and three tasks of RLVT. Change of RLVT was significantly associated with the change of clinical measures in the cataract group. Multiple regression analysis demonstrated that change of distance, intermediate, and near visual acuity, and binocular contrast sensitivity were significant predictors of improvements of RLVT. Conclusions Cataract surgery could improve real-world visual ability effectively for cataract patients. Our study highlights the potential usefulness of RLVT as an adjunct to the current outcomes evaluation system for cataract surgery. The use of RLVT combined with clinical and self-survey methods may be the comprehensive strategy to manifest the impact of cataract surgery on patients' overall vision-related quality of life. PMID:26272444

  19. Indocyanine green fluorescence imaging in hepatobiliary surgery.

    PubMed

    Majlesara, Ali; Golriz, Mohammad; Hafezi, Mohammadreza; Saffari, Arash; Stenau, Esther; Maier-Hein, Lena; Müller-Stich, Beat P; Mehrabi, Arianeb

    2017-03-01

    Indocyanine green (ICG) is a fluorescent dye that has been widely used for fluorescence imaging during hepatobiliary surgery. ICG is injected intravenously, selectively taken up by the liver, and then secreted into the bile. The catabolism and fluorescence properties of ICG permit a wide range of visualization methods in hepatobiliary surgery. We have characterized the applications of ICG during hepatobiliary surgery into: 1) liver mapping, 2) cholangiography, 3) tumor visualization, and 4) partial liver graft evaluation. In this literature review, we summarize the current understanding of ICG use during hepatobiliary surgery. Intra-operative ICG fluorescence imaging is a safe, simple, and feasible method that improves the visualization of hepatobiliary anatomy and liver tumors. Intravenous administration of ICG is not toxic and avoids the drawbacks of conventional imaging. In addition, it reduces post-operative complications without any known side effects. ICG fluorescence imaging provides a safe and reliable contrast for extra-hepatic cholangiography when detecting intra-hepatic bile leakage following liver resection. In addition, liver tumors can be visualized and well-differentiated hepatocellular carcinoma tumors can be accurately identified. Moreover, vascular reconstruction and outflow can be evaluated following partial liver transplantation. However, since tissue penetration is limited to 5-10mm, deeper tissue cannot be visualized using this method. Many instances of false positive or negative results have been reported, therefore further characterization is required. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Principle and engineering implementation of 3D visual representation and indexing of medical diagnostic records (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Shi, Liehang; Sun, Jianyong; Yang, Yuanyuan; Ling, Tonghui; Wang, Mingqing; Zhang, Jianguo

    2017-03-01

    Purpose: Due to the generation of a large number of electronic imaging diagnostic records (IDR) year after year in a digital hospital, The IDR has become the main component of medical big data which brings huge values to healthcare services, professionals and administration. But a large volume of IDR presented in a hospital also brings new challenges to healthcare professionals and services as there may be too many IDRs for each patient so that it is difficult for a doctor to review all IDR of each patient in a limited appointed time slot. In this presentation, we presented an innovation method which uses an anatomical 3D structure object visually to represent and index historical medical status of each patient, which is called Visual Patient (VP) in this presentation, based on long term archived electronic IDR in a hospital, so that a doctor can quickly learn the historical medical status of the patient, quickly point and retrieve the IDR he or she interested in a limited appointed time slot. Method: The engineering implementation of VP was to build 3D Visual Representation and Index system called VP system (VPS) including components of natural language processing (NLP) for Chinese, Visual Index Creator (VIC), and 3D Visual Rendering Engine.There were three steps in this implementation: (1) an XML-based electronic anatomic structure of human body for each patient was created and used visually to index the all of abstract information of each IDR for each patient; (2)a number of specific designed IDR parsing processors were developed and used to extract various kinds of abstract information of IDRs retrieved from hospital information systems; (3) a 3D anatomic rendering object was introduced visually to represent and display the content of VIO for each patient. Results: The VPS was implemented in a simulated clinical environment including PACS/RIS to show VP instance to doctors. We setup two evaluation scenario in a hospital radiology department to evaluate whether radiologists accept the VPS and how the VP impact the radiologists' efficiency and accuracy in reviewing historic medical records of the patients. We got a statistical results showing that more than 70% participated radiologist would like to use the VPS in their radiological imaging services. In comparison testing of using VPS and RIS/PACS in reviewing historic medical records of the patients, we got a statistical result showing that the efficiency of using VPS was higher than that of using PACS/RIS. New Technologies and Results to be presented: This presentation presented an innovation method to use an anatomical 3D structure object, called VP, visually to represent and index historical medical records such as IDR of each patient and a doctor can quickly learn the historical medical status of the patient through VPS. The evaluation results showed that VPS has better performance than RIS-integrated PACS in efficiency of reviewing historic medical records of the patients. Conclusions: In this presentation, we presented an innovation method called VP to use an anatomical 3D structure object visually to represent and index historical IDR of each patient and briefed an engineering implementation to build a VPS to implement the major features and functions of VP. We setup two evaluation scenarios in a hospital radiology department to evaluate VPS and achieved evaluation results showed that VPS has better performance than RIS-integrated PACS in efficiency of reviewing historic medical records of the patients.

  1. Evaluation of accuracy of shade selection using two spectrophotometer systems: Vita Easyshade and Degudent Shadepilot

    PubMed Central

    Kalantari, Mohammad Hassan; Ghoraishian, Seyed Ahmad; Mohaghegh, Mina

    2017-01-01

    Objective: The aim of this in vitro study was to evaluate the accuracy of shade matching using two spectrophotometric devices. Materials and Methods: Thirteen patients who require a full coverage restoration for one of their maxillary central incisors were selected while the adjacent central incisor was intact. 3 same frameworks were constructed for each tooth using computer-aided design and computer-aided manufacturing technology. Shade matching was performed using Vita Easyshade spectrophotometer, Shadepilot spectrophotometer, and Vitapan classical shade guide for the first, second, and third crown subsequently. After application, firing, and glazing of the porcelain, the color was evaluated and scored by five inspectors. Results: Both spectrophotometric systems showed significantly better results than visual method (P < 0.05) while there were no significant differences between Vita Easyshade and Shadepilot spectrophotometers (P < 0.05). Conclusion: Spectrophotometers are a good substitute for visual color selection methods. PMID:28729792

  2. Icarus: visualizer for de novo assembly evaluation.

    PubMed

    Mikheenko, Alla; Valin, Gleb; Prjibelski, Andrey; Saveliev, Vladislav; Gurevich, Alexey

    2016-11-01

    : Data visualization plays an increasingly important role in NGS data analysis. With advances in both sequencing and computational technologies, it has become a new bottleneck in genomics studies. Indeed, evaluation of de novo genome assemblies is one of the areas that can benefit from the visualization. However, even though multiple quality assessment methods are now available, existing visualization tools are hardly suitable for this purpose. Here, we present Icarus-a novel genome visualizer for accurate assessment and analysis of genomic draft assemblies, which is based on the tool QUAST. Icarus can be used in studies where a related reference genome is available, as well as for non-model organisms. The tool is available online and as a standalone application. http://cab.spbu.ru/software/icarus CONTACT: aleksey.gurevich@spbu.ruSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. Effectiveness of Video Demonstration over Conventional Methods in Teaching Osteology in Anatomy.

    PubMed

    Viswasom, Angela A; Jobby, Abraham

    2017-02-01

    Technology and its applications are the most happening things in the world. So, is it in the field of medical education. This study was an evaluation of whether the conventional methods can compete with the test of technology. A comparative study of traditional method of teaching osteology in human anatomy with an innovative visual aided method. The study was conducted on 94 students admitted to MBBS 2014 to 2015 batch of Travancore Medical College. The students were divided into two academically validated groups. They were taught using conventional and video demonstrational techniques in a systematic manner. Post evaluation tests were conducted. Analysis of the mark pattern revealed that the group taught using traditional method scored better when compared to the visual aided method. Feedback analysis showed that, the students were able to identify bony features better with clear visualisation and three dimensional view when taught using the video demonstration method. The students identified visual aided method as the more interesting one for learning which helped them in applying the knowledge gained. In most of the questions asked, the two methods of teaching were found to be comparable on the same scale. As the study ends, we discover that, no new technique can be substituted for time tested techniques of teaching and learning. The ideal method would be incorporating newer multimedia techniques into traditional classes.

  4. An Evaluation of the Effectiveness of a Computer-Assisted Reading Intervention

    ERIC Educational Resources Information Center

    Messer, David; Nash, Gilly

    2018-01-01

    Background: A cost-effective method to address reading delays is to use computer-assisted learning, but these techniques are not always effective. Methods: We evaluated a commercially available computer system that uses visual mnemonics, in a randomised controlled trial with 78 English-speaking children (mean age 7 years) who their schools…

  5. Evaluating color deficiency simulation and daltonization methods through visual search and sample-to-match: SaMSEM and ViSDEM

    NASA Astrophysics Data System (ADS)

    Simon-Liedtke, Joschua T.; Farup, Ivar; Laeng, Bruno

    2015-01-01

    Color deficient people might be confronted with minor difficulties when navigating through daily life, for example when reading websites or media, navigating with maps, retrieving information from public transport schedules and others. Color deficiency simulation and daltonization methods have been proposed to better understand problems of color deficient individuals and to improve color displays for their use. However, it remains unclear whether these color prosthetic" methods really work and how well they improve the performance of color deficient individuals. We introduce here two methods to evaluate color deficiency simulation and daltonization methods based on behavioral experiments that are widely used in the field of psychology. Firstly, we propose a Sample-to-Match Simulation Evaluation Method (SaMSEM); secondly, we propose a Visual Search Daltonization Evaluation Method (ViSDEM). Both methods can be used to validate and allow the generalization of the simulation and daltonization methods related to color deficiency. We showed that both the response times (RT) and the accuracy of SaMSEM can be used as an indicator of the success of color deficiency simulation methods and that performance in the ViSDEM can be used as an indicator for the efficacy of color deficiency daltonization methods. In future work, we will include comparison and analysis of different color deficiency simulation and daltonization methods with the help of SaMSEM and ViSDEM.

  6. Evaluation of Chemical Preparation on Insect Wing Shape for Geometric Morphometrics

    PubMed Central

    Lorenz, Camila; Suesdek, Lincoln

    2013-01-01

    Geometric morphometrics is an approach that has been increasingly applied in studies with insects. A limiting factor of this technique is that some mosquitoes have wings with dark spots or many scales, which jeopardizes the visualization of landmarks for morphometric analysis. Recently, in some studies, chemically treatment (staining) of the wings was used to improve the viewing of landmarks. In this study, we evaluated whether this method causes deformation of the wing veins and tested whether it facilitates the visualization of the most problematic landmarks. In addition, we tested whether mechanical removal of the scales was sufficient for this purpose. The results showed that the physical and chemical treatments are equally effective in improving visualization of the landmarks. The chemical method did not cause deformation of the wing. Thus, some of these treatments should be performed before beginning geometric morphometric analysis to avoid erroneous landmark digitizing. PMID:24019438

  7. Visual analytics as a translational cognitive science.

    PubMed

    Fisher, Brian; Green, Tera Marie; Arias-Hernández, Richard

    2011-07-01

    Visual analytics is a new interdisciplinary field of study that calls for a more structured scientific approach to understanding the effects of interaction with complex graphical displays on human cognitive processes. Its primary goal is to support the design and evaluation of graphical information systems that better support cognitive processes in areas as diverse as scientific research and emergency management. The methodologies that make up this new field are as yet ill defined. This paper proposes a pathway for development of visual analytics as a translational cognitive science that bridges fundamental research in human/computer cognitive systems and design and evaluation of information systems in situ. Achieving this goal will require the development of enhanced field methods for conceptual decomposition of human/computer cognitive systems that maps onto laboratory studies, and improved methods for conducting laboratory investigations that might better map onto real-world cognitive processes in technology-rich environments. Copyright © 2011 Cognitive Science Society, Inc.

  8. Evaluation of stereoscopic display with visual function and interview

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio

    1999-05-01

    The influence of binocular stereoscopic (3D) television display on the human eye were compared with one of a 2D display, using human visual function testing and interviews. A 40- inch double lenticular display was used for 2D/3D comparison experiments. Subjects observed the display for 30 minutes at a distance 1.0 m, with a combination of 2D material and one of 3D material. The participants were twelve young adults. Main optometric test with visual function measured were visual acuity, refraction, phoria, near vision point, accommodation etc. The interview consisted of 17 questions. Testing procedures were performed just before watching, just after watching, and forty-five minutes after watching. Changes in visual function are characterized as prolongation of near vision point, decrease of accommodation and increase in phoria. 3D viewing interview results show much more visual fatigue in comparison with 2D results. The conclusions are: 1) change in visual function is larger and visual fatigue is more intense when viewing 3D images. 2) The evaluation method with visual function and interview proved to be very satisfactory for analyzing the influence of stereoscopic display on human eye.

  9. Dynamic visual attention: motion direction versus motion magnitude

    NASA Astrophysics Data System (ADS)

    Bur, A.; Wurtz, P.; Müri, R. M.; Hügli, H.

    2008-02-01

    Defined as an attentive process in the context of visual sequences, dynamic visual attention refers to the selection of the most informative parts of video sequence. This paper investigates the contribution of motion in dynamic visual attention, and specifically compares computer models designed with the motion component expressed either as the speed magnitude or as the speed vector. Several computer models, including static features (color, intensity and orientation) and motion features (magnitude and vector) are considered. Qualitative and quantitative evaluations are performed by comparing the computer model output with human saliency maps obtained experimentally from eye movement recordings. The model suitability is evaluated in various situations (synthetic and real sequences, acquired with fixed and moving camera perspective), showing advantages and inconveniences of each method as well as preferred domain of application.

  10. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    PubMed

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p < 0.05). Only the utility scores measured with RS were significantly correlated with the composite OSDI score, "environmental trigger" and "eye discomfort" section scores (p < 0.05). RS is more sensitive than TTO and SG for the evaluation of altered quality of life due to dry eye symptoms.

  11. Application of Multi-Parameter Data Visualization by Means of Multidimensional Scaling to Evaluate Possibility of Coal Gasification

    NASA Astrophysics Data System (ADS)

    Jamróz, Dariusz; Niedoba, Tomasz; Surowiak, Agnieszka; Tumidajski, Tadeusz; Szostek, Roman; Gajer, Mirosław

    2017-09-01

    The application of methods drawing upon multi-parameter visualization of data by transformation of multidimensional space into two-dimensional one allow to show multi-parameter data on computer screen. Thanks to that, it is possible to conduct a qualitative analysis of this data in the most natural way for human being, i.e. by the sense of sight. An example of such method of multi-parameter visualization is multidimensional scaling. This method was used in this paper to present and analyze a set of seven-dimensional data obtained from Janina Mining Plant and Wieczorek Coal Mine. It was decided to examine whether the method of multi-parameter data visualization allows to divide the samples space into areas of various applicability to fluidal gasification process. The "Technological applicability card for coals" was used for this purpose [Sobolewski et al., 2012; 2017], in which the key parameters, important and additional ones affecting the gasification process were described.

  12. Visual versus mechanised leucocyte differential counts: costing and evaluation of traditional and Hemalog D methods.

    PubMed Central

    Hudson, M J; Green, A E

    1980-01-01

    Visual differential counts were examined for efficiency, cost effectiveness, and staff acceptability within our laboratory. A comparison with the Hemalog D system was attempted. The advantages and disadvantages of each system are enumerated and discussed in the context of a large general hospital. PMID:7440760

  13. Using Repeated Reading to Improve Reading Speed and Comprehension in Students with Visual Impairments

    ERIC Educational Resources Information Center

    Savaiano, Mackenzie E.; Hatton, Deborah D.

    2013-01-01

    Introduction: This study evaluated whether children with visual impairments who receive repeated reading instruction exhibit an increase in their oral reading rate and comprehension and a decrease in oral reading error rates. Methods: A single-subject, changing-criterion design replicated across three participants was used to demonstrate the…

  14. A Computer-Based Program to Teach Braille Reading to Sighted Individuals

    ERIC Educational Resources Information Center

    Scheithauer, Mindy C.; Tiger, Jeffrey H.

    2012-01-01

    Instructors of the visually impaired need efficient braille-training methods. This study conducted a preliminary evaluation of a computer-based program intended to teach the relation between braille characters and English letters using a matching-to-sample format with 4 sighted college students. Each participant mastered matching visual depictions…

  15. Enhancing Visual Search Abilities of People with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Li-Tsang, Cecilia W. P.; Wong, Jackson K. K.

    2009-01-01

    This study aimed to evaluate the effects of cueing in visual search paradigm for people with and without intellectual disabilities (ID). A total of 36 subjects (18 persons with ID and 18 persons with normal intelligence) were recruited using convenient sampling method. A series of experiments were conducted to compare guided cue strategies using…

  16. Outcome Results from "Yo Veo": A Visual Intervention for Teachers Working with Immigrant Latino/Latina Students

    ERIC Educational Resources Information Center

    Chapman, Mimi V.; Hall, William J.

    2016-01-01

    Objective: This study reports results from the outcome evaluation of "Yo Veo," a visual intervention with schoolteachers, which structures conversations about challenges that teachers face teaching Latino/Latina immigrant students. Method: The intervention was delivered to teachers at two middle schools in the southeastern United States,…

  17. Developing and evaluating a target-background similarity metric for camouflage detection.

    PubMed

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Liu, Bor-Shong

    2014-01-01

    Measurement of camouflage performance is of fundamental importance for military stealth applications. The goal of camouflage assessment algorithms is to automatically assess the effect of camouflage in agreement with human detection responses. In a previous study, we found that the Universal Image Quality Index (UIQI) correlated well with the psychophysical measures, and it could be a potentially camouflage assessment tool. In this study, we want to quantify the camouflage similarity index and psychophysical results. We compare several image quality indexes for computational evaluation of camouflage effectiveness, and present the results of an extensive human visual experiment conducted to evaluate the performance of several camouflage assessment algorithms and analyze the strengths and weaknesses of these algorithms. The experimental data demonstrates the effectiveness of the approach, and the correlation coefficient result of the UIQI was higher than those of other methods. This approach was highly correlated with the human target-searching results. It also showed that this method is an objective and effective camouflage performance evaluation method because it considers the human visual system and image structure, which makes it consistent with the subjective evaluation results.

  18. Visualizing Mobility of Public Transportation System.

    PubMed

    Zeng, Wei; Fu, Chi-Wing; Arisona, Stefan Müller; Erath, Alexander; Qu, Huamin

    2014-12-01

    Public transportation systems (PTSs) play an important role in modern cities, providing shared/massive transportation services that are essential for the general public. However, due to their increasing complexity, designing effective methods to visualize and explore PTS is highly challenging. Most existing techniques employ network visualization methods and focus on showing the network topology across stops while ignoring various mobility-related factors such as riding time, transfer time, waiting time, and round-the-clock patterns. This work aims to visualize and explore passenger mobility in a PTS with a family of analytical tasks based on inputs from transportation researchers. After exploring different design alternatives, we come up with an integrated solution with three visualization modules: isochrone map view for geographical information, isotime flow map view for effective temporal information comparison and manipulation, and OD-pair journey view for detailed visual analysis of mobility factors along routes between specific origin-destination pairs. The isotime flow map linearizes a flow map into a parallel isoline representation, maximizing the visualization of mobility information along the horizontal time axis while presenting clear and smooth pathways from origin to destinations. Moreover, we devise several interactive visual query methods for users to easily explore the dynamics of PTS mobility over space and time. Lastly, we also construct a PTS mobility model from millions of real passenger trajectories, and evaluate our visualization techniques with assorted case studies with the transportation researchers.

  19. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels

    PubMed Central

    2011-01-01

    Background and purpose Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, and a 3-dimensional (3D) virtual reality (VR) approach in visualizing and measuring ACL reconstruction bone tunnel placement. Methods 50 consecutive patients who underwent single-bundle ACL reconstructions were evaluated postoperatively by standard radiographs, CT scans, and 3D VR images. Tibial and femoral tunnel positions were measured by 2 observers using the traditional methods of Amis, Aglietti, Hoser, Stäubli, and the method of Benereau for the VR approach. Results The tunnel was visualized in 50–82% of the standard radiographs and in 100% of the CT scans and 3D VR images. Using the intraclass correlation coefficient (ICC), the inter- and intraobserver agreement was between 0.39 and 0.83 for the standard femoral and tibial radiographs. CT scans showed an ICC range of 0.49–0.76 for the inter- and intraobserver agreement. The agreement in 3D VR was almost perfect, with an ICC of 0.83 for the femur and 0.95 for the tibia. Interpretation CT scans and 3D VR images are more reliable in assessing postoperative bone tunnel placement following ACL reconstruction than standard radiographs. PMID:21999625

  20. Determination of industrial color tolerance limits: case studies in the textile industry

    NASA Astrophysics Data System (ADS)

    Gay, Jennifer; Hirschler, Robert

    2002-06-01

    The approach and findings during the application of instrumental color quality control in industry are described, where the best tolerance formulae and tolerance limits were determined by correlating visual and instrumental evaluations. A panel of previously tested observers evaluated a collection of samples taken from production and color measurements are then compared to these assessments, according to different color difference formulae. T he formula and the limit giving the best agreement with visual evaluations were determined with two different methods. For a large variety of textile substrates, processes and market situations the CMC(2:1) formula was always the best or one of the bests, but the limits varied widely, according to the individual application. Additional shade sorting, based on the tolerance limit, was also applied in several companies. The ideal box size was also determined by comparing visual and instrumental evaluations. The application as logistical tools was established according to individual necessities.

  1. [Visual perception and its disorders].

    PubMed

    Ruf-Bächtiger, L

    1989-11-21

    It's the brain and not the eye that decides what is perceived. In spite of this fact, quite a lot is known about the functioning of the eye and the first sections of the optic tract, but little about the actual process of perception. Examination of visual perception and its malfunctions relies therefore on certain hypotheses. Proceeding from the model of functional brain systems, variant functional domains of visual perception can be distinguished. Among the more important of these domains are: digit span, visual discrimination and figure-ground discrimination. Evaluation of these functional domains allows us to understand those children with disorders of visual perception better and to develop more effective treatment methods.

  2. TrajGraph: A Graph-Based Visual Analytics Approach to Studying Urban Network Centralities Using Taxi Trajectory Data.

    PubMed

    Huang, Xiaoke; Zhao, Ye; Yang, Jing; Zhang, Chong; Ma, Chao; Ye, Xinyue

    2016-01-01

    We propose TrajGraph, a new visual analytics method, for studying urban mobility patterns by integrating graph modeling and visual analysis with taxi trajectory data. A special graph is created to store and manifest real traffic information recorded by taxi trajectories over city streets. It conveys urban transportation dynamics which can be discovered by applying graph analysis algorithms. To support interactive, multiscale visual analytics, a graph partitioning algorithm is applied to create region-level graphs which have smaller size than the original street-level graph. Graph centralities, including Pagerank and betweenness, are computed to characterize the time-varying importance of different urban regions. The centralities are visualized by three coordinated views including a node-link graph view, a map view and a temporal information view. Users can interactively examine the importance of streets to discover and assess city traffic patterns. We have implemented a fully working prototype of this approach and evaluated it using massive taxi trajectories of Shenzhen, China. TrajGraph's capability in revealing the importance of city streets was evaluated by comparing the calculated centralities with the subjective evaluations from a group of drivers in Shenzhen. Feedback from a domain expert was collected. The effectiveness of the visual interface was evaluated through a formal user study. We also present several examples and a case study to demonstrate the usefulness of TrajGraph in urban transportation analysis.

  3. Similarities in human visual and declared measures of preference for opposite-sex faces.

    PubMed

    Griffey, Jack A F; Little, Anthony C

    2014-01-01

    Facial appearance in humans is associated with attraction and mate choice. Numerous studies have identified that adults display directional preferences for certain facial traits including symmetry, averageness, and sexually dimorphic traits. Typically, studies measuring human preference for these traits examine declared (e.g., choice or ratings of attractiveness) or visual preferences (e.g., looking time) of participants. However, the extent to which visual and declared preferences correspond remains relatively untested. In order to evaluate the relationship between these measures we examined visual and declared preferences displayed by men and women for opposite-sex faces manipulated across three dimensions (symmetry, averageness, and masculinity) and compared preferences from each method. Results indicated that participants displayed significant visual and declared preferences for symmetrical, average, and appropriately sexually dimorphic faces. We also found that declared and visual preferences correlated weakly but significantly. These data indicate that visual and declared preferences for manipulated facial stimuli produce similar directional preferences across participants and are also correlated with one another within participants. Both methods therefore may be considered appropriate to measure human preferences. However, while both methods appear likely to generate similar patterns of preference at the sample level, the weak nature of the correlation between visual and declared preferences in our data suggests some caution in assuming visual preferences are the same as declared preferences at the individual level. Because there are positive and negative factors in both methods for measuring preference, we suggest that a combined approach is most useful in outlining population level preferences for traits.

  4. Dynamic Chest Image Analysis: Evaluation of Model-Based Pulmonary Perfusion Analysis With Pyramid Images

    DTIC Science & Technology

    2001-10-25

    Image Analysis aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the Dynamic Pulmonary Imaging technique 18,5,17,6. We have proposed and evaluated a multiresolutional method with an explicit ventilation model based on pyramid images for ventilation analysis. We have further extended the method for ventilation analysis to pulmonary perfusion. This paper focuses on the clinical evaluation of our method for

  5. Differential diagnosis of solitary pulmonary nodules based on 99mTc-EDDA/HYNIC-TOC scintigraphy: the effect of tumour size on the optimal method of image assessment.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-09-01

    The aim of the study was to determine an optimal method for the evaluation of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC for the purpose of differential diagnosis of solitary pulmonary nodules (SPNs) and to assess the diagnostic value of the method. Eighty-five patients (48 males and 37 females, mean age 57 years, range 34-78 years) were enrolled in the study. Patients underwent (99m)Tc-EDDA/HYNIC-TOC scintigraphy for the purpose of differential diagnosis of SPNs (size between 1 and 4 cm). Images of all patients were evaluated visually in a prospective manner. Positive scintigraphic results were found in 37 out of 40 (93%) patients with malignant SPNs including 34 out of 35 (97%) patients with primary lung carcinoma. Two remaining false negative cases turned out to be metastatic lesions of malignant melanoma and leiomyosarcoma. Among 45 benign tumours, negative results were obtained in 31 cases (69%) and positive results in 14. The accuracy of the method was 80%. Analysis of the results of the visual assessment of scintigrams revealed a significantly higher frequency of false positive results among larger nodules (diameter at least 1.4 cm). Uptake of the tracer in those nodules was therefore assessed semi-quantitatively (using the tumour-to-background ratio), in expectation of an improvement in the low specificity of the visual method. The semi-quantitative assessment reduced the total number of false positive results in a subgroup of larger nodules from 13 to six, while preserving the high sensitivity of the method. The combination of visual analysis (for lesions smaller than 1.4 cm in diameter) and semi-quantitative assessment (for larger lesions) provided a high sensitivity of the method and significantly improved its specificity (84%) and accuracy (88%) in comparison with visual analysis (p<0.05).

  6. Data-Intensive Evaluation: The Concept, Methods, and Prospects of Higher Education Monitoring Evaluation

    ERIC Educational Resources Information Center

    Wang, Zhanjun; Qiao, Weifeng; Li, Jiangbo

    2016-01-01

    Higher education monitoring evaluation is a process that uses modern information technology to continually collect and deeply analyze relevant data, visually present the state of higher education, and provide an objective basis for value judgments and scientific decision making by diverse bodies Higher education monitoring evaluation is…

  7. Interactive visualization for scar transmurality in cardiac resynchronization therapy

    NASA Astrophysics Data System (ADS)

    Reiml, Sabrina; Toth, Daniel; Panayiotou, Maria; Fahn, Bernhard; Karim, Rashed; Behar, Jonathan M.; Rinaldi, Christopher A.; Razavi, Reza; Rhode, Kawal S.; Brost, Alexander; Mountney, Peter

    2016-03-01

    Heart failure is a serious disease affecting about 23 million people worldwide. Cardiac resynchronization therapy is used to treat patients suffering from symptomatic heart failure. However, 30% to 50% of patients have limited clinical benefit. One of the main causes is suboptimal placement of the left ventricular lead. Pacing in areas of myocardial scar correlates with poor clinical outcomes. Therefore precise knowledge of the individual patient's scar characteristics is critical for delivering tailored treatments capable of improving response rates. Current research methods for scar assessment either map information to an alternative non-anatomical coordinate system or they use the image coordinate system but lose critical information about scar extent and scar distribution. This paper proposes two interactive methods for visualizing relevant scar information. A 2-D slice based approach with a scar mask overlaid on a 16 segment heart model and a 3-D layered mesh visualization which allows physicians to scroll through layers of scar from endocardium to epicardium. These complementary methods enable physicians to evaluate scar location and transmurality during planning and guidance. Six physicians evaluated the proposed system by identifying target regions for lead placement. With the proposed method more target regions could be identified.

  8. Coherent Image Layout using an Adaptive Visual Vocabulary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillard, Scott E.; Henry, Michael J.; Bohn, Shawn J.

    When querying a huge image database containing millions of images, the result of the query may still contain many thousands of images that need to be presented to the user. We consider the problem of arranging such a large set of images into a visually coherent layout, one that places similar images next to each other. Image similarity is determined using a bag-of-features model, and the layout is constructed from a hierarchical clustering of the image set by mapping an in-order traversal of the hierarchy tree into a space-filling curve. This layout method provides strong locality guarantees so we aremore » able to quantitatively evaluate performance using standard image retrieval benchmarks. Performance of the bag-of-features method is best when the vocabulary is learned on the image set being clustered. Because learning a large, discriminative vocabulary is a computationally demanding task, we present a novel method for efficiently adapting a generic visual vocabulary to a particular dataset. We evaluate our clustering and vocabulary adaptation methods on a variety of image datasets and show that adapting a generic vocabulary to a particular set of images improves performance on both hierarchical clustering and image retrieval tasks.« less

  9. Clinical Outcomes after Keraring Implantation for Keratoconus Management in Patients Older Than 40 Years: A Retrospective, Interventional, Cohort Study.

    PubMed

    Gatzioufas, Zisis; Khine, Aye; Elalfy, Mohamed; Guber, Ivo; McLintock, Cameron; Sabatino, Francesco; Hamada, Samer; Lake, Damian

    2018-06-01

    Intracorneal ring segment implantation is an effective and safe method of visual improvement in patients with keratoconus. The aim of our study was to evaluate the long-term clinical outcomes after Keraring implantation for keratoconus in patients older than 40 years. Eleven eyes from 11 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. The uncorrected visual acuity (UCVA), corrected visual acuity, keratometric readings, central corneal thickness and thinnest corneal pachymetry were evaluated preoperatively and 6 months after the Keraring implantation. UCVA, BCVA and keratometric readings improved at 6 months postoperatively. Our data showed significant keratometric amelioration and visual improvement after Keraring implantation for keratoconus in patients older than 40 years at 6 months postoperatively.

  10. Reliability and Validity of the Visual, Musculoskeletal, and Balance Complaints Questionnaire

    PubMed Central

    Lundqvist, Lars-Olov; Zetterlund, Christina; Richter, Hans O.

    2016-01-01

    ABSTRACT Purpose To evaluate the reliability and validity of the 15-item Visual, Musculoskeletal, and Balance Complaints Questionnaire (VMB) for people with visual impairments, using confirmatory factor analysis (CFA) and with Rasch analysis for use as an outcome measure. Methods Two studies evaluated the VMB. In Study 1, VMB data were collected from 1249 out of 3063 individuals between 18 and 104 years old who were registered at a low vision center. CFA evaluated VMB factor structure and Rasch analysis evaluated VMB scale properties. In Study 2, a subsample of 52 individuals between 27 and 67 years old with visual impairments underwent further measurements. Visual clinical assessments, neck/scapular pain, and balance assessments were collected to evaluate the convergent validity of the VMB (i.e. the domain relationship with other, theoretically predicted measures). Results CFA supported the a priori three-factor structure of the VMB. The factor loadings of the items on their respective domains were all statistically significant. Rasch analysis indicated disordered categories and the original 10-point scale was subsequently replaced with a 5-point scale. Each VMB domain fitted the Rasch model, showing good metric properties, including unidimensionality (explained variances ≥66% and eigenvalues <1.9), person separation (1.86 to 2.29), reliability (0.87 to 0.94), item fit (infit MnSq’s >0.72 and outfit MnSq’s <1.47), targeting (0.30 to 0.50 logits), and insignificant differential item functioning (all DIFs but one <0.50 logits) from gender, age, and visual status. The three VMB domains correlated significantly with relevant visual, musculoskeletal, and balance assessments, demonstrating adequate convergent validity of the VMB. Conclusions The VMB is a simple, inexpensive, and quick yet reliable and valid way to screen and evaluate concurrent visual, musculoskeletal, and balance complaints, with contribution to epidemiological and intervention research and potential clinical implications for the field of health services and low vision rehabilitation. PMID:27309524

  11. A Graph-Embedding Approach to Hierarchical Visual Word Mergence.

    PubMed

    Wang, Lei; Liu, Lingqiao; Zhou, Luping

    2017-02-01

    Appropriately merging visual words are an effective dimension reduction method for the bag-of-visual-words model in image classification. The approach of hierarchically merging visual words has been extensively employed, because it gives a fully determined merging hierarchy. Existing supervised hierarchical merging methods take different approaches and realize the merging process with various formulations. In this paper, we propose a unified hierarchical merging approach built upon the graph-embedding framework. Our approach is able to merge visual words for any scenario, where a preferred structure and an undesired structure are defined, and, therefore, can effectively attend to all kinds of requirements for the word-merging process. In terms of computational efficiency, we show that our algorithm can seamlessly integrate a fast search strategy developed in our previous work and, thus, well maintain the state-of-the-art merging speed. To the best of our survey, the proposed approach is the first one that addresses the hierarchical visual word mergence in such a flexible and unified manner. As demonstrated, it can maintain excellent image classification performance even after a significant dimension reduction, and outperform all the existing comparable visual word-merging methods. In a broad sense, our work provides an open platform for applying, evaluating, and developing new criteria for hierarchical word-merging tasks.

  12. Visual evoked potentials in the horse.

    PubMed

    Ström, L; Ekesten, B

    2016-06-21

    Electrical potentials generated in the central nervous system in response to brief visual stimuli, flash visual evoked potentials (FVEPs), can be recorded non-invasively over the occipital cortex. FVEPs are used clinically in human medicine and also experimentally in a number of animal species, but the method has not yet been evaluated in the horse. The method would potentially allow the ophthalmologist and equine clinician to evaluate visual impairment caused by disorders affecting post-retinal visual pathways. The aim was to establish a method for recording of FVEPs in horses in a clinical setting and to evaluate the waveform morphology in the normal horse. Ten horses were sedated with a continuous detomidine infusion. Responses were recorded from electrodes placed on the scalp. Several positions were evaluated to determine suitable electrode placement. Flash electroretinograms (FERGs) were recorded simultaneously. To evaluate potential contamination of the FVEP from retinal potentials, a retrobulbar nerve block was performed in two horses and transection of the optic nerve was performed in one horse as a terminal procedure. A series of positive (P) and negative (N) peaks in response to light stimuli was recorded in all horses. Reproducible wavelets with mean times-to-peaks of 26 (N1), 55 (P2), 141 (N2) and 216 ms (P4) were seen in all horses in all recordings. Reproducible results were obtained when the active electrode was placed in the midline rostral to the nuchal crest. Recording at lateral positions gave more variable results, possibly due to ear muscle artifacts. Averaging ≥100 responses reduced the impact of noise and artifacts. FVEPs were reproducible in the same horse during the same recording session and between sessions, but were more variable between horses. Retrobulbar nerve block caused a transient loss of the VEP whereas transection of the optic nerve caused an irreversible loss. We describe the waveform of the equine FVEP and our results show that it is possible to record FVEPs in sedated horses in a clinical setting. The potentials recorded were shown to be of post-retinal origin. Further studies are needed to provide normative data and assess potential clinical use.

  13. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients

    PubMed Central

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-01-01

    Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289

  14. Evaluation of an Audio-Visual Novela to Improve Beliefs, Attitudes and Knowledge toward Dementia: A Mixed-Methods Approach.

    PubMed

    Grigsby, Timothy J; Unger, Jennifer B; Molina, Gregory B; Baron, Mel

    2017-01-01

    Dementia is a clinical syndrome characterized by progressive degeneration in cognitive ability that limits the capacity for independent living. Interventions are needed to target the medical, social, psychological, and knowledge needs of caregivers and patients. This study used a mixed methods approach to evaluate the effectiveness of a dementia novela presented in an audio-visual format in improving dementia attitudes, beliefs and knowledge. Adults from Los Angeles (N = 42, 83% female, 90% Hispanic/Latino, mean age = 42.2 years, 41.5% with less than a high school education) viewed an audio-visual novela on dementia. Participants completed surveys immediately before and after viewing the material. The novela produced significant improvements in overall knowledge (t(41) = -9.79, p < .0001) and led to positive increases in specific attitudes toward people with dementia but not in beliefs that screening would be beneficial. Qualitative results provided concordant and discordant evidence for the quantitative findings. Results indicate that an audio-visual novela can be useful for improving attitudes and knowledge about dementia, but further work is needed to investigate the relation with health disparities in screening and treatment behaviors. Audio visual novelas are an innovative format for health education and change attitudes and knowledge about dementia.

  15. Evaluation of the Effectiveness of a Tablet Computer Application (App) in Helping Students with Visual Impairments Solve Mathematics Problems

    ERIC Educational Resources Information Center

    Beal, Carole R.; Rosenblum, L. Penny

    2018-01-01

    Introduction: The authors examined a tablet computer application (iPad app) for its effectiveness in helping students studying prealgebra to solve mathematical word problems. Methods: Forty-three visually impaired students (that is, those who are blind or have low vision) completed eight alternating mathematics units presented using their…

  16. Perceptions of Teachers of Students with Visual Impairments regarding Assistive Technology: A Follow-Up Study to a University Course

    ERIC Educational Resources Information Center

    Kamei-Hannan, Cheryl; Howe, Jon; Herrera, Robyn Rene; Erin, Jane N.

    2012-01-01

    Introduction: The study presented here examined the learning outcomes of graduate students in visual impairment who were enrolled in an assistive technology course in three university programs. Methods: The students' perceptions of learning were evaluated using pre- and posttests administered during the course. A follow-up questionnaire was…

  17. UNDERSTANDING AND APPLYING ENVIRONMENTAL RELATIVE MOLDINESS INDEX - ERMI

    EPA Science Inventory

    This study compared two binary classification methods to evaluate the mold condition in 271 homes of infants, 144 of which later developed symptoms of respiratory illness. A method using on-site visual mold inspection was compared to another method using a quantitative index of ...

  18. Assessment of composite index methods for agricultural vulnerability to climate change.

    PubMed

    Wiréhn, Lotten; Danielsson, Åsa; Neset, Tina-Simone S

    2015-06-01

    A common way of quantifying and communicating climate vulnerability is to calculate composite indices from indicators, visualizing these as maps. Inherent methodological uncertainties in vulnerability assessments, however, require greater attention. This study examines Swedish agricultural vulnerability to climate change, the aim being to review various indicator approaches for assessing agricultural vulnerability to climate change and to evaluate differences in climate vulnerability depending on the weighting and summarizing methods. The reviewed methods are evaluated by being tested at the municipal level. Three weighting and summarizing methods, representative of climate vulnerability indices in general, are analysed. The results indicate that 34 of 36 method combinations differ significantly from each other. We argue that representing agricultural vulnerability in a single composite index might be insufficient to guide climate adaptation. We emphasize the need for further research into how to measure and visualize agricultural vulnerability and into how to communicate uncertainties in both data and methods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Detection Progress of Selected Drugs in TLC

    PubMed Central

    Pyka, Alina

    2014-01-01

    This entry describes applications of known indicators and dyes as new visualizing reagents and various visualizing systems as well as photocatalytic reactions and bioautography method for the detection of bioactive compounds including drugs and compounds isolated from herbal extracts. Broadening index, detection index, characteristics of densitometric band, modified contrast index, limit of detection, densitometric visualizing index, and linearity range of detected compounds were used for the evaluation of visualizing effects of applied visualizing reagents. It was shown that visualizing effect depends on the chemical structure of the visualizing reagent, the structure of the substance detected, and the chromatographic adsorbent applied. The usefulness of densitometry to direct detection of some drugs was also shown. Quoted papers indicate the detection progress of selected drugs investigated by thin-layer chromatography (TLC). PMID:24551853

  20. A multilevel layout algorithm for visualizing physical and genetic interaction networks, with emphasis on their modular organization

    PubMed Central

    2012-01-01

    Background Graph drawing is an integral part of many systems biology studies, enabling visual exploration and mining of large-scale biological networks. While a number of layout algorithms are available in popular network analysis platforms, such as Cytoscape, it remains poorly understood how well their solutions reflect the underlying biological processes that give rise to the network connectivity structure. Moreover, visualizations obtained using conventional layout algorithms, such as those based on the force-directed drawing approach, may become uninformative when applied to larger networks with dense or clustered connectivity structure. Methods We implemented a modified layout plug-in, named Multilevel Layout, which applies the conventional layout algorithms within a multilevel optimization framework to better capture the hierarchical modularity of many biological networks. Using a wide variety of real life biological networks, we carried out a systematic evaluation of the method in comparison with other layout algorithms in Cytoscape. Results The multilevel approach provided both biologically relevant and visually pleasant layout solutions in most network types, hence complementing the layout options available in Cytoscape. In particular, it could improve drawing of large-scale networks of yeast genetic interactions and human physical interactions. In more general terms, the biological evaluation framework developed here enables one to assess the layout solutions from any existing or future graph drawing algorithm as well as to optimize their performance for a given network type or structure. Conclusions By making use of the multilevel modular organization when visualizing biological networks, together with the biological evaluation of the layout solutions, one can generate convenient visualizations for many network biology applications. PMID:22448851

  1. A study of the laminar separation bubble on an airfoil at low Reynolds numbers using flow visualization techniques

    NASA Technical Reports Server (NTRS)

    Schmidt, Gordon S.; Mueller, Thomas J.

    1987-01-01

    The use of flow visualization to study separation bubbles is evaluated. The wind tunnel, two NACA 66(3)-018 airfoil models, and kerosene vapor, titanium tetrachloride, and surface flow visualizations techniques are described. The application of the three visualization techniques to the two airfoil models reveals that the smoke and vapor techniques provide data on the location of laminar separation and the onset of transition, and the surface method produces information about the location of turbulent boundary layer separation. The data obtained with the three flow visualization techniques are compared to pressure distribution data and good correlation is detected. It is noted that flow visualization is an effective technique for examining separation bubbles.

  2. High-resolution STIR for 3-T MRI of the posterior fossa: visualization of the lower cranial nerves and arteriovenous structures related to neurovascular compression.

    PubMed

    Hiwatashi, Akio; Yoshiura, Takashi; Yamashita, Koji; Kamano, Hironori; Honda, Hiroshi

    2012-09-01

    Preoperative evaluation of small vessels without contrast material is sometimes difficult in patients with neurovascular compression disease. The purpose of this retrospective study was to evaluate whether 3D STIR MRI could simultaneously depict the lower cranial nerves--fifth through twelfth--and the blood vessels in the posterior fossa. The posterior fossae of 47 adults (26 women, 21 men) without gross pathologic changes were imaged with 3D STIR and turbo spin-echo heavily T2-weighted MRI sequences and with contrast-enhanced turbo field-echo MR angiography (MRA). Visualization of the cranial nerves on STIR images was graded on a 4-point scale and compared with visualization on T2-weighted images. Visualization of the arteries on STIR images was evaluated according to the segments in each artery and compared with that on MRA images. Visualization of the veins on STIR images was also compared with that on MRA images. Statistical analysis was performed with the Mann-Whitney U test. There were no significant differences between STIR and T2-weighted images with respect to visualization of the cranial nerves (p > 0.05). Identified on STIR and MRA images were 94 superior cerebellar arteries, 81 anteroinferior cerebellar arteries, and 79 posteroinferior cerebellar arteries. All veins evaluated were seen on STIR and MRA images. There were no significant differences between STIR and MRA images with respect to visualization of arteries and veins (p > 0.05). High-resolution STIR is a feasible method for simultaneous evaluation of the lower cranial nerves and the vessels in the posterior fossa without the use of contrast material.

  3. Analysing the physics learning environment of visually impaired students in high schools

    NASA Astrophysics Data System (ADS)

    Toenders, Frank G. C.; de Putter-Smits, Lesley G. A.; Sanders, Wendy T. M.; den Brok, Perry

    2017-07-01

    Although visually impaired students attend regular high school, their enrolment in advanced science classes is dramatically low. In our research we evaluated the physics learning environment of a blind high school student in a regular Dutch high school. For visually impaired students to grasp physics concepts, time and additional materials to support the learning process are key. Time for teachers to develop teaching methods for such students is scarce. Suggestions for changes to the learning environment and of materials used are given.

  4. Visual soil evaluation - future research requirements

    NASA Astrophysics Data System (ADS)

    Emmet-Booth, Jeremy; Forristal, Dermot; Fenton, Owen; Ball, Bruce; Holden, Nick

    2017-04-01

    A review of Visual Soil Evaluation (VSE) techniques (Emmet-Booth et al., 2016) highlighted their established utility for soil quality assessment, though some limitations were identified; (1) The examination of aggregate size, visible intra-porosity and shape forms a key assessment criterion in almost all methods, thus limiting evaluation to structural form. The addition of criteria that holistically examine structure may be desirable. For example, structural stability can be indicated using dispersion tests or examining soil surface crusting, while the assessment of soil colour may indirectly indicate soil organic matter content, a contributor to stability. Organic matter assessment may also indicate structural resilience, along with rooting, earthworm numbers or shrinkage cracking. (2) Soil texture may influence results or impeded method deployment. Modification of procedures to account for extreme texture variation is desirable. For example, evidence of compaction in sandy or single grain soils greatly differs to that in clayey soils. Some procedures incorporate separate classification systems or adjust deployment based on texture. (3) Research into impacts of soil moisture content on VSE evaluation criteria is required. Criteria such as rupture resistance and shape may be affected by moisture content. It is generally recommended that methods are deployed on moist soils and quantification of influences of moisture variation on results is necessary. (4) Robust sampling strategies for method deployment are required. Dealing with spatial variation differs between methods, but where methods can be deployed over large areas, clear instruction on sampling is required. Additionally, as emphasis has been placed on the agricultural production of soil, so the ability of VSE for exploring structural quality in terms of carbon storage, water purification and biodiversity support also requires research. References Emmet-Booth, J.P., Forristal. P.D., Fenton, O., Ball, B.C. & Holden, N.M. 2016. A review of visual soil evaluation techniques for soil structure. Soil Use and Management, 32, 623-634.

  5. The pedagogical toolbox: computer-generated visual displays, classroom demonstration, and lecture.

    PubMed

    Bockoven, Jerry

    2004-06-01

    This analogue study compared the effectiveness of computer-generated visual displays, classroom demonstration, and traditional lecture as methods of instruction used to teach neuronal structure and processes. Randomly assigned 116 undergraduate students participated in 1 of 3 classrooms in which they experienced the same content but different teaching approaches presented by 3 different student-instructors. Then participants completed a survey of their subjective reactions and a measure of factual information designed to evaluate objective learning outcomes. Participants repeated this factual measure 5 wk. later. Results call into question the use of classroom demonstration methods as well as the trend towards devaluing traditional lecture in favor of computer-generated visual display.

  6. Web accessibility support for visually impaired users using link content analysis.

    PubMed

    Iwata, Hajime; Kobayashi, Naofumi; Tachibana, Kenji; Shirogane, Junko; Fukazawa, Yoshiaki

    2013-12-01

    Web pages are used for a variety of purposes. End users must understand dynamically changing content and sequentially follow page links to find desired material, requiring significant time and effort. However, for visually impaired users using screen readers, it can be difficult to find links to web pages when link text and alternative text descriptions are inappropriate. Our method supports the discovery of content by analyzing 8 categories of link types, and allows visually impaired users to be aware of the content represented by links in advance. This facilitates end users access to necessary information on web pages. Our method of classifying web page links is therefore effective as a means of evaluating accessibility.

  7. Quantitative evaluation methods of skin condition based on texture feature parameters.

    PubMed

    Pang, Hui; Chen, Tianhua; Wang, Xiaoyi; Chang, Zhineng; Shao, Siqi; Zhao, Jing

    2017-03-01

    In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM) is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  8. An Information-Theoretic-Cluster Visualization for Self-Organizing Maps.

    PubMed

    Brito da Silva, Leonardo Enzo; Wunsch, Donald C

    2018-06-01

    Improved data visualization will be a significant tool to enhance cluster analysis. In this paper, an information-theoretic-based method for cluster visualization using self-organizing maps (SOMs) is presented. The information-theoretic visualization (IT-vis) has the same structure as the unified distance matrix, but instead of depicting Euclidean distances between adjacent neurons, it displays the similarity between the distributions associated with adjacent neurons. Each SOM neuron has an associated subset of the data set whose cardinality controls the granularity of the IT-vis and with which the first- and second-order statistics are computed and used to estimate their probability density functions. These are used to calculate the similarity measure, based on Renyi's quadratic cross entropy and cross information potential (CIP). The introduced visualizations combine the low computational cost and kernel estimation properties of the representative CIP and the data structure representation of a single-linkage-based grouping algorithm to generate an enhanced SOM-based visualization. The visual quality of the IT-vis is assessed by comparing it with other visualization methods for several real-world and synthetic benchmark data sets. Thus, this paper also contains a significant literature survey. The experiments demonstrate the IT-vis cluster revealing capabilities, in which cluster boundaries are sharply captured. Additionally, the information-theoretic visualizations are used to perform clustering of the SOM. Compared with other methods, IT-vis of large SOMs yielded the best results in this paper, for which the quality of the final partitions was evaluated using external validity indices.

  9. Enhancing Learning Management Systems Utility for Blind Students: A Task-Oriented, User-Centered, Multi-Method Evaluation Technique

    ERIC Educational Resources Information Center

    Babu, Rakesh; Singh, Rahul

    2013-01-01

    This paper presents a novel task-oriented, user-centered, multi-method evaluation (TUME) technique and shows how it is useful in providing a more complete, practical and solution-oriented assessment of the accessibility and usability of Learning Management Systems (LMS) for blind and visually impaired (BVI) students. Novel components of TUME…

  10. Personal sleep pattern visualization using sequence-based kernel self-organizing map on sound data.

    PubMed

    Wu, Hongle; Kato, Takafumi; Yamada, Tomomi; Numao, Masayuki; Fukui, Ken-Ichi

    2017-07-01

    We propose a method to discover sleep patterns via clustering of sound events recorded during sleep. The proposed method extends the conventional self-organizing map algorithm by kernelization and sequence-based technologies to obtain a fine-grained map that visualizes the distribution and changes of sleep-related events. We introduced features widely applied in sound processing and popular kernel functions to the proposed method to evaluate and compare performance. The proposed method provides a new aspect of sleep monitoring because the results demonstrate that sound events can be directly correlated to an individual's sleep patterns. In addition, by visualizing the transition of cluster dynamics, sleep-related sound events were found to relate to the various stages of sleep. Therefore, these results empirically warrant future study into the assessment of personal sleep quality using sound data. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Web-Based Assessment of Visual and Visuospatial Symptoms in Parkinson's Disease

    PubMed Central

    Amick, Melissa M.; Miller, Ivy N.; Neargarder, Sandy; Cronin-Golomb, Alice

    2012-01-01

    Visual and visuospatial dysfunction is prevalent in Parkinson's disease (PD). To promote assessment of these often overlooked symptoms, we adapted the PD Vision Questionnaire for Internet administration. The questionnaire evaluates visual and visuospatial symptoms, impairments in activities of daily living (ADLs), and motor symptoms. PD participants of mild to moderate motor severity (n = 24) and healthy control participants (HC, n = 23) completed the questionnaire in paper and web-based formats. Reliability was assessed by comparing responses across formats. Construct validity was evaluated by reference to performance on measures of vision, visuospatial cognition, ADLs, and motor symptoms. The web-based format showed excellent reliability with respect to the paper format for both groups (all P′s < 0.001; HC completing the visual and visuospatial section only). Demonstrating the construct validity of the web-based questionnaire, self-rated ADL and visual and visuospatial functioning were significantly associated with performance on objective measures of these abilities (all P′s < 0.01). The findings indicate that web-based administration may be a reliable and valid method of assessing visual and visuospatial and ADL functioning in PD. PMID:22530162

  12. Fuzzy Classification of High Resolution Remote Sensing Scenes Using Visual Attention Features.

    PubMed

    Li, Linyi; Xu, Tingbao; Chen, Yun

    2017-01-01

    In recent years the spatial resolutions of remote sensing images have been improved greatly. However, a higher spatial resolution image does not always lead to a better result of automatic scene classification. Visual attention is an important characteristic of the human visual system, which can effectively help to classify remote sensing scenes. In this study, a novel visual attention feature extraction algorithm was proposed, which extracted visual attention features through a multiscale process. And a fuzzy classification method using visual attention features (FC-VAF) was developed to perform high resolution remote sensing scene classification. FC-VAF was evaluated by using remote sensing scenes from widely used high resolution remote sensing images, including IKONOS, QuickBird, and ZY-3 images. FC-VAF achieved more accurate classification results than the others according to the quantitative accuracy evaluation indices. We also discussed the role and impacts of different decomposition levels and different wavelets on the classification accuracy. FC-VAF improves the accuracy of high resolution scene classification and therefore advances the research of digital image analysis and the applications of high resolution remote sensing images.

