Sample records for visual field defect

  1. Automated objective characterization of visual field defects in 3D

    NASA Technical Reports Server (NTRS)

    Fink, Wolfgang (Inventor)

    2006-01-01

    A method and apparatus for electronically performing a visual field test for a patient. A visual field test pattern is displayed to the patient on an electronic display device and the patient's responses to the visual field test pattern are recorded. A visual field representation is generated from the patient's responses. The visual field representation is then used as an input into a variety of automated diagnostic processes. In one process, the visual field representation is used to generate a statistical description of the rapidity of change of a patient's visual field at the boundary of a visual field defect. In another process, the area of a visual field defect is calculated using the visual field representation. In another process, the visual field representation is used to generate a statistical description of the volume of a patient's visual field defect.

  2. The accuracy of confrontation visual field test in comparison with automated perimetry.

    PubMed Central

    Johnson, L. N.; Baloh, F. G.

    1991-01-01

    The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764

  3. Anosognosia for obvious visual field defects in stroke patients.

    PubMed

    Baier, Bernhard; Geber, Christian; Müller-Forell, Wiebke; Müller, Notger; Dieterich, Marianne; Karnath, Hans-Otto

    2015-01-01

    Patients with anosognosia for visual field defect (AVFD) fail to recognize consciously their visual field defect. There is still unclarity whether specific neural correlates are associated with AVFD. We studied AVFD in 54 patients with acute stroke and a visual field defect. Nineteen percent of this unselected sample showed AVFD. By using modern voxelwise lesion-behaviour mapping techniques we found an association between AVFD and parts of the lingual gyrus, the cuneus as well as the posterior cingulate and corpus callosum. Damage to these regions appears to induce unawareness of visual field defects and thus may play a significant role for conscious visual perception.

  4. The SCHEIE Visual Field Grading System

    PubMed Central

    Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan

    2017-01-01

    Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621

  5. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  6. Visual field defects may not affect safe driving.

    PubMed

    Dow, Jamie

    2011-10-01

    In Quebec a driver whose acquired visual field defect renders them ineligible for a driver's permit renewal may request an exemption from the visual field standard by demonstrating safe driving despite the defect. For safety reasons it was decided to attempt to identify predictors of failure on the road test in order to avoid placing driving evaluators in potentially dangerous situations when evaluating drivers with visual field defects. During a 4-month period in 2009 all requests for exemptions from the visual field standard were collected and analyzed. All available medical and visual field data were collated for 103 individuals, of whom 91 successfully completed the evaluation process and obtained a waiver. The collated data included age, sex, type of visual field defect, visual field characteristics, and concomitant medical problems. No single factor, or combination of factors, could predict failure of the road test. All 5 failures of the road test had cognitive problems but 6 of the successful drivers also had known cognitive problems. Thus, cognitive problems influence the risk of failure but do not predict certain failure. Most of the applicants for an exemption were able to complete the evaluation process successfully, thereby demonstrating safe driving despite their handicap. Consequently, jurisdictions that have visual field standards for their driving permit should implement procedures to evaluate drivers with visual field defects that render them unable to meet the standard but who wish to continue driving.

  7. Reading performance after vision rehabilitation of subjects with homonymous visual field defects.

    PubMed

    Gall, Carolin; Sabel, Bernhard A

    2012-12-01

    To examine whether increased visual functioning after vision-restoration training (VRT) coincides with improved reading abilities. Prospective noncontrolled open-label trial. Controlled laboratory setting for all diagnostic procedures that were conducted before and after 6 months of home-based VRT with telemedicine support. Eleven subjects who had experienced a posterior-parietal stroke and have homonymous visual field defects. Six months of VRT (1 hour daily repeated light stimulation in the partially damaged visual field). VRT outcome measures were the number of detected light stimuli in eye-tracker controlled high-resolution perimetry and the spared visual field within the affected hemifield up to the relative and absolute defect visual field border (square degrees). Enlargements of spared visual field within the affected hemifield were correlated with changes of reading speed after VRT. After VRT, the number of detected light stimuli increased by 5.02 ± 4.31% (mean ± SD; P = .03). The spared visual field up to the relative defect visual field border increased from 18.09 ± 32.35 square degrees before to 137.40 ± 53.32 after VRT (P = .006), as well as for the absolute defect visual field border from 36.95 ± 33.77 square degrees before VRT to 152.02 ± 49.70 after VRT (P = .005). Reading speed increased from 108.95 ± 33.95 words per minute before VRT to 122.26 ± 30.35 after VRT (P = .017), which significantly correlated with increased spared visual field up to the relative defect visual field border (r = 0.73, P = .016). Measures of eye movement variability did not correlate with VRT outcome. VRT improved visual fields in parafoveal areas, which are most relevant for reading. This finding cannot be explained by changes in eye movement behavior. Because of a significant association between improvements of parafoveal vision and reading speed, we propose that patients with homonymous visual field defects who have reading deficits may benefit from visual stimulation by training. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. The efficacy of a novel mobile phone application for goldmann ptosis visual field interpretation.

    PubMed

    Maamari, Robi N; D'Ambrosio, Michael V; Joseph, Jeffrey M; Tao, Jeremiah P

    2014-01-01

    To evaluate the efficacy of a novel mobile phone application that calculates superior visual field defects on Goldmann visual field charts. Experimental study in which the mobile phone application and 14 oculoplastic surgeons interpreted the superior visual field defect in 10 Goldmann charts. Percent error of the mobile phone application and the oculoplastic surgeons' estimates were calculated compared with computer software computation of the actual defects. Precision and time efficiency of the application were evaluated by processing the same Goldmann visual field chart 10 repeated times. The mobile phone application was associated with a mean percent error of 1.98% (95% confidence interval[CI], 0.87%-3.10%) in superior visual field defect calculation. The average mean percent error of the oculoplastic surgeons' visual estimates was 19.75% (95% CI, 14.39%-25.11%). Oculoplastic surgeons, on average, underestimated the defect in all 10 Goldmann charts. There was high interobserver variance among oculoplastic surgeons. The percent error of the 10 repeated measurements on a single chart was 0.93% (95% CI, 0.40%-1.46%). The average time to process 1 chart was 12.9 seconds (95% CI, 10.9-15.0 seconds). The mobile phone application was highly accurate, precise, and time-efficient in calculating the percent superior visual field defect using Goldmann charts. Oculoplastic surgeon visual interpretations were highly inaccurate, highly variable, and usually underestimated the field vision loss.

  9. Active Learning in Neuroscience: A Manipulative to Simulate Visual Field Defects

    ERIC Educational Resources Information Center

    Li, Andrew Yue-Lin; Carvalho, Helena

    2016-01-01

    Prevalent in 20-57% of stroke patients, visual field defects have been shown to impact quality of life. Studies have shown increased risk of falling, ambulatory difficulties, impaired reading ability, and feelings of panic in crowded or unfamiliar places in patients with visual field defects. Rehabilitation, independence, and mental health may…

  10. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    PubMed Central

    Rowe, Fiona J.; Rowlands, Alison

    2014-01-01

    Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983

  11. Vision-related fitness to drive mobility scooters: A practical driving test.

    PubMed

    Cordes, Christina; Heutink, Joost; Tucha, Oliver M; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M

    2017-03-06

    To investigate practical fitness to drive mobility scooters, comparing visually impaired participants with healthy controls. Between-subjects design. Forty-six visually impaired (13 with very low visual acuity, 10 with low visual acuity, 11 with peripheral field defects, 12 with multiple visual impairment) and 35 normal-sighted controls. Participants completed a practical mobility scooter test-drive, which was recorded on video. Two independent occupational therapists specialized in orientation and mobility evaluated the videos systematically. Approximately 90% of the visually impaired participants passed the driving test. On average, participants with visual impairments performed worse than normal-sighted controls, but were judged sufficiently safe. In particular, difficulties were observed in participants with peripheral visual field defects and those with a combination of low visual acuity and visual field defects. People with visual impairment are, in practice, fit to drive mobility scooters; thus visual impairment on its own should not be viewed as a determinant of safety to drive mobility scooters. However, special attention should be paid to individuals with visual field defects with or without a combined low visual acuity. The use of an individual practical fitness-to-drive test is advised.

  12. Visual field defects of the contralateral eye of non-arteritic ischemic anterior optic neuropathy: are they related to sleep apnea?

    PubMed

    Aptel, Florent; Aryal-Charles, Nischal; Tamisier, Renaud; Pépin, Jean-Louis; Lesoin, Antoine; Chiquet, Christophe

    2017-06-01

    To evaluate whether obstructive sleep apnea (OSA) is responsible for the visual field defects found in the fellow eyes of patients with non-arteritic ischemic optic neuropathy (NAION). Prospective cross-sectional study. The visual fields of the fellow eyes of NAION subjects with OSA were compared to the visual fields of control OSA patients matched for OSA severity. All patients underwent comprehensive ophthalmological and general examination including Humphrey 24.2 SITA-Standard visual field and polysomnography. Visual field defects were classified according the Ischemic Optic Neuropathy Decompression Trial (IONDT) classification. From a cohort of 78 consecutive subjects with NAION, 34 unaffected fellow eyes were compared to 34 control eyes of subjects matched for OSA severity (apnea-hypopnea index [AHI] 35.5 ± 11.6 vs 35.4 ± 9.4 events per hour, respectively, p = 0.63). After adjustment for age and body mass index, all visual field parameters were significantly different between the NAION fellow eyes and those of the control OSA groups, including mean deviation (-4.5 ± 3.7 vs -1.3 ± 1.8 dB, respectively, p < 0.05), visual field index (91.6 ± 10 vs 97.4 ± 3.5%, respectively, p = 0.002), pattern standard deviation (3.7 ± 2.3 vs 2.5 ± 2 dB, respectively, p = 0.015), and number of subjects with at least one defect on the IONDT classification (20 vs 10, respectively, p < 0.05). OSA alone does not explain the visual field defects frequently found in the fellow eyes of NAION patients.

  13. Visual defects and commercial motorcycle accidents in south eastern Nigeria.

    PubMed

    Achigbu, E O; Fiebai, B

    2013-01-01

    Commercial motorcyclists are a regular part of our highways, especially with the decrease in the number and quality of good roads. This study is aimed at determining the role of vision if any in the increasing number of road traffic accidents (RTA's) among commercial motorcyclists in Enugu metropolis, Nigeria. A cross sectional survey with a multi stage random sampling design was used to select the 615 commercial motorcyclists in Enugu metropolis enrolled in the study. Out of the 615 motorcyclists, seven (1.14% +/- 0.70%) motorcyclists had visual impairment (< 6/18-3/60). Visual field defect was noted in 2.3% +/- 0.98% while 2.6% +/- 0.98% had colour vision defect. The prevalence of road traffic accident (RTA) was 57.7%. Visual impairment was not significantly associated with RTA (P = 0.333) while visual field defect (P = 0.000), and colour vision defect (P = 0.003) were positively associated with RTA. Inexperienced riders had significantly more RTAs than their counterparts (P = 0.000). CONCLUSION; Visual field defect, and colour vision defect were significantly associated with RTA but this finding is in the backdrop of poor training, and inexperience which also significantly affected RTA among the predominantly young riders involved in RTA.

  14. Chronic Invasive Fungal Sinusitis Presenting as Inferior Altitudinal Visual Field Defect.

    PubMed

    Bansal, Reema; Takkar, Aastha; Lal, Vivek; Bal, Amanjit; Bansal, Sandeep

    2017-06-01

    A young male with acute blurring of vision (6/9) complained of an inferior altitudinal field defect in right eye. Clinical ophthalmological examination was normal. Magnetic resonance imaging (MRI) of the brain revealed the expansion and mucosal thickening of right posterior ethmoid and sphenoid sinuses and opacified right maxillary sinus. Surgical intervention (transethmoidal sphenoidotomy) and histopathological examination revealed chronic invasive granulomatous fungal sinusitis. Anti-fungal therapy led to resolution of visual complaints and restoration of visual field defects.

  15. Interventions for visual field defects in patients with stroke.

    PubMed

    Pollock, Alex; Hazelton, Christine; Henderson, Clair A; Angilley, Jayne; Dhillon, Baljean; Langhorne, Peter; Livingstone, Katrina; Munro, Frank A; Orr, Heather; Rowe, Fiona J; Shahani, Uma

    2011-10-05

    Visual field defects are estimated to affect 20% to 57% of people who have had a stroke. Visual field defects can affect functional ability in activities of daily living (commonly affecting mobility, reading and driving), quality of life, ability to participate in rehabilitation, and depression, anxiety and social isolation following stroke. There are many interventions for visual field defects, which are proposed to work by restoring the visual field (restitution); compensating for the visual field defect by changing behaviour or activity (compensation); substituting for the visual field defect by using a device or extraneous modification (substitution); or ensuring appropriate diagnosis, referral and treatment prescription through standardised assessment or screening, or both. To determine the effects of interventions for people with visual field defects after stroke. We searched the Cochrane Stroke Group Trials Register (February 2011), the Cochrane Eyes and Vision Group Trials Register (December 2009) and nine electronic bibliographic databases including CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to December 2009), EMBASE (1980 to December 2009), CINAHL (1982 to December 2009), AMED (1985 to December 2009), and PsycINFO (1967 to December 2009). We also searched reference lists and trials registers, handsearched journals and conference proceedings and contacted experts. Randomised trials in adults after stroke, where the intervention was specifically targeted at improving the visual field defect or improving the ability of the participant to cope with the visual field loss. The primary outcome was functional ability in activities of daily living and secondary outcomes included functional ability in extended activities of daily living, reading ability, visual field measures, balance, falls, depression and anxiety, discharge destination or residence after stroke, quality of life and social isolation, visual scanning, adverse events and death. Two review authors independently screened abstracts, extracted data and appraised trials. We undertook an assessment of methodological quality for allocation concealment, blinding of outcome assessors, method of dealing with missing data, and other potential sources of bias. Thirteen studies (344 randomised participants, 285 of whom were participants with stroke) met the inclusion criteria for this review. However, only six of these studies compared the effect of an intervention with a placebo, control or no treatment group and were included in comparisons within this review. Four studies compared the effect of scanning (compensatory) training with a control or placebo intervention. Meta-analysis demonstrated that scanning training is more effective than control or placebo at improving reading ability (three studies, 129 participants; mean difference (MD) 3.24, 95% confidence interval (CI) 0.84 to 5.59) and visual scanning (three studies, 129 participants; MD 18.84, 95% CI 12.01 to 25.66) but that scanning may not improve visual field outcomes (two studies, 110 participants; MD -0.70, 95% CI -2.28 to 0.88). There were insufficient data to enable generalised conclusions to be made about the effectiveness of scanning training relative to control or placebo for the primary outcome of activities of daily living (one study, 33 participants). Only one study (19 participants) compared the effect of a restitutive intervention with a control or placebo intervention and only one study (39 participants) compared the effect of a substitutive intervention with a control or placebo intervention. There is limited evidence which supports the use of compensatory scanning training for patients with visual field defects (and possibly co-existing visual neglect) to improve scanning and reading outcomes. There is insufficient evidence to reach a conclusion about the impact of compensatory scanning training on functional activities of daily living. There is insufficient evidence to reach generalised conclusions about the benefits of visual restitution training (VRT) (restitutive intervention) or prisms (substitutive intervention) for patients with visual field defects after stroke.

  16. Driving with Binocular Visual Field Loss? A Study on a Supervised On-Road Parcours with Simultaneous Eye and Head Tracking

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario. PMID:24523869

  17. The influence of artificial scotomas on eye movements during visual search.

    PubMed

    Cornelissen, Frans W; Bruin, Klaas J; Kooijman, Aart C

    2005-01-01

    Fixation durations are normally adapted to the difficulty of the foveal analysis task. We examine to what extent artificial central and peripheral visual field defects interfere with this adaptation process. Subjects performed a visual search task while their eye movements were registered. The latter were used to drive a real-time gaze-dependent display that was used to create artificial central and peripheral visual field defects. Recorded eye movements were used to determine saccadic amplitude, number of fixations, fixation durations, return saccades, and changes in saccade direction. For central defects, although fixation duration increased with the size of the absolute central scotoma, this increase was too small to keep recognition performance optimal, evident from an associated increase in the rate of return saccades. Providing a relatively small amount of visual information in the central scotoma did substantially reduce subjects' search times but not their fixation durations. Surprisingly, reducing the size of the tunnel also prolonged fixation duration for peripheral defects. This manipulation also decreased the rate of return saccades, suggesting that the fixations were prolonged beyond the duration required by the foveal task. Although we find that adaptation of fixation duration to task difficulty clearly occurs in the presence of artificial scotomas, we also find that such field defects may render the adaptation suboptimal for the task at hand. Thus, visual field defects may not only hinder vision by limiting what the subject sees of the environment but also by limiting the visual system's ability to program efficient eye movements. We speculate this is because of how visual field defects bias the balance between saccade generation and fixation stabilization.

  18. COMPUTERIZED EXPERT SYSTEM FOR EVALUATION OF AUTOMATED VISUAL FIELDS FROM THE ISCHEMIC OPTIC NEUROPATHY DECOMPRESSION TRIAL: METHODS, BASELINE FIELDS, AND SIX-MONTH LONGITUDINAL FOLLOW-UP

    PubMed Central

    Feldon, Steven E

    2004-01-01

    ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764

  19. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  20. Field of dreamers and dreamed-up fields: functional and fake perimetry.

    PubMed

    Thompson, J C; Kosmorsky, G S; Ellis, B D

    1996-01-01

    Hysterical and malingering patients can manifest visual field defects on perimetry (visual field testing), including defects suggestive of true visual pathway pathology. It has been shown that control subjects can easily imitate some pathologic defects with automated, computed perimetry. The authors sought to determine whether subjects could imitate the same pathologic defect with manual and automated perimetry. Six subjects posed as patients with neurologic problems. They had manual perimetry with both an experienced and inexperienced technician followed by automated perimetry. They were later interviewed about the methods of the technicians and the difficulty of the exercise. Four of six subjects easily imitated the assigned defects with both technicians on manual perimetry and with automated perimetry. These included quadrantic, altitudinal, hemianopic, and enlarged blind-spot defects. Two subjects who were assigned cecocentral and paracentral scotomas instead produced enlarged blind spots by manual perimetry and defects suggestive of chiasmal pathology by automated perimetry. Paradoxically, some subjects found that experienced technicians were easier to fool than inexperienced technicians because of the systematic way in which experienced technicians defined defects. With minimal coaching, some subjects can imitate visual fields with enlarged blind spots, quadrantic, hemianopic, and altitudinal defects with ease and reproducibility by both automated and manual perimetry. Cecocentral and paracentral scotomas are harder to imitate but may be mistaken as representing chiasmal pathology. Paradoxically, experienced technicians may not be better at detecting hysterical or malingering individuals.

  1. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma.

    PubMed

    Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos

    2009-01-01

    To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 +/- 0.6 years). Color vision defects were studied using a special computer program for Farnsworth-Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30-2. Both tests were repeated every six months. In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 +/- 31.79) and OH eyes (75.51 +/- 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was -20.62 +/- 2.75 (t value 9.08, p < 0.001) while in OH eyes was -2.11 +/- 4.36 (t value 1.1, p = 0.276). Pearson's coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields.

  2. Visual field defects after missile injuries to the geniculo-striate pathway in man.

    NASA Technical Reports Server (NTRS)

    Koerner, F.; Teuber, H.-L.

    1973-01-01

    The main objective of the survey reported was a quantitative comparison of different visual functions at identical retinal points of individual patients. The possibility to develop objective forms of visual-field testing was also explored, taking into account reports by Frydrychowicz and Harms (1940) and Harms (1951). These investigators had insisted that pupillary responses to light are depressed in areas of homonymous scotomata. The shapes of homonymous visual field defects are discussed together with questions regarding the association and dissociation of symptoms.

  3. A randomized controlled trial comparing 2 interventions for visual field loss with standard occupational therapy during inpatient stroke rehabilitation.

    PubMed

    Mödden, Claudia; Behrens, Marion; Damke, Iris; Eilers, Norbert; Kastrup, Andreas; Hildebrandt, Helmut

    2012-06-01

    Compensatory and restorative treatments have been developed to improve visual field defects after stroke. However, no controlled trials have compared these interventions with standard occupational therapy (OT). A total of 45 stroke participants with visual field defect admitted for inpatient rehabilitation were randomized to restorative computerized training (RT) using computer-based stimulation of border areas of their visual field defects or to a computer-based compensatory therapy (CT) teaching a visual search strategy. OT, in which different compensation strategies were used to train for activities of daily living, served as standard treatment for the active control group. Each treatment group received 15 single sessions of 30 minutes distributed over 3 weeks. The primary outcome measures were visual field expansion for RT, visual search performance for CT, and reading performance for both treatments. Visual conjunction search, alertness, and the Barthel Index were secondary outcomes. Compared with OT, CT resulted in a better visual search performance, and RT did not result in a larger expansion of the visual field. Intragroup pre-post comparisons demonstrated that CT improved all defined outcome parameters and RT several, whereas OT only improved one. CT improved functional deficits after visual field loss compared with standard OT and may be the intervention of choice during inpatient rehabilitation. A larger trial that includes lesion location in the analysis is recommended.

  4. Research on metallic material defect detection based on bionic sensing of human visual properties

    NASA Astrophysics Data System (ADS)

    Zhang, Pei Jiang; Cheng, Tao

    2018-05-01

    Due to the fact that human visual system can quickly lock the areas of interest in complex natural environment and focus on it, this paper proposes an eye-based visual attention mechanism by simulating human visual imaging features based on human visual attention mechanism Bionic Sensing Visual Inspection Model Method to Detect Defects of Metallic Materials in the Mechanical Field. First of all, according to the biologically visually significant low-level features, the mark of defect experience marking is used as the intermediate feature of simulated visual perception. Afterwards, SVM method was used to train the advanced features of visual defects of metal material. According to the weight of each party, the biometrics detection model of metal material defect, which simulates human visual characteristics, is obtained.

  5. Scene and human face recognition in the central vision of patients with glaucoma

    PubMed Central

    Aptel, Florent; Attye, Arnaud; Guyader, Nathalie; Boucart, Muriel; Chiquet, Christophe; Peyrin, Carole

    2018-01-01

    Primary open-angle glaucoma (POAG) firstly mainly affects peripheral vision. Current behavioral studies support the idea that visual defects of patients with POAG extend into parts of the central visual field classified as normal by static automated perimetry analysis. This is particularly true for visual tasks involving processes of a higher level than mere detection. The purpose of this study was to assess visual abilities of POAG patients in central vision. Patients were assigned to two groups following a visual field examination (Humphrey 24–2 SITA-Standard test). Patients with both peripheral and central defects and patients with peripheral but no central defect, as well as age-matched controls, participated in the experiment. All participants had to perform two visual tasks where low-contrast stimuli were presented in the central 6° of the visual field. A categorization task of scene images and human face images assessed high-level visual recognition abilities. In contrast, a detection task using the same stimuli assessed low-level visual function. The difference in performance between detection and categorization revealed the cost of high-level visual processing. Compared to controls, patients with a central visual defect showed a deficit in both detection and categorization of all low-contrast images. This is consistent with the abnormal retinal sensitivity as assessed by perimetry. However, the deficit was greater for categorization than detection. Patients without a central defect showed similar performances to the controls concerning the detection and categorization of faces. However, while the detection of scene images was well-maintained, these patients showed a deficit in their categorization. This suggests that the simple loss of peripheral vision could be detrimental to scene recognition, even when the information is displayed in central vision. This study revealed subtle defects in the central visual field of POAG patients that cannot be predicted by static automated perimetry assessment using Humphrey 24–2 SITA-Standard test. PMID:29481572

  6. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma

    PubMed Central

    Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos

    2009-01-01

    Purpose: To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. Methods: In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 ± 0.6 years). Color vision defects were studied using a special computer program for Farnsworth–Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30–2. Both tests were repeated every six months. Results: In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 ± 31.79) and OH eyes (75.51 ± 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was −20.62 ± 2.75 (t value 9.08, p < 0.001) while in OH eyes was −2.11 ± 4.36 (t value 1.1, p = 0.276). Pearson’s coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Conclusion: Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields. PMID:19668575

  7. Detection of Visual Field Loss in Pituitary Disease: Peripheral Kinetic Versus Central Static

    PubMed Central

    Rowe, Fiona J.; Cheyne, Christopher P.; García-Fiñana, Marta; Noonan, Carmel P.; Howard, Claire; Smith, Jayne; Adeoye, Joanne

    2015-01-01

    Abstract Visual field assessment is an important clinical evaluation for eye disease and neurological injury. We evaluated Octopus semi-automated kinetic peripheral perimetry (SKP) and Humphrey static automated central perimetry for detection of neurological visual field loss in patients with pituitary disease. We carried out a prospective cross-sectional diagnostic accuracy study comparing Humphrey central 30-2 SITA threshold programme with a screening protocol for SKP on Octopus perimetry. Humphrey 24-2 data were extracted from 30-2 results. Results were independently graded for presence/absence of field defect plus severity of defect. Fifty patients (100 eyes) were recruited (25 males and 25 females), with mean age of 52.4 years (SD = 15.7). Order of perimeter assessment (Humphrey/Octopus first) and order of eye tested (right/left first) were randomised. The 30-2 programme detected visual field loss in 85%, the 24-2 programme in 80%, and the Octopus combined kinetic/static strategy in 100% of eyes. Peripheral visual field loss was missed by central threshold assessment. Qualitative comparison of type of visual field defect demonstrated a match between Humphrey and Octopus results in 58%, with a match for severity of defect in 50%. Tests duration was 9.34 minutes (SD = 2.02) for Humphrey 30-2 versus 10.79 minutes (SD = 4.06) for Octopus perimetry. Octopus semi-automated kinetic perimetry was found to be superior to central static testing for detection of pituitary disease-related visual field loss. Where reliant on Humphrey central static perimetry, the 30-2 programme is recommended over the 24-2 programme. Where kinetic perimetry is available, this is preferable to central static programmes for increased detection of peripheral visual field loss. PMID:27928344

  8. The effect of simulated altitude on the visual fields of glaucoma patients and the elderly.

    DOT National Transportation Integrated Search

    1991-01-01

    This study tests whether mild hypoxia, that is typically encountered in civilian aircraft, causes temporary visual field defects in elderly persons or temporarily increases pre-existing defects in persons with glaucoma. The central 24-2 program on th...

  9. The ability of healthy volunteers to simulate a neurologic field defect on automated perimetry.

    PubMed

    Ghate, Deepta; Bodnarchuk, Brian; Sanders, Sheila; Deokule, Sunil; Kedar, Sachin

    2014-03-01

    To determine if volunteers can simulate and reproduce 3 types of neurologic field defects: hemianopia, quadrantanopia, and central scotoma. Cross-sectional study. Thirty healthy volunteers new to perimetry (including automated perimetry). After informed consent, volunteers were randomized to 1 of the 3 visual field defects listed above. All visual field testing was performed on the right eye using the Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA) SITA Fast 24-2 protocol. Each volunteer was provided with standard new patient instructions and was shown a diagram of the defect to be simulated. Two sets of visual fields were performed on the right eye with 10 minutes between tests. Three experts used the Ocular Hypertension Treatment Study reading center criteria and determined if the simulation was successful. Proportion of volunteers able to simulate the assigned visual field. All 10 volunteers (100%) successfully simulated a hemianopia on the first and second fields. All 10 volunteers (100%) simulated a quadrantanopia on the first field and 9 (90%) did so on the second field. Eight volunteers (80%) successfully simulated a central scotoma in the first field and all 10 (100%) did so on in the second field. Reliability criteria were excellent. Forty-seven fields (78%) had 0 fixation losses, 48 (80%) had 0 false-positive results, and 44 (73%) had 0 false-negative results. It is easy to simulate reproducible and reliable neurologic field defects on automated perimetry using HFA. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. [Are Visual Field Defects Reversible? - Visual Rehabilitation with Brains].

    PubMed

    Sabel, B A

    2017-02-01

    Visual field defects are considered irreversible because the retina and optic nerve do not regenerate. Nevertheless, there is some potential for recovery of the visual fields. This can be accomplished by the brain, which analyses and interprets visual information and is able to amplify residual signals through neuroplasticity. Neuroplasticity refers to the ability of the brain to change its own functional architecture by modulating synaptic efficacy. This is actually the neurobiological basis of normal learning. Plasticity is maintained throughout life and can be induced by repetitively stimulating (training) brain circuits. The question now arises as to how plasticity can be utilised to activate residual vision for the treatment of visual field loss. Just as in neurorehabilitation, visual field defects can be modulated by post-lesion plasticity to improve vision in glaucoma, diabetic retinopathy or optic neuropathy. Because almost all patients have some residual vision, the goal is to strengthen residual capacities by enhancing synaptic efficacy. New treatment paradigms have been tested in clinical studies, including vision restoration training and non-invasive alternating current stimulation. While vision training is a behavioural task to selectively stimulate "relative defects" with daily vision exercises for the duration of 6 months, treatment with alternating current stimulation (30 min. daily for 10 days) activates and synchronises the entire retina and brain. Though full restoration of vision is not possible, such treatments improve vision, both subjectively and objectively. This includes visual field enlargements, improved acuity and reaction time, improved orientation and vision related quality of life. About 70 % of the patients respond to the therapies and there are no serious adverse events. Physiological studies of the effect of alternating current stimulation using EEG and fMRI reveal massive local and global changes in the brain. These include local activation of the visual cortex and global reorganisation of neuronal brain networks. Because modulation of neuroplasticity can strengthen residual vision, the brain deserves a better reputation in ophthalmology for its role in visual rehabilitation. For patients, there is now more light at the end of the tunnel, because vision loss in some areas of the visual field defect is indeed reversible. Georg Thieme Verlag KG Stuttgart · New York.

  11. Early detection of glaucoma by means of a novel 3D computer‐automated visual field test

    PubMed Central

    Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald

    2007-01-01

    Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma. PMID:17504855

  12. Intraoperative Subcortical Electrical Mapping of the Optic Tract in Awake Surgery Using a Virtual Reality Headset.

    PubMed

    Mazerand, Edouard; Le Renard, Marc; Hue, Sophie; Lemée, Jean-Michel; Klinger, Evelyne; Menei, Philippe

    2017-01-01

    Brain mapping during awake craniotomy is a well-known technique to preserve neurological functions, especially the language. It is still challenging to map the optic radiations due to the difficulty to test the visual field intraoperatively. To assess the visual field during awake craniotomy, we developed the Functions' Explorer based on a virtual reality headset (FEX-VRH). The impaired visual field of 10 patients was tested with automated perimetry (the gold standard examination) and the FEX-VRH. The proof-of-concept test was done during the surgery performed on a patient who was blind in his right eye and presenting with a left parietotemporal glioblastoma. The FEX-VRH was used intraoperatively, simultaneously with direct subcortical electrostimulation, allowing identification and preservation of the optic radiations. The FEX-VRH detected 9 of the 10 visual field defects found by automated perimetry. The patient who underwent an awake craniotomy with intraoperative mapping of the optic tract using the FEX-VRH had no permanent postoperative visual field defect. Intraoperative visual field assessment with the FEX-VRH during direct subcortical electrostimulation is a promising approach to mapping the optical radiations and preventing a permanent visual field defect during awake surgery for epilepsy or tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  14. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  15. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  16. Visual Field Defects and Retinal Ganglion Cell Losses in Human Glaucoma Patients

    PubMed Central

    Harwerth, Ronald S.; Quigley, Harry A.

    2007-01-01

    Objective The depth of visual field defects are correlated with retinal ganglion cell densities in experimental glaucoma. This study was to determine whether a similar structure-function relationship holds for human glaucoma. Methods The study was based on retinal ganglion cell densities and visual thresholds of patients with documented glaucoma (Kerrigan-Baumrind, et al.) The data were analyzed by a model that predicted ganglion cell densities from standard clinical perimetry, which were then compared to histologic cell counts. Results The model, without free parameters, produced accurate and relatively precise quantification of ganglion cell densities associated with visual field defects. For 437 sets of data, the unity correlation for predicted vs. measured cell densities had a coefficient of determination of 0.39. The mean absolute deviation of the predicted vs. measured values was 2.59 dB, the mean and SD of the distribution of residual errors of prediction was -0.26 ± 3.22 dB. Conclusions Visual field defects by standard clinical perimetry are proportional to neural losses caused by glaucoma. Clinical Relevance The evidence for quantitative structure-function relationships provides a scientific basis of interpreting glaucomatous neuropathy from visual thresholds and supports the application of standard perimetry to establish the stage of the disease. PMID:16769839

  17. Patterned Video Sensors For Low Vision

    NASA Technical Reports Server (NTRS)

    Juday, Richard D.

    1996-01-01

    Miniature video cameras containing photoreceptors arranged in prescribed non-Cartesian patterns to compensate partly for some visual defects proposed. Cameras, accompanied by (and possibly integrated with) miniature head-mounted video display units restore some visual function in humans whose visual fields reduced by defects like retinitis pigmentosa.

  18. The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators.

    PubMed

    2000-10-01

    To investigate the association between control of intraocular pressure after surgical intervention for glaucoma and visual field deterioration. In the Advanced Glaucoma Intervention Study, eyes were randomly assigned to one of two sequences of glaucoma surgery, one beginning with argon laser trabeculoplasty and the other trabeculectomy. In the present article we examine the relationship between intraocular pressure and progression of visual field damage over 6 or more years of follow-up. In the first analysis, designated Predictive Analysis, we categorize 738 eyes into three groups based on intraocular pressure determinations over the first three 6-month follow-up visits. In the second analysis, designated Associative Analysis, we categorize 586 eyes into four groups based on the percent of 6-month visits over the first 6 follow-up years in which eyes presented with intraocular pressure less than 18 mm Hg. The outcome measure in both analyses is change from baseline in follow-up visual field defect score (range, 0 to 20 units). In the Predictive Analysis, eyes with early average intraocular pressure greater than 17.5 mm Hg had an estimated worsening during subsequent follow-up that was 1 unit of visual field defect score greater than eyes with average intraocular pressure less than 14 mm Hg (P =.002). This amount of worsening was greater at 7 years (1.89 units; P <.001) than at 2 years (0.64 units; P =.071). In the Associative Analysis, eyes with 100% of visits with intraocular pressure less than 18 mm Hg over 6 years had mean changes from baseline in visual field defect score close to zero during follow-up, whereas eyes with less than 50% of visits with intraocular pressure less than 18 mm Hg had an estimated worsening over follow-up of 0.63 units of visual field defect score (P =.083). This amount of worsening was greater at 7 years (1.93 units; P <.001) than at 2 years (0.25 units; P =.572). In both analyses low intraocular pressure is associated with reduced progression of visual field defect, supporting evidence from earlier studies of a protective role for low intraocular pressure in visual field deterioration.

  19. Neurorehabilitation of saccadic ocular movement in a patient with a homonymous hemianopia postgeniculate caused by an arteriovenous malformation

    PubMed Central

    Pineda-Ortíz, Mirna; Pacheco-López, Gustavo; Rubio-Osornio, Moisés; Rubio, Carmen; Valadez-Rodríguez, Juan

    2018-01-01

    Abstract Rationale: Visual therapy, which includes a restorative and compensatory approach, seems to be a viable treatment option for homonymous defects of the visual field in patients with postgeniculate injury of the visual pathway, due to occipital arteriovenous malformation (AVM). Until now, the Mexican population suffering from homonymous hemianopia did not have health services that provided any type of visual therapy for their condition. Patient concerns: A 31-year-old patient, who underwent a surgical procedure for resection of the AVM, was referred with posterior low vision on the left side. Diagnoses: The patient was diagnosed with left homonymous hemianopia. Interventions: Visual neurorehabilitation therapy (NRT), which integrated restorative and compensatory approaches, was administered for 3 hours each week. NRT included fixation, follow-up, search, peripheral vision, and reading. Outcomes: The NRT did not change visual field defects and, retinotopocally, the same campimetric defects remained. However, after training the tracking ocular movements improved to standard values on the ENG, further, the visual search became more organized. The reading reached a level without mistakes, with rhythm and goog intonation. The Beck test demostrated an improvement in depression symptoms. Regarding the daily life activities, the patient reported significant improvements. Lessons: Visual NRT can significantly improve eye movements, as well as the quality of life and independence of the patient. This integral approach could be an effective therapeutic option for homonymous defects of the visual field. PMID:29538218

  20. [Visual field defect in a patient given sodium valporate then carbamazepine: possible effect of aminotransferase inhibition].

    PubMed

    Jung, Ph; Doussard-Lefaucheux, S

    2002-04-01

    We report the case of a 25-years old woman with anti-epileptic drugs who presents a visual field defect similar to those described with vigabatrin even though she was successfully treated with valproic acid then carbamazepine without vigabatrin. The association with trichorrhexis nodosa, a hair disease sometimes associated with inherited perturbation of metabolism of urea cycle in which visual loss can occur, could suggest an aspecific inhibition of several aminotransferases which could explain different adverse effects of some anti-epileptic drugs (visual abnormalities, alopecia) perhaps in genetic predisposed patients.

  1. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    PubMed

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  2. Accelerated defect visualization of microelectronic systems using binary search with fixed pitch-catch distance laser ultrasonic scanning

    NASA Astrophysics Data System (ADS)

    Park, Byeongjin; Sohn, Hoon

    2018-04-01

    The practicality of laser ultrasonic scanning is limited because scanning at a high spatial resolution demands a prohibitively long scanning time. Inspired by binary search, an accelerated defect visualization technique is developed to visualize defect with a reduced scanning time. The pitch-catch distance between the excitation point and the sensing point is also fixed during scanning to maintain a high signal-to-noise ratio of measured ultrasonic responses. The approximate defect boundary is identified by examining the interactions between ultrasonic waves and defect observed at the scanning points that are sparsely selected by a binary search algorithm. Here, a time-domain laser ultrasonic response is transformed into a spatial ultrasonic domain response using a basis pursuit approach so that the interactions between ultrasonic waves and defect can be better identified in the spatial ultrasonic domain. Then, the area inside the identified defect boundary is visualized as defect. The performance of the proposed defect visualization technique is validated through an experiment on a semiconductor chip. The proposed defect visualization technique accelerates the defect visualization process in three aspects: (1) The number of measurements that is necessary for defect visualization is dramatically reduced by a binary search algorithm; (2) The number of averaging that is necessary to achieve a high signal-to-noise ratio is reduced by maintaining the wave propagation distance short; and (3) With the proposed technique, defect can be identified with a lower spatial resolution than the spatial resolution required by full-field wave propagation imaging.

  3. Corticosteroid therapy in patients with non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Vidović, Tomislav; Cerovski, Branimir; Perić, Sanja; Kordić, Rajko; Mrazovac, Danijela

    2015-03-01

    Non-arteritic anterior ischemic optic neuropathy is one of the most common conditions affecting the optic nerve in the elderly. It may lead to severe visual loss. Typical symptoms are painless impairment of visual function accompanied by relative afferent pupillary defect, edema of the optic disc and visual field defects. Aim is to present 38 patients with nonarteritic anterior ischemic optic neuropathy who were treated with corticosteroid therapy. This prospective study involved 38 patients, 20 men and 18 women aged 60-75 years who were treated with corticosteroid therapy. The study included patients with visual acuity in the affected eye from 0.1 to 0.8 according to Snellen. Every patient underwent clinical examination, the Octopus 900 perimetry in G program, laboratory testing, while the compressive optic neuropathy was rule out with MSCT of the brain and orbits. The most common forms of visual field defect are altitudinal defect and diffuse depression. Corticosteroid therapy led to recovery in 65% of patient, in 30% of patients did not change, while the deterioration occurred in 5% of patients.

  4. [Atypical optic neuritis in systemic lupus erythematosus (SLE)].

    PubMed

    Eckstein, A; Kötter, I; Wilhelm, H

    1995-11-01

    A 67-year-old woman experienced acute unilateral visual loss accompanied by pain with eye movements. There was a marked relative afferent pupillary defect and a nerve fiber bundle defect in the upper half of the visual field. Optic discs were normal. After 4 days vision worsened to motion detection and only a temporal island was left in the visual field. The optic disc margin was blurred. Since thirty years she had been suffering from renal insufficiency. Immunoserologic examination revealed elevated ANA and DS-DNA antibody titers. An optic neuritis in systemic lupus erythematosus was diagnosed, which is called atopic, because of its association to a systemic disease and the old age of the patient. The patient was treated with 100 mg prednisolone/day, slowly tapered. Within 6 weeks visual acuity improved to 0.6 and visual field normalized except for a small nerve fiber bundle defect. Autoimmune optic neuritis often responds to treatment with corticosteroids. Early onset of treatment is important. Immunopathologic examinations are an important diagnostic tool in atopic optic neuritis. Their results may even have consequences for the treatment of the underlying disease.

  5. Improved detection following Neuro-Eye Therapy in patients with post-geniculate brain damage.

    PubMed

    Sahraie, Arash; Macleod, Mary-Joan; Trevethan, Ceri T; Robson, Siân E; Olson, John A; Callaghan, Paula; Yip, Brigitte

    2010-09-01

    Damage to the optic radiation or the occipital cortex results in loss of vision in the contralateral visual field, termed partial cortical blindness or hemianopia. Previously, we have demonstrated that stimulation in the field defect using visual stimuli with optimal properties for blindsight detection can lead to increases in visual sensitivity within the blind field of a group of patients. The present study was aimed to extend the previous work by investigating the effect of positive feedback on recovery of visual sensitivity. Patients' abilities for detection of a range of spatial frequencies within their field defect were determined using a temporal two-alternative forced-choice technique, before and after a period of visual training (n = 4). Patients underwent Neuro-Eye Therapy which involved detection of temporally modulated spatial grating patches at specific retinal locations within their field defect. Three patients showed improved detection ability following visual training. Based on our previous studies, we had hypothesised that should the occipital brain lesion extend anteriorly to the thalamus, little recovery would be expected. Here, we describe one such case who showed no improvements after extensive training. The present study provides further evidence that recovery (a) can be gradual and may require a large number of training sessions (b) can be accelerated using positive feedback and (c) may be less likely to take place if the occipital damage extends anteriorly to the thalamus.

  6. Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential objective perimetry for the diagnosis and early detection of glaucomatous field defects.

    PubMed

    Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari

    2014-02-01

    Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.

  7. Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

    PubMed Central

    Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima

    2014-01-01

    Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212

  8. Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma

    PubMed Central

    Murata, Noriaki; Fukuchi, Takeo

    2017-01-01

    Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478

  9. Construction Productivity Advancement Research (CPAR) Program: Improved Materials and Processes for Sealing and Resealing Joints in Portland Cement Concrete Pavements - Field Evaluation

    DTIC Science & Technology

    1993-10-01

    sealant was determined by noting the type and number of defects each sealant incurred. Figure 4 provides a sample evaluation sheet used dur- ing the field...was conducted by visually inspect- ing the mater~al for defects . If any defects were noted, the type of defect was described and the quant~ty of that... defect was measured. The quantity of the defect was dividted by the total quantity of sealant and the result reported as percent defect . Adhesion and

  10. Comparison of Threshold Saccadic Vector Optokinetic Perimetry (SVOP) and Standard Automated Perimetry (SAP) in Glaucoma. Part II: Patterns of Visual Field Loss and Acceptability.

    PubMed

    McTrusty, Alice D; Cameron, Lorraine A; Perperidis, Antonios; Brash, Harry M; Tatham, Andrew J; Agarwal, Pankaj K; Murray, Ian C; Fleck, Brian W; Minns, Robert A

    2017-09-01

    We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.

  11. Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

    PubMed Central

    Rowe, Fiona J.; Noonan, Carmel; Manuel, Melanie

    2013-01-01

    Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Results. 64 patients (113 eyes) underwent dual perimetry assessment. Mean duration of assessment for SKP was 4.54 minutes ±0.18 and 6.17 ± 0.12 for FF120 (P = 0.0001). 80% of results were correctly matched for normal or abnormal visual fields using the I4e target versus FF120, and 73.5% were correctly matched using the I2e target versus FF120. When comparing Octopus results with combined I4e and I2e isopters to the FF120 result, a match for normal or abnormal fields was recorded in 87%. Conclusions. Humphrey perimetry test duration was generally longer than Octopus SKP. In the absence of kinetic perimetry, peripheral static suprathreshold programme options such as FF120 may be useful for detection of visual field defects. However, statokinetic dissociation may occur. Octopus SKP utilising both I4e and I2e targets provides detailed information of both the defect depth and size and may provide a more representative view of the actual visual field defect. PMID:24558605

  12. Visualization and automatic detection of defect distribution in GaN atomic structure from sampling Moiré phase.

    PubMed

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Kodera, Masako; Suguro, Kyoichi; Miyashita, Naoto

    2017-09-19

    Quantitative detection of defects in atomic structures is of great significance to evaluating product quality and exploring quality improvement process. In this study, a Fourier transform filtered sampling Moire technique was proposed to visualize and detect defects in atomic arrays in a large field of view. Defect distributions, defect numbers and defect densities could be visually and quantitatively determined from a single atomic structure image at low cost. The effectiveness of the proposed technique was verified from numerical simulations. As an application, the dislocation distributions in a GaN/AlGaN atomic structure in two directions were magnified and displayed in Moire phase maps, and defect locations and densities were detected automatically. The proposed technique is able to provide valuable references to material scientists and engineers by checking the effect of various treatments for defect reduction. © 2017 IOP Publishing Ltd.

  13. Binasal hemianopia.

    PubMed

    Salinas-Garcia, R F; Smith, J L

    1978-09-01

    The visual fields of 100 patients referred for neuro-ophthalmologic examination were reviewed; eight cases had binasal visual field defects. Most clinicians have suspected an intracranial cause for such field defects since the classic report of Cushing and Walker in 1912. However, in this study, the cause for the binasal hemianopia was found to be ischemic optic neuropathy in two patients, and one case each of optic nerve drusen, glaucoma, congenital optic nerve pits, and retinitis pigmentosa sine pigmento. Thus 75% of the cases had an intraocular cause for the binasal hemianopia. Two patients had congenital hydrocephalus, and an intracranial basis was thus noted in 25% of these cases. The neurosurgeon should realize that the patient with binasal field defects is much more likely to have an ocular cause than an intracranial one for his problem.

  14. Comparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma.

    PubMed

    Doozandeh, Azadeh; Irandoost, Farnoosh; Mirzajani, Ali; Yazdani, Shahin; Pakravan, Mohammad; Esfandiari, Hamed

    2017-01-01

    This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of defects on pattern deviation (PD) plots were determined. Agreement between two sets regarding the stage of visual field damage was assessed. Pearson's correlation, intra-cluster comparison, paired t-test, and 95% limit of agreement were calculated. Although there was no significant difference between global indices, the agreement between the two devices regarding the global indices was weak (the limit of agreement for mean deviation was -6.08 to 6.08 and that for pattern standard deviation was -4.42 to 3.42). The agreement between SITA-SAP and Matrix-FDT regarding the Glaucoma Hemifield Test (GHT) and the number of defective points in each quadrant and staging of the visual field damage was also weak. Because the correlation between SITA-SAP and Matrix-FDT regarding global indices, GHT, number of defective points, and stage of the visual field damage in mild glaucoma is weak, Matrix-FDT cannot be used interchangeably with SITA-SAP in the early stages of glaucoma.

  15. Nondestructive optical testing of the materials surface structure based on liquid crystals

    NASA Astrophysics Data System (ADS)

    Tomilin, M. G.; Stafeev, S. K.

    2011-08-01

    Thin layers of nematic liquid crystals (NLCs) may be used as recording media for visualizing structural and microrelief defects, distribution of low power physical fields and modifications of the surface. NLCs are more sensitive in comparison with cholesteric and smectic LCs having super molecular structures. The detecting properties of NLCs are based on local layers deformation, induced by surface fields and observed in polarizing microscope. The structural surface defects or physical field's distribution are dramatically change the distribution of surface tension. Surface defects recording becomes possible if NLC deformed structure is illuminated in transparent or reflective modes and observed in optical polarizing microscope and appearing image is compared with background structure. In this case one observes not the real defect but the local deformation in NLCs. The theory was developed to find out the real size of defects. The resolution of NLC layer is more than 2000 lines/mm. The fields of NLC application are solid crystals symmetry, minerals, metals, semiconductors, polymers and glasses structure inhomogeneities and optical coatings defects detecting. The efficiency of NLC method in biophotonics is illustrated by objective detecting cancer tissues character and visualizing the interaction traces of grippe viruses with antibodies. NLCs may detect solvent components structure in tea, wine and perfume giving unique information of their structure. It presents diagnostic information alternative to dyes and fluorescence methods. For the first time the structures of some juices and beverages are visualized to illustrate the unique possibilities of NLCs.

  16. Vision restoration through extrastriate stimulation in patients with visual field defects: a double-blind and randomized experimental study.

    PubMed

    Jobke, Sandra; Kasten, Erich; Sabel, Bernhard A

    2009-01-01

    . Vision restoration therapy (VRT) to treat visual field defects used single-point visual stimulation in areas of residual vision up to now. The question arises if the efficiency of restoration can be increased when the entire region of blindness is trained by a visual stimulus aimed at activating extrastriate pathways (extrastriate VRT). . In this crossover study, 18 patients with visual field defects with prior VRT experience were treated with 2 training paradigms. Group 1 (n = 8) first used extrastriate VRT followed by conventional standard VRT. Group 2 (n = 10) trained in reverse order. Visual field size was assessed with computer-based perimetry and subjective vision with the National Eye Institute Visual Function Questionnaire (NEI-VFQ). . In group 1, stimulus detection in high-resolution perimetry (HRP) improved by 5.9% (P < .01) after extrastriate VRT. After the second training period (standard VRT), detection further improved by 1.8% (P = .093). In group 2, detection performance improved after standard VRT by 2.9% (P < .05) and after extrastriate VRT by 2.9% (P < .05). Detection performance increased twice as much after extrastriate VRT (4.2%) than after standard VRT (2.4%; P < .05). All changes in fixation performance were unrelated to detection improvements. NEI-VFQ did not show any significant changes. . Greater improvement after extrastriate VRT is interpreted as an activation of extrastriate pathways by massive "spiral-like" stimulation. These pathways bypass the damaged visual cortex, stimulating extrastriate cortical regions, and are thought to be involved in blindsight.

  17. Ocular findings in MELAS syndrome – a case report.

    PubMed

    Modrzejewska, Monika; Chrzanowska, Martyna; Modrzejewska, Anna; Romanowska, Hanna; Ostrowska, Iwona; Giżewska, Maria

    We present a case of a child with MELAS syndrome (mitochondrial encephalo-myopathy with lactic acidosis and stroke-like episodes), discussing clinical manifestation, ocular findings and diagnostic challenges. Predominant ocular symptom was a transient complete visual loss, while the predominant ocular sign was a visual field defect. The diagnosia was based on clinical manifestation, laboratory tests, brain scans and genetic testing which confirmed the pathognomonic mutation in the MTTL1 gene encoding the mitochondrial tRNA for leucine 3243> G. Ocular examination demonstrated decreased visual acuity (with bilateral best corrected visual acuity of .1). Periodical, transient visual loss and visual field defects were clinically predominant. Specialist investigations were carried out, which demonstrated homonymous hemianopia (kinetic perimetry), bilateral partial optic nerve atrophy (RetCam). Funduscopy and electrophysiology mfERG study did not confirm features of retinitis pigmentosa. The brain scans revealed numerous small cortical ischemic lesions within the frontal, parietal and temporal lobes, post-stroke focal areas within the occipital lobes and diffuse calcifications of the basal ganglia. During several years of follow-up, visual field defects showed progressive concentric narrowing. The patient received a long-term treatment with arginine, coenzyme Q and vitamin D, both oral and intravenous, but no beneficial effect for the improvement of ophthalmic condition was observed. As it is the case in severe MELAS syndrome, the course of disease was fatal and the patientdied at the age of 14.

  18. Optic nerve dysfunction during gravity inversion. Visual field abnormalities.

    PubMed

    Sanborn, G E; Friberg, T R; Allen, R

    1987-06-01

    Inversion in a head-down position (gravity inversion) results in an intraocular pressure of 35 to 40 mm Hg in normal subjects. We used computerized static perimetry to measure the visual fields of normal subjects during gravity inversion. There were no visual field changes in the central 6 degrees of the visual field compared with the baseline (preinversion) values. However, when the central 30 degrees of the visual field was tested, reversible visual field defects were found in 11 of 19 eyes. We believe that the substantial elevation of intraocular pressure during gravity inversion may pose potential risks to the eyes, and we recommend that inversion for extended periods of time be avoided.

  19. Puberty as a risk factor for less favorable visual outcome in idiopathic intracranial hypertension.

    PubMed

    Stiebel-Kalish, Hadas; Kalish, Yuval; Lusky, Moshe; Gaton, Dan D; Ehrlich, Rita; Shuper, Avinoam

    2006-08-01

    To test the hypothesis that puberty is a risk factor for poorer visual outcome in idiopathic intracranial hypertension (IIH). Retrospective chart review case series. Tertiary referral center, neuro-ophthalmology unit. Ninety-six patients with IIH followed for a minimum of one year. Age (grouped into prepubertal, pubertal, teenage, or adult), obesity, initial intracranial pressure (ICP), measurements and presence of hypertension, anemia, or renal failure were correlated with final visual outcome using chi(2), stepwise logistic regression, and model-selection log linear analyses. Visual outcome was graded into "excellent" -- no evidence of an optic neuropathy or any permanent visual field defect in either eye, "moderate"-- evidence of an optic neuropathy and/or a mild (nasal constriction) visual field defect, or "poor outcome" (peripheral constriction) -- permanent visual field defect. Outcome data were complete for 96 patients. Moderate to poor visual outcome, as opposed to excellent, was significantly associated with puberty (P = .007 using the gender-specific definition of puberty, .0002 using the broad definition). Moderate-poor visual outcome occurred in none of seven IIH patients of prepubertal age (<9 years), in 15 of 26 patients presenting between nine to 16 years, in two of six patients aged 17 to 22 years, and in seven of 57 adult patients over the age of 23 years. In this series of 96 patients with IIH, visual outcome was less favorable in pubertal patients than in prepubertal, teenage, and adult patients. We recommend that clinicians maintain a high index of awareness when caring for pubescent children with IIH.

  20. Multisampling suprathreshold perimetry: a comparison with conventional suprathreshold and full-threshold strategies by computer simulation.

    PubMed

    Artes, Paul H; Henson, David B; Harper, Robert; McLeod, David

    2003-06-01

    To compare a multisampling suprathreshold strategy with conventional suprathreshold and full-threshold strategies in detecting localized visual field defects and in quantifying the area of loss. Probability theory was applied to examine various suprathreshold pass criteria (i.e., the number of stimuli that have to be seen for a test location to be classified as normal). A suprathreshold strategy that requires three seen or three missed stimuli per test location (multisampling suprathreshold) was selected for further investigation. Simulation was used to determine how the multisampling suprathreshold, conventional suprathreshold, and full-threshold strategies detect localized field loss. To determine the systematic error and variability in estimates of loss area, artificial fields were generated with clustered defects (0-25 field locations with 8- and 16-dB loss) and, for each condition, the number of test locations classified as defective (suprathreshold strategies) and with pattern deviation probability less than 5% (full-threshold strategy), was derived from 1000 simulated test results. The full-threshold and multisampling suprathreshold strategies had similar sensitivity to field loss. Both detected defects earlier than the conventional suprathreshold strategy. The pattern deviation probability analyses of full-threshold results underestimated the area of field loss. The conventional suprathreshold perimetry also underestimated the defect area. With multisampling suprathreshold perimetry, the estimates of defect area were less variable and exhibited lower systematic error. Multisampling suprathreshold paradigms may be a powerful alternative to other strategies of visual field testing. Clinical trials are needed to verify these findings.

  1. Collision avoidance in persons with homonymous visual field defects under virtual reality conditions.

    PubMed

    Papageorgiou, Eleni; Hardiess, Gregor; Ackermann, Hermann; Wiethoelter, Horst; Dietz, Klaus; Mallot, Hanspeter A; Schiefer, Ulrich

    2012-01-01

    The aim of the present study was to examine the effect of homonymous visual field defects (HVFDs) on collision avoidance of dynamic obstacles at an intersection under virtual reality (VR) conditions. Overall performance was quantitatively assessed as the number of collisions at a virtual intersection at two difficulty levels. HVFDs were assessed by binocular semi-automated kinetic perimetry within the 90° visual field, stimulus III4e and the area of sparing within the affected hemifield (A-SPAR in deg(2)) was calculated. The effect of A-SPAR, age, gender, side of brain lesion, time since brain lesion and presence of macular sparing on the number of collisions, as well as performance over time were investigated. Thirty patients (10 female, 20 male, age range: 19-71 years) with HVFDs due to unilateral vascular brain lesions and 30 group-age-matched subjects with normal visual fields were examined. The mean number of collisions was higher for patients and in the more difficult level they experienced more collisions with vehicles approaching from the blind side than the seeing side. Lower A-SPAR and increasing age were associated with decreasing performance. However, in agreement with previous studies, wide variability in performance among patients with identical visual field defects was observed and performance of some patients was similar to that of normal subjects. Both patients and healthy subjects displayed equal improvement of performance over time in the more difficult level. In conclusion, our results suggest that visual-field related parameters per se are inadequate in predicting successful collision avoidance. Individualized approaches which also consider compensatory strategies by means of eye and head movements should be introduced. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Organization of area hV5/MT+ in subjects with homonymous visual field defects.

    PubMed

    Papanikolaou, Amalia; Keliris, Georgios A; Papageorgiou, T Dorina; Schiefer, Ulrich; Logothetis, Nikos K; Smirnakis, Stelios M

    2018-04-06

    Damage to the primary visual cortex (V1) leads to a visual field loss (scotoma) in the retinotopically corresponding part of the visual field. Nonetheless, a small amount of residual visual sensitivity persists within the blind field. This residual capacity has been linked to activity observed in the middle temporal area complex (V5/MT+). However, it remains unknown whether the organization of hV5/MT+ changes following early visual cortical lesions. We studied the organization of area hV5/MT+ of five patients with dense homonymous defects in a quadrant of the visual field as a result of partial V1+ or optic radiation lesions. To do so, we developed a new method, which models the boundaries of population receptive fields directly from the BOLD signal of each voxel in the visual cortex. We found responses in hV5/MT+ arising inside the scotoma for all patients and identified two possible sources of activation: 1) responses might originate from partially lesioned parts of area V1 corresponding to the scotoma, and 2) responses can also originate independent of area V1 input suggesting the existence of functional V1-bypassing pathways. Apparently, visually driven activity observed in hV5/MT+ is not sufficient to mediate conscious vision. More surprisingly, visually driven activity in corresponding regions of V1 and early extrastriate areas including hV5/MT+ did not guarantee visual perception in the group of patients with post-geniculate lesions that we examined. This suggests that the fine coordination of visual activity patterns across visual areas may be an important determinant of whether visual perception persists following visual cortical lesions. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. A comparison of semiautomated versus manual Goldmann kinetic perimetry in patients with visually significant glaucoma.

    PubMed

    Ramirez, Adriana M; Chaya, Craig J; Gordon, Lynn K; Giaconi, Joann A

    2008-03-01

    To determine if semiautomated kinetic perimetry (SKP) is reproducible and comparable to Goldmann manual kinetic perimetry (GVF). Glaucoma patients were recruited to perform visual field testing using GVF and SKP. Specific isopters were tested, quantified, and compared. Visual field patterns were analyzed for shape and defect. Ten patients (16 eyes) underwent visual field studies using SKP and GVF, and 8 patients completed a second SKP on a different day. Individual isopter areas were similar between GVF and SKP, although 60% of isopters were larger on SKP by an average of 15%. This was statistically significant for the smaller isopters, I4e (P=0.02) and I2e (P=0.05). Retesting with SKP on a separate day, showed similar isopter areas (P values=0.3 to 1.0), however, the exact location of isopters in degrees from central fixation tended to vary with the smaller test object sizes. Isopter position in degrees from the central axis agreed in at least 3 quadrants in approximately 65% of fields compared. SKP visual field defects and patterns were similar between test strategies. SKP and GVF testing produce similar visual field results in glaucoma patients, and SKP testing seems to be reliable and reproducible in this population. However, overlapping isopters, typically associated with nonorganic vision loss, and jagged isopters were sometimes observed in SKP visual fields. Further study of SKP is needed to explore these findings.

  4. Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with polarimetry and spectral domain OCT.

    PubMed

    Horn, Folkert K; Mardin, Christian Y; Laemmer, Robert; Baleanu, Delia; Juenemann, Anselm M; Kruse, Friedrich E; Tornow, Ralf P

    2009-05-01

    To study the correlation between local perimetric field defects and glaucoma-induced thickness reduction of the nerve layer measured in the peripapillary area with scanning laser polarimetry (SLP) and spectral domain optical coherence tomography (SOCT) and to compare the results with those of a theoretical model. The thickness of the retinal nerve fiber layer was determined in 32 sectors (11.25 degrees each) by using SLP with variable cornea compensation (GDxVCC; Laser Diagnostics, San Diego, CA) and the newly introduced high-resolution SOCT (Spectralis; Heidelberg Engineering, Heidelberg, Germany). Eighty-eight healthy subjects served as control subjects, to determine the thickness deviation in patients with glaucoma. The relationship between glaucomatous nerve fiber reduction and visual field losses was calculated in six nerve fiber bundle-related areas. Sixty-four patients at different stages of open-angle glaucoma and 26 patients with ocular hypertension underwent perimetry (Octopus G1; Haag-Streit, Köniz, Switzerland) and measurements with the two morphometric techniques. Sector-shaped analyses between local perimetric losses and reduction of the retinal nerve fiber layer thickness showed a significant association for corresponding areas except for the central visual field in SLP. Correlation coefficients were highest in the area of the nasal inferior visual field (SOCT, -0.81; SLP, -0.57). A linear model describes the association between structural and functional damage. Localized perimetric defects can be explained by reduced nerve fiber layer thickness. The data indicate that the present SOCT is useful for determining the functional-structural relationship in peripapillary areas and that association between perimetric defects and corresponding nerve fiber losses is stronger for SOCT than for the present SLP. (ClinicalTrials.gov number, NCT00494923.).

  5. Rate of progression of total, upper, and lower visual field defects in patients with open-angle glaucoma and high myopia.

    PubMed

    Yoshino, Takaiko; Fukuchi, Takeo; Togano, Tetsuya; Sakaue, Yuta; Seki, Masaaki; Tanaka, Takayuki; Ueda, Jun

    2016-03-01

    We evaluated the rate of progression of total, upper, and lower visual field defects in patients with treated primary open-angle glaucoma (POAG) with high myopia (HM). Seventy eyes of 70 POAG patients with HM [≤-8 diopters (D)] were examined. The mean deviation (MD) slope and the upper and lower total deviation (upper TD, lower TD) slopes of the Humphrey Field Analyzer were calculated in patients with high-tension glaucoma (HTG) (>21 mmHg) versus normal-tension glaucoma (NTG) (≤21 mmHg). The mean age of all the patients (29 eyes with HTG and 41 eyes with NTG) was 48.5 ± 9.6 years. The MD slope, and upper and lower TD slopes of the HM group were compared to those of the non-HM group (NHM) (>-8 D) selected from 544 eyes in 325 age-matched POAG patients. In all, 70 eyes with HM and NHM were examined. The mean MD slope was -0.33 ± 0.33 dB/year in the HM, and -0.38 ± 0.49 dB/year in the NHM. There were no statistical differences between the HM and NHM (p = 0.9565). In the comparison of HTG versus NTG patients in both groups, the MD slope, and upper and lower TD slopes were similar. The rate of progression of total, upper, and lower visual field defects was similar among patients with HM and NHM. Although HM is a risk factor for the onset of glaucoma, HM may not be a risk factor for progression of visual field defects as assessed by the progression rate under treatment.

  6. Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect.

    PubMed

    Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel

    2015-12-01

    To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.

  7. Anatomical Origin of Tuberculum Sellae Meningioma: Off-Midline Location and Its Clinical Implications.

    PubMed

    Lee, Seungjoo; Hong, Seok Ho; Cho, Young Hyun; Kim, Jeong Hoon; Kim, Chang Jin

    2016-05-01

    Tuberculum sellae meningiomas (TSM) arise from the dura mater of tuberculum sellae, limbus sphenoidale, and chiasmatic sulcus and cause asymmetric visual disturbances. In this study, we analyzed the laterality of the origin of TSM and discussed its clinical implications on immediate and long-term visual outcomes. Between 1994 and 2013, TSM was diagnosed in 100 patients after microsurgical resection. The medical records, radiologic features, and operative findings were retrospectively reviewed and analyzed in these patients. Visual disturbances were evident in 95 patients (95%) after neuro-ophthalmologic testing. Among them, 89 patients (89%) showed marked asymmetric visual field defect, and 6 patients (6%) had relatively symmetric visual field defect. On intraoperative inspection, the origin of TSM was at the one lateral end portion of the tuberculum sellae in 85 patients (85%). In 15 patients (15%), the TSM originated from the midline region, including the central portion of the tuberculum sellae (n = 13) and diaphragm sellae (n = 2). Optic canal involvement was observed in 73 patients (73%). Preexisting visual field defects were improved in 70 patients (70%), were stationary in 25 patients (25%), and aggravated in 5 patients (5%) during postoperative follow-up (mean 58 months, 24∼122 months). The preoperative symptom duration, the laterality of the origin of TSM, and optic disc atrophy were associated with long-term poor visual outcomes. Most TSMs that originated from the dura of one lateral end portion of the tuberculum sellae correlated with asymmetric visual symptoms and poor visual outcomes. This microsurgical feature should be considered in the planning of optimal surgical strategy to achieve favorable outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Are Hemianopic Reading and Visual Exploration Impairments Visually Elicited? New Insights from Eye Movements in Simulated Hemianopia

    ERIC Educational Resources Information Center

    Schuett, Susanne; Kentridge, Robert W.; Zihl, Josef; Heywood, Charles A.

    2009-01-01

    Hemianopic reading and visual exploration impairments are well-known clinical phenomena. Yet, it is unclear whether they are primarily caused by the hemianopic visual field defect itself or by additional brain injury preventing efficient spontaneous oculomotor adaptation. To establish the extent to which these impairments are visually elicited we…

  9. Design of an aid to visual inspection workstation

    NASA Astrophysics Data System (ADS)

    Tait, Robert; Harding, Kevin

    2016-05-01

    Visual Inspection is the most common means for inspecting manufactured parts for random defects such as pits, scratches, breaks, corrosion or general wear. The reason for the need for visual inspection is the very random nature of what might be a defect. Some defects may be very rare, being seen once or twice a year, but May still be critical to part performance. Because of this random and rare nature, even the most sophisticated image analysis programs have not been able to recognize all possible defects. Key to any future automation of inspection is obtaining good sample images of what might be a defect. However, most visual check take no images and consequently generate no digital data or historical record beyond a simple count. Any additional tool to captures such images must be able to do so without taking addition time. This paper outlines the design of a potential visual inspection station that would be compatible with current visual inspection methods, but afford the means for reliable digital imaging and in many cases augmented capabilities to assist the inspection. Considerations in this study included: resolution, depth of field, feature highlighting, and ease of digital capture, annotations and inspection augmentation for repeatable registration as well as operator assistance and training.

  10. Visual field recovery after vision restoration therapy (VRT) is independent of eye movements: an eye tracker study.

    PubMed

    Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A

    2006-11-25

    It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.

  11. Comparison of standard automated perimetry with matrix frequency-doubling technology in patients with resolved optic neuritis.

    PubMed

    Sakai, Tsutomu; Matsushima, Masato; Shikishima, Keigo; Kitahara, Kenji

    2007-05-01

    To examine performance characteristics of frequency-doubling perimetry (FDP) in comparison with standard automated perimetry (SAP) in patients with resolved optic neuritis in a short-term follow-up study. Comparative consecutive case series. Twenty patients with resolved optic neuritis and 20 healthy volunteers participated in this study. The subjects were patients who recovered normal vision (1.0 or better) after optic neuritis. The Swedish interactive thresholding algorithm 30-2 program was used for SAP and a full-threshold 30-2 program was used for FDP. Using both forms of perimetry, the mean deviation (MD), pattern standard deviation (PSD), and the percentage of abnormal points significantly depressed <0.5% in the total deviation probability plot were compared. The visual fields were divided into 5 zones, and the mean sensitivity in each zone in affected eyes was compared with that in healthy eyes of the volunteers within 2 weeks of vision recovery and in follow-up after 2 weeks and 2 and 5 months. Standard automated perimetry and FDP showed general depression in the fovea and extrafoveal areas. Correlations between SAP and FDP were statistically significant for MD (Pearson r>0.75; P<0.001) and PSD (r>0.6; P<0.005). Defects detected with FDP were larger than with SAP in 14 eyes (70 %). In follow-up after 2 weeks and again after 2 and 5 months, FDP indicated slower improvement in visual field defects in the fovea and extrafoveal areas, whereas SAP indicated rapid improvement in these defects. Frequency-doubling perimetry is at least comparable with and potentially more sensitive than SAP in detecting visual field defects in resolved optic neuritis. This short-term follow-up study in patients with resolved optic neuritis suggests that FDP detects characteristics of slower recovery more effectively than SAP in the fovea and extrafoveal areas. These properties may allow more accurate detection of visual field defects and may prove advantageous for monitoring of patients with resolved optic neuritis.

  12. Effect of Ginkgo biloba on visual field and contrast sensitivity in Chinese patients with normal tension glaucoma: a randomized, crossover clinical trial.

    PubMed

    Guo, Xinxing; Kong, Xiangbin; Huang, Rui; Jin, Ling; Ding, Xiaohu; He, Mingguang; Liu, Xing; Patel, Mehul Chimanlal; Congdon, Nathan G

    2014-01-07

    We evaluated the effect of ginkgo biloba extract on visual field defect and contrast sensitivity in a Chinese cohort with normal tension glaucoma. In this prospective, randomized, placebo-controlled crossover study, patients newly diagnosed with normal tension glaucoma, either in a tertiary glaucoma clinic (n = 5) or in a cohort undergoing routine general physical examinations in a primary care clinic (n = 30), underwent two 4-week phases of treatment, separated by a washout period of 8 weeks. Randomization determined whether ginkgo biloba extract (40 mg, 3 times per day) or placebo (identical-appearing tablets) was received first. Primary outcomes were change in contrast sensitivity and mean deviation on 24-2 SITA standard visual field testing, while secondary outcomes included IOP and self-reported adverse events. A total of 35 patients with mean age 63.7 (6.5) years were randomized to the ginkgo biloba extract-placebo (n = 18) or the placebo-ginkgo biloba extract (n = 17) sequence. A total of 28 patients (80.0%, 14 in each group) who completed testing did not differ at baseline in age, sex, visual field mean deviation, contrast sensitivity, IOP, or blood pressure. Changes in visual field and contrast sensitivity did not differ by treatment received or sequence (P > 0.2 for all). Power to have detected a difference in mean defect as large as previously reported was 80%. In contrast to some previous reports, ginkgo biloba extract treatment had no effect on mean defect or contrast sensitivity in this group of normal tension glaucoma patients. (http://www.chictr.org number, ChiCTR-TRC-08000724).

