The four-meter confrontation visual field test.
Kodsi, S R; Younge, B R
1992-01-01
The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests. PMID:1494829
The four-meter confrontation visual field test.
Kodsi, S R; Younge, B R
1992-01-01
The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests.
Automated objective characterization of visual field defects in 3D
NASA Technical Reports Server (NTRS)
Fink, Wolfgang (Inventor)
2006-01-01
A method and apparatus for electronically performing a visual field test for a patient. A visual field test pattern is displayed to the patient on an electronic display device and the patient's responses to the visual field test pattern are recorded. A visual field representation is generated from the patient's responses. The visual field representation is then used as an input into a variety of automated diagnostic processes. In one process, the visual field representation is used to generate a statistical description of the rapidity of change of a patient's visual field at the boundary of a visual field defect. In another process, the area of a visual field defect is calculated using the visual field representation. In another process, the visual field representation is used to generate a statistical description of the volume of a patient's visual field defect.
The accuracy of confrontation visual field test in comparison with automated perimetry.
Johnson, L. N.; Baloh, F. G.
1991-01-01
The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764
Red square test for visual field screening. A sensitive and simple bedside test.
Mandahl, A
1994-12-01
A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and
Early detection of glaucoma by means of a novel 3D computer‐automated visual field test
Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald
2007-01-01
Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma. PMID:17504855
Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
Rowe, Fiona J.; Rowlands, Alison
2014-01-01
Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983
Nesaratnam, Nisha; Thomas, Peter B M; Kirollos, Ramez; Vingrys, Algis J; Kong, George Y X; Martin, Keith R
2017-04-24
In the assessment of a pituitary mass, objective visual field testing represents a valuable means of evaluating mass effect, and thus in deciding whether surgical management is warranted. In this vignette, we describe a 73 year-old lady who presented with a three-week history of frontal headache, and 'blurriness' in the left side of her vision, due to a WHO grade III anaplastic haemangiopericytoma compressing the optic chiasm. We report how timely investigations, including an iPad-based visual field test (Melbourne Rapid Field, (MRF)) conducted at the bedside aided swift and appropriate management of the patient. We envisage such a test having a role in assessing bed-bound patients in hospital where access to formal visual field testing is difficult, or indeed in rapid testing of visual fields at the bedside to screen for post-operative complications, such as haematoma.
Normal Threshold Size of Stimuli in Children Using a Game-Based Visual Field Test.
Wang, Yanfang; Ali, Zaria; Subramani, Siddharth; Biswas, Susmito; Fenerty, Cecilia; Henson, David B; Aslam, Tariq
2017-06-01
The aim of this study was to demonstrate and explore the ability of novel game-based perimetry to establish normal visual field thresholds in children. One hundred and eighteen children (aged 8.0 ± 2.8 years old) with no history of visual field loss or significant medical history were recruited. Each child had one eye tested using a game-based visual field test 'Caspar's Castle' at four retinal locations 12.7° (N = 118) from fixation. Thresholds were established repeatedly using up/down staircase algorithms with stimuli of varying diameter (luminance 20 cd/m 2 , duration 200 ms, background luminance 10 cd/m 2 ). Relationships between threshold and age were determined along with measures of intra- and intersubject variability. The Game-based visual field test was able to establish threshold estimates in the full range of children tested. Threshold size reduced with increasing age in children. Intrasubject variability and intersubject variability were inversely related to age in children. Normal visual field thresholds were established for specific locations in children using a novel game-based visual field test. These could be used as a foundation for developing a game-based perimetry screening test for children.
... shade or curtain hanging across part of your visual field. Optic neuritis : inflammation of the optic nerve ... to ask your doctor Images Crossed eyes Eye Visual acuity test Slit-lamp exam Visual field test ...
Visual field progression in glaucoma: total versus pattern deviation analyses.
Artes, Paul H; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C
2005-12-01
To compare visual field progression with total and pattern deviation analyses in a prospective longitudinal study of patients with glaucoma and healthy control subjects. A group of 101 patients with glaucoma (168 eyes) with early to moderately advanced visual field loss at baseline (average mean deviation [MD], -3.9 dB) and no clinical evidence of media opacity were selected from a prospective longitudinal study on visual field progression in glaucoma. Patients were examined with static automated perimetry at 6-month intervals for a median follow-up of 9 years. At each test location, change was established with event and trend analyses of total and pattern deviation. The event analyses compared each follow-up test to a baseline obtained from averaging the first two tests, and visual field progression was defined as deterioration beyond the 5th percentile of test-retest variability at three test locations, observed on three consecutive tests. The trend analyses were based on point-wise linear regression, and visual field progression was defined as statistically significant deterioration (P < 5%) worse than -1 dB/year at three locations, confirmed by independently omitting the last and the penultimate observation. The incidence and the time-to-progression were compared between total and pattern deviation analyses. To estimate the specificity of the progression analyses, identical criteria were applied to visual fields obtained in 102 healthy control subjects, and the rate of visual field improvement was established in the patients with glaucoma and the healthy control subjects. With both event and trend methods, pattern deviation analyses classified approximately 15% fewer eyes as having progressed than did the total deviation analyses. In eyes classified as progressing by both the total and pattern deviation methods, total deviation analyses tended to detect progression earlier than the pattern deviation analyses. A comparison of the changes observed in MD and the visual fields' general height (estimated by the 85th percentile of the total deviation values) confirmed that change in the glaucomatous eyes almost always comprised a diffuse component. Pattern deviation analyses of progression may therefore underestimate the true amount of glaucomatous visual field progression. Pattern deviation analyses of visual field progression may underestimate visual field progression in glaucoma, particularly when there is no clinical evidence of increasing media opacity. Clinicians should have access to both total and pattern deviation analyses to make informed decisions on visual field progression in glaucoma.
Vision-related fitness to drive mobility scooters: A practical driving test.
Cordes, Christina; Heutink, Joost; Tucha, Oliver M; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M
2017-03-06
To investigate practical fitness to drive mobility scooters, comparing visually impaired participants with healthy controls. Between-subjects design. Forty-six visually impaired (13 with very low visual acuity, 10 with low visual acuity, 11 with peripheral field defects, 12 with multiple visual impairment) and 35 normal-sighted controls. Participants completed a practical mobility scooter test-drive, which was recorded on video. Two independent occupational therapists specialized in orientation and mobility evaluated the videos systematically. Approximately 90% of the visually impaired participants passed the driving test. On average, participants with visual impairments performed worse than normal-sighted controls, but were judged sufficiently safe. In particular, difficulties were observed in participants with peripheral visual field defects and those with a combination of low visual acuity and visual field defects. People with visual impairment are, in practice, fit to drive mobility scooters; thus visual impairment on its own should not be viewed as a determinant of safety to drive mobility scooters. However, special attention should be paid to individuals with visual field defects with or without a combined low visual acuity. The use of an individual practical fitness-to-drive test is advised.
Sunglasses with thick temples and frame constrict temporal visual field.
Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric
2013-12-01
Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.
Visual field defects may not affect safe driving.
Dow, Jamie
2011-10-01
In Quebec a driver whose acquired visual field defect renders them ineligible for a driver's permit renewal may request an exemption from the visual field standard by demonstrating safe driving despite the defect. For safety reasons it was decided to attempt to identify predictors of failure on the road test in order to avoid placing driving evaluators in potentially dangerous situations when evaluating drivers with visual field defects. During a 4-month period in 2009 all requests for exemptions from the visual field standard were collected and analyzed. All available medical and visual field data were collated for 103 individuals, of whom 91 successfully completed the evaluation process and obtained a waiver. The collated data included age, sex, type of visual field defect, visual field characteristics, and concomitant medical problems. No single factor, or combination of factors, could predict failure of the road test. All 5 failures of the road test had cognitive problems but 6 of the successful drivers also had known cognitive problems. Thus, cognitive problems influence the risk of failure but do not predict certain failure. Most of the applicants for an exemption were able to complete the evaluation process successfully, thereby demonstrating safe driving despite their handicap. Consequently, jurisdictions that have visual field standards for their driving permit should implement procedures to evaluate drivers with visual field defects that render them unable to meet the standard but who wish to continue driving.
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.
Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios
2017-01-01
To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
Specvis: Free and open-source software for visual field examination.
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna; Waleszczyk, Wioletta J
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions).
Specvis: Free and open-source software for visual field examination
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions). PMID:29028825
Ramirez, Adriana M; Chaya, Craig J; Gordon, Lynn K; Giaconi, Joann A
2008-03-01
To determine if semiautomated kinetic perimetry (SKP) is reproducible and comparable to Goldmann manual kinetic perimetry (GVF). Glaucoma patients were recruited to perform visual field testing using GVF and SKP. Specific isopters were tested, quantified, and compared. Visual field patterns were analyzed for shape and defect. Ten patients (16 eyes) underwent visual field studies using SKP and GVF, and 8 patients completed a second SKP on a different day. Individual isopter areas were similar between GVF and SKP, although 60% of isopters were larger on SKP by an average of 15%. This was statistically significant for the smaller isopters, I4e (P=0.02) and I2e (P=0.05). Retesting with SKP on a separate day, showed similar isopter areas (P values=0.3 to 1.0), however, the exact location of isopters in degrees from central fixation tended to vary with the smaller test object sizes. Isopter position in degrees from the central axis agreed in at least 3 quadrants in approximately 65% of fields compared. SKP visual field defects and patterns were similar between test strategies. SKP and GVF testing produce similar visual field results in glaucoma patients, and SKP testing seems to be reliable and reproducible in this population. However, overlapping isopters, typically associated with nonorganic vision loss, and jagged isopters were sometimes observed in SKP visual fields. Further study of SKP is needed to explore these findings.
Effect of a patient training video on visual field test reliability
Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P
2003-01-01
Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740
Effect of a patient training video on visual field test reliability.
Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P
2003-02-01
To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarize them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye.
Effect of Cognitive Demand on Functional Visual Field Performance in Senior Drivers with Glaucoma.
Gangeddula, Viswa; Ranchet, Maud; Akinwuntan, Abiodun E; Bollinger, Kathryn; Devos, Hannes
2017-01-01
Purpose: To investigate the effect of cognitive demand on functional visual field performance in drivers with glaucoma. Method: This study included 20 drivers with open-angle glaucoma and 13 age- and sex-matched controls. Visual field performance was evaluated under different degrees of cognitive demand: a static visual field condition (C1), dynamic visual field condition (C2), and dynamic visual field condition with active driving (C3) using an interactive, desktop driving simulator. The number of correct responses (accuracy) and response times on the visual field task were compared between groups and between conditions using Kruskal-Wallis tests. General linear models were employed to compare cognitive workload, recorded in real-time through pupillometry, between groups and conditions. Results: Adding cognitive demand (C2 and C3) to the static visual field test (C1) adversely affected accuracy and response times, in both groups ( p < 0.05). However, drivers with glaucoma performed worse than did control drivers when the static condition changed to a dynamic condition [C2 vs. C1 accuracy; glaucoma: median difference (Q1-Q3) 3 (2-6.50) vs. 2 (0.50-2.50); p = 0.05] and to a dynamic condition with active driving [C3 vs. C1 accuracy; glaucoma: 2 (2-6) vs. 1 (0.50-2); p = 0.02]. Overall, drivers with glaucoma exhibited greater cognitive workload than controls ( p = 0.02). Conclusion: Cognitive demand disproportionately affects functional visual field performance in drivers with glaucoma. Our results may inform the development of a performance-based visual field test for drivers with glaucoma.
Testing of visual field with virtual reality goggles in manual and visual grasp modes.
Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.
Tailor, Vijay; Glaze, Selina; Unwin, Hilary; Bowman, Richard; Thompson, Graham; Dahlmann-Noor, Annegret
2016-10-01
Children and adults with neurological impairments are often not able to access conventional perimetry; however, information about the visual field is valuable. A new technology, saccadic vector optokinetic perimetry (SVOP), may have improved accessibility, but its accuracy has not been evaluated. We aimed to explore accessibility, testability and accuracy of SVOP in children with neurodisability or isolated visual pathway deficits. Cohort study; recruitment October 2013-May 2014, at children's eye clinics at a tertiary referral centre and a regional Child Development Centre; full orthoptic assessment, SVOP (central 30° of the visual field) and confrontation visual fields (CVF). Group 1: age 1-16 years, neurodisability (n=16), group 2: age 10-16 years, confirmed or suspected visual field defect (n=21); group 2 also completed Goldmann visual field testing (GVFT). Group 1: testability with a full 40-point test protocol is 12.5%; with reduced test protocols, testability is 100%, but plots may be clinically meaningless. Children (44%) and parents/carers (62.5%) find the test easy. SVOP and CVF agree in 50%. Group 2: testability is 62% for the 40-point protocol, and 90.5% for reduced protocols. Corneal changes in childhood glaucoma interfere with SVOP testing. All children and parents/carers find SVOP easy. Overall agreement with GVFT is 64.7%. While SVOP is highly accessible to children, many cannot complete a full 40-point test. Agreement with current standard tests is moderate to poor. Abnormal saccades cause an apparent non-specific visual field defect. In children with glaucoma or nystagmus SVOP calibration often fails. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari
2014-02-01
Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.
Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima
2014-01-01
Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212
'I didn't see that coming': simulated visual fields and driving hazard perception test performance.
Glen, Fiona C; Smith, Nicholas D; Jones, Lee; Crabb, David P
2016-09-01
Evidence is limited regarding specific types of visual field loss associated with unsafe driving. We use novel gaze-contingent software to examine the effect of simulated visual field loss on computer-based driving hazard detection with the specific aim of testing the impact of scotomata located to the right and left of fixation. The 'hazard perception test' is a component of the UK driving licence examination, which measures speed of detecting 15 different hazards in a series of real-life driving films. We have developed a novel eye-tracking and computer set up capable of generating a realistic gaze-contingent scotoma simulation (GazeSS) overlaid on film content. Thirty drivers with healthy vision completed three versions of the hazard perception test in a repeated measures experiment. In two versions, GazeSS simulated a scotoma in the binocular field of view to the left or right of fixation. A third version was unmodified to establish baseline performance. Participants' mean baseline hazard perception test score was 51 ± 7 (out of 75). This reduced to 46 ± 9 and 46 ± 11 when completing the task with a binocular visual field defect located to the left and right of fixation, respectively. While the main effect of simulated visual field loss on performance was statistically significant (p = 0.007), there were no average differences in the experimental conditions where a scotoma was located in the binocular visual field to the right or left of fixation. Simulated visual field loss impairs driving hazard detection on a computer-based test. There was no statistically significant difference in average performance when the simulated scotoma was located to the right or left of fixation of the binocular visual field, but certain types of hazard caused more difficulties than others. © 2016 Optometry Australia.
Wood, Joanne M; Owsley, Cynthia
2014-01-01
The useful field of view test was developed to reflect the visual difficulties that older adults experience with everyday tasks. Importantly, the useful field of view test (UFOV) is one of the most extensively researched and promising predictor tests for a range of driving outcomes measures, including driving ability and crash risk as well as other everyday tasks. Currently available commercial versions of the test can be administered using personal computers; these measure the speed of visual processing for rapid detection and localization of targets under conditions of divided visual attention and in the presence and absence of visual clutter. The test is believed to assess higher-order cognitive abilities, but performance also relies on visual sensory function because in order for targets to be attended to, they must be visible. The format of the UFOV has been modified over the years; the original version estimated the spatial extent of useful field of view, while the latest version measures visual processing speed. While deficits in the useful field of view are associated with functional impairments in everyday activities in older adults, there is also emerging evidence from several research groups that improvements in visual processing speed can be achieved through training. These improvements have been shown to reduce crash risk, and can have a positive impact on health and functional well-being, with the potential to increase the mobility and hence the independence of older adults. © 2014 S. Karger AG, Basel
Temporal visual field defects are associated with monocular inattention in chiasmal pathology.
Fledelius, Hans C
2009-11-01
Chiasmal lesions have been shown to give rise occasionally to uni-ocular temporal inattention, which cannot be compensated for by volitional eye movement. This article describes the assessments of 46 such patients with chiasmal pathology. It aims to determine the clinical spectrum of this disorder, including interference with reading. Retrospective consecutive observational clinical case study over a 7-year period comprising 46 patients with chiasmal field loss of varying degrees. Observation of reading behaviour during monocular visual acuity testing ascertained from consecutive patients who appeared unable to read optotypes on the temporal side of the chart. Visual fields were evaluated by kinetic (Goldmann) and static (Octopus) techniques. Five patients who clearly manifested this condition are presented in more detail. The results of visual field testing were related to absence or presence of uni-ocular visual inattentive behaviour for distance visual acuity testing and/or reading printed text. Despite normal eye movements, the 46 patients making up the clinical series perceived only optotypes in the nasal part of the chart, in one eye or in both, when tested for each eye in turn. The temporal optotypes were ignored, and this behaviour persisted despite instruction to search for any additional letters temporal to those, which had been seen. This phenomenon of unilateral visual inattention held for both eyes in 18 and was unilateral in the remaining 28 patients. Partial or full reversibility after treatment was recorded in 21 of the 39 for whom reliable follow-up data were available. Reading a text was affected in 24 individuals, and permanently so in six. A neglect-like spatial unawareness and a lack of cognitive compensation for varying degrees of temporal visual field loss were present in all the patients observed. Not only is visual field loss a feature of chiasmal pathology, but the higher visual function of affording attention within the temporal visual field by means of using conscious thought to invoke appropriate compensatory eye movement was also absent. This suggests the possibility of 'trans-synaptic dysfunction' caused by loss of visual input to higher visual centres. When inattention to the temporal side is manifest on monocular visual testing it should raise the suspicion of chiasmal pathology.
Comprehensive visual field test & diagnosis system in support of astronaut health and performance
NASA Astrophysics Data System (ADS)
Fink, Wolfgang; Clark, Jonathan B.; Reisman, Garrett E.; Tarbell, Mark A.
Long duration spaceflight, permanent human presence on the Moon, and future human missions to Mars will require autonomous medical care to address both expected and unexpected risks. An integrated non-invasive visual field test & diagnosis system is presented for the identification, characterization, and automated classification of visual field defects caused by the spaceflight environment. This system will support the onboard medical provider and astronauts on space missions with an innovative, non-invasive, accurate, sensitive, and fast visual field test. It includes a database for examination data, and a software package for automated visual field analysis and diagnosis. The system will be used to detect and diagnose conditions affecting the visual field, while in space and on Earth, permitting the timely application of therapeutic countermeasures before astronaut health or performance are impaired. State-of-the-art perimetry devices are bulky, thereby precluding application in a spaceflight setting. In contrast, the visual field test & diagnosis system requires only a touchscreen-equipped computer or touchpad device, which may already be in use for other purposes (i.e., no additional payload), and custom software. The system has application in routine astronaut assessment (Clinical Status Exam), pre-, in-, and post-flight monitoring, and astronaut selection. It is deployable in operational space environments, such as aboard the International Space Station or during future missions to or permanent presence on the Moon and Mars.
Experimental investigation of the visual field dependency in the erect and supine positions
NASA Technical Reports Server (NTRS)
Lichtenstein, J. H.; Saucer, R. T.
1972-01-01
The increasing utilization of simulators in many fields, in addition to aeronautics and space, requires the efficient use of these devices. It seemed that personnel highly influenced by the visual scene would make desirable subjects, particularly for those simulators without sufficient motion cues. In order to evaluate this concept, some measure of the degree of influence of the visual field on the subject in necessary. As part of this undertaking, 37 male and female subjects, including eight test pilots, were tested for their visual field dependency or independency. A version of Witkin's rod and frame apparatus was used for the tests. The results showed that nearly all the test subjects exhibited some degree of field dependency, the degree varying from very high field dependency to nearly zero field dependency in a normal distribution. The results for the test pilots were scattered throughout a range similar to the results for the bulk of male subjects. The few female subjects exhibited a higher field dependency than the male subjects. The male subjects exhibited a greater field dependency in the supine position than in the erect position, whereas the field dependency of the female subjects changed only slightly.
[New visual field testing possibilities (a preliminary report)].
Erichev, V P; Ermolaev, A P; Antonov, A A; Grigoryan, G L; Kosova, D V
2018-01-01
There are currently no portable mobile perimeters that allow visual field testing outside ophthalmologist's examination rooms. To develop a mobile perimetry technique based on use of a virtual reality headset (VR). The study involved 26 patients (30 eyes) with II-III stage primary open-angle glaucoma (POAG) with compensated IOP. Perimetry was performed for each patient twice - on Humphrey analyzer (test 30-2, 76 points) and employing similar strategy on a perimeter integrated into VR headset (Total Vision, Russia). Visual field testing was performed with an interval from 1 hour to 3 days. The results were comparatively analyzed. Patients tolerated the examination well. Comparative analysis of preliminary perimetry results obtained with both methods showed high degree of identity, so the results were concluded to be comparable. By visually isolating the wearer, VR headset achieves elimination of distractions and stable light conditions for visual field testing. The headset-perimeter is compact, mobile, easily transportable, can be used in the work of visiting medical teams and for examination at home.
Effect of Cognitive Demand on Functional Visual Field Performance in Senior Drivers with Glaucoma
Gangeddula, Viswa; Ranchet, Maud; Akinwuntan, Abiodun E.; Bollinger, Kathryn; Devos, Hannes
2017-01-01
Purpose: To investigate the effect of cognitive demand on functional visual field performance in drivers with glaucoma. Method: This study included 20 drivers with open-angle glaucoma and 13 age- and sex-matched controls. Visual field performance was evaluated under different degrees of cognitive demand: a static visual field condition (C1), dynamic visual field condition (C2), and dynamic visual field condition with active driving (C3) using an interactive, desktop driving simulator. The number of correct responses (accuracy) and response times on the visual field task were compared between groups and between conditions using Kruskal–Wallis tests. General linear models were employed to compare cognitive workload, recorded in real-time through pupillometry, between groups and conditions. Results: Adding cognitive demand (C2 and C3) to the static visual field test (C1) adversely affected accuracy and response times, in both groups (p < 0.05). However, drivers with glaucoma performed worse than did control drivers when the static condition changed to a dynamic condition [C2 vs. C1 accuracy; glaucoma: median difference (Q1–Q3) 3 (2–6.50) vs. controls: 2 (0.50–2.50); p = 0.05] and to a dynamic condition with active driving [C3 vs. C1 accuracy; glaucoma: 2 (2–6) vs. controls: 1 (0.50–2); p = 0.02]. Overall, drivers with glaucoma exhibited greater cognitive workload than controls (p = 0.02). Conclusion: Cognitive demand disproportionately affects functional visual field performance in drivers with glaucoma. Our results may inform the development of a performance-based visual field test for drivers with glaucoma. PMID:28912712
Mönter, Vera M; Crabb, David P; Artes, Paul H
2017-02-01
Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Thirty patients with glaucoma (median age 68, range 59-83 years; median Mean Deviation -8.0, range -16.3-0.1 dB) performed AKP and static automated perimetry (SAP) (German Adaptive Threshold Estimation strategy, 24-2 test). Automated kinetic perimetry consisted of a fully automated measurement of a single isopter (III.1.e). Central and peripheral visual fields were measured twice on the same day. Peripheral and central visual fields were only moderately related (Spearman's ρ, 0.51). Approximately 90% of test-retest differences in mean isopter radius were < ±4 deg. Relative to the range of measurements in this sample, the retest variability of AKP was similar to that of SAP. Patients with similar central visual field loss can have strikingly different peripheral visual fields, and therefore measuring the peripheral visual field may add clinically valuable information.
Quinn, Terence J; Livingstone, Iain; Weir, Alexander; Shaw, Robert; Breckenridge, Andrew; McAlpine, Christine; Tarbert, Claire M
2018-01-01
Visual impairment affects up to 70% of stroke survivors. We designed an app (StrokeVision) to facilitate screening for common post stroke visual issues (acuity, visual fields, and visual inattention). We sought to describe the test time, feasibility, acceptability, and accuracy of our app-based digital visual assessments against (a) current methods used for bedside screening and (b) gold standard measures. Patients were prospectively recruited from acute stroke settings. Index tests were app-based assessments of fields and inattention performed by a trained researcher. We compared against usual clinical screening practice of visual fields to confrontation, including inattention assessment (simultaneous stimuli). We also compared app to gold standard assessments of formal kinetic perimetry (Goldman or Octopus Visual Field Assessment); and pencil and paper-based tests of inattention (Albert's, Star Cancelation, and Line Bisection). Results of inattention and field tests were adjudicated by a specialist Neuro-ophthalmologist. All assessors were masked to each other's results. Participants and assessors graded acceptability using a bespoke scale that ranged from 0 (completely unacceptable) to 10 (perfect acceptability). Of 48 stroke survivors recruited, the complete battery of index and reference tests for fields was successfully completed in 45. Similar acceptability scores were observed for app-based [assessor median score 10 (IQR: 9-10); patient 9 (IQR: 8-10)] and traditional bedside testing [assessor 10 (IQR: 9-10); patient 10 (IQR: 9-10)]. Median test time was longer for app-based testing [combined time to completion of all digital tests 420 s (IQR: 390-588)] when compared with conventional bedside testing [70 s, (IQR: 40-70)], but shorter than gold standard testing [1,260 s, (IQR: 1005-1,620)]. Compared with gold standard assessments, usual screening practice demonstrated 79% sensitivity and 82% specificity for detection of a stroke-related field defect. This compares with 79% sensitivity and 88% specificity for StrokeVision digital assessment. StrokeVision shows promise as a screening tool for visual complications in the acute phase of stroke. The app is at least as good as usual screening and offers other functionality that may make it attractive for use in acute stroke. https://ClinicalTrials.gov/ct2/show/NCT02539381.
Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes
Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326
Recognizing patterns of visual field loss using unsupervised machine learning
NASA Astrophysics Data System (ADS)
Yousefi, Siamak; Goldbaum, Michael H.; Zangwill, Linda M.; Medeiros, Felipe A.; Bowd, Christopher
2014-03-01
Glaucoma is a potentially blinding optic neuropathy that results in a decrease in visual sensitivity. Visual field abnormalities (decreased visual sensitivity on psychophysical tests) are the primary means of glaucoma diagnosis. One form of visual field testing is Frequency Doubling Technology (FDT) that tests sensitivity at 52 points within the visual field. Like other psychophysical tests used in clinical practice, FDT results yield specific patterns of defect indicative of the disease. We used Gaussian Mixture Model with Expectation Maximization (GEM), (EM is used to estimate the model parameters) to automatically separate FDT data into clusters of normal and abnormal eyes. Principal component analysis (PCA) was used to decompose each cluster into different axes (patterns). FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal (i.e., glaucomatous) FDT results, recruited from a university-based, longitudinal, multi-center, clinical study on glaucoma. The GEM input was the 52-point FDT threshold sensitivities for all eyes. The optimal GEM model separated the FDT fields into 3 clusters. Cluster 1 contained 94% normal fields (94% specificity) and clusters 2 and 3 combined, contained 77% abnormal fields (77% sensitivity). For clusters 1, 2 and 3 the optimal number of PCA-identified axes were 2, 2 and 5, respectively. GEM with PCA successfully separated FDT fields from healthy and glaucoma eyes and identified familiar glaucomatous patterns of loss.
Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena
2014-01-01
Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario. PMID:24523869
Mazerand, Edouard; Le Renard, Marc; Hue, Sophie; Lemée, Jean-Michel; Klinger, Evelyne; Menei, Philippe
2017-01-01
Brain mapping during awake craniotomy is a well-known technique to preserve neurological functions, especially the language. It is still challenging to map the optic radiations due to the difficulty to test the visual field intraoperatively. To assess the visual field during awake craniotomy, we developed the Functions' Explorer based on a virtual reality headset (FEX-VRH). The impaired visual field of 10 patients was tested with automated perimetry (the gold standard examination) and the FEX-VRH. The proof-of-concept test was done during the surgery performed on a patient who was blind in his right eye and presenting with a left parietotemporal glioblastoma. The FEX-VRH was used intraoperatively, simultaneously with direct subcortical electrostimulation, allowing identification and preservation of the optic radiations. The FEX-VRH detected 9 of the 10 visual field defects found by automated perimetry. The patient who underwent an awake craniotomy with intraoperative mapping of the optic tract using the FEX-VRH had no permanent postoperative visual field defect. Intraoperative visual field assessment with the FEX-VRH during direct subcortical electrostimulation is a promising approach to mapping the optical radiations and preventing a permanent visual field defect during awake surgery for epilepsy or tumor. Copyright © 2016 Elsevier Inc. All rights reserved.
Korogi, Y; Takahashi, M; Hirai, T; Ikushima, I; Kitajima, M; Sugahara, T; Shigematsu, Y; Okajima, T; Mukuno, K
1997-01-01
To compare MR imaging findings of the striate cortex with visual field deficits in patients with Minamata disease and to reestimate the classical Holmes retinotopic map by using the data obtained from comparing visual field abnormalities with degree of visual cortex atrophy. MR imaging was performed in eight patients with Minamata disease who had been given a full neuroophthalmic examination, including Goldmann dynamic perimetry. The atrophic portions of the calcarine area were measured in the sagittal plane next to the midsagittal image and represented as a percentage of atrophy of the total length of the calcarine fissure. MR findings were compared with results of a visual field test. The visual field test revealed moderate to severe concentric constriction of the visual fields, with central vision ranging from 7 degrees to 42 degrees (mean, 19 degrees). The ventral portion of the calcarine sulcus was significantly dilated on MR images in all patients. A logarithmic correlation was found between the visual field defect and the extent of dilatation of the calcarine fissure. The central 10 degrees and 30 degrees of vision seemed to fill about 20% and 50% of the total surface area of the calcarine cortex, respectively. Visual field deficits in patients with Minamata disease correlated well with MR findings of the striate cortex. Our data were consistent with the classical Holmes retinotopic map.
McTrusty, Alice D; Cameron, Lorraine A; Perperidis, Antonios; Brash, Harry M; Tatham, Andrew J; Agarwal, Pankaj K; Murray, Ian C; Fleck, Brian W; Minns, Robert A
2017-09-01
We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.
Kocabeyoglu, Sibel; Uzun, Salih; Mocan, Mehmet Cem; Bozkurt, Banu; Irkec, Murat; Orhan, Mehmet
2013-10-01
The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT) perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD]) were compared between the 2 tests using the Wilcoxon signed-rank test and paired t-test. The performance of the Humphrey field analyzer (HFA) 24-2 SITA-standard and frequency-doubling technology Matrix 24-2 tests between genders were compared with Mann-Whitney U-test. Fifty-five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years) were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651). MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P < 0.001), and fixation losses and false negative errors were significantly less with SAP (P < 0.05). A weak positive correlation between the two tests in terms of MD (r = 0.352, P = 0.008) and PSD (r = 0.329, P = 0.014) was observed. Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow-up of children.
Natural course of visual field loss in patients with Type 2 Usher syndrome.
Fishman, Gerald A; Bozbeyoglu, Simge; Massof, Robert W; Kimberling, William
2007-06-01
To evaluate the natural course of visual field loss in patients with Type 2 Usher syndrome and different patterns of visual field loss. Fifty-eight patients with Type 2 Usher syndrome who had at least three visual field measurements during a period of at least 3 years were studied. Kinetic visual fields measured on a standard calibrated Goldmann perimeter with II4e and V4e targets were analyzed. The visual field areas in both eyes were determined by planimetry with the use of a digitalizing tablet and computer software and expressed in square inches. The data for each visual field area measurement were transformed to a natural log unit. Using a mixed model regression analysis, values for the half-life of field loss (time during which half of the remaining field area is lost) were estimated. Three different patterns of visual field loss were identified, and the half-life time for each pattern of loss was calculated. Of the 58 patients, 11 were classified as having pattern type I, 12 with pattern type II, and 14 with pattern type III. Of 21 patients whose visual field loss was so advanced that they could not be classified, 15 showed only a small residual central field (Group A) and 6 showed a residual central field with a peripheral island (Group B). The average half-life times varied between 3.85 and 7.37 for the II4e test target and 4.59 to 6.42 for the V4e target. There was no statistically significant difference in the half-life times between the various patterns of field loss or for the test targets. The average half-life times for visual field loss in patients with Usher syndrome Type 2 were statistically similar among those patients with different patterns of visual field loss. These findings will be useful for counseling patients with Type 2 Usher syndrome as to their prognosis for anticipated visual field loss.
Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio
2015-01-01
To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.
Evaluation of peripheral binocular visual field in patients with glaucoma: a pilot study
Ana, Banc; Cristina, Stan; Dorin, Chiselita
2016-01-01
Objective: The objective of this study was to evaluate the peripheral binocular visual field (PBVF) in patients with glaucoma using the threshold strategy of Humphrey Field Analyzer. Methods: We conducted a case-control pilot study in which we enrolled 59 patients with glaucoma and 20 controls. All participants were evaluated using a custom PBVF test and central 24° monocular visual field tests for each eye using the threshold strategy. The central binocular visual field (CBVF) was predicted from the monocular tests using the most sensitive point at each field location. The glaucoma patients were grouped according to Hodapp classification and age. The PBVF was compared to controls and the relationship between the PBVF and CBVF was tested. Results: The areas of frame-induced artefacts were determined (over 50° in each temporal field, 24° superiorly and 45° inferiorly) and excluded from interpretation. The patients presented a statistically significant generalized decrease of the peripheral retinal sensitivity compared to controls for Hodapp initial stage - groups aged 50-59 (t = 11.93 > 2.06; p < 0.05) and 60-69 (t = 7.55 > 2.06; p < 0.05). For the initial Hodapp stage there was no significant relationship between PBVF and CBVF (r = 0.39). For the moderate and advanced Hodapp stages, the interpretation of data was done separately for each patient. Conclusions: This pilot study suggests that glaucoma patients present a decrease of PBVF compared to controls and CBVF cannot predict the PBVF in glaucoma. Abbreviations: CBVF = central binocular visual field, PBVF = peripheral binocular visual field, MD = mean deviation PMID:27220228
Detection of Visual Field Loss in Pituitary Disease: Peripheral Kinetic Versus Central Static
Rowe, Fiona J.; Cheyne, Christopher P.; García-Fiñana, Marta; Noonan, Carmel P.; Howard, Claire; Smith, Jayne; Adeoye, Joanne
2015-01-01
Abstract Visual field assessment is an important clinical evaluation for eye disease and neurological injury. We evaluated Octopus semi-automated kinetic peripheral perimetry (SKP) and Humphrey static automated central perimetry for detection of neurological visual field loss in patients with pituitary disease. We carried out a prospective cross-sectional diagnostic accuracy study comparing Humphrey central 30-2 SITA threshold programme with a screening protocol for SKP on Octopus perimetry. Humphrey 24-2 data were extracted from 30-2 results. Results were independently graded for presence/absence of field defect plus severity of defect. Fifty patients (100 eyes) were recruited (25 males and 25 females), with mean age of 52.4 years (SD = 15.7). Order of perimeter assessment (Humphrey/Octopus first) and order of eye tested (right/left first) were randomised. The 30-2 programme detected visual field loss in 85%, the 24-2 programme in 80%, and the Octopus combined kinetic/static strategy in 100% of eyes. Peripheral visual field loss was missed by central threshold assessment. Qualitative comparison of type of visual field defect demonstrated a match between Humphrey and Octopus results in 58%, with a match for severity of defect in 50%. Tests duration was 9.34 minutes (SD = 2.02) for Humphrey 30-2 versus 10.79 minutes (SD = 4.06) for Octopus perimetry. Octopus semi-automated kinetic perimetry was found to be superior to central static testing for detection of pituitary disease-related visual field loss. Where reliant on Humphrey central static perimetry, the 30-2 programme is recommended over the 24-2 programme. Where kinetic perimetry is available, this is preferable to central static programmes for increased detection of peripheral visual field loss. PMID:27928344
Visual field defects after temporal lobe resection for epilepsy.
Steensberg, Alvilda T; Olsen, Ane Sophie; Litman, Minna; Jespersen, Bo; Kolko, Miriam; Pinborg, Lars H
2018-01-01
To determine visual field defects (VFDs) using methods of varying complexity and compare results with subjective symptoms in a population of newly operated temporal lobe epilepsy patients. Forty patients were included in the study. Two patients failed to perform VFD testing. Humphrey Field Analyzer (HFA) perimetry was used as the gold standard test to detect VFDs. All patients performed a web-based visual field test called Damato Multifixation Campimetry Online (DMCO). A bedside confrontation visual field examination ad modum Donders was extracted from the medical records in 27/38 patients. All participants had a consultation by an ophthalmologist. A questionnaire described the subjective complaints. A VFD in the upper quadrant was demonstrated with HFA in 29 (76%) of the 38 patients after surgery. In 27 patients tested ad modum Donders, the sensitivity of detecting a VFD was 13%. Eight patients (21%) had a severe VFD similar to a quadrant anopia, thus, questioning their permission to drive a car. In this group of patients, a VFD was demonstrated in one of five (sensitivity=20%) ad modum Donders and in seven of eight (sensitivity=88%) with DMCO. Subjective symptoms were only reported by 28% of the patients with a VFD and in two of eight (sensitivity=25%) with a severe VFD. Most patients (86%) considered VFD information mandatory. VFD continue to be a frequent adverse event after epilepsy surgery in the medial temporal lobe and may affect the permission to drive a car in at least one in five patients. Subjective symptoms and bedside visual field testing ad modum Donders are not sensitive to detect even a severe VFD. Newly developed web-based visual field test methods appear sensitive to detect a severe VFD but perimetry remains the golden standard for determining if visual standards for driving is fulfilled. Patients consider VFD information as mandatory. Copyright © 2017. Published by Elsevier Ltd.
Optic nerve dysfunction during gravity inversion. Visual field abnormalities.
Sanborn, G E; Friberg, T R; Allen, R
1987-06-01
Inversion in a head-down position (gravity inversion) results in an intraocular pressure of 35 to 40 mm Hg in normal subjects. We used computerized static perimetry to measure the visual fields of normal subjects during gravity inversion. There were no visual field changes in the central 6 degrees of the visual field compared with the baseline (preinversion) values. However, when the central 30 degrees of the visual field was tested, reversible visual field defects were found in 11 of 19 eyes. We believe that the substantial elevation of intraocular pressure during gravity inversion may pose potential risks to the eyes, and we recommend that inversion for extended periods of time be avoided.
Visual field impairment captures disease burden in multiple sclerosis.
Ortiz-Perez, Santiago; Andorra, Magí; Sanchez-Dalmau, Bernardo; Torres-Torres, Rubén; Calbet, David; Lampert, Erika J; Alba-Arbalat, Salut; Guerrero-Zamora, Ana M; Zubizarreta, Irati; Sola-Valls, Nuria; Llufriu, Sara; Sepúlveda, María; Saiz, Albert; Villoslada, Pablo; Martinez-Lapiscina, Elena H
2016-04-01
Monitoring disease burden is an unmeet need in multiple sclerosis (MS). Identifying patients at high risk of disability progression will be useful for improving clinical-therapeutic decisions in clinical routine. To evaluate the role of visual field testing in non-optic neuritis eyes (non-ON eyes) as a biomarker of disability progression in MS. In 109 patients of the MS-VisualPath cohort, we evaluated the association between visual field abnormalities and global and cognitive disability markers and brain and retinal imaging markers of neuroaxonal injury using linear regression models adjusted for sex, age, disease duration and use of disease-modifying therapies. We evaluated the risk of disability progression associated to have baseline impaired visual field after 3 years of follow-up. Sixty-two percent of patients showed visual field defects in non-ON eyes. Visual field mean deviation was statistically associated with global disability; brain (normalized brain parenchymal, gray matter volume and lesion load) and retinal (peripapillary retinal nerve fiber layer thickness and macular ganglion cell complex thickness) markers of neuroaxonal damage. Patients with impaired visual field had statistically significative greater disability, lower normalized brain parenchymal volume and higher lesion volume than patients with normal visual field testing. MS patients with baseline impaired VF tripled the risk of disability progression during follow-up [OR = 3.35; 95 % CI (1.10-10.19); p = 0.033]. The association of visual field impairment with greater disability and neuroaxonal injury and higher risk of disability progression suggest that VF could be used to monitor MS disease burden.
Anxiety in visual field testing.
Chew, Shenton S L; Kerr, Nathan M; Wong, Aaron B C; Craig, Jennifer P; Chou, Chi-Ying; Danesh-Meyer, Helen V
2016-08-01
To determine if Humphrey visual field (HVF) testing induces anxiety and how anxiety relates to visual field parameters of reliability and severity. A prospective cohort study at a university affiliated private ophthalmic practice. 137 consecutive age-matched and gender-matched patients with glaucoma undergoing either HVF testing only (n=102) or Heidelberg retinal tomography (HRT) only (n=35) were enrolled. Prior to testing, participants completed the State-Trait Anxiety Inventory questionnaire. A 5-point Likert scale was used to grade pretest anxiety and was repeated after testing to grade intratest anxiety. Subjective discomfort parameters were also recorded. Anxiety scores were used to make non-parametrical comparisons and correlations between cohorts and also against visual field reliability and severity indices. Trait anxiety (p=0.838) and pretest anxiety (p=0.802) were not significantly different between test groups. Within the HVF group, intratest anxiety was 1.2 times higher than pretest anxiety (p=0.0001), but was not significantly different in the HRT group (p=0.145). Pretest anxiety was correlated with test unreliability (Spearman's r=0.273, p=0.006), which was predictive of worse test severity (p=0.0027). Subjects who had undergone more than 10 visual field tests had significantly lower pretest and intratest anxiety levels than those who had not (p=0.0030 and p=0.0004, respectively). HVF testing induces more anxiety than HRT. Increased pretest anxiety may reduce HVF test reliability. Increased test experience or interventions aimed at reducing pretest anxiety may result in improved test reliability and accuracy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
... optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when it becomes suddenly ... may include: Color vision testing MRI of the brain , including special images of the optic nerve Visual acuity testing Visual field testing Examination of the ...
Wu, Zhichao; Medeiros, Felipe A
2018-03-20
Visual field testing is an important endpoint in glaucoma clinical trials, and the testing paradigm used can have a significant impact on the sample size requirements. To investigate this, this study included 353 eyes of 247 glaucoma patients seen over a 3-year period to extract real-world visual field rates of change and variability estimates to provide sample size estimates from computer simulations. The clinical trial scenario assumed that a new treatment was added to one of two groups that were both under routine clinical care, with various treatment effects examined. Three different visual field testing paradigms were evaluated: a) evenly spaced testing, b) United Kingdom Glaucoma Treatment Study (UKGTS) follow-up scheme, which adds clustered tests at the beginning and end of follow-up in addition to evenly spaced testing, and c) clustered testing paradigm, with clusters of tests at the beginning and end of the trial period and two intermediary visits. The sample size requirements were reduced by 17-19% and 39-40% using the UKGTS and clustered testing paradigms, respectively, when compared to the evenly spaced approach. These findings highlight how the clustered testing paradigm can substantially reduce sample size requirements and improve the feasibility of future glaucoma clinical trials.
Properties of the statpac visual field index.
Artes, Paul H; O'Leary, Neil; Hutchison, Donna M; Heckler, Lisa; Sharpe, Glen P; Nicolela, Marcelo T; Chauhan, Balwantray C
2011-06-08
Purpose. To compare the properties of the visual field index (VFI) to those of mean deviation (MD) in patients with glaucoma. Methods. MD and VFI were calculated in data obtained from an ongoing longitudinal study in which patients with glaucoma (N = 109, 204 eyes) were observed for 9.8 years (median, 21 tests) with static automated perimetry. MD and VFI were compared in one test of each eye, and a subset of 30 tests were selected to compare the VFI with the judgments of eight experts who judged the percentage of the remaining visual field. In series of tests obtained over time, rates of change, statistical significance, evidence of nonlinearity, and variability were compared between both indices. Results. In single tests, MD and VFI were closely related (r = 0.88, P < 0.001). The relationship between both indices appeared linear, except in visual fields with MDs better than -5.0 dB where 29 (22%) of 129 eyes exhibited a ceiling effect (VFI = 100%). Based on this relationship, the predicted VFIs for visual fields with MDs of -5, -10, and -15 dB were 91%, 76%, and 60%, respectively. The percentage of remaining visual field suggested by the VFI exceeded the range of the experts' subjective judgments in 16 (53%) of 30 eyes. In series of tests obtained over time, rates of change with the two indices were closely related (r = 0.79, P < 0.001), and statistically significant reductions over time (P < 0.05) occurred in a similar number of eyes (92 [45%] with MD, and 87 [43%] with VFI). Of the 105 eyes with statistically significant (P < 0.05) negative trend in either MD or VFI, 74 (70%) showed such trends with both indices (κ = 0.69). The variability of MD and VFI increased with damage, and there was no evidence that change over time was more linear with VFI than with MD. Conclusions. The VFI provides a simple and understandable metric of visual field damage, but its estimates of remaining visual field were more optimistic than those of the experts. Rates of change over time with both indices were closely related, but the reliance of the VFI on pattern deviation probability maps caused a ceiling effect that may have reduced its sensitivity to change in eyes with early damage. In this group of patients there was no evidence to suggest that the VFI is either superior or inferior to the MD as a summary measure of visual field damage.
NASA Astrophysics Data System (ADS)
Utomo, Edy Setiyo; Juniati, Dwi; Siswono, Tatag Yuli Eko
2017-08-01
The aim of this research was to describe the mathematical visualization process of Junior High School students in solving contextual problems based on cognitive style. Mathematical visualization process in this research was seen from aspects of image generation, image inspection, image scanning, and image transformation. The research subject was the students in the eighth grade based on GEFT test (Group Embedded Figures Test) adopted from Within to determining the category of cognitive style owned by the students namely field independent or field dependent and communicative. The data collection was through visualization test in contextual problem and interview. The validity was seen through time triangulation. The data analysis referred to the aspect of mathematical visualization through steps of categorization, reduction, discussion, and conclusion. The results showed that field-independent and field-dependent subjects were difference in responding to contextual problems. The field-independent subject presented in the form of 2D and 3D, while the field-dependent subject presented in the form of 3D. Both of the subjects had different perception to see the swimming pool. The field-independent subject saw from the top, while the field-dependent subject from the side. The field-independent subject chose to use partition-object strategy, while the field-dependent subject chose to use general-object strategy. Both the subjects did transformation in an object rotation to get the solution. This research is reference to mathematical curriculum developers of Junior High School in Indonesia. Besides, teacher could develop the students' mathematical visualization by using technology media or software, such as geogebra, portable cabri in learning.
Doerschner, K.; Boyaci, H.; Maloney, L. T.
2007-01-01
We investigated limits on the human visual system’s ability to discount directional variation in complex lights field when estimating Lambertian surface color. Directional variation in the light field was represented in the frequency domain using spherical harmonics. The bidirectional reflectance distribution function of a Lambertian surface acts as a low-pass filter on directional variation in the light field. Consequently, the visual system needs to discount only the low-pass component of the incident light corresponding to the first nine terms of a spherical harmonics expansion (Basri & Jacobs, 2001; Ramamoorthi & Hanrahan, 2001) to accurately estimate surface color. We test experimentally whether the visual system discounts directional variation in the light field up to this physical limit. Our results are consistent with the claim that the visual system can compensate for all of the complexity in the light field that affects the appearance of Lambertian surfaces. PMID:18053846
Rubin, G S; West, S K; Muñoz, B; Bandeen-Roche, K; Zeger, S; Schein, O; Fried, L P
1997-03-01
The Salisbury Eye Evaluation Project is a longitudinal study of risk factors for age-related eye diseases and the impact of eye disease and visual impairment on physical disability. In this article, the authors report the prevalence of visual impairment in their population and explore the relations among the various measures of visual function. A population-based sample of 2520 residents of Salisbury, Maryland, between the ages of 65 and 84 years were enrolled in the study. Twenty-six percent of participants were black. Vision tests included best-corrected Early Treatment Diabetic Retinopathy Study acuity, Pelli-Robson contrast sensitivity with and without glare, Randot stereoacuity, and 60 degrees Humphrey visual fields. Visual function decreased linearly with age for the acuity, contrast sensitivity, glare, and visual field tests. Stereoacuity remained constant into the mid-70s and declined at an accelerating rate thereafter. Black participants had lower contrast sensitivity, reduced stereoacuity, and worse visual fields, at all ages compared to white participants; however, white participants were more sensitive to glare. The overall prevalence of visual acuity impairment in blacks was 5.6% versus 3.0% for whites, using the traditional United States definition (worse than 20/40 to better than 20/200) and 3.3% for blacks versus 1.6% for whites, using the World Health Organization definition (worse than 20/60 to 20/400). Acuity was correlated moderately with contrast sensitivity, stereoacuity, and visual fields (Spearman rho = 0.50, 0.35, and 0.34, respectively). The correlation between acuity and glare sensitivity was low (rho = 0.12). Many aspects of visual function, not just acuity, decline with age. Black participants have more visual impairement than do white participants for all tests except glare sensitivity. The prevalence of visual acuity impairement in the Salisbury Eye Evaluation population is lower than that reported by other studies using similar test procedures. Low-to-moderate correlations among vision test scores suggest that several different dimensions of visual function are being assessed.
Task set induces dynamic reallocation of resources in visual short-term memory.
Sheremata, Summer L; Shomstein, Sarah
2017-08-01
Successful interaction with the environment requires the ability to flexibly allocate resources to different locations in the visual field. Recent evidence suggests that visual short-term memory (VSTM) resources are distributed asymmetrically across the visual field based upon task demands. Here, we propose that context, rather than the stimulus itself, determines asymmetrical distribution of VSTM resources. To test whether context modulates the reallocation of resources to the right visual field, task set, defined by memory-load, was manipulated to influence visual short-term memory performance. Performance was measured for single-feature objects embedded within predominantly single- or two-feature memory blocks. Therefore, context was varied to determine whether task set directly predicts changes in visual field biases. In accord with the dynamic reallocation of resources hypothesis, task set, rather than aspects of the physical stimulus, drove improvements in performance in the right- visual field. Our results show, for the first time, that preparation for upcoming memory demands directly determines how resources are allocated across the visual field.
Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C
2005-07-01
To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.
The repeatability of mean defect with size III and size V standard automated perimetry.
Wall, Michael; Doyle, Carrie K; Zamba, K D; Artes, Paul; Johnson, Chris A
2013-02-15
The mean defect (MD) of the visual field is a global statistical index used to monitor overall visual field change over time. Our goal was to investigate the relationship of MD and its variability for two clinically used strategies (Swedish Interactive Threshold Algorithm [SITA] standard size III and full threshold size V) in glaucoma patients and controls. We tested one eye, at random, for 46 glaucoma patients and 28 ocularly healthy subjects with Humphrey program 24-2 SITA standard for size III and full threshold for size V each five times over a 5-week period. The standard deviation of MD was regressed against the MD for the five repeated tests, and quantile regression was used to show the relationship of variability and MD. A Wilcoxon test was used to compare the standard deviations of the two testing methods following quantile regression. Both types of regression analysis showed increasing variability with increasing visual field damage. Quantile regression showed modestly smaller MD confidence limits. There was a 15% decrease in SD with size V in glaucoma patients (P = 0.10) and a 12% decrease in ocularly healthy subjects (P = 0.08). The repeatability of size V MD appears to be slightly better than size III SITA testing. When using MD to determine visual field progression, a change of 1.5 to 4 decibels (dB) is needed to be outside the normal 95% confidence limits, depending on the size of the stimulus and the amount of visual field damage.
[Case of brain infarction in the anterior choroidal artery territory with homonymous scotomas].
Nakae, Yoshiharu; Higashiyama, Yuichi; Kuroiwa, Yoshiyuki
2009-08-01
We report a case of brain infarction in the anterior choroidal artery territory accompanied homonymous scotomas. A 59-year-old man with diabetes mellitus felt weakness in his left upper and lower extremities. He was admitted to our hospital with mild hemiparesis on his left side. He noticed a small black spot in the left inferior portion of his visual field; however, this disappeared within one minute. He had no visual defects as assessed by a confrontation test, but a Goldmann visual field test revealed that there were homonymous scotomas in the left inferior portion of the visual field. Brain MRI showed hyperintense signals on diffusion-weighted images in the territory of the right anterior choroidal artery. He was diagnosed as having a brain infarction. The anterior choroidal artery penetrates the lateral geniculate nucleus from the front, and branches of the artery usually supply the medial and lateral parts of the lateral geniculate nucleus. Occlusion of these branches causes the loss of the upper and lower homonymous sectors in the visual field. The present case exhibited homonymous scotomas. We assumed that our patient's homonymous scotomas were a variant form of wedge-shaped visual field deficits often seen in anterior choroidal artery syndrome. On the basis the experience gained in this case, we consider that patients with brain infarction in the anterior choroidal artery territory should undergo ophthalmological examination, even when no visual defects are detected by a confrontation test.
Visual field defects after missile injuries to the geniculo-striate pathway in man.
NASA Technical Reports Server (NTRS)
Koerner, F.; Teuber, H.-L.
1973-01-01
The main objective of the survey reported was a quantitative comparison of different visual functions at identical retinal points of individual patients. The possibility to develop objective forms of visual-field testing was also explored, taking into account reports by Frydrychowicz and Harms (1940) and Harms (1951). These investigators had insisted that pupillary responses to light are depressed in areas of homonymous scotomata. The shapes of homonymous visual field defects are discussed together with questions regarding the association and dissociation of symptoms.
Investigation of outside visual cues required for low speed and hover
NASA Technical Reports Server (NTRS)
Hoh, R. H.
1985-01-01
Knowledge of the visual cues required in the performance of stabilized hover in VTOL aircraft is a prerequisite for the development of both cockpit displays and ground-based simulation systems. Attention is presently given to the viability of experimental test flight techniques as the bases for the identification of essential external cues in aggressive and precise low speed and hovering tasks. The analysis and flight test program conducted employed a helicopter and a pilot wearing lenses that could be electronically fogged, where the primary variables were field-of-view, large object 'macrotexture', and fine detail 'microtexture', in six different fields-of-view. Fundamental metrics are proposed for the quantification of the visual field, to allow comparisons between tests, simulations, and aircraft displays.
Optoelectronic aid for patients with severely restricted visual fields in daylight conditions
NASA Astrophysics Data System (ADS)
Peláez-Coca, María Dolores; Sobrado-Calvo, Paloma; Vargas-Martín, Fernando
2011-11-01
In this study we evaluated the immediate effectiveness of an optoelectronic visual field expander in a sample of subjects with retinitis pigmentosa suffering from a severe peripheral visual field restriction. The aid uses the augmented view concept and provides subjects with visual information from outside their visual field. The tests were carried out in daylight conditions. The optoelectronic aid comprises a FPGA (real-time video processor), a wide-angle mini camera and a transparent see-through head-mounted display. This optoelectronic aid is called SERBA (Sistema Electro-óptico Reconfigurable de Ayuda para Baja Visión). We previously showed that, without compromising residual vision, the SERBA system provides information about objects within an area about three times greater on average than the remaining visual field of the subjects [1]. In this paper we address the effects of the device on mobility under daylight conditions with and without SERBA. The participants were six subjects with retinitis pigmentosa. In this mobility test, better results were obtained when subjects were wearing the SERBA system; specifically, both the number of contacts with low-level obstacles and mobility errors decreased significantly. A longer training period with the device might improve its usefulness.
Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.
Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki
2014-02-01
To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.
VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry
Weleber, Richard G.; Smith, Travis B.; Peters, Dawn; Chegarnov, Elvira N.; Gillespie, Scott P.; Francis, Peter J.; Gardiner, Stuart K.; Paetzold, Jens; Dietzsch, Janko; Schiefer, Ulrich; Johnson, Chris A.
2015-01-01
Purpose: To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. Methods: A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. Results: Cross-validation yielded an overall R2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test–retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. Conclusions: VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. Translational Relevance: VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials. PMID:25938002
Objective Measures of Visual Function in Papilledema
Moss, Heather E.
2016-01-01
Synopsis Visual function is an important parameter to consider when managing patients with papilledema. Though the current standard of care uses standard automated perimetry (SAP) to obtain this information, this test is inherently subjective and prone to patient errors. Objective visual function tests including the visual evoked potential, pattern electroretinogram, photopic negative response of the full field electroretinogram, and pupillary light response have the potential to replace or supplement subjective visual function tests in papilledema management. This article reviews the evidence for use of objective visual function tests to assess visual function in papilledema and discusses future investigations needed to develop them as clinically practical and useful measures for this purpose. PMID:28451649
Poggel, Dorothe A.; Treutwein, Bernhard; Sabel, Bernhard A.; Strasburger, Hans
2015-01-01
The issue of how basic sensory and temporal processing are related is still unresolved. We studied temporal processing, as assessed by simple visual reaction times (RT) and double-pulse resolution (DPR), in patients with partial vision loss after visual pathway lesions and investigated whether vision restoration training (VRT), a training program designed to improve light detection performance, would also affect temporal processing. Perimetric and campimetric visual field tests as well as maps of DPR thresholds and RT were acquired before and after a 3 months training period with VRT. Patient performance was compared to that of age-matched healthy subjects. Intact visual field size increased during training. Averaged across the entire visual field, DPR remained constant while RT improved slightly. However, in transition zones between the blind and intact areas (areas of residual vision) where patients had shown between 20 and 80% of stimulus detection probability in pre-training visual field tests, both DPR and RT improved markedly. The magnitude of improvement depended on the defect depth (or degree of intactness) of the respective region at baseline. Inter-individual training outcome variability was very high, with some patients showing little change and others showing performance approaching that of healthy controls. Training-induced improvement of light detection in patients with visual field loss thus generalized to dynamic visual functions. The findings suggest that similar neural mechanisms may underlie the impairment and subsequent training-induced functional recovery of both light detection and temporal processing. PMID:25717307
The retest distribution of the visual field summary index mean deviation is close to normal.
Anderson, Andrew J; Cheng, Allan C Y; Lau, Samantha; Le-Pham, Anne; Liu, Victor; Rahman, Farahnaz
2016-09-01
When modelling optimum strategies for how best to determine visual field progression in glaucoma, it is commonly assumed that the summary index mean deviation (MD) is normally distributed on repeated testing. Here we tested whether this assumption is correct. We obtained 42 reliable 24-2 Humphrey Field Analyzer SITA standard visual fields from one eye of each of five healthy young observers, with the first two fields excluded from analysis. Previous work has shown that although MD variability is higher in glaucoma, the shape of the MD distribution is similar to that found in normal visual fields. A Shapiro-Wilks test determined any deviation from normality. Kurtosis values for the distributions were also calculated. Data from each observer passed the Shapiro-Wilks normality test. Bootstrapped 95% confidence intervals for kurtosis encompassed the value for a normal distribution in four of five observers. When examined with quantile-quantile plots, distributions were close to normal and showed no consistent deviations across observers. The retest distribution of MD is not significantly different from normal in healthy observers, and so is likely also normally distributed - or nearly so - in those with glaucoma. Our results increase our confidence in the results of influential modelling studies where a normal distribution for MD was assumed. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos
2009-01-01
To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 +/- 0.6 years). Color vision defects were studied using a special computer program for Farnsworth-Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30-2. Both tests were repeated every six months. In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 +/- 31.79) and OH eyes (75.51 +/- 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was -20.62 +/- 2.75 (t value 9.08, p < 0.001) while in OH eyes was -2.11 +/- 4.36 (t value 1.1, p = 0.276). Pearson's coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields.
Vision restoration therapy does not benefit from costimulation: A pilot study.
Kasten, Erich; Bunzenthal, Ulrike; Müller-Oehring, Eva M; Mueller, Iris; Sabel, Bernhard A
2007-08-01
Visual field deficits in patients have long been considered to be nontreatable, but in previous studies we have found an enlargement of the intact visual field following vision restoration therapy (VRT). In the present pilot study, we wished to determine whether a double-stimulation approach would facilitate visual field enlargements beyond those achieved by the single-stimulus paradigm used in standard VRT. This was motivated by the findings that following visual cortex injury in animals, the size of receptive fields could be enlarged by systematic costimulation, where two stimuli were used to excite visual cortex neurons (Eysel, Eyding, & Schweigart, 1998). Patients (n = 23) with stable homonymous field deficits after trauma, cerebral ischemia, or hemorrhage (lesion age > 6 months) carried out either (a) standard VRT with a single stimulation (n = 9), or vision therapy with (b) a parallel costimulation (n = 7) or (c) a moving costimulation paradigm (n = 7). Training was carried out twice daily for 30 min over a 3-month period. Before and after therapy, visual fields were tested with 30 degrees and 90 degrees Tübinger automatic perimetry (TAP) and with high-resolution perimetry (HRP). Eye movements were recorded with an eye tracking system. When data of all three types of visual field training were pooled, we found significant improvements of stimulus detection in HRP (4.2%) and fewer misses within the central 30 degrees perimetrically (-3.7% right eye, OD, or -4.4% left eye, OS). However, the type of training did not make any difference such that the three training groups profited equally. A more detailed analysis of trained versus untrained visual field areas in 16 patients revealed a superiority of the trained area of only 1.1% in HRP and between 3.5% (OS) and 4.4% (OD) in TAP. Spatial attention and alertness improved significantly in all three groups and correlated significantly with visual field enlargements. While vision training had no influence on the patient's testimonials concerning their visual abilities, the patients significantly improved in a practical paper-and-pencil number tracking task (Zahlen-Verbindungs Test; ZVT). Visual field enlargement does not benefit from a double-stimulation paradigm, but visual attention seems to play an important role in vision restoration. The improvements in trained as well as in untrained areas are explained by top-down attentional control mechanisms interacting with local visual cortex plasticity.
Evaluation of peripheral binocular visual field in patients with glaucoma: a pilot study.
Ana, Banc; Cristina, Stan; Dorin, Chiselita
2016-01-01
The objective of this study was to evaluate the peripheral binocular visual field (PBVF) in patients with glaucoma using the threshold strategy of Humphrey Field Analyzer. We conducted a case-control pilot study in which we enrolled 59 patients with glaucoma and 20 controls. All participants were evaluated using a custom PBVF test and central 24 degrees monocular visual field tests for each eye using the threshold strategy. The central binocular visual field (CBVF) was predicted from the monocular tests using the most sensitive point at each field location. The glaucoma patients were grouped according to Hodapp classification and age. The PBVF was compared to controls and the relationship between the PBVF and CBVF was tested. The areas of frame-induced artefacts were determined (over 50 degrees in each temporal field, 24 degrees superiorly and 45 degrees inferiorly) and excluded from interpretation. The patients presented a statistically significant generalized decrease of the peripheral retinal sensitivity compared to controls for Hodapp initial stage--groups aged 50-59 (t = 11.93 > 2.06; p < 0.05) and 60-69 (t = 7.55 > 2.06; p < 0.05). For the initial Hodapp stage there was no significant relationship between PBVF and CBVF (r = 0.39). For the moderate and advanced Hodapp stages, the interpretation of data was done separately for each patient. This pilot study suggests that glaucoma patients present a decrease of PBVF compared to controls and CBVF cannot predict the PBVF in glaucoma.
Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.
Teoh, S L; Allan, D; Dutton, G N; Foulds, W S
1990-04-01
The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma.
Wu, Zhichao; Saunders, Luke J; Daga, Fábio B; Diniz-Filho, Alberto; Medeiros, Felipe A
2017-06-01
To determine the time required to detect statistically significant progression for different rates of visual field loss using standard automated perimetry (SAP) when considering different frequencies of testing using a follow-up scheme that resembles clinical practice. Observational cohort study. One thousand seventy-two eyes of 665 patients with glaucoma followed up over an average of 4.3±0.9 years. Participants with 5 or more visual field tests over a 2- to 5-year period were included to derive the longitudinal measurement variability of SAP mean deviation (MD) using linear regressions. Estimates of variability then were used to reconstruct real-world visual field data by computer simulation to evaluate the time required to detect progression for various rates of visual field loss and different frequencies of testing. The evaluation was performed using a follow-up scheme that resembled clinical practice by requiring a set of 2 baseline tests and a confirmatory test to identify progression. Time (in years) required to detect progression. The time required to detect a statistically significant negative MD slope decreased as the frequency of testing increased, albeit not proportionally. For example, 80% of eyes with an MD loss of -2 dB/year would be detected after 3.3, 2.4, and 2.1 years when testing is performed once, twice, and thrice per year, respectively. For eyes with an MD loss of -0.5 dB/year, progression can be detected with 80% power after 7.3, 5.7, and 5.0 years, respectively. This study provides information on the time required to detect progression using MD trend analysis in glaucoma eyes when different testing frequencies are used. The smaller gains in the time to detect progression when testing is increased from twice to thrice per year suggests that obtaining 2 reliable tests at baseline followed by semiannual testing and confirmation of progression through repeat testing in the initial years of follow-up may provide a good compromise for detecting progression, while minimizing the burden on health care resources in clinical practice. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Lacerda, Eliza Maria da Costa Brito; Lima, Monica Gomes; Rodrigues, Anderson Raiol; Teixeira, Cláudio Eduardo Correa; de Lima, Lauro José Barata; Ventura, Dora Fix; Silveira, Luiz Carlos de Lima
2012-01-01
The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction. PMID:22220188
The visual detection of driving while intoxicated : field test of visual cues and detection methods
DOT National Transportation Integrated Search
1980-04-01
A Drunk Driver Detection Guide was developed and tested at a sample of 10 law enforcement agencies at locations throughout the United States. The test was designed to provide both longitudinal and cross-sectional analyses of several measures likely t...
Unilateral pigmentary retinopathy--a review of literature and case presentation.
Stamate, Alina-Cristina; Burcea, Marian; Zemba, Mihail
2016-01-01
To report a rare case of unilateral pigmentary retinopathy and describe the clinical and visual field characteristics of this particular case. We present the case of a 30-year-old male patient with a gradual loss of the visual field on his left eye (LE) for the past 10 years, with further gradual painless loss of his central visual field in the last year, and no similar symptoms in his right eye. His past medical and ocular history were unremarkable. No family history of acquired or inherited diseases was determined. Based on the history, clinical findings, and visual field examination, the diagnosis of unilateral pigmentary retinopathy was established. Visual acuity and visual field in the left eye (LE) were severely affected, while in the right eye (RE), they were completely normal. In this case, distinct features of pigmentary retinopathy were observed only in one eye, with the fellow eye being unaffected. The diagnosis requires a long follow-up period, visual field and electrophysiological testing to rule out a delayed onset of a bilateral form of pigmentary retinopathy.
Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos
2009-01-01
Purpose: To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. Methods: In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 ± 0.6 years). Color vision defects were studied using a special computer program for Farnsworth–Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30–2. Both tests were repeated every six months. Results: In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 ± 31.79) and OH eyes (75.51 ± 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was −20.62 ± 2.75 (t value 9.08, p < 0.001) while in OH eyes was −2.11 ± 4.36 (t value 1.1, p = 0.276). Pearson’s coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Conclusion: Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields. PMID:19668575
Aging and feature search: the effect of search area.
Burton-Danner, K; Owsley, C; Jackson, G R
2001-01-01
The preattentive system involves the rapid parallel processing of visual information in the visual scene so that attention can be directed to meaningful objects and locations in the environment. This study used the feature search methodology to examine whether there are aging-related deficits in parallel-processing capabilities when older adults are required to visually search a large area of the visual field. Like young subjects, older subjects displayed flat, near-zero slopes for the Reaction Time x Set Size function when searching over a broad area (30 degrees radius) of the visual field, implying parallel processing of the visual display. These same older subjects exhibited impairment in another task, also dependent on parallel processing, performed over the same broad field area; this task, called the useful field of view test, has more complex task demands. Results imply that aging-related breakdowns of parallel processing over a large visual field area are not likely to emerge when required responses are simple, there is only one task to perform, and there is no limitation on visual inspection time.
The effect of simulated altitude on the visual fields of glaucoma patients and the elderly.
DOT National Transportation Integrated Search
1991-01-01
This study tests whether mild hypoxia, that is typically encountered in civilian aircraft, causes temporary visual field defects in elderly persons or temporarily increases pre-existing defects in persons with glaucoma. The central 24-2 program on th...
Application of virtual reality graphics in assessment of concussion.
Slobounov, Semyon; Slobounov, Elena; Newell, Karl
2006-04-01
Abnormal balance in individuals suffering from traumatic brain injury (TBI) has been documented in numerous recent studies. However, specific mechanisms causing balance deficits have not been systematically examined. This paper demonstrated the destabilizing effect of visual field motion, induced by virtual reality graphics in concussed individuals but not in normal controls. Fifty five student-athletes at risk for concussion participated in this study prior to injury and 10 of these subjects who suffered MTBI were tested again on day 3, day 10, and day 30 after the incident. Postural responses to visual field motion were recorded using a virtual reality (VR) environment in conjunction with balance (AMTI force plate) and motion tracking (Flock of Birds) technologies. Two experimental conditions were introduced where subjects passively viewed VR scenes or actively manipulated the visual field motion. Long-lasting destabilizing effects of visual field motion were revealed, although subjects were asymptomatic when standard balance tests were introduced. The findings demonstrate that advanced VR technology may detect residual symptoms of concussion at least 30 days post-injury.