  13. Fuzzy Classification of High Resolution Remote Sensing Scenes Using Visual Attention Features

    PubMed Central

    Xu, Tingbao; Chen, Yun

    2017-01-01

    In recent years the spatial resolutions of remote sensing images have been improved greatly. However, a higher spatial resolution image does not always lead to a better result of automatic scene classification. Visual attention is an important characteristic of the human visual system, which can effectively help to classify remote sensing scenes. In this study, a novel visual attention feature extraction algorithm was proposed, which extracted visual attention features through a multiscale process. And a fuzzy classification method using visual attention features (FC-VAF) was developed to perform high resolution remote sensing scene classification. FC-VAF was evaluated by using remote sensing scenes from widely used high resolution remote sensing images, including IKONOS, QuickBird, and ZY-3 images. FC-VAF achieved more accurate classification results than the others according to the quantitative accuracy evaluation indices. We also discussed the role and impacts of different decomposition levels and different wavelets on the classification accuracy. FC-VAF improves the accuracy of high resolution scene classification and therefore advances the research of digital image analysis and the applications of high resolution remote sensing images. PMID:28761440

  14. Magnetic resonance in studies of glaucoma

    PubMed Central

    Fiedorowicz, Michał; Dyda, Wojciech; Rejdak, Robert; Grieb, Paweł

    2011-01-01

    Summary Glaucoma is the second leading cause of blindness. It affects retinal ganglion cells and the optic nerve. However, there is emerging evidence that glaucoma also affects other components of the visual pathway and visual cortex. There is a need to employ new methods of in vivo brain evaluation to characterize these changes. Magnetic resonance (MR) techniques are well suited for this purpose. We review data on the MR evaluation of the visual pathway and the use of MR techniques in the study of glaucoma, both in humans and in animal models. These studies demonstrated decreases in optic nerve diameter, localized white matter loss and decrease in visual cortex density. Studies on rats employing manganese-enhanced MRI showed that axonal transport in the optic nerve is affected. Diffusion tensor MRI revealed signs of degeneration of the optic pathway. Functional MRI showed decreased response of the visual cortex after stimulation of the glaucomatous eye. Magnetic resonance spectroscopy demonstrated changes in metabolite levels in the visual cortex in a rat model of glaucoma, although not in glaucoma patients. Further applications of MR techniques in studies of glaucomatous brains are indicated. PMID:21959626

  15. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

    PubMed

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-07-27

    The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.

  16. Evaluation of non-destructive methods for estimating biomass in marshes of the upper Texas, USA coast

    USGS Publications Warehouse

    Whitbeck, M.; Grace, J.B.

    2006-01-01

    The estimation of aboveground biomass is important in the management of natural resources. Direct measurements by clipping, drying, and weighing of herbaceous vegetation are time-consuming and costly. Therefore, non-destructive methods for efficiently and accurately estimating biomass are of interest. We compared two non-destructive methods, visual obstruction and light penetration, for estimating aboveground biomass in marshes of the upper Texas, USA coast. Visual obstruction was estimated using the Robel pole method, which primarily measures the density and height of the canopy. Light penetration through the canopy was measured using a Decagon light wand, with readings taken above the vegetation and at the ground surface. Clip plots were also taken to provide direct estimates of total aboveground biomass. Regression relationships between estimated and clipped biomass were significant using both methods. However, the light penetration method was much more strongly correlated with clipped biomass under these conditions (R2 value 0.65 compared to 0.35 for the visual obstruction approach). The primary difference between the two methods in this situation was the ability of the light-penetration method to account for variations in plant litter. These results indicate that light-penetration measurements may be better for estimating biomass in marshes when plant litter is an important component. We advise that, in all cases, investigators should calibrate their methods against clip plots to evaluate applicability to their situation. ?? 2006, The Society of Wetland Scientists.

  17. Direct-location versus verbal report methods for measuring auditory distance perception in the far field.

    PubMed

    Etchemendy, Pablo E; Spiousas, Ignacio; Calcagno, Esteban R; Abregú, Ezequiel; Eguia, Manuel C; Vergara, Ramiro O

    2018-06-01

    In this study we evaluated whether a method of direct location is an appropriate response method for measuring auditory distance perception of far-field sound sources. We designed an experimental set-up that allows participants to indicate the distance at which they perceive the sound source by moving a visual marker. We termed this method Cross-Modal Direct Location (CMDL) since the response procedure involves the visual modality while the stimulus is presented through the auditory modality. Three experiments were conducted with sound sources located from 1 to 6 m. The first one compared the perceived distances obtained using either the CMDL device or verbal report (VR), which is the response method more frequently used for reporting auditory distance in the far field, and found differences on response compression and bias. In Experiment 2, participants reported visual distance estimates to the visual marker that were found highly accurate. Then, we asked the same group of participants to report VR estimates of auditory distance and found that the spatial visual information, obtained from the previous task, did not influence their reports. Finally, Experiment 3 compared the same responses that Experiment 1 but interleaving the methods, showing a weak, but complex, mutual influence. However, the estimates obtained with each method remained statistically different. Our results show that the auditory distance psychophysical functions obtained with the CMDL method are less susceptible to previously reported underestimation for distances over 2 m.

  18. Virtual Environments for Visualizing Structural Health Monitoring Sensor Networks, Data, and Metadata.

    PubMed

    Napolitano, Rebecca; Blyth, Anna; Glisic, Branko

    2018-01-16

    Visualization of sensor networks, data, and metadata is becoming one of the most pivotal aspects of the structural health monitoring (SHM) process. Without the ability to communicate efficiently and effectively between disparate groups working on a project, an SHM system can be underused, misunderstood, or even abandoned. For this reason, this work seeks to evaluate visualization techniques in the field, identify flaws in current practices, and devise a new method for visualizing and accessing SHM data and metadata in 3D. More precisely, the work presented here reflects a method and digital workflow for integrating SHM sensor networks, data, and metadata into a virtual reality environment by combining spherical imaging and informational modeling. Both intuitive and interactive, this method fosters communication on a project enabling diverse practitioners of SHM to efficiently consult and use the sensor networks, data, and metadata. The method is presented through its implementation on a case study, Streicker Bridge at Princeton University campus. To illustrate the efficiency of the new method, the time and data file size were compared to other potential methods used for visualizing and accessing SHM sensor networks, data, and metadata in 3D. Additionally, feedback from civil engineering students familiar with SHM is used for validation. Recommendations on how different groups working together on an SHM project can create SHM virtual environment and convey data to proper audiences, are also included.

  19. Virtual Environments for Visualizing Structural Health Monitoring Sensor Networks, Data, and Metadata

    PubMed Central

    Napolitano, Rebecca; Blyth, Anna; Glisic, Branko

    2018-01-01

    Visualization of sensor networks, data, and metadata is becoming one of the most pivotal aspects of the structural health monitoring (SHM) process. Without the ability to communicate efficiently and effectively between disparate groups working on a project, an SHM system can be underused, misunderstood, or even abandoned. For this reason, this work seeks to evaluate visualization techniques in the field, identify flaws in current practices, and devise a new method for visualizing and accessing SHM data and metadata in 3D. More precisely, the work presented here reflects a method and digital workflow for integrating SHM sensor networks, data, and metadata into a virtual reality environment by combining spherical imaging and informational modeling. Both intuitive and interactive, this method fosters communication on a project enabling diverse practitioners of SHM to efficiently consult and use the sensor networks, data, and metadata. The method is presented through its implementation on a case study, Streicker Bridge at Princeton University campus. To illustrate the efficiency of the new method, the time and data file size were compared to other potential methods used for visualizing and accessing SHM sensor networks, data, and metadata in 3D. Additionally, feedback from civil engineering students familiar with SHM is used for validation. Recommendations on how different groups working together on an SHM project can create SHM virtual environment and convey data to proper audiences, are also included. PMID:29337877

  20. Inferring Interaction Force from Visual Information without Using Physical Force Sensors.

    PubMed

    Hwang, Wonjun; Lim, Soo-Chul

    2017-10-26

    In this paper, we present an interaction force estimation method that uses visual information rather than that of a force sensor. Specifically, we propose a novel deep learning-based method utilizing only sequential images for estimating the interaction force against a target object, where the shape of the object is changed by an external force. The force applied to the target can be estimated by means of the visual shape changes. However, the shape differences in the images are not very clear. To address this problem, we formulate a recurrent neural network-based deep model with fully-connected layers, which models complex temporal dynamics from the visual representations. Extensive evaluations show that the proposed learning models successfully estimate the interaction forces using only the corresponding sequential images, in particular in the case of three objects made of different materials, a sponge, a PET bottle, a human arm, and a tube. The forces predicted by the proposed method are very similar to those measured by force sensors.

  1. Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples.

    PubMed

    Berger, Jason; Upton, Colin; Springer, Elyah

    2018-04-23

    Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.

  2. StreamExplorer: A Multi-Stage System for Visually Exploring Events in Social Streams.

    PubMed

    Wu, Yingcai; Chen, Zhutian; Sun, Guodao; Xie, Xiao; Cao, Nan; Liu, Shixia; Cui, Weiwei

    2017-10-18

    Analyzing social streams is important for many applications, such as crisis management. However, the considerable diversity, increasing volume, and high dynamics of social streams of large events continue to be significant challenges that must be overcome to ensure effective exploration. We propose a novel framework by which to handle complex social streams on a budget PC. This framework features two components: 1) an online method to detect important time periods (i.e., subevents), and 2) a tailored GPU-assisted Self-Organizing Map (SOM) method, which clusters the tweets of subevents stably and efficiently. Based on the framework, we present StreamExplorer to facilitate the visual analysis, tracking, and comparison of a social stream at three levels. At a macroscopic level, StreamExplorer uses a new glyph-based timeline visualization, which presents a quick multi-faceted overview of the ebb and flow of a social stream. At a mesoscopic level, a map visualization is employed to visually summarize the social stream from either a topical or geographical aspect. At a microscopic level, users can employ interactive lenses to visually examine and explore the social stream from different perspectives. Two case studies and a task-based evaluation are used to demonstrate the effectiveness and usefulness of StreamExplorer.Analyzing social streams is important for many applications, such as crisis management. However, the considerable diversity, increasing volume, and high dynamics of social streams of large events continue to be significant challenges that must be overcome to ensure effective exploration. We propose a novel framework by which to handle complex social streams on a budget PC. This framework features two components: 1) an online method to detect important time periods (i.e., subevents), and 2) a tailored GPU-assisted Self-Organizing Map (SOM) method, which clusters the tweets of subevents stably and efficiently. Based on the framework, we present StreamExplorer to facilitate the visual analysis, tracking, and comparison of a social stream at three levels. At a macroscopic level, StreamExplorer uses a new glyph-based timeline visualization, which presents a quick multi-faceted overview of the ebb and flow of a social stream. At a mesoscopic level, a map visualization is employed to visually summarize the social stream from either a topical or geographical aspect. At a microscopic level, users can employ interactive lenses to visually examine and explore the social stream from different perspectives. Two case studies and a task-based evaluation are used to demonstrate the effectiveness and usefulness of StreamExplorer.

  3. Making data matter: Voxel printing for the digital fabrication of data across scales and domains.

    PubMed

    Bader, Christoph; Kolb, Dominik; Weaver, James C; Sharma, Sunanda; Hosny, Ahmed; Costa, João; Oxman, Neri

    2018-05-01

    We present a multimaterial voxel-printing method that enables the physical visualization of data sets commonly associated with scientific imaging. Leveraging voxel-based control of multimaterial three-dimensional (3D) printing, our method enables additive manufacturing of discontinuous data types such as point cloud data, curve and graph data, image-based data, and volumetric data. By converting data sets into dithered material deposition descriptions, through modifications to rasterization processes, we demonstrate that data sets frequently visualized on screen can be converted into physical, materially heterogeneous objects. Our approach alleviates the need to postprocess data sets to boundary representations, preventing alteration of data and loss of information in the produced physicalizations. Therefore, it bridges the gap between digital information representation and physical material composition. We evaluate the visual characteristics and features of our method, assess its relevance and applicability in the production of physical visualizations, and detail the conversion of data sets for multimaterial 3D printing. We conclude with exemplary 3D-printed data sets produced by our method pointing toward potential applications across scales, disciplines, and problem domains.

  4. Visual memories for perceived length are well preserved in older adults.

    PubMed

    Norman, J Farley; Holmin, Jessica S; Bartholomew, Ashley N

    2011-09-15

    Three experiments compared younger (mean age was 23.7years) and older (mean age was 72.1years) observers' ability to visually discriminate line length using both explicit and implicit standard stimuli. In Experiment 1, the method of constant stimuli (with an explicit standard) was used to determine difference thresholds, whereas the method of single stimuli (where the knowledge of the standard length was only implicit and learned from previous test stimuli) was used in Experiments 2 and 3. The study evaluated whether increases in age affect older observers' ability to learn, retain, and utilize effective implicit visual standards. Overall, the observers' length difference thresholds were 5.85% of the standard when the method of constant stimuli was used and improved to 4.39% of the standard for the method of single stimuli (a decrease of 25%). Both age groups performed similarly in all conditions. The results demonstrate that older observers retain the ability to create, remember, and utilize effective implicit standards from a series of visual stimuli. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

    PubMed

    Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A

    2014-01-01

    Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  6. Intraoperative acceleration measurements to quantify improvement in tremor during deep brain stimulation surgery.

    PubMed

    Shah, Ashesh; Coste, Jérôme; Lemaire, Jean-Jacques; Taub, Ethan; Schüpbach, W M Michael; Pollo, Claudio; Schkommodau, Erik; Guzman, Raphael; Hemm-Ode, Simone

    2017-05-01

    Deep brain stimulation (DBS) surgery is extensively used in the treatment of movement disorders. Nevertheless, methods to evaluate the clinical response during intraoperative stimulation tests to identify the optimal position for the implantation of the chronic DBS lead remain subjective. In this paper, we describe a new, versatile method for quantitative intraoperative evaluation of improvement in tremor with an acceleration sensor that is mounted on the patient's wrist during surgery. At each anatomical test position, the improvement in tremor compared to the initial tremor is estimated on the basis of extracted outcome measures. This method was tested on 15 tremor patients undergoing DBS surgery in two centers. Data from 359 stimulation tests were acquired. Our results suggest that accelerometric evaluation detects tremor changes more sensitively than subjective visual ratings. The effective stimulation current amplitudes identified from the quantitative data (1.1 ± 0.8 mA) are lower than those identified by visual evaluation (1.7 ± 0.8 mA) for similar improvement in tremor. Additionally, if these data had been used to choose the chronic implant position of the DBS lead, 15 of the 26 choices would have been different. These results show that our method of accelerometric evaluation can potentially improve DBS targeting.

  7. Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma.

    PubMed

    Kothari, Ruchi; Bokariya, Pradeep; Singh, Ramji; Singh, Smita; Narang, Purvasha

    2014-01-01

    To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation (PSD) of Humphrey visual field could be associated with visual evoked potential (VEP) parameters of patients having primary open angle glaucoma (POAG). Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential (PRVEP) were assessed in 100 patients with POAG. The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated (full field) and displayed on VEP monitor (colour 14″) by an electronic pattern regenerator inbuilt in an evoked potential recorder (RMS EMG EP MARK II). The results of our study indicate that there is a highly significant (P<0.001) negative correlation of P100 amplitude and a statistically significant (P<0.05) positive correlation of N70 latency, P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student's t-test. Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values. Conversely, as PSD increases the magnitude of VEP excursions were found to be diminished.

  8. Single-case research design in pediatric psychology: considerations regarding data analysis.

    PubMed

    Cohen, Lindsey L; Feinstein, Amanda; Masuda, Akihiko; Vowles, Kevin E

    2014-03-01

    Single-case research allows for an examination of behavior and can demonstrate the functional relation between intervention and outcome in pediatric psychology. This review highlights key assumptions, methodological and design considerations, and options for data analysis. Single-case methodology and guidelines are reviewed with an in-depth focus on visual and statistical analyses. Guidelines allow for the careful evaluation of design quality and visual analysis. A number of statistical techniques have been introduced to supplement visual analysis, but to date, there is no consensus on their recommended use in single-case research design. Single-case methodology is invaluable for advancing pediatric psychology science and practice, and guidelines have been introduced to enhance the consistency, validity, and reliability of these studies. Experts generally agree that visual inspection is the optimal method of analysis in single-case design; however, statistical approaches are becoming increasingly evaluated and used to augment data interpretation.

  9. Bag-of-features based medical image retrieval via multiple assignment and visual words weighting.

    PubMed

    Wang, Jingyan; Li, Yongping; Zhang, Ying; Wang, Chao; Xie, Honglan; Chen, Guoling; Gao, Xin

    2011-11-01

    Bag-of-features based approaches have become prominent for image retrieval and image classification tasks in the past decade. Such methods represent an image as a collection of local features, such as image patches and key points with scale invariant feature transform (SIFT) descriptors. To improve the bag-of-features methods, we first model the assignments of local descriptors as contribution functions, and then propose a novel multiple assignment strategy. Assuming the local features can be reconstructed by their neighboring visual words in a vocabulary, reconstruction weights can be solved by quadratic programming. The weights are then used to build contribution functions, resulting in a novel assignment method, called quadratic programming (QP) assignment. We further propose a novel visual word weighting method. The discriminative power of each visual word is analyzed by the sub-similarity function in the bin that corresponds to the visual word. Each sub-similarity function is then treated as a weak classifier. A strong classifier is learned by boosting methods that combine those weak classifiers. The weighting factors of the visual words are learned accordingly. We evaluate the proposed methods on medical image retrieval tasks. The methods are tested on three well-known data sets, i.e., the ImageCLEFmed data set, the 304 CT Set, and the basal-cell carcinoma image set. Experimental results demonstrate that the proposed QP assignment outperforms the traditional nearest neighbor assignment, the multiple assignment, and the soft assignment, whereas the proposed boosting based weighting strategy outperforms the state-of-the-art weighting methods, such as the term frequency weights and the term frequency-inverse document frequency weights.

  10. Glaucoma progression detection: agreement, sensitivity, and specificity of expert visual field evaluation, event analysis, and trend analysis.

    PubMed

    Antón, Alfonso; Pazos, Marta; Martín, Belén; Navero, José Manuel; Ayala, Miriam Eleonora; Castany, Marta; Martínez, Patricia; Bardavío, Javier

    2013-01-01

    To assess sensitivity, specificity, and agreement among automated event analysis, automated trend analysis, and expert evaluation to detect glaucoma progression. This was a prospective study that included 37 eyes with a follow-up of 36 months. All had glaucomatous disks and fields and performed reliable visual fields every 6 months. Each series of fields was assessed with 3 different methods: subjective assessment by 2 independent teams of glaucoma experts, glaucoma/guided progression analysis (GPA) event analysis, and GPA (visual field index-based) trend analysis. Kappa agreement coefficient between methods and sensitivity and specificity for each method using expert opinion as gold standard were calculated. The incidence of glaucoma progression was 16% to 18% in 3 years but only 3 cases showed progression with all 3 methods. Kappa agreement coefficient was high (k=0.82) between subjective expert assessment and GPA event analysis, and only moderate between these two and GPA trend analysis (k=0.57). Sensitivity and specificity for GPA event and GPA trend analysis were 71% and 96%, and 57% and 93%, respectively. The 3 methods detected similar numbers of progressing cases. The GPA event analysis and expert subjective assessment showed high agreement between them and moderate agreement with GPA trend analysis. In a period of 3 years, both methods of GPA analysis offered high specificity, event analysis showed 83% sensitivity, and trend analysis had a 66% sensitivity.

  11. Reliability and validity of the Microsoft Kinect for evaluating static foot posture

    PubMed Central

    2013-01-01

    Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934

  12. TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, H; Tan, J; Kavanaugh, J

    Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-timemore » and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.« less

  13. Developing and Evaluating a Target-Background Similarity Metric for Camouflage Detection

    PubMed Central

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Liu, Bor-Shong

    2014-01-01

    Background Measurement of camouflage performance is of fundamental importance for military stealth applications. The goal of camouflage assessment algorithms is to automatically assess the effect of camouflage in agreement with human detection responses. In a previous study, we found that the Universal Image Quality Index (UIQI) correlated well with the psychophysical measures, and it could be a potentially camouflage assessment tool. Methodology In this study, we want to quantify the camouflage similarity index and psychophysical results. We compare several image quality indexes for computational evaluation of camouflage effectiveness, and present the results of an extensive human visual experiment conducted to evaluate the performance of several camouflage assessment algorithms and analyze the strengths and weaknesses of these algorithms. Significance The experimental data demonstrates the effectiveness of the approach, and the correlation coefficient result of the UIQI was higher than those of other methods. This approach was highly correlated with the human target-searching results. It also showed that this method is an objective and effective camouflage performance evaluation method because it considers the human visual system and image structure, which makes it consistent with the subjective evaluation results. PMID:24498310

  14. DEVELOPMENT OF THE EPA RELATIVE MOLDINESS INDEX© AND ITS RELATIONSHIP TO HEALTH

    EPA Science Inventory

    This study compared two binary classification methods to evaluate the mold condition in 271 homes of infants, 144 of which later developed symptoms of respiratory illness. A method using on-site visual mold inspection was compared to another method using a quantitative index of ...

  15. Object Recognition in Mental Representations: Directions for Exploring Diagnostic Features through Visual Mental Imagery.

    PubMed

    Roldan, Stephanie M

    2017-01-01

    One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation.

  16. Object Recognition in Mental Representations: Directions for Exploring Diagnostic Features through Visual Mental Imagery

    PubMed Central

    Roldan, Stephanie M.

    2017-01-01

    One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation. PMID:28588538

  17. Eccentric correction for off-axis vision in central visual field loss.

    PubMed

    Gustafsson, Jörgen; Unsbo, Peter

    2003-07-01

    Subjects with absolute central visual field loss use eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects. Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction. Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction. The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.

  18. Efficient visualization of urban spaces

    NASA Astrophysics Data System (ADS)

    Stamps, A. E.

    2012-10-01

    This chapter presents a new method for calculating efficiency and applies that method to the issues of selecting simulation media and evaluating the contextual fit of new buildings in urban spaces. The new method is called "meta-analysis". A meta-analytic review of 967 environments indicated that static color simulations are the most efficient media for visualizing urban spaces. For contextual fit, four original experiments are reported on how strongly five factors influence visual appeal of a street: architectural style, trees, height of a new building relative to the heights of existing buildings, setting back a third story, and distance. A meta-analysis of these four experiments and previous findings, covering 461 environments, indicated that architectural style, trees, and height had effects strong enough to warrant implementation, but the effects of setting back third stories and distance were too small to warrant implementation.

  19. The development of an indoor mobility course for the evaluation of electronic mobility aids for persons who are visually impaired.

    PubMed

    Roentgen, Uta R; Gelderblom, Gert Jan; de Witte, Luc P

    2012-01-01

    To develop a suitable mobility course for the assessment of mobility performance as part of a user evaluation of Electronic Mobility Aids (EMA) aimed at obstacle detection and orientation. A review of the literature led to a list of critical factors for the assessment of mobility performance of persons who are visually impaired. Based upon that list, method, test situations, and determining elements were selected and presented to Dutch orientation and mobility experts. Due to expert advice and a pilot study, minor changes were made and the final version was used for the evaluation of two EMA by eight persons who are visually impaired. The results of the literature study are summarized in an overview of critical factors for the assessment of the mobility performance of persons who are visually impaired. Applied to the requirements of the above mentioned user evaluation a replicable indoor mobility course has been described in detail and tested. Based upon evidence from literature an indoor mobility course has been developed, which was sensitive to assess differences in mobility incidents and obstacle detection when using an EMA compared to the regular mobility aid. Experts' opinion confirmed its face and content validity.

  20. How Can Visual Analytics Assist Investigative Analysis? Design Implications from an Evaluation.

    PubMed

    Youn-Ah Kang; Görg, Carsten; Stasko, John

    2011-05-01

    Despite the growing number of systems providing visual analytic support for investigative analysis, few empirical studies of the potential benefits of such systems have been conducted, particularly controlled, comparative evaluations. Determining how such systems foster insight and sensemaking is important for their continued growth and study, however. Furthermore, studies that identify how people use such systems and why they benefit (or not) can help inform the design of new systems in this area. We conducted an evaluation of the visual analytics system Jigsaw employed in a small investigative sensemaking exercise, and compared its use to three other more traditional methods of analysis. Sixteen participants performed a simulated intelligence analysis task under one of the four conditions. Experimental results suggest that Jigsaw assisted participants to analyze the data and identify an embedded threat. We describe different analysis strategies used by study participants and how computational support (or the lack thereof) influenced the strategies. We then illustrate several characteristics of the sensemaking process identified in the study and provide design implications for investigative analysis tools based thereon. We conclude with recommendations on metrics and techniques for evaluating visual analytics systems for investigative analysis.

  1. Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid

    PubMed Central

    Gorczynska, Iwona; Migacz, Justin V.; Zawadzki, Robert J.; Capps, Arlie G.; Werner, John S.

    2016-01-01

    We compared the performance of three OCT angiography (OCTA) methods: speckle variance, amplitude decorrelation and phase variance for imaging of the human retina and choroid. Two averaging methods, split spectrum and volume averaging, were compared to assess the quality of the OCTA vascular images. All data were acquired using a swept-source OCT system at 1040 nm central wavelength, operating at 100,000 A-scans/s. We performed a quantitative comparison using a contrast-to-noise (CNR) metric to assess the capability of the three methods to visualize the choriocapillaris layer. For evaluation of the static tissue noise suppression in OCTA images we proposed to calculate CNR between the photoreceptor/RPE complex and the choriocapillaris layer. Finally, we demonstrated that implementation of intensity-based OCT imaging and OCT angiography methods allows for visualization of retinal and choroidal vascular layers known from anatomic studies in retinal preparations. OCT projection imaging of data flattened to selected retinal layers was implemented to visualize retinal and choroidal vasculature. User guided vessel tracing was applied to segment the retinal vasculature. The results were visualized in a form of a skeletonized 3D model. PMID:27231598

  2. Automatic multi-label annotation of abdominal CT images using CBIR

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; Antani, Sameer; Long, L. Rodney; Thoma, George R.

    2017-03-01

    We present a technique to annotate multiple organs shown in 2-D abdominal/pelvic CT images using CBIR. This annotation task is motivated by our research interests in visual question-answering (VQA). We aim to apply results from this effort in Open-iSM, a multimodal biomedical search engine developed by the National Library of Medicine (NLM). Understanding visual content of biomedical images is a necessary step for VQA. Though sufficient annotational information about an image may be available in related textual metadata, not all may be useful as descriptive tags, particularly for anatomy on the image. In this paper, we develop and evaluate a multi-label image annotation method using CBIR. We evaluate our method on two 2-D CT image datasets we generated from 3-D volumetric data obtained from a multi-organ segmentation challenge hosted in MICCAI 2015. Shape and spatial layout information is used to encode visual characteristics of the anatomy. We adapt a weighted voting scheme to assign multiple labels to the query image by combining the labels of the images identified as similar by the method. Key parameters that may affect the annotation performance, such as the number of images used in the label voting and the threshold for excluding labels that have low weights, are studied. The method proposes a coarse-to-fine retrieval strategy which integrates the classification with the nearest-neighbor search. Results from our evaluation (using the MICCAI CT image datasets as well as figures from Open-i) are presented.

  3. Performance of multiple docking and refinement methods in the pose prediction D3R prospective Grand Challenge 2016

    NASA Astrophysics Data System (ADS)

    Fradera, Xavier; Verras, Andreas; Hu, Yuan; Wang, Deping; Wang, Hongwu; Fells, James I.; Armacost, Kira A.; Crespo, Alejandro; Sherborne, Brad; Wang, Huijun; Peng, Zhengwei; Gao, Ying-Duo

    2018-01-01

    We describe the performance of multiple pose prediction methods for the D3R 2016 Grand Challenge. The pose prediction challenge includes 36 ligands, which represent 4 chemotypes and some miscellaneous structures against the FXR ligand binding domain. In this study we use a mix of fully automated methods as well as human-guided methods with considerations of both the challenge data and publicly available data. The methods include ensemble docking, colony entropy pose prediction, target selection by molecular similarity, molecular dynamics guided pose refinement, and pose selection by visual inspection. We evaluated the success of our predictions by method, chemotype, and relevance of publicly available data. For the overall data set, ensemble docking, visual inspection, and molecular dynamics guided pose prediction performed the best with overall mean RMSDs of 2.4, 2.2, and 2.2 Å respectively. For several individual challenge molecules, the best performing method is evaluated in light of that particular ligand. We also describe the protein, ligand, and public information data preparations that are typical of our binding mode prediction workflow.

  4. A preliminary study of MR sickness evaluation using visual motion aftereffect for advanced driver assistance systems.

    PubMed

    Nakajima, Sawako; Ino, Shuichi; Ifukube, Tohru

    2007-01-01

    Mixed Reality (MR) technologies have recently been explored in many areas of Human-Machine Interface (HMI) such as medicine, manufacturing, entertainment and education. However MR sickness, a kind of motion sickness is caused by sensory conflicts between the real world and virtual world. The purpose of this paper is to find out a new evaluation method of motion and MR sickness. This paper investigates a relationship between the whole-body vibration related to MR technologies and the motion aftereffect (MAE) phenomenon in the human visual system. This MR environment is modeled after advanced driver assistance systems in near-future vehicles. The seated subjects in the MR simulator were shaken in the pitch direction ranging from 0.1 to 2.0 Hz. Results show that MAE is useful for evaluation of MR sickness incidence. In addition, a method to reduce the MR sickness by auditory stimulation is proposed.

  5. Evaluation of accuracy of shade selection using two spectrophotometer systems: Vita Easyshade and Degudent Shadepilot.

    PubMed

    Kalantari, Mohammad Hassan; Ghoraishian, Seyed Ahmad; Mohaghegh, Mina

    2017-01-01

    The aim of this in vitro study was to evaluate the accuracy of shade matching using two spectrophotometric devices. Thirteen patients who require a full coverage restoration for one of their maxillary central incisors were selected while the adjacent central incisor was intact. 3 same frameworks were constructed for each tooth using computer-aided design and computer-aided manufacturing technology. Shade matching was performed using Vita Easyshade spectrophotometer, Shadepilot spectrophotometer, and Vitapan classical shade guide for the first, second, and third crown subsequently. After application, firing, and glazing of the porcelain, the color was evaluated and scored by five inspectors. Both spectrophotometric systems showed significantly better results than visual method ( P < 0.05) while there were no significant differences between Vita Easyshade and Shadepilot spectrophotometers ( P < 0.05). Spectrophotometers are a good substitute for visual color selection methods.

  6. Inclusive Competitive Game Play Through Balanced Sensory Feedback.

    PubMed

    Westin, Thomas; Söderström, David; Karlsson, Olov; Peiris, Ranil

    2017-01-01

    While game accessibility has improved significantly the last few years, there are still barriers for equal participation and multiplayer issues have been less researched. Game balance is here about making the game fair in a player versus player competitive game. One difficult design task is to balance the game to be fair regardless of visual or hearing capabilities, with clearly different requirements. This paper explores a tentative design method for enabling inclusive competitive game-play without individual adaptations of game rules that could spoil the game. The method involved applying a unified design method to design an unbalanced game, then modifying visual feedback as a hypothetical balanced design, and testing the game with totally 52 people with and without visual or hearing disabilities in three workshops. Game balance was evaluated based on score differences and less structured qualitative data, and a redesign of the game was made. Conclusions are a tentative method for balancing a multiplayer, competitive game without changing game rules and how the method can be applied.

  7. Clinical evaluation of accommodation and ocular surface stability relavant to visual asthenopia with 3D displays

    PubMed Central

    2014-01-01

    Background To validate the association between accommodation and visual asthenopia by measuring objective accommodative amplitude with the Optical Quality Analysis System (OQAS®, Visiometrics, Terrassa, Spain), and to investigate associations among accommodation, ocular surface instability, and visual asthenopia while viewing 3D displays. Methods Fifteen normal adults without any ocular disease or surgical history watched the same 3D and 2D displays for 30 minutes. Accommodative ability, ocular protection index (OPI), and total ocular symptom scores were evaluated before and after viewing the 3D and 2D displays. Accommodative ability was evaluated by the near point of accommodation (NPA) and OQAS to ensure reliability. The OPI was calculated by dividing the tear breakup time (TBUT) by the interblink interval (IBI). The changes in accommodative ability, OPI, and total ocular symptom scores after viewing 3D and 2D displays were evaluated. Results Accommodative ability evaluated by NPA and OQAS, OPI, and total ocular symptom scores changed significantly after 3D viewing (p = 0.005, 0.003, 0.006, and 0.003, respectively), but yielded no difference after 2D viewing. The objective measurement by OQAS verified the decrease of accommodative ability while viewing 3D displays. The change of NPA, OPI, and total ocular symptom scores after 3D viewing had a significant correlation (p < 0.05), implying direct associations among these factors. Conclusions The decrease of accommodative ability after 3D viewing was validated by both subjective and objective methods in our study. Further, the deterioration of accommodative ability and ocular surface stability may be causative factors of visual asthenopia in individuals viewing 3D displays. PMID:24612686

  8. Visualization and simulation techniques for surgical simulators using actual patient's data.

    PubMed

    Radetzky, Arne; Nürnberger, Andreas

    2002-11-01

    Because of the increasing complexity of surgical interventions research in surgical simulation became more and more important over the last years. However, the simulation of tissue deformation is still a challenging problem, mainly due to the short response times that are required for real-time interaction. The demands to hard and software are even larger if not only the modeled human anatomy is used but the anatomy of actual patients. This is required if the surgical simulator should be used as training medium for expert surgeons rather than students. In this article, suitable visualization and simulation methods for surgical simulation utilizing actual patient's datasets are described. Therefore, the advantages and disadvantages of direct and indirect volume rendering for the visualization are discussed and a neuro-fuzzy system is described, which can be used for the simulation of interactive tissue deformations. The neuro-fuzzy system makes it possible to define the deformation behavior based on a linguistic description of the tissue characteristics or to learn the dynamics by using measured data of real tissue. Furthermore, a simulator for minimally-invasive neurosurgical interventions is presented that utilizes the described visualization and simulation methods. The structure of the simulator is described in detail and the results of a system evaluation by an experienced neurosurgeon--a quantitative comparison between different methods of virtual endoscopy as well as a comparison between real brain images and virtual endoscopies--are given. The evaluation proved that the simulator provides a higher realism of the visualization and simulation then other currently available simulators. Copyright 2002 Elsevier Science B.V.

  9. Evidence flowers: An innovative, visual method of presenting "best evidence" summaries to health professional and lay audiences.

    PubMed

    Babatunde, O O; Tan, V; Jordan, J L; Dziedzic, K; Chew-Graham, C A; Jinks, C; Protheroe, J; van der Windt, D A

    2018-06-01

    Barriers to dissemination and engagement with evidence pose a threat to implementing evidence-based medicine. Understanding, retention, and recall can be enhanced by visual presentation of information. The aim of this exploratory research was to develop and evaluate the accessibility and acceptability of visual summaries for presenting evidence syntheses with multiple exposures or outcomes to professional and lay audiences. "Evidence flowers" were developed as a visual method of presenting data from 4 case scenarios: 2 complex evidence syntheses with multiple outcomes, Cochrane reviews, and clinical guidelines. Petals of evidence flowers were coloured according to the GRADE evidence rating system to display key findings and recommendations from the evidence summaries. Application of evidence flowers was observed during stakeholder workshops. Evaluation and feedback were conducted via questionnaires and informal interviews. Feedback from stakeholders on the evidence flowers collected from workshops, questionnaires, and interviews was encouraging and helpful for refining the design of the flowers. Comments were made on the content and design of the flowers, as well as the usability and potential for displaying different types of evidence. Evidence flowers are a novel and visually stimulating method for presenting research evidence from evidence syntheses with multiple exposures or outcomes, Cochrane reviews, and clinical guidelines. To promote access and engagement with research evidence, evidence flowers may be used in conjunction with other evidence synthesis products, such as (lay) summaries, evidence inventories, rapid reviews, and clinical guidelines. Additional research on potential adaptations and applications of the evidence flowers may further bridge the gap between research evidence and clinical practice. Copyright © 2018 John Wiley & Sons, Ltd.

  10. Methods of scaling threshold color difference using printed samples

    NASA Astrophysics Data System (ADS)

    Huang, Min; Cui, Guihua; Liu, Haoxue; Luo, M. Ronnier

    2012-01-01

    A series of printed samples on substrate of semi-gloss paper and with the magnitude of threshold color difference were prepared for scaling the visual color difference and to evaluate the performance of different method. The probabilities of perceptibly was used to normalized to Z-score and different color differences were scaled to the Z-score. The visual color difference was got, and checked with the STRESS factor. The results indicated that only the scales have been changed but the relative scales between pairs in the data are preserved.

  11. The SCHEIE Visual Field Grading System

    PubMed Central

    Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan

    2017-01-01

    Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621

  12. Anomaly Detection in Nanofibrous Materials by CNN-Based Self-Similarity.

    PubMed

    Napoletano, Paolo; Piccoli, Flavio; Schettini, Raimondo

    2018-01-12

    Automatic detection and localization of anomalies in nanofibrous materials help to reduce the cost of the production process and the time of the post-production visual inspection process. Amongst all the monitoring methods, those exploiting Scanning Electron Microscope (SEM) imaging are the most effective. In this paper, we propose a region-based method for the detection and localization of anomalies in SEM images, based on Convolutional Neural Networks (CNNs) and self-similarity. The method evaluates the degree of abnormality of each subregion of an image under consideration by computing a CNN-based visual similarity with respect to a dictionary of anomaly-free subregions belonging to a training set. The proposed method outperforms the state of the art.

  13. Image feature extraction based on the camouflage effectiveness evaluation

    NASA Astrophysics Data System (ADS)

    Yuan, Xin; Lv, Xuliang; Li, Ling; Wang, Xinzhu; Zhang, Zhi

    2018-04-01

    The key step of camouflage effectiveness evaluation is how to combine the human visual physiological features, psychological features to select effectively evaluation indexes. Based on the predecessors' camo comprehensive evaluation method, this paper chooses the suitable indexes combining with the image quality awareness, and optimizes those indexes combining with human subjective perception. Thus, it perfects the theory of index extraction.

  14. Accuracy of Blood Loss Measurement during Cesarean Delivery.

    PubMed

    Doctorvaladan, Sahar V; Jelks, Andrea T; Hsieh, Eric W; Thurer, Robert L; Zakowski, Mark I; Lagrew, David C

    2017-04-01

    Objective  This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design  In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland-Altman method. Results  Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R 2  = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R 2  = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R 2  = 0.304). Conclusion  During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes.

  15. Accuracy of Blood Loss Measurement during Cesarean Delivery

    PubMed Central

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland–Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes. PMID:28497007

  16. [The application of vector analysis for evaluation of astigmatism correction in the corneal refractive surgery].

    PubMed

    Zhang, Jiamei; Wang, Yan

    2016-01-01

    Since sixty percent of ametropes obtain astigmatism, which has influence on the visual quality, correcting the astigmatism is always the focus of concerns during visual correction procedures especially for the corneal refractive surgery. The postoperative spherical equivalent or residual cylindrical dioptors was used as quantitative index to evaluate the correction of astigmatism previously; however, such results neglect the effect of astigmatic axis shift on the treatment. Taking astigmatism as a vector parameter could describe the magnitude and direction of astigmatism accurately, thus it was increasingly applied in the evaluation of astigmatism correction. This paper reviews the present vector analysis methods, evaluation indexes and its application for the correction of astigmatism in the corneal refractive surgery.

  17. Engineering visualization utilizing advanced animation

    NASA Technical Reports Server (NTRS)

    Sabionski, Gunter R.; Robinson, Thomas L., Jr.

    1989-01-01

    Engineering visualization is the use of computer graphics to depict engineering analysis and simulation in visual form from project planning through documentation. Graphics displays let engineers see data represented dynamically which permits the quick evaluation of results. The current state of graphics hardware and software generally allows the creation of two types of 3D graphics. The use of animated video as an engineering visualization tool is presented. The engineering, animation, and videography aspects of animated video production are each discussed. Specific issues include the integration of staffing expertise, hardware, software, and the various production processes. A detailed explanation of the animation process reveals the capabilities of this unique engineering visualization method. Automation of animation and video production processes are covered and future directions are proposed.

  18. Man-systems evaluation of moving base vehicle simulation motion cues. [human acceleration perception involving visual feedback

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, M.; Brye, R. G.

    1974-01-01

    A motion cue investigation program is reported that deals with human factor aspects of high fidelity vehicle simulation. General data on non-visual motion thresholds and specific threshold values are established for use as washout parameters in vehicle simulation. A general purpose similator is used to test the contradictory cue hypothesis that acceleration sensitivity is reduced during a vehicle control task involving visual feedback. The simulator provides varying acceleration levels. The method of forced choice is based on the theory of signal detect ability.

  19. Visualization of simulated urban spaces: inferring parameterized generation of streets, parcels, and aerial imagery.

    PubMed

    Vanegas, Carlos A; Aliaga, Daniel G; Benes, Bedrich; Waddell, Paul

    2009-01-01

    Urban simulation models and their visualization are used to help regional planning agencies evaluate alternative transportation investments, land use regulations, and environmental protection policies. Typical urban simulations provide spatially distributed data about number of inhabitants, land prices, traffic, and other variables. In this article, we build on a synergy of urban simulation, urban visualization, and computer graphics to automatically infer an urban layout for any time step of the simulation sequence. In addition to standard visualization tools, our method gathers data of the original street network, parcels, and aerial imagery and uses the available simulation results to infer changes to the original urban layout and produce a new and plausible layout for the simulation results. In contrast with previous work, our approach automatically updates the layout based on changes in the simulation data and thus can scale to a large simulation over many years. The method in this article offers a substantial step forward in building integrated visualization and behavioral simulation systems for use in community visioning, planning, and policy analysis. We demonstrate our method on several real cases using a 200 GB database for a 16,300 km2 area surrounding Seattle.

  20. The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye

    NASA Astrophysics Data System (ADS)

    Krumina, Gunta; Ozolinsh, Maris; Ikaunieks, Gatis

    2008-09-01

    In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminant coloured stimuli (white symbols on a yellow background, grey symbols on blue, green or red background). Thus isoluminant tests had colour contrast only but had no luminance contrast. Visual acuity evaluated with the standard method and colour tests were studied for subjects with good visual acuity, if necessary using the best vision correction. The same was performed for subjects with defocused eye and with true amblyopia. Defocus was realized with optical lenses placed in front of the normal eye. The obtained results applying the isoluminant colour charts revealed worsening of the visual acuity comparing with the visual acuity estimated with a standard high contrast method (black symbols on a white background).

  1. Coupled binary embedding for large-scale image retrieval.

    PubMed

    Zheng, Liang; Wang, Shengjin; Tian, Qi

    2014-08-01

    Visual matching is a crucial step in image retrieval based on the bag-of-words (BoW) model. In the baseline method, two keypoints are considered as a matching pair if their SIFT descriptors are quantized to the same visual word. However, the SIFT visual word has two limitations. First, it loses most of its discriminative power during quantization. Second, SIFT only describes the local texture feature. Both drawbacks impair the discriminative power of the BoW model and lead to false positive matches. To tackle this problem, this paper proposes to embed multiple binary features at indexing level. To model correlation between features, a multi-IDF scheme is introduced, through which different binary features are coupled into the inverted file. We show that matching verification methods based on binary features, such as Hamming embedding, can be effectively incorporated in our framework. As an extension, we explore the fusion of binary color feature into image retrieval. The joint integration of the SIFT visual word and binary features greatly enhances the precision of visual matching, reducing the impact of false positive matches. Our method is evaluated through extensive experiments on four benchmark datasets (Ukbench, Holidays, DupImage, and MIR Flickr 1M). We show that our method significantly improves the baseline approach. In addition, large-scale experiments indicate that the proposed method requires acceptable memory usage and query time compared with other approaches. Further, when global color feature is integrated, our method yields competitive performance with the state-of-the-arts.

  2. Objective measurement of bread crumb texture

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Coles, Graeme D.

    1995-01-01

    Evaluation of bread crumb texture plays an important role in judging bread quality. This paper discusses the application of image analysis methods to the objective measurement of the visual texture of bread crumb. The application of Fast Fourier Transform and mathematical morphology methods have been discussed by the authors in their previous work, and a commercial bread texture measurement system has been developed. Based on the nature of bread crumb texture, we compare the advantages and disadvantages of the two methods, and a third method based on features derived directly from statistics of edge density in local windows of the bread image. The analysis of various methods and experimental results provides an insight into the characteristics of the bread texture image and interconnection between texture measurement algorithms. The usefulness of the application of general stochastic process modelling of texture is thus revealed; it leads to more reliable and accurate evaluation of bread crumb texture. During the development of these methods, we also gained useful insights into how subjective judges form opinions about bread visual texture. These are discussed here.

  3. Efficacy of vision restoration therapy after optic neuritis (VISION study): study protocol for a randomized controlled trial.

    PubMed

    Schinzel, Johann; Schwarzlose, Lina; Dietze, Holger; Bartusch, Karolina; Weiss, Susanne; Ohlraun, Stephanie; Paul, Friedemann; Dörr, Jan

    2012-06-28

    Optic neuritis is a frequent manifestation of multiple sclerosis. Visual deficits range from a minor impairment of visual functions through to complete loss of vision. Although many patients recover almost completely, roughly 35% of patients remain visually impaired for years, and therapeutic options for those patients hardly exist. Vision restoration therapy is a software-based visual training program that has been shown to improve visual deficits after pre- and postchiasmatic injury. The aim of this pilot study is to evaluate whether residual visual deficits after past or recent optic neuritis can be reduced by means of vision restoration therapy. A randomized, controlled, patient- and observer-blinded clinical pilot study (VISION study) was designed to evaluate the efficacy of vision restoration therapy in optic neuritis patients. Eighty patients with a residual visual deficit after optic neuritis (visual acuity ≤0.7 and/or scotoma) will be stratified according to the time of optic neuritis onset (manifestation more than 12 months ago (40 patients, fixed deficit) versus manifestation 2 to 6 months ago (40 patients, recent optic neuritis)), and randomized into vision restoration therapy arm or saccadic training arm (control intervention). Patients will be instructed to complete a computer-based visual training for approximately 30 minutes each day for a period of 6 months. Patients and evaluators remain blinded to the treatment allocation throughout the study. All endpoints will be analyzed and P-values < 0.05 will be considered statistically significant. The primary outcome parameter will be the expansion of the visual field after 3 and 6 months of treatment as determined by static visual field perimetry and high resolution perimetry. Secondary outcome variables will include visual acuity at both low and high contrast, glare contrast sensitivity, visually evoked potentials, optical coherence tomography and other functional tests of the visual system, alertness, health-related quality of life, fatigue, and depression. If vision restoration therapy is shown to improve visual function after optic neuritis, this method might be a first therapeutic option for patients with incomplete recovery from optic neuritis. NCT01274702.

  4. Image quality evaluation of full reference algorithm

    NASA Astrophysics Data System (ADS)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  5. Direct Behavior Rating: An Evaluation of Time-Series Interpretations as Consequential Validity

    ERIC Educational Resources Information Center

    Christ, Theodore J.; Nelson, Peter M.; Van Norman, Ethan R.; Chafouleas, Sandra M.; Riley-Tillman, T. Chris

    2014-01-01

    Direct Behavior Rating (DBR) is a repeatable and efficient method of behavior assessment that is used to document teacher perceptions of student behavior in the classroom. Time-series data can be graphically plotted and visually analyzed to evaluate patterns of behavior or intervention effects. This study evaluated the decision accuracy of novice…

  6. Stereo photos for evaluating jack pine slash fuels.

    Treesearch

    Richard W. Blank

    1982-01-01

    Describes a quick, visual method for estimating jack pine logging residue and other fuels. The method uses a series of large color photographs and stereo pairs as well as data sheets that detail size classes and loadings of the logging slash and other fuels.

  7. Evaluation of a method for heat transfer measurements and thermal visualization using a composite of a heater element and liquid crystals. [thermal performance of turbine blade cooling configurations

    NASA Technical Reports Server (NTRS)

    Hippensteele, S. A.; Russell, L. M.; Stepka, F. S.

    1981-01-01

    Commercially available elements of a composite consisting of a plastic sheet coated with liquid crystal, another sheet with a thin layer of a conducting material (gold or carbon), and copper bus bar strips were evaluated and found to provide a simple, convenient, accurate, and low-cost measuring device for use in heat transfer research. The particular feature of the composite is its ability to obtain local heat transfer coefficients and isotherm patterns that provide visual evaluation of the thermal performances of turbine blade cooling configurations. Examples of the use of the composite are presented.

  8. Remote Sensing of Martian Terrain Hazards via Visually Salient Feature Detection

    NASA Astrophysics Data System (ADS)

    Al-Milli, S.; Shaukat, A.; Spiteri, C.; Gao, Y.

    2014-04-01

    The main objective of the FASTER remote sensing system is the detection of rocks on planetary surfaces by employing models that can efficiently characterise rocks in terms of semantic descriptions. The proposed technique abates some of the algorithmic limitations of existing methods with no training requirements, lower computational complexity and greater robustness towards visual tracking applications over long-distance planetary terrains. Visual saliency models inspired from biological systems help to identify important regions (such as rocks) in the visual scene. Surface rocks are therefore completely described in terms of their local or global conspicuity pop-out characteristics. These local and global pop-out cues are (but not limited to); colour, depth, orientation, curvature, size, luminance intensity, shape, topology etc. The currently applied methods follow a purely bottom-up strategy of visual attention for selection of conspicuous regions in the visual scene without any topdown control. Furthermore the choice of models used (tested and evaluated) are relatively fast among the state-of-the-art and have very low computational load. Quantitative evaluation of these state-ofthe- art models was carried out using benchmark datasets including the Surrey Space Centre Lab Testbed, Pangu generated images, RAL Space SEEKER and CNES Mars Yard datasets. The analysis indicates that models based on visually salient information in the frequency domain (SRA, SDSR, PQFT) are the best performing ones for detecting rocks in an extra-terrestrial setting. In particular the SRA model seems to be the most optimum of the lot especially that it requires the least computational time while keeping errors competitively low. The salient objects extracted using these models can then be merged with the Digital Elevation Models (DEMs) generated from the same navigation cameras in order to be fused to the navigation map thus giving a clear indication of the rock locations.

  9. Co-brand strategy of evaluation of visual images in furniture design: Jimmy S.P.A. and STRAUSS as examples

    NASA Astrophysics Data System (ADS)

    Chen, Tien-Li; Pan, Fang-Ming; Tsai, Jen-Hui

    2013-03-01

    This study aimed to investigate the correlation of the image associated by the design Co-Brand (Jimmy S.P.A. and STRAUSS) and the impression perceived by subject of viewers. Visual images were used to examine the merit of the evaluation. The best result is provided using an object as an appropriate evaluation method. There are a lot of factors which influence to evaluation of a design. This study is limited to distinguish the appearance from Jimmy's picture books transform furniture and so on. Co-Brand of Jimmy S.P.A. and STRAUSS is not easy because there are not from the same cultural, and industry background and applying different marketing strategy, it is a way to combine the two brands by designing, used questionnaire of SD (Semantic differential evaluation) evaluation method to test out the perception of viewers, the objective of this study is to investigate and appraised the Co-Brands use by of the image in furniture from patrons. SD evaluation result showed, if design cannot understand the perception image of Jimmy S.P.A and STRAUSS with viewers mind, furniture design also can't transmit feeling with design.