  13. Quasi-conformal remapping for compensation of human visual field defects - Advances in image remapping for human field defects

    NASA Technical Reports Server (NTRS)

    Juday, Richard D.; Loshin, David S.

    1989-01-01

    Image coordinate transformations are investigated for possible use in a low vision aid for human patients. These patients typically have field defects with localized retinal dysfunction predominately central (age related maculopathy) or peripheral (retinitis pigmentosa). Previously simple eccentricity-only remappings which do not maintain conformality were shown. Initial attempts on developing images which hold quasi-conformality after remapping are presented. Although the quasi-conformal images may have less local distortion, there are discontinuities in the image which may counterindicate this type of transformation for the low vision application.

  14. Mobility scooter driving ability in visually impaired individuals.

    PubMed

    Cordes, Christina; Heutink, Joost; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M

    2018-06-01

    To investigate how well visually impaired individuals can learn to use mobility scooters and which parts of the driving task deserve special attention. A mobility scooter driving skill test was developed to compare driving skills (e.g. reverse driving, turning) between 48 visually impaired (very low visual acuity = 14, low visual acuity = 10, peripheral field defects = 11, multiple visual impairments = 13) and 37 normal-sighted controls without any prior experience with mobility scooters. Performance on this test was rated on a three-point scale. Furthermore, the number of extra repetitions on the different elements were noted. Results showed that visually impaired participants were able to gain sufficient driving skills to be able to use mobility scooters. Participants with visual field defects combined with low visual acuity showed most problems learning different skills and needed more training. Reverse driving and stopping seemed to be most difficult. The present findings suggest that visually impaired individuals are able to learn to drive mobility scooters. Mobility scooter allocators should be aware that these individuals might need more training on certain elements of the driving task. Implications for rehabilitation Visual impairments do not necessarily lead to an inability to acquire mobility scooter driving skills. Individuals with peripheral field defects (especially in combination with reduced visual acuity) need more driving ability training compared to normal-sighted people - especially to accomplish reversing. Individual assessment of visually impaired people is recommended, since participants in this study showed a wide variation in ability to learn driving a mobility scooter.

  15. [Case of brain infarction in the anterior choroidal artery territory with homonymous scotomas].

    PubMed

    Nakae, Yoshiharu; Higashiyama, Yuichi; Kuroiwa, Yoshiyuki

    2009-08-01

    We report a case of brain infarction in the anterior choroidal artery territory accompanied homonymous scotomas. A 59-year-old man with diabetes mellitus felt weakness in his left upper and lower extremities. He was admitted to our hospital with mild hemiparesis on his left side. He noticed a small black spot in the left inferior portion of his visual field; however, this disappeared within one minute. He had no visual defects as assessed by a confrontation test, but a Goldmann visual field test revealed that there were homonymous scotomas in the left inferior portion of the visual field. Brain MRI showed hyperintense signals on diffusion-weighted images in the territory of the right anterior choroidal artery. He was diagnosed as having a brain infarction. The anterior choroidal artery penetrates the lateral geniculate nucleus from the front, and branches of the artery usually supply the medial and lateral parts of the lateral geniculate nucleus. Occlusion of these branches causes the loss of the upper and lower homonymous sectors in the visual field. The present case exhibited homonymous scotomas. We assumed that our patient's homonymous scotomas were a variant form of wedge-shaped visual field deficits often seen in anterior choroidal artery syndrome. On the basis the experience gained in this case, we consider that patients with brain infarction in the anterior choroidal artery territory should undergo ophthalmological examination, even when no visual defects are detected by a confrontation test.

  16. Visual functions of commercial drivers in relation to road accidents in Nigeria

    PubMed Central

    Oladehinde, M. K.; Adeoye, A. O.; Adegbehingbe, B. O.; Onakoya, A. O.

    2007-01-01

    Objective: To determine the effects of the visual functions on the occurrence of road traffic accidents (RTA) amongst commercial drivers in Ife central local government area (LGA) of Osun state of Nigeria. Design: A cross-sectional study. Settings: Four major motor parks located at Ife Central LGA. Materials and Methods: Of the estimated 270 commercial drivers in the four major parks of the LGA, 215 consecutive drivers were interviewed and had their eyes examined. Structured questionnaires were administered by an ophthalmologist. Results: The prevalence of visual impairment (visual acuity < 6/18) in the better eye without correction was 3.3% ± 2.4 and there was a significant association between uncorrected visual acuity impairment in the better eye and RTA (P = 0.0152). Refractive error was seen in 8.4% of the drivers, but none of these wear corrective glasses. Visual field defect, abnormal stereopsis and color vision impairment did not have any significant association with RTA. Conclusion: Poor visual acuity is strongly associated with RTA amongst Nigerian commercial drivers as opposed to visual field defect, abnormal color vision and stereopsis. A significant proportion of visual impairment was due to uncorrected refractive errors. PMID:21938219

  17. Visual brain plasticity induced by central and peripheral visual field loss.

    PubMed

    Sanda, Nicolae; Cerliani, Leonardo; Authié, Colas N; Sabbah, Norman; Sahel, José-Alain; Habas, Christophe; Safran, Avinoam B; Thiebaut de Schotten, Michel

    2018-06-23

    Disorders that specifically affect central and peripheral vision constitute invaluable models to study how the human brain adapts to visual deafferentation. We explored cortical changes after the loss of central or peripheral vision. Cortical thickness (CoTks) and resting-state cortical entropy (rs-CoEn), as a surrogate for neural and synaptic complexity, were extracted in 12 Stargardt macular dystrophy, 12 retinitis pigmentosa (tunnel vision stage), and 14 normally sighted subjects. When compared to controls, both groups with visual loss exhibited decreased CoTks in dorsal area V3d. Peripheral visual field loss also showed a specific CoTks decrease in early visual cortex and ventral area V4, while central visual field loss in dorsal area V3A. Only central visual field loss exhibited increased CoEn in LO-2 area and FG1. Current results revealed biomarkers of brain plasticity within the dorsal and the ventral visual streams following central and peripheral visual field defects.

  18. Saccadic vector optokinetic perimetry in children with neurodisability or isolated visual pathway lesions: observational cohort study.

    PubMed

    Tailor, Vijay; Glaze, Selina; Unwin, Hilary; Bowman, Richard; Thompson, Graham; Dahlmann-Noor, Annegret

    2016-10-01

    Children and adults with neurological impairments are often not able to access conventional perimetry; however, information about the visual field is valuable. A new technology, saccadic vector optokinetic perimetry (SVOP), may have improved accessibility, but its accuracy has not been evaluated. We aimed to explore accessibility, testability and accuracy of SVOP in children with neurodisability or isolated visual pathway deficits. Cohort study; recruitment October 2013-May 2014, at children's eye clinics at a tertiary referral centre and a regional Child Development Centre; full orthoptic assessment, SVOP (central 30° of the visual field) and confrontation visual fields (CVF). Group 1: age 1-16 years, neurodisability (n=16), group 2: age 10-16 years, confirmed or suspected visual field defect (n=21); group 2 also completed Goldmann visual field testing (GVFT). Group 1: testability with a full 40-point test protocol is 12.5%; with reduced test protocols, testability is 100%, but plots may be clinically meaningless. Children (44%) and parents/carers (62.5%) find the test easy. SVOP and CVF agree in 50%. Group 2: testability is 62% for the 40-point protocol, and 90.5% for reduced protocols. Corneal changes in childhood glaucoma interfere with SVOP testing. All children and parents/carers find SVOP easy. Overall agreement with GVFT is 64.7%. While SVOP is highly accessible to children, many cannot complete a full 40-point test. Agreement with current standard tests is moderate to poor. Abnormal saccades cause an apparent non-specific visual field defect. In children with glaucoma or nystagmus SVOP calibration often fails. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Interocular asymmetry of the visual field defects in newly diagnosed normal-tension glaucoma, primary open-angle glaucoma, and chronic angle-closure glaucoma.

    PubMed

    Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun

    2014-09-01

    To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P<0.05). CACG group had greater total MD interocular asymmetry score compared with the NTG and POAG groups (among groups, P=0.008; NTG vs. CACG, P=0.005; POAG vs. CACG, P=0.009). CACG also presented with significantly higher local MD interocular asymmetry scores at central, inferior, and temporal areas compared with those of the POAG group and at inferior area compared with that of NTG group. No significant difference in either total or local MDs was detected between NTG and POAG (all P>0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.

  20. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  1. Purtscher's retinopathy associated with acute pancreatitis.

    PubMed

    Hamp, Ania M; Chu, Edward; Slagle, William S; Hamp, Robert C; Joy, Jeffrey T; Morris, Robert W

    2014-02-01

    Purtscher's retinopathy is a rare condition that is associated with complement-activating systemic diseases such as acute pancreatitis. After pancreatic injury or inflammation, proteases such as trypsin activate the complement system and can potentially cause coagulation and leukoembolization of retinal precapillary arterioles. Specifically, intermediate-sized emboli are sufficiently small enough to pass through larger arteries yet large enough to remain lodged in precapillary arterioles and cause the clinical appearance of Purtscher's retinopathy. This pathology may present with optic nerve edema, impaired visual acuity, visual field loss, as well as retinal findings such as cotton-wool spots, retinal hemorrhage, artery attenuation, venous dilation, and Purtscher flecken. A 57-year-old white man presented with an acute onset of visual field scotomas and decreased visual acuity 1 week after being hospitalized for acute pancreatitis. The retinal examination revealed multiple regions of discrete retinal whitening surrounding the disk, extending through the macula bilaterally, as well as bilateral optic nerve hemorrhages. The patient identified paracentral bilateral visual field defects on Amsler Grid testing, which was confirmed with subsequent Humphrey visual field analysis. Although the patient presented with an atypical underlying etiology, he exhibited classic retinal findings for Purtscher's retinopathy. After 2 months, best corrected visual acuity improved and the retinal whitening was nearly resolved; however, bilateral paracentral visual field defects remained. Purtscher's retinopathy has a distinctive clinical presentation and is typically associated with thoracic trauma but may be a sequela of nontraumatic systemic disease such as acute pancreatitis. Patients diagnosed with acute pancreatitis should have an eye examination to rule out Purtscher's retinopathy. Although visual improvement is possible, patients should be educated that there may be permanent ocular sequelae.

  2. Charles Bonnet syndrome in hemianopia, following antero-mesial temporal lobectomy for drug-resistant epilepsy.

    PubMed

    Contardi, Sara; Rubboli, Guido; Giulioni, Marco; Michelucci, Roberto; Pizza, Fabio; Gardella, Elena; Pinardi, Federica; Bartolomei, Ilaria; Tassinari, Carlo Alberto

    2007-09-01

    Charles Bonnet syndrome (CBS) is a disorder characterized by the occurrence of complex visual hallucinations in patients with acquired impairment of vision and without psychiatric disorders. In spite of the high incidence of visual field defects following antero-mesial temporal lobectomy for refractory temporal lobe epilepsy, reports of CBS in patients who underwent this surgical procedure are surprisingly rare. We describe a patient operated on for drug-resistant epilepsy. As a result of left antero-mesial temporal resection, she presented right homonymous hemianopia. A few days after surgery, she started complaining of visual hallucinations, such as static or moving "Lilliputian" human figures, or countryside scenes, restricted to the hemianopic field. The patient was fully aware of their fictitious nature. These disturbances disappeared progressively over a few weeks. The incidence of CBS associated with visual field defects following epilepsy surgery might be underestimated. Patients with post-surgical CBS should be reassured that it is not an epileptic phenomenon, and that it has a benign, self-limiting, course which does not usually require treatment.

  3. Quasi-Conformal Remapping For Compensation Of Human Visual Field Defects: Advances In Image Remapping For Human Field Defects

    NASA Astrophysics Data System (ADS)

    Juday, Richard D.; Loshin, David S.

    1989-06-01

    We are investigating image coordinate transformations possibly to be used in a low vision aid for human patients. These patients typically have field defects with localized retinal dysfunction predominately central (age related maculopathy) or peripheral (retinitis pigmentosa). Previously we have shown simple eccentricity-only remappings which do not maintain conformality. In this report we present our initial attempts on developing images which hold quasi-conformality after remapping. Although the quasi-conformal images may have less local distortion, there are discontinuities in the image which may counterindicate this type of transformation for the low vision application.

  4. Cranial Nerve II

    PubMed Central

    Gillig, Paulette Marie; Sanders, Richard D.

    2009-01-01

    This article contains a brief review of the anatomy of the visual system, a survey of diseases of the retina, optic nerve and lesions of the optic chiasm, and other visual field defects of special interest to the psychiatrist. It also includes a presentation of the corticothalamic mechanisms, differential diagnosis, and various manifestations of visual illusions, and simple and complex visual hallucinations, as well as the differential diagnoses of these various visual phenomena. PMID:19855858

  5. Predictive factors of visual function recovery after pituitary adenoma resection: a literature review and Meta-analysis.

    PubMed

    Sun, Min; Zhang, Zhi-Qiang; Ma, Chi-Yuan; Chen, Sui-Hua; Chen, Xin-Jian

    2017-01-01

    To determine the dominant predictive factors of postoperative visual recovery for patients with pituitary adenoma. PubMed, Google Scholar, Web of Science and Cochrane Library were searched for relevant human studies, which investigated the prediction of the postoperative visual recovery of patients with pituitary adenoma, from January 2000 to May 2017. Meta-analyses were performed on the primary outcomes. After the related data were extracted by two independent investigators, pooled weighted mean difference (WMD) and odds ratio (OR) with 95% confidence interval (CI) were estimated using a random-effects or a fixed-effects model. Nineteen studies were included in the literature review, and nine trials were included in the Meta-analysis, which comprised 530 patients (975 eyes) with pituitary adenoma. For the primary outcomes, there was a significant difference between preoperative and postoperative mean deviation (MD) values of the visual field (WMD -5.85; 95%CI: -8.19 to -3.51; P <0.00001). Predictive characteristics of four factors were revealed in this Meta-analysis by assigning the patients to sufficient and insufficient groups according to postoperative visual field improvements, including preoperative visual field defect (WMD 10.09; 95%CI: 6.17 to 14.02; P <0.00001), patient age (WMD -12.32; 95%CI: -18.42 to -6.22; P <0.0001), symptom duration (WMD -5.04; 95%CI: -9.71 to -0.37; P =0.03), and preoperative peripapillary retinal nerve fiber layer (pRNFL) thickness (OR 0.1; 95% CI: 0.04 to 0.23; P <0.00001). Preoperative visual field defect, symptom duration, patient age, and preoperative pRNFL thickness are the dominant predictive factors of the postoperative recovery of the visual field for patients with pituitary adenoma.

  6. Diagnosing cerebral visual impairment in children with good visual acuity.

    PubMed

    van Genderen, Maria; Dekker, Marjoke; Pilon, Florine; Bals, Irmgard

    2012-06-01

    To identify elements that could facilitate the diagnosis of cerebral visual impairment (CVI) in children with good visual acuity in the general ophthalmic clinic. We retrospectively investigated the clinical characteristics of 30 children with good visual acuity and CVI and compared them with those of 23 children who were referred with a suspicion of CVI, but proved to have a different diagnosis. Clinical characteristics included medical history, MRI findings, visual acuity, crowding ratio (CR), visual field assessment, and the results of ophthalmologic and orthoptic examination. We also evaluated the additional value of a short CVI questionnaire. Eighty-three percent of the children with an abnormal medical history (mainly prematurity and perinatal hypoxia) had CVI, in contrast with none of the children with a normal medical history. Cerebral palsy, visual field defects, and partial optic atrophy only occurred in the CVI group. 41% of the children with CVI had a CR ≥2.0, which may be related to dorsal stream dysfunction. All children with CVI, but also 91% of the children without CVI gave ≥3 affirmative answers on the CVI questionnaire. An abnormal pre- or perinatal medical history is the most important risk factor for CVI in children, and therefore in deciding which children should be referred for further multidisciplinary assessment. Additional symptoms of cerebral damage, i.e., cerebral palsy, visual field defects, partial optic atrophy, and a CR ≥2 may support the diagnosis. CVI questionnaires should not be used for screening purposes as they yield too many false positives.

  7. Lack of Multisensory Integration in Hemianopia: No Influence of Visual Stimuli on Aurally Guided Saccades to the Blind Hemifield

    PubMed Central

    Ten Brink, Antonia F.; Nijboer, Tanja C. W.; Bergsma, Douwe P.; Barton, Jason J. S.; Van der Stigchel, Stefan

    2015-01-01

    In patients with visual hemifield defects residual visual functions may be present, a phenomenon called blindsight. The superior colliculus (SC) is part of the spared pathway that is considered to be responsible for this phenomenon. Given that the SC processes input from different modalities and is involved in the programming of saccadic eye movements, the aim of the present study was to examine whether multimodal integration can modulate oculomotor competition in the damaged hemifield. We conducted two experiments with eight patients who had visual field defects due to lesions that affected the retinogeniculate pathway but spared the retinotectal direct SC pathway. They had to make saccades to an auditory target that was presented alone or in combination with a visual stimulus. The visual stimulus could either be spatially coincident with the auditory target (possibly enhancing the auditory target signal), or spatially disparate to the auditory target (possibly competing with the auditory tar-get signal). For each patient we compared the saccade endpoint deviation in these two bi-modal conditions with the endpoint deviation in the unimodal condition (auditory target alone). In all seven hemianopic patients, saccade accuracy was affected only by visual stimuli in the intact, but not in the blind visual field. In one patient with a more limited quadrantano-pia, a facilitation effect of the spatially coincident visual stimulus was observed. We conclude that our results show that multisensory integration is infrequent in the blind field of patients with hemianopia. PMID:25835952

  8. How do patients with neglect see a horizontal line? Analysis of performances in coloured line bisection task.

    PubMed

    Misonou, Kaori; Ishiai, Sumio; Seki, Keiko; Koyama, Yasumasa; Nakano, Naomi

    2004-06-01

    Twelve patients with left unilateral spatial neglect were examined with a newly devised "coloured line bisection task". They were presented with a horizontal line printed in blue on one side and in red on the other side; the proportions of the blue and red segments were varied. Immediately after placement of the subjective midpoint, the line was concealed and the patients were asked to name the colours of the right and left ends. Five patients who identified the left-end colour almost correctly had no visual field defect, while the other seven whose colour naming was impaired on the left side had left visual field defect. The rightward bisection errors were similarly distributed in the fair and poor colour-naming patients except for two patients from the latter group. The lesions of the fair colour-naming patients spared the lingual and fusiform gyri, which are known to be engaged in colour processing. Patients with neglect whose visual field is preserved may neglect the leftward extension of a line but not the colour in the neglected space. The poor colour-naming patients frequently failed to name the left-end colour that appeared to the left of their subjective midpoint, which indicates that they hardly searched leftward beyond that point. In such trials, they reported that the left end had the same colour as the right end. The results suggest that in patients with neglect and left visual field defect, both the leftward extent and the colour of a line may be represented on the basis of the information from the attended right segment.

  9. Normal versus High Tension Glaucoma: A Comparison of Functional and Structural Defects

    PubMed Central

    Thonginnetra, Oraorn; Greenstein, Vivienne C.; Chu, David; Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.

    2009-01-01

    Purpose To compare visual field defects obtained with both multifocal visual evoked potential (mfVEP) and Humphrey visual field (HVF) techniques to topographic optic disc measurements in patients with normal tension glaucoma (NTG) and high tension glaucoma (HTG). Methods We studied 32 patients with NTG and 32 with HTG. All patients had reliable 24-2 HVFs with a mean deviation (MD) of −10 dB or better, a glaucomatous optic disc and an abnormal HVF in at least one eye. Multifocal VEPs were obtained from each eye and probability plots created. The mfVEP and HVF probability plots were divided into a central 10-degree (radius) and an outer arcuate subfield in both superior and inferior hemifields. Cluster analyses and counts of abnormal points were performed in each subfield. Optic disc images were obtained with the Heidelberg Retina Tomograph III (HRT III). Eleven stereometric parameters were calculated. Moorfields regression analysis (MRA) and the glaucoma probability score (GPS) were performed. Results There were no significant differences in MD and PSD values between NTG and HTG eyes. However, NTG eyes had a higher percentage of abnormal test points and clusters of abnormal points in the central subfields on both mfVEP and HVF than HTG eyes. For HRT III, there were no significant differences in the 11 stereometric parameters or in the MRA and GPS analyses of the optic disc images. Conclusions The visual field data suggest more localized and central defects for NTG than HTG. PMID:19223786

  10. Multifocal visual evoked potential in optic neuritis, ischemic optic neuropathy and compressive optic neuropathy

    PubMed Central

    Jayaraman, Manju; Gandhi, Rashmin Anilkumar; Ravi, Priya; Sen, Parveen

    2014-01-01

    Purpose: To investigate the effect of optic neuritis (ON), ischemic optic neuropathy (ION) and compressive optic neuropathy (CON) on multifocal visual evoked potential (mfVEP) amplitudes and latencies, and to compare the parameters among three optic nerve disorders. Materials and Methods: mfVEP was recorded for 71 eyes of controls and 48 eyes of optic nerve disorders with subgroups of optic neuritis (ON, n = 21 eyes), ischemic optic neuropathy (ION, n = 14 eyes), and compressive optic neuropathy (CON, n = 13 eyes). The size of defect in mfVEP amplitude probability plots and relative latency plots were analyzed. The pattern of the defect in amplitude probability plot was classified according to the visual field profile of optic neuritis treatment trail (ONTT). Results: Median of mfVEP amplitude (log SNR) averaged across 60 sectors were reduced in ON (0.17 (0.13-0.33)), ION (0.14 (0.12-0.21)) and CON (0.21 (0.14-0.30)) when compared to controls. The median mfVEP relative latencies compared to controls were significantly prolonged in ON and CON group of 10.53 (2.62-15.50) ms and 5.73 (2.67-14.14) ms respectively compared to ION group (2.06 (-4.09-13.02)). The common mfVEP amplitude defects observed in probability plots were diffuse pattern in ON, inferior altitudinal defect in ION and temporal hemianopia in CON eyes. Conclusions: Optic nerve disorders cause reduction in mfVEP amplitudes. The extent of delayed latency noted in ischemic optic neuropathy was significantly lesser compared to subjects with optic neuritis and compressive optic neuropathy. mfVEP amplitudes can be used to objectively assess the topography of the visual field defect. PMID:24088641

  11. The repeatability of mean defect with size III and size V standard automated perimetry.

    PubMed

    Wall, Michael; Doyle, Carrie K; Zamba, K D; Artes, Paul; Johnson, Chris A

    2013-02-15

    The mean defect (MD) of the visual field is a global statistical index used to monitor overall visual field change over time. Our goal was to investigate the relationship of MD and its variability for two clinically used strategies (Swedish Interactive Threshold Algorithm [SITA] standard size III and full threshold size V) in glaucoma patients and controls. We tested one eye, at random, for 46 glaucoma patients and 28 ocularly healthy subjects with Humphrey program 24-2 SITA standard for size III and full threshold for size V each five times over a 5-week period. The standard deviation of MD was regressed against the MD for the five repeated tests, and quantile regression was used to show the relationship of variability and MD. A Wilcoxon test was used to compare the standard deviations of the two testing methods following quantile regression. Both types of regression analysis showed increasing variability with increasing visual field damage. Quantile regression showed modestly smaller MD confidence limits. There was a 15% decrease in SD with size V in glaucoma patients (P = 0.10) and a 12% decrease in ocularly healthy subjects (P = 0.08). The repeatability of size V MD appears to be slightly better than size III SITA testing. When using MD to determine visual field progression, a change of 1.5 to 4 decibels (dB) is needed to be outside the normal 95% confidence limits, depending on the size of the stimulus and the amount of visual field damage.

  12. Mental Images and the Modification of Learning Defects.

    ERIC Educational Resources Information Center

    Patten, Bernard M.

    Because human memory and thought involve extremely complex processes, it is possible to employ unusual modalities and specific visual strategies for remembering and problem-solving to assist patients with memory defects. This three-part paper discusses some of the research in the field of human memory and describes practical applications of these…

  13. A lightning strike to the head causing a visual cortex defect with simple and complex visual hallucinations

    PubMed Central

    Kleiter, Ingo; Luerding, Ralf; Diendorfer, Gerhard; Rek, Helga; Bogdahn, Ulrich; Schalke, Berthold

    2007-01-01

    The case of a 23‐year‐old mountaineer who was hit by a lightning strike to the occiput causing a large central visual field defect and bilateral tympanic membrane ruptures is described. Owing to extreme agitation, the patient was set to a drug‐induced coma for 3 days. After extubation, she experienced simple and complex visual hallucinations for several days, but otherwise recovered largely. Neuropsychological tests revealed deficits in fast visual detection tasks and non‐verbal learning, and indicated a right temporal lobe dysfunction, consistent with a right temporal focus on electroencephalography. Four months after the accident, she developed a psychological reaction consisting of nightmares with reappearance of the complex visual hallucinations and a depressive syndrome. Using the European Cooperation for Lightning Detection network, a meteorological system for lightning surveillance, the exact geographical location and nature of the lightning flash were retrospectively retraced. PMID:17369595

  14. A lightning strike to the head causing a visual cortex defect with simple and complex visual hallucinations

    PubMed Central

    Kleiter, Ingo; Luerding, Ralf; Diendorfer, Gerhard; Rek, Helga; Bogdahn, Ulrich; Schalke, Berthold

    2009-01-01

    The case of a 23-year-old mountaineer who was hit by a lightning strike to the occiput causing a large central visual field defect and bilateral tympanic membrane ruptures is described. Owing to extreme agitation, the patient was sent into a drug-induced coma for 3 days. After extubation, she experienced simple and complex visual hallucinations for several days, but otherwise largely recovered. Neuropsychological tests revealed deficits in fast visual detection tasks and non-verbal learning and indicated a right temporal lobe dysfunction, consistent with a right temporal focus on electroencephalography. At 4 months after the accident, she developed a psychological reaction consisting of nightmares, with reappearance of the complex visual hallucinations and a depressive syndrome. Using the European Cooperation for Lightning Detection network, a meteorological system for lightning surveillance, the exact geographical location and nature of the lightning strike were retrospectively retraced PMID:21734915

  15. Pigmentary glaucoma accompanied by Usher syndrome.

    PubMed

    Koucheki, Behrooz; Jalali, Kamran Hodjat

    2012-08-01

    To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.

  16. Optic nerve lesion following neuroborreliosis: a case report.

    PubMed

    Burkhard, C; Gleichmann, M; Wilhelm, H

    2001-01-01

    Neuroborreliosis may cause various neuro-ophthalmological complications. We describe a case with a bilateral optic neuropathy. A 58-year-old female developed facial paresis six weeks after an insect bite. One week later she developed bilateral optic disc swelling with haemorrhages and nerve fibre bundle defects in the lower visual field of the left eye. In CSF and serum, raised IgM and IgG titres to Borrelia burgdorferi were found. Systemic antibiotic treatment led to improvement of the vision and facial paresis, but not all visual field defects resolved, probably due to ischemic lesions of the optic disc. In optic nerve lesions due to neuroborreliosis it is difficult to distinguish between inflammatory and ischemic lesions. This patient demonstrated features of an ischemic optic nerve lesion.

  17. Development of visual field defect after first-detected optic disc hemorrhage in preperimetric open-angle glaucoma.

    PubMed

    Kim, Hae Jin; Song, Yong Ju; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho

    2017-07-01

    To evaluate functional progression in preperimetric glaucoma (PPG) with disc hemorrhage (DH) and to determine the time interval between the first-detected DH and development of glaucomatous visual field (VF) defect. A total of 87 patients who had been first diagnosed with PPG were enrolled. The medical records of PPG patients without DH (Group 1) and with DH (Group 2) were reviewed. When glaucomatous VF defect appeared, the time interval from the diagnosis of PPG to the development of VF defect was calculated and compared between the two groups. In group 2, the time intervals from the first-detected DH to VF defect of the single- and recurrent-DH were compared. Of the enrolled patients, 45 had DH in the preperimetric stage. The median time interval from the diagnosis of PPG to the development of VF defect was 73.3 months in Group 1, versus 45.4 months in Group 2 (P = 0.042). The cumulative probability of development of VF defect after diagnosis of PPG was significantly greater in Group 2 than in Group 1. The median time interval from first-detected DH to the development of VF defect was 37.8 months. The median time interval from DH to VF defect and cumulative probability of VF defect after DH did not show a statistical difference between single and recurrent-DH patients. The median time interval between the diagnosis of PPG and the development of VF defect was significantly shorter in PPG with DH. The VF defect appeared 37.8 months after the first-detected DH in PPG.

  18. Can Blindsight Be Superior to "Sighted-Sight"?

    ERIC Educational Resources Information Center

    Trevethan, Ceri T.; Sahraie, Arash; Weiskrantz, Larry

    2007-01-01

    DB, the first blindsight case to be tested extensively (Weiskrantz, 1986) has demonstrated the ability to detect and discriminate a range of visual stimuli presented within his perimetrically blind visual field defect. In a temporal two alternative forced choice (2AFC) detection experiment we have investigated the limits of DB's detection ability…

  19. The Advanced Glaucoma Intervention Study (AGIS): 12. Baseline risk factors for sustained loss of visual field and visual acuity in patients with advanced glaucoma.

    PubMed

    2002-10-01

    To examine the relationships between baseline risk factors and sustained decrease of visual field (SDVF) and sustained decrease of visual acuity (SDVA). Cohort study of participants in the Advanced Glaucoma Intervention Study (AGIS). This multicenter study enrolled patients between 1988 and 1992 and followed them until 2001; 789 eyes of 591 patients with advanced glaucoma were randomly assigned to one of two surgical sequences, argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy (ATT) or trabeculectomy-ALT-trabeculectomy (TAT). This report is based on data from 747 eyes. Eyes were offered the next intervention in the sequence upon failure of the previous intervention. Failure was based on recurrent intraocular pressure elevation, visual field defect, and disk rim criteria. Study visits occurred every 6 months; potential follow-up ranged from 8 to 13 years. For each intervention sequence, Cox multiple regression analyses were used to examine the baseline characteristics for association with two vision outcomes: SDVF and SDVA. The magnitude of the association is measured by the hazard ratio (HR), where HR for binary variables is the relative change in the hazard (or risk) of the outcome in eyes with the factor divided by the hazard in eyes without the factor, and HR for continuous variables is the relative change in the hazard (or risk) of the outcome in eyes with a unit increase in the factor. Characteristics associated with increased SDVF risk in the ATT sequence are: less baseline visual field defect (hazard ratio [HR] = 0.86, P <.001, 95% CI = 0.82-0.90), male gender (HR = 2.23, P <.001, 1.54-3.23), and worse baseline visual acuity (HR = 0.96, P =.001, 0.94-0.98); in the TAT sequence: less baseline visual field defect (HR = 0.93, P =.001, 0.89-0.97) and diabetes (HR = 1.87, P =.007, 1.18-2.97). Characteristics associated with increased SDVA risk in both treatment sequences are better baseline acuity (ATT: HR = 1.05, P <.001, 1.02-1.09; TAT: HR = 1.06, P <.001, 1.03-1.08), older age (ATT: HR = 1.05, P =.001, 1.02-1.08; TAT: HR = 1.04, P =.002, 1.01-1.06), and less formal education (ATT: HR = 1.92, P =.001, 1.29-2.88; TAT: HR = 1.77, P =.002, 1.22-2.54). For SDVF, risk factors were better baseline visual field in both treatment sequences, male gender, and worse baseline visual acuity in the ATT sequence, and diabetes in the TAT sequence. For SDVA, risk factors in both treatment sequences were better baseline visual acuity, older age, and less formal education.

  20. Visual field defects after temporal lobe resection for epilepsy.

    PubMed

    Steensberg, Alvilda T; Olsen, Ane Sophie; Litman, Minna; Jespersen, Bo; Kolko, Miriam; Pinborg, Lars H

    2018-01-01

    To determine visual field defects (VFDs) using methods of varying complexity and compare results with subjective symptoms in a population of newly operated temporal lobe epilepsy patients. Forty patients were included in the study. Two patients failed to perform VFD testing. Humphrey Field Analyzer (HFA) perimetry was used as the gold standard test to detect VFDs. All patients performed a web-based visual field test called Damato Multifixation Campimetry Online (DMCO). A bedside confrontation visual field examination ad modum Donders was extracted from the medical records in 27/38 patients. All participants had a consultation by an ophthalmologist. A questionnaire described the subjective complaints. A VFD in the upper quadrant was demonstrated with HFA in 29 (76%) of the 38 patients after surgery. In 27 patients tested ad modum Donders, the sensitivity of detecting a VFD was 13%. Eight patients (21%) had a severe VFD similar to a quadrant anopia, thus, questioning their permission to drive a car. In this group of patients, a VFD was demonstrated in one of five (sensitivity=20%) ad modum Donders and in seven of eight (sensitivity=88%) with DMCO. Subjective symptoms were only reported by 28% of the patients with a VFD and in two of eight (sensitivity=25%) with a severe VFD. Most patients (86%) considered VFD information mandatory. VFD continue to be a frequent adverse event after epilepsy surgery in the medial temporal lobe and may affect the permission to drive a car in at least one in five patients. Subjective symptoms and bedside visual field testing ad modum Donders are not sensitive to detect even a severe VFD. Newly developed web-based visual field test methods appear sensitive to detect a severe VFD but perimetry remains the golden standard for determining if visual standards for driving is fulfilled. Patients consider VFD information as mandatory. Copyright © 2017. Published by Elsevier Ltd.

  1. High-resolution imaging of retinal nerve fiber bundles in glaucoma using adaptive optics scanning laser ophthalmoscopy.

    PubMed

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2013-05-01

    To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.

    PubMed

    Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki

    2014-02-01

    To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.

  3. Representation of the visual field in the striate cortex: comparison of MR findings with visual field deficits in organic mercury poisoning (Minamata disease).

    PubMed

    Korogi, Y; Takahashi, M; Hirai, T; Ikushima, I; Kitajima, M; Sugahara, T; Shigematsu, Y; Okajima, T; Mukuno, K

    1997-01-01

    To compare MR imaging findings of the striate cortex with visual field deficits in patients with Minamata disease and to reestimate the classical Holmes retinotopic map by using the data obtained from comparing visual field abnormalities with degree of visual cortex atrophy. MR imaging was performed in eight patients with Minamata disease who had been given a full neuroophthalmic examination, including Goldmann dynamic perimetry. The atrophic portions of the calcarine area were measured in the sagittal plane next to the midsagittal image and represented as a percentage of atrophy of the total length of the calcarine fissure. MR findings were compared with results of a visual field test. The visual field test revealed moderate to severe concentric constriction of the visual fields, with central vision ranging from 7 degrees to 42 degrees (mean, 19 degrees). The ventral portion of the calcarine sulcus was significantly dilated on MR images in all patients. A logarithmic correlation was found between the visual field defect and the extent of dilatation of the calcarine fissure. The central 10 degrees and 30 degrees of vision seemed to fill about 20% and 50% of the total surface area of the calcarine cortex, respectively. Visual field deficits in patients with Minamata disease correlated well with MR findings of the striate cortex. Our data were consistent with the classical Holmes retinotopic map.

  4. Optic Disc Drusen in Children

    PubMed Central

    Chang, Melinda Y.; Pineles, Stacy L.

    2016-01-01

    Optic disc drusen occur in 0.4% of children and consist of acellular intracellular and extracellular deposits that often become calcified over time. They are typically buried early in life and generally become superficial, and therefore visible, later in childhood, at the average age of 12 years. Their main clinical significance lies in the ability of optic disc drusen, particularly when buried, to simulate true optic disc edema. Misdiagnosing drusen as true disc edema may lead to an invasive and unnecessary workup for elevated intracranial pressure. Ancillary testing, including ultrasonography, fluorescein angiography, fundus autofluorescence, and optical coherence tomography, may aid in the correct diagnosis of optic disc drusen. Complications of optic disc drusen in children include visual field defects, hemorrhages, choroidal neovascular membrane, non-arteritic anterior ischemic optic neuropathy, and retinal vascular occlusions. Treatment options for these complications include ocular hypotensive agents for visual field defects and intravitreal anti-vascular endothelial growth factor (anti-VEGF) agents for choroidal neovascular membranes. In most cases, however, children with optic disc drusen can be managed by observation with serial examinations and visual field testing, once true optic disc edema has been excluded. PMID:27033945

  5. Binocular Glaucomatous Visual Field Loss and Its Impact on Visual Exploration - A Supermarket Study

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as “passed” or “failed” with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p<0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p<0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a “time-effective” compensatory mechanism during the present supermarket task. PMID:25162522

  6. Binocular glaucomatous visual field loss and its impact on visual exploration--a supermarket study.

    PubMed

    Sippel, Katrin; Kasneci, Enkelejda; Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as "passed" or "failed" with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p < 0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p < 0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a "time-effective" compensatory mechanism during the present supermarket task.

  7. Stage II Chronic Maxillary Atelectasis Associated with Subclinical Visual Field Defect.

    PubMed

    Mangussi-Gomes, João; Nakanishi, Márcio; Chalita, Maria Regina; Damasco, Fabiana; De Oliveira, Carlos Augusto Costa Pires

    2013-10-01

    Introduction Chronic maxillary atelectasis (CMA) is characterized by a persistent decrease in the maxillary sinus volume due to inward bowing of its walls. According to its severity, it may be classified into three clinical-radiological stages. Objective To report a case of stage II CMA associated with subclinical visual field defect. Case Report A 34-year-old woman presented with a 15-year history of recurrent episodes of sinusitis and intermittent right facial discomfort for the past 5 years. She denied visual complaints, and no facial deformities were observed on physical examination. Paranasal sinus computed tomography (CT) demonstrated a completely opacified right maxillary sinus with inward bowing of its walls, suggesting the diagnosis of stage II CMA. A computerized campimetry (CC) disclosed a scotoma adjacent to the blind spot of the right eye, indicating a possible damage to the optic nerve. The patient was submitted to functional endoscopic sinus surgery, with drainage of a thick mucous fluid from the sinus. She did well after surgery and has been asymptomatic since then. Postoperative CT was satisfactory and CC was normal. Discussion CMA occurs because of a persistent ostiomeatal obstruction, which creates negative pressure inside the sinus. It is associated with nasosinusal symptoms but had never been described in association with any visual field defect. It can be divided into stage I (membranous deformity), stage II (bony deformity), and stage III (clinical deformity). The silent sinus syndrome is a special form of CMA. This term should only be used to describe those cases with spontaneous enophthalmos, hypoglobus, and/or midfacial deformity in the absence of nasosinusal symptoms.

  8. Evaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes

    PubMed Central

    Hong, Samin; Moon, Jong Wook; Ha, Seung Joo; Kim, Chan Yun; Seong, Gong Je

    2007-01-01

    Purpose To evaluate retinal nerve fiber layer (RNFL) defect by a new scoring system for RNFL photography using the Heidelberg Retina Angiograph 1 (HRA1). Methods This retrospective study included 128 healthy eyes and 836 primary open-angle glaucoma eyes. The RNFL photography using HRA1 was interpreted using a new scoring system, and correlated with visual field indices of standard automated perimetry (SAP). Using the presence of RNFL defect, darkness, width, and location, we established the new scoring system of RNFL photos. Results The mean RNFL defect score I in the early, moderate, severe, and control groups were 7.3, 9.2, 10.4, and 3.6, respectively. The mean RNFL defect score II in the early, moderate, severe, and control groups were 14.5, 28.5, 43.4, and 3.4, respectively. Correlations between the RNFL defect score II and the mean deviation of SAP was the strongest of the various combinations (r=-0.675, P<.001). Conclusions Using a new scoring system, we propose a method for semi-quantitative interpretation of RNFL photographs. This scoring system may be helpful to distinguish between normal and glaucomatous eyes, and the score is associated with the severity of visual field loss. PMID:18063886

  9. Branch retinal arterial occlusion.

    PubMed

    Subedi, S; Shrestha, C

    2010-01-01

    Retinal arterial occlusion is an ocular emergency in which visual prognosis is poor mostly due to late presentation of the patient and macular involvement. The casee described, in this report is ane incidence of Branch Retinal Arterial Occlusion in a 22 year old female with grade II Mitral Regurgitation. The patiente presented witha complaint of painless, diminution of vision in the right eyn. She also presented with perception of black shadow in the superior visual fiel n of the same eye5 for five days. There was no significant systemic ord personal history. Her visual acuity at presentation was 6/60 and 6/6 in the right and left eyes,y which did not improve with glasses or pin-hole. Anterior segment including papillary reaction was normal in both eyes while Fundus examination of the right eye revealed retinal whitening inside the inferotemporal vascular arcade that was encroaching foveolar avascular zone. Visual field defect was detected at superonasally inside arhade but Fundus Fluorescence Angiography was normal. An echoycardiograph revealed grade II Mitral Regurgitation. The patient was kept on observation and after two2 days of follow-up, vision in the right eye was improved to 6/6 unaided but visual field defect was remained same.

  10. Ethambutol/Linezolid Toxic Optic Neuropathy.

    PubMed

    Libershteyn, Yevgeniya

    2016-02-01

    To report a rare toxic optic neuropathy after long-term use of two medications: ethambutol and linezolid. A 65-year-old man presented to the Miami Veterans Affairs Medical Center in December 2014 for evaluation of progressive vision decrease in both eyes. The patient presented with best-corrected visual acuities of 20/400 in the right eye and counting fingers at 5 feet in the left eye. Color vision was significantly reduced in both eyes. Visual fields revealed a cecocentral defect in both eyes. His fundus and optic nerve examination was unremarkable. Because vision continued to decline after discontinuation of ethambutol, linezolid was also discontinued, after which vision, color vision, and visual fields improved. Because of these findings, the final diagnosis was toxic optic neuropathy. Final visual outcome was 20/30 in the right eye and 20/40 in the left eye. Drug-associated toxic optic neuropathy is a rare but vision-threatening condition. Diagnosis is made based on an extensive case history and careful clinical examination. The examination findings include varying decrease in vision, normal pupils and extraocular muscles, and unremarkable fundoscopy, with the possibility of swollen optic discs in the acute stage of the optic neuropathy. Other important findings descriptive of toxic optic neuropathy include decreased color vision and cecocentral visual field defects. This case illustrates the importance of knowledge of all medications and/or substances a patient consumes that may cause a toxic reaction and discontinuing them immediately if the visual functions are worsening or not improving.

  11. 41 CFR 51-1.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... whose visual acuity, if better than 20/200, is accompanied by a limit to the field of vision in the... congenital defect) which so limits the person's functional capabilities (mobility, communication, self-care...

  12. Presumed topiramate retinopathy: a case report.

    PubMed

    Yeung, Tiffany L M; Li, Patrick S H; Li, Kenneth K W

    2016-08-01

    We report a case of peripheral pigmentary retinopathy and visual field loss following topiramate use for uncontrolled seizures. Such side effects have not been well documented despite the increasing use of topiramate in the past 10 years. A thorough search of available English literature revealed only a small number of reports of topiramate-induced retinopathy or visual field defects in humans. One similar case has been described. We are concerned about the possible rare instances of this occurrence in future patients and hence would like to propose a presumed correlation. A 48-year-old Chinese woman developed blurred vision after 9 months of topiramate use. Her visual acuity dropped from 1.2 to 0.7 in both eyes, with bilateral diffuse pigmentary retinopathy and a constricted visual field. Despite an improvement in visual acuity after cessation of the drug, the other clinical findings remained. The temporal relationship between the initiation of topiramate and the visual disturbance suggests that topiramate could be the cause of such signs and symptoms. Topiramate potentially causes pigmentary retinopathy and constricted visual field.

  13. The Effects of Compensatory Scanning Training on Mobility in Patients with Homonymous Visual Field Defects: Further Support, Predictive Variables and Follow-Up

    PubMed Central

    Melis-Dankers, Bart J. M.; Brouwer, Wiebo H.; Tucha, Oliver; Heutink, Joost

    2016-01-01

    Introduction People with homonymous visual field defects (HVFD) often report difficulty detecting obstacles in the periphery on their blind side in time when moving around. Recently, a randomized controlled trial showed that the InSight-Hemianopia Compensatory Scanning Training (IH-CST) specifically improved detection of peripheral stimuli and avoiding obstacles when moving around, especially in dual task situations. Method The within-group training effects of the previously reported IH-CST are examined in an extended patient group. Performance of patients with HVFD on a pre-assessment, post-assessment and follow-up assessment and performance of a healthy control group are compared. Furthermore, it is examined whether training effects can be predicted by demographic characteristics, variables related to the visual disorder, and neuropsychological test results. Results Performance on both subjective and objective measures of mobility-related scanning was improved after training, while no evidence was found for improvement in visual functions (including visual fields), reading, visual search and dot counting. Self-reported improvement did not correlate with improvement in objective mobility performance. According to the participants, the positive effects were still present six to ten months after training. No demographic characteristics, variables related to the visual disorder, and neuropsychological test results were found to predict the size of training effect, although some inconclusive evidence was found for more improvement in patients with left-sided HVFD than in patients with right-sided HFVD. Conclusion Further support was found for a positive effect of IH-CST on detection of visual stimuli during mobility-related activities specifically. Based on the reports given by patients, these effects appear to be long-term effects. However, no conclusions can be drawn on the objective long-term training effects. PMID:27935973

  14. A novel visual pipework inspection system

    NASA Astrophysics Data System (ADS)

    Summan, Rahul; Jackson, William; Dobie, Gordon; MacLeod, Charles; Mineo, Carmelo; West, Graeme; Offin, Douglas; Bolton, Gary; Marshall, Stephen; Lille, Alexandre

    2018-04-01

    The interior visual inspection of pipelines in the nuclear industry is a safety critical activity conducted during outages to ensure the continued safe and reliable operation of plant. Typically, the video output by a manually deployed probe is viewed by an operator looking to identify and localize surface defects such as corrosion, erosion and pitting. However, it is very challenging to estimate the nature and extent of defects by viewing a large structure through a relatively small field of view. This work describes a new visual inspection system employing photogrammetry using a fisheye camera and a structured light system to map the internal geometry of pipelines by generating a photorealistic, geometrically accurate surface model. The error of the system output was evaluated through comparison to a ground truth laser scan (ATOS GOM Triple Scan) of a nuclear grade split pipe sample (stainless steel 304L, 80mm internal diameter) containing defects representative of the application - the error was found to be submillimeter across the sample.

  15. Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma.

    PubMed

    Kothari, Ruchi; Bokariya, Pradeep; Singh, Ramji; Singh, Smita; Narang, Purvasha

    2014-01-01

    To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation (PSD) of Humphrey visual field could be associated with visual evoked potential (VEP) parameters of patients having primary open angle glaucoma (POAG). Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential (PRVEP) were assessed in 100 patients with POAG. The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated (full field) and displayed on VEP monitor (colour 14″) by an electronic pattern regenerator inbuilt in an evoked potential recorder (RMS EMG EP MARK II). The results of our study indicate that there is a highly significant (P<0.001) negative correlation of P100 amplitude and a statistically significant (P<0.05) positive correlation of N70 latency, P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student's t-test. Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values. Conversely, as PSD increases the magnitude of VEP excursions were found to be diminished.

  16. Development of PZT-excited stroboscopic shearography for full-field nondestructive evaluation.

    PubMed

    Asemani, Hamidreza; Park, Jinwoo; Lee, Jung-Ryul; Soltani, Nasser

    2017-05-01

    Nondestructive evaluation using shearography requires a way to stress the inspection target. This technique is able to directly measure the displacement gradient distribution on the object surface. Shearography visualizes the internal structural damages as the anomalous pattern in the shearograpic fringe pattern. A piezoelectric (PZT) excitation system is able to generate loadings in the vibrational, acoustic, and ultrasonic regimes. In this paper, we propose a PZT-excited stroboscopic shearography. The PZT excitation could generate vibrational loading, a stationary wavefield, and a nonstationary propagation wave to fulfill the external loading requirement of shearography. The sweeping of the PZT excitation frequency, the formation of a standing wave, and a small shearing to suppress the incident wave were powerful controllable tools to detect the defects. The sweeping of the PZT excitation frequency enabled us to determine one of the defect-sensitive frequencies almost in real time. In addition, because the defect sensitive frequencies always existed in wide and plural ranges, the risk of the defect being overlooked by the inspector could be alleviated. The results of evaluation using stroboscopic shearography showed that an artificial 20 mm-diameter defect could be visualized at the excitation frequencies of 5-8 kHz range and 12.5-15.5 kHz range. This technique provided full field reliable and repeatable inspection results. Additionally, the proposed method overcame the important drawback of the time-averaged shearography, being required to identify the resonance vibration frequency sensitive to the defect.

  17. Walking simulator for evaluation of ophthalmic devices

    NASA Astrophysics Data System (ADS)

    Barabas, James; Woods, Russell L.; Peli, Eli

    2005-03-01

    Simulating mobility tasks in a virtual environment reduces risk for research subjects, and allows for improved experimental control and measurement. We are currently using a simulated shopping mall environment (where subjects walk on a treadmill in front of a large projected video display) to evaluate a number of ophthalmic devices developed at the Schepens Eye Research Institute for people with vision impairment, particularly visual field defects. We have conducted experiments to study subject's perception of "safe passing distance" when walking towards stationary obstacles. The subject's binary responses about potential collisions are analyzed by fitting a psychometric function, which gives an estimate of the subject's perceived safe passing distance, and the variability of subject responses. The system also enables simulations of visual field defects using head and eye tracking, enabling better understanding of the impact of visual field loss. Technical infrastructure for our simulated walking environment includes a custom eye and head tracking system, a gait feedback system to adjust treadmill speed, and a handheld 3-D pointing device. Images are generated by a graphics workstation, which contains a model with photographs of storefronts from an actual shopping mall, where concurrent validation experiments are being conducted.

  18. Multifocal blue-on-yellow visual evoked potentials in early glaucoma.

    PubMed

    Klistorner, Alexander; Graham, Stuart L; Martins, Alessandra; Grigg, John R; Arvind, Hemamalini; Kumar, Rajesh S; James, Andrew C; Billson, Francis A

    2007-09-01

    To determine the sensitivity and specificity of blue-on-yellow multifocal visual evoked potentials (mfVEPs) in early glaucoma. Cross-sectional study. Fifty patients with a confirmed diagnosis of early glaucoma and 60 normal participants. Black-and-white mfVEPs and blue-on-yellow mfVEPs were recorded using the Accumap version 2.0 (ObjectiVision Pty. Ltd., Sydney, Australia). All patients also underwent achromatic standard automated perimetry (SAP). Multifocal VEP amplitude and latency values in glaucoma patients were analyzed and compared with those of the normal controls. Based on the definition of visual field defect, in the group of glaucomatous eyes with SAP defects, amplitude of blue-on-yellow mfVEP was abnormal in all 64 cases (100% sensitivity), whereas black-and-white mfVEP missed 5 cases (92.2% sensitivity). Generally, larger scotomata were noted on blue-on-yellow mfVEP compared with black-and-white mfVEP for the same eyes. There was high topographic correspondence between SAP and amplitude of blue-on-yellow mfVEP and significant (P<0.0001) correlation between them (correlation coefficient, 0.73). Abnormal amplitude was detected in 3 of 60 eyes of control subjects (95% specificity). There was, however, no correlation between visual field defect and latency delay in glaucoma patients. Although there was a significant difference between averaged latency of control and glaucoma eyes, values considerably overlapped. The blue-on-yellow mfVEP is a sensitive and specific tool for detecting early glaucoma based on amplitude analysis.

  19. A pediatric case of pituitary macroadenoma presenting with pituitary apoplexy and cranial nerve involvement: case report

    PubMed Central

    Özçetin, Mustafa; Karacı, Mehmet; Toroslu, Ertuğ; Edebali, Nurullah

    2016-01-01

    Pituitary adenomas usually arise from the anterior lobe of the pituitary gland and are manifested with hormonal disorders or mass effect. Mass effect usually occurs in nonfunctional tumors. Pituitary adenomas may be manifested with visual field defects or rarely in the form of total oculomotor palsy. Visual field defect is most frequently in the form of bitemporal hemianopsia and superior temporal defect. Sudden loss of vision, papilledema and ophthalmoplegia may be observed. Pituitary apoplexy is defined as an acute clinical syndrome characterized with headache, vomiting, loss of vision, ophthalmoplegia and clouding of consciousness. The problem leading to pituitary apoplexy may be decreased blood supply in the adenoma and hemorrhage following this decrease or hemorrhage alone. In this article, we present a patient who presented with fever, vomiting and sudden loss of vision and limited outward gaze in the left eye following trauma and who was found to have pituitary macroadenoma causing compression of the optic chiasma and optic nerve on the left side on cranial and pituitary magnetic resonance imaging. PMID:27738402

  20. Adalimumab and Non-Arteritic Anterior Ischaemic Optic Neuropathy: A Case Report.

    PubMed

    Kinard, Krista; Walsh, Jessica A; Penmetsa, Gopi K; Warner, Judith E A

    2014-01-01

    Sequential anterior ischaemic optic neuropathy was observed in a patient treated with a tumour necrosis factor α (TNF) inhibitor, adalimumab, for ankylosing spondylitis. He developed decreased visual acuity in the right eye after 17 months of treatment. Findings showed right optic disc oedema with haemorrhages and visual field defect. Adalimumab was discontinued and vision stabilised. After restarting adalimumab, he developed optic neuropathy in the left eye. Findings showed optic disc oedema, with haemorrhages and visual field changes in the left eye. Adalimumab may be associated with optic neuropathy; providers prescribing TNF inhibitors should be aware of optic neuropathy as a potential complication.

  1. Visual field impairment captures disease burden in multiple sclerosis.

    PubMed

    Ortiz-Perez, Santiago; Andorra, Magí; Sanchez-Dalmau, Bernardo; Torres-Torres, Rubén; Calbet, David; Lampert, Erika J; Alba-Arbalat, Salut; Guerrero-Zamora, Ana M; Zubizarreta, Irati; Sola-Valls, Nuria; Llufriu, Sara; Sepúlveda, María; Saiz, Albert; Villoslada, Pablo; Martinez-Lapiscina, Elena H

    2016-04-01

    Monitoring disease burden is an unmeet need in multiple sclerosis (MS). Identifying patients at high risk of disability progression will be useful for improving clinical-therapeutic decisions in clinical routine. To evaluate the role of visual field testing in non-optic neuritis eyes (non-ON eyes) as a biomarker of disability progression in MS. In 109 patients of the MS-VisualPath cohort, we evaluated the association between visual field abnormalities and global and cognitive disability markers and brain and retinal imaging markers of neuroaxonal injury using linear regression models adjusted for sex, age, disease duration and use of disease-modifying therapies. We evaluated the risk of disability progression associated to have baseline impaired visual field after 3 years of follow-up. Sixty-two percent of patients showed visual field defects in non-ON eyes. Visual field mean deviation was statistically associated with global disability; brain (normalized brain parenchymal, gray matter volume and lesion load) and retinal (peripapillary retinal nerve fiber layer thickness and macular ganglion cell complex thickness) markers of neuroaxonal damage. Patients with impaired visual field had statistically significative greater disability, lower normalized brain parenchymal volume and higher lesion volume than patients with normal visual field testing. MS patients with baseline impaired VF tripled the risk of disability progression during follow-up [OR = 3.35; 95 % CI (1.10-10.19); p = 0.033]. The association of visual field impairment with greater disability and neuroaxonal injury and higher risk of disability progression suggest that VF could be used to monitor MS disease burden.

  2. The Advanced Glaucoma Intervention Study (AGIS): 14. Distinguishing progression of glaucoma from visual field fluctuations.

    PubMed

    Kim, Jonghyeon; Dally, Leonard G; Ederer, Fred; Gaasterland, Douglas E; VanVeldhuisen, Paul C; Blackwell, Beth; Sullivan, E Kenneth; Prum, Bruce; Shafranov, George; Beck, Allen; Spaeth, George L

    2004-11-01

    To determine the least worsening of a visual field (VF) and the least number of confirming tests needed to identify progression of glaucomatous VF defects. Cohort study of participants in a clinical trial. Seven hundred fifty-two eyes of 565 patients with advanced glaucoma. Visual field tests were quantified with the Advanced Glaucoma Intervention Study (AGIS) VF defect score and the Humphrey Field Analyzer mean deviation (MD). Follow-up was 8 to 13 years. Two measures based on the AGIS VF defect score: (1) sustained decrease of VF (SDVF), a worsening from baseline by 2 (alternatively, 3 or 4) or more units and sustained for 2 (alternatively, 3) consecutive 6-month visits and (2) after the occurrence of SDVF, the average percent of eyes with worsening by 2 (alternatively, 3 or 4) or more units from baseline. Two similar measures based on MD. Based on the original AGIS criteria for SDVF (a worsening of 4 units in the AGIS score sustained during 3 consecutive 6-month visits), 31% of eyes had an SDVF. The percent of eyes with a sustained event increases by approximately 10% when either the minimum number of units of field loss or the minimum number of 6-month visits during which the loss is sustained decreases by 1. During 3 years of follow-up after a sustained event, a worsening of at least 2 units was found in 72% of eyes that had a 2-visit sustained event. The same worsening was found in 84% of eyes that had a 3-visit sustained event. Through the next 10 years after a sustained event, based on worsening of 2, 3, or 4 units at 2 or 3 consecutive tests, the loss reoccurred, on average, in >/=75% of study eyes. Results for MD are similar. In patients with advanced glaucoma, a single confirmatory test 6 months after a VF worsening indicates with at least 72% probability a persistent defect when the worsening is defined by at least 2 units of AGIS score or by at least 2 decibels of MD. When the number of confirmatory tests is increased from 1 to 2, the percentage of eyes that show a persistent defect increases from 72% to 84%.

  3. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    PubMed

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  4. Optic neuropathy causing vertical unilateral hemianopsia after pars plana vitrectomy for a macular hole: A case report.

    PubMed

    Kawashima, Hirohiko; Nagai, Norihiro; Shinoda, Hajime; Tsubota, Kazuo; Ozawa, Yoko

    2018-04-01

    Recent progress in medical technology has resulted in improved surgical outcomes of pars plana vitrectomy (PPV); with microincision systems, the incidence of procedure-related complications during surgery has been reduced. However, unpredictable visual field defects after PPV remain an unresolved issue. A few reports have shown that damage to the retinal neurofibers owing to dry-up during air/fluid exchange or retinal neurotoxicity of the dye used to visualize the internal limiting membrane (ILM), as well as unintentional removal of retinal neurofibers during ILM peeling, are responsible for such visual field disorders. In this report, we present a case of extensive visual field defect due to optic neuropathy exhibiting vertical hemianopsia after PPV. A 50-year-old woman underwent PPV and cataract surgery for a macular hole and mild cataract under retrobulbar anesthesia with 3.5 mL of xylocaine. At the time of opening an infusion cannula for PPV, the intraocular lens was herniating, with an acute increase in pressure from the posterior eyeball; thus, intraocular pressure configuration level had to be decreased from the default level, whereas the other procedures including 20% SF6 injection were performed without any modification. The macular hole was closed postoperatively. However, the patient experienced nasal hemianopsia, which turned out to be optic neuropathy, as assessed via electric physiological examinations. The pattern of the visual field defect was not typical for glaucoma or anterior ischemic optic neuropathy. Her optic nerve head was pale at the temporal side soon after the surgery, and her blood pressure was low, suggesting that there may have been a congestion of the optic nerve feeder vessels because of the relatively high pressure in the orbit. The space occupancy with xylocaine and extensively stretched and plumped out eye ball with infusion during PPV may have pressed the surrounding tissue of the optic nerve and the feeder vessels. PPV is safe for most patients; however, individual variations in local and/or systemic conditions may cause complications. Future studies to optimize the surgical condition for each individual patient may be warranted.

  5. Clinical Verification of Image Warping as a Potential Aid for the Visually Handicapped

    NASA Technical Reports Server (NTRS)

    Loshin, David

    1996-01-01

    The bulk of this research was to designed determine potential of the Programmable Remapper (PR) as a device to enhance vision for the visually handicapped. This research indicated that remapping would have potential as a low vision device if the eye position could be monitored with feedback to specify the proper location of the remapped image. This must be accomplished at high rate so that there is no lag of the image behind the eye position. Since at this time, there is no portable eye monitor device (at a reasonable cost) that will operate under the required conditions, it would not be feasible to continue with remapping experiments for patients with central field defects. However, since patients with peripheral field defects do not have the same eye positioning requirements, they may indeed benefit from this technology. Further investigations must be performed to determine plausibility of this application of remapping.

  6. Extent of resection in temporal lobectomy for epilepsy. II. Memory changes and neurologic complications.

    PubMed

    Katz, A; Awad, I A; Kong, A K; Chelune, G J; Naugle, R I; Wyllie, E; Beauchamp, G; Lüders, H

    1989-01-01

    We present correlations of extent of temporal lobectomy for intractable epilepsy with postoperative memory changes (20 cases) and abnormalities of visual field and neurologic examination (45 cases). Postoperative magnetic resonance imaging (MRI) in the coronal plane was used to quantify anteroposterior extent of resection of various quadrants of the temporal lobe, using a 20-compartment model of that structure. The Wechsler Memory Scale-Revised (WMS-R) was administered preoperatively and postoperatively. Postoperative decrease in percentage of retention of verbal material correlated with extent of medial resection of left temporal lobe, whereas decrease in percentage of retention of visual material correlated with extent of medial resection of right temporal lobe. These correlations approached but did not reach statistical significance. Extent of resection correlated significantly with the presence of visual field defect on perimetry testing but not with severity, denseness, or congruity of the defect. There was no correlation between postoperative dysphasia and extent of resection in any quadrant. Assessment of extent of resection after temporal lobectomy allows a rational interpretation of postoperative neurologic deficits in light of functional anatomy of the temporal lobe.

  7. Comprehensive visual field test & diagnosis system in support of astronaut health and performance

    NASA Astrophysics Data System (ADS)

    Fink, Wolfgang; Clark, Jonathan B.; Reisman, Garrett E.; Tarbell, Mark A.

    Long duration spaceflight, permanent human presence on the Moon, and future human missions to Mars will require autonomous medical care to address both expected and unexpected risks. An integrated non-invasive visual field test & diagnosis system is presented for the identification, characterization, and automated classification of visual field defects caused by the spaceflight environment. This system will support the onboard medical provider and astronauts on space missions with an innovative, non-invasive, accurate, sensitive, and fast visual field test. It includes a database for examination data, and a software package for automated visual field analysis and diagnosis. The system will be used to detect and diagnose conditions affecting the visual field, while in space and on Earth, permitting the timely application of therapeutic countermeasures before astronaut health or performance are impaired. State-of-the-art perimetry devices are bulky, thereby precluding application in a spaceflight setting. In contrast, the visual field test & diagnosis system requires only a touchscreen-equipped computer or touchpad device, which may already be in use for other purposes (i.e., no additional payload), and custom software. The system has application in routine astronaut assessment (Clinical Status Exam), pre-, in-, and post-flight monitoring, and astronaut selection. It is deployable in operational space environments, such as aboard the International Space Station or during future missions to or permanent presence on the Moon and Mars.

  8. Projected impact of travoprost versus both timolol and latanoprost on visual field deficit progression and costs among black glaucoma subjects.

    PubMed Central

    Halpern, Michael T; Covert, David W; Robin, Alan L

    2002-01-01

    PURPOSE: We compared differences associated with use of travoprost and latanoprost on both progression of perimetric loss over time and associated costs among black patients. METHODS: Patients with primary open-angle glaucome or ocular hypertension were randomly assigned to one of four arms in a 12-month, double-masked study: travoprost (0.004% or 0.0015%), latanoprost (0.005%), or timolol (0.5%). Forty-nine patients received 0.004% travoprost, 43 received latanoprost, and 40 received timolol. We applied algorithms found in published studies that link intraocular pressure (IOP) control to visual field progression and calculated the likelihood of visual field deterioration based on IOP data. This was used to estimate differences in medical care costs. RESULTS: The average IOP was lower for patients receiving travoprost than for patients receiving latanoprost or timolol (17.3 versus 18.7 versus 20.5 mm Hg respectively, P < .05). Travoprost-treated patients had a smaller predicted change in visual field defect score (VFDS) than latanoprost-treated patients and timolol-treated patients, and significantly fewer were expected to demonstrate visual field progression. Medical care costs would be higher for latanoprost-treated and timolol-treated patients. CONCLUSIONS: Recent studies have provided algorithms linking IOP control to changes in visual fields. We found that treatment with travoprost was associated with less visual field progression and potential cost savings. PMID:12545683

  9. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  10. Deep Defects Seen on Visual Fields Spatially Correspond Well to Loss of Retinal Nerve Fiber Layer Seen on Circumpapillary OCT Scans.

    PubMed

    Mavrommatis, Maria A; Wu, Zhichao; Naegele, Saskia I; Nunez, Jason; De Moraes, Carlos; Ritch, Robert; Hood, Donald C

    2018-02-01

    To examine the structure-function relationship in glaucoma between deep defects on visual fields (VF) and deep losses in the circumpapillary retinal nerve fiber layer (cpRNFL) on optical coherence tomography (OCT) circle scans. Thirty two glaucomatous eyes with deep VF defects, as defined by at least one test location worse than ≤ -15 dB on the 10-2 and/or 24-2 VF pattern deviation (PD) plots, were included from 87 eyes with "early" glaucoma (i.e., 24-2 mean deviation better than -6 dB). Using the location of the deep VF points and a schematic model, the location of local damage on an OCT circle scan was predicted. The thinnest location of cpRNFL (i.e., deepest loss) was also determined. In 19 of 32 eyes, a region of complete or near complete cpRNFL loss was observed. All 19 of these had deep VF defects on the 24-2 and/or 10-2. All of the 32 eyes with deep VF defects had abnormal cpRNFL regions (red, 1%) and all but 2 had a region of cpRNFL thickness <21 μm. The midpoint of the VF defect and the location of deepest cpRNFL had a 95% limit of agreement within approximately two-thirds of a clock-hour (or 30°) sector (between -22.1° to 25.2°). Individual fovea-to-disc angle (FtoDa) adjustment improved agreement in one eye with an extreme FtoDa. Although studies relating local structural (OCT) and functional (VF) measures typically show poor to moderate correlations, there is good qualitative agreement between the location of deep cpRNFL loss and deep defects on VFs.

  11. Combined Transcranial Direct Current Stimulation and Vision Restoration Training in Subacute Stroke Rehabilitation: A Pilot Study.

    PubMed

    Alber, Raimund; Moser, Hermann; Gall, Carolin; Sabel, Bernhard A

    2017-08-01

    Visual field defects after posterior cerebral artery stroke can be improved by vision restoration training (VRT), but when combined with transcranial direct current stimulation (tDCS), which alters brain excitability, vision recovery can be potentiated in the chronic stage. To date, the combination of VRT and tDCS has not been evaluated in postacute stroke rehabilitation. To determine whether combined tDCS and VRT can be effectively implemented in the early recovery phase following stroke, and to explore the feasibility, safety and efficacy of an early intervention. Open-label pilot study including a case series of 7 tDCS/VRT versus a convenience sample of 7 control patients (ClinicalTrials.gov ID: NCT02935413). Rehabilitation center. Patients with homonymous visual field defects following a posterior cerebral artery stroke. Seven homonymous hemianopia patients were prospectively treated with 10 sessions of combined tDCS (2.mA, 10 daily sessions of 20 minutes) and VRT at 66 (±50) days on average poststroke. Visual field recovery was compared with the retrospective data of 7 controls, whose defect sizes and age of lesions were matched to those of the experimental subjects and who had received standard rehabilitation with compensatory eye movement and exploration training. All 7 patients in the treatment group completed the treatment protocol. The safety and acceptance were excellent, and patients reported occasional skin itching beneath the electrodes as the only minor side effect. Irrespective of their treatment, both groups (treatment and control) showed improved visual fields as documented by an increased mean sensitivity threshold in decibels in standard static perimetry. Recovery was significantly greater (P < .05) in the tDCS/VRT patients (36.73% ± 37.0%) than in the controls (10.74% ± 8.86%). In this open-label pilot study, tDCS/VRT in subacute stroke was demonstrated to be safe, with excellent applicability and acceptance of the treatment. Preliminary effectiveness calculations show that tDCS/VRT may be superior to standard vision training procedures. A confirmatory, larger-sample, controlled, randomized, and double-blind trial is now underway to compare real-tDCS- versus sham-tDCS-supported visual field training in the early vision rehabilitation phase. IV. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  12. Recognizing patterns of visual field loss using unsupervised machine learning

    NASA Astrophysics Data System (ADS)

    Yousefi, Siamak; Goldbaum, Michael H.; Zangwill, Linda M.; Medeiros, Felipe A.; Bowd, Christopher

    2014-03-01

    Glaucoma is a potentially blinding optic neuropathy that results in a decrease in visual sensitivity. Visual field abnormalities (decreased visual sensitivity on psychophysical tests) are the primary means of glaucoma diagnosis. One form of visual field testing is Frequency Doubling Technology (FDT) that tests sensitivity at 52 points within the visual field. Like other psychophysical tests used in clinical practice, FDT results yield specific patterns of defect indicative of the disease. We used Gaussian Mixture Model with Expectation Maximization (GEM), (EM is used to estimate the model parameters) to automatically separate FDT data into clusters of normal and abnormal eyes. Principal component analysis (PCA) was used to decompose each cluster into different axes (patterns). FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal (i.e., glaucomatous) FDT results, recruited from a university-based, longitudinal, multi-center, clinical study on glaucoma. The GEM input was the 52-point FDT threshold sensitivities for all eyes. The optimal GEM model separated the FDT fields into 3 clusters. Cluster 1 contained 94% normal fields (94% specificity) and clusters 2 and 3 combined, contained 77% abnormal fields (77% sensitivity). For clusters 1, 2 and 3 the optimal number of PCA-identified axes were 2, 2 and 5, respectively. GEM with PCA successfully separated FDT fields from healthy and glaucoma eyes and identified familiar glaucomatous patterns of loss.