High speed digital holographic interferometry for hypersonic flow visualization
NASA Astrophysics Data System (ADS)
Hegde, G. M.; Jagdeesh, G.; Reddy, K. P. J.
2013-06-01
Optical imaging techniques have played a major role in understanding the flow dynamics of varieties of fluid flows, particularly in the study of hypersonic flows. Schlieren and shadowgraph techniques have been the flow diagnostic tools for the investigation of compressible flows since more than a century. However these techniques provide only the qualitative information about the flow field. Other optical techniques such as holographic interferometry and laser induced fluorescence (LIF) have been used extensively for extracting quantitative information about the high speed flows. In this paper we present the application of digital holographic interferometry (DHI) technique integrated with short duration hypersonic shock tunnel facility having 1 ms test time, for quantitative flow visualization. Dynamics of the flow fields in hypersonic/supersonic speeds around different test models is visualized with DHI using a high-speed digital camera (0.2 million fps). These visualization results are compared with schlieren visualization and CFD simulation results. Fringe analysis is carried out to estimate the density of the flow field.
Hou, X R; Qin, J Y; Ren, Z Q
2017-02-11
Objective: To investigate the rationality of visual field morphological stages of glaucoma, its relationship with visual field index and their diagnostic value. Methods: Retrospective series case study. Two hundred and seventy-four glaucoma patients and 100 normal control received visual field examination by Humphrey perimeter using standard automatic perimetry (SAP) program from March 2014 to September 2014. Glaucoma patients were graded into four stages according to characteristic morphological damage of visual field, distribution of mean defect (MD) and visual field index (VFI) of each stage were plotted and receiver operation characteristic curve (ROC) was used to explore its correlation with MD and VFI. The diagnostic value of MD and VFI was also compared. For the comparison of general data of subjects, categorical variables were compared using χ(2) test, numerical variables were compared using F test. MD and VFI were compared using ANOVA among stages according to visual field, followed by multiple comparisons using LSD method. The correlation between MD and VFI and different stages according to visual field defined their diagnostic value, and compared using area under the curve (AUC) of ROC. Results: No characteristic visual field damage was found in normal control group, and MD and VFI was (-0.06±1.24) dB and (99.15±0.76)%, respectively. Glaucomatous visual field damage was graded into early, medium, late and end stage according to morphological characteristic. MD for each stage were (-2.83±2.00) dB, (-9.70±3.68) dB, (-18.46±2.90) dB, and (-27.96±2.76) dB, respectively. VFI for each stage were (93.84±3.61)%, (75.16±10.85)%, (49.36±11.26)% and (17.65±10.59)%, respectively. MD and VFI of each stage of glaucomatous group and normal control group were all significantly different ( F= 1 165.53 and P <0.01 for MD; F= 1 028.04 and P <0.01 for VFI). AUC of ROC was A(MD)=0.91 and Se(MD)=0.01 (95% confident interval was 0.89-0.94) for MD, and A(VFI)=0.97, Se(VFI)=0.01 (95% confident interval was 0.94-0.10) for VFI. So, AUC(VFI)>AUC(MD) ( P< 0.05). Conclusions: It is feasible and rational of glaucomatous visual field damage to be graded into early, medium, late and end stage using Humphrey perimeter. Distribution of MD and VFI for each stage was relatively concentrative. Both MD and VFI were useful for grading glaucomatous visual field damage with preference for VFI. (Chin J Ophthalmol, 2017, 53: 92-97) .
Mobility scooter driving ability in visually impaired individuals.
Cordes, Christina; Heutink, Joost; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M
2018-06-01
To investigate how well visually impaired individuals can learn to use mobility scooters and which parts of the driving task deserve special attention. A mobility scooter driving skill test was developed to compare driving skills (e.g. reverse driving, turning) between 48 visually impaired (very low visual acuity = 14, low visual acuity = 10, peripheral field defects = 11, multiple visual impairments = 13) and 37 normal-sighted controls without any prior experience with mobility scooters. Performance on this test was rated on a three-point scale. Furthermore, the number of extra repetitions on the different elements were noted. Results showed that visually impaired participants were able to gain sufficient driving skills to be able to use mobility scooters. Participants with visual field defects combined with low visual acuity showed most problems learning different skills and needed more training. Reverse driving and stopping seemed to be most difficult. The present findings suggest that visually impaired individuals are able to learn to drive mobility scooters. Mobility scooter allocators should be aware that these individuals might need more training on certain elements of the driving task. Implications for rehabilitation Visual impairments do not necessarily lead to an inability to acquire mobility scooter driving skills. Individuals with peripheral field defects (especially in combination with reduced visual acuity) need more driving ability training compared to normal-sighted people - especially to accomplish reversing. Individual assessment of visually impaired people is recommended, since participants in this study showed a wide variation in ability to learn driving a mobility scooter.
Solar retinopathy. A study from Nepal and from Germany.
Rai, N; Thuladar, L; Brandt, F; Arden, G B; Berninger, T A
1998-01-01
319 patients with a solar retinopathy were seen in an eye clinic in Nepal within 20 months. All patients had either a positive history of sun-gazing or typical circumscribed scars in the foveal area. In more than 80% of the patients the visual acuity was 6/12 or better and did not deteriorate over time. 126 (40%) patients had a history of gazing at the sun during an eclipse, 33 (10%) were sun worshipers and 4 (1%) were in both categories. Three years later 29 patients were re-examined in a follow-up study. Only 16 had had visual disturbances directly after they had gazed into the sun. No colour vision defects were seen in any of the 44 affected eyes, when tested with Panel D 15, while four patients (6 eyes) had some uncertainty with the tritan plates of the Ishihara test charts. Metamorphopsia were recorded in 11 eyes. Five German patients with solar retinopathy were examined in more detail. Colour contrast sensitivity (CCS) was tested for the central and the peripheral visual field. CCS for tritan axis was raised in all patients for the central visual field, while it was normal for the peripheral visual field.
Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.
Teoh, S L; Allan, D; Dutton, G N; Foulds, W S
1990-01-01
The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma. PMID:2186795
Flow visualization methods for field test verification of CFD analysis of an open gloveport
Strons, Philip; Bailey, James L.
2017-01-01
Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measuredmore » relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.« less
A Portable Platform for Evaluation of Visual Performance in Glaucoma Patients
Rosen, Peter N.; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Marvasti, Amir H.; Medeiros, Felipe A.
2015-01-01
Purpose To propose a new tablet-enabled test for evaluation of visual performance in glaucoma, the PERformance CEntered Portable Test (PERCEPT), and to evaluate its ability to predict history of falls and motor vehicle crashes. Design Cross-sectional study. Methods The study involved 71 patients with glaucomatous visual field defects on standard automated perimetry (SAP) and 59 control subjects. The PERCEPT was based on the concept of increasing visual task difficulty to improve detection of central visual field losses in glaucoma patients. Subjects had to perform a foveal 8-alternative-forced-choice orientation discrimination task, while detecting a simultaneously presented peripheral stimulus within a limited presentation time. Subjects also underwent testing with the Useful Field of View (UFOV) divided attention test. The ability to predict history of motor vehicle crashes and falls was investigated by odds ratios and incident-rate ratios, respectively. Results When adjusted for age, only the PERCEPT processing speed parameter showed significantly larger values in glaucoma compared to controls (difference: 243ms; P<0.001). PERCEPT results had a stronger association with history of motor vehicle crashes and falls than UFOV. Each 1 standard deviation increase in PERCEPT processing speed was associated with an odds ratio of 2.69 (P = 0.003) for predicting history of motor vehicle crashes and with an incident-rate ratio of 1.95 (P = 0.003) for predicting history of falls. Conclusion A portable platform for testing visual function was able to detect functional deficits in glaucoma, and its results were significantly associated with history of involvement in motor vehicle crashes and history of falls. PMID:26445501
Field Dependence, Perceptual Instability, and Sex Differences.
ERIC Educational Resources Information Center
Bergum, Judith E.; Bergum, Bruce O.
Recent studies have shown perceptual instability to be related to visual creativity as reflected in career choice. In general, those who display greater perceptual instability perceive themselves to be more creative and tend to choose careers related to visual creativity, regardless of their gender. To test the hypothesis that field independents…
A low-cost and versatile system for projecting wide-field visual stimuli within fMRI scanners
Greco, V.; Frijia, F.; Mikellidou, K.; Montanaro, D.; Farini, A.; D’Uva, M.; Poggi, P.; Pucci, M.; Sordini, A.; Morrone, M. C.; Burr, D. C.
2016-01-01
We have constructed and tested a custom-made magnetic-imaging-compatible visual projection system designed to project on a very wide visual field (~80°). A standard projector was modified with a coupling lens, projecting images into the termination of an image fiber. The other termination of the fiber was placed in the 3-T scanner room with a projection lens, which projected the images relayed by the fiber onto a screen over the head coil, viewed by a participant wearing magnifying goggles. To validate the system, wide-field stimuli were presented in order to identify retinotopic visual areas. The results showed that this low-cost and versatile optical system may be a valuable tool to map visual areas in the brain that process peripheral receptive fields. PMID:26092392
Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.
Gardiner, Stuart K; Swanson, William H; Goren, Deborah; Mansberger, Steven L; Demirel, Shaban
2014-07-01
Visual field testing uses high-contrast stimuli in areas of severe visual field loss. However, retinal ganglion cells saturate with high-contrast stimuli, suggesting that the probability of detecting perimetric stimuli may not increase indefinitely as contrast increases. Driven by this concept, this study examines the lower limit of perimetric sensitivity for reliable testing by standard automated perimetry. Evaluation of a diagnostic test. A total of 34 participants with moderate to severe glaucoma; mean deviation at their last clinic visit averaged -10.90 dB (range, -20.94 to -3.38 dB). A total of 75 of the 136 locations tested had a perimetric sensitivity of ≤ 19 dB. Frequency-of-seeing curves were constructed at 4 nonadjacent visual field locations by the Method of Constant Stimuli (MOCS), using 35 stimulus presentations at each of 7 contrasts. Locations were chosen a priori and included at least 2 with glaucomatous damage but a sensitivity of ≥ 6 dB. Cumulative Gaussian curves were fit to the data, first assuming a 5% false-negative rate and subsequently allowing the asymptotic maximum response probability to be a free parameter. The strength of the relation (R(2)) between perimetric sensitivity (mean of last 2 clinic visits) and MOCS sensitivity (from the experiment) for all locations with perimetric sensitivity within ± 4 dB of each selected value, at 0.5 dB intervals. Bins centered at sensitivities ≥ 19 dB always had R(2) >0.1. All bins centered at sensitivities ≤ 15 dB had R(2) <0.1, an indication that sensitivities are unreliable. No consistent conclusions could be drawn between 15 and 19 dB. At 57 of the 81 locations with perimetric sensitivity <19 dB, including 49 of the 63 locations ≤ 15 dB, the fitted asymptotic maximum response probability was <80%, consistent with the hypothesis of response saturation. At 29 of these locations the asymptotic maximum was <50%, and so contrast sensitivity (50% response rate) is undefined. Clinical visual field testing may be unreliable when visual field locations have sensitivity below approximately 15 to 19 dB because of a reduction in the asymptotic maximum response probability. Researchers and clinicians may have difficulty detecting worsening sensitivity in these visual field locations, and this difficulty may occur commonly in patients with glaucoma with moderate to severe glaucomatous visual field loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Word learning and the cerebral hemispheres: from serial to parallel processing of written words
Ellis, Andrew W.; Ferreira, Roberto; Cathles-Hagan, Polly; Holt, Kathryn; Jarvis, Lisa; Barca, Laura
2009-01-01
Reading familiar words differs from reading unfamiliar non-words in two ways. First, word reading is faster and more accurate than reading of unfamiliar non-words. Second, effects of letter length are reduced for words, particularly when they are presented in the right visual field in familiar formats. Two experiments are reported in which right-handed participants read aloud non-words presented briefly in their left and right visual fields before and after training on those items. The non-words were interleaved with familiar words in the naming tests. Before training, naming was slow and error prone, with marked effects of length in both visual fields. After training, fewer errors were made, naming was faster, and the effect of length was much reduced in the right visual field compared with the left. We propose that word learning creates orthographic word forms in the mid-fusiform gyrus of the left cerebral hemisphere. Those word forms allow words to access their phonological and semantic representations on a lexical basis. But orthographic word forms also interact with more posterior letter recognition systems in the middle/inferior occipital gyri, inducing more parallel processing of right visual field words than is possible for any left visual field stimulus, or for unfamiliar non-words presented in the right visual field. PMID:19933140
Effects of Peripheral Visual Field Loss on Eye Movements During Visual Search
Wiecek, Emily; Pasquale, Louis R.; Fiser, Jozsef; Dakin, Steven; Bex, Peter J.
2012-01-01
Natural vision involves sequential eye movements that bring the fovea to locations selected by peripheral vision. How peripheral visual field loss (PVFL) affects this process is not well understood. We examine how the location and extent of PVFL affects eye movement behavior in a naturalistic visual search task. Ten patients with PVFL and 13 normally sighted subjects with full visual fields (FVF) completed 30 visual searches monocularly. Subjects located a 4° × 4° target, pseudo-randomly selected within a 26° × 11° natural image. Eye positions were recorded at 50 Hz. Search duration, fixation duration, saccade size, and number of saccades per trial were not significantly different between PVFL and FVF groups (p > 0.1). A χ2 test showed that the distributions of saccade directions for PVFL and FVL subjects were significantly different in 8 out of 10 cases (p < 0.01). Humphrey Visual Field pattern deviations for each subject were compared with the spatial distribution of eye movement directions. There were no significant correlations between saccade directional bias and visual field sensitivity across the 10 patients. Visual search performance was not significantly affected by PVFL. An analysis of eye movement directions revealed patients with PVFL show a biased directional distribution that was not directly related to the locus of vision loss, challenging feed-forward models of eye movement control. Consequently, many patients do not optimally compensate for visual field loss during visual search. PMID:23162511
Visual impairment in Finnish Usher syndrome type III.
Plantinga, Rutger F; Pennings, Ronald J E; Huygen, Patrick L M; Sankila, Eeva-Marja; Tuppurainen, Kaija; Kleemola, Leenamaija; Cremers, Cor W R J; Deutman, August F
2006-02-01
To evaluate visual impairment in Finnish Usher syndrome type 3 (USH3) and compare this with visual impairment in Usher syndrome types 1b (USH1b) and 2a (USH2a). We carried out a retrospective study of 28 Finnish USH3 patients, 24 Dutch USH2a patients and 17 Dutch USH1b patients. Cross-sectional regression analyses of the functional acuity score (FAS), functional field score (FFS*) and functional vision score (FVS*) related to age were performed for all patients. The FFS* and FVS* were calculated using the isoptre V-4 test target instead of the usual III-4 target. Statistical tests relating to regression lines and Student's t-test were used to compare between USH3 patients and the other genetic subtypes of Usher syndrome. Cross-sectional analyses revealed significant deterioration in the FAS (1.3% per year), FFS* (1.4% per year) and FVS* (1.8% per year) with advancing age in the USH3 patient group. At a given age the USH3 patients showed significantly poorer visual field function than the USH2a patients. The rate of deterioration in visual function in Finnish USH3 patients was fairly similar to that in Dutch USH1b or USH2a patients. At a given age, visual field impairment in USH3 patients was similar to that in USH1b patients but poorer than in USH2a patients.
Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F
2018-03-11
Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .
Medical review licensing outcomes in drivers with visual field loss in Victoria, Australia
Muir, Carlyn; Charlton, Judith L; Odell, Morris; Keeffe, Jill; Wood, Joanne; Bohensky, Megan; Fildes, Brian; Oxley, Jennifer; Bentley, Sharon; Rizzo, Matthew
2017-01-01
Background Good vision is essential for safe driving and studies have associated visual impairment with an increased crash risk. Currently, there is little information about the medical review of drivers with visual field loss. This study examines the prevalence of visual field loss among drivers referred for medical review in one Australian jurisdiction and investigates factors associated with licence outcome in this group. Methods A random sample of 10,000 (31.25 per cent) medical review cases was extracted for analysis from the Victorian licensing authority. Files were screened for the presence of six visual field-related medical conditions. Data were captured on a range of variables, including referral source, age, gender, health status, crash history and licence outcome. Prevalence analyses were univariate and descriptive. Logistic regression was used to assess factors associated with licence outcomes in the visual field loss group. Results Approximately 1.9 per cent of the 10,000 medical review cases screened had a visual field loss condition identified (n=194). Among the visual field loss group, 57.2 per cent were permitted to continue driving (conditional/unconditional licence). Primary referral sources were the police, self-referrals and general medical practitioners. Key factors associated with licence test outcomes were visual field condition, age group, crash involvement and referral to the Driver Licensing Authority’s Medical Advisors. Those who were younger had a crash involvement triggering referral and those who were referred to the Medical Advisors were more likely to have a positive licensing outcome. Conclusion The evidence base for making licensing decisions is complicated by the variable causes, patterns, progressions and measuring technologies for visual field loss. This study highlighted that the involvement of an expert medical advisory service in Victoria resulted in an increased likelihood that drivers with visual field loss will be allowed to continue driving. Further research is warranted to explore issues relating to severity of field loss and the capacity for compensation. PMID:27530283
Satgunam, PremNandhini; Datta, Sourav; Chillakala, Koteswararao; Bobbili, Karthik R; Joshi, Dhruv
2017-07-01
There are no commercially available devices to measure visual fields in infants. We developed a device, "Pediatric Perimeter," that quantifies visual field extent (VFE) for infants. We describe the construction, validation, and use of this device. A hemispherical dome with light emitting diodes (LEDs) was constructed. The LEDs were controlled using a computer program to measure reaction time (RT) to gross visual fields (GVF) and the VFE. Participants were tested in supine position in a dark room. Eye or head movement towards the stimuli was monitored with an infrared (IR) camera. Validation was done on 10 adults (mean age: 24.4 ± 5 years) with tunnel vision simulator. Perimetry was performed on 19 infants (age: 2.3-12 months), five infants with normal milestones. GVF and VFE were estimated in 17 and 7 infants, respectively. Median RT of infants with developmental delay was 663 ms and 380 ms for healthy infants. Also, 14 children (age: 14 months-6 years) with developmental delay and five patients with cognitive impairment were tested. Visual field isopter and RT can be examined with the Pediatric Perimeter device on infants and patients with special needs. Further testing on infants will need to assess the repeatability. A large-scale study will be needed to compare typically developing infants and infants with delayed milestones with this device. Quantifiable parameters obtained with this device can be used as outcome measures in clinical examination of infants and patients with special needs. This device can be used in pediatric, neurology, and ophthalmology clinics.
The ability of healthy volunteers to simulate a neurologic field defect on automated perimetry.
Ghate, Deepta; Bodnarchuk, Brian; Sanders, Sheila; Deokule, Sunil; Kedar, Sachin
2014-03-01
To determine if volunteers can simulate and reproduce 3 types of neurologic field defects: hemianopia, quadrantanopia, and central scotoma. Cross-sectional study. Thirty healthy volunteers new to perimetry (including automated perimetry). After informed consent, volunteers were randomized to 1 of the 3 visual field defects listed above. All visual field testing was performed on the right eye using the Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA) SITA Fast 24-2 protocol. Each volunteer was provided with standard new patient instructions and was shown a diagram of the defect to be simulated. Two sets of visual fields were performed on the right eye with 10 minutes between tests. Three experts used the Ocular Hypertension Treatment Study reading center criteria and determined if the simulation was successful. Proportion of volunteers able to simulate the assigned visual field. All 10 volunteers (100%) successfully simulated a hemianopia on the first and second fields. All 10 volunteers (100%) simulated a quadrantanopia on the first field and 9 (90%) did so on the second field. Eight volunteers (80%) successfully simulated a central scotoma in the first field and all 10 (100%) did so on in the second field. Reliability criteria were excellent. Forty-seven fields (78%) had 0 fixation losses, 48 (80%) had 0 false-positive results, and 44 (73%) had 0 false-negative results. It is easy to simulate reproducible and reliable neurologic field defects on automated perimetry using HFA. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Left hemispheric advantage for numerical abilities in the bottlenose dolphin.
Kilian, Annette; von Fersen, Lorenzo; Güntürkün, Onur
2005-02-28
In a two-choice discrimination paradigm, a bottlenose dolphin discriminated relational dimensions between visual numerosity stimuli under monocular viewing conditions. After prior binocular acquisition of the task, two monocular test series with different number stimuli were conducted. In accordance with recent studies on visual lateralization in the bottlenose dolphin, our results revealed an overall advantage of the right visual field. Due to the complete decussation of the optic nerve fibers, this suggests a specialization of the left hemisphere for analysing relational features between stimuli as required in tests for numerical abilities. These processes are typically right hemisphere-based in other mammals (including humans) and birds. The present data provide further evidence for a general right visual field advantage in bottlenose dolphins for visual information processing. It is thus assumed that dolphins possess a unique functional architecture of their cerebral asymmetries. (c) 2004 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Danehy, Paul M.; Ivey, Christoper B.; Barthel, Brett F.; Inman, Jennifer A.; Jones, Stephen B.; Watkins, Anthony N.; Goodman, Kyle Z.; McCrea, Andrew C.; Leighty, Bradley D.; Lipford, William K.;
2010-01-01
This paper reports a series of wind tunnel tests simulating the near-field behavior of the Space Shuttle Orbiter Boundary Layer Transition Detailed Test Objective (BLT DTO) flight experiment. Hypersonic flow over a flat plate with an attached BLT DTO-shaped trip was tested in a Mach 10 wind tunnel. The sharp-leading-edge flat plate was oriented at an angle of 20 degrees with respect to the freestream flow, resulting in post-shock edge Mach number of approximately 4. The flowfield was visualized using nitric oxide (NO) planar laser-induced fluorescence (PLIF). Flow visualizations were performed at 10 Hz using a wide-field of view and high-resolution NO PLIF system. A lower spatial resolution and smaller field of view NO PLIF system visualized the flow at 500 kHz, which was fast enough to resolve unsteady flow features. At the lowest Reynolds number studied, the flow was observed to be laminar and mostly steady. At the highest Reynolds number, flow visualizations showed streak instabilities generated immediately downstream of the trip. These instabilities transitioned to unsteady periodic and spatially irregular structures downstream. Quantitative surface heating imagery was obtained using the Temperature Sensitive Paint (TSP) technique. Comparisons between the PLIF flow visualizations and TSP heating measurements show a strong correlation between flow patterns and surface heating trends.
Enhanced visualization of acute macular neuroretinopathy by Heidelberg Retina Tomography.
Mirshahi, Alireza; Scharioth, Gàbor B; Klais, Christina M C; Baatz, Holger
2006-08-01
We report Heidelberg Retina Tomography (HRT) findings in a case of bilateral acute macular neuroretinopathy in a 22-year-old man. In addition to fundus photography, fluorescein and indocyanine green angiography, and visual field testing, HRT scans of the macula were performed early in the disease and at a follow up of 2 months. We found typical paracentral scotomata in visual field testing corresponding to sharply delineated, hyporeflective areas of the macula as visualized in HRT II scans. Those lesions were almost invisible on regular fundus photographs. Angiography results were unremarkable. The lesion size decreased over time. The visibility of the lesions was markedly enhanced by HRT scans, thus the diagnosis and follow up of acute macular neuroretinopathy could be facilitated by this non-invasive imaging technique.
Use of subjective and objective criteria to categorise visual disability.
Kajla, Garima; Rohatgi, Jolly; Dhaliwal, Upreet
2014-04-01
Visual disability is categorised using objective criteria. Subjective measures are not considered. To use subjective criteria along with objective ones to categorise visual disability. Ophthalmology out-patient department; teaching hospital; observational study. Consecutive persons aged >25 years, with vision <20/20 (in one or both eyes) due to chronic conditions, like cataract and refractive errors, were categorized into 11 groups of increasing disability; group-zero: normal range of vision, to group-X: no perception of light, bilaterally. Snellen's vision; binocular contrast sensitivity (Pelli-Robson chart); automated binocular visual field (Humphrey; Esterman test); and vision-related quality of life (Indian Visual Function Questionnaire-33; IND-VFQ33) were recorded. SPSS version-17; Kruskal-wallis test was used to compare contrast sensitivity and visual fields across groups, and Mann-Whitney U test for pair-wise comparison (Bonferroni adjustment; P < 0.01). One-way ANOVA compared quality of life data across groups; for pairwise significance, Dunnett T3 test was applied. In 226 patients, contrast sensitivity and visual fields were comparable for differing disability grades except when disability was severe (P < 0.001), or moderately severe (P < 0.01). Individual scales of IND-VFQ33 were also mostly comparable; however, global scores showed a distinct pattern, being different for some disability grades but comparable for groups III (78.51 ± 6.86) and IV (82.64 ± 5.80), and groups IV and V (77.23 ± 3.22); these were merged to generate group 345; similarly, global scores were comparable for adjacent groups V and VI (72.53 ± 6.77), VI and VII (74.46 ± 4.32), and VII and VIII (69.12 ± 5.97); these were merged to generate group 5678; thereafter, contrast sensitivity and global and individual IND-VFQ33 scores could differentiate between different grades of disability in the five new groups. Subjective criteria made it possible to objectively reclassify visual disability. Visual disability grades could be redefined to accommodate all from zero-100%.
Wide-Field Fundus Autofluorescence for Retinitis Pigmentosa and Cone/Cone-Rod Dystrophy.
Oishi, Akio; Oishi, Maho; Ogino, Ken; Morooka, Satoshi; Yoshimura, Nagahisa
2016-01-01
Retinitis pigmentosa and cone/cone-rod dystrophy are inherited retinal diseases characterized by the progressive loss of rod and/or cone photoreceptors. To evaluate the status of rod/cone photoreceptors and visual function, visual acuity and visual field tests, electroretinogram, and optical coherence tomography are typically used. In addition to these examinations, fundus autofluorescence (FAF) has recently garnered attention. FAF visualizes the intrinsic fluorescent material in the retina, which is mainly lipofuscin contained within the retinal pigment epithelium. While conventional devices offer limited viewing angles in FAF, the recently developed Optos machine enables recording of wide-field FAF. With wide-field analysis, an association between abnormal FAF areas and visual function was demonstrated in retinitis pigmentosa and cone-rod dystrophy. In addition, the presence of "patchy" hypoautofluorescent areas was found to be correlated with symptom duration. Although physicians should be cautious when interpreting wide-field FAF results because the peripheral parts of the image are magnified significantly, this examination method provides previously unavailable information.
Hemispheric asymmetries of a motor memory in a recognition test after learning a movement sequence.
Leinen, Peter; Panzer, Stefan; Shea, Charles H
2016-11-01
Two experiments utilizing a spatial-temporal movement sequence were designed to determine if the memory of the sequence is lateralized in the left or right hemisphere. In Experiment 1, dominant right-handers were randomly assigned to one of two acquisition groups: a left-hand starter and a right-hand starter group. After an acquisition phase, reaction time (RT) was measured in a recognition test by providing the learned sequential pattern in the left or right visual half-field for 150ms. In a retention test and two transfer tests the dominant coordinate system for sequence production was evaluated. In Experiment 2 dominant left-handers and dominant right-handers had to acquire the sequence with their dominant limb. The results of Experiment 1 indicated that RT was significantly shorter when the acquired sequence was provided in the right visual field during the recognition test. The same results occurred in Experiment 2 for dominant right-handers and left-handers. These results indicated a right visual field left hemisphere advantage in the recognition test for the practiced stimulus for dominant left and right-handers, when the task was practiced with the dominant limb. Copyright © 2016 Elsevier B.V. All rights reserved.
Using a Self-Administered Visual Basic Software Tool To Teach Psychological Concepts.
ERIC Educational Resources Information Center
Strang, Harold R.; Sullivan, Amie K.; Schoeny, Zahrl G.
2002-01-01
Introduces LearningLinks, a Visual Basic software tool that allows teachers to create individualized learning modules that use constructivist and behavioral learning principles. Describes field testing of undergraduates at the University of Virginia that tested a module designed to improve understanding of the psychological concepts of…
A new measure for the assessment of visual awareness in individuals with tunnel vision.
AlSaqr, Ali M; Dickinson, Chris M
2017-01-01
Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.
Kothari, Ruchi; Bokariya, Pradeep; Singh, Ramji; Singh, Smita; Narang, Purvasha
2014-01-01
To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation (PSD) of Humphrey visual field could be associated with visual evoked potential (VEP) parameters of patients having primary open angle glaucoma (POAG). Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential (PRVEP) were assessed in 100 patients with POAG. The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated (full field) and displayed on VEP monitor (colour 14″) by an electronic pattern regenerator inbuilt in an evoked potential recorder (RMS EMG EP MARK II). The results of our study indicate that there is a highly significant (P<0.001) negative correlation of P100 amplitude and a statistically significant (P<0.05) positive correlation of N70 latency, P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student's t-test. Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values. Conversely, as PSD increases the magnitude of VEP excursions were found to be diminished.
Kasten, Erich; Bunzenthal, Ulrike; Sabel, Bernhard A
2006-11-25
It has been argued that patients with visual field defects compensate for their deficit by making more frequent eye movements toward the hemianopic field and that visual field enlargements found after vision restoration therapy (VRT) may be an artefact of such eye movements. In order to determine if this was correct, we recorded eye movements in hemianopic subjects before and after VRT. Visual fields were measured in subjects with homonymous visual field defects (n=15) caused by trauma, cerebral ischemia or haemorrhage (lesion age >6 months). Visual field charts were plotted using both high-resolution perimetry (HRP) and conventional perimetry before and after a 3-month period of VRT, with eye movements being recorded with a 2D-eye tracker. This permitted quantification of eye positions and measurements of deviation from fixation. VRT lead to significant visual field enlargements as indicated by an increase of stimulus detection of 3.8% when tested using HRP and about 2.2% (OD) and 3.5% (OS) fewer misses with conventional perimetry. Eye movements were expressed as the standard deviations (S.D.) of the eye position recordings from fixation. Before VRT, the S.D. was +/-0.82 degrees horizontally and +/-1.16 degrees vertically; after VRT, it was +/-0.68 degrees and +/-1.39 degrees , respectively. A cluster analysis of the horizontal eye movements before VRT showed three types of subjects with (i) small (n=7), (ii) medium (n=7) or (iii) large fixation instability (n=1). Saccades were directed equally to the right or the left side; i.e., with no preference toward the blind hemifield. After VRT, many subjects showed a smaller variability of horizontal eye movements. Before VRT, 81.6% of the recorded eye positions were found within a range of 1 degrees horizontally from fixation, whereas after VRT, 88.3% were within that range. In the 2 degrees range, we found 94.8% before and 98.9% after VRT. Subjects moved their eyes 5 degrees or more 0.3% of the time before VRT versus 0.1% after VRT. Thus, in this study, subjects with homonymous visual field defects who were attempting to fixate a central target while their fields were being plotted, typically showed brief horizontal shifts with no preference toward or away from the blind hemifield. These eye movements were usually less than 1 degrees from fixation. Large saccades toward the blind field after VRT were very rare. VRT has no effect on either the direction or the amplitude of horizontal eye movements during visual field testing. These results argue against the theory that the visual field enlargements are artefacts induced by eye movements.
Developing a Very Low Vision Orientation and Mobility Test Battery (O&M-VLV).
Finger, Robert P; Ayton, Lauren N; Deverell, Lil; O'Hare, Fleur; McSweeney, Shane C; Luu, Chi D; Fenwick, Eva K; Keeffe, Jill E; Guymer, Robyn H; Bentley, Sharon A
2016-09-01
This study aimed to determine the feasibility of an assessment of vision-related orientation and mobility (O&M) tasks in persons with severe vision loss. These tasks may be used for future low vision rehabilitation clinical assessments or as outcome measures in vision restoration trials. Forty legally blind persons (mean visual acuity logMAR 2.3, or hand movements) with advanced retinitis pigmentosa participated in the Orientation & Mobility-Very Low Vision (O&M-VLV) subtests from the Low Vision Assessment of Daily Activities (LoVADA) protocol. Four categories of tasks were evaluated: route travel in three indoor hospital environments, a room orientation task (the "cafe"), a visual exploration task (the "gallery"), and a modified version of the Timed Up and Go (TUG) test, which assesses re-orientation and route travel. Spatial cognition was assessed using the Stuart Tactile Maps test. Visual acuity and visual fields were measured. A generalized linear regression model showed that a number of measures in the O&M-VLV tasks were related to residual visual function. The percentage of preferred walking speed without an aid on three travel routes was associated with visual field (p < 0.01 for all routes) whereas the number of contacts with obstacles during route travel was associated with acuity (p = 0.001). TUG-LV task time was associated with acuity (p = 0.003), as was the cafe time and distance traveled (p = 0.006 and p < 0.001, respectively). The gallery score was the only measure that was significantly associated with both residual acuity and fields (p < 0.001 and p = 0.001, respectively). The O&M-VLV was designed to capture key elements of O&M performance in persons with severe vision loss, which is a population not often studied previously. Performance on these tasks was associated with both binocular visual acuity and visual field. This new protocol includes assessments of orientation, which may be of benefit in vision restoration clinical trials.
Do reference surfaces influence exocentric pointing?
Doumen, M J A; Kappers, A M L; Koenderink, J J
2008-06-01
All elements of the visual field are known to influence the perception of the egocentric distances of objects. Not only the ground surface of a scene, but also the surface at the back or other objects in the scene can affect an observer's egocentric distance estimation of an object. We tested whether this is also true for exocentric direction estimations. We used an exocentric pointing task to test whether the presence of poster-boards in the visual scene would influence the perception of the exocentric direction between two test-objects. In this task the observer has to direct a pointer, with a remote control, to a target. We placed the poster-boards at various positions in the visual field to test whether these boards would affect the settings of the observer. We found that they only affected the settings when they directly served as a reference for orienting the pointer to the target.
Evaluation of a combined index of optic nerve structure and function for glaucoma diagnosis
2011-01-01
Background The definitive diagnosis of glaucoma is currently based on congruent damage to both optic nerve structure and function. Given widespread quantitative assessment of both structure (imaging) and function (automated perimetry) in glaucoma, it should be possible to combine these quantitative data to diagnose disease. We have therefore defined and tested a new approach to glaucoma diagnosis by combining imaging and visual field data, using the anatomical organization of retinal ganglion cells. Methods Data from 1499 eyes of glaucoma suspects and 895 eyes with glaucoma were identified at a single glaucoma center. Each underwent Heidelberg Retinal Tomograph (HRT) imaging and standard automated perimetry. A new measure combining these two tests, the structure function index (SFI), was defined in 3 steps: 1) calculate the probability that each visual field point is abnormal, 2) calculate the probability of abnormality for each of the six HRT optic disc sectors, and 3) combine those probabilities with the probability that a field point and disc sector are linked by ganglion cell anatomy. The SFI was compared to the HRT and visual field using receiver operating characteristic (ROC) analysis. Results The SFI produced an area under the ROC curve (0.78) that was similar to that for both visual field mean deviation (0.78) and pattern standard deviation (0.80) and larger than that for a normalized measure of HRT rim area (0.66). The cases classified as glaucoma by the various tests were significantly non-overlapping. Based on the distribution of test values in the population with mild disease, the SFI may be better able to stratify this group while still clearly identifying those with severe disease. Conclusions The SFI reflects the traditional clinical diagnosis of glaucoma by combining optic nerve structure and function. In doing so, it identifies a different subset of patients than either visual field testing or optic nerve head imaging alone. Analysis of prospective data will allow us to determine whether the combined index of structure and function can provide an improved standard for glaucoma diagnosis. PMID:21314957
A water tunnel flow visualization study of the F-15
NASA Technical Reports Server (NTRS)
Lorincz, D. J.
1978-01-01
Water tunnel studies were performed to qualitatively define the flow field of the F-15 aircraft. Two lengthened forebodies, one with a modified cross-sectional shape, were tested in addition to the basic forebody. Particular emphasis was placed on defining vortex flows generated at high angles of attack. The flow visualization tests were conducted in the Northrop diagnostic water tunnel using a 1/48-scale model of the F-15. Flow visualization pictures were obtained over an angle-of-attack range to 55 deg and sideslip angles up to 10 deg. The basic aircraft configuration was investigated in detail to determine the vortex flow field development, vortex path, and vortex breakdown characteristics as a function of angle of attack and sideslip. Additional tests showed that the wing upper surface vortex flow fields were sensitive to variations in inlet mass flow ratio and inlet cowl deflection angle. Asymmetries in the vortex systems generated by each of the three forebodies were observed in the water tunnel at zero sideslip and high angles of attack.
Scene and human face recognition in the central vision of patients with glaucoma
Aptel, Florent; Attye, Arnaud; Guyader, Nathalie; Boucart, Muriel; Chiquet, Christophe; Peyrin, Carole
2018-01-01
Primary open-angle glaucoma (POAG) firstly mainly affects peripheral vision. Current behavioral studies support the idea that visual defects of patients with POAG extend into parts of the central visual field classified as normal by static automated perimetry analysis. This is particularly true for visual tasks involving processes of a higher level than mere detection. The purpose of this study was to assess visual abilities of POAG patients in central vision. Patients were assigned to two groups following a visual field examination (Humphrey 24–2 SITA-Standard test). Patients with both peripheral and central defects and patients with peripheral but no central defect, as well as age-matched controls, participated in the experiment. All participants had to perform two visual tasks where low-contrast stimuli were presented in the central 6° of the visual field. A categorization task of scene images and human face images assessed high-level visual recognition abilities. In contrast, a detection task using the same stimuli assessed low-level visual function. The difference in performance between detection and categorization revealed the cost of high-level visual processing. Compared to controls, patients with a central visual defect showed a deficit in both detection and categorization of all low-contrast images. This is consistent with the abnormal retinal sensitivity as assessed by perimetry. However, the deficit was greater for categorization than detection. Patients without a central defect showed similar performances to the controls concerning the detection and categorization of faces. However, while the detection of scene images was well-maintained, these patients showed a deficit in their categorization. This suggests that the simple loss of peripheral vision could be detrimental to scene recognition, even when the information is displayed in central vision. This study revealed subtle defects in the central visual field of POAG patients that cannot be predicted by static automated perimetry assessment using Humphrey 24–2 SITA-Standard test. PMID:29481572
Improvement in conduction velocity after optic neuritis measured with the multifocal VEP.
Yang, E Bo; Hood, Donald C; Rodarte, Chris; Zhang, Xian; Odel, Jeffrey G; Behrens, Myles M
2007-02-01
To test the efficacy of the multifocal visual evoked potential (mfVEP) technique after long-term latency changes in optic neuritis (ON)/multiple sclerosis (MS), mfVEPs were recorded in 12 patients with ON/MS. Sixty local VEP responses were recorded simultaneously. mfVEP was recorded from both eyes of 12 patients with ON/MS. Patients were tested twice after recovery from acute ON episodes, which occurred in 14 of the 24 eyes. After recovery, all eyes had 20/20 or better visual acuity and normal visual fields as measured with static automated perimetry (SAP). The time between the two postrecovery tests varied from 6 to 56 months. Between test days, the visual fields obtained with SAP remained normal. Ten of the 14 affected eyes showed improvement in median latency on the mfVEP. Six of these eyes fell at or below (improved latency) the 96% confidence interval for the control eyes. None of the 10 initially unaffected eyes fell below the 96% lower limit. Although the improvement was widespread across the field, it did not include all regions. For the six eyes showing clear improvement, on average, 78% of the points had latencies that were shorter on test 2 than on test 1. A substantial percentage of ON/MS patients show a long-term improvement in conduction velocity. Because this improvement can be local, the mfVEP should allow these improvements to be monitored in patients with ON/MS.
Visual discrimination training improves Humphrey perimetry in chronic cortically induced blindness.
Cavanaugh, Matthew R; Huxlin, Krystel R
2017-05-09
To assess if visual discrimination training improves performance on visual perimetry tests in chronic stroke patients with visual cortex involvement. 24-2 and 10-2 Humphrey visual fields were analyzed for 17 chronic cortically blind stroke patients prior to and following visual discrimination training, as well as in 5 untrained, cortically blind controls. Trained patients practiced direction discrimination, orientation discrimination, or both, at nonoverlapping, blind field locations. All pretraining and posttraining discrimination performance and Humphrey fields were collected with online eye tracking, ensuring gaze-contingent stimulus presentation. Trained patients recovered ∼108 degrees 2 of vision on average, while untrained patients spontaneously improved over an area of ∼16 degrees 2 . Improvement was not affected by patient age, time since lesion, size of initial deficit, or training type, but was proportional to the amount of training performed. Untrained patients counterbalanced their improvements with worsening of sensitivity over ∼9 degrees 2 of their visual field. Worsening was minimal in trained patients. Finally, although discrimination performance improved at all trained locations, changes in Humphrey sensitivity occurred both within trained regions and beyond, extending over a larger area along the blind field border. In adults with chronic cortical visual impairment, the blind field border appears to have enhanced plastic potential, which can be recruited by gaze-controlled visual discrimination training to expand the visible field. Our findings underscore a critical need for future studies to measure the effects of vision restoration approaches on perimetry in larger cohorts of patients. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
Grating test of contrast sensitivity in patients with Minamata disease.
Mukuno, K; Ishikawa, S; Okamura, R
1981-01-01
Thirty cases of Minamata disease caused by methyl mercury poisoning with the lesion mainly at the occipital cortex were selected and their spatial contrast sensitivity of vision was examined by the Arden grating chart. At the same time their visual acuity, visual field, and visual evoked cortical potential (VECP) were also investigated. In all cases the results of the Arden test indicated abnormality. Poor results were obtained at higher frequencies of the gratings. VECP elicited by grating pattern reversal stimulus was undertaken in 12 cases out of the 30. The results revealed abnormality almost equal to that shown by the Arden test. Seven out of the 12 cases showed no VECP response. The other 5, giving a response, showed abnormality: when the size of the grating became smaller at higher frequencies, the VECP paused or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement with the results of the Arden test. Visual acuity and visual field tests were less sensitive in detecting abnormality. The Arden chart is a sensitive clinical tool for patients with lesions at the cerebral cortex. Furthermore, the test can be used for screening patients who may have come in contrast with organic mercury. PMID:7236573
Fiori, Francesca; David, Nicole; Aglioti, Salvatore M
2014-01-01
In the rod and frame test (RFT), participants are asked to set a tilted visual linear marker (i.e., a rod), embedded in a square, to the subjective vertical, irrespective of the surrounding frame. People not influenced by the frame tilt are defined as field-independent, while people biased in their rod verticality perception are field-dependent. Performing RFT requires the integration of proprioceptive, vestibular and visual signals with the latter accounting for field-dependency. Studies indicate that motor experts in body-related, balance-improving disciplines tend to be field-independent, i.e., better at verticality perception, suggesting that proprioceptive and vestibular expertise acquired by such exercise may weaken the influence of irrelevant visual signals. What remains unknown is whether the effect of body-related expertise in weighting perceptual information might also be mediated by personality traits, in particular those indexing self-focusing abilities. To explore this issue, we tested field-dependency in a class of body experts, namely yoga practitioners and in non-expert participants. Moreover we explored any link between performance on RFT and self-transcendence (ST), a complex personality construct, which refers to tendency to experience spiritual feelings and ideas. As expected, yoga practitioners (i) were more accurate in assessing the rod's verticality on the RFT, and (ii) expressed significantly higher ST. Interestingly, the performance in these two tests was negatively correlated. More specifically, when asked to provide verticality judgments, highly self-transcendent yoga practitioners were significantly less influenced by a misleading visual context. Our results suggest that being highly self-transcendent may enable yoga practitioners to optimize verticality judgment tasks by relying more on internal (vestibular and proprioceptive) signals coming from their own body, rather than on exteroceptive, visual cues.
Fiori, Francesca; David, Nicole; Aglioti, Salvatore M.
2014-01-01
In the rod and frame test (RFT), participants are asked to set a tilted visual linear marker (i.e., a rod), embedded in a square, to the subjective vertical, irrespective of the surrounding frame. People not influenced by the frame tilt are defined as field-independent, while people biased in their rod verticality perception are field-dependent. Performing RFT requires the integration of proprioceptive, vestibular and visual signals with the latter accounting for field-dependency. Studies indicate that motor experts in body-related, balance-improving disciplines tend to be field-independent, i.e., better at verticality perception, suggesting that proprioceptive and vestibular expertise acquired by such exercise may weaken the influence of irrelevant visual signals. What remains unknown is whether the effect of body-related expertise in weighting perceptual information might also be mediated by personality traits, in particular those indexing self-focusing abilities. To explore this issue, we tested field-dependency in a class of body experts, namely yoga practitioners and in non-expert participants. Moreover we explored any link between performance on RFT and self-transcendence (ST), a complex personality construct, which refers to tendency to experience spiritual feelings and ideas. As expected, yoga practitioners (i) were more accurate in assessing the rod's verticality on the RFT, and (ii) expressed significantly higher ST. Interestingly, the performance in these two tests was negatively correlated. More specifically, when asked to provide verticality judgments, highly self-transcendent yoga practitioners were significantly less influenced by a misleading visual context. Our results suggest that being highly self-transcendent may enable yoga practitioners to optimize verticality judgment tasks by relying more on internal (vestibular and proprioceptive) signals coming from their own body, rather than on exteroceptive, visual cues. PMID:25278866
Satgunam, PremNandhini; Datta, Sourav; Chillakala, Koteswararao; Bobbili, Karthik R.; Joshi, Dhruv
2017-01-01
Purpose There are no commercially available devices to measure visual fields in infants. We developed a device, “Pediatric Perimeter,” that quantifies visual field extent (VFE) for infants. We describe the construction, validation, and use of this device. Methods A hemispherical dome with light emitting diodes (LEDs) was constructed. The LEDs were controlled using a computer program to measure reaction time (RT) to gross visual fields (GVF) and the VFE. Participants were tested in supine position in a dark room. Eye or head movement towards the stimuli was monitored with an infrared (IR) camera. Validation was done on 10 adults (mean age: 24.4 ± 5 years) with tunnel vision simulator. Results Perimetry was performed on 19 infants (age: 2.3–12 months), five infants with normal milestones. GVF and VFE were estimated in 17 and 7 infants, respectively. Median RT of infants with developmental delay was 663 ms and 380 ms for healthy infants. Also, 14 children (age: 14 months–6 years) with developmental delay and five patients with cognitive impairment were tested. Conclusion Visual field isopter and RT can be examined with the Pediatric Perimeter device on infants and patients with special needs. Further testing on infants will need to assess the repeatability. A large-scale study will be needed to compare typically developing infants and infants with delayed milestones with this device. Translational Relevance Quantifiable parameters obtained with this device can be used as outcome measures in clinical examination of infants and patients with special needs. This device can be used in pediatric, neurology, and ophthalmology clinics. PMID:28685105
Central corneal thickness and progression of the visual field and optic disc in glaucoma
Chauhan, B C; Hutchison, D M; LeBlanc, R P; Artes, P H; Nicolela, M T
2005-01-01
Aims: To determine whether central corneal thickness (CCT) is a significant predictor of visual field and optic disc progression in open angle glaucoma. Methods: Data were obtained from a prospective study of glaucoma patients tested with static automated perimetry and confocal scanning laser tomography every 6 months. Progression was determined using a trend based approach called evidence of change (EOC) analysis in which sectoral ordinal scores based on the significance of regression coefficients of visual field pattern deviation and neuroretinal rim area over time are summed. Visual field progression was also determined using the event based glaucoma change probability (GCP) analysis using both total and pattern deviation. Results: The sample contained 101 eyes of 54 patients (mean (SD) age 56.5 (9.8) years) with a mean follow up of 9.2 (0.7) years and 20.7 (2.3) sets of examinations every 6 months. Lower CCT was associated with worse baseline visual fields and lower mean IOP in the follow up. In the longitudinal analysis CCT was not correlated with the EOC scores for visual field or optic disc change. In the GCP analyses, there was a tendency for groups classified as progressing to have lower CCT compared to non-progressing groups. In a multivariate analyses accounting for IOP, the opposite was found, whereby higher CCT was associated with visual field progression. None of the independent factors were predictive of optic disc progression. Conclusions: In this cohort of patients with established glaucoma, CCT was not a useful index in the risk assessment of visual field and optic disc progression. PMID:16024855
Cavanaugh, Matthew R; Barbot, Antoine; Carrasco, Marisa; Huxlin, Krystel R
2017-12-10
Training chronic, cortically-blind (CB) patients on a coarse [left-right] direction discrimination and integration (CDDI) task recovers performance on this task at trained, blind field locations. However, fine direction difference (FDD) thresholds remain elevated at these locations, limiting the usefulness of recovered vision in daily life. Here, we asked if this FDD impairment can be overcome by training CB subjects with endogenous, feature-based attention (FBA) cues. Ten CB subjects were recruited and trained on CDDI and FDD with an FBA cue or FDD with a neutral cue. After completion of each training protocol, FDD thresholds were re-measured with both neutral and FBA cues at trained, blind-field locations and at corresponding, intact-field locations. In intact portions of the visual field, FDD thresholds were lower when tested with FBA than neutral cues. Training subjects in the blind field on the CDDI task improved FDD performance to the point that a threshold could be measured, but these locations remained impaired relative to the intact field. FDD training with neutral cues resulted in better blind field FDD thresholds than CDDI training, but thresholds remained impaired relative to intact field levels, regardless of testing cue condition. Importantly, training FDD in the blind field with FBA lowered FDD thresholds relative to CDDI training, and allowed the blind field to reach thresholds similar to the intact field, even when FBA trained subjects were tested with a neutral rather than FBA cue. Finally, FDD training appeared to also recover normal integration thresholds at trained, blind-field locations, providing an interesting double dissociation with respect to CDDI training. In summary, mechanisms governing FBA appear to function normally in both intact and impaired regions of the visual field following V1 damage. Our results mark the first time that FDD thresholds in CB fields have been seen to reach intact field levels of performance. Moreover, FBA can be leveraged during visual training to recover normal, fine direction discrimination and integration performance at trained, blind-field locations, potentiating visual recovery of more complex and precise aspects of motion perception in cortically-blinded fields. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rizzo, Joseph F., III; Ayton, Lauren N.
2014-04-01
Recent advances in the field of visual prostheses, as showcased in this special feature of Journal of Neural Engineering , have led to promising results from clinical trials of a number of devices. However, as noted by these groups there are many challenges involved in assessing vision of people with profound vision loss. As such, it is important that there is consistency in the methodology and reporting standards for clinical trials of visual prostheses and, indeed, the broader vision restoration research field. Two visual prosthesis research groups, the Boston Retinal Implant Project (BRIP) and Bionic Vision Australia (BVA), have agreed to work cooperatively to establish a multi-national Joint Task Force. The aim of this Task Force will be to develop a consensus statement to guide the methods used to conduct and report psychophysical and clinical results of humans who receive visual prosthetic devices. The overarching goal is to ensure maximum benefit to the implant recipients, not only in the outcomes of the visual prosthesis itself, but also in enabling them to obtain accurate information about this research with ease. The aspiration to develop a Joint Task Force was first promulgated at the inaugural 'The Eye and the Chip' meeting in September 2000. This meeting was established to promote the development of the visual prosthetic field by applying the principles of inclusiveness, openness, and collegiality among the growing body of researchers in this field. These same principles underlie the intent of this Joint Task Force to enhance the quality of psychophysical research within our community. Despite prior efforts, a critical mass of interested parties could not congeal. Renewed interest for developing joint guidelines has developed recently because of a growing awareness of the challenges of obtaining reliable measurements of visual function in patients who are severely visually impaired (in whom testing is inherently noisy), and of the importance of comparing outcomes amongst the many research teams that have entered this field, all of which are using different devices implanted at various locations within the visual system and different methods of assessing efficacy. Researchers at the BRIP and BVA believe that use of common methods for testing and for reporting results would benefit all scientists and clinicians in the field, the agencies that regulate human testing, corporations that are invested in the success of this field, and, most importantly, potential patients. The Task Force will be formed with the intent of developing substantive recommendations to provide a measure of consistency and quality control within the field. The guidelines will offer recommendations for the assessment of the: (1) baseline (pre-implant) visual status of potential patients (including specification of the disease diagnosis and impact on visual functioning) and (2) post-operative visual function. The guidelines will be available to the public, research groups and companies. Any groups that choose to adopt the recommendations would be encouraged to include a formal statement of compliance in their presentations and publications. The Task Force will develop these guidelines with the understanding that the ability to perform experiments in the suggested manner might be limited by the particular engineering design and functionality of different prosthesis devices. It is not the intent of the Task Force to write strict test protocols for all parties to follow, but instead to work cooperatively as a research field to develop guidelines about the types of tests that should be implemented, and how they could be reported in a similar format between groups. The opportunity to participate on the Task Force is open to all researchers, clinicians and other specialists who work in the fields of sensory prostheses (both visual and cochlear implants), molecular therapy, stem cells, optogenetics or other fields that share a similar goal of restoring vision to the blind. Decisions about the guidelines will be made democratically, with precautions to prevent any one group or company from having a more dominant voice than any other. One or more smaller working groups may be established to delve more deeply into specific issues, like the ethics of testing or governance structure, and to develop specific wording for recommendations that would be voted on by the entire Task Force group. Ultimately, the various recommendations, once approved democratically, will serve as the consensus document for the Multi-National Joint Task Force. The full list of members of the Task Force and the rules of governance will be published to promote transparency. The Joint Task force will post its guidelines with all signatories on a dedicated page within the website of the Henry Ford Department of Ophthalmology (Detroit). This site was chosen in recognition of the consistent support that Phillip Hessburg MD and the Board of Directors of the Detroit Institute of Ophthalmology, which has recently merged with the Henry Ford Department of Ophthalmology, have so generously and selflessly provided to our field over the past 14 years. This website will also contain a list of all human psychophysical testing that has been performed in the visual prosthetic field, with designations for those studies that were performed in accordance with the guidelines of the Multi-National Task Force, which will assume responsibility for the accuracy of the material. For those who wish to join this Task Force or have further questions, Dr Rizzo and Dr Ayton can be contacted at the email addresses listed above. The founding members of the Task Force anticipate that this digital resource will prove valuable to anyone who has interest in learning more about the achievements in our field, especially our prospective patients, to whom we dedicate our work.
Klein, M; Birch, D G
2009-12-01
To determine whether the Diagnosys full-field stimulus threshold (D-FST) is a valid, sensitive and repeatable psychophysical method of measuring and following visual function in low-vision subjects. Fifty-three affected eyes of 42 subjects with severe retinal degenerative diseases (RDDs) were tested with achromatic stimuli on the D-FST. Included were subjects who were either unable to perform a static perimetric field or had non-detectable or sub-microvolt electroretinograms (ERGs). A subset of 21 eyes of 17 subjects was tested on both the D-FST and the FST2, a previous established full-field threshold test. Seven eyes of 7 normal control subjects were tested on both the D-FST and the FST2. Results for the two methods were compared with the Bland-Altman test. On the D-FST, a threshold could successfully be determined for 13 of 14 eyes with light perception (LP) only (median 0.9 +/- 1.4 log cd/m2), and all eyes determined to be counting fingers (CF; median 0.3 +/- 1.8 log cd/m2). The median full-field threshold for the normal controls was -4.3 +/- 0.6 log cd/m2 on the D-FST and -4.8 +/- 0.9 log cd/m2 on the FST2. The D-FST offers a commercially available method with a robust psychophysical algorithm and is a useful tool for following visual function in low vision subjects.
Ocular findings in MELAS syndrome – a case report.
Modrzejewska, Monika; Chrzanowska, Martyna; Modrzejewska, Anna; Romanowska, Hanna; Ostrowska, Iwona; Giżewska, Maria
We present a case of a child with MELAS syndrome (mitochondrial encephalo-myopathy with lactic acidosis and stroke-like episodes), discussing clinical manifestation, ocular findings and diagnostic challenges. Predominant ocular symptom was a transient complete visual loss, while the predominant ocular sign was a visual field defect. The diagnosia was based on clinical manifestation, laboratory tests, brain scans and genetic testing which confirmed the pathognomonic mutation in the MTTL1 gene encoding the mitochondrial tRNA for leucine 3243> G. Ocular examination demonstrated decreased visual acuity (with bilateral best corrected visual acuity of .1). Periodical, transient visual loss and visual field defects were clinically predominant. Specialist investigations were carried out, which demonstrated homonymous hemianopia (kinetic perimetry), bilateral partial optic nerve atrophy (RetCam). Funduscopy and electrophysiology mfERG study did not confirm features of retinitis pigmentosa. The brain scans revealed numerous small cortical ischemic lesions within the frontal, parietal and temporal lobes, post-stroke focal areas within the occipital lobes and diffuse calcifications of the basal ganglia. During several years of follow-up, visual field defects showed progressive concentric narrowing. The patient received a long-term treatment with arginine, coenzyme Q and vitamin D, both oral and intravenous, but no beneficial effect for the improvement of ophthalmic condition was observed. As it is the case in severe MELAS syndrome, the course of disease was fatal and the patientdied at the age of 14.
An aftereffect of adaptation to mean size
Corbett, Jennifer E.; Wurnitsch, Nicole; Schwartz, Alex; Whitney, David
2013-01-01
The visual system rapidly represents the mean size of sets of objects. Here, we investigated whether mean size is explicitly encoded by the visual system, along a single dimension like texture, numerosity, and other visual dimensions susceptible to adaptation. Observers adapted to two sets of dots with different mean sizes, presented simultaneously in opposite visual fields. After adaptation, two test patches replaced the adapting dot sets, and participants judged which test appeared to have the larger average dot diameter. They generally perceived the test that replaced the smaller mean size adapting set as being larger than the test that replaced the larger adapting set. This differential aftereffect held for single test dots (Experiment 2) and high-pass filtered displays (Experiment 3), and changed systematically as a function of the variance of the adapting dot sets (Experiment 4), providing additional support that mean size is adaptable, and therefore explicitly encoded dimension of visual scenes. PMID:24348083
Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F
2014-08-01
To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
An Experimental Evaluation of a Field Sobriety Test Battery in the Marine Environment
DOT National Transportation Integrated Search
1990-06-01
This Report describes an investigation of the accuracy of a FST (Field Sobriety Test) : battery used in the marine environment. FSTs rely on the observation and measurement of : the effect of alcohol intoxication on coordination, visual tracking and ...
Liu, Shu; Yu, Marco; Weinreb, Robert N; Lai, Gilda; Lam, Dennis Shun-Chiu; Leung, Christopher Kai-Shun
2014-05-02
We compared the detection of visual field progression and its rate of change between standard automated perimetry (SAP) and Matrix frequency doubling technology perimetry (FDTP) in glaucoma. We followed prospectively 217 eyes (179 glaucoma and 38 normal eyes) for SAP and FDTP testing at 4-month intervals for ≥36 months. Pointwise linear regression analysis was performed. A test location was considered progressing when the rate of change of visual sensitivity was ≤-1 dB/y for nonedge and ≤-2 dB/y for edge locations. Three criteria were used to define progression in an eye: ≥3 adjacent nonedge test locations (conservative), any three locations (moderate), and any two locations (liberal) progressed. The rate of change of visual sensitivity was calculated with linear mixed models. Of the 217 eyes, 6.1% and 3.9% progressed with the conservative criteria, 14.5% and 5.6% of eyes progressed with the moderate criteria, and 20.1% and 11.7% of eyes progressed with the liberal criteria by FDTP and SAP, respectively. Taking all test locations into consideration (total, 54 × 179 locations), FDTP detected more progressing locations (176) than SAP (103, P < 0.001). The rate of change of visual field mean deviation (MD) was significantly faster for FDTP (all with P < 0.001). No eyes showed progression in the normal group using the conservative and the moderate criteria. With a faster rate of change of visual sensitivity, FDTP detected more progressing eyes than SAP at a comparable level of specificity. Frequency doubling technology perimetry can provide a useful alternative to monitor glaucoma progression.
High Performance Visualization using Query-Driven Visualizationand Analytics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bethel, E. Wes; Campbell, Scott; Dart, Eli
2006-06-15
Query-driven visualization and analytics is a unique approach for high-performance visualization that offers new capabilities for knowledge discovery and hypothesis testing. The new capabilities akin to finding needles in haystacks are the result of combining technologies from the fields of scientific visualization and scientific data management. This approach is crucial for rapid data analysis and visualization in the petascale regime. This article describes how query-driven visualization is applied to a hero-sized network traffic analysis problem.
Visual impairment, visual functioning, and quality of life assessments in patients with glaucoma.
Parrish, R K
1996-01-01
BACKGROUND/PURPOSE: To determine the relation between visual impairment, visual functioning, and the global quality of life in patients with glaucoma. METHODS: Visual impairment, defined with the American Medical Association Guides to the Evaluation of Permanent Impairment; visual functioning, measured with the VF-14 and the Field Test Version of the National Eye Institute-Visual Functioning Questionnaire (NEI-VFQ); and the global quality of life, assessed with the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), were determined in 147 consecutive patients with glaucoma. RESULTS: None of the SF-36 domains demonstrated more than a weak correlation with visual impairment. The VF-14 scores were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual field impairment; vision specific social functioning, near activities, vision specific role difficulties, general vision, vision specific mental health, color vision, and driving were modestly correlated; visual pain was weakly correlated; and two were not significantly correlated. Correcting for visual actuity weakened the strength of the correlation coefficients. CONCLUSIONS: The SF-36 is unlikely to be useful in determining visual impairment in patients with glaucoma. Based on the moderate correlation between visual field impairment and the VF-14 score, this questionnaire may be generalizable to patients with glaucoma. Several of the NEI-VFQ scales correlate with visual field impairment scores in patients with a wide range of glaucomatous damage. PMID:8981717
VARIABILITY OF VISUAL FIELD MEASUREMENTS IS CORRELATED WITH THE GRADIENT OF VISUAL SENSITIVITY
Wyatt, Harry J.; Dul, Mitchell W.; Swanson, William H.
2007-01-01
Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, the rate at which sensitivity changes with location. We tested one eye each, twice within 3 weeks, of 29 patients with glaucoma, 17 young normal subjects and 13 older normal subjects. The 10-2 test pattern with the SITA Standard algorithm was used to assess sensitivity at locations with 2° spacing. Variability and gradient were calculated at individual test locations. Matrix correlations were determined between variability and gradient, and were substantial for the patients with glaucoma. The results were consistent with a substantial contribution to test-retest variability from small fixational eye movements interacting with visual field gradient. Successful characterization of the gradient of sensitivity appears to require sampling at relatively close spacing, as in the 10-2 test pattern. PMID:17320924
Variability of visual field measurements is correlated with the gradient of visual sensitivity.
Wyatt, Harry J; Dul, Mitchell W; Swanson, William H
2007-03-01
Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, the rate at which sensitivity changes with location. We tested one eye each, twice within 3 weeks, of 29 patients with glaucoma, 17 young normal subjects and 13 older normal subjects. The 10-2 test pattern with the SITA Standard algorithm was used to assess sensitivity at locations with 2 degrees spacing. Variability and gradient were calculated at individual test locations. Matrix correlations were determined between variability and gradient, and were substantial for the patients with glaucoma. The results were consistent with a substantial contribution to test-retest variability from small fixational eye movements interacting with visual field gradient. Successful characterization of the gradient of sensitivity appears to require sampling at relatively close spacing, as in the 10-2 test pattern.
NASA Technical Reports Server (NTRS)
Hopkins, William D.; Washburn, David A.; Rumbaugh, Duane M.
1990-01-01
Visual forms were unilaterally presented using a video-task paradigm to ten humans, chimpanzees, and two rhesus monkeys to determine whether hemispheric advantages existed in the processing of these stimuli. Both accuracy and reaction time served as dependent measures. For the chimpanzees, a significant right hemisphere advantage was found within the first three test sessions. The humans and monkeys failed to show a hemispheric advantage as determined by accuracy scores. Analysis of reaction time data revealed a significant left hemisphere advantage for the monkeys. A visual half-field x block interaction was found for the chimpanzees, with a significant left visual field advantage in block two, whereas a right visual field advantage was found in block four. In the human subjects, a left visual field advantage was found in block three when they used their right hands to respond. The results are discussed in relation to recent reports of hemispheric advantages for nonhuman primates.
Huisingh, Carrie; McGwin, Gerald; Owsley, Cynthia
2017-01-01
Background Many studies on vision and driving cessation have relied on measures of sensory function, which are insensitive to the higher order cognitive aspects of visual processing. The purpose of this study was to examine the association between traditional measures of visual sensory function and higher order visual processing skills with incident driving cessation in a population-based sample of older drivers. Methods Two thousand licensed drivers aged ≥70 were enrolled and followed-up for three years. Tests for central vision and visual processing were administered at baseline and included visual acuity, contrast sensitivity, sensitivity in the driving visual field, visual processing speed (Useful Field of View (UFOV) Subtest 2 and Trails B), and spatial ability measured by the Visual Closure Subtest of the Motor-free Visual Perception Test. Participants self-reported the month and year of driving cessation and provided a reason for cessation. Cox proportional hazards models were used to generate crude and adjusted hazard ratios with 95% confidence intervals between visual functioning characteristics and risk of driving cessation over a three-year period. Results During the study period, 164 participants stopped driving which corresponds to a cumulative incidence of 8.5%. Impaired contrast sensitivity, visual fields, visual processing speed (UFOVand Trails B), and spatial ability were significant risk factors for subsequent driving cessation after adjusting for age, gender, marital status, number of medical conditions, and miles driven. Visual acuity impairment was not associated with driving cessation. Medical problems (63%), specifically musculoskeletal and neurological problems, as well as vision problems (17%) were cited most frequently as the reason for driving cessation. Conclusion Assessment of cognitive and visual functioning can provide useful information about subsequent risk of driving cessation among older drivers. In addition, a variety of factors, not just vision, influenced the decision to stop driving and may be amenable to intervention. PMID:27353969
Inhibition of Return in the Visual Field
Bao, Yan; Lei, Quan; Fang, Yuan; Tong, Yu; Schill, Kerstin; Pöppel, Ernst; Strasburger, Hans
2013-01-01
Inhibition of return (IOR) as an indicator of attentional control is characterized by an eccentricity effect, that is, the more peripheral visual field shows a stronger IOR magnitude relative to the perifoveal visual field. However, it could be argued that this eccentricity effect may not be an attention effect, but due to cortical magnification. To test this possibility, we examined this eccentricity effect in two conditions: the same-size condition in which identical stimuli were used at different eccentricities, and the size-scaling condition in which stimuli were scaled according to the cortical magnification factor (M-scaling), thus stimuli being larger at the more peripheral locations. The results showed that the magnitude of IOR was significantly stronger in the peripheral relative to the perifoveal visual field, and this eccentricity effect was independent of the manipulation of stimulus size (same-size or size-scaling). These results suggest a robust eccentricity effect of IOR which cannot be eliminated by M-scaling. Underlying neural mechanisms of the eccentricity effect of IOR are discussed with respect to both cortical and subcortical structures mediating attentional control in the perifoveal and peripheral visual field. PMID:23820946
Fallahi Motlagh, Behzad; Sadeghi, Ali
2017-01-01
The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values <0.001 for all correlations. The mean MD scores (using both SWAP and SAP) were significantly higher in the eyes with thin than in those with intermediate average macular thickness. Intraeye (superior macula thickness - inferior macula thickness) asymmetries correlated significantly with both PSD-SWAP (r = 0.63, P < 0.001) and PSD-SAP (r = 0.26, P = 0.01) scores. This study revealed a significant correlation between macular thickness and visual field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.
Udagawa, Sachiko; Iwase, Aiko; Susuki, Yuto; Kunimatsu-Sanuki, Shiho; Fukuchi, Takeo; Matsumoto, Chota; Ohno, Yuko; Ono, Hiroshi; Sugiyama, Kazuhisa; Araie, Makoto
2018-01-01
Purpose Traffic accidents are associated with the visual function of drivers, as well as many other factors. Driving simulator systems have the advantage of controlling for traffic- and automobile-related conditions, and using pinhole glasses can control the degree of concentric concentration of the visual field. We evaluated the effect of concentric constriction of the visual field on automobile driving, using driving simulator tests. Methods Subjects meeting criteria for normal eyesight were included in the study. Pinhole glasses with variable aperture sizes were adjusted to mimic the conditions of concentric visual field constrictions of 10° and 15°, using a CLOCK CHART®. The test contained 8 scenarios (2 oncoming right-turning cars and 6 jump-out events from the side). Results Eighty-eight subjects were included in the study; 37 (mean age = 52.9±15.8 years) subjects were assigned to the 15° group, and 51 (mean = 48.6±15.5 years) were assigned to the 10° group. For all 8 scenarios, the number of accidents was significantly higher among pinhole wearing subjects. The average number of all types of accidents per person was significantly higher in the pinhole 10° group (4.59±1.81) than the pinhole 15° group (3.68±1.49) (P = 0.032). The number of accidents associated with jump-out scenarios, in which a vehicle approaches from the side on a straight road with a good view, was significantly higher in the pinhole 10° group than in the pinhole 15° group. Conclusions Concentric constriction of the visual field was associated with increased number of traffic accidents. The simulation findings indicated that a visual field of 10° to 15° may be important for avoiding collisions in places where there is a straight road with a good view. PMID:29538425
Car driving in schizophrenia: can visual memory and organization make a difference?