  10. Accuracy and efficiency of computer-aided anatomical analysis using 3D visualization software based on semi-automated and automated segmentations.

    PubMed

    An, Gao; Hong, Li; Zhou, Xiao-Bing; Yang, Qiong; Li, Mei-Qing; Tang, Xiang-Yang

    2017-03-01

    We investigated and compared the functionality of two 3D visualization software provided by a CT vendor and a third-party vendor, respectively. Using surgical anatomical measurement as baseline, we evaluated the accuracy of 3D visualization and verified their utility in computer-aided anatomical analysis. The study cohort consisted of 50 adult cadavers fixed with the classical formaldehyde method. The computer-aided anatomical analysis was based on CT images (in DICOM format) acquired by helical scan with contrast enhancement, using a CT vendor provided 3D visualization workstation (Syngo) and a third-party 3D visualization software (Mimics) that was installed on a PC. Automated and semi-automated segmentations were utilized in the 3D visualization workstation and software, respectively. The functionality and efficiency of automated and semi-automated segmentation methods were compared. Using surgical anatomical measurement as a baseline, the accuracy of 3D visualization based on automated and semi-automated segmentations was quantitatively compared. In semi-automated segmentation, the Mimics 3D visualization software outperformed the Syngo 3D visualization workstation. No significant difference was observed in anatomical data measurement by the Syngo 3D visualization workstation and the Mimics 3D visualization software (P>0.05). Both the Syngo 3D visualization workstation provided by a CT vendor and the Mimics 3D visualization software by a third-party vendor possessed the needed functionality, efficiency and accuracy for computer-aided anatomical analysis. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. Using false colors to protect visual privacy of sensitive content

    NASA Astrophysics Data System (ADS)

    Ćiftçi, Serdar; Korshunov, Pavel; Akyüz, Ahmet O.; Ebrahimi, Touradj

    2015-03-01

    Many privacy protection tools have been proposed for preserving privacy. Tools for protection of visual privacy available today lack either all or some of the important properties that are expected from such tools. Therefore, in this paper, we propose a simple yet effective method for privacy protection based on false color visualization, which maps color palette of an image into a different color palette, possibly after a compressive point transformation of the original pixel data, distorting the details of the original image. This method does not require any prior face detection or other sensitive regions detection and, hence, unlike typical privacy protection methods, it is less sensitive to inaccurate computer vision algorithms. It is also secure as the look-up tables can be encrypted, reversible as table look-ups can be inverted, flexible as it is independent of format or encoding, adjustable as the final result can be computed by interpolating the false color image with the original using different degrees of interpolation, less distracting as it does not create visually unpleasant artifacts, and selective as it preserves better semantic structure of the input. Four different color scales and four different compression functions, one which the proposed method relies, are evaluated via objective (three face recognition algorithms) and subjective (50 human subjects in an online-based study) assessments using faces from FERET public dataset. The evaluations demonstrate that DEF and RBS color scales lead to the strongest privacy protection, while compression functions add little to the strength of privacy protection. Statistical analysis also shows that recognition algorithms and human subjects perceive the proposed protection similarly

  12. Fundus Autofluorescence Imaging of the White Dot Syndromes

    PubMed Central

    Yeh, Steven; Forooghian, Farzin; Wong, Wai T.; Faia, Lisa J.; Cukras, Catherine; Lew, Julie C.; Wroblewski, Keith; Weichel, Eric D.; Meyerle, Catherine B.; Sen, Hatice Nida; Chew, Emily Y.; Nussenblatt, Robert B.

    2011-01-01

    Objective To characterize the fundus autofluorescence (FAF) findings in patients with white dot syndromes (WDSs). Methods Patients with WDSs underwent ophthalmic examination, fundus photography, fluorescein angiography, and FAF imaging. Patients were categorized as having no, minimal, or predominant foveal hypoautofluorescence. The severity of visual impairment was then correlated with the degree of foveal hypoautofluorescence. Results Fifty-five eyes of 28 patients with WDSs were evaluated. Visual acuities ranged from 20/12.5 to hand motions. Diagnoses included serpiginous choroidopathy (5 patients), birdshot retinochoroidopathy (10), multifocal choroiditis (8), relentless placoid chorioretinitis (1), presumed tuberculosis-associated serpiginouslike choroidopathy (1), acute posterior multifocal placoid pigment epitheliopathy (1), and acute zonal occult outer retinopathy (2). In active serpiginous choroidopathy, notable hyperautofluorescence in active disease distinguished it from the variegated FAF features of tuberculosis-associated serpiginouslike choroidopathy. The percentage of patients with visual acuity impairment of less than 20/40 differed among eyes with no, minimal, and predominant foveal hypoautofluorescence (P<.001). Patients with predominant foveal hypoautofluorescence demonstrated worse visual acuity than those with minimal or no foveal hypoautofluorescence (both P<.001). Conclusions Fundus autofluorescence imaging is useful in the evaluation of the WDS. Visual acuity impairment is correlated with foveal hypoautofluorescence. Further studies are needed to evaluate the precise role of FAF imaging in the WDSs. PMID:20065216

  13. Local spatio-temporal analysis in vision systems

    NASA Astrophysics Data System (ADS)

    Geisler, Wilson S.; Bovik, Alan; Cormack, Lawrence; Ghosh, Joydeep; Gildeen, David

    1994-07-01

    The aims of this project are the following: (1) develop a physiologically and psychophysically based model of low-level human visual processing (a key component of which are local frequency coding mechanisms); (2) develop image models and image-processing methods based upon local frequency coding; (3) develop algorithms for performing certain complex visual tasks based upon local frequency representations, (4) develop models of human performance in certain complex tasks based upon our understanding of low-level processing; and (5) develop a computational testbed for implementing, evaluating and visualizing the proposed models and algorithms, using a massively parallel computer. Progress has been substantial on all aims. The highlights include the following: (1) completion of a number of psychophysical and physiological experiments revealing new, systematic and exciting properties of the primate (human and monkey) visual system; (2) further development of image models that can accurately represent the local frequency structure in complex images; (3) near completion in the construction of the Texas Active Vision Testbed; (4) development and testing of several new computer vision algorithms dealing with shape-from-texture, shape-from-stereo, and depth-from-focus; (5) implementation and evaluation of several new models of human visual performance; and (6) evaluation, purchase and installation of a MasPar parallel computer.

  14. Qualitative evaluation of water displacement in simulated analytical breaststroke movements.

    PubMed

    Martens, Jonas; Daly, Daniel

    2012-05-01

    One purpose of evaluating a swimmer is to establish the individualized optimal technique. A swimmer's particular body structure and the resulting movement pattern will cause the surrounding water to react in differing ways. Consequently, an assessment method based on flow visualization was developed complimentary to movement analysis and body structure quantification. A fluorescent dye was used to make the water displaced by the body visible on video. To examine the hypothesis on the propulsive mechanisms applied in breaststroke swimming, we analyzed the movements of the surrounding water during 4 analytical breaststroke movements using the flow visualization technique.

  15. Evaluation of Blalock-Taussig shunts in newborns: value of oblique MRI planes.

    PubMed

    Kastler, B; Livolsi, A; Germain, P; Zöllner, G; Dietemann, J L

    1991-01-01

    Eight infants with systemic-pulmonary Blalock-Taussig shunts were evaluated by spin-echo ECG-gated MRI. Contrary to Echocardiography, MRI using coronal oblique projections successfully visualized all palliative shunts entirely in one single plane (including one carried out on a right aberrant subclavian artery). MRI allowed assessment of size, course and patency of the shunt, including pulmonary and subclavian insertion. The proximal portion of the pulmonary and subclavian arteries were also visualized. We conclude that MRI with axial scans completed by coronal oblique planes is a promising, non invasive method for imaging the anatomical features of Blalock-Taussig shunts.

  16. Evaluation of visual and computer-based CT analysis for the identification of functional patterns of obstruction and restriction in hypersensitivity pneumonitis.

    PubMed

    Jacob, Joseph; Bartholmai, Brian J; Brun, Anne Laure; Egashira, Ryoko; Rajagopalan, Srinivasan; Karwoski, Ronald; Kouranos, Vasileios; Kokosi, Maria; Hansell, David M; Wells, Athol U

    2017-11-01

    To determine whether computer-based quantification (CALIPER software) is superior to visual computed tomography (CT) scoring in the identification of CT patterns indicative of restrictive and obstructive functional indices in hypersensitivity pneumonitis (HP). A total of 135 consecutive HP patients had CT parenchymal patterns evaluated quantitatively by both visual scoring and CALIPER. Results were evaluated against: forced vital capacity (FVC), total lung capacity (TLC), diffusing capacity for carbon monoxide (DL CO ) and a composite physiological index (CPI) to identify which CT scoring method better correlated with functional indices. CALIPER-derived scores of total interstitial lung disease extent correlated more strongly than visual scores: FVC (CALIPER R = 0.73, visual R = 0.51); DL CO (CALIPER R = 0.61, visual R = 0.48); and CPI (CALIPER R = 0·70, visual R = 0·55). The CT variable that correlated most strongly with restrictive functional indices was CALIPER pulmonary vessel volume (PVV): FVC R = 0.75, DL CO R = 0.68 and CPI R = 0.76. Ground-glass opacity quantified by CALIPER alone demonstrated strong associations with restrictive functional indices: CALIPER FVC R = 0.65; DL CO R = 0.59; CPI R = 0.64; and visual = not significant. Decreased attenuation lung quantified by CALIPER was a better morphological measure of obstructive lung disease than equivalent visual scores as judged by relationships with TLC (CALIPER R = 0.63 and visual R = 0.12). All results were maintained on multivariate analysis. CALIPER improved on visual scoring in HP as judged by restrictive and obstructive functional correlations. Decreased attenuation regions of the lung quantified by CALIPER demonstrated better linkages to obstructive lung physiology than visually quantified CT scores. A novel CALIPER variable, the PVV, demonstrated the strongest linkages with restrictive functional indices and could represent a new automated index of disease severity in HP. © 2017 Asian Pacific Society of Respirology.

  17. Extensions to the visual predictive check to facilitate model performance evaluation.

    PubMed

    Post, Teun M; Freijer, Jan I; Ploeger, Bart A; Danhof, Meindert

    2008-04-01

    The Visual Predictive Check (VPC) is a valuable and supportive instrument for evaluating model performance. However in its most commonly applied form, the method largely depends on a subjective comparison of the distribution of the simulated data with the observed data, without explicitly quantifying and relating the information in both. In recent adaptations to the VPC this drawback is taken into consideration by presenting the observed and predicted data as percentiles. In addition, in some of these adaptations the uncertainty in the predictions is represented visually. However, it is not assessed whether the expected random distribution of the observations around the predicted median trend is realised in relation to the number of observations. Moreover the influence of and the information residing in missing data at each time point is not taken into consideration. Therefore, in this investigation the VPC is extended with two methods to support a less subjective and thereby more adequate evaluation of model performance: (i) the Quantified Visual Predictive Check (QVPC) and (ii) the Bootstrap Visual Predictive Check (BVPC). The QVPC presents the distribution of the observations as a percentage, thus regardless the density of the data, above and below the predicted median at each time point, while also visualising the percentage of unavailable data. The BVPC weighs the predicted median against the 5th, 50th and 95th percentiles resulting from a bootstrap of the observed data median at each time point, while accounting for the number and the theoretical position of unavailable data. The proposed extensions to the VPC are illustrated by a pharmacokinetic simulation example and applied to a pharmacodynamic disease progression example.

  18. Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads.

    PubMed

    Sliker, Levin J; Kern, Madalyn D; Schoen, Jonathan A; Rentschler, Mark E

    2012-10-01

    The state-of-the-art technology for gastrointestinal (GI) tract exploration is a capsule endoscope (CE). Capsule endoscopes are pill-sized devices that provide visual feedback of the GI tract as they move passively through the patient. These passive devices could benefit from a mobility system enabling maneuverability and controllability. Potential benefits of a tethered robotic capsule endoscope (tRCE) include faster travel speeds, reaction force generation for biopsy, and decreased capsule retention. In this work, a tethered CE is developed with an active locomotion system for mobility within a collapsed lumen. Micro-patterned polydimethylsiloxane (PDMS) treads are implemented onto a custom capsule housing as a mobility method. The tRCE housing contains a direct current (DC) motor and gear train to drive the treads, a video camera for visual feedback, and two light sources (infrared and visible) for illumination. The device was placed within the insufflated abdomen of a live anesthetized pig to evaluate mobility performance on a planar tissue surface, as well as within the cecum to evaluate mobility performance in a collapsed lumen. The tRCE was capable of forward and reverse mobility for both planar and collapsed lumen tissue environments. Also, using an onboard visual system, the tRCE was capable of demonstrating visual feedback within an insufflated, anesthetized porcine abdomen. Proof-of-concept in vivo tRCE mobility using micro-patterned PDMS treads was shown. This suggests that a similar method could be implemented in future smaller, faster, and untethered RCEs.

  19. How accurate are interpretations of curriculum-based measurement progress monitoring data? Visual analysis versus decision rules.

    PubMed

    Van Norman, Ethan R; Christ, Theodore J

    2016-10-01

    Curriculum based measurement of oral reading (CBM-R) is used to monitor the effects of academic interventions for individual students. Decisions to continue, modify, or terminate these interventions are made by interpreting time series CBM-R data. Such interpretation is founded upon visual analysis or the application of decision rules. The purpose of this study was to compare the accuracy of visual analysis and decision rules. Visual analysts interpreted 108 CBM-R progress monitoring graphs one of three ways: (a) without graphic aids, (b) with a goal line, or (c) with a goal line and a trend line. Graphs differed along three dimensions, including trend magnitude, variability of observations, and duration of data collection. Automated trend line and data point decision rules were also applied to each graph. Inferential analyses permitted the estimation of the probability of a correct decision (i.e., the student is improving - continue the intervention, or the student is not improving - discontinue the intervention) for each evaluation method as a function of trend magnitude, variability of observations, and duration of data collection. All evaluation methods performed better when students made adequate progress. Visual analysis and decision rules performed similarly when observations were less variable. Results suggest that educators should collect data for more than six weeks, take steps to control measurement error, and visually analyze graphs when data are variable. Implications for practice and research are discussed. Copyright © 2016 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  20. Evaluation of two methods for quantifying passeriform lice

    PubMed Central

    Koop, Jennifer A. H.; Clayton, Dale H.

    2013-01-01

    Two methods commonly used to quantify ectoparasites on live birds are visual examination and dust-ruffling. Visual examination provides an estimate of ectoparasite abundance based on an observer’s timed inspection of various body regions on a bird. Dust-ruffling involves application of insecticidal powder to feathers that are then ruffled to dislodge ectoparasites onto a collection surface where they can then be counted. Despite the common use of these methods in the field, the proportion of actual ectoparasites they account for has only been tested with Rock Pigeons (Columba livia), a relatively large-bodied species (238–302 g) with dense plumage. We tested the accuracy of the two methods using European Starlings (Sturnus vulgaris; ~75 g). We first quantified the number of lice (Brueelia nebulosa) on starlings using visual examination, followed immediately by dust-ruffling. Birds were then euthanized and the proportion of lice accounted for by each method was compared to the total number of lice on each bird as determined with a body-washing method. Visual examination and dust-ruffling each accounted for a relatively small proportion of total lice (14% and 16%, respectively), but both were still significant predictors of abundance. The number of lice observed by visual examination accounted for 68% of the variation in total abundance. Similarly, the number of lice recovered by dust-ruffling accounted for 72% of the variation in total abundance. Our results show that both methods can be used to reliably quantify the abundance of lice on European Starlings and other similar-sized passerines. PMID:24039328

  1. Using Importance-Performance Analysis To Evaluate Teaching Effectiveness.

    ERIC Educational Resources Information Center

    Attarian, Aram

    This paper introduces Importance-Performance (IP) analysis as a method to evaluate teaching effectiveness in a university outdoor program. Originally developed for use in the field of marketing, IP analysis is simple and easy to administer, and provides the instructor with a visual representation of what teaching attributes are important, how…

  2. AN EXPERIMENTAL EVALUATION OF AUDIO-VISUAL METHODS--CHANGING ATTITUDES TOWARD EDUCATION.

    ERIC Educational Resources Information Center

    LOWELL, EDGAR L.; AND OTHERS

    AUDIOVISUAL PROGRAMS FOR PARENTS OF DEAF CHILDREN WERE DEVELOPED AND EVALUATED. EIGHTEEN SOUND FILMS AND ACCOMPANYING RECORDS PRESENTED INFORMATION ON HEARING, LIPREADING AND SPEECH, AND ATTEMPTED TO CHANGE PARENTAL ATTITUDES TOWARD CHILDREN AND SPOUSES. TWO VERSIONS OF THE FILMS AND RECORDS WERE NARRATED BY (1) "STARS" WHO WERE…

  3. Spectral analysis method and sample generation for real time visualization of speech

    NASA Astrophysics Data System (ADS)

    Hobohm, Klaus

    A method for translating speech signals into optical models, characterized by high sound discrimination and learnability and designed to provide to deaf persons a feedback towards control of their way of speaking, is presented. Important properties of speech production and perception processes and organs involved in these mechanisms are recalled in order to define requirements for speech visualization. It is established that the spectral representation of time, frequency and amplitude resolution of hearing must be fair and continuous variations of acoustic parameters of speech signal must be depicted by a continuous variation of images. A color table was developed for dynamic illustration and sonograms were generated with five spectral analysis methods such as Fourier transformations and linear prediction coding. For evaluating sonogram quality, test persons had to recognize consonant/vocal/consonant words and an optimized analysis method was achieved with a fast Fourier transformation and a postprocessor. A hardware concept of a real time speech visualization system, based on multiprocessor technology in a personal computer, is presented.

  4. Hazardous sign detection for safety applications in traffic monitoring

    NASA Astrophysics Data System (ADS)

    Benesova, Wanda; Kottman, Michal; Sidla, Oliver

    2012-01-01

    The transportation of hazardous goods in public streets systems can pose severe safety threats in case of accidents. One of the solutions for these problems is an automatic detection and registration of vehicles which are marked with dangerous goods signs. We present a prototype system which can detect a trained set of signs in high resolution images under real-world conditions. This paper compares two different methods for the detection: bag of visual words (BoW) procedure and our approach presented as pairs of visual words with Hough voting. The results of an extended series of experiments are provided in this paper. The experiments show that the size of visual vocabulary is crucial and can significantly affect the recognition success rate. Different code-book sizes have been evaluated for this detection task. The best result of the first method BoW was 67% successfully recognized hazardous signs, whereas the second method proposed in this paper - pairs of visual words and Hough voting - reached 94% of correctly detected signs. The experiments are designed to verify the usability of the two proposed approaches in a real-world scenario.

  5. Multi-country real-life experience of anti-vascular endothelial growth factor therapy for wet age-related macular degeneration

    PubMed Central

    Holz, Frank G; Tadayoni, Ramin; Beatty, Stephen; Berger, Alan; Cereda, Matteo G; Cortez, Rafael; Hoyng, Carel B; Hykin, Philip; Staurenghi, Giovanni; Heldner, Stephanie; Bogumil, Timon; Heah, Theresa; Sivaprasad, Sobha

    2015-01-01

    Background/aims Real-life anti-vascular endothelial growth factor (VEGF) therapy use in patients with wet age-related macular degeneration (wAMD) was assessed in a retrospective, observational study in Canada, France, Germany, Ireland, Italy, the Netherlands, UK and Venezuela. Methods Medical records of patients with wAMD, who started ranibizumab treatment between 1 January 2009 and 31 August 2009, were evaluated. Data were collected until the end of treatment and/or monitoring or until 31 August 2011. Results 2227 patients who received ≥1 anti-VEGF injection with a baseline visual acuity assessment and ≥1 postbaseline visual acuity assessment for the treated eye were evaluated. Visual acuity improved until about day 120; thereafter, visual acuity gains were not maintained. Mean change in visual acuity score from baseline to years 1 and 2 was +2.4 and +0.6 letters, respectively. Patients received a mean of 5.0 and 2.2 injections in the first and second year, respectively. There were substantial differences in visual outcomes and injection frequency between countries. More frequent visits and injections were associated with greater improvements in visual acuity. Conclusions In clinical practice, fewer injections are administered than in clinical trials. Anti-VEGF treatment resulted in an initial improvement in visual acuity; however, this was not maintained over time. Trial registration number NCT01447043. PMID:25193672

  6. Working Memory and Speech Recognition in Noise under Ecologically Relevant Listening Conditions: Effects of Visual Cues and Noise Type among Adults with Hearing Loss

    ERIC Educational Resources Information Center

    Miller, Christi W.; Stewart, Erin K.; Wu, Yu-Hsiang; Bishop, Christopher; Bentler, Ruth A.; Tremblay, Kelly

    2017-01-01

    Purpose: This study evaluated the relationship between working memory (WM) and speech recognition in noise with different noise types as well as in the presence of visual cues. Method: Seventy-six adults with bilateral, mild to moderately severe sensorineural hearing loss (mean age: 69 years) participated. Using a cross-sectional design, 2…

  7. Quantification of myocardial fibrosis by digital image analysis and interactive stereology

    PubMed Central

    2014-01-01

    Background Cardiac fibrosis disrupts the normal myocardial structure and has a direct impact on heart function and survival. Despite already available digital methods, the pathologist’s visual score is still widely considered as ground truth and used as a primary method in histomorphometric evaluations. The aim of this study was to compare the accuracy of digital image analysis tools and the pathologist’s visual scoring for evaluating fibrosis in human myocardial biopsies, based on reference data obtained by point counting performed on the same images. Methods Endomyocardial biopsy material from 38 patients diagnosed with inflammatory dilated cardiomyopathy was used. The extent of total cardiac fibrosis was assessed by image analysis on Masson’s trichrome-stained tissue specimens using automated Colocalization and Genie software, by Stereology grid count and manually by Pathologist’s visual score. Results A total of 116 slides were analyzed. The mean results obtained by the Colocalization software (13.72 ± 12.24%) were closest to the reference value of stereology (RVS), while the Genie software and Pathologist score gave a slight underestimation. RVS values correlated strongly with values obtained using the Colocalization and Genie (r > 0.9, p < 0.001) software as well as the pathologist visual score. Differences in fibrosis quantification by Colocalization and RVS were statistically insignificant. However, significant bias was found in the results obtained by using Genie versus RVS and pathologist score versus RVS with mean difference values of: -1.61% and 2.24%. Bland-Altman plots showed a bidirectional bias dependent on the magnitude of the measurement: Colocalization software overestimated the area fraction of fibrosis in the lower end, and underestimated in the higher end of the RVS values. Meanwhile, Genie software as well as the pathologist score showed more uniform results throughout the values, with a slight underestimation in the mid-range for both. Conclusion Both applied digital image analysis methods revealed almost perfect correlation with the criterion standard obtained by stereology grid count and, in terms of accuracy, outperformed the pathologist’s visual score. Genie algorithm proved to be the method of choice with the only drawback of a slight underestimation bias, which is considered acceptable for both clinical and research evaluations. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/9857909611227193 PMID:24912374

  8. Thioesters for the in vitro evaluation of agents to image brain cholinesterases.

    PubMed

    Macdonald, Ian R; Jollymore, Courtney T; Reid, G Andrew; Pottie, Ian R; Martin, Earl; Darvesh, Sultan

    2013-06-01

    Cholinesterases are associated with pathology characteristic of conditions such as Alzheimer's disease and are therefore, considered targets for neuroimaging. Ester derivatives of N-methylpiperidinol are promising potential imaging agents; however, methodology is lacking for evaluating these compounds in vitro. Here, we report the synthesis and evaluation of a series of N-methylpiperidinyl thioesters, possessing comparable properties to their corresponding esters, which can be directly evaluated for cholinesterase kinetics and histochemical distribution in human brain tissue. N-methylpiperidinyl esters and thioesters were synthesized and they demonstrated comparable cholinesterase kinetics. Furthermore, thioesters were capable, using histochemical method, to visualize cholinesterase activity in human brain tissue. N-methylpiperidinyl thioesters can be rapidly evaluated for cholinesterase kinetics and visualization of enzyme distribution in brain tissue which may facilitate development of cholinesterase imaging agents for application to conditions such as Alzheimer's disease.

  9. Integrated Analysis and Visualization of Group Differences in Structural and Functional Brain Connectivity: Applications in Typical Ageing and Schizophrenia.

    PubMed

    Langen, Carolyn D; White, Tonya; Ikram, M Arfan; Vernooij, Meike W; Niessen, Wiro J

    2015-01-01

    Structural and functional brain connectivity are increasingly used to identify and analyze group differences in studies of brain disease. This study presents methods to analyze uni- and bi-modal brain connectivity and evaluate their ability to identify differences. Novel visualizations of significantly different connections comparing multiple metrics are presented. On the global level, "bi-modal comparison plots" show the distribution of uni- and bi-modal group differences and the relationship between structure and function. Differences between brain lobes are visualized using "worm plots". Group differences in connections are examined with an existing visualization, the "connectogram". These visualizations were evaluated in two proof-of-concept studies: (1) middle-aged versus elderly subjects; and (2) patients with schizophrenia versus controls. Each included two measures derived from diffusion weighted images and two from functional magnetic resonance images. The structural measures were minimum cost path between two anatomical regions according to the "Statistical Analysis of Minimum cost path based Structural Connectivity" method and the average fractional anisotropy along the fiber. The functional measures were Pearson's correlation and partial correlation of mean regional time series. The relationship between structure and function was similar in both studies. Uni-modal group differences varied greatly between connectivity types. Group differences were identified in both studies globally, within brain lobes and between regions. In the aging study, minimum cost path was highly effective in identifying group differences on all levels; fractional anisotropy and mean correlation showed smaller differences on the brain lobe and regional levels. In the schizophrenia study, minimum cost path and fractional anisotropy showed differences on the global level and within brain lobes; mean correlation showed small differences on the lobe level. Only fractional anisotropy and mean correlation showed regional differences. The presented visualizations were helpful in comparing and evaluating connectivity measures on multiple levels in both studies.

  10. A method for enhancing gunshot residue patterns on dark and multicolored fabrics compared with the modified Griess test.

    PubMed

    Bailey, James A; Casanova, Ruby S; Bufkin, Kim

    2006-07-01

    In using infrared or infrared-enhanced photography to examine gunshot residue (GSR) on dark-colored clothing, the GSR particles are microscopically examined directly on the fabric followed by the modified Griess test (MGT) for nitrites. In conducting the MGT, the GSR is transferred to treated photographic paper for visualization. A positive reaction yields an orange color on specially treated photographic paper. The examiner also evaluates the size of the powder pattern based on the distribution of nitrite reaction sites or density. A false-positive reaction can occur using the MGT due to contaminants or dyes that produce an orange cloud reaction as well. A method for enhancing visualization of the pattern produced by burned and partially unburned powder is by treatment of the fabric with a solution of sodium hypochlorite. In order to evaluate the results of sodium hypochlorite treatment for GSR visualization, the MGT was used as a reference pattern. Enhancing GSR patterns on dark or multicolored clothing was performed by treating the fabric with an application of 5.25% solution of sodium hypochlorite. Bleaching the dyes in the fabric enhances visualization of the GSR pattern by eliminating the background color. Some dyes are not affected by sodium hypochlorite; therefore, bleaching may not enhance the GSR patterns in some fabrics. Sodium hypochlorite provides the investigator with a method for enhancing GSR patterns directly on the fabric. However, this study is not intended to act as a substitute for the MGT or Sodium Rhodizonate test.

  11. Anomaly Detection in Nanofibrous Materials by CNN-Based Self-Similarity

    PubMed Central

    Schettini, Raimondo

    2018-01-01

    Automatic detection and localization of anomalies in nanofibrous materials help to reduce the cost of the production process and the time of the post-production visual inspection process. Amongst all the monitoring methods, those exploiting Scanning Electron Microscope (SEM) imaging are the most effective. In this paper, we propose a region-based method for the detection and localization of anomalies in SEM images, based on Convolutional Neural Networks (CNNs) and self-similarity. The method evaluates the degree of abnormality of each subregion of an image under consideration by computing a CNN-based visual similarity with respect to a dictionary of anomaly-free subregions belonging to a training set. The proposed method outperforms the state of the art. PMID:29329268

  12. Concurrent evaluation of visual, cytological and HPV testing as screening methods for the early detection of cervical neoplasia in Mumbai, India.

    PubMed

    Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R

    2005-03-01

    Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.

  13. Performance enhancement for audio-visual speaker identification using dynamic facial muscle model.

    PubMed

    Asadpour, Vahid; Towhidkhah, Farzad; Homayounpour, Mohammad Mehdi

    2006-10-01

    Science of human identification using physiological characteristics or biometry has been of great concern in security systems. However, robust multimodal identification systems based on audio-visual information has not been thoroughly investigated yet. Therefore, the aim of this work to propose a model-based feature extraction method which employs physiological characteristics of facial muscles producing lip movements. This approach adopts the intrinsic properties of muscles such as viscosity, elasticity, and mass which are extracted from the dynamic lip model. These parameters are exclusively dependent on the neuro-muscular properties of speaker; consequently, imitation of valid speakers could be reduced to a large extent. These parameters are applied to a hidden Markov model (HMM) audio-visual identification system. In this work, a combination of audio and video features has been employed by adopting a multistream pseudo-synchronized HMM training method. Noise robust audio features such as Mel-frequency cepstral coefficients (MFCC), spectral subtraction (SS), and relative spectra perceptual linear prediction (J-RASTA-PLP) have been used to evaluate the performance of the multimodal system once efficient audio feature extraction methods have been utilized. The superior performance of the proposed system is demonstrated on a large multispeaker database of continuously spoken digits, along with a sentence that is phonetically rich. To evaluate the robustness of algorithms, some experiments were performed on genetically identical twins. Furthermore, changes in speaker voice were simulated with drug inhalation tests. In 3 dB signal to noise ratio (SNR), the dynamic muscle model improved the identification rate of the audio-visual system from 91 to 98%. Results on identical twins revealed that there was an apparent improvement on the performance for the dynamic muscle model-based system, in which the identification rate of the audio-visual system was enhanced from 87 to 96%.

  14. Safety reliability evaluation when vehicles turn right from urban major roads onto minor ones based on driver's visual perception.

    PubMed

    Yu, Bo; Chen, Yuren; Wang, Ruiyun; Dong, Yongjie

    2016-10-01

    Turning right has a significant impact on urban road traffic safety. Driving into the curve inappropriately or with improper turning speed often leads to a series of potential accidents and hidden dangers. For a long time, the design speed at intersections has been used to determine the physical radius of curbs and channelization, and drivers are expected to drive in accordance with the design speed. However, a large number of real vehicle tests show that for the road without an exclusive right-turn lane, there is not a good correlation between the physical radius of curbs and the turning right speeds. In this paper, shape parameters of the driver's visual lane model are put forward and they have relatively high correlations with right-turn speeds. Hence, an evaluation method about safety reliability of turning right from urban major roads onto minor ones based on driver's visual perception is proposed. For existing roads, the evaluation object could be real driving videos; for those under construction roads, the evaluation object could be visual scenes obtained from a driving simulation device. Findings in this research will make a contribution to the optimization of right-turn design at intersections and lead to the development of auxiliary driving technology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Multi-scale image segmentation method with visual saliency constraints and its application

    NASA Astrophysics Data System (ADS)

    Chen, Yan; Yu, Jie; Sun, Kaimin

    2018-03-01

    Object-based image analysis method has many advantages over pixel-based methods, so it is one of the current research hotspots. It is very important to get the image objects by multi-scale image segmentation in order to carry out object-based image analysis. The current popular image segmentation methods mainly share the bottom-up segmentation principle, which is simple to realize and the object boundaries obtained are accurate. However, the macro statistical characteristics of the image areas are difficult to be taken into account, and fragmented segmentation (or over-segmentation) results are difficult to avoid. In addition, when it comes to information extraction, target recognition and other applications, image targets are not equally important, i.e., some specific targets or target groups with particular features worth more attention than the others. To avoid the problem of over-segmentation and highlight the targets of interest, this paper proposes a multi-scale image segmentation method with visually saliency graph constraints. Visual saliency theory and the typical feature extraction method are adopted to obtain the visual saliency information, especially the macroscopic information to be analyzed. The visual saliency information is used as a distribution map of homogeneity weight, where each pixel is given a weight. This weight acts as one of the merging constraints in the multi- scale image segmentation. As a result, pixels that macroscopically belong to the same object but are locally different can be more likely assigned to one same object. In addition, due to the constraint of visual saliency model, the constraint ability over local-macroscopic characteristics can be well controlled during the segmentation process based on different objects. These controls will improve the completeness of visually saliency areas in the segmentation results while diluting the controlling effect for non- saliency background areas. Experiments show that this method works better for texture image segmentation than traditional multi-scale image segmentation methods, and can enable us to give priority control to the saliency objects of interest. This method has been used in image quality evaluation, scattered residential area extraction, sparse forest extraction and other applications to verify its validation. All applications showed good results.

  16. Combining Semantic and Lexical Methods for Mapping MedDRA to VCM Icons.

    PubMed

    Lamy, Jean-Baptiste; Tsopra, Rosy

    2018-01-01

    VCM (Visualization of Concept in Medicine) is an iconic language that represents medical concepts, such as disorders, by icons. VCM has a formal semantics described by an ontology. The icons can be used in medical software for providing a visual summary or enriching texts. However, the use of VCM icons in user interfaces requires to map standard medical terminologies to VCM. Here, we present a method combining semantic and lexical approaches for mapping MedDRA to VCM. The method takes advantage of the hierarchical relations in MedDRA. It also analyzes the groups of lemmas in the term's labels, and relies on a manual mapping of these groups to the concepts in the VCM ontology. We evaluate the method on 50 terms. Finally, we discuss the method and suggest perspectives.

  17. Validity of Eye Movement Methods and Indices for Capturing Semantic (Associative) Priming Effects

    ERIC Educational Resources Information Center

    Odekar, Anshula; Hallowell, Brooke; Kruse, Hans; Moates, Danny; Lee, Chao-Yang

    2009-01-01

    Purpose: The purpose of this investigation was to evaluate the usefulness of eye movement methods and indices as a tool for studying priming effects by verifying whether eye movement indices capture semantic (associative) priming effects in a visual cross-format (written word to semantically related picture) priming paradigm. Method: In the…

  18. A replicated field intervention study evaluating the impact of a highly adjustable chair and office ergonomics training on visual symptoms☆

    PubMed Central

    Menéndez, Cammie Chaumont; Amick, Benjamin C.; Robertson, Michelle; Bazzani, Lianna; DeRango, Kelly; Rooney, Ted; Moore, Anne

    2016-01-01

    Objective Examine the effects of two office ergonomics interventions in reducing visual symptoms at a private sector worksite. Methods A quasi-experimental study design evaluated the effects of a highly adjustable chair with office ergonomics training intervention (CWT group) and the training only (TO group) compared with no intervention (CO group). Data collection occurred 2 and 1 month(s) pre-intervention and 2, 6 and 12 months post-intervention. During each data collection period, a work environment and health questionnaire (covariates) and daily health diary (outcomes) were completed. Multilevel statistical models tested hypotheses. Results Both the training only intervention (p < 0.001) and the chair with training intervention (p = 0.01) reduced visual symptoms after 12 months. Conclusion The office ergonomics training alone and coupled with a highly adjustable chair reduced visual symptoms. In replicating results from a public sector worksite at a private sector worksite the external validity of the interventions is strengthened, thus broadening its generalizability. PMID:22030069

  19. Filtering Based Adaptive Visual Odometry Sensor Framework Robust to Blurred Images

    PubMed Central

    Zhao, Haiying; Liu, Yong; Xie, Xiaojia; Liao, Yiyi; Liu, Xixi

    2016-01-01

    Visual odometry (VO) estimation from blurred image is a challenging problem in practical robot applications, and the blurred images will severely reduce the estimation accuracy of the VO. In this paper, we address the problem of visual odometry estimation from blurred images, and present an adaptive visual odometry estimation framework robust to blurred images. Our approach employs an objective measure of images, named small image gradient distribution (SIGD), to evaluate the blurring degree of the image, then an adaptive blurred image classification algorithm is proposed to recognize the blurred images, finally we propose an anti-blurred key-frame selection algorithm to enable the VO robust to blurred images. We also carried out varied comparable experiments to evaluate the performance of the VO algorithms with our anti-blur framework under varied blurred images, and the experimental results show that our approach can achieve superior performance comparing to the state-of-the-art methods under the condition with blurred images while not increasing too much computation cost to the original VO algorithms. PMID:27399704

  20. Automated estimation of image quality for coronary computed tomographic angiography using machine learning.

    PubMed

    Nakanishi, Rine; Sankaran, Sethuraman; Grady, Leo; Malpeso, Jenifer; Yousfi, Razik; Osawa, Kazuhiro; Ceponiene, Indre; Nazarat, Negin; Rahmani, Sina; Kissel, Kendall; Jayawardena, Eranthi; Dailing, Christopher; Zarins, Christopher; Koo, Bon-Kwon; Min, James K; Taylor, Charles A; Budoff, Matthew J

    2018-03-23

    Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

  1. Elevated audiovisual temporal interaction in patients with migraine without aura

    PubMed Central

    2014-01-01

    Background Photophobia and phonophobia are the most prominent symptoms in patients with migraine without aura. Hypersensitivity to visual stimuli can lead to greater hypersensitivity to auditory stimuli, which suggests that the interaction between visual and auditory stimuli may play an important role in the pathogenesis of migraine. However, audiovisual temporal interactions in migraine have not been well studied. Therefore, our aim was to examine auditory and visual interactions in migraine. Methods In this study, visual, auditory, and audiovisual stimuli with different temporal intervals between the visual and auditory stimuli were randomly presented to the left or right hemispace. During this time, the participants were asked to respond promptly to target stimuli. We used cumulative distribution functions to analyze the response times as a measure of audiovisual integration. Results Our results showed that audiovisual integration was significantly elevated in the migraineurs compared with the normal controls (p < 0.05); however, audiovisual suppression was weaker in the migraineurs compared with the normal controls (p < 0.05). Conclusions Our findings further objectively support the notion that migraineurs without aura are hypersensitive to external visual and auditory stimuli. Our study offers a new quantitative and objective method to evaluate hypersensitivity to audio-visual stimuli in patients with migraine. PMID:24961903

  2. Comparison of automated volumetry of the hippocampus using NeuroQuant® and visual assessment of the medial temporal lobe in Alzheimer's disease.

    PubMed

    Persson, Karin; Barca, Maria Lage; Cavallin, Lena; Brækhus, Anne; Knapskog, Anne-Brita; Selbæk, Geir; Engedal, Knut

    2017-01-01

    Background Different clinically feasible methods for evaluation of medial temporal lobe atrophy exists and are useful in diagnostic work-up of Alzheimer's disease (AD). Purpose To compare the diagnostic properties of two clinically available magnetic resonance imaging (MRI)-based methods-an automated volumetric software, NeuroQuant® (NQ) (evaluation of hippocampus volume) and the Scheltens scale (visual evaluation of medial temporal lobe atrophy [MTA])-in patients with AD dementia, and subjective and mild cognitive impairment (non-dementia). Material and Methods MRIs from 56 patients (31 AD, 25 non-dementia) were assessed with both methods. Correlations between the methods were calculated and receiver operating curve (ROC) analyses that yield area under the curve (AUC) statistics were conducted. Results High correlations were found between the two MRI assessments for the total hippocampal volume measured with NQ and mean MTA score (-0.753, P < 0.001), for the right (-0.767, P < 0.001), and for the left (-0.675, P < 0.001) sides. The NQ total measure yielded somewhat higher AUC (0.88, "good") compared to the MTA mean measure (0.80, "good") in the comparison of patients with AD and non-dementia, but the accuracy was in favor of the MTA scale. Conclusion The two methods correlated highly and both methods reached equally "good" power.

  3. An Improved Image Ringing Evaluation Method with Weighted Sum of Gray Extreme Value

    NASA Astrophysics Data System (ADS)

    Yang, Ling; Meng, Yanhua; Wang, Bo; Bai, Xu

    2018-03-01

    Blind image restoration algorithm usually produces ringing more obvious at the edges. Ringing phenomenon is mainly affected by noise, species of restoration algorithm, and the impact of the blur kernel estimation during restoration. Based on the physical mechanism of ringing, a method of evaluating the ringing on blind restoration images is proposed. The method extracts the ringing image overshooting and ripple region to make the weighted statistics for the regional gradient value. According to the weights set by multiple experiments, the edge information is used to characterize the details of the edge to determine the weight, quantify the seriousness of the ring effect, and propose the evaluation method of the ringing caused by blind restoration. The experimental results show that the method can effectively evaluate the ring effect in the restoration images under different restoration algorithms and different restoration parameters. The evaluation results are consistent with the visual evaluation results.

  4. An Artificial Intelligence Tutor: A Supplementary Tool for Teaching and Practicing Braille

    ERIC Educational Resources Information Center

    McCarthy, Tessa; Rosenblum, L. Penny; Johnson, Benny G.; Dittel, Jeffrey; Kearns, Devin M.

    2016-01-01

    Introduction: This study evaluated the usability and effectiveness of an artificial intelligence Braille Tutor designed to supplement the instruction of students with visual impairments as they learned to write braille contractions. Methods: A mixed-methods design was used, which incorporated a single-subject, adapted alternating treatments design…

  5. Near Infrared Imaging as a Diagnostic Tool for Detecting Enamel Demineralization: An in vivo Study

    NASA Astrophysics Data System (ADS)

    Lucas, Seth Adam

    Background and Objectives: For decades there has been an effort to develop alternative optical methods of imaging dental decay utilizing non-ionizing radiation methods. The purpose of this in-vivo study was to demonstrate whether NIR can be used as a diagnostic tool to evaluate dental caries and to compare the sensitivity and specificity of this method with that of conventional methods, including bitewing x-rays and visual inspection. Materials and Methods: 31 test subjects (n=31) from the UCSF orthodontic clinic undergoing orthodontic treatment with planned premolar extractions were recruited. Calibrated examiners performed caries detection examinations using conventional methods: bitewing radiographs and visual inspection. These findings were compared with the results from NIR examinations: transillumination and reflectance. To confirm the results found in the two different detection methods, a gold standard was used. After teeth were extracted, polarized light microscopy and transverse microradiography were performed. Results: A total of 87 premolars were used in the study. NIR identified the occlusal lesions with a sensitivity of 71% and a specificity of 77%, whereas, the visual examination had a sensitivity of only 40% and a specifity of 39%. For interproximal lesions halfway to DEJ, specificity remained constant, but sensitivity improved to 100% for NIR and 75% for x-rays. Conclusions: The results of this preliminary study demonstrate that NIR is just as effective at detecting enamel interproximal lesions as standard dental x-rays. NIR was more effective at detecting occlusal lesions than visual examination alone. NIR shows promise as an alternative diagnostic tool to the conventional methods of x-rays and visual examination and provides a non-ionizing radiation technique.

  6. Relationship between Functional Visual Acuity and Useful Field of View in Elderly Drivers

    PubMed Central

    Negishi, Kazuno; Masui, Sachiko; Mimura, Masaru; Fujita, Yoshio; Tsubota, Kazuo

    2016-01-01

    Purpose To investigate the relationship between the functional visual acuity (FVA) and useful field of view (UFOV) in elderly drivers and assess the usefulness of the FVA test to screen driving aptitude in elderly drivers. Methods This study included 45 elderly drivers (31 men, 14 women; mean age, 68.1 years) and 30 younger drivers (26 men, 4 women; mean age, 34.2 years) who drive regularly. All participants underwent measurement of the binocular corrected distant visual acuity (CDVA), binocular corrected distant FVA (CDFVA), and Visual Field with Inhibitory Tasks Elderly Version (VFIT-EV) to measure UFOV. The tear function and cognitive status also were evaluated. Results The CDVA, the CDFVA, cognitive status, and the correct response rate (CAR) of the VFIT-EV were significantly worse in the elderly group than in the control group (P = 0.000 for all parameters). The cognitive status was correlated significantly with the CDVA (r = -0.301, P = 0.009), CDFVA (r = -0.402, P = 0.000), and the CAR of the VFIT-EV (r = 0.348, P = 0.002) in all subjects. The results of the tear function tests were not correlated with the CDVA, CDFVA, or VFIT-EV in any subjects. Stepwise regression analysis for all subjects in the elderly and control groups showed that the CDFVA predicted the CAR most significantly among the clinical factors evaluated. Conclusion The FVA test is a promising method to screen the driving aptitude, including both visual and cognitive functions, in a short time. PMID:26808364

  7. Concurrent and discriminant validity of the Star Excursion Balance Test for military personnel with lateral ankle sprain.

    PubMed

    Bastien, Maude; Moffet, Hélène; Bouyer, Laurent; Perron, Marc; Hébert, Luc J; Leblond, Jean

    2014-02-01

    The Star Excursion Balance Test (SEBT) has frequently been used to measure motor control and residual functional deficits at different stages of recovery from lateral ankle sprain (LAS) in various populations. However, the validity of the measure used to characterize performance--the maximal reach distance (MRD) measured by visual estimation--is still unknown. To evaluate the concurrent validity of the MRD in the SEBT estimated visually vs the MRD measured with a 3D motion-capture system and evaluate and compare the discriminant validity of 2 MRD-normalization methods (by height or by lower-limb length) in participants with or without LAS (n = 10 per group). There is a high concurrent validity and a good degree of accuracy between the visual estimation measurement and the MRD gold-standard measurement for both groups and under all conditions. The Cohen d ratios between groups and MANOVA products were higher when computed from MRD data normalized by height. The results support the concurrent validity of visual estimation of the MRD and the use of the SEBT to evaluate motor control. Moreover, normalization of MRD data by height appears to increase the discriminant validity of this test.

  8. Design and validation of a method for evaluation of interocular interaction.

    PubMed

    Lai, Xin Jie Angela; Alexander, Jack; Ho, Arthur; Yang, Zhikuan; He, Mingguang; Suttle, Catherine

    2012-02-01

    To design a simple viewing system allowing dichoptic masking, and to validate this system in adults and children with normal vision. A Trial Frame Apparatus (TFA) was designed to evaluate interocular interaction. This device consists of a trial frame, a 1 mm pinhole in front of the tested eye and a full or partial occluder in front of the non-tested eye. The difference in visual function in one eye between the full- and partial-occlusion conditions was termed the Interaction Index. In experiment 1, low-contrast acuity was measured in six adults using five types of partial occluder. Interaction Index was compared between these five, and the occluder showing the highest Index was used in experiment 2. In experiment 2, low-contrast acuity, contrast sensitivity, and alignment sensitivity were measured in the non-dominant eye of 45 subjects (15 older adults, 15 young adults, and 15 children), using the TFA and an existing well-validated device (shutter goggles) with full and partial occlusion of the dominant eye. These measurements were repeated on 11 subjects of each group using TFA in the partial-occlusion condition only. Repeatability of visual function measurements using TFA was assessed using the Bland-Altman method and agreement between TFA and goggles in terms of visual functions and interactions was assessed using the Bland-Altman method and t-test. In all three subject groups, the TFA showed a high level of repeatability in all visual function measurements. Contrast sensitivity was significantly poorer when measured using TFA than using goggles (p < 0.05). However, Interaction Index of all three visual functions showed acceptable agreement between TFA and goggles (p > 0.05). The TFA may provide an acceptable method for the study of some forms of dichoptic masking in populations where more complex devices (e.g., shutter goggles) cannot be used.

  9. Mechanoluminescence assisting agile optimization of processing design on surgical epiphysis plates

    NASA Astrophysics Data System (ADS)

    Terasaki, Nao; Toyomasu, Takashi; Sonohata, Motoki

    2018-04-01

    We propose a novel method for agile optimization of processing design by visualization of mechanoluminescence. To demonstrate the effect of the new method, epiphysis plates were processed to form dots (diameters: 1 and 1.5 mm) and the mechanical information was evaluated. As a result, the appearance of new strain concentration was successfully visualized on the basis of mechanoluminescence, and complex mechanical information was instinctively understood by surgeons as the designers. In addition, it was clarified by mechanoluminescence analysis that small dots do not have serious mechanical effects such as strength reduction. Such detail mechanical information evaluated on the basis of mechanoluminescence was successfully applied to the judgement of the validity of the processing design. This clearly proves the effectiveness of the new methodology using mechanoluminescence for assisting agile optimization of the processing design.

  10. Breast sentinel lymph node navigation with three-dimensional computed tomography-lymphography: a 12-year study.

    PubMed

    Yamamoto, Shigeru; Suga, Kazuyoshi; Maeda, Kazunari; Maeda, Noriko; Yoshimura, Kiyoshi; Oka, Masaaki

    2016-05-01

    To evaluate the utility of three-dimensional (3D) computed tomography (CT)-lymphography (LG) breast sentinel lymph node navigation in our institute. Between 2002 and 2013, we preoperatively identified sentinel lymph nodes (SLNs) in 576 clinically node-negative breast cancer patients with T1 and T2 breast cancer using 3D CT-LG method. SLN biopsy (SLNB) was performed in 557 of 576 patients using both the images of 3D CT-LG for guidance and the blue dye method. Using 3D CT-LG, SLNs were visualized in 569 (99%) of 576 patients. Of 569 patients, both lymphatic draining ducts and SLNs from the peritumoral and periareolar areas were visualized in 549 (96%) patients. Only SLNs without lymphatic draining ducts were visualized in 20 patients. Drainage lymphatic pathways visualized with 3D CT-LG (549 cases) were classified into four patterns: single route/single SLN (355 cases, 65%), multiple routes/single SLN (59 cases, 11%) single route/multiple SLNs (62 cases, 11%) and multiple routes/multiple SLNs (73 cases, 13%). SLNs were detected in 556 (99.8%) of 557 patients during SLNB. CT-LG is useful for preoperative visualization of SLNs and breast lymphatic draining routes. This preoperative method should contribute greatly to the easy detection of SLNs during SLNB.

  11. Visual assessment of soil structure quality in an agroextractivist system in Southeastern Amazonia

    NASA Astrophysics Data System (ADS)

    Fernanda Simões da Silva, Laura; Stuchi Boschi, Raquel; Ortega Gomes, Matheus; Cooper, Miguel

    2016-04-01

    Soil structure is considered a key factor in the functioning of soil, affecting its ability to support plant and animal life, and moderate environmental quality. Numerous methods are available to evaluate soil structure based on physical, chemical and biological indicators. Among the physical indicators, the attributes most commonly used are soil bulk density, porosity, soil resistance to penetration, tensile strength of aggregates, soil water infiltration, and available water. However, these methods are expensive and generally time costly for sampling and laboratorial procedures. Recently, evaluations using qualitative and semi-quantitative indicators of soil structure quality have gained importance. Among these methods, the method known as Visual Evaluation of Soil Structure (VESS) (Ball et al., 2007; Guimarães et al., 2011) can supply this necessity in temperate and tropical regions. The study area is located in the Piranheira Praialta Agroextrativist Settlement Project in the county of Nova Ipixuna, Pará, Brazil. Two toposequences were chosen, one under native forest and the other under pasture. Pits were opened in different landscape positions (upslope, midslope and downslope) for soil morphological, micromorphological and physical characterization. The use of the soil visual evaluation method (SVE) consisted in collecting an undisturbed soil sample of approximately 25 cm in length, 20 cm in width and 10 cm in depth. 12 soil samples were taken for each land use. The samples were manually fragmented, respecting the fracture planes between the aggregates. The SVE was done comparing the fragmented sample with a visual chart and scores were given to the soil structure. The categories that define the soil structure quality (Qe) vary from 1 to 5. Lower scores mean better soil structure. The final score calculation was done using the classification key of Ball et al. (2007) adapted by Guimarães (2011). A change in soil structure was observed between forest and pasture. The presence of layers of different depths, and size and shape of aggregates resulted in a lower Qe in the forest soils (Qe= 2,04 ±0,4), followed by the pasture (Qe= 3,09 ± 1,3). These results indicate certain degradation in the soil structure in the pasture. The variability of the soil structure in the forest samples was lower. The pasture samples presented a worse soil structure when compared to the forest, although their Qe values can be considered good.