  13. Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes.

    PubMed

    Hu, Rongrong; Wang, Chenkun; Racette, Lyne

    2017-01-01

    Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. All eyes had glaucomatous optic neuropathy or ocular hypertension, but normal SAP and FDT results at baseline. The development of glaucomatous VF defects was defined as the presence of a cluster of ≥ 3 (less conservative) or ≥ 4 (more conservative) locations confirmed on ≥ 2 additional consecutive tests. Risk factors for the development of VF defects were analyzed by COX proportional hazard models. After conversion into common logarithmic units, the rates of change of global VF indices were fitted with linear mixed models. FDT detected more eyes that developed VF defects than SAP using the less conservative criterion, and no significant difference was observed using the more conservative criterion. For those eyes detected by both SAP and FDT, FDT detected the development of VF defects either earlier than SAP or simultaneously in most cases. Baseline structural measurements were not significantly associated with an increased risk for the development of glaucomatous VF defects on either SAP or FDT. Older age was significantly associated with the development of VF defects on FDT but not on SAP. Both SAP and FDT detected a progressing worsening trend of pattern standard deviation over time with a similar rate of change between these test types. Matrix FDT would be useful to monitor the onset of VF defects in glaucoma suspects and may outperform SAP in the early stage of glaucomatous VF damage.

  14. [Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT].

    PubMed

    Poli, M; Colange, J; Goutagny, B; Sellem, E

    2017-09-01

    Optic nerve head drusen are congenital calcium deposits located in the prelaminar section of the optic nerve head. Their association with visual field defects has been classically described, but the diagnosis of glaucoma is not easy in these cases of altered optic nerve head anatomy. We describe the case of a 67-year-old man with optic nerve head drusen complicated by glaucoma, which was confirmed by visual field and OCT examination of the peripapillary retinal nerve fiber layer (RNFL), but the measurement of the minimum distance between the Bruch membrane opening and the internal limiting membrane (minimum rim width, BMO-MRW) by OCT was normal. OCT of the BMO-MRW is a new diagnostic tool for glaucoma. Superficial optic nerve head drusen, which are found between the internal limiting membrane and the Bruch's membrane opening, overestimate the value of this parameter. BMO-MRW measurement is not adapted to cases of optic nerve head drusen and can cause false-negative results for this parameter, and the diagnosis of glaucoma in this case should be based on other parameters such as the presence of a fascicular defect in the retinal nerve fibers, RNFL or macular ganglion cell complex thinning, as well as visual field data. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Correlation of Retinal Nerve Fiber Layer Thickness and Visual Fields in Glaucoma: A broken stick model

    PubMed Central

    Alasil, Tarek; Wang, Kaidi; Yu, Fei; Field, Matthew G.; Lee, Hang; Baniasadi, Neda; de Boer, Johannes F.; Coleman, Anne L.; Chen, Teresa C.

    2015-01-01

    Purpose To determine the retinal nerve fiber layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss. Design Retrospective cross-sectional study. Methods Eighty seven healthy and 108 glaucoma subjects (one eye per subject) were recruited from an academic institution. All patients had VF examinations (Swedish Interactive Threshold Algorithm 24-2 test of the Humphrey visual field analyzer 750i; Carl Zeiss Meditec, Dublin, CA) and spectral domain optical coherence tomography RNFL scans (Spectralis, Heidelberg Engineering, Heidelberg, Germany). Comparison of RNFL thicknesses values with VF threshold values showed a plateau of VF threshold values at high RNFL thickness values and then a sharp decrease at lower RNFL thickness values. A broken stick statistical analysis was utilized to estimate the tipping point at which RNFL thickness values are associated with VF defects. The slope for the association between structure and function was computed for data above and below the tipping point. Results The mean RNFL thickness value that was associated with initial VF loss was 89 μm. The superior RNFL thickness value that was associated with initial corresponding inferior VF loss was 100 μm. The inferior RNFL thickness value that was associated with initial corresponding superior VF loss was 73 μm. The differences between all the slopes above and below the aforementioned tipping points were statistically significant (p<0.001). Conclusions In open angle glaucoma, substantial RNFL thinning or structural loss appears to be necessary before functional visual field defects become detectable. PMID:24487047

  16. Visual field protective effect of Erigeron breviscapus (vant.) Hand. Mazz. extract on glaucoma with controlled intraocular pressure: a randomized, double-blind, clinical trial.

    PubMed

    Zhong, Yisheng; Xiang, Minhong; Ye, Wen; Cheng, Yu; Jiang, Youqin

    2010-01-01

    To evaluate the visual field protective effect of Erigeron breviscapus (vant.) Hand. Mazz. (EBHM) extract on glaucoma with controlled intraocular pressure (IOP). Forty patients (40 eyes) with primary open-angle glaucoma, visual field defects and a postsurgical IOP of <18 mmHg were enrolled. The EBHM and placebo tablets were given orally according to the randomized and double-blind principle. Two tablets (of either EBHM or placebo) were taken three times a day for a period of 6 months. Patients were examined every 2 months after treatment commenced. At the end of the study, the results were given to the drug manufacturer. All patients completed the prospective, randomized, double-blind, clinical trial. No obvious adverse effects were found in patients during the treatment period. In the placebo group, no significant difference was found in mean defect (MD) or mean sensitivity (MS) between the values at pre-treatment and after 2, 4, and 6 months of treatment. After 6 months of EBHM treatment, the MD was significantly decreased and the MS was significantly increased compared with pre-treatment (p < 0.05). In the patients with moderate and late glaucoma, the MD was significantly decreased and the MS was significantly increased after 2, 4, and 6 months of EBHM treatment compared with pre-treatment. EBHM extract may have a partial protective effect on the visual field of glaucoma patients with controlled IOP. Further studies are needed to determine the safety and effectiveness of long-term EBHM treatment.

  17. Intrasellar cysticercosis: a systematic review.

    PubMed

    Del Brutto, Oscar H; Del Brutto, Victor J

    2013-09-01

    The objective of this study was to review patients with intrasellar cysticercosis to outline the features of this form of neurocysticercosis. A MEDLINE and manual search of patients with intrasellar cysticercosis were done. Abstracted data included clinical manifestations, neuroimaging findings, therapy, and outcome. Twenty-three patients were reviewed. Ophthalmological disturbances, including diminution of visual acuity and visual field defects following a chiasmatic pattern, were recorded in 67 % of cases. Endocrine abnormalities were found in 56 % of patients (panhypopituitarism, hyperprolactinemia, diabetes insipidus, and isolated hypothyroidism). In addition, some patients complained of seizures or chronic headaches. Neuroimaging studies showed lesions confined to the sellar region in 47 % of cases. The remaining patients also had subarachnoid cysts associated or not with hydrocephalus, parenchymal brain cysts, or parenchymal brain calcifications. Thirteen patients underwent surgical resection of the sellar cyst through a craniotomy in nine cases and by the transsphenoidal approach in four. Visual acuity or visual field defects improved in only two of these patients. Five patients were treated with cysticidal drugs without improvement. Intrasellar cysticercosis is rare and probably under-recognized. Clinical manifestations resemble those caused by pituitary tumors, cysts, or other granulomatous lesions. Neuroimaging findings are of more value when intrasellar cysts are associated with other forms of neurocysticercosis, such as basal subarachnoid cysts or hydrocephalus. Prompt surgical resection is mandatory to reduce the risk of permanent loss of visual function. There seems to be no role for cysticidal drug therapy in these cases.

  18. Retinitis Pigmentosa Sine Pigmento Mimicking a Chiasm Disease.

    PubMed

    Pellegrini, Francesco; Prosdocimo, Giovanni; Romano, Francesco; Interlandi, Emanuela

    2017-08-01

    A 75-year-old woman presented to her ophthalmologist complaining of visual loss for several years. The ophthalmic examination was remarkable for a bitemporal visual field defect. Magnetic resonance imaging (MRI) scan of the brain was normal without evidence of chiasm compression. Neuro-ophthalmic examination was consistent with a retinal rather than a chiasmal disease. Retinal multimodal imaging helped in the correct diagnosis of retinitis pigmentosa, later confirmed by genetic testing.

  19. Image gathering and digital restoration for fidelity and visual quality

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Alter-Gartenberg, Rachel; Rahman, Zia-Ur

    1991-01-01

    The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

  20. Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study.

    PubMed

    García-Domene, M C; Luque, M J; Díez-Ajenjo, M A; Desco-Esteban, M C; Artigas, J M

    2018-02-01

    To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, and the homogeneity of the sensibility of the magnocellular pathway depends on the choroidal thickness; when the thickness decreases, the sensitivity impairment extends from the center to the periphery of the visual field. Patients with high myopia without any fundus changes have visual impairments. We have found that choroidal thickness correlates with perceptual parameters such as contrast sensitivity or mean defect and pattern standard deviation of the visual fields of some visual pathways. Our study shows that the magnocellular and koniocellular pathways are the most affected, so that these patients have impairment in motion perception and blue-yellow contrast perception. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Exploring eye movements in patients with glaucoma when viewing a driving scene.

    PubMed

    Crabb, David P; Smith, Nicholas D; Rauscher, Franziska G; Chisholm, Catharine M; Barbur, John L; Edgar, David F; Garway-Heath, David F

    2010-03-16

    Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of 'point-of-regard' of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive.

  2. Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene

    PubMed Central

    Crabb, David P.; Smith, Nicholas D.; Rauscher, Franziska G.; Chisholm, Catharine M.; Barbur, John L.; Edgar, David F.; Garway-Heath, David F.

    2010-01-01

    Background Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). Methodology/Principal Findings The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of ‘point-of-regard’ of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Conclusions/Significance Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive. PMID:20300522

  3. Characterization technique for detection of atom-size crystalline defects and strains using two-dimensional fast-Fourier-transform sampling Moiré method

    NASA Astrophysics Data System (ADS)

    Kodera, Masako; Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Yoshioka, Akira; Sugiyama, Toru; Hamamoto, Takeshi; Miyashita, Naoto

    2018-04-01

    Recently, we have developed a two-dimensional (2D) fast-Fourier-transform (FFT) sampling Moiré technique to visually and quantitatively determine the locations of minute defects in a transmission electron microscopy (TEM) image. We applied this technique for defect detection with GaN high electron mobility transistor (HEMT) devices, and successfully and clearly visualized atom-size defects in AlGaN/GaN crystalline structures. The defect density obtained in the AlGaN/GaN structures is ∼1013 counts/cm2. In addition, we have successfully confirmed that the distribution and number of defects closely depend on the process conditions. Thus, this technique is quite useful for a device development. Moreover, the strain fields in an AlGaN/GaN crystal were effectively calculated with nm-scale resolution using this method. We also demonstrated that this sampling Moiré technique is applicable to silicon devices, which have principal directions different from those of AlGaN/GaN crystals. As a result, we believe that the 2D FFT sampling Moiré method has great potential applications to the discovery of new as yet unknown phenomena occurring between the characteristics of a crystalline material and device performance.

  4. Comparison of optical coherence tomography findings and visual field changes in patients with primary open-angle glaucoma and amyotrophic lateral sclerosis.

    PubMed

    Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei

    2018-02-01

    Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. A matter of time: improvement of visual temporal processing during training-induced restoration of light detection performance

    PubMed Central

    Poggel, Dorothe A.; Treutwein, Bernhard; Sabel, Bernhard A.; Strasburger, Hans

    2015-01-01

    The issue of how basic sensory and temporal processing are related is still unresolved. We studied temporal processing, as assessed by simple visual reaction times (RT) and double-pulse resolution (DPR), in patients with partial vision loss after visual pathway lesions and investigated whether vision restoration training (VRT), a training program designed to improve light detection performance, would also affect temporal processing. Perimetric and campimetric visual field tests as well as maps of DPR thresholds and RT were acquired before and after a 3 months training period with VRT. Patient performance was compared to that of age-matched healthy subjects. Intact visual field size increased during training. Averaged across the entire visual field, DPR remained constant while RT improved slightly. However, in transition zones between the blind and intact areas (areas of residual vision) where patients had shown between 20 and 80% of stimulus detection probability in pre-training visual field tests, both DPR and RT improved markedly. The magnitude of improvement depended on the defect depth (or degree of intactness) of the respective region at baseline. Inter-individual training outcome variability was very high, with some patients showing little change and others showing performance approaching that of healthy controls. Training-induced improvement of light detection in patients with visual field loss thus generalized to dynamic visual functions. The findings suggest that similar neural mechanisms may underlie the impairment and subsequent training-induced functional recovery of both light detection and temporal processing. PMID:25717307

  6. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  7. The ophthalmic natural history of paediatric craniopharyngioma: a long-term review.

    PubMed

    Drimtzias, Evangelos; Falzon, Kevin; Picton, Susan; Jeeva, Irfan; Guy, Danielle; Nelson, Olwyn; Simmons, Ian

    2014-12-01

    We present our experience over the long-term of monitoring of visual function in children with craniopharyngioma. Our study involves an analysis of all paediatric patients with craniopharyngioma younger than 16 at the time of diagnosis and represents a series of predominantly sub-totally resected tumours. Visual data, of multiple modality, of the paediatric patients was collected. Twenty patients were surveyed. Poor prognostic indicators of the visual outcome and rate of recurrence were assessed. Severe visual loss and papilledema at the time of diagnosis were more common in children under the age of 6. In our study visual signs, tumour calcification and optic disc atrophy at presentation are predictors of poor visual outcome with the first two applying only in children younger than 6. In contrast with previous reports, preoperative visual field (VF) defects and type of surgery were not documented as prognostic indicators of poor postoperative visual acuity (VA) and VF. Contrary to previous reports calcification at diagnosis, type of surgery and preoperative VF defects were not found to be associated with tumour recurrence. Local recurrence is common. Younger age at presentation is associated with a tendency to recur. Magnetic resonance imaging (MRI) remains the recommended means of follow-up in patients with craniopharyngioma.

  8. Visual Sensitivities and Discriminations and Their Role in Aviation

    DTIC Science & Technology

    1987-10-30

    both x and y, Aimn can be found by using one quarter of the plane. Hence 2P0r far.eco(-keosy) Ahm = i coa nv (coa x + kcoa y)cos mx dx dy since f(z,y...198-201. 142. Neima D, LeBlanc R & Regan D (1984) Visual field defects in ocular hypertension and glaucoma . Arch Ophthalmol 102, 1042-5. 143. Regan D...Neima D (1984) Visual fatigue and VEPs in multiple sclerosis, glaucoma , ocular hypertension and Parkinson’s disease. J Neurol Neurosurg Psychiat 47

  9. Polarization imaging of imperfect m-plane GaN surfaces

    NASA Astrophysics Data System (ADS)

    Sakai, Yuji; Kawayama, Iwao; Nakanishi, Hidetoshi; Tonouchi, Masayoshi

    2017-04-01

    Surface polar states in m-plane GaN wafers were studied using a laser terahertz (THz) emission microscope (LTEM). Femtosecond laser illumination excites THz waves from the surface due to photocarrier acceleration by local spontaneous polarization and/or the surface built-in electric field. The m-plane, in general, has a large number of unfavorable defects and unintentional polarization inversion created during the regrowth process. The LTEM images can visualize surface domains with different polarizations, some of which are hard to visualize with photoluminescence mapping, i.e., non-radiative defect areas. The present study demonstrates that the LTEM provides rich information about the surface polar states of GaN, which is crucial to improve the performance of GaN-based optoelectronic and power devices.

  10. Unsupervised Gaussian Mixture-Model With Expectation Maximization for Detecting Glaucomatous Progression in Standard Automated Perimetry Visual Fields.

    PubMed

    Yousefi, Siamak; Balasubramanian, Madhusudhanan; Goldbaum, Michael H; Medeiros, Felipe A; Zangwill, Linda M; Weinreb, Robert N; Liebmann, Jeffrey M; Girkin, Christopher A; Bowd, Christopher

    2016-05-01

    To validate Gaussian mixture-model with expectation maximization (GEM) and variational Bayesian independent component analysis mixture-models (VIM) for detecting glaucomatous progression along visual field (VF) defect patterns (GEM-progression of patterns (POP) and VIM-POP). To compare GEM-POP and VIM-POP with other methods. GEM and VIM models separated cross-sectional abnormal VFs from 859 eyes and normal VFs from 1117 eyes into abnormal and normal clusters. Clusters were decomposed into independent axes. The confidence limit (CL) of stability was established for each axis with a set of 84 stable eyes. Sensitivity for detecting progression was assessed in a sample of 83 eyes with known progressive glaucomatous optic neuropathy (PGON). Eyes were classified as progressed if any defect pattern progressed beyond the CL of stability. Performance of GEM-POP and VIM-POP was compared to point-wise linear regression (PLR), permutation analysis of PLR (PoPLR), and linear regression (LR) of mean deviation (MD), and visual field index (VFI). Sensitivity and specificity for detecting glaucomatous VFs were 89.9% and 93.8%, respectively, for GEM and 93.0% and 97.0%, respectively, for VIM. Receiver operating characteristic (ROC) curve areas for classifying progressed eyes were 0.82 for VIM-POP, 0.86 for GEM-POP, 0.81 for PoPLR, 0.69 for LR of MD, and 0.76 for LR of VFI. GEM-POP was significantly more sensitive to PGON than PoPLR and linear regression of MD and VFI in our sample, while providing localized progression information. Detection of glaucomatous progression can be improved by assessing longitudinal changes in localized patterns of glaucomatous defect identified by unsupervised machine learning.

  11. VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry

    PubMed Central

    Weleber, Richard G.; Smith, Travis B.; Peters, Dawn; Chegarnov, Elvira N.; Gillespie, Scott P.; Francis, Peter J.; Gardiner, Stuart K.; Paetzold, Jens; Dietzsch, Janko; Schiefer, Ulrich; Johnson, Chris A.

    2015-01-01

    Purpose: To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. Methods: A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. Results: Cross-validation yielded an overall R2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test–retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. Conclusions: VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. Translational Relevance: VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials. PMID:25938002

  12. Predictors of visual outcome in patients operated for craniopharyngioma - a Danish national study.

    PubMed

    Jacobsen, Mads Forslund; Thomsen, Ann Sofia Skou; Bach-Holm, Daniella; Doroudian, Ghazaleh; Nissen, Kamilla Rothe; Fugleholm, Kåre; Poulsgaard, Lars; Siersma, Volkert; Heegaard, Steffen

    2018-02-01

    Craniopharyngioma often causes visual loss due to the close relation to the anterior visual pathways. This study investigates the incidence and predictors of visual outcomes in patients with craniopharyngioma. Data from sixty-six patients who underwent surgery for craniopharyngioma from 2009 to 2013 in Denmark were reviewed. Primary outcomes were visual acuity (VA) and visual field (VF) defects from pre-and postoperative visits. Secondary outcomes were optic nerve atrophy (OA) and papilledema. Fifty-eight patients were included. The VA of the patients 1-year after surgery improved by -0.16 log(MAR) (95%CI: -0.30 to -0.02; p = 0.0266). Visual field (VF) defects worsened in 17 eyes (30%), remained stable in 21 eyes (37%) and improved in 19 eyes (33%). The presence of papilledema and the absence of OA were significantly correlated with an improvement in VA postoperatively (p = 0.011 and p = 0.011, respectively). Patients undergoing surgery within a week or less after their first ophthalmological examination had a significant improvement in VA (-0.36; 95%CI: -0.62 to -0.09; p = 0.0099). Patients undergoing surgery using a subfrontal approach also showed improvement in VA (p = 0.048). Tumour recurrence had a significantly worse VA outcome (p = 0.0074). Patients show a slight improvement in VA 1-year after operation for craniopharyngioma. The presence of papilledema and early surgical intervention is associated with a significant improvement in VA. Early involvement of a dedicated ophthalmologist is recommended to secure an early detection of a visual decline and potential tumour recurrence. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Syringomyelia presenting with unilateral optic neuropathy: a case report.

    PubMed

    Ngoo, Qi Zhe; Tai, Evelyn Li Min; Wan Hitam, Wan Hazabbah

    2017-01-01

    In this case report, we present two cases of syringomyelia with optic neuropathy. In Case 1, a 36-year-old Malay lady presented to our clinic with acute onset of blurring of vision in her left eye that she experienced since past 1 month. She was diagnosed with syringomyelia 12 years ago and was on conservative management. Her visual acuity was 6/6 in the right eye and counting fingers at 1 m in the left. There was a positive relative afferent pupillary defect in her left eye. Optic nerve functions of her left eye were reduced. Visual field showed a left inferior field defect. Her extraocular muscle movements were full. Magnetic resonance imaging of the brain and spine showed syringomyelia at the level of C2-C6 and T2-T9. Both of her optic nerves were normal. Her condition improved with intravenous and oral corticosteroids. In Case 2, a 44-year-old Malay lady presented to our clinic with a progressive central scotoma in her right eye that she experienced since past 1 month. She had previous history of recurrent episodes of weakness in both of her lower limbs from past 8 months. Visual acuity in her right and left eye was 6/9 and 6/6, respectively. The relative afferent pupillary defect in her right eye was positive. Optic nerve functions of her right eye were affected. Visual field showed a central scotoma in her right eye. Her extraocular muscle movements were full. Fundoscopy of her right eye showed a pale optic disc. Her left eye fundus was normal. Magnetic resonance imaging of the brain and spine showed syringomyelia at T3-T6. Both of her optic nerves were normal. A diagnosis of syringomyelia with right optic atrophy was performed. Her condition improved with intravenous and oral corticosteroids. Optic neuropathy is a rare neuro-ophthalmic manifestation in patients with syringomyelia. Prompt diagnosis and timely management are essential to avoid a poor visual outcome. Intravenous corticosteroids are beneficial in the treatment of early optic neuropathy in syringomyelia.

  14. Retinitis Pigmentosa Sine Pigmento Mimicking a Chiasm Disease

    PubMed Central

    Pellegrini, Francesco; Prosdocimo, Giovanni; Romano, Francesco; Interlandi, Emanuela

    2017-01-01

    ABSTRACT A 75-year-old woman presented to her ophthalmologist complaining of visual loss for several years. The ophthalmic examination was remarkable for a bitemporal visual field defect. Magnetic resonance imaging (MRI) scan of the brain was normal without evidence of chiasm compression. Neuro-ophthalmic examination was consistent with a retinal rather than a chiasmal disease. Retinal multimodal imaging helped in the correct diagnosis of retinitis pigmentosa, later confirmed by genetic testing. PMID:29344059

  15. The Advanced Glaucoma Intervention Study (AGIS): 3. Baseline characteristics of black and white patients.

    PubMed

    1998-07-01

    The purpose of this report is to examine the differences at baseline in demographic, medical, and ophthalmic characteristics between blacks and whites enrolled in the Advanced Glaucoma Intervention Study (AGIS), a multicenter, randomized, clinical trial. Multicenter, randomized, controlled trial. A total of 332 black patients (451 eyes), 249 white patients (325 eyes), and 10 patients of other races (13 eyes) with open-angle glaucoma that could not be controlled by medical therapy alone participated. There was no intervention performed. The investigators compare the baseline demographic, medical, and ophthalmic characteristics of black and white patients, adjusting the comparisons for age and gender. Blacks in the study were younger than whites and had more systemic hypertension and diabetes than whites. The visual field defects of blacks on average were substantially more severe than those of whites. Intraocular pressures and visual acuity scores were similar in the two groups. Blacks were more hyperopic and had relatively fewer disk rim hemorrhages than whites. The findings of the current study concur with those of previous clinical studies of open-angle glaucoma that visual field defects are more severe in blacks than whites.

  16. Evidence for the Detection of Subclinical Retinal Involvement in Systemic Lupus Erythematosus and Sjögren Syndrome: A Potential Association with Therapies.

    PubMed

    Conigliaro, Paola; Triggianese, Paola; Draghessi, Gianluca; Canofari, Claudia; Aloe, Gianluca; Chimenti, Maria Sole; Valeri, Claudia; Nucci, Carlo; Perricone, Roberto; Cesareo, Massimo

    2018-06-14

    Retinal involvement in systemic lupus erythematosus (SLE) and Sjögren syndrome (SS) may be subclinical and thus underdiagnosed. We aimed at evaluating morphological and functional visual abnormalities in a cohort of SLE and SS patients in the absence of an overt clinical visual impairment. We also investigated potential associations between retinal disorders and disease activity, organ involvement, and treatment with steroid and/or hydroxychloroquine. The study comprised 42 SLE and 36 primary SS patients and 76 healthy controls (HC). Ophthalmological examination, standard automated perimetry, spectral-domain optical coherence tomography, and fundus perimetry were performed. Retinal thickness of the posterior pole was not different between SLE and HC groups, but it was reduced in the SS group compared with both the HC and the SLE group. In SLE and SS patients, mean defect and pattern standard deviation by standard automated perimetry were higher than in HC. Visual field index values were lower in both SLE and SS patients than in HC. SLE patients with nephritis displayed increased mean defect and pattern standard deviation and reduced visual field index values compared to patients without nephritis. In SLE and SS patients, fundus perimetry differential sensitivity was reduced, and mean defect values were higher than in HC. Disturbances in fundus perimetry in the SLE group were more prevalent in steroid-naïve patients and in SS patients who received a cumulative hydroxychloroquine dose > 1,000 g. Functional eye impairment was demonstrated in SLE patients, possibly associated with kidney involvement. In SLE, corticosteroids might exert a protective role. Morphological alterations and functional impairment were detected in SS patients, which may be linked to hydroxychloroquine toxicity. © 2018 S. Karger AG, Basel.

  17. Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry.

    PubMed

    Alnawaiseh, Maged; Hömberg, Lisann; Eter, Nicole; Prokosch, Verena

    2017-01-01

    To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.

  18. Morning glory syndrome associated with primary open angle glaucoma--case report.

    PubMed

    Bozić, Marija; Hentova-Senćanić, Paraskeva; Marković, Vujica; Marjanović, Ivan

    2014-01-01

    Morning glory syndrome (MGS) is a rare congenital optic disc anomaly, first reported in 1970. MGS is a nonprogressive and untreatable condition, which usually occurs as an isolated ocular anomaly, and can be associated with the increased incidence of nonrhegmatogenous retinal detachment, and also with strabismus, afferent pupillary defect, visual field defects, presence of hyaloids artery remnants, ciliary body cyst, congenital cataract, lid hemangioma and preretinal gliosis. We report a clinical case of MGS associated with primary open angle glaucoma. The use of sophisticated diagnostic tools, such as retinal tomography and visual field testing is limited if multiple eye conditions are present, since optic disc does not have "usual" appearance that can be analyzed according to standard statistical databases. In treating and follow up of glaucoma cases associated with other diseases and conditions that affect the appearance and function of the optic nerve head, sometimes the use of modern technological methods is limited due to difficult interpretation of the obtained results.

  19. The effect of mitomycin C trabeculectomy on the progression of visual field defect in normal-tension glaucoma.

    PubMed

    Hagiwara, Y; Yamamoto, T; Kitazawa, Y

    2000-03-01

    We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.

  20. Pupil response as a predictor of blindsight in hemianopia

    PubMed Central

    Sahraie, Arash; Trevethan, Ceri T.; MacLeod, Mary Joan; Urquhart, James; Weiskrantz, Lawrence

    2013-01-01

    Significantly above-chance detection of stimuli presented within the field defect of patients with postgeniculate lesions is termed “blindsight.” It has been proposed that those with blindsight are more likely to benefit from visual rehabilitation by repeated stimulation, leading to increased visual sensitivity within their field defect. Establishing the incidence of blindsight and developing an objective and reliable method for its detection are of great interest. Sudden onsets of a grating pattern in the absence of any change in light flux result in a transient constriction of the pupil, termed “pupil grating response.” The existence of pupil grating responses for stimuli presented within the blindfield has previously been reported in a hemianopic patient and two monkeys with removal of the primary visual cortex unilaterally. Here, we have systematically investigated the presence of a spatial channel of processing at a range of spatial frequencies using a psychophysical forced-choice technique and obtained the corresponding pupil responses in the blindfield of 19 hemianopic patients. In addition, in 13 cases we determined the pupil responses in a sighted field location that matched the blindfield eccentricities. Our findings demonstrate that blindfield pupil responses are similar to those for the sighted field, but attenuated in amplitude. Pupillometry correctly characterized the presence or absence of a significant psychophysical response and thus is worth measuring in the cortically blindfields as a predictor of intact psychophysical capacity. The incidence of blindsight where detection performance had been investigated psychophysically over a range of spatial frequencies was 70%. PMID:24145420

  1. Comparison of 30-2 Standard and Fast programs of Swedish Interactive Threshold Algorithm of Humphrey Field Analyzer for perimetry in patients with intracranial tumors.

    PubMed

    Singh, Manav Deep; Jain, Kanika

    2017-11-01

    To find out whether 30-2 Swedish Interactive Threshold Algorithm (SITA) Fast is comparable to 30-2 SITA Standard as a tool for perimetry among the patients with intracranial tumors. This was a prospective cross-sectional study involving 80 patients aged ≥18 years with imaging proven intracranial tumors and visual acuity better than 20/60. The patients underwent multiple visual field examinations using the two algorithms till consistent and repeatable results were obtained. A total of 140 eyes of 80 patients were analyzed. Almost 60% of patients undergoing perimetry with SITA Standard required two or more sessions to obtain consistent results, whereas the same could be obtained in 81.42% with SITA Fast in the first session itself. Of 140 eyes, 70 eyes had recordable field defects and the rest had no defects as detected by either of the two algorithms. Mean deviation (MD) (P = 0.56), pattern standard deviation (PSD) (P = 0.22), visual field index (P = 0.83) and number of depressed points at P < 5%, 2%, 1%, and 0.5% on MD and PSD probability plots showed no statistically significant difference between two algorithms. Bland-Altman test showed that considerable variability existed between two algorithms. Perimetry performed by SITA Standard and SITA Fast algorithm of Humphrey Field Analyzer gives comparable results among the patients of intracranial tumors. Being more time efficient and with a shorter learning curve, SITA Fast my be recommended as a standard test for the purpose of perimetry among these patients.

  2. Correlation of macular structure and function in a boy with primary foveomacular retinitis and sequence of changes over 5 years.

    PubMed

    Badhani, Anurag; Padhi, Tapas Ranjan; Panda, Gopal Krishna; Mukherjee, Sujoy; Das, Taraprasad; Jalali, Subhadra

    2017-08-01

    To describe the clinical characteristics, macular structure and function, and to document sequential changes over 5 years in a 10-year-old boy with bilateral primary foveomacular retinitis. A 10-year-old boy presented with sudden onset scotoma in both eyes, experienced after getting up from bed on a non-eclipse day. He persistently denied direct sun-gazing. He neither had any significant systemic illness, nor was using any medications. In addition to a detailed examination at presentation that included fundus fluorescein angiogram (FFA), electroretinogram (ERG), pattern ERG and electrooculogram (EOG), he was examined periodically for 5 years with Humphrey visual field (HVF), spectral domain optical coherence tomogram (SDOCT), Amsler grid charting and multifocal ERG. The macular structure and functions were analyzed over the years and correlated with the symptoms. All findings were bilaterally symmetrical at each visit. At presentation, his corrected visual acuity was 20/25 with subfoveal yellow dot similar to solar retinopathy, central scotoma with reduced foveal threshold in HVF 24-2, micropsia in Amsler grid, missing of two plates on Ishihara color vision chart, transfoveal full thickness hyper-reflective band on SD OCT, unremarkable FFA and normal foveal peak in mfERG. The flash ERG and EOG were unremarkable. A month later, his VA improved to 20/20, he had relative scotoma in Amsler grid, no scotoma in HVF (10-2), restoration of the inner segment of the photoreceptors with sharp defect involving ellipsoid and photoreceptor interdigitation zone in SDOCT and blunting of foveal peaks in mfERG. Three months later, his corrected VA was 20/20 with relative scotoma in Amsler grid, normal color vision, no scotoma in HVF 10-2 and unchanged SDOCT findings. In subsequent examinations at 6, 9, 14, 29, 39 and 60 months, he was symptomless with VA 20/20, unremarkable fundus, normal Amsler grid and HVF (normal foveal threshold), unchanged SDOCT findings and the reduced foveal peaks on mfERG in both eyes got normalized only at 60 months. Presented here is a case of bilaterally symmetrical idiopathic foveomacular retinitis that had a clinical appearance similar to solar retinopathy. The fundus changes persisted for 4 weeks, the symptoms and changes in Amsler grid lasted for 3 months, and the foveal threshold in visual fields normalized within 3 months. Maximum change in the SDOCT defect occurred within a month, and the extrafoveal defect in the ellipsoid and photoreceptor interdigitation line persisted despite resolution of symptoms and resolution of the visual field defect and normal distance vision. Probably, the foveal lesion detected on SDOCT was too small to cause a reduction in the distance visual acuity or show up in the visual field and mfERG later.

  3. Factors associated with developing a fear of falling in subjects with primary open-angle glaucoma.

    PubMed

    Adachi, Sayaka; Yuki, Kenya; Awano-Tanabe, Sachiko; Ono, Takeshi; Shiba, Daisuke; Murata, Hiroshi; Asaoka, Ryo; Tsubota, Kazuo

    2018-02-13

    To investigate the relationship between clinical risk factors, including visual field (VF) defects and visual acuity, and a fear of falling, among patients with primary open-angle glaucoma (POAG). All participants answered the following question at a baseline ophthalmic examination: Are you afraid of falling? The same question was then answered every 12 months for 3 years. A binocular integrated visual field was calculated by merging a patient's monocular Humphrey field analyzer VFs, using the 'best sensitivity' method. The means of total deviation values in the whole, superior peripheral, superior central, inferior central, and inferior peripheral VFs were calculated. The relationship between these mean VF measurements, and various clinical factors, against patients' baseline fear of falling and future fear of falling was analyzed using multiple logistic regression. Among 392 POAG subjects, 342 patients (87.2%) responded to the fear of falling question at least twice in the 3 years study period. The optimal regression model for patients' baseline fear of falling included age, gender, mean of total deviation values in the inferior peripheral VF and number of previous falls. The optimal regression equation for future fear of falling included age, gender, mean of total deviation values in the inferior peripheral VF and number of previous falls. Defects in the inferior peripheral VF area are significantly related to the development of a fear of falling.

  4. Bilateral Neuroretinitis in Cat Scratch Disease with Exudative, Obliterative Vasculitis in the Optic Disc.

    PubMed

    Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu

    2014-01-01

    A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.

  5. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma.

    PubMed

    Kasneci, Enkelejda; Black, Alex A; Wood, Joanne M

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior.

  6. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma

    PubMed Central

    Black, Alex A.

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior. PMID:28293433

  7. Asymmetries and Visual Field Summaries as Predictors of Glaucoma in the Ocular Hypertension Treatment Study

    PubMed Central

    Levine, Richard A.; Demirel, Shaban; Fan, Juanjuan; Keltner, John L.; Johnson, Chris A.; Kass, Michael A.

    2007-01-01

    Purpose To evaluate whether baseline visual field data and asymmetries between eyes predict the onset of primary open-angle glaucoma (POAG) in Ocular Hypertension Treatment Study (OHTS) participants. Methods A new index, mean prognosis (MP), was designed for optimal combination of visual field thresholds, to discriminate between eyes that developed POAG from eyes that did not. Baseline intraocular pressure (IOP) in fellow eyes was used to construct measures of IOP asymmetry. Age-adjusted baseline thresholds were used to develop indicators of visual field asymmetry and summary measures of visual field defects. Marginal multivariate failure time models were constructed that relate the new index MP, IOP asymmetry, and visual field asymmetry to POAG onset for OHTS participants. Results The marginal multivariate failure time analysis showed that the MP index is significantly related to POAG onset (P < 0.0001) and appears to be a more highly significant predictor of POAG onset than either mean deviation (MD; P = 0.17) or pattern standard deviation (PSD; P = 0.046). A 1-mm Hg increase in IOP asymmetry between fellow eyes is associated with a 17% increase in risk for development of POAG. When threshold asymmetry between eyes existed, the eye with lower thresholds was at a 37% greater risk of development of POAG, and this feature was more predictive of POAG onset than the visual field index MD, though not as strong a predictor as PSD. Conclusions The MP index, IOP asymmetry, and binocular test point asymmetry can assist in clinical evaluation of eyes at risk of development of POAG. PMID:16936102

  8. A study on the natural history of scanning behaviour in patients with visual field defects after stroke.

    PubMed

    Loetscher, Tobias; Chen, Celia; Wignall, Sophie; Bulling, Andreas; Hoppe, Sabrina; Churches, Owen; Thomas, Nicole A; Nicholls, Michael E R; Lee, Andrew

    2015-04-24

    A visual field defect (VFD) is a common consequence of stroke with a detrimental effect upon the survivors' functional ability and quality of life. The identification of effective treatments for VFD is a key priority relating to life post-stroke. Understanding the natural evolution of scanning compensation over time may have important ramifications for the development of efficacious therapies. The study aims to unravel the natural history of visual scanning behaviour in patients with VFD. The assessment of scanning patterns in the acute to chronic stages of stroke will reveal who does and does not learn to compensate for vision loss. Eye-tracking glasses are used to delineate eye movements in a cohort of 100 stroke patients immediately after stroke, and additionally at 6 and 12 months post-stroke. The longitudinal study will assess eye movements in static (sitting) and dynamic (walking) conditions. The primary outcome constitutes the change of lateral eye movements from the acute to chronic stages of stroke. Secondary outcomes include changes of lateral eye movements over time as a function of subgroup characteristics, such as side of VFD, stroke location, stroke severity and cognitive functioning. The longitudinal comparison of patients who do and do not learn compensatory scanning techniques may reveal important prognostic markers of natural recovery. Importantly, it may also help to determine the most effective treatment window for visual rehabilitation.

  9. Clinical Correlates of Computationally Derived Visual Field Defect Archetypes in Patients from a Glaucoma Clinic.

    PubMed

    Cai, Sophie; Elze, Tobias; Bex, Peter J; Wiggs, Janey L; Pasquale, Louis R; Shen, Lucy Q

    2017-04-01

    To assess the clinical validity of visual field (VF) archetypal analysis, a previously developed machine learning method for decomposing any Humphrey VF (24-2) into a weighted sum of clinically recognizable VF loss patterns. For each of 16 previously identified VF loss patterns ("archetypes," denoted AT1 through AT16), we screened 30,995 reliable VFs to select 10-20 representative patients whose VFs had the highest decomposition coefficients for each archetype. VF global indices and patient ocular and demographic features were extracted retrospectively. Based on resemblances between VF archetypes and clinically observed VF patterns, hypotheses were generated for associations between certain VF archetypes and clinical features, such as an association between AT6 (central island, representing severe VF loss) and large cup-to-disk ratio (CDR). Distributions of the selected clinical features were compared between representative eyes of certain archetypes and all other eyes using the two-tailed t-test or Fisher exact test. 243 eyes from 243 patients were included, representative of AT1 through AT16. CDR was more often ≥ 0.7 among eyes representative of AT6 (central island; p = 0.002), AT10 (inferior arcuate defect; p = 0.048), AT14 (superior paracentral defect; p = 0.016), and AT16 (inferior paracentral defect; p = 0.016) than other eyes. CDR was more often < 0.7 among eyes representative of AT1 (no focal defect; p < 0.001) and AT2 (superior defect; p = 0.027), which was also associated with ptosis (p < 0.001). AT12 (temporal hemianopia) was associated with history of stroke (p = 0.022). AT11 (concentric peripheral defect) trended toward association with trial lens correction > 6D (p = 0.069). Shared clinical features between computationally derived VF archetypes and clinically observed VF patterns support the clinical validity of VF archetypal analysis.

  10. Current concepts in the diagnosis, pathogenesis and management of nonarteritic anterior ischaemic optic neuropathy.

    PubMed

    Miller, N R; Arnold, A C

    2015-01-01

    Nonarteritic anterior ischaemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Patients typically present with acute, painless, unilateral loss of vision associated with a variable visual field defect, a relative afferent pupillary defect, a swollen, hyperaemic optic disc, and one or more flame-shaped peripapillary retinal haemorrhages. The pathogenesis of this condition is unknown, but it occurs primarily in patients with structurally small optic discs that have little or no cup and a variety of underlying vascular disorders that may or may not be known at the time of visual loss. There is no consistently beneficial medical or surgical treatment for the condition, but there are now animal models that allow testing of various potential therapies. About 40% of patients experience spontaneous improvement in visual acuity. Patients in whom NAION occurs in one eye have a 15-19% risk of developing a similar event in the opposite eye over the subsequent 5 years.

  11. Current concepts in the diagnosis, pathogenesis and management of nonarteritic anterior ischaemic optic neuropathy

    PubMed Central

    Miller, N R; Arnold, A C

    2015-01-01

    Nonarteritic anterior ischaemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Patients typically present with acute, painless, unilateral loss of vision associated with a variable visual field defect, a relative afferent pupillary defect, a swollen, hyperaemic optic disc, and one or more flame-shaped peripapillary retinal haemorrhages. The pathogenesis of this condition is unknown, but it occurs primarily in patients with structurally small optic discs that have little or no cup and a variety of underlying vascular disorders that may or may not be known at the time of visual loss. There is no consistently beneficial medical or surgical treatment for the condition, but there are now animal models that allow testing of various potential therapies. About 40% of patients experience spontaneous improvement in visual acuity. Patients in whom NAION occurs in one eye have a 15–19% risk of developing a similar event in the opposite eye over the subsequent 5 years. PMID:24993324

  12. Evaluation of Postural Control in Patients with Glaucoma Using a Virtual Reality Environment.

    PubMed

    Diniz-Filho, Alberto; Boer, Erwin R; Gracitelli, Carolina P B; Abe, Ricardo Y; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A

    2015-06-01

    To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in patients with glaucoma. Cross-sectional study. The study involved 42 patients with glaucoma with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Torque moments around the center of foot pressure on the force platform were measured, and the standard deviations of the torque moments (STD) were calculated as a measurement of postural stability and reported in Newton meters (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Patients with glaucoma had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) and rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared with those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with a history of falls in patients with glaucoma (incidence rate ratio, 1.85; 95% confidence interval, 1.30-2.63; P = 0.001). The study presented and validated a novel paradigm for evaluation of balance control in patients with glaucoma on the basis of the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with a history of falls and may help to provide a better understanding of balance control in patients with glaucoma. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of Postural Control in Glaucoma Patients Using a Virtual 1 Reality Environment

    PubMed Central

    Diniz-Filho, Alberto; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A.

    2015-01-01

    Purpose To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in glaucoma patients. Design Cross-sectional study. Participants The study involved 42 glaucoma patients with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Methods Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Main Outcome Measures Torque moments around the center of foot pressure on the force platform were measured and the standard deviations (STD) of these torque moments were calculated as a measurement of postural stability and reported in Newton meter (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Results Glaucoma patients had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) as well as rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared to those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with history of falls in glaucoma patients (incidence-rate ratio = 1.85; 95% CI: 1.30 – 2.63; P = 0.001). Conclusions The study presented and validated a novel paradigm for evaluation of balance control in glaucoma patients based on the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with history of falls and may help to provide a better understanding of balance control in glaucoma patients. PMID:25892017

  14. Clinical approach to optic neuropathies

    PubMed Central

    Behbehani, Raed

    2007-01-01

    Optic neuropathy is a frequent cause of vision loss encountered by ophthalmologist. The diagnosis is made on clinical grounds. The history often points to the possible etiology of the optic neuropathy. A rapid onset is typical of demyelinating, inflammatory, ischemic and traumatic causes. A gradual course points to compressive, toxic/nutritional and hereditary causes. The classic clinical signs of optic neuropathy are visual field defect, dyschromatopsia, and abnormal papillary response. There are ancillary investigations that can support the diagnosis of optic neuropathy. Visual field testing by either manual kinetic or automated static perimetry is critical in the diagnosis. Neuro-imaging of the brain and orbit is essential in many optic neuropathies including demyelinating and compressive. Newer technologies in the evaluation of optic neuropathies include multifocal visual evoked potentials and optic coherence tomography. PMID:19668477

  15. Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

    DOE PAGES

    Steed, Chad A.; Halsey, William; Dehoff, Ryan; ...

    2017-02-16

    Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system thatmore » allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.« less

  16. Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steed, Chad A.; Halsey, William; Dehoff, Ryan

    Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system thatmore » allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.« less

  17. Methods of using (1S,3S)-3-amino-4-difluoromethylenyl-1-cyclopentanoic acid

    DOEpatents

    Silverman, Richard B; Dewey, Stephen L; Miller, Steven

    2015-03-03

    (1S,3S)-3-amino-4-difluoromethylenyl-1-cyclopentanoic acid also known as CPP-115 or its pharmaceutically acceptable salts can be used to treat addiction and neurological disorders such as epilepsy without side effects such as visual field defects caused by vigabatrin (Sabril).

  18. The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs.

    PubMed

    Enders, Philip; Schaub, Friederike; Adler, Werner; Nikoluk, Roman; Hermann, Manuel M; Heindl, Ludwig M

    2017-04-01

    To assess the performance of Bruch's membrane opening (BMO)-based spectral domain optical coherence tomography (SD-OCT) of the optic nerve head for glaucoma detection in microdiscs in comparison with confocal scanning laser tomography (CSLT). Retrospective cohort study. 82 eyes of 82 patients with disc size <1.63 mm 2 underwent SD-OCT and CSLT measurements, visual field testing and clinical examination. BMO-based minimal rim width (BMO-MRW), retinal nerve fibre layer thickness (RNFLT) in SD-OCT and rim area measured in CSLT were compared and correlated with visual field defects. 51 patients with glaucoma, 11 patients with ocular hypertension (OHT) and 20 healthy controls had a mean disc area of 1.36±0.19 mm 2 in CSLT, and BMO area was 1.45±0.22 mm 2 (r=0.17; p=0.12). In patients with glaucoma, visual field mean defect was -7.5±6.7 dB. Global BMO-MRW correlated better with visual field function (Spearman's r=0.65; p<0.001) than RNFLT (r=0.58; p≤0.001) and CSLT rim area (r=0.47; p=0.004). BMO-MRW significantly deteriorated with progressive visual field loss (p<0.001). In receiver operating characteristic analysis, sensitivity of BMO-MRW was 68.6% at 95% specificity (area under curve (AUC)=0.87), similar to sensitivity of RNFLT (66.4%; AUC=0.81). Performance of CSLT rim area was significantly worse (AUC=0.70, p=0.008). In healthy controls, mean BMO-MRW was 344.3±64.1 µm, mean RNFLT 78.0±11.3 µm and CSLT mean rim area 1.07±0.18 mm 2 . In small optic discs, BMO-MRW and peripapillary RNFLT (OCT) have similar sensitivity to discriminate patients with glaucoma from normal controls; both exceed CSLT rim area in diagnostic power. In glaucomatous patients, BMO-MRW correlates strongest with visual field function. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Electric field-induced emission enhancement and modulation in individual CdSe nanowires.

    PubMed

    Vietmeyer, Felix; Tchelidze, Tamar; Tsou, Veronica; Janko, Boldizsar; Kuno, Masaru

    2012-10-23

    CdSe nanowires show reversible emission intensity enhancements when subjected to electric field strengths ranging from 5 to 22 MV/m. Under alternating positive and negative biases, emission intensity modulation depths of 14 ± 7% are observed. Individual wires are studied by placing them in parallel plate capacitor-like structures and monitoring their emission intensities via single nanostructure microscopy. Observed emission sensitivities are rationalized by the field-induced modulation of carrier detrapping rates from NW defect sites responsible for nonradiative relaxation processes. The exclusion of these states from subsequent photophysics leads to observed photoluminescence quantum yield enhancements. We quantitatively explain the phenomenon by developing a kinetic model to account for field-induced variations of carrier detrapping rates. The observed phenomenon allows direct visualization of trap state behavior in individual CdSe nanowires and represents a first step toward developing new optical techniques that can probe defects in low-dimensional materials.

  20. Adjuvant or radical fractionated stereotactic radiotherapy for patients with pituitary functional and nonfunctional macroadenoma

    PubMed Central

    2011-01-01

    Purpose To evaluate the efficacy and toxicity of stereotactic fractionated radiotherapy (SFRT) for patients with pituitary macroadenoma (PMA). Methods and Materials Between March 2000 and March 2009, 27 patients (male to female ratio, 1.25) with PMA underwent SFRT (median dose, 50.4 Gy). Mean age of the patients was 56.5 years (range, 20.3 - 77.4). In all but one patient, SFRT was administered for salvage treatment after surgical resection (transphenoidal resection in 23, transphenoidal resection followed by craniotomy in 2 and multiple transphenoidal resections in another patient). In 10 (37%) patients, the PMAs were functional (3 ACTH-secreting, 3 prolactinomas, 2 growth hormone-secreting and 2 multiple hormone-secretion). Three (11.1%) and 9 (33.3%) patients had PMA abutting and compressing the optic chiasm, respectively. Mean tumor volume was 2.9 ± 4.6 cm3. Eighteen (66.7%) patients had hypopituitarism prior to SFRT. The mean follow-up period after SFRT was 72.4 ± 37.2 months. Results Tumor size decreased for 6 (22.2%) patients and remained unchanged for 19 (70.4%) other patients. Two (7.4%) patients had tumor growth inside the prescribed treatment volume. The estimated 5-year tumor growth control was 95.5% after SFRT. Biochemical remission occurred in 3 (30%) patients with functional PMA. Two patients with normal anterior pituitary function before SFRT developed new deficits 25 and 65 months after treatment. The 5-year survival without new anterior pituitary deficit was thus 95.8%. Five patients with visual field defect had improved visual function and 1 patient with no visual defect prior to SFRT, but an optic chiasm abutting tumor, had a decline in visual function. The estimated 5-year vision and pituitary function preservation rates were 93.2% and 95.8%, respectively. Conclusions SFRT is a safe and effective treatment for patients with PMA, although longer follow-up is needed to evaluate long-term outcomes. In this study, approximately 1 patient with visual field defect out of two had an improved visual function. PMID:22152397

  1. Compact sensitive instrument for direct ultrasonic visualization of defects.

    PubMed

    Bar-Cohen, Y; Ben-Joseph, B; Harnik, E

    1978-12-01

    A simple ultrasonic imaging cell based on the confocal combination of a plano-concave lens and a concave spherical mirror is described. When used in conjunction with a stroboscopic schlieren visualization system, it has the main attributes of a practical nondestructive testing instrument: it is compact, relatively inexpensive, and simple to operate; its sensitivity is fair, resolution and fidelity are good; it has a fairly large field of view and a test piece can be readily scanned. The scope of its applicability is described and discussed.

  2. Laser Imaging of Airborne Acoustic Emission by Nonlinear Defects

    NASA Astrophysics Data System (ADS)

    Solodov, Igor; Döring, Daniel; Busse, Gerd

    2008-06-01

    Strongly nonlinear vibrations of near-surface fractured defects driven by an elastic wave radiate acoustic energy into adjacent air in a wide frequency range. The variations of pressure in the emitted airborne waves change the refractive index of air thus providing an acoustooptic interaction with a collimated laser beam. Such an air-coupled vibrometry (ACV) is proposed for detecting and imaging of acoustic radiation of nonlinear spectral components by cracked defects. The photoelastic relation in air is used to derive induced phase modulation of laser light in the heterodyne interferometer setup. The sensitivity of the scanning ACV to different spatial components of the acoustic radiation is analyzed. The animated airborne emission patterns are visualized for the higher harmonic and frequency mixing fields radiated by planar defects. The results confirm a high localization of the nonlinear acoustic emission around the defects and complicated directivity patterns appreciably different from those observed for fundamental frequencies.

  3. Myocardial infarction increases progressive visual field defects in well treated early primary open angle glaucoma--a prospective case control study.

    PubMed

    Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam

    2013-06-01

    The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.

  4. Temporal visual field defects are associated with monocular inattention in chiasmal pathology.

    PubMed

    Fledelius, Hans C

    2009-11-01

    Chiasmal lesions have been shown to give rise occasionally to uni-ocular temporal inattention, which cannot be compensated for by volitional eye movement. This article describes the assessments of 46 such patients with chiasmal pathology. It aims to determine the clinical spectrum of this disorder, including interference with reading. Retrospective consecutive observational clinical case study over a 7-year period comprising 46 patients with chiasmal field loss of varying degrees. Observation of reading behaviour during monocular visual acuity testing ascertained from consecutive patients who appeared unable to read optotypes on the temporal side of the chart. Visual fields were evaluated by kinetic (Goldmann) and static (Octopus) techniques. Five patients who clearly manifested this condition are presented in more detail. The results of visual field testing were related to absence or presence of uni-ocular visual inattentive behaviour for distance visual acuity testing and/or reading printed text. Despite normal eye movements, the 46 patients making up the clinical series perceived only optotypes in the nasal part of the chart, in one eye or in both, when tested for each eye in turn. The temporal optotypes were ignored, and this behaviour persisted despite instruction to search for any additional letters temporal to those, which had been seen. This phenomenon of unilateral visual inattention held for both eyes in 18 and was unilateral in the remaining 28 patients. Partial or full reversibility after treatment was recorded in 21 of the 39 for whom reliable follow-up data were available. Reading a text was affected in 24 individuals, and permanently so in six. A neglect-like spatial unawareness and a lack of cognitive compensation for varying degrees of temporal visual field loss were present in all the patients observed. Not only is visual field loss a feature of chiasmal pathology, but the higher visual function of affording attention within the temporal visual field by means of using conscious thought to invoke appropriate compensatory eye movement was also absent. This suggests the possibility of 'trans-synaptic dysfunction' caused by loss of visual input to higher visual centres. When inattention to the temporal side is manifest on monocular visual testing it should raise the suspicion of chiasmal pathology.

  5. 'I didn't see that coming': simulated visual fields and driving hazard perception test performance.

    PubMed

    Glen, Fiona C; Smith, Nicholas D; Jones, Lee; Crabb, David P

    2016-09-01

    Evidence is limited regarding specific types of visual field loss associated with unsafe driving. We use novel gaze-contingent software to examine the effect of simulated visual field loss on computer-based driving hazard detection with the specific aim of testing the impact of scotomata located to the right and left of fixation. The 'hazard perception test' is a component of the UK driving licence examination, which measures speed of detecting 15 different hazards in a series of real-life driving films. We have developed a novel eye-tracking and computer set up capable of generating a realistic gaze-contingent scotoma simulation (GazeSS) overlaid on film content. Thirty drivers with healthy vision completed three versions of the hazard perception test in a repeated measures experiment. In two versions, GazeSS simulated a scotoma in the binocular field of view to the left or right of fixation. A third version was unmodified to establish baseline performance. Participants' mean baseline hazard perception test score was 51 ± 7 (out of 75). This reduced to 46 ± 9 and 46 ± 11 when completing the task with a binocular visual field defect located to the left and right of fixation, respectively. While the main effect of simulated visual field loss on performance was statistically significant (p = 0.007), there were no average differences in the experimental conditions where a scotoma was located in the binocular visual field to the right or left of fixation. Simulated visual field loss impairs driving hazard detection on a computer-based test. There was no statistically significant difference in average performance when the simulated scotoma was located to the right or left of fixation of the binocular visual field, but certain types of hazard caused more difficulties than others. © 2016 Optometry Australia.

  6. Screening methods for post-stroke visual impairment: a systematic review.

    PubMed

    Hanna, Kerry Louise; Hepworth, Lauren Rachel; Rowe, Fiona

    2017-12-01

    To provide a systematic overview of the various tools available to screen for post-stroke visual impairment. A review of the literature was conducted including randomised controlled trials, controlled trials, cohort studies, observational studies, systematic reviews and retrospective medical note reviews. All languages were included and translation was obtained. Participants included adults ≥18 years old diagnosed with a visual impairment as a direct cause of a stroke. We searched a broad range of scholarly online resources and hand-searched articles registers of published, unpublished and on-going trials. Search terms included a variety of MESH terms and alternatives in relation to stroke and visual conditions. Study selection was performed by two authors independently. The quality of the evidence and risk of bias were assessed using the STROBE, GRACE and PRISMA statements. A total of 25 articles (n = 2924) were included in this review. Articles appraised reported on tools screening solely for visual impairments or for general post-stroke disabilities inclusive of vision. The majority of identified tools screen for visual perception including visual neglect (VN), with few screening for visual acuity (VA), visual field (VF) loss or ocular motility (OM) defects. Six articles reported on nine screening tools which combined visual screening assessment alongside screening for general stroke disabilities. Of these, three included screening for VA; three screened for VF loss; three screened for OM defects and all screened for VN. Two tools screened for all visual impairments. A further 19 articles were found which reported on individual vision screening tests in stroke populations; two for VF loss; 11 for VN and six for other visual perceptual defects. Most tools cannot accurately account for those with aphasia or communicative deficits, which are common problems following a stroke. There is currently no standardised visual screening tool which can accurately assess all potential post-stroke visual impairments. The current tools screen for only a number of potential stroke-related impairments, which means many visual defects may be missed. The sensitivity of those which screen for all impairments is significantly lowered when patients are unable to report their visual symptoms. Future research is required to develop a tool capable of assessing stroke patients which encompasses all potential visual deficits and can also be easily performed by both the patients and administered by health care professionals in order to ensure all stroke survivors with visual impairment are accurately identified and managed. Implications for Rehabilitation Over 65% of stroke survivors will suffer from a visual impairment, whereas 45% of stroke units do not assess vision. Visual impairment significantly reduces the quality of life, such as being unable to return to work, driving and depression. This review outlines the available screening methods to accurately identify stroke survivors with visual impairments. Identifying visual impairment after stroke can aid general rehabilitation and thus, improve the quality of life for these patients.

  7. OCT angiography of acute non-arteritic anterior ischemic optic neuropathy.

    PubMed

    Rougier, M-B; Delyfer, M-N; Korobelnik, J-F

    2017-02-01

    To describe changes of the retinal peripapillary microvasculature on optical coherence tomography angiography (OCT-A) in non-arteritic anterior ischemic optic (NAION) neuropathy. Observational study of 10 patients at the acute phase of NAION. OCT-A was performed using a 3mm×3mm square centered on the optic disc (Cirrus HD-OCT with Angioplex, Carl Zeiss Meditec, Dublin, CA). A qualitative comparison was made with the healthy fellow eye of each patient. All patients had a fluorescein angiography (HRA2, Heidelberg, Germany) and a visual field examination (Octopus 101 ® , Haag-Streit, USA). In the affected eyes, OCT-A showed clear modifications in the radial peripapillary network. In all these eyes, a focal disappearance of the superficial capillary radial pattern was present, twisted and irregular. In 8 eyes, there was also a lack of vascularization in some focal areas, appearing as dark areas. No correlation was found between the topography of the vascular alteration shown on OCT-A and visual field pattern defects. OCT-A is a new imaging technology able to demonstrate easily and safely the changes in the peripapillary capillary network during the acute phase of NAION. These changes are likely related to a decrease of the prelaminar optic nerve blood flow during the acute phase of NAION. Visual field defects are not correlated with OCT-A images, suggesting that they may be due mainly to disturbances in posterior ciliary artery blood flow. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Correlation between central corneal thickness and visual field defects, cup to disc ratio and retinal nerve fiber layer thickness in primary open angle glaucoma patients.

    PubMed

    Sarfraz, Muhammad Haroon; Mehboob, Mohammad Asim; Haq, Rana Intisar Ul

    2017-01-01

    To evaluate the correlation between Central Corneal Thickness (CCT) and Visual Field (VF) defect parameters like Mean Deviation (MD) and Pattern Standard Deviation (PSD), Cup-to-Disc Ratio (CDR) and Retinal Nerve Fibre Layer Thickness (RNFL-T) in Primary Open-Angle Glaucoma (POAG) patients. This cross sectional study was conducted at Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi from September 2015 to September 2016. Sixty eyes of 30 patients with diagnosed POAG were analysed. Correlation of CCT with other variables was studied. Mean age of study population was 43.13±7.54 years. Out of 30 patients, 19 (63.33%) were males and 11 (36.67%) were females. Mean CCT, MD, PSD, CDR and RNFL-T of study population was 528.57±25.47µm, -9.11±3.07, 6.93±2.73, 0.63±0.13 and 77.79±10.44µm respectively. There was significant correlation of CCT with MD, PSD and CDR (r=-0.52, p<0.001; r=-0.59, p<0.001;r=-0.41, p=0.001 respectively). The correlation of CCT with RNFL-T was not statistically significant (r=-0.14, p=0.284). Central corneal thickness had significant correlation with visual field parameters like mean deviation and pattern standard deviation, as well as with cup-to-disc ratio. However, central corneal thickness had no significant relationship with retinal nerve fibre layer thickness.

  9. 45 CFR 233.70 - Blindness.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... visual acuity of 20/200 or less in the better eye with correcting glasses or a field defect in which the... diseases of the eye or by an optometrist, whichever the individual so selects. (i) No examination is necessary when both eyes are missing. (ii) Where an initial eye examination or re-examination is necessary...

  10. 45 CFR 233.70 - Blindness.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... visual acuity of 20/200 or less in the better eye with correcting glasses or a field defect in which the... diseases of the eye or by an optometrist, whichever the individual so selects. (i) No examination is necessary when both eyes are missing. (ii) Where an initial eye examination or re-examination is necessary...

  11. Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry

    PubMed Central

    Hömberg, Lisann; Eter, Nicole

    2017-01-01

    Purpose To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). Materials and Methods 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3–6) or the control group (group B: RNFL score 0–2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Results Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. Conclusions In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP. PMID:29119021

  12. Solar retinopathy. A study from Nepal and from Germany.

    PubMed

    Rai, N; Thuladar, L; Brandt, F; Arden, G B; Berninger, T A

    1998-01-01

    319 patients with a solar retinopathy were seen in an eye clinic in Nepal within 20 months. All patients had either a positive history of sun-gazing or typical circumscribed scars in the foveal area. In more than 80% of the patients the visual acuity was 6/12 or better and did not deteriorate over time. 126 (40%) patients had a history of gazing at the sun during an eclipse, 33 (10%) were sun worshipers and 4 (1%) were in both categories. Three years later 29 patients were re-examined in a follow-up study. Only 16 had had visual disturbances directly after they had gazed into the sun. No colour vision defects were seen in any of the 44 affected eyes, when tested with Panel D 15, while four patients (6 eyes) had some uncertainty with the tritan plates of the Ishihara test charts. Metamorphopsia were recorded in 11 eyes. Five German patients with solar retinopathy were examined in more detail. Colour contrast sensitivity (CCS) was tested for the central and the peripheral visual field. CCS for tritan axis was raised in all patients for the central visual field, while it was normal for the peripheral visual field.

  13. Open-field arena boundary is a primary object of exploration for Drosophila

    PubMed Central

    Soibam, Benjamin; Mann, Monica; Liu, Lingzhi; Tran, Jessica; Lobaina, Milena; Kang, Yuan Yuan; Gunaratne, Gemunu H; Pletcher, Scott; Roman, Gregg

    2012-01-01

    Drosophila adults, when placed into a novel open-field arena, initially exhibit an elevated level of activity followed by a reduced stable level of spontaneous activity and spend a majority of time near the arena edge, executing motions along the walls. In order to determine the environmental features that are responsible for the initial high activity and wall-following behavior exhibited during exploration, we examined wild-type and visually impaired mutants in arenas with different vertical surfaces. These experiments support the conclusion that the wall-following behavior of Drosophila is best characterized by a preference for the arena boundary, and not thigmotaxis or centrophobicity. In circular arenas, Drosophila mostly move in trajectories with low turn angles. Since the boundary preference could derive from highly linear trajectories, we further developed a simulation program to model the effects of turn angle on the boundary preference. In an hourglass-shaped arena with convex-angled walls that forced a straight versus wall-following choice, the simulation with constrained turn angles predicted general movement across a central gap, whereas Drosophila tend to follow the wall. Hence, low turn angled movement does not drive the boundary preference. Lastly, visually impaired Drosophila demonstrate a defect in attenuation of the elevated initial activity. Interestingly, the visually impaired w1118 activity decay defect can be rescued by increasing the contrast of the arena's edge, suggesting that the activity decay relies on visual detection of the boundary. The arena boundary is, therefore, a primary object of exploration for Drosophila. PMID:22574279

  14. The optic pathway: the development of an eLearning animation.

    PubMed

    Cooper, Claire; Erolin, Caroline

    2018-04-01

    The optic pathway is responsible for sending visual information from the eyes to the brain via electrical impulses. It is essential that a sound understanding of this pathway is established in order to determine an accurate diagnosis concerning visual field defects. Although easy for trained neurologists to understand, it is an area which medical students repeatedly struggle to visualise. It is proposed that audio-visual teaching resources can improve students understanding of complex areas of importance. This article describes the development and evaluation of a short animation created for use in the undergraduate neurology curriculum at the University of Dundee School of Medicine.

  15. A view on glaucoma—are we seeing it clearly?

    PubMed Central

    Crabb, D P

    2016-01-01

    Successful clinical management of glaucoma should not simply be about control of intraocular pressure, but must equate to correct decisions about intensifying treatment when patients are at risk of developing ‘visual disability'. Yet little is known about what visual field defects, at different stages of glaucoma, specifically affect patients' abilities to perform everyday visual tasks. One way to do this is to measure patient performance in tasks in a lab setting. Another way is to ask patients themselves. The latter can be revealing and demystify views about how patients perceive the world. This short commentary highlights some of the current research in this area. PMID:26611846

  16. Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

    NASA Technical Reports Server (NTRS)

    Plotnikov, Yuri A.; Winfree, William P.

    1999-01-01

    A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

  17. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.

    PubMed

    Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-07-01

    To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.

  18. Effect of a patient training video on visual field test reliability

    PubMed Central

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-01-01

    Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740

  19. Effect of a patient training video on visual field test reliability.

    PubMed

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-02-01

    To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarize them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye.

  20. Ocular vascular occlusive disorders: Natural history of visual outcome☆

    PubMed Central

    Hayreh, Sohan Singh

    2014-01-01

    Ocular vascular occlusive disorders collectively constitute the most common cause of visual disability. Before a disease can be managed, it is essential to understand its natural history, so as to be able to assess the likely effectiveness of any intervention. I investigated natural history of visual outcome in prospective studies of 386 eyes with non-arteritic anterior ischemic optic neuropathy (NA-AION), 16 eyes with non-arteritic posterior ischemic optic neuropathy, 697 eyes with central retinal vein occlusion (CRVO), 67 eyes with hemi-CRVO (HCRVO), 216 eyes with branch retinal vein occlusion (BRVO), 260 eyes with central retinal artery occlusion (CRAO), 151 eyes with branch retinal artery occlusion (BRAO) and 61 eyes with cilioretinal artery occlusion (CLRAO). My studies have shown that every one of these disorders consists of multiple distinct clinical sub-categories with different visual findings. When an ocular vascular occlusive disorder is caused by giant cell arteritis, which is an ophthalmic emergency, it would be unethical to do a natural history study of visual outcome in them, because in this case early diagnosis and immediate, intensive high-dose steroid therapy is essential to prevent any further visual loss, not only in the involved eye but also in the fellow, normal eye. In NA-AION in eyes seen ≤2 weeks after the onset, visual acuity (VA) improved in 41% of those with VA 20/70 or worse, and visual field (VF) improved in 26% of those with moderate to severe VF defect. In non-ischemic CRVO eyes with VA 20/70 or worse, VA improved in 47% and in ischemic CRVO in 23%; moderate to severe VF defect improved in 79% in non-ischemic CRVO and in 27% in ischemic CRVO. In HCRVO, overall findings demonstrated that initial VA and VF defect and the final visual outcome were different in non-ischemic from ischemic HCRVO – much better in the former than the latter. In major BRVO, in eyes with initial VA of 20/70 or worse, VA improved in 69%, and moderate to severe VF defect improved in 52%. In macular BRVO with 20/70 or worse initial VA, it improved in 53%, and initial minimal-mild VF defect was stable or improved in 85%. In various types of CRAO there are significant differences in both initial and final VA and VF defects. In CRAO eyes seen within 7 days of onset and initial VA of counting fingers or worse, VA improved in 82% with transient non-arteritic CRAO, 67% with non-arteritic CRAO with cilioretinal artery sparing, 22% with non-arteritic CRAO. Central VF improved in 39% of transient non-arteritic CRAO, 25% of non-arteritic CRAO with cilioretinal artery sparing and 21% of non-arteritic CRAO. Peripheral VF improved in non-arteritic CRAO in 39% and in transient non-arteritic CRAO in 39%. In transient CRAO, finally peripheral VFs were normal in 93%. In non-arteritic CRAO eyes initially 22% had normal peripheral VF and in the rest it improved in 39%. Final VA of 20/40 or better was seen in 89% of permanent BRAO, and in 100% of transient BRAO and non-arteritic CLRAO. In permanent BRAO eyes, among those seen within 7 days of onset, central VF defect improved in 47% and peripheral VF in 52%, and in transient BRAO central and peripheral VFs were normal at follow-up. My studies showed that AION, CRVO, BRVO, CRAO and BRAO, each consist of multiple distinct clinical sub-categories with different visual outcome. Contrary to the prevalent impression, these studies on the natural history of visual outcome have shown that there is a statistically significant spontaneous visual improvement in each category. The factors which influence the visual outcome in various ocular vascular occlusive disorders are discussed. PMID:24769221

  1. Quantitative analysis of external limiting membrane, ellipsoid zone and interdigitation zone defects in patients with macular holes.

    PubMed

    Houly, Jacques Ramos; Veloso, Carlos Eduardo; Passos, Elke; Nehemy, Márcio Bittar

    2017-07-01

    To investigate the correlation between the length of external limiting membrane (ELM), ellipsoid zone (EZ) and interdigitation zone (IZ) defects and visual prognosis in patients undergoing macular hole (MH) surgery, using spectral-domain optical coherence tomography (SD-OCT). This is a retrospective, consecutive, observational case series study. Fifty-two eyes of 52 patients with primary MH were evaluated. A quantitative analysis of ELM, EZ and IZ defects was performed preoperatively and at 3 and 6 months postoperatively using SD-OCT. The correlation between pre- and postoperative ELM, EZ and IZ defects and the best-corrected visual acuity (BCVA) was investigated. The lengths of ELM, EZ and IZ defects correlated significantly with BCVA in each study period (P < 0.001). Preoperative measures of these band defects were also associated with visual outcomes 3 and 6 months after surgery (P < 0.05). Considering all preoperative parameters, the length of the ELM defect was the factor most strongly correlated with BCVA at 6 months (β = 0.643, P < 0.012). The integrity of the ELM was the only factor significantly associated with BCVA at 6 months (β = 0.427; P = 0.004). The preoperative length of the ELM defect is the strongest predictor of visual acuity after MH surgery. Postoperative integrity of the ELM is significantly associated with visual restoration after surgical treatment of MH.