Lipskaya-Velikovsky, Lena; Kotler, Moshe; Weiss, Penina; Kaspi, Maya; Gamzo, Shimrit; Ratzon, Navah
2013-09-01
Driving is a meaningful occupation which is ascribed to functional independence in schizophrenia. Although it is estimated that individuals with schizophrenia have two times more traffic accidents, little research has been done in this field. Present research explores differences in mental status, visual working memory and visual organization between drivers and non-drivers with schizophrenia in comparison to healthy drivers. There were three groups in the study: 20 drivers with schizophrenia, 20 non-driving individuals with schizophrenia and 20 drivers without schizophrenia (DWS). Visual perception was measured with Rey-Osterrieth Complex Figure test and a general cognitive status with Mini-Mental State Examination. The general cognitive status predicted actual driving situation in people with schizophrenia. No statistically significant differences were found between driving and non-driving persons with schizophrenia on any of the visual parameters tested, although these abilities were significantly lower than those of DWS. The research demonstrates that impairment of visual abilities does not prevent people with schizophrenia from driving and emphasizes the importance of general cognitive status for complex and multidimensional everyday tasks. The findings support the need for further investigation in the field of car driving for this population - a move that will considerably contribute to the participation and well-being. Implication for Rehabilitation Unique approach for driving evaluation in schizophrenia should be designed since direct applications of knowledge and practice acquired from other populations are not reliable. This research demonstrates that visual perception deficits in schizophrenia do not prevent clients from driving, and general cognitive status appeared to be a valid determinant for actual driving. We recommended usage of a general test of cognition such as Mini-Mental State Examination, or conjunction number of cognitive factors such as executive functions (e.g., Trail Making Test) and attention (e.g., Continuous Performance Test) in addition to spatial-visual ability tests (e.g., Rey-Osterrieth Complex Figure test) for considering driving status in schizophrenia.
Hemifield memory for attractiveness.
Deblieck, C; Zaidel, D W
2003-07-01
In order to determine whether or not facial attractiveness plays a role in hemispheric facial memory, 35 right-handed participants first assigned attractiveness ratings to faces and then performed a recognition test on those faces in the left visual half-field (LVF) and right visual half-field (RVF). We found significant interactions between the experimental factors and visual half-field. There were significant differences in the extreme ends of the rating scale, that is, the very unattractive versus the very attractive faces: Female participants remembered very attractive faces of both women and men, with memory being superior in the RVF than in the LVF. In contrast, the male participants remembered very unattractive faces of both women and men; RVF memory was better than the LVF for women faces while for men faces memory was superior in the LVF. The interactions with visual half-field suggest that hemispheric biases in remembering faces are influenced by degree of attractiveness.
Probing glaucoma visual damage by rarebit perimetry.
Brusini, P; Salvetat, M L; Parisi, L; Zeppieri, M
2005-02-01
To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluated using Student-Newman-Keuls and chi(2) tests. Correlation between HFA and RBP parameters was assessed using the Pearson's correlation coefficients and regression analysis. Sensitivity and specificity of RBP in detecting early glaucomatous visual damage were calculated with different algorithms. RBP-mean hit rate (MHR) was respectively 88.6% (SD 4.8%) in controls; 79.1% (10.9%) in the OH group; 64.3% (13.8%) in the POAG group (differences statistically significant). Good correlation in the POAG group was found between HFA-mean deviation and RBP-MHR. Largest AROC (0.95) and optimal sensitivity (97.4%) were obtained when an abnormal RBP test was defined as having (at least 1): MHR <80%; >15 areas with a non-hit rate of >10%; > or =2 areas with a non-hit rate of >50%; at least one area with a non-hit rate of > or =70%. The RBP appeared to be a rapid, comfortable, and easily available perimetric test (requiring only a PC device), showing a high sensitivity and specificity in detecting early glaucomatous visual field defects.
2012-01-01
Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence. PMID:22452821
Visual Confirmation of Voice Takeoff Clearance (VICON) Alternative Study
DOT National Transportation Integrated Search
1980-05-01
This report presents the results of a program undertaken to study potential alternatives to the VICON (Visual Confirmation of Voice Takeoff Clearance) System which has undergone operational field tests at Bradley International Airport, Windsor Locks,...
Wilkins, Luke; Mann, David; Dain, Stephen; Hayward, Thomas; Allen, Peter
2018-05-28
The International Cricket Council recently introduced new regulations for helmets in cricket. Amongst other changes, these regulations limit batters from adjusting the gap between the peak and the grille, resulting in some controversy over whether the new helmet design reduces visibility of the ball. This study compared the visual field of individuals when wearing an old helmet that does not conform to the new regulations, and the equivalent replacement which does. The visual field of 10 male participants was tested whilst wearing an old and new helmet. The new helmet resulted in a significant reduction in the visual field of the wearer (M = 66.1 out of 76 points seen in the new helmet vs. 74.8 seen with the old helmet), with the restriction predominantly confined to the superior visual field. The new regulations do appear to restrict the visual field of batters, confirming the anecdotal reports of players. However, the majority of this restriction occurs in the superior field, suggesting that the impact on batting performance may be limited. The importance of considering the impact that new helmet regulations can have on vision, batting performance, and player safety is discussed.
Hemispheric asymmetry of liking for representational and abstract paintings.
Nadal, Marcos; Schiavi, Susanna; Cattaneo, Zaira
2017-10-13
Although the neural correlates of the appreciation of aesthetic qualities have been the target of much research in the past decade, few experiments have explored the hemispheric asymmetries in underlying processes. In this study, we used a divided visual field paradigm to test for hemispheric asymmetries in men and women's preference for abstract and representational artworks. Both male and female participants liked representational paintings more when presented in the right visual field, whereas preference for abstract paintings was unaffected by presentation hemifield. We hypothesize that this result reflects a facilitation of the sort of visual processes relevant to laypeople's liking for art-specifically, local processing of highly informative object features-when artworks are presented in the right visual field, given the left hemisphere's advantage in processing such features.
Harness, B Z; Bental, E; Carmon, A
1976-03-01
Cognition and performance of patients with localized and diffuse brain damage was evaluated through the application of objective perceptual testing. A series of visual perceptual and verbal tests, memory tests, as well as reaction time tasks were administered to the patients by logic programming equipment. In order to avoid a bias due to communicative disorders, all responses were motor, and achievement was scored in terms of correct identification and latencies of response. Previously established norms based on a large sample of non-brain-damaged hospitalized patients served to standardize the performance of the brain-damaged patient since preliminary results showed that age and educational level constitute an important variable affecting performance of the control group. The achievement of brain-damaged patients, corrected for these factors, was impaired significantly in all tests with respect to both recognition and speed of performance. Lateralized effects of brain damage were not significantly demonstrated. However, when the performance was analyzed with respect to the locus of visual input, it was found that patients with right hemispheric lesions showed impairment mainly on perception of figurative material, and that this deficit was more apparent in the left visual field. Conversely, patients with left hemispheric lesions tended to show impairment on perception of visually presented verbal material when the input was delivered to the right visual field.
Signal/noise analysis to compare tests for measuring visual field loss and its progression.
Artes, Paul H; Chauhan, Balwantray C
2009-10-01
To describe a methodology for establishing signal-to-noise ratios (SNRs) for different perimetric techniques, and to compare SNRs of frequency-doubling technology (FDT2) perimetry and standard automated perimetry (SAP). Fifteen patients with open-angle glaucoma (median MD, -2.6 dB, range +0.2 to -16.1 dB) were tested six times with FDT2 and SAP (SITA Standard program 24-2) within a 4-week period. Signals were estimated from the average superior-inferior difference between the mean deviation (MD) values in five mirror-pair sectors of the Glaucoma Hemifield Test, and noise from the dispersion of these differences over the six repeated tests. SNRs of FDT2 and SAP were compared by mixed-effects modeling. There was moderate correlation between the signals of FDT2 and SAP (r(2) = 0.68, P < 0.001), but no correlation of noise (r(2) = 0.01, P = 0.16). Although both signal as well as noise estimates were higher with FDT2 compared with SAP, 60% to 70% of sector pairs showed higher SNRs with FDT2. The SNRs of FDT2 were between 20% and 40% higher than those of SAP (P = 0.01). There were no meaningful differences between parametric and nonparametric estimates of signal, noise, or SNR. The higher SNRs of FDT2 suggest that this technique is at least as efficient as SAP at detecting localized visual field losses. Signal/noise analyses may provide a useful approach for comparing visual field tests independent of their decibel scales and may provide an initial indication of sensitivity to visual field change over time.
Wall, Michael; Woodward, Kimberly R; Doyle, Carrie K; Artes, Paul H
2009-02-01
Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP V), with the full-threshold strategy; Matrix (FDT II), and Motion perimetry. One eye each of 120 patients with glaucoma was examined on the same day with these four perimetric tests and retested 1 to 8 weeks later. The decibel scales were adjusted to make the test's scales numerically similar. Retest variability was examined by establishing the distributions of retest threshold estimates, for each threshold level observed at the first test. The 5th and 95th percentiles of the retest distribution were used as point-wise limits of retest variability. Regression analyses were performed to quantify the relationship between visual field sensitivity and variability. With SAP III, the retest variability increased substantially with reducing sensitivity. Corresponding increases with SAP V, Matrix, and Motion perimetry were considerably smaller or absent. With SAP III, sensitivity explained 22% of the retest variability (r(2)), whereas corresponding data for SAP V, Matrix, and Motion perimetry were 12%, 2%, and 2%, respectively. Variability of Matrix and Motion perimetry does not increase as substantially as that of SAP III in damaged areas of the visual field. Increased sampling with the larger stimuli of these techniques is the likely explanation for this finding. These properties may make these stimuli excellent candidates for early detection of visual field progression.
Functional vision loss: a diagnosis of exclusion.
Villegas, Rex B; Ilsen, Pauline F
2007-10-01
Most cases of visual acuity or visual field loss can be attributed to ocular pathology or ocular manifestations of systemic pathology. They can also occasionally be attributed to nonpathologic processes or malingering. Functional vision loss is any decrease in vision the origin of which cannot be attributed to a pathologic or structural abnormality. Two cases of functional vision loss are described. In the first, a 58-year-old man presented for a baseline eye examination for enrollment in a vision rehabilitation program. He reported bilateral blindness since a motor vehicle accident with head trauma 4 years prior. Entering visual acuity was "no light perception" in each eye. Ocular health examination was normal and the patient made frequent eye contact with the examiners. He was referred for neuroimaging and electrophysiologic testing. The second case was a 49-year-old man who presented with a long history of intermittent monocular diplopia. His medical history was significant for psycho-medical evaluations and a diagnosis of factitious disorder. Entering uncorrected visual acuities were 20/20 in each eye, but visual field testing found constriction. No abnormalities were found that could account for the monocular diplopia or visual field deficit. A diagnosis of functional vision loss secondary to factitious disorder was made. Functional vision loss is a diagnosis of exclusion. In the event of reduced vision in the context of a normal ocular health examination, all other pathology must be ruled out before making the diagnosis of functional vision loss. Evaluation must include auxiliary ophthalmologic testing, neuroimaging of the visual pathway, review of the medical history and lifestyle, and psychiatric evaluation. Comanagement with a psychiatrist is essential for patients with functional vision loss.
Resilience to the contralateral visual field bias as a window into object representations
Garcea, Frank E.; Kristensen, Stephanie; Almeida, Jorge; Mahon, Bradford Z.
2016-01-01
Viewing images of manipulable objects elicits differential blood oxygen level-dependent (BOLD) contrast across parietal and dorsal occipital areas of the human brain that support object-directed reaching, grasping, and complex object manipulation. However, it is unknown which object-selective regions of parietal cortex receive their principal inputs from the ventral object-processing pathway and which receive their inputs from the dorsal object-processing pathway. Parietal areas that receive their inputs from the ventral visual pathway, rather than from the dorsal stream, will have inputs that are already filtered through object categorization and identification processes. This predicts that parietal regions that receive inputs from the ventral visual pathway should exhibit object-selective responses that are resilient to contralateral visual field biases. To test this hypothesis, adult participants viewed images of tools and animals that were presented to the left or right visual fields during functional magnetic resonance imaging (fMRI). We found that the left inferior parietal lobule showed robust tool preferences independently of the visual field in which tool stimuli were presented. In contrast, a region in posterior parietal/dorsal occipital cortex in the right hemisphere exhibited an interaction between visual field and category: tool-preferences were strongest contralateral to the stimulus. These findings suggest that action knowledge accessed in the left inferior parietal lobule operates over inputs that are abstracted from the visual input and contingent on analysis by the ventral visual pathway, consistent with its putative role in supporting object manipulation knowledge. PMID:27160998
Schwarz, Sebastian; Albert, Laurence; Wystrach, Antoine; Cheng, Ken
2011-03-15
Many animal species, including some social hymenoptera, use the visual system for navigation. Although the insect compound eyes have been well studied, less is known about the second visual system in some insects, the ocelli. Here we demonstrate navigational functions of the ocelli in the visually guided Australian desert ant Melophorus bagoti. These ants are known to rely on both visual landmark learning and path integration. We conducted experiments to reveal the role of ocelli in the perception and use of celestial compass information and landmark guidance. Ants with directional information from their path integration system were tested with covered compound eyes and open ocelli on an unfamiliar test field where only celestial compass cues were available for homing. These full-vector ants, using only their ocelli for visual information, oriented significantly towards the fictive nest on the test field, indicating the use of celestial compass information that is presumably based on polarised skylight, the sun's position or the colour gradient of the sky. Ants without any directional information from their path-integration system (zero-vector) were tested, also with covered compound eyes and open ocelli, on a familiar training field where they have to use the surrounding panorama to home. These ants failed to orient significantly in the homeward direction. Together, our results demonstrated that M. bagoti could perceive and process celestial compass information for directional orientation with their ocelli. In contrast, the ocelli do not seem to contribute to terrestrial landmark-based navigation in M. bagoti.
Swivel arm perimeter for visual field testing in different body positions.
Flammer, J; Hendrickson, P; Lietz, A; Stümpfig, D
1993-01-01
To investigate the influence of body position on visual field results, a 'swivel arm perimeter' was built, based on a modified Octopus 1-2-3. Here, the measuring unit was detected from the control unit and mounted on a swivel arm, allowing its movement in all directions. The first results obtained with this device have indicated that its development was worthwhile.
Nishino, Kazuaki; Yoshida, Fujiko; Nitta, Akari; Saito, Mieko; Saito, Kazuuchi
2013-12-01
To evaluate retrospectively seasonal fluctuations of transient intraocular pressure (IOP) elevation after automated visual field examination in patients with primary open-angle glaucoma (POAG). We reviewed 53 consecutive patients with POAG who visited Kaimeido Ophthalmic and Dental Clinic from January 2011 to March 2013, 21 men and 32 women aged 67.7 +/- 11.2 years. The patients were divided into 4 groups, spring, summer, autumn, and winter according to the month of automated visual field examination and both eyes of each patient were enrolled. IOP was measured immediately after automated visual field examination (vf IOP) and compared with the average IOP from the previous 3 months (pre IOP) and with the average IOP from the following 3 months (post IOP) in each season. IOP elevation rate was defined as (vf IOP- pre IOP)/pre IOP x 100% and calculated for each season (paired t test). Additionally, the correlation between mean deviation (MD) and IOP elevation rate was evaluated (single regression analysis). Exclusion criteria were patients who received cataract surgery during this study or had a history of any previous glaucoma surgery. The automated visual field test was performed with a Humphrey field analyzer and the Central 30-2 FASTPAC threshold program. The average vf IOP was 14.5 +/- 2.5 mmHg, higher than pre IOP 13.8 +/- 2.4 mmHg (p < 0.0001) and the post IOP 13.8 +/- 2.2 mmHg (p < 0.0001). IOP elevation rate in each season was 4.1 11.6% in spring (n = 22, p = 0.18), 0.1 +/- 9.9% in summer (n = 16, p = 1.0), 5.0 +/- 13.8% in autumn (n = 30. p = 0.11), 10.6 +/- 8.8% in winter (n = 38, p < 0.0001). The MD was not correlated with IOP elevation rate (p = 0.17). Patients with POAG show a transient IOP elevation after automated visual field examination, especially in the winter but not in the summer.
NASA Astrophysics Data System (ADS)
Poertner, T.
1993-11-01
Glow discharge flow visualization experiments are demonstrated which have been performed to enable a first assessment of the HERMES 1.0 leading edge thruster configuration concerning interference between the thruster plumes of the reaction control system (RCS) and the surrounding flow field. The results of the flow visualization tests are presented in exemplary selected photographs. Additional Pitot pressure measurements support assumptions concerning interference induced pressure changes that may result from the observed significant flow field disturbances.
New developments in supra-threshold perimetry.
Henson, David B; Artes, Paul H
2002-09-01
To describe a series of recent enhancements to supra-threshold perimetry. Computer simulations were used to develop an improved algorithm (HEART) for the setting of the supra-threshold test intensity at the beginning of a field test, and to evaluate the relationship between various pass/fail criteria and the test's performance (sensitivity and specificity) and how they compare with modern threshold perimetry. Data were collected in optometric practices to evaluate HEART and to assess how the patient's response times can be analysed to detect false positive response errors in visual field test results. The HEART algorithm shows improved performance (reduced between-eye differences) over current algorithms. A pass/fail criterion of '3 stimuli seen of 3-5 presentations' at each test location reduces test/retest variability and combines high sensitivity and specificity. A large percentage of false positive responses can be detected by comparing their latencies to the average response time of a patient. Optimised supra-threshold visual field tests can perform as well as modern threshold techniques. Such tests may be easier to perform for novice patients, compared with the more demanding threshold tests.
Hagiwara, Y; Yamamoto, T; Kitazawa, Y
2000-03-01
We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.
Binocular Glaucomatous Visual Field Loss and Its Impact on Visual Exploration - A Supermarket Study
Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena
2014-01-01
Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as “passed” or “failed” with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p<0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p<0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a “time-effective” compensatory mechanism during the present supermarket task. PMID:25162522
Binocular glaucomatous visual field loss and its impact on visual exploration--a supermarket study.
Sippel, Katrin; Kasneci, Enkelejda; Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena
2014-01-01
Advanced glaucomatous visual field loss may critically interfere with quality of life. The purpose of this study was to (i) assess the impact of binocular glaucomatous visual field loss on a supermarket search task as an example of everyday living activities, (ii) to identify factors influencing the performance, and (iii) to investigate the related compensatory mechanisms. Ten patients with binocular glaucoma (GP), and ten healthy-sighted control subjects (GC) were asked to collect twenty different products chosen randomly in two supermarket racks as quickly as possible. The task performance was rated as "passed" or "failed" with regard to the time per correctly collected item. Based on the performance of control subjects, the threshold value for failing the task was defined as μ+3σ (in seconds per correctly collected item). Eye movements were recorded by means of a mobile eye tracker. Eight out of ten patients with glaucoma and all control subjects passed the task. Patients who failed the task needed significantly longer time (111.47 s ±12.12 s) to complete the task than patients who passed (64.45 s ±13.36 s, t-test, p < 0.001). Furthermore, patients who passed the task showed a significantly higher number of glances towards the visual field defect (VFD) area than patients who failed (t-test, p < 0.05). According to these results, glaucoma patients with defects in the binocular visual field display on average longer search times in a naturalistic supermarket task. However, a considerable number of patients, who compensate by frequent glancing towards the VFD, showed successful task performance. Therefore, systematic exploration of the VFD area seems to be a "time-effective" compensatory mechanism during the present supermarket task.
Kalyani, Partho S; Fawzi, Amani A; Gangaputra, Sapna; van Natta, Mark L; Hubbard, Larry D; Danis, Ronald P; Thorne, Jennifer E; Holland, Gary N
2012-03-01
To evaluate relationships between retinal vessel caliber and tests of visual function among people with AIDS. Longitudinal, observational cohort study. We evaluated data for participants without ocular opportunistic infections at initial examination (baseline) in the Longitudinal Studies of the Ocular Complications of AIDS (1998-2008). Visual function was evaluated with best-corrected visual acuity, Goldmann perimetry, automated perimetry (Humphrey Field Analyzer), and contrast sensitivity (CS) testing. Semi-automated grading of fundus photographs (1 eye/participant) determined central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), and arteriole-to-venule ratio (AVR) at baseline. Multiple linear regression models, using forward selection, sought independent relationships between indices and visual function variables. Included were 1250 participants. Smaller AVR was associated with reduced visual field by Goldmann perimetry (P = .003) and worse mean deviation (P = .02) on automated perimetry and possibly with worse pattern standard deviation (PSD) on automated perimetry (P = .06). There was a weak association between smaller AVR and worse CS (P = .07). Relationships were independent of antiretroviral therapy and level of immunodeficiency (CD4+ T lymphocyte count, human immunodeficiency virus [HIV] RNA blood level). On longitudinal analysis, retinal vascular indices at baseline did not predict changes in visual function. Variation in retinal vascular indices is associated with abnormal visual function in people with AIDS, manifested by visual field loss and possibly by reduced CS. Relationships are consistent with the hypothesis that HIV-related retinal vasculopathy is a contributing factor to vision dysfunction among HIV-infected individuals. Longitudinal studies are needed to determine whether changes in indices predict change in visual function. Copyright © 2012 Elsevier Inc. All rights reserved.
Brightness Induction and Suprathreshold Vision: Effects of Age and Visual Field
McCourt, Mark E.; Leone, Lynnette M.; Blakeslee, Barbara
2014-01-01
A variety of visual capacities show significant age-related alterations. We assessed suprathreshold contrast and brightness perception across the lifespan in a large sample of healthy participants (N = 155; 142) ranging in age from 16–80 years. Experiment 1 used a quadrature-phase motion cancelation technique (Blakeslee & McCourt, 2008) to measure canceling contrast (in central vision) for induced gratings at two temporal frequencies (1 Hz and 4 Hz) at two test field heights (0.5° or 2° × 38.7°; 0.052 c/d). There was a significant age-related reduction in canceling contrast at 4 Hz, but not at 1 Hz. We find no age-related change in induction magnitude in the 1 Hz condition. We interpret the age-related decline in grating induction magnitude at 4 Hz to reflect a diminished capacity for inhibitory processing at higher temporal frequencies. In Experiment 2 participants adjusted the contrast of a matching grating (0.5° or 2° × 38.7°; 0.052 c/d) to equal that of both real (30% contrast, 0.052 c/d) and induced (McCourt, 1982) standard gratings (100% inducing grating contrast; 0.052 c/d). Matching gratings appeared in the upper visual field (UVF) and test gratings appeared in the lower visual field (LVF), and vice versa, at eccentricities of ±7.5°. Average induction magnitude was invariant with age for both test field heights. There was a significant age-related reduction in perceived contrast of stimuli in the LVF versus UVF for both real and induced gratings. PMID:25462024
Perceptual learning increases the strength of the earliest signals in visual cortex.
Bao, Min; Yang, Lin; Rios, Cristina; He, Bin; Engel, Stephen A
2010-11-10
Training improves performance on most visual tasks. Such perceptual learning can modify how information is read out from, and represented in, later visual areas, but effects on early visual cortex are controversial. In particular, it remains unknown whether learning can reshape neural response properties in early visual areas independent from feedback arising in later cortical areas. Here, we tested whether learning can modify feedforward signals in early visual cortex as measured by the human electroencephalogram. Fourteen subjects were trained for >24 d to detect a diagonal grating pattern in one quadrant of the visual field. Training improved performance, reducing the contrast needed for reliable detection, and also reliably increased the amplitude of the earliest component of the visual evoked potential, the C1. Control orientations and locations showed smaller effects of training. Because the C1 arises rapidly and has a source in early visual cortex, our results suggest that learning can increase early visual area response through local receptive field changes without feedback from later areas.
Multiparameter vision testing apparatus
NASA Technical Reports Server (NTRS)
Hunt, S. R., Jr.; Homkes, R. J.; Poteate, W. B.; Sturgis, A. C. (Inventor)
1975-01-01
Compact vision testing apparatus is described for testing a large number of physiological characteristics of the eyes and visual system of a human subject. The head of the subject is inserted into a viewing port at one end of a light-tight housing containing various optical assemblies. Visual acuity and other refractive characteristics and ocular muscle balance characteristics of the eyes of the subject are tested by means of a retractable phoroptor assembly carried near the viewing port and a film cassette unit carried in the rearward portion of the housing (the latter selectively providing a variety of different visual targets which are viewed through the optical system of the phoroptor assembly). The visual dark adaptation characteristics and absolute brightness threshold of the subject are tested by means of a projector assembly which selectively projects one or both of a variable intensity fixation target and a variable intensity adaptation test field onto a viewing screen located near the top of the housing.
... around or behind the eye Diabetes Horner syndrome Myasthenia gravis Stroke Swelling in the eyelid, such as with ... performed include: Slit-lamp examination Tension test for myasthenia gravis Visual field testing
ERIC Educational Resources Information Center
Brooks, Brian E.; Cooper, Eric E.
2006-01-01
Three divided visual field experiments tested current hypotheses about the types of visual shape representation tasks that recruit the cognitive and neural mechanisms underlying face recognition. Experiment 1 found a right hemisphere advantage for subordinate but not basic-level face recognition. Experiment 2 found a right hemisphere advantage for…
2008-07-01
for the redesign of the previously fielded 66mm M76 grenade. Although the M76 grenades provided effective screening in the visual and thermal IR...Environmental and Field Testing Team, Engineering Directorate (ECBC), for coordinating and transporting the test items to the downrange testing site and to...13 2.2 Experimental Design-Downrange Testing ............................................. 14 2.3
NASA Astrophysics Data System (ADS)
Glickman, Randolph D.; Harrison, Joseph M.; Zwick, Harry; Longbotham, Harold G.; Ballentine, Charles S.; Pierce, Bennie
1996-04-01
Although visual function following retinal laser injuries has traditionally been assessed by measuring visual acuity, this measure only indicates the highest spatial frequency resolvable under high-contrast viewing conditions. Another visual psychophysical parameter is contrast sensitivity (CS), which measures the minimum contrast required for detection of targets over a range of spatial frequencies, and may evaluate visual mechanisms that do not directly subserve acuity. We used the visual evoked potential (VEP) to measure CS in a population of normal subjects and in patients with ophthalmic conditions affecting retinal function, including one patient with a laser injury in the macula. In this patient, the acuity had recovered from
Relationship between Functional Visual Acuity and Useful Field of View in Elderly Drivers
Negishi, Kazuno; Masui, Sachiko; Mimura, Masaru; Fujita, Yoshio; Tsubota, Kazuo
2016-01-01
Purpose To investigate the relationship between the functional visual acuity (FVA) and useful field of view (UFOV) in elderly drivers and assess the usefulness of the FVA test to screen driving aptitude in elderly drivers. Methods This study included 45 elderly drivers (31 men, 14 women; mean age, 68.1 years) and 30 younger drivers (26 men, 4 women; mean age, 34.2 years) who drive regularly. All participants underwent measurement of the binocular corrected distant visual acuity (CDVA), binocular corrected distant FVA (CDFVA), and Visual Field with Inhibitory Tasks Elderly Version (VFIT-EV) to measure UFOV. The tear function and cognitive status also were evaluated. Results The CDVA, the CDFVA, cognitive status, and the correct response rate (CAR) of the VFIT-EV were significantly worse in the elderly group than in the control group (P = 0.000 for all parameters). The cognitive status was correlated significantly with the CDVA (r = -0.301, P = 0.009), CDFVA (r = -0.402, P = 0.000), and the CAR of the VFIT-EV (r = 0.348, P = 0.002) in all subjects. The results of the tear function tests were not correlated with the CDVA, CDFVA, or VFIT-EV in any subjects. Stepwise regression analysis for all subjects in the elderly and control groups showed that the CDFVA predicted the CAR most significantly among the clinical factors evaluated. Conclusion The FVA test is a promising method to screen the driving aptitude, including both visual and cognitive functions, in a short time. PMID:26808364
Visual Field Outcomes for the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT).
Wall, Michael; Johnson, Chris A; Cello, Kimberly E; Zamba, K D; McDermott, Michael P; Keltner, John L
2016-03-01
The Idiopathic Intracranial Hypertension Treatment Trial (IIHTT) showed that acetazolamide provided a modest, significant improvement in mean deviation (MD). Here, we further analyze visual field changes over the 6-month study period. Of 165 subjects with mild visual loss in the IIHTT, 125 had perimetry at baseline and 6 months. We evaluated pointwise linear regression of visual sensitivity versus time to classify test locations in the worst MD (study) eye as improving or not; pointwise changes from baseline to month 6 in decibels; and clinical consensus of change from baseline to 6 months. The average study eye had 36 of 52 test locations with improving sensitivity over 6 months using pointwise linear regression, but differences between the acetazolamide and placebo groups were not significant. Pointwise results mostly improved in both treatment groups with the magnitude of the mean change within groups greatest and statistically significant around the blind spot and the nasal area, especially in the acetazolamide group. The consensus classification of visual field change from baseline to 6 months in the study eye yielded percentages (acetazolamide, placebo) of 7.2% and 17.5% worse, 35.1% and 31.7% with no change, and 56.1% and 50.8% improved; group differences were not statistically significant. In the IIHTT, compared to the placebo group, the acetazolamide group had a significant pointwise improvement in visual field function, particularly in the nasal and pericecal areas; the latter is likely due to reduction in blind spot size related to improvement in papilledema. (ClinicalTrials.gov number, NCT01003639.).
Individual differences in the shape of the nasal visual field.
Swanson, William H; Dul, Mitchell W; Horner, Douglas G; Malinovsky, Victor E
2017-12-01
Between-subject differences in the shape of the nasal visual field were assessed for 103 volunteers 21-85years of age and free of visual disorder. Perimetry was conducted with a stimulus for which contrast sensitivity is minimally affected by peripheral defocus and decreased retinal illumination. One eye each was tested for 103 volunteers free of eye disease in a multi-center prospective longitudinal study. A peripheral deviation index was computed as the difference in log contrast sensitivity at outer (25-29° nasal) and inner (8° from fixation) locations. Values for this index ranged from 0.01 (outer sensitivity slightly greater than inner sensitivity) to -0.7 log unit (outer sensitivity much lower than inner sensitivity). Mean sensitivity for the inner locations was independent of the deviation index (R 2 <1%), while mean sensitivity for the outer locations was not (R 2 =38%, p<0.0005). Age was only modestly related to the index, with a decline by 0.017 log unit per decade (R 2 =10%). Test-retest data for 21 volunteers who completed 7-10 visits yielded standard deviations for the index from 0.04 to 0.17 log unit, with a mean of 0.09 log unit. Between-subject differences in peripheral deviation persisted over two years of longitudinal testing. Peripheral deviation indices were correlated with indices for three other perimetric stimuli used in a subset of 24 volunteers (R 2 from 20% to 49%). Between-subject variability in shape of the visual field raises concerns about current clinical visual field indices, and further studies are needed to develop improved indices. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
On-Road Driving Performance by Persons with Hemianopia and Quadrantanopia
Wood, Joanne M.; McGwin, Gerald; Elgin, Jennifer; Vaphiades, Michael S.; Braswell, Ronald A.; DeCarlo, Dawn K.; Kline, Lanning B.; Meek, G. Christine; Searcey, Karen; Owsley, Cynthia
2009-01-01
Purpose This study was designed to examine the on-road driving performance of drivers with hemianopia and quadrantanopia compared with age-matched controls. Methods Participants included persons with hemianopia or quadrantanopia and those with normal visual fields. Visual and cognitive function tests were administered, including confirmation of hemianopia and quadrantanopia through visual field testing. Driving performance was assessed using a dual-brake vehicle and monitored by a certified driving rehabilitation specialist. The route was 14.1 miles of city and interstate driving. Two “back-seat” evaluators masked to drivers’ clinical characteristics independently assessed driving performance using a standard scoring system. Results Participants were 22 persons with hemianopia and 8 with quadrantanopia (mean age, 53 ± 20 years) and 30 participants with normal fields (mean age, 52 ± 19 years). Inter-rater agreement for back-seat evaluators was 96%. All drivers with normal fields were rated as safe to drive, while 73% (16/22) of hemianopic and 88% (7/8) of quadrantanopic drivers received safe ratings. Drivers with hemianopia or quadrantanopia who displayed on-road performance problems tended to have difficulty with lane position, steering steadiness, and gap judgment compared to controls. Clinical characteristics associated with unsafe driving were slowed visual processing speed, reduced contrast sensitivity and visual field sensitivity. Conclusions Some drivers with hemianopia or quadrantanopia are fit to drive compared with age-matched control drivers. Results call into question the fairness of governmental policies that categorically deny licensure to persons with hemianopia or quadrantanopia without the opportunity for on-road evaluation. PMID:18936138
Distinct regions of the hippocampus are associated with memory for different spatial locations.
Jeye, Brittany M; MacEvoy, Sean P; Karanian, Jessica M; Slotnick, Scott D
2018-05-15
In the present functional magnetic resonance imaging (fMRI) study, we aimed to evaluate whether distinct regions of the hippocampus were associated with spatial memory for items presented in different locations of the visual field. In Experiment 1, during the study phase, participants viewed abstract shapes in the left or right visual field while maintaining central fixation. At test, old shapes were presented at fixation and participants classified each shape as previously in the "left" or "right" visual field followed by an "unsure"-"sure"-"very sure" confidence rating. Accurate spatial memory for shapes in the left visual field was isolated by contrasting accurate versus inaccurate spatial location responses. This contrast produced one hippocampal activation in which the interaction between item type and accuracy was significant. The analogous contrast for right visual field shapes did not produce activity in the hippocampus; however, the contrast of high confidence versus low confidence right-hits produced one hippocampal activation in which the interaction between item type and confidence was significant. In Experiment 2, the same paradigm was used but shapes were presented in each quadrant of the visual field during the study phase. Accurate memory for shapes in each quadrant, exclusively masked by accurate memory for shapes in the other quadrants, produced a distinct activation in the hippocampus. A multi-voxel pattern analysis (MVPA) of hippocampal activity revealed a significant correlation between behavioral spatial location accuracy and hippocampal MVPA accuracy across participants. The findings of both experiments indicate that distinct hippocampal regions are associated with memory for different visual field locations. Copyright © 2018 Elsevier B.V. All rights reserved.
Levine, Richard A.; Demirel, Shaban; Fan, Juanjuan; Keltner, John L.; Johnson, Chris A.; Kass, Michael A.
2007-01-01
Purpose To evaluate whether baseline visual field data and asymmetries between eyes predict the onset of primary open-angle glaucoma (POAG) in Ocular Hypertension Treatment Study (OHTS) participants. Methods A new index, mean prognosis (MP), was designed for optimal combination of visual field thresholds, to discriminate between eyes that developed POAG from eyes that did not. Baseline intraocular pressure (IOP) in fellow eyes was used to construct measures of IOP asymmetry. Age-adjusted baseline thresholds were used to develop indicators of visual field asymmetry and summary measures of visual field defects. Marginal multivariate failure time models were constructed that relate the new index MP, IOP asymmetry, and visual field asymmetry to POAG onset for OHTS participants. Results The marginal multivariate failure time analysis showed that the MP index is significantly related to POAG onset (P < 0.0001) and appears to be a more highly significant predictor of POAG onset than either mean deviation (MD; P = 0.17) or pattern standard deviation (PSD; P = 0.046). A 1-mm Hg increase in IOP asymmetry between fellow eyes is associated with a 17% increase in risk for development of POAG. When threshold asymmetry between eyes existed, the eye with lower thresholds was at a 37% greater risk of development of POAG, and this feature was more predictive of POAG onset than the visual field index MD, though not as strong a predictor as PSD. Conclusions The MP index, IOP asymmetry, and binocular test point asymmetry can assist in clinical evaluation of eyes at risk of development of POAG. PMID:16936102
Relationship among visual field, blood flow, and neural structure measurements in glaucoma.
Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David
2012-05-17
To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.
Margolin, Edward; Gujar, Sachin K; Trobe, Jonathan D
2007-12-01
A 16-year-old boy who was briefly asystolic and hypotensive after a motor vehicle accident complained of abnormal vision after recovering consciousness. Visual acuity was normal, but visual fields were severely constricted without clear hemianopic features. The ophthalmic examination was otherwise normal. Brain MRI performed 11 days after the accident showed no pertinent abnormalities. At 6 months after the event, brain MRI demonstrated brain volume loss in the primary visual cortex and no other abnormalities. One year later, visual fields remained severely constricted; neurologic examination, including formal neuropsychometric testing, was normal. This case emphasizes the fact that hypoxic-ischemic encephalopathy (HIE) may cause enduring damage limited to primary visual cortex and that the MRI abnormalities may be subtle. These phenomena should be recognized in the management of patients with HIE.
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
Bao, Yan; Lei, Quan; Fang, Yuan; Tong, Yu; Schill, Kerstin; Pöppel, Ernst; Strasburger, Hans
2013-01-01
Inhibition of return (IOR) as an indicator of attentional control is characterized by an eccentricity effect, that is, the more peripheral visual field shows a stronger IOR magnitude relative to the perifoveal visual field. However, it could be argued that this eccentricity effect may not be an attention effect, but due to cortical magnification. To test this possibility, we examined this eccentricity effect in two conditions: the same-size condition in which identical stimuli were used at different eccentricities, and the size-scaling condition in which stimuli were scaled according to the cortical magnification factor (M-scaling), thus stimuli being larger at the more peripheral locations. The results showed that the magnitude of IOR was significantly stronger in the peripheral relative to the perifoveal visual field, and this eccentricity effect was independent of the manipulation of stimulus size (same-size or size-scaling). These results suggest a robust eccentricity effect of IOR which cannot be eliminated by M-scaling. Underlying neural mechanisms of the eccentricity effect of IOR are discussed with respect to both cortical and subcortical structures mediating attentional control in the perifoveal and peripheral visual field.
Visual function and fitness to drive.
Kotecha, Aachal; Spratt, Alexander; Viswanathan, Ananth
2008-01-01
Driving is recognized to be a visually intensive task and accordingly there is a legal minimum standard of vision required for all motorists. The purpose of this paper is to review the current United Kingdom (UK) visual requirements for driving and discuss the evidence base behind these legal rules. The role of newer, alternative tests of visual function that may be better indicators of driving safety will also be considered. Finally, the implications of ageing on driving ability are discussed. A search of Medline and PubMed databases was performed using the following keywords: driving, vision, visual function, fitness to drive and ageing. In addition, papers from the Department of Transport website and UK Royal College of Ophthalmologists guidelines were studied. Current UK visual standards for driving are based upon historical concepts, but recent advances in technology have brought about more sophisticated methods for assessing the status of the binocular visual field and examining visual attention. These tests appear to be better predictors of driving performance. Further work is required to establish whether these newer tests should be incorporated in the current UK visual standards when examining an individual's fitness to drive.
Visual recovery in cortical blindness is limited by high internal noise
Cavanaugh, Matthew R.; Zhang, Ruyuan; Melnick, Michael D.; Das, Anasuya; Roberts, Mariel; Tadin, Duje; Carrasco, Marisa; Huxlin, Krystel R.
2015-01-01
Damage to the primary visual cortex typically causes cortical blindness (CB) in the hemifield contralateral to the damaged hemisphere. Recent evidence indicates that visual training can partially reverse CB at trained locations. Whereas training induces near-complete recovery of coarse direction and orientation discriminations, deficits in fine motion processing remain. Here, we systematically disentangle components of the perceptual inefficiencies present in CB fields before and after coarse direction discrimination training. In seven human CB subjects, we measured threshold versus noise functions before and after coarse direction discrimination training in the blind field and at corresponding intact field locations. Threshold versus noise functions were analyzed within the framework of the linear amplifier model and the perceptual template model. Linear amplifier model analysis identified internal noise as a key factor differentiating motion processing across the tested areas, with visual training reducing internal noise in the blind field. Differences in internal noise also explained residual perceptual deficits at retrained locations. These findings were confirmed with perceptual template model analysis, which further revealed that the major residual deficits between retrained and intact field locations could be explained by differences in internal additive noise. There were no significant differences in multiplicative noise or the ability to process external noise. Together, these results highlight the critical role of altered internal noise processing in mediating training-induced visual recovery in CB fields, and may explain residual perceptual deficits relative to intact regions of the visual field. PMID:26389544
Visual functions and disability in diabetic retinopathy patients
Shrestha, Gauri Shankar; Kaiti, Raju
2013-01-01
Purpose This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. Method A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. Result The majority of subjects (42.1%) were of the age group 60–70 years. Best corrected visual acuity was found to be 0.73 ± 0.2 in the better eye and 0.93 ± 0.27 in the worse eye, which was significantly different at p = 0.002. Visual disability scores were significantly higher for legibility of letters (1.2 ± 0.3) and sentences (1.4 ± 0.4), and least for clothing (0.7 ± 0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Conclusion Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. PMID:24646899
Visual functions and disability in diabetic retinopathy patients.
Shrestha, Gauri Shankar; Kaiti, Raju
2014-01-01
This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. The majority of subjects (42.1%) were of the age group 60-70 years. Best corrected visual acuity was found to be 0.73±0.2 in the better eye and 0.93±0.27 in the worse eye, which was significantly different at p=0.002. Visual disability scores were significantly higher for legibility of letters (1.2±0.3) and sentences (1.4±0.4), and least for clothing (0.7±0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Foerster, Rebecca M.; Poth, Christian H.; Behler, Christian; Botsch, Mario; Schneider, Werner X.
2016-01-01
Neuropsychological assessment of human visual processing capabilities strongly depends on visual testing conditions including room lighting, stimuli, and viewing-distance. This limits standardization, threatens reliability, and prevents the assessment of core visual functions such as visual processing speed. Increasingly available virtual reality devices allow to address these problems. One such device is the portable, light-weight, and easy-to-use Oculus Rift. It is head-mounted and covers the entire visual field, thereby shielding and standardizing the visual stimulation. A fundamental prerequisite to use Oculus Rift for neuropsychological assessment is sufficient test-retest reliability. Here, we compare the test-retest reliabilities of Bundesen’s visual processing components (visual processing speed, threshold of conscious perception, capacity of visual working memory) as measured with Oculus Rift and a standard CRT computer screen. Our results show that Oculus Rift allows to measure the processing components as reliably as the standard CRT. This means that Oculus Rift is applicable for standardized and reliable assessment and diagnosis of elementary cognitive functions in laboratory and clinical settings. Oculus Rift thus provides the opportunity to compare visual processing components between individuals and institutions and to establish statistical norm distributions. PMID:27869220
Foerster, Rebecca M; Poth, Christian H; Behler, Christian; Botsch, Mario; Schneider, Werner X
2016-11-21
Neuropsychological assessment of human visual processing capabilities strongly depends on visual testing conditions including room lighting, stimuli, and viewing-distance. This limits standardization, threatens reliability, and prevents the assessment of core visual functions such as visual processing speed. Increasingly available virtual reality devices allow to address these problems. One such device is the portable, light-weight, and easy-to-use Oculus Rift. It is head-mounted and covers the entire visual field, thereby shielding and standardizing the visual stimulation. A fundamental prerequisite to use Oculus Rift for neuropsychological assessment is sufficient test-retest reliability. Here, we compare the test-retest reliabilities of Bundesen's visual processing components (visual processing speed, threshold of conscious perception, capacity of visual working memory) as measured with Oculus Rift and a standard CRT computer screen. Our results show that Oculus Rift allows to measure the processing components as reliably as the standard CRT. This means that Oculus Rift is applicable for standardized and reliable assessment and diagnosis of elementary cognitive functions in laboratory and clinical settings. Oculus Rift thus provides the opportunity to compare visual processing components between individuals and institutions and to establish statistical norm distributions.
Integration of real-time 3D capture, reconstruction, and light-field display
NASA Astrophysics Data System (ADS)
Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao
2015-03-01
Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.
Li, Li; Xiong, De-fu; Liu, Jia-wen; Li, Zi-xin; Zeng, Guang-cheng; Li, Hua-liang
2014-03-01
We aimed to evaluate the interference of 50 Hz extremely low frequency electromagnetic field (ELF-EMF) occupational exposure on the neurobehavior tests of workers performing tour-inspection close to transformers and distribution power lines. Occupational short-term "spot" measurements were carried out. 310 inspection workers and 300 logistics staff were selected as exposure and control. The neurobehavior tests were performed through computer-based neurobehavior evaluation system, including mental arithmetic, curve coincide, simple visual reaction time, visual retention, auditory digit span and pursuit aiming. In 500 kV areas electric field intensity at 71.98% of total measured 590 spots were above 5 kV/m (national occupational standard), while in 220 kV areas electric field intensity at 15.69% of total 701 spots were above 5 kV/m. Magnetic field flux density at all the spots was below 1,000 μT (ICNIRP occupational standard). The neurobehavior score changes showed no statistical significance. Results of neurobehavior tests among different age, seniority groups showed no significant changes. Neurobehavior changes caused by daily repeated ELF-EMF exposure were not observed in the current study.
NASA Astrophysics Data System (ADS)
Deratzou, Susan
This research studies the process of high school chemistry students visualizing chemical structures and its role in learning chemical bonding and molecular structure. Minimal research exists with high school chemistry students and more research is necessary (Gabel & Sherwood, 1980; Seddon & Moore, 1986; Seddon, Tariq, & Dos Santos Veiga, 1984). Using visualization tests (Ekstrom, French, Harman, & Dermen, 1990a), a learning style inventory (Brown & Cooper, 1999), and observations through a case study design, this study found visual learners performed better, but needed more practice and training. Statistically, all five pre- and post-test visualization test comparisons were highly significant in the two-tailed t-test (p > .01). The research findings are: (1) Students who tested high in the Visual (Language and/or Numerical) and Tactile Learning Styles (and Social Learning) had an advantage. Students who learned the chemistry concepts more effectively were better at visualizing structures and using molecular models to enhance their knowledge. (2) Students showed improvement in learning after visualization practice. Training in visualization would improve students' visualization abilities and provide them with a way to think about these concepts. (3) Conceptualization of concepts indicated that visualizing ability was critical and that it could be acquired. Support for this finding was provided by pre- and post-Visualization Test data with a highly significant t-test. (4) Various molecular animation programs and websites were found to be effective. (5) Visualization and modeling of structures encompassed both two- and three-dimensional space. The Visualization Test findings suggested that the students performed better with basic rotation of structures as compared to two- and three-dimensional objects. (6) Data from observations suggest that teaching style was an important factor in student learning of molecular structure. (7) Students did learn the chemistry concepts. Based on the Visualization Test results, which showed that most of the students performed better on the post-test, the visualization experience and the abstract nature of the content allowed them to transfer some of their chemical understanding and practice to non-chemical structures. Finally, implications for teaching of chemistry, students learning chemistry, curriculum, and research for the field of chemical education were discussed.
Training improves reading speed in peripheral vision: is it due to attention?
Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J
2010-06-01
Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.
Ragan, Eric D.; Bowman, Doug A.; Kopper, Regis; ...
2015-02-13
Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highestmore » level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.« less
Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.
Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio
2015-01-01
In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.
The multiple sclerosis visual pathway cohort: understanding neurodegeneration in MS.
Martínez-Lapiscina, Elena H; Fraga-Pumar, Elena; Gabilondo, Iñigo; Martínez-Heras, Eloy; Torres-Torres, Ruben; Ortiz-Pérez, Santiago; Llufriu, Sara; Tercero, Ana; Andorra, Magi; Roca, Marc Figueras; Lampert, Erika; Zubizarreta, Irati; Saiz, Albert; Sanchez-Dalmau, Bernardo; Villoslada, Pablo
2014-12-15
Multiple Sclerosis (MS) is an immune-mediated disease of the Central Nervous System with two major underlying etiopathogenic processes: inflammation and neurodegeneration. The latter determines the prognosis of this disease. MS is the main cause of non-traumatic disability in middle-aged populations. The MS-VisualPath Cohort was set up to study the neurodegenerative component of MS using advanced imaging techniques by focusing on analysis of the visual pathway in a middle-aged MS population in Barcelona, Spain. We started the recruitment of patients in the early phase of MS in 2010 and it remains permanently open. All patients undergo a complete neurological and ophthalmological examination including measurements of physical and disability (Expanded Disability Status Scale; Multiple Sclerosis Functional Composite and neuropsychological tests), disease activity (relapses) and visual function testing (visual acuity, color vision and visual field). The MS-VisualPath protocol also assesses the presence of anxiety and depressive symptoms (Hospital Anxiety and Depression Scale), general quality of life (SF-36) and visual quality of life (25-Item National Eye Institute Visual Function Questionnaire with the 10-Item Neuro-Ophthalmic Supplement). In addition, the imaging protocol includes both retinal (Optical Coherence Tomography and Wide-Field Fundus Imaging) and brain imaging (Magnetic Resonance Imaging). Finally, multifocal Visual Evoked Potentials are used to perform neurophysiological assessment of the visual pathway. The analysis of the visual pathway with advance imaging and electrophysilogical tools in parallel with clinical information will provide significant and new knowledge regarding neurodegeneration in MS and provide new clinical and imaging biomarkers to help monitor disease progression in these patients.
Rebolledo-Solleiro, Daniela; Crespo-Ramírez, Minerva; Roldán-Roldán, Gabriel; Hiriart, Marcia; Pérez de la Mora, Miguel
2013-08-15
Conflicting results have been obtained by several groups when studying the effects of streptozotocin (STZ)-treated rats in the elevated plus-maze (EPM). Since thirst is a prominent feature in STZ-induced diabetic-like condition, we studied whether the walls of the closed arms of the EPM, by limiting the search for water in the environment, may contribute to the observed differential behavioral outcomes. The aim of this study was to ascertain whether visual barriers within the EPM have an influence on the behavior of STZ-treated rats in this test of anxiety. A striking similarity between STZ-treated (50 mg/kg, i.p., in two consecutive days) and water deprived rats (72 h) was found in exploratory behavior in the EPM, showing an anxiolytic-like profile. However the anxiolytic response of STZ-treated rats exposed to the EPM shifts into an anxiogenic profile when they are subsequently tested in the open-field test, which unlike the EPM is devoid of visual barriers. Likewise, water deprived rats (72 h) also showed an anxiogenic profile when they were exposed to the open-field test. Our results indicate that experimental outcomes based on EPM observations can be misleading when studying physiological or pathological conditions, e.g. diabetes, in which thirst may increase exploratory behavior. © 2013.
Melis-Dankers, Bart J. M.; Brouwer, Wiebo H.; Tucha, Oliver; Heutink, Joost
2016-01-01
Introduction People with homonymous visual field defects (HVFD) often report difficulty detecting obstacles in the periphery on their blind side in time when moving around. Recently, a randomized controlled trial showed that the InSight-Hemianopia Compensatory Scanning Training (IH-CST) specifically improved detection of peripheral stimuli and avoiding obstacles when moving around, especially in dual task situations. Method The within-group training effects of the previously reported IH-CST are examined in an extended patient group. Performance of patients with HVFD on a pre-assessment, post-assessment and follow-up assessment and performance of a healthy control group are compared. Furthermore, it is examined whether training effects can be predicted by demographic characteristics, variables related to the visual disorder, and neuropsychological test results. Results Performance on both subjective and objective measures of mobility-related scanning was improved after training, while no evidence was found for improvement in visual functions (including visual fields), reading, visual search and dot counting. Self-reported improvement did not correlate with improvement in objective mobility performance. According to the participants, the positive effects were still present six to ten months after training. No demographic characteristics, variables related to the visual disorder, and neuropsychological test results were found to predict the size of training effect, although some inconclusive evidence was found for more improvement in patients with left-sided HVFD than in patients with right-sided HFVD. Conclusion Further support was found for a positive effect of IH-CST on detection of visual stimuli during mobility-related activities specifically. Based on the reports given by patients, these effects appear to be long-term effects. However, no conclusions can be drawn on the objective long-term training effects. PMID:27935973
O'Leary, Neil; Chauhan, Balwantray C; Artes, Paul H
2012-10-01
To establish a method for estimating the overall statistical significance of visual field deterioration from an individual patient's data, and to compare its performance to pointwise linear regression. The Truncated Product Method was used to calculate a statistic S that combines evidence of deterioration from individual test locations in the visual field. The overall statistical significance (P value) of visual field deterioration was inferred by comparing S with its permutation distribution, derived from repeated reordering of the visual field series. Permutation of pointwise linear regression (PoPLR) and pointwise linear regression were evaluated in data from patients with glaucoma (944 eyes, median mean deviation -2.9 dB, interquartile range: -6.3, -1.2 dB) followed for more than 4 years (median 10 examinations over 8 years). False-positive rates were estimated from randomly reordered series of this dataset, and hit rates (proportion of eyes with significant deterioration) were estimated from the original series. The false-positive rates of PoPLR were indistinguishable from the corresponding nominal significance levels and were independent of baseline visual field damage and length of follow-up. At P < 0.05, the hit rates of PoPLR were 12, 29, and 42%, at the fifth, eighth, and final examinations, respectively, and at matching specificities they were consistently higher than those of pointwise linear regression. In contrast to population-based progression analyses, PoPLR provides a continuous estimate of statistical significance for visual field deterioration individualized to a particular patient's data. This allows close control over specificity, essential for monitoring patients in clinical practice and in clinical trials.
Dye, Matthew W G; Seymour, Jenessa L; Hauser, Peter C
2016-04-01
Deafness results in cross-modal plasticity, whereby visual functions are altered as a consequence of a lack of hearing. Here, we present a reanalysis of data originally reported by Dye et al. (PLoS One 4(5):e5640, 2009) with the aim of testing additional hypotheses concerning the spatial redistribution of visual attention due to deafness and the use of a visuogestural language (American Sign Language). By looking at the spatial distribution of errors made by deaf and hearing participants performing a visuospatial selective attention task, we sought to determine whether there was evidence for (1) a shift in the hemispheric lateralization of visual selective function as a result of deafness, and (2) a shift toward attending to the inferior visual field in users of a signed language. While no evidence was found for or against a shift in lateralization of visual selective attention as a result of deafness, a shift in the allocation of attention from the superior toward the inferior visual field was inferred in native signers of American Sign Language, possibly reflecting an adaptation to the perceptual demands imposed by a visuogestural language.
Goffeng, Lars Ole; Kjuus, Helge; Heier, Mona Skard; Alvestrand, Monica; Ulvestad, Bente; Skaug, Vidar
2008-01-01
The aim of the study was to examine possible persisting visual system effects in tunnel workers previously exposed to acrylamide and N-methylolacrylamide during grouting work. Visual field light sensitivity threshold and colour vision has been examined among 44 tunnel workers 2-10 years after exposure to acrylamide and N-methylolacrylamide containing grouting agents. Forty-four tunnel workers not involved in grouting operations served as control group. Information on exposure and background variables was obtained for all participants from a questionnaire. Visual light sensitivity threshold was measured using Humphrey Visual Field Static Perimeter 740, program 30-2 Fastpack, with red stimuli on white background, and colour vision, using Lanthony D-15 Desaturated Color test. Based on D-15d test results, colour confusion index (CCI), and a severity index (C-index) was calculated. The exposed group had a significantly higher threshold for detecting single stimuli in all parts of the inner 30 degrees of the visual field compared to the control group. The foveal threshold group difference was 1.4 dB (p=0.002) (mean value, both eyes). On the Lanthony 15 Hue Desaturated test, the exposed subjects made more errors in sorting blue colours, and a statistically significant increase in C-index was observed. Surrogate measures for duration and intensity of exposure gave no further improvement of the model. The results indicate slightly reduced light sensitivity and reduced colour discrimination among the exposed subjects compared to the controls. The findings may be due to previous exposure to acrylamide containing grouts among the tunnel workers.
Is vision function related to physical functional ability in older adults?
West, Catherine G; Gildengorin, Ginny; Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E; Lott, Lori; Brabyn, John A
2002-01-01
To assess the relationship between a broad range of vision functions and measures of physical performance in older adults. Cross-sectional study. Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study. Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95. Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance). The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes. Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.
The effect of contextual cues on the encoding of motor memories.
Howard, Ian S; Wolpert, Daniel M; Franklin, David W
2013-05-01
Several studies have shown that sensory contextual cues can reduce the interference observed during learning of opposing force fields. However, because each study examined a small set of cues, often in a unique paradigm, the relative efficacy of different sensory contextual cues is unclear. In the present study we quantify how seven contextual cues, some investigated previously and some novel, affect the formation and recall of motor memories. Subjects made movements in a velocity-dependent curl field, with direction varying randomly from trial to trial but always associated with a unique contextual cue. Linking field direction to the cursor or background color, or to peripheral visual motion cues, did not reduce interference. In contrast, the orientation of a visual object attached to the hand cursor significantly reduced interference, albeit by a small amount. When the fields were associated with movement in different locations in the workspace, a substantial reduction in interference was observed. We tested whether this reduction in interference was due to the different locations of the visual feedback (targets and cursor) or the movements (proprioceptive). When the fields were associated only with changes in visual display location (movements always made centrally) or only with changes in the movement location (visual feedback always displayed centrally), a substantial reduction in interference was observed. These results show that although some visual cues can lead to the formation and recall of distinct representations in motor memory, changes in spatial visual and proprioceptive states of the movement are far more effective than changes in simple visual contextual cues.
[Are Visual Field Defects Reversible? - Visual Rehabilitation with Brains].
Sabel, B A
2017-02-01
Visual field defects are considered irreversible because the retina and optic nerve do not regenerate. Nevertheless, there is some potential for recovery of the visual fields. This can be accomplished by the brain, which analyses and interprets visual information and is able to amplify residual signals through neuroplasticity. Neuroplasticity refers to the ability of the brain to change its own functional architecture by modulating synaptic efficacy. This is actually the neurobiological basis of normal learning. Plasticity is maintained throughout life and can be induced by repetitively stimulating (training) brain circuits. The question now arises as to how plasticity can be utilised to activate residual vision for the treatment of visual field loss. Just as in neurorehabilitation, visual field defects can be modulated by post-lesion plasticity to improve vision in glaucoma, diabetic retinopathy or optic neuropathy. Because almost all patients have some residual vision, the goal is to strengthen residual capacities by enhancing synaptic efficacy. New treatment paradigms have been tested in clinical studies, including vision restoration training and non-invasive alternating current stimulation. While vision training is a behavioural task to selectively stimulate "relative defects" with daily vision exercises for the duration of 6 months, treatment with alternating current stimulation (30 min. daily for 10 days) activates and synchronises the entire retina and brain. Though full restoration of vision is not possible, such treatments improve vision, both subjectively and objectively. This includes visual field enlargements, improved acuity and reaction time, improved orientation and vision related quality of life. About 70 % of the patients respond to the therapies and there are no serious adverse events. Physiological studies of the effect of alternating current stimulation using EEG and fMRI reveal massive local and global changes in the brain. These include local activation of the visual cortex and global reorganisation of neuronal brain networks. Because modulation of neuroplasticity can strengthen residual vision, the brain deserves a better reputation in ophthalmology for its role in visual rehabilitation. For patients, there is now more light at the end of the tunnel, because vision loss in some areas of the visual field defect is indeed reversible. Georg Thieme Verlag KG Stuttgart · New York.
Guo, Xinxing; Kong, Xiangbin; Huang, Rui; Jin, Ling; Ding, Xiaohu; He, Mingguang; Liu, Xing; Patel, Mehul Chimanlal; Congdon, Nathan G
2014-01-07
We evaluated the effect of ginkgo biloba extract on visual field defect and contrast sensitivity in a Chinese cohort with normal tension glaucoma. In this prospective, randomized, placebo-controlled crossover study, patients newly diagnosed with normal tension glaucoma, either in a tertiary glaucoma clinic (n = 5) or in a cohort undergoing routine general physical examinations in a primary care clinic (n = 30), underwent two 4-week phases of treatment, separated by a washout period of 8 weeks. Randomization determined whether ginkgo biloba extract (40 mg, 3 times per day) or placebo (identical-appearing tablets) was received first. Primary outcomes were change in contrast sensitivity and mean deviation on 24-2 SITA standard visual field testing, while secondary outcomes included IOP and self-reported adverse events. A total of 35 patients with mean age 63.7 (6.5) years were randomized to the ginkgo biloba extract-placebo (n = 18) or the placebo-ginkgo biloba extract (n = 17) sequence. A total of 28 patients (80.0%, 14 in each group) who completed testing did not differ at baseline in age, sex, visual field mean deviation, contrast sensitivity, IOP, or blood pressure. Changes in visual field and contrast sensitivity did not differ by treatment received or sequence (P > 0.2 for all). Power to have detected a difference in mean defect as large as previously reported was 80%. In contrast to some previous reports, ginkgo biloba extract treatment had no effect on mean defect or contrast sensitivity in this group of normal tension glaucoma patients. (http://www.chictr.org number, ChiCTR-TRC-08000724).
Casas, Paula; Ascaso, Francisco J; Vicente, Eugenio; Tejero-Garcés, Gloria; Adiego, María I; Cristóbal, José A
2018-03-02
To assess the retinal sensitivity in obstructive sleep apnea hypopnea syndrome (OSAHS) patients evaluated with standard automated perimetry (SAP). And to correlate the functional SAP results with structural parameters obtained with optical coherence tomography (OCT). This prospective, observational, case-control study consisted of 63 eyes of 63 OSAHS patients (mean age 51.7 ± 12.7 years, best corrected visual acuity ≥20/25, refractive error less than three spherical or two cylindrical diopters, and intraocular pressure < 21 mmHg) who were enrolled and compared with 38 eyes of 38 age-matched controls. Peripapillary retinal nerve fiber layer (RNFL) thickness was measured by Stratus OCT and SAP sensitivities and indices were explored with Humphrey Field Analyzer perimeter. Correlations between functional and structural parameters were calculated, as well as the relationship between ophthalmologic and systemic indices in OSAHS patients. OSAHS patients showed a significant reduction of the sensitivity for superior visual field division (p = 0.034, t-student test). When dividing the OSAHS group in accordance with the severity of the disease, nasal peripapillary RNFL thickness was significantly lower in severe OSAHS than that in controls and mild-moderate cases (p = 0.031 and p = 0.016 respectively, Mann-Whitney U test). There were no differences between groups for SAP parameters. We found no correlation between structural and functional variables. The central visual field sensitivity of the SAP revealed a poor Pearson correlation with the apnea-hipopnea index (0.284, p = 0.024). Retinal sensitivity show minor differences between healthy subjects and OSAHS. Functional deterioration in OSAHS patients is not easy to demonstrate with visual field examination.
Adhikarla, Vamsi Kiran; Sodnik, Jaka; Szolgay, Peter; Jakus, Grega
2015-04-14
This paper reports on the design and evaluation of direct 3D gesture interaction with a full horizontal parallax light field display. A light field display defines a visual scene using directional light beams emitted from multiple light sources as if they are emitted from scene points. Each scene point is rendered individually resulting in more realistic and accurate 3D visualization compared to other 3D displaying technologies. We propose an interaction setup combining the visualization of objects within the Field Of View (FOV) of a light field display and their selection through freehand gesture tracked by the Leap Motion Controller. The accuracy and usefulness of the proposed interaction setup was also evaluated in a user study with test subjects. The results of the study revealed high user preference for free hand interaction with light field display as well as relatively low cognitive demand of this technique. Further, our results also revealed some limitations and adjustments of the proposed setup to be addressed in future work.
MACULAR COLOBOMA IN A CHILD WITH USHER SYNDROME.
Ishaq, Mazhar; Mukhtar, Ahsan; Khan, Saim
2015-01-01
Macular coloboma is a rare entity and its concomitance with Usher syndrome is described here. A 14 years male child was studied in detail along with other family members. He underwent two complete ophthalmologic examinations (4-years follow-up), including visual assessment, orthoptic evaluation, colour vision test, visual fields, corneal topography, Optical coherence tomography, fluorescein angiography, and electroretinography. Detailed ophthalmic examination was also conducted on other asymptomatic members of the same family. Patient had sensorineural deafness, poor visual acuity, and progressive visual field impairment in both eyes, bilaterally presenting macular coloboma and atypical retinitis pigmentosa pattern. The other investigated relatives did not show any specific and/or significant ocular disorder. This concurrence represents no genetic pattern and is observed in sporadic cases.
Purtscher's retinopathy associated with acute pancreatitis.
Hamp, Ania M; Chu, Edward; Slagle, William S; Hamp, Robert C; Joy, Jeffrey T; Morris, Robert W
2014-02-01
Purtscher's retinopathy is a rare condition that is associated with complement-activating systemic diseases such as acute pancreatitis. After pancreatic injury or inflammation, proteases such as trypsin activate the complement system and can potentially cause coagulation and leukoembolization of retinal precapillary arterioles. Specifically, intermediate-sized emboli are sufficiently small enough to pass through larger arteries yet large enough to remain lodged in precapillary arterioles and cause the clinical appearance of Purtscher's retinopathy. This pathology may present with optic nerve edema, impaired visual acuity, visual field loss, as well as retinal findings such as cotton-wool spots, retinal hemorrhage, artery attenuation, venous dilation, and Purtscher flecken. A 57-year-old white man presented with an acute onset of visual field scotomas and decreased visual acuity 1 week after being hospitalized for acute pancreatitis. The retinal examination revealed multiple regions of discrete retinal whitening surrounding the disk, extending through the macula bilaterally, as well as bilateral optic nerve hemorrhages. The patient identified paracentral bilateral visual field defects on Amsler Grid testing, which was confirmed with subsequent Humphrey visual field analysis. Although the patient presented with an atypical underlying etiology, he exhibited classic retinal findings for Purtscher's retinopathy. After 2 months, best corrected visual acuity improved and the retinal whitening was nearly resolved; however, bilateral paracentral visual field defects remained. Purtscher's retinopathy has a distinctive clinical presentation and is typically associated with thoracic trauma but may be a sequela of nontraumatic systemic disease such as acute pancreatitis. Patients diagnosed with acute pancreatitis should have an eye examination to rule out Purtscher's retinopathy. Although visual improvement is possible, patients should be educated that there may be permanent ocular sequelae.
Metamorphopsia Score and Central Visual Field Outcomes in Diabetic Cystoid Macular Edema
Brzozowska, Agnieszka; Maciejewski, Ryszard
2018-01-01
Aim To detect abnormality of the visual function in naïve patients with cystoid diabetic macular edema (DME) using M-charts, Amsler test, and white on white (W/W) and blue on yellow (B/Y) perimetry. Methods There were 64 eyes included in the study: 30 eyes with DME, 22 eyes with diabetes without DME, and 12 eyes of normal subjects. Conventional W/W perimetry and B/Y perimetry were performed within the central 10° of the visual field. To assess metamorphopsia, Amsler test and M-charts were used. Results The rate of detection of metamorphopsia was 37% with Amsler test examination and 50% with M-charts. Specificity of both tests was 100%. We found a significant difference between vertical scores of M-charts in all groups, but not in horizontal scores (p < 0.0001). Mean defect (MD) was 8.9 dB and 3.6 dB and loss variance (LV) 4.8 dB and 3.3 dB (p < 0.0001). Conclusions M-chart is more sensitive than Amsler test method for detection of metamorphopsia. The MD and LV are higher in b/y in comparison to W/W perimetry. B/Y perimetry and M-charts are more sensitive than conventional methods for detecting the visual function loss in cystoid DME. PMID:29744359
Doozandeh, Azadeh; Irandoost, Farnoosh; Mirzajani, Ali; Yazdani, Shahin; Pakravan, Mohammad; Esfandiari, Hamed
2017-01-01
This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of defects on pattern deviation (PD) plots were determined. Agreement between two sets regarding the stage of visual field damage was assessed. Pearson's correlation, intra-cluster comparison, paired t-test, and 95% limit of agreement were calculated. Although there was no significant difference between global indices, the agreement between the two devices regarding the global indices was weak (the limit of agreement for mean deviation was -6.08 to 6.08 and that for pattern standard deviation was -4.42 to 3.42). The agreement between SITA-SAP and Matrix-FDT regarding the Glaucoma Hemifield Test (GHT) and the number of defective points in each quadrant and staging of the visual field damage was also weak. Because the correlation between SITA-SAP and Matrix-FDT regarding global indices, GHT, number of defective points, and stage of the visual field damage in mild glaucoma is weak, Matrix-FDT cannot be used interchangeably with SITA-SAP in the early stages of glaucoma.
Heidelberg edge perimeter employment in glaucoma diagnosis--preliminary report.