  12. Shade matching assisted by digital photography and computer software.

    PubMed

    Schropp, Lars

    2009-04-01

    To evaluate the efficacy of digital photographs and graphic computer software for color matching compared to conventional visual matching. The shade of a tab from a shade guide (Vita 3D-Master Guide) placed in a phantom head was matched to a second guide of the same type by nine observers. This was done for twelve selected shade tabs (tests). The shade-matching procedure was performed visually in a simulated clinic environment and with digital photographs, and the time spent for both procedures was recorded. An alternative arrangement of the shade tabs was used in the digital photographs. In addition, a graphic software program was used for color analysis. Hue, chroma, and lightness values of the test tab and all tabs of the second guide were derived from the digital photographs. According to the CIE L*C*h* color system, the color differences between the test tab and tabs of the second guide were calculated. The shade guide tab that deviated least from the test tab was determined to be the match. Shade matching performance by means of graphic software was compared with the two visual methods and tested by Chi-square tests (alpha= 0.05). Eight of twelve test tabs (67%) were matched correctly by the computer software method. This was significantly better (p < 0.02) than the performance of the visual shade matching methods conducted in the simulated clinic (32% correct match) and with photographs (28% correct match). No correlation between time consumption for the visual shade matching methods and frequency of correct match was observed. Shade matching assisted by digital photographs and computer software was significantly more reliable than by conventional visual methods.

  13. Signal evaluation environment: a new method for the design of peripheral in-vehicle warning signals.

    PubMed

    Werneke, Julia; Vollrath, Mark

    2011-06-01

    An evaluation method called the Signal Evaluation Environment (SEE) was developed for use in the early stages of the design process of peripheral warning signals while driving. Accident analyses have shown that with complex driving situations such as intersections, the visual scan strategies of the driver contribute to overlooking other road users who have the right of way. Salient peripheral warning signals could disrupt these strategies and direct drivers' attention towards these road users. To select effective warning signals, the SEE was developed as a laboratory task requiring visual-cognitive processes similar to those used at intersections. For validation of the SEE, four experiments were conducted using different stimulus characteristics (size, colour contrast, shape, flashing) that influence peripheral vision. The results confirm that the SEE is able to differentiate between the selected stimulus characteristics. The SEE is a useful initial tool for designing peripheral signals, allowing quick and efficient preselection of beneficial signals.

  14. Evaluation of camouflage effectiveness using hyperspectral images

    NASA Astrophysics Data System (ADS)

    Zavvartorbati, Ahmad; Dehghani, Hamid; Rashidi, Ali Jabar

    2017-10-01

    Recent advances in camouflage engineering have made it more difficult to detect targets. Assessing the effectiveness of camouflage against different target detection methods leads to identifying the strengths and weaknesses of camouflage designs. One of the target detection methods is to analyze the content of the scene using remote sensing hyperspectral images. In the process of evaluating camouflage designs, there must be comprehensive and efficient evaluation criteria. Three parameters were considered as the main factors affecting the target detection and based on these factors, camouflage effectiveness assessment criteria were proposed. To combine the criteria in the form of a single equation, the equation used in target visual search models was employed and for determining the criteria, a model was presented based on the structure of the computational visual attention systems. Also, in software implementations on the HyMap hyperspectral image, a variety of camouflage levels were created for the real targets in the image. Assessing the camouflage levels using the proposed criteria, comparing and analyzing the results can show that the provided criteria and model are effective for the evaluation of camouflage designs using hyperspectral images.

  15. 3D cinematic rendering of the calvarium, maxillofacial structures, and skull base: preliminary observations.

    PubMed

    Rowe, Steven P; Zinreich, S James; Fishman, Elliot K

    2018-06-01

    Three-dimensional (3D) visualizations of volumetric data from CT have gained widespread clinical acceptance and are an important method for evaluating complex anatomy and pathology. Recently, cinematic rendering (CR), a new 3D visualization methodology, has become available. CR utilizes a lighting model that allows for the production of photorealistic images from isotropic voxel data. Given how new this technique is, studies to evaluate its clinical utility and any potential advantages or disadvantages relative to other 3D methods such as volume rendering have yet to be published. In this pictorial review, we provide examples of normal calvarial, maxillofacial, and skull base anatomy and pathological conditions that highlight the potential for CR images to aid in patient evaluation and treatment planning. The highly detailed images and nuanced shadowing that are intrinsic to CR are well suited to the display of the complex anatomy in this region of the body. We look forward to studies with CR that will ascertain the ultimate value of this methodology to evaluate calvarium, maxillofacial, and skull base morphology as well as other complex anatomic structures.

  16. Relationship Between Rates of Binocular Visual Field Loss and Vision-Related Quality of Life in Glaucoma

    PubMed Central

    Lisboa, Renato; Chun, Yeoun Sook; Zangwill, Linda M.; Weinreb, Robert N.; Rosen, Peter N.; Liebmann, Jeffrey M.; Girkin, Christopher A.; Medeiros, Felipe A.

    2013-01-01

    Objective To evaluate the relationship between binocular rates of visual field change and vision-related quality of life (VRQOL) in glaucoma. Methods The study included 796 eyes of 398 participants that had diagnosed or suspected glaucoma followed for an average of 7.3 ± 2.0 years. Subjects were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES). VRQOL was evaluated using the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) at the last follow-up visit. Integrated binocular visual fields (BVF) were calculated from the monocular fields of each patient. Linear regression of mean deviation (MD) values was used to evaluate rates of visual field change during the follow-up period. Logistic regression models were used to investigate the relationship between abnormal VRQOL and rates of visual field change, while adjusting for potentially confounding socio-economic and demographic variables. Results Thirty-two patients (8.0%) had abnormal VRQOL as determined by the results of the NEI VFQ-25 questionnaire. Subjects with abnormal VRQOL had significantly faster rates of BVF change than those with normal VRQOL (−0.18 db/year vs. −0.06 dB/year, respectively; P < 0.001). Rates of BVF change were significantly associated with abnormality in VRQOL (OR = 1.31 per 0.1dB/year faster; P = 0.038), after adjustment for confounding variables. Conclusions Patients with faster rates of BVF change were at higher risk of reporting abnormal VRQOL. Assessment of rates of BVF change may provide useful information in determining risk of functional impairment in glaucoma. PMID:23450425

  17. A Method for the Evaluation of Thousands of Automated 3D Stem Cell Segmentations

    PubMed Central

    Bajcsy, Peter; Simon, Mylene; Florczyk, Stephen; Simon, Carl G.; Juba, Derek; Brady, Mary

    2016-01-01

    There is no segmentation method that performs perfectly with any data set in comparison to human segmentation. Evaluation procedures for segmentation algorithms become critical for their selection. The problems associated with segmentation performance evaluations and visual verification of segmentation results are exaggerated when dealing with thousands of 3D image volumes because of the amount of computation and manual inputs needed. We address the problem of evaluating 3D segmentation performance when segmentation is applied to thousands of confocal microscopy images (z-stacks). Our approach is to incorporate experimental imaging and geometrical criteria, and map them into computationally efficient segmentation algorithms that can be applied to a very large number of z-stacks. This is an alternative approach to considering existing segmentation methods and evaluating most state-of-the-art algorithms. We designed a methodology for 3D segmentation performance characterization that consists of design, evaluation and verification steps. The characterization integrates manual inputs from projected surrogate “ground truth” of statistically representative samples and from visual inspection into the evaluation. The novelty of the methodology lies in (1) designing candidate segmentation algorithms by mapping imaging and geometrical criteria into algorithmic steps, and constructing plausible segmentation algorithms with respect to the order of algorithmic steps and their parameters, (2) evaluating segmentation accuracy using samples drawn from probability distribution estimates of candidate segmentations, and (3) minimizing human labor needed to create surrogate “truth” by approximating z-stack segmentations with 2D contours from three orthogonal z-stack projections and by developing visual verification tools. We demonstrate the methodology by applying it to a dataset of 1253 mesenchymal stem cells. The cells reside on 10 different types of biomaterial scaffolds, and are stained for actin and nucleus yielding 128 460 image frames (on average 125 cells/scaffold × 10 scaffold types × 2 stains × 51 frames/cell). After constructing and evaluating six candidates of 3D segmentation algorithms, the most accurate 3D segmentation algorithm achieved an average precision of 0.82 and an accuracy of 0.84 as measured by the Dice similarity index where values greater than 0.7 indicate a good spatial overlap. A probability of segmentation success was 0.85 based on visual verification, and a computation time was 42.3 h to process all z-stacks. While the most accurate segmentation technique was 4.2 times slower than the second most accurate algorithm, it consumed on average 9.65 times less memory per z-stack segmentation. PMID:26268699

  18. EnsembleGraph: Interactive Visual Analysis of Spatial-Temporal Behavior for Ensemble Simulation Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, Qingya; Guo, Hanqi; Che, Limei

    We present a novel visualization framework—EnsembleGraph— for analyzing ensemble simulation data, in order to help scientists understand behavior similarities between ensemble members over space and time. A graph-based representation is used to visualize individual spatiotemporal regions with similar behaviors, which are extracted by hierarchical clustering algorithms. A user interface with multiple-linked views is provided, which enables users to explore, locate, and compare regions that have similar behaviors between and then users can investigate and analyze the selected regions in detail. The driving application of this paper is the studies on regional emission influences over tropospheric ozone, which is based onmore » ensemble simulations conducted with different anthropogenic emission absences using the MOZART-4 (model of ozone and related tracers, version 4) model. We demonstrate the effectiveness of our method by visualizing the MOZART-4 ensemble simulation data and evaluating the relative regional emission influences on tropospheric ozone concentrations. Positive feedbacks from domain experts and two case studies prove efficiency of our method.« less

  19. Quantifying the quality of medical x-ray images: An evaluation based on normal anatomy for lumbar spine and chest radiography

    NASA Astrophysics Data System (ADS)

    Tingberg, Anders Martin

    Optimisation in diagnostic radiology requires accurate methods for determination of patient absorbed dose and clinical image quality. Simple methods for evaluation of clinical image quality are at present scarce and this project aims at developing such methods. Two methods are used and further developed; fulfillment of image criteria (IC) and visual grading analysis (VGA). Clinical image quality descriptors are defined based on these two methods: image criteria score (ICS) and visual grading analysis score (VGAS), respectively. For both methods the basis is the Image Criteria of the ``European Guidelines on Quality Criteria for Diagnostic Radiographic Images''. Both methods have proved to be useful for evaluation of clinical image quality. The two methods complement each other: IC is an absolute method, which means that the quality of images of different patients and produced with different radiographic techniques can be compared with each other. The separating power of IC is, however, weaker than that of VGA. VGA is the best method for comparing images produced with different radiographic techniques and has strong separating power, but the results are relative, since the quality of an image is compared to the quality of a reference image. The usefulness of the two methods has been verified by comparing the results from both of them with results from a generally accepted method for evaluation of clinical image quality, receiver operating characteristics (ROC). The results of the comparison between the two methods based on visibility of anatomical structures and the method based on detection of pathological structures (free-response forced error) indicate that the former two methods can be used for evaluation of clinical image quality as efficiently as the method based on ROC. More studies are, however, needed for us to be able to draw a general conclusion, including studies of other organs, using other radiographic techniques, etc. The results of the experimental evaluation of clinical image quality are compared with physical quantities calculated with a theoretical model based on a voxel phantom, and correlations are found. The results demonstrate that the computer model can be a useful toot in planning further experimental studies.

  20. 20 CFR 416.985 - How we evaluate other visual impairments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false How we evaluate other visual impairments. 416... evaluate other visual impairments. If you are not blind as defined in the law, we will evaluate a visual impairment the same as we evaluate other impairments in determining disability. Although you will not qualify...

  1. Gradient-based interpolation method for division-of-focal-plane polarimeters.

    PubMed

    Gao, Shengkui; Gruev, Viktor

    2013-01-14

    Recent advancements in nanotechnology and nanofabrication have allowed for the emergence of the division-of-focal-plane (DoFP) polarization imaging sensors. These sensors capture polarization properties of the optical field at every imaging frame. However, the DoFP polarization imaging sensors suffer from large registration error as well as reduced spatial-resolution output. These drawbacks can be improved by applying proper image interpolation methods for the reconstruction of the polarization results. In this paper, we present a new gradient-based interpolation method for DoFP polarimeters. The performance of the proposed interpolation method is evaluated against several previously published interpolation methods by using visual examples and root mean square error (RMSE) comparison. We found that the proposed gradient-based interpolation method can achieve better visual results while maintaining a lower RMSE than other interpolation methods under various dynamic ranges of a scene ranging from dim to bright conditions.

  2. Visual homing with a pan-tilt based stereo camera

    NASA Astrophysics Data System (ADS)

    Nirmal, Paramesh; Lyons, Damian M.

    2013-01-01

    Visual homing is a navigation method based on comparing a stored image of the goal location and the current image (current view) to determine how to navigate to the goal location. It is theorized that insects, such as ants and bees, employ visual homing methods to return to their nest. Visual homing has been applied to autonomous robot platforms using two main approaches: holistic and feature-based. Both methods aim at determining distance and direction to the goal location. Navigational algorithms using Scale Invariant Feature Transforms (SIFT) have gained great popularity in the recent years due to the robustness of the feature operator. Churchill and Vardy have developed a visual homing method using scale change information (Homing in Scale Space, HiSS) from SIFT. HiSS uses SIFT feature scale change information to determine distance between the robot and the goal location. Since the scale component is discrete with a small range of values, the result is a rough measurement with limited accuracy. We have developed a method that uses stereo data, resulting in better homing performance. Our approach utilizes a pan-tilt based stereo camera, which is used to build composite wide-field images. We use the wide-field images combined with stereo-data obtained from the stereo camera to extend the keypoint vector described in to include a new parameter, depth (z). Using this info, our algorithm determines the distance and orientation from the robot to the goal location. We compare our method with HiSS in a set of indoor trials using a Pioneer 3-AT robot equipped with a BumbleBee2 stereo camera. We evaluate the performance of both methods using a set of performance measures described in this paper.

  3. Detection of wood failure by image processing method: influence of algorithm, adhesive and wood species

    Treesearch

    Lanying Lin; Sheng He; Feng Fu; Xiping Wang

    2015-01-01

    Wood failure percentage (WFP) is an important index for evaluating the bond strength of plywood. Currently, the method used for detecting WFP is visual inspection, which lacks efficiency. In order to improve it, image processing methods are applied to wood failure detection. The present study used thresholding and K-means clustering algorithms in wood failure detection...

  4. Perceived direction of gravity and the body-axis during static whole body roll-tilt in healthy subjects.

    PubMed

    Tamura, Atsushi; Wada, Yoshiro; Inui, Takuo; Shiotani, Akihiro

    2017-10-01

    We used the subjective visual vertical (SVV) and two different subjective visual body axis (SVBA) methods to quantify roll-tilt perception under gravity, and investigated the characteristics of these methods during static roll-tilt. In addition, we independently developed a compact device to facilitate evaluation of SVBA in different gravitational environments. Ten male volunteers participated in this study. We created a roll-tilt environment using a flight simulator in a dark room. The cockpit of the simulator was tilted leftward or rightward (-30°, -20°, -10°, 0°, 10°, 20° and 30°) in each randomly ordered trial. We quantified roll-tilt perception such that the experiment was conducted under 21 different conditions per participant. We found no significant differences among the SVV error and the two types of SVBA error. The SVV and the SVBA methods may be useful for evaluating subjective roll-tilt perception.

  5. Visualization assisted by parallel processing

    NASA Astrophysics Data System (ADS)

    Lange, B.; Rey, H.; Vasques, X.; Puech, W.; Rodriguez, N.

    2011-01-01

    This paper discusses the experimental results of our visualization model for data extracted from sensors. The objective of this paper is to find a computationally efficient method to produce a real time rendering visualization for a large amount of data. We develop visualization method to monitor temperature variance of a data center. Sensors are placed on three layers and do not cover all the room. We use particle paradigm to interpolate data sensors. Particles model the "space" of the room. In this work we use a partition of the particle set, using two mathematical methods: Delaunay triangulation and Voronoý cells. Avis and Bhattacharya present these two algorithms in. Particles provide information on the room temperature at different coordinates over time. To locate and update particles data we define a computational cost function. To solve this function in an efficient way, we use a client server paradigm. Server computes data and client display this data on different kind of hardware. This paper is organized as follows. The first part presents related algorithm used to visualize large flow of data. The second part presents different platforms and methods used, which was evaluated in order to determine the better solution for the task proposed. The benchmark use the computational cost of our algorithm that formed based on located particles compared to sensors and on update of particles value. The benchmark was done on a personal computer using CPU, multi core programming, GPU programming and hybrid GPU/CPU. GPU programming method is growing in the research field; this method allows getting a real time rendering instates of a precompute rendering. For improving our results, we compute our algorithm on a High Performance Computing (HPC), this benchmark was used to improve multi-core method. HPC is commonly used in data visualization (astronomy, physic, etc) for improving the rendering and getting real-time.

  6. A comparative study of qualitative and quantitative methods for the assessment of adhesive remnant after bracket debonding.

    PubMed

    Cehreli, S Burcak; Polat-Ozsoy, Omur; Sar, Cagla; Cubukcu, H Evren; Cehreli, Zafer C

    2012-04-01

    The amount of the residual adhesive after bracket debonding is frequently assessed in a qualitative manner, utilizing the adhesive remnant index (ARI). This study aimed to investigate whether quantitative assessment of the adhesive remnant yields more precise results compared to qualitative methods utilizing the 4- and 5-point ARI scales. Twenty debonded brackets were selected. Evaluation and scoring of the adhesive remnant on bracket bases were made consecutively using: 1. qualitative assessment (visual scoring) and 2. quantitative measurement (image analysis) on digital photographs. Image analysis was made on scanning electron micrographs (SEM) and high-precision elemental maps of the adhesive remnant as determined by energy dispersed X-ray spectrometry. Evaluations were made in accordance with the original 4-point and the modified 5-point ARI scales. Intra-class correlation coefficients (ICCs) were calculated, and the data were evaluated using Friedman test followed by Wilcoxon signed ranks test with Bonferroni correction. ICC statistics indicated high levels of agreement for qualitative visual scoring among examiners. The 4-point ARI scale was compliant with the SEM assessments but indicated significantly less adhesive remnant compared to the results of quantitative elemental mapping. When the 5-point scale was used, both quantitative techniques yielded similar results with those obtained qualitatively. These results indicate that qualitative visual scoring using the ARI is capable of generating similar results with those assessed by quantitative image analysis techniques. In particular, visual scoring with the 5-point ARI scale can yield similar results with both the SEM analysis and elemental mapping.

  7. Is Mc Leod's Patent Pending Naturoptic Method for Restoring Healthy Vision Easy and Verifiable?

    NASA Astrophysics Data System (ADS)

    Niemi, Paul; McLeod, David; McLeod, Roger

    2006-10-01

    RDM asserts that he and people he has trained can assign visual tasks from standard vision assessment charts, or better replacements, proceeding through incremental changes and such rapid improvements that healthy vision can be restored. Mc Leod predicts that in visual tasks with pupil diameter changes, wavelengths change proportionally. A longer, quasimonochromatic wavelength interval is coincident with foveal cones, and rods. A shorter, partially overlapping interval separately aligns with extrafoveal cones. Wavelengths follow the Airy disk radius formula. Niemi can evaluate if it is true that visual health merely requires triggering and facilitating the demands of possibly overridden feedback signals. The method and process are designed so that potential Naturopathic and other select graduate students should be able to self-fund their higher- level educations from preferential franchising arrangements of earnings while they are in certain programs.

  8. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  9. Effect of higher frequency on the classification of steady-state visual evoked potentials

    NASA Astrophysics Data System (ADS)

    Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan

    2016-02-01

    Objective. Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. Approach. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. Main results. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. Significance. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.

  10. Effect of higher frequency on the classification of steady-state visual evoked potentials.

    PubMed

    Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan

    2016-02-01

    Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.

  11. A novel visual saliency analysis model based on dynamic multiple feature combination strategy

    NASA Astrophysics Data System (ADS)

    Lv, Jing; Ye, Qi; Lv, Wen; Zhang, Libao

    2017-06-01

    The human visual system can quickly focus on a small number of salient objects. This process was known as visual saliency analysis and these salient objects are called focus of attention (FOA). The visual saliency analysis mechanism can be used to extract the salient regions and analyze saliency of object in an image, which is time-saving and can avoid unnecessary costs of computing resources. In this paper, a novel visual saliency analysis model based on dynamic multiple feature combination strategy is introduced. In the proposed model, we first generate multi-scale feature maps of intensity, color and orientation features using Gaussian pyramids and the center-surround difference. Then, we evaluate the contribution of all feature maps to the saliency map according to the area of salient regions and their average intensity, and attach different weights to different features according to their importance. Finally, we choose the largest salient region generated by the region growing method to perform the evaluation. Experimental results show that the proposed model cannot only achieve higher accuracy in saliency map computation compared with other traditional saliency analysis models, but also extract salient regions with arbitrary shapes, which is of great value for the image analysis and understanding.

  12. Visual- and Vestibular-Autonomic Influence on Short-Term Cardiovascular Regulatory Mechanisms

    NASA Technical Reports Server (NTRS)

    Mullen, Thomas J.; Ramsdell, Craig D.

    1999-01-01

    This synergy project was a one-year effort conducted cooperatively by members of the NSBRI Cardiovascular Alterations and Neurovestibular Adaptation Teams in collaboration with NASA Johnson Space Center (JSC) colleagues. The objective of this study was to evaluate visual autonomic interactions on short-term cardiovascular regulatory mechanisms. Based on established visual-vestibular and vestibular-autonomic shared neural pathways, we hypothesized that visually induced changes in orientation will trigger autonomic cardiovascular reflexes. A second objective was to compare baroreflex changes during postural changes as measured with the new Cardiovascular System Identification (CSI) technique with those measured using a neck barocuff. While the neck barocuff stimulates only the carotid baroreceptors, CSI provides a measure of overall baroreflex responsiveness. This study involved a repeated measures design with 16 healthy human subjects (8 M, 8 F) to examine cardiovascular regulatory responses during actual and virtual head-upright tilts. Baroreflex sensitivity was first evaluated with subjects in supine and upright positions during actual tilt-table testing using both neck barocuff and CSI methods. The responses to actual tilts during this first session were then compared to responses during visually induced tilt and/or rotation obtained during a second session.

  13. B-1 AFT Nacelle Flow Visualization Study

    NASA Technical Reports Server (NTRS)

    Celniker, Robert

    1975-01-01

    A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.

  14. Volumetric three-dimensional intravascular ultrasound visualization using shape-based nonlinear interpolation

    PubMed Central

    2013-01-01

    Background Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in terms of complex spatial distribution of arterial morphology and acoustic backscatter information. Conventional 3D IVUS techniques provide sub-optimal visualization of arterial morphology or lack acoustic information concerning arterial structure due in part to low quality of image data and the use of pixel-based IVUS image reconstruction algorithms. In the present study, we describe a novel volumetric 3D IVUS reconstruction algorithm to utilize IVUS signal data and a shape-based nonlinear interpolation. Methods We developed an algorithm to convert a series of IVUS signal data into a fully volumetric 3D visualization. Intermediary slices between original 2D IVUS slices were generated utilizing the natural cubic spline interpolation to consider the nonlinearity of both vascular structure geometry and acoustic backscatter in the arterial wall. We evaluated differences in image quality between the conventional pixel-based interpolation and the shape-based nonlinear interpolation methods using both virtual vascular phantom data and in vivo IVUS data of a porcine femoral artery. Volumetric 3D IVUS images of the arterial segment reconstructed using the two interpolation methods were compared. Results In vitro validation and in vivo comparative studies with the conventional pixel-based interpolation method demonstrated more robustness of the shape-based nonlinear interpolation algorithm in determining intermediary 2D IVUS slices. Our shape-based nonlinear interpolation demonstrated improved volumetric 3D visualization of the in vivo arterial structure and more realistic acoustic backscatter distribution compared to the conventional pixel-based interpolation method. Conclusions This novel 3D IVUS visualization strategy has the potential to improve ultrasound imaging of vascular structure information, particularly atheroma determination. Improved volumetric 3D visualization with accurate acoustic backscatter information can help with ultrasound molecular imaging of atheroma component distribution. PMID:23651569

  15. Robust Stereo Visual Odometry Using Improved RANSAC-Based Methods for Mobile Robot Localization

    PubMed Central

    Liu, Yanqing; Gu, Yuzhang; Li, Jiamao; Zhang, Xiaolin

    2017-01-01

    In this paper, we present a novel approach for stereo visual odometry with robust motion estimation that is faster and more accurate than standard RANSAC (Random Sample Consensus). Our method makes improvements in RANSAC in three aspects: first, the hypotheses are preferentially generated by sampling the input feature points on the order of ages and similarities of the features; second, the evaluation of hypotheses is performed based on the SPRT (Sequential Probability Ratio Test) that makes bad hypotheses discarded very fast without verifying all the data points; third, we aggregate the three best hypotheses to get the final estimation instead of only selecting the best hypothesis. The first two aspects improve the speed of RANSAC by generating good hypotheses and discarding bad hypotheses in advance, respectively. The last aspect improves the accuracy of motion estimation. Our method was evaluated in the KITTI (Karlsruhe Institute of Technology and Toyota Technological Institute) and the New Tsukuba dataset. Experimental results show that the proposed method achieves better results for both speed and accuracy than RANSAC. PMID:29027935

  16. Evaluation methodology for comparing memory and communication of analytic processes in visual analytics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragan, Eric D; Goodall, John R

    2014-01-01

    Provenance tools can help capture and represent the history of analytic processes. In addition to supporting analytic performance, provenance tools can be used to support memory of the process and communication of the steps to others. Objective evaluation methods are needed to evaluate how well provenance tools support analyst s memory and communication of analytic processes. In this paper, we present several methods for the evaluation of process memory, and we discuss the advantages and limitations of each. We discuss methods for determining a baseline process for comparison, and we describe various methods that can be used to elicit processmore » recall, step ordering, and time estimations. Additionally, we discuss methods for conducting quantitative and qualitative analyses of process memory. By organizing possible memory evaluation methods and providing a meta-analysis of the potential benefits and drawbacks of different approaches, this paper can inform study design and encourage objective evaluation of process memory and communication.« less

  17. Determination of Oebalus pugnax (Hemiptera: Pentatomidae) spatial pattern in rice and development of visual sampling methods and population sampling plans.

    PubMed

    Espino, L; Way, M O; Wilson, L T

    2008-02-01

    Commercial rice, Oryza sativa L., fields in southeastern Texas were sampled during 2003 and 2004, and visual samples were compared with sweep net samples. Fields were sampled at different stages of panicle development, times of day, and by different operators. Significant differences were found between perimeter and within field sweep net samples, indicating that samples taken 9 m from the field margin overestimate within field Oebalus pugnax (F.) (Hemiptera: Pentatomidae) populations. Time of day did not significantly affect the number of O. pugnax caught with the sweep net; however, there was a trend to capture more insects during morning than afternoon. For all sampling methods evaluated during this study, O. pugnax was found to have an aggregated spatial pattern at most densities. When comparing sweep net with visual sampling methods, one sweep of the "long stick" and two sweeps of the "sweep stick" correlated well with the sweep net (r2 = 0.639 and r2 = 0.815, respectively). This relationship was not affected by time of day of sampling, stage of panicle development, type of planting or operator. Relative cost-reliability, which incorporates probability of adoption, indicates the visual methods are more cost-reliable than the sweep net for sampling O.

  18. Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

    NASA Technical Reports Server (NTRS)

    Benson, Elizabeth; Cowley, Matthew; Harvill, Lauren; Rajulu. Sudhakar

    2015-01-01

    Introduction: When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. It has been shown that using a spherical coordinate system allows Anthropometry and Biomechanics Facility (ABF) personnel to increase their ability to transmit important human mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project was to use innovative analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub-projects, meant to validate and verify a new method before it was implemented in the ABF's data analysis practices. A mechanical test rig was built and tracked in 3D using an optical motion capture system. Its position and orientation were reported in both Euler and spherical reference systems. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder to include the rest of the joints of the body. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. These visualization methods will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development. Results: Initial results demonstrated that a spherical coordinate system is helpful in describing and visualizing the motion of a space suit. The system is particularly useful in describing the motion of the shoulder, where multiple degrees of freedom can lead to very complex motion paths.

  19. Visual analytics in healthcare education: exploring novel ways to analyze and represent big data in undergraduate medical education

    PubMed Central

    Nilsson, Gunnar; Zary, Nabil

    2014-01-01

    Introduction. The big data present in the medical curriculum that informs undergraduate medical education is beyond human abilities to perceive and analyze. The medical curriculum is the main tool used by teachers and directors to plan, design, and deliver teaching and assessment activities and student evaluations in medical education in a continuous effort to improve it. Big data remains largely unexploited for medical education improvement purposes. The emerging research field of visual analytics has the advantage of combining data analysis and manipulation techniques, information and knowledge representation, and human cognitive strength to perceive and recognize visual patterns. Nevertheless, there is a lack of research on the use and benefits of visual analytics in medical education. Methods. The present study is based on analyzing the data in the medical curriculum of an undergraduate medical program as it concerns teaching activities, assessment methods and learning outcomes in order to explore visual analytics as a tool for finding ways of representing big data from undergraduate medical education for improvement purposes. Cytoscape software was employed to build networks of the identified aspects and visualize them. Results. After the analysis of the curriculum data, eleven aspects were identified. Further analysis and visualization of the identified aspects with Cytoscape resulted in building an abstract model of the examined data that presented three different approaches; (i) learning outcomes and teaching methods, (ii) examination and learning outcomes, and (iii) teaching methods, learning outcomes, examination results, and gap analysis. Discussion. This study identified aspects of medical curriculum that play an important role in how medical education is conducted. The implementation of visual analytics revealed three novel ways of representing big data in the undergraduate medical education context. It appears to be a useful tool to explore such data with possible future implications on healthcare education. It also opens a new direction in medical education informatics research. PMID:25469323

  20. Visual analytics in healthcare education: exploring novel ways to analyze and represent big data in undergraduate medical education.

    PubMed

    Vaitsis, Christos; Nilsson, Gunnar; Zary, Nabil

    2014-01-01

    Introduction. The big data present in the medical curriculum that informs undergraduate medical education is beyond human abilities to perceive and analyze. The medical curriculum is the main tool used by teachers and directors to plan, design, and deliver teaching and assessment activities and student evaluations in medical education in a continuous effort to improve it. Big data remains largely unexploited for medical education improvement purposes. The emerging research field of visual analytics has the advantage of combining data analysis and manipulation techniques, information and knowledge representation, and human cognitive strength to perceive and recognize visual patterns. Nevertheless, there is a lack of research on the use and benefits of visual analytics in medical education. Methods. The present study is based on analyzing the data in the medical curriculum of an undergraduate medical program as it concerns teaching activities, assessment methods and learning outcomes in order to explore visual analytics as a tool for finding ways of representing big data from undergraduate medical education for improvement purposes. Cytoscape software was employed to build networks of the identified aspects and visualize them. Results. After the analysis of the curriculum data, eleven aspects were identified. Further analysis and visualization of the identified aspects with Cytoscape resulted in building an abstract model of the examined data that presented three different approaches; (i) learning outcomes and teaching methods, (ii) examination and learning outcomes, and (iii) teaching methods, learning outcomes, examination results, and gap analysis. Discussion. This study identified aspects of medical curriculum that play an important role in how medical education is conducted. The implementation of visual analytics revealed three novel ways of representing big data in the undergraduate medical education context. It appears to be a useful tool to explore such data with possible future implications on healthcare education. It also opens a new direction in medical education informatics research.

  1. A flow visualization study of the NCVC centrifugal blood pump.

    PubMed

    Araki, K; Taenaka, Y; Masuzawa, T; Tatsumi, E; Wakisaka, Y; Watari, M; Nakatani, T; Akagi, H; Baba, Y; Anai, H

    1994-09-01

    A compact centrifugal pump, NCVC-1, has an open-type impeller with 6 curved vanes, and it is characterized by no shaft and no seal. A tunnel is placed in the center of the impeller-rotor assembly to irrigate the back space behind the rotor. To evaluate the flow, we performed 3 visualization methods: tracer, oil film, and injection streak line method. The flow, observed by the tracer method in NCVC-1, indicated little turbulence along vanes. A volute chamber proved effective to reduce vortex formation in the outlet. Oil film pattern revealed no flow separation on vanes at 5 L/min. Washout flow behind the rotor is essential to prevent thrombus formation and was shown as inward spiral flow without any stagnation. These data suggested that a combination of visualization techniques was useful to analyze various flow conditions, and the NCVC-1 has excellent flow characteristics with little turbulence and little flow stagnation, which must be beneficial to low hemolysis and high antithrombogenicity.

  2. The development concept of Taman Aloon-Aloon Tulungagung based on visual accessibility, diversity of activities and perception of users

    NASA Astrophysics Data System (ADS)

    Sasongko, W.; Kurniasanti, R. P.; Siregar, J. P.

    2017-06-01

    Tulungagung has a public space that actively used by the community named Taman Aloon-aloon Tulungagung. The importance of research on the Development Concept of Taman Aloon-aloon Tulungagung as open public space is requiring location structuring for appeal aspects of public space in order to spread evenly and can be enjoyed by users of public space. Therefore, this study aimed to assess users’ perceptions of the attractiveness of public space by Importance Performance Analysis (IPA) method and assess the level of users’ visual accessibility by Visibility Graph Analysis (VGA) method and assess the diversity of users’ activity by Behavior Mapping method. As this study shows that the condition of the floor surface, the location of a bird cage, shade conditions of public space and location of lighting lamp become the top priority in the development concept of Taman Aloon-aloon Tulungagung. The location for the prioritized attributes are adjusted to the results of the visual accessibility level evaluation matrix and activities diversity.

  3. Criteria for assessment of bridge aesthetic and visual quality

    NASA Astrophysics Data System (ADS)

    Rozentale, I.; Paeglitis, A.

    2017-10-01

    The bridge designers should find an ideal balance between structure, economy, buildability, aesthetics, durability and harmony with industrial or natural landscape. During the last years, the society has adopted documents providing procedures for evaluation of the impact of the structural appearance on surrounding landscape. The European Landscape Convention defines the landscape as an area perceived by people, whose character is the result of the action and interaction of natural and/or human factors. The Convention indicates the methods for clear and objective assessment of the landscape’s visual qualities. The esthetical qualities of bridge structures, appearance and attraction should satisfy not only the technicians - engineers and architects, but mostly the surrounding population. Each of these groups has a different perception of esthetical qualities of structure. Many authors have used different methods and criteria for assessment of bridge aesthetics. The aim of this paper is to provide an overview of the bridge aesthetic and visual quality assessment methods and criteria.

  4. All-optical recording and stimulation of retinal neurons in vivo in retinal degeneration mice

    PubMed Central

    Strazzeri, Jennifer M.; Williams, David R.; Merigan, William H.

    2018-01-01

    Here we demonstrate the application of a method that could accelerate the development of novel therapies by allowing direct and repeatable visualization of cellular function in the living eye, to study loss of vision in animal models of retinal disease, as well as evaluate the time course of retinal function following therapeutic intervention. We use high-resolution adaptive optics scanning light ophthalmoscopy to image fluorescence from the calcium sensor GCaMP6s. In mice with photoreceptor degeneration (rd10), we measured restored visual responses in ganglion cell layer neurons expressing the red-shifted channelrhodopsin ChrimsonR over a six-week period following significant loss of visual responses. Combining a fluorescent calcium sensor, a channelrhodopsin, and adaptive optics enables all-optical stimulation and recording of retinal neurons in the living eye. Because the retina is an accessible portal to the central nervous system, our method also provides a novel non-invasive method of dissecting neuronal processing in the brain. PMID:29596518

  5. Quantification of myocardial fibrosis by digital image analysis and interactive stereology.

    PubMed

    Daunoravicius, Dainius; Besusparis, Justinas; Zurauskas, Edvardas; Laurinaviciene, Aida; Bironaite, Daiva; Pankuweit, Sabine; Plancoulaine, Benoit; Herlin, Paulette; Bogomolovas, Julius; Grabauskiene, Virginija; Laurinavicius, Arvydas

    2014-06-09

    Cardiac fibrosis disrupts the normal myocardial structure and has a direct impact on heart function and survival. Despite already available digital methods, the pathologist's visual score is still widely considered as ground truth and used as a primary method in histomorphometric evaluations. The aim of this study was to compare the accuracy of digital image analysis tools and the pathologist's visual scoring for evaluating fibrosis in human myocardial biopsies, based on reference data obtained by point counting performed on the same images. Endomyocardial biopsy material from 38 patients diagnosed with inflammatory dilated cardiomyopathy was used. The extent of total cardiac fibrosis was assessed by image analysis on Masson's trichrome-stained tissue specimens using automated Colocalization and Genie software, by Stereology grid count and manually by Pathologist's visual score. A total of 116 slides were analyzed. The mean results obtained by the Colocalization software (13.72 ± 12.24%) were closest to the reference value of stereology (RVS), while the Genie software and Pathologist score gave a slight underestimation. RVS values correlated strongly with values obtained using the Colocalization and Genie (r>0.9, p<0.001) software as well as the pathologist visual score. Differences in fibrosis quantification by Colocalization and RVS were statistically insignificant. However, significant bias was found in the results obtained by using Genie versus RVS and pathologist score versus RVS with mean difference values of: -1.61% and 2.24%. Bland-Altman plots showed a bidirectional bias dependent on the magnitude of the measurement: Colocalization software overestimated the area fraction of fibrosis in the lower end, and underestimated in the higher end of the RVS values. Meanwhile, Genie software as well as the pathologist score showed more uniform results throughout the values, with a slight underestimation in the mid-range for both. Both applied digital image analysis methods revealed almost perfect correlation with the criterion standard obtained by stereology grid count and, in terms of accuracy, outperformed the pathologist's visual score. Genie algorithm proved to be the method of choice with the only drawback of a slight underestimation bias, which is considered acceptable for both clinical and research evaluations. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/9857909611227193.

  6. Hyperspectral interventional imaging for enhanced tissue visualization and discrimination combining band selection methods.

    PubMed

    Nouri, Dorra; Lucas, Yves; Treuillet, Sylvie

    2016-12-01

    Hyperspectral imaging is an emerging technology recently introduced in medical applications inasmuch as it provides a powerful tool for noninvasive tissue characterization. In this context, a new system was designed to be easily integrated in the operating room in order to detect anatomical tissues hardly noticed by the surgeon's naked eye. Our LCTF-based spectral imaging system is operative over visible, near- and middle-infrared spectral ranges (400-1700 nm). It is dedicated to enhance critical biological tissues such as the ureter and the facial nerve. We aim to find the best three relevant bands to create a RGB image to display during the intervention with maximal contrast between the target tissue and its surroundings. A comparative study is carried out between band selection methods and band transformation methods. Combined band selection methods are proposed. All methods are compared using different evaluation criteria. Experimental results show that the proposed combined band selection methods provide the best performance with rich information, high tissue separability and short computational time. These methods yield a significant discrimination between biological tissues. We developed a hyperspectral imaging system in order to enhance some biological tissue visualization. The proposed methods provided an acceptable trade-off between the evaluation criteria especially in SWIR spectral band that outperforms the naked eye's capacities.

  7. Critical evaluation of five methods for quantifying chewing lice (Insecta: Phthiraptera).

    PubMed

    Clayton, D H; Drown, D M

    2001-12-01

    Five methods for estimating the abundance of chewing lice (Insecta: Phthiraptera) were tested. To evaluate the methods, feral pigeons (Columba livia) and 2 species of ischnoceran lice were used. The fraction of lice removed by each method was compared, and least squares linear regression was used to determine how well each method predicted total abundance. Total abundance was assessed in most cases using KOH dissolution. The 2 methods involving dead birds (body washing and post-mortem-ruffling) provided better results than 3 methods involving live birds (dust-ruffling, fumigation chambers, and visual examination). Body washing removed the largest fraction of lice (>82%) and was an extremely accurate predictor of total abundance (r2 = 0.99). Post-mortem-ruffling was also an accurate predictor of total abundance (r2 > or = 0.88), even though it removed a smaller proportion of lice (<70%) than body washing. Dust-ruffling and fumigation chambers removed even fewer lice, but were still reasonably accurate predictors of total abundance, except in the case of data sets restricted to birds with relatively few lice. Visual examination, the only method not requiring that lice be removed from the host, was an accurate predictor of louse abundance, except in the case of wing lice on lightly parasitized birds.

  8. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

    PubMed Central

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-01-01

    Objective To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2  =  0.92 versus r2  =  0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (κ  =  0.87 v κ  =  0.75, p < 0.05). Conclusion MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine. PMID:15939722

  9. A Locally Weighted Fixation Density-Based Metric for Assessing the Quality of Visual Saliency Predictions

    NASA Astrophysics Data System (ADS)

    Gide, Milind S.; Karam, Lina J.

    2016-08-01

    With the increased focus on visual attention (VA) in the last decade, a large number of computational visual saliency methods have been developed over the past few years. These models are traditionally evaluated by using performance evaluation metrics that quantify the match between predicted saliency and fixation data obtained from eye-tracking experiments on human observers. Though a considerable number of such metrics have been proposed in the literature, there are notable problems in them. In this work, we discuss shortcomings in existing metrics through illustrative examples and propose a new metric that uses local weights based on fixation density which overcomes these flaws. To compare the performance of our proposed metric at assessing the quality of saliency prediction with other existing metrics, we construct a ground-truth subjective database in which saliency maps obtained from 17 different VA models are evaluated by 16 human observers on a 5-point categorical scale in terms of their visual resemblance with corresponding ground-truth fixation density maps obtained from eye-tracking data. The metrics are evaluated by correlating metric scores with the human subjective ratings. The correlation results show that the proposed evaluation metric outperforms all other popular existing metrics. Additionally, the constructed database and corresponding subjective ratings provide an insight into which of the existing metrics and future metrics are better at estimating the quality of saliency prediction and can be used as a benchmark.

  10. Comparison of shade matching by visual observation and an intraoral dental colorimeter.

    PubMed

    Li, Q; Wang, Y N

    2007-11-01

    The purpose of this study was to compare the applicability of two shade-matching approaches: Vintage Halo shade guide (visual method) and Shofu ShadeEye NCC colorimeter (instrumental method). Twenty participants' maxillary left central incisors were evaluated. Corresponding metal ceramic crowns were fabricated with each shade-matching approach. The colour distributions (L*, a* and b*) of the middle third region of each tooth and corresponding metal ceramic crowns were spectrophotometrically assessed. The colour difference (DeltaE) and colour distributions (DeltaL*, Deltaa* and Deltab*) between the tooth and the corresponding crowns were calculated. We found that the colour differences of both groups fell within the clinical unacceptable range (DeltaE > 2.75). Regarding DeltaE and the three colour distributions, no significant difference was found, expect for a* (P < 0.01). The shade matching difficulty degree was analysed through the agreements of visual shade selection. Within easy matching cases, the instrumental method achieved better results (P = 0.041). In conclusion, it is suggested that the reliability of shade matching can be ensured by neither the colorimeter nor the visual approach. However, the colorimeter can achieve better results within easy matching cases.

  11. Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: safety and efficacy evaluation in rhesus macaques.

    PubMed

    McDannold, Nathan; Arvanitis, Costas D; Vykhodtseva, Natalia; Livingstone, Margaret S

    2012-07-15

    The blood-brain barrier (BBB) prevents entry of most drugs into the brain and is a major hurdle to the use of drugs for brain tumors and other central nervous system disorders. Work in small animals has shown that ultrasound combined with an intravenously circulating microbubble agent can temporarily permeabilize the BBB. Here, we evaluated whether this targeted drug delivery method can be applied safely, reliably, and in a controlled manner on rhesus macaques using a focused ultrasound system. We identified a clear safety window during which BBB disruption could be produced without evident tissue damage, and the acoustic pressure amplitude where the probability for BBB disruption was 50% and was found to be half of the value that would produce tissue damage. Acoustic emission measurements seem promising for predicting BBB disruption and damage. In addition, we conducted repeated BBB disruption to central visual field targets over several weeks in animals trained to conduct complex visual acuity tasks. All animals recovered from each session without behavioral deficits, visual deficits, or loss in visual acuity. Together, our findings show that BBB disruption can be reliably and repeatedly produced without evident histologic or functional damage in a clinically relevant animal model using a clinical device. These results therefore support clinical testing of this noninvasive-targeted drug delivery method.

  12. Color-coded duplex sonography for diagnosis of testicular torsion.

    PubMed

    Zoeller, G; Ringert, R H

    1991-11-01

    By color-coded duplex sonography moving structures are visualized as red or blue colors within a normal gray-scale B-mode ultrasound image. Thus, blood flow even within small vessels can be visualized clearly. Color-coded duplex sonographic examination was performed in 11 patients who presented with scrotal pain. This method proved to be reliable to differentiate between testicular torsion and testicular inflammation. By clearly demonstrating a lack of intratesticular blood flow in testicular torsion, while avoiding flow in scrotal skin vessels being misinterpreted as intratesticular blood flow, this method significantly decreases the number of patients in whom surgical evaluation is necessary to exclude testicular torsion.

  13. Regional Principal Color Based Saliency Detection

    PubMed Central

    Lou, Jing; Ren, Mingwu; Wang, Huan

    2014-01-01

    Saliency detection is widely used in many visual applications like image segmentation, object recognition and classification. In this paper, we will introduce a new method to detect salient objects in natural images. The approach is based on a regional principal color contrast modal, which incorporates low-level and medium-level visual cues. The method allows a simple computation of color features and two categories of spatial relationships to a saliency map, achieving higher F-measure rates. At the same time, we present an interpolation approach to evaluate resulting curves, and analyze parameters selection. Our method enables the effective computation of arbitrary resolution images. Experimental results on a saliency database show that our approach produces high quality saliency maps and performs favorably against ten saliency detection algorithms. PMID:25379960

  14. New approach to estimating variability in visual field data using an image processing technique.

    PubMed Central

    Crabb, D P; Edgar, D F; Fitzke, F W; McNaught, A I; Wynn, H P

    1995-01-01

    AIMS--A new framework for evaluating pointwise sensitivity variation in computerised visual field data is demonstrated. METHODS--A measure of local spatial variability (LSV) is generated using an image processing technique. Fifty five eyes from a sample of normal and glaucomatous subjects, examined on the Humphrey field analyser (HFA), were used to illustrate the method. RESULTS--Significant correlation between LSV and conventional estimates--namely, HFA pattern standard deviation and short term fluctuation, were found. CONCLUSION--LSV is not dependent on normals' reference data or repeated threshold determinations, thus potentially reducing test time. Also, the illustrated pointwise maps of LSV could provide a method for identifying areas of fluctuation commonly found in early glaucomatous field loss. PMID:7703196

  15. Deterministic object tracking using Gaussian ringlet and directional edge features

    NASA Astrophysics Data System (ADS)

    Krieger, Evan W.; Sidike, Paheding; Aspiras, Theus; Asari, Vijayan K.

    2017-10-01

    Challenges currently existing for intensity-based histogram feature tracking methods in wide area motion imagery (WAMI) data include object structural information distortions, background variations, and object scale change. These issues are caused by different pavement or ground types and from changing the sensor or altitude. All of these challenges need to be overcome in order to have a robust object tracker, while attaining a computation time appropriate for real-time processing. To achieve this, we present a novel method, Directional Ringlet Intensity Feature Transform (DRIFT), which employs Kirsch kernel filtering for edge features and a ringlet feature mapping for rotational invariance. The method also includes an automatic scale change component to obtain accurate object boundaries and improvements for lowering computation times. We evaluated the DRIFT algorithm on two challenging WAMI datasets, namely Columbus Large Image Format (CLIF) and Large Area Image Recorder (LAIR), to evaluate its robustness and efficiency. Additional evaluations on general tracking video sequences are performed using the Visual Tracker Benchmark and Visual Object Tracking 2014 databases to demonstrate the algorithms ability with additional challenges in long complex sequences including scale change. Experimental results show that the proposed approach yields competitive results compared to state-of-the-art object tracking methods on the testing datasets.

  16. Visual enhancement of unmixed multispectral imagery using adaptive smoothing

    USGS Publications Warehouse

    Lemeshewsky, G.P.; Rahman, Z.-U.; Schowengerdt, R.A.; Reichenbach, S.E.

    2004-01-01

    Adaptive smoothing (AS) has been previously proposed as a method to smooth uniform regions of an image, retain contrast edges, and enhance edge boundaries. The method is an implementation of the anisotropic diffusion process which results in a gray scale image. This paper discusses modifications to the AS method for application to multi-band data which results in a color segmented image. The process was used to visually enhance the three most distinct abundance fraction images produced by the Lagrange constraint neural network learning-based unmixing of Landsat 7 Enhanced Thematic Mapper Plus multispectral sensor data. A mutual information-based method was applied to select the three most distinct fraction images for subsequent visualization as a red, green, and blue composite. A reported image restoration technique (partial restoration) was applied to the multispectral data to reduce unmixing error, although evaluation of the performance of this technique was beyond the scope of this paper. The modified smoothing process resulted in a color segmented image with homogeneous regions separated by sharpened, coregistered multiband edges. There was improved class separation with the segmented image, which has importance to subsequent operations involving data classification.

  17. Performance Evaluation and Quality Validation System for Optical Gas Imaging Cameras that Visualize Fugitive Hydrocarbon Gas Emissions

    EPA Science Inventory

    A U.S. EPA team, consisting of the Office of Research and Development and Region 6 (Dallas) and Region 8 (Denver), deployed passive-diffusive sorbent tubes as part of a method evaluation study around one oil and natural gas production pad in both the Barnett Shale Basin in Texas ...

  18. An adaptive block-based fusion method with LUE-SSIM for multi-focus images

    NASA Astrophysics Data System (ADS)

    Zheng, Jianing; Guo, Yongcai; Huang, Yukun

    2016-09-01

    Because of the lenses' limited depth of field, digital cameras are incapable of acquiring an all-in-focus image of objects at varying distances in a scene. Multi-focus image fusion technique can effectively solve this problem. Aiming at the block-based multi-focus image fusion methods, the problem that blocking-artifacts often occurs. An Adaptive block-based fusion method based on lifting undistorted-edge structural similarity (LUE-SSIM) is put forward. In this method, image quality metrics LUE-SSIM is firstly proposed, which utilizes the characteristics of human visual system (HVS) and structural similarity (SSIM) to make the metrics consistent with the human visual perception. Particle swarm optimization(PSO) algorithm which selects LUE-SSIM as the object function is used for optimizing the block size to construct the fused image. Experimental results on LIVE image database shows that LUE-SSIM outperform SSIM on Gaussian defocus blur images quality assessment. Besides, multi-focus image fusion experiment is carried out to verify our proposed image fusion method in terms of visual and quantitative evaluation. The results show that the proposed method performs better than some other block-based methods, especially in reducing the blocking-artifact of the fused image. And our method can effectively preserve the undistorted-edge details in focus region of the source images.

  19. Intelligibility Evaluation of Pathological Speech through Multigranularity Feature Extraction and Optimization.

    PubMed

    Fang, Chunying; Li, Haifeng; Ma, Lin; Zhang, Mancai

    2017-01-01

    Pathological speech usually refers to speech distortion resulting from illness or other biological insults. The assessment of pathological speech plays an important role in assisting the experts, while automatic evaluation of speech intelligibility is difficult because it is usually nonstationary and mutational. In this paper, we carry out an independent innovation of feature extraction and reduction, and we describe a multigranularity combined feature scheme which is optimized by the hierarchical visual method. A novel method of generating feature set based on S -transform and chaotic analysis is proposed. There are BAFS (430, basic acoustics feature), local spectral characteristics MSCC (84, Mel S -transform cepstrum coefficients), and chaotic features (12). Finally, radar chart and F -score are proposed to optimize the features by the hierarchical visual fusion. The feature set could be optimized from 526 to 96 dimensions based on NKI-CCRT corpus and 104 dimensions based on SVD corpus. The experimental results denote that new features by support vector machine (SVM) have the best performance, with a recognition rate of 84.4% on NKI-CCRT corpus and 78.7% on SVD corpus. The proposed method is thus approved to be effective and reliable for pathological speech intelligibility evaluation.

