Sample records for visual function tester-4

  1. Effect of Microgravity on Several Visual Functions During STS Shuttle Missions: Visual Function Tester-model 1 (VFT-1)

    NASA Technical Reports Server (NTRS)

    Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.

    1992-01-01

    Viewgraphs on the effect of microgravity on several visual functions during STS shuttle missions are presented. The purpose, methods, results, and discussion are discussed. The visual function tester model 1 is used.

  2. Effect of microgravity on visual contrast threshold during STS Shuttle missions: Visual Function Tester-Model 2 (VFT-2)

    NASA Technical Reports Server (NTRS)

    Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.

    1992-01-01

    Viewgraphs on effect of microgravity on visual contrast threshold during STS shuttle missions are presented. The purpose, methods, and results are discussed. The visual function tester model 2 is used.

  3. STS-44 Pilot Henricks uses Visual Function Tester (VFT) on OV-104's middeck

    NASA Image and Video Library

    1991-12-01

    STS044-14-013 (24 Nov-1 Dec 1991) --- Terence T. (Tom) Henricks, STS-44 pilot, tests his visual acuity with the Visual Function Test (VFT) apparatus. This photograph was among the first released by NASA following the eight day mission, dedicated to the Department of Defense.

  4. Comparison of the American Optical Vision Tester and the Armed Forces Far Visual Acuity Test. B-6-133-13

    DTIC Science & Technology

    1954-01-01

    THE AMERICAN OPTICAL VISION TESTER AND THE ARMED FORCES FAR VISUAL ACUITY TEST Comparisons were made of the visual acuity scores of 100 enlisted men on ...the American Optical Vision Tester (with Sloan plates) and on the Armed Forces Far Visual Acuity test. Order of presentation was: AO-left eye, AO...right eye, AFFVAT-left, AFVTAT-right. Correlation coefficients between AO and AFFVAT were around .89. Dispersion of acuity scores was about the same on

  5. Visual-Accommodation Trainer/Tester

    NASA Technical Reports Server (NTRS)

    Randle, Robert J., Jr.

    1986-01-01

    Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.

  6. Visual accommodation trainer-tester

    NASA Technical Reports Server (NTRS)

    Randle, R. J., Jr. (Inventor)

    1983-01-01

    An apparatus for training of the human visual accommodation system is presented, specifically, useful for training a person to volitionally control his focus to his far point (normaly infinity) from a position of myopia due to functional causes. The functional causes could be due, for example, to a behavioral accommodative spasm or the effects of an empty field. The device may also be used to measure accommodation, the accommodation resting position and the near and far points of vision.

  7. Reliability and validity of the Assessment of Daily Activity Performance (ADAP) in community-dwelling older women.

    PubMed

    de Vreede, Paul L; Samson, Monique M; van Meeteren, Nico L; Duursma, Sijmen A; Verhaar, Harald J

    2006-08-01

    The Assessment of Daily Activity Performance (ADAP) test was developed, and modeled after the Continuous-scale Physical Functional Performance (CS-PFP) test, to provide a quantitative assessment of older adults' physical functional performance. The aim of this study was to determine the intra-examiner reliability and construct validity of the ADAP in a community-living older population, and to identify the importance of tester experience. Forty-three community-dwelling, older women (mean age 75 yr +/-4.3) were randomized to the test-retest reliability study (n=19) or validation study (n=24). The intra-examiner reliability of an experienced (tester 1) and an inexperienced tester (tester 2) was assessed by comparing test and retest scores of 19 participants. Construct validity was assessed by comparing the ADAP scores of 24 participants with self-perceived function by the SF-36 Health Survey, muscle function tests, and the Timed Up and Go test (TUG). Tester 1 had good consistency and reliability scores (mean difference between test and retest scores (DIF), -1.05+/-1.99; 95% confidence interval (CI), -2.58 to 0.48; Cronbach's alpha (alpha) range, 0.83 to 0.98; intraclass correlation (ICC) range, 0.75 to 0.96; Limits of Agreement (LoA), -2.58 to 4.95). Tester 2 had lower reliability scores (DIF, -2.45+/-4.36; 95% CI, -5.56 to 0.67; alpha range, 0.53 to 0.94; ICC range, 0.36 to 0.90; LoA, -6.09 to 10.99), with a systematic difference between test and retest scores for the ADAP domain lower-body strength (-3.81; 95% CI, -6.09 to -1.54), ADAP correlated with SF-36 Physical Functioning scale (r=0.67), TUG test (r=-0.91) and with isometric knee extensor strength (r=0.80). The ADAP test is a reliable and valid instrument. Our results suggest that testers should practise using the test, to improve reliability, before applying it to clinical settings.

  8. Effect of microgravity on several visual functions during STS shuttle missions

    NASA Technical Reports Server (NTRS)

    Oneal, Melvin R.; Task, H. Lee; Genco, Louis V.

    1992-01-01

    Changes in the acuity of astronaut vision during flight are discussed. Parameters such as critical flicker vision, stereopsis to 10 seconds of arc, visual acuity in small steps to 20/7.7, cyclophoria, lateral and vertical phoria and retinal rivalry were tested using a visual function tester. Twenty-three Space Transportation System (STS) astronauts participated in the experiments. Their vision was assessed twice before launch and after landing, and three to four times while on-orbit and landing. No significant differences during space flight were observed for any of the visual parameters tested. In some cases, slight changes in acuity and stereopsis were observed with a subsequent return to normal vision after flight.

  9. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  10. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  11. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  12. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  13. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker electrode function tester. 870.3720... electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is... measuring the patient's pacing threshold and intracardiac R-wave potential. (b) Classification. Class II...

  14. Workplace field testing of the pressure drop of particulate respirators using welding fumes.

    PubMed

    Cho, Hyun-Woo; Yoon, Chung-Sik

    2012-10-01

    In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes were observed beneath the fourth layer of the tested respirators. The current findings contribute substantially to our understanding of respirator PD in the presence of welding fumes.

  15. Design review of fluid film bearing testers

    NASA Technical Reports Server (NTRS)

    Scharrer, Joseph K.

    1993-01-01

    The designs of three existing testers (Hybrid Bearing Tester, OTV Bearing Tester, and Long Life Bearing Tester) owned by NASA were reviewed for their capability to serve as a multi-purpose cryogenic fluid film bearing tester. The primary tester function is the validation of analytical predictions for fluid film bearing steady state and dynamic performance. Evaluation criteria were established for test bearing configurations, test fluids, instrumentation, and test objectives. Each tester was evaluated with respect to these criteria. A determination was made of design improvements which would allow the testers to meet the stated criteria. The cost and time required to make the design changes were estimated. A recommendation based on the results of this study was made to proceed with the Hybrid Bearing Tester.

  16. Tester-assisted built in test

    NASA Astrophysics Data System (ADS)

    Guntheroth, Kurt

    It is noted that board makers invest considerable time and money writing extensive self-tests and that this investment can be multiplied by selecting ATE (automatic test equipment) that complements and extends the power of the self-test. The tester can diagnose boards in situations where a fault prevents the self-test from running. If the tester monitors such resources as processor, memory, and I/O, confidence in test results is improved. The tester can be used during development of the self-test and to turn on prototypes before the self-test is complete. The author argues that emulative functional testers outperform other types of ATE on boards with BIST (built-in self-test) and lists features of emulative functional testers that are most important to users of BIST.

  17. Loopback Tester: a synchronous communications circuit diagnostic device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maestas, J.H.

    1986-07-01

    The Loopback Tester is an Intel SBC 86/12A Single Board Computer and an Intel SBC 534 Communications Expansion Board configured and programmed to perform various basic or less. These tests include: (1) Data Communications Equipment (DCE) transmit timing detection (2) data rate measurement (3) instantaneous loopback indication and (4) bit error rate testing. It requires no initial setup after plug in, and can be used to locate the source of communications loss in a circuit. It can also be used to determine when crypto variable mismatch problems are the source of communications loss. This report discusses the functionality of themore » Loopback Tester as a diagnostic device. It also discusses the hardware and software which implements this simple yet reliable device.« less

  18. 16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY... Standard Pt. 1209, Subpt. A, Fig. 4 Figure 4 to Subpart A of Part 1209—Flooring Radiant Panel Tester...

  19. Linkage to care following community-based mobile HIV testing compared with clinic-based testing in Umlazi Township, Durban, South Africa.