  2. Could Buerger's disease cause nonarteritic anterior ischemic optic neuropathy?: a rare case report.

    PubMed

    Korkmaz, Anil; Karti, Omer; Top Karti, Dilek; Yüksel, Bora; Zengin, Mehmet Ozgur; Kusbeci, Tuncay

    2018-04-05

    We present an interesting case with nonarteritic anterior ischemic optic neuropathy (NAION) accompanied by Buerger's disease. A 43-year-old man was referred to our neuro-ophthalmology clinic with a complaint of visual deterioration in the left eye that started 5 days ago. He suffered from Buerger's disease, and he had acute pain in the right lower limb below the knee. His best corrected visual acuity was 10/10 in the right eye and 2/10 in the left eye by Snellen chart. There was a relative afferent pupil defect in the left eye. The right optic disc was normal on fundus examination, and blurring, hemorrhagic swelling was found at the left optic disc. Inferior altitudinal visual field defect was observed in the left eye. Neurological examination was normal. Computed tomography angiography scan revealed occlusion in the right posterior tibial artery. Brain imaging and laboratory tests such as blood analyses, genetic screening, coagulation, and lipid panels were unremarkable. NAION may occur in patients with Buerger's disease, but it is extremely rare. Therefore, clinicians should be aware of this rare association.

  3. Nerve Fiber Flux Analysis Using Wide-Field Swept-Source Optical Coherence Tomography.

    PubMed

    Tan, Ou; Liu, Liang; Liu, Li; Huang, David

    2018-02-01

    To devise a method to quantify nerve fibers over their arcuate courses over an extended peripapillary area using optical coherence tomography (OCT). Participants were imaged with 8 × 8-mm volumetric OCT scans centered at the optic disc. A new quantity, nerve fiber flux (NFF), represents the cross-sectional area transected perpendicular to the nerve fibers. The peripapillary area was divided into 64 tracks with equal flux. An iterative algorithm traced the trajectory of the tracks assuming that the relative distribution of the NFF was conserved with compensation for fiber connections to ganglion cells on the macular side. Average trajectory was averaged from normal eyes and use to calculate the NFF maps for glaucomatous eyes. The NFF maps were divided into eight sectors that correspond to visual field regions. There were 24 healthy and 10 glaucomatous eyes enrolled. The algorithm converged on similar patterns of NFL tracks for all healthy eyes. In glaucomatous eyes, NFF correlated with visual field sensitivity in the arcuate sectors (Spearman ρ = 0.53-0.62). Focal nerve fiber loss in glaucomatous eyes appeared as uniform tracks of NFF defects that followed the expected arcuate fiber trajectory. Using an algorithm based on the conservation of flux, we derived nerve fiber trajectories in the peripapillary area. The NFF map is useful for the visualization of focal defects and quantification of sector nerve fiber loss from wide-area volumetric OCT scans. NFF provides a cumulative measure of volumetric loss along nerve fiber tracks and could improve the detection of focal glaucoma damage.

  4. Patterns of glaucomatous visual field loss in sita fields automatically identified using independent component analysis.

    PubMed

    Goldbaum, Michael H; Jang, Gil-Jin; Bowd, Chris; Hao, Jiucang; Zangwill, Linda M; Liebmann, Jeffrey; Girkin, Christopher; Jung, Tzyy-Ping; Weinreb, Robert N; Sample, Pamela A

    2009-12-01

    To determine if the patterns uncovered with variational Bayesian-independent component analysis-mixture model (VIM) applied to a large set of normal and glaucomatous fields obtained with the Swedish Interactive Thresholding Algorithm (SITA) are distinct, recognizable, and useful for modeling the severity of the field loss. SITA fields were obtained with the Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Inc, Dublin, California) on 1,146 normal eyes and 939 glaucoma eyes from subjects followed by the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. VIM modifies independent component analysis (ICA) to develop separate sets of ICA axes in the cluster of normal fields and the 2 clusters of abnormal fields. Of 360 models, the model with the best separation of normal and glaucomatous fields was chosen for creating the maximally independent axes. Grayscale displays of fields generated by VIM on each axis were compared. SITA fields most closely associated with each axis and displayed in grayscale were evaluated for consistency of pattern at all severities. The best VIM model had 3 clusters. Cluster 1 (1,193) was mostly normal (1,089, 95% specificity) and had 2 axes. Cluster 2 (596) contained mildly abnormal fields (513) and 2 axes; cluster 3 (323) held mostly moderately to severely abnormal fields (322) and 5 axes. Sensitivity for clusters 2 and 3 combined was 88.9%. The VIM-generated field patterns differed from each other and resembled glaucomatous defects (eg, nasal step, arcuate, temporal wedge). SITA fields assigned to an axis resembled each other and the VIM-generated patterns for that axis. Pattern severity increased in the positive direction of each axis by expansion or deepening of the axis pattern. VIM worked well on SITA fields, separating them into distinctly different yet recognizable patterns of glaucomatous field defects. The axis and pattern properties make VIM a good candidate as a preliminary process for detecting progression.

  5. Visual Impairment and Intracranial Hypertension: An Emerging Spaceflight Risk

    NASA Technical Reports Server (NTRS)

    Taddeo, Terrance A.

    2010-01-01

    During recent long duration missions to the International Space Station (ISS) crewmembers have reported changes in visual acuity or visual field defects. Exams in the postflight period revealed changes to the visual system and elevated intracranial pressures. As a result, NASA Space Medicine has added a number of tests to be performed in the preflight, inflight and postflight periods for ISS and shuttle missions with the goal of determining the processes at work and any potential mitigation strategies. This discussion will acquaint you with the changes that NASA has made to its medical requirements in order to address the microgravity induced intracranial hypertension and associated visual changes. Key personnel have been assembled to provide you information on this topic. Educational Objectives: Provide an overview of the current Medical Operations requirements and the mitigation steps taken to operationally address the issue.

  6. Patterns of Progressive Ganglion Cell-Inner Plexiform Layer Thinning in Glaucoma Detected by OCT.

    PubMed

    Shin, Joong Won; Sung, Kyung Rim; Park, Sun-Won

    2018-04-25

    To investigate the spatial characteristics and patterns of progressive macular ganglion cell-inner plexiform layer (GCIPL) thinning in glaucomatous eyes assessed by OCT Guided Progression Analysis (GPA). Longitudinal, retrospective, observational study. Two hundred ninety-two eyes of 192 patients with primary open-angle glaucoma with a mean follow-up of 6.0 years (range, 3.2-8.1 years) were included. Macular GCIPL imaging and visual field (VF) examination were performed at 6-month intervals for 3 years or more. Progressive GCIPL thinning was evaluated by a Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) GPA device. Spatial characteristics of progressive GCIPL thinning were assessed by the GCIPL thickness change map. The pattern of progressive GCIPL thinning was evaluated by comparing the baseline GCIPL thickness deviation map and the final GCIPL thickness change map. Visual field progression was determined by Early Manifest Glaucoma Trial criteria and linear regression of the VF index. Spatial characteristics and patterns of progressive GCIPL thinning. Seventy-two eyes of 62 participants (24.7% [72/292]) showed progressive GCIPL thinning in the GCIPL thickness change map. Progressive GCIPL thinning was detected most frequently (25.0%) at 2.08 mm from the fovea, and it extended in an arcuate shape in the inferotemporal region (250°-339°). Compared with the baseline GCIPL defects, the progressive GCIPL thinning extended toward the fovea and optic disc. The most common pattern of progressive GCIPL thinning was widening of GCIPL defects (42 eyes [58.3%]), followed by deepening of GCIPL defects (19 eyes [26.4%]) and newly developed GCIPL defects (15 eyes [20.8%]). Visual field progression was accompanied by progressive GCIPL thinning in 41 of 72 eyes (56.9%). Progressive GCIPL thinning preceded (61.0% [25/41]) or occurred concomitantly with (21.9% [9/41]) VF progression. The use of OCT GPA maps offers an effective approach to evaluate the topographic patterns of progressive GCIPL thinning in glaucomatous eyes. Progression of GCIPL thinning occurred before apparent progression on standard automated perimetry in most glaucomatous eyes. Understanding specific patterns and sequences of macular damage may provide important insights in the monitoring of glaucomatous progression. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Practical landmarks for visual field disability in glaucoma.

    PubMed

    Saunders, Luke J; Russell, Richard A; Crabb, David P

    2012-09-01

    To assess whether mean deviation (MD) from automated perimetry is related to the visual field (VF) component for legal fitness to drive (LFTD) in glaucoma patients. Monocular 24-2 VFs of 2604 patients with bilateral VF damage were retrospectively investigated. Integrated visual fields were calculated and used as a surrogate to assess LFTD according to current UK driving licence criteria. The better eye MD (BEMD), worse eye MD (WEMD) and a measure utilising MD of both eyes were compared, to assess respective diagnostic capabilities to predict LFTD (using the integrated visual field surrogate test as the gold standard) and a 'Probability of Failure' (PoF) for various defect levels was calculated. BEMD appears to be a good predictor of the VF component for a patient's LFTD (receiver operating characteristic area under the curve: 96.2%); MDs from both eyes offered no significant extra diagnostic power (area under the curve: 96.4%). PoF for BEMD thresholds of ≤-10 dB and ≤-14 dB were 70 (95% CI 66% to 74%) and 92% (87% to 95%), respectively. There is a strong relationship between BEMD and a patient's LFTD. PoF values for LFTD associated with readily available MD values provide practical landmarks for VF disability in glaucoma.

  8. Homonymous Visual Field Loss and Its Impact on Visual Exploration: A Supermarket Study.

    PubMed

    Kasneci, Enkelejda; Sippel, Katrin; Heister, Martin; Aehling, Katrin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-10-01

    Homonymous visual field defects (HVFDs) may critically interfere with quality of life. The aim of this study was to assess the impact of HVFDs on a supermarket search task and to investigate the influence of visual search on task performance. Ten patients with HVFDs (four with a right-sided [HR] and six with a left-sided defect [HL]), and 10 healthy-sighted, sex-, and age-matched control subjects were asked to collect 20 products placed on two supermarket shelves as quickly as possible. Task performance was rated as "passed" or "failed" with regard to the time per correctly collected item ( T C -failed = 4.84 seconds based on the performance of healthy subjects). Eye movements were analyzed regarding the horizontal gaze activity, glance frequency, and glance proportion for different VF areas. Seven of 10 HVFD patients (three HR, four HL) passed the supermarket search task. Patients who passed needed significantly less time per correctly collected item and looked more frequently toward the VFD area than patients who failed. HL patients who passed the test showed a higher percentage of glances beyond the 60° VF ( P < 0.05). A considerable number of HVFD patients performed successfully and could compensate for the HVFD by shifting the gaze toward the peripheral VF and the VFD area. These findings provide new insights on gaze adaptations in patients with HVFDs during activities of daily living and will enhance the design and development of realistic examination tools for use in the clinical setting to improve daily functioning. (http://www.clinicaltrials.gov, NCT01372319, NCT01372332).

  9. Glaucoma Diagnostic Capabilities of Foveal Avascular Zone Parameters Using Optical Coherence Tomography Angiography According to Visual Field Defect Location.

    PubMed

    Kwon, Junki; Choi, Jaewan; Shin, Joong Won; Lee, Jiyun; Kook, Michael S

    2017-12-01

    To assess the diagnostic ability of foveal avascular zone (FAZ) parameters to discriminate glaucomatous eyes with visual field defects (VFDs) in different locations (central vs. peripheral) from normal eyes. Totally, 125 participants were separated into 3 groups: normal (n=45), glaucoma with peripheral VFD (PVFD, n=45), and glaucoma with central VFD (CVFD, n=35). The FAZ area, perimeter, and circularity and parafoveal vessel density were calculated from optical coherence tomography angiography images. The diagnostic ability of the FAZ parameters and other structural parameters was determined according to glaucomatous VFD location. Associations between the FAZ parameters and central visual function were evaluated. A larger FAZ area and longer FAZ perimeter were observed in the CVFD group than in the PVFD and normal groups. The FAZ area, perimeter, and circularity were better in differentiating glaucomatous eyes with CVFDs from normal eyes [areas under the receiver operating characteristic curves (AUC), 0.78 to 0.88] than in differentiating PVFDs from normal eyes (AUC, 0.51 to 0.64). The FAZ perimeter had a similar AUC value to the circumpapillary retinal nerve fiber layer and macular ganglion cell-inner plexiform layer thickness for differentiating eyes with CVFDs from normal eyes (all P>0.05, the DeLong test). The FAZ area was significantly correlated with central visual function (β=-112.7, P=0.035, multivariate linear regression). The FAZ perimeter had good diagnostic capability in differentiating glaucomatous eyes with CVFDs from normal eyes, and may be a potential diagnostic biomarker for detecting glaucomatous patients with CVFDs.

  10. The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects.

    PubMed

    Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen

    2016-06-01

    To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.

  11. [Relationship between visual field index and visual field morphological stages of glaucoma and their diagnostic value].

    PubMed

    Hou, X R; Qin, J Y; Ren, Z Q

    2017-02-11

    Objective: To investigate the rationality of visual field morphological stages of glaucoma, its relationship with visual field index and their diagnostic value. Methods: Retrospective series case study. Two hundred and seventy-four glaucoma patients and 100 normal control received visual field examination by Humphrey perimeter using standard automatic perimetry (SAP) program from March 2014 to September 2014. Glaucoma patients were graded into four stages according to characteristic morphological damage of visual field, distribution of mean defect (MD) and visual field index (VFI) of each stage were plotted and receiver operation characteristic curve (ROC) was used to explore its correlation with MD and VFI. The diagnostic value of MD and VFI was also compared. For the comparison of general data of subjects, categorical variables were compared using χ(2) test, numerical variables were compared using F test. MD and VFI were compared using ANOVA among stages according to visual field, followed by multiple comparisons using LSD method. The correlation between MD and VFI and different stages according to visual field defined their diagnostic value, and compared using area under the curve (AUC) of ROC. Results: No characteristic visual field damage was found in normal control group, and MD and VFI was (-0.06±1.24) dB and (99.15±0.76)%, respectively. Glaucomatous visual field damage was graded into early, medium, late and end stage according to morphological characteristic. MD for each stage were (-2.83±2.00) dB, (-9.70±3.68) dB, (-18.46±2.90) dB, and (-27.96±2.76) dB, respectively. VFI for each stage were (93.84±3.61)%, (75.16±10.85)%, (49.36±11.26)% and (17.65±10.59)%, respectively. MD and VFI of each stage of glaucomatous group and normal control group were all significantly different ( F= 1 165.53 and P <0.01 for MD; F= 1 028.04 and P <0.01 for VFI). AUC of ROC was A(MD)=0.91 and Se(MD)=0.01 (95% confident interval was 0.89-0.94) for MD, and A(VFI)=0.97, Se(VFI)=0.01 (95% confident interval was 0.94-0.10) for VFI. So, AUC(VFI)>AUC(MD) ( P< 0.05). Conclusions: It is feasible and rational of glaucomatous visual field damage to be graded into early, medium, late and end stage using Humphrey perimeter. Distribution of MD and VFI for each stage was relatively concentrative. Both MD and VFI were useful for grading glaucomatous visual field damage with preference for VFI. (Chin J Ophthalmol, 2017, 53: 92-97) .

  12. Cerebral venous hypertension and blindness: a reversible complication.

    PubMed

    Cuadra, Salvador A; Padberg, Frank T; Turbin, Roger E; Farkas, Jeffrey; Frohman, Larry P

    2005-10-01

    A 57-year-old woman developed blindness during treatment for sarcoidosis-induced end-stage renal disease. An initial renal transplantation failed, and hemoaccess was maintained with multiple central catheters and upper extremity prosthetic arteriovenous grafts. A successful second transplantation eliminated her need for hemodialysis, but a right brachial to internal jugular graft remained patent. Progressive visual loss 2 years after transplantation prompted ophthalmic evaluation which initially revealed unilateral left optic nerve edema and visual loss, ultimately worsening over several months to no light perception in the left eye, 20/60 vision in the right eye, and bilateral papilledema. Arteriography demonstrated cerebral venous hypertension attributed to the functioning hemoaccess graft. Permanent graft occlusion normalized the papilledema, and visual field defects in the right eye and visual acuity returned to 20/20 in the right eye.

  13. Retinal damage caused by air-fluid exchange during pars plana vitrectomy.

    PubMed

    Yang, Sam S; McDonald, H Richard; Everett, A I; Johnson, Robert N; Jumper, J Michael; Fu, Arthur D

    2006-03-01

    To report two cases of retinal damage associated with air infusion during pars plana vitrectomy. Observational case report. The authors reviewed the course of two patients who had retinal damage during par plana vitrectomy and air-fluid exchange for the treatment of macular hole and optic pit-related macular detachment, respectively. The intraoperative observations, postoperative course, and outcomes were reported. As a result of high air infusion flow during air-fluid exchange, retinal damage was created in the area contralateral to the infusion port. In Case 1, an oval area of whitening was noted on the first postoperative day. This area subsequently developed into a large retinal break associated with retinal detachment. In the second case, retinal whitening was noted intraoperatively. This region of pallor resolved quickly during the early postoperative period but resulted in a corresponding inferotemporal visual field defect. High infusion flow during air-fluid exchange in eyes undergoing vitrectomy surgery may result in significant retinal damage. This pressure-induced trauma initially causes retinal whitening that may be seen intraoperatively or during the early postoperative period. The region of damaged retina may develop a retinal break and detachment or a corresponding visual field defect.

  14. Non-invasive electric current stimulation for restoration of vision after unilateral occipital stroke.

    PubMed

    Gall, Carolin; Silvennoinen, Katri; Granata, Giuseppe; de Rossi, Francesca; Vecchio, Fabrizio; Brösel, Doreen; Bola, Michał; Sailer, Michael; Waleszczyk, Wioletta J; Rossini, Paolo M; Tatlisumak, Turgut; Sabel, Bernhard A

    2015-07-01

    Occipital stroke often leads to visual field loss, for which no effective treatment exists. Little is known about the potential of non-invasive electric current stimulation to ameliorate visual functions in patients suffering from unilateral occipital stroke. One reason is the traditional thinking that visual field loss after brain lesions is permanent. Since evidence is available documenting vision restoration by means of vision training or non-invasive electric current stimulation future studies should also consider investigating recovery processes after visual cortical strokes. Here, protocols of repetitive transorbital alternating current stimulation (rtACS) and transcranial direct current stimulation (tDCS) are presented and the European consortium for restoration of vision (REVIS) is introduced. Within the consortium different stimulation approaches will be applied to patients with unilateral occipital strokes resulting in homonymous hemianopic visual field defects. The aim of the study is to evaluate effects of current stimulation of the brain on vision parameters, vision-related quality of life, and physiological parameters that allow concluding about the mechanisms of vision restoration. These include EEG-spectra and coherence measures, and visual evoked potentials. The design of stimulation protocols involves an appropriate sham-stimulation condition and sufficient follow-up periods to test whether the effects are stable. This is the first application of non-invasive current stimulation for vision rehabilitation in stroke-related visual field deficits. Positive results of the trials could have far-reaching implications for clinical practice. The ability of non-invasive electrical current brain stimulation to modulate the activity of neuronal networks may have implications for stroke rehabilitation also in the visual domain. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma.

    PubMed

    Bamdad, Shahram; Beigi, Vahid; Sedaghat, Mohammad Reza

    2017-01-01

    Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p < 0.5% and p < 1%) in pattern deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.

  16. Characteristics of eyes with inner retinal cleavage.

    PubMed

    Hwang, Young Hoon; Kim, Yong Yeon; Kim, Hwang Ki; Sohn, Yong Ho

    2015-02-01

    Inner retinal cleavage can be misdiagnosed as a glaucomatous retinal nerve fiber layer (RNFL) defect. This study was performed to characterize eyes with inner retinal cleavage. Inner retinal cleavage is defined as the appearance of a dark spindle-shaped space between the nerve fibers. Patients who presented at our institution with inner retinal cleavage were enrolled in the study. All participants were evaluated by fundus examination, visual field testing with standard automated perimetry, and optical coherence tomography (OCT) imaging. A total of 15 eyes of 11 subjects with inner retinal cleavage were included in the study. The median age of the subjects was 57 years (age range, 30-67 years). In each case, inner retinal cleavage was located adjacent to retinal blood vessels. Tissue bridging the cleavage area was observed in ten eyes. Six eyes had epiretinal membranes (ERMs), two eyes had glaucoma, and one eye had ERM in addition to glaucoma. Six eyes with inner retinal cleavage without combined ocular abnormalities had highly myopic refractive error (-6.50 to -8.50 diopters). Cross-sectional OCT images of the areas of inner retinal cleavage demonstrated defects with irregular margins and empty spaces in the inner layers of the retina. During the follow-up period, no eye showed changes in inner retinal layer cleavage or visual field sensitivity. Inner retinal cleavage was found in eyes with high myopia or ERMs. Inner retinal cleavage was associated with structural changes distinct from those associated with glaucomatous RNFL defects.

  17. What Do Patients With Glaucoma See? Visual Symptoms Reported by Patients With Glaucoma

    PubMed Central

    Hu, Cindy X.; Zangalli, Camila; Hsieh, Michael; Gupta, Lalita; Williams, Alice L.; Richman, Jesse

    2014-01-01

    Abstract: Background: Vision loss from glaucoma has traditionally been described as loss of “peripheral vision.” In this prospective study, we aimed to improve our clinical understanding of the visual symptoms caused by glaucoma by asking patients specific detailed questions about how they see. Methods: Patients who were clinically diagnosed with various types and stages of glaucoma were included. All had a comprehensive ocular examination, including Octopus visual field testing. Patients were excluded if they had other ocular conditions that affected their vision, including cornea, lens or retina pathologies. Patients responded to an oral questionnaire about their visual symptoms. We investigated the visual symptoms described by patients with glaucoma and correlated the severity of visual field loss with visual symptoms reported. Results: Ninety-nine patients completed the questionnaire. Most patients (76%) were diagnosed with primary open-angle glaucoma. The most common symptoms reported by all patients, including patients with early or moderate glaucoma, were needing more light and blurry vision. Patients with a greater amount of field loss (Octopus mean defect >+9.4 dB) were more likely to report difficulty seeing objects to one or both sides, as if looking through dirty glasses and trouble differentiating boundaries and colors. Conclusions: Vision loss in patients with glaucoma is not as simple as the traditional view of loss of peripheral vision. Needing more light and blurry vision were the most common symptoms reported by patients with glaucoma. PMID:24992392

  18. Patient-reported vision-related quality of life differences between superior and inferior hemifield visual field defects in primary open-angle glaucoma.

    PubMed

    Cheng, Hui-Chen; Guo, Chao-Yu; Chen, Mei-Ju; Ko, Yu-Chieh; Huang, Nicole; Liu, Catherine Jui-ling

    2015-03-01

    Previous studies have found that glaucoma is associated with impaired patient-reported vision-related quality of life (pVRQOL) but few, to our knowledge, have assessed how the visual field (VF) defect location impacts the pVRQOL. To investigate the associations of VF defects in the superior vs inferior hemifields with pVRQOL outcomes in patients with primary open-angle glaucoma. Prospective cross-sectional study at a tertiary referral center from March 1, 2012, to January 1, 2013, including patients with primary open-angle glaucoma who had a best-corrected visual acuity in the better eye equal to or better than 20/60 and reliable VF tests. The pVRQOL was assessed by a validated Taiwanese version of the 25-item National Eye Institute Visual Function Questionnaire. Reliable VF tests obtained within 3 months of enrollment were transformed to binocular integrated VF (IVF). The IVF was further stratified by VF location (superior vs inferior hemifield). The association between each domain of the 25-item National Eye Institute Visual Function Questionnaire and superior or inferior hemifield IVF was determined using multivariable linear regression analysis. The analysis included 186 patients with primary open-angle glaucoma with a mean age of 59.1 years (range, 19-86 years) and IVF mean deviation (MD) of -4.84 dB (range, -27.56 to 2.17 dB). In the multivariable linear regression analysis, the MD of the full-field IVF showed positive associations with near activities (β = 0.05; R2 = 0.20; P < .001), vision-specific role difficulties (β = 0.04; R2 = 0.19; P = .01), vision-specific dependency (β = 0.04; R2 = 0.20; P < .001), driving (β = 0.05; R2 = 0.24; P < .001), peripheral vision (β = 0.03; R2 = 0.18; P = .02), and composite scores (β = 0.04; R2 = 0.27; P = .005). Subsequent analysis showed that the MD of the superior hemifield IVF was associated only with near activities (β = 0.04; R2 = 0.21; P < .001) while the MD of the inferior hemifield IVF was associated with general vision (β = 0.04; R2 = 0.12; P = .01), vision-specific role difficulties (β = 0.04; R2 = 0.20; P = .01), and peripheral vision (β = 0.03; R2 = 0.17; P = .03). Superior hemifield IVF was strongly associated with difficulty with near activities. Inferior hemifield IVF impacted vision-specific role difficulties and general and peripheral vision. The impact of a VF defect on a patient's pVRQOL may depend not only on its severity, but also on its hemifield location.

  19. Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

    PubMed

    Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya

    2012-11-01

    Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

  20. Visual Dysfunction in Posterior Cortical Atrophy

    PubMed Central

    Maia da Silva, Mari N.; Millington, Rebecca S.; Bridge, Holly; James-Galton, Merle; Plant, Gordon T.

    2017-01-01

    Posterior cortical atrophy (PCA) is a syndromic diagnosis. It is characterized by progressive impairment of higher (cortical) visual function with imaging evidence of degeneration affecting the occipital, parietal, and posterior temporal lobes bilaterally. Most cases will prove to have Alzheimer pathology. The aim of this review is to summarize the development of the concept of this disorder since it was first introduced. A critical discussion of the evolving diagnostic criteria is presented and the differential diagnosis with regard to the underlying pathology is reviewed. Emphasis is given to the visual dysfunction that defines the disorder, and the classical deficits, such as simultanagnosia and visual agnosia, as well as the more recently recognized visual field defects, are reviewed, along with the evidence on their neural correlates. The latest developments on the imaging of PCA are summarized, with special attention to its role on the differential diagnosis with related conditions. PMID:28861031

  1. Charles Bonnet Syndrome in a Patient With Right Medial Occipital Lobe Infarction: Epileptic or Deafferentation Phenomenon?

    PubMed

    Kumral, Emre; Uluakay, Arzu; Dönmez, İlknur

    2015-07-01

    Charles Bonnet syndrome (CBS) is an uncommon disorder characterized by complex and recurrent visual hallucinations in patients with visual pathway pathologic defects. To describe a patient who experienced complex visual hallucinations following infarction in the right occipital lobe and epileptic seizure who was diagnosed as having CBS. A 65-year-old man presented acute ischemic stroke caused by artery to artery embolism involving the right occipital lobe. Following ischemic stroke, complex visual hallucinations in the left visual field not associated with loss of consciousness or delusion developed in the patient. Hallucinations persisted for >1 month and during hallucination, no electrographic seizures were recorded through 24 hours of videoelectroencephalographic monitoring. CBS may develop in a patient with occipital lobe infarction following an embolic event. CBS associated with medial occipital lobe infarction and epilepsy may coexist and reflects the abnormal functioning of an integrated neuronal network.

  2. Visual disability rates in a ten-year cohort of patients with anterior visual pathway meningiomas.

    PubMed

    Bor-Shavit, Elite; Hammel, Naama; Nahum, Yoav; Rappaport, Zvi Harry; Stiebel-Kalish, Hadas

    2015-01-01

    To examine the visual outcome of anterior visual pathway meningioma (AVPM) patients followed for at least one year. Data were collected on demographics, clinical course and management. Visual disability was classified at the first and last examination as follows: I--no visual disability; II--mild visual defect in one eye; III--mild visual defect in both eyes; IV--loss of driver's license; V--legally blind. Eight-one AVPM patients had their tumor originate in the clinoid process in 23 (28%), sphenoid-wing area in 18 (22%), cavernous sinus in 15 (19%), tuberculum sellae in 8 (10%), and mixed in 17 (21%). On last examination, 46 patients (57%) had good visual acuity in one or both eyes (Class I or II) and 17 (21%) were mildly affected in both eyes. The rate of Class IV disability was 16%, and Class V disability was 6%. Attention needs to be addressed to the considerable proportion of patients with AVPM (22% in this study) who may lose their driver's license or become legally blind. Occupational therapists should play an important role in the multidisciplinary management of those patients to help them adapt to their new physical and social situation. Anterior visual pathway meningiomas (AVPMs) are commonly not life-threatening but they can lead to profound visual disability, especially when the tumor originates in the tuberculum sellae and cavernous sinus. Particular attention should be paid to visual acuity and visual field deficits, as these can profoundly affect the patient's quality of life including ability to drive and activities of daily living. The interdisciplinary management of patients with AVPM should include the neurosurgeon, neuro-ophthalmologist and occupational therapist. Also, early intervention by the occupational therapist can help patients adapt to their current physical and social situation and return to everyday tasks more rapidly.

  3. Wide-field fundus autofluorescence imaging to evaluate retinal function in patients with retinitis pigmentosa.

    PubMed

    Ogura, Shuntaro; Yasukawa, Tsutomu; Kato, Aki; Usui, Hideaki; Hirano, Yoshio; Yoshida, Munenori; Ogura, Yuichiro

    2014-11-01

    To study the correlation between the visual fields (VF) and wide-field fundus autofluorescence (FAF) in patients with retinitis pigmentosa (RP). Retrospective, observational, consecutive case series. Twenty-four eyes of 12 patients diagnosed with RP were enrolled. The VFs measured by Goldmann perimetry and wide-field FAF images were compared for each eye. The relationship between the areas of hypoautofluorescence on the wide-field FAF images and scotoma on Goldmann perimetry were evaluated. The VF and FAF images in the central 60 degrees were trimmed and superimposed to calculate the percentage agreement between the hypoautofluorescence and the scotomas and between the isoautofluorescence and hyperautofluorescence and the remaining VFs. The areas of hypoautofluorescence on the FAF images were correlated significantly (R = 0.86, P < .001) with the areas of the VF defects on Goldmann perimetry. The mean percentage agreement between the hypoautofluorescence and the scotomas was 91.0% ± 7.7% and that of the isoautofluorescence and hyperautofluorescence with the remaining VFs was 84.5% ± 7.4%. The areas of geographic hypoautofluorescence with or without hyperautofluorescent bands reflected the VF defects, while nummular or mottled hypoautofluorescence without VF defects was seen in 7 eyes. These results suggested that wide-field FAF imaging is useful to evaluate the remaining retinal function in patients with RP. Abnormal fundus autofluorescence precedes loss of retinal function and is helpful for monitoring disease progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Clinical spectrum of lamellar macular defects including pseudoholes and pseudocysts defined by optical coherence tomography

    PubMed Central

    Chen, J C; Lee, L R

    2008-01-01

    Objective: To present the clinical spectrum of lamellar macular defects and describe the different subtypes based on their optical coherence tomography (OCT) configuration and visual prognosis. Methods: The retrospective observational case series reviewed OCT scans of 92 eyes with lamellar macular defects. Lamellar macular defects were categorised into subtypes of macular pseudohole (MPH), lamellar macular hole (LMH) and foveal pseudocyst (FP) according to their OCT morphology. The defects were quantitatively characterised in terms of base diameter, depth and central foveal thickness, and examined for the presence of associated epiretinal membranes (ERM). Results: Visual acuity (VA) was significantly correlated with the central foveal thickness and depth of the lamellar defect. MPH was associated with better VA compared with LMH and FP. MPH was of a smaller base diameter and had a greater central foveal thickness than that of LMH and FP. Fifty-per cent of all lamellar defects had an associated ERM. Conclusions: Different profiles of lamellar macular defects were characterised and quantified by OCT. Deeper and wider lamellar defects were associated with poorer visual outcome. Such objective parameters lamellar macular defects are of value when explaining to patients regarding their decreased acuity. Future prospective investigations are required to study the natural history of lamellar defects of different aetiology and surgical indications. PMID:18684752

  5. Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.

    PubMed

    Wu, Huijuan; de Boer, Johannes F; Chen, Teresa C

    2012-05-01

    To determine the diagnostic capability of spectral-domain optical coherence tomography in glaucoma patients with visual field defects. Prospective, cross-sectional study. Participants were recruited from a university hospital clinic. One eye of 85 normal subjects and 61 glaucoma patients with average visual field mean deviation of -9.61 ± 8.76 dB was selected randomly for the study. A subgroup of the glaucoma patients with early visual field defects was calculated separately. Spectralis optical coherence tomography (Heidelberg Engineering, Inc) circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Overall RNFL thickness had the highest area under the receiver operating characteristic curve values: 0.952 for all patients and 0.895 for the early glaucoma subgroup. For all patients, the highest sensitivity (98.4%; 95% confidence interval, 96.3% to 100%) was achieved by using 2 criteria: ≥ 1 RNFL sectors being abnormal at the < 5% level and overall classification of borderline or outside normal limits, with specificities of 88.9% (95% confidence interval, 84.0% to 94.0%) and 87.1% (95% confidence interval, 81.6% to 92.5%), respectively, for these 2 criteria. Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral-domain optical coherence tomography were good for early perimetric glaucoma and were excellent for moderately advanced perimetric glaucoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Advanced Image Processing for Defect Visualization in Infrared Thermography

    NASA Technical Reports Server (NTRS)

    Plotnikov, Yuri A.; Winfree, William P.

    1997-01-01

    Results of a defect visualization process based on pulse infrared thermography are presented. Algorithms have been developed to reduce the amount of operator participation required in the process of interpreting thermographic images. The algorithms determine the defect's depth and size from the temporal and spatial thermal distributions that exist on the surface of the investigated object following thermal excitation. A comparison of the results from thermal contrast, time derivative, and phase analysis methods for defect visualization are presented. These comparisons are based on three dimensional simulations of a test case representing a plate with multiple delaminations. Comparisons are also based on experimental data obtained from a specimen with flat bottom holes and a composite panel with delaminations.

  7. Homonymous Visual Field Loss and Its Impact on Visual Exploration: A Supermarket Study

    PubMed Central

    Kasneci, Enkelejda; Sippel, Katrin; Heister, Martin; Aehling, Katrin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Purpose Homonymous visual field defects (HVFDs) may critically interfere with quality of life. The aim of this study was to assess the impact of HVFDs on a supermarket search task and to investigate the influence of visual search on task performance. Methods Ten patients with HVFDs (four with a right-sided [HR] and six with a left-sided defect [HL]), and 10 healthy-sighted, sex-, and age-matched control subjects were asked to collect 20 products placed on two supermarket shelves as quickly as possible. Task performance was rated as “passed” or “failed” with regard to the time per correctly collected item (TC -failed = 4.84 seconds based on the performance of healthy subjects). Eye movements were analyzed regarding the horizontal gaze activity, glance frequency, and glance proportion for different VF areas. Results Seven of 10 HVFD patients (three HR, four HL) passed the supermarket search task. Patients who passed needed significantly less time per correctly collected item and looked more frequently toward the VFD area than patients who failed. HL patients who passed the test showed a higher percentage of glances beyond the 60° VF (P < 0.05). Conclusion A considerable number of HVFD patients performed successfully and could compensate for the HVFD by shifting the gaze toward the peripheral VF and the VFD area. Translational Relevance These findings provide new insights on gaze adaptations in patients with HVFDs during activities of daily living and will enhance the design and development of realistic examination tools for use in the clinical setting to improve daily functioning. (http://www.clinicaltrials.gov, NCT01372319, NCT01372332) PMID:25374771

  8. An introduction to DARC technology.

    PubMed

    Ahmad, Syed Shoeb

    2017-01-01

    Glaucoma is a multi-factorial neurodegenerative disorder. The common denominator in all types of glaucomas is retinal ganglion cell death through apoptosis. However, this cellular demise in glaucoma is detected late by structural or functional analyses. There can be a 10-year delay prior to the appearance of visual field defects and pre-perimetric glaucoma is an issue still being addressed. However, a new cutting-edge technology called detection of apoptosing retinal cells (DARC) is being developed. This technique is capable of non-invasive, real-time visualization of apoptotic changes at the cellular level. It can detect glaucomatous cell damage at a very early stage, at the moment apoptosis starts, and thus management can be initiated even prior to development of visual field changes. In future, this technique will also be able to provide conclusive evidence of the effectiveness of treatment protocol and the need for any modifications which may be required. This article aims to provide a concise review of DARC technology.

  9. Role of Visual Feedback Treatment for Defective /s/ Sounds in Patients with Cleft Palate.

    ERIC Educational Resources Information Center

    Michi, Ken-ichi; And Others

    1993-01-01

    Six patients with cleft palate were provided treatment using either visual feedback for tongue placement and frication or no visual feedback. Results indicated the feedback was especially useful in the treatment of defective /s/ sounds in the patients who exhibited abnormal posterior tongue posturing during dental or alveolar sounds. (Author/DB)

  10. The idiopathic intracranial hypertension treatment trial: clinical profile at baseline.

    PubMed

    Wall, Michael; Kupersmith, Mark J; Kieburtz, Karl D; Corbett, James J; Feldon, Steven E; Friedman, Deborah I; Katz, David M; Keltner, John L; Schron, Eleanor B; McDermott, Michael P

    2014-06-01

    To our knowledge, there are no large prospective cohorts of untreated patients with idiopathic intracranial hypertension (IIH) to characterize the disease. To report the baseline clinical and laboratory features of patients enrolled in the Idiopathic Intracranial Hypertension Treatment Trial. We collected data at baseline from questionnaires, examinations, automated perimetry, and fundus photography grading. Patients (n = 165) were enrolled from March 17, 2010, to November 27, 2012, at 38 academic and private practice sites in North America. All participants met the modified Dandy criteria for IIH and had a perimetric mean deviation between -2 dB and -7 dB. All but 4 participants were women. Baseline and laboratory characteristics. The mean (SD) age of our patients was 29.0 (7.4) years and 4 (2.4%) were men. The average (SD) body mass index (calculated as weight in kilograms divided by height in meters squared) was 39.9 (8.3). Headache was the most common symptom (84%). Transient visual obscurations occurred in 68% of patients, back pain in 53%, and pulse synchronous tinnitus in 52%. Only 32% reported visual loss. The average (SD) perimetric mean deviation in the worst eye was -3.5 (1.1) dB, (range, -2.0 to -6.4 dB) and in the best eye was -2.3 (1.1) dB (range, -5.2 to 0.8 dB). A partial arcuate visual field defect with an enlarged blind spot was the most common perimetric finding. Visual acuity was 85 letters or better (20/20) in 71% of the worst eyes and 77% of the best eyes. Quality of life measures, including the National Eye Institute Visual Function Questionnaire-25 and the Short Form-36 physical and mental health summary scales, were lower compared with population norms. The Idiopathic Intracranial Hypertension Treatment Trial represents the largest prospectively analyzed cohort of untreated patients with IIH. Our data show that IIH is almost exclusively a disease of obese young women. Patients with IIH with mild visual loss have typical symptoms, may have mild acuity loss, and have visual field defects, with predominantly arcuate loss and enlarged blind spots that require formal perimetry for detection. clinicaltrials.gov Identifier: NCT01003639.

  11. Low-frequency nondestructive analysis of cracks in multilayer structures using a scanning magnetic microscope

    NASA Astrophysics Data System (ADS)

    Adamo, M.; Nappi, C.; Sarnelli, E.

    2010-09-01

    The use of a scanning magnetic microscope (SMM) with a high temperature superconducting quantum interference device (SQUID) for quantitative measurements in eddy current nondestructive analysis (NDA) is presented. The SQUID has been used to detect the weak magnetic field variations around a small defect, close to a structural part generating an intensive magnetic field. The experimental data for a deep crack close to a rivet in a multilayer conducting plate have been taken in a RF-shielded environment and discussed in the light of the theoretical predictions. The results show that eddy current NDA can distinguish subsurface crack signals from wider structural signals, with defects located 10 mm below the surface. Moreover, in order to visualize the structure of the probing current when a circular induction coil is used, the simulation of eddy currents in a thick unflawed conducting plate has been carried out.

  12. Reducing Spatial Uncertainty Through Attentional Cueing Improves Contrast Sensitivity in Regions of the Visual Field With Glaucomatous Defects

    PubMed Central

    Phu, Jack; Kalloniatis, Michael; Khuu, Sieu K.

    2018-01-01

    Purpose Current clinical perimetric test paradigms present stimuli randomly to various locations across the visual field (VF), inherently introducing spatial uncertainty, which reduces contrast sensitivity. In the present study, we determined the extent to which spatial uncertainty affects contrast sensitivity in glaucoma patients by minimizing spatial uncertainty through attentional cueing. Methods Six patients with open-angle glaucoma and six healthy subjects underwent laboratory-based psychophysical testing to measure contrast sensitivity at preselected locations at two eccentricities (9.5° and 17.5°) with two stimulus sizes (Goldmann sizes III and V) under different cueing conditions: 1, 2, 4, or 8 points verbally cued. Method of Constant Stimuli and a single-interval forced-choice procedure were used to generate frequency of seeing (FOS) curves at locations with and without VF defects. Results At locations with VF defects, cueing minimizes spatial uncertainty and improves sensitivity under all conditions. The effect of cueing was maximal when one point was cued, and rapidly diminished when more points were cued (no change to baseline with 8 points cued). The slope of the FOS curve steepened with reduced spatial uncertainty. Locations with normal sensitivity in glaucomatous eyes had similar performance to that of healthy subjects. There was a systematic increase in uncertainty with the depth of VF loss. Conclusions Sensitivity measurements across the VF are negatively affected by spatial uncertainty, which increases with greater VF loss. Minimizing uncertainty can improve sensitivity at locations of deficit. Translational Relevance Current perimetric techniques introduce spatial uncertainty and may therefore underestimate sensitivity in regions of VF loss. PMID:29600116

  13. Progression of Patterns (POP): A Machine Classifier Algorithm to Identify Glaucoma Progression in Visual Fields

    PubMed Central

    Goldbaum, Michael H.; Lee, Intae; Jang, Giljin; Balasubramanian, Madhusudhanan; Sample, Pamela A.; Weinreb, Robert N.; Liebmann, Jeffrey M.; Girkin, Christopher A.; Anderson, Douglas R.; Zangwill, Linda M.; Fredette, Marie-Josee; Jung, Tzyy-Ping; Medeiros, Felipe A.; Bowd, Christopher

    2012-01-01

    Purpose. We evaluated Progression of Patterns (POP) for its ability to identify progression of glaucomatous visual field (VF) defects. Methods. POP uses variational Bayesian independent component mixture model (VIM), a machine learning classifier (MLC) developed previously. VIM separated Swedish Interactive Thresholding Algorithm (SITA) VFs from a set of 2,085 normal and glaucomatous eyes into nine axes (VF patterns): seven glaucomatous. Stable glaucoma was simulated in a second set of 55 patient eyes with five VFs each, collected within four weeks. A third set of 628 eyes with 4,186 VFs (mean ± SD of 6.7 ± 1.7 VFs over 4.0 ± 1.4 years) was tested for progression. Tested eyes were placed into suspect and glaucoma categories at baseline, based on VFs and disk stereoscopic photographs; a subset of eyes had stereophotographic evidence of progressive glaucomatous optic neuropathy (PGON). Each sequence of fields was projected along seven VIM glaucoma axes. Linear regression (LR) slopes generated from projections onto each axis yielded a degree of confidence (DOC) that there was progression. At 95% specificity, progression cutoffs were established for POP, visual field index (VFI), and mean deviation (MD). Guided progression analysis (GPA) was also compared. Results. POP identified a statistically similar number of eyes (P > 0.05) as progressing compared with VFI, MD, and GPA in suspects (3.8%, 2.7%, 5.6%, and 2.9%, respectively), and more eyes than GPA (P = 0.01) in glaucoma (16.0%, 15.3%, 12.0%, and 7.3%, respectively), and more eyes than GPA (P = 0.05) in PGON eyes (26.3%, 23.7%, 27.6%, and 14.5%, respectively). Conclusions. POP, with its display of DOC of progression and its identification of progressing VF defect pattern, adds to the information available to the clinician for detecting VF progression. PMID:22786913

  14. Information support of monitoring of technical condition of buildings in construction risk area

    NASA Astrophysics Data System (ADS)

    Skachkova, M. E.; Lepihina, O. Y.; Ignatova, V. V.

    2018-05-01

    The paper presents the results of the research devoted to the development of a model of information support of monitoring buildings technical condition; these buildings are located in the construction risk area. As a result of the visual and instrumental survey, as well as the analysis of existing approaches and techniques, attributive and cartographic databases have been created. These databases allow monitoring defects and damages of buildings located in a 30-meter risk area from the object under construction. The classification of structures and defects of these buildings under survey is presented. The functional capabilities of the developed model and the field of it practical applications are determined.

  15. Computed tomographic identification of calcified optic nerve drusen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez, H.; Blatt, E.S.; Hibri, N.S.

    1983-07-01

    Four cases of optic disk drusen were accurately diagnosed with orbital computed tomography (CT). The radiologist should be aware of the characteristic CT finding of discrete calcification within an otherwise normal optic disk. This benign process is easily differentiated from lesions such as calcific neoplastic processes of the posterior globe. CT identification of optic disk drusen is essential in the evaluation of visual field defects, migraine-like headaches, and pseudopapilledema.

  16. Contralateral eye comparison on changes in visual field following laser in situ keratomileusis vs photorefractive keratectomy for myopia: a randomized clinical trial.

    PubMed

    Mostafaei, A; Sedgipour, M R; Sadeghi-Bazargani, H

    2009-12-01

    Study purpose was to compare the changes of Visual Field (VF) during laser in situ Keratomileusis (LASIK) VS photorefractive keratectomy (PRK). This randomized, double blind, study involved 54 eyes of 27 Myopia patients who underwent LASIK or PRK procedures for contralateral eyes in each patient. Using Humphrey 30-2 SITA standard, the Mean Defect (MD) and Pattern Standard Deviation (PSD) were evaluated preoperatively and three months after surgery. At the same examination optical zone size, papillary and corneal diameters were also evaluated. There was no clinically significant difference in PSD and MD measurements between treated eyes with LASIK or PRK in any zone pre and postoperatively. VF may not be affected by corneal changes induced by LASIK or PRK three months after surgery.

  17. A Sticky Situation.

    PubMed

    Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq

    2018-04-26

    An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. How does glaucoma look?: patient perception of visual field loss.

    PubMed

    Crabb, David P; Smith, Nicholas D; Glen, Fiona C; Burton, Robyn; Garway-Heath, David F

    2013-06-01

    To explore patient perception of vision loss in glaucoma and, specifically, to test the hypothesis that patients do not recognize their impairment as a black tunnel effect or as black patches in their field of view. Clinic-based cross-sectional study. Fifty patients (age range, 52-82 years) with visual acuity better than 20/30 and with a range of glaucomatous visual field (VF) defects in both eyes, excluding those with very advanced disease (perimetrically blind). Participants underwent monocular VF testing in both eyes using a Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA; 24-2 Swedish interactive threshold algorithm standard tests) and other tests of visual function. Participants took part in a recorded interview during which they were asked if they were aware of their VF loss; if so, there were encouraged to describe it in their own words. Participants were shown 6 images modified in a variety of ways on a computer monitor and were asked to select the image that most closely represented their perception of their VF loss. Forced choice of an image best representing glaucomatous vision impairment. Participants had a range of VF defect severity: average HFA mean deviation was -8.7 dB (standard deviation [SD], 5.8 dB) and -10.5 dB (SD, 7.1 dB) in the right and left eyes, respectively. Thirteen patients (26%; 95% confidence interval [CI], 15%-40%) reported being completely unaware of their vision loss. None of the patients chose the images with a distinct black tunnel effect or black patches. Only 2 patients (4%; 95% CI, 0%-14%) chose the image with a tunnel effect with blurred edges. An image depicting blurred patches and another with missing patches was chosen by 54% (95% CI, 39%-68%) and 16% (95% CI, 7%-29%) of the patients, respectively. Content analysis of the transcripts from the recorded interviews indicated a frequent use of descriptors of visual symptoms associated with reported blur and missing features. Patients with glaucoma do not perceive their vision loss as a black tunnel effect or as black patches masking their field of view. These findings are important in the context of depicting the effects of glaucomatous vision loss and raising awareness for glaucoma detection. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Accuracy and Feasibility of an Android-Based Digital Assessment Tool for Post Stroke Visual Disorders-The StrokeVision App.

    PubMed

    Quinn, Terence J; Livingstone, Iain; Weir, Alexander; Shaw, Robert; Breckenridge, Andrew; McAlpine, Christine; Tarbert, Claire M

    2018-01-01

    Visual impairment affects up to 70% of stroke survivors. We designed an app (StrokeVision) to facilitate screening for common post stroke visual issues (acuity, visual fields, and visual inattention). We sought to describe the test time, feasibility, acceptability, and accuracy of our app-based digital visual assessments against (a) current methods used for bedside screening and (b) gold standard measures. Patients were prospectively recruited from acute stroke settings. Index tests were app-based assessments of fields and inattention performed by a trained researcher. We compared against usual clinical screening practice of visual fields to confrontation, including inattention assessment (simultaneous stimuli). We also compared app to gold standard assessments of formal kinetic perimetry (Goldman or Octopus Visual Field Assessment); and pencil and paper-based tests of inattention (Albert's, Star Cancelation, and Line Bisection). Results of inattention and field tests were adjudicated by a specialist Neuro-ophthalmologist. All assessors were masked to each other's results. Participants and assessors graded acceptability using a bespoke scale that ranged from 0 (completely unacceptable) to 10 (perfect acceptability). Of 48 stroke survivors recruited, the complete battery of index and reference tests for fields was successfully completed in 45. Similar acceptability scores were observed for app-based [assessor median score 10 (IQR: 9-10); patient 9 (IQR: 8-10)] and traditional bedside testing [assessor 10 (IQR: 9-10); patient 10 (IQR: 9-10)]. Median test time was longer for app-based testing [combined time to completion of all digital tests 420 s (IQR: 390-588)] when compared with conventional bedside testing [70 s, (IQR: 40-70)], but shorter than gold standard testing [1,260 s, (IQR: 1005-1,620)]. Compared with gold standard assessments, usual screening practice demonstrated 79% sensitivity and 82% specificity for detection of a stroke-related field defect. This compares with 79% sensitivity and 88% specificity for StrokeVision digital assessment. StrokeVision shows promise as a screening tool for visual complications in the acute phase of stroke. The app is at least as good as usual screening and offers other functionality that may make it attractive for use in acute stroke. https://ClinicalTrials.gov/ct2/show/NCT02539381.

  20. Visual field defects and retinal nerve fiber imaging in patients with obstructive sleep apnea syndrome and in healthy controls.

    PubMed

    Casas, Paula; Ascaso, Francisco J; Vicente, Eugenio; Tejero-Garcés, Gloria; Adiego, María I; Cristóbal, José A

    2018-03-02

    To assess the retinal sensitivity in obstructive sleep apnea hypopnea syndrome (OSAHS) patients evaluated with standard automated perimetry (SAP). And to correlate the functional SAP results with structural parameters obtained with optical coherence tomography (OCT). This prospective, observational, case-control study consisted of 63 eyes of 63 OSAHS patients (mean age 51.7 ± 12.7 years, best corrected visual acuity ≥20/25, refractive error less than three spherical or two cylindrical diopters, and intraocular pressure < 21 mmHg) who were enrolled and compared with 38 eyes of 38 age-matched controls. Peripapillary retinal nerve fiber layer (RNFL) thickness was measured by Stratus OCT and SAP sensitivities and indices were explored with Humphrey Field Analyzer perimeter. Correlations between functional and structural parameters were calculated, as well as the relationship between ophthalmologic and systemic indices in OSAHS patients. OSAHS patients showed a significant reduction of the sensitivity for superior visual field division (p = 0.034, t-student test). When dividing the OSAHS group in accordance with the severity of the disease, nasal peripapillary RNFL thickness was significantly lower in severe OSAHS than that in controls and mild-moderate cases (p = 0.031 and p = 0.016 respectively, Mann-Whitney U test). There were no differences between groups for SAP parameters. We found no correlation between structural and functional variables. The central visual field sensitivity of the SAP revealed a poor Pearson correlation with the apnea-hipopnea index (0.284, p = 0.024). Retinal sensitivity show minor differences between healthy subjects and OSAHS. Functional deterioration in OSAHS patients is not easy to demonstrate with visual field examination.

  1. Neural attractor network for application in visual field data classification.

    PubMed

    Fink, Wolfgang

    2004-07-07

    The purpose was to introduce a novel method for computer-based classification of visual field data derived from perimetric examination, that may act as a 'counsellor', providing an independent 'second opinion' to the diagnosing physician. The classification system consists of a Hopfield-type neural attractor network that obtains its input data from perimetric examination results. An iterative relaxation process determines the states of the neurons dynamically. Therefore, even 'noisy' perimetric output, e.g., early stages of a disease, may eventually be classified correctly according to the predefined idealized visual field defect (scotoma) patterns, stored as attractors of the network, that are found with diseases of the eye, optic nerve and the central nervous system. Preliminary tests of the classification system on real visual field data derived from perimetric examinations have shown a classification success of over 80%. Some of the main advantages of the Hopfield-attractor-network-based approach over feed-forward type neural networks are: (1) network architecture is defined by the classification problem; (2) no training is required to determine the neural coupling strengths; (3) assignment of an auto-diagnosis confidence level is possible by means of an overlap parameter and the Hamming distance. In conclusion, the novel method for computer-based classification of visual field data, presented here, furnishes a valuable first overview and an independent 'second opinion' in judging perimetric examination results, pointing towards a final diagnosis by a physician. It should not be considered a substitute for the diagnosing physician. Thanks to the worldwide accessibility of the Internet, the classification system offers a promising perspective towards modern computer-assisted diagnosis in both medicine and tele-medicine, for example and in particular, with respect to non-ophthalmic clinics or in communities where perimetric expertise is not readily available.

  2. Retinal abnormalities in β-thalassemia major

    PubMed Central

    Bhoiwala, Devang L.; Dunaief, Joshua L.

    2015-01-01

    Patients with beta (β)-thalassemia (β-TM: thalassemia major, β-TI: thalassemia intermedia) have a variety of complications that may affect all organs, including the eye. Ocular abnormalities include retinal pigment epithelium degeneration, angioid streaks, venous tortuosity, night blindness, visual field defects, decreased visual acuity, color vision abnormalities, and acute visual loss. Patients with β-TM are transfusion dependent and require iron chelation therapy (ICT) in order to survive. Retinal degeneration may result from either retinal iron accumulation from transfusion-induced iron overload or retinal toxicity induced by ICT. Some who were never treated with ICT exhibited retinopathy, and others receiving ICT had chelator-induced retinopathy. We will focus on retinal abnormalities present in individuals with β-TM viewed in light of new findings on the mechanisms and manifestations of retinal iron toxicity. PMID:26325202

  3. Properties of pattern standard deviation in open-angle glaucoma patients with hemi-optic neuropathy and bi-optic neuropathy.

    PubMed

    Heo, Dong Won; Kim, Kyoung Nam; Lee, Min Woo; Lee, Sung Bok; Kim, Chang-Sik

    2017-01-01

    To evaluate the properties of pattern standard deviation (PSD) according to localization of the glaucomatous optic neuropathy. We enrolled 242 eyes of 242 patients with primary open-angle glaucoma, with a best-corrected visual acuity ≥ 20/25, and no media opacity. Patients were examined via dilated fundus photography, spectral-domain optical coherence tomography, and Humphrey visual field examination, and divided into those with hemi-optic neuropathy (superior or inferior) and bi-optic neuropathy (both superior and inferior). We assessed the relationship between mean deviation (MD) and PSD. Using broken stick regression analysis, the tipping point was identified, i.e., the point at which MD became significantly associated with a paradoxical reversal of PSD. In 91 patients with hemi-optic neuropathy, PSD showed a strong correlation with MD (r = -0.973, β = -0.965, p < 0.001). The difference between MD and PSD ("-MD-PSD") was constant (mean, -0.32 dB; 95% confidence interval, -2.48~1.84 dB) regardless of visual field defect severity. However, in 151 patients with bi-optic neuropathy, a negative correlation was evident between "-MD-PSD" and MD (r2 = 0.907, p < 0.001). Overall, the MD tipping point was -14.0 dB, which was close to approximately 50% damage of the entire visual field (p < 0.001). Although a false decrease of PSD usually begins at approximately 50% visual field damage, in patients with hemi-optic neuropathy, the PSD shows no paradoxical decrease and shows a linear correlation with MD.

  4. How Many Subjects are Needed for a Visual Field Normative Database? A Comparison of Ground Truth and Bootstrapped Statistics.

    PubMed

    Phu, Jack; Bui, Bang V; Kalloniatis, Michael; Khuu, Sieu K

    2018-03-01

    The number of subjects needed to establish the normative limits for visual field (VF) testing is not known. Using bootstrap resampling, we determined whether the ground truth mean, distribution limits, and standard deviation (SD) could be approximated using different set size ( x ) levels, in order to provide guidance for the number of healthy subjects required to obtain robust VF normative data. We analyzed the 500 Humphrey Field Analyzer (HFA) SITA-Standard results of 116 healthy subjects and 100 HFA full threshold results of 100 psychophysically experienced healthy subjects. These VFs were resampled (bootstrapped) to determine mean sensitivity, distribution limits (5th and 95th percentiles), and SD for different ' x ' and numbers of resamples. We also used the VF results of 122 glaucoma patients to determine the performance of ground truth and bootstrapped results in identifying and quantifying VF defects. An x of 150 (for SITA-Standard) and 60 (for full threshold) produced bootstrapped descriptive statistics that were no longer different to the original distribution limits and SD. Removing outliers produced similar results. Differences between original and bootstrapped limits in detecting glaucomatous defects were minimized at x = 250. Ground truth statistics of VF sensitivities could be approximated using set sizes that are significantly smaller than the original cohort. Outlier removal facilitates the use of Gaussian statistics and does not significantly affect the distribution limits. We provide guidance for choosing the cohort size for different levels of error when performing normative comparisons with glaucoma patients.

  5. Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.

    PubMed

    Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath

    2017-01-01

    To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.

  6. Epidemiology, clinical presentation and diagnosis of non-functioning pituitary adenomas.

    PubMed

    Ntali, Georgia; Wass, John A

    2018-04-01

    Non-functioning pituitary adenomas (NFPAs) are benign pituitary neoplasms that do not cause a hormonal hypersecretory syndrome. An improved understanding of their epidemiology, clinical presentation and diagnosis is needed. A literature review was performed using Pubmed to identify research reports and clinical case series on NFPAs. They account for 14-54% of pituitary adenomas and have a prevalence of 7-41.3/100,000 population. Their standardized incidence rate is 0.65-2.34/100,000 and the peak occurence is from the fourth to the eighth decade. The clinical spectrum of NFPAs varies from being completely asymptomatic to causing significant hypothalamic/pituitary dysfunction and visual field compromise due to their large size. Most patients present with symptoms of mass effect, such as headaches, visual field defects, ophthalmoplegias, and hypopituitarism but also hyperprolactinaemia due to pituitary stalk deviation and less frequently pituitary apoplexy. Non-functioning pituitary incidentalomas are found on brain imaging performed for an unrelated reason. Diagnostic approach includes magnetic resonance imaging of the sellar region, laboratory evaluations, screening for hormone hypersecretion and for hypopituitarism, and a visual field examination if the lesion abuts the optic nerves or chiasm. This article reviews the epidemiology, clinical behaviour and diagnostic approach of non-functioning pituitary adenomas.

  7. Central serous retinopathy with permanent visual deficit in a commercial air transport pilot: a case report.

    PubMed

    Newman, David G

    2002-11-01

    This report describes a case of central serous retinopathy (CSR) in the right eye of a commercial air transport pilot which resulted in a permanent reduction in visual acuity and the loss of his license. The previously fit and well pilot developed sudden loss of central vision, which resolved spontaneously. He then went on to experience recurrent episodes of fluctuating visual acuity (down to 6/60) and visual dysfunction in the right eye. His left eye remained unaffected. Eventually his condition stabilized, and he was left with a permanent reduction in right visual acuity (6/36) with intact peripheral visual fields and a completely normal left eye. After a period of grounding of 12 mo, he sought to have his license reinstated. He was considered to be a functionally monocular pilot, and as such was granted a conditional Class 1 medical category. The aeromedical disposition of this pilot and the issues involved in determining the fitness to fly of pilots with permanent visual defects arising from CSR are discussed.

  8. The 1980 and 1981 accident experience of civil airmen with selected visual pathology.

    DOT National Transportation Integrated Search

    1983-07-01

    In studies of the 1974-76 accident experience of U.S. general aviation pilots with static physical defects, all the significantly increased rates and ratios were for visual defect categories--blindness, or absence of either eye, deficient distant vis...

  9. Individual analysis of inter and intragrain defects in electrically characterized polycrystalline silicon nanowire TFTs by multicomponent dark-field imaging based on nanobeam electron diffraction two-dimensional mapping

    NASA Astrophysics Data System (ADS)

    Asano, Takanori; Takaishi, Riichiro; Oda, Minoru; Sakuma, Kiwamu; Saitoh, Masumi; Tanaka, Hiroki

    2018-04-01

    We visualize the grain structures for individual nanosized thin film transistors (TFTs), which are electrically characterized, with an improved data processing technique for the dark-field image reconstruction of nanobeam electron diffraction maps. Our individual crystal analysis gives the one-to-one correspondence of TFTs with different grain boundary structures, such as random and coherent boundaries, to the characteristic degradations of ON-current and threshold voltage. Furthermore, the local crystalline uniformity inside a single grain is detected as the difference in diffraction intensity distribution.

  10. A Portable Platform for Evaluation of Visual Performance in Glaucoma Patients

    PubMed Central

    Rosen, Peter N.; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Marvasti, Amir H.; Medeiros, Felipe A.

    2015-01-01

    Purpose To propose a new tablet-enabled test for evaluation of visual performance in glaucoma, the PERformance CEntered Portable Test (PERCEPT), and to evaluate its ability to predict history of falls and motor vehicle crashes. Design Cross-sectional study. Methods The study involved 71 patients with glaucomatous visual field defects on standard automated perimetry (SAP) and 59 control subjects. The PERCEPT was based on the concept of increasing visual task difficulty to improve detection of central visual field losses in glaucoma patients. Subjects had to perform a foveal 8-alternative-forced-choice orientation discrimination task, while detecting a simultaneously presented peripheral stimulus within a limited presentation time. Subjects also underwent testing with the Useful Field of View (UFOV) divided attention test. The ability to predict history of motor vehicle crashes and falls was investigated by odds ratios and incident-rate ratios, respectively. Results When adjusted for age, only the PERCEPT processing speed parameter showed significantly larger values in glaucoma compared to controls (difference: 243ms; P<0.001). PERCEPT results had a stronger association with history of motor vehicle crashes and falls than UFOV. Each 1 standard deviation increase in PERCEPT processing speed was associated with an odds ratio of 2.69 (P = 0.003) for predicting history of motor vehicle crashes and with an incident-rate ratio of 1.95 (P = 0.003) for predicting history of falls. Conclusion A portable platform for testing visual function was able to detect functional deficits in glaucoma, and its results were significantly associated with history of involvement in motor vehicle crashes and history of falls. PMID:26445501

  11. Ocular Problems of the Aging Military Aviator

    DTIC Science & Technology

    2000-08-01

    disposition. This might be grounding, further treatment , a waiver to return to flight status or change in flight status. (1) TABLE 2. DIAGNOSES AND...advancements in medicine and science since 1959, when Uveitis iritis 3 The Age 60 (2) rule came into being, had any effect on Optic neuritis/ischemnic...glaucoma with visual a diagnosis of glaucoma was a reason for commencing field defects 1 drug treatment of the disease. This was usually with Trauma

  12. Nano- and micro-scale Bi-substituted iron garnet films for photonics and magneto-optic eddy current defectoscopy

    NASA Astrophysics Data System (ADS)

    Berzhansky, V. N.; Karavainikov, A. V.; Mikhailova, T. V.; Prokopov, A. R.; Shaposhnikov, A. N.; Shumilov, A. G.; Lugovskoy, N. V.; Semuk, E. Yu.; Kharchenko, M. F.; Lukienko, I. M.; Kharchenko, Yu. M.; Belotelov, V. I.

    2017-10-01

    Synthesis technology of nano-scale Bi-substituted iron garnets films with high magneto-optic activity for photonics and plasmonics applications were proposed. The micro-scale single-crystal garnet films with different types of magnetic anisotropy as a magneto-optic sensors were synthesized. It was shown that easy-axis anisotropy films demonstrated the best results for visualization of redistribution eddy current magnetic field near defects.

  13. Vision-related quality of life in first stroke patients with homonymous visual field defects

    PubMed Central

    2010-01-01

    Background To evaluate vision-related and health-related quality of life (VRQoL, HRQoL) in first stroke patients with homonymous visual field defects (VFD) with respect to the extent of the lesion. Since VFD occur in approximately 10% of stroke patients the main purpose of the study was to investigate the additional impact of VFD in stroke patients hypothesizing that VFD causes diminished VRQoL. Methods In 177 first stroke patients with persisting VFD 2.5 years after posterior-parietal lesions VRQoL was assessed by the National-Eye-Institute-Visual-Functioning-Questionnaire (NEI-VFQ) and HRQoL by the Medical-Outcome-Study Short-Form-36 Health-Survey (SF-36). Questionnaire results of VFD-patients were compared with age- and sex-matched healthy controls and with general non-selected stroke samples as published elsewhere. VFD-type and visual acuity were partially correlated with questionnaire results. Results Compared to healthy controls VFD-patients had lower NEI-VFQ scores except ocular pain (Z-range -11.34 to -3.35) and lower SF-36 scores except emotional role limitations (Z-range -7.21 to -3.34). VFD-patients were less impaired in SF-36 scores than general stroke patients one month post lesion (6/8 subscales) but had lower SF-36 scores compared to stroke patients six months post lesion (5/8 subscales). Visual acuity significantly correlated with NEI-VFQ scores (r-range 0.27 to 0.48) and VFD-type with SF-36 mental subscales (r-range -0.26 to -0.36). Conclusions VFD-patients showed substantial reductions of VRQoL and HRQoL compared to healthy normals, but better HRQoL compared to stroke patients one month post lesion. VFD-patients (although their lesion age was four times higher) had significantly lower HRQoL than a general stroke population at six months post-stroke. This indicates that the stroke-related subjective level of HRQoL impairment is significantly exacerbated by VFD. While VRQoL was primarily influenced by visual acuity, mental components of HRQoL were influenced by VFD-type with larger VFD being associated with more distress. PMID:20346125

  14. 75 FR 54915 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-Sensory System...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... DEPARTMENT OF JUSTICE Antitrust Division Notice Pursuant to the National Cooperative Research and Production Act of 1993--Sensory System for Critical Infrastructure Defect Recognition, Visualization and... Critical Infrastructure Defect Recognition, Visualization and Failure Prediction ('Sensory System'') has...

  15. [Clinical feature of chronic compressive optic neuropathy without optic atrophy].

    PubMed

    Jiang, Libin; Shi, Jitong; Liu, Wendong; Kang, Jun; Wang, Ningli

    2014-12-01

    To investigate the clinical feature of the chronic compressive optic neuropathy without optic atrophy. Retrospective cases series study. The clinical data of 25 patients (37 eyes) with chronic compressive optic neuropathy without optic atrophy, treated in Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, from October, 2005 to March, 2014, were collected. Those patients had been showing visual symptoms for 6 months or longer, but missed diagnosed or misdiagnosed as other eye diseases due to their normal or slightly changed fundi. The collected data including visual acuities, visual fields, neuroimaging and/or pathologic diagnosis were analyzed. Among the 25 patients, there were 5 males and 20 females, and their ages range from 9 to 74 years [average (47.5 ± 13.4) years]. All patients suffered progressive impaired vision in single eye or both eyes, without exophthalmos or abnormal eye movements. Except one patient had a headache, other patients did not show systemic symptoms. The corrected visual acuities were between HM to 1.0, and their appearances of optic discs and colors of fundi were normal. After neuroimaging and/or pathological examination, it was proven that 14 patients suffered tuberculum sellae meningiomas, 5 patients with hypophysoma, 3 patient with optic nerve sheath meningioma in orbital apex, 1 patient with cavernous hemangioma, 1 patient with vascular malformation in orbital apex and 1 patient with optic nerve glioma. Among the 19 patients whose suffered occupied lesions of saddle area, 14 patients underwent visual field examinations, and only 4 patients showed classic visual field defects caused by optic chiasmal lesions. Occult progressive visual loss was the most important clinical feature of the disease.

  16. Unilateral retinitis pigmentosa occurring in an individual with a mutation in the CLRN1 gene.

    PubMed

    Sim, Peng Yong; Jeganathan, V Swetha E; Wright, Alan F; Cackett, Peter

    2018-03-15

    This case report depicts the clinical course of a female patient with unilateral retinitis pigmentosa, who first presented at the age of 12 years. Fundus photography at the time revealed unilateral pigmentary retinopathy, which was associated with extinguished electroretinogram (ERG) signal. At 35 years of age, fundus examination revealed deterioration of pre-existing unilateral pigmentary retinopathy with progressive visual field defect detected on Goldmann visual field testing. ERG findings remained unchanged and multifocal ERG showed unilateral decrease in amplitude in the affected eye. The patient was referred for genetic counselling. Next-generation sequencing identified a deleterious heterozygous c.118T>G (p.Cys40Gly) mutation in the CLRN1 gene. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Echocardiographic detection of ventricular septal defects in large animals.

    PubMed

    Pipers, F S; Reef, V; Wilson, J

    1985-10-15

    Ventricular septal defects in a foal, a 2-year-old filly, and 2 calves were demonstrated with M-mode and two-dimensional real-time echocardiography. The studies were performed with the animals unsedated, either standing or in lateral recumbency. Cardiac windows were located between the 4th and 7th intercostal spaces, approximately at the level of the olecranon. In each case, the septal defect was visualized high in the membranous portion of the interventricular septum. Defects were visualized by use of sector scanning or linear-array ultrasonic equipment, with transducer frequencies of 2.25 to 3.5 MHz.