Mulak, Małgorzata; Szumny, Dorota; Sieja-Bujewska, Anna; Kubrak, Magdalena
2012-01-01
In recent years, the authors have seen huge progress in the diagnosis of eye diseases. One of the new diagnostic devices is HEP (Heidelberg Edge Perimeter) - for early diagnosis of glaucoma and its progression. It combines visual field test and HRT (Heidelberg Retina Tomograph), which allows authors to obtain the image of the mutual relation between the structure and the function of the sight organ. It could be also used to assess patients with impaired retina, optic nerve and neurological deficits. The SAP function is more suitable for the detection and monitoring of neurological deficits, moderately advanced and advanced glaucoma as well as other diseases associated with extensive or deep visual field deficits, such as ischemic optic neuropathy. FDF stimulus was designed specifically to detect early glaucoma-related changes in the visual field. For about a year, the Ophthalmology Clinic in Wrocław has owned a new, unique HEP perimeter. The authors present examples of patients diagnosed and treated at the Clinic, with respect to whom the perimeter results obtained using Octopus type perimeter and HEP contour perimeter have been compared. This method has its advantages: it is non-invasive, objective, provides the opportunity to repeat and compare results obtained from subsequent tests. The disadvantages are the difficulty in adapting to a new stimulus, which is not a circular light stimulus, but an outline that is hard to notice for some patients. Although according to the manufacturer the testing time should not exceed 4-5 minutes, it takes 14-15 minutes in many patients. The test is not suitable for patients showing lower manual skills and less attention and those who tire out easily. The HEP perimeter is an innovative method for diagnosing the earliest changes in ganglion cells, that is pre-perimetric glaucoma, or when changes in the visual field are undetectable in a standard test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abouaf, Lucie; Girard, Nicolas; Claude Bernard University, Lyon
2012-03-01
Purpose: Radiotherapy has shown its efficacy in controlling optic nerve sheath meningiomas (ONSM) tumor growth while allowing visual acuity to improve or stabilize. However, radiation-induced toxicity may ultimately jeopardize the functional benefit. The purpose of this study was to identify predictive factors of poor visual outcome in patients receiving radiotherapy for ONSM. Methods and Materials: We conducted an extensive analysis of 10 patients with ONSM with regard to clinical, radiologic, and dosimetric aspects. All patients were treated with conformal radiotherapy and subsequently underwent biannual neuroophthalmologic and imaging assessments. Pretreatment and posttreatment values of visual acuity and visual field were comparedmore » with Wilcoxon's signed rank test. Results: Visual acuity values significantly improved after radiotherapy. After a median follow-up time of 51 months, 6 patients had improved visual acuity, 4 patients had improved visual field, 1 patient was in stable condition, and 1 patient had deteriorated visual acuity and visual field. Tumor control rate was 100% at magnetic resonance imaging assessment. Visual acuity deterioration after radiotherapy was related to radiation-induced retinopathy in 2 patients and radiation-induced mature cataract in 1 patient. Study of radiotherapy parameters showed that the mean eye dose was significantly higher in those 3 patients who had deteriorated vision. Conclusions: Our study confirms that radiotherapy is efficient in treating ONSM. Long-term visual outcome may be compromised by radiation-induced side effects. Mean eye dose has to be considered as a limiting constraint in treatment planning.« less
Improving visual perception through neurofeedback
Scharnowski, Frank; Hutton, Chloe; Josephs, Oliver; Weiskopf, Nikolaus; Rees, Geraint
2012-01-01
Perception depends on the interplay of ongoing spontaneous activity and stimulus-evoked activity in sensory cortices. This raises the possibility that training ongoing spontaneous activity alone might be sufficient for enhancing perceptual sensitivity. To test this, we trained human participants to control ongoing spontaneous activity in circumscribed regions of retinotopic visual cortex using real-time functional MRI based neurofeedback. After training, we tested participants using a new and previously untrained visual detection task that was presented at the visual field location corresponding to the trained region of visual cortex. Perceptual sensitivity was significantly enhanced only when participants who had previously learned control over ongoing activity were now exercising control, and only for that region of visual cortex. Our new approach allows us to non-invasively and non-pharmacologically manipulate regionally specific brain activity, and thus provide ‘brain training’ to deliver particular perceptual enhancements. PMID:23223302
Development of a Pediatric Visual Field Test
Miranda, Marco A.; Henson, David B.; Fenerty, Cecilia; Biswas, Susmito; Aslam, Tariq
2016-01-01
Purpose We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. Methods The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients' experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4–16 years old) with no history of VF defects were recruited. Results For the 14 subjects completing the study, 31 ± 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 ± 0.3 cd/m2 and 27.9 ± 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher – 8.3 ± 9.0 dB. Conclusions Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Translational Relevance Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population. PMID:27980876
NASA Astrophysics Data System (ADS)
Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.
2017-02-01
Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.
Spatial updating in area LIP is independent of saccade direction.
Heiser, Laura M; Colby, Carol L
2006-05-01
We explore the world around us by making rapid eye movements to objects of interest. Remarkably, these eye movements go unnoticed, and we perceive the world as stable. Spatial updating is one of the neural mechanisms that contributes to this perception of spatial constancy. Previous studies in macaque lateral intraparietal cortex (area LIP) have shown that individual neurons update, or "remap," the locations of salient visual stimuli at the time of an eye movement. The existence of remapping implies that neurons have access to visual information from regions far beyond the classically defined receptive field. We hypothesized that neurons have access to information located anywhere in the visual field. We tested this by recording the activity of LIP neurons while systematically varying the direction in which a stimulus location must be updated. Our primary finding is that individual neurons remap stimulus traces in multiple directions, indicating that LIP neurons have access to information throughout the visual field. At the population level, stimulus traces are updated in conjunction with all saccade directions, even when we consider direction as a function of receptive field location. These results show that spatial updating in LIP is effectively independent of saccade direction. Our findings support the hypothesis that the activity of LIP neurons contributes to the maintenance of spatial constancy throughout the visual field.
NASA Astrophysics Data System (ADS)
Myers, Robert Gardner
1997-12-01
The purpose of this study was to determine whether there is a correlation between the cognitive style of field dependence and the type of visual presentation format used in a computer-based tutorial (color; black and white: or line drawings) when subjects are asked to identify human tissue samples. Two hundred-four college students enrolled in human anatomy and physiology classes at Westmoreland County Community College participated. They were first administered the Group Embedded Figures Test (GEFT) and then were divided into three groups: field-independent (score, 15-18), field-neutral (score, 11-14), and field dependent (score, 0-10). Subjects were randomly assigned to one of the three treatment groups. Instruction was delivered by means of a computer-aided tutorial consisting of text and visuals of human tissue samples. The pretest and posttest consisted of 15 tissue samples, five from each treatment, that were imported into the HyperCardsp{TM} stack and were played using QuickTimesp{TM} movie extensions. A two-way analysis of covariance (ANCOVA) using pretest and posttest scores was used to investigate whether there is a relationship between field dependence and each of the three visual presentation formats. No significant interaction was found between individual subject's relative degree of field dependence and any of the different visual presentation formats used in the computer-aided tutorial module, F(4,194) = 1.78, p =.1335. There was a significant difference between the students' levels of field dependence in terms of their ability to identify human tissue samples, F(2,194) = 5.83, p =.0035. Field-independent subjects scored significantly higher (M = 10.59) on the posttest than subjects who were field-dependent (M = 9.04). There was also a significant difference among the various visual presentation formats, F(2,194) = 3.78, p =.0245. Subjects assigned to the group that received the color visual presentation format scored significantly higher (M = 10.38) on the posttest measure than did those assigned to the group that received the line drawing visual presentation format (8.99).
Woutersen, Karlijn; Guadron, Leslie; van den Berg, Albert V; Boonstra, F Nienke; Theelen, Thomas; Goossens, Jeroen
2017-12-01
The useful-field-of-view (UFOV) test measures the amount of information someone can extract from a visual scene in one glance. Its scores show relatively strong relationships with everyday activities. The UFOV test consists of three computer tests, suggested to measure processing speed and central vision, divided attention, and selective attention. However, other functions seem to be involved as well. In order to investigate the contribution of these suggested and other perceptual and cognitive functions, we performed a meta-analysis of 116 Pearson's correlation coefficients between UFOV scores and other test scores reported in 18 peer-reviewed articles. We divided these correlations into nine domains: attention, executive functioning, general cognition, memory, spatial ability, visual closure, contrast sensitivity, visual processing speed, and visual acuity. A multivariate mixed-effects model analysis revealed that each domain correlated significantly with each of the UFOV subtest scores. These correlations were stronger for Subtests 2 and 3 than for Subtest 1. Furthermore, some domains were more strongly correlated to the UFOV than others across subtests. We did not find interaction effects between subtest and domain, indicating that none of the UFOV subtests is more selectively sensitive to a particular domain than the others. Thus, none of the three UFOV subtests seem to measure one clear construct. Instead, a range of visual and cognitive functions is involved. Perhaps this is the reason for the UFOV's high ecological validity, as it involves many functions at once, making it harder to compensate if one of them fails.
Development and evaluation of vision rehabilitation devices.
Luo, Gang; Peli, Eli
2011-01-01
We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.
Loughman, James; Davison, Peter; Flitcroft, Ian
2007-11-01
Preattentive visual search (PAVS) describes rapid and efficient retinal and neural processing capable of immediate target detection in the visual field. Damage to the nerve fibre layer or visual pathway might reduce the efficiency with which the visual system performs such analysis. The purpose of this study was to test the hypothesis that patients with glaucoma are impaired on parallel search tasks, and that this would serve to distinguish glaucoma in early cases. Three groups of observers (glaucoma patients, suspect and normal individuals) were examined, using computer-generated flicker, orientation, and vertical motion displacement targets to assess PAVS efficiency. The task required rapid and accurate localisation of a singularity embedded in a field of 119 homogeneous distractors on either the left or right-hand side of a computer monitor. All subjects also completed a choice reaction time (CRT) task. Independent sample T tests revealed PAVS efficiency to be significantly impaired in the glaucoma group compared with both normal and suspect individuals. Performance was impaired in all types of glaucoma tested. Analysis between normal and suspect individuals revealed a significant difference only for motion displacement response times. Similar analysis using a PAVS/CRT index confirmed the glaucoma findings but also showed statistically significant differences between suspect and normal individuals across all target types. A test of PAVS efficiency appears capable of differentiating early glaucoma from both normal and suspect cases. Analysis incorporating a PAVS/CRT index enhances the diagnostic capacity to differentiate normal from suspect cases.
Natural image sequences constrain dynamic receptive fields and imply a sparse code.
Häusler, Chris; Susemihl, Alex; Nawrot, Martin P
2013-11-06
In their natural environment, animals experience a complex and dynamic visual scenery. Under such natural stimulus conditions, neurons in the visual cortex employ a spatially and temporally sparse code. For the input scenario of natural still images, previous work demonstrated that unsupervised feature learning combined with the constraint of sparse coding can predict physiologically measured receptive fields of simple cells in the primary visual cortex. This convincingly indicated that the mammalian visual system is adapted to the natural spatial input statistics. Here, we extend this approach to the time domain in order to predict dynamic receptive fields that can account for both spatial and temporal sparse activation in biological neurons. We rely on temporal restricted Boltzmann machines and suggest a novel temporal autoencoding training procedure. When tested on a dynamic multi-variate benchmark dataset this method outperformed existing models of this class. Learning features on a large dataset of natural movies allowed us to model spatio-temporal receptive fields for single neurons. They resemble temporally smooth transformations of previously obtained static receptive fields and are thus consistent with existing theories. A neuronal spike response model demonstrates how the dynamic receptive field facilitates temporal and population sparseness. We discuss the potential mechanisms and benefits of a spatially and temporally sparse representation of natural visual input. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Can Blindsight Be Superior to "Sighted-Sight"?
ERIC Educational Resources Information Center
Trevethan, Ceri T.; Sahraie, Arash; Weiskrantz, Larry
2007-01-01
DB, the first blindsight case to be tested extensively (Weiskrantz, 1986) has demonstrated the ability to detect and discriminate a range of visual stimuli presented within his perimetrically blind visual field defect. In a temporal two alternative forced choice (2AFC) detection experiment we have investigated the limits of DB's detection ability…
Learning to Verbally & Visually Communicate the Metalworking Way.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento. Div. of Vocational Education.
This curriculum guide, one of 15 volumes written for field test use with educationally disadvantaged industrial education students needing additional instruction in the basic skill areas, deals with helping students develop basic verbal and visual communication skills while studying metalworking. Addressed in the individual units of the guide are…
Artes, Paul H; Henson, David B; Harper, Robert; McLeod, David
2003-06-01
To compare a multisampling suprathreshold strategy with conventional suprathreshold and full-threshold strategies in detecting localized visual field defects and in quantifying the area of loss. Probability theory was applied to examine various suprathreshold pass criteria (i.e., the number of stimuli that have to be seen for a test location to be classified as normal). A suprathreshold strategy that requires three seen or three missed stimuli per test location (multisampling suprathreshold) was selected for further investigation. Simulation was used to determine how the multisampling suprathreshold, conventional suprathreshold, and full-threshold strategies detect localized field loss. To determine the systematic error and variability in estimates of loss area, artificial fields were generated with clustered defects (0-25 field locations with 8- and 16-dB loss) and, for each condition, the number of test locations classified as defective (suprathreshold strategies) and with pattern deviation probability less than 5% (full-threshold strategy), was derived from 1000 simulated test results. The full-threshold and multisampling suprathreshold strategies had similar sensitivity to field loss. Both detected defects earlier than the conventional suprathreshold strategy. The pattern deviation probability analyses of full-threshold results underestimated the area of field loss. The conventional suprathreshold perimetry also underestimated the defect area. With multisampling suprathreshold perimetry, the estimates of defect area were less variable and exhibited lower systematic error. Multisampling suprathreshold paradigms may be a powerful alternative to other strategies of visual field testing. Clinical trials are needed to verify these findings.
Rapid Onset of Retinal Toxicity From High-Dose Hydroxychloroquine Given for Cancer Therapy.
Leung, Loh-Shan B; Neal, Joel W; Wakelee, Heather A; Sequist, Lecia V; Marmor, Michael F
2015-10-01
To report rapid onset of retinal toxicity in a series of patients followed on high-dose (1000 mg daily) hydroxychloroquine during an oncologic clinical trial studying hydroxychloroquine with erlotinib for non-small cell lung cancer. Retrospective observational case series. Ophthalmic surveillance was performed on patients in a multicenter clinical trial testing high-dose (1000 mg daily) hydroxychloroquine for advanced non-small cell lung cancer. The US Food & Drug Administration-recommended screening protocol included only visual acuity testing, dilated fundus examination, Amsler grid testing, and color vision testing. In patients seen at Stanford, additional sensitive screening procedures were added at the discretion of the retinal physician: high-resolution spectral-domain optical coherence tomography (OCT), fundus autofluorescence (FAF) imaging, Humphrey visual field (HVF) testing, and multifocal electroretinography (mfERG). Out of the 7 patients having exposure of at least 6 months, 2 developed retinal toxicity (at 11 and 17 months of exposure). Damage was identified by OCT imaging, mfERG testing, and, in 1 case, visual field testing. Fundus autofluorescence imaging remained normal. Neither patient had symptomatic visual acuity loss. These cases show that high doses of hydroxychloroquine can initiate the development of retinal toxicity within 1-2 years. Although synergy with erlotinib is theoretically possible, there are no prior reports of erlotinib-associated retinal toxicity despite over a decade of use in oncology. These results also suggest that sensitive retinal screening tests should be added to ongoing and future clinical trials involving high-dose hydroxychloroquine to improve safety monitoring and preservation of vision. Published by Elsevier Inc.
Vertical visual features have a strong influence on cuttlefish camouflage.
Ulmer, K M; Buresch, K C; Kossodo, M M; Mäthger, L M; Siemann, L A; Hanlon, R T
2013-04-01
Cuttlefish and other cephalopods use visual cues from their surroundings to adaptively change their body pattern for camouflage. Numerous previous experiments have demonstrated the influence of two-dimensional (2D) substrates (e.g., sand and gravel habitats) on camouflage, yet many marine habitats have varied three-dimensional (3D) structures among which cuttlefish camouflage from predators, including benthic predators that view cuttlefish horizontally against such 3D backgrounds. We conducted laboratory experiments, using Sepia officinalis, to test the relative influence of horizontal versus vertical visual cues on cuttlefish camouflage: 2D patterns on benthic substrates were tested versus 2D wall patterns and 3D objects with patterns. Specifically, we investigated the influence of (i) quantity and (ii) placement of high-contrast elements on a 3D object or a 2D wall, as well as (iii) the diameter and (iv) number of 3D objects with high-contrast elements on cuttlefish body pattern expression. Additionally, we tested the influence of high-contrast visual stimuli covering the entire 2D benthic substrate versus the entire 2D wall. In all experiments, visual cues presented in the vertical plane evoked the strongest body pattern response in cuttlefish. These experiments support field observations that, in some marine habitats, cuttlefish will respond to vertically oriented background features even when the preponderance of visual information in their field of view seems to be from the 2D surrounding substrate. Such choices highlight the selective decision-making that occurs in cephalopods with their adaptive camouflage capability.
Changes in the distribution of sustained attention alter the perceived structure of visual space.
Fortenbaugh, Francesca C; Robertson, Lynn C; Esterman, Michael
2017-02-01
Visual spatial attention is a critical process that allows for the selection and enhanced processing of relevant objects and locations. While studies have shown attentional modulations of perceived location and the representation of distance information across multiple objects, there remains disagreement regarding what influence spatial attention has on the underlying structure of visual space. The present study utilized a method of magnitude estimation in which participants must judge the location of briefly presented targets within the boundaries of their individual visual fields in the absence of any other objects or boundaries. Spatial uncertainty of target locations was used to assess perceived locations across distributed and focused attention conditions without the use of external stimuli, such as visual cues. Across two experiments we tested locations along the cardinal and 45° oblique axes. We demonstrate that focusing attention within a region of space can expand the perceived size of visual space; even in cases where doing so makes performance less accurate. Moreover, the results of the present studies show that when fixation is actively maintained, focusing attention along a visual axis leads to an asymmetrical stretching of visual space that is predominantly focused across the central half of the visual field, consistent with an expansive gradient along the focus of voluntary attention. These results demonstrate that focusing sustained attention peripherally during active fixation leads to an asymmetrical expansion of visual space within the central visual field. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
Baisley, R. L.
1973-01-01
The results of an evaluation of police helicopter effectiveness revealed a need for improved visual capability. A JPL program developed a method that would enhance visual observation capability for both day and night usage and demonstrated the feasibility of the adopted approach. This approach made use of remote pointable optics, a display screen, a slaved covert searchlight, and a coupled camera. The approach was proved feasible through field testing and by judgement against evaluation criteria.
[Features associated with retinal thickness extension in diabetic macular oedema].
Razo Blanco-Hernández, Dulce Milagros; Lima-Gómez, Virgilio; García-Rubio, Yatzul Zuhaila
2015-01-01
Clinically significant macular edema has features that are associated with a major risk of visual loss, with thickening that involves the centre of the macula, field 7 or visual deficiency, although it is unknown if these features are related to retinal thickness extension. An observational, analytical, prospective, cross-sectional and open study was conducted. The sample was divided into initial visual acuity ≥0.5, central field thickness, center point thickness, field 7 and macular volume more than the reported 2 standard deviation mean value in eyes without retinopathy. The extension was determined by the number of the central field area equivalent thickening and these features were compared with by Student's t test for independent samples. A total of 199 eyes were included. In eyes with visual acuity of ≥0.5, the mean extension was 2.88±1.68 and 3.2±1.63 in area equivalent in eyes with visual acuity <0.5 (p=0.12). The mean extension in eyes with less than 2 standard deviation of central field thickness, center point thickness, field 7 and macular volume was significantly lower than in eyes with more than 2 standard deviations (1.9±0.93 vs. 4.07±1.49, 2.44±1.47 vs. 3.94±1.52, 1.79±1.07 vs. 3.61±1.57 and 1.6±0.9 vs. 3.9±1.4, respectively, p<0.001). The extension of retinal thickness is related with the anatomical features reported with a greater risk of visual loss, but is not related to initial visual deficiency. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Colored floaters as a manifestation of digoxin toxicity.
Shi, Lynn; Sun, Linus D; Odel, Jeffrey G
2018-06-01
Since its report in one patient more than 70 years ago, digitalis-induced colored muscae volitantes have not surfaced again in the literature. We report here a case of digoxin induced colored floaters. An 89-year-old man on 0.25 mg digoxin daily developed visual hallucinations and colored floaters. He had floaters in the past but now they were in various colors including yellow, green, blue and red, though predominantly in yellow. These "weirdly" shaped little particles wiggled around as if in a viscous solution and casted shadows in his vision. He also saw geometric shapes, spirals, and cross hatch patterns of various colors that moved and undulated, especially on wallpaper. Ophthalmic examination revealed reduced visual acuity, poor color vision especially in his left eye, along with central depression on Amsler grid and Humphrey visual field in his left eye. Discontinuation of digoxin resulted in complete resolution of his visual symptoms. On subsequent ophthalmic examination, the patient's visual acuity, field testing and color vision improved and he had normal Amsler grid test results. Colored floaters may occur in patients taking cardiac glycosides but this association has not been explored. Unlike optical illusions and visual hallucinations, floaters are entoptic phenomena casting a physical shadow upon the retina and their coloring likely arise from retinal dysfunction. Colored floaters may be a more common visual phenomenon than realized.
[Visual field progression in glaucoma: cluster analysis].
Bresson-Dumont, H; Hatton, J; Foucher, J; Fonteneau, M
2012-11-01
Visual field progression analysis is one of the key points in glaucoma monitoring, but distinction between true progression and random fluctuation is sometimes difficult. There are several different algorithms but no real consensus for detecting visual field progression. The trend analysis of global indices (MD, sLV) may miss localized deficits or be affected by media opacities. Conversely, point-by-point analysis makes progression difficult to differentiate from physiological variability, particularly when the sensitivity of a point is already low. The goal of our study was to analyse visual field progression with the EyeSuite™ Octopus Perimetry Clusters algorithm in patients with no significant changes in global indices or worsening of the analysis of pointwise linear regression. We analyzed the visual fields of 162 eyes (100 patients - 58 women, 42 men, average age 66.8 ± 10.91) with ocular hypertension or glaucoma. For inclusion, at least six reliable visual fields per eye were required, and the trend analysis (EyeSuite™ Perimetry) of visual field global indices (MD and SLV), could show no significant progression. The analysis of changes in cluster mode was then performed. In a second step, eyes with statistically significant worsening of at least one of their clusters were analyzed point-by-point with the Octopus Field Analysis (OFA). Fifty four eyes (33.33%) had a significant worsening in some clusters, while their global indices remained stable over time. In this group of patients, more advanced glaucoma was present than in stable group (MD 6.41 dB vs. 2.87); 64.82% (35/54) of those eyes in which the clusters progressed, however, had no statistically significant change in the trend analysis by pointwise linear regression. Most software algorithms for analyzing visual field progression are essentially trend analyses of global indices, or point-by-point linear regression. This study shows the potential role of analysis by clusters trend. However, for best results, it is preferable to compare the analyses of several tests in combination with morphologic exam. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Chang, Melinda Y.; Pineles, Stacy L.
2016-01-01
Optic disc drusen occur in 0.4% of children and consist of acellular intracellular and extracellular deposits that often become calcified over time. They are typically buried early in life and generally become superficial, and therefore visible, later in childhood, at the average age of 12 years. Their main clinical significance lies in the ability of optic disc drusen, particularly when buried, to simulate true optic disc edema. Misdiagnosing drusen as true disc edema may lead to an invasive and unnecessary workup for elevated intracranial pressure. Ancillary testing, including ultrasonography, fluorescein angiography, fundus autofluorescence, and optical coherence tomography, may aid in the correct diagnosis of optic disc drusen. Complications of optic disc drusen in children include visual field defects, hemorrhages, choroidal neovascular membrane, non-arteritic anterior ischemic optic neuropathy, and retinal vascular occlusions. Treatment options for these complications include ocular hypotensive agents for visual field defects and intravitreal anti-vascular endothelial growth factor (anti-VEGF) agents for choroidal neovascular membranes. In most cases, however, children with optic disc drusen can be managed by observation with serial examinations and visual field testing, once true optic disc edema has been excluded. PMID:27033945
Sadeh, Morteza; Sajad, Amirsaman; Wang, Hongying; Yan, Xiaogang; Crawford, John Douglas
2015-12-01
We previously reported that visuomotor activity in the superior colliculus (SC)--a key midbrain structure for the generation of rapid eye movements--preferentially encodes target position relative to the eye (Te) during low-latency head-unrestrained gaze shifts (DeSouza et al., 2011). Here, we trained two monkeys to perform head-unrestrained gaze shifts after a variable post-stimulus delay (400-700 ms), to test whether temporally separated SC visual and motor responses show different spatial codes. Target positions, final gaze positions and various frames of reference (eye, head, and space) were dissociated through natural (untrained) trial-to-trial variations in behaviour. 3D eye and head orientations were recorded, and 2D response field data were fitted against multiple models by use of a statistical method reported previously (Keith et al., 2009). Of 60 neurons, 17 showed a visual response, 12 showed a motor response, and 31 showed both visual and motor responses. The combined visual response field population (n = 48) showed a significant preference for Te, which was also preferred in each visual subpopulation. In contrast, the motor response field population (n = 43) showed a preference for final (relative to initial) gaze position models, and the Te model was statistically eliminated in the motor-only population. There was also a significant shift of coding from the visual to motor response within visuomotor neurons. These data confirm that SC response fields are gaze-centred, and show a target-to-gaze transformation between visual and motor responses. Thus, visuomotor transformations can occur between, and even within, neurons within a single frame of reference and brain structure. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Okada, Takashi; Sato, Wataru; Kubota, Yasutaka; Toichi, Motomi; Murai, Toshiya
2012-03-01
The neural substrate for the processing of gaze remains unknown. The aim of the present study was to clarify which hemisphere dominantly processes and whether bilateral hemispheres cooperate with each other in gaze-triggered reflexive shift of attention. Twenty-eight normal subjects were tested. The non-predictive gaze cues were presented either in unilateral or bilateral visual fields. The subjects localized the target as soon as possible. Reaction times (RT) were shorter when gaze-cues were congruent toward than away from targets, whichever visual field they were presented in. RT were shorter in left than right visual field presentations. RT in mono-directional bilateral presentations were shorter than both of those in left and right presentations. When bi-directional bilateral cues were presented, RT were faster when valid cues were presented in the left than right visual fields. The right hemisphere appears to be dominant, and there is interhemispheric cooperation in gaze-triggered reflexive shift of attention. © 2012 The Authors. Psychiatry and Clinical Neurosciences © 2012 Japanese Society of Psychiatry and Neurology.
Aircrew laser eye protection: visual consequences and mission performance.
Thomas, S R
1994-05-01
Battlefield laser proliferation poses a mounting risk to aircrew and ground personnel. Laser eye protection (LEP) based on current mature, mass-producible technologies absorbs visible light and can impact visual performance and color identification. These visual consequences account for many of the mission incompatibilities associated with LEP. Laboratory experiments and field investigations that examined the effects of LEP on visual performance and mission compatibility are reviewed. Laboratory experiments assessed the ability of subjects to correctly read and identify the color of head-down display symbology and tactical pilotage charts (TPC's) with three prototype LEP visors. Field investigations included Weapons Systems Trainer (WST), ground, and flight tests of the LEP visors. Recommendations for modifying aviation lighting systems to improve LEP compatibility are proposed. Issues concerning flight safety when using LEP during air operation are discussed.
Peripheral defocus does not necessarily affect central refractive development.
Schippert, Ruth; Schaeffel, Frank
2006-10-01
Recent experiments in monkeys suggest that deprivation, imposed only in the periphery of the visual field, can induce foveal myopia. This raises the hypothesis that peripheral refractive errors imposed by the spectacle lens correction could influence foveal refractive development also in humans. We have tested this hypothesis in chicks. Chicks wore either full field spectacle lenses (+6.9 D/-7 D), or lenses with central holes of 4, 6, or 8mm diameter, for 4 days (n=6 for each group). Refractions were measured in the central visual field, and at -45 degrees (temporal) and +45 degrees (nasal), and axial lengths were measured by A-scan ultrasonography. As previously described, full field lenses were largely compensated within 4 days (refraction changes with positive lenses: +4.69+/-1.73 D, negative lenses: -5.98+/-1.78 D, both p<0.001, Dunnett's test, to untreated controls). With holes in the center of the lenses, the central refraction remained emmetropic and there was not even a trend of a shift in refraction (all groups: p>0.5, Dunnetts test). At +/-45 degrees , the lenses were partially compensated despite the 4/6/8mm central holes; positive lenses: +2.63 / +1.44 / +0.43 D, negative lenses: -2.57 / -1.06 / +0.06 D. There is extensive local compensation of imposed refractive errors in chickens. For the tested hole sizes, peripherally imposed defocus did not influence central refractive development. To alter central refractive development, the unobstructed part in the central visual field may have to be quite small (hole sizes smaller than 4mm, with the lenses at a vertex distance of 2-3mm).
NASA Astrophysics Data System (ADS)
Houser, P. I. Q.
2017-12-01
21st century earth science is data-intensive, characterized by heterogeneous, sometimes voluminous collections representing phenomena at different scales collected for different purposes and managed in disparate ways. However, much of the earth's surface still requires boots-on-the-ground, in-person fieldwork in order to detect the subtle variations from which humans can infer complex structures and patterns. Nevertheless, field experiences can and should be enabled and enhanced by a variety of emerging technologies. The goal of the proposed research project is to pilot test emerging data integration, semantic and visualization technologies for evaluation of their potential usefulness in the field sciences, particularly in the context of field geology. The proposed project will investigate new techniques for data management and integration enabled by semantic web technologies, along with new techniques for augmented reality that can operate on such integrated data to enable in situ visualization in the field. The research objectives include: Develop new technical infrastructure that applies target technologies to field geology; Test, evaluate, and assess the technical infrastructure in a pilot field site; Evaluate the capabilities of the systems for supporting and augmenting field science; and Assess the generality of the system for implementation in new and different types of field sites. Our hypothesis is that these technologies will enable what we call "field science situational awareness" - a cognitive state formerly attained only through long experience in the field - that is highly desirable but difficult to achieve in time- and resource-limited settings. Expected outcomes include elucidation of how, and in what ways, these technologies are beneficial in the field; enumeration of the steps and requirements to implement these systems; and cost/benefit analyses that evaluate under what conditions the investments of time and resources are advisable to construct such system.
Looking above the prairie: localized and upward acute vision in a native grassland bird.
Tyrrell, Luke P; Moore, Bret A; Loftis, Christopher; Fernández-Juricic, Esteban
2013-12-02
Visual systems of open habitat vertebrates are predicted to have a band of acute vision across the retina (visual streak) and wide visual coverage to gather information along the horizon. We tested whether the eastern meadowlark (Sturnella magna) had this visual configuration given that it inhabits open grasslands. Contrary to our expectations, the meadowlark retina has a localized spot of acute vision (fovea) and relatively narrow visual coverage. The fovea projects above rather than towards the horizon with the head at rest, and individuals modify their body posture in tall grass to maintain a similar foveal projection. Meadowlarks have relatively large binocular fields and can see their bill tips, which may help with their probe-foraging technique. Overall, meadowlark vision does not fit the profile of vertebrates living in open habitats. The binocular field may control foraging while the fovea may be used for detecting and tracking aerial stimuli (predators, conspecifics).
Vision in two cyprinid fish: implications for collective behavior
Moore, Bret A.; Tyrrell, Luke P.; Fernández-Juricic, Esteban
2015-01-01
Many species of fish rely on their visual systems to interact with conspecifics and these interactions can lead to collective behavior. Individual-based models have been used to predict collective interactions; however, these models generally make simplistic assumptions about the sensory systems that are applied without proper empirical testing to different species. This could limit our ability to predict (and test empirically) collective behavior in species with very different sensory requirements. In this study, we characterized components of the visual system in two species of cyprinid fish known to engage in visually dependent collective interactions (zebrafish Danio rerio and golden shiner Notemigonus crysoleucas) and derived quantitative predictions about the positioning of individuals within schools. We found that both species had relatively narrow binocular and blind fields and wide visual coverage. However, golden shiners had more visual coverage in the vertical plane (binocular field extending behind the head) and higher visual acuity than zebrafish. The centers of acute vision (areae) of both species projected in the fronto-dorsal region of the visual field, but those of the zebrafish projected more dorsally than those of the golden shiner. Based on this visual sensory information, we predicted that: (a) predator detection time could be increased by >1,000% in zebrafish and >100% in golden shiners with an increase in nearest neighbor distance, (b) zebrafish schools would have a higher roughness value (surface area/volume ratio) than those of golden shiners, (c) and that nearest neighbor distance would vary from 8 to 20 cm to visually resolve conspecific striping patterns in both species. Overall, considering between-species differences in the sensory system of species exhibiting collective behavior could change the predictions about the positioning of individuals in the group as well as the shape of the school, which can have implications for group cohesion. We suggest that more effort should be invested in assessing the role of the sensory system in shaping local interactions driving collective behavior. PMID:26290783
Holló, Gábor
2017-07-01
To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.
Age-related changes in visual exploratory behavior in a natural scene setting
Hamel, Johanna; De Beukelaer, Sophie; Kraft, Antje; Ohl, Sven; Audebert, Heinrich J.; Brandt, Stephan A.
2013-01-01
Diverse cognitive functions decline with increasing age, including the ability to process central and peripheral visual information in a laboratory testing situation (useful visual field of view). To investigate whether and how this influences activities of daily life, we studied age-related changes in visual exploratory behavior in a natural scene setting: a driving simulator paradigm of variable complexity was tested in subjects of varying ages with simultaneous eye- and head-movement recordings via a head-mounted camera. Detection and reaction times were also measured by visual fixation and manual reaction. We considered video computer game experience as a possible influence on performance. Data of 73 participants of varying ages were analyzed, driving two different courses. We analyzed the influence of route difficulty level, age, and eccentricity of test stimuli on oculomotor and driving behavior parameters. No significant age effects were found regarding saccadic parameters. In the older subjects head-movements increasingly contributed to gaze amplitude. More demanding courses and more peripheral stimuli locations induced longer reaction times in all age groups. Deterioration of the functionally useful visual field of view with increasing age was not suggested in our study group. However, video game-experienced subjects revealed larger saccade amplitudes and a broader distribution of fixations on the screen. They reacted faster to peripheral objects suggesting the notion of a general detection task rather than perceiving driving as a central task. As the video game-experienced population consisted of younger subjects, our study indicates that effects due to video game experience can easily be misinterpreted as age effects if not accounted for. We therefore view it as essential to consider video game experience in all testing methods using virtual media. PMID:23801970
Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.
Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat
2016-10-01
To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.
Chauhan, Balwantray C; Keltner, John L; Cello, Kim E; Johnson, Chris A; Anderson, Douglas R; Gordon, Mae O; Kass, Michael A
2014-01-01
Purpose Visual field progression can be determined by evaluating the visual field by serial examinations (longitudinal analysis), or by a change in classification derived from comparison to age-matched normal data in single examinations (cross-sectional analysis). We determined the agreement between these two approaches in data from the Ocular Hypertension Treatment Study (OHTS). Methods Visual field data from 3088 eyes of 1570 OHTS participants (median follow-up 7 yrs, 15 tests with static automated perimetry) were analysed. Longitudinal analyses were performed with change probability with total and pattern deviation, and cross-sectional analysis with Glaucoma Hemifield Test, Corrected Pattern Standard Deviation, and Mean Deviation. The rates of Mean Deviation and General Height change were compared to estimate the degree of diffuse loss in emerging glaucoma. Results The agreement on progression in longitudinal and cross-sectional analyses ranged from 50% to 61% and remained nearly constant across a wide range of criteria. In contrast, the agreement on absence of progression ranged from 97% to 99.7%, being highest for the stricter criteria. Analyses of pattern deviation were more conservative than total deviation, with a 3 to 5 times lesser incidence of progression. Most participants developing field loss had both diffuse and focal change. Conclusions Despite considerable overall agreement, between 40 to 50% of eyes identified as having progressed with either longitudinal or cross-sectional analyses were identified with only one of the analyses. Because diffuse change is part of early glaucomatous damage, pattern deviation analyses may underestimate progression in patients with ocular hypertension. PMID:21149774
Measurement of electromagnetic tracking error in a navigated breast surgery setup
NASA Astrophysics Data System (ADS)
Harish, Vinyas; Baksh, Aidan; Ungi, Tamas; Lasso, Andras; Baum, Zachary; Gauvin, Gabrielle; Engel, Jay; Rudan, John; Fichtinger, Gabor
2016-03-01
PURPOSE: The measurement of tracking error is crucial to ensure the safety and feasibility of electromagnetically tracked, image-guided procedures. Measurement should occur in a clinical environment because electromagnetic field distortion depends on positioning relative to the field generator and metal objects. However, we could not find an accessible and open-source system for calibration, error measurement, and visualization. We developed such a system and tested it in a navigated breast surgery setup. METHODS: A pointer tool was designed for concurrent electromagnetic and optical tracking. Software modules were developed for automatic calibration of the measurement system, real-time error visualization, and analysis. The system was taken to an operating room to test for field distortion in a navigated breast surgery setup. Positional and rotational electromagnetic tracking errors were then calculated using optical tracking as a ground truth. RESULTS: Our system is quick to set up and can be rapidly deployed. The process from calibration to visualization also only takes a few minutes. Field distortion was measured in the presence of various surgical equipment. Positional and rotational error in a clean field was approximately 0.90 mm and 0.31°. The presence of a surgical table, an electrosurgical cautery, and anesthesia machine increased the error by up to a few tenths of a millimeter and tenth of a degree. CONCLUSION: In a navigated breast surgery setup, measurement and visualization of tracking error defines a safe working area in the presence of surgical equipment. Our system is available as an extension for the open-source 3D Slicer platform.
Modified visual field trend analysis.
De Moraes, Carlos Gustavo V; Ritch, Robert; Tello, Celso; Liebmann, Jeffrey M
2011-01-01
Visual field trend analysis can be influenced by outlying values that may disproportionately affect estimation of the rate of change. We tested a modified approach to visual field trend analysis to minimize this problem. Automated pointwise linear regression (PLR) was used in glaucoma patients with ≥13 SITA-Standard 24-2 VF tests in either eye. In the control group (Group A), conventional PLR using the entire set of VF tests was carried out. In the other 3 groups (study groups), a truncated analysis was done using only the first and last 3 (Group B), first and last 4 (Group C), or first and last 5 (Group D) VF tests. We compared the global slopes (dB/y), number of eyes experiencing significant progression, and significant improvement between groups. Ninety eyes of 90 patients were evaluated. The mean number±SD of VF tests was 15.7±2.6, spanning 7.8±1.7 years. The study groups showed similar global rates of VF change as the control group (Group A=-0.48±0.5, Group B=-0.48±0.6, Group C=-0.48±0.6, Group D=-0.48±0.5 dB/y, P>0.05), and a similar number of eyes reaching a progression endpoint (Group A=53, Group B=52, Group C=49, Group D=53, P>0.05). However, Group B showed fewer eyes presenting VF improvement (false-positives). The modified VF trend-analysis showed greater specificity than conventional PLR in a population with glaucoma.
Visual abilities in two raptors with different ecology.
Potier, Simon; Bonadonna, Francesco; Kelber, Almut; Martin, Graham R; Isard, Pierre-François; Dulaurent, Thomas; Duriez, Olivier
2016-09-01
Differences in visual capabilities are known to reflect differences in foraging behaviour even among closely related species. Among birds, the foraging of diurnal raptors is assumed to be guided mainly by vision but their foraging tactics include both scavenging upon immobile prey and the aerial pursuit of highly mobile prey. We studied how visual capabilities differ between two diurnal raptor species of similar size: Harris's hawks, Parabuteo unicinctus, which take mobile prey, and black kites, Milvus migrans, which are primarily carrion eaters. We measured visual acuity, foveal characteristics and visual fields in both species. Visual acuity was determined using a behavioural training technique; foveal characteristics were determined using ultra-high resolution spectral-domain optical coherence tomography (OCT); and visual field parameters were determined using an ophthalmoscopic reflex technique. We found that these two raptors differ in their visual capacities. Harris's hawks have a visual acuity slightly higher than that of black kites. Among the five Harris's hawks tested, individuals with higher estimated visual acuity made more horizontal head movements before making a decision. This may reflect an increase in the use of monocular vision. Harris's hawks have two foveas (one central and one temporal), while black kites have only one central fovea and a temporal area. Black kites have a wider visual field than Harris's hawks. This may facilitate the detection of conspecifics when they are scavenging. These differences in the visual capabilities of these two raptors may reflect differences in the perceptual demands of their foraging behaviours. © 2016. Published by The Company of Biologists Ltd.
ERIC Educational Resources Information Center
Simmering, Vanessa R.; Patterson, Rebecca
2012-01-01
Numerous studies have established that visual working memory has a limited capacity that increases during childhood. However, debate continues over the source of capacity limits and its developmental increase. Simmering (2008) adapted a computational model of spatial cognitive development, the Dynamic Field Theory, to explain not only the source…
Adding Test Generation to the Teaching Machine
ERIC Educational Resources Information Center
Bruce-Lockhart, Michael; Norvell, Theodore; Crescenzi, Pierluigi
2009-01-01
We propose an extension of the Teaching Machine project, called Quiz Generator, that allows instructors to produce assessment quizzes in the field of algorithm and data structures quite easily. This extension makes use of visualization techniques and is based on new features of the Teaching Machine that allow third-party visualizers to be added as…
Real-Time Aerodynamic Flow and Data Visualization in an Interactive Virtual Environment
NASA Technical Reports Server (NTRS)
Schwartz, Richard J.; Fleming, Gary A.
2005-01-01
Significant advances have been made to non-intrusive flow field diagnostics in the past decade. Camera based techniques are now capable of determining physical qualities such as surface deformation, surface pressure and temperature, flow velocities, and molecular species concentration. In each case, extracting the pertinent information from the large volume of acquired data requires powerful and efficient data visualization tools. The additional requirement for real time visualization is fueled by an increased emphasis on minimizing test time in expensive facilities. This paper will address a capability titled LiveView3D, which is the first step in the development phase of an in depth, real time data visualization and analysis tool for use in aerospace testing facilities.
Latency in Visionic Systems: Test Methods and Requirements
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.
2005-01-01
A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.
[Acute visual loss in pregnancy caused by craniopharyngioma].
Grillo-Mallo, E; Jiménez-Benito, J; Diéz-Feijóo, E; Alonso Alonso, I; Ferrero Collado, A; Muñoz Quiñones, S
2014-04-01
A 38-year-old female, at 20-weeks gestation, experienced a sudden visual loss and visual-field abnormalities. The neuroimaging tests showed a craniopharyngioma. Surgical removal was performed with a successful outcome as regards the pregnancy and visual function. It is known that pituitary adenomas may grow during pregnancy; however this is unusual in craniopharyngiomas. They usually present with visual problems due to their suprasellar topography. Surgery is the treatment of choice, the outcome essentially depending on its complete resection. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Short-term memory for spatial configurations in the tactile modality: a comparison with vision.
Picard, Delphine; Monnier, Catherine
2009-11-01
This study investigates the role of acquisition constraints on the short-term retention of spatial configurations in the tactile modality in comparison with vision. It tests whether the sequential processing of information inherent to the tactile modality could account for limitation in short-term memory span for tactual-spatial information. In addition, this study investigates developmental aspects of short-term memory for tactual- and visual-spatial configurations. A total of 144 child and adult participants were assessed for their memory span in three different conditions: tactual, visual, and visual with a limited field of view. The results showed lower tactual-spatial memory span than visual-spatial, regardless of age. However, differences in memory span observed between the tactile and visual modalities vanished when the visual processing of information occurred within a limited field. These results provide evidence for an impact of acquisition constraints on the retention of spatial information in the tactile modality in both childhood and adulthood.
A linear model fails to predict orientation selectivity of cells in the cat visual cortex.
Volgushev, M; Vidyasagar, T R; Pei, X
1996-01-01
1. Postsynaptic potentials (PSPs) evoked by visual stimulation in simple cells in the cat visual cortex were recorded using in vivo whole-cell technique. Responses to small spots of light presented at different positions over the receptive field and responses to elongated bars of different orientations centred on the receptive field were recorded. 2. To test whether a linear model can account for orientation selectivity of cortical neurones, responses to elongated bars were compared with responses predicted by a linear model from the receptive field map obtained from flashing spots. 3. The linear model faithfully predicted the preferred orientation, but not the degree of orientation selectivity or the sharpness of orientation tuning. The ratio of optimal to non-optimal responses was always underestimated by the model. 4. Thus non-linear mechanisms, which can include suppression of non-optimal responses and/or amplification of optimal responses, are involved in the generation of orientation selectivity in the primary visual cortex. PMID:8930828
Yu, Deyue; Cheung, Sing-Hang; Legge, Gordon E; Chung, Susana T L
2010-04-21
Enhancing reading ability in peripheral vision is important for the rehabilitation of people with central-visual-field loss from age-related macular degeneration (AMD). Previous research has shown that perceptual learning, based on a trigram letter-recognition task, improved peripheral reading speed among normally-sighted young adults (Chung, Legge, & Cheung, 2004). Here we ask whether the same happens in older adults in an age range more typical of the onset of AMD. Eighteen normally-sighted subjects, aged 55-76years, were randomly assigned to training or control groups. Visual-span profiles (plots of letter-recognition accuracy as a function of horizontal letter position) and RSVP reading speeds were measured at 10 degrees above and below fixation during pre- and post-tests for all subjects. Training consisted of repeated measurements of visual-span profiles at 10 degrees below fixation, in four daily sessions. The control subjects did not receive any training. Perceptual learning enlarged the visual spans in both trained (lower) and untrained (upper) visual fields. Reading speed improved in the trained field by 60% when the trained print size was used. The training benefits for these older subjects were weaker than the training benefits for young adults found by Chung et al. Despite the weaker training benefits, perceptual learning remains a potential option for low-vision reading rehabilitation among older adults. Copyright 2010 Elsevier Ltd. All rights reserved.
Flow Visualization Techniques in Wind Tunnel Tests of a Full-Scale F/A-18 Aircraft
NASA Technical Reports Server (NTRS)
Lanser, Wendy R.; Botha, Gavin J.; James, Kevin D.; Bennett, Mark; Crowder, James P.; Cooper, Don; Olson, Lawrence (Technical Monitor)
1994-01-01
The proposed paper presents flow visualization performed during experiments conducted on a full-scale F/A-18 aircraft in the 80- by 120-Foot Wind-Tunnel at NASA Ames Research Center. The purpose of the flow-visualization experiments was to document the forebody and leading edge extension (LEX) vortex interaction along with the wing flow patterns at high angles of attack and low speed high Reynolds number conditions. This investigation used surface pressures in addition to both surface and off-surface flow visualization techniques to examine the flow field on the forebody, canopy, LEXS, and wings. The various techniques used to visualize the flow field were fluorescent tufts, flow cones treated with reflective material, smoke in combination with a laser light sheet, and a video imaging system for three-dimension vortex tracking. The flow visualization experiments were conducted over an angle of attack range from 20 deg to 45 deg and over a sideslip range from -10 deg to 10 deg. The various visualization techniques as well as the pressure distributions were used to understand the flow field structure. The results show regions of attached and separated flow on the forebody, canopy, and wings as well as the vortical flow over the leading-edge extensions. This paper will also present flow visualization comparisons with the F-18 HARV flight vehicle and small-scale oil flows on the F-18.
Effects of kinesthetic and cutaneous stimulation during the learning of a viscous force field.
Rosati, Giulio; Oscari, Fabio; Pacchierotti, Claudio; Prattichizzo, Domenico
2014-01-01
Haptic stimulation can help humans learn perceptual motor skills, but the precise way in which it influences the learning process has not yet been clarified. This study investigates the role of the kinesthetic and cutaneous components of haptic feedback during the learning of a viscous curl field, taking also into account the influence of visual feedback. We present the results of an experiment in which 17 subjects were asked to make reaching movements while grasping a joystick and wearing a pair of cutaneous devices. Each device was able to provide cutaneous contact forces through a moving platform. The subjects received visual feedback about joystick's position. During the experiment, the system delivered a perturbation through (1) full haptic stimulation, (2) kinesthetic stimulation alone, (3) cutaneous stimulation alone, (4) altered visual feedback, or (5) altered visual feedback plus cutaneous stimulation. Conditions 1, 2, and 3 were also tested with the cancellation of the visual feedback of position error. Results indicate that kinesthetic stimuli played a primary role during motor adaptation to the viscous field, which is a fundamental premise to motor learning and rehabilitation. On the other hand, cutaneous stimulation alone appeared not to bring significant direct or adaptation effects, although it helped in reducing direct effects when used in addition to kinesthetic stimulation. The experimental conditions with visual cancellation of position error showed slower adaptation rates, indicating that visual feedback actively contributes to the formation of internal models. However, modest learning effects were detected when the visual information was used to render the viscous field.
Benefits of interhemispheric integration on the Japanese Kana script-matching tasks.
Yoshizaki, K; Tsuji, Y
2000-02-01
We tested Banich's hypothesis that the benefits of bihemispheric processing were enhanced as task complexity increased, when some procedural shortcomings in the previous studies were overcome by using Japanese Kana script-matching tasks. In Exp. 1, the 20 right-handed subjects were given the Physical-Identity task (Katakana-Katakana scripts matching) and the Name-Identity task (Katakana-Hiragana scripts matching). On both tasks, a pair of Kana scripts was tachistoscopically presented in the left, right, and bilateral visual fields. Distractor stimuli were also presented with target Kana scripts on both tasks to equate the processing load between the hemispheres. Analysis showed that, while a bilateral visual-field advantage was found on the name-identity task, a unilateral visual-field advantage was found on the physical-identity task, suggesting that, as the computational complexity of the encoding stage was enhanced, the benefits of bilateral hemispheric processing increased. In Exp. 2, the 16 right-handed subjects were given the same physical-identity task as in Exp. 1, except Hiragana scripts were used as distractors instead of digits to enhance task difficulty. Analysis showed no differences in performance between the unilateral and bilateral visual fields. Taking into account these results of physical-identity tasks for both Exps. 1 and 2, enhancing task demand in the stage of ignoring distractors made the unilateral visual-field advantage obtained in Exp. 1 disappear in Exp. 2. These results supported Banich's hypothesis.
Adhikarla, Vamsi Kiran; Sodnik, Jaka; Szolgay, Peter; Jakus, Grega
2015-01-01
This paper reports on the design and evaluation of direct 3D gesture interaction with a full horizontal parallax light field display. A light field display defines a visual scene using directional light beams emitted from multiple light sources as if they are emitted from scene points. Each scene point is rendered individually resulting in more realistic and accurate 3D visualization compared to other 3D displaying technologies. We propose an interaction setup combining the visualization of objects within the Field Of View (FOV) of a light field display and their selection through freehand gesture tracked by the Leap Motion Controller. The accuracy and usefulness of the proposed interaction setup was also evaluated in a user study with test subjects. The results of the study revealed high user preference for free hand interaction with light field display as well as relatively low cognitive demand of this technique. Further, our results also revealed some limitations and adjustments of the proposed setup to be addressed in future work. PMID:25875189
High-Speed PLIF Imaging of Hypersonic Transition over Discrete Cylindrical Roughness
NASA Technical Reports Server (NTRS)
Danehy, P. M.; Ivey, C. B.; Inman, J. A.; Bathel, B. F.; Jones, S. B.; McCrea, A. C.; Jiang, N.; Webster, M.; Lempert, W.; Miller, J.;
2010-01-01
In two separate test entries, advanced laser-based instrumentation has been developed and applied to visualize the hypersonic flow over cylindrical protrusions on a flat plate. Upstream of these trips, trace quantities of nitric oxide (NO) were seeded into the boundary layer. The protuberances were sized to force laminar-to-turbulent boundary layer transition. In the first test, a 10-Hz nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization system was used to provide wide-field-of-view, high-resolution images of the flowfield. The images had sub-microsecond time resolution. However these images, obtained with a time separation of 0.1 sec, were uncorrelated with each other. Fluorescent oil-flow visualizations were also obtained during this test. In the second experiment, a laser and camera system capable of acquiring NO PLIF measurements at 1 million frames per second (1 MHz) was used. This system had lower spatial resolution, and a smaller field of view, but the images were time correlated so that the development of the flow structures could be observed in time.
NASA Technical Reports Server (NTRS)
Hom, Kam W.
1994-01-01
In this video, several examples of electromagnetic field and surface-current animation sequences are shown to demonstrate the visualization capabilities of the EM-ANIMATE computer program. These examples show the animation of total and scattered electric near fields from test bodies of a flat plate, a corner reflector, and a sphere. These test cases show the electric-field behavior caused by different scattering mechanisms through the animation of electromagnetic data from the EM-ANIMATE routine.
LaRoche, Ronee B; Morgan, Russell E
2007-01-01
Over the past two decades the use of selective serotonin reuptake inhibitors (SSRIs) to treat behavioral disorders in children has grown rapidly, despite little evidence regarding the safety and efficacy of these drugs for use in children. Utilizing a rat model, this study investigated whether post-weaning exposure to a prototype SSRI, fluoxetine (FLX), influenced performance on visual tasks designed to measure discrimination learning, sustained attention, inhibitory control, and reaction time. Additionally, sex differences in response to varying doses of fluoxetine were examined. In Experiment 1, female rats were administered (P.O.) fluoxetine (10 mg/kg ) or vehicle (apple juice) from PND 25 thru PND 49. After a 14 day washout period, subjects were trained to perform a simultaneous visual discrimination task. Subjects were then tested for 20 sessions on a visual attention task that consisted of varied stimulus delays (0, 3, 6, or 9 s) and cue durations (200, 400, or 700 ms). In Experiment 2, both male and female Long-Evans rats (24 F, 24 M) were administered fluoxetine (0, 5, 10, or 15 mg/kg) then tested in the same visual tasks used in Experiment 1, with the addition of open-field and elevated plus-maze testing. Few FLX-related differences were seen in the visual discrimination, open field, or plus-maze tasks. However, results from the visual attention task indicated a dose-dependent reduction in the performance of fluoxetine-treated males, whereas fluoxetine-treated females tended to improve over baseline. These findings indicate that enduring, behaviorally-relevant alterations of the CNS can occur following pharmacological manipulation of the serotonin system during postnatal development.
Douglass, John K; Wehling, Martin F
2016-12-01
A highly automated goniometer instrument (called FACETS) has been developed to facilitate rapid mapping of compound eye parameters for investigating regional visual field specializations. The instrument demonstrates the feasibility of analyzing the complete field of view of an insect eye in a fraction of the time required if using non-motorized, non-computerized methods. Faster eye mapping makes it practical for the first time to employ sample sizes appropriate for testing hypotheses about the visual significance of interspecific differences in regional specializations. Example maps of facet sizes are presented from four dipteran insects representing the Asilidae, Calliphoridae, and Stratiomyidae. These maps provide the first quantitative documentation of the frontal enlarged-facet zones (EFZs) that typify asilid eyes, which, together with the EFZs in male Calliphoridae, are likely to be correlated with high-spatial-resolution acute zones. The presence of EFZs contrasts sharply with the almost homogeneous distribution of facet sizes in the stratiomyid. Moreover, the shapes of EFZs differ among species, suggesting functional specializations that may reflect differences in visual ecology. Surveys of this nature can help identify species that should be targeted for additional studies, which will elucidate fundamental principles and constraints that govern visual field specializations and their evolution.
Aptel, Florent; Sayous, Romain; Fortoul, Vincent; Beccat, Sylvain; Denis, Philippe
2010-12-01
To evaluate and compare the regional relationships between visual field sensitivity and retinal nerve fiber layer (RNFL) thickness as measured by spectral-domain optical coherence tomography (OCT) and scanning laser polarimetry. Prospective cross-sectional study. One hundred and twenty eyes of 120 patients (40 with healthy eyes, 40 with suspected glaucoma, and 40 with glaucoma) were tested on Cirrus-OCT, GDx VCC, and standard automated perimetry. Raw data on RNFL thickness were extracted for 256 peripapillary sectors of 1.40625 degrees each for the OCT measurement ellipse and 64 peripapillary sectors of 5.625 degrees each for the GDx VCC measurement ellipse. Correlations between peripapillary RNFL thickness in 6 sectors and visual field sensitivity in the 6 corresponding areas were evaluated using linear and logarithmic regression analysis. Receiver operating curve areas were calculated for each instrument. With spectral-domain OCT, the correlations (r(2)) between RNFL thickness and visual field sensitivity ranged from 0.082 (nasal RNFL and corresponding visual field area, linear regression) to 0.726 (supratemporal RNFL and corresponding visual field area, logarithmic regression). By comparison, with GDx-VCC, the correlations ranged from 0.062 (temporal RNFL and corresponding visual field area, linear regression) to 0.362 (supratemporal RNFL and corresponding visual field area, logarithmic regression). In pairwise comparisons, these structure-function correlations were generally stronger with spectral-domain OCT than with GDx VCC and with logarithmic regression than with linear regression. The largest areas under the receiver operating curve were seen for OCT superior thickness (0.963 ± 0.022; P < .001) in eyes with glaucoma and for OCT average thickness (0.888 ± 0.072; P < .001) in eyes with suspected glaucoma. The structure-function relationship was significantly stronger with spectral-domain OCT than with scanning laser polarimetry, and was better expressed logarithmically than linearly. Measurements with these 2 instruments should not be considered to be interchangeable. Copyright © 2010 Elsevier Inc. All rights reserved.
Yamin, Stephanie; Stinchcombe, Arne; Gagnon, Sylvain
2016-06-01
This study sought to predict driving performance of drivers with Alzheimer's disease (AD) using measures of attention, visual processing, and global cognition. Simulated driving performance of individuals with mild AD (n = 20) was contrasted with performance of a group of healthy controls (n = 21). Performance on measures of global cognitive function and specific tests of attention and visual processing were examined in relation to simulated driving performance. Strong associations were observed between measures of attention, notably the Test of Everyday Attention (sustained attention; r = -.651, P = .002) and the Useful Field of View (r = .563, P = .010), and driving performance among drivers with mild AD. The Visual Object and Space Perception Test-object was significantly correlated with the occurrence of crashes (r = .652, P = .002). Tests of global cognition did not correlate with simulated driving outcomes. The results suggest that professionals exercise caution when extrapolating driving performance based on global cognitive indicators. © The Author(s) 2015.
A new system for quantitative evaluation of infant gaze capabilities in a wide visual field.
Pratesi, Andrea; Cecchi, Francesca; Beani, Elena; Sgandurra, Giuseppina; Cioni, Giovanni; Laschi, Cecilia; Dario, Paolo
2015-09-07
The visual assessment of infants poses specific challenges: many techniques that are used on adults are based on the patient's response, and are not suitable for infants. Significant advances in the eye-tracking have made this assessment of infant visual capabilities easier, however, eye-tracking still requires the subject's collaboration, in most cases and thus limiting the application in infant research. Moreover, there is a lack of transferability to clinical practice, and thus it emerges the need for a new tool to measure the paradigms and explore the most common visual competences in a wide visual field. This work presents the design, development and preliminary testing of a new system for measuring infant's gaze in the wide visual field called CareToy C: CareToy for Clinics. The system is based on a commercial eye tracker (SmartEye) with six cameras running at 60 Hz, suitable for measuring an infant's gaze. In order to stimulate the infant visually and audibly, a mechanical structure has been designed to support five speakers and five screens at a specific distance (60 cm) and angle: one in the centre, two on the right-hand side and two on the left (at 30° and 60° respectively). Different tasks have been designed in order to evaluate the system capability to assess the infant's gaze movements during different conditions (such as gap, overlap or audio-visual paradigms). Nine healthy infants aged 4-10 months were assessed as they performed the visual tasks at random. We developed a system able to measure infant's gaze in a wide visual field covering a total visual range of ±60° from the centre with an intermediate evaluation at ±30°. Moreover, the same system, thanks to different integrated software, was able to provide different visual paradigms (as gap, overlap and audio-visual) assessing and comparing different visual and multisensory sub-competencies. The proposed system endowed the integration of a commercial eye-tracker into a purposive setup in a smart and innovative way. The proposed system is suitable for measuring and evaluating infant's gaze capabilities in a wide visual field, in order to provide quantitative data that can enrich the clinical assessment.
Pineda-Ortíz, Mirna; Pacheco-López, Gustavo; Rubio-Osornio, Moisés; Rubio, Carmen; Valadez-Rodríguez, Juan
2018-01-01
Abstract Rationale: Visual therapy, which includes a restorative and compensatory approach, seems to be a viable treatment option for homonymous defects of the visual field in patients with postgeniculate injury of the visual pathway, due to occipital arteriovenous malformation (AVM). Until now, the Mexican population suffering from homonymous hemianopia did not have health services that provided any type of visual therapy for their condition. Patient concerns: A 31-year-old patient, who underwent a surgical procedure for resection of the AVM, was referred with posterior low vision on the left side. Diagnoses: The patient was diagnosed with left homonymous hemianopia. Interventions: Visual neurorehabilitation therapy (NRT), which integrated restorative and compensatory approaches, was administered for 3 hours each week. NRT included fixation, follow-up, search, peripheral vision, and reading. Outcomes: The NRT did not change visual field defects and, retinotopocally, the same campimetric defects remained. However, after training the tracking ocular movements improved to standard values on the ENG, further, the visual search became more organized. The reading reached a level without mistakes, with rhythm and goog intonation. The Beck test demostrated an improvement in depression symptoms. Regarding the daily life activities, the patient reported significant improvements. Lessons: Visual NRT can significantly improve eye movements, as well as the quality of life and independence of the patient. This integral approach could be an effective therapeutic option for homonymous defects of the visual field. PMID:29538218
Lack of oblique astigmatism in the chicken eye.
Maier, Felix M; Howland, Howard C; Ohlendorf, Arne; Wahl, Siegfried; Schaeffel, Frank
2015-04-01
Primate eyes display considerable oblique off-axis astigmatism which could provide information on the sign of defocus that is needed for emmetropization. The pattern of peripheral astigmatism is not known in the chicken eye, a common model of myopia. Peripheral astigmatism was mapped out over the horizontal visual field in three chickens, 43 days old, and in three near emmetropic human subjects, average age 34.7years, using infrared photoretinoscopy. There were no differences in astigmatism between humans and chickens in the central visual field (chicks -0.35D, humans -0.65D, n.s.) but large differences in the periphery (i.e. astigmatism at 40° in the temporal visual field: humans -4.21D, chicks -0.63D, p<0.001, unpaired t-test). The lack of peripheral astigmatism in chicks was not due to differences in corneal shape. Perhaps related to their superior peripheral optics, we found that chickens had excellent visual performance also in the far periphery. Using an automated optokinetic nystagmus paradigm, no difference was observed in spatial visual performance with vision restricted to either the central 67° of the visual field or to the periphery beyond 67°. Accommodation was elicited by stimuli presented far out in the visual field. Transscleral images of single infrared LEDs showed no sign of peripheral astigmatism. The chick may be the first terrestrial vertebrate described to lack oblique astigmatism. Since corneal shape cannot account for the difference in astigmatism in humans and chicks, it must trace back to the design of the crystalline lens. The lack of peripheral astigmatism in chicks also excludes a role in emmetropization. Copyright © 2015 Elsevier Ltd. All rights reserved.
Compact sensitive instrument for direct ultrasonic visualization of defects.
Bar-Cohen, Y; Ben-Joseph, B; Harnik, E
1978-12-01
A simple ultrasonic imaging cell based on the confocal combination of a plano-concave lens and a concave spherical mirror is described. When used in conjunction with a stroboscopic schlieren visualization system, it has the main attributes of a practical nondestructive testing instrument: it is compact, relatively inexpensive, and simple to operate; its sensitivity is fair, resolution and fidelity are good; it has a fairly large field of view and a test piece can be readily scanned. The scope of its applicability is described and discussed.
Manolov, Rumen; Jamieson, Matthew; Evans, Jonathan J; Sierra, Vicenta
2015-09-01
Single-case data analysis still relies heavily on visual inspection, and, at the same time, it is not clear to what extent the results of different quantitative procedures converge in identifying an intervention effect and its magnitude when applied to the same data; this is the type of evidence provided here for two procedures. One of the procedures, included due to the importance of providing objective criteria to visual analysts, is a visual aid fitting and projecting split-middle trend while taking into account data variability. The other procedure converts several different metrics into probabilities making their results comparable. In the present study, we expore to what extend these two procedures coincide in the magnitude of intervention effect taking place in a set of studies stemming from a recent meta-analysis. The procedures concur to a greater extent with the values of the indices computed and with each other and, to a lesser extent, with our own visual analysis. For distinguishing smaller from larger effects, the probability-based approach seems somewhat better suited. Moreover, the results of the field test suggest that the latter is a reasonably good mechanism for translating different metrics into similar labels. User friendly R code is provided for promoting the use of the visual aid, together with a quantification based on nonoverlap and the label provided by the probability approach. © The Author(s) 2015.
New approach to estimating variability in visual field data using an image processing technique.
Crabb, D P; Edgar, D F; Fitzke, F W; McNaught, A I; Wynn, H P
1995-01-01
AIMS--A new framework for evaluating pointwise sensitivity variation in computerised visual field data is demonstrated. METHODS--A measure of local spatial variability (LSV) is generated using an image processing technique. Fifty five eyes from a sample of normal and glaucomatous subjects, examined on the Humphrey field analyser (HFA), were used to illustrate the method. RESULTS--Significant correlation between LSV and conventional estimates--namely, HFA pattern standard deviation and short term fluctuation, were found. CONCLUSION--LSV is not dependent on normals' reference data or repeated threshold determinations, thus potentially reducing test time. Also, the illustrated pointwise maps of LSV could provide a method for identifying areas of fluctuation commonly found in early glaucomatous field loss. PMID:7703196
Exploring eye movements in patients with glaucoma when viewing a driving scene.
Crabb, David P; Smith, Nicholas D; Rauscher, Franziska G; Chisholm, Catharine M; Barbur, John L; Edgar, David F; Garway-Heath, David F
2010-03-16
Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of 'point-of-regard' of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive.
Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene
Crabb, David P.; Smith, Nicholas D.; Rauscher, Franziska G.; Chisholm, Catharine M.; Barbur, John L.; Edgar, David F.; Garway-Heath, David F.
2010-01-01
Background Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). Methodology/Principal Findings The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of ‘point-of-regard’ of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Conclusions/Significance Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive. PMID:20300522
Feldon, Steven E
2004-01-01
ABSTRACT Purpose To validate a computerized expert system evaluating visual fields in a prospective clinical trial, the Ischemic Optic Neuropathy Decompression Trial (IONDT). To identify the pattern and within-pattern severity of field defects for study eyes at baseline and 6-month follow-up. Design Humphrey visual field (HVF) change was used as the outcome measure for a prospective, randomized, multi-center trial to test the null hypothesis that optic nerve sheath decompression was ineffective in treating nonarteritic anterior ischemic optic neuropathy and to ascertain the natural history of the disease. Methods An expert panel established criteria for the type and severity of visual field defects. Using these criteria, a rule-based computerized expert system interpreted HVF from baseline and 6-month visits for patients randomized to surgery or careful follow-up and for patients who were not randomized. Results A computerized expert system was devised and validated. The system was then used to analyze HVFs. The pattern of defects found at baseline for patients randomized to surgery did not differ from that of patients randomized to careful follow-up. The most common pattern of defect was a superior and inferior arcuate with central scotoma for randomized eyes (19.2%) and a superior and inferior arcuate for nonrandomized eyes (30.6%). Field patterns at 6 months and baseline were not different. For randomized study eyes, the superior altitudinal defects improved (P = .03), as did the inferior altitudinal defects (P = .01). For nonrandomized study eyes, only the inferior altitudinal defects improved (P = .02). No treatment effect was noted. Conclusions A novel rule-based expert system successfully interpreted visual field defects at baseline of eyes enrolled in the IONDT. PMID:15747764
Yamagata, Yoshitaka; Terada, Yuko; Suzuki, Atsushi; Mimura, Osamu
2010-01-01
The visual efficiency scale currently adopted to determine the legal grade of visual disability associated with visual field loss in Japan is not appropriate for the evaluation of disability regarding daily living activities. We investigated whether Esterman disability score (EDS) is suitable for the assessment of mobility difficulty in patients with visual field loss. The correlation between the EDS calculated from Goldmann's kinetic visual field and the degree of subjective mobility difficulty determined by a questionnaire was investigated in 164 patients with visual field loss. The correlation between the EDS determined using a program built into the Humphrey field analyzer and that calculated from Goldmann's kinetic visual field was also investigated. The EDS based on the kinetic visual field was correlated well with the degree of subjective mobility difficulty, and the EDS measured using the Humphrey field analyzer could be estimated from the kinetic visual field-based EDS. Instead of the currently adopted visual efficiency scale, EDS should be employed for the assessment of mobility difficulty in patients with visual field loss, also to establish new judgment criteria concerning the visual field.