    PubMed

    Bassett, I V; Regan, S; Luthuli, P; Mbonambi, H; Bearnot, B; Pendleton, A; Robine, M; Mukuvisi, D; Thulare, H; Walensky, R P; Freedberg, K A; Losina, E; Mhlongo, B

    2014-07-01

    The aim of the study was to assess HIV prevalence, disease stage and linkage to HIV care following diagnosis at a mobile HIV testing unit, compared with results for clinic-based testing, in a Durban township. This was a prospective cohort study. We enrolled adults presenting for HIV testing at a community-based mobile testing unit (mobile testers) and at an HIV clinic (clinic testers) serving the same area. Testers diagnosed with HIV infection, regardless of testing site, were offered immediate CD4 testing and instructed to retrieve results at the clinic. We assessed rates of linkage to care, defined as CD4 result retrieval within 90 days of HIV diagnosis and/or completion of antiretroviral therapy (ART) literacy training, for mobile vs. clinic testers. From July to November 2011, 6957 subjects were HIV tested (4703 mobile and 2254 clinic); 55% were female. Mobile testers had a lower HIV prevalence than clinic testers (10% vs. 36%, respectively), were younger (median 23 vs. 27 years, respectively) and were more likely to live >5 km or >30 min from the clinic (64% vs. 40%, respectively; all P < 0.001). Mobile testers were less likely to undergo CD4 testing (33% vs. 83%, respectively) but more likely to have higher CD4 counts [median (interquartile range) 416 (287-587) cells/μL vs. 285 (136-482) cells/μL, respectively] than clinic testers (both P < 0.001). Of those who tested HIV positive, 10% of mobile testers linked to care, vs. 72% of clinic testers (P < 0.001). Mobile HIV testing reaches people who are younger, who are more geographically remote, and who have earlier disease compared with clinic-based testing. Fewer mobile testers underwent CD4 testing and linked to HIV care. Enhancing linkage efforts may improve the impact of mobile testing for those with early HIV disease. © 2013 British HIV Association.

  20. Adaptation of Psychological Assessment Tools for Administration by Blind and Visually Impaired Psychologists and Trainees.

    ERIC Educational Resources Information Center

    Keller, Richard M.

    This paper focuses on challenges to psychologists and psychology graduate students who are blind or visually impaired in the administration and scoring of various psychological tests. Organized by specific tests, the paper highlights those aspects of testing which pose particular difficulty to testers with visual impairments and also describes…

  1. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  2. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  3. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  4. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  5. 7 CFR 801.4 - Tolerances for dockage testers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...

  6. Development of a Low-Cost and High-speed Single Event Effects Testers based on Reconfigurable Field Programmable Gate Arrays (FPGA)

    NASA Technical Reports Server (NTRS)

    Howard, J. W.; Kim, H.; Berg, M.; LaBel, K. A.; Stansberry, S.; Friendlich, M.; Irwin, T.

    2006-01-01

    A viewgraph presentation on the development of a low cost, high speed tester reconfigurable Field Programmable Gata Array (FPGA) is shown. The topics include: 1) Introduction; 2) Objectives; 3) Tester Descriptions; 4) Tester Validations and Demonstrations; 5) Future Work; and 6) Summary.

  7. Factors to Consider When Implementing Automated Software Testing

    DTIC Science & Technology

    2016-11-10

    programming, e.g., Java or Visual Basic.  Subject Matter Experts (SME) with firm grasp of application being automated. 2. Additional costs for setup (e.g...Abilities (KSA) required (e.g., Test and Evaluation). 2. Analyze programming skills needed (e.g., Java , C, C++, Visual Basic). 3. Compose team – testers

  8. The reliability of the newly developed bending tester for the measurement of flexural rigidity of textile materials

    NASA Astrophysics Data System (ADS)

    Haji Musa, A. Binti; Malengier, B.; Van Langenhove, L.; Stevens, C.

    2017-10-01

    A new automated bending tester was developed in Ghent University, Belgium to reduce the human interference in the bending measurement. This paper reports the investigations made on the tester in order to confirm the reliability of its measurement. For that, 11 types of fabrics with different construction parameters were tested for their bending length and flexural rigidity using the new bending tester and the results were compared with that of the standard or manual bending tester, which were conducted in accordance with BS 3356:1990 standard method. Statistical analysis confirms that both measurements are strongly correlated with Pearson’s R≥ 0.90 for all the measurements made. It means that the results from the new automated tester show good correlations with the standard measurement. Nevertheless, this prototype version of the new tester still needs to be adjusted to optimise the functionality of it and further investigations should be done to justify the robustness of the results.

  9. Effect of a modified optic edge design on visual function: textured-edge versus round-anterior, slope-side edge.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2004-08-01

    To compare the impairment in visual function caused by glare with 2 acrylic intraocular lenses (IOLs) with different modified optic edges. Hayashi Eye Hospital, Fukuoka, Japan. Fifty-four patients had implantation of an IOL with a textured edge (Alcon MA60AC) in 1 eye and an IOL with a round-anterior, sloped-sided edge (AMO AR40e) in the opposite eye. Visual acuity was measured at 5 contrast visual targets (100%, 25%, 10%, 5%, and 2.5%) (contrast visual acuity) under photopic and mesopic conditions with and without a glare source approximately 1 month after surgery using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000). The mean mesopic contrast visual acuity at moderate- to low-contrast visual targets was significantly worse in the presence of a glare source in both groups, whereas photopic contrast visual acuity did not change significantly. There were no significant differences between the 2 groups in the mean visual acuity or in photopic or mesopic lighting contrast visual acuity with and without a glare source. Furthermore, there was no significant difference in loss of contrast visual acuity in the presence of glare. Mesopic contrast sensitivity with both acrylic IOLs was impaired significantly in the presence of glare, but the impairment of contrast sensitivity from glare was approximately the same between eyes with a textured-edge IOL and eyes with a round-anterior, sloped-sided edge IOL.

  10. Bearing Tester Data Compilation Analysis, and Reporting and Bearing Math Modeling

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The magnitude and direction of fluid induced torques and forces on the 57 mm bearing cage is considered to be a contributing factor in possible cage instabilities that can produce intermittent high heating in the bearing. Analyses of the fluid forces and torques are presented. Heat generated by viscous fluid work was estimated for two flow diverter configurations and a coolant flow of 10 lbs/sec to support the thermal evaluation of the LOX Bearing Materials Tester. Results of the analysis of the LOX turbopump turbine end bearings are discussed. Coolant velocities for the no. 4 LOX turbopump turbine end bearings were estimated as a function of shaft speed and coolant flow rate. Contact angles and track width data were developed for the 57 mm bearing as functions of shaft speed, and axial and radial loads. The Advanced Dynamics of Rolling Elements (ADORE) computer program was installed on the MSFC UNIVAC 1100 and a test case successfully run. Both the text output and the plotting output were verified. The Bearing Seal and Materials Tester - Test Condition Data Base was developed. The parametric analysis of the operating characteristics of the LOX turbopump pump end bearing using the 45 mm bearing thermal model was begun.

  11. UW VLSI chip tester

    NASA Astrophysics Data System (ADS)

    McKenzie, Neil

    1989-12-01

    We present a design for a low-cost, functional VLSI chip tester. It is based on the Apple MacIntosh II personal computer. It tests chips that have up to 128 pins. All pin drivers of the tester are bidirectional; each pin is programmed independently as an input or an output. The tester can test both static and dynamic chips. Rudimentary speed testing is provided. Chips are tested by executing C programs written by the user. A software library is provided for program development. Tests run under both the Mac Operating System and A/UX. The design is implemented using Xilinx Logic Cell Arrays. Price/performance tradeoffs are discussed.