  18. Detecting wood surface defects with fusion algorithm of visual saliency and local threshold segmentation

    NASA Astrophysics Data System (ADS)

    Wang, Xuejuan; Wu, Shuhang; Liu, Yunpeng

    2018-04-01

    This paper presents a new method for wood defect detection. It can solve the over-segmentation problem existing in local threshold segmentation methods. This method effectively takes advantages of visual saliency and local threshold segmentation. Firstly, defect areas are coarsely located by using spectral residual method to calculate global visual saliency of them. Then, the threshold segmentation of maximum inter-class variance method is adopted for positioning and segmenting the wood surface defects precisely around the coarse located areas. Lastly, we use mathematical morphology to process the binary images after segmentation, which reduces the noise and small false objects. Experiments on test images of insect hole, dead knot and sound knot show that the method we proposed obtains ideal segmentation results and is superior to the existing segmentation methods based on edge detection, OSTU and threshold segmentation.

  19. Probing glaucoma visual damage by rarebit perimetry.

    PubMed

    Brusini, P; Salvetat, M L; Parisi, L; Zeppieri, M

    2005-02-01

    To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluated using Student-Newman-Keuls and chi(2) tests. Correlation between HFA and RBP parameters was assessed using the Pearson's correlation coefficients and regression analysis. Sensitivity and specificity of RBP in detecting early glaucomatous visual damage were calculated with different algorithms. RBP-mean hit rate (MHR) was respectively 88.6% (SD 4.8%) in controls; 79.1% (10.9%) in the OH group; 64.3% (13.8%) in the POAG group (differences statistically significant). Good correlation in the POAG group was found between HFA-mean deviation and RBP-MHR. Largest AROC (0.95) and optimal sensitivity (97.4%) were obtained when an abnormal RBP test was defined as having (at least 1): MHR <80%; >15 areas with a non-hit rate of >10%; > or =2 areas with a non-hit rate of >50%; at least one area with a non-hit rate of > or =70%. The RBP appeared to be a rapid, comfortable, and easily available perimetric test (requiring only a PC device), showing a high sensitivity and specificity in detecting early glaucomatous visual field defects.

  20. Porosity Defect Remodeling and Tensile Analysis of Cast Steel

    PubMed Central

    Sun, Linfeng; Liao, Ridong; Lu, Wei; Fu, Sibo

    2016-01-01

    Tensile properties on ASTM A216 WCB cast steel with centerline porosity defect were studied with radiographic mapping and finite element remodeling technique. Non-linear elastic and plastic behaviors dependent on porosity were mathematically described by relevant equation sets. According to the ASTM E8 tensile test standard, matrix and defect specimens were machined into two categories by two types of height. After applying radiographic inspection, defect morphologies were mapped to the mid-sections of the finite element models and the porosity fraction fields had been generated with interpolation method. ABAQUS input parameters were confirmed by trial simulations to the matrix specimen and comparison with experimental outcomes. Fine agreements of the result curves between simulations and experiments could be observed, and predicted positions of the tensile fracture were found to be in accordance with the tests. Chord modulus was used to obtain the equivalent elastic stiffness because of the non-linear features. The results showed that elongation was the most influenced term to the defect cast steel, compared with elastic stiffness and yield stress. Additional visual explanations on the tensile fracture caused by void propagation were also given by the result contours at different mechanical stages, including distributions of Mises stress and plastic strain. PMID:28787919

  1. Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects

    PubMed Central

    Swanson, William H.; Horner, Douglas G.; Dul, Mitchell W.; Malinovsky, Victor E.

    2014-01-01

    Purpose To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Methods Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Results Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively (F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively (P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower (P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Conclusions Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. Translational Relevance The guidelines should allow developers to choose from a wide range of stimuli. PMID:25371855

  2. Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects.

    PubMed

    Swanson, William H; Horner, Douglas G; Dul, Mitchell W; Malinovsky, Victor E

    2014-09-01

    To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively ( F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively ( P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower ( P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. The guidelines should allow developers to choose from a wide range of stimuli.

  3. System and process for detecting and monitoring surface defects

    NASA Technical Reports Server (NTRS)

    Mueller, Mark K. (Inventor)

    1994-01-01

    A system and process for detecting and monitoring defects in large surfaces such as the field joints of the container segments of a space shuttle booster motor. Beams of semi-collimated light from three non-parallel fiber optic light panels are directed at a region of the surface at non-normal angles of expected incidence. A video camera gathers some portion of the light that is reflected at an angle other than the angle of expected reflectance, and generates signals which are analyzed to discern defects in the surface. The analysis may be performed by visual inspection of an image on a video monitor, or by inspection of filtered or otherwise processed images. In one alternative embodiment, successive predetermined regions of the surface are aligned with the light source before illumination, thereby permitting efficient detection of defects in a large surface. Such alignment is performed by using a line scan gauge to sense the light which passes through an aperture in the surface. In another embodiment a digital map of the surface is created, thereby permitting the maintenance of records detailing changes in the location or size of defects as the container segment is refurbished and re-used. The defect detection apparatus may also be advantageously mounted on a fixture which engages the edge of a container segment.

  4. Evaluation of an attributive measurement system in the automotive industry

    NASA Astrophysics Data System (ADS)

    Simion, C.

    2016-08-01

    Measurement System Analysis (MSA) is a critical component for any quality improvement process. MSA is defined as an experimental and mathematical method of determining how much the variation within the measurement process contributes to overall process variability and it falls into two categories: attribute and variable. Most problematic measurement system issues come from measuring attribute data, which are usually the result of human judgment (visual inspection). Because attributive measurement systems are often used in some manufacturing processes, their assessment is important to obtain the confidence in the inspection process, to see where are the problems in order to eliminate them and to guide the process improvement. It was the aim of this paper to address such a issue presenting a case study made in a local company from the Sibiu region supplying products for the automotive industry, specifically the bag (a technical textile component, i.e. the fabric) for the airbag module. Because defects are inherent in every manufacturing process and in the field of airbag systems a minor defect can influence their performance and lives depend on the safety feature, there is a stringent visual inspection required on the defects of the bag material. The purpose of this attribute MSA was: to determine if all inspectors use the same criteria to determine “pass” from “fail” product (i.e. the fabric); to assess company inspection standards against customer's requirements; to determine how well inspectors are conforming to themselves; to identify how inspectors are conforming to a “known master,” which includes: how often operators ship defective product, how often operators dispose of acceptable product; to discover areas where training is required, procedures must be developed and standards are not available. The results were analyzed using MINITAB software with its module called Attribute Agreement Analysis. The conclusion was that the inspection process must be improved by operator training, developing visual aids/boundary samples, establishing standards and set-up procedures.

  5. Random waves in the brain: Symmetries and defect generation in the visual cortex

    NASA Astrophysics Data System (ADS)

    Schnabel, M.; Kaschube, M.; Löwel, S.; Wolf, F.

    2007-06-01

    How orientation maps in the visual cortex of the brain develop is a matter of long standing debate. Experimental and theoretical evidence suggests that their development represents an activity-dependent self-organization process. Theoretical analysis [1] exploring this hypothesis predicted that maps at an early developmental stage are realizations of Gaussian random fields exhibiting a rigorous lower bound for their densities of topological defects, called pinwheels. As a consequence, lower pinwheel densities, if observed in adult animals, are predicted to develop through the motion and annihilation of pinwheel pairs. Despite of being valid for a large class of developmental models this result depends on the symmetries of the models and thus of the predicted random field ensembles. In [1] invariance of the orientation map's statistical properties under independent space rotations and orientation shifts was assumed. However, full rotation symmetry appears to be broken by interactions of cortical neurons, e.g. selective couplings between groups of neurons with collinear orientation preferences [2]. A recently proposed new symmetry, called shift-twist symmetry [3], stating that spatial rotations have to occur together with orientation shifts in order to be an appropriate symmetry transformation, is more consistent with this organization. Here we generalize our random field approach to this important symmetry class. We propose a new class of shift-twist symmetric Gaussian random fields and derive the general correlation functions of this ensemble. It turns out that despite strong effects of the shift-twist symmetry on the structure of the correlation functions and on the map layout the lower bound on the pinwheel densities remains unaffected, predicting pinwheel annihilation in systems with low pinwheel densities.

  6. Nonarteritic anterior ischemic optic neuropathy following pars plana vitrectomy for macular hole treatment: case report.

    PubMed

    Cunha, Leonardo Provetti; Cunha, Luciana Virgínia Ferreira Costa; Costa, Carolina Ferreira; Monteiro, Mário Luiz Ribeiro

    2016-01-01

    Herein, we report a case of nonarteritic anterior ischemic optic neuropathy (NAION) following uneventful pars plana vitrectomy for macular hole treatment. A 56-year-old previously healthy woman presented with a full-thickness macular hole in right eye (OD) and small cup-to-disc ratios in both eyes. Five days after surgery, she noticed sudden painless loss of vision in OD and was found to have an afferent pupillary defect and intraocular pressure of 29 mmHg. Fundus examination showed right optic disc edema and the resolution of a macular hole with an inferior altitudinal visual field defect. Erythrocyte sedimentation rate, C-reactive protein levels, and general physical examination findings were normal. She was treated with hypotensive eyedrops and oral prednisone, resulting in mild visual improvement and a pale optic disc. A combination of face-down position and increased intraocular pressure due to a small optic disc cup were considered as potential mechanisms underlying NAION in the present case. Vitreoretinal surgeons should be aware of NAION as a potentially serious complication and be able to recognize associated risk factors and clinical findings.

  7. The advanced glaucoma intervention study, 6: effect of cataract on visual field and visual acuity. The AGIS Investigators.

    PubMed

    2000-12-01

    To investigate the effect of cataract on visual function and the role of cataract in explaining a race-treatment interaction in outcomes of glaucoma surgery. The Advanced Glaucoma Intervention Study (AGIS) enrolled 332 black patients (451 eyes) and 249 white patients (325 eyes) with advanced glaucoma. Eyes were randomly assigned to an argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy sequence or a trabeculectomy-ALT-trabeculectomy sequence. From the AGIS experience with cataract surgery during follow-up, we estimated the expected change in visual function scores from before cataract surgery to after cataract surgery. Then, for eyes with cataract not removed, we used these estimates of expected change to adjust visual function scores for the presumed effects of cataract. In turn, we used the adjusted scores to obtain cataract-adjusted main outcome measures. Average percent of eyes with decrease of visual field (APDVF) and average percent of eyes with decrease of visual acuity (APDVA). Within the 2 months before cataract surgery, visual acuity was better in eyes of white patients than of black patients by an average of approximately 2 lines on the visual acuity test chart. Cataract surgery improved visual acuity and visual field defect scores, with the amounts of improvement greater when preoperative visual acuity was lower. Adjustments for cataract brought about the following relative reductions: for APDVF, a relative reduction of 5% to 11% in black patients and 9% to 11% in white patients; for APDVA, a relative reduction of 45% to 49% in black patients and 31% to 38% in white patients; and for the APDVF and APDVA race-treatment interactions, relative reductions of 25% and 45%, respectively. On average, visual function scores improved after cataract surgery. The findings of reduced race-treatment interactions after adjustment for cataract do not alter our earlier conclusion that the AGIS 7-year results support use of the ALT-trabeculectomy-trabeculectomy sequence for black patients and of the trabeculectomy-ALT-trabeculectomy sequence for white patients without life-threatening health problems. The choice of treatment should take into account individual patient characteristics and needs.

  8. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    PubMed

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting.

  9. Columnar organization of orientation domains in V1

    NASA Astrophysics Data System (ADS)

    Liedtke, Joscha; Wolf, Fred

    In the primary visual cortex (V1) of primates and carnivores, the functional architecture of basic stimulus selectivities appears similar across cortical layers (Hubel & Wiesel, 1962) justifying the use of two-dimensional cortical models and disregarding organization in the third dimension. Here we show theoretically that already small deviations from an exact columnar organization lead to non-trivial three-dimensional functional structures. We extend two-dimensional random field models (Schnabel et al., 2007) to a three-dimensional cortex by keeping a typical scale in each layer and introducing a correlation length in the third, columnar dimension. We examine in detail the three-dimensional functional architecture for different cortical geometries with different columnar correlation lengths. We find that (i) topological defect lines are generally curved and (ii) for large cortical curvatures closed loops and reconnecting topological defect lines appear. This theory extends the class of random field models by introducing a columnar dimension and provides a systematic statistical assessment of the three-dimensional functional architecture of V1 (see also (Tanaka et al., 2011)).

  10. The Idiopathic Intracranial Hypertension Treatment Trial

    PubMed Central

    Wall, Michael; Kupersmith, Mark J.; Kieburtz, Karl D.; Corbett, James J.; Feldon, Steven E.; Friedman, Deborah I.; Katz, David M.; Keltner, John L.; Schron, Eleanor B.; McDermott, Michael P.

    2015-01-01

    IMPORTANCE To our knowledge, there are no large prospective cohorts of untreated patients with idiopathic intracranial hypertension (IIH) to characterize the disease. OBJECTIVE To report the baseline clinical and laboratory features of patients enrolled in the Idiopathic Intracranial Hypertension Treatment Trial. DESIGN, SETTING, AND PARTICIPANTS We collected data at baseline from questionnaires, examinations, automated perimetry, and fundus photography grading. Patients (n = 165) were enrolled from March 17, 2010, to November 27, 2012, at 38 academic and private practice sites in North America. All participants met the modified Dandy criteria for IIH and had a perimetric mean deviation between −2 dB and −7 dB. All but 4 participants were women. MAIN OUTCOMES AND MEASURES Baseline and laboratory characteristics. RESULTS The mean (SD) age of our patients was 29.0 (7.4) years and 4 (2.4%) were men. The average (SD) body mass index (calculated as weight in kilograms divided by height in meters squared) was 39.9 (8.3). Headache was the most common symptom (84%). Transient visual obscurations occurred in 68% of patients, back pain in 53%, and pulse synchronous tinnitus in 52%. Only 32% reported visual loss. The average (SD) perimetric mean deviation in the worst eye was −3.5 (1.1) dB, (range, −2.0 to −6.4 dB) and in the best eye was −2.3 (1.1) dB (range, −5.2 to 0.8 dB). A partial arcuate visual field defect with an enlarged blind spot was the most common perimetric finding. Visual acuity was 85 letters or better (20/20) in 71% of the worst eyes and 77% of the best eyes. Quality of life measures, including the National Eye Institute Visual Function Questionnaire–25 and the Short Form–36 physical and mental health summary scales, were lower compared with population norms. CONCLUSIONS AND RELEVANCE The Idiopathic Intracranial Hypertension Treatment Trial represents the largest prospectively analyzed cohort of untreated patients with IIH. Our data show that IIH is almost exclusively a disease of obese young women. Patients with IIH with mild visual loss have typical symptoms, may have mild acuity loss, and have visual field defects, with predominantly arcuate loss and enlarged blind spots that require formal perimetry for detection. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01003639 PMID:24756302

  11. Correspondence between retinotopic cortical mapping and conventional functional and morphological assessment of retinal disease.

    PubMed

    Ritter, Markus; Hummer, Allan; Ledolter, Anna A; Holder, Graham E; Windischberger, Christian; Schmidt-Erfurth, Ursula M

    2018-04-26

    The present study describes retinotopic mapping of the primary visual cortex using functional MRI (fMRI) in patients with retinal disease. It addresses the relationship between fMRI data and data obtained by conventional assessment including microperimetry (MP) and structural imaging. Initial testing involved eight patients with central retinal disease (Stargardt disease, STGD) and eight with peripheral retinal disease (retinitis pigmentosa, RP), who were examined using fMRI and MP (Nidek MP-1). All had a secure clinical diagnosis supported by electrophysiological data. fMRI used population-receptive field (pRF) mapping to provide retinotopic data that were then compared with the results of MP, optical coherence tomography and fundus autofluorescence imaging. Full analysis, following assessment of fMRI data reliability criteria, was performed in five patients with STGD and seven patients with RP; unstable fixation was responsible for unreliable pRF measurements in three patients excluded from final analysis. The macular regions in patients with STGD with central visual field defects and outer retinal atrophy (ORA) at the macula correlated well with pRF coverage maps showing reduced density of activated voxels at the occipital pole. Patients with RP exhibited peripheral ORA and concentric visual field defects both on MP and pRF mapping. Anterior V1 voxels, corresponding to peripheral regions, showed no significant activation. Correspondence between MP and pRF mapping was quantified by calculating the simple matching coefficient. Retinotopic maps acquired by fMRI provide a valuable adjunct in the assessment of retinal dysfunction. The addition of microperimetric data to pRF maps allowed better assessment of macular function than MP alone. Unlike MP, pRF mapping provides objective data independent of psychophysical perception from the patient. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.

    PubMed

    Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka

    2018-03-01

    To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.

  13. Image remapping strategies applied as protheses for the visually impaired

    NASA Technical Reports Server (NTRS)

    Johnson, Curtis D.

    1993-01-01

    Maculopathy and retinitis pigmentosa (rp) are two vision defects which render the afflicted person with impaired ability to read and recognize visual patterns. For some time there has been interest and work on the use of image remapping techniques to provide a visual aid for individuals with these impairments. The basic concept is to remap an image according to some mathematical transformation such that the image is warped around a maculopathic defect (scotoma) or within the rp foveal region of retinal sensitivity. NASA/JSC has been pursuing this research using angle invariant transformations with testing of the resulting remapping using subjects and facilities of the University of Houston, College of Optometry. Testing is facilitated by use of a hardware device, the Programmable Remapper, to provide the remapping of video images. This report presents the results of studies of alternative remapping transformations with the objective of improving subject reading rates and pattern recognition. In particular a form of conformal transformation was developed which provides for a smooth warping of an image around a scotoma. In such a case it is shown that distortion of characters and lines of characters is minimized which should lead to enhanced character recognition. In addition studies were made of alternative transformations which, although not conformal, provide for similar low character distortion remapping. A second, non-conformal transformation was studied for remapping of images to aid rp impairments. In this case a transformation was investigated which allows remapping of a vision field into a circular area representing the foveal retina region. The size and spatial representation of the image are selectable. It is shown that parametric adjustments allow for a wide variation of how a visual field is presented to the sensitive retina. This study also presents some preliminary considerations of how a prosthetic device could be implemented in a practical sense, vis-a-vis, size, weight and portability.

  14. Clinical use of multifocal visual-evoked potentials in a glaucoma practice: a prospective study

    PubMed Central

    Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.

    2012-01-01

    Purpose To test a framework that describes how the multifocal visual-evoked potential (mfVEP) technique is used in a particular glaucoma practice. Methods In this prospective, descriptive study, glaucoma suspects, ocular hypertensives and glaucoma patients were referred for mfVEP testing by a single glaucoma specialist over a 2-year period. All patients underwent standard automated perimetry (SAP) and mfVEP testing within 3 months. Two hundred and ten patients (420 eyes) were referred for mfVEP testing for the following reasons: (1) normal SAP tests suspected of early functional loss (ocular hypertensives, n = 43; and glaucoma suspects on the basis of suspicious optic disks, n = 52); (2) normal-tension glaucoma patients with suspected central SAP defects (n = 33); and (3) SAP abnormalities needing confirmation (n = 82). Results All the glaucoma suspects with normal SAP and mfVEP results remained untreated. Of those with abnormal mfVEP results, 68 % (15/22) were treated because the abnormal regions on the mfVEP were consistent with the abnormal regions seen during clinical examination of the optic disk. The mfVEP was abnormal in 86 % (69/80) of eyes with glaucomatous optic neuropathy and SAP damage, even though it did not result in an altered treatment regimen. In NTG patients, the mfVEP showed central defects in 44 % (12 of 27) of the eyes with apparently normal central fields and confirmed central scotomata in 92 % (36 of 39), leading to more rigorous surveillance of these patients. Conclusions In a clinical practice, the mfVEP was used when clinical examination and subjective visual fields provided insufficient or conflicting information. This information influenced clinical management. PMID:22476612

  15. Clinical use of multifocal visual-evoked potentials in a glaucoma practice: a prospective study.

    PubMed

    De Moraes, Carlos Gustavo; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2012-08-01

    To test a framework that describes how the multifocal visual-evoked potential (mfVEP) technique is used in a particular glaucoma practice. In this prospective, descriptive study, glaucoma suspects, ocular hypertensives and glaucoma patients were referred for mfVEP testing by a single glaucoma specialist over a 2-year period. All patients underwent standard automated perimetry (SAP) and mfVEP testing within 3 months. Two hundred and ten patients (420 eyes) were referred for mfVEP testing for the following reasons: (1) normal SAP tests suspected of early functional loss (ocular hypertensives, n = 43; and glaucoma suspects on the basis of suspicious optic disks, n = 52); (2) normal-tension glaucoma patients with suspected central SAP defects (n = 33); and (3) SAP abnormalities needing confirmation (n = 82). All the glaucoma suspects with normal SAP and mfVEP results remained untreated. Of those with abnormal mfVEP results, 68 % (15/22) were treated because the abnormal regions on the mfVEP were consistent with the abnormal regions seen during clinical examination of the optic disk. The mfVEP was abnormal in 86 % (69/80) of eyes with glaucomatous optic neuropathy and SAP damage, even though it did not result in an altered treatment regimen. In NTG patients, the mfVEP showed central defects in 44 % (12 of 27) of the eyes with apparently normal central fields and confirmed central scotomata in 92 % (36 of 39), leading to more rigorous surveillance of these patients. In a clinical practice, the mfVEP was used when clinical examination and subjective visual fields provided insufficient or conflicting information. This information influenced clinical management.

  16. Is the Cortical Deficit in Amblyopia Due to Reduced Cortical Magnification, Loss of Neural Resolution, or Neural Disorganization?

    PubMed

    Clavagnier, Simon; Dumoulin, Serge O; Hess, Robert F

    2015-11-04

    The neural basis of amblyopia is a matter of debate. The following possibilities have been suggested: loss of foveal cells, reduced cortical magnification, loss of spatial resolution of foveal cells, and topographical disarray in the cellular map. To resolve this we undertook a population receptive field (pRF) functional magnetic resonance imaging analysis in the central field in humans with moderate-to-severe amblyopia. We measured the relationship between averaged pRF size and retinal eccentricity in retinotopic visual areas. Results showed that cortical magnification is normal in the foveal field of strabismic amblyopes. However, the pRF sizes are enlarged for the amblyopic eye. We speculate that the pRF enlargement reflects loss of cellular resolution or an increased cellular positional disarray within the representation of the amblyopic eye. The neural basis of amblyopia, a visual deficit affecting 3% of the human population, remains a matter of debate. We undertook the first population receptive field functional magnetic resonance imaging analysis in participants with amblyopia and compared the projections from the amblyopic and fellow normal eye in the visual cortex. The projection from the amblyopic eye was found to have a normal cortical magnification factor, enlarged population receptive field sizes, and topographic disorganization in all early visual areas. This is consistent with an explanation of amblyopia as an immature system with a normal complement of cells whose spatial resolution is reduced and whose topographical map is disordered. This bears upon a number of competing theories for the psychophysical defect and affects future treatment therapies. Copyright © 2015 the authors 0270-6474/15/3514740-16$15.00/0.

  17. Sector retinitis pigmentosa.

    PubMed

    Van Woerkom, Craig; Ferrucci, Steven

    2005-05-01

    Retinitis pigmentosa (RP) is one of the most common hereditary retinal dystrophies and causes of visual impairment affecting all age groups. The reported incidence varies, but is considered to be between 1 in 3,000 to 1 in 7,000. Sector retinitis pigmentosa is an atypical form of RP that is characterized by regionalized areas of bone spicule pigmentation, usually in the inferior quadrants of the retina. A 57-year-old Hispanic man with a history of previously diagnosed retinitis pigmentosa came to the clinic with a longstanding symptom of decreased vision at night. Bone spicule pigmentation was found in the nasal and inferior quadrants in each eye. He demonstrated superior and temporal visual-field loss corresponding to the areas of the affected retina. Clinical measurements of visual-field loss, best-corrected visual acuity, and ophthalmoscopic appearance have remained stable during the five years the patient has been followed. Sector retinitis pigmentosa is an atypical form of RP that is characterized by bilateral pigmentary retinopathy, usually isolated to the inferior quadrants. The remainder of the retina appears clinically normal, although studies have found functional abnormalities in these areas as well. Sector RP is generally considered a stationary to slowly progressive disease, with subnormal electro-retinogram findings and visual-field defects corresponding to the involved retinal sectors. Management of RP is very difficult because there are no proven methods of treatment. Studies have shown 15,000 IU of vitamin A palmitate per day may slow the progression, though this result is controversial. Low vision rehabilitation, long wavelength pass filters, and pedigree counseling remain the mainstay of management.

  18. Optical coherence tomography detects characteristic retinal nerve fiber layer thickness corresponding to band atrophy of the optic discs.

    PubMed

    Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira

    2004-12-01

    To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.

  19. Dichoptic stimulation improves detection of glaucoma with multifocal visual evoked potentials.

    PubMed

    Arvind, Hemamalini; Klistorner, Alexander; Graham, Stuart; Grigg, John; Goldberg, Ivan; Klistorner, Asya; Billson, Frank A

    2007-10-01

    To determine whether simultaneous binocular (dichoptic) stimulation for multifocal visual evoked potentials (mfVEP) detects glaucomatous defects and decreases intereye variability. Twenty-eight patients with glaucoma and 30 healthy subjects underwent mfVEP on monocular and dichoptic stimulation. Dichoptic stimulation was presented with the use of virtual reality goggles (recording time, 7 minutes). Monocular mfVEPs were recorded sequentially for each eye (recording time, 10 minutes). Comparison of mean relative asymmetry coefficient (RAC; calculated as difference in amplitudes between eyes/sum of amplitudes of both eyes at each segment) on monocular and dichoptic mfVEP revealed significantly lower RAC on dichoptic (0.003 +/- 0.03) compared with monocular testing (-0.02 +/- 0.04; P = 0.002). In all 28 patients, dichoptic mfVEP identified defects with excellent topographic correspondence. Of 56 hemifields (28 eyes), 33 had Humphrey visual field (HFA) scotomas, all of which were detected by dichoptic mfVEP. Among 23 hemifields with normal HFA, two were abnormal on monocular and dichoptic mfVEP. Five hemifields (five patients) normal on HFA and monocular mfVEP were abnormal on dichoptic mfVEP. In all five patients, corresponding rim changes were observed on disc photographs. Mean RAC of glaucomatous eyes was significantly higher on dichoptic (0.283 +/- 0.18) compared with monocular (0.199 +/- 0.12) tests (P = 0.0006). Dichoptic mfVEP not only detects HFA losses, it may identify early defects in areas unaffected on HFA and monocular mfVEP while reducing testing time by 30%. Asymmetry was tighter among healthy subjects but wider in patients with glaucoma on simultaneous binocular stimulation, which is potentially a new tool in the early detection of glaucoma.

  20. Usage of Accessibility Options for the iPhone and iPad in a Visually Impaired Population.

    PubMed

    Robinson, Joshua L; Braimah Avery, Vanessa; Chun, Rob; Pusateri, Gregg; Jay, Walter M

    2017-01-01

    The iPad and iPhone have a number of low-vision accessibility features including Siri Voice Assistant, Large Text, Zoom Magnification, Invert Colors, Voice Over, and Speech Selection. We studied their usage within a low-vision population. Patients were recruited to participate in an IRB-approved survey regarding their usage of the iPad and/or iPhone. Participants met one of the following criteria: best corrected visual acuity (BCVA) of 20/60 or worse, or significant peripheral visual field defects. Thirty-three low-vision patients agreed to participate (mean age 54.3 years). There were 18 different diagnoses represented and the average visual acuity of respondents was 20/119 in the right eye and 20/133 in the left eye. The most commonly used vision accessibility features were Zoom Magnification and Large Text. Although many patients are using the low-vision accessibility features, few are receiving training or recommendations from their eye care specialist.

  1. Scanning laser polarimetry using variable corneal compensation in the detection of glaucoma with localized visual field defects.

    PubMed

    Kook, Michael S; Cho, Hyun-soo; Seong, Mincheol; Choi, Jaewan

    2005-11-01

    To evaluate the ability of scanning laser polarimetry parameters and a novel deviation map algorithm to discriminate between healthy and early glaucomatous eyes with localized visual field (VF) defects confined to one hemifield. Prospective case-control study. Seventy glaucomatous eyes with localized VF defects and 66 normal controls. A Humphrey field analyzer 24-2 full-threshold test and scanning laser polarimetry with variable corneal compensation were used. We assessed the sensitivity and specificity of scanning laser polarimetry parameters, sensitivity and cutoff values for scanning laser polarimetry deviation map algorithms at different specificity values (80%, 90%, and 95%) in the detection of glaucoma, and correlations between the algorithms of scanning laser polarimetry and of the pattern deviation derived from Humphrey field analyzer testing. There were significant differences between the glaucoma group and normal subjects in the mean parametric values of the temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and TSNIT standard deviation (SD) (P<0.05). The sensitivity and specificity of each scanning laser polarimetry variable was as follows: TSNIT, 44.3% (95% confidence interval [CI], 39.8%-49.8%) and 100% (95.4%-100%); superior average, 30% (25.5%-34.5%) and 97% (93.5%-100%); inferior average, 45.7% (42.2%-49.2%) and 100% (95.8%-100%); and TSNIT SD, 30% (25.9%-34.1%) and 97% (93.2%-100%), respectively (when abnormal was defined as P<0.05). Based on nerve fiber indicator cutoff values of > or =30 and > or =51 to indicate glaucoma, sensitivities were 54.3% (50.1%-58.5%) and 10% (6.4%-13.6%), and specificities were 97% (93.2%-100%) and 100% (95.8%-100%), respectively. The range of areas under the receiver operating characteristic curves using the scanning laser polarimetry deviation map algorithm was 0.790 to 0.879. Overall sensitivities combining each probability scale and severity score at 80%, 90%, and 95% specificities were 90.0% (95% CI, 86.4%-93.6%), 71.4% (67.4%-75.4%), and 60.0% (56.2%-63.8%), respectively. There was a statistically significant correlation between the scanning laser polarimetry severity score and the VF severity score (R2 = 0.360, P<0.001). Scanning laser polarimetry parameters may not be sufficiently sensitive to detect glaucomatous patients with localized VF damage. Our algorithm using the scanning laser polarimetry deviation map may enhance the understanding of scanning laser polarimetry printouts in terms of the locality, deviation size, and severity of localized retinal nerve fiber layer defects in eyes with localized VF loss.

  2. Multifocal Visual Evoked Potential in Eyes With Temporal Hemianopia From Chiasmal Compression: Correlation With Standard Automated Perimetry and OCT Findings.

    PubMed

    Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R

    2017-09-01

    To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.

  3. Plant photonics: application of optical coherence tomography to monitor defects and rots in onion

    NASA Astrophysics Data System (ADS)

    Meglinski, I. V.; Buranachai, C.; Terry, L. A.

    2010-04-01

    The incidence of physiological and/or pathological defects in many fresh produce types is still unacceptably high and accounts for a large proportion of waste. With increasing interest in food security their remains strong demand in developing reliable and cost effective technologies for non-destructive screening of internal defects and rots, these being deemed unacceptable by consumers. It is well recognized that the internal defects and structure of turbid scattering media can be effectively visualized by using optical coherence tomography (OCT). In the present study, the high spatial resolution and advantages of OCT have been demonstrated for imaging the skins and outer laminae (concentric tissue layers) of intact whole onion bulbs with a view to non-invasively visualizing potential incidence/severity of internal defects.

  4. Initial Arcuate Defects within the Central 10 Degrees in Glaucoma

    PubMed Central

    Raza, Ali S.; de Moraes, Carlos Gustavo V.; Odel, Jeffrey G.; Greenstein, Vivienne C.; Liebmann, Jeffrey M.; Ritch, Robert

    2011-01-01

    Purpose. To better understand the relationship between the spatial patterns of functional (visual field [VF] loss) and structural (axon loss) abnormalities in patients with glaucomatous arcuate defects largely confined to the central 10° on achromatic perimetry. Methods. Eleven eyes (9 patients) with arcuate glaucomatous VF defects largely confined to the macula were selected from a larger group of patients with both 10-2 and 24-2 VF tests. Eyes were included if their 10-2 VF had an arcuate defect and if the 24-2 test was normal outside the central 10° (i.e., did not have a cluster of three contiguous points within a hemifield). For the structural analysis, plots of retinal nerve fiber layer (RNFL) thickness of the macula were obtained with frequency-domain optical coherence tomography (fdOCT). The optic disc locations of the RNFL defects were identified on peripapillary fdOCT scans. Results. The VF arcuate defects extended to within 1° of fixation on the 10-2 test and were present in the superior hemifield in 10 of the 11 eyes. The arcuate RNFL damage, seen in the macular fdOCT scans of all 11 eyes, involved the temporal and inferior temporal portions of the disc on the peripapillary scans. Conclusions. Glaucomatous arcuate defects of the macula's RNFL meet the disc temporal to the peak of the main arcuate bundles and produce a range of macular VF defects from clear arcuate scotomas to a papillofoveal horizontal step (“pistol barrel scotoma”). If RGC displacement is taken into consideration, the RNFL and VF defects can be compared directly. PMID:20881293

  5. Retinal abnormalities in β-thalassemia major.

    PubMed

    Bhoiwala, Devang L; Dunaief, Joshua L

    2016-01-01

    Patients with beta (β)-thalassemia (β-TM: β-thalassemia major, β-TI: β-thalassemia intermedia) have a variety of complications that may affect all organs, including the eye. Ocular abnormalities include retinal pigment epithelial degeneration, angioid streaks, venous tortuosity, night blindness, visual field defects, decreased visual acuity, color vision abnormalities, and acute visual loss. Patients with β-thalassemia major are transfusion dependent and require iron chelation therapy to survive. Retinal degeneration may result from either retinal iron accumulation from transfusion-induced iron overload or retinal toxicity induced by iron chelation therapy. Some who were never treated with iron chelation therapy exhibited retinopathy, and others receiving iron chelation therapy had chelator-induced retinopathy. We will focus on retinal abnormalities present in individuals with β-thalassemia major viewed in light of new findings on the mechanisms and manifestations of retinal iron toxicity. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Anterior ischemic optic neuropathy in a patient with Churg-Strauss syndrome.

    PubMed

    Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won; Lee, Sang Joon

    2012-12-01

    We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications.

  7. Anterior Ischemic Optic Neuropathy in a Patient with Churg-Strauss Syndrome

    PubMed Central

    Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won

    2012-01-01

    We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications. PMID:23204805

  8. Orbital complications:diagnosis of different rhinological causes.

    PubMed

    Matsuba, Yumiko; Strassen, Ulrich; Hofauer, Benedikt; Bas, Murat; Knopf, Andreas

    2015-09-01

    To evaluate the clinical course of orbital complication using a standardised diagnostic pathway. Seventy-three patients with orbital complications underwent a multimodal diagnostic pathway comprising ENT examination, leucocytes/CRP, CT-/MRI-scanning and disease-related data. Twenty-nine patients suffered from rhinosinusitis, 28 from mucoceles, 13 patients from neoplasms and three patients from rheumatic disorders. Clinical examination diagnosed 60 patients with eyelid swelling, 55 patients with ocular pain, 14 patients with diplopia, 4 patients with exophthalmus, 29 patients with visual field defect and 4 patients with visual loss. The diagnostic pathway identified acute rhinosinusitis with a sensitivity/specificity of 90 %/90 %, mucoceles with 79 %/100 %, neoplasms with 100 %/96 % and granulomatosis with polyangiitis with 100 %/100 %, respectively. All patients left the hospital in good general condition and with regular ocular motility; two patients suffered persistent visual loss. The standardised application of a widely accepted diagnostic pathway reliably distinguishes different causes of orbital complication.

  9. Design of a reading test for low-vision image warping

    NASA Astrophysics Data System (ADS)

    Loshin, David S.; Wensveen, Janice; Juday, Richard D.; Barton, R. Shane

    1993-08-01

    NASA and the University of Houston College of Optometry are examining the efficacy of image warping as a possible prosthesis for at least two forms of low vision -- maculopathy and retinitis pigmentosa. Before incurring the expense of reducing the concept to practice, one would wish to have confidence that a worthwhile improvement in visual function would result. NASA's Programmable Remapper (PR) can warp an input image onto arbitrary geometric coordinate systems at full video rate, and it has recently been upgraded to accept computer- generated video text. We have integrated the Remapper with an SRI eye tracker to simulate visual malfunction in normal observers. A reading performance test has been developed to determine if the proposed warpings yield an increase in visual function; i.e., reading speed. We describe the preliminary experimental results of this reading test with a simulated central field defect with and without remapped images.

  10. Design of a reading test for low vision image warping

    NASA Technical Reports Server (NTRS)

    Loshin, David S.; Wensveen, Janice; Juday, Richard D.; Barton, R. S.

    1993-01-01

    NASA and the University of Houston College of Optometry are examining the efficacy of image warping as a possible prosthesis for at least two forms of low vision - maculopathy and retinitis pigmentosa. Before incurring the expense of reducing the concept to practice, one would wish to have confidence that a worthwhile improvement in visual function would result. NASA's Programmable Remapper (PR) can warp an input image onto arbitrary geometric coordinate systems at full video rate, and it has recently been upgraded to accept computer-generated video text. We have integrated the Remapper with an SRI eye tracker to simulate visual malfunction in normal observers. A reading performance test has been developed to determine if the proposed warpings yield an increase in visual function; i.e., reading speed. We will describe the preliminary experimental results of this reading test with a simulated central field defect with and without remapped images.

  11. SPECT in patients with cortical visual loss.

    PubMed

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  12. Preliminary study on combined pharmacological and laser treatment in optic pit serous maculopathy after literature review.

    PubMed

    Nebbioso, M; Dapoto, L; Lenarduzzi, F; Belcaro, G; Malagola, R

    2012-12-01

    The pit of the optic nerve head (ON) is a rare congenital defect that sometimes presents itself with a maculopathy of various neuroretinal layers for unknown reason. This study was focused, before and after pharmacological and parasurgical treatment, on the structural and functional visual assessment in a patient with optic pit maculopathy (OPM). In order to achieve this the latest generation of hi-tech diagnostic tests were used, such as Spectral-Domain Optical Coherence Tomography (SD-OCT), Visual Evoked Potentials (VEP), full-field Electroretinography (ERG), multifocal ERG (mfERG), Microperimetry (MP-1), Standard Automated Perimetry (SAP), Fluorescein Angiography (FA) and Indocyanine Green Angiography (ICG). The research was conducted through a review of past and recent literature.

  13. Functional Defects in Color Vision in Patients With Choroideremia.

    PubMed

    Jolly, Jasleen K; Groppe, Markus; Birks, Jacqueline; Downes, Susan M; MacLaren, Robert E

    2015-10-01

    To characterize defects in color vision in patients with choroideremia. Prospective cohort study. Thirty patients with choroideremia (41 eyes) and 10 age-matched male controls (19 eyes) with visual acuity of ≥6/36 attending outpatient clinics in Oxford Eye Hospital underwent color vision testing with the Farnsworth-Munsell 100 hue test, visual acuity testing, and autofluorescence imaging. To exclude changes caused by degeneration of the fovea, a subgroup of 14 patients with a visual acuity ≥6/6 was analyzed. Calculated color vision total error scores were compared between the groups and related to a range of factors using a random-effects model. Mean color vision total error scores were 120 (95% confidence interval [CI] 92, 156) in the ≥6/6 choroideremia group, 206 (95% CI 161, 266) in the <6/6 visual acuity choroideremia group, and 47 (95% CI 32, 69) in the control group. Covariate analysis showed a significant difference in color vision total error score between the groups (P < .001 between each group). Patients with choroideremia have a functional defect in color vision compared with age-matched controls. The color vision defect deteriorates as the degeneration encroaches on the fovea. The presence of an early functional defect in color vision provides a useful biomarker against which to assess successful gene transfer in gene therapy trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Decay detection in red oak trees using a combination of visual inspection, acoustic testing, and resistance microdrilling

    Treesearch

    Xiping Wang; R. Bruce Allison

    2008-01-01

    Arborists are often challenged to identify internal structural defects hidden from view within tree trunks. This article reports the results of a study using a trunk inspection protocol combining visual observation, single-path stress wave testing, acoustic tomography, and resistance microdrilling to detect internal defects. Two century-old red oak (Quercus rubra)...

  15. Transmembrane voltage potential controls embryonic eye patterning in Xenopus laevis

    PubMed Central

    Pai, Vaibhav P.; Aw, Sherry; Shomrat, Tal; Lemire, Joan M.; Levin, Michael

    2012-01-01

    Uncovering the molecular mechanisms of eye development is crucial for understanding the embryonic morphogenesis of complex structures, as well as for the establishment of novel biomedical approaches to address birth defects and injuries of the visual system. Here, we characterize change in transmembrane voltage potential (Vmem) as a novel biophysical signal for eye induction in Xenopus laevis. During normal embryogenesis, a striking hyperpolarization demarcates a specific cluster of cells in the anterior neural field. Depolarizing the dorsal lineages in which these cells reside results in malformed eyes. Manipulating Vmem of non-eye cells induces well-formed ectopic eyes that are morphologically and histologically similar to endogenous eyes. Remarkably, such ectopic eyes can be induced far outside the anterior neural field. A Ca2+ channel-dependent pathway transduces the Vmem signal and regulates patterning of eye field transcription factors. These data reveal a new, instructive role for membrane voltage during embryogenesis and demonstrate that Vmem is a crucial upstream signal in eye development. Learning to control bioelectric initiators of organogenesis offers significant insight into birth defects that affect the eye and might have significant implications for regenerative approaches to ocular diseases. PMID:22159581

  16. Evaluation of multifocal visual evoked potentials in patients with Graves' orbitopathy and subclinical optic nerve involvement.

    PubMed

    Pérez-Rico, Consuelo; Rodríguez-González, Natividad; Arévalo-Serrano, Juan; Blanco, Román

    2012-08-01

    Dysthyroid optic neuropathy is the most serious, although infrequent (8-10 %) complication in Graves' orbitopathy (GO). It is known that early stages of compressive optic neuropathy may produce reversible visual field defects, suggesting axoplasmic stasis rather than ganglion cell death. This observational, cross-sectional, case-control study assessed 34 consecutive patients (65 eyes) with Graves' hyperthyroidism and longstanding GO and 31 age-matched control subjects. The patients' multifocal visual evoked potentials (mfVEP) were compared to their clinical and psychophysical (standard automated perimetry [SAP]) and structural (optic coherence tomography [OCT]) diagnostic test data. Abnormal cluster defects were found in 12.3 % and 3.1 % of eyes on the interocular and monocular amplitude analysis mfVEP probability plots, respectively. As well, mfVEP latencies delays were found in 13.8 and 20 % of eyes on the interocular and monocular analysis probability plots, respectively. Interestingly, 19 % of patients with GO had ocular hypertension, and a strong correlation between intraocular pressure measured at upgaze and mfVEP latency was found. MfVEP amplitudes and visual acuity were significantly related to each other (P < 0.05), but not with the latencies delays. However, relationships between the interocular or monocular mfVEP amplitudes and latencies analysis and SAP indices or OCT data were not statistically significant. One-third of our patients with GO showed changes in the mfVEP, indicating significant subclinical optic nerve dysfunction. In this sense, the mfVEP may be a useful diagnostic tool in the clinic for early diagnosis and monitoring of optic nerve function abnormalities in patients with GO.

  17. Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array

    PubMed Central

    Delrue, Steven; Aleshin, Vladislav; Sørensen, Mikael; De Lathauwer, Lieven

    2017-01-01

    The importance of Non-Destructive Testing (NDT) to check the integrity of materials in different fields of industry has increased significantly in recent years. Actually, industry demands NDT methods that allow fast (preferably non-contact) detection and localization of early-stage defects with easy-to-interpret results, so that even a non-expert field worker can carry out the testing. The main challenge is to combine as many of these requirements into one single technique. The concept of acoustic cameras, developed for low frequency NDT, meets most of the above-mentioned requirements. These cameras make use of an array of microphones to visualize noise sources by estimating the Direction Of Arrival (DOA) of the impinging sound waves. Until now, however, because of limitations in the frequency range and the lack of integrated nonlinear post-processing, acoustic camera systems have never been used for the localization of incipient damage. The goal of the current paper is to numerically investigate the capabilities of locating incipient damage by measuring the nonlinear airborne emission of the defect using a non-contact ultrasonic sensor array. We will consider a simple case of a sample with a single near-surface crack and prove that after efficient excitation of the defect sample, the nonlinear defect responses can be detected by a uniform linear sensor array. These responses are then used to determine the location of the defect by means of three different DOA algorithms. The results obtained in this study can be considered as a first step towards the development of a nonlinear ultrasonic camera system, comprising the ultrasonic sensor array as the hardware and nonlinear post-processing and source localization software. PMID:28441738

  18. Weld quality inspection using laser-EMAT ultrasonic system and C-scan method

    NASA Astrophysics Data System (ADS)

    Yang, Lei; Ume, I. Charles

    2014-02-01

    Laser/EMAT ultrasonic technique has attracted more and more interests in weld quality inspection because of its non-destructive and non-contact characteristics. When ultrasonic techniques are used to detect welds joining relative thin plates, the dominant ultrasonic waves present in the plates are Lamb waves, which propagate all through the thickness. Traditional Time of Flight(ToF) method loses its power. The broadband nature of laser excited ultrasound plus dispersive and multi-modal characteristic of Lamb waves make the EMAT acquired signals very complicated in this situation. Challenge rises in interpreting the received signals and establishing relationship between signal feature and weld quality. In this paper, the laser/EMAT ultrasonic technique was applied in a C-scan manner to record full wave propagation field over an area close to the weld. Then the effect of weld defect on the propagation field of Lamb waves was studied visually by watching an movie resulted from the recorded signals. This method was proved to be effective to detect the presence of hidden defect in the weld. Discrete wavelet transform(DWT) was applied to characterize the acquired ultrasonic signals and ideal band-pass filter was used to isolate wave components most sensitive to the weld defect. Different interactions with the weld defect were observed for different wave components. Thus this C-Scan method, combined with DWT and ideal band-pass filter, proved to be an effective methodology to experimentally study interactions of various laser excited Lamb Wave components with weld defect. In this work, the method was demonstrated by inspecting a hidden local incomplete penetration in weld. In fact, this method can be applied to study Lamb Wave interactions with any type of structural inconsistency. This work also proposed a ideal filtered based method to effectively reduce the total experimental time.

  19. Comparison of localized retinal nerve fiber layer defects between a low-teen intraocular pressure group and a high-teen intraocular pressure group in normal-tension glaucoma patients.

    PubMed

    Kim, Dong Myung; Seo, Je Hyun; Kim, Seok Hwan; Hwang, Seung-Sik

    2007-05-01

    To compare the features of localized retinal nerve fiber layer (RNFL) defects between a low-teen intraocular pressure (IOP) group and a high-teen IOP group in normal-tension glaucoma (NTG) patients. Seventy-seven eyes of 77 NTG patients showing localized RNFL defects on RNFL photographs and corresponding visual filed defects at the initial visit to a glaucoma specialist were selected for this study. Patients with range of diurnal IOP within low-teen or high-teen in both eyes were included. All participants completed refraction, diurnal IOP measurement, central corneal thickness (CCT) measurement, stereoscopic disc photography, RNFL photography, and automated perimetry. On RNFL photograph, approximation of the defect to the macula (angle alpha) and width of the defects (angle beta) were measured to represent RNFL defects. The patients were divided into 2 groups according to the level of IOP. A low-teen group had highest IOP of 15 mm Hg (group B). Age at diagnosis, percentage of male patients, systemic disease, refraction, CCT, highest IOP, angle alpha, angle beta, and mean deviation and pattern standard deviation of visual field were compared between the 2 groups. Age at diagnosis of NTG, age distribution, percentage of male patients, systemic disease, spherical equivalent of refraction, CCT, mean deviation, and pattern standard deviation were not different between the 2 groups. Highest IOP was 13.8+/-1.2 mm Hg in group A and 19.2+/-1.4 mm Hg in group B (P<0.001). Angle alpha was significantly smaller in group A than in group B (37.0+/-14.0 vs. 56.5+/-21.2 degrees, P<0.001), whereas angle beta was not different between the 2 groups (39.9+/-17.9 vs. 37.5+/-15.9 degrees, P=0.54). There were no significant correlations between spherical equivalent and angle alpha (r=-0.03, P=0.82), between spherical equivalent and angle beta (r=-0.04, P=0.74), and between angle alpha and angle beta (r=-0.21, P=0.07). Localized RNFL defect was closer to the center of the macula in group A than in group B, whereas width of defects was not different between the 2 groups. These findings provide indirect evidence to suggest that more than one pathogenic mechanism may exist in the development of RNFL defects in NTG.

  20. Therapeutic effect of the compound Danshen dripping pill combined with laser acupoint irradiation on early diabetic retinopathy

    NASA Astrophysics Data System (ADS)

    Liu, Hui-Hui; Xiong, Guo-Xin; Zhang, Li-Ping

    2017-06-01

    To investigate the therapeutic effect of the compound Danshen dripping pill combined with laser acupoint irradiation on early diabetic retinopathy, 19 patients with early diabetic retinopathy were randomly divided into a treatment group and a control group. The TaiYang, YangBai, YuYao and ZanZhu acupoints of patients in the treatment group were irradiated with a semiconductor laser combined with the oral compound Danshen dropping pills, while those in the control group only used the oral compound Danshen dropping pills. The indicators of vision, mean defect of light sensitivity in the visual field, renal function and fasting blood glucose, were examined to evaluate the efficacy. After treatment, the above indicators of patients in the two groups were significantly improved and there was a significant difference between the two groups. This showed that the compound Danshen dripping pills combined with the laser acupoint irradiation can improve the ischemic and anoxic state of early diabetic retinopathy and improve the visual field.

  1. Sensitivity and specificity of scanning laser polarimetry using the GDx.

    PubMed

    Munkwitz, S; Funk, J; Loeffler, K U; Harbarth, U; Kremmer, S

    2004-09-01

    To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD). Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterioration of the disc over time clearly visible upon flicker comparison, and group C included 16 eyes with glaucomatous or non-glaucomatous NFBD clearly visible on red free photographs. Forty four eyes of 22 healthy volunteers served as controls. The GDx printouts of all subjects were evaluated by three independent observers in a masked fashion and without the clinical picture of the optic disc. Two of the three observers (SK, UH) were GDx experts, one (KUL) was an untrained GDx user. Among the GDx experts, sensitivity/specificity was 100%/100% (SK) and 90%/100% (UH) in detecting advanced glaucoma, and 100%/100% (SK) and 90%/100% (UH) in detecting early glaucoma. The sensitivity in detecting NFBD was only 37.5% (SK and UH). For the untrained GDx user the corresponding values were 50%/100% (group A), 20%/100% (group B), and 12.5%/91% (group C). Detection of (early) glaucoma damage by the GDx, evaluated by trained experts, can be extremely high. To optimise its benefit in clinical routine training in interpreting GDx printouts is highly recommended. Detection of localised NFBD is crucial, even for experts.

  2. The first prototype of chromatic pupillometer for objective perimetry in retinal degeneration patients

    NASA Astrophysics Data System (ADS)

    Rotenstreich, Ygal; Chibel, Ron; Haj Yahia, Soad; Achiron, Asaf; Mahajna, Mohamad; Belkin, Michael; Sher, Ifat

    2015-03-01

    We recently demonstrated the feasibility of quantifying pupil responses (PR) to multifocal chromatic light stimuli for objectively assessing visual field (VF). Here we assessed a second-generation chromatic multifocal pupillometer device with 76 LEDs of 18 degree visual field and a smaller spot size (2mm diameter), aimed of achieving better perimetric resolution. A computerized infrared pupillometer was used to record PR to short- and long-wavelength stimuli (peak 485 nm and 640 nm, respectively) presented by 76 LEDs, 1.8mm spot size, at light intensities of 10-1000 cd/m2 at different points of the 18 degree VF. PR amplitude was measured in 11 retinitis pigmentosa (RP) patients and 20 normal agedmatched controls. RP patients demonstrated statistically significant reduced pupil contraction amplitude in majority of perimetric locations under testing conditions that emphasized rod contribution (short-wavelength stimuli at 200 cd/m2) in peripheral locations (p<0.05). By contrast, the amplitude of pupillary responses under testing conditions that emphasized cone cell contribution (long-wavelength stimuli at 1000 cd/m2) were not significantly different between the groups in majority of perimetric locations, particularly in central locations. Minimal pupil contraction was recorded in areas that were non-detected by chromatic Goldmann. This study demonstrates the feasibility of using pupillometerbased chromatic perimetry for objectively assessing VF defects and retinal function in patients with retinal degeneration. This method may be used to distinguish between the damaged cells underlying the VF defect.

  3. Evaluation of retinal nerve fiber layer thickness in the area of apparently normal hemifield in glaucomatous eyes with optical coherence tomography.

    PubMed

    Kee, Changwon; Cho, Changhwan

    2003-06-01

    The authors investigated the correlation between visual field defects detected by automated perimetry and the thickness of the retinal nerve fiber layer measured with optical coherence tomography, and examined whether there is a decrease in retinal nerve fiber layer thickness in the apparently normal hemifield of glaucomatous eyes. Forty-one patients with glaucoma and 41 normal control subjects were included in this study. Statistical correlations between the sum of the total deviation of 37 stimuli of each hemifield and the ratio of decrease in retinal nerve fiber layer thickness were evaluated. The statistical difference between the retinal nerve fiber layer thickness of the apparently normal hemifield in glaucomatous eyes and that of the corresponding hemifield in normal subjects was also evaluated. There was a statistically significant correlation in the sum of the total deviation and retinal nerve fiber layer thickness decrease ratio (superior hemifield, P = 0.001; inferior hemifield, P = 0.003). There was no significant decrease in retinal nerve fiber layer thickness in the area that corresponded to the normal visual field in the hemifield defect with respect to the horizontal meridian in glaucomatous eyes (superior side, P = 0.148; inferior side, P = 0.341). Optical coherence tomography was capable of demonstrating and measuring retinal nerve fiber layer abnormalities. No changes in the retinal nerve fiber layer thickness of the apparently normal hemifield were observed in glaucomatous eyes.

  4. Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.

    PubMed

    Lima, Breno da Rocha; Perry, Julian D

    2013-01-01

    To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p < 0.0001). Increased muscle index was also related to optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.

  5. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Takeda, Ryuji; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between consecutive deterioration of mean deviation (MD) value and glaucomatous visual field (VF) progression in open-angle glaucoma (OAG), including primary OAG and normal tension glaucoma. The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program). The VF progression was defined by a significantly negative MD slope (MD slope worsening) at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed. A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%), while no significant progression was evident in 93 eyes of 93 patients (56.4%). There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran-Armitage trend test). A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224) and four (odds ratio: 3.6, P=0.0008) consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282). The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0.01). This retrospective study has shown that three or more consecutive deterioration of MD value might be a predictor to future significant MD slope worsening in OAG.

  6. Topological defects in open string field theory

    NASA Astrophysics Data System (ADS)

    Kojita, Toshiko; Maccaferri, Carlo; Masuda, Toru; Schnabl, Martin

    2018-04-01

    We show how conformal field theory topological defects can relate solutions of open string field theory for different boundary conditions. To this end we generalize the results of Graham and Watts to include the action of defects on boundary condition changing fields. Special care is devoted to the general case when nontrivial multiplicities arise upon defect action. Surprisingly the fusion algebra of defects is realized on open string fields only up to a (star algebra) isomorphism.

  7. Retinitis pigmentosa.

    PubMed

    Hamel, Christian

    2006-10-11

    Retinitis pigmentosa (RP) is an inherited retinal dystrophy caused by the loss of photoreceptors and characterized by retinal pigment deposits visible on fundus examination. Prevalence of non syndromic RP is approximately 1/4,000. The most common form of RP is a rod-cone dystrophy, in which the first symptom is night blindness, followed by the progressive loss in the peripheral visual field in daylight, and eventually leading to blindness after several decades. Some extreme cases may have a rapid evolution over two decades or a slow progression that never leads to blindness. In some cases, the clinical presentation is a cone-rod dystrophy, in which the decrease in visual acuity predominates over the visual field loss. RP is usually non syndromic but there are also many syndromic forms, the most frequent being Usher syndrome. To date, 45 causative genes/loci have been identified in non syndromic RP (for the autosomal dominant, autosomal recessive, X-linked, and digenic forms). Clinical diagnosis is based on the presence of night blindness and peripheral visual field defects, lesions in the fundus, hypovolted electroretinogram traces, and progressive worsening of these signs. Molecular diagnosis can be made for some genes, but is not usually performed due to the tremendous genetic heterogeneity of the disease. Genetic counseling is always advised. Currently, there is no therapy that stops the evolution of the disease or restores the vision, so the visual prognosis is poor. The therapeutic approach is restricted to slowing down the degenerative process by sunlight protection and vitaminotherapy, treating the complications (cataract and macular edema), and helping patients to cope with the social and psychological impact of blindness. However, new therapeutic strategies are emerging from intensive research (gene therapy, neuroprotection, retinal prosthesis).

  8. Retinitis pigmentosa

    PubMed Central

    Hamel, Christian

    2006-01-01

    Retinitis pigmentosa (RP) is an inherited retinal dystrophy caused by the loss of photoreceptors and characterized by retinal pigment deposits visible on fundus examination. Prevalence of non syndromic RP is approximately 1/4,000. The most common form of RP is a rod-cone dystrophy, in which the first symptom is night blindness, followed by the progressive loss in the peripheral visual field in daylight, and eventually leading to blindness after several decades. Some extreme cases may have a rapid evolution over two decades or a slow progression that never leads to blindness. In some cases, the clinical presentation is a cone-rod dystrophy, in which the decrease in visual acuity predominates over the visual field loss. RP is usually non syndromic but there are also many syndromic forms, the most frequent being Usher syndrome. To date, 45 causative genes/loci have been identified in non syndromic RP (for the autosomal dominant, autosomal recessive, X-linked, and digenic forms). Clinical diagnosis is based on the presence of night blindness and peripheral visual field defects, lesions in the fundus, hypovolted electroretinogram traces, and progressive worsening of these signs. Molecular diagnosis can be made for some genes, but is not usually performed due to the tremendous genetic heterogeneity of the disease. Genetic counseling is always advised. Currently, there is no therapy that stops the evolution of the disease or restores the vision, so the visual prognosis is poor. The therapeutic approach is restricted to slowing down the degenerative process by sunlight protection and vitaminotherapy, treating the complications (cataract and macular edema), and helping patients to cope with the social and psychological impact of blindness. However, new therapeutic strategies are emerging from intensive research (gene therapy, neuroprotection, retinal prosthesis). PMID:17032466

  9. Evaluation of Visual Field Progression in Glaucoma: Quasar Regression Program and Event Analysis.

    PubMed

    Díaz-Alemán, Valentín T; González-Hernández, Marta; Perera-Sanz, Daniel; Armas-Domínguez, Karintia

    2016-01-01

    To determine the sensitivity, specificity and agreement between the Quasar program, glaucoma progression analysis (GPA II) event analysis and expert opinion in the detection of glaucomatous progression. The Quasar program is based on linear regression analysis of both mean defect (MD) and pattern standard deviation (PSD). Each series of visual fields was evaluated by three methods; Quasar, GPA II and four experts. The sensitivity, specificity and agreement (kappa) for each method was calculated, using expert opinion as the reference standard. The study included 439 SITA Standard visual fields of 56 eyes of 42 patients, with a mean of 7.8 ± 0.8 visual fields per eye. When suspected cases of progression were considered stable, sensitivity and specificity of Quasar, GPA II and the experts were 86.6% and 70.7%, 26.6% and 95.1%, and 86.6% and 92.6% respectively. When suspected cases of progression were considered as progressing, sensitivity and specificity of Quasar, GPA II and the experts were 79.1% and 81.2%, 45.8% and 90.6%, and 85.4% and 90.6% respectively. The agreement between Quasar and GPA II when suspected cases were considered stable or progressing was 0.03 and 0.28 respectively. The degree of agreement between Quasar and the experts when suspected cases were considered stable or progressing was 0.472 and 0.507. The degree of agreement between GPA II and the experts when suspected cases were considered stable or progressing was 0.262 and 0.342. The combination of MD and PSD regression analysis in the Quasar program showed better agreement with the experts and higher sensitivity than GPA II.

  10. Local defect resonance for sensitive non-destructive testing

    NASA Astrophysics Data System (ADS)

    Adebahr, W.; Solodov, I.; Rahammer, M.; Gulnizkij, N.; Kreutzbruck, M.

    2016-02-01

    Ultrasonic wave-defect interaction is a background of ultrasound activated techniques for imaging and non-destructive testing (NDT) of materials and industrial components. The interaction, primarily, results in acoustic response of a defect which provides attenuation and scattering of ultrasound used as an indicator of defects in conventional ultrasonic NDT. The derivative ultrasonic-induced effects include e.g. nonlinear, thermal, acousto-optic, etc. responses also applied for NDT and defect imaging. These secondary effects are normally relatively inefficient so that the corresponding NDT techniques require an elevated acoustic power and stand out from conventional ultrasonic NDT counterparts for their specific instrumentation particularly adapted to high-power ultrasonic. In this paper, a consistent way to enhance ultrasonic, optical and thermal defect responses and thus to reduce an ultrasonic power required is suggested by using selective ultrasonic activation of defects based on the concept of local defect resonance (LDR). A strong increase in vibration amplitude at LDR enables to reliably detect and visualize the defect as soon as the driving ultrasonic frequency is matched to the LDR frequency. This also provides a high frequency selectivity of the LDR-based imaging, i.e. an opportunity of detecting a certain defect among a multitude of other defects in material. Some examples are shown how to use LDR in non-destructive testing techniques, like vibrometry, ultrasonic thermography and shearography in order to enhance the sensitivity of defect visualization.

  11. DC current distribution mapping system of the solar panels using a HTS-SQUID gradiometer

    NASA Astrophysics Data System (ADS)

    Miyazaki, Shingo; Kasuya, Syohei; Mawardi Saari, Mohd; Sakai, Kenji; Kiwa, Toshihiko; Tsukamoto, Akira; Adachi, Seiji; Tanabe, Keiichi; Tsukada, Keiji

    2014-05-01

    Solar panels are expected to play a major role as a source of sustainable energy. In order to evaluate solar panels, non-destructive tests, such as defect inspections and response property evaluations, are necessary. We developed a DC current distribution mapping system of the solar panels using a High Critical Temperature Superconductor Superconducting Quantum Interference Device (HTS-SQUID) gradiometer with ramp edge type Josephson junctions. Two independent components of the magnetic fields perpendicular to the panel surface (∂Bz/∂x, ∂Bz/∂y) were detected. The direct current of the solar panel is visualized by calculating the composition of the two signal components, the phase angle, and mapping the DC current vector. The developed system can evaluate the uniformity of DC current distributions precisely and may be applicable for defect detection of solar panels.

  12. Photoreceptor change and visual outcome after idiopathic epiretinal membrane removal with or without additional internal limiting membrane peeling.

    PubMed

    Ahn, Seong Joon; Ahn, Jeeyun; Woo, Se Joon; Park, Kyu Hyung

    2014-01-01

    To compare the postoperative photoreceptor status and visual outcome after epiretinal membrane removal with or without additional internal limiting membrane (ILM) peeling. Medical records of 40 eyes from 37 patients undergoing epiretinal membrane removal with residual ILM peeling (additional ILM peeling group) and 69 eyes from 65 patients undergoing epiretinal membrane removal without additional ILM peeling (no additional peeling group) were reviewed. The length of defects in cone outer segment tips, inner segment/outer segment junction, and external limiting membrane line were measured using spectral domain optical coherence tomography images of the fovea before and at 1, 3, 6, and 12 months after the surgery. Cone outer segment tips and inner segment/outer segment junction line defects were most severe at postoperative 1 month and gradually restored at 12 months postoperatively. The cone outer segment tips line defect in the additional ILM peeling group was significantly greater than that in the no additional peeling group at postoperative 1 month (P = 0.006), and best-corrected visual acuity was significantly worse in the former group at the same month (P = 0.001). There was no significant difference in the defect size and best-corrected visual acuity at subsequent visits and recurrence rates between the two groups. Patients who received epiretinal membrane surgery without additional ILM peeling showed better visual and anatomical outcome than those with additional ILM peeling at postoperative 1 month. However, surgical outcomes were comparable between the two groups, thereafter. In terms of visual outcome and photoreceptor integrity, additional ILM peeling may not be an essential procedure.

  13. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  14. Metamorphopsia Score and Central Visual Field Outcomes in Diabetic Cystoid Macular Edema

    PubMed Central

    Brzozowska, Agnieszka; Maciejewski, Ryszard

    2018-01-01

    Aim To detect abnormality of the visual function in naïve patients with cystoid diabetic macular edema (DME) using M-charts, Amsler test, and white on white (W/W) and blue on yellow (B/Y) perimetry. Methods There were 64 eyes included in the study: 30 eyes with DME, 22 eyes with diabetes without DME, and 12 eyes of normal subjects. Conventional W/W perimetry and B/Y perimetry were performed within the central 10° of the visual field. To assess metamorphopsia, Amsler test and M-charts were used. Results The rate of detection of metamorphopsia was 37% with Amsler test examination and 50% with M-charts. Specificity of both tests was 100%. We found a significant difference between vertical scores of M-charts in all groups, but not in horizontal scores (p < 0.0001). Mean defect (MD) was 8.9 dB and 3.6 dB and loss variance (LV) 4.8 dB and 3.3 dB (p < 0.0001). Conclusions M-chart is more sensitive than Amsler test method for detection of metamorphopsia. The MD and LV are higher in b/y in comparison to W/W perimetry. B/Y perimetry and M-charts are more sensitive than conventional methods for detecting the visual function loss in cystoid DME. PMID:29744359

  15. Rapid pupil-based assessment of glaucomatous damage.

    PubMed

    Chen, Yanjun; Wyatt, Harry J; Swanson, William H; Dul, Mitchell W

    2008-06-01

    To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the "contrast balance" (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes.

  16. Rapid Pupil-Based Assessment of Glaucomatous Damage

    PubMed Central

    Chen, Yanjun; Wyatt, Harry J.; Swanson, William H.; Dul, Mitchell W.

    2010-01-01

    Purpose To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Methods Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the “contrast balance” (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Conclusions Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes. PMID:18521026

  17. Imaging atomic-scale effects of high-energy ion irradiation on superconductivity and vortex pinning in Fe(Se,Te)

    PubMed Central

    Massee, Freek; Sprau, Peter Oliver; Wang, Yong-Lei; Davis, J. C. Séamus; Ghigo, Gianluca; Gu, Genda D.; Kwok, Wai-Kwong

    2015-01-01

    Maximizing the sustainable supercurrent density, JC, is crucial to high-current applications of superconductivity. To achieve this, preventing dissipative motion of quantized vortices is key. Irradiation of superconductors with high-energy heavy ions can be used to create nanoscale defects that act as deep pinning potentials for vortices. This approach holds unique promise for high-current applications of iron-based superconductors because JC amplification persists to much higher radiation doses than in cuprate superconductors without significantly altering the superconducting critical temperature. However, for these compounds, virtually nothing is known about the atomic-scale interplay of the crystal damage from the high-energy ions, the superconducting order parameter, and the vortex pinning processes. We visualize the atomic-scale effects of irradiating FeSexTe1−x with 249-MeV Au ions and find two distinct effects: compact nanometer-sized regions of crystal disruption or “columnar defects,” plus a higher density of single atomic site “point” defects probably from secondary scattering. We directly show that the superconducting order is virtually annihilated within the former and suppressed by the latter. Simultaneous atomically resolved images of the columnar crystal defects, the superconductivity, and the vortex configurations then reveal how a mixed pinning landscape is created, with the strongest vortex pinning occurring at metallic core columnar defects and secondary pinning at clusters of point-like defects, followed by collective pinning at higher fields. PMID:26601180

  18. Imaging atomic-scale effects of high-energy ion irradiation on superconductivity and vortex pinning in Fe(Se,Te).

    PubMed

    Massee, Freek; Sprau, Peter Oliver; Wang, Yong-Lei; Davis, J C Séamus; Ghigo, Gianluca; Gu, Genda D; Kwok, Wai-Kwong

    2015-05-01

    Maximizing the sustainable supercurrent density, J C, is crucial to high-current applications of superconductivity. To achieve this, preventing dissipative motion of quantized vortices is key. Irradiation of superconductors with high-energy heavy ions can be used to create nanoscale defects that act as deep pinning potentials for vortices. This approach holds unique promise for high-current applications of iron-based superconductors because J C amplification persists to much higher radiation doses than in cuprate superconductors without significantly altering the superconducting critical temperature. However, for these compounds, virtually nothing is known about the atomic-scale interplay of the crystal damage from the high-energy ions, the superconducting order parameter, and the vortex pinning processes. We visualize the atomic-scale effects of irradiating FeSe x Te1-x with 249-MeV Au ions and find two distinct effects: compact nanometer-sized regions of crystal disruption or "columnar defects," plus a higher density of single atomic site "point" defects probably from secondary scattering. We directly show that the superconducting order is virtually annihilated within the former and suppressed by the latter. Simultaneous atomically resolved images of the columnar crystal defects, the superconductivity, and the vortex configurations then reveal how a mixed pinning landscape is created, with the strongest vortex pinning occurring at metallic core columnar defects and secondary pinning at clusters of point-like defects, followed by collective pinning at higher fields.

  19. Endoscopic Endonasal Optic Nerve Decompression for Fibrous Dysplasia

    PubMed Central

    DeKlotz, Timothy R.; Stefko, S. Tonya; Fernandez-Miranda, Juan C.; Gardner, Paul A.; Snyderman, Carl H.; Wang, Eric W.