Rosenblatt, Steven David; Crane, Benjamin Thomas
2015-01-01
A moving visual field can induce the feeling of self-motion or vection. Illusory motion from static repeated asymmetric patterns creates a compelling visual motion stimulus, but it is unclear if such illusory motion can induce a feeling of self-motion or alter self-motion perception. In these experiments, human subjects reported the perceived direction of self-motion for sway translation and yaw rotation at the end of a period of viewing set visual stimuli coordinated with varying inertial stimuli. This tested the hypothesis that illusory visual motion would influence self-motion perception in the horizontal plane. Trials were arranged into 5 blocks based on stimulus type: moving star field with yaw rotation, moving star field with sway translation, illusory motion with yaw, illusory motion with sway, and static arrows with sway. Static arrows were used to evaluate the effect of cognitive suggestion on self-motion perception. Each trial had a control condition; the illusory motion controls were altered versions of the experimental image, which removed the illusory motion effect. For the moving visual stimulus, controls were carried out in a dark room. With the arrow visual stimulus, controls were a gray screen. In blocks containing a visual stimulus there was an 8s viewing interval with the inertial stimulus occurring over the final 1s. This allowed measurement of the visual illusion perception using objective methods. When no visual stimulus was present, only the 1s motion stimulus was presented. Eight women and five men (mean age 37) participated. To assess for a shift in self-motion perception, the effect of each visual stimulus on the self-motion stimulus (cm/s) at which subjects were equally likely to report motion in either direction was measured. Significant effects were seen for moving star fields for both translation (p = 0.001) and rotation (p<0.001), and arrows (p = 0.02). For the visual motion stimuli, inertial motion perception was shifted in the direction consistent with the visual stimulus. Arrows had a small effect on self-motion perception driven by a minority of subjects. There was no significant effect of illusory motion on self-motion perception for either translation or rotation (p>0.1 for both). Thus, although a true moving visual field can induce self-motion, results of this study show that illusory motion does not.
Puberty as a risk factor for less favorable visual outcome in idiopathic intracranial hypertension.
Stiebel-Kalish, Hadas; Kalish, Yuval; Lusky, Moshe; Gaton, Dan D; Ehrlich, Rita; Shuper, Avinoam
2006-08-01
To test the hypothesis that puberty is a risk factor for poorer visual outcome in idiopathic intracranial hypertension (IIH). Retrospective chart review case series. Tertiary referral center, neuro-ophthalmology unit. Ninety-six patients with IIH followed for a minimum of one year. Age (grouped into prepubertal, pubertal, teenage, or adult), obesity, initial intracranial pressure (ICP), measurements and presence of hypertension, anemia, or renal failure were correlated with final visual outcome using chi(2), stepwise logistic regression, and model-selection log linear analyses. Visual outcome was graded into "excellent" -- no evidence of an optic neuropathy or any permanent visual field defect in either eye, "moderate"-- evidence of an optic neuropathy and/or a mild (nasal constriction) visual field defect, or "poor outcome" (peripheral constriction) -- permanent visual field defect. Outcome data were complete for 96 patients. Moderate to poor visual outcome, as opposed to excellent, was significantly associated with puberty (P = .007 using the gender-specific definition of puberty, .0002 using the broad definition). Moderate-poor visual outcome occurred in none of seven IIH patients of prepubertal age (<9 years), in 15 of 26 patients presenting between nine to 16 years, in two of six patients aged 17 to 22 years, and in seven of 57 adult patients over the age of 23 years. In this series of 96 patients with IIH, visual outcome was less favorable in pubertal patients than in prepubertal, teenage, and adult patients. We recommend that clinicians maintain a high index of awareness when caring for pubescent children with IIH.
International Practice in Care Provision for Post-stroke Visual Impairment.
Rowe, Fiona J
2017-09-01
This study sought to explore the practice of orthoptists internationally in care provision for poststroke visual impairment. Survey questions were developed and piloted with clinicians, academics, and users. Questions addressed types of visual problems, how these were identified, treated, and followed up, care pathways in use, links with other professions, and referral options. The survey was approved by the institutional ethical committee. The survey was accessed via a web link that was circulated through the International Orthoptic Association member professional organisations to orthoptists. Completed electronic surveys were obtained from 299 individuals. About one-third (35.5%) of orthoptists saw patients within 2 weeks of stroke onset and over half (55.5%) by 1 month post stroke. Stroke survivors were routinely assessed by 87%; over three-quarters in eye clinics. Screening tools were used by 11%. Validated tests were used for assessment of visual acuity (76.5%), visual field (68.2%), eye movement (80.9%), binocular vision (77.9%), and visual function (55.8%). Visual problems suspected by family or professionals were high (86.6%). Typical overall follow-up period of vision care was less than 3 months. Designated care pathways for stroke survivors with visual problems were used by 56.9% of orthoptists. Information on visual impairment was provided by 85.9% of orthoptists. In international orthoptic practice, there is general agreement on assessment and management of visual impairment in stroke populations. More than half of orthoptists reported seeing stroke survivors within 1 month of the stroke onset, typically in eye clinics. There was a high use of validated tests of visual acuity, visual fields, ocular motility, and binocular vision. Similarly there was high use of established treatment options including prisms, occlusion, compensatory strategies, and oculomotor training, appropriately targeted at specific types of visual conditions/symptoms. This information can be used to inform choice of core outcome orthoptic measures in stroke practice.
NASA Technical Reports Server (NTRS)
Erickson, Gary E.; Inenaga, Andrew S.
1994-01-01
Laser vapor screen (LVS) flow visualization systems that are fiber-optic based were developed and installed for aerodynamic research in the Langley 8-Foot Transonic Pressure Tunnel and the Langley 7- by 10-Foot High Speed Tunnel. Fiber optics are used to deliver the laser beam through the plenum shell that surrounds the test section of each facility and to the light-sheet-generating optics positioned in the ceiling window of the test section. Water is injected into the wind tunnel diffuser section to increase the relative humidity and promote condensation of the water vapor in the flow field about the model. The condensed water vapor is then illuminated with an intense sheet of laser light to reveal features of the flow field. The plenum shells are optically sealed; therefore, video-based systems are used to observe and document the flow field. Operational experience shows that the fiber-optic-based systems provide safe, reliable, and high-quality off-surface flow visualization in smaller and larger scale subsonic and transonic wind tunnels. The design, the installation, and the application of the Langley Research Center (LaRC) LVS flow visualization systems in larger scale wind tunnels are highlighted. The efficiency of the fiber optic LVS systems and their insensitivity to wind tunnel vibration, the tunnel operating temperature and pressure variations, and the airborne contaminants are discussed.
Testing memory for unseen visual stimuli in patients with extinction and spatial neglect.
Vuilleumier, Patrik; Schwartz, Sophie; Clarke, Karen; Husain, Masud; Driver, Jon
2002-08-15
Visual extinction after right parietal damage involves a loss of awareness for stimuli in the contralesional field when presented concurrently with ipsilesional stimuli, although contralesional stimuli are still perceived if presented alone. However, extinguished stimuli can still receive some residual on-line processing, without awareness. Here we examined whether such residual processing of extinguished stimuli can produce implicit and/or explicit memory traces lasting many minutes. We tested four patients with right parietal damage and left extinction on two sessions, each including distinct study and subsequent test phases. At study, pictures of objects were shown briefly in the right, left, or both fields. Patients were asked to name them without memory instructions (Session 1) or to make an indoor/outdoor categorization and memorize them (Session 2). They extinguished most left stimuli on bilateral presentation. During the test (up to 48 min later), fragmented pictures of the previously exposed objects (or novel objects) were presented alone in either field. Patients had to identify each object and then judge whether it had previously been exposed. Identification of fragmented pictures was better for previously exposed objects that had been consciously seen and critically also for objects that had been extinguished (as compared with novel objects), with no influence of the depth of processing during study. By contrast, explicit recollection occurred only for stimuli that were consciously seen at study and increased with depth of processing. These results suggest implicit but not explicit memory for extinguished visual stimuli in parietal patients.
Opposite brain laterality in analogous auditory and visual tests.
Oltedal, Leif; Hugdahl, Kenneth
2017-11-01
Laterality for language processing can be assessed by auditory and visual tasks. Typically, a right ear/right visual half-field (VHF) advantage is observed, reflecting left-hemispheric lateralization for language. Historically, auditory tasks have shown more consistent and reliable results when compared to VHF tasks. While few studies have compared analogous tasks applied to both sensory modalities for the same participants, one such study by Voyer and Boudreau [(2003). Cross-modal correlation of auditory and visual language laterality tasks: a serendipitous finding. Brain Cogn, 53(2), 393-397] found opposite laterality for visual and auditory language tasks. We adapted an experimental paradigm based on a dichotic listening and VHF approach, and applied the combined language paradigm in two separate experiments, including fMRI in the second experiment to measure brain activation in addition to behavioural data. The first experiment showed a right-ear advantage for the auditory task, but a left half-field advantage for the visual task. The second experiment, confirmed the findings, with opposite laterality effects for the visual and auditory tasks. In conclusion, we replicate the finding by Voyer and Boudreau (2003) and support their interpretation that these visual and auditory language tasks measure different cognitive processes.
ERIC Educational Resources Information Center
Hamilton, Robert
2014-01-01
In this study, the prototype of a new type of bilingual picture book was field-tested with two sets of mother-son subject pairs. This picture book was designed as a possible tool for providing children with comprehensible input during their critical period for second language acquisition. Context is provided by visual cues and both Japanese and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ragan, Eric D.; Bowman, Doug A.; Kopper, Regis
Virtual reality training systems are commonly used in a variety of domains, and it is important to understand how the realism of a training simulation influences training effectiveness. The paper presents a framework for evaluating the effects of virtual reality fidelity based on an analysis of a simulation’s display, interaction, and scenario components. Following this framework, we conducted a controlled experiment to test the effects of fidelity on training effectiveness for a visual scanning task. The experiment varied the levels of field of view and visual realism during a training phase and then evaluated scanning performance with the simulator’s highestmore » level of fidelity. To assess scanning performance, we measured target detection and adherence to a prescribed strategy. The results show that both field of view and visual realism significantly affected target detection during training; higher field of view led to better performance and higher visual realism worsened performance. Additionally, the level of visual realism during training significantly affected learning of the prescribed visual scanning strategy, providing evidence that high visual realism was important for learning the technique. The results also demonstrate that task performance during training was not always a sufficient measure of mastery of an instructed technique. That is, if learning a prescribed strategy or skill is the goal of a training exercise, performance in a simulation may not be an appropriate indicator of effectiveness outside of training—evaluation in a more realistic setting may be necessary.« less
Spatiotemporal analysis of brightness induction
McCourt, Mark E.
2011-01-01
Brightness induction refers to a class of visual illusions in which the perceived intensity of a region of space is influenced by the luminance of surrounding regions. These illusions are significant because they provide insight into the neural organization of the visual system. A novel quadrature-phase motion cancelation technique was developed to measure the magnitude of the grating induction brightness illusion across a wide range of spatial frequencies, temporal frequencies and test field heights. Canceling contrast is greatest at low frequencies and declines with increasing frequency in both dimensions, and with increasing test field height. Canceling contrast scales as the product of inducing grating spatial frequency and test field height (the number of inducing grating cycles per test field height). When plotted using a spatial axis which indexes this product, the spatiotemporal induction surfaces for four test field heights can be described as four partially overlapping sections of a single larger surface. These properties of brightness induction are explained in the context of multiscale spatial filtering. The present study is the first to measure the magnitude of grating induction as a function of temporal frequency. Taken in conjunction with several other studies (Blakeslee & McCourt, 2008; Robinson & de Sa, 2008; Magnussen & Glad, 1975) the results of this study illustrate that at least one form of brightness induction is very much faster than that reported by DeValois et al. (1986) and Rossi and Paradiso (1996), and are inconsistent with the proposition that brightness induction results from a slow “filling in” process. PMID:21763339
Transient Retinal Dysfunctions after Acute Cannabis Use.
Schwitzer, Thomas; Robert, Matthieu P; Giersch, Anne; Angioi-Duprez, Karine; Ingster-Moati, Isabelle; Pon-Monnier, Amandine; Schwan, Raymund; Laprevote, Vincent
2016-01-01
Although cannabis is very widespread worldwide, the impact of cannabis on visual function remains poorly understood. This is partly due to numerous difficulties met in developing clinical studies in cannabis users. Here, we report the first documented case of neuroretinal dysfunction after acute cannabis smoking. This observation was favored by the need of an annual ophthalmic evaluation in the context of a chloroquine intake for a systemic lupus erythematosus in a 47-year-old heavy cannabis user. A complete ophthalmic evaluation including visual acuity tests, intraocular pressure, fundoscopic examination, automated 10° central visual field, full-field electroretinogram (ERG) and multifocal ERG was performed twice - 30 min and 5 h after cannabis smoking. A strong decrease (up to 48%) in the a-wave amplitude of the full-field ERG was measured 30 min after cannabis smoking for all scotopic responses compared with the responses 5 h after smoking. Other tests showed reproducible results between the 2 series of measurements. This clinical case suggests that acute inhalation of cannabis affects the photoreceptors functioning. This rare situation suggests further investigations are required on the impact of cannabis on retinal processing, especially since cannabis has been incriminated in car injuries. © 2016 S. Karger AG, Basel.
Impairing the useful field of view in natural scenes: Tunnel vision versus general interference.
Ringer, Ryan V; Throneburg, Zachary; Johnson, Aaron P; Kramer, Arthur F; Loschky, Lester C
2016-01-01
A fundamental issue in visual attention is the relationship between the useful field of view (UFOV), the region of visual space where information is encoded within a single fixation, and eccentricity. A common assumption is that impairing attentional resources reduces the size of the UFOV (i.e., tunnel vision). However, most research has not accounted for eccentricity-dependent changes in spatial resolution, potentially conflating fixed visual properties with flexible changes in visual attention. Williams (1988, 1989) argued that foveal loads are necessary to reduce the size of the UFOV, producing tunnel vision. Without a foveal load, it is argued that the attentional decrement is constant across the visual field (i.e., general interference). However, other research asserts that auditory working memory (WM) loads produce tunnel vision. To date, foveal versus auditory WM loads have not been compared to determine if they differentially change the size of the UFOV. In two experiments, we tested the effects of a foveal (rotated L vs. T discrimination) task and an auditory WM (N-back) task on an extrafoveal (Gabor) discrimination task. Gabor patches were scaled for size and processing time to produce equal performance across the visual field under single-task conditions, thus removing the confound of eccentricity-dependent differences in visual sensitivity. The results showed that although both foveal and auditory loads reduced Gabor orientation sensitivity, only the foveal load interacted with retinal eccentricity to produce tunnel vision, clearly demonstrating task-specific changes to the form of the UFOV. This has theoretical implications for understanding the UFOV.
Development of a Signal Data Converter for an Airport Visibility Measuring System
DOT National Transportation Integrated Search
1975-08-01
This report briefly describes the evolution of the FAA/NBS Runway Visual Range RVR transmissometer system into a breadboard Airport Visibility Measuring System (ARVIS) which has been laboratory tested and which will undergo field tests at the Nationa...
Jabs, Douglas A.; Ahuja, Alka; Van Natta, Mark L.; Lyon, Alice T.; Yeh, Steven; Danis, Ronald
2015-01-01
Objectives To describe the long-term outcomes of patients with cytomegalovirus (CMV) retinitis and the acquired immunodeficiency syndrome (AIDS)in the modern era of combination antiretroviral therapy. Design Prospective, observational, cohort study Participants Patients with AIDS and CMV retinitis Testing Immune recovery, defined as a CD4+ T cell count>100 cells/μL for ≥ 3 months. Main outcome measures Mortality, visual impairment (visual acuity worse than 20/40) and blindness (visual acuity 20/200 or worse) on logarithmic visual acuity charts, loss of visual field on quantitative Goldmann perimetry. Results Patients without immune recovery had a mortality of 44.4/100 person years (PY), and a median survival of 13.5 months after the diagnosis of CMV retinitis, whereas those with immune recovery had a mortality of 2.7/100 PY (P<0.001), and an estimated median survival of 27.0 years after the diagnosis of CMV retinitis. The rates of bilateral visual impairment and blindness were 0.9/100 PY and 0.4/100 PY, respectively, and were similar between those with and without immune recovery. Among those with immune recovery, the rate of visual field loss was ~1% of the normal field/year, whereas among those without immune recovery it was ~7% of the normal field/year. Conclusions Among persons with CMV retinitis and AIDS, if there is immune recovery, long-term survival is likely, whereas if there is no immune recovery, the mortality rate is substantial. Although higher than the rates seen in the non-HIV-infected population, the rates of bilateral visual impairment and blindness are low, especially when compared to rates seen in the era before modern antiretroviral therapy. PMID:25892019
Gall, Carolin; Silvennoinen, Katri; Granata, Giuseppe; de Rossi, Francesca; Vecchio, Fabrizio; Brösel, Doreen; Bola, Michał; Sailer, Michael; Waleszczyk, Wioletta J; Rossini, Paolo M; Tatlisumak, Turgut; Sabel, Bernhard A
2015-07-01
Occipital stroke often leads to visual field loss, for which no effective treatment exists. Little is known about the potential of non-invasive electric current stimulation to ameliorate visual functions in patients suffering from unilateral occipital stroke. One reason is the traditional thinking that visual field loss after brain lesions is permanent. Since evidence is available documenting vision restoration by means of vision training or non-invasive electric current stimulation future studies should also consider investigating recovery processes after visual cortical strokes. Here, protocols of repetitive transorbital alternating current stimulation (rtACS) and transcranial direct current stimulation (tDCS) are presented and the European consortium for restoration of vision (REVIS) is introduced. Within the consortium different stimulation approaches will be applied to patients with unilateral occipital strokes resulting in homonymous hemianopic visual field defects. The aim of the study is to evaluate effects of current stimulation of the brain on vision parameters, vision-related quality of life, and physiological parameters that allow concluding about the mechanisms of vision restoration. These include EEG-spectra and coherence measures, and visual evoked potentials. The design of stimulation protocols involves an appropriate sham-stimulation condition and sufficient follow-up periods to test whether the effects are stable. This is the first application of non-invasive current stimulation for vision rehabilitation in stroke-related visual field deficits. Positive results of the trials could have far-reaching implications for clinical practice. The ability of non-invasive electrical current brain stimulation to modulate the activity of neuronal networks may have implications for stroke rehabilitation also in the visual domain. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao
2013-01-02
Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.
Heinemann, Christian; Schliemann-Willers, Sibylle; Oberthür, Christine; Hamburger, Matthias; Elsner, Peter
2004-05-01
Lipophilic extracts of Isatis tinctoria L. exhibit significant activity against several clinically relevant targets of inflammation. The alkaloid tryptanthrin was identified as one of the active principles in woad and characterised as a potent dual inhibitor of COX-2 and 5-LOX. Here, the anti-inflammatory efficacy of topical application of three different Isatis extracts and tryptanthrin was investigated in human volunteers. Two different models were used, namely the sodium lauryl sulphate (SLS)-induced irritant contact dermatitis (ICD) and UVB-induced erythema. Twenty healthy volunteers without any skin disease participated in the study. Cumulative irritant contact dermatitis was induced on test fields on the volunteers' backs by twice daily application of 0.5 % sodium lauryl sulphate over a period of four days. Half of the test fields were treated with the test substances during the eliciting phase, while the remaining test fields were treated over a period of 4 days after induction of dermatitis. In the second model, a UVB erythema on the volunteers' lower backs was induced using the double minimal erythema dose (MED). Twenty-four hours after irradiation the test fields were treated with the test substances over a period of 3 days. All reactions were assessed visually and by non-invasive bioengineering methods (evaporimetry and chromametry). Treatment with extracts during the ICD eliciting phase led to a significantly smaller increase of visual scores and transepidermal water loss compared to the untreated test field. For tryptanthrin this benefit was also observed, but the improvement was not statistically significant. When treatment was performed after completing the eliciting phase, accelerated resolution of the irritant reaction could not be observed. In the UVB erythema model anti-inflammatory effects of the test substances were not observed.
Vision and night driving abilities of elderly drivers.
Gruber, Nicole; Mosimann, Urs P; Müri, René M; Nef, Tobias
2013-01-01
In this article, we review the impact of vision on older people's night driving abilities. Driving is the preferred and primary mode of transport for older people. It is a complex activity where intact vision is seminal for road safety. Night driving requires mesopic rather than scotopic vision, because there is always some light available when driving at night. Scotopic refers to night vision, photopic refers to vision under well-lit conditions, and mesopic vision is a combination of photopic and scotopic vision in low but not quite dark lighting situations. With increasing age, mesopic vision decreases and glare sensitivity increases, even in the absence of ocular diseases. Because of the increasing number of elderly drivers, more drivers are affected by night vision difficulties. Vision tests, which accurately predict night driving ability, are therefore of great interest. We reviewed existing literature on age-related influences on vision and vision tests that correlate or predict night driving ability. We identified several studies that investigated the relationship between vision tests and night driving. These studies found correlations between impaired mesopic vision or increased glare sensitivity and impaired night driving, but no correlation was found among other tests; for example, useful field of view or visual field. The correlation between photopic visual acuity, the most commonly used test when assessing elderly drivers, and night driving ability has not yet been fully clarified. Photopic visual acuity alone is not a good predictor of night driving ability. Mesopic visual acuity and glare sensitivity seem relevant for night driving. Due to the small number of studies evaluating predictors for night driving ability, further research is needed.
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Multispectral image analysis for object recognition and classification
NASA Astrophysics Data System (ADS)
Viau, C. R.; Payeur, P.; Cretu, A.-M.
2016-05-01
Computer and machine vision applications are used in numerous fields to analyze static and dynamic imagery in order to assist or automate decision-making processes. Advancements in sensor technologies now make it possible to capture and visualize imagery at various wavelengths (or bands) of the electromagnetic spectrum. Multispectral imaging has countless applications in various fields including (but not limited to) security, defense, space, medical, manufacturing and archeology. The development of advanced algorithms to process and extract salient information from the imagery is a critical component of the overall system performance. The fundamental objective of this research project was to investigate the benefits of combining imagery from the visual and thermal bands of the electromagnetic spectrum to improve the recognition rates and accuracy of commonly found objects in an office setting. A multispectral dataset (visual and thermal) was captured and features from the visual and thermal images were extracted and used to train support vector machine (SVM) classifiers. The SVM's class prediction ability was evaluated separately on the visual, thermal and multispectral testing datasets.
Position Information Encoded by Population Activity in Hierarchical Visual Areas
Majima, Kei; Horikawa, Tomoyasu
2017-01-01
Abstract Neurons in high-level visual areas respond to more complex visual features with broader receptive fields (RFs) compared to those in low-level visual areas. Thus, high-level visual areas are generally considered to carry less information regarding the position of seen objects in the visual field. However, larger RFs may not imply loss of position information at the population level. Here, we evaluated how accurately the position of a seen object could be predicted (decoded) from activity patterns in each of six representative visual areas with different RF sizes [V1–V4, lateral occipital complex (LOC), and fusiform face area (FFA)]. We collected functional magnetic resonance imaging (fMRI) responses while human subjects viewed a ball randomly moving in a two-dimensional field. To estimate population RF sizes of individual fMRI voxels, RF models were fitted for individual voxels in each brain area. The voxels in higher visual areas showed larger estimated RFs than those in lower visual areas. Then, the ball’s position in a separate session was predicted by maximum likelihood estimation using the RF models of individual voxels. We also tested a model-free multivoxel regression (support vector regression, SVR) to predict the position. We found that regardless of the difference in RF size, all visual areas showed similar prediction accuracies, especially on the horizontal dimension. Higher areas showed slightly lower accuracies on the vertical dimension, which appears to be attributed to the narrower spatial distributions of the RF centers. The results suggest that much position information is preserved in population activity through the hierarchical visual pathway regardless of RF sizes and is potentially available in later processing for recognition and behavior. PMID:28451634
Mobility performance in glaucoma.
Turano, K A; Rubin, G S; Quigley, H A
1999-11-01
To determine whether glaucoma affects mobility performance and whether there is a relationship between mobility performance and stage of disease as estimated from vision-function measures. The mobility performance of 47 glaucoma subjects was compared with that of 47 normal-vision subjects who were of similar age. Mobility performance was assessed by the time required to complete an established travel path and the number of mobility incidents. The subjective assessment of falling and fear of falling were also compared. Vision function was assessed by measures of visual acuity, contrast sensitivity, monocular automated threshold perimetry, and suprathreshold; binocular visual fields were assessed with the Esterman test. The glaucoma subjects walked on average 10% more slowly than did the normal-vision subjects. The number of people who experienced bumps, stumbles, or orientation problems was almost twice as high in the glaucoma group than the normal-vision group, but the difference did not reach statistical significance. The difference between groups also was not significant with respect to the number of people who reported falling in the past year (38% for the glaucoma group and 30% for the normal-vision group) or a fear of falling (28% for the glaucoma group and 23% for the normal-vision group). The visual fields assessed with a Humphrey 24-2 test were more highly correlated with walking speed in glaucoma than the visual fields scored by the Esterman scale or than visual acuity or contrast sensitivity. Glaucoma is associated with a modest decrease in mobility performance. Walking speed decreases with severity of the disease as estimated by threshold perimetry.
Glaucoma management in patients with osteo-odonto-keratoprosthesis (OOKP): the Singapore OOKP Study.
Kumar, Rajesh S; Tan, Donald T H; Por, Yong-Ming; Oen, Francis T; Hoh, Sek-Tien; Parthasarathy, Anand; Aung, Tin
2009-01-01
To report diagnostic modalities and treatment options for glaucoma in eyes with osteo-odonto keratoprosthesis (OOKP). Eyes that underwent OOKP were evaluated for glaucoma at the time of the first postoperative visit, then at 1 and 3 months after the procedure, and thereafter every 6 months. All eyes underwent stereo-biomicroscopic optic nerve head (ONH) assessment, kinetic (Goldmann perimetry) and automated static visual field testing, ONH photography, Heidelberg retina tomograph, scanning laser polarimetery (GDx), and optical coherence tomography. Treatment of glaucoma was also reviewed. Average follow-up period was 19.1 (range: 5 to 31) months. Of the 15 eyes that underwent OOKP, 5 eyes had preexisting glaucoma. None of the other 10 eyes developed glaucoma after OOKP. ONH photography and visual field testing were the most reliable methods to assess status of the disease, whereas Heidelberg retina tomograph and optical coherence tomography could be performed with reasonable reproducibility and quality; GDx imaging was poor. All patients with glaucoma were treated with oral acetazolamide 500 mg twice a day. Transscleral cyclophotocoagulation was performed in 3 eyes at stage 2 of OOKP surgery. Progression of glaucoma was noted in 2 eyes on the basis of optic disc photographs and automated perimetry. Visual field testing and optic disc assessment with optic disc photographs seem to be effective methods to monitor eyes with OOKP for glaucoma. Treatment strategies include oral medications to lower intraocular pressure and cyclophotocoagulation.
Zalesinska, Malgorzata
2018-08-01
A proper visual performance by drivers can be ensured by, among else, a correct distribution of luminance in their field of view. At night, when the driver's sight is adapted to low luminance levels, high luminance level objects located near the road may be a source of glare, which is not only a nuisance, but it may also blind the driver. For many years, LED billboards (light-emitting diode billboards) have been installed near roads. Such billboards are usually large, have high luminance and show dynamically changing images. These parameters have a significant impact on the drivers' visual performance and, in turn, on road traffic safety. The study on the impact of the luminance, size and location of LED billboards on the drivers' visual performance was conducted on a volunteer group. Testing the impact of LED billboards on the visual performance of drivers in real-life conditions is very difficult. Therefore, the tests have been conducted in laboratory conditions, using a car driving simulator. The paper describes the testing procedure and tests results. The permissible luminance and areas of LED screens in two locations near the road, which significantly reduce the drivers' visual performance in municipal traffic at night, were determined by conducting an analysis of the results. Recommendations on the permissible luminance and areas of LED billboards were formulated. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vision in laboratory rodents-Tools to measure it and implications for behavioral research.
Leinonen, Henri; Tanila, Heikki
2017-07-29
Mice and rats are nocturnal mammals and their vision is specialized for detection of motion and contrast in dim light conditions. These species possess a large proportion of UV-sensitive cones in their retinas and the majority of their optic nerve axons target superior colliculus rather than visual cortex. Therefore, it was a widely held belief that laboratory rodents hardly utilize vision during day-time behavior. This dogma is being questioned as accumulating evidence suggests that laboratory rodents are able to perform complex visual functions, such as perceiving subjective contours, and that declined vision may affect their performance in many behavioral tasks. For instance, genetic engineering may have unexpected consequences on vision as mouse models of Alzheimer's and Huntington's diseases have declined visual function. Rodent vision can be tested in numerous ways using operant training or reflex-based behavioral tasks, or alternatively using electrophysiological recordings. In this article, we will first provide a summary of visual system and explain its characteristics unique to rodents. Then, we present well-established techniques to test rodent vision, with an emphasis on pattern vision: visual water test, optomotor reflex test, pattern electroretinography and pattern visual evoked potentials. Finally, we highlight the importance of visual phenotyping in rodents. As the number of genetically engineered rodent models and volume of behavioral testing increase simultaneously, the possibility of visual dysfunctions needs to be addressed. Neglect in this matter potentially leads to crude biases in the field of neuroscience and beyond. Copyright © 2017 Elsevier B.V. All rights reserved.
The Impact of Feedback on Self-Rated Driving Ability and Driving Self-Regulation among Older Adults
ERIC Educational Resources Information Center
Ackerman, Michelle L.; Crowe, Michael; Vance, David E.; Wadley, Virginia G.; Owsley, Cynthia; Ball, Karlene K.
2011-01-01
In 129 community-dwelling older adults, feedback regarding qualification for an insurance discount (based on a visual speed of processing test; Useful Field of View) was examined as a prospective predictor of change in self-reported driving ability, driving avoidance, and driving exposure over 3 months, along with physical, visual, health, and…
14 CFR 61.1 - Applicability and definitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Administrator to conduct a pilot proficiency test or a practical test for an airman certificate or rating issued under this part, or a person who is authorized to conduct a knowledge test under this part. (5) Flight... a visual system that provides at least a 45 degree horizontal field of view and a 30 degree vertical...
Redmond, Tony; O'Leary, Neil; Hutchison, Donna M; Nicolela, Marcelo T; Artes, Paul H; Chauhan, Balwantray C
2013-12-01
A new analysis method called permutation of pointwise linear regression measures the significance of deterioration over time at each visual field location, combines the significance values into an overall statistic, and then determines the likelihood of change in the visual field. Because the outcome is a single P value, individualized to that specific visual field and independent of the scale of the original measurement, the method is well suited for comparing techniques with different stimuli and scales. To test the hypothesis that frequency-doubling matrix perimetry (FDT2) is more sensitive than standard automated perimetry (SAP) in identifying visual field progression in glaucoma. Patients with open-angle glaucoma and healthy controls were examined by FDT2 and SAP, both with the 24-2 test pattern, on the same day at 6-month intervals in a longitudinal prospective study conducted in a hospital-based setting. Only participants with at least 5 examinations were included. Data were analyzed with permutation of pointwise linear regression. Permutation of pointwise linear regression is individualized to each participant, in contrast to current analyses in which the statistical significance is inferred from population-based approaches. Analyses were performed with both total deviation and pattern deviation. Sixty-four patients and 36 controls were included in the study. The median age, SAP mean deviation, and follow-up period were 65 years, -2.6 dB, and 5.4 years, respectively, in patients and 62 years, +0.4 dB, and 5.2 years, respectively, in controls. Using total deviation analyses, statistically significant deterioration was identified in 17% of patients with FDT2, in 34% of patients with SAP, and in 14% of patients with both techniques; in controls these percentages were 8% with FDT2, 31% with SAP, and 8% with both. Using pattern deviation analyses, statistically significant deterioration was identified in 16% of patients with FDT2, in 17% of patients with SAP, and in 3% of patients with both techniques; in controls these values were 3% with FDT2 and none with SAP. No evidence was found that FDT2 is more sensitive than SAP in identifying visual field deterioration. In about one-third of healthy controls, age-related deterioration with SAP reached statistical significance.
Rowe, Fiona J; Wright, David; Brand, Darren; Jackson, Carole; Harrison, Shirley; Maan, Tallat; Scott, Claire; Vogwell, Linda; Peel, Sarah; Akerman, Nicola; Dodridge, Caroline; Howard, Claire; Shipman, Tracey; Sperring, Una; Macdiarmid, Sonia; Freeman, Cicely
2013-01-01
To profile site of stroke/cerebrovascular accident, type and extent of field loss, treatment options, and outcome. Prospective multicentre cohort trial. Standardised referral and investigation protocol of visual parameters. 915 patients were recruited with a mean age of 69 years (SD 14). 479 patients (52%) had visual field loss. 51 patients (10%) had no visual symptoms. Almost half of symptomatic patients (n = 226) complained only of visual field loss: almost half (n = 226) also had reading difficulty, blurred vision, diplopia, and perceptual difficulties. 31% (n = 151) had visual field loss as their only visual impairment: 69% (n = 328) had low vision, eye movement deficits, or visual perceptual difficulties. Occipital and parietal lobe strokes most commonly caused visual field loss. Treatment options included visual search training, visual awareness, typoscopes, substitutive prisms, low vision aids, refraction, and occlusive patches. At followup 15 patients (7.5%) had full recovery, 78 (39%) had improvement, and 104 (52%) had no recovery. Two patients (1%) had further decline of visual field. Patients with visual field loss had lower quality of life scores than stroke patients without visual impairment. Stroke survivors with visual field loss require assessment to accurately define type and extent of loss, diagnose coexistent visual impairments, and offer targeted treatment.
Murphy, Matthew C; Conner, Ian P; Teng, Cindy Y; Lawrence, Jesse D; Safiullah, Zaid; Wang, Bo; Bilonick, Richard A; Kim, Seong-Gi; Wollstein, Gadi; Schuman, Joel S; Chan, Kevin C
2016-08-11
Glaucoma is the second leading cause of blindness worldwide and its pathogenesis remains unclear. In this study, we measured the structure, metabolism and function of the visual system by optical coherence tomography and multi-modal magnetic resonance imaging in healthy subjects and glaucoma patients with different degrees of vision loss. We found that inner retinal layer thinning, optic nerve cupping and reduced visual cortex activity occurred before patients showed visual field impairment. The primary visual cortex also exhibited more severe functional deficits than higher-order visual brain areas in glaucoma. Within the visual cortex, choline metabolism was perturbed along with increasing disease severity in the eye, optic radiation and visual field. In summary, this study showed evidence that glaucoma deterioration is already present in the eye and the brain before substantial vision loss can be detected clinically using current testing methods. In addition, cortical cholinergic abnormalities are involved during trans-neuronal degeneration and can be detected non-invasively in glaucoma. The current results can be of impact for identifying early glaucoma mechanisms, detecting and monitoring pathophysiological events and eye-brain-behavior relationships, and guiding vision preservation strategies in the visual system, which may help reduce the burden of this irreversible but preventable neurodegenerative disease.
Retinal Structures and Visual Cortex Activity are Impaired Prior to Clinical Vision Loss in Glaucoma
Murphy, Matthew C.; Conner, Ian P.; Teng, Cindy Y.; Lawrence, Jesse D.; Safiullah, Zaid; Wang, Bo; Bilonick, Richard A.; Kim, Seong-Gi; Wollstein, Gadi; Schuman, Joel S.; Chan, Kevin C.
2016-01-01
Glaucoma is the second leading cause of blindness worldwide and its pathogenesis remains unclear. In this study, we measured the structure, metabolism and function of the visual system by optical coherence tomography and multi-modal magnetic resonance imaging in healthy subjects and glaucoma patients with different degrees of vision loss. We found that inner retinal layer thinning, optic nerve cupping and reduced visual cortex activity occurred before patients showed visual field impairment. The primary visual cortex also exhibited more severe functional deficits than higher-order visual brain areas in glaucoma. Within the visual cortex, choline metabolism was perturbed along with increasing disease severity in the eye, optic radiation and visual field. In summary, this study showed evidence that glaucoma deterioration is already present in the eye and the brain before substantial vision loss can be detected clinically using current testing methods. In addition, cortical cholinergic abnormalities are involved during trans-neuronal degeneration and can be detected non-invasively in glaucoma. The current results can be of impact for identifying early glaucoma mechanisms, detecting and monitoring pathophysiological events and eye-brain-behavior relationships, and guiding vision preservation strategies in the visual system, which may help reduce the burden of this irreversible but preventable neurodegenerative disease. PMID:27510406
Reinke, Karen S.; LaMontagne, Pamela J.; Habib, Reza
2011-01-01
Spatial attention has been argued to be adaptive by enhancing the processing of visual stimuli within the ‘spotlight of attention’. We previously reported that crude threat cues (backward masked fearful faces) facilitate spatial attention through a network of brain regions consisting of the amygdala, anterior cingulate and contralateral visual cortex. However, results from previous functional magnetic resonance imaging (fMRI) dot-probe studies have been inconclusive regarding a fearful face-elicited contralateral modulation of visual targets. Here, we tested the hypothesis that the capture of spatial attention by crude threat cues would facilitate processing of subsequently presented visual stimuli within the masked fearful face-elicited ‘spotlight of attention’ in the contralateral visual cortex. Participants performed a backward masked fearful face dot-probe task while brain activity was measured with fMRI. Masked fearful face left visual field trials enhanced activity for spatially congruent targets in the right superior occipital gyrus, fusiform gyrus and lateral occipital complex, while masked fearful face right visual field trials enhanced activity in the left middle occipital gyrus. These data indicate that crude threat elicited spatial attention enhances the processing of subsequent visual stimuli in contralateral occipital cortex, which may occur by lowering neural activation thresholds in this retinotopic location. PMID:20702500
Visual Function in Carriers of X-linked Retinitis Pigmentosa
Comander, Jason; Weigel-DiFranco, Carol; Sandberg, Michael A.; Berson, Eliot L.
2015-01-01
Purpose To determine the frequency and severity of visual function loss in female carriers of X-linked retinitis pigmentosa (XLRP). Design Case series. Participants XLRP carriers with cross-sectional data (n = 242) and longitudinal data (n = 34, median follow-up: 16 years, follow-up range: 3–37 years). Half of the carriers were from RPGR- or RP2-genotyped families. Methods Retrospective medical records review. Main Outcome Measures Visual acuities, visual field areas, final dark adaptation thresholds, and full-field ERGs to 0.5 Hz and 30 Hz flashes. Results In genotyped families, 40% of carriers showed a baseline abnormality on at least one of the three psychophysical tests. There was a wide range of function among carriers; for example 3 of 121 (2%) of genotyped carriers were legally blind due to poor visual acuity, some as young as 35 years of age. Visual fields were less affected than visual acuity. In all carriers, the average ERG amplitude to 30 Hz flashes was about 50% of normal, and the average exponential rate of amplitude loss over time was half that of XLRP males (3.7%/year vs 7.4%/year, respectively). Among obligate carriers with affected fathers and/or sons, 53 of 55 (96%) had abnormal baseline ERGs. Some carriers who initially had completely normal fundi in both eyes went on to develop moderately decreased vision, though not legal blindness. Among carriers with RPGR mutations, those with mutations in ORF15, compared to those in exons 1–14, had worse final dark adaptation thresholds and lower 0.5 Hz and 30 Hz ERG amplitudes. Conclusions Most carriers of XLRP had mildly or moderately reduced visual function but rarely became legally blind. In most cases, obligate carriers could be identified by ERG testing. Carriers of RPGR ORF15 mutations tended to have worse visual function than carriers of RPGR exon 1–14 mutations. Since XLRP carrier ERG amplitudes and decay rates over time were on average half of those of affected males, these observations were consistent with the Lyon hypothesis of random X-inactivation. PMID:26143542
NASA Astrophysics Data System (ADS)
Nakakita, K.
2017-02-01
Simultaneous visualization technique of the combination of the unsteady Pressure-Sensitive Paint and the Schlieren measurement was introduced. It was applied to a wind tunnel test of a rocket faring model at the JAXA 2mx2m transonic wind tunnel. Quantitative unsteady pressure field was acquired by the unsteady PSP measurement, which consisted of a high-speed camera, high-power laser diode, and so on. Qualitative flow structure was acquired by the Schlieren measurement using a high-speed camera and Xenon lamp with a blue optical filter. Simultaneous visualization was achieved 1.6 kfps frame rate and it gave the detailed structure of unsteady flow fields caused by the unsteady shock wave oscillation due to shock-wave/boundary-layer interaction around the juncture between cone and cylinder on the model. Simultaneous measurement results were merged into a movie including surface pressure distribution on the rocket faring and spatial structure of shock wave system concerning to transonic buffet. Constructed movie gave a timeseries and global information of transonic buffet flow field on the rocket faring model visually.
Longitudinal changes in the visual field and optic disc in glaucoma.
Artes, Paul H; Chauhan, Balwantray C
2005-05-01
The nature and mode of functional and structural progression in open-angle glaucoma is a subject of considerable debate in the literature. While there is a traditionally held viewpoint that optic disc and/or nerve fibre layer changes precede visual field changes, there is surprisingly little published evidence from well-controlled prospective studies in this area, specifically with modern perimetric and imaging techniques. In this paper, we report on clinical data from both glaucoma patients and normal controls collected prospectively over several years, to address the relationship between visual field and optic disc changes in glaucoma using standard automated perimetry (SAP), high-pass resolution perimetry (HRP) and confocal scanning laser tomography (CSLT). We use several methods of analysis of longitudinal data and describe a new technique called "evidence of change" analysis which facilitates comparison between different tests. We demonstrate that current clinical indicators of visual function (SAP and HRP) and measures of optic disc structure (CSLT) provide largely independent measures of progression. We discuss the reasons for these findings as well as several methodological issues that pose challenges to elucidating the true structure-function relationship in glaucoma.
The Pivotal Role of the Right Parietal Lobe in Temporal Attention.
Agosta, Sara; Magnago, Denise; Tyler, Sarah; Grossman, Emily; Galante, Emanuela; Ferraro, Francesco; Mazzini, Nunzia; Miceli, Gabriele; Battelli, Lorella
2017-05-01
The visual system is extremely efficient at detecting events across time even at very fast presentation rates; however, discriminating the identity of those events is much slower and requires attention over time, a mechanism with a much coarser resolution [Cavanagh, P., Battelli, L., & Holcombe, A. O. Dynamic attention. In A. C. Nobre & S. Kastner (Eds.), The Oxford handbook of attention (pp. 652-675). Oxford: Oxford University Press, 2013]. Patients affected by right parietal lesion, including the TPJ, are severely impaired in discriminating events across time in both visual fields [Battelli, L., Cavanagh, P., & Thornton, I. M. Perception of biological motion in parietal patients. Neuropsychologia, 41, 1808-1816, 2003]. One way to test this ability is to use a simultaneity judgment task, whereby participants are asked to indicate whether two events occurred simultaneously or not. We psychophysically varied the frequency rate of four flickering disks, and on most of the trials, one disk (either in the left or right visual field) was flickering out-of-phase relative to the others. We asked participants to report whether two left-or-right-presented disks were simultaneous or not. We tested a total of 23 right and left parietal lesion patients in Experiment 1, and only right parietal patients showed impairment in both visual fields while their low-level visual functions were normal. Importantly, to causally link the right TPJ to the relative timing processing, we ran a TMS experiment on healthy participants. Participants underwent three stimulation sessions and performed the same simultaneity judgment task before and after 20 min of low-frequency inhibitory TMS over right TPJ, left TPJ, or early visual area as a control. rTMS over the right TPJ caused a bilateral impairment in the simultaneity judgment task, whereas rTMS over left TPJ or over early visual area did not affect performance. Altogether, our results directly link the right TPJ to the processing of relative time.
How does glaucoma look?: patient perception of visual field loss.
Crabb, David P; Smith, Nicholas D; Glen, Fiona C; Burton, Robyn; Garway-Heath, David F
2013-06-01
To explore patient perception of vision loss in glaucoma and, specifically, to test the hypothesis that patients do not recognize their impairment as a black tunnel effect or as black patches in their field of view. Clinic-based cross-sectional study. Fifty patients (age range, 52-82 years) with visual acuity better than 20/30 and with a range of glaucomatous visual field (VF) defects in both eyes, excluding those with very advanced disease (perimetrically blind). Participants underwent monocular VF testing in both eyes using a Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA; 24-2 Swedish interactive threshold algorithm standard tests) and other tests of visual function. Participants took part in a recorded interview during which they were asked if they were aware of their VF loss; if so, there were encouraged to describe it in their own words. Participants were shown 6 images modified in a variety of ways on a computer monitor and were asked to select the image that most closely represented their perception of their VF loss. Forced choice of an image best representing glaucomatous vision impairment. Participants had a range of VF defect severity: average HFA mean deviation was -8.7 dB (standard deviation [SD], 5.8 dB) and -10.5 dB (SD, 7.1 dB) in the right and left eyes, respectively. Thirteen patients (26%; 95% confidence interval [CI], 15%-40%) reported being completely unaware of their vision loss. None of the patients chose the images with a distinct black tunnel effect or black patches. Only 2 patients (4%; 95% CI, 0%-14%) chose the image with a tunnel effect with blurred edges. An image depicting blurred patches and another with missing patches was chosen by 54% (95% CI, 39%-68%) and 16% (95% CI, 7%-29%) of the patients, respectively. Content analysis of the transcripts from the recorded interviews indicated a frequent use of descriptors of visual symptoms associated with reported blur and missing features. Patients with glaucoma do not perceive their vision loss as a black tunnel effect or as black patches masking their field of view. These findings are important in the context of depicting the effects of glaucomatous vision loss and raising awareness for glaucoma detection. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Predicting progression of glaucoma from rates of frequency doubling technology perimetry change.
Meira-Freitas, Daniel; Tatham, Andrew J; Lisboa, Renato; Kuang, Tung-Mei; Zangwill, Linda M; Weinreb, Robert N; Girkin, Christopher A; Liebmann, Jeffrey M; Medeiros, Felipe A
2014-02-01
To evaluate the ability of longitudinal frequency doubling technology (FDT) to predict the development of glaucomatous visual field loss on standard automated perimetry (SAP) in glaucoma suspects. Prospective, observational cohort study. The study included 587 eyes of 367 patients with suspected glaucoma at baseline selected from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES). These eyes had an average of 6.7 ± 1.9 FDT tests during a mean follow-up time of 73.1 ± 28.0 months. Glaucoma suspects had intraocular pressure (IOP) >21 mmHg or an optic disc appearance suspicious of glaucoma. All patients had normal or nonrepeatable abnormal SAP at baseline. Humphrey Matrix FDT (Carl Zeiss Meditec, Inc, Dublin, CA) testing was performed within 6 months of SAP testing. The study end point was the development of 3 consecutive abnormal SAP test results. Joint longitudinal survival models were used to evaluate the ability of rates of FDT pattern standard deviation (PSD) change to predict the development of visual field loss on SAP, adjusting for confounding variables (baseline age, mean IOP, corneal thickness, and follow-up measurements of SAP PSD). The R(2) index was used to evaluate and compare the predictive abilities of the model containing longitudinal FDT PSD data with the model containing only baseline data. Sixty-three of 587 eyes (11%) developed SAP visual field loss during follow-up. The mean rate of FDT PSD change in eyes that developed SAP visual field loss was 0.07 dB/year versus 0.02 dB/year in those that did not (P < 0.001). Baseline FDT PSD and slopes of FDT PSD change were significantly predictive of progression, with hazard ratios of 1.11 per 0.1 dB higher (95% confidence interval [CI], 1.04-1.18; P = 0.002) and 4.40 per 0.1 dB/year faster (95% CI, 1.08-17.96; P = 0.04), respectively. The longitudinal model performed significantly better than the baseline model with an R(2) of 82% (95% CI, 74-89) versus 11% (95% CI, 2-24), respectively. Rates of FDT PSD change were highly predictive of the development of SAP visual field loss in glaucoma suspects. This finding suggests that longitudinal FDT evaluation may be useful for risk stratification of patients with suspected glaucoma. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
McIntyre, Scott E; Gugerty, Leo
2014-06-01
This field experiment takes a novel approach in applying methodologies and theories of visual search to the subject of conspicuity in automobile rear lighting. Traditional rear lighting research has not used the visual search paradigm in experimental design. It is our claim that the visual search design uniquely uncovers visual attention processes operating when drivers search the visual field that current designs fail to capture. This experiment is a validation and extension of previous simulator research on this same topic and demonstrates that detection of red automobile brake lamps will be improved if tail lamps are another color (in this test, amber) rather than the currently mandated red. Results indicate that when drivers miss brake lamp onset in low ambient light, RT and error are reduced in detecting the presence and absence of red brake lamps with multiple lead vehicles when tail lamps are not red compared to current rear lighting which mandates red tail lamps. This performance improvement is attributed to efficient visual processing that automatically segregates tail (amber) and brake (red) lamp colors into distractors and targets respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.
Horizontal visual search in a large field by patients with unilateral spatial neglect.
Nakatani, Ken; Notoya, Masako; Sunahara, Nobuyuki; Takahashi, Shusuke; Inoue, Katsumi
2013-06-01
In this study, we investigated the horizontal visual search ability and pattern of horizontal visual search in a large space performed by patients with unilateral spatial neglect (USN). Subjects included nine patients with right hemisphere damage caused by cerebrovascular disease showing left USN, nine patients with right hemisphere damage but no USN, and six healthy individuals with no history of brain damage who were age-matched to the groups with brain right hemisphere damage. The number of visual search tasks accomplished was recorded in the first experiment. Neck rotation angle was continuously measured during the task and quantitative data of the measurements were collected. There was a strong correlation between the number of visual search tasks accomplished and the total Behavioral Inattention Test Conventional Subtest (BITC) score in subjects with right hemisphere damage. In both USN and control groups, the head position during the visual search task showed a balanced bell-shaped distribution from the central point on the field to the left and right sides. Our results indicate that compensatory strategies, including cervical rotation, may improve visual search capability and achieve balance on the neglected side. Copyright © 2012 Elsevier Ltd. All rights reserved.
Disease course in patients with autosomal recessive retinitis pigmentosa due to the USH2A gene.
Sandberg, Michael A; Rosner, Bernard; Weigel-DiFranco, Carol; McGee, Terri L; Dryja, Thaddeus P; Berson, Eliot L
2008-12-01
To estimate the mean rates of ocular function loss in patients with autosomal recessive retinitis pigmentosa due to USH2A mutations. In 125 patients with USH2A mutations, longitudinal regression was used to estimate mean rates of change in Snellen visual acuity, Goldmann visual field area (V4e white test light), and 30-Hz (cone) full-field electroretinogram amplitude. These rates were compared with those of previously studied cohorts with dominant retinitis pigmentosa due to RHO mutations and with X-linked retinitis pigmentosa due to RPGR mutations. Rates of change in patients with the Cys759Phe mutation, the USH2A mutation associated with nonsyndromic disease, were compared with rates of change in patients with the Glu767fs mutation, the most common USH2A mutation associated with Usher syndrome type II (i.e., retinitis pigmentosa and hearing loss). Mean annual exponential rates of decline for the USH2A patients were 2.6% for visual acuity, 7.0% for visual field area, and 13.2% for electroretinogram amplitude. The rate of acuity loss fell between the corresponding rates for the RHO and RPGR patients, whereas the rates for field and ERG amplitude loss were faster than those for the RHO and RPGR patients. No significant differences were found for patients with the Cys759Phe mutation versus patients with the Glu767fs mutation. On average, USH2A patients lose visual acuity faster than RHO patients and slower than RPGR patients. USH2A patients lose visual field and cone electroretinogram amplitude faster than patients with RHO or RPGR mutations. Patients with a nonsyndromic USH2A mutation have the same retinal disease course as patients with syndromic USH2A disease.
NASA Technical Reports Server (NTRS)
Johns, Albert L.; Neiner, George; Bencic, Timothy J.; Flood, Joseph D.; Amuedo, Kurt C.
1990-01-01
A 9.2 percent scale STOVL hot gas ingestion model was tested in the NASA Lewis 9 x 15-foot Low-Speed Wind Tunnel. Flow visualization from the Phase 1 test program, which evaluated the hot ingestion phenomena and control techniques, is covered. The Phase 2 test program evaluated the hot gas ingestion phenomena at higher temperatures and used a laser sheet to investigate the flow field. Hot gas ingestion levels were measured for the several forward nozzle splay configurations and with flow control/life improvement devices (LIDs) which reduced the hot gas ingestion. The test was conducted at full scale nozzle pressure ratios and inlet Mach numbers. Results are presented over a range of nozzle pressure ratios at a 10 kn headwind velocity. The Phase 2 program was conducted at exhaust nozzle temperatures up to 1460 R and utilized a sheet laser system for flow visualization of the model flow field in and out of ground effects. The results reported are for nozzle exhaust temperatures up to 1160 R and contain the compressor face pressure and temperature distortions, the total pressure recovery, the inlet temperature rise, and the environmental effects of the hot gas. The environmental effects include the ground plane contours, the model airframe heating, and the location of the ground flow separation.
Difference in Visual Processing Assessed by Eye Vergence Movements
Solé Puig, Maria; Puigcerver, Laura; Aznar-Casanova, J. Antonio; Supèr, Hans
2013-01-01
Orienting visual attention is closely linked to the oculomotor system. For example, a shift of attention is usually followed by a saccadic eye movement and can be revealed by micro saccades. Recently we reported a novel role of another type of eye movement, namely eye vergence, in orienting visual attention. Shifts in visuospatial attention are characterized by the response modulation to a selected target. However, unlike (micro-) saccades, eye vergence movements do not carry spatial information (except for depth) and are thus not specific to a particular visual location. To further understand the role of eye vergence in visual attention, we tested subjects with different perceptual styles. Perceptual style refers to the characteristic way individuals perceive environmental stimuli, and is characterized by a spatial difference (local vs. global) in perceptual processing. We tested field independent (local; FI) and field dependent (global; FD) observers in a cue/no-cue task and a matching task. We found that FI observers responded faster and had stronger modulation in eye vergence in both tasks than FD subjects. The results may suggest that eye vergence modulation may relate to the trade-off between the size of spatial region covered by attention and the processing efficiency of sensory information. Alternatively, vergence modulation may have a role in the switch in cortical state to prepare the visual system for new incoming sensory information. In conclusion, vergence eye movements may be added to the growing list of functions of fixational eye movements in visual perception. However, further studies are needed to elucidate its role. PMID:24069140
Teodorescu, Kinneret; Bouchigny, Sylvain; Korman, Maria
2013-08-01
In this study, we explored the time course of haptic stiffness discrimination learning and how it was affected by two experimental factors, the addition of visual information and/or knowledge of results (KR) during training. Stiffness perception may integrate both haptic and visual modalities. However, in many tasks, the visual field is typically occluded, forcing stiffness perception to be dependent exclusively on haptic information. No studies to date addressed the time course of haptic stiffness perceptual learning. Using a virtual environment (VE) haptic interface and a two-alternative forced-choice discrimination task, the haptic stiffness discrimination ability of 48 participants was tested across 2 days. Each day included two haptic test blocks separated by a training block Additional visual information and/or KR were manipulated between participants during training blocks. Practice repetitions alone induced significant improvement in haptic stiffness discrimination. Between days, accuracy was slightly improved, but decision time performance was deteriorated. The addition of visual information and/or KR had only temporary effects on decision time, without affecting the time course of haptic discrimination learning. Learning in haptic stiffness discrimination appears to evolve through at least two distinctive phases: A single training session resulted in both immediate and latent learning. This learning was not affected by the training manipulations inspected. Training skills in VE in spaced sessions can be beneficial for tasks in which haptic perception is critical, such as surgery procedures, when the visual field is occluded. However, training protocols for such tasks should account for low impact of multisensory information and KR.
Zhang, Lei; Baldwin, Kevin; Munoz, Beatriz; Munro, Cynthia; Turano, Kathleen; Hassan, Shirin; Lyketsos, Constantine; Bandeen-Roche, Karen; West, Sheila K
2007-01-01
Concern for driving safety has prompted research into understanding factors related to performance. Brake reaction speed (BRS), the speed with which persons react to a sudden change in driving conditions, is a measure of performance. Our aim is to determine the visual, cognitive, and physical factors predicting BRS in a population sample of 1425 older drivers. The Maryland Department of Motor Vehicles roster of persons aged 67-87 and residing in Salisbury, MD, was used for recruitment of the study population. Procedures included the following: habitual, binocular visual acuity using ETDRS charts, contrast sensitivity using a Pelli-Robson chart, visual fields assessed with a 81-point screening Humphrey field at a single intensity threshold, and a questionnaire to ascertain medical conditions. Cognitive status was assessed using a standard battery of tests for attention, memory, visuo-spatial, and scanning. BRS was assessed using a computer-driven device that measured separately the initial reaction speed (IRS) (from light change to red until removing foot from accelerator) and physical response speed (PRS) (removing foot from accelerator to full brake depression). Five trial times were averaged, and time was converted to speed. The median brake reaction time varied from 384 to 5688 milliseconds. Age, gender, and cognition predicted total BRS, a non-informative result as there are two distinct parts to the task. Once separated, decrease in IRS was associated with low scores on cognitive factors and missing points on the visual field. A decrease in PRS was associated with having three or more physical complaints related to legs and feet, and poorer vision search. Vision was not related to PRS. We have demonstrated the importance of segregating the speeds for the two tasks involved in brake reaction. Only the IRS depends on vision. Persons in good physical condition may perform poorly on brake reaction tests if their vision or cognition is compromised.
Diekmann, Theresa; Schrems-Hoesl, Laura M; Mardin, Christian Y; Laemmer, Robert; Horn, Folkert K; Kruse, Friedrich E; Schrems, Wolfgang A
2018-02-01
The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. The study included 207 patients-75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC's nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC00494923; Erlangen Glaucoma Registry).
NASA Astrophysics Data System (ADS)
Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash
2017-10-01
Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.
Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash
2017-10-01
Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.
High-Performance 3D Articulated Robot Display
NASA Technical Reports Server (NTRS)
Powell, Mark W.; Torres, Recaredo J.; Mittman, David S.; Kurien, James A.; Abramyan, Lucy
2011-01-01
In the domain of telerobotic operations, the primary challenge facing the operator is to understand the state of the robotic platform. One key aspect of understanding the state is to visualize the physical location and configuration of the platform. As there is a wide variety of mobile robots, the requirements for visualizing their configurations vary diversely across different platforms. There can also be diversity in the mechanical mobility, such as wheeled, tracked, or legged mobility over surfaces. Adaptable 3D articulated robot visualization software can accommodate a wide variety of robotic platforms and environments. The visualization has been used for surface, aerial, space, and water robotic vehicle visualization during field testing. It has been used to enable operations of wheeled and legged surface vehicles, and can be readily adapted to facilitate other mechanical mobility solutions. The 3D visualization can render an articulated 3D model of a robotic platform for any environment. Given the model, the software receives real-time telemetry from the avionics system onboard the vehicle and animates the robot visualization to reflect the telemetered physical state. This is used to track the position and attitude in real time to monitor the progress of the vehicle as it traverses its environment. It is also used to monitor the state of any or all articulated elements of the vehicle, such as arms, legs, or control surfaces. The visualization can also render other sorts of telemetered states visually, such as stress or strains that are measured by the avionics. Such data can be used to color or annotate the virtual vehicle to indicate nominal or off-nominal states during operation. The visualization is also able to render the simulated environment where the vehicle is operating. For surface and aerial vehicles, it can render the terrain under the vehicle as the avionics sends it location information (GPS, odometry, or star tracking), and locate the vehicle over or on the terrain correctly. For long traverses over terrain, the visualization can stream in terrain piecewise in order to maintain the current area of interest for the operator without incurring unreasonable resource constraints on the computing platform. The visualization software is designed to run on laptops that can operate in field-testing environments without Internet access, which is a frequently encountered situation when testing in remote locations that simulate planetary environments such as Mars and other planetary bodies.
Clinical approach to optic neuropathies
Behbehani, Raed
2007-01-01
Optic neuropathy is a frequent cause of vision loss encountered by ophthalmologist. The diagnosis is made on clinical grounds. The history often points to the possible etiology of the optic neuropathy. A rapid onset is typical of demyelinating, inflammatory, ischemic and traumatic causes. A gradual course points to compressive, toxic/nutritional and hereditary causes. The classic clinical signs of optic neuropathy are visual field defect, dyschromatopsia, and abnormal papillary response. There are ancillary investigations that can support the diagnosis of optic neuropathy. Visual field testing by either manual kinetic or automated static perimetry is critical in the diagnosis. Neuro-imaging of the brain and orbit is essential in many optic neuropathies including demyelinating and compressive. Newer technologies in the evaluation of optic neuropathies include multifocal visual evoked potentials and optic coherence tomography. PMID:19668477
ERIC Educational Resources Information Center
Avance, Lyonel D.; Carr, Dorothy B.
Presented is the final report of a project to develop and field test audio and visual media to accompany developmentally sequenced activities appropriate for a physical education program for handicapped children from preschool through high school. Brief sections cover the following: the purposes and accomplishments of the project; the population…
A Unifying Motif for Spatial and Directional Surround Suppression.
Liu, Liu D; Miller, Kenneth D; Pack, Christopher C
2018-01-24
In the visual system, the response to a stimulus in a neuron's receptive field can be modulated by stimulus context, and the strength of these contextual influences vary with stimulus intensity. Recent work has shown how a theoretical model, the stabilized supralinear network (SSN), can account for such modulatory influences, using a small set of computational mechanisms. Although the predictions of the SSN have been confirmed in primary visual cortex (V1), its computational principles apply with equal validity to any cortical structure. We have therefore tested the generality of the SSN by examining modulatory influences in the middle temporal area (MT) of the macaque visual cortex, using electrophysiological recordings and pharmacological manipulations. We developed a novel stimulus that can be adjusted parametrically to be larger or smaller in the space of all possible motion directions. We found, as predicted by the SSN, that MT neurons integrate across motion directions for low-contrast stimuli, but that they exhibit suppression by the same stimuli when they are high in contrast. These results are analogous to those found in visual cortex when stimulus size is varied in the space domain. We further tested the mechanisms of inhibition using pharmacological manipulations of inhibitory efficacy. As predicted by the SSN, local manipulation of inhibitory strength altered firing rates, but did not change the strength of surround suppression. These results are consistent with the idea that the SSN can account for modulatory influences along different stimulus dimensions and in different cortical areas. SIGNIFICANCE STATEMENT Visual neurons are selective for specific stimulus features in a region of visual space known as the receptive field, but can be modulated by stimuli outside of the receptive field. The SSN model has been proposed to account for these and other modulatory influences, and tested in V1. As this model is not specific to any particular stimulus feature or brain region, we wondered whether similar modulatory influences might be observed for other stimulus dimensions and other regions. We tested for specific patterns of modulatory influences in the domain of motion direction, using electrophysiological recordings from MT. Our data confirm the predictions of the SSN in MT, suggesting that the SSN computations might be a generic feature of sensory cortex. Copyright © 2018 the authors 0270-6474/18/380989-11$15.00/0.
Costa, Thiago Leiros; Barboni, Mirella Telles Salgueiro; Moura, Ana Laura de Araújo; Bonci, Daniela Maria Oliveira; Gualtieri, Mirella; de Lima Silveira, Luiz Carlos; Ventura, Dora Fix
2012-01-01
The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6±6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24–2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann–Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9°, 15° and 21° of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = −0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = −0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created. PMID:22916187
What Do Patients With Glaucoma See? Visual Symptoms Reported by Patients With Glaucoma
Hu, Cindy X.; Zangalli, Camila; Hsieh, Michael; Gupta, Lalita; Williams, Alice L.; Richman, Jesse
2014-01-01
Abstract: Background: Vision loss from glaucoma has traditionally been described as loss of “peripheral vision.” In this prospective study, we aimed to improve our clinical understanding of the visual symptoms caused by glaucoma by asking patients specific detailed questions about how they see. Methods: Patients who were clinically diagnosed with various types and stages of glaucoma were included. All had a comprehensive ocular examination, including Octopus visual field testing. Patients were excluded if they had other ocular conditions that affected their vision, including cornea, lens or retina pathologies. Patients responded to an oral questionnaire about their visual symptoms. We investigated the visual symptoms described by patients with glaucoma and correlated the severity of visual field loss with visual symptoms reported. Results: Ninety-nine patients completed the questionnaire. Most patients (76%) were diagnosed with primary open-angle glaucoma. The most common symptoms reported by all patients, including patients with early or moderate glaucoma, were needing more light and blurry vision. Patients with a greater amount of field loss (Octopus mean defect >+9.4 dB) were more likely to report difficulty seeing objects to one or both sides, as if looking through dirty glasses and trouble differentiating boundaries and colors. Conclusions: Vision loss in patients with glaucoma is not as simple as the traditional view of loss of peripheral vision. Needing more light and blurry vision were the most common symptoms reported by patients with glaucoma. PMID:24992392
Spatial effects of shifting prisms on properties of posterior parietal cortex neurons
Karkhanis, Anushree N; Heider, Barbara; Silva, Fabian Muñoz; Siegel, Ralph M
2014-01-01
The posterior parietal cortex contains neurons that respond to visual stimulation and motor behaviour. The objective of the current study was to test short-term adaptation in neurons in macaque area 7a and the dorsal prelunate during visually guided reaching using Fresnel prisms that displaced the visual field. The visual perturbation shifted the eye position and created a mismatch between perceived and actual reach location. Two non-human primates were trained to reach to visual targets before, during and after prism exposure while fixating the reach target in different locations. They were required to reach to the physical location of the reach target and not the perceived, displaced location. While behavioural adaptation to the prisms occurred within a few trials, the majority of neurons responded to the distortion either with substantial changes in spatial eye position tuning or changes in overall firing rate. These changes persisted even after prism removal. The spatial changes were not correlated with the direction of induced prism shift. The transformation of gain fields between conditions was estimated by calculating the translation and rotation in Euler angles. Rotations and translations of the horizontal and vertical spatial components occurred in a systematic manner for the population of neurons suggesting that the posterior parietal cortex retains a constant representation of the visual field remapping between experimental conditions. PMID:24928956
NASA Technical Reports Server (NTRS)
Johns, Albert L.; Neiner, George; Bencic, Timothy J.; Flood, Joseph D.; Amuedo, Kurt C.; Strock, Thomas W.
1990-01-01
A 9.2 percent scale Short Takeoff and Vertical Landing (STOVL) hot gas ingestion model was designed and built by McDonnell Douglas Corporation (MCAIR) and tested in the Lewis Research Center 9 x 15 foot Low Speed Wind Tunnel (LSWT). Hot gas ingestion, the entrainment of heated engine exhaust into the inlet flow field, is a key development issure for advanced short takeoff and vertical landing aircraft. Flow visualization from the Phase 1 test program, which evaluated the hot ingestion phenomena and control techniques, is covered. The Phase 2 test program evaluated the hot gas ingestion phenomena at higher temperatures and used a laser sheet to investigate the flow field. Hot gas ingestion levels were measured for the several forward nozzle splay configurations and with flow control/life improvement devices (LIDs) which reduced the hot gas ingestion. The model support system had four degrees of freedom - pitch, roll, yaw, and vertical height variation. The model support system also provided heated high-pressure air for nozzle flow and a suction system exhaust for inlet flow. The test was conducted at full scale nozzle pressure ratios and inlet Mach numbers. Test and data analysis results from Phase 2 and flow visualization from both Phase 1 and 2 are documented. A description of the model and facility modifications is also provided. Headwind velocity was varied from 10 to 23 kn. Results are presented over a range of nozzle pressure ratios at a 10 kn headwind velocity. The Phase 2 program was conducted at exhaust nozzle temperatures up to 1460 R and utilized a sheet laser system for flow visualization of the model flow field in and out of ground effects. The results reported are for nozzle exhaust temperatures up to 1160 R. These results will contain the compressor face pressure and temperature distortions, the total pressure recovery, the inlet temperature rise, and the environmental effects of the hot gas. The environmental effects include the ground plane contours, the model airframe heating, and the location of the ground flow separation.
Basu, Anamitra; Mandal, Manas K
2004-07-01
The present study examined visual-field advantage as a function of presentation mode (unilateral, bilateral), stimulus structure (facial, lexical), and stimulus content (emotional, neutral). The experiment was conducted in a split visual-field paradigm using a JAVA-based computer program with recognition accuracy as the dependent measure. Unilaterally, rather than bilaterally, presented stimuli were significantly better recognized. Words were significantly better recognized than faces in the right visual-field; the difference was nonsignificant in the left visual-field. Emotional content elicited left visual-field and neutral content elicited right visual-field advantages. Copyright Taylor and Francis Inc.
Factors influencing self-reported vision-related activity limitation in the visually impaired.