  20. Methods study for the relocation of visual information in central scotoma cases

    NASA Astrophysics Data System (ADS)

    Scherlen, Anne-Catherine; Gautier, Vincent

    2005-03-01

    In this study we test the benefit on the reading performance of different ways to relocating the visual information present under the scotoma. The relocation (or unmasking) allows to compensate the loss of information and avoid the patient developing driving strategies not adapted for the reading. Eight healthy subjects were tested on a reading task, on each a central scotoma of various sizes was simulated. We then evaluate the reading speed (words/min) during three visual information relocation methods: all masked information is relocated - on both side of scotoma, - on the right of scotoma, - and only essentials letters for the word recognition too on the right of scotoma. We compare these reading speeds versus the pathological condition, ie without relocating visual information. Our results show that unmasking strategy improve the reading speed when all the visual information is unmask to the right of scotoma, this only for large scotoma. Taking account the word morphology, the perception of only certain letters outside the scotoma can be sufficient to improve the reading speed. A deepening of reading processes in the presence of a scotoma will then allows a new perspective for visual information unmasking. Multidisciplinary competences brought by engineers, ophtalmologists, linguists, clinicians would allow to optimize the reading benefit brought by the unmasking.

  1. Geovisual analytics to enhance spatial scan statistic interpretation: an analysis of U.S. cervical cancer mortality

    PubMed Central

    Chen, Jin; Roth, Robert E; Naito, Adam T; Lengerich, Eugene J; MacEachren, Alan M

    2008-01-01

    Background Kulldorff's spatial scan statistic and its software implementation – SaTScan – are widely used for detecting and evaluating geographic clusters. However, two issues make using the method and interpreting its results non-trivial: (1) the method lacks cartographic support for understanding the clusters in geographic context and (2) results from the method are sensitive to parameter choices related to cluster scaling (abbreviated as scaling parameters), but the system provides no direct support for making these choices. We employ both established and novel geovisual analytics methods to address these issues and to enhance the interpretation of SaTScan results. We demonstrate our geovisual analytics approach in a case study analysis of cervical cancer mortality in the U.S. Results We address the first issue by providing an interactive visual interface to support the interpretation of SaTScan results. Our research to address the second issue prompted a broader discussion about the sensitivity of SaTScan results to parameter choices. Sensitivity has two components: (1) the method can identify clusters that, while being statistically significant, have heterogeneous contents comprised of both high-risk and low-risk locations and (2) the method can identify clusters that are unstable in location and size as the spatial scan scaling parameter is varied. To investigate cluster result stability, we conducted multiple SaTScan runs with systematically selected parameters. The results, when scanning a large spatial dataset (e.g., U.S. data aggregated by county), demonstrate that no single spatial scan scaling value is known to be optimal to identify clusters that exist at different scales; instead, multiple scans that vary the parameters are necessary. We introduce a novel method of measuring and visualizing reliability that facilitates identification of homogeneous clusters that are stable across analysis scales. Finally, we propose a logical approach to proceed through the analysis of SaTScan results. Conclusion The geovisual analytics approach described in this manuscript facilitates the interpretation of spatial cluster detection methods by providing cartographic representation of SaTScan results and by providing visualization methods and tools that support selection of SaTScan parameters. Our methods distinguish between heterogeneous and homogeneous clusters and assess the stability of clusters across analytic scales. Method We analyzed the cervical cancer mortality data for the United States aggregated by county between 2000 and 2004. We ran SaTScan on the dataset fifty times with different parameter choices. Our geovisual analytics approach couples SaTScan with our visual analytic platform, allowing users to interactively explore and compare SaTScan results produced by different parameter choices. The Standardized Mortality Ratio and reliability scores are visualized for all the counties to identify stable, homogeneous clusters. We evaluated our analysis result by comparing it to that produced by other independent techniques including the Empirical Bayes Smoothing and Kafadar spatial smoother methods. The geovisual analytics approach introduced here is developed and implemented in our Java-based Visual Inquiry Toolkit. PMID:18992163

  2. Evaluation of algorithms for point cloud surface reconstruction through the analysis of shape parameters

    NASA Astrophysics Data System (ADS)

    Cao, Lu; Verbeek, Fons J.

    2012-03-01

    In computer graphics and visualization, reconstruction of a 3D surface from a point cloud is an important research area. As the surface contains information that can be measured, i.e. expressed in features, the application of surface reconstruction can be potentially important for application in bio-imaging. Opportunities in this application area are the motivation for this study. In the past decade, a number of algorithms for surface reconstruction have been proposed. Generally speaking, these methods can be separated into two categories: i.e., explicit representation and implicit approximation. Most of the aforementioned methods are firmly based in theory; however, so far, no analytical evaluation between these methods has been presented. The straightforward way of evaluation has been by convincing through visual inspection. Through evaluation we search for a method that can precisely preserve the surface characteristics and that is robust in the presence of noise. The outcome will be used to improve reliability in surface reconstruction of biological models. We, therefore, use an analytical approach by selecting features as surface descriptors and measure these features in varying conditions. We selected surface distance, surface area and surface curvature as three major features to compare quality of the surface created by the different algorithms. Our starting point has been ground truth values obtained from analytical shapes such as the sphere and the ellipsoid. In this paper we present four classical surface reconstruction methods from the two categories mentioned above, i.e. the Power Crust, the Robust Cocone, the Fourier-based method and the Poisson reconstruction method. The results obtained from our experiments indicate that Poisson reconstruction method performs the best in the presence of noise.

  3. Evaluation of a Public Child Eye Health Tertiary Facility for Pediatric Cataract in Southern Nigeria I: Visual Acuity Outcome

    PubMed Central

    Duke, Roseline E.; Adio, Adedayo; Oparah, Sidney K.; Odey, Friday; Eyo, Okon A.

    2016-01-01

    Purpose: A retrospective study of the outcome of congenital and developmental cataract surgery was conducted in a public child eye health tertiary facility in children <16 years of age in Southern Nigeria, as part of an evaluation. Materials and Method: Manual Small Incision Cataract Surgery with or without anterior vitrectomy was performed. The outcome measures were visual acuity (VA) and change (gain) in visual acuity. The age of the child at onset, duration of delay in presentation, ocular co-morbidity, non ocular co-morbidity, gender, and pre operative visual acuity were matched with postoperative visual acuity. A total of 66 children were studied for a period of six weeks following surgery. Results: Forty eight (72.7%) children had bilateral congenital cataracts and 18 (27.3%) children had bilateral developmental cataracts. There were 38(57.6%) males and 28 (42.4%) females in the study. Thirty Five (53%) children had good visual outcome (normal vision range 6/6/ -6/18) post-operatively. The number of children with blindness (vision <3/60) decreased from 61 (92.4%) pre-operatively to 4 (6.1%) post-operatively. Post operative complication occurred in 6.8% of cases six week after surgery. Delayed presentation had an inverse relationship with change (gain) in visual acuity (r = - 0.342; p-value = 0.005). Pre-operative visual acuity had a positive relationship with post operative change (gain) in visual acuity (r = 0.618; p-value = 0.000). Conclusion: Predictors of change in visual acuity in our study were; delayed presentation and pre-operative VA. Cataract surgery in children showed clinical benefit. PMID:27347247

  4. Are children with low vision adapted to the visual environment in classrooms of mainstream schools?

    PubMed Central

    Negiloni, Kalpa; Ramani, Krishna Kumar; Jeevitha, R; Kalva, Jayashree; Sudhir, Rachapalle Reddi

    2018-01-01

    Purpose: The study aimed to evaluate the classroom environment of children with low vision and provide recommendations to reduce visual stress, with focus on mainstream schooling. Methods: The medical records of 110 children (5–17 years) seen in low vision clinic during 1 year period (2015) at a tertiary care center in south India were extracted. The visual function levels of children were compared to the details of their classroom environment. The study evaluated and recommended the chalkboard visual task size and viewing distance required for children with mild, moderate, and severe visual impairment (VI). Results: The major causes of low vision based on the site of abnormality and etiology were retinal (80%) and hereditary (67%) conditions, respectively, in children with mild (n = 18), moderate (n = 72), and severe (n = 20) VI. Many of the children (72%) had difficulty in viewing chalkboard and common strategies used for better visibility included copying from friends (47%) and going closer to chalkboard (42%). To view the chalkboard with reduced visual stress, a child with mild VI can be seated at a maximum distance of 4.3 m from the chalkboard, with the minimum size of visual task (height of lowercase letter writing on chalkboard) recommended to be 3 cm. For 3/60–6/60 range, the maximum viewing distance with the visual task size of 4 cm is recommended to be 85 cm to 1.7 m. Conclusion: Simple modifications of the visual task size and seating arrangements can aid children with low vision with better visibility of chalkboard and reduced visual stress to manage in mainstream schools. PMID:29380777

  5. Evaluation of peripheral binocular visual field in patients with glaucoma: a pilot study

    PubMed Central

    Ana, Banc; Cristina, Stan; Dorin, Chiselita

    2016-01-01

    Objective: The objective of this study was to evaluate the peripheral binocular visual field (PBVF) in patients with glaucoma using the threshold strategy of Humphrey Field Analyzer. Methods: We conducted a case-control pilot study in which we enrolled 59 patients with glaucoma and 20 controls. All participants were evaluated using a custom PBVF test and central 24° monocular visual field tests for each eye using the threshold strategy. The central binocular visual field (CBVF) was predicted from the monocular tests using the most sensitive point at each field location. The glaucoma patients were grouped according to Hodapp classification and age. The PBVF was compared to controls and the relationship between the PBVF and CBVF was tested. Results: The areas of frame-induced artefacts were determined (over 50° in each temporal field, 24° superiorly and 45° inferiorly) and excluded from interpretation. The patients presented a statistically significant generalized decrease of the peripheral retinal sensitivity compared to controls for Hodapp initial stage - groups aged 50-59 (t = 11.93 > 2.06; p < 0.05) and 60-69 (t = 7.55 > 2.06; p < 0.05). For the initial Hodapp stage there was no significant relationship between PBVF and CBVF (r = 0.39). For the moderate and advanced Hodapp stages, the interpretation of data was done separately for each patient. Conclusions: This pilot study suggests that glaucoma patients present a decrease of PBVF compared to controls and CBVF cannot predict the PBVF in glaucoma. Abbreviations: CBVF = central binocular visual field, PBVF = peripheral binocular visual field, MD = mean deviation PMID:27220228

  6. A Portable Platform for Evaluation of Visual Performance in Glaucoma Patients

    PubMed Central

    Rosen, Peter N.; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Marvasti, Amir H.; Medeiros, Felipe A.

    2015-01-01

    Purpose To propose a new tablet-enabled test for evaluation of visual performance in glaucoma, the PERformance CEntered Portable Test (PERCEPT), and to evaluate its ability to predict history of falls and motor vehicle crashes. Design Cross-sectional study. Methods The study involved 71 patients with glaucomatous visual field defects on standard automated perimetry (SAP) and 59 control subjects. The PERCEPT was based on the concept of increasing visual task difficulty to improve detection of central visual field losses in glaucoma patients. Subjects had to perform a foveal 8-alternative-forced-choice orientation discrimination task, while detecting a simultaneously presented peripheral stimulus within a limited presentation time. Subjects also underwent testing with the Useful Field of View (UFOV) divided attention test. The ability to predict history of motor vehicle crashes and falls was investigated by odds ratios and incident-rate ratios, respectively. Results When adjusted for age, only the PERCEPT processing speed parameter showed significantly larger values in glaucoma compared to controls (difference: 243ms; P<0.001). PERCEPT results had a stronger association with history of motor vehicle crashes and falls than UFOV. Each 1 standard deviation increase in PERCEPT processing speed was associated with an odds ratio of 2.69 (P = 0.003) for predicting history of motor vehicle crashes and with an incident-rate ratio of 1.95 (P = 0.003) for predicting history of falls. Conclusion A portable platform for testing visual function was able to detect functional deficits in glaucoma, and its results were significantly associated with history of involvement in motor vehicle crashes and history of falls. PMID:26445501

  7. Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury

    NASA Astrophysics Data System (ADS)

    Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.

    2008-02-01

    Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.

  8. A multilevel layout algorithm for visualizing physical and genetic interaction networks, with emphasis on their modular organization.

    PubMed

    Tuikkala, Johannes; Vähämaa, Heidi; Salmela, Pekka; Nevalainen, Olli S; Aittokallio, Tero

    2012-03-26

    Graph drawing is an integral part of many systems biology studies, enabling visual exploration and mining of large-scale biological networks. While a number of layout algorithms are available in popular network analysis platforms, such as Cytoscape, it remains poorly understood how well their solutions reflect the underlying biological processes that give rise to the network connectivity structure. Moreover, visualizations obtained using conventional layout algorithms, such as those based on the force-directed drawing approach, may become uninformative when applied to larger networks with dense or clustered connectivity structure. We implemented a modified layout plug-in, named Multilevel Layout, which applies the conventional layout algorithms within a multilevel optimization framework to better capture the hierarchical modularity of many biological networks. Using a wide variety of real life biological networks, we carried out a systematic evaluation of the method in comparison with other layout algorithms in Cytoscape. The multilevel approach provided both biologically relevant and visually pleasant layout solutions in most network types, hence complementing the layout options available in Cytoscape. In particular, it could improve drawing of large-scale networks of yeast genetic interactions and human physical interactions. In more general terms, the biological evaluation framework developed here enables one to assess the layout solutions from any existing or future graph drawing algorithm as well as to optimize their performance for a given network type or structure. By making use of the multilevel modular organization when visualizing biological networks, together with the biological evaluation of the layout solutions, one can generate convenient visualizations for many network biology applications.

  9. Advanced Visualization and Interactive Display Rapid Innovation and Discovery Evaluation Research (VISRIDER) Program Task 6: Point Cloud Visualization Techniques for Desktop and Web Platforms

    DTIC Science & Technology

    2017-04-01

    ADVANCED VISUALIZATION AND INTERACTIVE DISPLAY RAPID INNOVATION AND DISCOVERY EVALUATION RESEARCH (VISRIDER) PROGRAM TASK 6: POINT CLOUD...To) OCT 2013 – SEP 2014 4. TITLE AND SUBTITLE ADVANCED VISUALIZATION AND INTERACTIVE DISPLAY RAPID INNOVATION AND DISCOVERY EVALUATION RESEARCH...various point cloud visualization techniques for viewing large scale LiDAR datasets. Evaluate their potential use for thick client desktop platforms

  10. Directional virtual backbone based data aggregation scheme for Wireless Visual Sensor Networks.

    PubMed

    Zhang, Jing; Liu, Shi-Jian; Tsai, Pei-Wei; Zou, Fu-Min; Ji, Xiao-Rong

    2018-01-01

    Data gathering is a fundamental task in Wireless Visual Sensor Networks (WVSNs). Features of directional antennas and the visual data make WVSNs more complex than the conventional Wireless Sensor Network (WSN). The virtual backbone is a technique, which is capable of constructing clusters. The version associating with the aggregation operation is also referred to as the virtual backbone tree. In most of the existing literature, the main focus is on the efficiency brought by the construction of clusters that the existing methods neglect local-balance problems in general. To fill up this gap, Directional Virtual Backbone based Data Aggregation Scheme (DVBDAS) for the WVSNs is proposed in this paper. In addition, a measurement called the energy consumption density is proposed for evaluating the adequacy of results in the cluster-based construction problems. Moreover, the directional virtual backbone construction scheme is proposed by considering the local-balanced factor. Furthermore, the associated network coding mechanism is utilized to construct DVBDAS. Finally, both the theoretical analysis of the proposed DVBDAS and the simulations are given for evaluating the performance. The experimental results prove that the proposed DVBDAS achieves higher performance in terms of both the energy preservation and the network lifetime extension than the existing methods.

  11. visCOS: An R-package to evaluate model performance of hydrological models

    NASA Astrophysics Data System (ADS)

    Klotz, Daniel; Herrnegger, Mathew; Wesemann, Johannes; Schulz, Karsten

    2016-04-01

    The evaluation of model performance is a central part of (hydrological) modelling. Much attention has been given to the development of evaluation criteria and diagnostic frameworks. (Klemeš, 1986; Gupta et al., 2008; among many others). Nevertheless, many applications exist for which objective functions do not yet provide satisfying summaries. Thus, the necessity to visualize results arises in order to explore a wider range of model capacities, be it strengths or deficiencies. Visualizations are usually devised for specific projects and these efforts are often not distributed to a broader community (e.g. via open source software packages). Hence, the opportunity to explicitly discuss a state-of-the-art presentation technique is often missed. We therefore present a comprehensive R-package for evaluating model performance by visualizing and exploring different aspects of hydrological time-series. The presented package comprises a set of useful plots and visualization methods, which complement existing packages, such as hydroGOF (Zambrano-Bigiarini et al., 2012). It is derived from practical applications of the hydrological models COSERO and COSEROreg (Kling et al., 2014). visCOS, providing an interface in R, represents an easy-to-use software package for visualizing and assessing model performance and can be implemented in the process of model calibration or model development. The package provides functions to load hydrological data into R, clean the data, process, visualize, explore and finally save the results in a consistent way. Together with an interactive zoom function of the time series, an online calculation of the objective functions for variable time-windows is included. Common hydrological objective functions, such as the Nash-Sutcliffe Efficiency and the Kling-Gupta Efficiency, can also be evaluated and visualized in different ways for defined sub-periods like hydrological years or seasonal sections. Many hydrologists use long-term water-balances as a pivotal tool in model evaluation. They allow inferences about different systematic model-shortcomings and are an efficient way for communicating these in practice (Schulz et al., 2015). The evaluation and construction of such water balances is implemented with the presented package. During the (manual) calibration of a model or in the scope of model development, many model runs and iterations are necessary. Thus, users are often interested in comparing different model results in a visual way in order to learn about the model and to analyse parameter-changes on the output. A method to illuminate these differences and the evolution of changes is also included. References: • Gupta, H.V.; Wagener, T.; Liu, Y. (2008): Reconciling theory with observations: elements of a diagnostic approach to model evaluation, Hydrol. Process. 22, doi: 10.1002/hyp.6989. • Klemeš, V. (1986): Operational testing of hydrological simulation models, Hydrolog. Sci. J., doi: 10.1080/02626668609491024. • Kling, H.; Stanzel, P.; Fuchs, M.; and Nachtnebel, H. P. (2014): Performance of the COSERO precipitation-runoff model under non-stationary conditions in basins with different climates, Hydrolog. Sci. J., doi: 10.1080/02626667.2014.959956. • Schulz, K., Herrnegger, M., Wesemann, J., Klotz, D. Senoner, T. (2015): Kalibrierung COSERO - Mur für Pro Vis, Verbund Trading GmbH (Abteilung STG), final report, Institute of Water Management, Hydrology and Hydraulic Engineering, University of Natural Resources and Applied Life Sciences, Vienna, Austria, 217pp. • Zambrano-Bigiarini, M; Bellin, A. (2010): Comparing Goodness-of-fit Measures for Calibration of Models Focused on Extreme Events. European Geosciences Union (EGU), Geophysical Research Abstracts 14, EGU2012-11549-1.

  12. Local coding based matching kernel method for image classification.

    PubMed

    Song, Yan; McLoughlin, Ian Vince; Dai, Li-Rong

    2014-01-01

    This paper mainly focuses on how to effectively and efficiently measure visual similarity for local feature based representation. Among existing methods, metrics based on Bag of Visual Word (BoV) techniques are efficient and conceptually simple, at the expense of effectiveness. By contrast, kernel based metrics are more effective, but at the cost of greater computational complexity and increased storage requirements. We show that a unified visual matching framework can be developed to encompass both BoV and kernel based metrics, in which local kernel plays an important role between feature pairs or between features and their reconstruction. Generally, local kernels are defined using Euclidean distance or its derivatives, based either explicitly or implicitly on an assumption of Gaussian noise. However, local features such as SIFT and HoG often follow a heavy-tailed distribution which tends to undermine the motivation behind Euclidean metrics. Motivated by recent advances in feature coding techniques, a novel efficient local coding based matching kernel (LCMK) method is proposed. This exploits the manifold structures in Hilbert space derived from local kernels. The proposed method combines advantages of both BoV and kernel based metrics, and achieves a linear computational complexity. This enables efficient and scalable visual matching to be performed on large scale image sets. To evaluate the effectiveness of the proposed LCMK method, we conduct extensive experiments with widely used benchmark datasets, including 15-Scenes, Caltech101/256, PASCAL VOC 2007 and 2011 datasets. Experimental results confirm the effectiveness of the relatively efficient LCMK method.

  13. Interactive visual exploration and refinement of cluster assignments.

    PubMed

    Kern, Michael; Lex, Alexander; Gehlenborg, Nils; Johnson, Chris R

    2017-09-12

    With ever-increasing amounts of data produced in biology research, scientists are in need of efficient data analysis methods. Cluster analysis, combined with visualization of the results, is one such method that can be used to make sense of large data volumes. At the same time, cluster analysis is known to be imperfect and depends on the choice of algorithms, parameters, and distance measures. Most clustering algorithms don't properly account for ambiguity in the source data, as records are often assigned to discrete clusters, even if an assignment is unclear. While there are metrics and visualization techniques that allow analysts to compare clusterings or to judge cluster quality, there is no comprehensive method that allows analysts to evaluate, compare, and refine cluster assignments based on the source data, derived scores, and contextual data. In this paper, we introduce a method that explicitly visualizes the quality of cluster assignments, allows comparisons of clustering results and enables analysts to manually curate and refine cluster assignments. Our methods are applicable to matrix data clustered with partitional, hierarchical, and fuzzy clustering algorithms. Furthermore, we enable analysts to explore clustering results in context of other data, for example, to observe whether a clustering of genomic data results in a meaningful differentiation in phenotypes. Our methods are integrated into Caleydo StratomeX, a popular, web-based, disease subtype analysis tool. We show in a usage scenario that our approach can reveal ambiguities in cluster assignments and produce improved clusterings that better differentiate genotypes and phenotypes.

  14. Quality metrics for sensor images

    NASA Technical Reports Server (NTRS)

    Ahumada, AL

    1993-01-01

    Methods are needed for evaluating the quality of augmented visual displays (AVID). Computational quality metrics will help summarize, interpolate, and extrapolate the results of human performance tests with displays. The FLM Vision group at NASA Ames has been developing computational models of visual processing and using them to develop computational metrics for similar problems. For example, display modeling systems use metrics for comparing proposed displays, halftoning optimizing methods use metrics to evaluate the difference between the halftone and the original, and image compression methods minimize the predicted visibility of compression artifacts. The visual discrimination models take as input two arbitrary images A and B and compute an estimate of the probability that a human observer will report that A is different from B. If A is an image that one desires to display and B is the actual displayed image, such an estimate can be regarded as an image quality metric reflecting how well B approximates A. There are additional complexities associated with the problem of evaluating the quality of radar and IR enhanced displays for AVID tasks. One important problem is the question of whether intruding obstacles are detectable in such displays. Although the discrimination model can handle detection situations by making B the original image A plus the intrusion, this detection model makes the inappropriate assumption that the observer knows where the intrusion will be. Effects of signal uncertainty need to be added to our models. A pilot needs to make decisions rapidly. The models need to predict not just the probability of a correct decision, but the probability of a correct decision by the time the decision needs to be made. That is, the models need to predict latency as well as accuracy. Luce and Green have generated models for auditory detection latencies. Similar models are needed for visual detection. Most image quality models are designed for static imagery. Watson has been developing a general spatial-temporal vision model to optimize video compression techniques. These models need to be adapted and calibrated for AVID applications.

  15. A pre- and post-treatment evaluation of vision-related quality of life in uveitis

    PubMed Central

    Rathinam, SR

    2008-01-01

    Aim: To study the effect of treatment on vision-related quality of life (VR-QOL) in uveitis patients. Materials and Methods: Interviewer-administered questionnaire-based evaluation of visual function and VR-QOL in Tamil-speaking adult patients with active uveitis at presentation and follow-up by the same interviewer. Results: Ninety-eight patients participated in this study. There was a statistically significant improvement in VR-QOL in all the scales following treatment (P < 0.001). Patients with chronic uveitis showed better improvement upon treatment than patients with acute uveitis. The visual symptoms scale showed moderate gains following treatment (effect size 0.56). Persons with bilateral disease had poorer mean scores compared to those with unilateral disease. Visual acuity was closely correlated with VR-QOL scores. Conclusion: The VR-QOL measurement has shown that it is sensitive to demonstrate the problems of patients with uveitis irrespective of their demographic profile. The scores improved significantly in patients with uveitis following treatment and have shown close correlation to visual acuity thus demonstrating that VR-QOL is effective in assessing the response to treatment. PMID:18579990

  16. Biological imaging in radiation therapy: role of positron emission tomography.

    PubMed

    Nestle, Ursula; Weber, Wolfgang; Hentschel, Michael; Grosu, Anca-Ligia

    2009-01-07

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.

  17. TOPICAL REVIEW: Biological imaging in radiation therapy: role of positron emission tomography

    NASA Astrophysics Data System (ADS)

    Nestle, Ursula; Weber, Wolfgang; Hentschel, Michael; Grosu, Anca-Ligia

    2009-01-01

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.

  18. [Comparison of two different methods of analgesia. Postoperative course after colorectal cancer surgery].

    PubMed

    Rimaitis, Kestutis; Marchertiene, Irena; Pavalkis, Dainius

    2003-01-01

    The purpose of our study is to compare two methods of postoperative analgesia in colorectal cancer patients after resectional operations, and to evaluate advantages and limitations of each method on the postoperative course of these patients. One hundred patients scheduled to undergo elective colorectal cancer surgery were randomized into two groups; after general anesthesia, one group received epidural analgesia (n=50) and the second one - intramuscular pethidine analgesia (n=50). Visual analogue scale at rest and on coughing was used to compare intensiveness of pain between the two groups during the day of surgery and first three postoperative days. Patients' mood and self-satisfaction were evaluated using self-assessment manikin scale. Side effects of both analgesia techniques were registered. All complications and postoperative hospital stay were also evaluated. Visual analogue scale pain scores at rest and on coughing were significantly better in epidural analgesia group as compared to systemic intramuscular pethidine analgesia group (p<0.05). Additional analgesics were needed for 10 (20%) and 28 (56%) patients respectively to keep visual analogue scale pain scores below 5. Adverse effects such as profound sedation, nausea and vomiting were more frequent in systemic intramuscular pethidine group, but pruritus - very uncommon to compare with epidural analgesia group (p<0.05). There were no significant differences between the two groups in respect to complications and postoperative hospital stay. Epidural analgesia has demonstrated significantly better effectiveness than intramuscular pethidine analgesia after colorectal cancer surgery with fewer adverse events. Self-assessment manikin scores showed better self-satisfaction in patients of epidural analgesia group as compared to patients in systemic pethidine group.

  19. Barack Obama Blindness (BOB): Absence of Visual Awareness to a Single Object.

    PubMed

    Persuh, Marjan; Melara, Robert D

    2016-01-01

    In two experiments, we evaluated whether a perceiver's prior expectations could alone obliterate his or her awareness of a salient visual stimulus. To establish expectancy, observers first made a demanding visual discrimination on each of three baseline trials. Then, on a fourth, critical trial, a single, salient and highly visible object appeared in full view at the center of the visual field and in the absence of any competing visual input. Surprisingly, fully half of the participants were unaware of the solitary object in front of their eyes. Dramatically, observers were blind even when the only stimulus on display was the face of U.S. President Barack Obama. We term this novel, counterintuitive phenomenon, Barack Obama Blindness (BOB). Employing a method that rules out putative memory effects by probing awareness immediately after presentation of the critical stimulus, we demonstrate that the BOB effect is a true failure of conscious vision.

  20. Barack Obama Blindness (BOB): Absence of Visual Awareness to a Single Object

    PubMed Central

    Persuh, Marjan; Melara, Robert D.

    2016-01-01

    In two experiments, we evaluated whether a perceiver’s prior expectations could alone obliterate his or her awareness of a salient visual stimulus. To establish expectancy, observers first made a demanding visual discrimination on each of three baseline trials. Then, on a fourth, critical trial, a single, salient and highly visible object appeared in full view at the center of the visual field and in the absence of any competing visual input. Surprisingly, fully half of the participants were unaware of the solitary object in front of their eyes. Dramatically, observers were blind even when the only stimulus on display was the face of U.S. President Barack Obama. We term this novel, counterintuitive phenomenon, Barack Obama Blindness (BOB). Employing a method that rules out putative memory effects by probing awareness immediately after presentation of the critical stimulus, we demonstrate that the BOB effect is a true failure of conscious vision. PMID:27047362

  1. The visual communication in the optonometric scales.

    PubMed

    Dantas, Rosane Arruda; Pagliuca, Lorita Marlena Freitag

    2006-01-01

    Communication through vision involves visual apprenticeship that demands ocular integrity, which results in the importance of the evaluation of visual acuity. The scale of images, formed by optotypes, is a method for the verification of visual acuity in kindergarten children. To identify the optotype the child needs to know the image in analysis. Given the importance of visual communication during the process of construction of the scale of images, one presents a bibliographic, analytical study aiming at thinking about the principles for the construction of those tables. One considers the draw inserted as an optotype as a non-verbal symbolic expression of the body and/or of the environment constructed based on the caption of experiences by the individual. One contests the indiscriminate use of images, for one understands that there must be previous knowledge. Despite the subjectivity of the optotypes, the scales continue valid if one adapts images to those of the universe of the children to be examined.

  2. The time-adjusted gradual replacement injection method enables better visualization of the right heart.

    PubMed

    Nakahara, Takehiro; Jinzaki, Masahiro; Niwamae, Nogiku; Saito, Yuuichirou; Arai, Masashi; Tsushima, Yoshito; Kuribayashi, Sachio; Kurabayashi, Masahiko

    2014-01-01

    Despite the improvement of cardiac CT, right heart visualization remains challenging. We herein describe a new method, called the time-adjusted gradual replacement injection protocol. The aim of this study was to compare this protocol with the split-bolus injection protocol. Fifty-two patients who had undergone dual-source cardiac CT were retrospectively recruited. Twenty-six patients were injected by using the split-bolus injection protocol, and 26 patients were injected by using the time-adjusted gradual replacement injection protocol. For this method, we injected contrast medium for 10 seconds at a flow rate of 0.07 × body weight mL/s, then gradually replaced the contrast material with saline until 2 seconds before finishing the scans. The CT attenuation was measured in 4 chambers, the aorta, and the coronary arteries. The visualization of the anatomic structures and the occurrence and severity of streak artifacts were scored for the cardiac structures in the heart. For the analyses, either Welch t-test or Student t-test was performed. In the right heart, the CT values and visualization scores were significantly higher in the time-adjusted replacement injection group than in the split-bolus injection group, whereas the artifact scores were comparable between the 2 groups. The CT values, visualization scores, and artifact scores of the left heart were not significantly different between the 2 groups. In this study, the time-adjusted gradual replacement injection protocol provided excellent attenuation for visualization of the right heart. This method may help to accurately evaluate the right cardiac anatomy and thereby identify any potential diseases. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. Short communication: Semiquantitative assessment of 99mTc-EDDA/HYNIC-TOC scintigraphy in differentiation of solitary pulmonary nodules--a complementary role to visual analysis.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-02-01

    The aim of this study was the assessment of a value of a semiquantitative analysis of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC as a radiopharmaceutical (RPH) in differential diagnosis of solitary pulmonary nodules (SPNs), as a method complementary to visual evaluation of scintigrams. Scintigraphic images of 59 patients (33 males and 26 females between 34 and 78 years of age, mean value, 57) with SPN on chest radiographs (39 malignant and 20 benign) were retrospectively assessed semiquantitatively. Visual scintigram analysis was made earlier, prospectively. Nodule diameters ranged from 1 to 4 (mean 2.2) cm. A single photon emission computed tomography (SPECT) acquisition was performed at 2-4 hours after administration of 740 to 925 MBq of a RPH. Verification of scintigraphic results was based on a pathological examination of tumor samples (histopathology or cytology) and, in some cases, on bacteriological studies. As an additional criterion for tumor benignity, its stable size in a time interval not shorter than 3 years was accepted. A simple, semiquantitative method for assessment of radiopharmaceutical uptake in SPNs was used, based on "count sample" taken from tumor center (T) in relation to radiopharmaceutical concentration in the background (B) measured in the contralateral lung. A criterion for optimal differentiation between malignant and benign nodules (T/B ratio threshold value) was introduced, based on a receiver operating characteristic (ROC) curve. Additionally, a value of T/B ratio was searched for, excluding tumor benignity with high probability. Visual analysis of scintigrams revealed enhanced uptake of RPH at 36 of 39 (92%) sites, corresponding to locations of malignant nodules (including 34 of 35-97% cases of lung cancer). In 13 of 20 (65%) benign nodules, true negative results were obtained. Accuracy of the method equalled 83%. Optimal differentiation between malignant and benign nodules was found for a value of a T/B ratio amounting to 2. The semiquantitative method gave true positive results in 35 of 39 (90%) malignant nodules (as in visual method in 34 of 35-97% cases of lung cancer). True negative results were obtained in 17 of 20 (85%) benign cases. Accuracy of the method reached 88%. A T/B ratio exceeding 4 excluded tumor benignity with high probability. A simple method, of quantitatively assessing 99mTc-EDDA/HYNICTOC uptake in solitary pulmonary nodules by means of a T/B ratio can play a role that is complementary to the visual evaluation of scintigrams. It improves low specificity of the method in the detection of malignant nodules, without significant reduction of its sensitivity and provides a T/B ratio excluding tumor benignity with high probability.

  4. Geovisual analytics to enhance spatial scan statistic interpretation: an analysis of U.S. cervical cancer mortality.

    PubMed

    Chen, Jin; Roth, Robert E; Naito, Adam T; Lengerich, Eugene J; Maceachren, Alan M

    2008-11-07

    Kulldorff's spatial scan statistic and its software implementation - SaTScan - are widely used for detecting and evaluating geographic clusters. However, two issues make using the method and interpreting its results non-trivial: (1) the method lacks cartographic support for understanding the clusters in geographic context and (2) results from the method are sensitive to parameter choices related to cluster scaling (abbreviated as scaling parameters), but the system provides no direct support for making these choices. We employ both established and novel geovisual analytics methods to address these issues and to enhance the interpretation of SaTScan results. We demonstrate our geovisual analytics approach in a case study analysis of cervical cancer mortality in the U.S. We address the first issue by providing an interactive visual interface to support the interpretation of SaTScan results. Our research to address the second issue prompted a broader discussion about the sensitivity of SaTScan results to parameter choices. Sensitivity has two components: (1) the method can identify clusters that, while being statistically significant, have heterogeneous contents comprised of both high-risk and low-risk locations and (2) the method can identify clusters that are unstable in location and size as the spatial scan scaling parameter is varied. To investigate cluster result stability, we conducted multiple SaTScan runs with systematically selected parameters. The results, when scanning a large spatial dataset (e.g., U.S. data aggregated by county), demonstrate that no single spatial scan scaling value is known to be optimal to identify clusters that exist at different scales; instead, multiple scans that vary the parameters are necessary. We introduce a novel method of measuring and visualizing reliability that facilitates identification of homogeneous clusters that are stable across analysis scales. Finally, we propose a logical approach to proceed through the analysis of SaTScan results. The geovisual analytics approach described in this manuscript facilitates the interpretation of spatial cluster detection methods by providing cartographic representation of SaTScan results and by providing visualization methods and tools that support selection of SaTScan parameters. Our methods distinguish between heterogeneous and homogeneous clusters and assess the stability of clusters across analytic scales. We analyzed the cervical cancer mortality data for the United States aggregated by county between 2000 and 2004. We ran SaTScan on the dataset fifty times with different parameter choices. Our geovisual analytics approach couples SaTScan with our visual analytic platform, allowing users to interactively explore and compare SaTScan results produced by different parameter choices. The Standardized Mortality Ratio and reliability scores are visualized for all the counties to identify stable, homogeneous clusters. We evaluated our analysis result by comparing it to that produced by other independent techniques including the Empirical Bayes Smoothing and Kafadar spatial smoother methods. The geovisual analytics approach introduced here is developed and implemented in our Java-based Visual Inquiry Toolkit.

  5. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  6. Multi Agent Reward Analysis for Learning in Noisy Domains

    NASA Technical Reports Server (NTRS)

    Tumer, Kagan; Agogino, Adrian K.

    2005-01-01

    In many multi agent learning problems, it is difficult to determine, a priori, the agent reward structure that will lead to good performance. This problem is particularly pronounced in continuous, noisy domains ill-suited to simple table backup schemes commonly used in TD(lambda)/Q-learning. In this paper, we present a new reward evaluation method that allows the tradeoff between coordination among the agents and the difficulty of the learning problem each agent faces to be visualized. This method is independent of the learning algorithm and is only a function of the problem domain and the agents reward structure. We then use this reward efficiency visualization method to determine an effective reward without performing extensive simulations. We test this method in both a static and a dynamic multi-rover learning domain where the agents have continuous state spaces and where their actions are noisy (e.g., the agents movement decisions are not always carried out properly). Our results show that in the more difficult dynamic domain, the reward efficiency visualization method provides a two order of magnitude speedup in selecting a good reward. Most importantly it allows one to quickly create and verify rewards tailored to the observational limitations of the domain.

  7. Use of Sine Shaped High-Frequency Rhythmic Visual Stimuli Patterns for SSVEP Response Analysis and Fatigue Rate Evaluation in Normal Subjects

    PubMed Central

    Keihani, Ahmadreza; Shirzhiyan, Zahra; Farahi, Morteza; Shamsi, Elham; Mahnam, Amin; Makkiabadi, Bahador; Haidari, Mohsen R.; Jafari, Amir H.

    2018-01-01

    Background: Recent EEG-SSVEP signal based BCI studies have used high frequency square pulse visual stimuli to reduce subjective fatigue. However, the effect of total harmonic distortion (THD) has not been considered. Compared to CRT and LCD monitors, LED screen displays high-frequency wave with better refresh rate. In this study, we present high frequency sine wave simple and rhythmic patterns with low THD rate by LED to analyze SSVEP responses and evaluate subjective fatigue in normal subjects. Materials and Methods: We used patterns of 3-sequence high-frequency sine waves (25, 30, and 35 Hz) to design our visual stimuli. Nine stimuli patterns, 3 simple (repetition of each of above 3 frequencies e.g., P25-25-25) and 6 rhythmic (all of the frequencies in 6 different sequences e.g., P25-30-35) were chosen. A hardware setup with low THD rate (<0.1%) was designed to present these patterns on LED. Twenty two normal subjects (aged 23–30 (25 ± 2.1) yrs) were enrolled. Visual analog scale (VAS) was used for subjective fatigue evaluation after presentation of each stimulus pattern. PSD, CCA, and LASSO methods were employed to analyze SSVEP responses. The data including SSVEP features and fatigue rate for different visual stimuli patterns were statistically evaluated. Results: All 9 visual stimuli patterns elicited SSVEP responses. Overall, obtained accuracy rates were 88.35% for PSD and > 90% for CCA and LASSO (for TWs > 1 s). High frequency rhythmic patterns group with low THD rate showed higher accuracy rate (99.24%) than simple patterns group (98.48%). Repeated measure ANOVA showed significant difference between rhythmic pattern features (P < 0.0005). Overall, there was no significant difference between the VAS of rhythmic [3.85 ± 2.13] compared to the simple patterns group [3.96 ± 2.21], (P = 0.63). Rhythmic group had lower within group VAS variation (min = P25-30-35 [2.90 ± 2.45], max = P35-25-30 [4.81 ± 2.65]) as well as least individual pattern VAS (P25-30-35). Discussion and Conclusion: Overall, rhythmic and simple pattern groups had higher and similar accuracy rates. Rhythmic stimuli patterns showed insignificantly lower fatigue rate than simple patterns. We conclude that both rhythmic and simple visual high frequency sine wave stimuli require further research for human subject SSVEP-BCI studies. PMID:29892219

  8. Use of Sine Shaped High-Frequency Rhythmic Visual Stimuli Patterns for SSVEP Response Analysis and Fatigue Rate Evaluation in Normal Subjects.

    PubMed

    Keihani, Ahmadreza; Shirzhiyan, Zahra; Farahi, Morteza; Shamsi, Elham; Mahnam, Amin; Makkiabadi, Bahador; Haidari, Mohsen R; Jafari, Amir H

    2018-01-01

    Background: Recent EEG-SSVEP signal based BCI studies have used high frequency square pulse visual stimuli to reduce subjective fatigue. However, the effect of total harmonic distortion (THD) has not been considered. Compared to CRT and LCD monitors, LED screen displays high-frequency wave with better refresh rate. In this study, we present high frequency sine wave simple and rhythmic patterns with low THD rate by LED to analyze SSVEP responses and evaluate subjective fatigue in normal subjects. Materials and Methods: We used patterns of 3-sequence high-frequency sine waves (25, 30, and 35 Hz) to design our visual stimuli. Nine stimuli patterns, 3 simple (repetition of each of above 3 frequencies e.g., P25-25-25) and 6 rhythmic (all of the frequencies in 6 different sequences e.g., P25-30-35) were chosen. A hardware setup with low THD rate (<0.1%) was designed to present these patterns on LED. Twenty two normal subjects (aged 23-30 (25 ± 2.1) yrs) were enrolled. Visual analog scale (VAS) was used for subjective fatigue evaluation after presentation of each stimulus pattern. PSD, CCA, and LASSO methods were employed to analyze SSVEP responses. The data including SSVEP features and fatigue rate for different visual stimuli patterns were statistically evaluated. Results: All 9 visual stimuli patterns elicited SSVEP responses. Overall, obtained accuracy rates were 88.35% for PSD and > 90% for CCA and LASSO (for TWs > 1 s). High frequency rhythmic patterns group with low THD rate showed higher accuracy rate (99.24%) than simple patterns group (98.48%). Repeated measure ANOVA showed significant difference between rhythmic pattern features ( P < 0.0005). Overall, there was no significant difference between the VAS of rhythmic [3.85 ± 2.13] compared to the simple patterns group [3.96 ± 2.21], ( P = 0.63). Rhythmic group had lower within group VAS variation (min = P25-30-35 [2.90 ± 2.45], max = P35-25-30 [4.81 ± 2.65]) as well as least individual pattern VAS (P25-30-35). Discussion and Conclusion: Overall, rhythmic and simple pattern groups had higher and similar accuracy rates. Rhythmic stimuli patterns showed insignificantly lower fatigue rate than simple patterns. We conclude that both rhythmic and simple visual high frequency sine wave stimuli require further research for human subject SSVEP-BCI studies.

  9. Multidimensional structured data visualization method and apparatus, text visualization method and apparatus, method and apparatus for visualizing and graphically navigating the world wide web, method and apparatus for visualizing hierarchies

    DOEpatents

    Risch, John S [Kennewick, WA; Dowson, Scott T [West Richland, WA; Hart, Michelle L [Richland, WA; Hatley, Wes L [Kennewick, WA

    2008-05-13

    A method of displaying correlations among information objects comprises receiving a query against a database; obtaining a query result set; and generating a visualization representing the components of the result set, the visualization including one of a plane and line to represent a data field, nodes representing data values, and links showing correlations among fields and values. Other visualization methods and apparatus are disclosed.

  10. Multidimensional structured data visualization method and apparatus, text visualization method and apparatus, method and apparatus for visualizing and graphically navigating the world wide web, method and apparatus for visualizing hierarchies

    DOEpatents

    Risch, John S [Kennewick, WA; Dowson, Scott T [West Richland, WA

    2012-03-06

    A method of displaying correlations among information objects includes receiving a query against a database; obtaining a query result set; and generating a visualization representing the components of the result set, the visualization including one of a plane and line to represent a data field, nodes representing data values, and links showing correlations among fields and values. Other visualization methods and apparatus are disclosed.

  11. Critique of Sikkink and Keane's comparison of surface fuel sampling techniques

    Treesearch

    Clinton S. Wright; Roger D. Ottmar; Robert E. Vihnanek

    2010-01-01

    The 2008 paper of Sikkink and Keane compared several methods to estimate surface fuel loading in western Montana: two widely used inventory techniques (planar intersect and fixed-area plot) and three methods that employ photographs as visual guides (photo load, photoload macroplot and photo series). We feel, however, that their study design was inadequate to evaluate...

  12. The Keyword Method of Vocabulary Acquisition: An Experimental Evaluation.

    ERIC Educational Resources Information Center

    Griffith, Douglas

    The keyword method of vocabulary acquisition is a two-step mnemonic technique for learning vocabulary terms. The first step, the acoustic link, generates a keyword based on the sound of the foreign word. The second step, the imagery link, ties the keyword to the meaning of the item to be learned, via an interactive visual image or other…

  13. Spatial Visualization Learning in Engineering: Traditional Methods vs. a Web-Based Tool

    ERIC Educational Resources Information Center

    Pedrosa, Carlos Melgosa; Barbero, Basilio Ramos; Miguel, Arturo Román

    2014-01-01

    This study compares an interactive learning manager for graphic engineering to develop spatial vision (ILMAGE_SV) to traditional methods. ILMAGE_SV is an asynchronous web-based learning tool that allows the manipulation of objects with a 3D viewer, self-evaluation, and continuous assessment. In addition, student learning may be monitored, which…

  14. Non-cultural methods of human microflora evaluation for the benefit of crew medical control in confined habitat

    NASA Astrophysics Data System (ADS)

    Viacheslav, Ilyin; Lana, Moukhamedieva; Georgy, Osipov; Aleksey, Batov; Zoya, Soloviova; Robert, Mardanov; Yana, Panina; Anna, Gegenava

    2011-05-01

    Current control of human microflora is a great problem not only for the space medicine but also for practical health care. Due to many reasons its realization by classical bacteriological method is difficult in practical application or cannot be done. To evaluate non-cultural methods of microbial control of crews in a confined habitat we evaluated two different methods. The first method is based on digital treatment of microbial visual images, appearing after gram staining of microbial material from natural sample. This way the rate between gram-positive and gram-negative microbe could be gained as well as differentiation of rods and cocci could be attained, which is necessary for primary evaluation of human microbial cenosis in remote confined habitats. The other non-culture method of human microflora evaluation is gas chromatomass spectrometry (gcms) analysis of swabs gathered from different body sites. Gc-ms testing of swabs allows one to validate quantitative and special microflora based on specific lipid markers analysis.

  15. Imaging Stem Cells Implanted in Infarcted Myocardium

    PubMed Central

    Zhou, Rong; Acton, Paul D.; Ferrari, Victor A.

    2008-01-01

    Stem cell–based cellular cardiomyoplasty represents a promising therapy for myocardial infarction. Noninvasive imaging techniques would allow the evaluation of survival, migration, and differentiation status of implanted stem cells in the same subject over time. This review describes methods for cell visualization using several corresponding noninvasive imaging modalities, including magnetic resonance imaging, positron emission tomography, single-photon emission computed tomography, and bioluminescent imaging. Reporter-based cell visualization is compared with direct cell labeling for short- and long-term cell tracking. PMID:17112999

  16. Visual information mining in remote sensing image archives

    NASA Astrophysics Data System (ADS)

    Pelizzari, Andrea; Descargues, Vincent; Datcu, Mihai P.

    2002-01-01

    The present article focuses on the development of interactive exploratory tools for visually mining the image content in large remote sensing archives. Two aspects are treated: the iconic visualization of the global information in the archive and the progressive visualization of the image details. The proposed methods are integrated in the Image Information Mining (I2M) system. The images and image structure in the I2M system are indexed based on a probabilistic approach. The resulting links are managed by a relational data base. Both the intrinsic complexity of the observed images and the diversity of user requests result in a great number of associations in the data base. Thus new tools have been designed to visualize, in iconic representation the relationships created during a query or information mining operation: the visualization of the query results positioned on the geographical map, quick-looks gallery, visualization of the measure of goodness of the query, visualization of the image space for statistical evaluation purposes. Additionally the I2M system is enhanced with progressive detail visualization in order to allow better access for operator inspection. I2M is a three-tier Java architecture and is optimized for the Internet.

  17. Finding regions of interest in pathological images: an attentional model approach

    NASA Astrophysics Data System (ADS)

    Gómez, Francisco; Villalón, Julio; Gutierrez, Ricardo; Romero, Eduardo

    2009-02-01

    This paper introduces an automated method for finding diagnostic regions-of-interest (RoIs) in histopathological images. This method is based on the cognitive process of visual selective attention that arises during a pathologist's image examination. Specifically, it emulates the first examination phase, which consists in a coarse search for tissue structures at a "low zoom" to separate the image into relevant regions.1 The pathologist's cognitive performance depends on inherent image visual cues - bottom-up information - and on acquired clinical medicine knowledge - top-down mechanisms -. Our pathologist's visual attention model integrates the latter two components. The selected bottom-up information includes local low level features such as intensity, color, orientation and texture information. Top-down information is related to the anatomical and pathological structures known by the expert. A coarse approximation to these structures is achieved by an oversegmentation algorithm, inspired by psychological grouping theories. The algorithm parameters are learned from an expert pathologist's segmentation. Top-down and bottom-up integration is achieved by calculating a unique index for each of the low level characteristics inside the region. Relevancy is estimated as a simple average of these indexes. Finally, a binary decision rule defines whether or not a region is interesting. The method was evaluated on a set of 49 images using a perceptually-weighted evaluation criterion, finding a quality gain of 3dB when comparing to a classical bottom-up model of attention.

  18. Plasticity of the human visual system after retinal gene therapy in patients with Leber’s congenital amaurosis

    PubMed Central

    Ashtari, Manzar; Zhang, Hui; Cook, Philip A.; Cyckowski, Laura L.; Shindler, Kenneth S.; Marshall, Kathleen A.; Aravand, Puya; Vossough, Arastoo; Gee, James C.; Maguire, Albert M.; Baker, Chris I.; Bennett, Jean

    2015-01-01

    Much of our knowledge of the mechanisms underlying plasticity in the visual cortex in response to visual impairment, vision restoration, and environmental interactions comes from animal studies. We evaluated human brain plasticity in a group of patients with Leber’s congenital amaurosis (LCA), who regained vision through gene therapy. Using non-invasive multimodal neuroimaging methods, we demonstrated that reversing blindness with gene therapy promoted long-term structural plasticity in the visual pathways emanating from the treated retina of LCA patients. The data revealed improvements and normalization along the visual fibers corresponding to the site of retinal injection of the gene therapy vector carrying the therapeutic gene in the treated eye compared to the visual pathway for the untreated eye of LCA patients. After gene therapy, the primary visual pathways (for example, geniculostriate fibers) in the treated retina were similar to those of sighted control subjects, whereas the primary visual pathways of the untreated retina continued to deteriorate. Our results suggest that visual experience, enhanced by gene therapy, may be responsible for the reorganization and maturation of synaptic connectivity in the visual pathways of the treated eye in LCA patients. The interactions between the eye and the brain enabled improved and sustained long-term visual function in patients with LCA after gene therapy. PMID:26180100

  19. Automated quantification of renal interstitial fibrosis for computer-aided diagnosis: A comprehensive tissue structure segmentation method.

    PubMed

    Tey, Wei Keat; Kuang, Ye Chow; Ooi, Melanie Po-Leen; Khoo, Joon Joon

    2018-03-01

    Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses. This study proposes an automated quantification system for measuring the amount of interstitial fibrosis in renal biopsy images as a consistent basis of comparison among pathologists. The system extracts and segments the renal tissue structures based on colour information and structural assumptions of the tissue structures. The regions in the biopsy representing the interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area and quantified as a percentage of the total area of the biopsy sample. A ground truth image dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated a good correlation in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses due to the uncertainties in human judgement. An automated quantification system for accurately measuring the amount of interstitial fibrosis in renal biopsy images is presented as a consistent basis of comparison among pathologists. The system identifies the renal tissue structures through knowledge-based rules employing colour space transformations and structural features extraction from the images. In particular, the renal glomerulus identification is based on a multiscale textural feature analysis and a support vector machine. The regions in the biopsy representing interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area. The experiments conducted evaluate the system in terms of quantification accuracy, intra- and inter-observer variability in visual quantification by pathologists, and the effect introduced by the automated quantification system on the pathologists' diagnosis. A 40-image ground truth dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated an average error of 9 percentage points in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists involving samples from 70 kidney patients also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. The accuracy of the proposed quantification system has been validated with the ground truth dataset and compared against the pathologists' quantification results. It has been shown that the correlation between different pathologists' estimation of interstitial fibrosis area has significantly improved, demonstrating the effectiveness of the quantification system as a diagnostic aide. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Establishing the fundamentals for an elephant early warning and monitoring system.