    2016-01-01

    Objective To evaluate visual outcomes and potential complications for optic nerve decompression using an endoscopic endonasal approach (EEA) for fibrous dysplasia. Design Retrospective chart review of patients with fibrous dysplasia causing extrinsic compression of the canalicular segment of the optic nerve that underwent an endoscopic endonasal optic nerve decompression at the University of Pittsburgh Medical Center from 2010 to 2013. Main Outcome Measures The primary outcome measure assessed was best-corrected visual acuity (BCVA) with secondary outcomes, including visual field testing, color vision, and complications associated with the intervention. Results A total of four patients and five optic nerves were decompressed via an EEA. All patients were symptomatic preoperatively and had objective findings compatible with compressive optic neuropathy: decreased visual acuity was noted preoperatively in three patients while the remaining patient demonstrated an afferent pupillary defect. BCVA improved in all patients postoperatively. No major complications were identified. Conclusion EEA for optic nerve decompression appears to be a safe and effective treatment for patients with compressive optic neuropathy secondary to fibrous dysplasia. Further studies are required to identify selection criteria for an open versus an endoscopic approach. PMID:28180039

  20. Endoscopic Endonasal Approach for Resection of a Pediatric Craniopharyngioma: Operative Video and Technical Nuances.

    PubMed

    Liu, James K; Eloy, Jean Anderson

    2018-04-01

    We present a pediatric case of a retrochiasmatic craniopharyngioma in the suprasellar region with third ventricular extension that was resected through a purely endoscopic endonasal approach (EEA) via the transplanum transtuberculum corridor. The patient is a 12-year-old boy who presented with progressive visual loss and panhypopituitarism. The EEA allows direct visualization of the undersurface of the optic chiasm and hypothalamus so that safe and meticulous tumor dissection can be performed to preserve these critical neurovascular structures. This video atlas demonstrates the operative technique and surgical nuances of the endoscopic skull base approach, microdissection of the tumor from the critical neurovascular structures, and multilayered reconstruction of the skull base defect with a nasoseptal flap. A gross total resection was achieved, and the patient was neurologically intact with improved visual acuity and visual fields. In summary, the EEA via the transplanum transtuberculum corridor is an important strategy in the armamentarium for surgical management of pediatric craniopharyngiomas. The link to the video can be found at: https://youtu.be/bmgO_PMRHPk .

  1. Progression of Local Glaucomatous Damage Near Fixation as Seen with Adaptive Optics Imaging.

    PubMed

    Hood, Donald C; Lee, Dongwon; Jarukasetphon, Ravivarn; Nunez, Jason; Mavrommatis, Maria A; Rosen, Richard B; Ritch, Robert; Dubra, Alfredo; Chui, Toco Y P

    2017-07-01

    Deep glaucomatous defects near fixation were followed over time with an adaptive optics-scanning light ophthalmoscope (AO-SLO) to better understand the progression of these defects and to explore the use of AO-SLO in detecting them. Six eyes of 5 patients were imaged with an AO-SLO from 2 to 4 times for a range of 14.6 to 33.6 months. All eyes had open-angle glaucoma with deep defects in the superior visual field (VF) near fixation as defined by 10-2 VFs with 5 or more points less than -15 dB; two of the eyes had deep defects in the inferior VF as well. AO-SLO images were obtained around the temporal edge of the disc. In 4 of the 6 eyes, the edge of the inferior-temporal disc region of the retinal nerve fiber (RNF) defect seen on AO-SLO moved closer to fixation within 10.6 to 14.7 months. In 4 eyes, RNF bundles in the affected region appeared to lose contrast and/or disappear. Progressive changes in RNF bundles associated with deep defects on 10-2 VFs can be seen within about 1 year with AO-SLO imaging. These changes are well below the spatial resolution of the 10-2 VF. On the other hand, subtle thinning of regions with RNF bundles is not easy to see with current AO-SLO technology, and may be better followed with OCT. AO-SLO imaging may be useful in clinical trials designed to see very small changes in deep defects.

  2. Progressive Multifocal Leukoencephalopathy: Recent Advances and a Neuro-Ophthalmological Review.

    PubMed

    Sudhakar, Padmaja; Bachman, David M; Mark, Alexander S; Berger, Joseph R; Kedar, Sachin

    2015-09-01

    Progressive multifocal leukoencephalopathy (PML) is a severe often fatal opportunistic infection of the central nervous system caused by reactivation of a ubiquitous polyoma virus, JC virus. Although typically characterized by multifocal asymmetric subcortical white matter lesions, it may be monofocal and affect the cortical gray matter. Among the broad spectrum of clinical manifestations that occurs with PML, visual complaints are common. Combination of representative personally observed cases of PML and comprehensive review of case series of PML from 1958 through 2014. Neuro-ophthalmic signs and symptoms were reported in approximately 20%-50% of patients with PML and can be the presenting manifestation in half of these. A majority of these presentations occur from damage to cerebral visual pathways resulting in visual field defects, cortical blindness, and other disorders of visual association. Given the decreased frequency of infratentorial and cerebellar involvement, ocular motility disorders are less common. Visual complaints occur in patients with PML and are often the presenting sign. Awareness of this condition is helpful in avoiding unnecessary delays in the diagnosis of PML and management of the underlying condition. Recent guidelines have established criteria for diagnosis of PML in the high-risk patient population and strategies to mitigate the risk in these populations.

  3. Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

    NASA Astrophysics Data System (ADS)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Kasahara, Masayuki; Matsumura, Kazuhiro; Shimizu, Kimiya

    2016-05-01

    This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect, and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower, and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.

  4. Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields

    PubMed Central

    Vaz, Fernando T; Ramalho, Mário; Pedrosa, Catarina; Lisboa, Maria; Kaku, Paulo; Esperancinha, Florindo

    2016-01-01

    Aim To determine the relationship between macular thickness (MT) and visual field (VF) parameters, as well as with changes in the retinal nerve fiber layer (RNFL) thickness in patients with glaucoma and ocular hypertension (OH). Materials and methods Cross-sectional statistical analysis of spectral domain optical coherence tomography (SD-OCT) compared with several VF parameters (mean defect - MD and loss variance - LV), in a nonrandom sample of 70 eyes from patients with glaucoma or OH. Statistical analysis was performed using Statistical Package for Social Sciences®. The correlation coefficient used was determined by Spearman correlation and the value of p < 0.05 was considered statistically significant. Results A significant correlation was seen between VF parameters and decrease in MT (MD: r = –0.363, p = 0.002; LV: r=–0.378, p = 0.001). The results were more significant when we compared the LV in the group with average MT 270 to 300 μm (r = –0.413, p = 0.015). Asymmetry between the superior macula and inferior macula correlated with LV (r = 0.432, p = 0.019) in the group with MT < 270 μm. There was also a significant correlation between thinning of superior-temporal and inferior-temporal RNFL and the decrease of the superior and inferior MT respectively (p < 0.001). Conclusion Spectral domain optical coherence tomography measurements of retinal thickness in the macula correlate with VF parameters and RNFL parameters in glaucoma patients. This relationship was first demonstrated with static computerized perimetry made with Octopus 101®. These results can be a valuable aid for evaluating and monitoring of glaucoma patients, establishing a correlation between structure and function. Measurements of retinal thickness in the macula may be an additional instrument for early detection of structural changes and its correlation with functional defects. How to cite this article Mota M, Vaz FT, Ramalho M, Pedrosa C, Lisboa M, Kaku P, Esperancinha F. Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields. J Curr Glaucoma Pract 2016;10(3):85-90. PMID:27857487

  5. High-throughput behavioral screening method for detecting auditory response defects in zebrafish.

    PubMed

    Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F

    2002-08-30

    We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.

  6. Nondestructive rule-based defect detection and identification system in CT images of hardwood logs

    Treesearch

    Erol Sarigul; A. Lynn Abbott; Daniel L. Schmoldt

    2001-01-01

    This paper is concerned with the detection of internal defects in hardwood logs. Because the commercial value of hardwood lumber is directly related to the quantity, type, and location of defects in the wood, sawing strategies are typically chosen in an attempt to minimize the defects in the resulting boards. Traditionally, the sawyer makes sawing decisions by visually...

  7. Detecting vortices in superconductors: Extracting one-dimensional topological singularities from a discretized complex scalar field

    DOE PAGES

    Phillips, Carolyn L.; Peterka, Tom; Karpeyev, Dmitry; ...

    2015-02-20

    In type II superconductors, the dynamics of superconducting vortices determine their transport properties. In the Ginzburg-Landau theory, vortices correspond to topological defects in the complex order parameter. Extracting their precise positions and motion from discretized numerical simulation data is an important, but challenging, task. In the past, vortices have mostly been detected by analyzing the magnitude of the complex scalar field representing the order parameter and visualized by corresponding contour plots and isosurfaces. However, these methods, primarily used for small-scale simulations, blur the fine details of the vortices, scale poorly to large-scale simulations, and do not easily enable isolating andmore » tracking individual vortices. In this paper, we present a method for exactly finding the vortex core lines from a complex order parameter field. With this method, vortices can be easily described at a resolution even finer than the mesh itself. The precise determination of the vortex cores allows the interplay of the vortices inside a model superconductor to be visualized in higher resolution than has previously been possible. Finally, by representing the field as the set of vortices, this method also massively reduces the data footprint of the simulations and provides the data structures for further analysis and feature tracking.« less

  8. Visual function of children with visual and other disabilities in Oman: A case series.

    PubMed

    Gogri, Urmi; Khandekar, Rajiv; Al Harby, Salah

    2016-12-01

    We assessed the visual functioning of the children with special needs in Oman between 2009 and 2012. We present the methods of assessing different visual functions, outcomes, and interventions carried out to improve their functioning. Optometrists assessed visual functions of children of "Day care centres" in Oman. Experts further assessed them and provided low vision care. Ocular movements, refractive corrections, near, distance, contrast color, motion, field of vision, and cognitive visual function test results were noted. Feedback to caregivers was given to improve visual functioning of these children. We grouped 321 participants, (196 [61.1%] boys, age range of 3-18 years) into 61; Down syndrome (DS), 72 with intellectual disabilities (IDs), 67; hearing impaired and 121 with other conditions. Refractive error and lag of accommodation were 26 (42.6%) and 14 (22.6%) among children with DS. Contrast sensitivity was impaired in 8 (12.7%) among hearing impaired children. Defective distant and near vision was in 162 (70%) and 104 (42%) of our cohort. Children with ID were most difficult to assess. Children in a group of other disabilities had a higher proportion of impaired visual functioning. They were given low vision aids (telescopes [22], filters [7], and magnifiers [3]) in large numbers compared to those in other groups. Visual functioning of children with other disabilities show great variation and difficult to group. The care, therefore, should be at individual level. All visual functions cannot be assessed at one time.

  9. An interdisciplinary visual team in an acute and sub-acute stroke unit: Providing assessment and early rehabilitation.

    PubMed

    Norup, Anne; Guldberg, Anne-Mette; Friis, Claus Radmer; Deurell, Eva Maria; Forchhammer, Hysse Birgitte

    2016-07-15

    To describe the work of an interdisciplinary visual team in a stroke unit providing early identification and assessment of patients with visual symptoms, and secondly to investigate frequency, type of visual deficits after stroke and self-evaluated impact on everyday life after stroke. For a period of three months, all stroke patients with visual or visuo-attentional deficits were registered, and data concerning etiology, severity and localization of the stroke and initial visual symptoms were registered. One month after discharge patients were contacted for follow-up. Of 349 acute stroke admissions, 84 (24.1%) had visual or visuo-attentional deficits initially. Of these 84 patients, informed consent was obtained from 22 patients with a mean age of 67.7 years(SD 10.1), and the majority was female (59.1%). Based on the initial neurological examination, 45.4% had some kind of visual field defect, 27.2% had some kind of oculomotor nerve palsy, and about 31.8% had some kind of inattention or visual neglect. The patients were contacted for a phone-based follow-up one month after discharge, where 85.7% reported changes in their vision since their stroke. In this consecutive sample, a quarter of all stroke patients had visual or visuo-attentional deficits initially. This emphasizes how professionals should have increased awareness of the existence of such deficits after stroke in order to provide the necessary interdisciplinary assessment and rehabilitation.

  10. Extraction of thermal Green's function using diffuse fields: a passive approach applied to thermography

    NASA Astrophysics Data System (ADS)

    Capriotti, Margherita; Sternini, Simone; Lanza di Scalea, Francesco; Mariani, Stefano

    2016-04-01

    In the field of non-destructive evaluation, defect detection and visualization can be performed exploiting different techniques relying either on an active or a passive approach. In the following paper the passive technique is investigated due to its numerous advantages and its application to thermography is explored. In previous works, it has been shown that it is possible to reconstruct the Green's function between any pair of points of a sensing grid by using noise originated from diffuse fields in acoustic environments. The extraction of the Green's function can be achieved by cross-correlating these random recorded waves. Averaging, filtering and length of the measured signals play an important role in this process. This concept is here applied in an NDE perspective utilizing thermal fluctuations present on structural materials. Temperature variations interacting with thermal properties of the specimen allow for the characterization of the material and its health condition. The exploitation of the thermographic image resolution as a dense grid of sensors constitutes the basic idea underlying passive thermography. Particular attention will be placed on the creation of a proper diffuse thermal field, studying the number, placement and excitation signal of heat sources. Results from numerical simulations will be presented to assess the capabilities and performances of the passive thermal technique devoted to defect detection and imaging of structural components.

  11. The design of 3D scaffold for tissue engineering using automated scaffold design algorithm.

    PubMed

    Mahmoud, Shahenda; Eldeib, Ayman; Samy, Sherif

    2015-06-01

    Several progresses have been introduced in the field of bone regenerative medicine. A new term tissue engineering (TE) was created. In TE, a highly porous artificial extracellular matrix or scaffold is required to accommodate cells and guide their growth in three dimensions. The design of scaffolds with desirable internal and external structure represents a challenge for TE. In this paper, we introduce a new method known as automated scaffold design (ASD) for designing a 3D scaffold with a minimum mismatches for its geometrical parameters. The method makes use of k-means clustering algorithm to separate the different tissues and hence decodes the defected bone portions. The segmented portions of different slices are registered to construct the 3D volume for the data. It also uses an isosurface rendering technique for 3D visualization of the scaffold and bones. It provides the ability to visualize the transplanted as well as the normal bone portions. The proposed system proves good performance in both the segmentation results and visualizations aspects.

  12. The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

    NASA Technical Reports Server (NTRS)

    Athale, R.; Lee, S. H.

    1976-01-01

    Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

  13. IgG4-related cerebral pseudotumor with perineural spreading along branches of the trigeminal nerves causing compressive optic neuropathy: A case report.

    PubMed

    Wu, Po-Chang; Tien, Peng-Tai; Li, Ying-Hsuan; Chen, Rui-Yun; Cho, Der-Yang

    2017-11-01

    Immunoglobulin G4-related disease (IgG4-RD) is characterized by tumor-like lesions, a dense lymphoplasmacytic infiltrate rich in IgG4-positive plasma cells, storiform fibrosis, and obliterative phlebitis. IgG4-RD has been described in a variety of organ systems; however, it rarely involves the central nervous system. A 17-year-old woman visited our clinic with a complaint of blurred vision for the past 5 months. She also reported a painless right submandibular mass that had been present for 1 year. Her best-corrected visual acuity (BCVA) was 2.0 LogMAR, with an almost total visual field defect in the right eye. Magnetic resonance imaging (MRI) revealed lobulated parasellar tumors with perineural spreading along branches of the trigeminal nerves causing right optic nerve compression. A craniotomy with tumor removal and submandibular gland biopsy was performed. Histopathological analysis of the tumor revealed stromal fibrosis with atypical lymphoid infiltrations. Histopathological and immunohistochemical analysis of the submandibular gland confirmed the diagnosis of IgG4-RD. The patient was administered 500mg/d of pulse methylprednisolone for 3 days, 500mg of intravenous rituximab every 2 weeks (for a total of 2 doses), and 500mg of intravenous pulse cyclophosphamide every month (for a total of 3 doses). Two months after the initiation of immunosuppressive therapy, the patient's BCVA returned to 0.1 LogMAR with visual field defect recovery. The follow-up MRI showed the almost complete disappearance of the previously contrast-enhanced lesions. Herein, we report a rare case of IgG4-RD presenting as a parasellar tumor and present a review of the related literature. Based on the case report, we propose that aggressive therapy with glucocorticoid, rituximab, and cyclophosphamide may potentially be useful for treating such cases. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  14. Clinical predictors of advanced sellar masses.

    PubMed

    Rambaldini, Gloria M; Butalia, Sonia; Ezzat, Shereen; Kucharczyk, Walter; Sawka, Anna M

    2007-10-01

    To identify clinical variables associated with the presence of a structurally advanced sellar mass (ASM). We performed a retrospective study of patients referred for evaluation of suspected new pituitary disease or sellar mass to the Endocrine Oncology Unit of Mount Sinai Hospital in Toronto, Ontario, Canada. By multivariate analysis, we examined predictors of a structurally ASM (a sellar lesion with any of the following characteristics: diameter of >or=1 cm on magnetic resonance imaging [MRI], optic chiasmal compression on MRI, or clinical or biochemical evidence of hypopituitarism). Data from 152 patients were analyzed. Of the 152 sellar masses, 142 (93%) were pituitary adenomas. An ASM was noted in 85 of the 152 patients (56%). In the final multivariate model, male sex (odds ratio [OR], 6.23; 95% confidence interval [CI], 2.84 to 13.56; P<0.001) and self-reported visual field defect (OR, 3.62; 95% CI, 1.07 to 12.25; P = 0.039) were significantly independently associated with the presence of an ASM. The presence of new or changed headaches also tended to be associated with an ASM (OR, 2.11; 95% CI, 0.96 to 4.64; P = 0.063). Age and self-reported galactorrhea were not independently associated with the presence of an ASM and were conditionally removed from the final model. In patients with suspected sellar or pituitary disease, male sex and self-reported visual field defects independently predict the presence of an ASM. New or changed headaches also tend to be related to the presence of an ASM. The presence of predictors of an ASM should prompt expedited sellar MRI and biochemical evaluation.

  15. Field defects in progression to gastrointestinal tract cancers

    PubMed Central

    Bernstein, Carol; Bernstein, Harris; Payne, Claire M.; Dvorak, Katerina; Garewal, Harinder

    2009-01-01

    A field of defective tissue may represent a pre-malignant stage in progression to many cancers. However, field defects are often overlooked in studies of cancer progression through assuming tissue at some distance from the cancer is normal. We indicate, however, the generality of field defects in gastrointestinal cancers, including cancers of the oropharynx, esophagus, stomach, bile duct, pancreas, small intestine and colon/rectum. Common features of these field defects are reduced apoptosis competence, aberrant proliferation and genomic instability. These features are often associated with high bile acid exposure and may explain the association of dietary-related factors with cancer progression. PMID:18164807

  16. Diagnostic Value of Ganglion Cell-Inner Plexiform Layer Thickness in Glaucoma With Superior or Inferior Visual Hemifield Defects.

    PubMed

    Kim, Ho Soong; Yang, Heon; Lee, Tae Heon; Lee, Kyung Heon

    2016-06-01

    To determine the diagnostic value of the ganglion cell-inner plexiform layer (GCIPL) thickness in glaucomatous eyes with superior or inferior visual hemifield defects. Eighty-five patients with glaucoma (42 isolated superior hemifield defects and 43 isolated inferior hemifield defects) and 46 normal subjects were enrolled. All patients underwent Cirrus high-definition optical coherence tomography and standard automated perimetry. The area under the receiver operating characteristic curve (AUC) was calculated to determine the diagnostic ability of the GCIPL and peripapillary retinal nerve fiber layer (pRNFL). In the superior hemifield defect glaucoma group, the best parameters for discriminating normal eyes from glaucomatous eyes were the inferotemporal GCIPL thickness (0.942), inferior quadrant RNFL thickness (0.974), and 7 o'clock sector RNFL thickness (0.999). For diagnosing inferior hemifield defect glaucoma, the AUCs of all GCIPL parameters (0.331 to 0.702) were significantly lower than that of the superior quadrant RNFL thickness (0.866, P<0.05). The diagnostic ability of GCIPL parameters was similar to that of the pRNFL parameters in superior hemifield defect glaucoma. However, the diagnostic performance of the GCIPL parameters was significantly inferior to those of the pRNFL parameters in eyes with inferior hemifield defect glaucoma.

  17. STRUCTURAL AND FUNCTIONAL CHARACTERIZATION OF BENIGN FLECK RETINA USING MULTIMODAL IMAGING.

    PubMed

    Neriyanuri, Srividya; Rao, Chetan; Raman, Rajiv

    2017-01-01

    To report structural and functional features in a case series of benign fleck retina using multimodal imaging. Four cases with benign fleck retina underwent complete ophthalmic examination that included detailed history, visual acuity, and refractive error testing, FM-100 hue test, dilated fundus evaluation, full field electroretinogram, fundus photography with autofluorescence, fundus fluorescein angiography, and swept-source optical coherence tomography. Age group of the cases ranged from 19 years to 35 years (3 males and 1 female). Parental consanguinity was reported in two cases. All of them were visually asymptomatic with best-corrected visual acuity of 20/20 (moderate astigmatism) in both the eyes. Low color discrimination was seen in two cases. Fundus photography showed pisciform flecks which were compactly placed on posterior pole and were discrete, diverging towards periphery. Lesions were seen as smaller dots within 1500 microns from fovea and were hyperfluorescent on autofluorescence. Palisading retinal pigment epithelium defects were seen in posterior pole on fundus fluorescein angiography imaging; irregular hyper fluorescence was also noted. One case had reduced cone responses on full field electroretinogram; the other three cases had normal electroretinogram. On optical coherence tomography, level of lesions varied from retinal pigment epithelium, inner segment to outer segment extending till external limiting membrane. Functional and structural deficits in benign fleck retina were picked up using multimodal imaging.

  18. [A rare cause of optic neuropathy: Cassava].

    PubMed

    Zeboulon, P; Vignal-Clermont, C; Baudouin, C; Labbé, A

    2016-06-01

    Cassava root is a staple food for almost 500 million people worldwide. Excessive consumption of it is a rare cause of optic neuropathy. Ten patients diagnosed with cassava root related optic neuropathy were included in this retrospective study. Diagnostic criteria were a bilateral optic neuropathy preceded by significant cassava root consumption. Differential diagnoses were excluded through a neuro-ophthalmic examination, blood tests and a brain MRI. All patients had visual field examination and OCT retinal nerve fiber layer (RNFL) analysis as well as an evaluation of their cassava consumption. All patients had a bilateral optic nerve head atrophy or pallor predominantly located into the temporal sector. Visual field defects consisted of a central or cecocentral scotoma for all patients. RNFL showed lower values only in the temporal sector. Mean duration of cassava consumption prior to the appearance of visual symptoms was 22.7±11.2 years with a mean of 2.57±0.53 cassava-based meals per week. Cassava related optic neuropathy is possibly due to its high cyanide content and enabled by a specific amino-acid deficiency. Cassava root chronic consumption is a rare, underappreciated cause of optic neuropathy and its exact mechanism is still uncertain. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Defect-selective dry etching for quick and easy probing of hexagonal boron nitride domains.

    PubMed

    Wu, Qinke; Lee, Joohyun; Park, Sangwoo; Woo, Hwi Je; Lee, Sungjoo; Song, Young Jae

    2018-03-23

    In this study, we demonstrate a new method to selectively etch the point defects or the boundaries of as-grown hexagonal boron nitride (hBN) films and flakes in situ on copper substrates using hydrogen and argon gases. The initial quality of the chemical vapor deposition-grown hBN films and flakes was confirmed by UV-vis absorption spectroscopy, atomic force microscopy, and transmission electron microscopy. Different gas flow ratios of Ar/H 2 were then employed to etch the same quality of samples and it was found that etching with hydrogen starts from the point defects and grows epitaxially, which helps in confirming crystalline orientations. However, etching with argon is sensitive to line defects (boundaries) and helps in visualizing the domain size. Finally, based on this defect-selective dry etching technique, it could be visualized that the domains of a polycrystalline hBN monolayer merged together with many parts, even with those that grew from a single nucleation seed.

  20. Defect-selective dry etching for quick and easy probing of hexagonal boron nitride domains

    NASA Astrophysics Data System (ADS)

    Wu, Qinke; Lee, Joohyun; Park, Sangwoo; Woo, Hwi Je; Lee, Sungjoo; Song, Young Jae

    2018-03-01

    In this study, we demonstrate a new method to selectively etch the point defects or the boundaries of as-grown hexagonal boron nitride (hBN) films and flakes in situ on copper substrates using hydrogen and argon gases. The initial quality of the chemical vapor deposition-grown hBN films and flakes was confirmed by UV-vis absorption spectroscopy, atomic force microscopy, and transmission electron microscopy. Different gas flow ratios of Ar/H2 were then employed to etch the same quality of samples and it was found that etching with hydrogen starts from the point defects and grows epitaxially, which helps in confirming crystalline orientations. However, etching with argon is sensitive to line defects (boundaries) and helps in visualizing the domain size. Finally, based on this defect-selective dry etching technique, it could be visualized that the domains of a polycrystalline hBN monolayer merged together with many parts, even with those that grew from a single nucleation seed.

  1. An Automated Classification Technique for Detecting Defects in Battery Cells

    NASA Technical Reports Server (NTRS)

    McDowell, Mark; Gray, Elizabeth

    2006-01-01

    Battery cell defect classification is primarily done manually by a human conducting a visual inspection to determine if the battery cell is acceptable for a particular use or device. Human visual inspection is a time consuming task when compared to an inspection process conducted by a machine vision system. Human inspection is also subject to human error and fatigue over time. We present a machine vision technique that can be used to automatically identify defective sections of battery cells via a morphological feature-based classifier using an adaptive two-dimensional fast Fourier transformation technique. The initial area of interest is automatically classified as either an anode or cathode cell view as well as classified as an acceptable or a defective battery cell. Each battery cell is labeled and cataloged for comparison and analysis. The result is the implementation of an automated machine vision technique that provides a highly repeatable and reproducible method of identifying and quantifying defects in battery cells.

  2. Characteristics and Ophthalmic Manifestations of the Classic Dengue Fever Epidemic in Singapore (2005-2006).

    PubMed

    Koh, Yan Tong; Sanjay, Srinivasan

    2013-01-01

    The aim of this study was to report the characteristics and ophthalmic manifestations associated with dengue fever (DF) in the 2005-2006 DF epidemic in Singapore. A retrospective case series. Eleven patients (7 males, 4 females) who were 14 to 40 years old (mean age, 27.3 years) with visual complaints occurring 1 to 2 weeks after the onset of DF underwent a complete ophthalmologic examination. The presenting visual acuity (VA) ranged from 6/6 to counting fingers. Five patients had bilateral eye involvement. Ophthalmic findings included retinal hemorrhages (15 eyes), cotton wool spots (15 eyes), retinal pigment epithelium alterations (5 eyes), optic disc swelling (3 eyes), foveolitis (3 eyes), and hyperemia (2 eyes). Impaired color vision was noted in 12 eyes. Visual field defects were noted in 13 eyes; 4 of these eyes were asymptomatic. Fundus fluorescein angiography was done in 9 patients; the findings include choroidal hyperfluorescence (9 eyes), blocked fluorescence (8 eyes), and capillary nonperfusion (1 eye). In 2 eyes, it was normal. Electrophysiology confirmed optic neuropathy in 3 eyes and maculopathy in 1 eye. The follow-up ranged from 12 days to 12 months. The VA at the last follow-up ranged from no light perception to 6/6. Visual field abnormalities were noted in 5 eyes despite a normal VA. Dengue fever is associated with a wide spectrum of ophthalmic manifestations. Rarely, ophthalmic complications in DF can result in permanent visual impairment. Further work can be done to elucidate the relationship between systemic and ocular manifestations of DF.

  3. When apperceptive agnosia is explained by a deficit of primary visual processing.

    PubMed

    Serino, Andrea; Cecere, Roberto; Dundon, Neil; Bertini, Caterina; Sanchez-Castaneda, Cristina; Làdavas, Elisabetta

    2014-03-01

    Visual agnosia is a deficit in shape perception, affecting figure, object, face and letter recognition. Agnosia is usually attributed to lesions to high-order modules of the visual system, which combine visual cues to represent the shape of objects. However, most of previously reported agnosia cases presented visual field (VF) defects and poor primary visual processing. The present case-study aims to verify whether form agnosia could be explained by a deficit in basic visual functions, rather that by a deficit in high-order shape recognition. Patient SDV suffered a bilateral lesion of the occipital cortex due to anoxia. When tested, he could navigate, interact with others, and was autonomous in daily life activities. However, he could not recognize objects from drawings and figures, read or recognize familiar faces. He was able to recognize objects by touch and people from their voice. Assessments of visual functions showed blindness at the centre of the VF, up to almost 5°, bilaterally, with better stimulus detection in the periphery. Colour and motion perception was preserved. Psychophysical experiments showed that SDV's visual recognition deficits were not explained by poor spatial acuity or by the crowding effect. Rather a severe deficit in line orientation processing might be a key mechanism explaining SDV's agnosia. Line orientation processing is a basic function of primary visual cortex neurons, necessary for detecting "edges" of visual stimuli to build up a "primal sketch" for object recognition. We propose, therefore, that some forms of visual agnosia may be explained by deficits in basic visual functions due to widespread lesions of the primary visual areas, affecting primary levels of visual processing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Electric Field Simulation of Surge Capacitors with Typical Defects

    NASA Astrophysics Data System (ADS)

    Zhang, Chenmeng; Mao, Yuxiang; Xie, Shijun; Zhang, Yu

    2018-03-01

    The electric field of power capacitors with different typical defects in DC working condition and impulse oscillation working condition is studied in this paper. According to the type and location of defects and considering the influence of space charge, two-dimensional models of surge capacitors with different typical defects are simulated based on ANSYS. The distribution of the electric field inside the capacitor is analyzed, and the concentration of electric field and its influence on the insulation performance are obtained. The results show that the type of defects, the location of defects and the space charge all affect the electric field distribution inside the capacitor in varying degrees. Especially the electric field distortion in the local area such as sharp corners and burrs is relatively larger, which increases the probability of partial discharge inside the surge capacitor.

  5. Evaluating Glaucomatous Retinal Nerve Fiber Damage by GDx VCC Polarimetry in Taiwan Chinese Population

    PubMed Central

    Chen, Hsin-Yi; Huang, Mei-Ling; Huang, Wei-Cheng

    2010-01-01

    Purpose To study the capability of scanning laser polarimetry with variable corneal compensation (GDx VCC) to detect differences in retinal nerve fiber layer thickness between normal and glaucomatous eyes in a Taiwan Chinese population. Methods This study included 44 normal eyes and 107 glaucomatous eyes. The glaucomatous eyes were divided into three subgroups on the basis of its visual field defects (early, moderate, severe). Each subject underwent a GDx-VCC exam and visual field testing. The area under the receiver-operating characteristic curve (AROC) of each relevant parameter was used to differentiate normal from each glaucoma subgroup, respectively. The correlation between visual field index and each parameter was evaluated for the eyes in the glaucoma group. Results For normal vs. early glaucoma, the parameter with the best AROC was Nerve fiber indicator (NFI) (0.942). For normal vs. moderate glaucoma, the parameter showing the best AROC was NFI (0.985). For normal vs. severe glaucoma, the parameter that had the best AROC was NFI (1.000). For early vs. moderate glaucoma, the parameter with the best AROC was NFI (0.732). For moderate vs. severe, the parameter showing the best AROC was temporal-superior-nasal-inferior-temporal average (0.652). For early vs. severe, the parameter with the best AROC was NFI (0.852). Conclusions GDx-VCC-measured parameters may serve as a useful tool to distinguish normal from glaucomatous eyes; in particular, NFI turned out to be the best discriminating parameter.

  6. Defect dynamics and coarsening dynamics in smectic-C films

    NASA Astrophysics Data System (ADS)

    Pargellis, A. N.; Finn, P.; Goodby, J. W.; Panizza, P.; Yurke, B.; Cladis, P. E.

    1992-12-01

    We study the dynamics of defects generated in free-standing films of liquid crystals following a thermal quench from the smectic-A phase to the smectic-C phase. The defects are type-1 disclinations, and the strain field between defect pairs is confined to 2π walls. We compare our observations with a phenomenological model that includes dipole coupling of the director field to an external ordering field. This model is able to account for both the observed coalescence dynamics and the observed ordering dynamics. In the absence of an ordering field, our model predicts the defect density ρ to scale with time t as ρ lnρ~t-1. When the dipole coupling of the director field to an external ordering field is included, both the model and experiments show the defect coarsening proceeds as ρ~e-αt with the strain field confined to 2π walls. The external ordering field most likely arises from the director's tendency to align with edge dislocations within the liquid-crystal film.

  7. Peripapillary and Macular Vessel Density in Glaucoma Patients with Single-Hemifield Visual Field Defect

    PubMed Central

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Saunders, Luke J.; Suh, Min Hee; Wu, Zhichao; Manalastas, Patricia Isabel C.; Akagi, Tadamichi; Medeiros, Felipe A.; Weinreb, Robert N.

    2017-01-01

    Purpose To compare hemifield differences in the vessel density of the optic nerve head and macula in open-angle glaucoma (OAG) eyes with visual field (VF) defect confined to one hemifield using optical coherence tomography angiography (OCT-A). Design Cross-sectional study. Participants Fifty-eight eyes of 58 glaucoma patients with VF loss confined to a single hemifield, and 28 healthy eyes. Methods Retinal vasculature information was summarized as circumpapillary vessel density (cpVD) and perifoveal vessel density (pfVD). Circumpapillary retinal nerve fiber layer (cpRNFL) and macular ganglion cell complex (mGCC) thickness were also calculated using spectral domain OCT. Paired and unpaired t-tests were utilized to evaluate differences between the perimetrically affected and intact hemiretinae and healthy hemiretinae. Linear regression analyses were performed to evaluate the associations between VF measures with vascular and structural measurements. Main Outcome Measures Total and hemispheric cpVD, pfVD, cpRNFL, mGCC and mean sensitivity (MS). Results Mean cpVD and pfVD in the intact hemiretinae of OAG eyes (59.0% and 51.1%) were higher than the affected hemiretinae (54.7% and 48.3%; p<0.001) but lower than healthy eyes (62.4% and 53.8%; p<0.001). Similar results were noted with cpRNFL and mGCC thickness measurements (p<0.05 for both). The strongest associations between MS in the affected hemifields were found for cpVD (r = 0.707), followed by pfVD (r = 0.615), cpRNFL (r = 0.496) and mGCC (r = 0.482) in the corresponding hemiretinae (p<0.001 for all). Moreover the correlations in the intact hemifields between MS with cpVD and pfVD were found to be higher (r = 0.450 and 0.403) than the correlations between MS and cpRNFL and mGCC thickness measurements (r = 0.340 and 0.290; all p-values <0.05 for all). Conclusions Reduced peripapillary and macular vessel density was detectable in the perimetrically intact hemiretinae of glaucoma eyes with a single-hemifield defect. Moreover vessel density attenuation in both affected and intact hemiretinae was associated with the extent of VF damage in the corresponding hemifields. OCT-A potentially shows promise for identifying glaucomatous damage before focal VF defects are detectable. PMID:28196732

  8. 9 CFR 318.301 - Containers and closures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 318.301 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... examinations for rigid containers (cans)—(1) Visual examinations. A closure technician shall visually examine... container shall be examined for product leakage or obvious defects. A visual examination shall be performed...

  9. [Assessment of the macula function by static perimetry, microperimetry and rarebit perimetry in patients suffering from dry age related macular degeneration].

    PubMed

    Nowomiejska, Katarzyna; Oleszczuk, Agnieszka; Zubilewicz, Anna; Krukowski, Jacek; Mańkowska, Anna; Rejdak, Robert; Zagórski, Zbigniew

    2007-01-01

    To compare the visual field results obtained by static perimetry, microperimetry and rabbit perimetry in patients suffering from dry age related macular degeneration (AMD). Fifteen eyes with dry AMD (hard or soft macula drusen and RPE disorders) were enrolled into the study. Static perimetry was performed using M2 macula program included in Octopus 101 instrument. Microperimetry was performed using macula program (14-2 threshold, 10dB) within 10 degrees of the central visual field. The fovea program within 4 degrees was used while performing rarebit perimetry. The mean sensitivity was significantly lower (p<0.001) during microperimetry (13.5 dB) comparing to static perimetry (26.7 dB). The mean deviation was significantly higher (p<0.001) during microperimetry (-6.32 dB) comparing to static perimetry (-3.11 dB). The fixation was unstable in 47% and eccentric in 40% while performing microperimetry. The median of the "mean hit rate" in rarebit perimetry was 90% (range 40-100%). The mean examination duration was 6.5 min. in static perimetry, 10.6 min. in microperimetry and 5,5 min. in rarebit perimetry (p<0.001). Sensitivity was 30%, 53% and 93% respectively. The visual field defects obtained by microperimetry were more pronounced than those obtained by static perimetry. Microperimetry was the most sensitive procedure although the most time-consuming. Microperimetry enables the control of the fixation position and stability, that is not possible using the remaining methods. Rarebit perimetry revealed slight reduction of the integrity of neural architecture of the retina. Microperimetry and rarebit perimetry provide more information in regard to the visual function than static perimetry, thus are the valuable method in the diagnosis of dry AMD.

  10. Concentric retinitis pigmentosa: clinicopathologic correlations.

    PubMed

    Milam, A H; De Castro, E B; Smith, J E; Tang, W X; John, S K; Gorin, M B; Stone, E M; Aguirre, G D; Jacobson, S G

    2001-10-01

    Progressive concentric (centripetal) loss of vision is one pattern of visual field loss in retinitis pigmentosa. This study provides the first clinicopathologic correlations for this form of retinitis pigmentosa. A family with autosomal dominant concentric retinitis pigmentosa was examined clinically and with visual function tests. A post-mortem eye of an affected 94 year old family member was processed for histopathology and immunocytochemistry with retinal cell specific antibodies. Unrelated simplex/multiplex patients with concentric retinitis pigmentosa were also examined. Affected family members of the eye donor and patients from the other families had prominent peripheral pigmentary retinopathy with more normal appearing central retina, good visual acuity, concentric field loss, normal or near normal rod and cone sensitivity within the preserved visual field, and reduced rod and cone electroretinograms. The eye donor, at age 90, had good acuity and function in a central island. Grossly, the central region of the donor retina appeared thinned but otherwise normal, while the far periphery contained heavy bone spicule pigment. Microscopically the central retina showed photoreceptor outer segment shortening and some photoreceptor cell loss. The mid periphery had a sharp line of demarcation where more central photoreceptors were near normal except for very short outer segments and peripheral photoreceptors were absent. Rods and cones showed abrupt loss of outer segments and cell death at this interface. It is concluded that concentric retinitis pigmentosa is a rare but recognizable phenotype with slowly progressive photoreceptor death from the far periphery toward the central retina. The disease is retina-wide but shows regional variation in severity of degeneration; photoreceptor death is severe in the peripheral retina with an abrupt edge between viable and degenerate photoreceptors. Peripheral to central gradients of unknown retinal molecule(s) may be defective or modify photoreceptor degeneration in concentric retinitis pigmentosa.

  11. Development and Evaluation of a Contrast Sensitivity Perimetry Test for Patients with Glaucoma

    PubMed Central

    Hot, Aliya; Dul, Mitchell W.; Swanson, William H.

    2008-01-01

    Purpose To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. Methods Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4° circular region. Threshold was estimated by a staircase method. Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24−2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test–retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area. Results Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001). Conclusions The implementation of CSP was successful in reducing test–retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area. PMID:18378580

  12. Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.

    PubMed

    Hot, Aliya; Dul, Mitchell W; Swanson, William H

    2008-07-01

    To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4 degrees circular region. Threshold was estimated by a staircase method: Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24-2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test-retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area. Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001). The implementation of CSP was successful in reducing test-retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area.

  13. [Comparing the ranges of defect measured with standard white on white and Pulsar perimetries].

    PubMed

    González de la Rosa, M; González-Hernández, M; García-Feijoo, J; Sánchez Méndez, M; García-Sánchez, J

    2011-04-01

    Normal thresholds on Pulsar perimetry fall faster than those of standard perimetry in the peripheral visual field. Two related studies were performed. Firstly, the frequency distributions of glaucoma defects on standard automated perimetry (SAP) and the relationship of the centre and periphery (Study A) were studied first, followed by an attempt to establish the limits of pulsar perimetry (Study B). A: frequency of defects was calculated in 78.663 SAP perimetries (G1-TOP, Octopus 1-2-3, Haag-Streit). Study B: 204 eyes with mean defect (MD-SAP) lower than 9 dB were examined 8.92 ± 4.19 times with SAP (TOP-32, Octopus 311) and temporal modulation perimetry (T30W, Pulsar Perimeter, Haag-Streit). Study A: 50.7% of the SAP examinations showed MD values lower than 9 dB and 32.7% bellow 6 dB. The MD correlation of the central 20° with the MD of the most peripheral points was r=0.933. Study B: in cases with MD-TOP-32 lower than 6 dB, SAP had the maximum possibility of detecting defect in 0.02% of points and Pulsar in 0.29%. In subjects with MD-TOP-32 between 6 and 9 dB frequencies were 0.38% in SAP and 3.5% in Pulsar (5.1% for eccentricities higher than 20°). Pulsar allows detecting defects, without range limitations, in the initial half of SAP frequencies expected on glaucoma patients. In order to study the progression of deeper defects the examination should focus on the central points, where the dynamic range of both systems is more equivalent. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  14. Identification of characteristic frequencies of damaged railway tracks using field hammer test measurements

    NASA Astrophysics Data System (ADS)

    Oregui, M.; Li, Z.; Dollevoet, R.

    2015-03-01

    In this paper, the feasibility of the Frequency Response Function (FRF)-based statistical method to identify the characteristic frequencies of railway track defects is studied. The method compares a damaged track state to a healthy state based on non-destructive field hammer test measurements. First, a study is carried out to investigate the repeatability of hammer tests in railway tracks. By changing the excitation and measurement locations it is shown that the variability introduced by the test process is negligible. Second, following the concepts of control charts employed in process monitoring, a method to define an approximate healthy state is introduced by using hammer test measurements at locations without visual damage. Then, the feasibility study includes an investigation into squats (i.e. a major type of rail surface defect) of varying severity. The identified frequency ranges related to squats agree with those found in an extensively validated vehicle-borne detection system. Therefore, the FRF-based statistical method in combination with the non-destructive hammer test measurements has the potential to be employed to identify the characteristic frequencies of damaged conditions in railway tracks in the frequency range of 300-3000 Hz.

  15. Optical coherence tomography patterns as predictors of visual outcome in dengue-related maculopathy.

    PubMed

    Teoh, Stephen C; Chee, Caroline K; Laude, Augustinus; Goh, Kong Y; Barkham, Timothy; Ang, Brenda S

    2010-03-01

    The purpose of this study was to characterize the presentations, long-term outcomes, and visual prognostic factors in dengue-related maculopathy of 41 patients with dengue fever and impaired vision from dengue-related maculopathy in a retrospective noninterventional and observational series. The medical records of patients with dengue-related maculopathy diagnosed over 18 months between July 2004 and December 2005 at The Eye Institute, Tan Tock Seng Hospital and Communicable Disease Center, Singapore, were reviewed and followed up for 24 months. Visual acuity and symptoms (presence of scotoma on automated visual fields and Amsler grid) were correlated with optical coherence tomography evaluation. Mean age was 28.7 years and there were more men (53.7%). The most common visual complaints were blurring of vision (51.2%) and central scotoma (34.1%). Most patients recovered best-corrected visual acuity >20/40. Optical coherence tomography showed 3 patterns of maculopathy: 1) diffuse retinal thickening; 2) cystoid macular edema; and 3) foveolitis. The visual outcome was independent of the extent of edema, but scotomata persisted longest in patients with foveolitis and shortest with those with diffuse retinal thickening. Dengue-associated ocular inflammation is an emerging ophthalmic condition and often involves the posterior segment. Prognosis is variable. Patients usually regain good vision but may retain persistent scotomata even at 2 years despite clinical resolution of the disease. Optical coherence tomography patterns in dengue maculopathy are useful for characterization, monitoring, and prognostication of the visual defect.

  16. Cross-talk between topological defects in different fields revealed by nematic microfluidics

    PubMed Central

    Giomi, Luca; Kos, Žiga; Ravnik, Miha

    2017-01-01

    Topological defects are singularities in material fields that play a vital role across a range of systems: from cosmic microwave background polarization to superconductors and biological materials. Although topological defects and their mutual interactions have been extensively studied, little is known about the interplay between defects in different fields—especially when they coevolve—within the same physical system. Here, using nematic microfluidics, we study the cross-talk of topological defects in two different material fields—the velocity field and the molecular orientational field. Specifically, we generate hydrodynamic stagnation points of different topological charges at the center of star-shaped microfluidic junctions, which then interact with emergent topological defects in the orientational field of the nematic director. We combine experiments and analytical and numerical calculations to show that a hydrodynamic singularity of a given topological charge can nucleate a nematic defect of equal topological charge and corroborate this by creating −1, −2, and −3 topological defects in four-, six-, and eight-arm junctions. Our work is an attempt toward understanding materials that are governed by distinctly multifield topology, where disparate topology-carrying fields are coupled and concertedly determine the material properties and response. PMID:28674012

  17. Treatment of a Focal Articular Cartilage Defect of the Talus with Polymer-Based Autologous Chondrocyte Implantation: A 12-Year Follow-Up Period.

    PubMed

    Kreuz, Peter Cornelius; Kalkreuth, Richard Horst; Niemeyer, Philipp; Uhl, Markus; Erggelet, Christoph

    Autologous chondrocyte implantation (ACI) is a first-line treatment option for large articular cartilage defects. Although well-established for cartilage defects in the knee, studies of the long-term outcomes of matrix-assisted ACI to treat cartilage defects in the ankle are rare. In the present report, we describe for the first time the long-term clinical and radiologic results 12 years after polymer-based matrix-assisted ACI treat a full-thickness talar cartilage defect in a 25-year-old male patient. The clinical outcome was assessed using the visual analog scale and Freiburg ankle score, magnetic resonance imaging evaluation using the Henderson-Kreuz scoring system and T2 mapping. Clinical assessment revealed improved visual analog scale and Freiburg ankle scores. The radiologic analysis and T2 relaxation time values indicated the formation of hyaline-like repair tissue. Polymer-based autologous chondrocytes has been shown to be a safe and clinically effective long-term treatment of articular cartilage defects in the talus. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. [Comparison of initial and delayed myocardial imaging with beta-methyl-p-[123I]-iodophenylpentadecanoic acid in acute myocardial infarction].

    PubMed

    Naruse, H; Yoshimura, N; Yamamoto, J; Morita, M; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M

    1994-01-01

    Myocardial imaging using beta-methyl-p-[123I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess "fill-in" and "washout" defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed "fill-in" defects, and 24/180 segments (13%) showed "washout" defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with "fill-in" defects was 9.0 +/- 16.6%, and that of "washout" defects was 24.9 +/- 18.1% which was significantly higher than in controls (8.7 +/- 15.4%, p < 0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion.

  19. Driving with homonymous visual field loss: a review of the literature

    PubMed Central

    Bowers, Alex R.

    2016-01-01

    Driving is an important rehabilitation goal for patients with homonymous field defects (HFDs); however, whether or not people with HFDs should be permitted to drive is not clear. Over the last 15 years there has been a marked increase in the number of studies evaluating the effects of HFDs on driving performance. This review of the literature provides a much-needed summary for practitioners and researchers, addressing the following topics: regulations pertaining to driving with HFDs, self-reported driving difficulties, pass rates in on-road tests, the effects of HFDs on lane position and steering stability, the effects of HFDs on scanning and detection of potential hazards, screening for potential fitness to drive, evaluating practical fitness to drive, and the efficacy of interventions to improve driving of persons with HFDs. Although there is clear evidence from on-road studies that some people with HFDs may be rated as safe to drive, others are reported to have significant deficits in skills important for safe driving including taking a lane position too close to one side of the travel lane, unstable steering and inadequate viewing (scanning) behaviors. Driving simulator studies have provided strong evidence of a wide range in compensatory scanning abilities and detection performance, despite similar amounts of visual field loss. Conventional measurements of visual field extent (in which eye movements are not permitted) do not measure such compensatory abilities and are not predictive of on-road driving performance; thus, there is a need to develop better tests to screen for visual fitness to drive of people with HFDs. We are not yet at a point where we can predict which HFD patient is likely to be a safe driver. Therefore, it seems only fair to provide an opportunity for individualized assessments of practical fitness to drive either on the road and/or in a driving simulator. PMID:27535208

  20. Driving with homonymous visual field loss: a review of the literature.

    PubMed

    Bowers, Alex R

    2016-09-01

    Driving is an important rehabilitation goal for patients with homonymous field defects (HFDs); however, whether or not people with HFDs should be permitted to drive is not clear. Over the last 15 years, there has been a marked increase in the number of studies evaluating the effects of HFDs on driving performance. This review of the literature provides a much-needed summary for practitioners and researchers, addressing the following topics: regulations pertaining to driving with HFDs, self-reported driving difficulties, pass rates in on-road tests, the effects of HFDs on lane position and steering stability, the effects of HFDs on scanning and detection of potential hazards, screening for potential fitness to drive, evaluating practical fitness to drive and the efficacy of interventions to improve driving of persons with HFDs. Although there is clear evidence from on-road studies that some people with HFDs may be rated as safe to drive, others are reported to have significant deficits in skills important for safe driving, including taking a lane position too close to one side of the travel lane, unstable steering and inadequate viewing (scanning) behaviour. Driving simulator studies have provided strong evidence of a wide range in compensatory scanning abilities and detection performance, despite similar amounts of visual field loss. Conventional measurements of visual field extent (in which eye movements are not permitted) do not measure such compensatory abilities and are not predictive of on-road driving performance. Thus, there is a need to develop better tests to screen people with HFDs for visual fitness to drive. We are not yet at a point where we can predict which HFD patient is likely to be a safe driver. Therefore, it seems only fair to provide an opportunity for individualised assessments of practical fitness to drive either on the road and/or in a driving simulator. © 2016 Optometry Australia.

  1. [Long-term efficacy of laser peripheral iridotomy in preventing progression in eyes with pigment dispersion syndrome].

    PubMed

    Qing, Guoping; Zhang, Shaodan; Wang, Huaizhou; Wang, Tao; Wang, Shuhua; Chen, Hong; Wang, Hua; Wang, Ningli

    2014-07-01

    To evaluate the long-term efficacy of laser peripheral iridotomy (LPI) in preventing deterioration in eyes with pigment dispersion syndrome (PDS). A cohort study. Nineteen patients with PDS were treated with LPI and followed up periodically in Beijing Tongren Eye Center from May 2006 to April 2007. One eye of each patient was chosen randomly for the study. Main investigating items included iris configuration, intraocular pressure (IOP), anterior chamber pigmentation, and visual field analysis. The average follow-up period was (6.5 ± 0.3) years. A paired sample t test was used to determine whether there is a significant difference between average values of pre- and post-LPI IOP and mean deviation of Humphrey visual field analysis in these PDS eyes. The average age of the 19 patients were (35.8 ± 7.1) years on admission. The initial IOP of the 19 eyes was (24.7 ± 2.2) mmHg (1 mmHg = 0.133 kPa) before LPI. The mean deviation (MD) of Humphrey visual field analysis (VFA) were (-1.82 ± 1.26) dB (-4.34--0.28 dB) . All 19 eyes had concave iris and heavy trabecular pigmentation. The iris became flat in all PDS eyes after the laser treatment. At the last follow-up visit, the average IOP was 14.8 ± 2.0 (12-20) mmHg, which was statistically lower than that of baseline (t = 11.49, P < 0.01) . Extent of trabecular pigmentation reduced obviously in 16 eyes. No deterioration or new visual field defect was detected in any of the PDS eyes. MD of the last VFA was -1.79 ± 1.21 (-4.39--0.21 dB) . There was no statistical difference between MD of the last VFA and baseline (t = -0.26, P = 0.798). The long-term follow-up results showed that LPI prevents progression effectively in eyes with PDS.

  2. Momentum conserving defects in affine Toda field theories

    NASA Astrophysics Data System (ADS)

    Bristow, Rebecca; Bowcock, Peter

    2017-05-01

    Type II integrable defects with more than one degree of freedom at the defect are investigated. A condition on the form of the Lagrangian for such defects is found which ensures the existence of a conserved momentum in the presence of the defect. In addition it is shown that for any Lagrangian satisfying this condition, the defect equations of motion, when taken to hold everywhere, can be extended to give a Bäcklund transformation between the bulk theories on either side of the defect. This strongly suggests that such systems are integrable. Momentum conserving defects and Bäcklund transformations for affine Toda field theories based on the A n , B n , C n and D n series of Lie algebras are found. The defect associated with the D 4 affine Toda field theory is examined in more detail. In particular classical time delays for solitons passing through the defect are calculated.

  3. 76 FR 28308 - Compliance Policy Guide: Surgeons' Gloves and Patient Examination Gloves; Defects-Criteria for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... quality levels (AQLs) for leaks and visual defects observed during FDA testing of medical gloves. The CPG... practices regulation (21 CFR 10.115). The CPG represents FDA's current thinking on the criteria for direct...

  4. In-field implementation of impedance-based structural health monitoring for insulated rail joints

    NASA Astrophysics Data System (ADS)

    Albakri, Mohammad I.; Malladi, V. V. N. Sriram; Woolard, Americo G.; Tarazaga, Pablo A.

    2017-04-01

    Track defects are a major safety concern for the railroad industry. Among different track components, insulated rail joints, which are widely used for signaling purposes, are considered a weak link in the railroad track. Several joint-related defects have been identified by the railroad community, including rail wear, torque loss, and joint bar breakage. Current track inspection techniques rely on manual and visual inspection or on specially equipped testing carts, which are costly, timeconsuming, traffic disturbing, and prone to human error. To overcome the aforementioned limitations, the feasibility of utilizing impedance-based structural health monitoring for insulated rail joints is investigated in this work. For this purpose, an insulated joint, provided by Koppers Inc., is instrumented with piezoelectric transducers and assembled with 136 AREA rail plugs. The instrumented joint is then installed and tested at the Facility for Accelerated Service Testing, Transportation Technology Center Inc. The effects of environmental and operating conditions on the measured impedance signatures are investigated through a set of experiments conducted at different temperatures and loading conditions. The capabilities of impedance-based SHM to detect several joint-related damage types are also studied by introducing reversible mechanical defects to different joint components.

  5. Echocardiographic imaging techniques with subcostal and right parasternal longitudinal views in detecting sinus venosus atrial septal defects.

    PubMed

    McDonald, R W; Rice, M J; Reller, M D; Marcella, C P; Sahn, D J

    1996-01-01

    Sinus venosus atrial septal defects are frequently missed and difficult to visualize with conventional two-dimensional echocardiographic views. Using modified subcostal and right parasternal longitudinal views, nine patients were found to have a sinus venosus atrial septal defect. The modified subcostal view showed a sinus venosus atrial septal defect in all nine patients; three patients had secundum atrial septal defects as well. The right parasternal view detected only six patients with sinus venosus atrial septal defect. Partial anomalous pulmonary venous return was diagnosed in seven patients using these views. The combination of subcostal and right parasternal longitudinal imaging views will improve the detection of sinus venosus atrial septal defects.

  6. GPS Usage in a Population of Low-Vision Drivers.

    PubMed

    Cucuras, Maria; Chun, Robert; Lee, Patrick; Jay, Walter M; Pusateri, Gregg

    2017-01-01

    We surveyed bioptic and non-bioptic low-vision drivers in Illinois, USA, to determine their usage of global positioning system (GPS) devices. Low-vision patients completed an IRB-approved phone survey regarding driving demographics and usage of GPS while driving. Participants were required to be active drivers with an Illinois driver's license, and met one of the following criteria: best-corrected visual acuity (BCVA) less than or equal to 20/40, central or significant peripheral visual field defects, or a combination of both. Of 27 low-vision drivers, 10 (37%) used GPS while driving. The average age for GPS users was 54.3 and for non-users was 77.6. All 10 drivers who used GPS while driving reported increased comfort or safety level. Since non-GPS users were significantly older than GPS users, it is likely that older participants would benefit from GPS technology training from their low-vision eye care professionals.

  7. Visual functions of workers exposed to organic solvents in petrochemical industries

    PubMed Central

    Indhushree, R.; Monica, R.; Coral, K.; Angayarkanni, Narayanasamy; Punitham, R.; Subburathinam, B. M.; Krishnakumar, R.; Santanam, P. P.

    2016-01-01

    Aim: The purpose of this study was to evaluate the visual functions of workers exposed to organic solvents in petrochemical industries. Materials and Methods: Thirty workers from the petroleum refinery and 30 age-matched controls (mean age) were recruited. Visual functions and occupational exposure levels were assessed among both the groups. Visual acuity, contrast sensitivity, color vision, and visual fields were evaluated at the workplace. The biological samples, namely blood and urine, were collected at the workplace and transported to the laboratory for analysis. The urinary excretion of hippuric and methylhippuric acid as well as creatinine was measured by high performance liquid chromatography. Results: The mean age of the workers and controls were 39.7 ± 7.6 years and 38.6 ± 8.1, years respectively. The mean years of experience of the workers were 15.6 ± 6.8 years. Visual acuity was >0.01 LogMAR among both the control and case groups. The contrast sensitivity was reduced at 12cpd among workers. Comparison between groups was done using independent sample t-test. The mean difference in color confusion index was 0.11 ± 0.05 (P = 0.037*). The mean difference in visual fields was −0.31 ± 0.36 dB (P = 0.933). The mean difference in urinary hippuric acid level (urinary metabolite of toluene) between the groups was 0.19 ± 0.96 g/g creatinine (P = 0.049FNx01). The mean difference in the excretion of methylhippuric acid (urinary metabolite of xylene) was 0.06 ± 0.04g/g creatinine (P = 0.154). We also found that exposure was a significant risk factor for color vision defect with an odds ratio of 4.43 (95% CI: 1.36–14.4); P = 0.013. Conclusion: The study results showed that contrast sensitivity and color vision were affected among workers in petrochemical industry. PMID:28446838

  8. Identification and prioritization of rail squat defects in the field using rail magnetisation technology

    NASA Astrophysics Data System (ADS)

    Kaewunruen, Sakdirat

    2015-04-01

    Inevitably, rail squats and studs are continuing to be a serious problem for railway organisations around the world in the 21st century. They are typically classified as the growth of any cracks that have grown longitudinally through the subsurface and some of the cracks propagating to the bottom of rails transversely, and have branched from initial longitudinal cracks with a depression of rail surface. The horizontal crack, which results in a depression of rail surface, induces increased maintenance level, more frequent monitoring, compromised rail testing (as the crack shields the signal echoes), and possible broken rails. This paper presents field investigations using a magnetised-rail testing device developed by MRX Technologies to identify and prioritise the rail squats. Most of the in situ squats were found on the high rail of the transition (variable-radius curved track), which is associated with rolling contact fatigue (RCF). This investigation highlights the field performance of the MRX's surface crack detection technology in comparison with the traditional ultrasonic method and detailed walking inspection. Visually, it was found in the field that the size of the RCF squats varies from very small to moderate. The predicted crack data were obtained by scanning the magnitised rails. The comparison of the actual crack depths (ultrasonic) and the predicted crack depths (MRX device) shows: • A possible correlation for small RCF/ squat cracks. • Poor interpretation of larger defects and welds. The field assessment also suggests some practical issues required for further development, including the detection of rail spalling, deep transverse crack, welding, and so on.

  9. Direct observation of antisite defects in LiCoPO4 cathode materials by annular dark- and bright-field electron microscopy.

    PubMed

    Truong, Quang Duc; Devaraju, Murukanahally Kempaiah; Tomai, Takaaki; Honma, Itaru

    2013-10-23

    LiCoPO4 cathode materials have been synthesized by a sol-gel route. X-ray diffraction analysis confirmed that LiCoPO4 was well-crystallized in an orthorhombic structure in the Pmna space group. From the high-resolution transmission electron microscopy (HR-TEM) image, the lattice fringes of {001} and {100} are well-resolved. The HR-TEM image and selected area electron diffraction pattern reveal the highly crystalline nature of LiCoPO4 having an ordered olivine structure. The atom-by-atom structure of LiCoPO4 olivine has been observed, for the first time, using high-angle annular dark-field (HAADF) and annual bright-field scanning transmission electron microscopy. We observed the bright contrast in Li columns in the HAADF images and strong contrast in the ABF images, directly indicating the antisite exchange defects in which Co atoms partly occupy the Li sites. The LiCoPO4 cathode materials delivered an initial discharge capacity of 117 mAh/g at a C/10 rate with moderate cyclic performance. The discharge profile of LiCoPO4 shows a plateau at 4.75 V, revealing its importance as a potentially high-voltage cathode. The direct visualization of atom-by-atom structure in this work represents important information for the understanding of the structure of the active cathode materials for Li-ion batteries.

  10. Interaction of excitable waves emitted from two defects by pulsed electric fields

    NASA Astrophysics Data System (ADS)

    Chen, Jiang-Xing; Zhang, Han; Qiao, Li-Yan; Liang, Hong; Sun, Wei-Gang

    2018-01-01

    In response to a pulsed electric field, spatial distributed heterogeneities in excitable media can serve as nucleation sites for the generation of intramural electrical waves, a phenomenon called as ;wave emission from heterogeneities; (WEH effect). Heterogeneities in cardiac tissue strongly influence each other in the WEH effect. We study the WEH effect in a medium possessing two defects. The role of two defects and their interaction by pulsed DC electric fields (DEF) and rotating electric fields (REF) are investigated. The direction of the applied electric field plays a major role not only in the minimum electrical field necessary to originate wave propagation, but also in the degree of influences of nearby defects. The distance between two defects, i.e. the density of defects, also play an important role in the WEH effect. Generally, the REF is better than the DEF when pulsed electric fields are applied. These results may contribute to the improved application of WEH, especially in older patients with fibrosis and scarring, which are accompanied by a higher incidence of conductivity discontinuities.

  11. Photothermal coherence tomography for 3-D visualization and structural non-destructive imaging of a wood inlay

    NASA Astrophysics Data System (ADS)

    Tavakolian, Pantea; Sfarra, Stefano; Gargiulo, Gianfranco; Sivagurunathan, Koneshwaran; Mandelis, Andreas

    2018-06-01

    The aim of this research is to investigate the suitability of truncated correlation photothermal coherence tomography (TC-PCT) for the non-destructive imaging of a replica of a real inlay to identify subsurface features that often are invisible areas of vulnerability and damage. Defects of inlays involve glue-rich areas, glue-starved areas, termite attack, insect damage, and laminar splitting. These defects have the potential to result in extensive damage to the art design layers of inlays. Therefore, there is a need for an imaging technique to visualize and determine the location of defects within the sample. The recently introduced TC-PCT modality proved capable of providing 3-D images of specimens with high axial resolution, deep subsurface depth profiling capability, and high signal-to-noise ratio (SNR). Therefore, in this study the authors used TC-PCT to image a fabricated inlay sample with various natural and artificial defects in the middle and top layers. The inlay in question reproduces to scale a piece of art preserved in the "Mirror room" of the Castle Laffitte in France. It was built by a professional restorer following the ancient procedure named element by element. Planar TC-PCT images of the inlay were stacked coherently to provide 3-D visualization of areas with known defects in the sample. The experimental results demonstrated the identification of defects such as empty holes, a hole filled with stucco, subsurface delaminations and natural features such as a wood knot and wood grain in different layers of the sample. For this wooden sample that has a very low thermal diffusivity, a depth range of 2 mm was achieved.

  12. Sub-surface defects detection of by using active thermography and advanced image edge detection

    NASA Astrophysics Data System (ADS)

    Tse, Peter W.; Wang, Gaochao

    2017-05-01

    Active or pulsed thermography is a popular non-destructive testing (NDT) tool for inspecting the integrity and anomaly of industrial equipment. One of the recent research trends in using active thermography is to automate the process in detecting hidden defects. As of today, human effort has still been using to adjust the temperature intensity of the thermo camera in order to visually observe the difference in cooling rates caused by a normal target as compared to that by a sub-surface crack exists inside the target. To avoid the tedious human-visual inspection and minimize human induced error, this paper reports the design of an automatic method that is capable of detecting subsurface defects. The method used the technique of active thermography, edge detection in machine vision and smart algorithm. An infrared thermo-camera was used to capture a series of temporal pictures after slightly heating up the inspected target by flash lamps. Then the Canny edge detector was employed to automatically extract the defect related images from the captured pictures. The captured temporal pictures were preprocessed by a packet of Canny edge detector and then a smart algorithm was used to reconstruct the whole sequences of image signals. During the processes, noise and irrelevant backgrounds exist in the pictures were removed. Consequently, the contrast of the edges of defective areas had been highlighted. The designed automatic method was verified by real pipe specimens that contains sub-surface cracks. After applying such smart method, the edges of cracks can be revealed visually without the need of using manual adjustment on the setting of thermo-camera. With the help of this automatic method, the tedious process in manually adjusting the colour contract and the pixel intensity in order to reveal defects can be avoided.

  13. Normal-tension glaucoma (Low-tension glaucoma)

    PubMed Central

    Anderson, Douglas R

    2011-01-01

    Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP), with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG), defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like), or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective. PMID:21150042

  14. Entanglement entropy in integrable field theories with line defects II. Non-topological defect

    NASA Astrophysics Data System (ADS)

    Jiang, Yunfeng

    2017-08-01

    This is the second part of two papers where we study the effect of integrable line defects on bipartite entanglement entropy in integrable field theories. In this paper, we consider non-topological line defects in Ising field theory. We derive an infinite series expression for the entanglement entropy and show that both the UV and IR limits of the bulk entanglement entropy are modified by the line defect. In the UV limit, we give an infinite series expression for the coefficient in front of the logarithmic divergence and the exact defect g-function. By tuning the defect to be purely transmissive and reflective, we recover correctly the entanglement entropy of the bulk and with integrable boundary respectively.

  15. Hypodense regions (holes) in the retinal nerve fiber layer in frequency-domain OCT scans of glaucoma patients and suspects.

    PubMed

    Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2011-09-09

    To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.

  16. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    PubMed

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p < 0.001; veins: r = 0.685 p < 0.001). Vessel diameters showed a strong correlation with RNFLT and MD. This, as well as the reduction of stimulation-induced change in arterio-venous oxygen saturation difference with visual field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Fabric defect detection based on visual saliency using deep feature and low-rank recovery

    NASA Astrophysics Data System (ADS)

    Liu, Zhoufeng; Wang, Baorui; Li, Chunlei; Li, Bicao; Dong, Yan

    2018-04-01

    Fabric defect detection plays an important role in improving the quality of fabric product. In this paper, a novel fabric defect detection method based on visual saliency using deep feature and low-rank recovery was proposed. First, unsupervised training is carried out by the initial network parameters based on MNIST large datasets. The supervised fine-tuning of fabric image library based on Convolutional Neural Networks (CNNs) is implemented, and then more accurate deep neural network model is generated. Second, the fabric images are uniformly divided into the image block with the same size, then we extract their multi-layer deep features using the trained deep network. Thereafter, all the extracted features are concentrated into a feature matrix. Third, low-rank matrix recovery is adopted to divide the feature matrix into the low-rank matrix which indicates the background and the sparse matrix which indicates the salient defect. In the end, the iterative optimal threshold segmentation algorithm is utilized to segment the saliency maps generated by the sparse matrix to locate the fabric defect area. Experimental results demonstrate that the feature extracted by CNN is more suitable for characterizing the fabric texture than the traditional LBP, HOG and other hand-crafted features extraction method, and the proposed method can accurately detect the defect regions of various fabric defects, even for the image with complex texture.

  18. An intelligent system for real time automatic defect inspection on specular coated surfaces

    NASA Astrophysics Data System (ADS)

    Li, Jinhua; Parker, Johné M.; Hou, Zhen

    2005-07-01

    Product visual inspection is still performed manually or semi automatically in most industries from simple ceramic tile grading to complex automotive body panel paint defect and surface quality inspection. Moreover, specular surfaces present additional challenge to conventional vision systems due to specular reflections, which may mask the true location of objects and lead to incorrect measurements. There are some sophisticated visual inspection methods developed in recent years. Unfortunately, most of them are highly computational. Systems built on those methods are either inapplicable or very costly to achieve real time inspection. In this paper, we describe an integrated low-cost intelligent system developed to automatically capture, extract, and segment defects on specular surfaces with uniform color coatings. The system inspects and locates regular surface defects with lateral dimensions as small as a millimeter. The proposed system is implemented on a group of smart cameras using its on-board processing ability to achieve real time inspection. The experimental results on real test panels demonstrate the effectiveness and robustness of proposed system.