Tabrett, Daryl R; Latham, Keziah
2011-07-15
The use of patient-reported outcome (PRO) measures to assess self-reported difficulty in visual activities is common in patients with impaired vision. This study determines the visual and psychosocial factors influencing patients' responses to self-report measures, to aid in understanding what is being measured. One hundred visually impaired participants completed the Activity Inventory (AI), which assesses self-reported, vision-related activity limitation (VRAL) in the task domains of reading, mobility, visual information, and visual motor tasks. Participants also completed clinical tests of visual function (distance visual acuity and near reading performance both with and without low vision aids [LVAs], contrast sensitivity, visual fields, and depth discrimination), and questionnaires assessing depressive symptoms, social support, adjustment to visual loss, and personality. Multiple regression analyses identified that an acuity measure (distance or near), and, to a lesser extent, near reading performance without LVAs, visual fields, and contrast sensitivity best explained self-reported VRAL (28%-50% variance explained). Significant psychosocial correlates were depression and adjustment, explaining an additional 6% to 19% unique variance. Dependent on task domain, the parameters assessed explained 59% to 71% of the variance in self-reported VRAL. Visual function, most notably acuity without LVAs, is the best predictor of self-reported VRAL assessed by the AI. Depression and adjustment to visual loss also significantly influence self-reported VRAL, largely independent of the severity of visual loss and most notably in the less vision-specific tasks. The results suggest that rehabilitation strategies addressing depression and adjustment could improve perceived visual disability.
Could visual neglect induce amblyopia?
Bier, J C; Vokaer, M; Fery, P; Garbusinski, J; Van Campenhoudt, G; Blecic, S A; Bartholomé, E J
2004-12-01
Oculomotor nerve disease is a common cause of diplopia. When strabismus is present, absence of diplopia has to induce the research of either uncovering of visual fields or monocular suppression, amblyopia or blindness. We describe the case of a 41-year-old woman presenting with right oculomotor paresis and left object-centred visual neglect due to a right fronto-parietal haemorrhage expanding to the right peri-mesencephalic cisterna caused by the rupture of a right middle cerebral artery aneurysm. She never complained of diplopia despite binocular vision and progressive recovery of strabismus, excluding uncovering of visual fields. Since all other causes were excluded in this case, we hypothesise that the absence of diplopia was due to the object-centred visual neglect. Partial internal right oculomotor paresis causes an ocular deviation in abduction; the image being perceived deviated contralaterally to the left. Thus, in our case, the neglect of the left image is equivalent to a right monocular functional blindness. However, bell cancellation test clearly worsened when assessed in left monocular vision confirming that eye patching can worsen attentional visual neglect. In conclusion, our case argues for the possibility of a functional monocular blindness induced by visual neglect. We think that in presence of strabismus, absence of diplopia should induce the search for hemispatial visual neglect when supratentorial lesions are suspected.
Field of dreamers and dreamed-up fields: functional and fake perimetry.
Thompson, J C; Kosmorsky, G S; Ellis, B D
1996-01-01
Hysterical and malingering patients can manifest visual field defects on perimetry (visual field testing), including defects suggestive of true visual pathway pathology. It has been shown that control subjects can easily imitate some pathologic defects with automated, computed perimetry. The authors sought to determine whether subjects could imitate the same pathologic defect with manual and automated perimetry. Six subjects posed as patients with neurologic problems. They had manual perimetry with both an experienced and inexperienced technician followed by automated perimetry. They were later interviewed about the methods of the technicians and the difficulty of the exercise. Four of six subjects easily imitated the assigned defects with both technicians on manual perimetry and with automated perimetry. These included quadrantic, altitudinal, hemianopic, and enlarged blind-spot defects. Two subjects who were assigned cecocentral and paracentral scotomas instead produced enlarged blind spots by manual perimetry and defects suggestive of chiasmal pathology by automated perimetry. Paradoxically, some subjects found that experienced technicians were easier to fool than inexperienced technicians because of the systematic way in which experienced technicians defined defects. With minimal coaching, some subjects can imitate visual fields with enlarged blind spots, quadrantic, hemianopic, and altitudinal defects with ease and reproducibility by both automated and manual perimetry. Cecocentral and paracentral scotomas are harder to imitate but may be mistaken as representing chiasmal pathology. Paradoxically, experienced technicians may not be better at detecting hysterical or malingering individuals.
Disease Course of Patients with Unilateral Pigmentary Retinopathy
Potsidis, Emorfily; Berson, Eliot L.
2011-01-01
Purpose. To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Methods. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Results. Mean annual rates of change for the affected eyes were −4.9% for visual field area, −4.7% for ERG amplitude to 0.5-Hz flashes, and −4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). Conclusions. The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity. PMID:21989720
Disease course of patients with unilateral pigmentary retinopathy.
Potsidis, Emorfily; Berson, Eliot L; Sandberg, Michael A
2011-11-29
To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Mean annual rates of change for the affected eyes were -4.9% for visual field area, -4.7% for ERG amplitude to 0.5-Hz flashes, and -4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥ 40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity.
[Possibilities of magnetotherapy in stabilization of visual function in patients with glaucoma].
Bisvas Shutanto Kumar; Listopadova, N A
1996-01-01
Courses of magnetotherapy (MT) using ATOS device with 33 mT magnetic field induction were administered to 31 patients (43 eyes) with primary open-angle glaucoma with compensated intraocular pressure. The operation mode was intermittent, with 1.0 to 1.5 Hz field rotation frequency by 6 radii. The procedure is administered to a patient in a sitting posture with magnetic inductor held before the eye. The duration of a session is 10 min, a course consists of 10 sessions. Untreated eyes (n = 15) of the same patients were examined for control. The patients were examined before and 4 to 5 months after MT course. Vision acuity improved by 0.16 diopters, on an average, in 29 eyes (96.7%) out of 30 with vision acuity below 1.0 before treatment. Visocontrastometry was carried out using Visokontrastometer-DT device with spatial frequency range from 0.4 to 19 cycle/degree (12 frequencies) and 125 x 125 monitor. The orientation of lattices was horizontal and vertical. The contrasts ranged from 0.03 to 0.9 (12 levels). MT brought about an improvement of spatial contrast sensitivity by at least 7 values of 12 levels in 22 (84.6%) out of 26 eyes and was unchanged in 4 eyes. Visual field was examined using Humphry automated analyzer. A 120-point threshold test was used. After a course of MT, visual field deficit decreased by at least 10% in 31 (72%) out of 43 eyes, increased in 3, and was unchanged in 9 eyes; on an average, visual field deficit decreased by 22.4% vs. the initial value. After 4 to 5 months the changes in the vision acuity and visual field deficit were negligible. In controls these parameters did not appreciably change over the entire follow-up period.
Practical landmarks for visual field disability in glaucoma.
Saunders, Luke J; Russell, Richard A; Crabb, David P
2012-09-01
To assess whether mean deviation (MD) from automated perimetry is related to the visual field (VF) component for legal fitness to drive (LFTD) in glaucoma patients. Monocular 24-2 VFs of 2604 patients with bilateral VF damage were retrospectively investigated. Integrated visual fields were calculated and used as a surrogate to assess LFTD according to current UK driving licence criteria. The better eye MD (BEMD), worse eye MD (WEMD) and a measure utilising MD of both eyes were compared, to assess respective diagnostic capabilities to predict LFTD (using the integrated visual field surrogate test as the gold standard) and a 'Probability of Failure' (PoF) for various defect levels was calculated. BEMD appears to be a good predictor of the VF component for a patient's LFTD (receiver operating characteristic area under the curve: 96.2%); MDs from both eyes offered no significant extra diagnostic power (area under the curve: 96.4%). PoF for BEMD thresholds of ≤-10 dB and ≤-14 dB were 70 (95% CI 66% to 74%) and 92% (87% to 95%), respectively. There is a strong relationship between BEMD and a patient's LFTD. PoF values for LFTD associated with readily available MD values provide practical landmarks for VF disability in glaucoma.
Visual function at 11 years of age in preterm-born children with and without fetal brain sparing.
Kok, Joke H; Prick, Liesbeth; Merckel, Elly; Everhard, Yolande; Verkerk, Gijs J Q; Scherjon, Sicco A
2007-06-01
We have demonstrated earlier an accelerated maturation of the visual evoked potential in the first year of life in preterm infants with antenatal brain sparing. We have now assessed visual functioning at 11 years of age in the same cohort and compared the groups with and without brain sparing. One hundred sixteen survivors included in a study on the outcome of preterm infants born at <33 weeks' gestation with and without fetal brain sparing and admitted to the NICU were followed extensively. Ninety-eight infants (85%) were again assessed at 11 years of age. Data were available for fetal Doppler measurements indicating brain sparing, neonatal cerebral ultrasound scanning, and developmental outcome in the first 5 years. Mean birth weight was 1303 g; mean gestational age was 29.8 weeks. The infants were divided into 2 groups with and without brain sparing. Visual functioning was estimated by measuring visual acuity, visual fields, eye position, and binocular function and by visual motor tests. Six percent of the children were found to have a visual acuity of <0.8, 12% had strabismus, and 14% to 46% showed abnormal results on the visual motor tests. No statistical differences were found between the 2 groups. However, children with severe cerebral ultrasound diagnoses in the neonatal period were found to have significantly more abnormalities on visual functioning and lower scores on visual motor tests than children without these morbidities. Children with fetal brain sparing do not demonstrate a different development of their visual functioning at late school age. However, an abnormal cerebral ultrasound in the neonatal period is associated with impaired visual function in later life.
Kunimatsu-Sanuki, Shiho; Iwase, Aiko; Araie, Makoto; Aoki, Yuki; Hara, Takeshi; Nakazawa, Toru; Yamaguchi, Takuhiro; Ono, Hiroshi; Sanuki, Tomoyuki; Itoh, Makoto
2015-01-01
Objective To assess the driving fitness of patients with glaucoma by identifying specific areas and degrees of visual field impairment that threaten safe driving. Design Case–control study. Setting, and participants This prospective study included 36 patients with advanced glaucoma, defined as Humphrey field analyzer (HFA; 24-2 SITA standard program) measurements of mean deviation in both eyes of worse than −12 dB, and 36 age-matched and driving exposure time-matched normal subjects. All participants underwent testing in a novel driving simulator (DS) system. Participants were recruited between September 2010 and January 2012. Main outcome measures The number of collisions with simulated hazards and braking response time in 14 DS scenarios was recorded. Monocular HFA 24-2 test results from both eyes were merged to calculate the binocular integrated visual field (IVF). The position of the IVF subfields in which the collision-involved patients had lower sensitivity than the collision-uninvolved patients was compared with the track of the hazard. The cut-off value to predict an elevated risk of collisions was determined, as were its sensitivity and specificity, with the area under the receiver operating characteristic (AUROC) curve. Results Patients with advanced glaucoma were involved in a significantly higher number of collisions in the DS than the age-matched and driving exposure time-matched normal subjects (119 vs 40, respectively, p<0.0001), especially in four specific DS scenarios. In these four scenarios, IVF sensitivity was significantly lower in the collision-involved patients than in the collision-uninvolved patients in subfields on or near the track of the simulated hazard (p<0.05). The subfields with the largest AUROC curve had values ranging from 0.72 to 0.91 and were located in the paracentral visual field just below the horizontal. Conclusions Our novel DS system effectively assessed visual impairment, showing that simulators may have future potential in educating patients. PMID:25724982
Hamel, Johanna; Kraft, Antje; Ohl, Sven; De Beukelaer, Sophie; Audebert, Heinrich J; Brandt, Stephan A
2012-09-18
Patients suffering from homonymous hemianopia after infarction of the posterior cerebral artery (PCA) report different degrees of constraint in daily life, despite similar visual deficits. We assume this could be due to variable development of compensatory strategies such as altered visual scanning behavior. Scanning compensatory therapy (SCT) is studied as part of the visual training after infarction next to vision restoration therapy. SCT consists of learning to make larger eye movements into the blind field enlarging the visual field of search, which has been proven to be the most useful strategy(1), not only in natural search tasks but also in mastering daily life activities(2). Nevertheless, in clinical routine it is difficult to identify individual levels and training effects of compensatory behavior, since it requires measurement of eye movements in a head unrestrained condition. Studies demonstrated that unrestrained head movements alter the visual exploratory behavior compared to a head-restrained laboratory condition(3). Martin et al.(4) and Hayhoe et al.(5) showed that behavior demonstrated in a laboratory setting cannot be assigned easily to a natural condition. Hence, our goal was to develop a study set-up which uncovers different compensatory oculomotor strategies quickly in a realistic testing situation: Patients are tested in the clinical environment in a driving simulator. SILAB software (Wuerzburg Institute for Traffic Sciences GmbH (WIVW)) was used to program driving scenarios of varying complexity and recording the driver's performance. The software was combined with a head mounted infrared video pupil tracker, recording head- and eye-movements (EyeSeeCam, University of Munich Hospital, Clinical Neurosciences). The positioning of the patient in the driving simulator and the positioning, adjustment and calibration of the camera is demonstrated. Typical performances of a patient with and without compensatory strategy and a healthy control are illustrated in this pilot study. Different oculomotor behaviors (frequency and amplitude of eye- and head-movements) are evaluated very quickly during the drive itself by dynamic overlay pictures indicating where the subjects gaze is located on the screen, and by analyzing the data. Compensatory gaze behavior in a patient leads to a driving performance comparable to a healthy control, while the performance of a patient without compensatory behavior is significantly worse. The data of eye- and head-movement-behavior as well as driving performance are discussed with respect to different oculomotor strategies and in a broader context with respect to possible training effects throughout the testing session and implications on rehabilitation potential.
Taylor, Lisa; Poland, Fiona; Harrison, Peter; Stephenson, Richard
2011-01-01
To evaluate a systematic treatment programme developed by the researcher that targeted aspects of visual functioning affected by visual field deficits following stroke. The study design was a non-equivalent control (conventional) group pretest-posttest quasi-experimental feasibility design, using multisite data collection methods at specified stages. The study was undertaken within three acute hospital settings as outpatient follow-up sessions. Individuals who had visual field deficits three months post stroke were studied. A treatment group received routine occupational therapy and an experimental group received, in addition, a systematic treatment programme. The treatment phase of both groups lasted six weeks. The Nottingham Adjustment Scale, a measure developed specifically for visual impairment, was used as the primary outcome measure. The change in Nottingham Adjustment Scale score was compared between the experimental (n = 7) and conventional (n = 8) treatment groups using the Wilcoxon signed ranks test. The result of Z = -2.028 (P = 0.043) showed that there was a statistically significant difference between the change in Nottingham Adjustment Scale score between both groups. The introduction of the systematic treatment programme resulted in a statistically significant change in the scores of the Nottingham Adjustment Scale.
Neuro-ophthalmologic evaluation, quality of life, and functional disability in patients with MS.
Garcia-Martin, Elena; Rodriguez-Mena, Diego; Herrero, Raquel; Almarcegui, Carmen; Dolz, Isabel; Martin, Jesus; Ara, Jose R; Larrosa, Jose M; Polo, Vicente; Fernández, Javier; Pablo, Luis E
2013-07-02
To evaluate correlations between longitudinal changes in neuro-ophthalmologic measures and quality of life (QOL) and disability in patients with multiple sclerosis (MS), using optical coherence tomography (OCT), visual evoked potentials (VEP), and visual field examination. Fifty-four patients with relapsing-remitting MS were enrolled in this study and underwent Multiple Sclerosis Quality of Life questionnaire (54 items) (MSQOL-54) and Expanded Disability Status Scale (EDSS) evaluation, as well as complete neuro-ophthalmologic examination including visual field testing and retinal nerve fiber layer (RNFL) measurements using Cirrus and Spectralis OCT and VEP. All patients were re-evaluated at 12, 24, and 36 months. Logistical regression was performed to analyze which measures, if any, could predict QOL. Overall, RNFL thickness results at the baseline evaluation were significantly different from those at 3 years (p ≤ 0.05), but there were no differences in functional measures (visual acuity, contrast sensitivity, color vision, visual field, and VEP). A reduced MSQOL-54 score was associated with an increase in EDSS score and a decrease in both functional and structural parameters. Patients with longer MS duration presented with a lower MSQOL-54 score (reduction in QOL). Patients with progressive axonal loss as seen in RNFL results had a lower QOL and more functional disability.
Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel
2015-12-01
To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.
Hasanov, Samir; Demirkilinc Biler, Elif; Acarer, Ahmet; Akkın, Cezmi; Colakoglu, Zafer; Uretmen, Onder
2018-05-09
To evaluate and follow-up of functional and morphological changes of the optic nerve and ocular structures prospectively in patients with early-stage Parkinson's disease. Nineteen patients with a diagnosis of early-stage Parkinson's disease and 19 age-matched healthy controls were included in the study. All participants were examined minimum three times at the intervals of at least 6 month following initial examination. Pattern visually evoked potentials (VEP), contrast sensitivity assessments at photopic conditions, color vision tests with Ishihara cards and full-field visual field tests were performed in addition to measurement of retinal nerve fiber layer (RNFL) thickness of four quadrants (top, bottom, nasal, temporal), central and mean macular thickness and macular volumes. Best corrected visual acuity was observed significantly lower in study group within all three examinations. Contrast sensitivity values of the patient group were significantly lower in all spatial frequencies. P100 wave latency of VEP was significantly longer, and amplitude was lower in patient group; however, significant deterioration was not observed during the follow-up. Although average peripapillary RNFL thickness was not significant between groups, RNFL thickness in the upper quadrant was thinner in the patient group. While there was no difference in terms of mean macular thickness and total macular volume values between the groups initially, a significant decrease occurred in the patient group during the follow-up. During the initial and follow-up process, a significant deterioration in visual field was observed in the patient group. Structural and functional disorders shown as electro-physiologically and morphologically exist in different parts of visual pathways in early-stage Parkinson's disease.
NASA Astrophysics Data System (ADS)
Vastaranta, Mikko; Kankare, Ville; Holopainen, Markus; Yu, Xiaowei; Hyyppä, Juha; Hyyppä, Hannu
2012-01-01
The two main approaches to deriving forest variables from laser-scanning data are the statistical area-based approach (ABA) and individual tree detection (ITD). With ITD it is feasible to acquire single tree information, as in field measurements. Here, ITD was used for measuring training data for the ABA. In addition to automatic ITD (ITD auto), we tested a combination of ITD auto and visual interpretation (ITD visual). ITD visual had two stages: in the first, ITD auto was carried out and in the second, the results of the ITD auto were visually corrected by interpreting three-dimensional laser point clouds. The field data comprised 509 circular plots ( r = 10 m) that were divided equally for testing and training. ITD-derived forest variables were used for training the ABA and the accuracies of the k-most similar neighbor ( k-MSN) imputations were evaluated and compared with the ABA trained with traditional measurements. The root-mean-squared error (RMSE) in the mean volume was 24.8%, 25.9%, and 27.2% with the ABA trained with field measurements, ITD auto, and ITD visual, respectively. When ITD methods were applied in acquiring training data, the mean volume, basal area, and basal area-weighted mean diameter were underestimated in the ABA by 2.7-9.2%. This project constituted a pilot study for using ITD measurements as training data for the ABA. Further studies are needed to reduce the bias and to determine the accuracy obtained in imputation of species-specific variables. The method could be applied in areas with sparse road networks or when the costs of fieldwork must be minimized.
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2013-05-01
To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.
Detection of longitudinal visual field progression in glaucoma using machine learning.
Yousefi, Siamak; Kiwaki, Taichi; Zheng, Yuhui; Suigara, Hiroki; Asaoka, Ryo; Murata, Hiroshi; Lemij, Hans; Yamanishi, Kenji
2018-06-16
Global indices of standard automated perimerty are insensitive to localized losses, while point-wise indices are sensitive but highly variable. Region-wise indices sit in between. This study introduces a machine-learning-based index for glaucoma progression detection that outperforms global, region-wise, and point-wise indices. Development and comparison of a prognostic index. Visual fields from 2085 eyes of 1214 subjects were used to identify glaucoma progression patterns using machine learning. Visual fields from 133 eyes of 71 glaucoma patients were collected 10 times over 10 weeks to provide a no-change, test-retest dataset. The parameters of all methods were identified using visual field sequences in the test-retest dataset to meet fixed 95% specificity. An independent dataset of 270 eyes of 136 glaucoma patients and survival analysis were utilized to compare methods. The time to detect progression in 25% of the eyes in the longitudinal dataset using global mean deviation (MD) was 5.2 years (95% confidence interval, 4.1 - 6.5 years); 4.5 years (4.0 - 5.5) using region-wise, 3.9 years (3.5 - 4.6) using point-wise, and 3.5 years (3.1 - 4.0) using machine learning analysis. The time until 25% of eyes showed subsequently confirmed progression after two additional visits were included were 6.6 years (5.6 - 7.4 years), 5.7 years (4.8 - 6.7), 5.6 years (4.7 - 6.5), and 5.1 years (4.5 - 6.0) for global, region-wise, point-wise, and machine learning analyses, respectively. Machine learning analysis detects progressing eyes earlier than other methods consistently, with or without confirmation visits. In particular, machine learning detects more slowly progressing eyes than other methods. Copyright © 2018 Elsevier Inc. All rights reserved.
Data Visualization Saliency Model: A Tool for Evaluating Abstract Data Visualizations
Matzen, Laura E.; Haass, Michael J.; Divis, Kristin M.; ...
2017-08-29
Evaluating the effectiveness of data visualizations is a challenging undertaking and often relies on one-off studies that test a visualization in the context of one specific task. Researchers across the fields of data science, visualization, and human-computer interaction are calling for foundational tools and principles that could be applied to assessing the effectiveness of data visualizations in a more rapid and generalizable manner. One possibility for such a tool is a model of visual saliency for data visualizations. Visual saliency models are typically based on the properties of the human visual cortex and predict which areas of a scene havemore » visual features (e.g. color, luminance, edges) that are likely to draw a viewer's attention. While these models can accurately predict where viewers will look in a natural scene, they typically do not perform well for abstract data visualizations. In this paper, we discuss the reasons for the poor performance of existing saliency models when applied to data visualizations. We introduce the Data Visualization Saliency (DVS) model, a saliency model tailored to address some of these weaknesses, and we test the performance of the DVS model and existing saliency models by comparing the saliency maps produced by the models to eye tracking data obtained from human viewers. In conclusion, we describe how modified saliency models could be used as general tools for assessing the effectiveness of visualizations, including the strengths and weaknesses of this approach.« less
Data Visualization Saliency Model: A Tool for Evaluating Abstract Data Visualizations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzen, Laura E.; Haass, Michael J.; Divis, Kristin M.
Evaluating the effectiveness of data visualizations is a challenging undertaking and often relies on one-off studies that test a visualization in the context of one specific task. Researchers across the fields of data science, visualization, and human-computer interaction are calling for foundational tools and principles that could be applied to assessing the effectiveness of data visualizations in a more rapid and generalizable manner. One possibility for such a tool is a model of visual saliency for data visualizations. Visual saliency models are typically based on the properties of the human visual cortex and predict which areas of a scene havemore » visual features (e.g. color, luminance, edges) that are likely to draw a viewer's attention. While these models can accurately predict where viewers will look in a natural scene, they typically do not perform well for abstract data visualizations. In this paper, we discuss the reasons for the poor performance of existing saliency models when applied to data visualizations. We introduce the Data Visualization Saliency (DVS) model, a saliency model tailored to address some of these weaknesses, and we test the performance of the DVS model and existing saliency models by comparing the saliency maps produced by the models to eye tracking data obtained from human viewers. In conclusion, we describe how modified saliency models could be used as general tools for assessing the effectiveness of visualizations, including the strengths and weaknesses of this approach.« less
Water tunnel flow visualization using a laser
NASA Technical Reports Server (NTRS)
Beckner, C.; Curry, R. E.
1985-01-01
Laser systems for flow visualization in water tunnels (similar to the vapor screen technique used in wind tunnels) can provide two-dimensional cross-sectional views of complex flow fields. This parametric study documents the practical application of the laser-enhanced visualization (LEV) technique to water tunnel testing. Aspects of the study include laser power levels, flow seeding (using flourescent dyes and embedded particulates), model preparation, and photographic techniques. The results of this study are discussed to provide potential users with basic information to aid in the design and setup of an LEV system.
Lee, Seungjoo; Hong, Seok Ho; Cho, Young Hyun; Kim, Jeong Hoon; Kim, Chang Jin
2016-05-01
Tuberculum sellae meningiomas (TSM) arise from the dura mater of tuberculum sellae, limbus sphenoidale, and chiasmatic sulcus and cause asymmetric visual disturbances. In this study, we analyzed the laterality of the origin of TSM and discussed its clinical implications on immediate and long-term visual outcomes. Between 1994 and 2013, TSM was diagnosed in 100 patients after microsurgical resection. The medical records, radiologic features, and operative findings were retrospectively reviewed and analyzed in these patients. Visual disturbances were evident in 95 patients (95%) after neuro-ophthalmologic testing. Among them, 89 patients (89%) showed marked asymmetric visual field defect, and 6 patients (6%) had relatively symmetric visual field defect. On intraoperative inspection, the origin of TSM was at the one lateral end portion of the tuberculum sellae in 85 patients (85%). In 15 patients (15%), the TSM originated from the midline region, including the central portion of the tuberculum sellae (n = 13) and diaphragm sellae (n = 2). Optic canal involvement was observed in 73 patients (73%). Preexisting visual field defects were improved in 70 patients (70%), were stationary in 25 patients (25%), and aggravated in 5 patients (5%) during postoperative follow-up (mean 58 months, 24∼122 months). The preoperative symptom duration, the laterality of the origin of TSM, and optic disc atrophy were associated with long-term poor visual outcomes. Most TSMs that originated from the dura of one lateral end portion of the tuberculum sellae correlated with asymmetric visual symptoms and poor visual outcomes. This microsurgical feature should be considered in the planning of optimal surgical strategy to achieve favorable outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
Patel, Dipesh E; Cumberland, Phillippa M; Walters, Bronwen C; Russell-Eggitt, Isabelle; Brookes, John; Papadopoulos, Maria; Khaw, Peng Tee; Viswanathan, Ananth C; Garway-Heath, David; Cortina-Borja, Mario; Rahi, Jugnoo S
2018-02-01
There is limited evidence to support the development of guidance for visual field testing in children with glaucoma. To compare different static and combined static/kinetic perimetry approaches in children with glaucoma. Cross-sectional, observational study recruiting children prospectively between May 2013 and June 2015 at 2 tertiary specialist pediatric ophthalmology centers in London, England (Moorfields Eye Hospital and Great Ormond Street Hospital). The study included 65 children aged 5 to 15 years with glaucoma (108 affected eyes). A comparison of test quality and outcomes for static and combined static/kinetic techniques, with respect to ability to quantify glaucomatous loss. Children performed perimetric assessments using Humphrey static (Swedish Interactive Thresholding Algorithm 24-2 FAST) and Octopus combined static tendency-oriented perimetry/kinetic perimetry (isopter V4e, III4e, or I4e) in a single sitting, using standardized clinical protocols, administered by a single examiner. Information was collected about test duration, completion, and quality (using automated reliability indices and our qualitative Examiner-Based Assessment of Reliability score). Perimetry outputs were scored using the Aulhorn and Karmeyer classification. One affected eye in 19 participants was retested with Swedish Interactive Thresholding Algorithm 24-2 FAST and 24-2 standard algorithms. Sixty-five children (33 girls [50.8%]), with a median age of 12 years (interquartile range, 9-14 years), were tested. Test quality (Examiner-Based Assessment of Reliability score) improved with increasing age for both Humphrey and Octopus strategies and were equivalent in children older than 10 years (McNemar test, χ2 = 0.33; P = .56), but better-quality tests with Humphrey perimetry were achieved in younger children (McNemar test, χ2 = 4.0; P = .05). Octopus and Humphrey static MD values worse than or equal to -6 dB showed disagreement (Bland-Altman, mean difference, -0.70; limit of agreement, -7.74 to 6.35) but were comparable when greater than this threshold (mean difference, -0.03; limit of agreement, -2.33 to 2.27). Visual field classification scores for static perimetry tests showed substantial agreement (linearly weighted κ, 0.79; 95% CI, 0.65-0.93), although 25 of 80 (31%) were graded with a more severe defect for Octopus static perimetry. Of the 7 severe cases of visual field loss (grade 5), 5 had lower kinetic than static classification scores. A simple static perimetry approach potentially yields high-quality results in children younger than 10 years. For children older than 10 years, without penalizing quality, the addition of kinetic perimetry enabled measurement of far-peripheral sensitivity, which is particularly useful in children with severe visual field restriction.
O'Connell, Caitlin; Ho, Leon C; Murphy, Matthew C; Conner, Ian P; Wollstein, Gadi; Cham, Rakie; Chan, Kevin C
2016-11-09
Human visual performance has been observed to show superiority in localized regions of the visual field across many classes of stimuli. However, the underlying neural mechanisms remain unclear. This study aims to determine whether the visual information processing in the human brain is dependent on the location of stimuli in the visual field and the corresponding neuroarchitecture using blood-oxygenation-level-dependent functional MRI (fMRI) and diffusion kurtosis MRI, respectively, in 15 healthy individuals at 3 T. In fMRI, visual stimulation to the lower hemifield showed stronger brain responses and larger brain activation volumes than the upper hemifield, indicative of the differential sensitivity of the human brain across the visual field. In diffusion kurtosis MRI, the brain regions mapping to the lower visual field showed higher mean kurtosis, but not fractional anisotropy or mean diffusivity compared with the upper visual field. These results suggested the different distributions of microstructural organization across visual field brain representations. There was also a strong positive relationship between diffusion kurtosis and fMRI responses in the lower field brain representations. In summary, this study suggested the structural and functional brain involvements in the asymmetry of visual field responses in humans, and is important to the neurophysiological and psychological understanding of human visual information processing.
Functional visual fields: relationship of visual field areas to self-reported function.
Subhi, Hikmat; Latham, Keziah; Myint, Joy; Crossland, Michael D
2017-07-01
The aim of this study is to relate areas of the visual field to functional difficulties to inform the development of a binocular visual field assessment that can reflect the functional consequences of visual field loss. Fifty-two participants with peripheral visual field loss undertook binocular assessment of visual fields using the 30-2 and 60-4 SITA Fast programs on the Humphrey Field Analyser, and mean thresholds were derived. Binocular visual acuity, contrast sensitivity and near reading performance were also determined. Self-reported overall and mobility function were assessed using the Dutch ICF Activity Inventory. Greater visual field loss (0-60°) was associated with worse self-reported function both overall (R 2 = 0.50; p < 0.0001), and for mobility (R 2 = 0.64; p < 0.0001). Central (0-30°) and peripheral (30-60°) visual field areas were similarly related to mobility function (R 2 = 0.61, p < 0.0001 and R 2 = 0.63, p < 0.0001 respectively), although the peripheral (30-60°) visual field was the best predictor of mobility self-reported function in multiple regression analyses. Superior and inferior visual field areas related similarly to mobility function (R 2 = 0.56, p < 0.0001 and R 2 = 0.67, p < 0.0001 respectively). The inferior field was found to be the best predictor of mobility function in multiple regression analysis. Mean threshold of the binocular visual field to 60° eccentricity is a good predictor of self-reported function overall, and particularly of mobility function. Both the central (0-30°) and peripheral (30-60°) mean threshold are good predictors of self-reported function, but the peripheral (30-0°) field is a slightly better predictor of mobility function, and should not be ignored when considering functional consequences of field loss. The inferior visual field is a slightly stronger predictor of perceived overall and mobility function than the superior field. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Coleman, Anne Louise
2007-01-01
Purpose To determine the sources of binocular visual field loss most strongly associated with falls in a cohort of older women. Methods In the Study of Osteoporotic Fractures, women with severe binocular visual field loss had an increased risk of two or more falls during the 12 months following the eye examination. The lens and fundus photographs of the 422 women with severe binocular visual field loss, plus a random sample of 141 white women with no, mild, or moderate binocular visual field loss—47 white women with no binocular visual field loss, 46 white women with mild binocular visual field loss, and 48 white women with moderate binocular visual field loss —were evaluated for lens opacities, glaucomatous optic nerve damage, age-related macular degeneration, and diabetic retinopathy. Results Eighty-four percent of the women with severe binocular visual field loss had ocular disease in one or both eyes. Bilateral cataracts and glaucomatous optic nerve damage were the most common sources of this severe binocular visual field loss. Approximately 15.2% of women had no evidence of lens opacities, glaucomatous optic nerve damage, age-related macular degeneration, or diabetic retinopathy. Conclusion Severe binocular visual field loss due primarily to cataracts, glaucoma, and age-related macular degeneration explains 33.3% of the falls among women who fell frequently. Because binocular visual field loss may be treatable and/or preventable, screening programs for binocular visual field loss and subsequent referral for intervention and treatment are recommended as a strategy for preventing falls among the elderly. PMID:18427619
Grewal, Navnit Kaur; Mosdøl, Annhild; Aunan, Marte Bergsund; Monsen, Carina; Torheim, Liv Elin
2014-01-01
The aim of this study was to develop, test, and evaluate a 24-h recall procedure to assess the dietary intake of toddlers of Somali- and Iraqi-born mothers living in Norway. A protocol for a 24-h multiple-pass recall procedure, registration forms, and visual tools (a picture library for food identification and portion size estimation) was developed and tested in 12 mothers from Somalia and Iraq with children aged 10–21 months. Five female field workers were recruited and trained to conduct the interviews. Evaluation data for the 24-h recall procedure were collected from both the mothers and the field workers. Nutrient intake was calculated using a Norwegian dietary calculation system. Each child’s estimated energy intake was compared with its estimated energy requirement. Both the mothers and the field workers found the method feasible and the visual tools useful. The estimated energy intake corresponded well with the estimated energy requirement for most of the children (within mean ± 2 SD, except for three). The pilot study identified the need for additional foods in the picture library and some crucial aspects in training and supervising the field workers to reduce sources of error in the data collection. PMID:24949548
Bellis, Teri James; Ross, Jody
2011-09-01
It has been suggested that, in order to validate a diagnosis of (C)APD (central auditory processing disorder), testing using direct cross-modal analogs should be performed to demonstrate that deficits exist solely or primarily in the auditory modality (McFarland and Cacace, 1995; Cacace and McFarland, 2005). This modality-specific viewpoint is controversial and not universally accepted (American Speech-Language-Hearing Association [ASHA], 2005; Musiek et al, 2005). Further, no such analogs have been developed to date, and neither the feasibility of such testing in normally functioning individuals nor the concurrent validity of cross-modal analogs has been established. The purpose of this study was to investigate the feasibility of cross-modal testing by examining the performance of normal adults and children on four tests of central auditory function and their corresponding visual analogs. In addition, this study investigated the degree to which concurrent validity of auditory and visual versions of these tests could be demonstrated. An experimental repeated measures design was employed. Participants consisted of two groups (adults, n=10; children, n=10) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of auditory/otologic, language, learning, neurologic, or related disorders. Visual analogs of four tests in common clinical use for the diagnosis of (C)APD were developed (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; Duration Patterns [Pinheiro and Musiek, 1985]; and the Random Gap Detection Test [RGDT; Keith, 2000]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANOVAs (analyses of variance) were used to examine effects of group, modality, and laterality (for the Dichotic/Dichoptic Digits tests) or response condition (for the auditory and visual Frequency Patterns and Duration Patterns tests). Pearson product-moment correlations were used to investigate relationships between auditory and visual performance. Adults performed significantly better than children on the Dichotic/Dichoptic Digits tests. Results also revealed a significant effect of modality, with auditory better than visual, and a significant modality×laterality interaction, with a right-ear advantage seen for the auditory task and a left-visual-field advantage seen for the visual task. For the Frequency Patterns test and its visual analog, results revealed a significant modality×response condition interaction, with humming better than labeling for the auditory version but the reversed effect for the visual version. For Duration Patterns testing, visual performance was significantly poorer than auditory performance. Due to poor test-retest reliability and ceiling effects for the auditory and visual gap-detection tasks, analyses could not be performed. No cross-modal correlations were observed for any test. Results demonstrated that cross-modal testing is at least feasible using easily accessible computer hardware and software. The lack of any cross-modal correlations suggests independent processing mechanisms for auditory and visual versions of each task. Examination of performance in individuals with central auditory and pan-sensory disorders is needed to determine the utility of cross-modal analogs in the differential diagnosis of (C)APD. American Academy of Audiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strons, Philip; Bailey, James L.
Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measuredmore » relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.« less
Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel
NASA Technical Reports Server (NTRS)
McQuillen, John B.; Chao, David F.; Hall, Nancy R.; Zhang, Nengli
2012-01-01
A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.
Multifocal visual evoked potentials for early glaucoma detection.
Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W
2012-07-01
To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.
Flow visualization study of the HiMAT RPRV
NASA Technical Reports Server (NTRS)
Lorincz, D. J.
1980-01-01
Water tunnel studies were performed to qualitatively define the flow field of the highly maneuverable aircraft technology remotely piloted research vehicle (HiMAT RPRV). Particular emphasis was placed on defining the vortex flows generated at high angles of attack. The flow visualization tests were conducted in the Northrop water tunnel using a 1/15 scale model of the HiMAT RPRV. Flow visualization photographs were obtained for angles of attack up to 40 deg and sideslip angles up to 5 deg. The HiMAT model was investigated in detail to determine the canard and wing vortex flow field development, vortex paths, and vortex breakdown characteristics as a function of angle of attack and sideslip. The presence of the canard caused the wing vortex to form further outboard and delayed the breakdown of the wing vortex to higher angles of attack. An increase in leading edge camber of the maneuver configuration delayed both the formation and the breakdown of the wing and canard vortices. Additional tests showed that the canard vortex was sensitive to variations in inlet mass flow ratio and canard flap deflection angle.
Aphasic Patients Exhibit a Reversal of Hemispheric Asymmetries in Categorical Color Discrimination
Paluy, Yulia; Gilbert, Aubrey L.; Baldo, Juliana V.; Dronkers, Nina F.; Ivry, Richard B.
2010-01-01
Patients with left hemisphere (LH) or right hemisphere (RH) brain injury due to stroke were tested on a speeded, color discrimination task in which two factors were manipulated: 1) the categorical relationship between the target and the distracters and 2) the visual field in which the target was presented. Similar to controls, the RH patients were faster in detecting targets in the right visual field when the target and distracters had different color names compared to when their names were the same. This effect was absent in the LH patients, consistent with the hypothesis that injury to the left hemisphere handicaps the automatic activation of lexical codes. Moreover, the LH patients showed a reversed effect, such that the advantage of different target-distracter names was now evident for targets in the left visual field. This reversal may suggest a reorganization of the color lexicon in the right hemisphere following left hemisphere brain injury and/or the unmasking of a heightened right hemisphere sensitivity to color categories. PMID:21216454
Visual motion perception predicts driving hazard perception ability.
Lacherez, Philippe; Au, Sandra; Wood, Joanne M
2014-02-01
To examine the basis of previous findings of an association between indices of driving safety and visual motion sensitivity and to examine whether this association could be explained by low-level changes in visual function. A total of 36 visually normal participants (aged 19-80 years) completed a battery of standard vision tests including visual acuity, contrast sensitivity and automated visual fields and two tests of motion perception including sensitivity for movement of a drifting Gabor stimulus and sensitivity for displacement in a random dot kinematogram (Dmin ). Participants also completed a hazard perception test (HPT), which measured participants' response times to hazards embedded in video recordings of real-world driving, which has been shown to be linked to crash risk. Dmin for the random dot stimulus ranged from -0.88 to -0.12 log minutes of arc, and the minimum drift rate for the Gabor stimulus ranged from 0.01 to 0.35 cycles per second. Both measures of motion sensitivity significantly predicted response times on the HPT. In addition, while the relationship involving the HPT and motion sensitivity for the random dot kinematogram was partially explained by the other visual function measures, the relationship with sensitivity for detection of the drifting Gabor stimulus remained significant even after controlling for these variables. These findings suggest that motion perception plays an important role in the visual perception of driving-relevant hazards independent of other areas of visual function and should be further explored as a predictive test of driving safety. Future research should explore the causes of reduced motion perception to develop better interventions to improve road safety. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Real time visualization of dynamic magnetic fields with a nanomagnetic ferrolens
NASA Astrophysics Data System (ADS)
Markoulakis, Emmanouil; Rigakis, Iraklis; Chatzakis, John; Konstantaras, Antonios; Antonidakis, Emmanuel
2018-04-01
Due to advancements in nanomagnetism and latest nanomagnetic materials and devices, a new potential field has been opened up for research and applications which was not possible before. We herein propose a new research field and application for nanomagnetism for the visualization of dynamic magnetic fields in real-time. In short, Nano Magnetic Vision. A new methodology, technique and apparatus were invented and prototyped in order to demonstrate and test this new application. As an application example the visualization of the dynamic magnetic field on a transmitting antenna was chosen. Never seen before high-resolution, photos and real-time color video revealing the actual dynamic magnetic field inside a transmitting radio antenna rod has been captured for the first time. The antenna rod is fed with six hundred volts, orthogonal pulses. This unipolar signal is in the very low frequency (i.e. VLF) range. The signal combined with an extremely short electrical length of the rod, ensures the generation of a relatively strong fluctuating magnetic field, analogue to the signal transmitted, along and inside the antenna. This field is induced into a ferrolens and becomes visible in real-time within the normal human eyes frequency spectrum. The name we have given to the new observation apparatus is, SPIONs Superparamagnetic Ferrolens Microscope (SSFM), a powerful passive scientific observation tool with many other potential applications in the near future.
Wall, Michael; Zamba, Gideon K D; Artes, Paul H
2018-01-01
It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on "censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher.
The SCHEIE Visual Field Grading System
Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan
2017-01-01
Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621
Corticosteroid therapy in patients with non-arteritic anterior ischemic optic neuropathy.
Vidović, Tomislav; Cerovski, Branimir; Perić, Sanja; Kordić, Rajko; Mrazovac, Danijela
2015-03-01
Non-arteritic anterior ischemic optic neuropathy is one of the most common conditions affecting the optic nerve in the elderly. It may lead to severe visual loss. Typical symptoms are painless impairment of visual function accompanied by relative afferent pupillary defect, edema of the optic disc and visual field defects. Aim is to present 38 patients with nonarteritic anterior ischemic optic neuropathy who were treated with corticosteroid therapy. This prospective study involved 38 patients, 20 men and 18 women aged 60-75 years who were treated with corticosteroid therapy. The study included patients with visual acuity in the affected eye from 0.1 to 0.8 according to Snellen. Every patient underwent clinical examination, the Octopus 900 perimetry in G program, laboratory testing, while the compressive optic neuropathy was rule out with MSCT of the brain and orbits. The most common forms of visual field defect are altitudinal defect and diffuse depression. Corticosteroid therapy led to recovery in 65% of patient, in 30% of patients did not change, while the deterioration occurred in 5% of patients.
Retinitis Pigmentosa Sine Pigmento Mimicking a Chiasm Disease.
Pellegrini, Francesco; Prosdocimo, Giovanni; Romano, Francesco; Interlandi, Emanuela
2017-08-01
A 75-year-old woman presented to her ophthalmologist complaining of visual loss for several years. The ophthalmic examination was remarkable for a bitemporal visual field defect. Magnetic resonance imaging (MRI) scan of the brain was normal without evidence of chiasm compression. Neuro-ophthalmic examination was consistent with a retinal rather than a chiasmal disease. Retinal multimodal imaging helped in the correct diagnosis of retinitis pigmentosa, later confirmed by genetic testing.
Simmering, Vanessa R.; Miller, Hilary E.; Bohache, Kevin
2015-01-01
Research on visual working memory has focused on characterizing the nature of capacity limits as “slots” or “resources” based almost exclusively on adults’ performance with little consideration for developmental change. Here we argue that understanding how visual working memory develops can shed new light onto the nature of representations. We present an alternative model, the Dynamic Field Theory (DFT), which can capture effects that have been previously attributed either to “slot” or “resource” explanations. The DFT includes a specific developmental mechanism to account for improvements in both resolution and capacity of visual working memory throughout childhood. Here we show how development in the DFT can account for different capacity estimates across feature types (i.e., color and shape). The current paper tests this account by comparing children’s (3, 5, and 7 years of age) performance across different feature types. Results showed that capacity for colors increased faster over development than capacity for shapes. A second experiment confirmed this difference across feature types within subjects, but also showed that the difference can be attenuated by testing memory for less-familiar colors. Model simulations demonstrate how developmental changes in connectivity within the model—purportedly arising through experience—can capture differences across feature types. PMID:25737253
Simmering, Vanessa R; Miller, Hilary E; Bohache, Kevin
2015-05-01
Research on visual working memory has focused on characterizing the nature of capacity limits as "slots" or "resources" based almost exclusively on adults' performance with little consideration for developmental change. Here we argue that understanding how visual working memory develops can shed new light onto the nature of representations. We present an alternative model, the Dynamic Field Theory (DFT), which can capture effects that have been previously attributed either to "slot" or "resource" explanations. The DFT includes a specific developmental mechanism to account for improvements in both resolution and capacity of visual working memory throughout childhood. Here we show how development in the DFT can account for different capacity estimates across feature types (i.e., color and shape). The current paper tests this account by comparing children's (3, 5, and 7 years of age) performance across different feature types. Results showed that capacity for colors increased faster over development than capacity for shapes. A second experiment confirmed this difference across feature types within subjects, but also showed that the difference can be attenuated by testing memory for less familiar colors. Model simulations demonstrate how developmental changes in connectivity within the model-purportedly arising through experience-can capture differences across feature types.
Ciuffreda, Kenneth J; Yadav, Naveen K; Ludlam, Diana P
2013-01-01
The purpose of the experiment was to assess the effect of binasal occlusion (BNO) on the visually-evoked potential (VEP) in visually-normal (VN) individuals and in those with mild traumatic brain injury (mTBI) for whom BNO frequently reduces their primary symptoms related to abnormally-increased visual motion sensitivity (VMS). Subjects were comprised of asymptomatic VN adults (n = 10) and individuals with mTBI (n = 10) having the symptom of VMS. Conventional full-field VEP testing was employed under two conditions: without BNO and with opaque BNO which blocked regions on either side of the VEP test stimulus. Subjective impressions were also assessed. In VN, the mean VEP amplitude decreased significantly with BNO in all subjects. In contrast, in mTBI, the mean VEP amplitude increased significantly with BNO in all subjects. Latency was normal and unaffected in all cases. Repeat VEP testing in three subjects from each group revealed similar test-re-test findings. Visuomotor activities improved, with reduced symptoms, with BNO in the mTBI group. It is speculated that individuals with mTBI habitually attempt to suppress visual information in the near retinal periphery to reduce their abnormal VMS, with addition of the BNO negating the suppressive influence and thus producing a widespread disinhibition effect and resultant increase in VEP amplitude.
Design of a reading test for low-vision image warping
NASA Astrophysics Data System (ADS)
Loshin, David S.; Wensveen, Janice; Juday, Richard D.; Barton, R. Shane
1993-08-01
NASA and the University of Houston College of Optometry are examining the efficacy of image warping as a possible prosthesis for at least two forms of low vision -- maculopathy and retinitis pigmentosa. Before incurring the expense of reducing the concept to practice, one would wish to have confidence that a worthwhile improvement in visual function would result. NASA's Programmable Remapper (PR) can warp an input image onto arbitrary geometric coordinate systems at full video rate, and it has recently been upgraded to accept computer- generated video text. We have integrated the Remapper with an SRI eye tracker to simulate visual malfunction in normal observers. A reading performance test has been developed to determine if the proposed warpings yield an increase in visual function; i.e., reading speed. We describe the preliminary experimental results of this reading test with a simulated central field defect with and without remapped images.
Design of a reading test for low vision image warping
NASA Technical Reports Server (NTRS)
Loshin, David S.; Wensveen, Janice; Juday, Richard D.; Barton, R. S.
1993-01-01
NASA and the University of Houston College of Optometry are examining the efficacy of image warping as a possible prosthesis for at least two forms of low vision - maculopathy and retinitis pigmentosa. Before incurring the expense of reducing the concept to practice, one would wish to have confidence that a worthwhile improvement in visual function would result. NASA's Programmable Remapper (PR) can warp an input image onto arbitrary geometric coordinate systems at full video rate, and it has recently been upgraded to accept computer-generated video text. We have integrated the Remapper with an SRI eye tracker to simulate visual malfunction in normal observers. A reading performance test has been developed to determine if the proposed warpings yield an increase in visual function; i.e., reading speed. We will describe the preliminary experimental results of this reading test with a simulated central field defect with and without remapped images.
In Vivo Dark-Field Radiography for Early Diagnosis and Staging of Pulmonary Emphysema.
Hellbach, Katharina; Yaroshenko, Andre; Meinel, Felix G; Yildirim, Ali Ö; Conlon, Thomas M; Bech, Martin; Mueller, Mark; Velroyen, Astrid; Notohamiprodjo, Mike; Bamberg, Fabian; Auweter, Sigrid; Reiser, Maximilian; Eickelberg, Oliver; Pfeiffer, Franz
2015-07-01
The aim of this study was to evaluate the suitability of in vivo x-ray dark-field radiography for early-stage diagnosis of pulmonary emphysema in mice. Furthermore, we aimed to analyze how the dark-field signal correlates with morphological changes of lung architecture at distinct stages of emphysema. Female 8- to 10-week-old C57Bl/6N mice were used throughout all experiments. Pulmonary emphysema was induced by orotracheal injection of porcine pancreatic elastase (80-U/kg body weight) (n = 30). Control mice (n = 11) received orotracheal injection of phosphate-buffered saline. To monitor the temporal patterns of emphysema development over time, the mice were imaged 7, 14, or 21 days after the application of elastase or phosphate-buffered saline. X-ray transmission and dark-field images were acquired with a prototype grating-based small-animal scanner. In vivo pulmonary function tests were performed before killing the animals. In addition, lungs were obtained for detailed histopathological analysis, including mean cord length (MCL) quantification as a parameter for the assessment of emphysema. Three blinded readers, all of them experienced radiologists and familiar with dark-field imaging, were asked to grade the severity of emphysema for both dark-field and transmission images. Histopathology and MCL quantification confirmed the introduction of different stages of emphysema, which could be clearly visualized and differentiated on the dark-field radiograms, whereas early stages were not detected on transmission images. The correlation between MCL and dark-field signal intensities (r = 0.85) was significantly higher than the correlation between MCL and transmission signal intensities (r = 0.37). The readers' visual ratings for dark-field images correlated significantly better with MCL (r = 0.85) than visual ratings for transmission images (r = 0.36). Interreader agreement and the diagnostic accuracy of both quantitative and visual assessment were significantly higher for dark-field imaging than those for conventional transmission images. X-ray dark-field radiography can reliably visualize different stages of emphysema in vivo and demonstrates significantly higher diagnostic accuracy for early stages of emphysema than conventional attenuation-based radiography.
Age and visual impairment decrease driving performance as measured on a closed-road circuit.
Wood, Joanne M
2002-01-01
In this study the effects of visual impairment and age on driving were investigated and related to visual function. Participants were 139 licensed drivers (young, middle-aged, and older participants with normal vision, and older participants with ocular disease). Driving performance was assessed during the daytime on a closed-road driving circuit. Visual performance was assessed using a vision testing battery. Age and visual impairment had a significant detrimental effect on recognition tasks (detection and recognition of signs and hazards), time to complete driving tasks (overall course time, reversing, and maneuvering), maneuvering ability, divided attention, and an overall driving performance index. All vision measures were significantly affected by group membership. A combination of motion sensitivity, useful field of view (UFOV), Pelli-Robson letter contrast sensitivity, and dynamic acuity could predict 50% of the variance in overall driving scores. These results indicate that older drivers with either normal vision or visual impairment had poorer driving performance compared with younger or middle-aged drivers with normal vision. The inclusion of tests such as motion sensitivity and the UFOV significantly improve the predictive power of vision tests for driving performance. Although such measures may not be practical for widespread screening, their application in selected cases should be considered.
Singh, Manav Deep; Jain, Kanika
2017-11-01
To find out whether 30-2 Swedish Interactive Threshold Algorithm (SITA) Fast is comparable to 30-2 SITA Standard as a tool for perimetry among the patients with intracranial tumors. This was a prospective cross-sectional study involving 80 patients aged ≥18 years with imaging proven intracranial tumors and visual acuity better than 20/60. The patients underwent multiple visual field examinations using the two algorithms till consistent and repeatable results were obtained. A total of 140 eyes of 80 patients were analyzed. Almost 60% of patients undergoing perimetry with SITA Standard required two or more sessions to obtain consistent results, whereas the same could be obtained in 81.42% with SITA Fast in the first session itself. Of 140 eyes, 70 eyes had recordable field defects and the rest had no defects as detected by either of the two algorithms. Mean deviation (MD) (P = 0.56), pattern standard deviation (PSD) (P = 0.22), visual field index (P = 0.83) and number of depressed points at P < 5%, 2%, 1%, and 0.5% on MD and PSD probability plots showed no statistically significant difference between two algorithms. Bland-Altman test showed that considerable variability existed between two algorithms. Perimetry performed by SITA Standard and SITA Fast algorithm of Humphrey Field Analyzer gives comparable results among the patients of intracranial tumors. Being more time efficient and with a shorter learning curve, SITA Fast my be recommended as a standard test for the purpose of perimetry among these patients.
Do the Eyes Have It? Using Eye Tracking to Assess Students Cognitive Dimensions
ERIC Educational Resources Information Center
Nisiforou, Efi A.; Laghos, Andrew
2013-01-01
Field dependence/independence (FD/FI) is a significant dimension of cognitive styles. The paper presents results of a study that seeks to identify individuals' level of field independence during visual stimulus tasks processing. Specifically, it examined the relationship between the Hidden Figure Test (HFT) scores and the eye tracking metrics.…
Lauer, Richard T.; Keshner, Emily A.
2011-01-01
The effect of continuous visual flow on the ability to regain and maintain postural orientation was examined. Fourteen young (20–39 years old) and 14 older women (60–79 years old) stood quietly during 3° (30°/s) dorsiflexion tilt of the support surface combined with 30° and 45°/s upward or downward pitch rotations of the visual field. The support surface was held tilted for 30 s and then returned to neutral over a 30-s period while the visual field continued to rotate. Segmental displacement and bilateral tibialis anterior and gastrocnemius muscle EMG responses were recorded. Continuous wavelet transforms were calculated for each muscle EMG response. An instantaneous mean frequency curve (IMNF) of muscle activity, center of mass (COM), center of pressure (COP), and angular excursion at the hip and ankle were used in a functional principal component analysis (fPCA). Functional component weights were calculated and compared with mixed model repeated measures ANOVAs. The fPCA revealed greatest mathematical differences in COM and COP responses between groups or conditions during the period that the platform transitioned from the sustained tilt to a return to neutral position. Muscle EMG responses differed most in the period following support surface tilt indicating that muscle activity increased to support stabilization against the visual flow. Older women exhibited significantly larger COM and COP responses in the direction of visual field motion and less muscle modulation when the platform returned to neutral than younger women. Results on a Rod and Frame test indicated that older women were significantly more visually dependent than the younger women. We concluded that a stiffer body combined with heightened visual sensitivity in older women critically interferes with their ability to counteract posturally destabilizing environments. PMID:21479659
Lateralization of magnetic compass orientation in a migratory bird
NASA Astrophysics Data System (ADS)
Wiltschko, Wolfgang; Traudt, Joachim; Güntürkün, Onur; Prior, Helmut; Wiltschko, Roswitha
2002-10-01
Lateralization of brain functions, once believed to be a human characteristic, has now been found to be widespread among vertebrates. In birds, asymmetries of visual functions are well studied, with each hemisphere being specialized for different tasks. Here we report lateralized functions of the birds' visual system associated with magnetoperception, resulting in an extreme asymmetry of sensing the direction of the magnetic field. We found that captive migrants tested in cages with the magnetic field as the only available orientation cue were well oriented in their appropriate migratory direction when using their right eye only, but failed to show a significant directional preference when using their left eye. This implies that magnetoreception for compass orientation, assumed to take place in the eyes alongside the visual processes, is strongly lateralized, with a marked dominance of the right eye/left brain hemisphere.
Oxaliplatin-Related Ocular Toxicity
Mesquida, Marina; Sanchez-Dalmau, Bernardo; Ortiz-Perez, Santiago; Pelegrín, Laura; Molina-Fernandez, Juan José; Figueras-Roca, Marc; Casaroli-Marano, Ricardo; Adán, Alfredo
2010-01-01
We report the case of a 52-year-old woman with advanced colorectal cancer who was treated with oxaliplatin on a FOLFOX schedule. After 3 cycles of chemotherapy, she started to complain of visual loss, altered color vision and neurological symptoms. Due to the suspicion of ocular and neurological toxicity, antineoplastic treatment was stopped. Her visual field showed a concentric bilateral scotoma and the electrooculogram test revealed severe impairment of the retinal pigment epithelium. Visual acuity, color vision and visual field recovered completely 8 months later, although electrooculogram remained abnormal. Ocular toxicity has been reported as an infrequent adverse event of oxaliplatin. Findings in this case indicate toxicity of this chemotherapeutic agent on the retinal pigment epithelium, which has not been reported before. This damage could be permanent, and it thus differs from previously described oxaliplatin-induced ocular toxicities, which are usually transient and reversible. With increasing use of oxaliplatin as first-line treatment in advanced colorectal cancer, we have to be aware of this possible toxicity. PMID:21151636
Useful field of view test performance throughout adulthood in subjects without ocular disorders.
Woutersen, Karlijn; van den Berg, Albert V; Boonstra, F Nienke; Theelen, Thomas; Goossens, Jeroen
2018-01-01
Previous research has shown an age-related decline in Useful Field of View (UFOV) test performance, which measures the duration required to extract relevant information from a scene in three subtasks. However, these results are mostly based on data that may have been confounded by (age-related) ocular diseases. We examined UFOV performance in subjects aged 19.5 to 70.3 years to investigate how UFOV performance changes throughout adulthood. All subjects underwent a thorough ophthalmological examination to exclude ocular disorders. We also examined some elementary visual functions, i.e., near and far visual acuity, crowding and contrast sensitivity. We investigated whether these functions were related to age and whether they could explain a possible age-related decline in UFOV performance. The subjects (n = 41) performed very well on almost every measure and reached far better UFOV and visual acuity scores than those reported by other studies that relied on self-reported absence of ocular pathology. We did not find significant relationships between age and any of the elementary visual functions or the first two UFOV subtasks (R2UFOV1 = 0.03, p = 0.25; R2UFOV2 = 0.07, p = 0.10). However, we found an age-related decline in performance on the third UFOV subtask (R2UFOV3 = 0.36, p < 0.001), which was unrelated to performance on the elementary visual function tasks. Our results show that performance on the first two UFOV subtasks as well as central elementary visual functions may remain high in the absence of obvious ophthalmological pathology.
O’Connell, Caitlin; Ho, Leon C.; Murphy, Matthew C.; Conner, Ian P.; Wollstein, Gadi; Cham, Rakie; Chan, Kevin C.
2016-01-01
Human visual performance has been observed to exhibit superiority in localized regions of the visual field across many classes of stimuli. However, the underlying neural mechanisms remain unclear. This study aims to determine if the visual information processing in the human brain is dependent on the location of stimuli in the visual field and the corresponding neuroarchitecture using blood-oxygenation-level-dependent functional MRI (fMRI) and diffusion kurtosis MRI (DKI), respectively in 15 healthy individuals at 3 Tesla. In fMRI, visual stimulation to the lower hemifield showed stronger brain responses and larger brain activation volumes than the upper hemifield, indicative of the differential sensitivity of the human brain across the visual field. In DKI, the brain regions mapping to the lower visual field exhibited higher mean kurtosis but not fractional anisotropy or mean diffusivity when compared to the upper visual field. These results suggested the different distributions of microstructural organization across visual field brain representations. There was also a strong positive relationship between diffusion kurtosis and fMRI responses in the lower field brain representations. In summary, this study suggested the structural and functional brain involvements in the asymmetry of visual field responses in humans, and is important to the neurophysiological and psychological understanding of human visual information processing. PMID:27631541
Concurrent Vision Dysfunctions in Convergence Insufficiency with Traumatic Brain Injury
Alvarez, Tara L.; Kim, Eun H.; Vicci, Vincent R.; Dhar, Sunil K.; Biswal, Bharat B.; Barrett, A. M.
2012-01-01
Purpose This study assessed the prevalence of convergence insufficiency (CI) with and without simultaneous vision dysfunctions within the traumatic brain injury (TBI) sample population because although CI is commonly reported with TBI, the prevalence of concurrent visual dysfunctions with CI in TBI is unknown. Methods A retrospective analysis of 557 medical records from TBI civilian patients was conducted. Patients were all evaluated by a single optometrist. Visual acuity, oculomotor, binocular vision function, accommodation, visual fields, ocular health and vestibular function were assessed. Statistical comparisons between the CI and non-CI, as well as in-patient and out-patient subgroups, were conducted using chi-squared and Z-tests. Results Approximately 9% of the TBI sample had CI without the following simultaneous diagnoses: saccade or pursuit dysfunction; 3rd, 4th, or 6th nerve palsy; visual field deficit; visual spatial inattention/neglect; vestibular dysfunction or nystagmus. Photophobia with CI was observed in 16.3% (N=21/130) and vestibular dysfunction with CI was observed in 18.5% (N=24/130) of the CI subgroup. CI and cranial nerve palsies were common and yielded prevalence rates of 23.3% (N=130/557) and 26.9% (N=150/557), respectively, within the TBI sample. Accommodative dysfunction was common within the non-presbyopic TBI sample with a prevalence of 24.4% (N=76/314). Visual field deficits or unilateral visual spatial inattention/neglect were observed within 29.6% (N=80/270) of the TBI in-patient subgroup and were significantly more prevalent compared to the out-patient subgroup (p<0.001). Most TBI patients had visual acuities of 20/60 or better in the TBI sample (85%;N=473/557). Conclusions CI without simultaneous visual or vestibular dysfunctions was observed in about 9% of the visually symptomatic TBI civilian population studied. A thorough visual and vestibular examination is recommended for all TBI patients. PMID:23190716
The Wundt-Jastrow illusion in the study of spatial hemi-inattention.
Massironi, M; Antonucci, G; Pizzamiglio, L; Vitale, M V; Zoccolotti, P
1988-01-01
A new test to detect unilateral neglect was devised using a modified version of the Wundt-Jastrow area illusion. The test was given to three groups of subjects: left brain damaged (LBD), right brain damaged (RBD) patients and controls. Of RBD patients, 40.4% but no LBD patient or control, showed responses inconsistent with the visual illusion when the determinant features of the illusion pointed to the left visual field. These unexpected responses were highly related to a clinical evaluation of the severity of the hemi-inattention disorder. The sensitivity of this test and of other standard measures of hemi-neglect were compared. The possibility of identifying qualitatively different forms of hemi-neglect was also discussed.
Older drivers and rapid deceleration events: Salisbury Eye Evaluation Driving Study.
Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K
2013-09-01
Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers aged 67-87 were recruited from the Maryland Motor Vehicle Administration's rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created driving monitoring system (DMS) was used to capture rapid deceleration events (RDEs), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers driving<59 miles during the 5-day period of monitoring. However, older drivers with RDE's were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more "fit", with better measures of vision and cognition compared to those who do not have events of rapid deceleration. Copyright © 2012 Elsevier Ltd. All rights reserved.
Older Drivers and Rapid Deceleration Events: Salisbury Eye Evaluation Driving Study
Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K
2012-01-01
Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers ages 67 to 87 were recruited from the Maryland Motor Vehicle Administration’s rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created Driving Monitor System (DMS) was used to capture rapid deceleration events (RDE), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers driving <59 miles during the 5-day period of monitoring. However, older drivers with RDE’s were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more “fit”, with better measures of vision and cognition compared to those who do not have events of rapid deceleration. PMID:22742775
Accuracy of quantitative visual soil assessment
NASA Astrophysics Data System (ADS)
van Leeuwen, Maricke; Heuvelink, Gerard; Stoorvogel, Jetse; Wallinga, Jakob; de Boer, Imke; van Dam, Jos; van Essen, Everhard; Moolenaar, Simon; Verhoeven, Frank; Stoof, Cathelijne
2016-04-01
Visual soil assessment (VSA) is a method to assess soil quality visually, when standing in the field. VSA is increasingly used by farmers, farm organisations and companies, because it is rapid and cost-effective, and because looking at soil provides understanding about soil functioning. Often VSA is regarded as subjective, so there is a need to verify VSA. Also, many VSAs have not been fine-tuned for contrasting soil types. This could lead to wrong interpretation of soil quality and soil functioning when contrasting sites are compared to each other. We wanted to assess accuracy of VSA, while taking into account soil type. The first objective was to test whether quantitative visual field observations, which form the basis in many VSAs, could be validated with standardized field or laboratory measurements. The second objective was to assess whether quantitative visual field observations are reproducible, when used by observers with contrasting backgrounds. For the validation study, we made quantitative visual observations at 26 cattle farms. Farms were located at sand, clay and peat soils in the North Friesian Woodlands, the Netherlands. Quantitative visual observations evaluated were grass cover, number of biopores, number of roots, soil colour, soil structure, number of earthworms, number of gley mottles and soil compaction. Linear regression analysis showed that four out of eight quantitative visual observations could be well validated with standardized field or laboratory measurements. The following quantitative visual observations correlated well with standardized field or laboratory measurements: grass cover with classified images of surface cover; number of roots with root dry weight; amount of large structure elements with mean weight diameter; and soil colour with soil organic matter content. Correlation coefficients were greater than 0.3, from which half of the correlations were significant. For the reproducibility study, a group of 9 soil scientists and 7 farmers carried out quantitative visual observations all independently from each other. All observers assessed five sites, having a sand, peat or clay soil. For almost all quantitative visual observations the spread of observed values was low (coefficient of variation < 1.0), except for the number of biopores and gley mottles. Furthermore, farmers' observed mean values were significantly higher than soil scientists' mean values, for soil structure, amount of gley mottles and compaction. This study showed that VSA could be a valuable tool to assess soil quality. Subjectivity, due to the background of the observer, might influence the outcome of visual assessment of some soil properties. In countries where soil analyses can easily be carried out, VSA might be a good replenishment to available soil chemical analyses, and in countries where it is not feasible to carry out soil analyses, VSA might be a good start to assess soil quality.
The Symmetry of Visual Fields in Chromatic Discrimination
ERIC Educational Resources Information Center
Danilova, M. V.; Mollon, J. D.
2009-01-01
Both classical and recent reports suggest a right-hemisphere superiority for color discrimination. Testing highly-trained normal subjects and taking care to eliminate asymmetries from the testing situation, we found no significant differences between left and right hemifields or between upper and lower hemifields. This was the case for both of the…
Effect of prolonged bedrest and plus Gz acceleration on peripheral visual response time
NASA Technical Reports Server (NTRS)
Haines, R. F.
1973-01-01
Peripheral visual response time changes during +G sub z acceleration following fourteen days of bedrest are considered as well as what effect prolonged bedrest has upon this response. Eighteen test lights, placed 10 deg are apart along the horizontal meridian of the subject's field of view, were presented in a random sequence. The subject was instructed to press a button as soon as a light appeared. Response time testing occurred periodically during bedrest and continuously during centrifugation testing. The results indicate that: (1) mean response time is significantly longer to stimuli imaged in the far periphery than to stimuli imaged closer to the line of sight; (2) mean response time at each stimulus position tends to be longer at plateau g than during the preacceleration baseline period; (3) mean response time tends to lengthen as the g level is increased; (4) peripheral visual response time during +G sub x acceleration at 2, 3.2, and 3.8 g was not a reliable advanced indicator that blackout was going to occur; and (5) the subject's field of view collapsed rapidly just before blackout. Bedrest data showed that the distribution of response times to stimuli imaged across the subject's horizontal retinal meridian remained remarkably constant from day to day during both the bedrest and recovery periods.
Oh, Se-Il; Kim, Jin-Kyung; Park, So-Yeon
2015-12-01
[Purpose] This study aimed to examine the effects of visual field with prism glasses, and intensive upper limb functional training on reduction of hemineglect and improvement in upper limb function and activities of daily living in three stroke patients with hemineglect. [Subjects] This study included three stroke patients hospitalized in a sanatorium. [Methods] Intervention treatment involving prism glass use for 12 hours and 30 minutes and paretic side upper limb training was conducted 5 days a week for 15 weeks. Three upper limb training tasks (hitting a balloon, passing through a ring, and reading a newspaper) were performed for 10 minutes each session, for a total of 30 minutes. Line by Section, Motor-Free Visual Perception Test-3 (MVPT-3), Manual Function Test (MFT), Box & Block Test (BBT), and Assessment of Motor and Process Skills (AMPS) were conducted before and after intervention. [Results] Subjects' hemineglect decreased and upper limb function on the paretic side improved after intervention, which enhanced activities of daily living. [Conclusion] Prism glass use and paretic upper limb functional training effectively ameliorated stroke patients' hemineglect and improved upper limb function. Future research should focus on prism glasses that provide a wide visual field for use in patients with different conditions.
Visual acuity and visual field impairment in Usher syndrome.