  12. Usefulness of new wetness tester for diagnosis of dry mouth in disabled patients.

    PubMed

    Kakinoki, Yasuaki; Nishihara, Tatsuji; Arita, Masahiro; Shibuya, Koji; Ishikawa, Masao

    2004-12-01

    The condition of dry mouth is an influential factor in the incidence of caries, periodontal disease, fungal infections, masticatory dysfunctions and denture function. Bedridden elderly and disabled persons often suffer from oral dryness and the aim of this study was to evaluate the usefulness of measuring the amount of moisture in the oral mucosa for clinical diagnosis of dry mouth in this group. The subjects were 20 elderly bedridden individuals, age range 65-89 years old, living in a nursing home and six healthy laboratory researchers, aged 20-46 years old, used as controls. Tongue dorsum moisture measurements were performed using a newly developed wetness tester (L-SALIVO), in which the wet portion was measured after 10 s. Further, clinical diagnosis of dry mouth was carried out using a clinical classification scale of the tongue mucosa (grade range, 0-3). It was possible to measure tongue dorsum moisture in all subjects with the wetness tester. The average moisture value was 0.1+/-0.2 mm in elderly subjects with a dry mouth grade of 2 (n = 8) or 3 (n = 12), while the average moisture value in the control subjects was 3.67+/-1.75 mm with a dry mouth grade of 0 (n = 4) or 1 (n = 2). Tester values and cliniical classification showed a positive co-relationship (r = 0.31, p < 0.05). Our results show that this new tester could be useful for evaluating oral dryness and diagnosing dry mouth.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maestas, J.H.

    The Loopback Tester is an Intel SBC 86/12A Single Board Computer and an Intel SBC 534 Communications Expansion Board configured and programmed to perform various basic or less. These tests include: (1) Data Communications Equipment (DCE) transmit timing detection (2) data rate measurement (3) instantaneous loopback indication and (4) bit error rate testing. It requires no initial setup after plug in, and can be used to locate the source of communications loss in a circuit. It can also be used to determine when crypto variable mismatch problems are the source of communications loss. This report discusses the functionality of themore » Loopback Tester as a diagnostic device. It also discusses the hardware and software which implements this simple yet reliable device.« less

  14. Visual accommodation trainer-tester

    NASA Technical Reports Server (NTRS)

    Randle, Robert J. (Inventor)

    1988-01-01

    An apparatus for training the human visual accommodation system is described. Specifically, the apparatus is useful for training personnel to volitionally control focus to the far point (normally infinity) from a position of myopia due to functional causes. The functional causes could be due, for example, to a behavioral accommodative spasm or the effects of an empty field. The device may also be used to measure accommodation, the accommodation resting position and the near and far points of vision. The device comprises a number of optical elements arranged on a single optical axis. Several of the elements are arranged in order on a movable stage in fixed relationship to each other: a light source, a lens, a target, an aperture and/or a second lens. On a base and in fixed relationship to each other are eyepiece and third lens. A stage generates an image of the target and the stage is movable with respect to the base by means of a knob. The device is utilized for the various training and test functions by following a series of procedural steps, and interchanging the apertures as necessary for the selected procedure.

  15. Spring-Blade Impact Tester

    NASA Technical Reports Server (NTRS)

    Holmes, Alan M.; Champagne, James W.

    1989-01-01

    Record of energy relationships retrieved from compact, portable tester. Spring-blade impact tester developed to support evaluation of tolerance to damage of struts under consideration for use in Space Station. Approach offers potential for determining damage as function of change in relationship between applied and absorbed energies as applied energy successively increased with each impact. Impactor strikes specimen at moment of maximum kinetic energy after spring blades released from cocked position. Concept also provides potential for measuring behavior during impact, and energy relationships retrievable from oscilloscope traces of impact.

  16. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

    PubMed

    Hayashi, Ken; Hirata, Akira; Yoshida, Motoaki; Yoshimura, Koichi; Hayashi, Hideyuki

    2012-08-01

    To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. Case-control study. Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. The visual standards for the selection and retention of astronauts, part 2

    NASA Technical Reports Server (NTRS)

    Allen, M. J.; Levene, J. R.; Heath, G. G.

    1972-01-01

    In preparation for the various studies planned for assessing visual capabilities and tasks in order to set vision standards for astronauts, the following pieces of equipment have been assembled and tested: a spectacle obstruction measuring device, a biometric glare susceptibility tester, a variable vergence amplitude testing device, an eye movement recorder, a lunar illumination simulation chamber, a night myopia testing apparatus, and retinal adaption measuring devices.

  18. Evaluation of a large-scale quantitative respirator-fit testing program for healthcare workers: survey results.

    PubMed

    Wilkinson, Irene J; Pisaniello, Dino; Ahmad, Junaid; Edwards, Suzanne

    2010-09-01

    To present the evaluation of a large-scale quantitative respirator-fit testing program. Concurrent questionnaire survey of fit testers and test subjects. Ambulatory care, home nursing care, and acute care hospitals across South Australia. Quantitative facial-fit testing was performed with TSI PortaCount instruments for healthcare workers (HCWs) who wore 5 different models of a disposable P2 (N95-equivalent) respirator. The questionnaire included questions about the HCW's age, sex, race, occupational category, main area of work, smoking status, facial characteristics, prior training and experience in use of respiratory masks, and number of attempts to obtain a respirator fit. A total of 6,160 HCWs were successfully fitted during the period from January through July 2007. Of the 4,472 HCWs who responded to the questionnaire and were successfully fitted, 3,707 (82.9%) were successfully fitted with the first tested respirator, 551 (12.3%) required testing with a second model, and 214 (4.8%) required 3 or more tests. We noted an increased pass rate on the first attempt over time. Asians (excluding those from South and Central Asia) had the highest failure rate (16.3% [45 of 276 Asian HCWs were unsuccessfully fitted]), and whites had the lowest (9.8% [426 of 4,338 white HCWs]). Race was highly correlated with facial shape. Among occupational groups, doctors had the highest failure rate (13.4% [81 of 604 doctors]), but they also had the highest proportion of Asians. Prior education and/or training in respirator use were not associated with a higher pass rate. Certain facial characteristics were associated with higher or lower pass rates with regard to fit testing, and fit testers were able to select a suitable respirator on the basis of a visual assessment in the majority of cases. For the fit tester, training and experience were important factors; however, for the HCW being fitted, prior experience in respirator use was not an important factor.

  19. Product-Improvement Test (Phase II), Jetcal Tester, Model H119A.

    DTIC Science & Technology

    1969-03-05

    Ao—A0 51 113 ARMY AVIATION ‘Cs’ BOARD FORT tUCKER ALA — P*OOUCTeII ROVEMCNT TEST ( FHAS ~ I I ) . JETCAL TESTER, MODEL M119A~~’ETC(U) MAR S9...Phase i i ) , Jetcal Tester , Model H 119A , USATECOM Project No. 4-6-5011-03 b . No fur ther consideration be given to the TEMPCAL heater probe as a...essen t i a l component of the Jetcal Tester. e. The service manual instruct ions for con t inu i ty te s t ing of EG1 thermocouples be revised to

  20. Inter-Investigator Reliability of Anthropometric Prediction of 1RM Bench Press in College Football Players

    PubMed Central

    SCHUMACHER, RICHARD M.; ARABAS, JANA L.; MAYHEW, JERRY L.; BRECHUE, WILLIAM F.

    2016-01-01

    The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1–2% for circumferences to 4–9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CV<10.7%). Predicted 1RMs for testers (126.9 ± 20.6, 123.4 ± 22.0, and 132.1 ± 28.4 kg, respectively) were not significantly different from actual 1RM (129.2 ± 20.6 kg). Individuals with varying levels of experience appear to have an acceptable level of ability to estimate 1RM bench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press. PMID:27766130

  1. Inter-Investigator Reliability of Anthropometric Prediction of 1RM Bench Press in College Football Players.

    PubMed

    Schumacher, Richard M; Arabas, Jana L; Mayhew, Jerry L; Brechue, William F

    2016-01-01

    The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1-2% for circumferences to 4-9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CV<10.7%). Predicted 1RMs for testers (126.9 ± 20.6, 123.4 ± 22.0, and 132.1 ± 28.4 kg, respectively) were not significantly different from actual 1RM (129.2 ± 20.6 kg). Individuals with varying levels of experience appear to have an acceptable level of ability to estimate 1RM bench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press.

  2. HIV impact on women: gender difference among late testers and advanced HIV infection

    NASA Astrophysics Data System (ADS)

    Sukmawati, N. M. D. D.; Merati, T. P.; Somia, A.; Utama, S.; Gayatri, Y.