    PubMed

    Zeppelzauer, Matthias; Stoeger, Angela S

    2015-09-04

    The decline of habitat for elephants due to expanding human activity is a serious conservation problem. This has continuously escalated the human-elephant conflict in Africa and Asia. Elephants make extensive use of powerful infrasonic calls (rumbles) that travel distances of up to several kilometers. This makes elephants well-suited for acoustic monitoring because it enables detecting elephants even if they are out of sight. In sight, their distinct visual appearance makes them a good candidate for visual monitoring. We provide an integrated overview of our interdisciplinary project that established the scientific fundamentals for a future early warning and monitoring system for humans who regularly experience serious conflict with elephants. We first draw the big picture of an early warning and monitoring system, then review the developed solutions for automatic acoustic and visual detection, discuss specific challenges and present open future work necessary to build a robust and reliable early warning and monitoring system that is able to operate in situ. We present a method for the automated detection of elephant rumbles that is robust to the diverse noise sources present in situ. We evaluated the method on an extensive set of audio data recorded under natural field conditions. Results show that the proposed method outperforms existing approaches and accurately detects elephant rumbles. Our visual detection method shows that tracking elephants in wildlife videos (of different sizes and postures) is feasible and particularly robust at near distances. From our project results we draw a number of conclusions that are discussed and summarized. We clearly identified the most critical challenges and necessary improvements of the proposed detection methods and conclude that our findings have the potential to form the basis for a future automated early warning system for elephants. We discuss challenges that need to be solved and summarize open topics in the context of a future early warning and monitoring system. We conclude that a long-term evaluation of the presented methods in situ using real-time prototypes is the most important next step to transfer the developed methods into practical implementation.

  1. Visual words for lip-reading

    NASA Astrophysics Data System (ADS)

    Hassanat, Ahmad B. A.; Jassim, Sabah

    2010-04-01

    In this paper, the automatic lip reading problem is investigated, and an innovative approach to providing solutions to this problem has been proposed. This new VSR approach is dependent on the signature of the word itself, which is obtained from a hybrid feature extraction method dependent on geometric, appearance, and image transform features. The proposed VSR approach is termed "visual words". The visual words approach consists of two main parts, 1) Feature extraction/selection, and 2) Visual speech feature recognition. After localizing face and lips, several visual features for the lips where extracted. Such as the height and width of the mouth, mutual information and the quality measurement between the DWT of the current ROI and the DWT of the previous ROI, the ratio of vertical to horizontal features taken from DWT of ROI, The ratio of vertical edges to horizontal edges of ROI, the appearance of the tongue and the appearance of teeth. Each spoken word is represented by 8 signals, one of each feature. Those signals maintain the dynamic of the spoken word, which contains a good portion of information. The system is then trained on these features using the KNN and DTW. This approach has been evaluated using a large database for different people, and large experiment sets. The evaluation has proved the visual words efficiency, and shown that the VSR is a speaker dependent problem.

  2. Validation of a Low-Cost Paper-Based Screening Test for Sickle Cell Anemia

    PubMed Central

    Piety, Nathaniel Z.; Yang, Xiaoxi; Kanter, Julie; Vignes, Seth M.; George, Alex; Shevkoplyas, Sergey S.

    2016-01-01

    Background The high childhood mortality and life-long complications associated with sickle cell anemia (SCA) in developing countries could be significantly reduced with effective prophylaxis and education if SCA is diagnosed early in life. However, conventional laboratory methods used for diagnosing SCA remain prohibitively expensive and impractical in this setting. This study describes the clinical validation of a low-cost paper-based test for SCA that can accurately identify sickle trait carriers (HbAS) and individuals with SCA (HbSS) among adults and children over 1 year of age. Methods and Findings In a population of healthy volunteers and SCA patients in the United States (n = 55) the test identified individuals whose blood contained any HbS (HbAS and HbSS) with 100% sensitivity and 100% specificity for both visual evaluation and automated analysis, and detected SCA (HbSS) with 93% sensitivity and 94% specificity for visual evaluation and 100% sensitivity and 97% specificity for automated analysis. In a population of post-partum women (with a previously unknown SCA status) at a primary obstetric hospital in Cabinda, Angola (n = 226) the test identified sickle cell trait carriers with 94% sensitivity and 97% specificity using visual evaluation (none of the women had SCA). Notably, our test permits instrument- and electricity-free visual diagnostics, requires minimal training to be performed, can be completed within 30 minutes, and costs about $0.07 in test-specific consumable materials. Conclusions Our results validate the paper-based SCA test as a useful low-cost tool for screening adults and children for sickle trait and disease and demonstrate its practicality in resource-limited clinical settings. PMID:26735691

  3. Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

    PubMed

    Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio

    2015-02-01

    To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.

  4. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  5. Evaluating the use of gas discharge visualization to measure massage therapy outcomes

    PubMed Central

    Haun, Jolie; Patel, Nitin; Schwartz, Gary; Ritenbaugh, Cheryl

    2017-01-01

    Background The purpose of this study was to evaluate the short-term effects of massage therapy using gas discharge visualization (GDV), a computerized biophysical electrophoton capture (EPC), in tandem with traditional self-report measures to evaluate the use of GDV measurement to assess the bioenergetic whole-person effects of massage therapy. Methods This study used a single treatment group, pre–post-repeated measures design with a sample of 23 healthy adults. This study utilized a single 50-min full-body relaxation massage with participants. GDV measurement method, an EPC, and traditional paper-based measures evaluating pain, stress, muscle tension, and well-being were used to assess intervention outcomes. Results Significant differences were found between pre- and post-measures of well-being, pain, stress, muscle tension, and GDV parameters. Pearson correlations indicate the GDV measure is correlated with pain and stress, variables that impact the whole person. Conclusions This study demonstrates that GDV parameters may be used to indicate significant bioenergetic change from pre- to post-massage. Findings warrant further investigation with a larger diverse sample size and control group to further explore GDV as a measure of whole-person bioenergetic effects associated with massage. PMID:26087069

  6. Efficient in-situ visualization of unsteady flows in climate simulation

    NASA Astrophysics Data System (ADS)

    Vetter, Michael; Olbrich, Stephan

    2017-04-01

    The simulation of climate data tends to produce very large data sets, which hardly can be processed in classical post-processing visualization applications. Typically, the visualization pipeline consisting of the processes data generation, visualization mapping and rendering is distributed into two parts over the network or separated via file transfer. Within most traditional post-processing scenarios the simulation is done on a supercomputer whereas the data analysis and visualization is done on a graphics workstation. That way temporary data sets with huge volume have to be transferred over the network, which leads to bandwidth bottlenecks and volume limitations. The solution to this issue is the avoidance of temporary storage, or at least significant reduction of data complexity. Within the Climate Visualization Lab - as part of the Cluster of Excellence "Integrated Climate System Analysis and Prediction" (CliSAP) at the University of Hamburg, in cooperation with the German Climate Computing Center (DKRZ) - we develop and integrate an in-situ approach. Our software framework DSVR is based on the separation of the process chain between the mapping and the rendering processes. It couples the mapping process directly to the simulation by calling methods of a parallelized data extraction library, which create a time-based sequence of geometric 3D scenes. This sequence is stored on a special streaming server with an interactive post-filtering option and then played-out asynchronously in a separate 3D viewer application. Since the rendering is part of this viewer application, the scenes can be navigated interactively. In contrast to other in-situ approaches where 2D images are created as part of the simulation or synchronous co-visualization takes place, our method supports interaction in 3D space and in time, as well as fixed frame rates. To integrate in-situ processing based on our DSVR framework and methods in the ICON climate model, we are continuously evolving the data structures and mapping algorithms of the framework to support the ICON model's native grid structures, since DSVR originally was designed for rectilinear grids only. We now have implemented a new output module to ICON to take advantage of the DSVR visualization. The visualization can be configured as most output modules by using a specific namelist and is exemplarily integrated within the non-hydrostatic atmospheric model time loop. With the integration of a DSVR based in-situ pathline extraction within ICON, a further milestone is reached. The pathline algorithm as well as the grid data structures have been optimized for the domain decomposition used for the parallelization of ICON based on MPI and OpenMP. The software implementation and evaluation is done on the supercomputers at DKRZ. In principle, the data complexity is reduced from O(n3) to O(m), where n is the grid resolution and m the number of supporting point of all pathlines. The stability and scalability evaluation is done using Atmospheric Model Intercomparison Project (AMIP) runs. We will give a short introduction in our software framework, as well as a short overview on the implementation and usage of DSVR within ICON. Furthermore, we will present visualization and evaluation results of sample applications.

  7. Visual efficiency among teenaged athletes and non-athletes

    PubMed Central

    Omar, Rokiah; Kuan, Yau Meng; Zuhairi, Nurul Atikah; Manan, Faudziah Abd; Knight, Victor Feizal

    2017-01-01

    AIM To compare visual efficiency, specifically accom-modation, vergence, and oculomotor functions among athletes and non-athletes. METHODS A cross-sectional study on sports vision screening was used to evaluate the visual skills of 214 elementary students (107 athletes, 107 non-athletes), aged between 13 and 16y. The visual screening assessed visual parameters such as ocular motor alignment, accommodation, and vergence functions. RESULTS Mean visual parameters were compared between age-group matched athletes (mean age 14.82±0.98y) and non-athletes (mean age 15.00±1.04y). The refractive errors of all participants were corrected to maximal attainable best corrected visual acuity of logMAR 0.0. Accommodation function assessment evaluated amplitude of accommodation and accommodation facility. Vergence functions measured the near point of convergence, vergence facility, and distance fusional vergence at break and recovery point. Ocular motor alignment was not statistically significant between both groups. Athletes had a statistically significant amplitude of accommodation for both the right eye (t=2.30, P=0.02) and the left eye (t=1.99, P=0.05). Conversely, non-athletes had better accommodation facility (t=-2.54, P=0.01) and near point of convergence (t=4.39, P<0.001) when compared to athletes. Vergence facility was found to be better among athletes (t=2.47, P=0.01). Nevertheless, non-athletes were significantly better for both distance negative and positive fusional vergence. CONCLUSION Although the findings are still inconclusive as to whether athletes had superior visual skills as compared to non-athletes, it remains important to identify and elucidate the key visual skills needed by athletes in order for them to achieve higher performance in their sports. PMID:28944208

  8. Visual analytics of inherently noisy crowdsourced data on ultra high resolution displays

    NASA Astrophysics Data System (ADS)

    Huynh, Andrew; Ponto, Kevin; Lin, Albert Yu-Min; Kuester, Falko

    The increasing prevalence of distributed human microtasking, crowdsourcing, has followed the exponential increase in data collection capabilities. The large scale and distributed nature of these microtasks produce overwhelming amounts of information that is inherently noisy due to the nature of human input. Furthermore, these inputs create a constantly changing dataset with additional information added on a daily basis. Methods to quickly visualize, filter, and understand this information over temporal and geospatial constraints is key to the success of crowdsourcing. This paper present novel methods to visually analyze geospatial data collected through crowdsourcing on top of remote sensing satellite imagery. An ultra high resolution tiled display system is used to explore the relationship between human and satellite remote sensing data at scale. A case study is provided that evaluates the presented technique in the context of an archaeological field expedition. A team in the field communicated in real-time with and was guided by researchers in the remote visual analytics laboratory, swiftly sifting through incoming crowdsourced data to identify target locations that were identified as viable archaeological sites.

  9. Non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison of imaging with the short tau inversion recovery method and the chemical shift selective method.

    PubMed

    Shimizu, Hironori; Isoda, Hiroyoshi; Ohno, Tsuyoshi; Yamashita, Rikiya; Kawahara, Seiya; Furuta, Akihiro; Fujimoto, Koji; Kido, Aki; Kusahara, Hiroshi; Togashi, Kaori

    2015-01-01

    To compare and evaluate images of non-contrast enhanced magnetic resonance (MR) portography and hepatic venography acquired with two different fat suppression methods, the chemical shift selective (CHESS) method and short tau inversion recovery (STIR) method. Twenty-two healthy volunteers were examined using respiratory-triggered three-dimensional true steady-state free-precession with two time-spatial labeling inversion pulses. The CHESS or STIR methods were used for fat suppression. The relative signal-to-noise ratio and contrast-to-noise ratio (CNR) were quantified, and the quality of visualization was scored. Image acquisition was successfully conducted in all volunteers. The STIR method significantly improved the CNRs of MR portography and hepatic venography. The image quality scores of main portal vein and right portal vein were higher with the STIR method, but there were no significant differences. The image quality scores of right hepatic vein, middle hepatic vein, and left hepatic vein (LHV) were all higher, and the visualization of LHV was significantly better (p<0.05). The STIR method contributes to further suppression of the background signal and improves visualization of the portal and hepatic veins. The results support using non-contrast-enhanced MR portography and hepatic venography in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity

    PubMed Central

    Zhu, X; Ye, H; He, W; Yang, J; Dai, J; Lu, Y

    2017-01-01

    Purpose To explore the objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity. Methods We enrolled 130 cataract patients whose best-corrected visual acuity (BCVA) was 20/40 or better preoperatively. Objective visual functions were evaluated with a KR-1W analyzer before and at 1 month after cataract surgery. Results The nuclear (N), cortical (C), and N+C groups had very high preoperative ocular and internal total high-order aberrations (HOAs), coma, and abnormal spherical aberrations. At 1 month after cataract surgery, in addition to the remarkable increase of both uncorrected visual acuity and BCVA, both ocular and internal HOAs in the three groups decreased significantly after cataract surgery (all P<0.05). Point spread function and modulation transfer functions were also improved significantly in these patients (all P<0.05). Conclusions The objective functional vision of patients with 20/40 or better preoperative BCVA improved significantly after cataract surgery. This finding shows that the arbitrary threshold of BCVA worse than 20/40 in China cannot always be used to determine who will benefit from cataract surgery. PMID:27858933

  11. Utility values in the visually impaired: comparing time-trade off and VisQoL.

    PubMed

    Gothwal, Vijaya K; Bagga, Deepak K

    2013-08-01

    Visual impairment (VI) negatively affects quality of life (QoL). Utilities represent a way of measuring the QoL impact associated with a particular health state, like VI, and are also useful in economic evaluations of health care interventions. Utilities can be determined either directly or indirectly. Here we determine whether the Vision and Quality of Life Index, VisQoL (indirect approach), is acceptable to use in patients with VI in an urban setting in South India; whether the VisQoL utility values, derived from an Australian sample of both visually impaired and normally sighted participants, demonstrate agreement (if any) with direct utilities, determined by time trade-off (TTO), from visually impaired South Indian patients; and determine the relationship between utilities and self-reported visual disability. Three hundred forty-nine adults with VI were administered the two-item TTO item, six-item VisQoL, and the 16-item Andhra Pradesh Eye Disease-Visual Function Questionnaire (APEDS-VFQ) in a face-to-face interview. The VisQoL utilities were derived from the utility scoring algorithm. Rasch-scaled scores of the APEDS-VFQ were obtained using the conversion scores sheets. Agreement between TTO and utilities VisQoL was assessed using the Bland-Altman method. All participants (response rate, 100%) completed the VisQoL as compared with 72% for the TTO. There was no statistically significant difference in the mean utilities from the two methods (0.65 ± 0.31 by TTO vs. 0.66 ± 0.27 by VisQoL, p = 0.67). However, the 95% limits of agreement on the Bland-Altman plot were wide (-0.65, 0.67), implying a lack of agreement between the methods. The VisQoL relates relatively strongly with APEDS-VFQ as compared with TTO (TTO vs. APEDS-VFQ, r = -0.23, VisQoL vs. APEDS-VFQ, r = -0.66, z = -6.70; p < 0.001 for both). Older participants, female, and those with less than 12 years of education had lower utilities. The direct (TTO) and indirect (VisQoL) methods of utility evaluation tend to disagree in our patients with VI. Given the high completion rates of the VisQoL as compared with the TTO, the VisQoL may be a suitable alternative for utility assessment in an Indian population.

  12. Infuence of Averaging Method on the Evaluation of a Coastal Ocean Color Event on the U.S. Northeast Coast

    NASA Technical Reports Server (NTRS)

    Acker, James G.; Uz, Stephanie Schollaert; Shen, Suhung; Leptoukh, Gregory G.

    2010-01-01

    Application of appropriate spatial averaging techniques is crucial to correct evaluation of ocean color radiometric data, due to the common log-normal or mixed log-normal distribution of these data. Averaging method is particularly crucial for data acquired in coastal regions. The effect of averaging method was markedly demonstrated for a precipitation-driven event on the U.S. Northeast coast in October-November 2005, which resulted in export of high concentrations of riverine colored dissolved organic matter (CDOM) to New York and New Jersey coastal waters over a period of several days. Use of the arithmetic mean averaging method created an inaccurate representation of the magnitude of this event in SeaWiFS global mapped chl a data, causing it to be visualized as a very large chl a anomaly. The apparent chl a anomaly was enhanced by the known incomplete discrimination of CDOM and phytoplankton chlorophyll in SeaWiFS data; other data sources enable an improved characterization. Analysis using the geometric mean averaging method did not indicate this event to be statistically anomalous. Our results predicate the necessity of providing the geometric mean averaging method for ocean color radiometric data in the Goddard Earth Sciences DISC Interactive Online Visualization ANd aNalysis Infrastructure (Giovanni).

  13. Quantitative impact characterization of aeronautical CFRP materials with non-destructive testing methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefel, Denis, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Stoessel, Rainer, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Grosse, Christian, E-mail: Grosse@tum.de

    2015-03-31

    In recent years, an increasing number of safety-relevant structures are designed and manufactured from carbon fiber reinforced polymers (CFRP) in order to reduce weight of airplanes by taking the advantage of their specific strength into account. Non-destructive testing (NDT) methods for quantitative defect analysis of damages are liquid- or air-coupled ultrasonic testing (UT), phased array ultrasonic techniques, and active thermography (IR). The advantage of these testing methods is the applicability on large areas. However, their quantitative information is often limited on impact localization and size. In addition to these techniques, Airbus Group Innovations operates a micro x-ray computed tomography (μ-XCT)more » system, which was developed for CFRP characterization. It is an open system which allows different kinds of acquisition, reconstruction, and data evaluation. One main advantage of this μ-XCT system is its high resolution with 3-dimensional analysis and visualization opportunities, which enables to gain important quantitative information for composite part design and stress analysis. Within this study, different NDT methods will be compared at CFRP samples with specified artificial impact damages. The results can be used to select the most suitable NDT-method for specific application cases. Furthermore, novel evaluation and visualization methods for impact analyzes are developed and will be presented.« less

  14. A rating system for the esthetics of bridges.

    DOT National Transportation Integrated Search

    1980-01-01

    There is a need for a tangible way to evaluate the esthetic or visual characteristics of bridges. This report describes such a method based on a numerical experiential rating scale of -10 to +10. Negative values represent unpleasurable responses; pos...

  15. User-Centered Evaluation of Visual Analytics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scholtz, Jean C.

    Visual analytics systems are becoming very popular. More domains now use interactive visualizations to analyze the ever-increasing amount and heterogeneity of data. More novel visualizations are being developed for more tasks and users. We need to ensure that these systems can be evaluated to determine that they are both useful and usable. A user-centered evaluation for visual analytics needs to be developed for these systems. While many of the typical human-computer interaction (HCI) evaluation methodologies can be applied as is, others will need modification. Additionally, new functionality in visual analytics systems needs new evaluation methodologies. There is a difference betweenmore » usability evaluations and user-centered evaluations. Usability looks at the efficiency, effectiveness, and user satisfaction of users carrying out tasks with software applications. User-centered evaluation looks more specifically at the utility provided to the users by the software. This is reflected in the evaluations done and in the metrics used. In the visual analytics domain this is very challenging as users are most likely experts in a particular domain, the tasks they do are often not well defined, the software they use needs to support large amounts of different kinds of data, and often the tasks last for months. These difficulties are discussed more in the section on User-centered Evaluation. Our goal is to provide a discussion of user-centered evaluation practices for visual analytics, including existing practices that can be carried out and new methodologies and metrics that need to be developed and agreed upon by the visual analytics community. The material provided here should be of use for both researchers and practitioners in the field of visual analytics. Researchers and practitioners in HCI and interested in visual analytics will find this information useful as well as a discussion on changes that need to be made to current HCI practices to make them more suitable to visual analytics. A history of analysis and analysis techniques and problems is provided as well as an introduction to user-centered evaluation and various evaluation techniques for readers from different disciplines. The understanding of these techniques is imperative if we wish to support analysis in the visual analytics software we develop. Currently the evaluations that are conducted and published for visual analytics software are very informal and consist mainly of comments from users or potential users. Our goal is to help researchers in visual analytics to conduct more formal user-centered evaluations. While these are time-consuming and expensive to carryout, the outcomes of these studies will have a defining impact on the field of visual analytics and help point the direction for future features and visualizations to incorporate. While many researchers view work in user-centered evaluation as a less-than-exciting area to work, the opposite is true. First of all, the goal is user-centered evaluation is to help visual analytics software developers, researchers, and designers improve their solutions and discover creative ways to better accommodate their users. Working with the users is extremely rewarding as well. While we use the term “users” in almost all situations there are a wide variety of users that all need to be accommodated. Moreover, the domains that use visual analytics are varied and expanding. Just understanding the complexities of a number of these domains is exciting. Researchers are trying out different visualizations and interactions as well. And of course, the size and variety of data are expanding rapidly. User-centered evaluation in this context is rapidly changing. There are no standard processes and metrics and thus those of us working on user-centered evaluation must be creative in our work with both the users and with the researchers and developers.« less

  16. Uncertainty Footprint: Visualization of Nonuniform Behavior of Iterative Algorithms Applied to 4D Cell Tracking

    PubMed Central

    Wan, Y.; Hansen, C.

    2018-01-01

    Research on microscopy data from developing biological samples usually requires tracking individual cells over time. When cells are three-dimensionally and densely packed in a time-dependent scan of volumes, tracking results can become unreliable and uncertain. Not only are cell segmentation results often inaccurate to start with, but it also lacks a simple method to evaluate the tracking outcome. Previous cell tracking methods have been validated against benchmark data from real scans or artificial data, whose ground truth results are established by manual work or simulation. However, the wide variety of real-world data makes an exhaustive validation impossible. Established cell tracking tools often fail on new data, whose issues are also difficult to diagnose with only manual examinations. Therefore, data-independent tracking evaluation methods are desired for an explosion of microscopy data with increasing scale and resolution. In this paper, we propose the uncertainty footprint, an uncertainty quantification and visualization technique that examines nonuniformity at local convergence for an iterative evaluation process on a spatial domain supported by partially overlapping bases. We demonstrate that the patterns revealed by the uncertainty footprint indicate data processing quality in two algorithms from a typical cell tracking workflow – cell identification and association. A detailed analysis of the patterns further allows us to diagnose issues and design methods for improvements. A 4D cell tracking workflow equipped with the uncertainty footprint is capable of self diagnosis and correction for a higher accuracy than previous methods whose evaluation is limited by manual examinations. PMID:29456279

  17. WELDSMART: A vision-based expert system for quality control

    NASA Technical Reports Server (NTRS)

    Andersen, Kristinn; Barnett, Robert Joel; Springfield, James F.; Cook, George E.

    1992-01-01

    This work was aimed at exploring means for utilizing computer technology in quality inspection and evaluation. Inspection of metallic welds was selected as the main application for this development and primary emphasis was placed on visual inspection, as opposed to other inspection methods, such as radiographic techniques. Emphasis was placed on methodologies with the potential for use in real-time quality control systems. Because quality evaluation is somewhat subjective, despite various efforts to classify discontinuities and standardize inspection methods, the task of using a computer for both inspection and evaluation was not trivial. The work started out with a review of the various inspection techniques that are used for quality control in welding. Among other observations from this review was the finding that most weld defects result in abnormalities that may be seen by visual inspection. This supports the approach of emphasizing visual inspection for this work. Quality control consists of two phases: (1) identification of weld discontinuities (some of which may be severe enough to be classified as defects), and (2) assessment or evaluation of the weld based on the observed discontinuities. Usually the latter phase results in a pass/fail judgement for the inspected piece. It is the conclusion of this work that the first of the above tasks, identification of discontinuities, is the most challenging one. It calls for sophisticated image processing and image analysis techniques, and frequently ad hoc methods have to be developed to identify specific features in the weld image. The difficulty of this task is generally not due to limited computing power. In most cases it was found that a modest personal computer or workstation could carry out most computations in a reasonably short time period. Rather, the algorithms and methods necessary for identifying weld discontinuities were in some cases limited. The fact that specific techniques were finally developed and successfully demosntrated to work illustrates that the general approach taken here appears to be promising for commercial development of computerized quality inspection systems. Inspection based on these techniques may be used to supplement or substitute more elaborate inspection methods, such as x-ray inspections.

  18. Accurate micro-computed tomography imaging of pore spaces in collagen-based scaffold.

    PubMed

    Zidek, Jan; Vojtova, Lucy; Abdel-Mohsen, A M; Chmelik, Jiri; Zikmund, Tomas; Brtnikova, Jana; Jakubicek, Roman; Zubal, Lukas; Jan, Jiri; Kaiser, Jozef

    2016-06-01

    In this work we have used X-ray micro-computed tomography (μCT) as a method to observe the morphology of 3D porous pure collagen and collagen-composite scaffolds useful in tissue engineering. Two aspects of visualizations were taken into consideration: improvement of the scan and investigation of its sensitivity to the scan parameters. Due to the low material density some parts of collagen scaffolds are invisible in a μCT scan. Therefore, here we present different contrast agents, which increase the contrast of the scanned biopolymeric sample for μCT visualization. The increase of contrast of collagenous scaffolds was performed with ceramic hydroxyapatite microparticles (HAp), silver ions (Ag(+)) and silver nanoparticles (Ag-NPs). Since a relatively small change in imaging parameters (e.g. in 3D volume rendering, threshold value and μCT acquisition conditions) leads to a completely different visualized pattern, we have optimized these parameters to obtain the most realistic picture for visual and qualitative evaluation of the biopolymeric scaffold. Moreover, scaffold images were stereoscopically visualized in order to better see the 3D biopolymer composite scaffold morphology. However, the optimized visualization has some discontinuities in zoomed view, which can be problematic for further analysis of interconnected pores by commonly used numerical methods. Therefore, we applied the locally adaptive method to solve discontinuities issue. The combination of contrast agent and imaging techniques presented in this paper help us to better understand the structure and morphology of the biopolymeric scaffold that is crucial in the design of new biomaterials useful in tissue engineering.

  19. Dual-Tree Complex Wavelet Transform and Image Block Residual-Based Multi-Focus Image Fusion in Visual Sensor Networks

    PubMed Central

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-01-01

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs. PMID:25587878

  20. Dual-tree complex wavelet transform and image block residual-based multi-focus image fusion in visual sensor networks.

    PubMed

    Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan

    2014-11-26

    This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs.

  1. Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience

    PubMed Central

    Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan

    2016-01-01

    Objective: Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. Material and Methods: IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Results: Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2–3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. Conclusion: According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible. PMID:26985159

  2. Comparing the Impact of Refractive and Non-Refractive Vision Loss on Functioning and Disability: The Salisbury Eye Evaluation

    PubMed Central

    Zebardast, Nazlee; Swenor, Bonnielin K.; van Landingham, Suzanne W.; Massof, Robert W.; Munoz, Beatriz; West, Sheila K.; Ramulu, Pradeep Y.

    2015-01-01

    Purpose To compare the effects of uncorrected refractive error (URE) and non-refractive visual impairment (VI) on performance and disability measures. Design Cross-sectional population-based study. Participants 2469 individuals with binocular presenting visual acuity (PVA) of 20/80 or better who participated in the first round of the Salisbury Eye Evaluation study. Methods URE was defined as binocular PVA of 20/30 or worse, improving to better than 20/30 with subjective refraction. VI was defined as post-refraction binocular best corrected visual acuity (BCVA) of 20/30 or worse. The visual acuity decrement attributable to VI was calculated as the difference between BCVA and 20/30 while that due to URE was taken as the difference between PVA and BCVA. Multivariable regression analyses were used to assess the disability impact of 1) vision status (VI, URE, or normal vision) using the group with normal vision as reference, and 2) a one-line decrement in acuity due to VI or URE. Main Outcome Measures Objective measures of visual function were obtained from timed performance of mobility and near vision tasks, self-reported driving cessation, and self-reported visual difficulty measured by the Activities of Daily Vision (ADV) scale. ADV responses were analyzed using Rasch analysis to determine visual ability. Results Compared to individuals with normal vision, subjects with VI (n=191) had significantly poorer objective and subjective visual functioning in all metrics examined (p<0.05) while subjects with URE (n=132) demonstrated slower walking speeds, slower near task performance, more frequent driving cessation and lower ADV scores (p<0.05), but did not demonstrate slower stair climbing or descent speed. For all functional metrics evaluated, the impact of VI was greater than the impact of URE. The impact of a one-line VA decrement due to VI was associated with greater deficits in mobility measures and driving cessation when compared to a one-line VA decrement due to URE. Conclusions VI is associated with greater disability than URE across a wide variety of functional measures, even in analyses adjusting for the severity of vision loss. Refractive and non-refractive vision loss should be distinguished in studies evaluating visual disability, and should be understood to have differing consequences. PMID:25813453

  3. Choice of Grating Orientation for Evaluation of Peripheral Vision

    PubMed Central

    Venkataraman, Abinaya Priya; Winter, Simon; Rosén, Robert; Lundström, Linda

    2016-01-01

    ABSTRACT Purpose Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field. Methods Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations. Results For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity. Conclusions Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation. PMID:26889822

  4. High pitch third generation dual-source CT: Coronary and Cardiac Visualization on Routine Chest CT

    PubMed Central

    Sandfort, Veit; Ahlman, Mark; Jones, Elizabeth; Selwaness, Mariana; Chen, Marcus; Folio, Les; Bluemke, David A.

    2016-01-01

    Background Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. Objectives To evaluate myocardial and coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). Methods Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. Results 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p<0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p<0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p<0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p <0.01 for both) with comparable image noise (p=0.43). Conclusion Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications. PMID:27133589

  5. Psycho-physiological effects of visual artifacts by stereoscopic display systems

    NASA Astrophysics Data System (ADS)

    Kim, Sanghyun; Yoshitake, Junki; Morikawa, Hiroyuki; Kawai, Takashi; Yamada, Osamu; Iguchi, Akihiko

    2011-03-01

    The methods available for delivering stereoscopic (3D) display using glasses can be classified as time-multiplexing and spatial-multiplexing. With both methods, intrinsic visual artifacts result from the generation of the 3D image pair on a flat panel display device. In the case of the time-multiplexing method, an observer perceives three artifacts: flicker, the Mach-Dvorak effect, and a phantom array. These only occur under certain conditions, with flicker appearing in any conditions, the Mach-Dvorak effect during smooth pursuit eye movements (SPM), and a phantom array during saccadic eye movements (saccade). With spatial-multiplexing, the artifacts are temporal-parallax (due to the interlaced video signal), binocular rivalry, and reduced spatial resolution. These artifacts are considered one of the major impediments to the safety and comfort of 3D display users. In this study, the implications of the artifacts for the safety and comfort are evaluated by examining the psychological changes they cause through subjective symptoms of fatigue and the depth sensation. Physiological changes are also measured as objective responses based on analysis of heart and brain activation by visual artifacts. Further, to understand the characteristics of each artifact and the combined effects of the artifacts, four experimental conditions are developed and tested. The results show that perception of artifacts differs according to the visual environment and the display method. Furthermore visual fatigue and the depth sensation are influenced by the individual characteristics of each artifact. Similarly, heart rate variability and regional cerebral oxygenation changes by perception of artifacts in conditions.

  6. [Multifocal visual electrophysiology in visual function evaluation].

    PubMed

    Peng, Shu-Ya; Chen, Jie-Min; Liu, Rui-Jue; Zhou, Shu; Liu, Dong-Mei; Xia, Wen-Tao

    2013-08-01

    Multifocal visual electrophysiology, consisting of multifocal electroretinography (mfERG) and multifocal visual evoked potential (mfVEP), can objectively evaluate retina function and retina-cortical conduction pathway status by stimulating many local retinal regions and obtaining each local response simultaneously. Having many advantages such as short testing time and high sensitivity, it has been widely used in clinical ophthalmology, especially in the diagnosis of retinal disease and glaucoma. It is a new objective technique in clinical forensic medicine involving visual function evaluation of ocular trauma in particular. This article summarizes the way of stimulation, the position of electrodes, the way of analysis, the visual function evaluation of mfERG and mfVEP, and discussed the value of multifocal visual electrophysiology in forensic medicine.

  7. Validation of a Spectral Method for Quantitative Measurement of Color in Protein Drug Solutions.

    PubMed

    Yin, Jian; Swartz, Trevor E; Zhang, Jian; Patapoff, Thomas W; Chen, Bartolo; Marhoul, Joseph; Shih, Norman; Kabakoff, Bruce; Rahimi, Kimia

    2016-01-01

    A quantitative spectral method has been developed to precisely measure the color of protein solutions. In this method, a spectrophotometer is utilized for capturing the visible absorption spectrum of a protein solution, which can then be converted to color values (L*a*b*) that represent human perception of color in a quantitative three-dimensional space. These quantitative values (L*a*b*) allow for calculating the best match of a sample's color to a European Pharmacopoeia reference color solution. In order to qualify this instrument and assay for use in clinical quality control, a technical assessment was conducted to evaluate the assay suitability and precision. Setting acceptance criteria for this study required development and implementation of a unique statistical method for assessing precision in 3-dimensional space. Different instruments, cuvettes, protein solutions, and analysts were compared in this study. The instrument accuracy, repeatability, and assay precision were determined. The instrument and assay are found suitable for use in assessing color of drug substances and drug products and is comparable to the current European Pharmacopoeia visual assessment method. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. In this study, we established a statistical method for assessing precision in 3-dimensional space and demonstrated that the quantitative spectral method is comparable with respect to precision and accuracy to the current European Pharmacopoeia visual assessment method. © PDA, Inc. 2016.

  8. Visual functions and disability in diabetic retinopathy patients

    PubMed Central

    Shrestha, Gauri Shankar; Kaiti, Raju

    2013-01-01

    Purpose This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. Method A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. Result The majority of subjects (42.1%) were of the age group 60–70 years. Best corrected visual acuity was found to be 0.73 ± 0.2 in the better eye and 0.93 ± 0.27 in the worse eye, which was significantly different at p = 0.002. Visual disability scores were significantly higher for legibility of letters (1.2 ± 0.3) and sentences (1.4 ± 0.4), and least for clothing (0.7 ± 0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Conclusion Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. PMID:24646899

  9. Implementing novel imaging methods for improved diagnosis of disorder of consciousness patients.

    PubMed

    Bick, Atira S; Leker, Ronen R; Ben-Hur, Tamir; Levin, Netta

    2013-11-15

    The clinical evaluation of consciousness in disorder of consciousness (DOC) patients based on their exhibited behavior is difficult and remains erroneous in many cases. Recent studies demonstrated different levels of stimulus processing as well as evidence of some level of awareness in sub-groups of these patients. The aim of the current study was to examine the plausibility and challenges of implementing a clinical service for evaluation of consciousness level in DOC patients. Eleven Patients (ages 11-67) diagnosed as being in vegetative or minimal conscious states were included. Functional MRI evaluations included auditory, language, voice familiarity, imagery, and visual tests. In 9 patients auditory-related activation was found, however only in 5 of the subjects was differential activation found for language. Six patients exhibited differential response to their own name. In three patients a response to visual stimuli was identified. In one patient the auditory and linguistic systems were clearly activated in a hierarchical pattern, and moreover willful modulation of brain activity was identified in the imagery test. We discuss the importance of using a wide battery of tests, the difference between our clinical cohort and previous publications, as well as the challenges of clinically implementing this method. Translating novel imaging methods into the clinical evaluation of DOC patients is essential for better diagnosis and may encourage treatment development. © 2013 Elsevier B.V. All rights reserved.

  10. An enhanced functional ability questionnaire (faVIQ) to measure the impact of rehabilitation services on the visually impaired

    PubMed Central

    Wolffsohn, James Stuart; Jackson, Jonathan; Hunt, Olivia Anne; Cottriall, Charles; Lindsay, Jennifer; Gilmour, Richard; Sinclair, Anne; Harper, Robert

    2014-01-01

    AIM To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. METHODS Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual impairment. RESULTS Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. CONCLUSION The faVIQ allows sensitive assessment of quality-of-life in the visually impaired and should support studies which evaluate the effectiveness of low vision rehabilitation services. PMID:24634868

  11. Preservation of three-dimensional spatial structure in the gut microbiome.

    PubMed

    Hasegawa, Yuko; Mark Welch, Jessica L; Rossetti, Blair J; Borisy, Gary G

    2017-01-01

    Preservation of three-dimensional structure in the gut is necessary in order to analyze the spatial organization of the gut microbiota and gut luminal contents. In this study, we evaluated preparation methods for mouse gut with the goal of preserving micron-scale spatial structure while performing fluorescence imaging assays. Our evaluation of embedding methods showed that commonly used media such as Tissue-Tek Optimal Cutting Temperature (OCT) compound, paraffin, and polyester waxes resulted in redistribution of luminal contents. By contrast, a hydrophilic methacrylate resin, Technovit H8100, preserved three-dimensional organization. Our mouse intestinal preparation protocol optimized using the Technovit H8100 embedding method was compatible with microbial fluorescence in situ hybridization (FISH) and other labeling techniques, including immunostaining and staining with both wheat germ agglutinin (WGA) and 4', 6-diamidino-2-phenylindole (DAPI). Mucus could be visualized whether the sample was fixed with paraformaldehyde (PFA) or with Carnoy's fixative. The protocol optimized in this study enabled simultaneous visualization of micron-scale spatial patterns formed by microbial cells in the mouse intestines along with biogeographical landmarks such as host-derived mucus and food particles.

  12. Visual rating method and tensor-based morphometry in the diagnosis of mild cognitive impairment and Alzheimer's disease: a comparative magnetic resonance imaging study.

    PubMed

    Tuokkola, Terhi; Koikkalainen, Juha; Parkkola, Riitta; Karrasch, Mira; Lötjönen, Jyrki; Rinne, Juha O

    2016-03-01

    Atrophy of the medial temporal lobe (MTL) is the main structural magnetic resonance imaging (MRI) finding in the brain of patients with Alzheimer's disease (AD). However, evaluating the degree of atrophy is still demanding. The visual rating method (VRM) was compared with multi-template tensor-based morphometry (TBM), in terms of its efficacy in diagnosing of mild cognitive impairment (MCI) and AD. Forty-seven patients with MCI, 80 patients with AD and 84 controls were studied. TBM seems to be more sensitive than VRM at the early stage of dementia in the areas of MTL and ventricles. The methods were equally good in distinguishing controls and the MCI group from the AD group. At the frontal areas TBM was better than VRM in all comparisons. A user-friendly VRM is still useful for the clinical evaluation of MCI patients, but multi-template TBM is more sensitive for diagnosing the early stages of dementia. However, TBM is currently too demanding to use for daily clinical work. © The Foundation Acta Radiologica 2015.

  13. Cartwheel projections of segmented pulmonary vasculature for the detection of pulmonary embolism

    NASA Astrophysics Data System (ADS)

    Kiraly, Atilla P.; Naidich, David P.; Novak, Carol L.

    2005-04-01

    Pulmonary embolism (PE) detection via contrast-enhanced computed tomography (CT) images is an increasingly important topic of research. Accurate identification of PE is of critical importance in determining the need for further treatment. However, current multi-slice CT scanners provide datasets typically containing 600 or more images per patient, making it desirable to have a visualization method to help radiologists focus directly on potential candidates that might otherwise have been overlooked. This is especially important when assessing the ability of CT to identify smaller, sub-segmental emboli. We propose a cartwheel projection approach to PE visualization that computes slab projections of the original data aided by vessel segmentation. Previous research on slab visualization for PE has utilized the entire volumetric dataset, requiring thin slabs and necessitating the use of maximum intensity projection (MIP). Our use of segmentation within the projection computation allows the use of thicker slabs than previous methods, as well as the ability to employ visualization variations that are only possible with segmentation. Following automatic segmentation of the pulmonary vessels, slabs may be rotated around the X-, Y- or Z-axis. These slabs are rendered by preferentially using voxels within the lung vessels. This effectively eliminates distracting information not relevant to diagnosis, lessening both the chance of overlooking a subtle embolus and minimizing time on spent evaluating false positives. The ability to employ thicker slabs means fewer images need to be evaluated, yielding a more efficient workflow.

  14. Hybrid region merging method for segmentation of high-resolution remote sensing images

    NASA Astrophysics Data System (ADS)

    Zhang, Xueliang; Xiao, Pengfeng; Feng, Xuezhi; Wang, Jiangeng; Wang, Zuo

    2014-12-01

    Image segmentation remains a challenging problem for object-based image analysis. In this paper, a hybrid region merging (HRM) method is proposed to segment high-resolution remote sensing images. HRM integrates the advantages of global-oriented and local-oriented region merging strategies into a unified framework. The globally most-similar pair of regions is used to determine the starting point of a growing region, which provides an elegant way to avoid the problem of starting point assignment and to enhance the optimization ability for local-oriented region merging. During the region growing procedure, the merging iterations are constrained within the local vicinity, so that the segmentation is accelerated and can reflect the local context, as compared with the global-oriented method. A set of high-resolution remote sensing images is used to test the effectiveness of the HRM method, and three region-based remote sensing image segmentation methods are adopted for comparison, including the hierarchical stepwise optimization (HSWO) method, the local-mutual best region merging (LMM) method, and the multiresolution segmentation (MRS) method embedded in eCognition Developer software. Both the supervised evaluation and visual assessment show that HRM performs better than HSWO and LMM by combining both their advantages. The segmentation results of HRM and MRS are visually comparable, but HRM can describe objects as single regions better than MRS, and the supervised and unsupervised evaluation results further prove the superiority of HRM.

  15. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-connected visual impairment of only one eye. Subject to the provisions of 38 CFR 3.383(a), if visual impairment of only one eye is service-connected, the visual acuity of the other eye will be considered to be... visual impairment of one eye. The evaluation for visual impairment of one eye must not exceed 30 percent...

  16. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-connected visual impairment of only one eye. Subject to the provisions of 38 CFR 3.383(a), if visual impairment of only one eye is service-connected, the visual acuity of the other eye will be considered to be... visual impairment of one eye. The evaluation for visual impairment of one eye must not exceed 30 percent...

  17. Comparison of Germination and Viability Tests for Southern Hardwood Seed

    Treesearch

    F. T. Bonner; J. L. Gammage

    1967-01-01

    This paper summarizes a 3-year evaluation of 10 methods for testing germinability and viability of the seed of six species of southern hardwood. In five of the methods, the seeds were germinated. In the others, visual, biochemical, or physical properties were the criteria. Cutting tests were best for sweetgum and Nuttall oak seed, while cutting or water germination...

  18. Comparison of four different pain relief methods during hysterosalpingography: A randomized controlled study

    PubMed Central

    Unlu, Bekir Serdar; Yilmazer, Mehmet; Koken, Gulengul; Arioz, Dagistan Tolga; Unlu, Ebru; Baki, Elif Dogan; Kurttay, Cemile; Karacin, Osman

    2015-01-01

    BACKGROUND: Hysterosalpingography (HSG) is the most commonly used method for evaluating the anatomy and patency of the uterine cavity and fallopian tubes, and is an important tool in the evaluation of infertility. The most frequent side effect is the pain associated with the procedure. OBJECTIVES: To evaluate four analgesic methods to determine the most useful method for reducing discomfort associated with HSG. METHODS: In the present prospective study, 75 patients undergoing HSG for evaluation of infertility were randomly assigned to four groups: 550 mg of a nonsteroidal anti-inflammatory drug (NSAID) (group 1); 550 mg NSAID + paracervical block (group 2); 550 mg NSAID + paracervical analgesic cream (group 3); or 550 mg NSAID + intrauterine analgesic instillation (group 4). A visual analogue scale was used to assess the pain perception at five predefined steps. RESULTS: Instillation of the liquids used for HSG was found to be the most painful step of HSG, and this step was where the only significant difference among groups was observed. When comparing visual analogue scale scores, group 2 and group 3 reported significantly less pain than the other groups. Group 1 reported significantly higher mean (± SD) scores (7.2±1.6) compared with groups 2 and 3 (4.7±2.5 and 3.8±2.4, respectively) (P<0.001). In addition, group 2 reported significantly less pain than group 4 (4.7±2.5 versus 6.7±1.8, respectively) (P<0.02). CONCLUSIONS: For effective pain relief during HSG, in addition to 550 mg NSAID, local application of lidocaine cream to the posterior fornix of the cervix uteri and paracervical lidocaine injection into the cervix uteri appear to be the most effective methods. PMID:25848848

  19. Video conference quality assessment based on cooperative sensing of video and audio

    NASA Astrophysics Data System (ADS)

    Wang, Junxi; Chen, Jialin; Tian, Xin; Zhou, Cheng; Zhou, Zheng; Ye, Lu

    2015-12-01

    This paper presents a method to video conference quality assessment, which is based on cooperative sensing of video and audio. In this method, a proposed video quality evaluation method is used to assess the video frame quality. The video frame is divided into noise image and filtered image by the bilateral filters. It is similar to the characteristic of human visual, which could also be seen as a low-pass filtering. The audio frames are evaluated by the PEAQ algorithm. The two results are integrated to evaluate the video conference quality. A video conference database is built to test the performance of the proposed method. It could be found that the objective results correlate well with MOS. Then we can conclude that the proposed method is efficiency in assessing video conference quality.

  20. COMPUTERIZED EXPERT SYSTEM FOR EVALUATION OF AUTOMATED VISUAL FIELDS FROM THE ISCHEMIC OPTIC NEUROPATHY DECOMPRESSION TRIAL: METHODS, BASELINE FIELDS, AND SIX-MONTH LONGITUDINAL FOLLOW-UP

    PubMed Central

    Feldon, Steven E

    2004-01-01

    ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764

  1. iTTVis: Interactive Visualization of Table Tennis Data.

    PubMed

    Wu, Yingcai; Lan, Ji; Shu, Xinhuan; Ji, Chenyang; Zhao, Kejian; Wang, Jiachen; Zhang, Hui

    2018-01-01

    The rapid development of information technology paved the way for the recording of fine-grained data, such as stroke techniques and stroke placements, during a table tennis match. This data recording creates opportunities to analyze and evaluate matches from new perspectives. Nevertheless, the increasingly complex data poses a significant challenge to make sense of and gain insights into. Analysts usually employ tedious and cumbersome methods which are limited to watching videos and reading statistical tables. However, existing sports visualization methods cannot be applied to visualizing table tennis competitions due to different competition rules and particular data attributes. In this work, we collaborate with data analysts to understand and characterize the sophisticated domain problem of analysis of table tennis data. We propose iTTVis, a novel interactive table tennis visualization system, which to our knowledge, is the first visual analysis system for analyzing and exploring table tennis data. iTTVis provides a holistic visualization of an entire match from three main perspectives, namely, time-oriented, statistical, and tactical analyses. The proposed system with several well-coordinated views not only supports correlation identification through statistics and pattern detection of tactics with a score timeline but also allows cross analysis to gain insights. Data analysts have obtained several new insights by using iTTVis. The effectiveness and usability of the proposed system are demonstrated with four case studies.

  2. CT method for visualization of the appendix using a fixed oral dosage of diatrizoate--clinical experience in 525 cases.

    PubMed

    Giuliano, Vincenzo; Giuliano, Concetta; Pinto, Fabio; Scaglione, Mariano

    2005-07-01

    The purpose of this study is to determine if focused CT examinations of the pelvis, utilizing fixed oral dosage of diatrizoate contrast media, improve overall reader confidence in visualization of the appendix. Five hundred and twenty-five patients referred for, rule out appendicitis, evaluations underwent focused CT examinations of the pelvis following fixed oral dosage of diatrizoate contrast media. A five-point scale was used to assess the effect of contrast enhancement of the distal small bowel, cecum, and appendix on overall reader confidence, and subsequent visualization of the appendix. Bowel preparation was ideal in 504 of 525 (96%) patients. Enhanced supine CT images following oral administration of fixed dosage of diatrizoate had consistently good scores for reader confidence for bowel opacification (4.8+/-0.1, P<0.005) and visualization of the appendix (3.7+/-0.1, P<0.005), at 50 min following oral contrast administration. This method improved visualization of the normal appendix in 446 of 504 (88%) patients, with a specificity of 99%. In a patients meeting CT criteria for appendicitis, 21 of 21 (100%) patients were proven at surgery. The use of fixed oral dosage of diatrizoate contrast media resulted in good overall reader confidence to visualize the appendix and peri-appendiceal area, in addition to high specificity and rapid transit time.

  3. Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience.

    PubMed

    Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan

    2016-01-01

    Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2-3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible.

  4. R-chie: a web server and R package for visualizing RNA secondary structures

    PubMed Central

    Lai, Daniel; Proctor, Jeff R.; Zhu, Jing Yun A.; Meyer, Irmtraud M.

    2012-01-01

    Visually examining RNA structures can greatly aid in understanding their potential functional roles and in evaluating the performance of structure prediction algorithms. As many functional roles of RNA structures can already be studied given the secondary structure of the RNA, various methods have been devised for visualizing RNA secondary structures. Most of these methods depict a given RNA secondary structure as a planar graph consisting of base-paired stems interconnected by roundish loops. In this article, we present an alternative method of depicting RNA secondary structure as arc diagrams. This is well suited for structures that are difficult or impossible to represent as planar stem-loop diagrams. Arc diagrams can intuitively display pseudo-knotted structures, as well as transient and alternative structural features. In addition, they facilitate the comparison of known and predicted RNA secondary structures. An added benefit is that structure information can be displayed in conjunction with a corresponding multiple sequence alignments, thereby highlighting structure and primary sequence conservation and variation. We have implemented the visualization algorithm as a web server R-chie as well as a corresponding R package called R4RNA, which allows users to run the software locally and across a range of common operating systems. PMID:22434875

  5. Visual exploration and analysis of human-robot interaction rules

    NASA Astrophysics Data System (ADS)

    Zhang, Hui; Boyles, Michael J.

    2013-01-01

    We present a novel interaction paradigm for the visual exploration, manipulation and analysis of human-robot interaction (HRI) rules; our development is implemented using a visual programming interface and exploits key techniques drawn from both information visualization and visual data mining to facilitate the interaction design and knowledge discovery process. HRI is often concerned with manipulations of multi-modal signals, events, and commands that form various kinds of interaction rules. Depicting, manipulating and sharing such design-level information is a compelling challenge. Furthermore, the closed loop between HRI programming and knowledge discovery from empirical data is a relatively long cycle. This, in turn, makes design-level verification nearly impossible to perform in an earlier phase. In our work, we exploit a drag-and-drop user interface and visual languages to support depicting responsive behaviors from social participants when they interact with their partners. For our principal test case of gaze-contingent HRI interfaces, this permits us to program and debug the robots' responsive behaviors through a graphical data-flow chart editor. We exploit additional program manipulation interfaces to provide still further improvement to our programming experience: by simulating the interaction dynamics between a human and a robot behavior model, we allow the researchers to generate, trace and study the perception-action dynamics with a social interaction simulation to verify and refine their designs. Finally, we extend our visual manipulation environment with a visual data-mining tool that allows the user to investigate interesting phenomena such as joint attention and sequential behavioral patterns from multiple multi-modal data streams. We have created instances of HRI interfaces to evaluate and refine our development paradigm. As far as we are aware, this paper reports the first program manipulation paradigm that integrates visual programming interfaces, information visualization, and visual data mining methods to facilitate designing, comprehending, and evaluating HRI interfaces.

  6. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT.

    PubMed

    Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio

    2012-02-01

    Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. In three of six operator pairs and in one of two intra-operator pairs the Kendall τ test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent.