  19. Eye movements during visual search in patients with glaucoma

    PubMed Central

    2012-01-01

    Background Glaucoma has been shown to lead to disability in many daily tasks including visual search. This study aims to determine whether the saccadic eye movements of people with glaucoma differ from those of people with normal vision, and to investigate the association between eye movements and impaired visual search. Methods Forty patients (mean age: 67 [SD: 9] years) with a range of glaucomatous visual field (VF) defects in both eyes (mean best eye mean deviation [MD]: –5.9 (SD: 5.4) dB) and 40 age-related people with normal vision (mean age: 66 [SD: 10] years) were timed as they searched for a series of target objects in computer displayed photographs of real world scenes. Eye movements were simultaneously recorded using an eye tracker. Average number of saccades per second, average saccade amplitude and average search duration across trials were recorded. These response variables were compared with measurements of VF and contrast sensitivity. Results The average rate of saccades made by the patient group was significantly smaller than the number made by controls during the visual search task (P = 0.02; mean reduction of 5.6% (95% CI: 0.1 to 10.4%). There was no difference in average saccade amplitude between the patients and the controls (P = 0.09). Average number of saccades was weakly correlated with aspects of visual function, with patients with worse contrast sensitivity (PR logCS; Spearman’s rho: 0.42; P = 0.006) and more severe VF defects (best eye MD; Spearman’s rho: 0.34; P = 0.037) tending to make less eye movements during the task. Average detection time in the search task was associated with the average rate of saccades in the patient group (Spearman’s rho = −0.65; P < 0.001) but this was not apparent in the controls. Conclusions The average rate of saccades made during visual search by this group of patients was fewer than those made by people with normal vision of a similar average age. There was wide variability in saccade rate in the patients but there was an association between an increase in this measure and better performance in the search task. Assessment of eye movements in individuals with glaucoma might provide insight into the functional deficits of the disease. PMID:22937814

  20. Visual function among commercial vehicle drivers in the central region of Ghana

    PubMed Central

    Boadi-Kusi, Samuel Bert; Kyei, Samuel; Asare, Frederick Afum; Owusu-Ansah, Andrew; Awuah, Agnes; Darko-Takyi, Charles

    2015-01-01

    Aim To determine the relationship between some visual functions: colour vision defects, abnormal stereopsis, visual acuity and the occurrence of road traffic accident (RTAs) among commercial vehicle drivers in the central region of Ghana, and to assess their knowledge of these anomalies. Method A descriptive cross-sectional study employing a multi-stage random sampling approach was conducted in the major commercial towns within the central region of Ghana. Participants were taken through a comprehensive eye examination after the administration of a structured questionnaire. Results 520 male commercial vehicle drivers were enrolled for this study with a mean age of 39.23 years ±10.96 years and mean visual acuity of 0.02 ± 0.08 logMAR. Protans were more likely to be involved in RTAs (χ2 = 6.194, p = 0.034). However, there was no statistically significant association between abnormal stereopsis (OR = 0.89 95% CI: 0.44–1.80, p = 0.56), poor vision due to refractive error (χ2 = 3.090, p = 0.388) and the occurrence of RTAs. While 86.9% were aware of abnormal stereopsis, only 45% were aware of colour vision defects. There was a statistically significant association between stereopsis anomaly and colour vision defect (r = 0.371, p < 0.005). Conclusion The study found an association between protanopia and RTAs but none between stereopsis anomalies, refractive errors and the occurrence of RTAs. Drivers were less knowledgeable on colour vision defects as compared to stereopsis anomalies. PMID:26364760

  1. Visual function among commercial vehicle drivers in the central region of Ghana.

    PubMed

    Boadi-Kusi, Samuel Bert; Kyei, Samuel; Asare, Frederick Afum; Owusu-Ansah, Andrew; Awuah, Agnes; Darko-Takyi, Charles

    2016-01-01

    To determine the relationship between some visual functions: colour vision defects, abnormal stereopsis, visual acuity and the occurrence of road traffic accident (RTAs) among commercial vehicle drivers in the central region of Ghana, and to assess their knowledge of these anomalies. A descriptive cross-sectional study employing a multi-stage random sampling approach was conducted in the major commercial towns within the central region of Ghana. Participants were taken through a comprehensive eye examination after the administration of a structured questionnaire. 520 male commercial vehicle drivers were enrolled for this study with a mean age of 39.23 years ±10.96 years and mean visual acuity of 0.02±0.08 logMAR. Protans were more likely to be involved in RTAs (χ(2)=6.194, p=0.034). However, there was no statistically significant association between abnormal stereopsis (OR=0.89 95% CI: 0.44-1.80, p=0.56), poor vision due to refractive error (χ(2)=3.090, p=0.388) and the occurrence of RTAs. While 86.9% were aware of abnormal stereopsis, only 45% were aware of colour vision defects. There was a statistically significant association between stereopsis anomaly and colour vision defect (r=0.371, p<0.005). The study found an association between protanopia and RTAs but none between stereopsis anomalies, refractive errors and the occurrence of RTAs. Drivers were less knowledgeable on colour vision defects as compared to stereopsis anomalies. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  2. Penetration Depth and Defect Image Contrast Formation in Grazing-Incidence X-ray Topography of 4H-SiC Wafers

    NASA Astrophysics Data System (ADS)

    Yang, Yu; Guo, Jianqiu; Goue, Ouloide Yannick; Kim, Jun Gyu; Raghothamachar, Balaji; Dudley, Michael; Chung, Gill; Sanchez, Edward; Manning, Ian

    2018-02-01

    Synchrotron x-ray topography in grazing-incidence geometry is useful for discerning defects at different depths below the crystal surface, particularly for 4H-SiC epitaxial wafers. However, the penetration depths measured from x-ray topographs are much larger than theoretical values. To interpret this discrepancy, we have simulated the topographic contrast of dislocations based on two of the most basic contrast formation mechanisms, viz. orientation and kinematical contrast. Orientation contrast considers merely displacement fields associated with dislocations, while kinematical contrast considers also diffraction volume, defined as the effective misorientation around dislocations and the rocking curve width for given diffraction vector. Ray-tracing simulation was carried out to visualize dislocation contrast for both models, taking into account photoelectric absorption of the x-ray beam inside the crystal. The results show that orientation contrast plays the key role in determining both the contrast and x-ray penetration depth for different types of dislocation.

  3. [Visual rehabilitation of patients with large post-traumatic defects of the anterior eye segment through iris-lens diaphragm implantation].

    PubMed

    Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N

    The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.

  4. Development and Implementation of a New Telerehabilitation System for Audiovisual Stimulation Training in Hemianopia

    PubMed Central

    Tinelli, Francesca; Cioni, Giovanni; Purpura, Giulia

    2017-01-01

    Telerehabilitation, defined as the method by which communication technologies are used to provide remote rehabilitation, although still underused, could be as efficient and effective as the conventional clinical rehabilitation practices. In the literature, there are descriptions of the use of telerehabilitation in adult patients with various diseases, whereas it is seldom used in clinical practice with child and adolescent patients. We have developed a new audiovisual telerehabilitation (AVT) system, based on the multisensory capabilities of the human brain, to provide a new tool for adults and children with visual field defects in order to improve ocular movements toward the blind hemifield. The apparatus consists of a semicircular structure in which visual and acoustic stimuli are positioned. A camera is integrated into the mechanical structure in the center of the panel to control eye and head movements. Patients can use this training system with a customized software on a tablet. From hospital, the therapist has complete control over the training process, and the results of the training sessions are automatically available within a few minutes on the hospital website. In this paper, we report the AVT system protocol and the preliminary results on its use by three adult patients. All three showed improvements in visual detection abilities with long-term effects. In the future, we will test this apparatus with children and their families. Since interventions for impairments in the visual field have a substantial cost for individuals and for the welfare system, we expect that our research could have a profound socio-economic impact avoiding prolonged and intensive hospital stays. PMID:29209271

  5. 14 CFR 15.101 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PROCEDURAL RULES... (b) Aeronautical data that— (1) Is visually displayed in the cockpit of an aircraft; and (2) When visually displayed, accurately depicts a defective or deficient flight procedure or airway promulgated by...

  6. Study on the intrinsic defects in tin oxide with first-principles method

    NASA Astrophysics Data System (ADS)

    Sun, Yu; Liu, Tingyu; Chang, Qiuxiang; Ma, Changmin

    2018-04-01

    First-principles and thermodynamic methods are used to study the contribution of vibrational entropy to defect formation energy and the stability of the intrinsic point defects in SnO2 crystal. According to thermodynamic calculation results, the contribution of vibrational entropy to defect formation energy is significant and should not be neglected, especially at high temperatures. The calculated results indicate that the oxygen vacancy is the major point defect in undoped SnO2 crystal, which has a higher concentration than that of the other point defect. The property of negative-U is put forward in SnO2 crystal. In order to determine the most stable defects much clearer under different conditions, the most stable intrinsic defect as a function of Fermi level, oxygen partial pressure and temperature are described in the three-dimensional defect formation enthalpy diagrams. The diagram visually provides the most stable point defects under different conditions.

  7. Association between the Frequency of Optic Disk Hemorrhage and Progression of NTG Related with the Initial Location of RNFL Defect.

    PubMed

    Cho, Hyun-Kyung; Lee, Min Gyu; Kee, Changwon

    2018-06-12

    This study aimed to investigate the association of the frequency of optic disk hemorrhage (DH) and progression of normal tension glaucoma (NTG) between each group based on the location of the initial retinal nerve fiber layer (RNFL) defect. In this retrospective, observational cohort study, 142 NTG patients who underwent more than 5 reliable visual field tests with initial superior hemifield (group 2, n = 51), inferior hemifield (group 1, n = 44), or both hemifield (group 3, n = 47) defects were included. The number of DHs was inspected in serial optic disk photographs by 2 different ophthalmologists. Progression rates, which are the slope of mean thresholds from the 52 points, were calculated using a linear mixed effect model. The mean follow-up period was 8.19 ± 3.30 years. DHs related with the initial RNFL defect occurred significantly more frequently in group 2 (35 in inferior hemifield) than in group 1 (6 in superior hemifield) (p = 0.009) or group 3 (6 in inferior hemifield) (p = 0.006). The progression rate in group 2 was significantly faster than in group 1 (p = 0.019) or the superior hemifield of group 3 (p = 0.001). The progression rate of subjects showing recurrent DH was significantly faster than those showing single DH from all groups (-0.5460 vs. -0.2867 dB/year, p = 0.0053). More careful examination and caution are required when NTG patients show recurrent DH in the inferior hemifield related to the initial RNFL defect. © 2018 S. Karger AG, Basel.

  8. Visual function of drivers and its relationship to road traffic accidents in Urban Africa.

    PubMed

    Pepple, Godswill; Adio, Adedayo

    2014-01-01

    Nigeria has one of the highest mortality rates from Road traffic accidents (RTAs). Prevention is a global priority. This study is aimed at acquiring information for effective policy formulation to improve safety on Nigerian roads. This is a cross sectional descriptive study in which consenting commercial drivers in a Nigerian motor parks were ophthalmically examined after an interview. Data analyzed with EPI-INFO version 6.0 statistical software using Chi square. P value < 0.05 was considered to be significant. The eyes of 400 commercial drivers were examined. Ages range from 25 to 62 years with mean of 37.8 years (SD ± 9.1) 20% did not undergo any prior driving test and only one third of those who had (n = 120, 30.9%) had a prior eye test. Up to 45.5% (n = 182) had been involved in RTAs with alcohol intoxication and driver fatigue significantly associated. Depressants such as alcohol are commonly used. Visual impairment ((p = 0.46, χ (2) = 0.3, RR = 0.62), visual field defects (p > 0.05, χ(2) = 0.78, RR = 1.25) and color vision defects (p = 0.4, χ (2) = 0.77, RR = 1.23) were not significantly associated with occurrence of RTAs. However fatigue was found to be a predisposing factor in 28% of those who had RTAs. One out of every two commercial driver has been involved in an RTA in the past in Nigeria. Fatigue while driving should be avoided. Use of depressants while driving should be penalized. Blood alcohol content (BAC) levels should routinely be measured by road safety personnel in Nigeria. Periodic eye exams should be carried out for all commercial drivers before issuing or renewing licenses to drive and treatment for any ophthalmic conditions discovered enforced.

  9. Sensor Spatial Distortion, Visual Latency, and Update Rate Effects on 3D Tracking in Virtual Environments

    NASA Technical Reports Server (NTRS)

    Ellis, S. R.; Adelstein, B. D.; Baumeler, S.; Jense, G. J.; Jacoby, R. H.; Trejo, Leonard (Technical Monitor)

    1998-01-01

    Several common defects that we have sought to minimize in immersing virtual environments are: static sensor spatial distortion, visual latency, and low update rates. Human performance within our environments during large amplitude 3D tracking was assessed by objective and subjective methods in the presence and absence of these defects. Results show that 1) removal of our relatively small spatial sensor distortion had minor effects on the tracking activity, 2) an Adapted Cooper-Harper controllability scale proved the most sensitive subjective indicator of the degradation of dynamic fidelity caused by increasing latency and decreasing frame rates, and 3) performance, as measured by normalized RMS tracking error or subjective impressions, was more markedly influenced by changing visual latency than by update rate.

  10. Predictive value of spectral-domain optical coherence tomography features in assessment of visual prognosis in eyes with acute welding arc maculopathy.

    PubMed

    Zhang, Chunxia; Dang, Guangfu; Zhao, Tianmei; Wang, DongLin; Su, Yan; Qu, Yi

    2018-04-12

    To observe spectral-domain optical coherence tomography (SD-OCT) features and to determine whether baseline OCT features can be used as predictors of visual acuity outcome in eyes with acute welding arc maculopathy. This retrospective study enrolled twenty-two eyes of eleven subjects with acute welding arc maculopathy. All subjects were evaluated by SD-OCT at baseline and final visit. The involved parameters included best-corrected visual acuity (BCVA), central macular thickness (CMT), the length of ellipsoid zone (EZ) defects, the greatest linear dimension (GLD) of outer retinal lesions, EZ reflectivity and relative EZ reflectivity (defined as the ratio of EZ reflectivity to retinal pigment epithelium reflectivity on OCT). Acute welding arc maculopathy was presented as abnormal hyperreflectivity, hyporeflectivity and defects of outer retinal layer in fovea on OCT. Compared with baseline, BCVA improved significantly accompanied by decreased GLD of outer retinal lesions and the length of EZ defects at final visit (P = 0.0004, P < 0.0001 and P < 0.0001, respectively). No significant changes were shown on CMT (P = 0.248). In multivariate regression analysis, final BCVA was associated with baseline BCVA and the length of EZ defects (P = 0.012 and P = 0.045, respectively). However, EZ reflectivity and relative EZ reflectivity were not associated with final BCVA (P > 0.05). In conclusion, SD-OCT images clearly reveal morphological changes in outer retinal layer in acute welding arc maculopathy. The baseline BCVA and length of EZ defects are the strongest predictors of final BCVA.

  11. New Method of Screening Young Children for Defects in Visual Acuity*

    PubMed Central

    Withnell, Allan; Wilson, H. E.

    1968-01-01

    The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed. PMID:5681052

  12. New method of screening young children for defects in visual acuity.

    PubMed

    Withnell, A; Wilson, H E

    1968-10-19

    The methods used at present for screening young children's vision have disadvantages, such as that the child's intelligence can affect the result. In a new method three white cards are used; these are printed with one, two, or three black blocks arranged so that if a child can correctly state the number of blocks at 6 metres the visual acuity is at least 6/9. When tested on 186 children the new method gave better results than conventional tests; eight children with defective vision were picked up only by the new method and none were missed.

  13. Nerve Fiber Layer Thickness and Characteristics Associated with Glaucoma in Community Living Older Adults: Prelude to a Screening Trial?

    PubMed

    Klein, Barbara E K; Johnson, Chris A; Meuer, Stacy M; Lee, Kyungmoo; Wahle, Andreas; Lee, Kristine E; Kulkarni, Amruta; Sonka, Milan; Abràmoff, Michael D; Klein, Ronald

    2017-04-01

    To examine the associations of nerve fiber layer (NFL) thickness with other ocular characteristics in older adults. Participants in the Beaver Dam Eye Study (2008-2010) underwent spectral domain optical coherence tomography (SD-OCT) scans of the optic nerve head, imaging of optic discs, frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP), and an interview concerning their history of glaucoma and use of drops to lower eye pressure. Self-reported histories of glaucoma and the use of drops to lower eye pressure were obtained at follow-up examinations (2014-2016). NFL thickness measured on OCTs varied by location around the optic nerve. Age was associated with mean NFL thickness. Mean NFL was thinnest in eyes with larger cup/disc (C/D) ratios. Horizontal hemifield defects or other optic nerve-field defects were associated with thinner NFL. NFL in persons who reported taking eye drops for high intraocular pressure was thinner compared to those not taking drops. After accounting for the presence of high intraocular pressure, large C/D ratios or hemifield defects, eyes with thinner NFL in the arcades were more likely (OR = 2.3 for 30 micron thinner NFL, p = 0.04) to have incident glaucoma at examination 5 years later. Retinal NFL thickness was associated with a new history of self-reported glaucoma 5 years later. A trial testing the usefulness of NFL as part of a screening battery for predicting glaucoma in those previously undiagnosed might lead to improved case finding and, ultimately, to diminishing the risk of visual field loss.

  14. Prevalence of Split Nerve Fiber Layer Bundles in Healthy People Imaged with Spectral Domain Optical Coherence Tomography.

    PubMed

    Gür Güngör, Sirel; Akman, Ahmet; Sarıgül Sezenöz, Almila; Tanrıaşıkı, Gülşah

    2016-12-01

    The presence of retinal nerve fiber layer (RNFL) split bundles was recently described in normal eyes scanned using scanning laser polarimetry and by histologic studies. Split bundles may resemble RNFL loss in healthy eyes. The aim of our study was to determine the prevalence of nerve fiber layer split bundles in healthy people. We imaged 718 eyes of 359 healthy persons with the spectral domain optical coherence tomography in this cross-sectional study. All eyes had intraocular pressure of 21 mmHg or less, normal appearance of the optic nerve head, and normal visual fields (Humphrey Field Analyzer 24-2 full threshold program). In our study, a bundle was defined as 'split' when there is localized defect not resembling a wedge defect in the RNFL deviation map with a symmetrically divided RNFL appearance on the RNFL thickness map. The classification was performed by two independent observers who used an identical set of reference examples to standardize the classification. Inter-observer consensus was reached in all cases. Bilateral superior split bundles were seen in 19 cases (5.29%) and unilateral superior split was observed in 15 cases (4.16%). In 325 cases (90.52%) there was no split bundle. Split nerve fiber layer bundles, in contrast to single nerve fiber layer bundles, are not common findings in healthy eyes. In eyes with normal optic disc appearance, especially when a superior RNFL defect is observed in RNFL deviation map, the RNLF thickness map and graphs should also be examined for split nerve fiber layer bundles.

  15. Noninvasive 3D Visualization of Defects and Crack Propagation in Layered Foam Structures by Phase Contrast Microimaging

    NASA Technical Reports Server (NTRS)

    Hu, Z. W.; DeCarlo, F.

    2006-01-01

    Applications of polymeric foams in our modern society continue to grow because of their light weight, high strength, excellent thermal and mechanical insulation, and the ease of engineering. Among others, closed-cell foam has been structurally used for thermally insulating the shuttle external tank. However, internal defects of the foams were difficult to observe non-invasively due to limited sensitivity to the low-density structures possessed by traditional imaging tools such as computed X-ray tomography By combining phase contrast X-ray imaging with pressure loading, we succeeded in precisely mapping intact cellular structure and defects inside the bulk of layered foam and visualizing its subsequent response to the pressure in three-dimensional space. The work demonstrated a powerfir1 approach for yielding insight into underlying problems in lightweight cellular materials otherwise unobtainable.

  16. Defect imaging for plate-like structures using diffuse field.

    PubMed

    Hayashi, Takahiro

    2018-04-01

    Defect imaging utilizing a scanning laser source (SLS) technique produces images of defects in a plate-like structure, as well as spurious images occurring because of resonances and reverberations within the specimen. This study developed defect imaging by the SLS using diffuse field concepts to reduce the intensity of spurious images, by which the energy of flexural waves excited by laser can be estimated. The experimental results in the different frequency bandwidths of excitation waves and in specimens with different attenuation proved that clearer images of defects are obtained in broadband excitation using a chirp wave and in specimens with low attenuation, which produce diffuse fields easily.

  17. Special tinted contact lens on colour-defects.

    PubMed

    Mutilab, H A; Sharanjeet-Kaur; Keu, L K; Choo, P F

    2012-01-01

    The objective of this study was to determine the visual function of colour-deficient subjects when wearing special red tint contact lenses. A total of 17 subjects with congenital colour vision deficiency (14 deutans and 3 protans), voluntarily participated in this study. The average age for the subjects was 23.00 ± 4.06 years old. Visual functions tested were visual acuity (LogMAR), contrast sensitivity (FACT Chart) and stereopsis (TNO and Howard Dolman tests). Two types of special red tint lenses were used in this study; Type I (light red) and Type II (dark red). The protans and deutans showed no significant changes in visual acuity and contrast sensitivity when wearing either type of contact lens. Stereopsis testing using the Horward-Dolman test gave no significant changes but significant differences were seen using the TNO test. Stereopsis using the TNO test was significantly poorer with the red tinted contact lenses compared to without for both protons and deutans. Testing binocularly with Ishihara plates showed that 88% (n=15) of patients passed the test with Type I and Type II contact lenses. When D15 test was done, 3 patients (17.6%) were 'normal' when using the Type I contact lenses and 2 patients (11.8%) were 'normal' when using the Type II contact lenses. However, with FM100Hue test, most patients showed deutan responses. Total error scores (TES) were found to be higher with Type I and Type II contact lenses compared to without. The Type I and II special tinted contact lens used in this study did not cause a reduction of visual acuity and contrast sensitivity for the colour defects. Stereopsis was also not reduced with the Type I and Type II contact lenses for the colour defects except when tested with the TNO test. Colour vision defects became difficult to detect using the Ishihara plates but FM100Hue test did not show any improvement with the Type I and Type II contact lenses.

  18. Localised surface plasmon-like resonance generated by microwave electromagnetic waves in pipe defects

    NASA Astrophysics Data System (ADS)

    Alobaidi, Wissam M.; Nima, Zeid A.; Sandgren, Eric

    2018-01-01

    Localised surface plasmon (LSP)-like resonance phenomena were simulated in COMSOL Multiphysics™, and the electric field enhancement was evaluated in eight pipe defects using the microwave band from 1.80 to 3.00 GHz and analysed by finite element analysis (FEA). The simulation was carried out, in each defect case, on a pipe that has 762 mm length and 152.4 mm inner diameter, and 12.7 mm pipe wall thickness. Defects were positioned in the middle of the pipe and were named as follows; SD: Square Defect, FCD: fillet corner defect, FD: fillet defect, HCD: half circle defect, TCD: triangle corner defect, TD: triangle defect, ZD: zigzag defect, GD: gear defect. The LSP electric field, and scattering parametric (S21, and S11) waves were evaluated in all cases and found to be strongly dependent on the size and the shape of the defect rather than the pipe and or the medium materials.

  19. Real-time distortion correction for visual inspection systems based on FPGA

    NASA Astrophysics Data System (ADS)

    Liang, Danhua; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin

    2008-03-01

    Visual inspection is a kind of new technology based on the research of computer vision, which focuses on the measurement of the object's geometry and location. It can be widely used in online measurement, and other real-time measurement process. Because of the defects of the traditional visual inspection, a new visual detection mode -all-digital intelligent acquisition and transmission is presented. The image processing, including filtering, image compression, binarization, edge detection and distortion correction, can be completed in the programmable devices -FPGA. As the wide-field angle lens is adopted in the system, the output images have serious distortion. Limited by the calculating speed of computer, software can only correct the distortion of static images but not the distortion of dynamic images. To reach the real-time need, we design a distortion correction system based on FPGA. The method of hardware distortion correction is that the spatial correction data are calculated first under software circumstance, then converted into the address of hardware storage and stored in the hardware look-up table, through which data can be read out to correct gray level. The major benefit using FPGA is that the same circuit can be used for other circularly symmetric wide-angle lenses without being modified.

  20. The effect of a defective BSF layer on solar cell open circuit voltage. [Back Surface Field

    NASA Technical Reports Server (NTRS)

    Weizer, V. G.

    1985-01-01

    A straightforward analysis of special limiting cases has permitted the determination of the range of possible open circuit voltage losses due to a defective BSF (back surface field) layer. An important result of the analysis is the finding that it is possible to have a fully effective BSF region, regardless of the spatial distribution of the defective areas, as long as the total defective area is reduced below certain limits. Distributed defects were found to be much more harmful than lumped defects.

  1. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    PubMed

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  2. Correlation between postoperative area of high autofluorescence in macula and visual acuity after macular hole closure.

    PubMed

    Zhang, Peng; Shang, Qingli; Ma, Jingxue; Hao, Yuhua; Ye, Cunxi

    2017-03-20

    To determine the correlation between the preoperative basal diameter of macular hole, the postoperative area of high autofluorescence (AF) in macula, and visual acuity in full-thickness macular hole. Forty-nine patients with full-thickness macular hole who underwent vitrectomy and C3F8 filling were reviewed. The preoperative diameter of macular hole, the 6 months postoperative area of high AF in macula if it existed, the length of inner segment/outer segment (IS/OS) defect, and visual acuity were obtained. The correlation between them was determined. At postoperative 6 months, the rate of high AF in macula was 63.3%. There were statistical differences between with and without high AF groups in postoperative best-corrected visual acuity (BCVA) (t = -2.751, p = 0.008), preoperative basal diameter of macular hole (t = -4.946, p = 0.00001), and postoperative length of IS/OS defect (t = -8.351, p<0.00001). Simple linear regression analysis showed high positive correlations between preoperative basal diameter of macular hole and area of high AF (p<0.00001, r = 0.893), postoperative length of IS/OS defect and area of high fundus AF (FAF) (p<0.00001, r = 0.779), and negative correlations between area of high AF and postoperative BCVA (p = 0.037, r = 0.375). There was low correlation between diameter of macular hole and postoperative BCVA (p = 0.112). The preoperative basal diameter of macular hole and postoperative length of IS/OS defect decides the postoperative area of high AF in macula to some degree, and the postoperative area of high AF in macula can be an evaluating indicator for poor macular function recovery.

  3. Integrability of generalised type II defects in affine Toda field theory

    NASA Astrophysics Data System (ADS)

    Bristow, Rebecca

    2017-11-01

    The Liouville integrability of the generalised type II defects is investigated. Full integrability is not considered, only the existence of an infinite number of conserved quantities associated with a system containing a defect. For defects in affine Toda field theories (ATFTs) it is shown that momentum conservation is very likely to be a necessary condition for integrability. The defect Lax matrices which guarantee zero curvature, and so an infinite number of conserved quantities, are calculated for the momentum conserving Tzitzéica defect and the momentum conserving D 4 ATFT defect. Some additional calculations pertaining to the D 4 defect are also carried out to find a more complete set of defect potentials than has appeared previously.

  4. Visual and neurologic sequelae of methanol poisoning in Saudi Arabia

    PubMed Central

    Galvez-Ruiz, Alberto; Elkhamary, Sahar M.; Asghar, Nasira; Bosley, Thomas M.

    2015-01-01

    Objectives: To present the visual sequelae of methanol poisoning and to emphasize the characteristics of methanol exposure in the Kingdom of Saudi Arabia (KSA). Methods: A retrospective case series was carried out on 50 sequential patients with methanol poisoning seen at the King Khaled Eye Specialist Hospital and King Saud University Hospitals in Riyadh, KSA between 2008 and 2014. All patients were examined by a neuro-ophthalmologist at least one month after methanol intoxication. Results: All 50 patients were young or middle-aged males. All admitted to drinking unbranded alcohol within 2-3 days before profound or relatively profound, painless, bilateral visual loss. Mean visual acuity in this group was hand motions (logMAR 2.82; range 0.1 - 5.0) with some eye to eye variability within individuals. Worse visual acuity was correlated with advancing age (Pearson correlation: oculus dextrus [right eye] - 0.37, p=0.008; oculus sinister [left eye] - 0.36, p=0.011). All patients had optic atrophy bilaterally, and all tested patients had visual field defects. Tremors with or without rigidity were present in 12 patients, and 11 of 30 patients who had neuroimaging performed had evidence of putaminal necrosis. Conclusion: Methanol intoxication causes visual loss within 12-48 hours due to relatively severe, painless, bilateral optic nerve damage that may be somewhat variable between eyes, and is generally worse with advancing age. The coincidence of bilateral optic nerve damage and bilateral putaminal necrosis in a young or middle-aged male is very suspicious for methanol-induced damage. PMID:25935177

  5. Subsurface defect detection in first layer of pavement structure and reinforced civil engineering structure by FRP bonding using active infrared thermography

    NASA Astrophysics Data System (ADS)

    Dumoulin, Jean; Ibos, Laurent

    2010-05-01

    In many countries road network ages while road traffic and maintenance costs increase. Nowadays, thousand and thousand kilometers of roads are each year submitted to surface distress survey. They generally lean on pavement surface imaging measurement techniques, mainly in the visible spectrum, coupled with visual inspection or image processing detection of emergent distresses. Nevertheless, optimisation of maintenance works and costs requires an early detection of defects within the pavement structure when they still are hidden from surface. Accordingly, alternative measurement techniques for pavement monitoring are currently under investigation (seismic methods, step frequency radar). On the other hand, strengthening or retrofitting of reinforced concrete structures by externally bonded Fiber Reinforced Polymer (FRP) systems is now a commonly accepted and widespread technique. However, the use of bonding techniques always implies following rigorous installing procedures. To ensure the durability and long-term performance of the FRP reinforcements, conformance checking through an in situ auscultation of the bonded FRP systems is then highly suitable. The quality-control program should involve a set of adequate inspections and tests. Visual inspection and acoustic sounding (hammer tap) are commonly used to detect delaminations (disbonds) but are unable to provide sufficient information about the depth (in case of multilayered composite) and width of debonded areas. Consequently, rapid and efficient inspection methods are also required. Among the non destructive methods under study, active infrared thermography was investigated both for pavement and civil engineering structures through experiments in laboratory and numerical simulations, because of its ability to be also used on field. Pulse Thermography (PT), Pulse Phase Thermography (PPT) and Principal Component Thermography (PCT) approaches have been tested onto pavement samples and CFRP bonding on concrete samples in laboratory. In parallel numerical simulations have been used to generate a set of time sequence of thermal maps for simulated samples with and without subsurface defect. Using this set of experimental and simulated data different approaches (thermal contrast, FFT analysis, polynomial interpolation, singular value decomposition…) for defect location have been studied and compared. Defect depth retrieval was also studied on such data using different thermal model coupled to a direct or an inverse approach. Trials were conducted both with an uncooled and cooled infrared camera with different measurement performances. Results obtained will be discussed and analysed in the paper we plan to present. Finally, combining numerical simulations and experiments allows us discussing on the sensitivity influence of the infrared camera used to detect subsurface defects.

  6. Control of surface thermal scratch of strip in tandem cold rolling

    NASA Astrophysics Data System (ADS)

    Chen, Jinshan; Li, Changsheng

    2014-07-01

    The thermal scratch seriously affects the surface quality of the cold rolled stainless steel strip. Some researchers have carried out qualitative and theoretical studies in this field. However, there is currently a lack of research on effective forecast and control of thermal scratch defects in practical production, especially in tandem cold rolling. In order to establish precise mathematical model of oil film thickness in deformation zone, the lubrication in cold rolling process of SUS410L stainless steel strip is studied, and major factors affecting oil film thickness are also analyzed. According to the principle of statistics, mathematical model of critical oil film thickness in deformation zone for thermal scratch is built, with fitting and regression analytical method, and then based on temperature comparison method, the criterion for deciding thermal scratch defects is put forward. Storing and calling data through SQL Server 2010, a software on thermal scratch defects control is developed through Microsoft Visual Studio 2008 by MFC technique for stainless steel in tandem cold rolling, and then it is put into practical production. Statistics indicate that the hit rate of thermal scratch is as high as 92.38%, and the occurrence rate of thermal scratch is decreased by 89.13%. Owing to the application of the software, the rolling speed is increased by approximately 9.3%. The software developed provides an effective solution to the problem of thermal scratch defects in tandem cold rolling, and helps to promote products surface quality of stainless steel strips in practical production.

  7. Airborne ultrasonic inspection of hides and leather

    USDA-ARS?s Scientific Manuscript database

    Currently, hides and leather are visually inspected and ranked for quality, sale price and usable area. Visual inspection is not reliable for detecting defects, which are usually hidden inside the material. This manual assessment is non-uniform among operators, and often leads to disputes over fai...

  8. Evaluation of hides and leather using ultrasonic technology

    USDA-ARS?s Scientific Manuscript database

    Hides are visually inspected and ranked for quality and sale price. Because visual inspection is not reliable for detecting defects when hair is present, hides cannot be effectively sorted at the earliest stage of processing. Furthermore, this subjective assessment is non-uniform among operators, ...

  9. Noninvasive multi–photon fluorescence microscopy resolves retinol and retinal–condensation products in mouse eyes

    PubMed Central

    Palczewska, Grazyna; Maeda, Tadao; Imanishi, Yoshikazu; Sun, Wenyu; Chen, Yu; Williams, David R.; Piston, David; Maeda, Akiko; Palczewski, Krzysztof

    2010-01-01

    Multi–photon excitation fluorescence microscopy (MPM) can image certain molecular processes in vivo. In the eye, fluorescent retinyl esters in sub–cellular structures called retinosomes mediate regeneration of the visual chromophore, 11–cis–retinal, by the visual cycle. But harmful fluorescent condensation products were also identified previously. We report that in wild type mice, excitation with λ ~730 nm identified retinosomes in the retinal pigment epithelium, whereas excitation with λ ~910 nm revealed at least one additional retinal fluorophore. The latter fluorescence was absent in eyes of genetically modified mice lacking a functional visual cycle, but accentuated in eyes of older WT mice and mice with defective clearance of all–trans–retinal, an intermediate in the visual cycle. MPM, a noninvasive imaging modality that facilitates concurrent monitoring of retinosomes along with potentially harmful products in aging eyes, has the potential to detect early molecular changes due to age–related macular degeneration and other defects in retinoid metabolism. PMID:21076393

  10. [Surgical treatment with an artificial iris].

    PubMed

    Mayer, C S; Hoffmann, A E

    2015-10-01

    Iris defects with their disturbed pupillary function, visual impairment and glare constitute a therapeutic challenge in surgical reconstruction. A new therapeutic option for distinctive defects consists in the implantation of a custom-made silicone iris. This new and challenging therapy provides the opportunity to achieve an individual, aesthetically appealing and good functional result for the patient.

  11. Rubber hose surface defect detection system based on machine vision

    NASA Astrophysics Data System (ADS)

    Meng, Fanwu; Ren, Jingrui; Wang, Qi; Zhang, Teng

    2018-01-01

    As an important part of connecting engine, air filter, engine, cooling system and automobile air-conditioning system, automotive hose is widely used in automobile. Therefore, the determination of the surface quality of the hose is particularly important. This research is based on machine vision technology, using HALCON algorithm for the processing of the hose image, and identifying the surface defects of the hose. In order to improve the detection accuracy of visual system, this paper proposes a method to classify the defects to reduce misjudegment. The experimental results show that the method can detect surface defects accurately.

  12. Three-dimensional textures and defects of soft material layering revealed by thermal sublimation.

    PubMed

    Yoon, Dong Ki; Kim, Yun Ho; Kim, Dae Seok; Oh, Seong Dae; Smalyukh, Ivan I; Clark, Noel A; Jung, Hee-Tae

    2013-11-26

    Layering is found and exploited in a variety of soft material systems, ranging from complex macromolecular self-assemblies to block copolymer and small-molecule liquid crystals. Because the control of layer structure is required for applications and characterization, and because defects reveal key features of the symmetries of layered phases, a variety of techniques have been developed for the study of soft-layer structure and defects, including X-ray diffraction and visualization using optical transmission and fluorescence confocal polarizing microscopy, atomic force microscopy, and SEM and transmission electron microscopy, including freeze-fracture transmission electron microscopy. Here, it is shown that thermal sublimation can be usefully combined with such techniques to enable visualization of the 3D structure of soft materials. Sequential sublimation removes material in a stepwise fashion, leaving a remnant layer structure largely unchanged and viewable using SEM, as demonstrated here using a lamellar smectic liquid crystal.

  13. Development of a Pediatric Visual Field Test

    PubMed Central

    Miranda, Marco A.; Henson, David B.; Fenerty, Cecilia; Biswas, Susmito; Aslam, Tariq

    2016-01-01

    Purpose We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. Methods The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients' experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4–16 years old) with no history of VF defects were recruited. Results For the 14 subjects completing the study, 31 ± 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 ± 0.3 cd/m2 and 27.9 ± 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher – 8.3 ± 9.0 dB. Conclusions Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Translational Relevance Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population. PMID:27980876

  14. Familial Pallister-Hall in adulthood.

    PubMed

    Talsania, Mitali; Sharma, Rohan; Sughrue, Michael E; Scofield, R Hal; Lim, Jonea

    2017-10-01

    Pallister Hall syndrome is autosomal dominant disorder usually diagnosed in infants and children. Current diagnostic criteria include presence of hypothalamic hamartoma, post axial polydactyly and positive family history, but the disease has variable manifestations. Herein we report Pallister Hall syndrome diagnosed in a family where both patients were adults. A 59 year old man developed seizures 4 years prior to our evaluation of him, at which time imaging showed a hypothalamic hamartoma. The seizures were controlled medically. He did well until he had visual changes after a traumatic head injury. Repeat MRI showed slight expansion of the mass with formal visual field testing demonstrating bitemporal hemianopsia. There was no evidence of pituitary dysfunction except for large urine volume. He underwent surgery to debulk the hamartoma and the visual field defects improved. There was no hypopituitarism post-operatively, and the polydyspia resolved. His 29 year old daughter also had seizures and hypothalamic hamartoma. Both patients had had polydactyly with prior surgical correction in childhood. The daughter underwent genetic testing, which revealed a previously undescribed heterozygous single base pair deletion in exon 13 of the GLI3 gene causing a frameshift mutation. Further investigation into family history revealed multiple members in previous generations with polydactyly and/or seizures. Pallister-Hall syndrome is caused by an inherited autosomal dominant or de novo mutation in GLI3 gene. This rare syndrome has not had prevalence defined, however. Generally, diagnoses are made in the pediatric population. Our report adds to the few cases detected in adulthood.

  15. [Analysis of clinical phenotype and mode of inheritance in retinitis pigmentosa patients with consanguineous marriage].

    PubMed

    Rong, Wei-ning; Sheng, Xun-lun; Liu, Ya-ni

    2012-10-01

    To analyse the mode of inheritance and clinical characteristics of retinitis pigmentosa (RP) patients with consanguineous marriage. RP patients were recruited for this study in Ningxia Eye Hospital from September 2009 to July 2011. All patients received complete ophthalmic examination. The mode of inheritance were determined based on family history and marriage history. Clinical features were characterized by complete ophthalmic examinations including visual acuity, macular OCT, visual field and electroretinogram (ERG). A total of 143 individuals with RP (33 families) were recruited. Based on analysis of family history and marriage history, 20 RP families (23 patients) had consanguineous marriage history accounted for 60.6% RP families (16.1% RP patients). There were 4 patients (from 4 families) diagnosed as Usher syndrome. In 20 RP families with consanguineous marriage history, 7 families (35.0%) were Hui ethnicity and 13 families (65%) were Han ethnicity. The marriages of 15 families were between first cousins and 3 families were between second cousins, only 2 families were between half cousins matrimony. Of 23 RP patients, 12 were males and 11 were females. The average age of onset was 11.4 ± 6.8 years and the average age of recruitment was (32.0 ± 13.5) years. The best-corrected visual acuity was less than 0.6 in 78.2% patients. According to the features of the fundus, 13 patients were classical retinitis pigmentosa and 10 patients were retinitis pigmentosa sine pigmento. Visual field examination showed that all patients had varying degrees of peripheral visual field defect. Retinal neuroepithelial layer of macular and peripheral retina became thinner and retinal photoreceptors were disappeared. The average thickness of macular fovea was (186.1 ± 78.7) µm on right eyes and (187.4 ± 76.3) µm on left eyes. The incidence of RP with consanguineous marriages was high in Ningxia Region. The mode of inheritance of RP patients with consanguinity is autosomal recessive. The common marriage pattern of consanguinity is between first cousins. The age of onset is early and the ocular fundus changes of some patients are atypical, this should be paid attention clinically.

  16. Progression of lamellar hole-associated epiretinal proliferation and retinal changes during long-term follow-up.

    PubMed

    Compera, Denise; Schumann, Ricarda G; Cereda, Matteo G; Acquistapace, Alessandra; Lita, Viviane; Priglinger, Siegfried G; Staurenghi, Giovanni; Bottoni, Ferdinando

    2018-01-01

    To report on progression of lamellar hole-associated epiretinal proliferation (LHEP) in eyes with lamellar macular holes (LMH) using spectral-domain optical coherence tomography (SD-OCT), and to correlate with intraretinal changes and visual function. From a retrospectively reviewed series of 167 eyes with non-full-thickness macular holes, we exclusively included a subgroup of 34 eyes with LMH and LHEP by SD-OCT evaluation. In these eyes, area of LHEP, intraretinal changes of defect diameter, central retinal thickness, defects of the ellipsoid zone and occurrence of a contractive epiretinal membrane were analysed. Additionally, clinical data were documented. Area of LHEP significantly increased during a mean follow-up period of 40.5 months (median 52 months). Analysing intraretinal changes, a significant enlargement of minimum and maximum horizontal lamellar hole diameter was found that correlated with the area of LHEP. Defects of the ellipsoid zone were seen in 65% of the eyes at baseline and in 85% at the end of follow-up. Increase of maximum horizontal hole diameter and ellipsoid zone defects correlated with a decline of visual acuity. Fifty per cent of patients with LMH and LHEP also demonstrated extrafoveal typical contractive epiretinal membranes with retinal folds. Long-term follow-up revealed an increase of the area of LHEP in eyes with LMH that correlated with the enlargement of lamellar hole diameter and ellipsoid zone defects. Our data delineate the progression of intraretinal changes in association with a decline of visual function in this subgroup of LMH eyes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Correlation between spectral-domain OCT findings and visual acuity in X-linked retinoschisis.

    PubMed

    Yang, Hyun Seung; Lee, Jung Bok; Yoon, Young Hee; Lee, Joo Yong

    2014-05-08

    To investigate the tomographic characteristics of the outer retina and choroid and their relationship with visual acuity in X-linked juvenile retinoschisis (XLRS) patients using spectral-domain optical coherence tomography (SD-OCT). In this retrospective, observational, case-control study, we analyzed 20 eyes of 10 patients with XLRS using SD-OCT. The clinical and tomographic features of the outer retina, including the external limiting membrane (ELM), inner segment/outer segment (IS/OS) junction, cone cell outer segment tips (COST) line, photoreceptor outer segment (PROS) length, and choroid, were evaluated. As controls, 40 age-, sex-, and refraction-matched healthy eyes (1:2 matched) were randomly selected and imaged in parallel. The most prevalent area of abnormality in the outer retina layer of our patients was the outer plexiform layer (OPL; 60% of all affected eyes) and COST line (75% of all affected eyes). On average, the subfoveal choroid and PROS lengths were 35 μm thicker and 19 μm thinner, respectively, in XLRS patients (P = 0.084 and P < 0.001, respectively). A dominant IS/OS junction, COST line defects, and PROS length were related to patient best-corrected visual acuity (BCVA; P = 0.029, P = 0.001, and P < 0.001, respectively) by univariate analysis. Cone cell outer segment tips line defect and PROS length were the only factors related to BCVA in multivariate analysis (P = 0.028 and 0.003, respectively). Outer plexiform layer and photoreceptor microstructure defects are frequent in XLRS patients. Cone cell outer segment tips line defects and shortened PROS lengths as well as other photoreceptor microstructure defects may be closely related to poor vision in XLRS.

  18. Delayed Single Stage Perineal Posterior Urethroplasty.

    PubMed

    Ali, Shahzad; Shahnawaz; Shahzad, Iqbal; Baloch, Muhammad Umar

    2015-06-01

    To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Descriptive case series. Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patient's age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3%) experienced recurrent stricture during first 10 months. Five (16.6%) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6%) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3% with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures.

  19. Effects of thickness and gain on the amplitude of airborne ultrasonics

    USDA-ARS?s Scientific Manuscript database

    Currently, hides and leather are visually inspected and ranked for quality, usable area, and sale price. However, visual inspection is not reliable for detecting defects, which are usually hidden inside the material. Development of a non-contact nondestructive method to accurately evaluate the qua...

  20. Simultaneous Implantation of an Ahmed and Baerveldt Glaucoma Drainage Device for Uncontrolled Intraocular Pressure in Advanced Glaucoma.

    PubMed

    Rao, Veena S; Christenbury, Joseph; Lee, Paul; Allingham, Rand; Herndon, Leon; Challa, Pratap

    2017-02-01

    To evaluate efficacy and safety of a novel technique, simultaneous implantation of Ahmed and Baerveldt shunts, for improved control of intraocular pressure (IOP) in advanced glaucoma with visual field defects threatening central fixation. Retrospective case series; all patients receiving simultaneous Ahmed and Baerveldt implantation at a single institution between October 2004 and October 2009 were included. Records were reviewed preoperatively and at postoperative day 1, week 1, month 1, month 3, month 6, year 1, and yearly until year 5. Outcome measures included IOP, best-corrected visual acuity, visual field mean deviation, cup to disc ratio, number of glaucoma medications, and complications. Fifty-nine eyes were identified; mean (±SD) follow-up was 26±23 months. Primary open-angle glaucoma was most common (n=37, 63%). Forty-six eyes (78%) had prior incisional surgery. Mean preoperative IOP was 25.5±9.8 mm Hg. IOP was reduced 50% day 1 (P<0.001, mean 12.7±7.0 mm Hg), which persisted throughout follow-up. At year 1, cup to disc ratio and mean deviation were stable with decreased best-corrected visual acuity from logMAR 0.72±0.72(20/100) to 1.06±1.13(20/200) (P=0.007). The Kaplan-Meier survival analysis showed median and mean survival of 1205 and 829±91 days, respectively. Complication rate was 47%. IOP is markedly reduced postoperative day 1 following double glaucoma tube implantation with effects persisting over postoperative year 1 and up to year 5. Complications were higher than that seen in reports of single shunt implantation, which may be explained by patient complexity in this cohort. This technique may prove a promising novel approach for management of uncontrolled IOP in advanced glaucoma.

  1. Mechanisms of oxygen permeation through plastic films and barrier coatings

    NASA Astrophysics Data System (ADS)

    Wilski, Stefan; Wipperfürth, Jens; Jaritz, Montgomery; Kirchheim, Dennis; Mitschker, Felix; Awakowicz, Peter; Dahlmann, Rainer; Hopmann, Christian

    2017-10-01

    Oxygen and water vapour permeation through plastic films in food packaging or other applications with high demands on permeation are prevented by inorganic barrier films. Most of the permeation occurs through small defects (<3 µm) in the barrier coating. The defects were visualized by etching with reactive oxygen in a capacitively coupled plasma and subsequent SEM imaging. In this work, defects in SiO x -coatings deposited by plasma-enhanced chemical vapour deposition on polyethylene terephthalate (PET) are investigated and the mass transport through the polymer is simulated in a 3D approach. Calculations of single defects showed that there is no linear correlation between the defect area and the resulting permeability. The influence of adjacent defects in different distances was observed and led to flow reduction functions depending on the defect spacing and defect area. A critical defect spacing where no interaction between defects occurs was found and compared to other findings. According to the superposition principle, the permeability of single defects was added up and compared to experimentally determined oxygen permeation. The results showed the same trend of decreasing permeability with decreasing defect densities.

  2. Are All Retinal Nerve Fiber Layer Defects on Optic Coherence Tomography Glaucomatous?

    PubMed Central

    Gür Güngör, Sirel; Ahmet, Akman

    2017-01-01

    Objectives: In this study, we investigated the patients who were referred to our clinic with a prediagnosis of glaucoma based on retinal nerve fiber layer (RNFL) defects on optic coherence tomography (OCT) but were determined to have nonglaucomatous RNLF defects upon detailed examination. Materials and Methods: The ophthalmic examination notes, OCT images, Heidelberg retinal tomography (HRT) II and fundus photographs of 357 patients were retrospectively evaluated. Final diagnoses of these patients were investigated. Results: Of the 357 patients, 216 (60.5%) were diagnosed as open angle glaucoma, 33 (9.2%) as low-tension glaucoma, 39 (10.9%) as pre-perimetric glaucoma. The ophthalmic examinations of 14 patients (3.9%) were normal and there were no RNFL defects in OCT examinations after dilatation. In 39 patients (10.9%), the ophthalmic and optic disc examinations were completely normal and no etiologic factor explaining RNFL defects was found. Twenty-two eyes of 16 patients (4.5%) were included in this study (the mean age was 53.8±11.5 years; 9 men and 7 women). After detailed questioning of the medical history and systemic and neurologic examinations, a diagnosis of ischemic optic neuropathy was made in 11 eyes (10 patients) (2.8%), optic neuritis in 3 eyes (2 patients) (0.6%), optic disc drusen in 4 eyes (2 patients) (0.6%), pseudotumor cerebri in 2 eyes (1 patient) (0.3%), and cerebral palsy in 2 eyes (1 patient) (0.3%). Conclusion: Decrease in RNFL thickness on OCT images alone may be misleading in glaucoma examination. In cases where optic disc cupping is not evident, diagnosis should not be based on OCT RNFL examinations alone, and the patient’s medical history, detailed ophthalmic examination, OCT optic disc parameters, HRT, and visual field tests should all be carefully evaluated together. PMID:29109895

  3. Management of orbital lymphangioma using intralesional injection of OK-432

    PubMed Central

    Suzuki, Y.; Obana, A.; Gohto, Y.; Miki, T.; Otuka, H.; Inoue, Y.

    2000-01-01

    AIM—To treat orbital lymphangioma with an intralesional injection of OK-432 (group A Streptococcus pyogenes of human origin).
METHOD—A 14 year old boy had a right orbital cystic lymphangioma. The visual acuity in the eye was 20/28. In an initial treatment, 0.02 mg of OK-432, was injected into the tumour after aspiration of the fluid contents, but no effect was seen. The second treatment was performed with 0.04 mg of OK-432.
RESULT—4 months later, the lesion had totally shrunk to fibrous tissue. The side effects were fever, a local inflammatory reaction lasting 3 days, and increased intraocular pressure, which was managed by draining the fluid contents. Visual acuity improved to 20/15, and the visual field defect and restriction of eye movement seen before treatment disappeared. No recurrence was noted 1 year after treatment.
CONCLUSION—An intralesional injection of OK-432 shrunk the lymphangioma without functional disturbance and scar in the facial skin. OK-432 may be useful for orbital lymphangioma, but further studies are still warranted to determine efficacy, complications, and the optimal dose for safe treatment.

 PMID:10837387

  4. Constructing a statistical atlas of the radii of the optic nerve and cerebrospinal fluid sheath in young healthy adults

    NASA Astrophysics Data System (ADS)

    Harrigan, Robert L.; Plassard, Andrew J.; Mawn, Louise A.; Galloway, Robert L.; Smith, Seth A.; Landman, Bennett A.

    2015-03-01

    Optic neuritis is a sudden inflammation of the optic nerve (ON) and is marked by pain on eye movement, and visual symptoms such as a decrease in visual acuity, color vision, contrast and visual field defects. The ON is closely linked with multiple sclerosis (MS) and patients have a 50% chance of developing MS within 15 years. Recent advances in multi-atlas segmentation methods have omitted volumetric assessment. In the past, measuring the size of the ON has been done by hand. We utilize a new method of automatically segmenting the ON to measure the radii of both the ON and surrounding cerebrospinal fluid (CSF) sheath to develop a normative distribution of healthy young adults. We examine this distribution for any trends and find that ON and CSF sheath radii do not vary between 20-35 years of age and between sexes. We evaluate how six patients suffering from optic neuropathy compare to this distribution of controls. We find that of these six patients, five of them qualitatively differ from the normative distribution which suggests this technique could be used in the future to distinguish between optic neuritis patients and healthy controls

  5. Pattern-reversal electroretinograms in unilateral glaucoma.

    PubMed

    Wanger, P; Persson, H E

    1983-06-01

    Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means from glaucomatous and opposite eyes was statistically significant. No differences were observed in flash ERGs or OPs. The histopathologic correlate to the visual field defects in glaucoma is retinal ganglion cell degeneration. The present electrophysiologic findings support the view, based on results from animal experiments, that the pattern-reversal ERG reflects ganglion cell activity.

  6. Developmental neurogenetics and neuro-ophthalmology.

    PubMed

    Bennett, Jeffrey L

    2002-12-01

    The field of developmental neurogenetics has burgeoned over the past decade. Through the combined efforts of developmental biologists, geneticists, and clinicians, genetic defects resulting in neuro-ophthalmic disorders such as holoprosencephaly, microphthalmia, dominant optic atrophy, and optic nerve colobomas have been identified and characterized at the molecular level. Experimental studies in model organisms are continuing to identify novel genes critical for ocular and central nervous system development. Mutations in some of these genes have revealed a spectrum of pathology similar to that observed in septo-optic dysplasia, Möebius syndrome, and Duane retraction syndrome. This review examines our current knowledge of the molecular genetics of neuro-ophthalmic disease and focuses on several candidate genes for afferent and efferent visual system disorders.

  7. Unilateral glaucoma in Sotos syndrome (cerebral gigantism).

    PubMed

    Yen, M T; Gedde, S J; Flynn, J T

    2000-12-01

    To report a patient with unilateral glaucoma associated with Sotos syndrome. Sotos syndrome (cerebral gigantism) is a disorder of growth and development with characteristic facial changes and normal endocrine function. Ocular manifestations may also include megalocornea, iris hypoplasia, cataracts, megalophthalmos, strabismus, nystagmus, and retinal dystrophy. Case report. A 50 year-old man with the clinical features of Sotos syndrome presented with complaints of decreased vision in the left eye. Ophthalmologic examination revealed bilateral megalocornea, megalophthalmos, iris hypoplasia and transillumination defects, cataracts, and unilateral glaucoma. Intraocular pressure was lowered, and visual field loss was stabilized with topical medications. Sotos syndrome patients should be examined routinely to allow for early detection and treatment of potential ocular problems, including glaucoma.

  8. Hysteresis in single and polycrystalline iron thin films: Major and minor loops, first order reversal curves, and Preisach modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Yue; Xu, Ke; Jiang, Weilin

    Hysteretic behavior was studied in a series of Fe thin films, grown by molecular beam epitaxy, having different grain sizes and grown on different substrates. Major and minor loops and first order reversal curves (FORCs) were collected to investigate magnetization mechanisms and domain behavior under different magnetic histories. The minor loop coefficient and major loop coercivity increase with decreasing grain size due to higher defect concentration resisting domain wall movement. First order reversal curves allowed estimation of the contribution of irreversible and reversible susceptibilities and switching field distribution. The differences in shape of the major loops and first order reversalmore » curves are described using a classical Preisach model with distributions of hysterons of different switching fields, providing a powerful visualization tool to help understand the magnetization switching behavior of Fe films as manifested in various experimental magnetization measurements.« less

  9. Hysteresis in single and polycrystalline iron thin films: Major and minor loops, first order reversal curves, and Preisach modeling

    DOE PAGES

    Cao, Yue; Xu, Ke; Jiang, Weilin; ...

    2015-07-03

    Hysteretic behavior was studied in a series of Fe thin films, grown by molecular beam epitaxy, having different grain sizes and grown on different substrates. Major and minor loops and first order reversal curves (FORCs) were collected to investigate magnetization mechanisms and domain behavior under different magnetic histories. The minor loop coefficient and major loop coercivity increase with decreasing grain size due to higher defect concentration resisting domain wall movement. First order reversal curves allowed estimation of the contribution of irreversible and reversible susceptibilities and switching field distribution. The differences in shape of the major loops and first order reversalmore » curves are described using a classical Preisach model with distributions of hysterons of different switching fields, providing a powerful visualization tool to help understand the magnetization switching behavior of Fe films as manifested in various experimental magnetization measurements.« less

  10. Multiscale simulations of defect dipole-enhanced electromechanical coupling at dilute defect concentrations

    NASA Astrophysics Data System (ADS)

    Liu, Shi; Cohen, R. E.

    2017-08-01

    The role of defects in solids of mixed ionic-covalent bonds such as ferroelectric oxides is complex. Current understanding of defects on ferroelectric properties at the single-defect level remains mostly at the empirical level, and the detailed atomistic mechanisms for many defect-mediated polarization-switching processes have not been convincingly revealed quantum mechanically. We simulate the polarization-electric field (P-E) and strain-electric field (ɛ-E) hysteresis loops for BaTiO3 in the presence of generic defect dipoles with large-scale molecular dynamics and provide a detailed atomistic picture of the defect dipole-enhanced electromechanical coupling. We develop a general first-principles-based atomistic model, enabling a quantitative understanding of the relationship between macroscopic ferroelectric properties and dipolar impurities of different orientations, concentrations, and dipole moments. We find that the collective orientation of dipolar defects relative to the external field is the key microscopic structure feature that strongly affects materials hardening/softening and electromechanical coupling. We show that a small concentration (≈0.1 at. %) of defect dipoles dramatically improves electromechanical responses. This offers the opportunity to improve the performance of inexpensive polycrystalline ferroelectric ceramics through defect dipole engineering for a range of applications including piezoelectric sensors, actuators, and transducers.

  11. Activity-Dependent Dysfunction in Visual and Olfactory Sensory Systems in Mouse Models of Down Syndrome

    PubMed Central

    Saqran, Lubna; Herrick, Scott P.; Frosch, Matthew P.; Hyman, Bradley T.

    2017-01-01

    Activity-dependent synaptic plasticity plays a critical role in the refinement of circuitry during postnatal development and may be disrupted in conditions that cause intellectual disability, such as Down syndrome (DS). To test this hypothesis, visual cortical plasticity was assessed in Ts65Dn mice that harbor a chromosomal duplication syntenic to human chromosome 21q. We find that Ts65Dn mice demonstrate a defect in ocular dominance plasticity (ODP) following monocular deprivation. This phenotype is similar to that of transgenic mice that express amyloid precursor protein (APP), which is duplicated in DS and in Ts65DN mice; however, normalizing APP gene copy number in Ts65Dn mice fails to rescue plasticity. Ts1Rhr mice harbor a duplication of the telomeric third of the Ts65Dn-duplicated sequence and demonstrate the same ODP defect, suggesting a gene or genes sufficient to drive the phenotype are located in that smaller duplication. In addition, we find that Ts65Dn mice demonstrate an abnormality in olfactory system connectivity, a defect in the refinement of connections to second-order neurons in the olfactory bulb. Ts1Rhr mice do not demonstrate a defect in glomerular refinement, suggesting that distinct genes or sets of genes underlie visual and olfactory system phenotypes. Importantly, these data suggest that developmental plasticity and connectivity are impaired in sensory systems in DS model mice, that such defects may contribute to functional impairment in DS, and that these phenotypes, present in male and female mice, provide novel means for examining the genetic and molecular bases for neurodevelopmental impairment in model mice in vivo. SIGNIFICANCE STATEMENT Our understanding of the basis for intellectual impairment in Down syndrome is hindered by the large number of genes duplicated in Trisomy 21 and a lack of understanding of the effect of disease pathology on the function of neural circuits in vivo. This work describes early postnatal developmental abnormalities in visual and olfactory sensory systems in Down syndrome model mice, which provide insight into defects in the function of neural circuits in vivo and provide an approach for exploring the genetic and molecular basis for impairment in the disease. In addition, these findings raise the possibility that basic dysfunction in primary sensory circuitry may illustrate mechanisms important for global learning and cognitive impairment in Down syndrome patients. PMID:28899917

  12. BDA: A novel method for identifying defects in body-centered cubic crystals.

    PubMed

    Möller, Johannes J; Bitzek, Erik

    2016-01-01

    The accurate and fast identification of crystallographic defects plays a key role for the analysis of atomistic simulation output data. For face-centered cubic (fcc) metals, most existing structure analysis tools allow for the direct distinction of common defects, such as stacking faults or certain low-index surfaces. For body-centered cubic (bcc) metals, on the other hand, a robust way to identify such defects is currently not easily available. We therefore introduce a new method for analyzing atomistic configurations of bcc metals, the BCC Defect Analysis (BDA). It uses existing structure analysis algorithms and combines their results to uniquely distinguish between typical defects in bcc metals. In essence, the BDA method offers the following features:•Identification of typical defect structures in bcc metals.•Reduction of erroneously identified defects by iterative comparison to the defects in the atom's neighborhood.•Availability as ready-to-use Python script for the widespread visualization tool OVITO [http://ovito.org].

  13. Panoramic Night Vision Goggle Testing For Diagnosis and Repair

    DTIC Science & Technology

    2000-01-01

    Visual Acuity Visual Acuity [ Marasco & Task, 1999] measures how well a human observer can see high contrast targets at specified light levels through...grid through the PNVG in-board and out-board channels simultaneously and comparing the defects to the size of grid features ( Marasco & Task, 1999). The

  14. Techniques of Final Preseal Visual Inspection

    NASA Technical Reports Server (NTRS)

    Anstead, R. J.

    1975-01-01

    A dissertation is given on the final preseal visual inspection of microcircuit devices to detect manufacturing defects and reduce failure rates in service. The processes employed in fabricating monolithic integrated circuits and hybrid microcircuits, various failure mechanisms resulting from deficiencies in those processes, and the rudiments of performing final inspection are outlined.

  15. [Histologic assessment of tissue healing of hyaline cartilage by use of semiquantitative evaluation scale].

    PubMed

    Vukasović, Andreja; Ivković, Alan; Jezek, Davor; Cerovecki, Ivan; Vnuk, Drazen; Kreszinger, Mario; Hudetz, Damir; Pećina, Marko

    2011-01-01

    Articular cartilage is an avascular and aneural tissue lacking lymph drainage, hence its inability of spontaneous repair following injury. Thus, it offers an interesting model for scientific research. A number of methods have been suggested to enhance cartilage repair, but none has yet produced significant success. The possible application of the aforementioned methods has brought about the necessity to evaluate their results. The objective of this study was to analyze results of a study of the effects of the use of TGF-beta gene transduced bone marrow clot on articular cartilage defects using ICRS visual histological assessment scale. The research was conducted on 28 skeletally mature sheep that were randomly assigned to four groups and surgically inflicted femoral chondral defects. The articular surfaces were then treated with TGF-beta1 gene transduced bone marrow clot (TGF group), GFP transduced bone marrow clot (GFP group), untransduced bone marrow clot (BM group) or left untreated (NC group). The analysis was performed by visual examination of cartilage samples and results were obtained using ICRS visual histological assessment scale. The results were subsequently subjected to statistical assessment using Kruskal-Wallis and Mann-Whitney tests. Kruskal-Wallis test yielded statistically significant difference with respect to cell distribution. Mann-Whitney test showed statistically significant difference between TGF and NC groups (P = 0.002), as well as between BM and NC groups (P = 0.002 with Bonferroni correction). Twenty-six of the twenty-eight samples were subjected to histologic and subsequent statistical analysis; two were discarded due to faulty histology technique. Our results indicated a level of certainty as to the positive effect of TGF-beta1 gene transduced bone marrow clot in restoration of articular cartilage defects. However, additional research is necessary in the field. One of the significant drawbacks on histologic assessment of cartilage samples were the errors in histologic preparation, for which some samples had to be discarded and significantly impaired the analytical quality of the others. Defects of structures surrounding the articular cartilage, e.g., subchondral bone or connective tissue, might also impair the quality of histologic analysis. Additional analyses, i.e. polarizing microscopy should be performed to determine the degree of integration of the newly formed tissue with the surrounding cartilage. The semiquantitative ICRS scale, although of great practical value, has limitations as to the objectivity of the assessment, taking into account the analytical ability of the evaluator, as well as the accuracy of semiquantitative analysis in comparison to the methods of quantitative analysis. Overall results of histologic analysis indicated that the application of TGF-beta1 gene transduced bone marrow clot could have measurable clinical effects on articular cartilage repair. The ICRS visual histological assessment scale is a valuable analytical method for cartilage repair evaluation. In this respect, further analyses of the method value would be of great importance.

  16. Linking log quality with product performance

    Treesearch

    D. W. Green; Robert Ross

    1997-01-01

    In the United States, log grading procedures use visual assessment of defects, in relation to the log scaling diameter, to estimate the yield of lumber that maybe expected from the log. This procedure was satisfactory when structural grades were based only on defect size and location. In recent years, however, structural products have increasingly been graded using a...

  17. Development Of Ultrasonic Testing Based On Delphi Program As A Learning Media In The Welding Material Study Of Detection And Welding Disables In The Environment Of Vocational Education

    NASA Astrophysics Data System (ADS)

    Dwi Cahyono, Bagus; Ainur, Chandra

    2018-04-01

    The development of science and technology has a direct impact on the preparation of qualified workers, including the preparation of vocational high school graduates. Law Number 20 the Year 2003 on National Education System explains that the purpose of vocational education is to prepare learners to be ready to work in certain fields. One of the learning materials in Vocational High School is welding and detecting welding defects. Introduction of welding and detecting welding defects, one way that can be done is by ultrasonic testing will be very difficult if only capitalize the book only. Therefore this study aims to adopt ultrasonic testing in a computer system. This system is called Delphi Program-based Ultrasonic Testing Expert System. This system is used to determine the classification and type of welding defects of the welded defect indicator knew. In addition to the system, there is a brief explanation of the notion of ultrasonic testing, calibration procedures and inspection procedures ultrasonic testing. In this system, ultrasonic input data testing that shows defects entered into the computer manually. This system is built using Delphi 7 software and Into Set Up Compiler as an installer. The method used in this research is Research and Development (R & D), with the following stages: (1) preliminary research; (2) manufacture of software design; (3) materials collection; (4) early product development; (5) validation of instructional media experts; (6) product analysis and revision; (8) media trials in learning; And (9) result of end product of instructional media. The result of the research shows that: (1) the result of feasibility test according to ultrasonic material testing expert that the system is feasible to be used as instructional media in welding material subject and welding defect detection in vocational education environment, because it contains an explanation about detection method of welding defect using method Ultrasonic testing in detail; (2) feasibility test results according to media experts, that this system has a very attractive visual, user friendly, compatible with windows and Linux and media size that is not too large; And (3) result of test by using data of indication of welding defect in PT PAL Surabaya, obtained classification data of welding defect in accordance with calculation of welding defect classification.

  18. Searching for biomarkers of CDKL5 disorder: early-onset visual impairment in CDKL5 mutant mice

    PubMed Central

    Mazziotti, Raffaele; Lupori, Leonardo; Sagona, Giulia; Gennaro, Mariangela; Della Sala, Grazia; Putignano, Elena

    2017-01-01

    Abstract CDKL5 disorder is a neurodevelopmental disorder still without a cure. Murine models of CDKL5 disorder have been recently generated raising the possibility of preclinical testing of treatments. However, unbiased, quantitative biomarkers of high translational value to monitor brain function are still missing. Moreover, the analysis of treatment is hindered by the challenge of repeatedly and non-invasively testing neuronal function. We analyzed the development of visual responses in a mouse model of CDKL5 disorder to introduce visually evoked responses as a quantitative method to assess cortical circuit function. Cortical visual responses were assessed in CDKL5 null male mice, heterozygous females, and their respective control wild-type littermates by repeated transcranial optical imaging from P27 until P32. No difference between wild-type and mutant mice was present at P25-P26 whereas defective responses appeared from P27-P28 both in heterozygous and homozygous CDKL5 mutant mice. These results were confirmed by visually evoked potentials (VEPs) recorded from the visual cortex of a different cohort. The previously imaged mice were also analyzed at P60–80 using VEPs, revealing a persistent reduction of response amplitude, reduced visual acuity and defective contrast function. The level of adult impairment was significantly correlated with the reduction in visual responses observed during development. Support vector machine showed that multi-dimensional visual assessment can be used to automatically classify mutant and wt mice with high reliability. Thus, monitoring visual responses represents a promising biomarker for preclinical and clinical studies on CDKL5 disorder. PMID:28369421

  19. Personal factors influencing the visual reaction time of pedestrians to detect turn indicators in the presence of Daytime Running Lamps.

    PubMed

    Peña-García, Antonio; de Oña, Rocío; García, Pedro Antonio; de Oña, Juan

    2016-12-01

    Daytime running lamps (DRL) on vehicles have proven to be an effective measure to prevent accidents during the daytime, particularly when pedestrians and cyclists are involved. However, there are negative interactions of DRL with other functions in automotive lighting, such as delays in pedestrians' visual reaction time (VRT) when turn indicators are activated in the presence of DRL. These negative interactions need to be reduced. This work analyses the influence of variables inherent to pedestrians, such as height, gender and visual defects, on the VRT using a classification and regression tree as an exploratory analysis and a generalized linear model to validate the results. Some pedestrian characteristics, such as gender, alone or combined with the DRL colour, and visual defects, were found to have a statistically significant influence on VRT and, hence, on traffic safety. These results and conclusions concerning the interaction between pedestrians and vehicles are presented and discussed. Practitioner Summary: Visual interactions of vehicle daytime running lamps (DRL) with other functions in automotive lighting, such as turn indicators, have an important impact on a vehicle's conspicuity for pedestrians. Depending on several factors inherent to pedestrians, the visual reaction time (VRT) can be remarkably delayed, which has implications in traffic safety.

  20. Effect of anisotropy on defect mode peculiarities in chiral liquid crystals

    NASA Astrophysics Data System (ADS)

    Gevorgyan, A. H.; Oganesyan, K. B.

    2018-01-01

    The effect of anisotropy on defect mode peculiarities in cholesteric liquid crystals is investigated. The light transmission through the cholesteric liquid crystal layer with an anisotropic layer defect inside is solved by Ambartsumian’s layer addition modified method. Two cases are considered. In the first case, it is assumed that the defect layer is non-absorbing, and the effect of refraction anisotropy on the reflection, relative photonic density of states and the total field intensity produced in the defect layer are studied. In the second case, the defect layer is assumed to be isotropic for refraction and anisotropic for absorption, and the influence of defect layer absorption anisotropy on reflection, absorption, relative photonic density of states and the total field intensity produced in the defect layer are investigated.

  1. Correcting intermittent central suppression improves binocular marksmanship.

    PubMed

    Hussey, Eric S

    2007-04-01

    Intermittent central suppression (ICS) is a defect in normal binocular (two-eyed) vision that causes confusion in visual detail. ICS is a repetitive intermittent loss of visual sensation in the central area of vision. As the central vision of either eye "turns on and off", aiming errors in sight can occur that must be corrected when both eyes are seeing again. Any aiming errors in sight might be expected to interfere with marksmanship during two-eyed seeing. We compared monocular (one-eyed, patched) and binocular (two-eyed) marksmanship with pistol shooting with an Army ROTC cadet before and after successful therapy for diagnosed ICS. Pretreatment, monocular marksmanship was significantly better than binocular marksmanship, suggesting defective binocularity reduced accuracy. After treatment for ICS, binocular and monocular marksmanship were essentially the same. Results confirmed predictions that with increased visual stability from correcting the suppression, binocular and monocular marksmanship accuracies should merge.