    2018-03-01

    This study reported the effect of gender difference on HIV seropositive late testers or advanced infection. A retrospective cohort study of newly diagnosed HIV seropositive based on adatabase in the main referral hospital in Denpasar, Bali, Indonesia from 2004 – 2016. Women and man were categorized as late testers (CD4 ≤ 200 cells/uL and/or AIDS diagnosis ≤ 12 months from first HIV test date). Non-late testers (CD4 > 200 cells/uL and/or no AIDS diagnosis during study period or diagnosis of AIDS >12 months from HIV diagnosis), of reproductive age (13 – 49 years old), and not of reproductive age (>49 years old). Logistic regression was used to estimate risk and its statistical significance. The model consists of gender and age correctly classified 83.5% of cases. Women were almost two times more likely to present as non-late testers compared to men, and reproductive age of 15 – 49 years were 1.5 times more likely to present as non-late testers compared to those with age > 49 years. Women affected by HIV almost in equal as for men. Women and those within reproductive age were more likely to present before the advanced stage compared to men and those aged > 49 years.

  3. An automated digital data collection and analysis system for the Charpy Impact Tester

    NASA Technical Reports Server (NTRS)

    Kohne, Glenn S.; Spiegel, F. Xavier

    1994-01-01

    The standard Charpy Impact Tester has been modified by the addition of a system of hardware and software to improve the accuracy and consistency of measurements made during specimen fracturing experiments. An optical disc, light source, and detector generate signals that indicate the pendulum position as a function of time. These signals are used by a computer to calculate the velocity and kinetic energy of the pendulum as a function of its position.

  4. Using Microsoft Excel[R] to Calculate Descriptive Statistics and Create Graphs

    ERIC Educational Resources Information Center

    Carr, Nathan T.

    2008-01-01

    Descriptive statistics and appropriate visual representations of scores are important for all test developers, whether they are experienced testers working on large-scale projects, or novices working on small-scale local tests. Many teachers put in charge of testing projects do not know "why" they are important, however, and are utterly convinced…

  5. Stereoscopic displays for virtual reality in the car manufacturing industry: application to design review and ergonomic studies

    NASA Astrophysics Data System (ADS)

    Moreau, Guillaume; Fuchs, Philippe

    2002-05-01

    In the car manufacturing industry the trend is to drastically reduce the time-to-market by increasing the use of the Digital Mock-up instead of physical prototypes. Design review and ergonomic studies are specific tasks because they involve qualitative or even subjective judgements. In this paper, we present IMAVE (IMmersion Adapted to a VEhicle) designed for immersive styling review, gaps visualization and simple ergonomic studies. We show that stereoscopic displays are necessary and must fulfill several constraints due to the proximity and size of the car dashboard. The duration fo the work sessions forces us to eliminate all vertical parallax, and 1:1 scale is obviously required for a valid immersion. Two demonstrators were realized allowing us to have a large set of testers (over 100). More than 80% of the testers saw an immediate use of the IMAVE system. We discuss the good and bad marks awarded to the system. Future work include being able to use several rear-projected stereo screens for doors and central console visualization, but without the parallax presently visible in some CAVE-like environments.

  6. Test-retest reliability of auditory brainstem responses to chirp stimuli in newborns.

    PubMed

    Cobb, Kensi M; Stuart, Andrew

    2014-11-01

    The purpose of this study was to examine the test-retest reliability of auditory brainstem responses (ABRs) to air- and bone-conducted chirp stimuli in newborns as a function of intensity. A repeated measures quasi-experimental design was employed. Thirty healthy newborns participated. ABRs were evoked using 60, 45, and 30 dB nHL air-conducted CE-Chirps and 45, 30, and 15 dB nHL bone-conducted CE-Chirps at a rate of 57.7/s. Measures were repeated by a second tester. Statistically significant correlations (p <.0001) and predictive linear relations (p <.0001) were found between testers for wave V latencies and amplitudes to air- and bone-conducted CE-Chirps. There were also no statistically significant differences between testers with wave V latencies and amplitudes to air- and bone-conducted CE-Chirps (p >.05). As expected, significant differences in wave V latencies and amplitudes were seen as a function of stimulus intensity for air- and bone-conducted CE-Chirps (p <.0001). These results suggest that ABRs to air- and bone-conducted CE-Chirps can be reliably repeated in newborns with different testers. The CE-Chirp may be valuable for both screening and diagnostic audiologic assessments of newborns.

  7. System architecture of a gallium arsenide one-gigahertz digital IC tester

    NASA Technical Reports Server (NTRS)

    Fouts, Douglas J.; Johnson, John M.; Butner, Steven E.; Long, Stephen I.

    1987-01-01

    The design for a 1-GHz digital integrated circuit tester for the evaluation of custom GaAs chips and subsystems is discussed. Technology-related problems affecting the design of a GaAs computer are discussed, with emphasis on the problems introduced by long printed-circuit-board interconnect. High-speed interface modules provide a link between the low-speed microprocessor and the chip under test. Memory-multiplexer and memory-shift register architectures for the storage of test vectors are described in addition to an architecture for local data storage consisting of a long chain of GaAs shift registers. The tester is constructed around a VME system card cage and backplane, and very little high-speed interconnect exists between boards. The tester has a three part self-test consisting of a CPU board confidence test, a main memory confidence test, and a high-speed interface module functional test.

  8. 7 CFR 1436.6 - Eligible storage or handling equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...

  9. 7 CFR 1436.6 - Eligible storage or handling equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...

  10. 7 CFR 1436.6 - Eligible storage or handling equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...

  11. 7 CFR 1436.6 - Eligible storage or handling equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... stored eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...

  12. 7 CFR 1436.6 - Eligible storage or handling equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... eligible facility loan commodity, such as cleaners, moisture testers, and heat detectors; (4) Electrical... moisture testers, and heat detectors; (vii) Electrical equipment, including labor and materials for..., but are not limited to, the following: An insulated cement slab floor, insulation for walls and...

  13. Mesostructural investigation of micron-sized glass particles during shear deformation - An experimental approach vs. DEM simulation

    NASA Astrophysics Data System (ADS)

    Torbahn, Lutz; Weuster, Alexander; Handl, Lisa; Schmidt, Volker; Kwade, Arno; Wolf, Dietrich E.

    2017-06-01

    The interdependency of structure and mechanical features of a cohesive powder packing is on current scientific focus and far from being well understood. Although the Discrete Element Method provides a well applicable and widely used tool to model powder behavior, non-trivial contact mechanics of micron-sized particles demand a sophisticated contact model. Here, a direct comparison between experiment and simulation on a particle level offers a proper approach for model validation. However, the simulation of a full scale shear-tester experiment with micron-sized particles, and hence, validating this simulation remains a challenge. We address this task by down scaling the experimental setup: A fully functional micro shear-tester was developed and implemented into an X-ray tomography device in order to visualize the sample on a bulk and particle level within small bulk volumes of the order of a few micro liter under well-defined consolidation. Using spherical micron-sized particles (30 μm), shear tests with a particle number accessible for simulations can be performed. Moreover, particle level analysis allows for a direct comparison of experimental and numerical results, e.g., regarding structural evolution. In this talk, we focus on density inhomogeneity and shear induced heterogeneity during compaction and shear deformation.

  14. Finger wear detection for production line battery tester

    DOEpatents

    Depiante, Eduardo V.

    1997-01-01

    A method for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change.

  15. Finger wear detection for production line battery tester

    DOEpatents

    Depiante, E.V.

    1997-11-18

    A method is described for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change. 9 figs.

  16. Long-Term Performance Evaluation of Asphalt Surface Treatments: Product Placement

    DTIC Science & Technology

    2010-02-01

    20 Wheeler-Sack Army Airfield, Fort Drum , New York ...............................................................28 4...Grip Tester underside view ................................................................................ 6 Figure 3. Rotating disc of Dynamic...measures pavement friction using the braked -wheel, fixed-slip principle. Two wheels support the Grip Tester on a drive axle, while a measuring wheel with

  17. 49 CFR 229.25 - Tests: Every periodic inspection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... dead-weight tester or a test gauge designed for this purpose. (b) All electrical devices and visible...) Steam pressure gauges shall be tested by comparison with a dead-weight tester or a test gauge designed... 49 Transportation 4 2011-10-01 2011-10-01 false Tests: Every periodic inspection. 229.25 Section...