  7. Objective automated quantification of fluorescence signal in histological sections of rat lens.

    PubMed

    Talebizadeh, Nooshin; Hagström, Nanna Zhou; Yu, Zhaohua; Kronschläger, Martin; Söderberg, Per; Wählby, Carolina

    2017-08-01

    Visual quantification and classification of fluorescent signals is the gold standard in microscopy. The purpose of this study was to develop an automated method to delineate cells and to quantify expression of fluorescent signal of biomarkers in each nucleus and cytoplasm of lens epithelial cells in a histological section. A region of interest representing the lens epithelium was manually demarcated in each input image. Thereafter, individual cell nuclei within the region of interest were automatically delineated based on watershed segmentation and thresholding with an algorithm developed in Matlab™. Fluorescence signal was quantified within nuclei, cytoplasms and juxtaposed backgrounds. The classification of cells as labelled or not labelled was based on comparison of the fluorescence signal within cells with local background. The classification rule was thereafter optimized as compared with visual classification of a limited dataset. The performance of the automated classification was evaluated by asking 11 independent blinded observers to classify all cells (n = 395) in one lens image. Time consumed by the automatic algorithm and visual classification of cells was recorded. On an average, 77% of the cells were correctly classified as compared with the majority vote of the visual observers. The average agreement among visual observers was 83%. However, variation among visual observers was high, and agreement between two visual observers was as low as 71% in the worst case. Automated classification was on average 10 times faster than visual scoring. The presented method enables objective and fast detection of lens epithelial cells and quantification of expression of fluorescent signal with an accuracy comparable with the variability among visual observers. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  8. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    NASA Astrophysics Data System (ADS)

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  9. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    PubMed Central

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2017-01-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery. PMID:28943703

  10. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization.

    PubMed

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool ( rdCalib ; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker ® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  11. Visually defining and querying consistent multi-granular clinical temporal abstractions.

    PubMed

    Combi, Carlo; Oliboni, Barbara

    2012-02-01

    The main goal of this work is to propose a framework for the visual specification and query of consistent multi-granular clinical temporal abstractions. We focus on the issue of querying patient clinical information by visually defining and composing temporal abstractions, i.e., high level patterns derived from several time-stamped raw data. In particular, we focus on the visual specification of consistent temporal abstractions with different granularities and on the visual composition of different temporal abstractions for querying clinical databases. Temporal abstractions on clinical data provide a concise and high-level description of temporal raw data, and a suitable way to support decision making. Granularities define partitions on the time line and allow one to represent time and, thus, temporal clinical information at different levels of detail, according to the requirements coming from the represented clinical domain. The visual representation of temporal information has been considered since several years in clinical domains. Proposed visualization techniques must be easy and quick to understand, and could benefit from visual metaphors that do not lead to ambiguous interpretations. Recently, physical metaphors such as strips, springs, weights, and wires have been proposed and evaluated on clinical users for the specification of temporal clinical abstractions. Visual approaches to boolean queries have been considered in the last years and confirmed that the visual support to the specification of complex boolean queries is both an important and difficult research topic. We propose and describe a visual language for the definition of temporal abstractions based on a set of intuitive metaphors (striped wall, plastered wall, brick wall), allowing the clinician to use different granularities. A new algorithm, underlying the visual language, allows the physician to specify only consistent abstractions, i.e., abstractions not containing contradictory conditions on the component abstractions. Moreover, we propose a visual query language where different temporal abstractions can be composed to build complex queries: temporal abstractions are visually connected through the usual logical connectives AND, OR, and NOT. The proposed visual language allows one to simply define temporal abstractions by using intuitive metaphors, and to specify temporal intervals related to abstractions by using different temporal granularities. The physician can interact with the designed and implemented tool by point-and-click selections, and can visually compose queries involving several temporal abstractions. The evaluation of the proposed granularity-related metaphors consisted in two parts: (i) solving 30 interpretation exercises by choosing the correct interpretation of a given screenshot representing a possible scenario, and (ii) solving a complex exercise, by visually specifying through the interface a scenario described only in natural language. The exercises were done by 13 subjects. The percentage of correct answers to the interpretation exercises were slightly different with respect to the considered metaphors (54.4--striped wall, 73.3--plastered wall, 61--brick wall, and 61--no wall), but post hoc statistical analysis on means confirmed that differences were not statistically significant. The result of the user's satisfaction questionnaire related to the evaluation of the proposed granularity-related metaphors ratified that there are no preferences for one of them. The evaluation of the proposed logical notation consisted in two parts: (i) solving five interpretation exercises provided by a screenshot representing a possible scenario and by three different possible interpretations, of which only one was correct, and (ii) solving five exercises, by visually defining through the interface a scenario described only in natural language. Exercises had an increasing difficulty. The evaluation involved a total of 31 subjects. Results related to this evaluation phase confirmed us about the soundness of the proposed solution even in comparison with a well known proposal based on a tabular query form (the only significant difference is that our proposal requires more time for the training phase: 21 min versus 14 min). In this work we have considered the issue of visually composing and querying temporal clinical patient data. In this context we have proposed a visual framework for the specification of consistent temporal abstractions with different granularities and for the visual composition of different temporal abstractions to build (possibly) complex queries on clinical databases. A new algorithm has been proposed to check the consistency of the specified granular abstraction. From the evaluation of the proposed metaphors and interfaces and from the comparison of the visual query language with a well known visual method for boolean queries, the soundness of the overall system has been confirmed; moreover, pros and cons and possible improvements emerged from the comparison of different visual metaphors and solutions. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. A New Dyslexia Reading Method and Visual Correction Position Method.

    PubMed

    Manilla, George T; de Braga, Joe

    2017-01-01

    Pediatricians and educators may interact daily with several dyslexic patients or students. One dyslexic author accidently developed a personal, effective, corrective reading method. Its effectiveness was evaluated in 3 schools. One school utilized 8 demonstration special education students. Over 3 months, one student grew one third year, 3 grew 1 year, and 4 grew 2 years. In another school, 6 sixth-, seventh-, and eighth-grade classroom teachers followed 45 treated dyslexic students. They all excelled and progressed beyond their classroom peers in 4 months. Using cyclovergence upper gaze, dyslexic reading problems disappeared at one of the Positional Reading Arc positions of 30°, 60°, 90°, 120°, or 150° for 10 dyslexics. Positional Reading Arc on 112 students of the second through eighth grades showed words read per minute, reading errors, and comprehension improved. Dyslexia was visually corrected by use of a new reading method and Positional Reading Arc positions.

  13. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    PubMed

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  14. A Vision-Based Self-Calibration Method for Robotic Visual Inspection Systems

    PubMed Central

    Yin, Shibin; Ren, Yongjie; Zhu, Jigui; Yang, Shourui; Ye, Shenghua

    2013-01-01

    A vision-based robot self-calibration method is proposed in this paper to evaluate the kinematic parameter errors of a robot using a visual sensor mounted on its end-effector. This approach could be performed in the industrial field without external, expensive apparatus or an elaborate setup. A robot Tool Center Point (TCP) is defined in the structural model of a line-structured laser sensor, and aligned to a reference point fixed in the robot workspace. A mathematical model is established to formulate the misalignment errors with kinematic parameter errors and TCP position errors. Based on the fixed point constraints, the kinematic parameter errors and TCP position errors are identified with an iterative algorithm. Compared to the conventional methods, this proposed method eliminates the need for a robot-based-frame and hand-to-eye calibrations, shortens the error propagation chain, and makes the calibration process more accurate and convenient. A validation experiment is performed on an ABB IRB2400 robot. An optimal configuration on the number and distribution of fixed points in the robot workspace is obtained based on the experimental results. Comparative experiments reveal that there is a significant improvement of the measuring accuracy of the robotic visual inspection system. PMID:24300597

  15. Optimized universal color palette design for error diffusion

    NASA Astrophysics Data System (ADS)

    Kolpatzik, Bernd W.; Bouman, Charles A.

    1995-04-01

    Currently, many low-cost computers can only simultaneously display a palette of 256 color. However, this palette is usually selectable from a very large gamut of available colors. For many applications, this limited palette size imposes a significant constraint on the achievable image quality. We propose a method for designing an optimized universal color palette for use with halftoning methods such as error diffusion. The advantage of a universal color palette is that it is fixed and therefore allows multiple images to be displayed simultaneously. To design the palette, we employ a new vector quantization method known as sequential scalar quantization (SSQ) to allocate the colors in a visually uniform color space. The SSQ method achieves near-optimal allocation, but may be efficiently implemented using a series of lookup tables. When used with error diffusion, SSQ adds little computational overhead and may be used to minimize the visual error in an opponent color coordinate system. We compare the performance of the optimized algorithm to standard error diffusion by evaluating a visually weighted mean-squared-error measure. Our metric is based on the color difference in CIE L*AL*B*, but also accounts for the lowpass characteristic of human contrast sensitivity.

  16. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  17. Smartphone Assessment of Knee Flexion Compared to Radiographic Standards

    PubMed Central

    Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.

    2017-01-01

    Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062

  18. Assessing FAÇADE Visibility in 3d City Models for City Marketing

    NASA Astrophysics Data System (ADS)

    Albrecht, F.; Moser, J.; Hijazi, I.

    2013-08-01

    In city marketing, different applications require the evaluation of the visual impression of displays in the urban environment on people that visit the city. Therefore, this research focuses on the way how visual displays on façades for movie performances are perceived during a cultural event triggered by city marketing. We describe the different visibility analysis methods that are applicable to the analysis of façades. The methods advanced from the domains of Geographic Information Science, architecture and computer graphics. A detailed scenario is described in order to perform a requirements analysis for identifying the requirements to visibility information. This visibility information needs to describe the visual perception of displays on façades adequately. The requirements are compared to the visibility information that can be provided by the visibility methods. A discussion of the comparison summarizes the advantages and disadvantages of existing visibility analysis methods for describing the visibility of façades. The results show that part of the researched approaches is able to support the requirements to visibility information. But they also show that for a complete support of the entire analysis workflow, there remain unsolved workflow integration issues.

  19. An evaluation of root resorption after orthodontic treatment.

    PubMed

    Thomas, E; Evans, W G; Becker, P

    2012-08-01

    Root resorption is commonly seen, albeit in varying degrees, in cases that have been treated orthodontically. In this retrospective study the objective was to compare the amount of root resorption observed after active orthodontic treatment had been completed with one of three different appliance systems, namely, Tip Edge, Modified Edgewise and Damon. The sample consisted of pre and post-treatment cephalograms of sixty eight orthodontic cases. Root resorption of the maxillary central incisor was assessed from pre- and post- treatment lateral ce phalograms using two methods. In the first, overall tooth length from the incisal edge to the apex was measured on both pre and post-treatment lateral cephalograms and root resorption was recorded as an actual millimetre loss of tooth length. There was a significant upward linear trend (p = 0.052) for root resorption from the Tip Edge Group to the Damon Group. In the second method root resorption was visually evaluated by using the five grade ordinal scale of Levander and Malmgren (1988). It was found that the majorty of cases in the sample came under Grade 1 and Grade 2 category of root resorption. Statistical evaluation tested the extent of agree ment in this study between visual measurements and actual measurements and demonstrated a significant association (p = 0.018) between the methods.

  20. Grape colour phenotyping: development of a method based on the reflectance spectrum.

    PubMed

    Rustioni, Laura; Basilico, Roberto; Fiori, Simone; Leoni, Alessandra; Maghradze, David; Failla, Osvaldo

    2013-01-01

    The colour of fruit is an important quality factor for cultivar classification and phenotyping techniques. Besides the subjective visual evaluation, new instruments and techniques can be used. This work aims at developping an objective, fast, easy and non-destructive method as a useful support for evaluating grapes' colour under different cultural and environmental conditions, as well as for breeding process and germplasm evaluation, supporting the plant characterization and the biodiversity preservation. Colours of 120 grape varieties were studied using reflectance spectra. The classification was realized using cluster and discriminant analysis. Reflectance of the whole berries surface was also compared with absorption properties of single skin extracts. A phenotyping method based on the reflectance spectra was developed, producing reliable colour classifications. A cultivar-independent index for pigment content evaluation has also been obtained. This work allowed the classification of the berry colour using an objective method. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Graphical Technique to Support the Teaching/Learning Process of Software Process Reference Models

    NASA Astrophysics Data System (ADS)

    Espinosa-Curiel, Ismael Edrein; Rodríguez-Jacobo, Josefina; Fernández-Zepeda, José Alberto

    In this paper, we propose a set of diagrams to visualize software process reference models (PRM). The diagrams, called dimods, are the combination of some visual and process modeling techniques such as rich pictures, mind maps, IDEF and RAD diagrams. We show the use of this technique by designing a set of dimods for the Mexican Software Industry Process Model (MoProSoft). Additionally, we perform an evaluation of the usefulness of dimods. The result of the evaluation shows that dimods may be a support tool that facilitates the understanding, memorization, and learning of software PRMs in both, software development organizations and universities. The results also show that dimods may have advantages over the traditional description methods for these types of models.

  2. How can we improve crop genotypes to increase stress resilience and productivity in a future climate? A new crop screening method based on productivity and resistance to abiotic stress

    PubMed Central

    Thiry, Arnauld A.; Chavez Dulanto, Perla N.; Reynolds, Matthew P.; Davies, William J.

    2016-01-01

    The need to accelerate the selection of crop genotypes that are both resistant to and productive under abiotic stress is enhanced by global warming and the increase in demand for food by a growing world population. In this paper, we propose a new method for evaluation of wheat genotypes in terms of their resilience to stress and their production capacity. The method quantifies the components of a new index related to yield under abiotic stress based on previously developed stress indices, namely the stress susceptibility index, the stress tolerance index, the mean production index, the geometric mean production index, and the tolerance index, which were created originally to evaluate drought adaptation. The method, based on a scoring scale, offers simple and easy visualization and identification of resilient, productive and/or contrasting genotypes according to grain yield. This new selection method could help breeders and researchers by defining clear and strong criteria to identify genotypes with high resilience and high productivity and provide a clear visualization of contrasts in terms of grain yield production under stress. It is also expected that this methodology will reduce the time required for first selection and the number of first-selected genotypes for further evaluation by breeders and provide a basis for appropriate comparisons of genotypes that would help reveal the biology behind high stress productivity of crops. PMID:27677299

  3. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    NASA Astrophysics Data System (ADS)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  4. Spatial and Global Sensory Suppression Mapping Encompassing the Central 10° Field in Anisometropic Amblyopia.

    PubMed

    Li, Jingjing; Li, Jinrong; Chen, Zidong; Liu, Jing; Yuan, Junpeng; Cai, Xiaoxiao; Deng, Daming; Yu, Minbin

    2017-01-01

    We investigate the efficacy of a novel dichoptic mapping paradigm in evaluating visual function of anisometropic amblyopes. Using standard clinical measures of visual function (visual acuity, stereo acuity, Bagolini lenses, and neutral density filters) and a novel quantitative mapping technique, 26 patients with anisometropic amblyopia (mean age = 19.15 ± 4.42 years) were assessed. Two additional psychophysical interocular suppression measurements were tested with dichoptic global motion coherence and binocular phase combination tasks. Luminance reduction was achieved by placing neutral density filters in front of the normal eye. Our study revealed that suppression changes across the central 10° visual field by mean luminance modulation in amblyopes as well as normal controls. Using simulation and an elimination of interocular suppression, we identified a novel method to effectively reflect the distribution of suppression in anisometropic amblyopia. Additionally, the new quantitative mapping technique was in good agreement with conventional clinical measures, such as interocular acuity difference (P < 0.001) and stereo acuity (P = 0.005). There was a good consistency between the results of interocular suppression with dichoptic mapping paradigm and the results of the other two psychophysical methods (suppression mapping versus binocular phase combination, P < 0.001; suppression mapping versus global motion coherence, P = 0.005). The dichoptic suppression mapping technique is an effective method to represent impaired visual function in patients with anisometropic amblyopia. It offers a potential in "micro-"antisuppression mapping tests and therapies for amblyopia.

  5. A novel stimulation method for multi-class SSVEP-BCI using intermodulation frequencies

    NASA Astrophysics Data System (ADS)

    Chen, Xiaogang; Wang, Yijun; Zhang, Shangen; Gao, Shangkai; Hu, Yong; Gao, Xiaorong

    2017-04-01

    Objective. Steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) has been widely investigated because of its easy system configuration, high information transfer rate (ITR) and little user training. However, due to the limitations of brain responses and the refresh rate of a monitor, the available stimulation frequencies for practical BCI application are generally restricted. Approach. This study introduced a novel stimulation method using intermodulation frequencies for SSVEP-BCIs that had targets flickering at the same frequency but with different additional modulation frequencies. The additional modulation frequencies were generated on the basis of choosing desired flickering frequencies. The conventional frame-based ‘on/off’ stimulation method was used to realize the desired flickering frequencies. All visual stimulation was present on a conventional LCD screen. A 9-target SSVEP-BCI based on intermodulation frequencies was implemented for performance evaluation. To optimize the stimulation design, three approaches (C: chromatic; L: luminance; CL: chromatic and luminance) were evaluated by online testing and offline analysis. Main results. SSVEP-BCIs with different paradigms (C, L, and CL) enabled us not only to encode more targets, but also to reliably evoke intermodulation frequencies. The online accuracies for the three paradigms were 91.67% (C), 93.98% (L), and 96.41% (CL). The CL condition achieved the highest classification performance. Significance. These results demonstrated the efficacy of three approaches (C, L, and CL) for eliciting intermodulation frequencies for multi-class SSVEP-BCIs. The combination of chromatic and luminance characteristics of the visual stimuli is the most efficient way for the intermodulation frequency coding method.

  6. Annotation Graphs: A Graph-Based Visualization for Meta-Analysis of Data Based on User-Authored Annotations.

    PubMed

    Zhao, Jian; Glueck, Michael; Breslav, Simon; Chevalier, Fanny; Khan, Azam

    2017-01-01

    User-authored annotations of data can support analysts in the activity of hypothesis generation and sensemaking, where it is not only critical to document key observations, but also to communicate insights between analysts. We present annotation graphs, a dynamic graph visualization that enables meta-analysis of data based on user-authored annotations. The annotation graph topology encodes annotation semantics, which describe the content of and relations between data selections, comments, and tags. We present a mixed-initiative approach to graph layout that integrates an analyst's manual manipulations with an automatic method based on similarity inferred from the annotation semantics. Various visual graph layout styles reveal different perspectives on the annotation semantics. Annotation graphs are implemented within C8, a system that supports authoring annotations during exploratory analysis of a dataset. We apply principles of Exploratory Sequential Data Analysis (ESDA) in designing C8, and further link these to an existing task typology in the visualization literature. We develop and evaluate the system through an iterative user-centered design process with three experts, situated in the domain of analyzing HCI experiment data. The results suggest that annotation graphs are effective as a method of visually extending user-authored annotations to data meta-analysis for discovery and organization of ideas.

  7. Meningioma Causing Visual Impairment: Outcomes and Toxicity After Intensity Modulated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maclean, Jillian, E-mail: jillian.maclean@uclh.nhs.uk; Fersht, Naomi; Bremner, Fion

    2013-03-15

    Purpose: To evaluate ophthalmologic outcomes and toxicity of intensity modulated radiation therapy (IMRT) in patients with meningiomas causing visual deficits. Methods and Materials: A prospective observational study with formal ophthalmologic and clinical assessment of 30 consecutive cases of meningioma affecting vision treated with IMRT from 2007 to 2011. Prescriptions were 50.4 Gy to mean target dose in 28 daily fractions. The median follow-up time was 28 months. Twenty-six meningiomas affected the anterior visual pathway (including 3 optic nerve sheath meningiomas); 4 were posterior to the chiasm. Results: Vision improved objectively in 12 patients (40%). Improvements were in visual field (5/16more » patients), color vision (4/9 patients), acuity (1/15 patients), extraocular movements (3/11 patients), ptosis (1/5 patients), and proptosis (2/6 patients). No predictors of clinical response were found. Two patients had minor reductions in tumor dimensions on magnetic resonance imaging, 1 patient had radiological progression, and the other patients were stable. One patient experienced grade 2 keratitis, 1 patient had a minor visual field loss, and 5 patients had grade 1 dry eye. Conclusion: IMRT is an effective method for treating meningiomas causing ophthalmologic deficits, and toxicity is minimal. Thorough ophthalmologic assessment is important because clinical responses often occur in the absence of radiological change.« less

  8. Ocular haemodynamic changes after single treatment with photodynamic therapy assessed with non-invasive techniques.

    PubMed

    Maar, Noemi; Pemp, Berthold; Kircher, Karl; Luksch, Alexandra; Weigert, Günther; Polska, Elzbieta; Tittl, Michael; Stur, Michael; Schmetterer, Leopold

    2009-09-01

    To investigate in patients with neovascular age-related macular degeneration (ARMD) the changes in ocular perfusion caused by single treatment with photodynamic therapy (PDT) by different non-invasive methods; to evaluate correlations between relative changes of ocular haemodynamic parameters after PDT among each other and compared to morphological parameters; and to assess this in relation to early changes of visual acuity. 17 consecutive patients with subfoveal choroidal neovascularization (CNV) caused by ARMD scheduled for PDT without previous PDT treatment (four patients with predominantly classic CNV and 13 patients with occult CNV). best-corrected visual acuity (before PDT, 6 and 8 weeks after PDT), fundus photography, fluorescein angiography, haemodynamic measurements with laser Doppler flowmetry (LDF), laser interferometry and ocular blood flow (OBF) tonometry (baseline and 1, 2, 6 and 8 weeks after treatment). choroidal blood flow (CHBF), fundus pulsation amplitude (FPA), pulsatile ocular blood flow (POBF), visual acuity. Changes smaller than 20% were considered clinically irrelevant. Ocular haemodynamic parameters did not change significantly in the follow-up period. Changes of haemodynamic parameters showed no correlation to treatment spot, morphological changes or visual acuity. Changes of visual acuity were comparable to results of earlier studies. Single treatment with PDT did not modify ocular blood flow parameters above 20% as assessed with different non-invasive methods.

  9. Reliable Analysis of Single-Unit Recordings from the Human Brain under Noisy Conditions: Tracking Neurons over Hours

    PubMed Central

    Boström, Jan; Elger, Christian E.; Mormann, Florian

    2016-01-01

    Recording extracellulary from neurons in the brains of animals in vivo is among the most established experimental techniques in neuroscience, and has recently become feasible in humans. Many interesting scientific questions can be addressed only when extracellular recordings last several hours, and when individual neurons are tracked throughout the entire recording. Such questions regard, for example, neuronal mechanisms of learning and memory consolidation, and the generation of epileptic seizures. Several difficulties have so far limited the use of extracellular multi-hour recordings in neuroscience: Datasets become huge, and data are necessarily noisy in clinical recording environments. No methods for spike sorting of such recordings have been available. Spike sorting refers to the process of identifying the contributions of several neurons to the signal recorded in one electrode. To overcome these difficulties, we developed Combinato: a complete data-analysis framework for spike sorting in noisy recordings lasting twelve hours or more. Our framework includes software for artifact rejection, automatic spike sorting, manual optimization, and efficient visualization of results. Our completely automatic framework excels at two tasks: It outperforms existing methods when tested on simulated and real data, and it enables researchers to analyze multi-hour recordings. We evaluated our methods on both short and multi-hour simulated datasets. To evaluate the performance of our methods in an actual neuroscientific experiment, we used data from from neurosurgical patients, recorded in order to identify visually responsive neurons in the medial temporal lobe. These neurons responded to the semantic content, rather than to visual features, of a given stimulus. To test our methods with multi-hour recordings, we made use of neurons in the human medial temporal lobe that respond selectively to the same stimulus in the evening and next morning. PMID:27930664

  10. Detection of Ballast Damage by In-Situ Vibration Measurement of Sleepers

    NASA Astrophysics Data System (ADS)

    Lam, H. F.; Wong, M. T.; Keefe, R. M.

    2010-05-01

    Ballasted track is one of the most important elements of railway transportation systems worldwide. Owing to its importance in railway safety, many monitoring and evaluation methods have been developed. Current railway track monitoring systems are comprehensive, fast and efficient in testing railway track level and alignment, rail gauge, rail corrugation, etc. However, the monitoring of ballast condition still relies very much on visual inspection and core tests. Although extensive research has been carried out in the development of non-destructive methods for ballast condition evaluation, a commonly accepted and cost-effective method is still in demand. In Hong Kong practice, if abnormal train vibration is reported by the train operator or passengers, permanent way inspectors will locate the problem area by track geometry measurement. It must be pointed out that visual inspection can only identify ballast damage on the track surface, the track geometry deficiencies and rail twists can be detected using a track gauge. Ballast damage under the sleeper loading area and the ballast shoulder, which are the main factors affecting track stability and ride quality, are extremely difficult if not impossible to be detected by visual inspection. Core test is a destructive test, which is expensive, time consuming and may be disruptive to traffic. A fast real-time ballast damage detection method that can be implemented by permanent way inspectors with simple equipment can certainly provide valuable information for engineers in assessing the safety and riding quality of ballasted track systems. The main objective of this paper is to study the feasibility in using the vibration characteristics of sleepers in quantifying the ballast condition under the sleepers, and so as to explore the possibility in developing a handy method for the detection of ballast damage based on the measured vibration of sleepers.

  11. Using single-case experimental design methodology to evaluate the effects of the ABC method for nursing staff on verbal aggressive behaviour after acquired brain injury.

    PubMed

    Winkens, Ieke; Ponds, Rudolf; Pouwels, Climmy; Eilander, Henk; van Heugten, Caroline

    2014-01-01

    The ABC method is a basic and simplified form of behavioural modification therapy for use by nurses. ABC refers to the identification of Antecedent events, target Behaviours, and Consequent events. A single-case experimental AB design was used to evaluate the effects of the ABC method on a woman diagnosed with olivo-ponto-cerebellar ataxia. Target behaviour was verbal aggressive behaviour during ADL care, assessed at 9 time points immediately before implementation of the ABC method and at 36 time points after implementation. A randomisation test showed a significant treatment effect between the baseline and intervention phases (t = .58, p = .03; ES [Nonoverlap All Pairs] = .62). Visual analysis, however, showed that the target behaviour was still present after implementation of the method and that on some days the nurses even judged the behaviour to be more severe than at baseline. Although the target behaviour was still present after treatment, the ABC method seems to be a promising tool for decreasing problem behaviour in patients with acquired brain injury. It is worth investigating the effects of this method in future studies. When interpreting single-subject data, both visual inspection and statistical analysis are needed to determine whether treatment is effective and whether the effects lead to clinically desirable results.

  12. Designing Visual Aids That Promote Risk Literacy: A Systematic Review of Health Research and Evidence-Based Design Heuristics.

    PubMed

    Garcia-Retamero, Rocio; Cokely, Edward T

    2017-06-01

    Background Effective risk communication is essential for informed decision making. Unfortunately, many people struggle to understand typical risk communications because they lack essential decision-making skills. Objective The aim of this study was to review the literature on the effect of numeracy on risk literacy, decision making, and health outcomes, and to evaluate the benefits of visual aids in risk communication. Method We present a conceptual framework describing the influence of numeracy on risk literacy, decision making, and health outcomes, followed by a systematic review of the benefits of visual aids in risk communication for people with different levels of numeracy and graph literacy. The systematic review covers scientific research published between January 1995 and April 2016, drawn from the following databases: Web of Science, PubMed, PsycINFO, ERIC, Medline, and Google Scholar. Inclusion criteria were investigation of the effect of numeracy and/or graph literacy, and investigation of the effect of visual aids or comparison of their effect with that of numerical information. Thirty-six publications met the criteria, providing data on 27,885 diverse participants from 60 countries. Results Transparent visual aids robustly improved risk understanding in diverse individuals by encouraging thorough deliberation, enhancing cognitive self-assessment, and reducing conceptual biases in memory. Improvements in risk understanding consistently produced beneficial changes in attitudes, behavioral intentions, trust, and healthy behaviors. Visual aids were found to be particularly beneficial for vulnerable and less skilled individuals. Conclusion Well-designed visual aids tend to be highly effective tools for improving informed decision making among diverse decision makers. We identify five categories of practical, evidence-based guidelines for heuristic evaluation and design of effective visual aids.

  13. [The application of X-ray imaging in forensic medicine].

    PubMed

    Kučerová, Stěpánka; Safr, Miroslav; Ublová, Michaela; Urbanová, Petra; Hejna, Petr

    2014-07-01

    X-ray is the most common, basic and essential imaging method used in forensic medicine. It serves to display and localize the foreign objects in the body and helps to detect various traumatic and pathological changes. X-ray imaging is valuable in anthropological assessment of an individual. X-ray allows non-invasive evaluation of important findings before the autopsy and thus selection of the optimal strategy for dissection. Basic indications for postmortem X-ray imaging in forensic medicine include gunshot and explosive fatalities (identification and localization of projectiles or other components of ammunition, visualization of secondary missiles), sharp force injuries (air embolism, identification of the weapon) and motor vehicle related deaths. The method is also helpful for complex injury evaluation in abused victims or in persons where abuse is suspected. Finally, X-ray imaging still remains the gold standard method for identification of unknown deceased. With time modern imaging methods, especially computed tomography and magnetic resonance imaging, are more and more applied in forensic medicine. Their application extends possibilities of the visualization the bony structures toward a more detailed imaging of soft tissues and internal organs. The application of modern imaging methods in postmortem body investigation is known as digital or virtual autopsy. At present digital postmortem imaging is considered as a bloodless alternative to the conventional autopsy.

  14. Asymmetries and Visual Field Summaries as Predictors of Glaucoma in the Ocular Hypertension Treatment Study

    PubMed Central

    Levine, Richard A.; Demirel, Shaban; Fan, Juanjuan; Keltner, John L.; Johnson, Chris A.; Kass, Michael A.

    2007-01-01

    Purpose To evaluate whether baseline visual field data and asymmetries between eyes predict the onset of primary open-angle glaucoma (POAG) in Ocular Hypertension Treatment Study (OHTS) participants. Methods A new index, mean prognosis (MP), was designed for optimal combination of visual field thresholds, to discriminate between eyes that developed POAG from eyes that did not. Baseline intraocular pressure (IOP) in fellow eyes was used to construct measures of IOP asymmetry. Age-adjusted baseline thresholds were used to develop indicators of visual field asymmetry and summary measures of visual field defects. Marginal multivariate failure time models were constructed that relate the new index MP, IOP asymmetry, and visual field asymmetry to POAG onset for OHTS participants. Results The marginal multivariate failure time analysis showed that the MP index is significantly related to POAG onset (P < 0.0001) and appears to be a more highly significant predictor of POAG onset than either mean deviation (MD; P = 0.17) or pattern standard deviation (PSD; P = 0.046). A 1-mm Hg increase in IOP asymmetry between fellow eyes is associated with a 17% increase in risk for development of POAG. When threshold asymmetry between eyes existed, the eye with lower thresholds was at a 37% greater risk of development of POAG, and this feature was more predictive of POAG onset than the visual field index MD, though not as strong a predictor as PSD. Conclusions The MP index, IOP asymmetry, and binocular test point asymmetry can assist in clinical evaluation of eyes at risk of development of POAG. PMID:16936102

  15. Visual assessment of brain magnetic resonance imaging detects injury to cognitive regulatory sites in patients with heart failure.

    PubMed

    Pan, Alan; Kumar, Rajesh; Macey, Paul M; Fonarow, Gregg C; Harper, Ronald M; Woo, Mary A

    2013-02-01

    Heart failure (HF) patients exhibit depression and executive function impairments that contribute to HF mortality. Using specialized magnetic resonance imaging (MRI) analysis procedures, brain changes appear in areas regulating these functions (mammillary bodies, hippocampi, and frontal cortex). However, specialized MRI procedures are not part of standard clinical assessment for HF (which is usually a visual evaluation), and it is unclear whether visual MRI examination can detect changes in these structures. Using brain MRI, we visually examined the mammillary bodies and frontal cortex for global and hippocampi for global and regional tissue changes in 17 HF and 50 control subjects. Significantly global changes emerged in the right mammillary body (HF 1.18 ± 1.13 vs control 0.52 ± 0.74; P = .024), right hippocampus (HF 1.53 ± 0.94 vs control 0.80 ± 0.86; P = .005), and left frontal cortex (HF 1.76 ± 1.03 vs control 1.24 ± 0.77; P = .034). Comparison of the visual method with specialized MRI techniques corroborates right hippocampal and left frontal cortical, but not mammillary body, tissue changes. Visual examination of brain MRI can detect damage in HF in areas regulating depression and executive function, including the right hippocampus and left frontal cortex. Visual MRI assessment in HF may facilitate evaluation of injury to these structures and the assessment of the impact of potential treatments for this damage. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. New Therapeutic Approaches in Diabetic Retinopathy

    PubMed Central

    Vaziri, Kamyar; Schwartz, Stephen G.; Relhan, Nidhi; Kishor, Krishna S.; Flynn Jr, Harry W.

    2015-01-01

    Diabetic retinopathy is a common microvascular complication of diabetes mellitus. It affects a substantial proportion of US adults over age 40. The condition is a leading cause of visual loss. Much attention has been given to expanding the role of current treatments along with investigating various novel therapies and drug delivery methods. In the treatment of diabetic macular edema (DME), intravitreal pharmacotherapies, especially anti-vascular endothelial growth factor (anti-VEGF) agents, have gained popularity. Currently, anti-VEGF agents are often used as first-line agents in center-involved DME, with recent data suggesting that among these agents, aflibercept leads to better visual outcomes in patients with worse baseline visual acuities. While photocoagulation remains the standard treatment for proliferative diabetic retinopathy (PDR), recent FDA approvals of ranibizumab and aflibercept in the management of diabetic retinopathy associated with DME may suggest a potential for pharmacologic treatments of PDR as well. Novel therapies, including small interfering RNAs, chemokines, kallikrein-kinin inhibitors, and various anti-angiogenic agents, are currently being evaluated for the management of diabetic retinopathy and DME. In addition to these strategies, novel drug delivery methods such as sustained-release implants and refillable reservoir implants are either under active evaluation or have recently gained FDA approval. This review provides an update on the novel developments in the treatment of diabetic retinopathy. PMID:26676668

  17. Plasticity of the human visual system after retinal gene therapy in patients with Leber's congenital amaurosis.

    PubMed

    Ashtari, Manzar; Zhang, Hui; Cook, Philip A; Cyckowski, Laura L; Shindler, Kenneth S; Marshall, Kathleen A; Aravand, Puya; Vossough, Arastoo; Gee, James C; Maguire, Albert M; Baker, Chris I; Bennett, Jean

    2015-07-15

    Much of our knowledge of the mechanisms underlying plasticity in the visual cortex in response to visual impairment, vision restoration, and environmental interactions comes from animal studies. We evaluated human brain plasticity in a group of patients with Leber's congenital amaurosis (LCA), who regained vision through gene therapy. Using non-invasive multimodal neuroimaging methods, we demonstrated that reversing blindness with gene therapy promoted long-term structural plasticity in the visual pathways emanating from the treated retina of LCA patients. The data revealed improvements and normalization along the visual fibers corresponding to the site of retinal injection of the gene therapy vector carrying the therapeutic gene in the treated eye compared to the visual pathway for the untreated eye of LCA patients. After gene therapy, the primary visual pathways (for example, geniculostriate fibers) in the treated retina were similar to those of sighted control subjects, whereas the primary visual pathways of the untreated retina continued to deteriorate. Our results suggest that visual experience, enhanced by gene therapy, may be responsible for the reorganization and maturation of synaptic connectivity in the visual pathways of the treated eye in LCA patients. The interactions between the eye and the brain enabled improved and sustained long-term visual function in patients with LCA after gene therapy. Copyright © 2015, American Association for the Advancement of Science.

  18. Visualization of Middle Ear Ossicles in Elder Subjects with Ultra-short Echo Time MR Imaging.

    PubMed

    Naganawa, Shinji; Nakane, Toshiki; Kawai, Hisashi; Taoka, Toshiaki; Suzuki, Kojiro; Iwano, Shingo; Satake, Hiroko; Grodzki, David

    2017-04-10

    To evaluate the visualization of middle ear ossicles by ultra-short echo time magnetic resonance (MR) imaging at 3T in subjects over 50 years old. Sixty ears from 30 elder patients that underwent surgical or interventional treatment for neurovascular diseases were included (ages: 50-82, median age: 65; 10 men, 20 women). Patients received follow-up MR imaging including routine T 1 - and T 2 -weighted images, time-of-flight MR angiography, and ultra-short echo time imaging (PETRA, pointwise encoding time reduction with radial acquisition). All patients underwent computed tomography (CT) angiography before treatment. Thin-section source CT images were correlated with PETRA images. Scan parameters for PETRA were: TR 3.13, TE 0.07, flip angle 6 degrees, 0.83 × 0.83 × 0.83 mm resolution, 3 min 43 s scan time. Two radiologists retrospectively evaluated the visibility of each ossicular structure as positive or negative using PETRA images. The structures evaluated included the head of the malleus, manubrium of the malleus, body of the incus, long process of the incus, and the stapes. Signal intensity of the ossicles was classified as: between labyrinthine fluid and air, similar to labyrinthine fluid, between labyrinthine fluid and cerebellar parenchyma, or higher than cerebellar parenchyma. In all ears, the body of the incus was visible. The head of the malleus was visualized in 36/60 ears. The manubrium of the malleus and long process of the incus was visualized in 1/60 and 4/60 ears, respectively. The stapes were not visualized in any ear. Signal intensity of the visible structures was between labyrinthine fluid and air in all ears. The body of the incus was consistently visualized with intensity between air and labyrinthine fluid on PETRA images in aged subjects. Poor visualization of the manubrium of the malleus, long process of the incus, and the stapes limits clinical significance of middle ear imaging with current PETRA methods.

  19. Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian Tobias Alwin; Choi, Chul Young; Müller, Matthias; Gerl, Matthias; Gerl, Ralf Helmar

    2016-01-01

    Purpose To evaluate visual outcomes following implantation of a trifocal diffractive intraocular lens (IOL) and to analyze their correlation with patient satisfaction and ease of performing daily tasks. Methods This was a prospective study enrolling 100 eyes of 50 patients undergoing cataract surgery with implantation of trifocal IOL AT LISA tri 839MP. Visual and refractive outcomes were evaluated during a 3-month follow-up. Postoperatively, a questionnaire was used to evaluate patient satisfaction with regard to surgical outcome, spectacle independence, perception of photic phenomena, and ease of performing some vision-related activities. Results A total of 91%, 87%, and 79% of eyes achieved a monocular uncorrected distance, near, and intermediate visual acuity of 0.1 logarithm of the minimum angle of resolution or better, respectively. After the surgery, 96% of the patients could perform their daily activities without problems. The mean spectacle independence scores for reading, doing computer work, and for distance were 10.33 ± 12.47, 5.71 ± 11.90, and 3.92 ± 9.77, respectively (scale: 0 = no spectacles needed; 40 = spectacles always needed). No correlation was found between spectacle independence and visual outcome (-0.101 ≤ r ≤ 0.244, p ≥ 0.087). Mean scores (0 = no symptoms; 40 = strong symptoms) for glare at night, ghost images, and halos were 15.15 ± 12.02, 4.49 ± 7.92, and 13.34 ± 10.82, respectively. No correlation was found between photic phenomena and visual outcome (-0.199 ≤ r ≤ 0.209, p ≥ 0.150). A total of 80% of patients reported satisfaction with the surgery outcome, and 86% would recommend the surgery to friends and family. Conclusions Implantation of the AT LISA tri 839MP IOL after cataract surgery provides effective visual restoration associated with a minimal level of photic phenomena, a positive impact on the performance of vision-related daily activities, and a high level of postoperative patient satisfaction. PMID:27247517

  20. Comparison of the Handy Eye Chart and the Lea Symbols Chart in a population of deaf children aged 7–18 years

    PubMed Central

    Gorham, John Paul; Bruce, Beau B.; Hutchinson, Amy K.

    2016-01-01

    Purpose To compare the results of visual acuity testing in a population of deaf children using the Handy Eye Chart versus the Lea Symbols Chart and to compare testability and preference between charts. Methods A total of 24 participants were recruited at the Atlanta Area School for the Deaf. Visual Acuity was evaluated using the Handy Eye Chart and the Lea Symbols Chart. Patient preference and duration of testing were measured. Results The mean difference between the visual acuity as measured by each chart was –0.02 logMAR (95% CI, −0.06 to 0.03). Testing with the Handy Eye Chart was an average of 13.79 seconds faster than testing with the Lea Symbols Chart (95% CI, 1.1–26.47; P = 0.03). Of the 24 participants, 17 (71%) preferred the Handy Eye Chart (95% CI: 49%–87%; P = 0.07). Conclusions The Handy Eye Chart is a fast, valid, and preferred tool for measuring visual acuity in deaf children age 7–18 years. Additional research is needed to evaluate the utility of the Handy Eye Chart in younger children and deaf adults. PMID:27164427

  1. Visual impairment, visual functioning, and quality of life assessments in patients with glaucoma.

    PubMed Central

    Parrish, R K

    1996-01-01

    BACKGROUND/PURPOSE: To determine the relation between visual impairment, visual functioning, and the global quality of life in patients with glaucoma. METHODS: Visual impairment, defined with the American Medical Association Guides to the Evaluation of Permanent Impairment; visual functioning, measured with the VF-14 and the Field Test Version of the National Eye Institute-Visual Functioning Questionnaire (NEI-VFQ); and the global quality of life, assessed with the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), were determined in 147 consecutive patients with glaucoma. RESULTS: None of the SF-36 domains demonstrated more than a weak correlation with visual impairment. The VF-14 scores were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual field impairment; vision specific social functioning, near activities, vision specific role difficulties, general vision, vision specific mental health, color vision, and driving were modestly correlated; visual pain was weakly correlated; and two were not significantly correlated. Correcting for visual actuity weakened the strength of the correlation coefficients. CONCLUSIONS: The SF-36 is unlikely to be useful in determining visual impairment in patients with glaucoma. Based on the moderate correlation between visual field impairment and the VF-14 score, this questionnaire may be generalizable to patients with glaucoma. Several of the NEI-VFQ scales correlate with visual field impairment scores in patients with a wide range of glaucomatous damage. PMID:8981717

  2. Spatial distribution visualization of PWM continuous variable-rate spray

    USDA-ARS?s Scientific Manuscript database

    Chemical application is a dynamic spatial distribution process, during which spray liquid covers the targets with certain thickness and uniformity. Therefore, it is important to study the 2-D and 3-D (dimensional) spray distribution to evaluate spraying quality. The curve-surface generation methods ...

  3. Clinical evaluation of near-infrared light transillumination in approximal dentin caries detection.

    PubMed

    Ozkan, Gokhan; Guzel, Kadriye Gorkem Ulu

    2017-08-01

    The objective of this clinical study was to compare conventional caries detection techniques, pen-type laser fluorescence device, and near-infrared light transillumination method in approximal dentin caries lesions. The study included 157 patients, aged 12-18, without any cavity in the posterior teeth. Two calibrated examiners carried out the assessments of selected approximal caries sites independently. After the assessments, the unopened sites were excluded and a total of 161 approximal sites were included in the study. When both the examiners arrived at a consensus regarding the presence of dentin caries, the detected lesions were opened with a conical diamond burr, the cavity extent was examined and validated (gold standard). Sensitivity, specificity, negative predictive value, positive predictive value, accuracy, and area under the ROC curve (Az) values among the caries detection methods were calculated. Bitewing radiography and near-infrared (NIR) light transillumination methods showed the highest sensitivity (0.83-0.82) and accuracy (0.82-0.80) among the methods. Visual inspection showed the lowest sensitivity (0.54). Laser fluorescence device and visual inspection showed nearly equal performance. Near-infrared light transillumination can be used as an alternative method to approximal dentin caries detection. Visual inspection and laser fluorescence device alone should not be used for approximal dentin caries.

  4. Evaluation of Postural Control in Glaucoma Patients Using a Virtual 1 Reality Environment

    PubMed Central

    Diniz-Filho, Alberto; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A.

    2015-01-01

    Purpose To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in glaucoma patients. Design Cross-sectional study. Participants The study involved 42 glaucoma patients with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Methods Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Main Outcome Measures Torque moments around the center of foot pressure on the force platform were measured and the standard deviations (STD) of these torque moments were calculated as a measurement of postural stability and reported in Newton meter (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Results Glaucoma patients had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) as well as rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared to those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with history of falls in glaucoma patients (incidence-rate ratio = 1.85; 95% CI: 1.30 – 2.63; P = 0.001). Conclusions The study presented and validated a novel paradigm for evaluation of balance control in glaucoma patients based on the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with history of falls and may help to provide a better understanding of balance control in glaucoma patients. PMID:25892017

  5. A Fuzzy Integral Ensemble Method in Visual P300 Brain-Computer Interface.

    PubMed

    Cavrini, Francesco; Bianchi, Luigi; Quitadamo, Lucia Rita; Saggio, Giovanni

    2016-01-01

    We evaluate the possibility of application of combination of classifiers using fuzzy measures and integrals to Brain-Computer Interface (BCI) based on electroencephalography. In particular, we present an ensemble method that can be applied to a variety of systems and evaluate it in the context of a visual P300-based BCI. Offline analysis of data relative to 5 subjects lets us argue that the proposed classification strategy is suitable for BCI. Indeed, the achieved performance is significantly greater than the average of the base classifiers and, broadly speaking, similar to that of the best one. Thus the proposed methodology allows realizing systems that can be used by different subjects without the need for a preliminary configuration phase in which the best classifier for each user has to be identified. Moreover, the ensemble is often capable of detecting uncertain situations and turning them from misclassifications into abstentions, thereby improving the level of safety in BCI for environmental or device control.

  6. On-Road Driving Performance by Persons with Hemianopia and Quadrantanopia

    PubMed Central

    Wood, Joanne M.; McGwin, Gerald; Elgin, Jennifer; Vaphiades, Michael S.; Braswell, Ronald A.; DeCarlo, Dawn K.; Kline, Lanning B.; Meek, G. Christine; Searcey, Karen; Owsley, Cynthia

    2009-01-01

    Purpose This study was designed to examine the on-road driving performance of drivers with hemianopia and quadrantanopia compared with age-matched controls. Methods Participants included persons with hemianopia or quadrantanopia and those with normal visual fields. Visual and cognitive function tests were administered, including confirmation of hemianopia and quadrantanopia through visual field testing. Driving performance was assessed using a dual-brake vehicle and monitored by a certified driving rehabilitation specialist. The route was 14.1 miles of city and interstate driving. Two “back-seat” evaluators masked to drivers’ clinical characteristics independently assessed driving performance using a standard scoring system. Results Participants were 22 persons with hemianopia and 8 with quadrantanopia (mean age, 53 ± 20 years) and 30 participants with normal fields (mean age, 52 ± 19 years). Inter-rater agreement for back-seat evaluators was 96%. All drivers with normal fields were rated as safe to drive, while 73% (16/22) of hemianopic and 88% (7/8) of quadrantanopic drivers received safe ratings. Drivers with hemianopia or quadrantanopia who displayed on-road performance problems tended to have difficulty with lane position, steering steadiness, and gap judgment compared to controls. Clinical characteristics associated with unsafe driving were slowed visual processing speed, reduced contrast sensitivity and visual field sensitivity. Conclusions Some drivers with hemianopia or quadrantanopia are fit to drive compared with age-matched control drivers. Results call into question the fairness of governmental policies that categorically deny licensure to persons with hemianopia or quadrantanopia without the opportunity for on-road evaluation. PMID:18936138

  7. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model

    PubMed Central

    Konstantinova, Jelizaveta; Xu, Guanghua; He, Bo; Aminzadeh, Vahid; Xie, Jun; Wurdemann, Helge; Althoefer, Kaspar

    2017-01-01

    Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information regarding tissue stiffness to surgeons. In this study, real-time visual stiffness feedback by sliding indentation palpation is proposed, validated, and compared with force feedback involving human subjects. In an experimental tele-manipulation environment, a dynamically updated color map depicting the stiffness of probed soft tissue is presented via a graphical interface. The force feedback is provided, aided by a master haptic device. The haptic device uses data acquired from an F/T sensor attached to the end-effector of a tele-manipulated robot. Hard nodule detection performance is evaluated for 2 modes (force feedback and visual stiffness feedback) of stiffness feedback on an artificial organ containing buried stiff nodules. From this artificial organ, a virtual-environment tissue model is generated based on sliding indentation measurements. Employing this virtual-environment tissue model, we compare the performance of human participants in distinguishing differently sized hard nodules by force feedback and visual stiffness feedback. Results indicate that the proposed distributed visual representation of tissue stiffness can be used effectively for hard nodule identification. The representation can also be used as a sufficient substitute for force feedback in tissue palpation. PMID:28248996

  8. Evaluation of stiffness feedback for hard nodule identification on a phantom silicone model.

    PubMed

    Li, Min; Konstantinova, Jelizaveta; Xu, Guanghua; He, Bo; Aminzadeh, Vahid; Xie, Jun; Wurdemann, Helge; Althoefer, Kaspar

    2017-01-01

    Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information regarding tissue stiffness to surgeons. In this study, real-time visual stiffness feedback by sliding indentation palpation is proposed, validated, and compared with force feedback involving human subjects. In an experimental tele-manipulation environment, a dynamically updated color map depicting the stiffness of probed soft tissue is presented via a graphical interface. The force feedback is provided, aided by a master haptic device. The haptic device uses data acquired from an F/T sensor attached to the end-effector of a tele-manipulated robot. Hard nodule detection performance is evaluated for 2 modes (force feedback and visual stiffness feedback) of stiffness feedback on an artificial organ containing buried stiff nodules. From this artificial organ, a virtual-environment tissue model is generated based on sliding indentation measurements. Employing this virtual-environment tissue model, we compare the performance of human participants in distinguishing differently sized hard nodules by force feedback and visual stiffness feedback. Results indicate that the proposed distributed visual representation of tissue stiffness can be used effectively for hard nodule identification. The representation can also be used as a sufficient substitute for force feedback in tissue palpation.

  9. Focal damage to macaque photoreceptors produces persistent visual loss

    PubMed Central

    Strazzeri, Jennifer M.; Hunter, Jennifer J.; Masella, Benjamin D.; Yin, Lu; Fischer, William S.; DiLoreto, David A.; Libby, Richard T.; Williams, David R.; Merigan, William H.

    2014-01-01

    Insertion of light-gated channels into inner retina neurons restores neural light responses, light evoked potentials, visual optomotor responses and visually-guided maze behavior in mice blinded by retinal degeneration. This method of vision restoration bypasses damaged outer retina, providing stimulation directly to retinal ganglion cells in inner retina. The approach is similar to that of electronic visual protheses, but may offer some advantages, such as avoidance of complex surgery and direct targeting of many thousands of neurons. However, the promise of this technique for restoring human vision remains uncertain because rodent animal models, in which it has been largely developed, are not ideal for evaluating visual perception. On the other hand, psychophysical vision studies in macaque can be used to evaluate different approaches to vision restoration in humans. Furthermore, it has not been possible to test vision restoration in macaques, the optimal model for human-like vision, because there has been no macaque model of outer retina degeneration. In this study, we describe development of a macaque model of photoreceptor degeneration that can in future studies be used to test restoration of perception by visual prostheses. Our results show that perceptual deficits caused by focal light damage are restricted to locations at which photoreceptors are damaged, that optical coherence tomography (OCT) can be used to track such lesions, and that adaptive optics retinal imaging, which we recently used for in vivo recording of ganglion cell function, can be used in future studies to examine these lesions. PMID:24316158

  10. Wide-Field Fundus Autofluorescence for Retinitis Pigmentosa and Cone/Cone-Rod Dystrophy.

    PubMed

    Oishi, Akio; Oishi, Maho; Ogino, Ken; Morooka, Satoshi; Yoshimura, Nagahisa

    2016-01-01

    Retinitis pigmentosa and cone/cone-rod dystrophy are inherited retinal diseases characterized by the progressive loss of rod and/or cone photoreceptors. To evaluate the status of rod/cone photoreceptors and visual function, visual acuity and visual field tests, electroretinogram, and optical coherence tomography are typically used. In addition to these examinations, fundus autofluorescence (FAF) has recently garnered attention. FAF visualizes the intrinsic fluorescent material in the retina, which is mainly lipofuscin contained within the retinal pigment epithelium. While conventional devices offer limited viewing angles in FAF, the recently developed Optos machine enables recording of wide-field FAF. With wide-field analysis, an association between abnormal FAF areas and visual function was demonstrated in retinitis pigmentosa and cone-rod dystrophy. In addition, the presence of "patchy" hypoautofluorescent areas was found to be correlated with symptom duration. Although physicians should be cautious when interpreting wide-field FAF results because the peripheral parts of the image are magnified significantly, this examination method provides previously unavailable information.

  11. Producing Curious Affects: Visual Methodology as an Affecting and Conflictual Wunderkammer

    ERIC Educational Resources Information Center

    Staunaes, Dorthe; Kofoed, Jette

    2015-01-01

    Digital video cameras, smartphones, internet and iPads are increasingly used as visual research methods with the purpose of creating an affective corpus of data. Such visual methods are often combined with interviews or observations. Not only are visual methods part of the used research methods, the visual products are used as requisites in…

  12. Task–Technology Fit of Video Telehealth for Nurses in an Outpatient Clinic Setting

    PubMed Central

    Finkelstein, Stanley M.