Edwards, A; Fishman, G A; Anderson, R J; Grover, S; Derlacki, D J
1998-02-01
To determine the extent of visual acuity and visual field impairment in patients with types 1 and 2 Usher syndrome. The records of 53 patients with type 1 and 120 patients with type 2 Usher syndrome were reviewed for visual acuity and visual field area at their most recent visit. Visual field areas were determined by planimetry of the II4e and V4e isopters obtained with a Goldmann perimeter. Both ordinary and logistic regression models were used to evaluate differences in visual acuity and visual field impairment between patients with type 1 and type 2 Usher syndrome. The difference in visual acuity of the better eye between patients with type 1 and type 2 varied by patient age (P=.01, based on a multiple regression model). The maximum difference in visual acuity between the 2 groups occurred during the third and fourth decades of life (with the type 1 patients being more impaired), while more similar acuities were seen in both younger and older patients. Fifty-one percent (n=27) of the type 1 patients had a visual acuity of 20/40 or better in at least 1 eye compared with 72% (n=87) of the type 2 patients (age-adjusted odds ratio, 3.9). Visual field area to both the II4e (P=.001) and V4e (P<.001) targets was more impaired in the better eye of type 1 patients than type 2 patients. A concentric central visual field greater than 20 degrees in at least 1 eye was present in 20 (59%) of the available 34 visual fields of type 1 patients compared with 70 (67%) of the available 104 visual fields of type 2 patients (age-adjusted odds ratio, 2.9) with the V4e target and in 6 (21%) of the available 29 visual fields of type 1 patients compared with 36 (38%) of the available 94 visual fields of type 2 patients (age-adjusted odds ratio, 4.9) with the II4e target. The fraction of patients who had a visual acuity of 20/40 or better and a concentric central visual field greater than 20 degrees to the II4e target in at least 1 eye was 17% (n=5) in the type 1 patients and 35% (n=33) in the type 2 patients (age-adjusted odds ratio, 3.9). Visual acuity and visual field area were more impaired in patients with type 1 than type 2 Usher syndrome. Of note, 27 of 53 type 1 (51%) and 87 of 120 type 2 (72%) patients had a visual acuity of 20/40 or better in at least 1 eye. These data are useful for overall counseling of patients with Usher syndrome.
Kovalska, M P; Bürki, E; Schoetzau, A; Orguel, S F; Orguel, S; Grieshaber, M C
2011-04-01
The distinction of real progression from test variability in visual field (VF) series may be based on clinical judgment, on trend analysis based on follow-up of test parameters over time, or on identification of a significant change related to the mean of baseline exams (event analysis). The aim of this study was to compare a new population-based method (Octopus field analysis, OFA) with classic regression analyses and clinical judgment for detecting glaucomatous VF changes. 240 VF series of 240 patients with at least 9 consecutive examinations available were included into this study. They were independently classified by two experienced investigators. The results of such a classification served as a reference for comparison for the following statistical tests: (a) t-test global, (b) r-test global, (c) regression analysis of 10 VF clusters and (d) point-wise linear regression analysis. 32.5 % of the VF series were classified as progressive by the investigators. The sensitivity and specificity were 89.7 % and 92.0 % for r-test, and 73.1 % and 93.8 % for the t-test, respectively. In the point-wise linear regression analysis, the specificity was comparable (89.5 % versus 92 %), but the sensitivity was clearly lower than in the r-test (22.4 % versus 89.7 %) at a significance level of p = 0.01. A regression analysis for the 10 VF clusters showed a markedly higher sensitivity for the r-test (37.7 %) than the t-test (14.1 %) at a similar specificity (88.3 % versus 93.8 %) for a significant trend (p = 0.005). In regard to the cluster distribution, the paracentral clusters and the superior nasal hemifield progressed most frequently. The population-based regression analysis seems to be superior to the trend analysis in detecting VF progression in glaucoma, and may eliminate the drawbacks of the event analysis. Further, it may assist the clinician in the evaluation of VF series and may allow better visualization of the correlation between function and structure owing to VF clusters. © Georg Thieme Verlag KG Stuttgart · New York.
Indoor Spatial Updating with Reduced Visual Information
Legge, Gordon E.; Gage, Rachel; Baek, Yihwa; Bochsler, Tiana M.
2016-01-01
Purpose Spatial updating refers to the ability to keep track of position and orientation while moving through an environment. People with impaired vision may be less accurate in spatial updating with adverse consequences for indoor navigation. In this study, we asked how artificial restrictions on visual acuity and field size affect spatial updating, and also judgments of the size of rooms. Methods Normally sighted young adults were tested with artificial restriction of acuity in Mild Blur (Snellen 20/135) and Severe Blur (Snellen 20/900) conditions, and a Narrow Field (8°) condition. The subjects estimated the dimensions of seven rectangular rooms with and without these visual restrictions. They were also guided along three-segment paths in the rooms. At the end of each path, they were asked to estimate the distance and direction to the starting location. In Experiment 1, the subjects walked along the path. In Experiment 2, they were pushed in a wheelchair to determine if reduced proprioceptive input would result in poorer spatial updating. Results With unrestricted vision, mean Weber fractions for room-size estimates were near 20%. Severe Blur but not Mild Blur yielded larger errors in room-size judgments. The Narrow Field was associated with increased error, but less than with Severe Blur. There was no effect of visual restriction on estimates of distance back to the starting location, and only Severe Blur yielded larger errors in the direction estimates. Contrary to expectation, the wheelchair subjects did not exhibit poorer updating performance than the walking subjects, nor did they show greater dependence on visual condition. Discussion If our results generalize to people with low vision, severe deficits in acuity or field will adversely affect the ability to judge the size of indoor spaces, but updating of position and orientation may be less affected by visual impairment. PMID:26943674
Indoor Spatial Updating with Reduced Visual Information.
Legge, Gordon E; Gage, Rachel; Baek, Yihwa; Bochsler, Tiana M
2016-01-01
Spatial updating refers to the ability to keep track of position and orientation while moving through an environment. People with impaired vision may be less accurate in spatial updating with adverse consequences for indoor navigation. In this study, we asked how artificial restrictions on visual acuity and field size affect spatial updating, and also judgments of the size of rooms. Normally sighted young adults were tested with artificial restriction of acuity in Mild Blur (Snellen 20/135) and Severe Blur (Snellen 20/900) conditions, and a Narrow Field (8°) condition. The subjects estimated the dimensions of seven rectangular rooms with and without these visual restrictions. They were also guided along three-segment paths in the rooms. At the end of each path, they were asked to estimate the distance and direction to the starting location. In Experiment 1, the subjects walked along the path. In Experiment 2, they were pushed in a wheelchair to determine if reduced proprioceptive input would result in poorer spatial updating. With unrestricted vision, mean Weber fractions for room-size estimates were near 20%. Severe Blur but not Mild Blur yielded larger errors in room-size judgments. The Narrow Field was associated with increased error, but less than with Severe Blur. There was no effect of visual restriction on estimates of distance back to the starting location, and only Severe Blur yielded larger errors in the direction estimates. Contrary to expectation, the wheelchair subjects did not exhibit poorer updating performance than the walking subjects, nor did they show greater dependence on visual condition. If our results generalize to people with low vision, severe deficits in acuity or field will adversely affect the ability to judge the size of indoor spaces, but updating of position and orientation may be less affected by visual impairment.
Reading performance after vision rehabilitation of subjects with homonymous visual field defects.
Gall, Carolin; Sabel, Bernhard A
2012-12-01
To examine whether increased visual functioning after vision-restoration training (VRT) coincides with improved reading abilities. Prospective noncontrolled open-label trial. Controlled laboratory setting for all diagnostic procedures that were conducted before and after 6 months of home-based VRT with telemedicine support. Eleven subjects who had experienced a posterior-parietal stroke and have homonymous visual field defects. Six months of VRT (1 hour daily repeated light stimulation in the partially damaged visual field). VRT outcome measures were the number of detected light stimuli in eye-tracker controlled high-resolution perimetry and the spared visual field within the affected hemifield up to the relative and absolute defect visual field border (square degrees). Enlargements of spared visual field within the affected hemifield were correlated with changes of reading speed after VRT. After VRT, the number of detected light stimuli increased by 5.02 ± 4.31% (mean ± SD; P = .03). The spared visual field up to the relative defect visual field border increased from 18.09 ± 32.35 square degrees before to 137.40 ± 53.32 after VRT (P = .006), as well as for the absolute defect visual field border from 36.95 ± 33.77 square degrees before VRT to 152.02 ± 49.70 after VRT (P = .005). Reading speed increased from 108.95 ± 33.95 words per minute before VRT to 122.26 ± 30.35 after VRT (P = .017), which significantly correlated with increased spared visual field up to the relative defect visual field border (r = 0.73, P = .016). Measures of eye movement variability did not correlate with VRT outcome. VRT improved visual fields in parafoveal areas, which are most relevant for reading. This finding cannot be explained by changes in eye movement behavior. Because of a significant association between improvements of parafoveal vision and reading speed, we propose that patients with homonymous visual field defects who have reading deficits may benefit from visual stimulation by training. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Differential approach to strategies of segmental stabilisation in postural control.
Isableu, Brice; Ohlmann, Théophile; Crémieux, Jacques; Amblard, Bernard
2003-05-01
The present paper attempts to clarify the between-subjects variability exhibited in both segmental stabilisation strategies and their subordinated or associated sensory contribution. Previous data have emphasised close relationships between the interindividual variability in both the visual control of posture and the spatial visual perception. In this study, we focused on the possible relationships that might link perceptual visual field dependence-independence and the visual contribution to segmental stabilisation strategies. Visual field dependent (FD) and field independent (FI) subjects were selected on the basis of their extreme score in a static rod and frame test where an estimation of the subjective vertical was required. In the postural test, the subjects stood in the sharpened Romberg position in darkness or under normal or stroboscopic illumination, in front of either a vertical or a tilted frame. Strategies of segmental stabilisation of the head, shoulders and hip in the roll plane were analysed by means of their anchoring index (AI). Our hypothesis was that FD subjects might use mainly visual cues for calibrating not only their spatial perception but also their strategies of segmental stabilisation. In the case of visual cue disturbances, a greater visual dependency to the strategies of segmental stabilisation in FD subjects should be validated by observing more systematic "en bloc" functioning (i.e. negative AI) between two adjacent segments. The main results are the following: 1. Strategies of segmental stabilisation differed between both groups and differences were amplified with the deprivation of either total vision and/or static visual cues. 2. In the absence of total vision and/or static visual cues, FD subjects have shown an increased efficiency of the hip stabilisation in space strategy and an "en bloc" operation of the shoulder-hip unit (whole trunk). The last "en bloc" operation was extended to the whole head-trunk unit in darkness, associated with a hip stabilisation in space. 3. The FI subjects have adopted neither a strategy of segmental stabilisation in space nor on the underlying segment, whatever the body segment considered and the visual condition. Thus, in this group, head, shoulder and hip moved independently from each other during stance control, roughly without taking into account the visual condition. The results, emphasising a differential weighting of sensory input involved in both perceptual and postural control, are discussed in terms of the differential choice and/or ability to select the adequate frame of reference common to both cognitive and motor spatial activities. We assumed that a motor-somesthetics "neglect" or a lack of mastering of these inputs/outputs rather than a mere visual dependence in FD subjects would generate these interindividual differences in both spatial perception and postural balance. This proprioceptive "neglect" is assumed to lead FD subjects to sensory reweighting, whereas proprioceptive dominance would lead FI subjects to a greater ability in selecting the adequate frame of reference in the case of intersensory disturbances. Finally, this study also provides evidence for a new interpretation of the visual field dependence-independence dimension in both spatial perception and postural control.
Can we improve clinical prediction of at-risk older drivers?
Bowers, Alex R.; Anastasio, R. Julius; Sheldon, Sarah S.; O’Connor, Margaret G.; Hollis, Ann M.; Howe, Piers D.; Horowitz, Todd S.
2013-01-01
Objectives To conduct a pilot study to evaluate the predictive value of the Montreal Cognitive Assessment test (MoCA) and a brief test of multiple object tracking (MOT) relative to other tests of cognition and attention in identifying at-risk older drivers, and to determine which combination of tests provided the best overall prediction. Methods Forty-seven currently-licensed drivers (58 to 95 years), primarily from a clinical driving evaluation program, participated. Their performance was measured on: (1) a screening test battery, comprising MoCA, MOT, MiniMental State Examination (MMSE), Trail-Making Test, visual acuity, contrast sensitivity, and Useful Field of View (UFOV); and (2) a standardized road test. Results Eighteen participants were rated at-risk on the road test. UFOV subtest 2 was the best single predictor with an area under the curve (AUC) of .84. Neither MoCA nor MOT was a better predictor of the at-risk outcome than either MMSE or UFOV, respectively. The best four-test combination (MMSE, UFOV subtest 2, visual acuity and contrast sensitivity) was able to identify at-risk drivers with 95% specificity and 80% sensitivity (.91 AUC). Conclusions Although the best four-test combination was much better than a single test in identifying at-risk drivers, there is still much work to do in this field to establish test batteries that have both high sensitivity and specificity. PMID:23954688
Li, Jingjing; Li, Jinrong; Chen, Zidong; Liu, Jing; Yuan, Junpeng; Cai, Xiaoxiao; Deng, Daming; Yu, Minbin
2017-01-01
We investigate the efficacy of a novel dichoptic mapping paradigm in evaluating visual function of anisometropic amblyopes. Using standard clinical measures of visual function (visual acuity, stereo acuity, Bagolini lenses, and neutral density filters) and a novel quantitative mapping technique, 26 patients with anisometropic amblyopia (mean age = 19.15 ± 4.42 years) were assessed. Two additional psychophysical interocular suppression measurements were tested with dichoptic global motion coherence and binocular phase combination tasks. Luminance reduction was achieved by placing neutral density filters in front of the normal eye. Our study revealed that suppression changes across the central 10° visual field by mean luminance modulation in amblyopes as well as normal controls. Using simulation and an elimination of interocular suppression, we identified a novel method to effectively reflect the distribution of suppression in anisometropic amblyopia. Additionally, the new quantitative mapping technique was in good agreement with conventional clinical measures, such as interocular acuity difference (P < 0.001) and stereo acuity (P = 0.005). There was a good consistency between the results of interocular suppression with dichoptic mapping paradigm and the results of the other two psychophysical methods (suppression mapping versus binocular phase combination, P < 0.001; suppression mapping versus global motion coherence, P = 0.005). The dichoptic suppression mapping technique is an effective method to represent impaired visual function in patients with anisometropic amblyopia. It offers a potential in "micro-"antisuppression mapping tests and therapies for amblyopia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholtz, Jean; Plaisant, Catherine; Whiting, Mark A.
The evaluation of visual analytics environments was a topic in Illuminating the Path [Thomas 2005] as a critical aspect of moving research into practice. For a thorough understanding of the utility of the systems available, evaluation not only involves assessing the visualizations, interactions or data processing algorithms themselves, but also the complex processes that a tool is meant to support (such as exploratory data analysis and reasoning, communication through visualization, or collaborative data analysis [Lam 2012; Carpendale 2007]). Researchers and practitioners in the field have long identified many of the challenges faced when planning, conducting, and executing an evaluation ofmore » a visualization tool or system [Plaisant 2004]. Evaluation is needed to verify that algorithms and software systems work correctly and that they represent improvements over the current infrastructure. Additionally to effectively transfer new software into a working environment, it is necessary to ensure that the software has utility for the end-users and that the software can be incorporated into the end-user’s infrastructure and work practices. Evaluation test beds require datasets, tasks, metrics and evaluation methodologies. As noted in [Thomas 2005] it is difficult and expensive for any one researcher to setup an evaluation test bed so in many cases evaluation is setup for communities of researchers or for various research projects or programs. Examples of successful community evaluations can be found [Chinchor 1993; Voorhees 2007; FRGC 2012]. As visual analytics environments are intended to facilitate the work of human analysts, one aspect of evaluation needs to focus on the utility of the software to the end-user. This requires representative users, representative tasks, and metrics that measure the utility to the end-user. This is even more difficult as now one aspect of the test methodology is access to representative end-users to participate in the evaluation. In many cases the sensitive nature of data and tasks and difficult access to busy analysts puts even more of a burden on researchers to complete this type of evaluation. User-centered design goes beyond evaluation and starts with the user [Beyer 1997, Shneiderman 2009]. Having some knowledge of the type of data, tasks, and work practices helps researchers and developers know the correct paths to pursue in their work. When access to the end-users is problematic at best and impossible at worst, user-centered design becomes difficult. Researchers are unlikely to go to work on the type of problems faced by inaccessible users. Commercial vendors have difficulties evaluating and improving their products when they cannot observe real users working with their products. In well-established fields such as web site design or office software design, user-interface guidelines have been developed based on the results of empirical studies or the experience of experts. Guidelines can speed up the design process and replace some of the need for observation of actual users [heuristics review references]. In 2006 when the visual analytics community was initially getting organized, no such guidelines existed. Therefore, we were faced with the problem of developing an evaluation framework for the field of visual analytics that would provide representative situations and datasets, representative tasks and utility metrics, and finally a test methodology which would include a surrogate for representative users, increase interest in conducting research in the field, and provide sufficient feedback to the researchers so that they could improve their systems.« less
Rapid pupil-based assessment of glaucomatous damage.
Chen, Yanjun; Wyatt, Harry J; Swanson, William H; Dul, Mitchell W
2008-06-01
To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the "contrast balance" (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes.
Rapid Pupil-Based Assessment of Glaucomatous Damage
Chen, Yanjun; Wyatt, Harry J.; Swanson, William H.; Dul, Mitchell W.
2010-01-01
Purpose To investigate the ability of a technique employing pupillometry and functionally-shaped stimuli to assess loss of visual function due to glaucomatous optic neuropathy. Methods Pairs of large stimuli, mirror images about the horizontal meridian, were displayed alternately in the upper and lower visual field. Pupil diameter was recorded and analyzed in terms of the “contrast balance” (relative sensitivity to the upper and lower stimuli), and the pupil constriction amplitude to upper and lower stimuli separately. A group of 40 patients with glaucoma was tested twice in a first session, and twice more in a second session, 1 to 3 weeks later. A group of 40 normal subjects was tested with the same protocol. Results Results for the normal subjects indicated functional symmetry in upper/lower retina, on average. Contrast balance results for the patients with glaucoma differed from normal: half the normal subjects had contrast balance within 0.06 log unit of equality and 80% had contrast balance within 0.1 log unit. Half the patients had contrast balances more than 0.1 log unit from equality. Patient contrast balances were moderately correlated with predictions from perimetric data (r = 0.37, p < 0.00001). Contrast balances correctly classified visual field damage in 28 patients (70%), and response amplitudes correctly classified 24 patients (60%). When contrast balance and response amplitude were combined, receiver operating characteristic area for discriminating glaucoma from normal was 0.83. Conclusions Pupillary evaluation of retinal asymmetry provides a rapid method for detecting and classifying visual field defects. In this patient population, classification agreed with perimetry in 70% of eyes. PMID:18521026
Neural attractor network for application in visual field data classification.
Fink, Wolfgang
2004-07-07
The purpose was to introduce a novel method for computer-based classification of visual field data derived from perimetric examination, that may act as a 'counsellor', providing an independent 'second opinion' to the diagnosing physician. The classification system consists of a Hopfield-type neural attractor network that obtains its input data from perimetric examination results. An iterative relaxation process determines the states of the neurons dynamically. Therefore, even 'noisy' perimetric output, e.g., early stages of a disease, may eventually be classified correctly according to the predefined idealized visual field defect (scotoma) patterns, stored as attractors of the network, that are found with diseases of the eye, optic nerve and the central nervous system. Preliminary tests of the classification system on real visual field data derived from perimetric examinations have shown a classification success of over 80%. Some of the main advantages of the Hopfield-attractor-network-based approach over feed-forward type neural networks are: (1) network architecture is defined by the classification problem; (2) no training is required to determine the neural coupling strengths; (3) assignment of an auto-diagnosis confidence level is possible by means of an overlap parameter and the Hamming distance. In conclusion, the novel method for computer-based classification of visual field data, presented here, furnishes a valuable first overview and an independent 'second opinion' in judging perimetric examination results, pointing towards a final diagnosis by a physician. It should not be considered a substitute for the diagnosing physician. Thanks to the worldwide accessibility of the Internet, the classification system offers a promising perspective towards modern computer-assisted diagnosis in both medicine and tele-medicine, for example and in particular, with respect to non-ophthalmic clinics or in communities where perimetric expertise is not readily available.
Plath, Jenny A.; Entler, Brian V.; Kirkerud, Nicholas H.; Schlegel, Ulrike; Galizia, C. Giovanni; Barron, Andrew B.
2017-01-01
The honey bee is an excellent visual learner, but we know little about how and why it performs so well, or how visual information is learned by the bee brain. Here we examined the different roles of two key integrative regions of the brain in visual learning: the mushroom bodies and the central complex. We tested bees' learning performance in a new assay of color learning that used electric shock as punishment. In this assay a light field was paired with electric shock. The other half of the conditioning chamber was illuminated with light of a different wavelength and not paired with shocks. The unrestrained bee could run away from the light stimulus and thereby associate one wavelength with punishment, and the other with safety. We compared learning performance of bees in which either the central complex or mushroom bodies had been transiently inactivated by microinjection of the reversible anesthetic procaine. Control bees learned to escape the shock-paired light field and to spend more time in the safe light field after a few trials. When ventral lobe neurons of the mushroom bodies were silenced, bees were no longer able to associate one light field with shock. By contrast, silencing of one collar region of the mushroom body calyx did not alter behavior in the learning assay in comparison to control treatment. Bees with silenced central complex neurons did not leave the shock-paired light field in the middle trials of training, even after a few seconds of being shocked. We discussed how mushroom bodies and the central complex both contribute to aversive visual learning with an operant component. PMID:28611605
Avoiding Focus Shifts in Surgical Telementoring Using an Augmented Reality Transparent Display.
Andersen, Daniel; Popescu, Voicu; Cabrera, Maria Eugenia; Shanghavi, Aditya; Gomez, Gerardo; Marley, Sherri; Mullis, Brian; Wachs, Juan
2016-01-01
Conventional surgical telementoring systems require the trainee to shift focus away from the operating field to a nearby monitor to receive mentor guidance. This paper presents the next generation of telementoring systems. Our system, STAR (System for Telementoring with Augmented Reality) avoids focus shifts by placing mentor annotations directly into the trainee's field of view using augmented reality transparent display technology. This prototype was tested with pre-medical and medical students. Experiments were conducted where participants were asked to identify precise operating field locations communicated to them using either STAR or a conventional telementoring system. STAR was shown to improve accuracy and to reduce focus shifts. The initial STAR prototype only provides an approximate transparent display effect, without visual continuity between the display and the surrounding area. The current version of our transparent display provides visual continuity by showing the geometry and color of the operating field from the trainee's viewpoint.
Predicting Visual Disability in Glaucoma With Combinations of Vision Measures.
Lin, Stephanie; Mihailovic, Aleksandra; West, Sheila K; Johnson, Chris A; Friedman, David S; Kong, Xiangrong; Ramulu, Pradeep Y
2018-04-01
We characterized vision in glaucoma using seven visual measures, with the goals of determining the dimensionality of vision, and how many and which visual measures best model activity limitation. We analyzed cross-sectional data from 150 older adults with glaucoma, collecting seven visual measures: integrated visual field (VF) sensitivity, visual acuity, contrast sensitivity (CS), area under the log CS function, color vision, stereoacuity, and visual acuity with noise. Principal component analysis was used to examine the dimensionality of vision. Multivariable regression models using one, two, or three vision tests (and nonvisual predictors) were compared to determine which was best associated with Rasch-analyzed Glaucoma Quality of Life-15 (GQL-15) person measure scores. The participants had a mean age of 70.2 and IVF sensitivity of 26.6 dB, suggesting mild-to-moderate glaucoma. All seven vision measures loaded similarly onto the first principal component (eigenvectors, 0.220-0.442), which explained 56.9% of the variance in vision scores. In models for GQL scores, the maximum adjusted- R 2 values obtained were 0.263, 0.296, and 0.301 when using one, two, and three vision tests in the models, respectively, though several models in each category had similar adjusted- R 2 values. All three of the best-performing models contained CS. Vision in glaucoma is a multidimensional construct that can be described by several variably-correlated vision measures. Measuring more than two vision tests does not substantially improve models for activity limitation. A sufficient description of disability in glaucoma can be obtained using one to two vision tests, especially VF and CS.
Basic quantitative assessment of visual performance in patients with very low vision.
Bach, Michael; Wilke, Michaela; Wilhelm, Barbara; Zrenner, Eberhart; Wilke, Robert
2010-02-01
A variety of approaches to developing visual prostheses are being pursued: subretinal, epiretinal, via the optic nerve, or via the visual cortex. This report presents a method of comparing their efficacy at genuinely improving visual function, starting at no light perception (NLP). A test battery (a computer program, Basic Assessment of Light and Motion [BaLM]) was developed in four basic visual dimensions: (1) light perception (light/no light), with an unstructured large-field stimulus; (2) temporal resolution, with single versus double flash discrimination; (3) localization of light, where a wedge extends from the center into four possible directions; and (4) motion, with a coarse pattern moving in one of four directions. Two- or four-alternative, forced-choice paradigms were used. The participants' responses were self-paced and delivered with a keypad. The feasibility of the BaLM was tested in 73 eyes of 51 patients with low vision. The light and time test modules discriminated between NLP and light perception (LP). The localization and motion modules showed no significant response for NLP but discriminated between LP and hand movement (HM). All four modules reached their ceilings in the acuity categories higher than HM. BaLM results systematically differed between the very-low-acuity categories NLP, LP, and HM. Light and time yielded similar results, as did localization and motion; still, for assessing the visual prostheses with differing temporal characteristics, they are not redundant. The results suggest that this simple test battery provides a quantitative assessment of visual function in the very-low-vision range from NLP to HM.
Effects of visual imagery on the accommodation response
NASA Technical Reports Server (NTRS)
Malmstrom, F. V.; Randle, R. J.
1976-01-01
Twenty-seven naive male subjects were tested to determine whether they could effect appropriate accommodation changes in an empty field by 'thinking near' and 'thinking far'. Evidence indicated that naive subjects could effect significant and appropriate accommodation changes, but only about a steady-state value of 1.0 diopter. Additionally, the data support the hypothesis that the resting state of accommodation is not at the visual far point, but, rather, at about 1.0 diopter.
Retinitis Pigmentosa Sine Pigmento Mimicking a Chiasm Disease
Pellegrini, Francesco; Prosdocimo, Giovanni; Romano, Francesco; Interlandi, Emanuela
2017-01-01
ABSTRACT A 75-year-old woman presented to her ophthalmologist complaining of visual loss for several years. The ophthalmic examination was remarkable for a bitemporal visual field defect. Magnetic resonance imaging (MRI) scan of the brain was normal without evidence of chiasm compression. Neuro-ophthalmic examination was consistent with a retinal rather than a chiasmal disease. Retinal multimodal imaging helped in the correct diagnosis of retinitis pigmentosa, later confirmed by genetic testing. PMID:29344059
Grubert, Anna; Eimer, Martin
2015-11-11
During the maintenance of task-relevant objects in visual working memory, the contralateral delay activity (CDA) is elicited over the hemisphere opposite to the visual field where these objects are presented. The presence of this lateralised CDA component demonstrates the existence of position-dependent object representations in working memory. We employed a change detection task to investigate whether the represented object locations in visual working memory are shifted in preparation for the known location of upcoming comparison stimuli. On each trial, bilateral memory displays were followed after a delay period by bilateral test displays. Participants had to encode and maintain three visual objects on one side of the memory display, and to judge whether they were identical or different to three objects in the test display. Task-relevant memory and test stimuli were located in the same visual hemifield in the no-shift task, and on opposite sides in the horizontal shift task. CDA components of similar size were triggered contralateral to the memorized objects in both tasks. The absence of a polarity reversal of the CDA in the horizontal shift task demonstrated that there was no preparatory shift of memorized object location towards the side of the upcoming comparison stimuli. These results suggest that visual working memory represents the locations of visual objects during encoding, and that the matching of memorized and test objects at different locations is based on a comparison process that can bridge spatial translations between these objects. This article is part of a Special Issue entitled SI: Prediction and Attention. Copyright © 2014 Elsevier B.V. All rights reserved.
Cecocentral scotoma as the initial manifestation of subacute bacterial endocarditis
Strauss, Danielle Savitsky; Baharestani, Samuel; Nemiroff, Julia; Amesur, Kiran; Howard, David
2011-01-01
Introduction: We report a case of a 67-year-old male who presented with a cecocentral scotoma caused by a septic embolus from subacute bacterial endocarditis (SBE). Methods: A 67-year-old man presented with sudden, painless decreased vision in the left eye. A dilated fundoscopic exam, Humphrey visual field test, transthoracic echocardiogram, abdominal computed tomography (CT), and blood cultures were all performed. Results: A dilated fundoscopic exam revealed temporal segmental optic disc pallor on the left, and Humphrey visual field testing demonstrated a dense left cecocentral scotoma. When the patient developed fever (103. 9°F) and palpitations, transthoracic echocardiogram revealed valvular vegetations, and contrast CT of the abdomen revealed an abscess in the dome of the liver likely due to an infectious thrombus. Blood cultures grew viridians group streptococci in three separate peripheral collections. Conclusion: This case illustrates that a sudden cecocentral scotoma may be the initial manifestation of SBE. PMID:21468335
Tu, Joanna H; Foote, Katharina G; Lujan, Brandon J; Ratnam, Kavitha; Qin, Jia; Gorin, Michael B; Cunningham, Emmett T; Tuten, William S; Duncan, Jacque L; Roorda, Austin
2017-09-01
Confocal adaptive optics scanning laser ophthalmoscope (AOSLO) images provide a sensitive measure of cone structure. However, the relationship between structural findings of diminished cone reflectivity and visual function is unclear. We used fundus-referenced testing to evaluate visual function in regions of apparent cone loss identified using confocal AOSLO images. A patient diagnosed with acute bilateral foveolitis had spectral-domain optical coherence tomography (SD-OCT) (Spectralis HRA + OCT system [Heidelberg Engineering, Vista, CA, USA]) images indicating focal loss of the inner segment-outer segment junction band with an intact, but hyper-reflective, external limiting membrane. Five years after symptom onset, visual acuity had improved from 20/80 to 20/25, but the retinal appearance remained unchanged compared to 3 months after symptoms began. We performed structural assessments using SD-OCT, directional OCT (non-standard use of a prototype on loan from Carl Zeiss Meditec) and AOSLO (custom-built system). We also administered fundus-referenced functional tests in the region of apparent cone loss, including analysis of preferred retinal locus (PRL), AOSLO acuity, and microperimetry with tracking SLO (TSLO) (prototype system). To determine AOSLO-corrected visual acuity, the scanning laser was modulated with a tumbling E consistent with 20/30 visual acuity. Visual sensitivity was assessed in and around the lesion using TSLO microperimetry. Complete eye examination, including standard measures of best-corrected visual acuity, visual field tests, color fundus photos, and fundus auto-fluorescence were also performed. Despite a lack of visible cone profiles in the foveal lesion, fundus-referenced vision testing demonstrated visual function within the lesion consistent with cone function. The PRL was within the lesion of apparent cone loss at the fovea. AOSLO visual acuity tests were abnormal, but measurable: for trials in which the stimulus remained completely within the lesion, the subject got 48% correct, compared to 78% correct when the stimulus was outside the lesion. TSLO microperimetry revealed reduced, but detectible, sensitivity thresholds within the lesion. Fundus-referenced visual testing proved useful to identify functional cones despite apparent photoreceptor loss identified using AOSLO and SD-OCT. While AOSLO and SD-OCT appear to be sensitive for the detection of abnormal or absent photoreceptors, changes in photoreceptors that are identified with these imaging tools do not correlate completely with visual function in every patient. Fundus-referenced vision testing is a useful tool to indicate the presence of cones that may be amenable to recovery or response to experimental therapies despite not being visible on confocal AOSLO or SD-OCT images.
Wilkins, Luke; Gray, Rob
2015-08-01
It has been shown recently that stroboscopic visual training can improve visual-perceptual abilities, such as central field motion sensitivity and anticipatory timing. Such training should also improve a sports skill that relies on these perceptual abilities, namely ball catching. Thirty athletes (12 women, 18 men; M age=22.5 yr., SD=4.7) were assigned to one of two types of stroboscopic training groups: a variable strobe rate (VSR) group for which the off-time of the glasses was systematically increased (as in previous research) and a constant strobe rate group (CSR) for which the glasses were always set at the shortest off-time. Training involved simple, tennis ball-catching drills (9×20 min.) occurring over a 6-wk. In pre- and post-training, the participants completed a one-handed ball-catching task and the Useful Field of View (UFOV) and the Motion in Depth Sensitivity (MIDS) tests. Since the CSR condition used in the present study has been shown to have no effect on catching performance, it was predicted that the VSR group would show significantly greater improvement pre-post-training. There were no significant differences between the CSR and VSR on any of the tests. However, changes in catching performance (total balls caught) pre-post-training were significantly correlated with changes in scores for the UFOV single-task and MIDS tests. That is, regardless of group, participants whose perceptual-cognitive performance improved in the post-test were significantly more likely to improve their catching performance. This suggests that the perceptual changes observed in previous stroboscopic training studies may be linked to changes in sports skill performance.
Nakanishi, Masaki; Wang, Yu-Te; Jung, Tzyy-Ping; Zao, John K; Chien, Yu-Yi; Diniz-Filho, Alberto; Daga, Fabio B; Lin, Yuan-Pin; Wang, Yijun; Medeiros, Felipe A
2017-06-01
The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.
The Attentional Field Revealed by Single-Voxel Modeling of fMRI Time Courses
DeYoe, Edgar A.
2015-01-01
The spatial topography of visual attention is a distinguishing and critical feature of many theoretical models of visuospatial attention. Previous fMRI-based measurements of the topography of attention have typically been too crude to adequately test the predictions of different competing models. This study demonstrates a new technique to make detailed measurements of the topography of visuospatial attention from single-voxel, fMRI time courses. Briefly, this technique involves first estimating a voxel's population receptive field (pRF) and then “drifting” attention through the pRF such that the modulation of the voxel's fMRI time course reflects the spatial topography of attention. The topography of the attentional field (AF) is then estimated using a time-course modeling procedure. Notably, we are able to make these measurements in many visual areas including smaller, higher order areas, thus enabling a more comprehensive comparison of attentional mechanisms throughout the full hierarchy of human visual cortex. Using this technique, we show that the AF scales with eccentricity and varies across visual areas. We also show that voxels in multiple visual areas exhibit suppressive attentional effects that are well modeled by an AF having an enhancing Gaussian center with a suppressive surround. These findings provide extensive, quantitative neurophysiological data for use in modeling the psychological effects of visuospatial attention. PMID:25810532
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
21 CFR 886.1360 - Visual field laser instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Visual field laser instrument. 886.1360 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument. (a) Identification. A visual field laser instrument is an AC-powered device intended to provide...
Patino, Cecilia M.; Varma, Rohit; Azen, Stanley P.; Conti, David V.; Nichol, Michael B.; McKean-Cowdin, Roberta
2010-01-01
Purpose To assess the impact of change in visual field (VF) on change in health related quality of life (HRQoL) at the population level. Design Prospective cohort study Participants 3,175 Los Angles Latino Eye Study (LALES) participants Methods Objective measures of VF and visual acuity and self-reported HRQoL were collected at baseline and 4-year follow-up. Analysis of covariance was used to evaluate mean differences in change of HRQoL across severity levels of change in VF and to test for effect modification by covariates. Main outcome measures General and vision-specific HRQoL. Results Of 3,175 participants, 1430 (46%) showed a change in VF (≥1 decibel [dB]) and 1651, 1715 (54%) reported a clinically important change (≥5 points) in vision-specific HRQoL. Progressive worsening and improvement in the VF were associated with increasing losses and gains in vision-specific HRQoL for the composite score and 10 of its 11 subscales (all Ptrends<0.05). Losses in VF > 5 dB and gains > 3 dB were associated with clinically meaningful losses and gains in vision-specific HRQoL, respectively. Areas of vision-specific HRQoL most affected by greater losses in VF were driving, dependency, role-functioning, and mental health. The effect of change in VF (loss or gain) on mean change in vision-specific HRQoL varied by level of baseline vision loss (in visual field and/or visual acuity) and by change in visual acuity (all P-interactions<0.05). Those with moderate/severe VF loss at baseline and with a > 5 dB loss in visual field during the study period had a mean loss of vision-specific HRQoL of 11.3 points, while those with no VF loss at baseline had a mean loss of 0.97 points Similarly, with a > 5 dB loss in VF and baseline visual acuity impairment (mild/severe) there was a loss in vision-specific HRQoL of 10.5 points, whereas with no visual acuity impairment at baseline there was a loss of vision-specific HRQoL of 3.7 points. Conclusion Both losses and gains in VF produce clinically meaningful changes in vision-specific HRQoL. In the presence of pre-existing vision loss (VF and visual acuity), similar levels of visual field change produce greater losses in quality of life. PMID:21458074
2000-12-01
To investigate the effect of cataract on visual function and the role of cataract in explaining a race-treatment interaction in outcomes of glaucoma surgery. The Advanced Glaucoma Intervention Study (AGIS) enrolled 332 black patients (451 eyes) and 249 white patients (325 eyes) with advanced glaucoma. Eyes were randomly assigned to an argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy sequence or a trabeculectomy-ALT-trabeculectomy sequence. From the AGIS experience with cataract surgery during follow-up, we estimated the expected change in visual function scores from before cataract surgery to after cataract surgery. Then, for eyes with cataract not removed, we used these estimates of expected change to adjust visual function scores for the presumed effects of cataract. In turn, we used the adjusted scores to obtain cataract-adjusted main outcome measures. Average percent of eyes with decrease of visual field (APDVF) and average percent of eyes with decrease of visual acuity (APDVA). Within the 2 months before cataract surgery, visual acuity was better in eyes of white patients than of black patients by an average of approximately 2 lines on the visual acuity test chart. Cataract surgery improved visual acuity and visual field defect scores, with the amounts of improvement greater when preoperative visual acuity was lower. Adjustments for cataract brought about the following relative reductions: for APDVF, a relative reduction of 5% to 11% in black patients and 9% to 11% in white patients; for APDVA, a relative reduction of 45% to 49% in black patients and 31% to 38% in white patients; and for the APDVF and APDVA race-treatment interactions, relative reductions of 25% and 45%, respectively. On average, visual function scores improved after cataract surgery. The findings of reduced race-treatment interactions after adjustment for cataract do not alter our earlier conclusion that the AGIS 7-year results support use of the ALT-trabeculectomy-trabeculectomy sequence for black patients and of the trabeculectomy-ALT-trabeculectomy sequence for white patients without life-threatening health problems. The choice of treatment should take into account individual patient characteristics and needs.
38 CFR 4.75 - General considerations for evaluating visual impairment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...
38 CFR 4.75 - General considerations for evaluating visual impairment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...
38 CFR 4.75 - General considerations for evaluating visual impairment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...
NASA Astrophysics Data System (ADS)
Banesh, D.; Oskin, M. E.; Mu, A.; Vu, C.; Westerteiger, R.; Krishnan, A.; Hamann, B.; Glennie, C. L.; Hinojosa, A.; Borsa, A. A.
2013-12-01
Differential LiDAR provides unprecedented images of the near-field ground deformation and fault slip due to earthquakes. Here we examine the performance of the Iterative Closest Point (ICP) technique for data registration between pre- and post-earthquake LiDAR point clouds of varying density. We use the 2010 El Mayor-Cucapah data set as our region of interest since this earthquake produced different types of surface ruptures, yielding a variety of deformation styles for analysis. We also test a more simplistic, Chi-Squared minimization approach and find that it produces good results when compared to ICP. We present different techniques for visualizing large vector fields, and show how each method highlights a unique feature in the data set. Dense vector fields are useful when analyzing smaller deformations in the surface. A sparse, averaged vector field analyzes the bigger, overall shifts without interference caused by small details. Flow-based visualizations like Line Integral Convolution (LIC) graphs, provide insight into particular artifacts of data collection, such as distortions due to uncorrected pitch and yaw of the aircraft during the survey. Animations of the vector field establish the direction of movement in the landscape, quickly highlighting areas of interest.
Beltran, Eduardo J.; Dingwell, Jonathan B.; Wilken, Jason M.
2014-01-01
Understanding how lower-limb amputation affects walking stability, specifically in destabilizing environments, is essential for developing effective interventions to prevent falls. This study quantified mediolateral margins of stability (MOS) and MOS sub-components in young individuals with traumatic unilateral transtibial amputation (TTA) and young able-bodied individuals (AB). Thirteen AB and nine TTA completed five 3-minute walking trials in a Computer Assisted Rehabilitation ENvironment (CAREN) system under three each of three test conditions: no perturbations, pseudo-random mediolateral translations of the platform, and pseudo-random mediolateral translations of the visual field. Compared to the unperturbed trials, TTA exhibited increased mean MOS and MOS variability during platform and visual field perturbations (p < 0.010). Also, AB exhibited increased mean MOS during visual field perturbations and increased MOS variability during both platform and visual field perturbations (p < 0.050). During platform perturbations, TTA exhibited significantly greater values than AB for mean MOS (p < 0.050) and MOS variability (p < 0.050); variability of the lateral distance between the center of mass (COM) and base of support at initial contact (p < 0.005); mean and variability of the range of COM motion (p < 0.010); and variability of COM peak velocity (p < 0.050). As determined by mean MOS and MOS variability, young and otherwise healthy individuals with transtibial amputation achieved stability similar to that of their able-bodied counterparts during unperturbed and visually-perturbed walking. However, based on mean and variability of MOS, unilateral transtibial amputation was shown to have affected walking stability during platform perturbations. PMID:24444777
Zamba, Gideon K. D.; Artes, Paul H.
2018-01-01
Purpose It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect of censoring on mean deviation (MD). Methods In the Iowa Variability in Perimetry Study, 120 glaucoma subjects were tested every 6 months for 4 years with size III SITA Standard and size V Full Threshold. Progression was determined with three complementary techniques: pointwise linear regression (PLR), permutation of PLR, and linear regression of the MD index. All analyses were repeated on “censored'' datasets in which threshold estimates below a given criterion value were set to equal the criterion value. Results Our analyses confirmed previous observations that threshold estimates below 20 dB contribute much less to visual field progression than estimates above this range. These findings were broadly similar with stimulus sizes III and V. Conclusions Censoring of threshold values < 20 dB has relatively little impact on the rates of visual field progression in patients with mild to moderate glaucoma. Size V, which has lower retest variability, performs at least as well as size III for longitudinal glaucoma progression analysis and appears to have a larger useful dynamic range owing to the upper sensitivity limit being higher. PMID:29356822
NASA Technical Reports Server (NTRS)
Everhart, Joel L.; Ashby, George C., Jr.; Monta, William J.
1992-01-01
A propulsion/airframe integration experiment conducted in the NASA Langley 20-Inch Mach 6 Tunnel using a 16.8-in.-long version of the Langley Test Technique Demonstrator configuration with simulated scramjet propulsion is described. Schlieren and vapor screen visualization of the nozzle flow field is presented and correlated with pitot-pressure flow-field surveys. The data were obtained at nominal free-stream conditions of Re = 2.8 x 10 exp 6 and a nominal engine total pressure of 100 psia. It is concluded that pitot-pressure surveys coupled to schlieren and vapor-screen photographs, and oil flows have revealed flow features including vortices, free shear layers, and shock waves occurring in the model flow field.
Multifield-graphs: an approach to visualizing correlations in multifield scalar data.
Sauber, Natascha; Theisel, Holger; Seidel, Hans-Peter
2006-01-01
We present an approach to visualizing correlations in 3D multifield scalar data. The core of our approach is the computation of correlation fields, which are scalar fields containing the local correlations of subsets of the multiple fields. While the visualization of the correlation fields can be done using standard 3D volume visualization techniques, their huge number makes selection and handling a challenge. We introduce the Multifield-Graph to give an overview of which multiple fields correlate and to show the strength of their correlation. This information guides the selection of informative correlation fields for visualization. We use our approach to visually analyze a number of real and synthetic multifield datasets.
Spatial attention does not require preattentive grouping.
Vecera, S P; Behrmann, M
1997-01-01
Does spatial attention follow a full preattentive analysis of the visual field, or can attention select from ungrouped regions of the visual field? We addressed this question by testing an apperceptive agnosic patient, J. W., in tasks involving both spatial selection and preattentive grouping. Results suggest that J.W. had intact spatial attention: He was faster to detect targets appearing at cued location relative to targets appearing at uncued locations. However, his preattentive processes were severely disrupted. Gestalt grouping and symmetry perception, both thought to involve preattentive processes, were impaired in J. W. Also, he could not use gestalt grouping cues to guide spatial attention. These results suggest that spatial attention is not completely dependent on preattentive grouping processes. We argue that preattentive grouping processes and spatial attention may mutually constrain one another in guiding the attentional selection of visual stimuli but that these 2 processes are isolated from one another.
ERIC Educational Resources Information Center
Evans, Karen M.; Federmeier, Kara D.
2009-01-01
Hemispheric differences in the use of memory retrieval cues were examined in a continuous recognition design, using visual half-field presentation to bias the processing of test words. A speeded recognition task revealed general accuracy and response time advantages for items whose test presentation was biased to the left hemisphere. A second…
ERIC Educational Resources Information Center
Curtis, W. Scott
The purpose of this project was to inquire into the current status of development, past use, availability, and future planning of intelligence tests for the visually handicapped in relation to the fields of psychological, educational, and vocational counseling. The project procedure was that of a research utilization conference involving the…
Kawa, P; Mańkowska, A; Mackiewicz, J; Zagórski, Z
1998-01-01
The purpose of this study is the present clinical evaluation of 21 patients (number of affected eyes--33), who watched eclipse of the sun on 12 October 1996. All patients had general ophthalmic examination with emphasis on visual acuity, visual field, Amsler test, fluorescein angiography and fundus appearance. Eleven out of 21 patients had at least one follow up examination (number of affected eyes--17). None of the patient received any treatment. All patients revealed tiny, central scotomata--positive Amsler test and decreased visual acuity on the first visit; reading Snellen chart could be improved in all patients by adequate head tilt or eye movement (improvement up to 3 Snellen chart lines). No signs of retinopathy were observed in two eyes with uncorrected refractive error and one amblyopic eye. After 7-8 weeks the visual acuity was decreased to 5/30 in two eyes and to 5/10 in ten eyes. In all those eyes persisted a tiny, central scotoma. Looking at the eclipse of the sun in spite of using primitive eye protection may cause irreversible retinal damage. Return of visual acuity to 5/5 does not always imply complete recovery because of persistent central scotoma.
Welbourne, Lauren E; Morland, Antony B; Wade, Alex R
2018-02-15
The spatial sensitivity of the human visual system depends on stimulus color: achromatic gratings can be resolved at relatively high spatial frequencies while sensitivity to isoluminant color contrast tends to be more low-pass. Models of early spatial vision often assume that the receptive field size of pattern-sensitive neurons is correlated with their spatial frequency sensitivity - larger receptive fields are typically associated with lower optimal spatial frequency. A strong prediction of this model is that neurons coding isoluminant chromatic patterns should have, on average, a larger receptive field size than neurons sensitive to achromatic patterns. Here, we test this assumption using functional magnetic resonance imaging (fMRI). We show that while spatial frequency sensitivity depends on chromaticity in the manner predicted by behavioral measurements, population receptive field (pRF) size measurements show no such dependency. At any given eccentricity, the mean pRF size for neuronal populations driven by luminance, opponent red/green and S-cone isolating contrast, are identical. Changes in pRF size (for example, an increase with eccentricity and visual area hierarchy) are also identical across the three chromatic conditions. These results suggest that fMRI measurements of receptive field size and spatial resolution can be decoupled under some circumstances - potentially reflecting a fundamental dissociation between these parameters at the level of neuronal populations. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Flow visualization techniques in the Airborne Laser Laboratory program
NASA Technical Reports Server (NTRS)
Walterick, R. E.; Vankuren, J. T.
1980-01-01
A turret/fairing assembly for laser applications was designed and tested. Wind tunnel testing was conducted using flow visualization techniques. The techniques used have included the methods of tufting, encapsulated liquid crystals, oil flow, sublimation and schlieren and shadowgraph photography. The results were directly applied to the design of fairing shapes for minimum drag and reduced turret buffet. In addition, the results are of primary importance to the study of light propagation paths in the near flow field of the turret cavity. Results indicate that the flow in the vicinity of the turret is an important factor for consideration in the design of suitable turret/fairing or aero-optic assemblies.
Freeman, William R.; Van Natta, Mark L.; Jabs, Douglas; Sample, Pamela A.; Sadun, Alfredo A.; Thorne, Jennifer; Shah, Kayur H.; Holland, Gary N.
2008-01-01
Purpose To evaluate the prevalence and risk factors for vision loss in patients with clinical or immunologic AIDS without infectious retinitis. Design A prospective multicentered cohort study of patients with AIDS. Methods 1,351 patients (2,671 eyes) at 19 clinical trials centers diagnosed with AIDS but without major ocular complications of HIV. Standardized measurements of visual acuity, automated perimetry, and contrast sensitivity were analyzed and correlated with measurements of patients’ health and medical data relating to HIV infection. We evaluated correlations between vision function testing and HIV-related risk factors and medical testing. Results There were significant (p<0.05) associations between measures of decreasing vision function and indices of increasing disease severity including Karnofsky score and hemoglobin. A significant relationship was seen between low contrast sensitivity and decreasing levels of CD4+ T-cell count. Three percent of eyes had a visual acuity worse than 20/40 Snellen equivalents, which was significantly associated with a history of opportunistic infections and low Karnofsky score. When compared to external groups with normal vision, 39% of eyes had abnormal mean deviation on automated perimetry, 33% had abnormal pattern standard deviation, and 12% of eyes had low contrast sensitivity. Conclusions This study confirms that visual dysfunction is common in patients with AIDS but without retinitis. The most prevalent visual dysfunction is loss of visual field; nearly 40% of patients have some abnormal visual field. There is an association between general disease severity and less access to care and vision loss. The pathophysiology of this vision loss is unknown but is consistent with retinovascular disease or optic nerve disease. PMID:18191094
Maass, Johanna; Matthé, Egbert
2018-04-01
Leber's hereditary optic neuropathy is relatively rare, and no clinical pathognomonic signs exist. We present a rare case of bilateral vision loss of a patient with multiple drug abuse in the history. A 31-year-old man presented with a history of progressive, decreased vision in both eyes for 6 month. On examination, his visual acuity was hand motion in both eyes. Funduscopy demonstrated a temporal pallor of the optic disc. Goldmann visual field perimetry showed a crescent visual field in the right eye and a circular decrease to less than 50 ° in the left eye. Electroretinogram showed a scotopic b-wave amplitude reduction. Optical coherence tomographies, Heidelberg Retina tomography, visual evoked potentials, and magnetic resonance imaging with contrast as well as blood tests were normal. The patient reported to consume various kinds of drugs as well as recreational drug use and alcohol consumption since he was 16 years old. We started a hemodilution therapy, believing the patient suffered from a bilateral, toxic optic neuropathy due to his lifestyle. Laboratory results later on showed Leber's hereditary optic neuropathy. Leber's hereditary optic neuropathy is a rare disease without a typical, pathognomonic presentation. Even though the patient gave good reasons for a toxic optic neuropathy, one should never stop to test for other diseases.
Serial dependence promotes object stability during occlusion
Liberman, Alina; Zhang, Kathy; Whitney, David
2016-01-01
Object identities somehow appear stable and continuous over time despite eye movements, disruptions in visibility, and constantly changing visual input. Recent results have demonstrated that the perception of orientation, numerosity, and facial identity is systematically biased (i.e., pulled) toward visual input from the recent past. The spatial region over which current orientations or face identities are pulled by previous orientations or identities, respectively, is known as the continuity field, which is temporally tuned over the past several seconds (Fischer & Whitney, 2014). This perceptual pull could contribute to the visual stability of objects over short time periods, but does it also address how perceptual stability occurs during visual discontinuities? Here, we tested whether the continuity field helps maintain perceived object identity during occlusion. Specifically, we found that the perception of an oriented Gabor that emerged from behind an occluder was significantly pulled toward the random (and unrelated) orientation of the Gabor that was seen entering the occluder. Importantly, this serial dependence was stronger for predictable, continuously moving trajectories, compared to unpredictable ones or static displacements. This result suggests that our visual system takes advantage of expectations about a stable world, helping to maintain perceived object continuity despite interrupted visibility. PMID:28006066
Anosognosia for obvious visual field defects in stroke patients.
Baier, Bernhard; Geber, Christian; Müller-Forell, Wiebke; Müller, Notger; Dieterich, Marianne; Karnath, Hans-Otto
2015-01-01
Patients with anosognosia for visual field defect (AVFD) fail to recognize consciously their visual field defect. There is still unclarity whether specific neural correlates are associated with AVFD. We studied AVFD in 54 patients with acute stroke and a visual field defect. Nineteen percent of this unselected sample showed AVFD. By using modern voxelwise lesion-behaviour mapping techniques we found an association between AVFD and parts of the lingual gyrus, the cuneus as well as the posterior cingulate and corpus callosum. Damage to these regions appears to induce unawareness of visual field defects and thus may play a significant role for conscious visual perception.
Pituitary apoplexy in a teenager--case report.
Chao, Chen-Cheng; Lin, Chun-Ju
2014-06-01
Pituitary apoplexy is a rare clinical emergency which results from hemorrhage or infarction in the pituitary gland. We present a 14-year-old girl with pituitary apoplexy and review the literature. Our patient experienced blurred vision, nausea, and headache. Her best-corrected visual acuity was 20/200 and 20/20. Confrontation test visual field testing revealed bitemporal hemianopsia. Brain imaging demonstrated a suprasellar mass. The microscopic endonasal transsphenoidal approach only found 5-10 mL brownish fluid-like material. Pathology confirmed no malignancy. Pituitary apoplexy was diagnosed. Her nausea and headache gradually improved. Six months after operation, her best-corrected visual acuity had improved to 20/30 and 20/20. Although pituitary apoplexy is rare in pediatric patients, prompt evaluation including detailed ophthalmic examination, biochemical evaluation, endocrine workup, and image study are very important. Copyright © 2014 Elsevier Inc. All rights reserved.
Agnosic vision is like peripheral vision, which is limited by crowding.
Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa
2017-04-01
Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it urgent to know what drives crowding. Acuity does not (Song et al., 2014), but neural density might: neurons per deg 2 in the crowding-relevant cortical area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Huang, Liqiang; Mo, Lei; Li, Ying
2012-04-01
A large part of the empirical research in the field of visual attention has focused on various concrete paradigms. However, as yet, there has been no clear demonstration of whether or not these paradigms are indeed measuring the same underlying construct. We collected a very large data set (nearly 1.3 million trials) to address this question. We tested 257 participants on nine paradigms: conjunction search, configuration search, counting, tracking, feature access, spatial pattern, response selection, visual short-term memory, and change blindness. A fairly general attention factor was identified. Some of the participants were also tested on eight other paradigms. This general attention factor was found to be correlated with intelligence, visual marking, task switching, mental rotation, and Stroop task. On the other hand, a few paradigms that are very important in the attention literature (attentional capture, consonance-driven orienting, and inhibition of return) were found to be dissociated from this general attention factor.
Kleiter, Ingo; Luerding, Ralf; Diendorfer, Gerhard; Rek, Helga; Bogdahn, Ulrich; Schalke, Berthold
2007-01-01
The case of a 23‐year‐old mountaineer who was hit by a lightning strike to the occiput causing a large central visual field defect and bilateral tympanic membrane ruptures is described. Owing to extreme agitation, the patient was set to a drug‐induced coma for 3 days. After extubation, she experienced simple and complex visual hallucinations for several days, but otherwise recovered largely. Neuropsychological tests revealed deficits in fast visual detection tasks and non‐verbal learning, and indicated a right temporal lobe dysfunction, consistent with a right temporal focus on electroencephalography. Four months after the accident, she developed a psychological reaction consisting of nightmares with reappearance of the complex visual hallucinations and a depressive syndrome. Using the European Cooperation for Lightning Detection network, a meteorological system for lightning surveillance, the exact geographical location and nature of the lightning flash were retrospectively retraced. PMID:17369595
Kleiter, Ingo; Luerding, Ralf; Diendorfer, Gerhard; Rek, Helga; Bogdahn, Ulrich; Schalke, Berthold
2009-01-01
The case of a 23-year-old mountaineer who was hit by a lightning strike to the occiput causing a large central visual field defect and bilateral tympanic membrane ruptures is described. Owing to extreme agitation, the patient was sent into a drug-induced coma for 3 days. After extubation, she experienced simple and complex visual hallucinations for several days, but otherwise largely recovered. Neuropsychological tests revealed deficits in fast visual detection tasks and non-verbal learning and indicated a right temporal lobe dysfunction, consistent with a right temporal focus on electroencephalography. At 4 months after the accident, she developed a psychological reaction consisting of nightmares, with reappearance of the complex visual hallucinations and a depressive syndrome. Using the European Cooperation for Lightning Detection network, a meteorological system for lightning surveillance, the exact geographical location and nature of the lightning strike were retrospectively retraced PMID:21734915
Harvey, Ben M; Dumoulin, Serge O
2016-02-15
Several studies demonstrate that visual stimulus motion affects neural receptive fields and fMRI response amplitudes. Here we unite results of these two approaches and extend them by examining the effects of visual motion on neural position preferences throughout the hierarchy of human visual field maps. We measured population receptive field (pRF) properties using high-field fMRI (7T), characterizing position preferences simultaneously over large regions of the visual cortex. We measured pRFs properties using sine wave gratings in stationary apertures, moving at various speeds in either the direction of pRF measurement or the orthogonal direction. We find direction- and speed-dependent changes in pRF preferred position and size in all visual field maps examined, including V1, V3A, and the MT+ map TO1. These effects on pRF properties increase up the hierarchy of visual field maps. However, both within and between visual field maps the extent of pRF changes was approximately proportional to pRF size. This suggests that visual motion transforms the representation of visual space similarly throughout the visual hierarchy. Visual motion can also produce an illusory displacement of perceived stimulus position. We demonstrate perceptual displacements using the same stimulus configuration. In contrast to effects on pRF properties, perceptual displacements show only weak effects of motion speed, with far larger speed-independent effects. We describe a model where low-level mechanisms could underlie the observed effects on neural position preferences. We conclude that visual motion induces similar transformations of visuo-spatial representations throughout the visual hierarchy, which may arise through low-level mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.
Visualizing second order tensor fields with hyperstreamlines
NASA Technical Reports Server (NTRS)
Delmarcelle, Thierry; Hesselink, Lambertus
1993-01-01
Hyperstreamlines are a generalization to second order tensor fields of the conventional streamlines used in vector field visualization. As opposed to point icons commonly used in visualizing tensor fields, hyperstreamlines form a continuous representation of the complete tensor information along a three-dimensional path. This technique is useful in visulaizing both symmetric and unsymmetric three-dimensional tensor data. Several examples of tensor field visualization in solid materials and fluid flows are provided.
Peripheral resolution and contrast sensitivity: Effects of stimulus drift.
Venkataraman, Abinaya Priya; Lewis, Peter; Unsbo, Peter; Lundström, Linda
2017-04-01
Optimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This study evaluates the characteristics of the peripheral spatiotemporal contrast sensitivity function in normal-sighted subjects. The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss. High contrast resolution cut-off for grating stimuli with four temporal frequencies (0, 5, 10 and 15Hz drift) was first evaluated in the 10° nasal visual field. Resolution contrast sensitivity for all temporal frequencies was then measured at four spatial frequencies between 0.5 cycles per degree (cpd) and the measured stationary cut-off. All measurements were performed with eccentric optical correction. Similar to foveal vision, peripheral contrast sensitivity is highest for a combination of low spatial frequency and 5-10Hz drift. At higher spatial frequencies, there was a decrease in contrast sensitivity with 15Hz drift. Despite this decrease, the resolution cut-off did not vary largely between the different temporal frequencies tested. Additional measurements of contrast sensitivity at 0.5 cpd and resolution cut-off for stationary (0Hz) and 7.5Hz stimuli performed at 10, 15, 20 and 25° in the nasal visual field also showed the same characteristics across eccentricities. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsao, Thomas R.; Tsao, Doris
1997-04-01
In the 1980's, neurobiologist suggested a simple mechanism in primate visual cortex for maintaining a stable and invariant representation of a moving object. The receptive field of visual neurons has real-time transforms in response to motion, to maintain a stable representation. When the visual stimulus is changed due to motion, the geometric transform of the stimulus triggers a dual transform of the receptive field. This dual transform in the receptive fields compensates geometric variation in the stimulus. This process can be modelled using a Lie group method. The massive array of affine parameter sensing circuits will function as a smart sensor tightly coupled to the passive imaging sensor (retina). Neural geometric engine is a neuromorphic computing device simulating our Lie group model of spatial perception of primate's primal visual cortex. We have developed the computer simulation and experimented on realistic and synthetic image data, and performed a preliminary research of using analog VLSI technology for implementation of the neural geometric engine. We have benchmark tested on DMA's terrain data with their result and have built an analog integrated circuit to verify the computational structure of the engine. When fully implemented on ANALOG VLSI chip, we will be able to accurately reconstruct a 3D terrain surface in real-time from stereoscopic imagery.
Visual brain plasticity induced by central and peripheral visual field loss.
Sanda, Nicolae; Cerliani, Leonardo; Authié, Colas N; Sabbah, Norman; Sahel, José-Alain; Habas, Christophe; Safran, Avinoam B; Thiebaut de Schotten, Michel
2018-06-23
Disorders that specifically affect central and peripheral vision constitute invaluable models to study how the human brain adapts to visual deafferentation. We explored cortical changes after the loss of central or peripheral vision. Cortical thickness (CoTks) and resting-state cortical entropy (rs-CoEn), as a surrogate for neural and synaptic complexity, were extracted in 12 Stargardt macular dystrophy, 12 retinitis pigmentosa (tunnel vision stage), and 14 normally sighted subjects. When compared to controls, both groups with visual loss exhibited decreased CoTks in dorsal area V3d. Peripheral visual field loss also showed a specific CoTks decrease in early visual cortex and ventral area V4, while central visual field loss in dorsal area V3A. Only central visual field loss exhibited increased CoEn in LO-2 area and FG1. Current results revealed biomarkers of brain plasticity within the dorsal and the ventral visual streams following central and peripheral visual field defects.
Kim, Jonghyeon; Dally, Leonard G; Ederer, Fred; Gaasterland, Douglas E; VanVeldhuisen, Paul C; Blackwell, Beth; Sullivan, E Kenneth; Prum, Bruce; Shafranov, George; Beck, Allen; Spaeth, George L
2004-11-01
To determine the least worsening of a visual field (VF) and the least number of confirming tests needed to identify progression of glaucomatous VF defects. Cohort study of participants in a clinical trial. Seven hundred fifty-two eyes of 565 patients with advanced glaucoma. Visual field tests were quantified with the Advanced Glaucoma Intervention Study (AGIS) VF defect score and the Humphrey Field Analyzer mean deviation (MD). Follow-up was 8 to 13 years. Two measures based on the AGIS VF defect score: (1) sustained decrease of VF (SDVF), a worsening from baseline by 2 (alternatively, 3 or 4) or more units and sustained for 2 (alternatively, 3) consecutive 6-month visits and (2) after the occurrence of SDVF, the average percent of eyes with worsening by 2 (alternatively, 3 or 4) or more units from baseline. Two similar measures based on MD. Based on the original AGIS criteria for SDVF (a worsening of 4 units in the AGIS score sustained during 3 consecutive 6-month visits), 31% of eyes had an SDVF. The percent of eyes with a sustained event increases by approximately 10% when either the minimum number of units of field loss or the minimum number of 6-month visits during which the loss is sustained decreases by 1. During 3 years of follow-up after a sustained event, a worsening of at least 2 units was found in 72% of eyes that had a 2-visit sustained event. The same worsening was found in 84% of eyes that had a 3-visit sustained event. Through the next 10 years after a sustained event, based on worsening of 2, 3, or 4 units at 2 or 3 consecutive tests, the loss reoccurred, on average, in >/=75% of study eyes. Results for MD are similar. In patients with advanced glaucoma, a single confirmatory test 6 months after a VF worsening indicates with at least 72% probability a persistent defect when the worsening is defined by at least 2 units of AGIS score or by at least 2 decibels of MD. When the number of confirmatory tests is increased from 1 to 2, the percentage of eyes that show a persistent defect increases from 72% to 84%.
Predictors of driving safety in early Alzheimer disease
Dawson, J D.; Anderson, S W.; Uc, E Y.; Dastrup, E; Rizzo, M
2009-01-01
Objective: To measure the association of cognition, visual perception, and motor function with driving safety in Alzheimer disease (AD). Methods: Forty drivers with probable early AD (mean Mini-Mental State Examination score 26.5) and 115 elderly drivers without neurologic disease underwent a battery of cognitive, visual, and motor tests, and drove a standardized 35-mile route in urban and rural settings in an instrumented vehicle. A composite cognitive score (COGSTAT) was calculated for each subject based on eight neuropsychological tests. Driving safety errors were noted and classified by a driving expert based on video review. Results: Drivers with AD committed an average of 42.0 safety errors/drive (SD = 12.8), compared to an average of 33.2 (SD = 12.2) for drivers without AD (p < 0.0001); the most common errors were lane violations. Increased age was predictive of errors, with a mean of 2.3 more errors per drive observed for each 5-year age increment. After adjustment for age and gender, COGSTAT was a significant predictor of safety errors in subjects with AD, with a 4.1 increase in safety errors observed for a 1 SD decrease in cognitive function. Significant increases in safety errors were also found in subjects with AD with poorer scores on Benton Visual Retention Test, Complex Figure Test-Copy, Trail Making Subtest-A, and the Functional Reach Test. Conclusion: Drivers with Alzheimer disease (AD) exhibit a range of performance on tests of cognition, vision, and motor skills. Since these tests provide additional predictive value of driving performance beyond diagnosis alone, clinicians may use these tests to help predict whether a patient with AD can safely operate a motor vehicle. GLOSSARY AD = Alzheimer disease; AVLT = Auditory Verbal Learning Test; Blocks = Block Design subtest; BVRT = Benton Visual Retention Test; CFT = Complex Figure Test; CI = confidence interval; COWA = Controlled Oral Word Association; CS = contrast sensitivity; FVA = far visual acuity; JLO = Judgment of Line Orientation; MCI = mild cognitive impairment; MMSE = Mini-Mental State Examination; NVA = near visual acuity; SFM = structure from motion; TMT = Trail-Making Test; UFOV = Useful Field of View. PMID:19204261
Visual Agnosia and Posterior Cerebral Artery Infarcts: An Anatomical-Clinical Study
Martinaud, Olivier; Pouliquen, Dorothée; Gérardin, Emmanuel; Loubeyre, Maud; Hirsbein, David; Hannequin, Didier; Cohen, Laurent
2012-01-01
Background To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA) strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. Methods and Findings We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct) with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA), faces (FFA and OFA), houses (PPA) and common objects (LOC). Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words). Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. Conclusions Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations. PMID:22276198
Visual agnosia and posterior cerebral artery infarcts: an anatomical-clinical study.
Martinaud, Olivier; Pouliquen, Dorothée; Gérardin, Emmanuel; Loubeyre, Maud; Hirsbein, David; Hannequin, Didier; Cohen, Laurent
2012-01-01
To evaluate systematically the cognitive deficits following posterior cerebral artery (PCA) strokes, especially agnosic visual disorders, and to study anatomical-clinical correlations. We investigated 31 patients at the chronic stage (mean duration of 29.1 months post infarct) with standardized cognitive tests. New experimental tests were used to assess visual impairments for words, faces, houses, and objects. Forty-one healthy subjects participated as controls. Brain lesions were normalized, combined, and related to occipitotemporal areas responsive to specific visual categories, including words (VWFA), faces (FFA and OFA), houses (PPA) and common objects (LOC). Lesions were located in the left hemisphere in 15 patients, in the right in 13, and bilaterally in 3. Visual field defects were found in 23 patients. Twenty patients had a visual disorder in at least one of the experimental tests (9 with faces, 10 with houses, 7 with phones, 3 with words). Six patients had a deficit just for a single category of stimulus. The regions of maximum overlap of brain lesions associated with a deficit for a given category of stimuli were contiguous to the peaks of the corresponding functional areas as identified in normal subjects. However, the strength of anatomical-clinical correlations was greater for words than for faces or houses, probably due to the stronger lateralization of the VWFA, as compared to the FFA or the PPA. Agnosic visual disorders following PCA infarcts are more frequent than previously reported. Dedicated batteries of tests, such as those developed here, are required to identify such deficits, which may escape clinical notice. The spatial relationships of lesions and of regions activated in normal subjects predict the nature of the deficits, although individual variability and bilaterally represented systems may blur those correlations.
Clinical impact of migraine for the management of glaucoma patients.