  18. Ability of walking without a walking device in patients with spinal cord injury as determined using data from functional tests

    PubMed Central

    Poncumhak, Puttipong; Saengsuwan, Jiamjit; Amatachaya, Sugalya

    2014-01-01

    Background/Objectives More than half of independent ambulatory patients with spinal cord injury (SCI) need a walking device to promote levels of independence. However, long-lasting use of a walking device may introduce negative impacts for the patients. Using a standard objective test relating to the requirement of a walking device may offer a quantitative criterion to effectively monitor levels of independence of the patients. Therefore, this study investigated (1) ability of the three functional tests, including the five times sit-to-stand test (FTSST), timed up and go test (TUGT), and 10-meter walk test (10MWT) to determine the ability of walking without a walking device, and (2) the inter-tester reliability of the tests to assess functional ability in patients with SCI. Methods Sixty independent ambulatory patients with SCI, who walked with and without a walking device (30 subjects/group), were assessed cross-sectionally for their functional ability using the three tests. The first 20 subjects also participated in the inter-tester reliability test. Results The time required to complete the FTSST <14 seconds, the TUGT < 18 seconds, and the 10MWT < 6 seconds had good-to-excellent capability to determine the ability of walking without a walking device of subjects with SCI. These tests also showed excellent inter-tester reliability. Conclusions Methods of clinical evaluation for walking are likely performed using qualitative observation, which makes the results difficult to compare among testers and test intervals. Findings of this study offer a quantitative target criterion or a clear level of ability that patients with SCI could possibly walk without a walking device, which would benefit monitoring process for the patients. PMID:24621030

  19. Inducible error-prone repair in B. subtilis. Progress report, September 1, 1978-August 31, 1979. [Role in mutagenesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yasbin, R E

    1979-01-01

    The mechanism of activation and the mode of action of the SOS system in the bacterium Bacillus subtilis is under study. Interesting aspects of the SOS system in B. subtilis are: (1) the differences between SOS functions in this bacterium and in the enteric bacteria; (2) the spontaneous activation of SOS functions in component cells; and (3) the difficulty in obtaining consistent results for mutation studies in this bacterium. In order to characterize the SOS system of B. subtilis, it was proposed to: (1) isolate bacteria mutated in genes controlling various repair function; (2) investigate inducible repair; (3) determine themore » role of endogeneous Bacillus prophages in SOS functions; and (4) develop a tester system for potential carcinogens from competent Bacillus subtilis cells. Research has been able to: (1) isolate strains of B. subtilis in which the endogeneous prophages have been removed or neutralized; (2) demonstrate the association of one SOS function with prophage SPB; (3) demonstrate that the survival of uv-irradiated B. subtilis is not significantly altered by the removal and neutralization of the endogeneous prophages; (4) develop competant B. subtilis into a tester system; and (5) show that DNA polymerase III is absolutely necessary for W reactivation. In addition, uv and mitomycin C resistant mutants have been isolated and inducible postreplication repair in excision-repair deficient mutants of B. subtilis has been studied. The last two results are somewaht confusing but highly exciting in regards to DNA repair mechanisms in B. subtilis.« less

  20. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    PubMed

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  1. Test strategies for industrial testers for converter controls equipment

    NASA Astrophysics Data System (ADS)

    Oleniuk, P.; Di Cosmo, M.; Kasampalis, V.; Nisbet, D.; Todd, B.; Uznański, S.

    2017-04-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.

  2. The Design of a Four Square Gear Tester for Noise and Vibration Measurements.

    DTIC Science & Technology

    1986-12-01

    Four Square Gear Tester ...... . 25 2.3 The Speed-Torque Relationship of Contraves Blower Ventilated Motor ....... ..................... ... 31 2.4...The Speed-Torque Relationship of Contraves Self- Ventilated Motor ....... ..................... ... 32 2.5 The Contraves Motor...34 2.6 The Contraves Motor Mounted Blower ... ............ ... 35 2.7 The Fixed-Fixed End Condition (to determine the natural frequency of the

  3. Lessons Learned from JTA Tester Safety Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. L. Bierbaum

    2001-05-01

    EP401575, Issue C, calls out a requirement to perform safety studies for testers that are used to accept Joint Test Assembly (JTA) product at Pantex (Reference 1). The underlying motivation is to ensure that personnel hazards due to inadvertent initiation of electro-explosive devices (EEDs) during JTA testing are understood and minimized. Studies have been performed on the B61-7/11 JTA, B61-3/4/10 JTA, B83 JTA, and W76 Type 2F testers at Pantex (References 2-5). Each of these studies includes an examination of the relevant Pantex tester as well as the instrumentation and War Reserve (WR) hardware. In performing these analyses, several themesmore » have emerged that could be useful for the Phase 6.3 design efforts for the weapons, the associated instrumentation, and the JTA testers. This report summarizes the lessons learned from these studies. Note that in some cases, the recommendations provided below to enhance safety during JTA testing operations (e.g., adding isolation resistors in the monitoring lines) may result in a reliability degradation or other surety impact. Thus it is important to consider these lessons learned in the context of the overall design and to make tradeoffs in light of the integrated surety objectives. The lessons learned are listed in five different categories, summarized as: (1) Instrumentation considerations; (2) WR design considerations; (3) Tester considerations; (4) Administrative procedures during JTA assembly; and (5) Administrative procedures prior to and during JTA testing. The first three focus on minimizing the probability of inadvertent application of power to EED initiation lines due to component, connector, and assembly failures. The last two describe procedural steps that can be taken at Pantex to either minimize the risk (e.g., by ensuring that tester power supplies cannot supply excessive power to the unit under test) or to mitigate the consequences of unexpected EED initiation (e.g., by instructing test operators to avoid standing in areas where they could be at risk in the event of EED initiation).« less

  4. Enhanced Master Controller Unit Tester

    NASA Technical Reports Server (NTRS)

    Benson, Patricia; Johnson, Yvette; Johnson, Brian; Williams, Philip; Burton, Geoffrey; McCoy, Anthony

    2007-01-01

    The Enhanced Master Controller Unit Tester (EMUT) software is a tool for development and testing of software for a master controller (MC) flight computer. The primary function of the EMUT software is to simulate interfaces between the MC computer and external analog and digital circuitry (including other computers) in a rack of equipment to be used in scientific experiments. The simulations span the range of nominal, off-nominal, and erroneous operational conditions, enabling the testing of MC software before all the equipment becomes available.

  5. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallerman, G.; Gray, R.J.

    The design and testing procedures of two elevatedtemperature hardness testers are described. One device uses a Rockwell tester with a large vertical capacity and a load range of 15 to 150 kg. The tester is equipped with a 900 deg C heating chamber which maintains an argon atmosphere over the specimen and can be laterally displaced by a cross-feed mechanism to allow repeated hardness readings to be made on the same specimen. The second instrument is a microindentation hardness tester for hardness determinations to a maximum temperature of 1000 deg C in vacuum of 10/sup -4/ to 10/sup -5/ torr.more » A deadweight loading system with a 136-deg diamond pyramid (Vickers) indenter, capable of delivering static loads between 0.150 and 3 kg, is contained within the vacuum chamber to avoid calibration problems that arise when loads are applied from outside the vacuum system. The microindentation hardness tester allows up to 100 determinations to be made on a single specimen without opening the test chamber. The applicability of the testers is illustrated by elevatedtemperature hardness measurements on several commercial alloys, a group of niobium-vanadium alloys, and by the changes in hardness occurring at the transformation temperatures of iron and steel. Hardness values of Haynes alloy No. 25 were determined at the temperatures of aging and are shown to be different from those obtained with the customary method of investigating age hardening. The testing is currently being used to aid and accelerate the development of alloys with desirable high-temperature properties. (auth)« less

  7. [Comparison of the dietary phytosterols intake and serum lipids content in elderly women from three cities of China].