  2. Selective attention to imagined facial ugliness is specific to body dysmorphic disorder.

    PubMed

    Grocholewski, Anja; Kliem, Sören; Heinrichs, Nina

    2012-03-01

    Cognitive-behavioral models postulate that biases in selective attention are key factors contributing to susceptibility to and maintenance of body dysmorphic disorder (BDD). Visual attention in particular toward the imagined defect in appearance may be a crucial element. The present study therefore examined whether individuals with BDD showed increased visual attention to flaws in their own and in unfamiliar faces. Twenty individuals with BDD, 20 individuals with social phobia, and 20 mentally healthy individuals participated in an eye-tracking experiment. Participants were instructed to gaze at the photographs of 15 pictures of themselves and several unfamiliar faces. Only patients with BDD showed heightened selective visual attention to the imagined defect in their own face, as well to corresponding regions in other, unfamiliar faces. The results support the assumption that there is a specific attentional bias in BDD. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Weak scratch detection and defect classification methods for a large-aperture optical element

    NASA Astrophysics Data System (ADS)

    Tao, Xian; Xu, De; Zhang, Zheng-Tao; Zhang, Feng; Liu, Xi-Long; Zhang, Da-Peng

    2017-03-01

    Surface defects on optics cause optic failure and heavy loss to the optical system. Therefore, surface defects on optics must be carefully inspected. This paper proposes a coarse-to-fine detection strategy of weak scratches in complicated dark-field images. First, all possible scratches are detected based on bionic vision. Then, each possible scratch is precisely positioned and connected to a complete scratch by the LSD and a priori knowledge. Finally, multiple scratches with various types can be detected in dark-field images. To classify defects and pollutants, a classification method based on GIST features is proposed. This paper uses many real dark-field images as experimental images. The results show that this method can detect multiple types of weak scratches in complex images and that the defects can be correctly distinguished with interference. This method satisfies the real-time and accurate detection requirements of surface defects.

  4. [Clinico-statistical study on availability of Esterman disability score for assessment of mobility difficulty in patients with visual field loss].

    PubMed

    Yamagata, Yoshitaka; Terada, Yuko; Suzuki, Atsushi; Mimura, Osamu

    2010-01-01

    The visual efficiency scale currently adopted to determine the legal grade of visual disability associated with visual field loss in Japan is not appropriate for the evaluation of disability regarding daily living activities. We investigated whether Esterman disability score (EDS) is suitable for the assessment of mobility difficulty in patients with visual field loss. The correlation between the EDS calculated from Goldmann's kinetic visual field and the degree of subjective mobility difficulty determined by a questionnaire was investigated in 164 patients with visual field loss. The correlation between the EDS determined using a program built into the Humphrey field analyzer and that calculated from Goldmann's kinetic visual field was also investigated. The EDS based on the kinetic visual field was correlated well with the degree of subjective mobility difficulty, and the EDS measured using the Humphrey field analyzer could be estimated from the kinetic visual field-based EDS. Instead of the currently adopted visual efficiency scale, EDS should be employed for the assessment of mobility difficulty in patients with visual field loss, also to establish new judgment criteria concerning the visual field.

  5. Neuropathies of the optic nerve and visual evoked potentials with special reference to color vision and differential light threshold measured with the computer perimeter OCTOPUS.

    PubMed

    Wildberger, H

    1984-10-31

    The contrast evoked potentials (VEPs) to different check sizes were recorded in about 200 cases of discrete optic neuropathies (ON) of different origin. Differential light threshold (DLT) was tested with the computer perimeter OCTOPUS. Saturated and desaturated tests were applied to evaluate the degree of acquired color vision deficiency. Delayed VEP responses are not confined to optic neuritis (RBN) alone and the different latency times obtained from other ON are confluent. The delay may be due to demyelination, to an increasing dominance of paramacular VEP subcomponents or to an increasing dominance of the upper half-field responses. Recording with smaller check sizes has the advantage that discrete dysfunctions in the visual field (VF) center are more easily detected: a correlation between amplitudes and visual acuity is best in strabismic amblyopias, is less expressed in maculopathies of the retina and weak in ON. The absence or reduction of amplitudes to smaller check sizes, however, is an important indication of a disorder in the VF center of ON in an early or recovered stage. Acquired color vision defects of the tritan-like type are more confined to discrete ON, whereas the red/green type is reserved to more severe ON. The DLT of the VF center is reduced in a different, significant and non significant extent in discrete optic neuropathies and the correlation between DLT and visual acuity is weak. A careful numerical analysis is needed in types of discrete ON where the central DLT lies within normal statistical limits: a side difference of the DLT between the affected and the normal fellow eye is always present. Evaluation of visual fatigue effects and of the relative sensitivity loss of VF center and VF periphery may provide further diagnostic information.

  6. Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury

    NASA Astrophysics Data System (ADS)

    Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.

    2008-02-01

    Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.

  7. Enhanced capture rate for haze defects in production wafer inspection

    NASA Astrophysics Data System (ADS)

    Auerbach, Ditza; Shulman, Adi; Rozentsvige, Moshe

    2010-03-01

    Photomask degradation via haze defect formation is an increasing troublesome yield problem in the semiconductor fab. Wafer inspection is often utilized to detect haze defects due to the fact that it can be a bi-product of process control wafer inspection; furthermore, the detection of the haze on the wafer is effectively enhanced due to the multitude of distinct fields being scanned. In this paper, we demonstrate a novel application for enhancing the wafer inspection tool's sensitivity to haze defects even further. In particular, we present results of bright field wafer inspection using the on several photo layers suffering from haze defects. One way in which the enhanced sensitivity can be achieved in inspection tools is by using a double scan of the wafer: one regular scan with the normal recipe and another high sensitivity scan from which only the repeater defects are extracted (the non-repeater defects consist largely of noise which is difficult to filter). Our solution essentially combines the double scan into a single high sensitivity scan whose processing is carried out along two parallel routes (see Fig. 1). Along one route, potential defects follow the standard recipe thresholds to produce a defect map at the nominal sensitivity. Along the alternate route, potential defects are used to extract only field repeater defects which are identified using an optimal repeater algorithm that eliminates "false repeaters". At the end of the scan, the two defect maps are merged into one with optical scan images available for all the merged defects. It is important to note, that there is no throughput hit; in addition, the repeater sensitivity is increased relative to a double scan, due to a novel runtime algorithm implementation whose memory requirements are minimized, thus enabling to search a much larger number of potential defects for repeaters. We evaluated the new application on photo wafers which consisted of both random and haze defects. The evaluation procedure involved scanning with three different recipe types: Standard Inspection: Nominal recipe with a low false alarm rate was used to scan the wafer and repeaters were extracted from the final defect map. Haze Monitoring Application: Recipe sensitivity was enhanced and run on a single field column from which on repeating defects were extracted. Enhanced Repeater Extractor: Defect processing included the two parallel routes: a nominal recipe for the random defects and the new high sensitive repeater extractor algorithm. The results showed that the new application (recipe #3) had the highest capture rate on haze defects and detected new repeater defects not found in the first two recipes. In addition, the recipe was much simpler to setup since repeaters are filtered separately from random defects. We expect that in the future, with the advent of mask-less lithography and EUV lithography, the monitoring of field and die repeating defects on the wafer will become a necessity for process control in the semiconductor fab.

  8. Direct Visualization of Local Electromagnetic Field Structures by Scanning Transmission Electron Microscopy.

    PubMed

    Shibata, Naoya; Findlay, Scott D; Matsumoto, Takao; Kohno, Yuji; Seki, Takehito; Sánchez-Santolino, Gabriel; Ikuhara, Yuichi

    2017-07-18

    The functional properties of materials and devices are critically determined by the electromagnetic field structures formed inside them, especially at nanointerface and surface regions, because such structures are strongly associated with the dynamics of electrons, holes and ions. To understand the fundamental origin of many exotic properties in modern materials and devices, it is essential to directly characterize local electromagnetic field structures at such defect regions, even down to atomic dimensions. In recent years, rapid progress in the development of high-speed area detectors for aberration-corrected scanning transmission electron microscopy (STEM) with sub-angstrom spatial resolution has opened new possibilities to directly image such electromagnetic field structures at very high-resolution. In this Account, we give an overview of our recent development of differential phase contrast (DPC) microscopy for aberration-corrected STEM and its application to many materials problems. In recent years, we have developed segmented-type STEM detectors which divide the detector plane into 16 segments and enable simultaneous imaging of 16 STEM images which are sensitive to the positions and angles of transmitted/scattered electrons on the detector plane. These detectors also have atomic-resolution imaging capability. Using these segmented-type STEM detectors, we show DPC STEM imaging to be a very powerful tool for directly imaging local electromagnetic field structures in materials and devices in real space. For example, DPC STEM can clearly visualize the local electric field variation due to the abrupt potential change across a p-n junction in a GaAs semiconductor, which cannot be observed by normal in-focus bright-field or annular type dark-field STEM imaging modes. DPC STEM is also very effective for imaging magnetic field structures in magnetic materials, such as magnetic domains and skyrmions. Moreover, real-time imaging of electromagnetic field structures can now be realized through very fast data acquisition, processing, and reconstruction algorithms. If we use DPC STEM for atomic-resolution imaging using a sub-angstrom size electron probe, it has been shown that we can directly observe the atomic electric field inside atoms within crystals and even inside single atoms, the field between the atomic nucleus and the surrounding electron cloud, which possesses information about the atomic species, local chemical bonding and charge redistribution between bonded atoms. This possibility may open an alternative way for directly visualizing atoms and nanostructures, that is, seeing atoms as an entity of electromagnetic fields that reflect the intra- and interatomic electronic structures. In this Account, the current status of aberration-corrected DPC STEM is highlighted, along with some applications in real material and device studies.

  9. Biomarkers in primary open angle glaucoma.

    PubMed

    Kokotas, Haris; Kroupis, Christos; Chiras, Dimitrios; Grigoriadou, Maria; Lamnissou, Klea; Petersen, Michael B; Kitsos, George

    2012-12-01

    Glaucoma, a leading cause of blindness worldwide, is currently defined as a disturbance of the structural or functional integrity of the optic nerve that causes characteristic atrophic changes in the optic nerve, which may lead to specific visual field defects over time. This disturbance usually can be arrested or diminished by adequate lowering of intraocular pressure (IOP). Glaucoma can be divided roughly into two main categories, ‘ open angle ’ and ‘ closed angle ’ glaucoma.Open angle, chronic glaucoma tends to progress at a slower rate and patients may not notice loss of vision until the disease has progressed significantly. Primary open angle glaucoma(POAG) is described distinctly as a multifactorial optic neuropathy that is chronic and progressive with a characteristic acquired loss of optic nerve fibers. Such loss develops in the presence of open anterior chamber angles, characteristic visual field abnormalities, and IOP that is too high for the healthy eye. It manifests by cupping and atrophy of the optic disc, in the absence of other known causes of glaucomatous disease. Several biological markers have been implicated with the disease. The purpose of this study was to summarize the current knowledge regarding the non-genetic molecular markers which have been predicted to have an association with POAG but have not yet been validated.

  10. Clinically non-functioning pituitary adenomas: Pathogenic, diagnostic and therapeutic aspects.

    PubMed

    Mercado, Moises; Melgar, Virgilio; Salame, Latife; Cuenca, Dalia

    Clinically non-functioning pituitary adenomas (NFPAs) are among the most common tumors in the sellar region. These lesions do not cause a hormonal hypersecretion syndrome, and are therefore found incidentally (particularly microadenomas) or diagnosed based on compressive symptoms such as headache and visual field defects, as well as clinical signs of pituitary hormone deficiencies. Immunohistochemically, more than 45% of these adenomas stain for gonadotropins or their subunits and are therefore called gonadotropinomas, while 30% of them show no immunostaining for any hormone and are known as null cell adenomas. The diagnostic approach to NFPAs should include visual field examination, an assessment of the integrity of all anterior pituitary hormone systems, and magnetic resonance imaging of the sellar region to define tumor size and extension. The treatment of choice is transsphenoidal resection of the adenoma, which in many instances cannot be completely accomplished. The recurrence rate after surgery may be up to 30%. Persistent or recurrent adenomas are usually treated with radiation therapy. In a small proportion of these cases, drug treatment with dopamine agonists and, to a lesser extent, somatostatin analogs may achieve reduction or at least stabilization of the tumor. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. A Novel Active Imaging Model to Design Visual Systems: A Case of Inspection System for Specular Surfaces

    PubMed Central

    Azorin-Lopez, Jorge; Fuster-Guillo, Andres; Saval-Calvo, Marcelo; Mora-Mora, Higinio; Garcia-Chamizo, Juan Manuel

    2017-01-01

    The use of visual information is a very well known input from different kinds of sensors. However, most of the perception problems are individually modeled and tackled. It is necessary to provide a general imaging model that allows us to parametrize different input systems as well as their problems and possible solutions. In this paper, we present an active vision model considering the imaging system as a whole (including camera, lighting system, object to be perceived) in order to propose solutions to automated visual systems that present problems that we perceive. As a concrete case study, we instantiate the model in a real application and still challenging problem: automated visual inspection. It is one of the most used quality control systems to detect defects on manufactured objects. However, it presents problems for specular products. We model these perception problems taking into account environmental conditions and camera parameters that allow a system to properly perceive the specific object characteristics to determine defects on surfaces. The validation of the model has been carried out using simulations providing an efficient way to perform a large set of tests (different environment conditions and camera parameters) as a previous step of experimentation in real manufacturing environments, which more complex in terms of instrumentation and more expensive. Results prove the success of the model application adjusting scale, viewpoint and lighting conditions to detect structural and color defects on specular surfaces. PMID:28640211

  12. Visual Agnosia and Posterior Cerebral Artery Infarcts: An Anatomical-Clinical Study

    PubMed Central

    Martinaud, Olivier; Pouliquen, Dorothée; Gérardin, Emmanuel; Loubeyre, Maud; Hirsbein, David; Hannequin, Didier; Cohen, Laurent

    2012-01-01

    Background To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA) strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. Methods and Findings We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct) with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA), faces (FFA and OFA), houses (PPA) and common objects (LOC). Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words). Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. Conclusions Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations. PMID:22276198

  13. Visual agnosia and posterior cerebral artery infarcts: an anatomical-clinical study.

    PubMed

    Martinaud, Olivier; Pouliquen, Dorothée; Gérardin, Emmanuel; Loubeyre, Maud; Hirsbein, David; Hannequin, Didier; Cohen, Laurent

    2012-01-01

    To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA) strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct) with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA), faces (FFA and OFA), houses (PPA) and common objects (LOC). Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words). Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations.

  14. Magnifying narrow-band imaging of gastric mucosal morphology predicts the H. pylori-related epigenetic field defect.

    PubMed

    Tahara, Tomomitsu; Yamazaki, Jumpei; Tahara, Sayumi; Okubo, Masaaki; Kawamura, Tomohiko; Horiguchi, Noriyuki; Ishizuka, Takamitsu; Nagasaka, Mitsuo; Nakagawa, Yoshihito; Shibata, Tomoyuki; Kuroda, Makoto; Ohmiya, Naoki

    2017-06-08

    DNA methylation is associated with "field defect" in the gastric mucosa. To characterize "field defect" morphologically, we examined DNA methylation of non-neoplastic gastric mucosa in relation to their morphology seen by narrow-band imaging (NBI) with magnifying endoscopy. Magnifying NBI of non-neoplastic gastric body was classified as follows: normal-small and round pits with uniform subepithelial capillary networks; type 1-a little enlarged round pits with indistinct subepithelial capillary networks; type 2-remarkably enlarged pits with irregular vessels; and type 3-clearly demarcated oval or tubulovillous pits with bulky coiled or wavy vessels. Methylation of nine candidate genes (MYOD1, SLC16A12, GDNF, IGF2, MIR 124A1, CDH1, PRDM5, RORA and MLF1) were determined by bisulfite pyrosequencing. Infinium HumanMethylation450 array was used to characterize the methylation of >450,000 CpG sites. Mean Z score methylation of nine genes positively correlated with the changes of mucosal patterns from normal to types 1, 2, and 3 (P < 0.0001). Genome-wide analysis showed that development of mucosal patterns correlated with methylation accumulation especially at CpG islands. Genes with promoter CpG islands that were gradually methylated with the development of mucosal patterns significantly enriched the genes involved in zinc-related pathways. The results indicates that gastric mucosal morphology predicts a "field defect" in this tissue type. Accumulation of DNA methylation is associated with "field defect" in the non-neoplastic gastric mucosa. Endoscopic identification of "field defect" has important implications for preventing gastric cancer. Our results suggest that magnifying NBI of gastric mucosal morphology predicts a "field defect" in the gastric mucosa.

  15. Transcriptome Profiling Identifies Multiplexin as a Target of SAGA Deubiquitinase Activity in Glia Required for Precise Axon Guidance During Drosophila Visual Development.

    PubMed

    Ma, Jingqun; Brennan, Kaelan J; D'Aloia, Mitch R; Pascuzzi, Pete E; Weake, Vikki M

    2016-08-09

    The Spt-Ada-Gcn5 Acetyltransferase (SAGA) complex is a transcriptional coactivator with histone acetylase and deubiquitinase activities that plays an important role in visual development and function. In Drosophila melanogaster, four SAGA subunits are required for the deubiquitination of monoubiquitinated histone H2B (ubH2B): Nonstop, Sgf11, E(y)2, and Ataxin 7. Mutations that disrupt SAGA deubiquitinase activity cause defects in neuronal connectivity in the developing Drosophila visual system. In addition, mutations in SAGA result in the human progressive visual disorder spinocerebellar ataxia type 7 (SCA7). Glial cells play a crucial role in both the neuronal connectivity defect in nonstop and sgf11 flies, and in the retinal degeneration observed in SCA7 patients. Thus, we sought to identify the gene targets of SAGA deubiquitinase activity in glia in the Drosophila larval central nervous system. To do this, we enriched glia from wild-type, nonstop, and sgf11 larval optic lobes using affinity-purification of KASH-GFP tagged nuclei, and then examined each transcriptome using RNA-seq. Our analysis showed that SAGA deubiquitinase activity is required for proper expression of 16% of actively transcribed genes in glia, especially genes involved in proteasome function, protein folding and axon guidance. We further show that the SAGA deubiquitinase-activated gene Multiplexin (Mp) is required in glia for proper photoreceptor axon targeting. Mutations in the human ortholog of Mp, COL18A1, have been identified in a family with a SCA7-like progressive visual disorder, suggesting that defects in the expression of this gene in SCA7 patients could play a role in the retinal degeneration that is unique to this ataxia. Copyright © 2016 Ma et al.

  16. The influence of naturalistic, directionally non-specific motion on the spatial deployment of visual attention in right-hemispheric stroke.

    PubMed

    Cazzoli, Dario; Hopfner, Simone; Preisig, Basil; Zito, Giuseppe; Vanbellingen, Tim; Jäger, Michael; Nef, Tobias; Mosimann, Urs; Bohlhalter, Stephan; Müri, René M; Nyffeler, Thomas

    2016-11-01

    An impairment of the spatial deployment of visual attention during exploration of static (i.e., motionless) stimuli is a common finding after an acute, right-hemispheric stroke. However, less is known about how these deficits: (a) are modulated through naturalistic motion (i.e., without directional, specific spatial features); and, (b) evolve in the subacute/chronic post-stroke phase. In the present study, we investigated free visual exploration in three patient groups with subacute/chronic right-hemispheric stroke and in healthy subjects. The first group included patients with left visual neglect and a left visual field defect (VFD), the second patients with a left VFD but no neglect, and the third patients without neglect or VFD. Eye movements were measured in all participants while they freely explored a traffic scene without (static condition) and with (dynamic condition) naturalistic motion, i.e., cars moving from the right or left. In the static condition, all patient groups showed similar deployment of visual exploration (i.e., as measured by the cumulative fixation duration) as compared to healthy subjects, suggesting that recovery processes took place, with normal spatial allocation of attention. However, the more demanding dynamic condition with moving cars elicited different re-distribution patterns of visual attention, quite similar to those typically observed in acute stroke. Neglect patients with VFD showed a significant decrease of visual exploration in the contralesional space, whereas patients with VFD but no neglect showed a significant increase of visual exploration in the contralesional space. No differences, as compared to healthy subjects, were found in patients without neglect or VFD. These results suggest that naturalistic motion, without directional, specific spatial features, may critically influence the spatial distribution of visual attention in subacute/chronic stroke patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. [Perimetric changes in advanced glaucoma].

    PubMed

    Feraru, Crenguta Ioana; Pantalon, Anca

    2011-01-01

    The evaluation of various perimetric aspects in advanced glaucoma stages correlated to morpho-functional changes. MATHERIAL AND METHOD: Retrospective clinical trial over a 10 months time period that included patients with advanced glaucoma stages, for which there have been recorded several computerised visual field tests (central 24-2 strategy, 10-2 strategy with either III or V--Goldman stimulus spot size) along with other morpho-funtional ocular paramaters: VA, lOP optic disk analysis. We included in our study 56 eyes from 45 patients. In most cases 89% it was an open angle glaucoma (either primary or secondary) Mean visual acuity was 0.45 +/- 0.28. Regarding the perimetric deficit 83% had advanced deficit, 9% moderate and 8% early visual changes. As perimetric type of defect we found a majority with general reduction of sensitivity (33 eyes) + ring shape scotoma. In 6 eyes (10.7%) having left only a central isle of vision we performed the central 10-2 strategy with III or V Goldmann stimulus spot size. Statistic analysis showed scarce correlation between the visual acuity and the quantitative perimetric parameters (MD and PSD), and variance analysis found present a multiple correlation parameter p = 0.07 that proves there is no liniary correspondence between the morpho-functional parameters: VA-MD(PSD) and C/D ratio. In advanced glaucoma stages, the perimetric changes are mostly severe. Perimetric evaluation is essential in these stages and needs to be individualised.

  18. Educational Attainment of 10-Year-Old Children with Treated and Untreated Visual Defects.

    ERIC Educational Resources Information Center

    Stewart-Brown, Sarah; And Others

    1985-01-01

    Children with visual impairments who participated in a 10-year survey were compared with peers on measures of intelligence, reading, mathematics, and sporting ability. Results are consistent with earlier findings of increased intelligence among Ss with myopia and slightly reduced intelligence among Ss with amblyopia. It was concluded that the…

  19. [New developments in 2005 for the management of visual deficit in the infant].

    PubMed

    Bursztyn, J

    2005-03-01

    The main progress in ophthalmopediatrics is the knowledge of the importance and efficacy of visual refraction defects screening. This screening has to be the earliest possible, allowing a glass equipment preventing complications: amblyopia, strabismus. This screening allows the same time screening of organic anomalies and early treatment.

  20. Long-term abstinent alcoholics have normal memory.

    PubMed

    Reed, R J; Grant, I; Rourke, S B

    1992-08-01

    It is generally believed that many non-Korsakoff alcoholics have subtle defects in memory. To determine whether such defects vary as a function of length of abstinence (LOA), we performed extensive memory testing with: (1) recently detoxified (n = 31; LOA-29 days); (2) intermediate-term abstinent (n = 28; LOA = 1.9 years); (3) long-term abstinent (n = 32; LOA-7.0 years) alcoholics; and (4) nonalcoholic controls (n = 37). All subjects were matched on age and education. Alcoholics were matched on years of alcoholic drinking. Memory measures were divided into the following domains: verbal learning, verbal recall, visual learning, visual recall, and paired associate learning. A series of MANOVAs were conducted that revealed a significant relationship between visual learning and length of abstinence, and a significant interaction between age and length of abstinence on visual recall. Long-term abstinent subjects were not significantly different from controls on any test. We conclude that memory disturbance demonstrable among recently detoxified alcoholics in the early weeks of their abstinence is not evident in demographically matched long-term abstinent alcoholics with similar drinking histories.

  1. Driving simulation in the clinic: testing visual exploratory behavior in daily life activities in patients with visual field defects.

    PubMed

    Hamel, Johanna; Kraft, Antje; Ohl, Sven; De Beukelaer, Sophie; Audebert, Heinrich J; Brandt, Stephan A

    2012-09-18

    Patients suffering from homonymous hemianopia after infarction of the posterior cerebral artery (PCA) report different degrees of constraint in daily life, despite similar visual deficits. We assume this could be due to variable development of compensatory strategies such as altered visual scanning behavior. Scanning compensatory therapy (SCT) is studied as part of the visual training after infarction next to vision restoration therapy. SCT consists of learning to make larger eye movements into the blind field enlarging the visual field of search, which has been proven to be the most useful strategy(1), not only in natural search tasks but also in mastering daily life activities(2). Nevertheless, in clinical routine it is difficult to identify individual levels and training effects of compensatory behavior, since it requires measurement of eye movements in a head unrestrained condition. Studies demonstrated that unrestrained head movements alter the visual exploratory behavior compared to a head-restrained laboratory condition(3). Martin et al.(4) and Hayhoe et al.(5) showed that behavior demonstrated in a laboratory setting cannot be assigned easily to a natural condition. Hence, our goal was to develop a study set-up which uncovers different compensatory oculomotor strategies quickly in a realistic testing situation: Patients are tested in the clinical environment in a driving simulator. SILAB software (Wuerzburg Institute for Traffic Sciences GmbH (WIVW)) was used to program driving scenarios of varying complexity and recording the driver's performance. The software was combined with a head mounted infrared video pupil tracker, recording head- and eye-movements (EyeSeeCam, University of Munich Hospital, Clinical Neurosciences). The positioning of the patient in the driving simulator and the positioning, adjustment and calibration of the camera is demonstrated. Typical performances of a patient with and without compensatory strategy and a healthy control are illustrated in this pilot study. Different oculomotor behaviors (frequency and amplitude of eye- and head-movements) are evaluated very quickly during the drive itself by dynamic overlay pictures indicating where the subjects gaze is located on the screen, and by analyzing the data. Compensatory gaze behavior in a patient leads to a driving performance comparable to a healthy control, while the performance of a patient without compensatory behavior is significantly worse. The data of eye- and head-movement-behavior as well as driving performance are discussed with respect to different oculomotor strategies and in a broader context with respect to possible training effects throughout the testing session and implications on rehabilitation potential.

  2. A prospective profile of visual field loss following stroke: prevalence, type, rehabilitation, and outcome.

    PubMed

    Rowe, Fiona J; Wright, David; Brand, Darren; Jackson, Carole; Harrison, Shirley; Maan, Tallat; Scott, Claire; Vogwell, Linda; Peel, Sarah; Akerman, Nicola; Dodridge, Caroline; Howard, Claire; Shipman, Tracey; Sperring, Una; Macdiarmid, Sonia; Freeman, Cicely

    2013-01-01

    To profile site of stroke/cerebrovascular accident, type and extent of field loss, treatment options, and outcome. Prospective multicentre cohort trial. Standardised referral and investigation protocol of visual parameters. 915 patients were recruited with a mean age of 69 years (SD 14). 479 patients (52%) had visual field loss. 51 patients (10%) had no visual symptoms. Almost half of symptomatic patients (n = 226) complained only of visual field loss: almost half (n = 226) also had reading difficulty, blurred vision, diplopia, and perceptual difficulties. 31% (n = 151) had visual field loss as their only visual impairment: 69% (n = 328) had low vision, eye movement deficits, or visual perceptual difficulties. Occipital and parietal lobe strokes most commonly caused visual field loss. Treatment options included visual search training, visual awareness, typoscopes, substitutive prisms, low vision aids, refraction, and occlusive patches. At followup 15 patients (7.5%) had full recovery, 78 (39%) had improvement, and 104 (52%) had no recovery. Two patients (1%) had further decline of visual field. Patients with visual field loss had lower quality of life scores than stroke patients without visual impairment. Stroke survivors with visual field loss require assessment to accurately define type and extent of loss, diagnose coexistent visual impairments, and offer targeted treatment.

  3. Defect dependence of the irreversibility line in Bi2Sr2CaCu2O8 single crystals

    NASA Astrophysics Data System (ADS)

    Lombardo, L. W.; Mitzi, D. B.; Kapitulnik, A.; Leone, A.

    1992-09-01

    The c-axis irreversibility line (IL) of pristine single-crystal Bi2Sr2CaCu2O8 is shown to exhibit three regimes: For fields less than 0.1 T, it obeys a power law, Hirr=H0(1-Tirr/Tc)μ, where μ and H0 vary with Tc. For fields greater than 2 T, the IL becomes linear with a slope of 0.7 T/K. For intermediate fields, there is a crossover region, which corresponds to the onset of collective vortex behavior. Defects produced by proton irradiation shift the IL in all three regimes: The high-field regime moves to higher temperatures, the low-field regime moves to lower temperatures, and the crossover to collective behavior becomes obscured. A maximal increase in the irreversibility temperature in the high-field regime is found to occur at a defect density of nearly one defect per vortex core disk.

  4. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

    PubMed Central

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-01-01

    Objective To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2  =  0.92 versus r2  =  0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (κ  =  0.87 v κ  =  0.75, p < 0.05). Conclusion MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine. PMID:15939722

  5. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation

    PubMed Central

    Bailey, Joseph; Hunze, Arvid

    2017-01-01

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5–200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400–30,800 mm3 with 1.2 × 10−3−1.6 × 10−3 µT/mm3. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation. PMID:28956855

  6. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation.

    PubMed

    Bailey, Joseph; Long, Nicholas; Hunze, Arvid

    2017-09-28

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5-200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400-30,800 mm³ with 1.2 × 10 -3 -1.6 × 10 -3 µT/mm³. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation.

  7. Searching for biomarkers of CDKL5 disorder: early-onset visual impairment in CDKL5 mutant mice.

    PubMed

    Mazziotti, Raffaele; Lupori, Leonardo; Sagona, Giulia; Gennaro, Mariangela; Della Sala, Grazia; Putignano, Elena; Pizzorusso, Tommaso

    2017-06-15

    CDKL5 disorder is a neurodevelopmental disorder still without a cure. Murine models of CDKL5 disorder have been recently generated raising the possibility of preclinical testing of treatments. However, unbiased, quantitative biomarkers of high translational value to monitor brain function are still missing. Moreover, the analysis of treatment is hindered by the challenge of repeatedly and non-invasively testing neuronal function. We analyzed the development of visual responses in a mouse model of CDKL5 disorder to introduce visually evoked responses as a quantitative method to assess cortical circuit function. Cortical visual responses were assessed in CDKL5 null male mice, heterozygous females, and their respective control wild-type littermates by repeated transcranial optical imaging from P27 until P32. No difference between wild-type and mutant mice was present at P25-P26 whereas defective responses appeared from P27-P28 both in heterozygous and homozygous CDKL5 mutant mice. These results were confirmed by visually evoked potentials (VEPs) recorded from the visual cortex of a different cohort. The previously imaged mice were also analyzed at P60-80 using VEPs, revealing a persistent reduction of response amplitude, reduced visual acuity and defective contrast function. The level of adult impairment was significantly correlated with the reduction in visual responses observed during development. Support vector machine showed that multi-dimensional visual assessment can be used to automatically classify mutant and wt mice with high reliability. Thus, monitoring visual responses represents a promising biomarker for preclinical and clinical studies on CDKL5 disorder. © The Author 2017. Published by Oxford University Press.

  8. An open-architecture approach to defect analysis software for mask inspection systems

    NASA Astrophysics Data System (ADS)

    Pereira, Mark; Pai, Ravi R.; Reddy, Murali Mohan; Krishna, Ravi M.

    2009-04-01

    Industry data suggests that Mask Inspection represents the second biggest component of Mask Cost and Mask Turn Around Time (TAT). Ever decreasing defect size targets lead to more sensitive mask inspection across the chip, thus generating too many defects. Hence, more operator time is being spent in analyzing and disposition of defects. Also, the fact that multiple Mask Inspection Systems and Defect Analysis strategies would typically be in use in a Mask Shop or a Wafer Foundry further complicates the situation. In this scenario, there is a need for a versatile, user friendly and extensible Defect Analysis software that reduces operator analysis time and enables correct classification and disposition of mask defects by providing intuitive visual and analysis aids. We propose a new vendor-neutral defect analysis software, NxDAT, based on an open architecture. The open architecture of NxDAT makes it easily extensible to support defect analysis for mask inspection systems from different vendors. The capability to load results from mask inspection systems from different vendors either directly or through a common interface enables the functionality of establishing correlation between inspections carried out by mask inspection systems from different vendors. This capability of NxDAT enhances the effectiveness of defect analysis as it directly addresses the real-life scenario where multiple types of mask inspection systems from different vendors co-exist in mask shops or wafer foundries. The open architecture also potentially enables loading wafer inspection results as well as loading data from other related tools such as Review Tools, Repair Tools, CD-SEM tools etc, and correlating them with the corresponding mask inspection results. A unique concept of Plug-In interface to NxDAT further enhances the openness of the architecture of NxDAT by enabling end-users to add their own proprietary defect analysis and image processing algorithms. The plug-in interface makes it possible for the end-users to make use of their collected knowledge through the years of experience in mask inspection process by encapsulating the knowledge into software utilities and plugging them into NxDAT. The plug-in interface is designed with the intent of enabling the pro-active mask defect analysis teams to build competitive differentiation into their defect analysis process while protecting their knowledge internally within their company. By providing interface with all major standard layout and mask data formats, NxDAT enables correlation of defect data on reticles with design and mask databases, further extending the effectiveness of defect analysis for D2DB inspection. NxDAT also includes many other advanced features for easy and fast navigation, visual display of defects, defect selection, multi-tier classification, defect clustering and gridding, sophisticated CD and contact measurement analysis, repeatability analysis such as adder analysis, defect trend, capture rate etc.

  9. Characterization and manipulation of individual defects in insulating hexagonal boron nitride using scanning tunnelling microscopy.

    PubMed

    Wong, Dillon; Velasco, Jairo; Ju, Long; Lee, Juwon; Kahn, Salman; Tsai, Hsin-Zon; Germany, Chad; Taniguchi, Takashi; Watanabe, Kenji; Zettl, Alex; Wang, Feng; Crommie, Michael F

    2015-11-01

    Defects play a key role in determining the properties and technological applications of nanoscale materials and, because they tend to be highly localized, characterizing them at the single-defect level is of particular importance. Scanning tunnelling microscopy has long been used to image the electronic structure of individual point defects in conductors, semiconductors and ultrathin films, but such single-defect electronic characterization remains an elusive goal for intrinsic bulk insulators. Here, we show that individual native defects in an intrinsic bulk hexagonal boron nitride insulator can be characterized and manipulated using a scanning tunnelling microscope. This would typically be impossible due to the lack of a conducting drain path for electrical current. We overcome this problem by using a graphene/boron nitride heterostructure, which exploits the atomically thin nature of graphene to allow the visualization of defect phenomena in the underlying bulk boron nitride. We observe three different defect structures that we attribute to defects within the bulk insulating boron nitride. Using scanning tunnelling spectroscopy we obtain charge and energy-level information for these boron nitride defect structures. We also show that it is possible to manipulate the defects through voltage pulses applied to the scanning tunnelling microscope tip.

  10. The four-meter confrontation visual field test.

    PubMed Central

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests. PMID:1494829

  11. The four-meter confrontation visual field test.

    PubMed

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests.

  12. [Central nervous system dysgerminoma: a clinicopathological study of 3 cases].

    PubMed

    Bellil, Selma; Braham, Emna; Limaiem, Faten; Bellil, Khadija; Chelly, Ines; Mekni, Amina; Haouet, Slim; Zitouna, Moncef; Jemel, Hafedh; Khaldi, Moncef; Kchir, Nidhameddine

    2009-03-01

    Intracranial germ cell tumors are rarely seen and typically localize in the pineal or suprasellar region. The largest category of germ cell tumors is dysgerminoma. to describe clinicopathological features and immunohistochemical profile of dysgerminomas. We report three cases of central nervous system dysgerminomas. There were two young women and a man who were 6, 11 and 23-year-old. They presented with symptoms of insipidus diabetes (n=3) with association to visual field defects in the third case. Radiological findings showed a supra seller lesion in two cases. Double localization in the pineal and suprasellar regions was seen in the third case. Histologic examination and immunohistochemical study of surgical specimen were consistent with primary central nervous system dysgerminoma.

  13. Operator product expansion for conformal defects

    NASA Astrophysics Data System (ADS)

    Fukuda, Masayuki; Kobayashi, Nozomu; Nishioka, Tatsuma

    2018-01-01

    We study the operator product expansion (OPE) for scalar conformal defects of any codimension in CFT. The OPE for defects is decomposed into "defect OPE blocks", the irreducible representations of the conformal group, each of which packages the contribution from a primary operator and its descendants. We use the shadow formalism to deduce an integral representation of the defect OPE blocks. They are shown to obey a set of constraint equations that can be regarded as equations of motion for a scalar field propagating on the moduli space of the defects. By employing the Radon transform between the AdS space and the moduli space, we obtain a formula of constructing an AdS scalar field from the defect OPE block for a conformal defect of any codimension in a scalar representation of the conformal group, which turns out to be the Euclidean version of the HKLL formula. We also introduce a duality between conformal defects of different codimensions and prove the equivalence between the defect OPE block for codimension-two defects and the OPE block for a pair of local operators.

  14. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    PubMed

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially decrease the incidence of delayed visual deficits. As the results of endovascular therapy and specifically flow diverters become known, they warrant comparison with these surgical benchmarks to determine best practices.

  15. Visual Inspection Reliability for Precision Manufactured Parts.

    PubMed

    See, Judi E

    2015-12-01

    Sandia National Laboratories conducted an experiment for the National Nuclear Security Administration to determine the reliability of visual inspection of precision manufactured parts used in nuclear weapons. Visual inspection has been extensively researched since the early 20th century; however, the reliability of visual inspection for nuclear weapons parts has not been addressed. In addition, the efficacy of using inspector confidence ratings to guide multiple inspections in an effort to improve overall performance accuracy is unknown. Further, the workload associated with inspection has not been documented, and newer measures of stress have not been applied. Eighty-two inspectors in the U.S. Nuclear Security Enterprise inspected 140 parts for eight different defects. Inspectors correctly rejected 85% of defective items and incorrectly rejected 35% of acceptable parts. Use of a phased inspection approach based on inspector confidence ratings was not an effective or efficient technique to improve the overall accuracy of the process. Results did verify that inspection is a workload-intensive task, dominated by mental demand and effort. Hits for Nuclear Security Enterprise inspection were not vastly superior to the industry average of 80%, and they were achieved at the expense of a high scrap rate not typically observed during visual inspection tasks. This study provides the first empirical data to address the reliability of visual inspection for precision manufactured parts used in nuclear weapons. Results enhance current understanding of the process of visual inspection and can be applied to improve reliability for precision manufactured parts. © 2015, Human Factors and Ergonomics Society.

  16. Congenital Heart Defects in Adults : A Field Guide for Cardiologists

    PubMed Central

    Romfh, Anitra; Pluchinotta, Francesca Romana; Porayette, Prashob; Valente, Anne Marie; Sanders, Stephen P.

    2013-01-01

    Advances in cardiology and cardiac surgery allow a large proportion of patients with congenital heart defects to survive into adulthood. These patients frequently develop complications characteristic of the defect or its treatment. Consequently, adult cardiologists participating in the care of these patients need a working knowledge of the more common defects. Occasionally, patients with congenital heart defects such as atrial septal defect, Ebstein anomaly or physiologically corrected transposition of the great arteries present for the first time in adulthood. More often patients previously treated in pediatric cardiology centers have transitioned to adult congenital heart disease centers for ongoing care. Some of the more important defects in this category are tetralogy of Fallot, transposition of the great arteries, functionally single ventricle defects, and coarctation. Through this field guide, we provide an overview of the anatomy of selected defects commonly seen in an adult congenital practice using pathology specimens and clinical imaging studies. In addition, we describe the physiology, clinical presentation to the adult cardiologist, possible complications, treatment options, and outcomes. PMID:24294540

  17. Visuoperceptual impairment in dementia with Lewy bodies.

    PubMed

    Mori, E; Shimomura, T; Fujimori, M; Hirono, N; Imamura, T; Hashimoto, M; Tanimukai, S; Kazui, H; Hanihara, T

    2000-04-01

    In dementia with Lewy bodies (DLB), vision-related cognitive and behavioral symptoms are common, and involvement of the occipital visual cortices has been demonstrated in functional neuroimaging studies. To delineate visuoperceptual disturbance in patients with DLB in comparison with that in patients with Alzheimer disease and to explore the relationship between visuoperceptual disturbance and the vision-related cognitive and behavioral symptoms. Case-control study. Research-oriented hospital. Twenty-four patients with probable DLB (based on criteria of the Consortium on DLB International Workshop) and 48 patients with probable Alzheimer disease (based on criteria of the National Institute of Neurological and Communicative Disorders and Stroke-Alzheimer's Disease and Related Disorders Association) who were matched to those with DLB 2:1 by age, sex, education, and Mini-Mental State Examination score. Four test items to examine visuoperceptual functions, including the object size discrimination, form discrimination, overlapping figure identification, and visual counting tasks. Compared with patients with probable Alzheimer disease, patients with probable DLB scored significantly lower on all the visuoperceptive tasks (P<.04 to P<.001). In the DLB group, patients with visual hallucinations (n = 18) scored significantly lower on the overlapping figure identification (P = .01) than those without them (n = 6), and patients with television misidentifications (n = 5) scored significantly lower on the size discrimination (P<.001), form discrimination (P = .01), and visual counting (P = .007) than those without them (n = 19). Visual perception is defective in probable DLB. The defective visual perception plays a role in development of visual hallucinations, delusional misidentifications, visual agnosias, and visuoconstructive disability charcteristic of DLB.

  18. Color vision defects in adrenomyeloneuropathy.

    PubMed Central

    Sack, G H; Raven, M B; Moser, H W

    1989-01-01

    The relationship between abnormal color vision and adrenomyeloneuropathy (AMN) was investigated in 27 AMN patients and 31 age-matched controls by using the Farnsworth-Munsell 100 Hue test. Twelve (44%) of 27 patients showed test scores significantly above normal. The axes of bipolarity determined by the testing differed widely between the patients with abnormal scores, compatible with the notion that different alterations in visual pigment genes occur in different AMN kindreds. These observations confirm our earlier impression that the frequency of abnormal color vision is increased in these kindreds, and it supports our contentions that (1) AMN (and its companion, adrenoleukodystrophy) are very closely linked to the visual pigment loci at Xq28 and (2) this proximity might provide the opportunity to observe contiguous gene defects. PMID:2729274

  19. Brief Communication: visual-field superiority as a function of stimulus type and content: further evidence.

    PubMed

    Basu, Anamitra; Mandal, Manas K

    2004-07-01

    The present study examined visual-field advantage as a function of presentation mode (unilateral, bilateral), stimulus structure (facial, lexical), and stimulus content (emotional, neutral). The experiment was conducted in a split visual-field paradigm using a JAVA-based computer program with recognition accuracy as the dependent measure. Unilaterally, rather than bilaterally, presented stimuli were significantly better recognized. Words were significantly better recognized than faces in the right visual-field; the difference was nonsignificant in the left visual-field. Emotional content elicited left visual-field and neutral content elicited right visual-field advantages. Copyright Taylor and Francis Inc.

  20. Protection heater design validation for the LARP magnets using thermal imaging

    DOE PAGES

    Marchevsky, M.; Turqueti, M.; Cheng, D. W.; ...

    2016-03-16

    Protection heaters are essential elements of a quench protection scheme for high-field accelerator magnets. Various heater designs fabricated by LARP and CERN have been already tested in the LARP high-field quadrupole HQ and presently being built into the coils of the high-field quadrupole MQXF. In order to compare the heat flow characteristics and thermal diffusion timescales of different heater designs, we powered heaters of two different geometries in ambient conditions and imaged the resulting thermal distributions using a high-sensitivity thermal video camera. We observed a peculiar spatial periodicity in the temperature distribution maps potentially linked to the structure of themore » underlying cable. Two-dimensional numerical simulation of heat diffusion and spatial heat distribution have been conducted, and the results of simulation and experiment have been compared. Imaging revealed hot spots due to a current concentration around high curvature points of heater strip of varying cross sections and visualized thermal effects of various interlayer structural defects. Furthermore, thermal imaging can become a future quality control tool for the MQXF coil heaters.« less

  1. Mutation of the PAX6 gene in a sporadic patient with atypical aniridia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, D.; Li, Y.; Traboulsi, E.I.

    1994-09-01

    A 28 year-old man presented with poor vision since childhood and gradual further decline of several years duration. His visual acuity measures 20/200 OD with -11.50 + 0.50 x 150 and 20/100 OS with -12.25 + 0.25 x 35. He had a fine nystagmus. His visual fields were full. There was a circumferential pannus with areas of corneal stromal opacification. The iris was hypoplastic with atypical colobomatous defects. The lenses had scattered cortical opacities. The intraocular pressures were normal. The optic nerves had cup disk ratios of 0.6 OU. The family history was negative for similar defects. A diagnosis ofmore » aniridia was made and blood was drawn for analysis of the PAX6 gene. PCR amplification of exon 5 showed heterozygous fragments with one allele being larger than normal. Direct DNA sequencing of the individual heterozygous allele showed a 41 base pair insertion at nucleotide 483 in exon 5 of the paired domain. This frameshift mutation changed codon 71 to a stop codon. The diagnosis of aniridia was confirmed in this atypical patient, who will need to be monitored for his high risk of glaucoma. The risk of developing Wilms` tumor in patients with mutations within the aniridia gene is presumably negligible since the neighboring Wilms` tumor gene is unaffected. The identification of intragenic mutations of the PAX6 gene in patients with sporadic aniridia modifies the management of such patients because of recognition of the increased risk of glaucoma and by reducing the necessity for frequent monitoring for the presence of Wilms` tumor.« less

  2. [Eclipse retinopathy : A case series after the partial solar eclipse on 20 March 2015].

    PubMed

    Bachmeier, I; Helbig, H; Greslechner, R

    2017-01-01

    Solar retinopathy refers to damage to the central macula caused by exposure to intense solar radiation, most frequently observed after a solar eclipse. Description of the morphological changes in spectral domain optical coherence tomography (SD-OCT) and the clinical course in patients with acute solar retinopathy. The study included a retrospective analysis of 12 eyes from 7 patients with solar retinopathy after the partial solar eclipse on 20 March 2015. Best corrected visual acuity, fundus changes and SD-OCT findings were analyzed. Out of the 7 patients 5 underwent treatment with 1 mg prednisolone per kg body weight. The average age of the patients was 30.1±13.1 years. Best corrected visual acuity was 0.65 at initial presentation. In the acute stage all affected eyes showed a small yellowish lesion in the centre of the fovea in the fundoscopic examination. In SD-OCT the continuity of all layers in the foveola appeared disrupted. In the follow-up examination these changes were partially resolved. After 2 months SD-OCT revealed a small defect of the ellipsoid zone. In one patient the defect could not be shown due to slightly excentric imaging sections. Best corrected visual acuity increased to 0.97. The SD-OCT is an appropriate tool to determine the exact localization of the site of damage and for follow-up examination in solar retinopathy. In the acute phase it shows a disruption of the continuity of all layers in the foveola. Despite good recovery of visual acuity a small central defect of the ellipsoid zone remains in the long term.

  3. Method and apparatus for inspecting reflection masks for defects

    DOEpatents

    Bokor, Jeffrey; Lin, Yun

    2003-04-29

    An at-wavelength system for extreme ultraviolet lithography mask blank defect detection is provided. When a focused beam of wavelength 13 nm is incident on a defective region of a mask blank, three possible phenomena can occur. The defect will induce an intensity reduction in the specularly reflected beam, scatter incoming photons into an off-specular direction, and change the amplitude and phase of the electric field at the surface which can be monitored through the change in the photoemission current. The magnitude of these changes will depend on the incident beam size, and the nature, extent and size of the defect. Inspection of the mask blank is performed by scanning the mask blank with 13 nm light focused to a spot a few .mu.m in diameter, while measuring the reflected beam intensity (bright field detection), the scattered beam intensity (dark-field detection) and/or the change in the photoemission current.

  4. Surface defects evaluation system based on electromagnetic model simulation and inverse-recognition calibration method

    NASA Astrophysics Data System (ADS)

    Yang, Yongying; Chai, Huiting; Li, Chen; Zhang, Yihui; Wu, Fan; Bai, Jian; Shen, Yibing

    2017-05-01

    Digitized evaluation of micro sparse defects on large fine optical surfaces is one of the challenges in the field of optical manufacturing and inspection. The surface defects evaluation system (SDES) for large fine optical surfaces is developed based on our previously reported work. In this paper, the electromagnetic simulation model based on Finite-Difference Time-Domain (FDTD) for vector diffraction theory is firstly established to study the law of microscopic scattering dark-field imaging. Given the aberration in actual optical systems, point spread function (PSF) approximated by a Gaussian function is introduced in the extrapolation from the near field to the far field and the scatter intensity distribution in the image plane is deduced. Analysis shows that both diffraction-broadening imaging and geometrical imaging should be considered in precise size evaluation of defects. Thus, a novel inverse-recognition calibration method is put forward to avoid confusion caused by diffraction-broadening effect. The evaluation method is applied to quantitative evaluation of defects information. The evaluation results of samples of many materials by SDES are compared with those by OLYMPUS microscope to verify the micron-scale resolution and precision. The established system has been applied to inspect defects on large fine optical surfaces and can achieve defects inspection of surfaces as large as 850 mm×500 mm with the resolution of 0.5 μm.

  5. Finite element approximation of the fields of bulk and interfacial line defects

    NASA Astrophysics Data System (ADS)

    Zhang, Chiqun; Acharya, Amit; Puri, Saurabh

    2018-05-01

    A generalized disclination (g.disclination) theory (Acharya and Fressengeas, 2015) has been recently introduced that goes beyond treating standard translational and rotational Volterra defects in a continuously distributed defects approach; it is capable of treating the kinematics and dynamics of terminating lines of elastic strain and rotation discontinuities. In this work, a numerical method is developed to solve for the stress and distortion fields of g.disclination systems. Problems of small and finite deformation theory are considered. The fields of a single disclination, a single dislocation treated as a disclination dipole, a tilt grain boundary, a misfitting grain boundary with disconnections, a through twin boundary, a terminating twin boundary, a through grain boundary, a star disclination/penta-twin, a disclination loop (with twist and wedge segments), and a plate, a lenticular, and a needle inclusion are approximated. It is demonstrated that while the far-field topological identity of a dislocation of appropriate strength and a disclination-dipole plus a slip dislocation comprising a disconnection are the same, the latter microstructure is energetically favorable. This underscores the complementary importance of all of topology, geometry, and energetics in understanding defect mechanics. It is established that finite element approximations of fields of interfacial and bulk line defects can be achieved in a systematic and routine manner, thus contributing to the study of intricate defect microstructures in the scientific understanding and predictive design of materials. Our work also represents one systematic way of studying the interaction of (g.)disclinations and dislocations as topological defects, a subject of considerable subtlety and conceptual importance (Aharoni et al., 2017; Mermin, 1979).

  6. Birth Defects. Matrix No. 2.

    ERIC Educational Resources Information Center

    Brent, Robert L.

    This report discusses the magnitude of the problem of birth defects, outlines advances in the birth defects field in the past decade, and identifies those areas where research is needed for the prevention, treatment, and management of birth defects. The problem of birth defects has consumed a greater portion of our health care resources because of…

  7. Visual Field Abnormalities among Adolescent Boys with Hearing Impairments

    PubMed Central

    KHORRAMI-NEJAD, Masoud; HERAVIAN, Javad; SEDAGHAT, Mohamad-Reza; MOMENI-MOGHADAM, Hamed; SOBHANI-RAD, Davood; ASKARIZADEH, Farshad

    2016-01-01

    The aim of this study was to compare the visual field (VF) categorizations (based on the severity of VF defects) between adolescent boys with hearing impairments and those with normal hearing. This cross-sectional study involved the evaluation of the VF of 64 adolescent boys with hearing impairments and 68 age-matched boys with normal hearing at high schools in Tehran, Iran, in 2013. All subjects had an intelligence quotient (IQ) > 70. The hearing impairments were classified based on severity and time of onset. Participants underwent a complete eye examination, and the VFs were investigated using automated perimetry with a Humphrey Visual Field Analyzer. This device was used to determine their foveal threshold (FT), mean deviation (MD), and Glaucoma Hemifield Test (GHT) results. Most (50%) of the boys with hearing impairments had profound hearing impairments. There was no significant between-group difference in age (P = 0.49) or IQ (P = 0.13). There was no between-group difference in the corrected distance visual acuity (P = 0.183). According to the FT, MD, and GHT results, the percentage of boys with abnormal VFs in the hearing impairment group was significantly greater than that in the normal hearing group: 40.6% vs. 22.1%, 59.4% vs. 19.1%, and 31.2% vs. 8.8%, respectively (P < 0.0001). The mean MD in the hearing impairment group was significantly worse than that in the normal hearing group (-0.79 ± 2.04 and -4.61 ± 6.52 dB, respectively, P < 0.0001), and the mean FT was also significantly worse (38.97 ± 1.66 vs. 35.30 ± 1.43 dB, respectively, P <0.0001). Moreover, there was a significant between-group difference in the GHT results (P < 0.0001). Thus, there were higher percentages of boys with VF abnormalities and higher mean MD, FT, and GHT results among those with hearing impairments compared to those with normal hearing. These findings emphasize the need for detailed VF assessments for patients with hearing impairments. PMID:28293650

  8. Discriminant Analysis of Defective and Non-Defective Field Pea (Pisum sativum L.) into Broad Market Grades Based on Digital Image Features.

    PubMed

    McDonald, Linda S; Panozzo, Joseph F; Salisbury, Phillip A; Ford, Rebecca

    2016-01-01

    Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective.

  9. Discriminant Analysis of Defective and Non-Defective Field Pea (Pisum sativum L.) into Broad Market Grades Based on Digital Image Features

    PubMed Central

    McDonald, Linda S.; Panozzo, Joseph F.; Salisbury, Phillip A.; Ford, Rebecca

    2016-01-01

    Field peas (Pisum sativum L.) are generally traded based on seed appearance, which subjectively defines broad market-grades. In this study, we developed an objective Linear Discriminant Analysis (LDA) model to classify market grades of field peas based on seed colour, shape and size traits extracted from digital images. Seeds were imaged in a high-throughput system consisting of a camera and laser positioned over a conveyor belt. Six colour intensity digital images were captured (under 405, 470, 530, 590, 660 and 850nm light) for each seed, and surface height was measured at each pixel by laser. Colour, shape and size traits were compiled across all seed in each sample to determine the median trait values. Defective and non-defective seed samples were used to calibrate and validate the model. Colour components were sufficient to correctly classify all non-defective seed samples into correct market grades. Defective samples required a combination of colour, shape and size traits to achieve 87% and 77% accuracy in market grade classification of calibration and validation sample-sets respectively. Following these results, we used the same colour, shape and size traits to develop an LDA model which correctly classified over 97% of all validation samples as defective or non-defective. PMID:27176469

  10. Clinical profile and aetiology of optic neuritis in Hospital Universiti Sains Malaysia--5 years review.

    PubMed

    Ismail, Shatriah; Wan Hazabbah, Wan Hitam; Muhd-Nor, Nor-Idahriani; Daud, Jakiyah; Embong, Zunaina

    2012-04-01

    Although few studies concerning optic neuritis (ON) in Asian countries have been reported, there is no report about ON in Malaysia particularly within the Malay population. We aimed to determine the clinical manifestation, visual outcome and aetiology of ON in Malays, and discussed the literature of ON studies in other Asian populations. This was a retrospective study involving 31 consecutive patients (41 eyes) with ON treated at Hospital Universiti Sains Malaysia commencing from July 2005 till January 2010 with a period of follow-up ranging from 18-60 months. The clinical features, laboratory results, possible aetiology, and visual acuity after one year were analysed. Females were the predominant group. The age of the patients ranged between 3-55 years and peaked between 21-30 years old. 67.7% of the patients had unilateral involvement. Pain on ocular movement was observed in 31.7% of the affected eyes. 73.3% of 41 involved eyes showed visual acuity equal 6/60 or worse on presentation. Paracentral scotoma was the most common visual field defect noted. Optic disc papillitis proved more widespread compared to the retrobulbar type of ON. The aetiology was idiopathic in more than 50%, while the risk of multiple sclerosis was extremely low (3.2%) in our series. 66.0% demonstrating visual acuity improved to 6/12 or better at one year after the attack. 16.1% showed evidence of recurrence during follow-up. In conclusion, the clinical profile and aetiology of ON in Malay patients are comparable to other ON studies reported by other Asian countries.

  11. The Advanced Glaucoma Intervention Study (AGIS): 4. Comparison of treatment outcomes within race. Seven-year results.

    PubMed

    1998-07-01

    The purpose of this report is to present separately for black and white patients with advanced glaucoma 7-year results of two alternative surgical intervention sequences. A randomized controlled trial. A total of 332 black patients (451 eyes), 249 white patients (325 eyes), and 10 patients of other races (13 eyes) participated. Potential follow-up ranged from 4 to 7 years. Eyes were randomly assigned to either an argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy (ATT) sequence or a trabeculectomy-ALT-trabeculectomy (TAT) sequence. The second and third interventions were offered after failure of the first and second interventions, respectively. Average percent of eyes with decrease of visual field (APDVF), average percent of eyes with decrease of visual acuity (APDVA), and average percent of eyes with decrease of vision (APDV) are the outcome measures. Decrease of visual field (DVF) is an increase from baseline of at least 4 points on a glaucoma visual field defect scale ranging from 0 to 20, decrease of visual acuity (DVA) is a decrease from baseline of at least 15 letters (3 lines), and decrease of vision (DV) is the occurrence of either DVF or DVA. The averages are of percent decreases observed at 6-month intervals from the first 6-month visit to the end of the specified observation period. In both black and white patients throughout 7-year follow-up, the mean decrease in intraocular pressure was greater in eyes assigned to TAT, and the cumulative probability of failure of the first intervention was greater in eyes assigned to ATT. In black patients, APDVF, APDVA, and APDV are less for the ATT sequence than for the TAT sequence throughout the 7 years. In white patients, APDVF also favors the ATT sequence but only for the first year, after which it favors the TAT sequence through the seventh year; APDVA also favors the ATT sequence, but the ATT-TAT difference progressively diminishes over 7 years; and APDV favors ATT over TAT initially, but after 4 years, the advantage switches to and remains with TAT. These data support use of the ATT sequence for all black patients. For white patients without life-threatening health problems, the data support use of the TAT sequence.

  12. Evaluation of nondestructive testing techniques for the space shuttle nonmetallic thermal protection system

    NASA Technical Reports Server (NTRS)

    Tiede, D. A.

    1972-01-01

    A program was conducted to evaluate nondestructive analysis techniques for the detection of defects in rigidized surface insulation (a candidate material for the Space Shuttle thermal protection system). Uncoated, coated, and coated and bonded samples with internal defects (voids, cracks, delaminations, density variations, and moisture content), coating defects (holes, cracks, thickness variations, and loss of adhesion), and bondline defects (voids and unbonds) were inspected by X-ray radiography, acoustic, microwave, high-frequency ultrasonic, beta backscatter, thermal, holographic, and visual techniques. The detectability of each type of defect was determined for each technique (when applicable). A possible relationship between microwave reflection measurements (or X-ray-radiography density measurements) and the tensile strength was established. A possible approach for in-process inspection using a combination of X-ray radiography, acoustic, microwave, and holographic techniques was recommended.

  13. Microstructure of the optic disc pit in open-angle glaucoma.

    PubMed

    Choi, Yun Jeong; Lee, Eun Ji; Kim, Bo Hyuk; Kim, Tae-Woo

    2014-11-01

    To investigate the structural and clinical characteristics of the optic disc pit (ODP) in primary open-angle glaucoma (POAG) via enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). Prospective, observational case series. Seventy POAG eyes clinically diagnosed with an ODP via stereo disc photography. Optic discs were scanned using EDI SD-OCT. Serial horizontal and vertical B-scan images covering the optic discs were obtained from each eye. The structural characteristics of the ODP were investigated via 3-dimensional images constructed from the serial B-scans, focusing on the presence of alterations in the contour of the lamina cribrosa (LC) or prelaminar tissue (PLT), in conjunction with associated clinical characteristics. The structural characteristics of the ODP and associated clinical characteristics. In the EDI SD-OCT images, the ODP was viewed as an isolated alteration of the LC (n = 14, 20.0%) or PLT (n = 16, 22.9%) or an alteration of both the LC and PLT (n = 40, 57.1%). Alterations of the LC were located at the mid-periphery near the LC insertion (n = 17) or far periphery adjacent to the LC insertion (n = 37), and the depth of alteration was deep (n = 23), involving nearly full-thickness LC, or shallow (n = 31), with partially visible LC at the base. Fifty-four eyes (77.1%) exhibited parafoveal visual field (VF) defect within 10 degrees of fixation, and in 98.1% of these eyes (53/54) it was spatially associated with the location of ODP. The parafoveal VF defect was more prevalent in eyes with LC alteration than those without (83.3% vs. 56.2%, P = 0.023) and in eyes with deep LC defect than those with shallow defect (95.7% vs. 74.2%, P = 0.036). Disc hemorrhage (32.4% vs. 0.0%, P = 0.008) and peripapillary retinoschisis (18.9 vs. 0.0%, P = 0.055) were more strongly associated with LC alterations located at the far periphery than at the mid-periphery. Enhanced depth imaging SD-OCT facilitated visualization of the varied structure of the ODP, which presented as alteration of the LC or PLT or both. The clinical significance of differing characteristics of ODP microstructure remains to be determined. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Modeling a distribution of point defects as misfitting inclusions in stressed solids

    NASA Astrophysics Data System (ADS)

    Cai, W.; Sills, R. B.; Barnett, D. M.; Nix, W. D.

    2014-05-01

    The chemical equilibrium distribution of point defects modeled as non-overlapping, spherical inclusions with purely positive dilatational eigenstrain in an isotropically elastic solid is derived. The compressive self-stress inside existing inclusions must be excluded from the stress dependence of the equilibrium concentration of the point defects, because it does no work when a new inclusion is introduced. On the other hand, a tensile image stress field must be included to satisfy the boundary conditions in a finite solid. Through the image stress, existing inclusions promote the introduction of additional inclusions. This is contrary to the prevailing approach in the literature in which the equilibrium point defect concentration depends on a homogenized stress field that includes the compressive self-stress. The shear stress field generated by the equilibrium distribution of such inclusions is proved to be proportional to the pre-existing stress field in the solid, provided that the magnitude of the latter is small, so that a solid containing an equilibrium concentration of point defects can be described by a set of effective elastic constants in the small-stress limit.

  15. Phase time delay and Hartman effect in a one-dimensional photonic crystal with four-level atomic defect layer

    NASA Astrophysics Data System (ADS)

    Jamil, Rabia; Ali, Abu Bakar; Abbas, Muqaddar; Badshah, Fazal; Qamar, Sajid

    2017-08-01

    The Hartman effect is revisited using a Gaussian beam incident on a one-dimensional photonic crystal (1DPC) having a defect layer doped with four-level atoms. It is considered that each atom of the defect layer interacts with three driving fields, whereas a Gaussian beam of width w is used as a probe light to study Hartman effect. The atom-field interaction inside the defect layer exhibits electromagnetically induced transparency (EIT). The 1DPC acts as positive index material (PIM) and negative index material (NIM) corresponding to the normal and anomalous dispersion of the defect layer, respectively, via control of the phase associated with the driving fields and probe detuning. The positive and negative Hartman effects are noticed for PIM and NIM, respectively, via control of the relative phase corresponding to the driving fields and probe detuning. The advantage of using four-level EIT system is that a much smaller absorption of the transmitted beam occurs as compared to three-level EIT system corresponding to the anomalous dispersion, leading to negative Hartman effect.

  16. Human vision-based algorithm to hide defective pixels in LCDs

    NASA Astrophysics Data System (ADS)

    Kimpe, Tom; Coulier, Stefaan; Van Hoey, Gert

    2006-02-01

    Producing displays without pixel defects or repairing defective pixels is technically not possible at this moment. This paper presents a new approach to solve this problem: defects are made invisible for the user by using image processing algorithms based on characteristics of the human eye. The performance of this new algorithm has been evaluated using two different methods. First of all the theoretical response of the human eye was analyzed on a series of images and this before and after applying the defective pixel compensation algorithm. These results show that indeed it is possible to mask a defective pixel. A second method was to perform a psycho-visual test where users were asked whether or not a defective pixel could be perceived. The results of these user tests also confirm the value of the new algorithm. Our "defective pixel correction" algorithm can be implemented very efficiently and cost-effectively as pixel-dataprocessing algorithms inside the display in for instance an FPGA, a DSP or a microprocessor. The described techniques are also valid for both monochrome and color displays ranging from high-quality medical displays to consumer LCDTV applications.

  17. Analysis, Simulation and Prediction of Cosmetic Defects on Automotive External Panel

    NASA Astrophysics Data System (ADS)

    Le Port, A.; Thuillier, S.; Borot, C.; Charbonneaux, J.

    2011-08-01

    The first feeling of quality for a vehicle is linked to its perfect appearance. This has a major impact on the reputation of a car manufacturer. Cosmetic defects are thus more and more taken into account in the process design. Qualifying a part as good or bad from the cosmetic point of view is mainly subjective: the part aspect is considered acceptable if no defect is visible on the vehicle by the final customer. Cosmetic defects that appear during sheet metal forming are checked by visual inspection in light inspection rooms, stoning, or with optical or mechanical sensors or feelers. A lack of cosmetic defect prediction before part production leads to the need for corrective actions, production delays and generates additional costs. This paper first explores the objective description of what cosmetic defects are on a stamped part and where they come from. It then investigates the capability of software to predict these defects, and suggests the use of a cosmetic defects analysis tool developed within PAM-STAMP 2G for its qualitative and quantitative prediction.

  18. Long-term effect of latanoprost/timolol fixed combination in patients with glaucoma or ocular hypertension: A prospective, observational, noninterventional study

    PubMed Central

    2010-01-01

    Background Prospective, observational studies that enroll large numbers of patients with few exclusion criteria may better reflect actual ongoing clinical experience than randomized clinical trials. Our purpose was to obtain efficacy and safety information from a cohort of subjects exposed to latanoprost/timolol fixed combination (FC) for ≥18 months using a prospective, observational design. Methods In all, 577 office-based ophthalmologists in Germany switched 2339 patients with glaucoma or ocular hypertension to latanoprost/timolol FC for medical reasons. Follow-up visits were scheduled for every 6 months over 24 months; physicians followed usual care routines. Intraocular pressure (IOP), visual field status, optic nerve head findings, and adverse events were recorded. Efficacy parameters were evaluated for the per protocol (PP) population; the safety population included subjects receiving ≥1 drop of FC. Physicians rated efficacy, tolerability, and subject compliance at month 24. Results Of the 2339 subjects switched to latanoprost/timolol FC (safety population), the primary reasons for switching were inadequate IOP reduction (78.2%) and desire to simplify treatment with once-daily dosing (29.4%; multiple reasons possible). In all, 1317 (56.3%) subjects completed the study, and 1028 (44.0%) were included in the PP population. Most discontinuations were due to loss to follow-up. Change in mean IOP from baseline to month 6 was -4.0 ± 4.31 mmHg, a reduction that was maintained throughout (P < 0.05 for change at all time points). By investigator assessments, optic disc parameters and visual field were stable over 24 months, and there was no relationship between IOP reduction over 24 months and development of a visual field defect. More than 90% of physicians rated latanoprost/timolol FC as "very good" or "good" for efficacy (PP population), tolerability, and compliance. The FC was safe and well tolerated. No change in iris color was reported by most subjects (83.1%) at month 24. Conclusions Over 24 months, latanoprost/timolol FC effectively lowers IOP levels and is well tolerated in patients with glaucoma or ocular hypertension who change from their previous ocular hypotensive therapy for medical reasons. Investigator assessments found optic disc parameters and visual field to be stable throughout 24 months of follow-up. PMID:20825668

  19. Structural and functional correlates of visual field asymmetry in the human brain by diffusion kurtosis MRI and functional MRI.

    PubMed

    O'Connell, Caitlin; Ho, Leon C; Murphy, Matthew C; Conner, Ian P; Wollstein, Gadi; Cham, Rakie; Chan, Kevin C

    2016-11-09

    Human visual performance has been observed to show superiority in localized regions of the visual field across many classes of stimuli. However, the underlying neural mechanisms remain unclear. This study aims to determine whether the visual information processing in the human brain is dependent on the location of stimuli in the visual field and the corresponding neuroarchitecture using blood-oxygenation-level-dependent functional MRI (fMRI) and diffusion kurtosis MRI, respectively, in 15 healthy individuals at 3 T. In fMRI, visual stimulation to the lower hemifield showed stronger brain responses and larger brain activation volumes than the upper hemifield, indicative of the differential sensitivity of the human brain across the visual field. In diffusion kurtosis MRI, the brain regions mapping to the lower visual field showed higher mean kurtosis, but not fractional anisotropy or mean diffusivity compared with the upper visual field. These results suggested the different distributions of microstructural organization across visual field brain representations. There was also a strong positive relationship between diffusion kurtosis and fMRI responses in the lower field brain representations. In summary, this study suggested the structural and functional brain involvements in the asymmetry of visual field responses in humans, and is important to the neurophysiological and psychological understanding of human visual information processing.

  20. Functional visual fields: relationship of visual field areas to self-reported function.

    PubMed

    Subhi, Hikmat; Latham, Keziah; Myint, Joy; Crossland, Michael D

    2017-07-01

    The aim of this study is to relate areas of the visual field to functional difficulties to inform the development of a binocular visual field assessment that can reflect the functional consequences of visual field loss. Fifty-two participants with peripheral visual field loss undertook binocular assessment of visual fields using the 30-2 and 60-4 SITA Fast programs on the Humphrey Field Analyser, and mean thresholds were derived. Binocular visual acuity, contrast sensitivity and near reading performance were also determined. Self-reported overall and mobility function were assessed using the Dutch ICF Activity Inventory. Greater visual field loss (0-60°) was associated with worse self-reported function both overall (R 2 = 0.50; p < 0.0001), and for mobility (R 2 = 0.64; p < 0.0001). Central (0-30°) and peripheral (30-60°) visual field areas were similarly related to mobility function (R 2 = 0.61, p < 0.0001 and R 2 = 0.63, p < 0.0001 respectively), although the peripheral (30-60°) visual field was the best predictor of mobility self-reported function in multiple regression analyses. Superior and inferior visual field areas related similarly to mobility function (R 2 = 0.56, p < 0.0001 and R 2 = 0.67, p < 0.0001 respectively). The inferior field was found to be the best predictor of mobility function in multiple regression analysis. Mean threshold of the binocular visual field to 60° eccentricity is a good predictor of self-reported function overall, and particularly of mobility function. Both the central (0-30°) and peripheral (30-60°) mean threshold are good predictors of self-reported function, but the peripheral (30-0°) field is a slightly better predictor of mobility function, and should not be ignored when considering functional consequences of field loss. The inferior visual field is a slightly stronger predictor of perceived overall and mobility function than the superior field. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

Top