Nguyen, Bao N; Lek, Jia Jia; Vingrys, Algis J; McKendrick, Allison M
2016-03-01
Migraine is a common and debilitating primary headache disorder that affects 10-15% of the general population, particularly people of working age. Migraine is relevant to providers of clinical eye-care because migraine attacks are associated with a range of visual sensory symptoms, and because of growing evidence that the results of standard tests of visual function necessary for the diagnosis and monitoring of glaucoma (visual fields, electrophysiology, ocular imaging) can be abnormal due to migraine. These abnormalities are measureable in-between migraine events (the interictal period), despite patients being asymptomatic and otherwise healthy. This picture is further complicated by epidemiological data that suggests an increased prevalence of migraine in patients with glaucoma, particularly in patients with normal tension glaucoma. We discuss how migraine, as a co-morbidity, can confound the results and interpretation of clinical tests that form part of contemporary glaucoma evaluation, and provide practical evidence-based recommendations for the clinical testing and management of patients with migraine who attend eye-care settings. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Does music influence visual perception in campimetric measurements of the visual field?].
Gall, Carolin; Geier, Jens-Stefan; Sabel, Bernhard A; Kasten, Erich
2009-01-01
21 subjects (mean age 28,4 +/- 10,9, M +/- SD) without any damage of the visual system were examined with computer-based campimetric tests of near threshold stimulus detection whereby an artificial tunnel vision was induced. Campimetry was performed in four trials in randomized order using a within-subjects-design: 1. classical music, 2. Techno music, 3. music for relaxation and 4. no music. Results were slightly better in all music conditions. Performance was best when subjects were listening to Techno music. The average increase of correctly recognized stimuli and fixation controls amounted to 3 %. To check the stability of the effects 9 subjects were tested three times. A moderating influence of personality traits and habits of listening to music was tested but could not be found. We conclude that music has at least no negative influence on performance in the campimetric measurement. Reasons for the positive effects of music can be seen in a general increase of vigilance and a modulation of perceptual thresholds.
Reifman, Jaques; Kumar, Kamal; Khitrov, Maxim Y; Liu, Jianbo; Ramakrishnan, Sridhar
2018-07-01
The psychomotor vigilance task (PVT) has been widely used to assess the effects of sleep deprivation on human neurobehavioral performance. To facilitate research in this field, we previously developed the PC-PVT, a freely available software system analogous to the "gold-standard" PVT-192 that, in addition to allowing for simple visual reaction time (RT) tests, also allows for near real-time PVT analysis, prediction, and visualization in a personal computer (PC). Here we present the PC-PVT 2.0 for Windows 10 operating system, which has the capability to couple PVT tests of a study protocol with the study's sleep/wake and caffeine schedules, and make real-time individualized predictions of PVT performance for such schedules. We characterized the accuracy and precision of the software in measuring RT, using 44 distinct combinations of PC hardware system configurations. We found that 15 system configurations measured RTs with an average delay of less than 10 ms, an error comparable to that of the PVT-192. To achieve such small delays, the system configuration should always use a gaming mouse as the means to respond to visual stimuli. We recommend using a discrete graphical processing unit for desktop PCs and an external monitor for laptop PCs. This update integrates a study's sleep/wake and caffeine schedules with the testing software, facilitating testing and outcome visualization, and provides near-real-time individualized PVT predictions for any sleep-loss condition considering caffeine effects. The software, with its enhanced PVT analysis, visualization, and prediction capabilities, can be freely downloaded from https://pcpvt.bhsai.org. Published by Elsevier B.V.
Microsurgical Resection of Lateral Tuberculum Sellae Meningioma: Operative Video.
Cândido, Duarte N C; Nakashima, Paulo E H; de Oliveira, Jean Gonçalves; Borba, Luis A B
2018-02-01
Tuberculum Sellae Meningiomas (TSMs) are lesions dramatically related to the optic apparatus once the principal clinical complain remains on visual alterations. This is the main picture on decision making to evaluate the best time, risk-benefit, and surgical approaches to the patient treatment. In this video, we present a 65 years old female with 30 days complaint of unilateral (right) complete blindness and complete impaired right eye field test. On physical examination, there were normal pupillary function to light tests. The scans demonstrated the presence of a TSM mostly related to the right optic nerve and encasing it altogether with the right internal carotid artery. Promptly, surgery was addressed using a modified one piece cranio-orbital-zygomatic approach with extra-dural anterior clinoidectomy, as this is the procedure of choice of the senior author (LB), with easy access to decompression of the optic canal and nerve. As demonstrated on the video, the optic nerve was encased by the tumor and pushed upwards against the falciform ligament. Complete resection and decompression was established with step by step dissection, starting unroofing the optic canal, opening the ligament and finally with carefully tumor debulking. Pathology demonstrated a grade one meningioma. The patient improved remarkably her visual acuity and visual field tests on the postoperative period, emphasizing the importance of early treatment for nerve function outcome. The link to the video can be found at: https://youtu.be/pALZqDUkltQ .
Effects of olanzapine, sertindole and clozapine on MK-801 induced visual memory deficits in mice.
Mutlu, Oguz; Ulak, Güner; Celikyurt, Ipek Komsuoglu; Akar, Füruzan Yildiz; Erden, Faruk; Tanyeri, Pelin
2011-10-01
We investigated the effects of the second generation antipsychotics olanzapine, sertindole and clozapine on visual recognition memory using the novel object recognition (NOR) test in naive and MK-801-treated animals. The effects of drug treatment on locomotion and anxiety were also determined using the open field test. Male Balb-c mice were treated with olanzapine (0.2, 0.4 and 0.6 mg/kg; i.p.), sertindole (0.63, 1.3 and 2.5mg/kg; s.c.) or clozapine (0.5 and 1mg/kg; i.p.), and cognitive deficits were induced by MK-801 (0.2mg/kg; i.p.) administration. Olanzapine treatment decreased the ratio index in the NOR test, whereas sertindole and clozapine had no effect in naive mice. MK-801-induced cognitive impairment was reversed by treatment with olanzapine, sertindole or clozapine. While olanzapine, sertindole and clozapine had no effect on the anxiety of naive mice as determined by the open field test, MK-801 significantly increased the total distance traveled, time spent in the center zone and the velocity of the animals. MK-801-induced effects on locomotion and anxiety in the open field test were reversed by olanzapine, sertindole or clozapine treatment. The results of the present study demonstrated that olanzapine, sertindole and clozapine improved cognition in MK-801 treated mice, and indicate that these drugs have a potential to improve cognition in schizophrenia. Copyright © 2011 Elsevier Inc. All rights reserved.
Visual Attention Measures Predict Pedestrian Detection in Central Field Loss: A Pilot Study
Alberti, Concetta F.; Horowitz, Todd; Bronstad, P. Matthew; Bowers, Alex R.
2014-01-01
Purpose The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT) and static attention (Useful Field of View; UFOV) were predictive of the ability of people with central field loss (CFL) to detect pedestrian hazards in simulated driving. Methods 11 people with bilateral CFL (visual acuity 20/30-20/200) and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT) and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests). Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision). Results UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse) (84% and 97%, respectively; p = 0.001). For CFL participants, higher proportions of timely reactions correlated significantly with higher (better) MOT speed thresholds (r = 0.73, p = 0.01), with better performance on the UFOV divided and selective attention subtests (r = −0.66 and −0.62, respectively, p<0.04), with better contrast sensitivity scores (r = 0.54, p = 0.08) and smaller scotomas (r = −0.60, p = 0.05). Conclusions Our results suggest that brief laboratory-based tests of visual attention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks. PMID:24558495
Visual attention measures predict pedestrian detection in central field loss: a pilot study.
Alberti, Concetta F; Horowitz, Todd; Bronstad, P Matthew; Bowers, Alex R
2014-01-01
The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT) and static attention (Useful Field of View; UFOV) were predictive of the ability of people with central field loss (CFL) to detect pedestrian hazards in simulated driving. 11 people with bilateral CFL (visual acuity 20/30-20/200) and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT) and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests). Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision). UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse) (84% and 97%, respectively; p = 0.001). For CFL participants, higher proportions of timely reactions correlated significantly with higher (better) MOT speed thresholds (r = 0.73, p = 0.01), with better performance on the UFOV divided and selective attention subtests (r = -0.66 and -0.62, respectively, p<0.04), with better contrast sensitivity scores (r = 0.54, p = 0.08) and smaller scotomas (r = -0.60, p = 0.05). Our results suggest that brief laboratory-based tests of visual attention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks.
Mödden, Claudia; Behrens, Marion; Damke, Iris; Eilers, Norbert; Kastrup, Andreas; Hildebrandt, Helmut
2012-06-01
Compensatory and restorative treatments have been developed to improve visual field defects after stroke. However, no controlled trials have compared these interventions with standard occupational therapy (OT). A total of 45 stroke participants with visual field defect admitted for inpatient rehabilitation were randomized to restorative computerized training (RT) using computer-based stimulation of border areas of their visual field defects or to a computer-based compensatory therapy (CT) teaching a visual search strategy. OT, in which different compensation strategies were used to train for activities of daily living, served as standard treatment for the active control group. Each treatment group received 15 single sessions of 30 minutes distributed over 3 weeks. The primary outcome measures were visual field expansion for RT, visual search performance for CT, and reading performance for both treatments. Visual conjunction search, alertness, and the Barthel Index were secondary outcomes. Compared with OT, CT resulted in a better visual search performance, and RT did not result in a larger expansion of the visual field. Intragroup pre-post comparisons demonstrated that CT improved all defined outcome parameters and RT several, whereas OT only improved one. CT improved functional deficits after visual field loss compared with standard OT and may be the intervention of choice during inpatient rehabilitation. A larger trial that includes lesion location in the analysis is recommended.
ERIC Educational Resources Information Center
Hunter, Zoe R.; Brysbaert, Marc
2008-01-01
Traditional neuropsychology employs visual half-field (VHF) experiments to assess cerebral language dominance. This approach is based on the assumption that left cerebral dominance for language leads to faster and more accurate recognition of words in the right visual half-field (RVF) than in the left visual half-field (LVF) during tachistoscopic…
Treatment by rituximab on six Grave's ophthalmopathies resistant to corticosteroids.
Précausta, Flavien; Arsène, Sophie; Renoult-Pierre, Peggy; Laure, Boris; Crinière, Lise; Pisella, Pierre-Jean
2017-02-01
Graves' ophthalmopathy occurs in 50% of Graves' disease cases. Treatment is based on smoking cessation, and control of the euthyroidism and ocular repercussions associated with the disease. The active orbital forms are treated with glucocorticoids. Non-validated therapies have also been recently tested. Rituximab has been effectively used several times to treat corticosteroid-resistant Graves' ophthalmopathy associated with an optic neuropathy, but its use could be proposed only in inflammatory ophthalmopathies after failure of the corticosteroids. We present six cases treated since early 2012 at the University Hospital Center of Tours, France. Six patients were treated at the University Hospital Center of Tours, France, between September 2012 and April 2014. The patients had a Mourits' score greater than three after treatment with corticosteroids and/or a severe NOSPECS score and/or orbital inflammation resistant to maximal treatment with intravenous injections of methylprednisolone and an optic neuropathy. They twice received one gram of rituximab by slow intravenous injection two weeks apart. Efficacy was assessed by a decrease of the orbital inflammatory clinical Mourits' score, and visual acuity and visual field testing. The inflammatory score of patients improved and treatment helped to stop the progression of the sequelae due to neuropathy. The orbital inflammatory clinical score, and the visual acuity and visual field improved but orbital decompression was necessary to complete the treatment. Rituximab has been used for the treatment of active corticosteroid-resistant Graves' ophthalmopathies. We also had positive results on patients with visual threat and optic neuropathy, when combined with surgical decompression. Copyright © 2016. Published by Elsevier Masson SAS.
Driving with homonymous visual field loss: a review of the literature
Bowers, Alex R.
2016-01-01
Driving is an important rehabilitation goal for patients with homonymous field defects (HFDs); however, whether or not people with HFDs should be permitted to drive is not clear. Over the last 15 years there has been a marked increase in the number of studies evaluating the effects of HFDs on driving performance. This review of the literature provides a much-needed summary for practitioners and researchers, addressing the following topics: regulations pertaining to driving with HFDs, self-reported driving difficulties, pass rates in on-road tests, the effects of HFDs on lane position and steering stability, the effects of HFDs on scanning and detection of potential hazards, screening for potential fitness to drive, evaluating practical fitness to drive, and the efficacy of interventions to improve driving of persons with HFDs. Although there is clear evidence from on-road studies that some people with HFDs may be rated as safe to drive, others are reported to have significant deficits in skills important for safe driving including taking a lane position too close to one side of the travel lane, unstable steering and inadequate viewing (scanning) behaviors. Driving simulator studies have provided strong evidence of a wide range in compensatory scanning abilities and detection performance, despite similar amounts of visual field loss. Conventional measurements of visual field extent (in which eye movements are not permitted) do not measure such compensatory abilities and are not predictive of on-road driving performance; thus, there is a need to develop better tests to screen for visual fitness to drive of people with HFDs. We are not yet at a point where we can predict which HFD patient is likely to be a safe driver. Therefore, it seems only fair to provide an opportunity for individualized assessments of practical fitness to drive either on the road and/or in a driving simulator. PMID:27535208
Driving with homonymous visual field loss: a review of the literature.
Bowers, Alex R
2016-09-01
Driving is an important rehabilitation goal for patients with homonymous field defects (HFDs); however, whether or not people with HFDs should be permitted to drive is not clear. Over the last 15 years, there has been a marked increase in the number of studies evaluating the effects of HFDs on driving performance. This review of the literature provides a much-needed summary for practitioners and researchers, addressing the following topics: regulations pertaining to driving with HFDs, self-reported driving difficulties, pass rates in on-road tests, the effects of HFDs on lane position and steering stability, the effects of HFDs on scanning and detection of potential hazards, screening for potential fitness to drive, evaluating practical fitness to drive and the efficacy of interventions to improve driving of persons with HFDs. Although there is clear evidence from on-road studies that some people with HFDs may be rated as safe to drive, others are reported to have significant deficits in skills important for safe driving, including taking a lane position too close to one side of the travel lane, unstable steering and inadequate viewing (scanning) behaviour. Driving simulator studies have provided strong evidence of a wide range in compensatory scanning abilities and detection performance, despite similar amounts of visual field loss. Conventional measurements of visual field extent (in which eye movements are not permitted) do not measure such compensatory abilities and are not predictive of on-road driving performance. Thus, there is a need to develop better tests to screen people with HFDs for visual fitness to drive. We are not yet at a point where we can predict which HFD patient is likely to be a safe driver. Therefore, it seems only fair to provide an opportunity for individualised assessments of practical fitness to drive either on the road and/or in a driving simulator. © 2016 Optometry Australia.
Taxonomic and ad hoc categorization within the two cerebral hemispheres.
Shen, Yeshayahu; Aharoni, Bat-El; Mashal, Nira
2015-01-01
A typicality effect refers to categorization which is performed more quickly or more accurately for typical than for atypical members of a given category. Previous studies reported a typicality effect for category members presented in the left visual field/right hemisphere (RH), suggesting that the RH applies a similarity-based categorization strategy. However, findings regarding the typicality effect within the left hemisphere (LH) are less conclusive. The current study tested the pattern of typicality effects within each hemisphere for both taxonomic and ad hoc categories, using words presented to the left or right visual fields. Experiment 1 tested typical and atypical members of taxonomic categories as well as non-members, and Experiment 2 tested typical and atypical members of ad hoc categories as well as non-members. The results revealed a typicality effect in both hemispheres and in both types of categories. Furthermore, the RH categorized atypical stimuli more accurately than did the LH. Our findings suggest that both hemispheres rely on a similarity-based categorization strategy, but the coarse semantic coding of the RH seems to facilitate the categorization of atypical members.
Simultaneous density-field visualization and PIV of the Richtmyer-Meshkov instability
NASA Astrophysics Data System (ADS)
Prestridge, Katherine; Rightley, Paul; Benjamin, Robert; Kurnit, Norman; Boxx, Isaac; Vorobieff, Peter
1999-11-01
We describe a highly-detailed experimental characterization of the Richtmyer-Meshkov instability. A vertical curtain of heavy gas (SF_6) flows into the test section of an air-filled, horizontal shock tube, and the instability evolves after the passage of a Mach 1.2 shock past the curtain. The evolution of the curtain is visualized by seeding the SF6 with small (d ≈ 0.5 μm) glycol/water droplets using a modified theatrical fog generator. Because the event lasts only 1 ms and the initial conditions vary from test to test, rapid and high-resolution (both spatial and temporal) data acquisition is required in order to characterize the initial and dynamic conditions for each experimental event. A customized, frequency-doubled, burst mode Nd:YAG laser and a commercial single-pulse laser are used for the implementation of simultaneous density-field imaging and PIV diagnostics. We have provided data about flow scaling and mixing through image analysis, and PIV data gives us further quantitative physical insight into the evolution of the Richtmyer-Meshkov instability.
Visual Impairment and Intracranial Hypertension: An Emerging Spaceflight Risk
NASA Technical Reports Server (NTRS)
Taddeo, Terrance A.
2010-01-01
During recent long duration missions to the International Space Station (ISS) crewmembers have reported changes in visual acuity or visual field defects. Exams in the postflight period revealed changes to the visual system and elevated intracranial pressures. As a result, NASA Space Medicine has added a number of tests to be performed in the preflight, inflight and postflight periods for ISS and shuttle missions with the goal of determining the processes at work and any potential mitigation strategies. This discussion will acquaint you with the changes that NASA has made to its medical requirements in order to address the microgravity induced intracranial hypertension and associated visual changes. Key personnel have been assembled to provide you information on this topic. Educational Objectives: Provide an overview of the current Medical Operations requirements and the mitigation steps taken to operationally address the issue.
Field: a new meta-authoring platform for data-intensive scientific visualization
NASA Astrophysics Data System (ADS)
Downie, M.; Ameres, E.; Fox, P. A.; Goebel, J.; Graves, A.; Hendler, J.
2012-12-01
This presentation will demonstrate a new platform for data-intensive scientific visualization, called Field, that rethinks the problem of visual data exploration. Several new opportunities for scientific visualization present themselves here at this moment in time. We believe that when taken together they may catalyze a transformation of the practice of science and to begin to seed a technical culture within science that fuses data analysis, programming and myriad visual strategies. It is at integrative levels that the principle challenges exist, for many fundamental technical components of our field are now well understood and widely available. File formats from CSV through HDF all have broad library support; low-level high-performance graphics APIs (OpenGL) are in a period of stable growth; and a dizzying ecosystem of analysis and machine learning libraries abound. The hardware of computer graphics offers unprecedented computing power within commodity components; programming languages and platforms are coalescing around a core set of umbrella runtimes. Each of these trends are each set to continue — computer graphics hardware is developing at a super-Moore-law rate, and trends in publication and dissemination point only towards an increasing amount of access to code and data. The critical opportunity here for scientific visualization is, we maintain, not a in developing a new statistical library, nor a new tool centered on a particular technique, but rather new visual, "live" programming environment that is promiscuous in its scope. We can identify the necessarily methodological practice and traditions required here not in science or engineering but in the "live-coding" practices prevalent in the fields of digital art and design. We can define this practice as an approach to programming that is live, iterative, integrative, speculative and exploratory. "Live" because it is exclusively practiced in real-time (often during performance); "iterative", because intermediate programs and this visual results are constantly being made and remade en route; "speculative", because these programs and images result out of mode of inquiry into image-making not unlike that of hypothesis formation and testing; "integrative" because this style draws deeply upon the libraries of algorithms and materials available online today; and "exploratory" because the results of these speculations are inherently open to the data and unforeseen out the outset. To this end our development environment — Field — comprises a minimal core and a powerful plug-in system that can be extended from within the environment itself. By providing a hybrid text editor that can incorporate text-based programming at the same time with graphical user-interface elements, its flexible and extensible interface provides space as necessary for notation, visualization, interface construction, and introspection. In addition, it provides an advanced GPU-accelerated graphics system ideal for large-scale data visualization. Since Field was created in the context of widely divergent interdisciplinary projects, its aim is to give its users not only the ability to work rapidly, but to shape their Field environment extensively and flexibly for their own demands.
Vision, Training Hours, and Road Testing Results in Bioptic Drivers
Dougherty, Bradley E.; Flom, Roanne E.; Bullimore, Mark A.; Raasch, Thomas W.
2015-01-01
Purpose Bioptic telescopic spectacles (BTS) can be used by people with central visual acuity that does not meet the state standards to obtain an unrestricted driver’s license. The purpose of this study was to examine the relationships among visual and demographic factors, training hours, and the results of road testing for bioptic drivers. Methods A retrospective study of patients who received an initial daylight bioptic examination at the Ohio State University and subsequently received a bioptic license was conducted. Data were collected on vision including visual acuity, contrast sensitivity, and visual field. Hours of driver training and results of Highway Patrol road testing were extracted from records. Relationships among vision, training hours, and road testing were analyzed. Results Ninety-seven patients who completed a vision examination between 2004 and 2008 and received daylight licensure with BTS were included. Results of the first Highway Patrol road test were available for 74 patients. The median interquartile range (IQR) hours of training prior to road testing was 21±17 hours, (range of 9 to 75 hours). Candidates without previous licensure were younger (p< 0.001) and had more documented training (p< 0.001). Lack of previous licensure and more training were significantly associated with having failed a portion of the Highway Patrol test and points deducted on the road test. Conclusions New bioptic drivers without previous non-bioptic driving experience required more training and performed more poorly on road testing for licensure than those who had previous non-bioptic licensure. No visual factor was predictive of road testing results after adjustment for previous experience. The hours of training received remained predictive of road testing outcome even with adjustment for previous experience. These results suggest that previous experience and trainer assessments should be investigated as potential predictors of road safety in bioptic drivers in future studies. PMID:25946098
Mohamed, Saleh M H; Börger, Norbert A; Geuze, Reint H; van der Meere, Jaap J
2016-10-01
Many clinical studies have shown that performance of subjects with attention-deficit/hyperactivity disorder (ADHD) is impaired when stimuli are presented at a slow rate compared to a medium or fast rate. According to the cognitive-energetic model, this finding may reflect difficulty in allocating sufficient effort to regulate the motor activation state. Other studies have shown that the left hemisphere is relatively responsible for keeping humans motivated, allocating sufficient effort to complete their tasks. This leads to a prediction that poor effort allocation might be associated with an affected left-hemisphere functioning in ADHD. So far, this prediction has not been directly tested, which is the aim of the present study. Seventy-seven adults with various scores on the Conners' Adult ADHD Rating Scale performed a lateralized lexical decision task in three conditions with stimuli presented in a fast, a medium, and a slow rate. The left-hemisphere functioning was measured in terms of visual field advantage (better performance for the right than for the left visual field). All subjects showed an increased right visual field advantage for word processing in the slow presentation rate of stimuli compared to the fast and the medium rate. Higher ADHD scores were related to a reduced right visual field advantage in the slow rate only. The present findings suggest that ADHD symptomatology is associated with less involvement of the left hemisphere when extra effort allocation is needed to optimize the low motor activation state.
NASA Technical Reports Server (NTRS)
Banks, Daniel W.
2008-01-01
Infrared thermography is a powerful tool for investigating fluid mechanics on flight vehicles. (Can be used to visualize and characterize transition, shock impingement, separation etc.). Updated onboard F-15 based system was used to visualize supersonic boundary layer transition test article. (Tollmien-Schlichting and cross-flow dominant flow fields). Digital Recording improves image quality and analysis capability. (Allows accurate quantitative (temperature) measurements, Greater enhancement through image processing allows analysis of smaller scale phenomena).
Propeller flow visualization techniques
NASA Technical Reports Server (NTRS)
Stefko, G. L.; Paulovich, F. J.; Greissing, J. P.; Walker, E. D.
1982-01-01
Propeller flow visualization techniques were tested. The actual operating blade shape as it determines the actual propeller performance and noise was established. The ability to photographically determine the advanced propeller blade tip deflections, local flow field conditions, and gain insight into aeroelastic instability is demonstrated. The analytical prediction methods which are being developed can be compared with experimental data. These comparisons contribute to the verification of these improved methods and give improved capability for designing future advanced propellers with enhanced performance and noise characteristics.
Romano, Mary; Iacovello, Daniela; Cascone, Nikhil C; Contestabile, Maria Teresa
2011-01-01
To document the clinical, functional, and in vivo microanatomic characteristics of a patient with Gorlin-Goltz syndrome with a novel nonsense mutation in PTCH (patched). Optical coherence tomography (OCT), fluorescein angiography, electrophysiologic testing, visual field, magnetic resonance imaging, and mutation screening of PTCH gene. Visual acuity was 20/20 in the right eye and 20/25 in the left. Fundus examination revealed myelinated nerve fibers in the left eye and bilateral epiretinal membranes with lamellar macular hole also documented with macular OCT. A reduction of the retinal nerve fiber layers in both eyes was found with fiber nervous OCT. Fluorescein angiography showed bilaterally foveal hyperfluorescence and the visual field revealed inferior hemianopia in the right eye. Pattern visual evoked potentials registered a reduction of amplitude in both eyes and latency was delayed in the left eye. Pattern electroretinogram showed a reduction in P50 and N95 peak time and a delay in P50 peak time in the left eye. Flash electroretinogram was reduced in rod response, maximal response, and oscillatory potentials in both eyes. Cone response was normal and 30-Hz flicker was slightly reduced in both eyes. Mutation screening identified a novel nonsense mutation in PTCH. A novel nonsense mutation in the PTCH gene was found. We report the occurrence of epiretinal membranes and the persistence of myelinated nerve fibers. Electrophysiologic and visual field alterations, supporting a neuroretinal dysfunction, were also documented.
Small numbers are sensed directly, high numbers constructed from size and density.
Zimmermann, Eckart
2018-04-01
Two theories compete to explain how we estimate the numerosity of visual object sets. The first suggests that the apparent numerosity is derived from an analysis of more low-level features like size and density of the set. The second theory suggests that numbers are sensed directly. Consistent with the latter claim is the existence of neurons in parietal cortex which are specialized for processing the numerosity of elements in the visual scene. However, recent evidence suggests that only low numbers can be sensed directly whereas the perception of high numbers is supported by the analysis of low-level features. Processing of low and high numbers, being located at different levels of the neural hierarchy should involve different receptive field sizes. Here, I tested this idea with visual adaptation. I measured the spatial spread of number adaptation for low and high numerosities. A focused adaptation spread of high numerosities suggested the involvement of early neural levels where receptive fields are comparably small and the broad spread for low numerosities was consistent with processing of number neurons which have larger receptive fields. These results provide evidence for the claim that different mechanism exist generating the perception of visual numerosity. Whereas low numbers are sensed directly as a primary visual attribute, the estimation of high numbers however likely depends on the area size over which the objects are spread. Copyright © 2017 Elsevier B.V. All rights reserved.
Mechanisms Underlying Development of Visual Maps and Receptive Fields
Huberman, Andrew D.; Feller, Marla B.; Chapman, Barbara
2008-01-01
Patterns of synaptic connections in the visual system are remarkably precise. These connections dictate the receptive field properties of individual visual neurons and ultimately determine the quality of visual perception. Spontaneous neural activity is necessary for the development of various receptive field properties and visual feature maps. In recent years, attention has shifted to understanding the mechanisms by which spontaneous activity in the developing retina, lateral geniculate nucleus, and visual cortex instruct the axonal and dendritic refinements that give rise to orderly connections in the visual system. Axon guidance cues and a growing list of other molecules, including immune system factors, have also recently been implicated in visual circuit wiring. A major goal now is to determine how these molecules cooperate with spontaneous and visually evoked activity to give rise to the circuits underlying precise receptive field tuning and orderly visual maps. PMID:18558864
Action video game players and deaf observers have larger Goldmann visual fields.
Buckley, David; Codina, Charlotte; Bhardwaj, Palvi; Pascalis, Olivier
2010-03-05
We used Goldmann kinetic perimetry to compare how training and congenital auditory deprivation may affect the size of the visual field. We measured the ability of action video game players and deaf observers to detect small moving lights at various locations in the central (around 30 degrees from fixation) and peripheral (around 60 degrees ) visual fields. Experiment 1 found that 10 habitual video game players showed significantly larger central and peripheral field areas than 10 controls. In Experiment 2 we found that 13 congenitally deaf observers had significantly larger visual fields than 13 hearing controls for both the peripheral and central fields. Here the greatest differences were found in the lower parts of the fields. Comparison of the two groups showed that whereas VGP players have a more uniform increase in field size in both central and peripheral fields deaf observers show non-uniform increases with greatest increases in lower parts of the visual field.
Avian binocular vision: It's not just about what birds can see, it's also about what they can't.
Tyrrell, Luke P; Fernández-Juricic, Esteban
2017-01-01
With the exception of primates, most vertebrates have laterally placed eyes. Binocular vision in vertebrates has been implicated in several functions, including depth perception, contrast discrimination, etc. However, the blind area in front of the head that is proximal to the binocular visual field is often neglected. This anterior blind area is important when discussing the evolution of binocular vision because its relative length is inversely correlated with the width of the binocular field. Therefore, species with wider binocular fields also have shorter anterior blind areas and objects along the mid-sagittal plane can be imaged at closer distances. Additionally, the anterior blind area is of functional significance for birds because the beak falls within this blind area. We tested for the first time some specific predictions about the functional role of the anterior blind area in birds controlling for phylogenetic effects. We used published data on visual field configuration in 40 species of birds and measured beak and skull parameters from museum specimens. We found that birds with proportionally longer beaks have longer anterior blind areas and thus narrower binocular fields. This result suggests that the anterior blind area and beak visibility do play a role in shaping binocular fields, and that binocular field width is not solely determined by the need for stereoscopic vision. In visually guided foragers, the ability to see the beak-and how much of the beak can be seen-varies predictably with foraging habits. For example, fish- and insect-eating specialists can see more of their own beak than birds eating immobile food can. But in non-visually guided foragers, there is no consistent relationship between the beak and anterior blind area. We discuss different strategies-wide binocular fields, large eye movements, and long beaks-that minimize the potential negative effects of the anterior blind area. Overall, we argue that there is more to avian binocularity than meets the eye.
Letelier, Juan-Carlos; Marin, Gonzalo; Sentis, Elisa; Tenreiro, Andrea; Fredes, Felipe; Mpodozis, Jorge
2004-01-30
Most of the physiological studies of the pigeon retino-tectal visual pathway have investigated the accessible tectum, a small dorso-lateral tectal section that can be easily accessed by a simple craniotomy. However, at present we lack a detailed study of the topographical arrangement between the visual field, the retina and the accessible tectum. In particular, it is not known which section of the visual field is mapped onto the accessible tectum, and which of the specialized retinal areas mediates this projection. Here we determined, using local field potential (LFP) recordings and reverse retinoscopy, the shape, size and position in the visual space of the portion of the visual field mapped onto the accessible tectum (called here the accessible visual field, or AVF). Using this data and the mapping of Nalbach et al. [Vis. Res. 30 (4) (1990) 529], the retinal area corresponding to the AVF was determined. Such retinal area was also directly delimited by means of retrograde transport of DiI. The results indicate that the AVF is a triangular perifoveal zone encompassing only 15% of total visual field. The retinal region corresponding to the AVF has the shape of an elongated triangle that runs parallel to the visual equator and contains the fovea, the tip of the pecten, a perifoveal region of the yellow field and a small crescent of the red field. In agreement with this anatomical heterogeneity, visual evoked potentials measured in different parts of the accessible tectum present steep variations in shape and size. These results are helpful to better design and interpret anatomical and physiological experiments involving the pigeon's visual system.
Horn, Folkert K; Selle, Franziska; Hohberger, Bettina; Kremers, Jan
2016-02-01
To investigate whether a conventional, monitor-based multifocal visual evoked potential (mfVEP) system can be used to record steady-state mfVEP (ssmfVEP) in healthy subjects and to study the effects of temporal frequency, electrode configuration and alpha waves. Multifocal pattern reversal VEP measurements were performed at 58 dartboard fields using VEP recording equipment. The responses were measured using m-sequences with four pattern reversals per m-step. Temporal frequencies were varied between 6 and 15 Hz. Recordings were obtained from nine normal subjects with a cross-shaped, four-electrode device (two additional channels were derived). Spectral analyses were performed on the responses at all locations. The signal to noise ratio (SNR) was computed for each response using the signal amplitude at the reversal frequency and the noise at the neighbouring frequencies. Most responses in the ssmfVEP were significantly above noise. The SNR was largest for an 8.6-Hz reversal frequency. The individual alpha electroencephalogram (EEG) did not strongly influence the results. The percentage of the records in which each of the 6 channels had the largest SNR was between 10.0 and 25.2 %. Our results in normal subjects indicate that reliable mfVEP responses can be achieved by steady-state stimulation using a conventional dartboard stimulator and multi-channel electrode device. The ssmfVEP may be useful for objective visual field assessment as spectrum analysis can be used for automated evaluation of responses. The optimal reversal frequency is 8.6 Hz. Alpha waves have only a minor influence on the analysis. Future studies must include comparisons with conventional mfVEP and psychophysical visual field tests.
The efficacy of a novel mobile phone application for goldmann ptosis visual field interpretation.
Maamari, Robi N; D'Ambrosio, Michael V; Joseph, Jeffrey M; Tao, Jeremiah P
2014-01-01
To evaluate the efficacy of a novel mobile phone application that calculates superior visual field defects on Goldmann visual field charts. Experimental study in which the mobile phone application and 14 oculoplastic surgeons interpreted the superior visual field defect in 10 Goldmann charts. Percent error of the mobile phone application and the oculoplastic surgeons' estimates were calculated compared with computer software computation of the actual defects. Precision and time efficiency of the application were evaluated by processing the same Goldmann visual field chart 10 repeated times. The mobile phone application was associated with a mean percent error of 1.98% (95% confidence interval[CI], 0.87%-3.10%) in superior visual field defect calculation. The average mean percent error of the oculoplastic surgeons' visual estimates was 19.75% (95% CI, 14.39%-25.11%). Oculoplastic surgeons, on average, underestimated the defect in all 10 Goldmann charts. There was high interobserver variance among oculoplastic surgeons. The percent error of the 10 repeated measurements on a single chart was 0.93% (95% CI, 0.40%-1.46%). The average time to process 1 chart was 12.9 seconds (95% CI, 10.9-15.0 seconds). The mobile phone application was highly accurate, precise, and time-efficient in calculating the percent superior visual field defect using Goldmann charts. Oculoplastic surgeon visual interpretations were highly inaccurate, highly variable, and usually underestimated the field vision loss.
Optical cylinder designs to increase the field of vision in the osteo-odonto-keratoprosthesis.
Hull, C C; Liu, C S; Sciscio, A; Eleftheriadis, H; Herold, J
2000-12-01
The single optical cylinders used in the osteo-odonto-keratoprosthesis (OOKP) are known to produce very small visual fields. Values of 40 degrees are typically quoted. The purpose of this paper is to present designs for new optical cylinders that significantly increase the field of view and therefore improve the visual rehabilitation of patients having an OOKP. Computer ray-tracing techniques were used to design and analyse improved one- and two-piece optical cylinders made from polymethyl methacrylate. All designs were required to have a potential visual acuity of 6/6 before consideration was given to the visual field and optimising off-axis image quality. Aspheric surfaces were used where this significantly improved off-axis image quality. Single optical cylinders, with increased posterior cylinder (intraocular) diameters, gave an increase in the theoretical visual field of 18% (from 76 degrees to 90 degrees) over current designs. Two-piece designs based on an inverted telephoto principle gave theoretical field angles over 120 degrees. Aspheric surfaces were shown to improve the off-axis image quality while maintaining a potential visual acuity of at least 6/6. This may well increase the measured visual field by improving the retinal illuminance off-axis. Results demonstrate that it is possible to significantly increase the theoretical maximum visual field through OOKP optical cylinders. Such designs will improve the visual rehabilitation of patients undergoing this procedure.
Learning to Recognize Patterns: Changes in the Visual Field with Familiarity
NASA Astrophysics Data System (ADS)
Bebko, James M.; Uchikawa, Keiji; Saida, Shinya; Ikeda, Mitsuo
1995-01-01
Two studies were conducted to investigate changes which take place in the visual information processing of novel stimuli as they become familiar. Japanese writing characters (Hiragana and Kanji) which were unfamiliar to two native English speaking subjects were presented using a moving window technique to restrict their visual fields. Study time for visual recognition was recorded across repeated sessions, and with varying visual field restrictions. The critical visual field was defined as the size of the visual field beyond which further increases did not improve the speed of recognition performance. In the first study, when the Hiragana patterns were novel, subjects needed to see about half of the entire pattern simultaneously to maintain optimal performance. However, the critical visual field size decreased as familiarity with the patterns increased. These results were replicated in the second study with more complex Kanji characters. In addition, the critical field size decreased as pattern complexity decreased. We propose a three component model of pattern perception. In the first stage a representation of the stimulus must be constructed by the subject, and restricting of the visual field interferes dramatically with this component when stimuli are unfamiliar. With increased familiarity, subjects become able to reconstruct a previous representation from very small, unique segments of the pattern, analogous to the informativeness areas hypothesized by Loftus and Mackworth [J. Exp. Psychol., 4 (1978) 565].
Influence of background size, luminance and eccentricity on different adaptation mechanisms
Gloriani, Alejandro H.; Matesanz, Beatriz M.; Barrionuevo, Pablo A.; Arranz, Isabel; Issolio, Luis; Mar, Santiago; Aparicio, Juan A.
2016-01-01
Mechanisms of light adaptation have been traditionally explained with reference to psychophysical experimentation. However, the neural substrata involved in those mechanisms remain to be elucidated. Our study analyzed links between psychophysical measurements and retinal physiological evidence with consideration for the phenomena of rod-cone interactions, photon noise, and spatial summation. Threshold test luminances were obtained with steady background fields at mesopic and photopic light levels (i.e., 0.06–110 cd/m2) for retinal eccentricities from 0° to 15° using three combinations of background/test field sizes (i.e., 10°/2°, 10°/0.45°, and 1°/0.45°). A two-channel Maxwellian view optical system was employed to eliminate pupil effects on the measured thresholds. A model based on visual mechanisms that were described in the literature was optimized to fit the measured luminance thresholds in all experimental conditions. Our results can be described by a combination of visual mechanisms. We determined how spatial summation changed with eccentricity and how subtractive adaptation changed with eccentricity and background field size. According to our model, photon noise plays a significant role to explain contrast detection thresholds measured with the 1/0.45° background/test size combination at mesopic luminances and at off-axis eccentricities. In these conditions, our data reflect the presence of rod-cone interaction for eccentricities between 6° and 9° and luminances between 0.6 and 5 cd/m2. In spite of the increasing noise effects with eccentricity, results also show that the visual system tends to maintain a constant signal-to-noise ratio in the off-axis detection task over the whole mesopic range. PMID:27210038
Influence of background size, luminance and eccentricity on different adaptation mechanisms.
Gloriani, Alejandro H; Matesanz, Beatriz M; Barrionuevo, Pablo A; Arranz, Isabel; Issolio, Luis; Mar, Santiago; Aparicio, Juan A
2016-08-01
Mechanisms of light adaptation have been traditionally explained with reference to psychophysical experimentation. However, the neural substrata involved in those mechanisms remain to be elucidated. Our study analyzed links between psychophysical measurements and retinal physiological evidence with consideration for the phenomena of rod-cone interactions, photon noise, and spatial summation. Threshold test luminances were obtained with steady background fields at mesopic and photopic light levels (i.e., 0.06-110cd/m(2)) for retinal eccentricities from 0° to 15° using three combinations of background/test field sizes (i.e., 10°/2°, 10°/0.45°, and 1°/0.45°). A two-channel Maxwellian view optical system was employed to eliminate pupil effects on the measured thresholds. A model based on visual mechanisms that were described in the literature was optimized to fit the measured luminance thresholds in all experimental conditions. Our results can be described by a combination of visual mechanisms. We determined how spatial summation changed with eccentricity and how subtractive adaptation changed with eccentricity and background field size. According to our model, photon noise plays a significant role to explain contrast detection thresholds measured with the 1/0.45° background/test size combination at mesopic luminances and at off-axis eccentricities. In these conditions, our data reflect the presence of rod-cone interaction for eccentricities between 6° and 9° and luminances between 0.6 and 5cd/m(2). In spite of the increasing noise effects with eccentricity, results also show that the visual system tends to maintain a constant signal-to-noise ratio in the off-axis detection task over the whole mesopic range. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gauvin, Mathieu; Chakor, Hadi; Koenekoop, Robert K; Little, John M; Lina, Jean-Marc; Lachapelle, Pierre
2016-06-01
A patient initially presented with constricted visual field, attenuated retinal vasculature, pigmentary clumping and reduced ERG in OS only, suggestive of unilateral retinitis pigmentosa (RP). This patient was subsequently seen on eight occasions (over three decades), and, with time, the initially normal eye (OD) gradually showed signs of RP-like degeneration. The purpose of this study was to evaluate which clinical modality (visual field, funduscopy or electroretinography) could have first predicted this fate. At each time points, data obtained from our patient were compared to normative data using Z tests. At initial visit, all tests were significantly (p < 0.05) altered in OS and normal in OD. Visual field and retinal vessel diameter in OD reduced gradually to reach statistical significance at the 5th visit and 6th visit (21 and 22 years after the first examination, respectively). In OD, the amplitude of the scotopic and photopic ERGs reduced gradually and was significantly smaller than normal at the 2nd visit (after 11 years) and 3rd visit (after 18 years), respectively. When the photopic ERG was analyzed using the discrete wavelet transform (DWT), we were able to detect a significant change at the 2nd visit (after 11 years) instead of the 3rd visit (18 years). Our study allowed us to witness the earliest manifestation of an RP disease process. The ERG was the first test to detect significant RP changes. A significantly earlier detection of ERG anomalies was obtained when the DWT was used, demonstrating its advantage for early detection of ERG changes.
Raudies, Florian; Hasselmo, Michael E.
2015-01-01
Firing fields of grid cells in medial entorhinal cortex show compression or expansion after manipulations of the location of environmental barriers. This compression or expansion could be selective for individual grid cell modules with particular properties of spatial scaling. We present a model for differences in the response of modules to barrier location that arise from different mechanisms for the influence of visual features on the computation of location that drives grid cell firing patterns. These differences could arise from differences in the position of visual features within the visual field. When location was computed from the movement of visual features on the ground plane (optic flow) in the ventral visual field, this resulted in grid cell spatial firing that was not sensitive to barrier location in modules modeled with small spacing between grid cell firing fields. In contrast, when location was computed from static visual features on walls of barriers, i.e. in the more dorsal visual field, this resulted in grid cell spatial firing that compressed or expanded based on the barrier locations in modules modeled with large spacing between grid cell firing fields. This indicates that different grid cell modules might have differential properties for computing location based on visual cues, or the spatial radius of sensitivity to visual cues might differ between modules. PMID:26584432
Useful visual field in patients with schizophrenia: a choice reaction time study.
Matsuda, Yukihisa; Matsui, Mie; Tonoya, Yasuhiro; Ebihara, Naokuni; Kurachi, Masayoshi
2011-04-01
This study examined the size of the useful visual field in patients (9 men, 6 women) with schizophrenia. A choice reaction task was conducted, and performances at 2.5, 5, 7, 10, and 25 degrees in both visual fields were measured. Three key findings were shown. First, patients had slower choice reaction times (choice RTs) than normal controls. Second, patients had slower choice RTs in the right visual field than in the left visual field. Third, patients and normal controls showed the same U-shaped choice RT pattern. The first and second findings were consistent with those of other studies. The third finding was a clear indication of the patients' performance in peripheral vision, and a comparison with normal controls suggested that there was no difference in the size of the useful visual field, at least within
Anti-inflammatory effect of hamamelis lotion in a UVB erythema test.
Hughes-Formella, B J; Bohnsack, K; Rippke, F; Benner, G; Rudolph, M; Tausch, I; Gassmueller, J
1998-01-01
Although Hamamelis virginiana has long been used in the traditional treatment of skin diseases, there are few controlled clinical studies defining the extent of its anti-inflammatory action. The anti-inflammatory efficacy of pH5 Eucerin aftersun lotion with 10% hamamelis distillate, the vehicle and a prior aftersun formulation were tested in 30 healthy volunteers using a modified UVB erythema test as model of inflammation. Four UVB doses ranging from 1 to 2 MED were evaluated in each subject. Test fields on the back were treated occlusively for 48 h following irradiation. Chromametry and visual scoring were used to determine the degree of erythema in the treated fields and an untreated, irradiated control field 7, 24 and 48 h after irradiation. Erythema suppression ranged from approximately 20% of 7 h to 27% at 48 h in the hamamelis fields. A suppression of 11-15% was recorded in the fields treated with the other lotions. Significant differences were noted between hamamelis and these lotions. These data provide evidence for an anti-inflammatory action of the aftersun lotion with 10% hamamelis and support the usefulness of the UVB erythema test with multiple UV doses for the testing of nonsteroidal anti-inflammatory agents.
The "Rod and Fran Test": relationship priming influences cognitive-perceptual performance.
Baldwin, Mark W; Bagust, Jeff; Docherty, Sharon; Browman, Alexander S; Jackson, Joshua C
2014-01-01
We theorized that interpersonal relationships can provide structures for experience. In particular, we tested whether primes of same-sex versus mixed-sex relationships could foster cognitive-perceptual processing styles known to be associated with independence versus interdependence respectively. Seventy-two participants visualized either a same-sex or other-sex relationship partner and then performed two measures of cognitive-perceptual style. On a computerized Rod and Frame Test, individuals were more field-dependent after visualizing a mixed-sex versus same-sex relationship partner. On a measure involving perceptions of group behavior, participants demonstrated more holistic/contextually based perception after being primed with a female versus male relationship partner. These findings support the hypothesis that activated cognitive structures representing interpersonal relationships can shape individuals' cognitive-perceptual performance.
Pigmentary glaucoma accompanied by Usher syndrome.
Koucheki, Behrooz; Jalali, Kamran Hodjat
2012-08-01
To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.
Emotion computing using Word Mover's Distance features based on Ren_CECps.
Ren, Fuji; Liu, Ning
2018-01-01
In this paper, we propose an emotion separated method(SeTF·IDF) to assign the emotion labels of sentences with different values, which has a better visual effect compared with the values represented by TF·IDF in the visualization of a multi-label Chinese emotional corpus Ren_CECps. Inspired by the enormous improvement of the visualization map propelled by the changed distances among the sentences, we being the first group utilizes the Word Mover's Distance(WMD) algorithm as a way of feature representation in Chinese text emotion classification. Our experiments show that both in 80% for training, 20% for testing and 50% for training, 50% for testing experiments of Ren_CECps, WMD features get the best f1 scores and have a greater increase compared with the same dimension feature vectors obtained by dimension reduction TF·IDF method. Compared experiments in English corpus also show the efficiency of WMD features in the cross-language field.
Vos, Leia; Whitman, Douglas
2014-01-01
A considerable literature suggests that the right hemisphere is dominant in vigilance for novel and survival-related stimuli, such as predators, across a wide range of species. In contrast to vigilance for change, change blindness is a failure to detect obvious changes in a visual scene when they are obscured by a disruption in scene presentation. We studied lateralised change detection using a series of scenes with salient changes in either the left or right visual fields. In Study 1 left visual field changes were detected more rapidly than right visual field changes, confirming a right hemisphere advantage for change detection. Increasing stimulus difficulty resulted in greater right visual field detections and left hemisphere detection was more likely when change occurred in the right visual field on a prior trial. In Study 2 an intervening distractor task disrupted the influence of prior trials. Again, faster detection speeds were observed for the left visual field changes with a shift to a right visual field advantage with increasing time-to-detection. This suggests that a right hemisphere role for vigilance, or catching attention, and a left hemisphere role for target evaluation, or maintaining attention, is present at the earliest stage of change detection.
Rooney, Kevin K.; Condia, Robert J.; Loschky, Lester C.
2017-01-01
Neuroscience has well established that human vision divides into the central and peripheral fields of view. Central vision extends from the point of gaze (where we are looking) out to about 5° of visual angle (the width of one’s fist at arm’s length), while peripheral vision is the vast remainder of the visual field. These visual fields project to the parvo and magno ganglion cells, which process distinctly different types of information from the world around us and project that information to the ventral and dorsal visual streams, respectively. Building on the dorsal/ventral stream dichotomy, we can further distinguish between focal processing of central vision, and ambient processing of peripheral vision. Thus, our visual processing of and attention to objects and scenes depends on how and where these stimuli fall on the retina. The built environment is no exception to these dependencies, specifically in terms of how focal object perception and ambient spatial perception create different types of experiences we have with built environments. We argue that these foundational mechanisms of the eye and the visual stream are limiting parameters of architectural experience. We hypothesize that people experience architecture in two basic ways based on these visual limitations; by intellectually assessing architecture consciously through focal object processing and assessing architecture in terms of atmosphere through pre-conscious ambient spatial processing. Furthermore, these separate ways of processing architectural stimuli operate in parallel throughout the visual perceptual system. Thus, a more comprehensive understanding of architecture must take into account that built environments are stimuli that are treated differently by focal and ambient vision, which enable intellectual analysis of architectural experience versus the experience of architectural atmosphere, respectively. We offer this theoretical model to help advance a more precise understanding of the experience of architecture, which can be tested through future experimentation. (298 words) PMID:28360867
Rooney, Kevin K; Condia, Robert J; Loschky, Lester C
2017-01-01
Neuroscience has well established that human vision divides into the central and peripheral fields of view. Central vision extends from the point of gaze (where we are looking) out to about 5° of visual angle (the width of one's fist at arm's length), while peripheral vision is the vast remainder of the visual field. These visual fields project to the parvo and magno ganglion cells, which process distinctly different types of information from the world around us and project that information to the ventral and dorsal visual streams, respectively. Building on the dorsal/ventral stream dichotomy, we can further distinguish between focal processing of central vision, and ambient processing of peripheral vision. Thus, our visual processing of and attention to objects and scenes depends on how and where these stimuli fall on the retina. The built environment is no exception to these dependencies, specifically in terms of how focal object perception and ambient spatial perception create different types of experiences we have with built environments. We argue that these foundational mechanisms of the eye and the visual stream are limiting parameters of architectural experience. We hypothesize that people experience architecture in two basic ways based on these visual limitations; by intellectually assessing architecture consciously through focal object processing and assessing architecture in terms of atmosphere through pre-conscious ambient spatial processing. Furthermore, these separate ways of processing architectural stimuli operate in parallel throughout the visual perceptual system. Thus, a more comprehensive understanding of architecture must take into account that built environments are stimuli that are treated differently by focal and ambient vision, which enable intellectual analysis of architectural experience versus the experience of architectural atmosphere, respectively. We offer this theoretical model to help advance a more precise understanding of the experience of architecture, which can be tested through future experimentation. (298 words).
Artes, Paul H; Chauhan, Balwantray C; Keltner, John L; Cello, Kim E; Johnson, Chris A; Anderson, Douglas R; Gordon, Mae O; Kass, Michael A
2010-12-01
To assess agreement between longitudinal and cross-sectional analyses for determining visual field progression in data from the Ocular Hypertension Treatment Study. Visual field data from 3088 eyes of 1570 participants (median follow-up, 7 years) were analyzed. Longitudinal analyses were performed using change probability with total and pattern deviation, and cross-sectional analyses were performed using the glaucoma hemifield test, corrected pattern standard deviation, and mean deviation. The rates of mean deviation and general height change were compared to estimate the degree of diffuse loss in emerging glaucoma. Agreement on progression in longitudinal and cross-sectional analyses ranged from 50% to 61% and remained nearly constant across a wide range of criteria. In contrast, agreement on absence of progression ranged from 97.0% to 99.7%, being highest for the stricter criteria. Analyses of pattern deviation were more conservative than analyses of total deviation, with a 3 to 5 times lesser incidence of progression. Most participants developing field loss had both diffuse and focal changes. Despite considerable overall agreement, 40% to 50% of eyes identified as having progressed with either longitudinal or cross-sectional analyses were identified with only one of the analyses. Because diffuse change is part of early glaucomatous damage, pattern deviation analyses may underestimate progression in patients with ocular hypertension.
38 CFR 4.76a - Computation of average concentric contraction of visual fields.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentric contraction of visual fields. 4.76a Section 4.76a Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Organs of Special Sense § 4.76a Computation of average concentric contraction of visual fields. Table III—Normal Visual...
The functional significance of EEG microstates--Associations with modalities of thinking.
Milz, P; Faber, P L; Lehmann, D; Koenig, T; Kochi, K; Pascual-Marqui, R D
2016-01-15
The momentary, global functional state of the brain is reflected by its electric field configuration. Cluster analytical approaches consistently extracted four head-surface brain electric field configurations that optimally explain the variance of their changes across time in spontaneous EEG recordings. These four configurations are referred to as EEG microstate classes A, B, C, and D and have been associated with verbal/phonological, visual, subjective interoceptive-autonomic processing, and attention reorientation, respectively. The present study tested these associations via an intra-individual and inter-individual analysis approach. The intra-individual approach tested the effect of task-induced increased modality-specific processing on EEG microstate parameters. The inter-individual approach tested the effect of personal modality-specific parameters on EEG microstate parameters. We obtained multichannel EEG from 61 healthy, right-handed, male students during four eyes-closed conditions: object-visualization, spatial-visualization, verbalization (6 runs each), and resting (7 runs). After each run, we assessed participants' degrees of object-visual, spatial-visual, and verbal thinking using subjective reports. Before and after the recording, we assessed modality-specific cognitive abilities and styles using nine cognitive tests and two questionnaires. The EEG of all participants, conditions, and runs was clustered into four classes of EEG microstates (A, B, C, and D). RMANOVAs, ANOVAs and post-hoc paired t-tests compared microstate parameters between conditions. TANOVAs compared microstate class topographies between conditions. Differences were localized using eLORETA. Pearson correlations assessed interrelationships between personal modality-specific parameters and EEG microstate parameters during no-task resting. As hypothesized, verbal as opposed to visual conditions consistently affected the duration, occurrence, and coverage of microstate classes A and B. Contrary to associations suggested by previous reports, parameters were increased for class A during visualization, and class B during verbalization. In line with previous reports, microstate D parameters were increased during no-task resting compared to the three internal, goal-directed tasks. Topographic differences between conditions included particular sub-regions of components of the metabolic default mode network. Modality-specific personal parameters did not consistently correlate with microstate parameters except verbal cognitive style which correlated negatively with microstate class A duration and positively with class C occurrence. This is the first study that aimed to induce EEG microstate class parameter changes based on their hypothesized functional significance. Beyond the associations of microstate classes A and B with visual and verbal processing, respectively, our results suggest that a finely-tuned interplay between all four EEG microstate classes is necessary for the continuous formation of visual and verbal thoughts. Our results point to the possibility that the EEG microstate classes may represent the head-surface measured activity of intra-cortical sources primarily exhibiting inhibitory functions. However, additional studies are needed to verify and elaborate on this hypothesis. Copyright © 2015 Elsevier Inc. All rights reserved.
Reed-Jones, James G; Reed-Jones, Rebecca J; Hollands, Mark A
2014-04-30
The useful field of view (UFOV) is the visual area from which information is obtained at a brief glance. While studies have examined the effects of increased cognitive load on the visual field, no one has specifically looked at the effects of postural control or locomotor activity on the UFOV. The current study aimed to examine the effects of postural demand and locomotor activity on UFOV performance in healthy young adults. Eleven participants were tested on three modified UFOV tasks (central processing, peripheral processing, and divided-attention) while seated, standing, and stepping in place. Across all postural conditions, participants showed no difference in their central or peripheral processing. However, in the divided-attention task (reporting the letter in central vision and target location in peripheral vision amongst distracter items) a main effect of posture condition on peripheral target accuracy was found for targets at 57° of eccentricity (p=.037). The mean accuracy reduced from 80.5% (standing) to 74% (seated) to 56.3% (stepping). These findings show that postural demands do affect UFOV divided-attention performance. In particular, the size of the useful field of view significantly decreases when stepping. This finding has important implications for how the results of a UFOV test are used to evaluate the general size of the UFOV during varying activities, as the traditional seated test procedure may overestimate the size of the UFOV during locomotor activities. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Street, Nichola; Forsythe, Alexandra M; Reilly, Ronan; Taylor, Richard; Helmy, Mai S
2016-01-01
Fractal patterns offer one way to represent the rough complexity of the natural world. Whilst they dominate many of our visual experiences in nature, little large-scale perceptual research has been done to explore how we respond aesthetically to these patterns. Previous research (Taylor et al., 2011) suggests that the fractal patterns with mid-range fractal dimensions (FDs) have universal aesthetic appeal. Perceptual and aesthetic responses to visual complexity have been more varied with findings suggesting both linear (Forsythe et al., 2011) and curvilinear (Berlyne, 1970) relationships. Individual differences have been found to account for many of the differences we see in aesthetic responses but some, such as culture, have received little attention within the fractal and complexity research fields. This two-study article aims to test preference responses to FD and visual complexity, using a large cohort (N = 443) of participants from around the world to allow universality claims to be tested. It explores the extent to which age, culture and gender can predict our preferences for fractally complex patterns. Following exploratory analysis that found strong correlations between FD and visual complexity, a series of linear mixed-effect models were implemented to explore if each of the individual variables could predict preference. The first tested a linear complexity model (likelihood of selecting the more complex image from the pair of images) and the second a mid-range FD model (likelihood of selecting an image within mid-range). Results show that individual differences can reliably predict preferences for complexity across culture, gender and age. However, in fitting with current findings the mid-range models show greater consistency in preference not mediated by gender, age or culture. This article supports the established theory that the mid-range fractal patterns appear to be a universal construct underlying preference but also highlights the fragility of universal claims by demonstrating individual differences in preference for the interrelated concept of visual complexity. This highlights a current stalemate in the field of empirical aesthetics.
Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.
2009-01-01
Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306
Simulated visual field loss does not alter turning coordination in healthy young adults.
Murray, Nicholas G; Ponce de Leon, Marlina; Ambati, V N Pradeep; Saucedo, Fabricio; Kennedy, Evan; Reed-Jones, Rebecca J
2014-01-01
Turning, while walking, is an important component of adaptive locomotion. Current hypotheses regarding the motor control of body segment coordination during turning suggest heavy influence of visual information. The authors aimed to examine whether visual field impairment (central loss or peripheral loss) affects body segment coordination during walking turns in healthy young adults. No significant differences in the onset time of segments or intersegment coordination were observed because of visual field occlusion. These results suggest that healthy young adults can use visual information obtained from central and peripheral visual fields interchangeably, pointing to flexibility of visuomotor control in healthy young adults. Further study in populations with chronic visual impairment and those with turning difficulties are warranted.
Rowe, Fiona J.; Noonan, Carmel; Manuel, Melanie
2013-01-01
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Results. 64 patients (113 eyes) underwent dual perimetry assessment. Mean duration of assessment for SKP was 4.54 minutes ±0.18 and 6.17 ± 0.12 for FF120 (P = 0.0001). 80% of results were correctly matched for normal or abnormal visual fields using the I4e target versus FF120, and 73.5% were correctly matched using the I2e target versus FF120. When comparing Octopus results with combined I4e and I2e isopters to the FF120 result, a match for normal or abnormal fields was recorded in 87%. Conclusions. Humphrey perimetry test duration was generally longer than Octopus SKP. In the absence of kinetic perimetry, peripheral static suprathreshold programme options such as FF120 may be useful for detection of visual field defects. However, statokinetic dissociation may occur. Octopus SKP utilising both I4e and I2e targets provides detailed information of both the defect depth and size and may provide a more representative view of the actual visual field defect. PMID:24558605
Application of holography to flow visualization
NASA Technical Reports Server (NTRS)
Lee, G.
1984-01-01
Laser holographic interferometry is being applied to many different types of aerodynamics problems. These include two and three dimensional flows in wind tunnels, ballistic ranges, rotor test chambers and turbine facilities. Density over a large field is measured and velocity, pressure, and mach number can be deduced.
Digital implementation of a neural network for imaging
NASA Astrophysics Data System (ADS)
Wood, Richard; McGlashan, Alex; Yatulis, Jay; Mascher, Peter; Bruce, Ian
2012-10-01
This paper outlines the design and testing of a digital imaging system that utilizes an artificial neural network with unsupervised and supervised learning to convert streaming input (real time) image space into parameter space. The primary objective of this work is to investigate the effectiveness of using a neural network to significantly reduce the information density of streaming images so that objects can be readily identified by a limited set of primary parameters and act as an enhanced human machine interface (HMI). Many applications are envisioned including use in biomedical imaging, anomaly detection and as an assistive device for the visually impaired. A digital circuit was designed and tested using a Field Programmable Gate Array (FPGA) and an off the shelf digital camera. Our results indicate that the networks can be readily trained when subject to limited sets of objects such as the alphabet. We can also separate limited object sets with rotational and positional invariance. The results also show that limited visual fields form with only local connectivity.
Learning of goal-relevant and -irrelevant complex visual sequences in human V1.
Rosenthal, Clive R; Mallik, Indira; Caballero-Gaudes, Cesar; Sereno, Martin I; Soto, David
2018-06-12
Learning and memory are supported by a network involving the medial temporal lobe and linked neocortical regions. Emerging evidence indicates that primary visual cortex (i.e., V1) may contribute to recognition memory, but this has been tested only with a single visuospatial sequence as the target memorandum. The present study used functional magnetic resonance imaging to investigate whether human V1 can support the learning of multiple, concurrent complex visual sequences involving discontinous (second-order) associations. Two peripheral, goal-irrelevant but structured sequences of orientated gratings appeared simultaneously in fixed locations of the right and left visual fields alongside a central, goal-relevant sequence that was in the focus of spatial attention. Pseudorandom sequences were introduced at multiple intervals during the presentation of the three structured visual sequences to provide an online measure of sequence-specific knowledge at each retinotopic location. We found that a network involving the precuneus and V1 was involved in learning the structured sequence presented at central fixation, whereas right V1 was modulated by repeated exposure to the concurrent structured sequence presented in the left visual field. The same result was not found in left V1. These results indicate for the first time that human V1 can support the learning of multiple concurrent sequences involving complex discontinuous inter-item associations, even peripheral sequences that are goal-irrelevant. Copyright © 2018. Published by Elsevier Inc.
Noninvasive studies of human visual cortex using neuromagnetic techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aine, C.J.; George, J.S.; Supek, S.
1990-01-01
The major goals of noninvasive studies of the human visual cortex are: to increase knowledge of the functional organization of cortical visual pathways; and to develop noninvasive clinical tests for the assessment of cortical function. Noninvasive techniques suitable for studies of the structure and function of human visual cortex include magnetic resonance imaging (MRI), positron emission tomography (PET), single photon emission tomography (SPECT), scalp recorded event-related potentials (ERPs), and event-related magnetic fields (ERFs). The primary challenge faced by noninvasive functional measures is to optimize the spatial and temporal resolution of the measurement and analytic techniques in order to effectively characterizemore » the spatial and temporal variations in patterns of neuronal activity. In this paper we review the use of neuromagnetic techniques for this purpose. 8 refs., 3 figs.« less
Field evaluation of a prototype paper-based point-of-care fingerstick transaminase test.
Pollock, Nira R; McGray, Sarah; Colby, Donn J; Noubary, Farzad; Nguyen, Huyen; Nguyen, The Anh; Khormaee, Sariah; Jain, Sidhartha; Hawkins, Kenneth; Kumar, Shailendra; Rolland, Jason P; Beattie, Patrick D; Chau, Nguyen V; Quang, Vo M; Barfield, Cori; Tietje, Kathy; Steele, Matt; Weigl, Bernhard H
2013-01-01
Monitoring for drug-induced liver injury (DILI) via serial transaminase measurements in patients on potentially hepatotoxic medications (e.g., for HIV and tuberculosis) is routine in resource-rich nations, but often unavailable in resource-limited settings. Towards enabling universal access to affordable point-of-care (POC) screening for DILI, we have performed the first field evaluation of a paper-based, microfluidic fingerstick test for rapid, semi-quantitative, visual measurement of blood alanine aminotransferase (ALT). Our objectives were to assess operational feasibility, inter-operator variability, lot variability, device failure rate, and accuracy, to inform device modification for further field testing. The paper-based ALT test was performed at POC on fingerstick samples from 600 outpatients receiving HIV treatment in Vietnam. Results, read independently by two clinic nurses, were compared with gold-standard automated (Roche Cobas) results from venipuncture samples obtained in parallel. Two device lots were used sequentially. We demonstrated high inter-operator agreement, with 96.3% (95% C.I., 94.3-97.7%) agreement in placing visual results into clinically-defined "bins" (<3x, 3-5x, and >5x upper limit of normal), >90% agreement in validity determination, and intraclass correlation coefficient of 0.89 (95% C.I., 0.87-0.91). Lot variability was observed in % invalids due to hemolysis (21.1% for Lot 1, 1.6% for Lot 2) and correlated with lots of incorporated plasma separation membranes. Invalid rates <1% were observed for all other device controls. Overall bin placement accuracy for the two readers was 84% (84.3%/83.6%). Our findings of extremely high inter-operator agreement for visual reading-obtained in a target clinical environment, as performed by local practitioners-indicate that the device operation and reading process is feasible and reproducible. Bin placement accuracy and lot-to-lot variability data identified specific targets for device optimization and material quality control. This is the first field study performed with a patterned paper-based microfluidic device and opens the door to development of similar assays for other important analytes.
Organization of area hV5/MT+ in subjects with homonymous visual field defects.
Papanikolaou, Amalia; Keliris, Georgios A; Papageorgiou, T Dorina; Schiefer, Ulrich; Logothetis, Nikos K; Smirnakis, Stelios M
2018-04-06
Damage to the primary visual cortex (V1) leads to a visual field loss (scotoma) in the retinotopically corresponding part of the visual field. Nonetheless, a small amount of residual visual sensitivity persists within the blind field. This residual capacity has been linked to activity observed in the middle temporal area complex (V5/MT+). However, it remains unknown whether the organization of hV5/MT+ changes following early visual cortical lesions. We studied the organization of area hV5/MT+ of five patients with dense homonymous defects in a quadrant of the visual field as a result of partial V1+ or optic radiation lesions. To do so, we developed a new method, which models the boundaries of population receptive fields directly from the BOLD signal of each voxel in the visual cortex. We found responses in hV5/MT+ arising inside the scotoma for all patients and identified two possible sources of activation: 1) responses might originate from partially lesioned parts of area V1 corresponding to the scotoma, and 2) responses can also originate independent of area V1 input suggesting the existence of functional V1-bypassing pathways. Apparently, visually driven activity observed in hV5/MT+ is not sufficient to mediate conscious vision. More surprisingly, visually driven activity in corresponding regions of V1 and early extrastriate areas including hV5/MT+ did not guarantee visual perception in the group of patients with post-geniculate lesions that we examined. This suggests that the fine coordination of visual activity patterns across visual areas may be an important determinant of whether visual perception persists following visual cortical lesions. Copyright © 2018 Elsevier Inc. All rights reserved.
Six-month Longitudinal Comparison of a Portable Tablet Perimeter With the Humphrey Field Analyzer.
Prea, Selwyn Marc; Kong, Yu Xiang George; Mehta, Aditi; He, Mingguang; Crowston, Jonathan G; Gupta, Vinay; Martin, Keith R; Vingrys, Algis J
2018-06-01
To establish the medium-term repeatability of the iPad perimetry app Melbourne Rapid Fields (MRF) compared to Humphrey Field Analyzer (HFA) 24-2 SITA-standard and SITA-fast programs. Multicenter longitudinal observational clinical study. Sixty patients (stable glaucoma/ocular hypertension/glaucoma suspects) were recruited into a 6-month longitudinal clinical study with visits planned at baseline and at 2, 4, and 6 months. At each visit patients undertook visual field assessment using the MRF perimetry application and either HFA SITA-fast (n = 21) or SITA-standard (n = 39). The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests. Secondary measures were the point-wise threshold and repeatability for each test, as well as test time. MRF was similar to SITA-fast in speed and significantly faster than SITA-standard (MRF 4.6 ± 0.1 minutes vs SITA-fast 4.3 ± 0.2 minutes vs SITA-standard 6.2 ± 0.1 minutes, P < .001). Intraclass correlation coefficients (ICC) between MRF and SITA-fast for MD at the 4 visits ranged from 0.71 to 0.88. ICC values between MRF and SITA-standard for MD ranged from 0.81 to 0.90. Repeatability of MRF MD outcomes was excellent, with ICC for baseline and the 6-month visit being 0.98 (95% confidence interval: 0.96-0.99). In comparison, ICC at 6-month retest for SITA-fast was 0.95 and SITA-standard 0.93. Fewer points changed with the MRF, although for those that did, the MRF gave greater point-wise variability than did the SITA tests. MRF correlated strongly with HFA across 4 visits over a 6-month period, and has good test-retest reliability. MRF is suitable for monitoring visual fields in settings where conventional perimetry is not readily accessible. Copyright © 2018 Elsevier Inc. All rights reserved.