    PubMed

    Han, Jun-hua; Li, Yan-ping; Men, Jian-hua; Yu, Wen-tao; Yang, Yue-xin

    2009-12-01

    To investigate the dietary phytosterol intake of elderly women in three different cities of China, and to compare the main dietary sources, so that to discuss the relationship of dietary phytosterol intake and serum lipids. Based on the dietary pattern, women more than 50 years old from Beijing, Hefei and Urumchi were chosen as testers, 80 - 100 people for each city respectively. The dietary survey was done by continues 24 hours review of two days, the plant food were collected and the phytosterol content (include beta-sitosterol, campesterol, stigmasterol, sitostanol) were analyzed by GC methods, the total phytosterols content were calculated. The dietary phytosterol intake were calculated and serum lipids were also analyzed in all the testers. Testers from Beijing, Hefei and Urumchi were 100, 101 and 84 respectively. The average dietary phytosterol intake of people in Beijing and Hefei were 340.3 mg/d and 313.5 mg/d, the main sources were plant oil and cereals, while the average dietary phytosterol intake of people in Urumchi were 550.4 mg/d, higher than the other two cities (t values were 9.369, 10.420, respectively, both P values < 0.01), the main source in Urumchi was cereal (provide 53.1% of the total phytosterol intake). The laboratory results showed, testers in Urumchi had significantly lower serum TC content ((4.04 +/- 0.78) mmol/L) than that in Beijing ((4.89 +/- 0.91) mmol/L) and Hefei ((4.71 +/- 0.83) mmol/L) (t value were 6.766 and 5.401 respectively, both P values < 0.01); serum TG content in Urumchi((1.01 +/- 0.48) mmol/L) was also lower than that in Beijing ((1.31 +/- 0.53) mmol/L) and Hefei ((1.66 +/- 0.75) mmol/L) (t values were 3.343 and 7.293 respectively, both P values < 0.01); the serum glucose is also lower in testers in Urumchi ((5.02 +/- 2.18) mmol/L) compared with testers in Beijing ((5.69 +/- 1.53) mmol/L, t = 2.561, P < 0.05) and Hefei ((5.78 +/- 1.53) mmol/L, t = 2.934, P < 0.01). Different dietary pattern result in significantly different dietary phytosterol intake in elder women in three cities, higher, phytosterol intake seemed to contribute to lower serum lipids.

  8. Test verification and design of the bicycle frame parameters

    NASA Astrophysics Data System (ADS)

    Zhang, Long; Xiang, Zhongxia; Luo, Huan; Tian, Guan

    2015-07-01

    Research on design of bicycles is concentrated on mechanism and auto appearance design, however few on matches between the bike and the rider. Since unreasonable human-bike relationship leads to both riders' worn-out joints and muscle injuries, the design of bicycles should focus on the matching. In order to find the best position of human-bike system, simulation experiments on riding comfort under different riding postures are done with the lifemode software employed to facilitate the cycling process as well as to obtain the best position and the size function of it. With BP neural network and GA, analyzing simulation data, conducting regression analysis of parameters on different heights and bike frames, the equation of best position of human-bike system is gained at last. In addition, after selecting testers, customized bikes based on testers' height dimensions are produced according to the size function. By analyzing and comparing the experimental data that are collected from testers when riding common bicycles and customized bicycles, it is concluded that customized bicycles are four times even six times as comfortable as common ones. The equation of best position of human-bike system is applied to improve bikes' function, and the new direction on future design of bicycle frame parameters is presented.

  9. Octopuses (Enteroctopus dofleini) recognize individual humans.

    PubMed

    Anderson, Roland C; Mather, Jennifer A; Monette, Mathieu Q; Zimsen, Stephanie R M

    2010-01-01

    This study exposed 8 Enteroctopus dofleini separately to 2 unfamiliar individual humans over a 2-week period under differing circumstances. One person consistently fed the octopuses and the other touched them with a bristly stick. Each human recorded octopus body patterns, behaviors, and respiration rates directly after each treatment. At the end of 2 weeks, a body pattern (a dark Eyebar) and 2 behaviors (reaching arms toward or away from the tester and funnel direction) were significantly different in response to the 2 humans. The respiration rate of the 4 larger octopuses changed significantly in response to the 2 treatments; however, there was no significant difference in the 4 smaller octopuses' respiration. Octopuses' ability to recognize humans enlarges our knowledge of the perceptual ability of this nonhuman animal, which depends heavily on learning in response to visual information. Any training paradigm should take such individual recognition into consideration as it could significantly alter the octopuses' responses.

  10. Development of a second generation rolling contact fatigue tester

    NASA Astrophysics Data System (ADS)

    Deshmukh, Satyam U.

    Contact fatigue failure has been in research since the early twentieth century. The need for a second generation sliding-rolling contact fatigue tester was proposed by Gregory Dvorak and Dr. Marcellin Zahui. The first generation RCF tester was used for testing super finishing processes for gear surfaces. The second generation RCF tester was funded by the Advanced Engineering Materials lab of University of North Dakota. Verification of the second generation Rolling Contact Fatigue Tester will be discussed in this thesis including the design details, assembly and testing procedure and to discuss its different parameters. The tester will have the capability of testing hollow specimens using a bobbin eddy current testing probe. This tester will allow a wide range of experiments and is not built for one specific purpose. An eddy current device is used for detecting cracks. The loading force is applied using hydraulic cylinders and a hydraulic power unit. Before testing began, the machine was run for some time at full speed. A lot of minor problems were detected and fixed. Three specimens of AISI 8620 were tested in this tester. All tests gave results matching with some of the other well-known RCF testers. These tests were performed to evaluate mechanical limits of the tester and to evaluate the software performance of the tester.

  11. 46 CFR 30.10-27 - Flashpoint-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...

  12. 46 CFR 30.10-27 - Flashpoint-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... gives off a flammable vapor when heated in an open-cup tester. For the purpose of the regulations in... with an open-cup tester, as follows: Table 30.10-27—Equivalent Flashpoints [In degrees Farenheit] Open-cup tester Tag closed-cup tester (A.S.T.M.) Pensky-Martens closed tester (A.S.T.M.) 80 75 150 140 ...

  13. Spring performance tester for miniature extension springs

    DOEpatents

    Salzbrenner, Bradley; Boyce, Brad

    2017-05-16

    A spring performance tester and method of testing a spring are disclosed that has improved accuracy and precision over prior art spring testers. The tester can perform static and cyclic testing. The spring tester can provide validation for product acceptance as well as test for cyclic degradation of springs, such as the change in the spring rate and fatigue failure.

  14. Postural sensorimotor training versus sham exercise in physiotherapy of patients with chronic non-specific low back pain: An exploratory randomised controlled trial

    PubMed Central

    Wirth, Brigitte

    2018-01-01

    Sensorimotor training (SMT) is popularly applied as exercise in rehabilitation settings, particularly for musculoskeletal pain. With insufficient evidence on its effect on pain and function, this exploratory randomised controlled trial investigated the potential effects of SMT in rehabilitation of chronic non-specific low back pain. Two arms received 9x30 minutes physiotherapy with added interventions: The experimental arm received 15 minutes of postural SMT while the comparator arm performed 15 minutes of added sub-effective low-intensity training. A treatment blinded tester assessed outcomes at baseline 2–4 days prior to intervention, pre- and post-intervention, and at 4-week follow-up. Main outcomes were pain and functional status assessed with a 0–100mm visual analogue scale and the Oswestry Disability Questionnaire. Additionally, postural control was analysed using a video-based tracking system and a pressure plate during perturbed stance. Robust, nonparametric multivariate hypothesis testing was performed. 22 patients (11 females, aged 32 to 75 years) with mild to moderate chronic pain and functional limitations were included for analysis (11 per arm). At post-intervention, average values of primary outcomes improved slightly, but not to a clinically relevant or statistically significant extent. At 4-week follow-up, there was a significant improvement by 12 percentage points (pp) on the functional status questionnaire in the SMT-group (95% confidence intervall (CI) = 5.3pp to 17.7pp, p < 0.001) but not in the control group (4 pp improvement, CI = 11.8pp to 19.2pp). However, group-by-time interaction effects for functional status (Q = 3.3, 19 p = 0.07) and pain (Q = 0.84, p = 0.51) were non-significant. Secondary kinematic outcomes did not change over time in either of the groups. Despite significant improvement of functional status after SMT, overall findings of this exploratory study suggest that SMT provides no added benefit for pain reduction or functional improvement in patients with moderate chronic non-specific low back pain. Trial registration: ClinicalTrials.gov NCT02304120 and related study protocol, DOI: 10.1186/1471-2474-15-382. PMID:29522571

  15. An automated testing tool for traffic signal controller functionalities.

    DOT National Transportation Integrated Search

    2010-03-01

    The purpose of this project was to develop an automated tool that facilitates testing of traffic controller functionality using controller interface device (CID) technology. Benefits of such automated testers to traffic engineers include reduced test...