    2014-01-01

    Abstract Background: Incorporating telehealth into outpatient care delivery supports management of consumer health between clinic visits. Task–technology fit is a framework for understanding how technology helps and/or hinders a person during work processes. Evaluating the task–technology fit of video telehealth for personnel working in a pediatric outpatient clinic and providing care between clinic visits ensures the information provided matches the information needed to support work processes. Materials and Methods: The workflow of advanced practice registered nurse (APRN) care coordination provided via telephone and video telehealth was described and measured using a mixed-methods workflow analysis protocol that incorporated cognitive ethnography and time–motion study. Qualitative and quantitative results were merged and analyzed within the task–technology fit framework to determine the workflow fit of video telehealth for APRN care coordination. Results: Incorporating video telehealth into APRN care coordination workflow provided visual information unavailable during telephone interactions. Despite additional tasks and interactions needed to obtain the visual information, APRN workflow efficiency, as measured by time, was not significantly changed. Analyzed within the task–technology fit framework, the increased visual information afforded by video telehealth supported the assessment and diagnostic information needs of the APRN. Conclusions: Telehealth must provide the right information to the right clinician at the right time. Evaluating task–technology fit using a mixed-methods protocol ensured rigorous analysis of fit within work processes and identified workflows that benefit most from the technology. PMID:24841219

  13. An edge-directed interpolation method for fetal spine MR images.

    PubMed

    Yu, Shaode; Zhang, Rui; Wu, Shibin; Hu, Jiani; Xie, Yaoqin

    2013-10-10

    Fetal spinal magnetic resonance imaging (MRI) is a prenatal routine for proper assessment of fetus development, especially when suspected spinal malformations occur while ultrasound fails to provide details. Limited by hardware, fetal spine MR images suffer from its low resolution.High-resolution MR images can directly enhance readability and improve diagnosis accuracy. Image interpolation for higher resolution is required in clinical situations, while many methods fail to preserve edge structures. Edge carries heavy structural messages of objects in visual scenes for doctors to detect suspicions, classify malformations and make correct diagnosis. Effective interpolation with well-preserved edge structures is still challenging. In this paper, we propose an edge-directed interpolation (EDI) method and apply it on a group of fetal spine MR images to evaluate its feasibility and performance. This method takes edge messages from Canny edge detector to guide further pixel modification. First, low-resolution (LR) images of fetal spine are interpolated into high-resolution (HR) images with targeted factor by bi-linear method. Then edge information from LR and HR images is put into a twofold strategy to sharpen or soften edge structures. Finally a HR image with well-preserved edge structures is generated. The HR images obtained from proposed method are validated and compared with that from other four EDI methods. Performances are evaluated from six metrics, and subjective analysis of visual quality is based on regions of interest (ROI). All these five EDI methods are able to generate HR images with enriched details. From quantitative analysis of six metrics, the proposed method outperforms the other four from signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), structure similarity index (SSIM), feature similarity index (FSIM) and mutual information (MI) with seconds-level time consumptions (TC). Visual analysis of ROI shows that the proposed method maintains better consistency in edge structures with the original images. The proposed method classifies edge orientations into four categories and well preserves structures. It generates convincing HR images with fine details and is suitable in real-time situations. Iterative curvature-based interpolation (ICBI) method may result in crisper edges, while the other three methods are sensitive to noise and artifacts.

  14. Evaluating the decision accuracy and speed of clinical data visualizations.

    PubMed

    Pieczkiewicz, David S; Finkelstein, Stanley M

    2010-01-01

    Clinicians face an increasing volume of biomedical data. Assessing the efficacy of systems that enable accurate and timely clinical decision making merits corresponding attention. This paper discusses the multiple-reader multiple-case (MRMC) experimental design and linear mixed models as means of assessing and comparing decision accuracy and latency (time) for decision tasks in which clinician readers must interpret visual displays of data. These tools can assess and compare decision accuracy and latency (time). These experimental and statistical techniques, used extensively in radiology imaging studies, offer a number of practical and analytic advantages over more traditional quantitative methods such as percent-correct measurements and ANOVAs, and are recommended for their statistical efficiency and generalizability. An example analysis using readily available, free, and commercial statistical software is provided as an appendix. While these techniques are not appropriate for all evaluation questions, they can provide a valuable addition to the evaluative toolkit of medical informatics research.

  15. Integrating Data Clustering and Visualization for the Analysis of 3D Gene Expression Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Data Analysis and Visualization; nternational Research Training Group ``Visualization of Large and Unstructured Data Sets,'' University of Kaiserslautern, Germany; Computational Research Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA

    2008-05-12

    The recent development of methods for extracting precise measurements of spatial gene expression patterns from three-dimensional (3D) image data opens the way for new analyses of the complex gene regulatory networks controlling animal development. We present an integrated visualization and analysis framework that supports user-guided data clustering to aid exploration of these new complex datasets. The interplay of data visualization and clustering-based data classification leads to improved visualization and enables a more detailed analysis than previously possible. We discuss (i) integration of data clustering and visualization into one framework; (ii) application of data clustering to 3D gene expression data; (iii)more » evaluation of the number of clusters k in the context of 3D gene expression clustering; and (iv) improvement of overall analysis quality via dedicated post-processing of clustering results based on visualization. We discuss the use of this framework to objectively define spatial pattern boundaries and temporal profiles of genes and to analyze how mRNA patterns are controlled by their regulatory transcription factors.« less

  16. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

    PubMed Central

    Jezewski, Janusz; Wrobel, Janusz; Matonia, Adam; Horoba, Krzysztof; Martinek, Radek; Kupka, Tomasz; Jezewski, Michal

    2017-01-01

    Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis. PMID:28559852

  17. Ground-to-air flow visualization using Solar Calcium-K line Background-Oriented Schlieren

    NASA Astrophysics Data System (ADS)

    Hill, Michael A.; Haering, Edward A.

    2017-01-01

    The Calcium-K Eclipse Background-Oriented Schlieren experiment was performed as a proof of concept test to evaluate the effectiveness of using the solar disk as a background to perform the Background-Oriented Schlieren (BOS) method of flow visualization. A ground-based imaging system was equipped with a Calcium-K line optical etalon filter to enable the use of the chromosphere of the sun as the irregular background to be used for BOS. A US Air Force T-38 aircraft performed three supersonic runs which eclipsed the sun as viewed from the imaging system. The images were successfully post-processed using optical flow methods to qualitatively reveal the density gradients in the flow around the aircraft.

  18. SAKURA-viewer: intelligent order history viewer based on two-viewpoint architecture.

    PubMed

    Toyoda, Shuichi; Niki, Noboru; Nishitani, Hiromu

    2007-03-01

    We propose a new intelligent order history viewer applied to consolidating and visualizing data. SAKURA-viewer is a highly effective tool, as: 1) it visualizes both the semantic viewpoint and the temporal viewpoint of patient records simultaneously; 2) it promotes awareness of contextual information among the daily data; and 3) it implements patient-centric data entry methods. This viewer contributes to decrease the user's workload in an order entry system. This viewer is now incorporated into an order entry system being run on an experimental basis. We describe the evaluation of this system using results of a user satisfaction survey, analysis of information consolidation within the database, and analysis of the frequency of use of data entry methods.

  19. Content-Based Medical Image Retrieval

    NASA Astrophysics Data System (ADS)

    Müller, Henning; Deserno, Thomas M.

    This chapter details the necessity for alternative access concepts to the currently mainly text-based methods in medical information retrieval. This need is partly due to the large amount of visual data produced, the increasing variety of medical imaging data and changing user patterns. The stored visual data contain large amounts of unused information that, if well exploited, can help diagnosis, teaching and research. The chapter briefly reviews the history of image retrieval and its general methods before technologies that have been developed in the medical domain are focussed. We also discuss evaluation of medical content-based image retrieval (CBIR) systems and conclude with pointing out their strengths, gaps, and further developments. As examples, the MedGIFT project and the Image Retrieval in Medical Applications (IRMA) framework are presented.

  20. Water surface modeling from a single viewpoint video.

    PubMed

    Li, Chuan; Pickup, David; Saunders, Thomas; Cosker, Darren; Marshall, David; Hall, Peter; Willis, Philip

    2013-07-01

    We introduce a video-based approach for producing water surface models. Recent advances in this field output high-quality results but require dedicated capturing devices and only work in limited conditions. In contrast, our method achieves a good tradeoff between the visual quality and the production cost: It automatically produces a visually plausible animation using a single viewpoint video as the input. Our approach is based on two discoveries: first, shape from shading (SFS) is adequate to capture the appearance and dynamic behavior of the example water; second, shallow water model can be used to estimate a velocity field that produces complex surface dynamics. We will provide qualitative evaluation of our method and demonstrate its good performance across a wide range of scenes.

  1. [Quantitative evaluation of visual gnosis in children with focal brain lesions].

    PubMed

    Pencheva, S; Zaprianova, L

    1983-01-01

    Bearing in mind the opinion of many authors on a great plasticity and interchangeability of the brain cortical functional systems in children the authors have carried out an experiment with 40 children with focal damages of the brain hemispheres, in 20 of whom the right, and in the other 20 the left hemisphere was affected. Use was made of the method of visual gnosis quantitative assessment in the modification of Pencheva and Mavlov (1975). In the children with the focal damages, more or less marked disturbances of the visual gnosis were revealed, however, no statistically significant relationship between the disturbances and the brain side were disclosed. The agnostic disorders were equally frequent in the children of both groups.

  2. An experimental facility for the visual study of turbulent flows.

    NASA Technical Reports Server (NTRS)

    Brodkey, R. S.; Hershey, H. C.; Corino, E. R.

    1971-01-01

    An experimental technique which allows visual observations of the wall area in turbulent pipe flow is described in detail. It requires neither the introduction of any injection or measuring device into the flow nor the presence of a two-phase flow or of a non-Newtonian fluid. The technique involves suspending solid MgO particles of colloidal size in trichloroethylene and photographing their motions near the wall with a high speed movie camera moving with the flow. Trichloroethylene was chosen in order to eliminate the index of refraction problem in a curved wall. Evaluation of the technique including a discussion of limitations is included. Also the technique is compared with previous methods of visual observations of turbulent flow.

  3. Freiburg RNA tools: a central online resource for RNA-focused research and teaching.

    PubMed

    Raden, Martin; Ali, Syed M; Alkhnbashi, Omer S; Busch, Anke; Costa, Fabrizio; Davis, Jason A; Eggenhofer, Florian; Gelhausen, Rick; Georg, Jens; Heyne, Steffen; Hiller, Michael; Kundu, Kousik; Kleinkauf, Robert; Lott, Steffen C; Mohamed, Mostafa M; Mattheis, Alexander; Miladi, Milad; Richter, Andreas S; Will, Sebastian; Wolff, Joachim; Wright, Patrick R; Backofen, Rolf

    2018-05-21

    The Freiburg RNA tools webserver is a well established online resource for RNA-focused research. It provides a unified user interface and comprehensive result visualization for efficient command line tools. The webserver includes RNA-RNA interaction prediction (IntaRNA, CopraRNA, metaMIR), sRNA homology search (GLASSgo), sequence-structure alignments (LocARNA, MARNA, CARNA, ExpaRNA), CRISPR repeat classification (CRISPRmap), sequence design (antaRNA, INFO-RNA, SECISDesign), structure aberration evaluation of point mutations (RaSE), and RNA/protein-family models visualization (CMV), and other methods. Open education resources offer interactive visualizations of RNA structure and RNA-RNA interaction prediction as well as basic and advanced sequence alignment algorithms. The services are freely available at http://rna.informatik.uni-freiburg.de.

  4. Early diagnosis and successful treatment of paraneoplastic melanocytic proliferation

    PubMed Central

    Jansen, Joyce C G; Van Calster, Joachim; Pulido, Jose S; Miles, Sarah L; Vile, Richard G; Van Bergen, Tine; Cassiman, Catherine; Spielberg, Leigh H; Leys, Anita M

    2015-01-01

    Background Paraneoplastic melanocytic proliferation (bilateral diffuse uveal melanocytic proliferation, BDUMP) is a rare but devastating disease that causes progressive visual loss in patients who usually have an occult malignancy. Visual loss occurs as a result of paraneoplastic changes in the uveal tissue. Methods In a masked fashion, the serum of two patients with BDUMP was evaluated for the presence of cultured melanocyte elongation and proliferation (CMEP) factor using cultured human melanocytes. We evaluated the efficacy of plasmapheresis as a treatment modality early in the disease in conjunction with radiation and chemotherapy. Results The serum of the first case patient was investigated after plasmapheresis and did not demonstrate proliferation of cultured human melanocytes. The serum of the second case was evaluated prior to treatment with plasmapheresis and did induce this proliferation. These findings are in accordance with the diminution of CMEP factor after plasmapheresis. Treatment with plasmapheresis managed to stabilise the ocular disease progression in both patients. Conclusions In the past, visual loss due to paraneoplastic melanocytic proliferation was considered progressive and irreversible. We treated two patients successfully with plasmapheresis and demonstrated a relation between CMEP factor in the serum of these patients and proliferation of cultured melanocytes. PMID:25908835

  5. MRI Post-processing in Pre-surgical Evaluation

    PubMed Central

    Wang, Z. Irene; Alexopoulos, Andreas V.

    2016-01-01

    Purpose of Review Advanced MRI post-processing techniques are increasingly used to complement visual analysis and elucidate structural epileptogenic lesions. This review summarizes recent developments in MRI post-processing in the context of epilepsy pre-surgical evaluation, with the focus on patients with unremarkable MRI by visual analysis (i.e., “nonlesional” MRI). Recent Findings Various methods of MRI post-processing have been reported to show additional clinical values in the following areas: (1) lesion detection on an individual level; (2) lesion confirmation for reducing the risk of over reading the MRI; (3) detection of sulcal/gyral morphologic changes that are particularly difficult for visual analysis; and (4) delineation of cortical abnormalities extending beyond the visible lesion. Future directions to improve performance of MRI post-processing include using higher magnetic field strength for better signal and contrast to noise ratio, adopting a multi-contrast frame work, and integration with other noninvasive modalities. Summary MRI post-processing can provide essential value to increase the yield of structural MRI and should be included as part of the presurgical evaluation of nonlesional epilepsies. MRI post-processing allows for more accurate identification/delineation of cortical abnormalities, which should then be more confidently targeted and mapped. PMID:26900745

  6. Research on image complexity evaluation method based on color information

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Duan, Jin; Han, Xue-hui; Xiao, Bo

    2017-11-01

    In order to evaluate the complexity of a color image more effectively and find the connection between image complexity and image information, this paper presents a method to compute the complexity of image based on color information.Under the complexity ,the theoretical analysis first divides the complexity from the subjective level, divides into three levels: low complexity, medium complexity and high complexity, and then carries on the image feature extraction, finally establishes the function between the complexity value and the color characteristic model. The experimental results show that this kind of evaluation method can objectively reconstruct the complexity of the image from the image feature research. The experimental results obtained by the method of this paper are in good agreement with the results of human visual perception complexity,Color image complexity has a certain reference value.

  7. Functional Analysis of Internal Moving Organs Using Super-Resolution Echography

    NASA Astrophysics Data System (ADS)

    Masuda, Kohji; Ishihara, Ken; Nagakura, Toshiaki; Tsuda, Takao; Furukawa, Toshiyuki; Maeda, Hajime; Kumagai, Sadatoshi; Kodama, Shinzo

    1994-05-01

    We have developed super-resolution echography to visualize instantaneous velocity and acceleration of internal organs from time-series echograms recorded by a high-frame-rate echograph. The algorithm for this method involves subtraction of two echograms, dividing the difference by the brightness gradient of the first echogram, and normalization of that result by the time interval between the two echograms. Velocity or acceleration is classified into some suitable colors and superimposed on the original B-mode image. Functional diagnosis of moving organs can be made by visualizing instantaneous velocity. In the case of the heart, hypokinesis can be distinguished from a normal heart by the value and the variation of colored parts representing instantaneous velocity. This can also be applied to the liver to observe pulsatile motion. By visualizing instantaneous acceleration, increase or decrease of velocity can be detected. Throb timing and the location of arrhythmia in a heart can be observed. This method has the possibility of contributing to noninvasive functional and characteristic evaluation.

  8. Visibility Equalizer Cutaway Visualization of Mesoscopic Biological Models.

    PubMed

    Le Muzic, M; Mindek, P; Sorger, J; Autin, L; Goodsell, D; Viola, I

    2016-06-01

    In scientific illustrations and visualization, cutaway views are often employed as an effective technique for occlusion management in densely packed scenes. We propose a novel method for authoring cutaway illustrations of mesoscopic biological models. In contrast to the existing cutaway algorithms, we take advantage of the specific nature of the biological models. These models consist of thousands of instances with a comparably smaller number of different types. Our method constitutes a two stage process. In the first step, clipping objects are placed in the scene, creating a cutaway visualization of the model. During this process, a hierarchical list of stacked bars inform the user about the instance visibility distribution of each individual molecular type in the scene. In the second step, the visibility of each molecular type is fine-tuned through these bars, which at this point act as interactive visibility equalizers. An evaluation of our technique with domain experts confirmed that our equalizer-based approach for visibility specification was valuable and effective for both, scientific and educational purposes.

  9. Visibility Equalizer Cutaway Visualization of Mesoscopic Biological Models

    PubMed Central

    Le Muzic, M.; Mindek, P.; Sorger, J.; Autin, L.; Goodsell, D.; Viola, I.

    2017-01-01

    In scientific illustrations and visualization, cutaway views are often employed as an effective technique for occlusion management in densely packed scenes. We propose a novel method for authoring cutaway illustrations of mesoscopic biological models. In contrast to the existing cutaway algorithms, we take advantage of the specific nature of the biological models. These models consist of thousands of instances with a comparably smaller number of different types. Our method constitutes a two stage process. In the first step, clipping objects are placed in the scene, creating a cutaway visualization of the model. During this process, a hierarchical list of stacked bars inform the user about the instance visibility distribution of each individual molecular type in the scene. In the second step, the visibility of each molecular type is fine-tuned through these bars, which at this point act as interactive visibility equalizers. An evaluation of our technique with domain experts confirmed that our equalizer-based approach for visibility specification was valuable and effective for both, scientific and educational purposes. PMID:28344374

  10. Object-graphs for context-aware visual category discovery.

    PubMed

    Lee, Yong Jae; Grauman, Kristen

    2012-02-01

    How can knowing about some categories help us to discover new ones in unlabeled images? Unsupervised visual category discovery is useful to mine for recurring objects without human supervision, but existing methods assume no prior information and thus tend to perform poorly for cluttered scenes with multiple objects. We propose to leverage knowledge about previously learned categories to enable more accurate discovery, and address challenges in estimating their familiarity in unsegmented, unlabeled images. We introduce two variants of a novel object-graph descriptor to encode the 2D and 3D spatial layout of object-level co-occurrence patterns relative to an unfamiliar region and show that by using them to model the interaction between an image’s known and unknown objects, we can better detect new visual categories. Rather than mine for all categories from scratch, our method identifies new objects while drawing on useful cues from familiar ones. We evaluate our approach on several benchmark data sets and demonstrate clear improvements in discovery over conventional purely appearance-based baselines.

  11. Early Detection of Subclinical Visual Damage After Blast-Mediated TBI Enables Prevention of Chronic Visual Deficit by Treatment With P7C3-S243

    PubMed Central

    Dutca, Laura M.; Stasheff, Steven F.; Hedberg-Buenz, Adam; Rudd, Danielle S.; Batra, Nikhil; Blodi, Frederick R.; Yorek, Matthew S.; Yin, Terry; Shankar, Malini; Herlein, Judith A.; Naidoo, Jacinth; Morlock, Lorraine; Williams, Noelle; Kardon, Randy H.; Anderson, Michael G.; Pieper, Andrew A.; Harper, Matthew M.

    2014-01-01

    Purpose. Traumatic brain injury (TBI) frequently leads to chronic visual dysfunction. The purpose of this study was to investigate the effect of TBI on retinal ganglion cells (RGCs), and to test whether treatment with the novel neuroprotective compound P7C3-S243 could prevent in vivo functional deficits in the visual system. Methods. Blast-mediated TBI was modeled using an enclosed over-pressure blast chamber. The RGC physiology was evaluated using a multielectrode array and pattern electroretinogram (PERG). Histological analysis of RGC dendritic field and cell number were evaluated at the end of the study. Visual outcome measures also were evaluated based on treatment of mice with P7C3-S243 or vehicle control. Results. We show that deficits in neutral position PERG after blast-mediated TBI occur in a temporally bimodal fashion, with temporary recovery 4 weeks after injury followed by chronically persistent dysfunction 12 weeks later. This later time point is associated with development of dendritic abnormalities and irreversible death of RGCs. We also demonstrate that ongoing pathologic processes during the temporary recovery latent period (including abnormalities of RGC physiology) lead to future dysfunction of the visual system. We report that modification of PERG to provocative postural tilt testing elicits changes in PERG measurements that correlate with a key in vitro measures of damage: the spontaneous and light-evoked activity of RGCs. Treatment with P7C3-S243 immediately after injury and throughout the temporary recovery latent period protects mice from developing chronic visual system dysfunction. Conclusions. Provocative PERG testing serves as a noninvasive test in the living organism to identify early damage to the visual system, which may reflect corresponding damage in the brain that is not otherwise detectable by noninvasive means. This provides the basis for developing an earlier diagnostic test to identify patients at risk for developing chronic CNS and visual system damage after TBI at an earlier stage when treatments may be more effective in preventing these sequelae. In addition, treatment with the neuroprotective agent P7C3-S243 after TBI protects from visual system dysfunction after TBI. PMID:25468886

  12. Effect of visual target blurring on accommodation under distance viewing

    NASA Astrophysics Data System (ADS)

    Iwata, Yo; Handa, Tomoya; Ishikawa, Hitoshi

    2018-04-01

    Abstract Purpose To examine the effect of visual target blurring on accommodation. Methods We evaluated the objective refraction values when the visual target (asterisk; 8°) was changed from the state without Gaussian blur (15 s) to the state with Gaussian blur adapted [0(without blur) → 10, 0 → 50, 0 → 100: 15 s each]. Results In Gaussian blur 10, when blurring of the target occurred, refraction value did not change significantly. In Gaussian blur 50 and 100, when blurring of the target occurred, the refraction value became significantly myopic. Conclusion Blurring of the distant visual target results in intervention of accommodation.

  13. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    PubMed

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  14. Feasibility and performance evaluation of generating and recording visual evoked potentials using ambulatory Bluetooth based system.

    PubMed

    Ellingson, Roger M; Oken, Barry

    2010-01-01

    Report contains the design overview and key performance measurements demonstrating the feasibility of generating and recording ambulatory visual stimulus evoked potentials using the previously reported custom Complementary and Alternative Medicine physiologic data collection and monitoring system, CAMAS. The methods used to generate visual stimuli on a PDA device and the design of an optical coupling device to convert the display to an electrical waveform which is recorded by the CAMAS base unit are presented. The optical sensor signal, synchronized to the visual stimulus emulates the brain's synchronized EEG signal input to CAMAS normally reviewed for the evoked potential response. Most importantly, the PDA also sends a marker message over the wireless Bluetooth connection to the CAMAS base unit synchronized to the visual stimulus which is the critical averaging reference component to obtain VEP results. Results show the variance in the latency of the wireless marker messaging link is consistent enough to support the generation and recording of visual evoked potentials. The averaged sensor waveforms at multiple CPU speeds are presented and demonstrate suitability of the Bluetooth interface for portable ambulatory visual evoked potential implementation on our CAMAS platform.

  15. Semantics by analogy for illustrative volume visualization☆

    PubMed Central

    Gerl, Moritz; Rautek, Peter; Isenberg, Tobias; Gröller, Eduard

    2012-01-01

    We present an interactive graphical approach for the explicit specification of semantics for volume visualization. This explicit and graphical specification of semantics for volumetric features allows us to visually assign meaning to both input and output parameters of the visualization mapping. This is in contrast to the implicit way of specifying semantics using transfer functions. In particular, we demonstrate how to realize a dynamic specification of semantics which allows to flexibly explore a wide range of mappings. Our approach is based on three concepts. First, we use semantic shader augmentation to automatically add rule-based rendering functionality to static visualization mappings in a shader program, while preserving the visual abstraction that the initial shader encodes. With this technique we extend recent developments that define a mapping between data attributes and visual attributes with rules, which are evaluated using fuzzy logic. Second, we let users define the semantics by analogy through brushing on renderings of the data attributes of interest. Third, the rules are specified graphically in an interface that provides visual clues for potential modifications. Together, the presented methods offer a high degree of freedom in the specification and exploration of rule-based mappings and avoid the limitations of a linguistic rule formulation. PMID:23576827

  16. Bag-of-visual-ngrams for histopathology image classification

    NASA Astrophysics Data System (ADS)

    López-Monroy, A. Pastor; Montes-y-Gómez, Manuel; Escalante, Hugo Jair; Cruz-Roa, Angel; González, Fabio A.

    2013-11-01

    This paper describes an extension of the Bag-of-Visual-Words (BoVW) representation for image categorization (IC) of histophatology images. This representation is one of the most used approaches in several high-level computer vision tasks. However, the BoVW representation has an important limitation: the disregarding of spatial information among visual words. This information may be useful to capture discriminative visual-patterns in specific computer vision tasks. In order to overcome this problem we propose the use of visual n-grams. N-grams based-representations are very popular in the field of natural language processing (NLP), in particular within text mining and information retrieval. We propose building a codebook of n-grams and then representing images by histograms of visual n-grams. We evaluate our proposal in the challenging task of classifying histopathology images. The novelty of our proposal lies in the fact that we use n-grams as attributes for a classification model (together with visual-words, i.e., 1-grams). This is common practice within NLP, although, to the best of our knowledge, this idea has not been explored yet within computer vision. We report experimental results in a database of histopathology images where our proposed method outperforms the traditional BoVWs formulation.

  17. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  18. [A cross-sectional study of moderate or severe visual impairment and blindness in residents with type 2 diabetes living in Xinjing Town, Shanghai].

    PubMed

    Bai, X L; Xu, X; Lu, M; He, J N; Xu, X; Du, X; Zhang, B; He, X G; Lu, L N; Zhu, J F; Zou, H D; Zhao, J L

    2016-11-11

    Objective: To investigate the prevalence, underlying causes and risk factors of moderate or severe visual impairment and blindness in a population with type 2 diabetes in Xinjing Town, Shanghai, China. Methods: A cross-sectional survey among local Han adult residents, who were previously diagnosed as type 2 diabetes, was conducted between October 2014 and January 2015. The survey was preceded by a pilot study; operational methods were refined and quality assurance evaluation was carried out. The best corrected visual acuity was recorded and classified following the modified World Health Organization grading system. Assigned ophthalmic doctors assured the leading causes of every blind or visually impaired eye. Binary logistic regression analysis was used to determine the related factors of blindness and moderate or severe visual impairment. Results: A total of 2 216 type 2 diabetic residents were enrolled, and 166 eyes (3.7%, 166/4 432) were blind. Cataract was the leading cause of blindness (39.8%); macular degeneration (18.0%) and eyeball atrophy (11.4%) were the second and third leading causes of blindness, respectively. Moderate or severe visual impairment was found in 376 eyes (8.5%, 376/4 432), and the most frequent cause was cataract (65.7%), followed by diabetic retinopathy (9.8%) and macular degeneration (9.4% ). Older age, female gender, earlier onset diabetes and a lower spherical equivalent in the better eye were associated with best corrected visual acuity<20/63 in the better eye. Conclusion: The prevalences of moderate or severe visual impairment and blindness in our population with type 2 diabetes were high. (Chin J Ophthalmol, 2016, 52: 825-830) .

  19. A robust pointer segmentation in biomedical images toward building a visual ontology for biomedical article retrieval

    NASA Astrophysics Data System (ADS)

    You, Daekeun; Simpson, Matthew; Antani, Sameer; Demner-Fushman, Dina; Thoma, George R.

    2013-01-01

    Pointers (arrows and symbols) are frequently used in biomedical images to highlight specific image regions of interest (ROIs) that are mentioned in figure captions and/or text discussion. Detection of pointers is the first step toward extracting relevant visual features from ROIs and combining them with textual descriptions for a multimodal (text and image) biomedical article retrieval system. Recently we developed a pointer recognition algorithm based on an edge-based pointer segmentation method, and subsequently reported improvements made on our initial approach involving the use of Active Shape Models (ASM) for pointer recognition and region growing-based method for pointer segmentation. These methods contributed to improving the recall of pointer recognition but not much to the precision. The method discussed in this article is our recent effort to improve the precision rate. Evaluation performed on two datasets and compared with other pointer segmentation methods show significantly improved precision and the highest F1 score.

  20. Task-specific usability requirements of electronic medical records systems: Lessons learned from a national survey of end-users.

    PubMed

    Farzandipour, Mehrdad; Meidani, Zahra; Riazi, Hossein; Sadeqi Jabali, Monireh

    2018-09-01

    There are various approaches to evaluating the usability of electronic medical record (EMR) systems. User perspectives are an integral part of evaluation. Usability evaluations efficiently and effectively contribute to user-centered design and supports tasks and increase user satisfaction. This study determined the main usability requirements for EMRs by means of an end-user survey. A mixed-method strategy was conducted in three phases. A qualitative approach was employed to collect and formulate EMR usability requirements using the focus group method and the modified Delphi technique. Classic Delphi technique was used to evaluate the proposed requirements among 380 end-users in Iran. The final list of EMR usability requirements was verified and included 163 requirements divided into nine groups. The highest rates of end-user agreement relate to EMR visual clarity (3.65 ± 0.61), fault tolerance (3.58 ± 0.56), and suitability for learning (3.55 ± 0.54). The lowest end-user agreement was for auditory presentation (3.18 ± 0.69). The highest and lowest agreement among end-users was for visual clarity and auditory presentation by EMRs, respectively. This suggests that user priorities in determination of EMR usability and their understanding of the importance of the types of individual tasks and context characteristics differ.

  1. Scientific Process Flowchart Assessment (SPFA): A Method for Evaluating Changes in Understanding and Visualization of the Scientific Process in a Multidisciplinary Student Population

    PubMed Central

    Wilson, Kristy J.; Rigakos, Bessie

    2016-01-01

    The scientific process is nonlinear, unpredictable, and ongoing. Assessing the nature of science is difficult with methods that rely on Likert-scale or multiple-choice questions. This study evaluated conceptions about the scientific process using student-created visual representations that we term “flowcharts.” The methodology, Scientific Process Flowchart Assessment (SPFA), consisted of a prompt and rubric that was designed to assess students’ understanding of the scientific process. Forty flowcharts representing a multidisciplinary group without intervention and 26 flowcharts representing pre- and postinstruction were evaluated over five dimensions: connections, experimental design, reasons for doing science, nature of science, and interconnectivity. Pre to post flowcharts showed a statistically significant improvement in the number of items and ratings for the dimensions. Comparison of the terms used and connections between terms on student flowcharts revealed an enhanced and more nuanced understanding of the scientific process, especially in the areas of application to society and communication within the scientific community. We propose that SPFA can be used in a variety of circumstances, including in the determination of what curricula or interventions would be useful in a course or program, in the assessment of curriculum, or in the evaluation of students performing research projects. PMID:27856551

  2. Methods for Creating and Animating a Computer Model Depicting the Structure and Function of the Sarcoplasmic Reticulum Calcium ATPase Enzyme.

    ERIC Educational Resources Information Center

    Chen, Alice Y.; McKee, Nancy

    1999-01-01

    Describes the developmental process used to visualize the calcium ATPase enzyme of the sarcoplasmic reticulum which involves evaluating scientific information, consulting scientists, model making, storyboarding, and creating and editing in a computer medium. (Author/CCM)

  3. Eutrophication of an Urban Forest Ecosystem: Causes and Effects

    NASA Astrophysics Data System (ADS)

    Bednova, O. V.; Kuznetsov, V. A.; Tarasova, N. P.

    2018-01-01

    The combined use of methods of passive dosimetry of the status of atmospheric air, phytoindication, and cartographic visualization of data made it possible to elaborate and substantiate approaches to evaluation of the effect of atmospheric air contamination on the eutrophication of forest ecosystems under urban conditions.

  4. Tactile Radar: experimenting a computer game with visually disabled.

    PubMed

    Kastrup, Virgínia; Cassinelli, Alvaro; Quérette, Paulo; Bergstrom, Niklas; Sampaio, Eliana

    2017-09-18

    Visually disabled people increasingly use computers in everyday life, thanks to novel assistive technologies better tailored to their cognitive functioning. Like sighted people, many are interested in computer games - videogames and audio-games. Tactile-games are beginning to emerge. The Tactile Radar is a device through which a visually disabled person is able to detect distal obstacles. In this study, it is connected to a computer running a tactile-game. The game consists in finding and collecting randomly arranged coins in a virtual room. The study was conducted with nine congenital blind people including both sexes, aged 20-64 years old. Complementary methods of first and third person were used: the debriefing interview and the quasi-experimental design. The results indicate that the Tactile Radar is suitable for the creation of computer games specifically tailored for visually disabled people. Furthermore, the device seems capable of eliciting a powerful immersive experience. Methodologically speaking, this research contributes to the consolidation and development of first and third person complementary methods, particularly useful in disabled people research field, including the evaluation by users of the Tactile Radar effectiveness in a virtual reality context. Implications for rehabilitation Despite the growing interest in virtual games for visually disabled people, they still find barriers to access such games. Through the development of assistive technologies such as the Tactile Radar, applied in virtual games, we can create new opportunities for leisure, socialization and education for visually disabled people. The results of our study indicate that the Tactile Radar is adapted to the creation of video games for visually disabled people, providing a playful interaction with the players.

  5. Unified Multimodal Measurement for Performance Indication Research, Evaluation, and Effectiveness (UMMPIREE): Phase I Report

    DTIC Science & Technology

    2018-01-25

    generally a researcher into methods and techniques (i.e., the science) of assessment. This stakeholder may observe ongoing events/experiments or may use... Research Visualization Tool. A first step toward finding a method to link research . 3.1.2 Phase II: Linking and the Network Approach During Phase I, we...innovations. In the former realm, UMMPIREE will develop a method to link assessments from different research studies to guide research

  6. Evaluation of Hydroxychloroquine Retinopathy With Multifocal Electroretinography

    PubMed Central

    So, Scott C.; Hedges, Thomas R.; Schuman, Joel S.; Quireza, Maria Luz Amaro

    2007-01-01

    BACKGROUND AND OBJECTIVE To describe the changes revealed by multifocal electroretinography (ERG) in patients taking hydroxychloroquine. PATIENTS AND METHODS Six patients being treated for various inflammatory conditions with hydroxychloroquine for periods ranging from 8 months to 7 years were consecutively evaluated. Each examination included measurement of Snellen visual acuities, Amsler grid assessment, and automated visual field testing. In some cases, funduscopic examinations were complimented by photography and fluorescein angiography. Multifocal ERG was performed for all patients. RESULTS Three patients (six eyes) were found to have distinctive abnormalities on multifocal ERG consisting of pericentral depression of ERG signals. The abnormalities on multifocal ERG corresponded with the patients’ subjective descriptions and the visual field depiction of their pericentral scotomas. All affected patients had been taking hydroxychloroquine for at least 7 years. One patient with generalized depression on multifocal ERG had possible hydroxychloroquine retinopathy. Two patients (three eyes) had relatively normal results on multifocal ERG. CONCLUSION Multifocal ERG objectively demonstrates depression of signals in the perifoveal region in visually symptomatic patients with long-term hydroxychloroquine use. Even patients with normal visual acuity and no fundus abnormalities can have abnormal results. Although we have not yet identified patients with abnormalities on multifocal ERG before the onset of symptoms, multifocal ERG may be useful in monitoring patients at risk and may provide an earlier opportunity to identify maculopathy. PMID:12757106

  7. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    PubMed Central

    Unsal, Ugur; Baser, Gonen

    2016-01-01

    Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560

  8. Visual feature discrimination versus compression ratio for polygonal shape descriptors

    NASA Astrophysics Data System (ADS)

    Heuer, Joerg; Sanahuja, Francesc; Kaup, Andre

    2000-10-01

    In the last decade several methods for low level indexing of visual features appeared. Most often these were evaluated with respect to their discrimination power using measures like precision and recall. Accordingly, the targeted application was indexing of visual data within databases. During the standardization process of MPEG-7 the view on indexing of visual data changed, taking also communication aspects into account where coding efficiency is important. Even if the descriptors used for indexing are small compared to the size of images, it is recognized that there can be several descriptors linked to an image, characterizing different features and regions. Beside the importance of a small memory footprint for the transmission of the descriptor and the memory footprint in a database, eventually the search and filtering can be sped up by reducing the dimensionality of the descriptor if the metric of the matching can be adjusted. Based on a polygon shape descriptor presented for MPEG-7 this paper compares the discrimination power versus memory consumption of the descriptor. Different methods based on quantization are presented and their effect on the retrieval performance are measured. Finally an optimized computation of the descriptor is presented.

  9. Neuroplus biofeedback improves attention, resilience, and injury prevention in elite soccer players.

    PubMed

    Rusciano, Aiace; Corradini, Giuliano; Stoianov, Ivilin

    2017-06-01

    Performance and injury prevention in elite soccer players are typically investigated from physical-tactical, biomechanical, and metabolic perspectives. However, executive functions, visuospatial abilities, and psychophysiological adaptability or resilience are also fundamental for efficiency and well-being in sports. Based on previous research associating autonomic flexibility with prefrontal cortical control, we designed a novel integrated autonomic biofeedback training method called Neuroplus to improve resilience, visual attention, and injury prevention. Herein, we introduce the method and provide an evaluation of 20 elite soccer players from the Italian Soccer High Division (Serie-A): 10 players trained with Neuroplus and 10 trained with a control treatment. The assessments included psychophysiological stress profiles, a visual search task, and indexes of injury prevention, which were measured pre- and posttreatment. The analysis showed a significant enhancement of physiological adaptability, recovery following stress, visual selective attention, and injury prevention that were specific to the Neuroplus group. Enhancing the interplay between autonomic and cognitive functions through biofeedback may become a key principle for obtaining excellence and well-being in sports. To our knowledge, this is the first evidence that shows improvement in visual selective attention following intense autonomic biofeedback. © 2017 Society for Psychophysiological Research.

  10. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    NASA Astrophysics Data System (ADS)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  11. Improved Diagnostic Accuracy of SPECT Through Statistical Analysis and the Detection of Hot Spots at the Primary Sensorimotor Area for the Diagnosis of Alzheimer Disease in a Community-Based Study: "The Osaki-Tajiri Project".

    PubMed

    Kaneta, Tomohiro; Nakatsuka, Masahiro; Nakamura, Kei; Seki, Takashi; Yamaguchi, Satoshi; Tsuboi, Masahiro; Meguro, Kenichi

    2016-01-01

    SPECT is an important diagnostic tool for dementia. Recently, statistical analysis of SPECT has been commonly used for dementia research. In this study, we evaluated the accuracy of visual SPECT evaluation and/or statistical analysis for the diagnosis (Dx) of Alzheimer disease (AD) and other forms of dementia in our community-based study "The Osaki-Tajiri Project." Eighty-nine consecutive outpatients with dementia were enrolled and underwent brain perfusion SPECT with 99mTc-ECD. Diagnostic accuracy of SPECT was tested using 3 methods: visual inspection (SPECT Dx), automated diagnostic tool using statistical analysis with easy Z-score imaging system (eZIS Dx), and visual inspection plus eZIS (integrated Dx). Integrated Dx showed the highest sensitivity, specificity, and accuracy, whereas eZIS was the second most accurate method. We also observed that a higher than expected rate of SPECT images indicated false-negative cases of AD. Among these, 50% showed hypofrontality and were diagnosed as frontotemporal lobar degeneration. These cases typically showed regional "hot spots" in the primary sensorimotor cortex (ie, a sensorimotor hot spot sign), which we determined were associated with AD rather than frontotemporal lobar degeneration. We concluded that the diagnostic abilities were improved by the integrated use of visual assessment and statistical analysis. In addition, the detection of a sensorimotor hot spot sign was useful to detect AD when hypofrontality is present and improved the ability to properly diagnose AD.

  12. Influence of outdoor advertisement colors on psychological evaluation of townscape in Kyoto

    NASA Astrophysics Data System (ADS)

    Onishi, Ayumi; Ishida, Taiichiro; Katsuya, Yoshiko

    2002-06-01

    Outdoor advertisements must be one of the major factors that affect our psychological impression for townscapes. They often conflict with propr color environments in cities particularly in historic cities like Kyoto. In this study we investigated how outdoor advertisements influenced our visual evaluation of townscapes in Kyoto. In recent years, a new regulation for outdoor advertisements came into operation in Kyoto and some of the advertisements have been replaced or removed gradually. We examined psychological evaluation for the townscapes before and after their changes. In the experiment, subjects evaluated 'visual harmony,' 'visual busyness,' 'visual comfort' and 'suitability to Kyoto' of townscapes projected on a screen. The results indicated that the evaluation of 'visual busyness' significantly decreased with the amount of the advertisements. The relations between the advertisements and the psychological evaluation of the townscape are discussed.

  13. Preliminary study on the inactivation of anisakid larvae in baccalà prepared according to traditional methods.

    PubMed

    Smaldone, Giorgio; Marrone, Raffaele; Palma, Giuseppe; Sarnelli, Paolo; Anastasio, Aniello

    2017-10-20

    The European Food Safety Authority stated that many traditional marinating and cold smoking methods are not sufficient to kill A. simplex and asked to evaluate alternative treatments for killing viable parasites in fishery . Baccalà is a well-liked traditional product. The aim of study was to evaluate the effectiveness of the salting process on the inactivation of nematodes of the genus Anisakis in naturally infected Baccalà fillets. N. 19 fillets, subjected to a dual salting process (brine and dry salting) were analyzed. Visual inspection and chloropeptic digestion were performed. Larvae viability was evaluated, and parameters such as NaCl (%), moisture (%), WPS and a w were determined. In n. 17 samples parasites were found 123 parasites with a mean intensity of 7.23±4.78 and an mean abundance of 6.47±5.05. Visual examination has revealed 109 parasites. 61.8% of larvae were found in the ventral portions. The results show that salting process with a salt concentration of 18.6%, a w values of 0.7514 and 24.15% WPS in all parts of baccalà fillets, devitalise Anisakidae larvae in a 15-day period.

  14. Preliminary study on the inactivation of anisakid larvae in baccalà prepared according to traditional methods

    PubMed Central

    Smaldone, Giorgio; Marrone, Raffaele; Palma, Giuseppe; Sarnelli, Paolo; Anastasio, Aniello

    2017-01-01

    The European Food Safety Authority stated that many traditional marinating and cold smoking methods are not sufficient to kill A. simplex and asked to evaluate alternative treatments for killing viable parasites in fishery. Baccalà is a well-liked traditional product. The aim of study was to evaluate the effectiveness of the salting process on the inactivation of nematodes of the genus Anisakis in naturally infected Baccalà fillets. N. 19 fillets, subjected to a dual salting process (brine and dry salting) were analyzed. Visual inspection and chloropeptic digestion were performed. Larvae viability was evaluated, and parameters such as NaCl (%), moisture (%), WPS and aw were determined. In n. 17 samples parasites were found 123 parasites with a mean intensity of 7.23±4.78 and an mean abundance of 6.47±5.05. Visual examination has revealed 109 parasites. 61.8% of larvae were found in the ventral portions. The results show that salting process with a salt concentration of 18.6%, aw values of 0.7514 and 24.15% WPS in all parts of baccalà fillets, devitalise Anisakidae larvae in a 15-day period. PMID:29564240

  15. Semiquantitative visual approach to scoring lung cancer treatment response using computed tomography: a pilot study.

    PubMed

    Gottlieb, Ronald H; Kumar, Prasanna; Loud, Peter; Klippenstein, Donald; Raczyk, Cheryl; Tan, Wei; Lu, Jenny; Ramnath, Nithya

    2009-01-01

    Our objective was to compare a newly developed semiquantitative visual scoring (SVS) method with the current standard, the Response Evaluation Criteria in Solid Tumors (RECIST) method, in the categorization of treatment response and reader agreement for patients with metastatic lung cancer followed by computed tomography. The 18 subjects (5 women and 13 men; mean age, 62.8 years) were from an institutional review board-approved phase 2 study that evaluated a second-line chemotherapy regimen for metastatic (stages III and IV) non-small cell lung cancer. Four radiologists, blinded to the patient outcome and each other's reads, evaluated the change in the patients' tumor burden from the baseline to the first restaging computed tomographic scan using either the RECIST or the SVS method. We compared the numbers of patients placed into the partial response, the stable disease (SD), and the progressive disease (PD) categories (Fisher exact test) and observer agreement (kappa statistic). Requiring the concordance of 3 of the 4 readers resulted in the RECIST placing 17 (100%) of 17 patients in the SD category compared with the SVS placing 9 (60%) of 15 patients in the partial response, 5 (33%) of the 15 patients in the SD, and 1 (6.7%) of the 15 patients in the PD categories (P < 0.0001). Interobserver agreement was higher among the readers using the SVS method (kappa, 0.54; P < 0.0001) compared with that of the readers using the RECIST method (kappa, -0.01; P = 0.5378). Using the SVS method, the readers more finely discriminated between the patient response categories with superior agreement compared with the RECIST method, which could potentially result in large differences in early treatment decisions for advanced lung cancer.

  16. Caries Detection around Restorations Using ICDAS and Optical Devices.

    PubMed

    Diniz, Michele Baffi; Eckert, George Joseph; González-Cabezas, Carlos; Cordeiro, Rita de Cássia Loiola; Ferreira-Zandona, Andrea Gonçalves

    2016-01-01

    Secondary caries is the major reason for replacement of restorations in operative dentistry. New detection methods and technology have the potential to improve the accuracy for diagnosis of secondary carious lesions. This in vitro study evaluated the performance of the ICDAS (International Caries Detection and Assessment System) visual criteria and optical devices for detecting secondary caries around amalgam and composite resin restorations in permanent teeth. A total of 180 extracted teeth with Class I amalgam (N = 90) and resin composite (N = 90) restorations were selected. Two examiners analyzed the teeth twice using the visual criteria (ICDAS), laser fluorescence (LF), light-emitting diode device (MID), quantitative light-induced fluorescence system (QLF), and a prototype system based on the Fluorescence Enamel Imaging technique (Professional Caries Detection System, PCDS). The gold standard was determined by means of confocal laser scanning microscopy. High-reproducibility values were shown for all methods, except for MID in the amalgam group. For both groups the QLF and PCDS were the most sensitive methods, whereas the other methods presented better specificity (p < 0.05). All methods, except the MID device appeared to be potential methods for detecting secondary caries only around resin composite restorations, whereas around amalgam restorations all methods seemed to be questionable. Using Internal Caries Detection and Assessment System (ICDAS), an LF device, quantitative light-induced fluorescence and a novel method based on Fluorescence Enamel Imaging technique may be effective for evaluating secondary caries around composite resin restorations. © 2016 Wiley Periodicals, Inc.

  17. Extracting alpha band modulation during visual spatial attention without flickering stimuli using common spatial pattern.

    PubMed

    Fujisawa, Junya; Touyama, Hideaki; Hirose, Michitaka

    2008-01-01

    In this paper, alpha band modulation during visual spatial attention without visual stimuli was focused. Visual spatial attention has been expected to provide a new channel of non-invasive independent brain computer interface (BCI), but little work has been done on the new interfacing method. The flickering stimuli used in previous work cause a decline of independency and have difficulties in a practical use. Therefore we investigated whether visual spatial attention could be detected without such stimuli. Further, the common spatial patterns (CSP) were for the first time applied to the brain states during visual spatial attention. The performance evaluation was based on three brain states of left, right and center direction attention. The 30-channel scalp electroencephalographic (EEG) signals over occipital cortex were recorded for five subjects. Without CSP, the analyses made 66.44 (range 55.42 to 72.27) % of average classification performance in discriminating left and right attention classes. With CSP, the averaged classification accuracy was 75.39 (range 63.75 to 86.13) %. It is suggested that CSP is useful in the context of visual spatial attention, and the alpha band modulation during visual spatial attention without flickering stimuli has the possibility of a new channel for independent BCI as well as motor imagery.

  18. Visual field defects may not affect safe driving.

    PubMed

    Dow, Jamie

    2011-10-01

    In Quebec a driver whose acquired visual field defect renders them ineligible for a driver's permit renewal may request an exemption from the visual field standard by demonstrating safe driving despite the defect. For safety reasons it was decided to attempt to identify predictors of failure on the road test in order to avoid placing driving evaluators in potentially dangerous situations when evaluating drivers with visual field defects. During a 4-month period in 2009 all requests for exemptions from the visual field standard were collected and analyzed. All available medical and visual field data were collated for 103 individuals, of whom 91 successfully completed the evaluation process and obtained a waiver. The collated data included age, sex, type of visual field defect, visual field characteristics, and concomitant medical problems. No single factor, or combination of factors, could predict failure of the road test. All 5 failures of the road test had cognitive problems but 6 of the successful drivers also had known cognitive problems. Thus, cognitive problems influence the risk of failure but do not predict certain failure. Most of the applicants for an exemption were able to complete the evaluation process successfully, thereby demonstrating safe driving despite their handicap. Consequently, jurisdictions that have visual field standards for their driving permit should implement procedures to evaluate drivers with visual field defects that render them unable to meet the standard but who wish to continue driving.

  19. TOWARD QUANTITATIVE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY: Visualizing Blood Flow Speeds in Ocular Pathology Using Variable Interscan Time Analysis.

    PubMed

    Ploner, Stefan B; Moult, Eric M; Choi, WooJhon; Waheed, Nadia K; Lee, ByungKun; Novais, Eduardo A; Cole, Emily D; Potsaid, Benjamin; Husvogt, Lennart; Schottenhamml, Julia; Maier, Andreas; Rosenfeld, Philip J; Duker, Jay S; Hornegger, Joachim; Fujimoto, James G

    2016-12-01

    Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.

  20. [Development of a standardized evaluation system for cataracta complicata in retinitis pigmentosa].

    PubMed

    Auffarth, G U; Faller, U; Tetz, M R; Krastel, H; Völcker, H E

    1997-07-01

    Retinitis pigmentosa (RP) is associated with the formation of a posterior subcapsular cataract (PSC). As only a small part of the crystalline lens is usually affected, it is sometimes difficult to determine to what extent the visual loss is caused by the PSC alone. The methodology was developed in analogy to a scoring system for posterior capsule opacification by Tetz et al. Following dilation of the pupil, standardized photographs of the anterior segments were obtained utilizing a Zeiss photoslitlamp model 40 SL/P. The PSC was scored by evaluating retroillumination photographs. The individual PSC index was calculated by multiplying the density of the opacification (graded from 0 to 4) by the area involved in the central 4 mm zone of the pupil (calculated between 0 and 1). For testing the reliability of the evaluation system in part 1 of this study, 11 RP patients with different grades of PSC were examined by three independent observers. In part 2 of this study 37 eyes of 24 RP patients, aged 47.2 +/- 11.8 years, were evaluated and the PSC index was correlated with different parameters (visual acuity, age, visual fields, eletroretinography). RESULTS PART 1: The cataract-density grades were between 1 and 4 in the 11 patients. In relation to the central 4-mm pupillary zone between 13 and 100% of the area were opacified. Cataract indices (density x area) were between 0.13 and 4.0 (Mean values: Examiner 1:1.41 +/- 1.49; Examiner 2:1.28 +/- 1.46; Examiner 3:1.22 +/- 1.44; differences not significant: P = 0.77). PART 2: After an average duration of RP of 23 years, the average cataract index of the 24 patients was 1.72 +/- 1.35. There was no correlation between cataract index and ERG or visual fields (r < 0.2; P > 0.4); however, there was a good correlation to visual acuity (r = -0.72; P = 0.0001). Patients with early onset of RP (before 20th year of life) presented on average with an higher cataract index (2.06 +/- 1.67) compared to patients with late manifestation (0.61 +/- 0.44), but equivalent duration of RP. The evaluation system offers a reliable and reproducible method for measuring PSC density and extension in RP patients. The method can serve as a useful tool for documenting PSC development and help to define the indications for cataract surgery in RP.

Top