  16. Strength and Structure of Ga1-xInx as Alloys

    DTIC Science & Technology

    1986-04-01

    fixtures were ordered and received. An existing furnace and retort will be used to surround the compression fixture. The sample will be positioned in a B203...oncerns the experimental measurement of the flow stress and hardness as a function of temperature and In content:. High mprare hardns testing is used ...approximately 1/3 of the hardness 4 value9 so the latter indicates expected trends for yield stress. flWI1AL WORK The hardess tester used in this study was

  17. Effect of variable tinted spectacle lenses on visual performance in control subjects.

    PubMed

    Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M

    2002-04-01

    To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.

  18. Single wheel testers, single track testers, and instrumented tractors

    USDA-ARS?s Scientific Manuscript database

    Single wheel testers and single track testers are used for determining tractive performance characteristics of tires and tracks. Instrumented tractors are useful in determining the tractive performance of tractors. These machines are also used for determining soil-tire and soil-track interactions,...

  19. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.

    PubMed

    Stuempfle, Kristin J.; Drury, Daniel G.

    2003-12-01

    OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.

  20. The validity and intra-tester reliability of markerless motion capture to analyse kinematics of the BMX Supercross gate start.

    PubMed

    Grigg, Josephine; Haakonssen, Eric; Rathbone, Evelyne; Orr, Robin; Keogh, Justin W L

    2017-11-13

    The aim of this study was to quantify the validity and intra-tester reliability of a novel method of kinematic measurement. The measurement target was the joint angles of an athlete performing a BMX Supercross (SX) gate start action through the first 1.2 s of movement in situ on a BMX SX ramp using a standard gate start procedure. The method employed GoPro® Hero 4 Silver (GoPro Inc., USA) cameras capturing data at 120 fps 720 p on a 'normal' lens setting. Kinovea 0.8.15 (Kinovea.org, France) was used for analysis. Tracking data was exported and angles computed in Matlab (Mathworks®, USA). The gold standard 3D method for joint angle measurement could not safely be employed in this environment, so a rigid angle was used. Validity was measured to be within 2°. Intra-tester reliability was measured by the same tester performing the analysis twice with an average of 55 days between analyses. Intra-tester reliability was high, with an absolute error <6° and <9 frames (0.075 s) across all angles and time points for key positions, respectively. The methodology is valid within 2° and reliable within 6° for the calculation of joint angles in the first ~1.25 s.

  1. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers

    PubMed Central

    Drury, Daniel G.

    2003-01-01

    Objective: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. Design and Setting: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. Subjects: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. Measurements: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. Results: Refractometer measurements were consistent between trials (R = .998) and among testers; hydrometer measurements were consistent between trials (R = .987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 ± 0.006) and reagent-strip (1.017 ± 0.007) measurements were significantly higher than refractometer (1.015 ± 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R = .869) and low between refractometry and reagent strips (R = .573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. Conclusions: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process. PMID:14737213

  2. 21 CFR 870.5325 - Defibrillator tester.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...

  3. 21 CFR 870.5325 - Defibrillator tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...

  4. 21 CFR 870.5325 - Defibrillator tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...

  5. 21 CFR 870.5325 - Defibrillator tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...

  6. 21 CFR 870.5325 - Defibrillator tester.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Defibrillator tester. 870.5325 Section 870.5325...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5325 Defibrillator tester. (a) Identification. A defibrillator tester is a device that is connected to the output of a...

  7. 21 CFR 882.1410 - Electroencephalograph electrode/lead tester.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...

  8. 21 CFR 882.1410 - Electroencephalograph electrode/lead tester.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...

  9. 21 CFR 882.1410 - Electroencephalograph electrode/lead tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electroencephalograph electrode/lead tester. 882... Electroencephalograph electrode/lead tester. (a) Identification. An electroencephalograph electrode/lead tester is a device used for testing the impedance (resistance to alternating current) of the electrode and lead...

  10. New insights into the diagnosis and treatment of dry eye.

    PubMed

    Dogru, Murat; Tsubota, Kazuo

    2004-04-01

    Over the past decade, numerous advances have been made in relation to dry eye diagnostic markers, technologies, and treatment options. The mainstay of treatment of dry eye is the use of artificial tear solutions and punctum plugs. A goal is the development of agents that provide symptomatic treatment and, at the same time, improve ocular surface keratinization. It is the authors' opinion that the functional visual acuity tester and the new tear stability analysis system will be widely used to improve diagnosis and evaluate treatment outcomes in KCS. Advances in treatment will utilize anti-inflammatory agents, immune suppressants such as Cyclosporin A and FK-506, growth hormones, androgens, topical mucins and ocular surface stimulating drugs, like INS365. Although aqueous-deficient dry eye is most commonly not associated with Sjogren syndrome (SS), aqueous-deficient dry eye is often most severe in patients with SS; thus, this article focuses mainly on SS-associated dry eye.

  11. Contrast visual acuity in patients with retinitis pigmentosa assessed by a contrast sensitivity tester.

    PubMed

    Oishi, Maho; Nakamura, Hajime; Hangai, Masanori; Oishi, Akio; Otani, Atsushi; Yoshimura, Nagahisa

    2012-01-01

    To assess contrast visual acuity (CVA) in patients with retinitis pigmentosa (RP) and compare the result with standard visual acuity (VA), retinal thickness, status of inner segment/outer segment junction, and central visual field. Thirty-nine eyes of 39 patients with RP and 39 eyes of 39 healthy individuals were studied. To see the difference in CVA between RP patients and normal controls, only subjects with standard VA of 1.0 (20/20) or better were included. This was a cross-sectional study. CVA in various light conditions was measured with CAT-2000 and was compared between patients and controls. CVA of patients was further analyzed for association with other parameters including foveal retinal thickness, outer nuclear layer thickness, the status of inner segment/outer segment junction measured with optical coherence tomography (OCT), and visual field mean deviation (MD) measured with Humphrey field analyzer 10-2 program. CVA impairment was evident in RP patients compared to controls (P < 0.01, in all measurement conditions). Multivariate analysis showed association of logarithm of the minimum angle of resolution (logMAR) with CVAs in several conditions. None of the OCT measurements was associated with CVA. When patients were divided into three groups based on MD, the most advanced group (MD worse than or equal to -20 dB) showed impairment of mesopic CVA (P < 0.05, under mesopic condition of 100% without glare, with glare, and 25% without glare). CVA impairment was confirmed in RP patients, especially in advanced cases. CVA measured with CAT-2000 may be a useful tool for assessing foveal function in RP patients.

  12. Portable Weld Tester.

    ERIC Educational Resources Information Center

    Eckert, Douglas

    This training manual, which was developed for employees of an automotive plant, is designed to teach trainees to operate a portable weld tester (Miyachi MM-315). In chapter 1, the weld tester's components are illustrated and described, and the procedure for charging its batteries is explained. Chapter 2 illustrates the weld tester's parts,…

  13. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  14. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  15. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  16. A simplified ductile-brittle transition temperature tester

    NASA Technical Reports Server (NTRS)

    Arias, A.

    1973-01-01

    The construction and operation of a versatile, simplified bend tester is described. The tester is usable at temperatures from - 192 to 650 C in air. Features of the tester include a single test chamber for cryogenic or elevated temperatures, specimen alining support rollers, and either manual or motorized operation.

  17. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  18. 21 CFR 886.1170 - Color vision tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision tester. 886.1170 Section 886.1170...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1170 Color vision tester. (a) Identification. A color vision tester is a device that consists of various colored materials, such as colored yarns...

  19. 21 CFR 874.1090 - Auditory impedance tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Auditory impedance tester. 874.1090 Section 874...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1090 Auditory impedance tester. (a) Identification. An auditory impedance tester is a device that is intended to change the air pressure in the...

  20. 21 CFR 874.1090 - Auditory impedance tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Auditory impedance tester. 874.1090 Section 874...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1090 Auditory impedance tester. (a) Identification. An auditory impedance tester is a device that is intended to change the air pressure in the...

  1. The reliability of knee joint position testing using electrogoniometry

    PubMed Central

    Piriyaprasarth, Pagamas; Morris, Meg E; Winter, Adele; Bialocerkowski, Andrea E

    2008-01-01

    Background The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric® electrogoniometer. The clinical utility of electrogoniometry was also addressed. Methods The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. Results In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58–0.71 in supine, 0.68–0.79 in sitting and 0.57–0.80 in standing. The standard error of measurement between testers was less than 3.55° and the limits of agreement ranged from -12.51° to 12.21°. Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75–0.76 in supine, 0.86–0.87 in sitting and 0.87–0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7° and the limits of agreement ranged from -8.13° to 7.90°. The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5°. Conclusion Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer. PMID:18211714

  2. Intertester reliability of the acceptable noise level.

    PubMed

    Gordon-Hickey, Susan; Adams, Elizabeth; Moore, Robert; Gaal, Ashley; Berry, Katie; Brock, Sommer

    2012-01-01

    The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background noise. Measurement of ANL relies on the tester and listener to follow the instructions set forth. To date, no research has explored the reliability of ANL as measured across clinicians or testers. To examine the intertester reliability of ANL. A descriptive quasi-experimental reliability study was completed. ANL was measured for one group of listeners by three testers. Three participants served as testers. Each tester was familiar with basic audiometry. Twenty-five young adults with normal hearing served as listeners. Each tester was stationed in a laboratory with the needed equipment. Listeners were instructed to report to these laboratories in a random order provided by the experimenters. The testers assessed most comfortable listening level (MCL) and background noise level (BNL) for all 25 listeners. Intraclass correlation coefficients were significant and revealed that MCL, BNL, and ANLs are reliable across testers. Additionally, one-way ANOVAs for MCL, BNL, and ANL were not significant. These findings indicate that MCL, BNL, and ANL do not differ significantly when measured by different testers. If the ANL instruction set is accurately followed, ANL can be reliably measured across testers, laboratories, and clinics. Intertester reliability of ANL allows for comparison across ANLs measured by different individuals. Findings of the present study indicate that tester reliability can be ruled out as a factor contributing to the disparity of mean ANLs reported in the literature. American Academy of Audiology.

  3. Rocketdyne LOX bearing tester program

    NASA Technical Reports Server (NTRS)

    Keba, J. E.; Beatty, R. F.

    1988-01-01

    The cause, or causes, for the Space Shuttle Main Engine ball wear were unknown, however, several mechanisms were suspected. Two testers were designed and built for operation in liquid oxygen to empirically gain insight into the problems and iterate solutions in a timely and cost efficient manner independent of engine testing. Schedules and test plans were developed that defined a test matrix consisting of parametric variations of loading, cooling or vapor margin, cage lubrication, material, and geometry studies. Initial test results indicated that the low pressure pump thrust bearing surface distress is a function of high axial load. Initial high pressure turbopump bearing tests produced the wear phenomenon observed in the turbopump and identified an inadequate vapor margin problem and a coolant flowrate sensitivity issue. These tests provided calibration data of analytical model predictions to give high confidence in the positive impact of future turbopump design modification for flight. Various modifications will be evaluated in these testers, since similar turbopump conditions can be produced and the benefit of the modification will be quantified in measured wear life comparisons.

  4. Defining Assessment Literacy: Is it Different for Language Testers and Non-Language Testers?

    ERIC Educational Resources Information Center

    Jeong, Heejeong

    2013-01-01

    Language assessment courses (LACs) are taught by professionals who have majored in the area of language testing (language testers or LTs), but also by others who come from different language-related majors (non-language testers, non-LTs). Different language assessment courses may be developed, depending on who teaches the course and the…

  5. Improved wear resistance of functional diamond like carbon coated Ti-6Al-4V alloys in an edge loading conditions.

    PubMed

    Choudhury, Dipankar; Lackner, Jürgen M; Major, Lukasz; Morita, Takehiro; Sawae, Yoshinori; Bin Mamat, Azuddin; Stavness, Ian; Roy, Chanchal K; Krupka, Ivan

    2016-06-01

    This study investigates the durability of functional diamond-like carbon (DLC) coated titanium alloy (Ti-6Al-4V) under edge loading conditions for application in artificial hip joints. The multilayered (ML) functional DLC coatings consist of three key layers, each of these layers were designed for specific functions such as increasing fracture strength, adapting stress generation and enhancing wear resistance. A 'ball-on-disk' multi-directional wear tester was used in the durability test. Prior to the wear testing, surface hardness, modulus elasticity and Raman intensity were measured. The results revealed a significant wear reduction to the DLC coated Ti-6Al-4V disks compared to that of non-coated Ti-6Al-4V disks. Remarkably, the counterpart Silicon Nitride (Si3N4) balls also yielded lowered specific wear rate while rubbed against the coated disks. Hence, the pairing of a functional multilayered DLC and Si3N4 could be a potential candidate to orthopedics implants, which would perform a longer life-cycle against wear caused by edge loading. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Testing Methods for Integrated Circuit Chips.

    DTIC Science & Technology

    1986-03-27

    DWf <I IAV ~IMi MORY OUT LOGIC~~ IPOGRAM ASYC S’E4i E...* 16o, CO% T ROL CO%TROL 32 Figure 2 . 14 VLSI Tester Block Diagram. registers, memory and test...neral-pIurpos’ processor wi th standard bus- inte-rfaco se-rves as,- th- test control Ii’r and ( 2 ) a c-ustom VLSI test Controller inti-rfacing direc(_t1...Engineering 2 WTWTY ABSTRACT Provision for the functional testing of fabricated VLSI chips frequently involves as much design effort as the orig- _ inal

  7. STS-59 Space Shuttle mission report

    NASA Technical Reports Server (NTRS)

    Fricke, Robert W., Jr.

    1994-01-01

    The STS-59 Space Shuttle Program Mission Report summarizes the Payload activities as well as the Orbiter, External Tank (ET), Solid Rocket Booster (SRB), Redesigned Solid Rocket Motor (RSRM), and the Space Shuttle main engine (SSME) systems performance during the sixty-second flight of the Space Shuttle Program and sixth flight of the Orbiter vehicle Endeavor (OV-105). In addition to the Orbiter, the flight vehicle consisted of an ET designated as ET-63; three SSME's which were designated as serial numbers 2028, 2033, and 2018 in positions 1, 2, and 3, respectively; and two SRB's which were designated BI-065. The RSRM's that were installed in each SRB were designated as 360W037A (welterweight) for the left SRB, and 360H037B (heavyweight) for the right SRB. This STS-59 Space Shuttle Program Mission Report fulfills the Space Shuttle Program requirement as documented in NSTS 07700, Volume 8, Appendix E. That document requires that each major organizational element supporting the Program report the results of its hardware evaluation and mission performance plus identify all related in-flight anomalies. The primary objective of the STS-59 mission was to successfully perform the operations of the Space Radar Laboratory-1 (SRL-1). The secondary objectives of this flight were to perform the operations of the Space Tissue Loss-A (STL-A) and STL-B payloads, the Visual Function Tester-4 (VFT-4) payload, the Shuttle Amateur Radio Experiment-2 (SAREX-2) experiment, the Consortium for Materials Development in Space Complex Autonomous Payload-4 (CONCAP-4), and the three Get-Away Special (GAS) payloads.

  8. Growth and studies of cyclohexylammonium 4-methoxy benzoate single crystal for nonlinear optical applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sathya, P.; Gopalakrishnan, R., E-mail: krgkrishnan@annauniv.edu

    2015-06-24

    Cyclohexylammonium 4-Methoxy Benzoate (C4MB) was synthesised and the functional groups were confirmed by FTIR analysis. The purified C4MB (by repeated recrystallisation) was used for single crystal growth. Single crystal of cyclohexylammonium 4-methoxy benzoate was successfully grown by slow evaporation solution growth method at ambient temperature. Structural orientations were determined from single crystal X-ray diffractometer. Optical absorption and cut off wavelength were identified by UV-Visible spectroscopy. Thermal stability of the crystal was studied from thermogravimetric and differential thermal analyses curves. Mechanical stability of the grown crystal was analysed by Vicker’s microhardness tester. The Second Harmonic Generation (SHG) study revealed that themore » C4MB compound exhibits the SHG efficiency 3.3 times greater than KDP crystal.« less

  9. 21 CFR 872.1720 - Pulp tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DENTAL DEVICES Diagnostic Devices § 872.1720 Pulp tester. (a) Identification. A pulp tester is an AC or... current transmitted by an electrode to stimulate the nerve tissue in the dental pulp. (b) Classification...

  10. 21 CFR 872.1720 - Pulp tester.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DENTAL DEVICES Diagnostic Devices § 872.1720 Pulp tester. (a) Identification. A pulp tester is an AC or... current transmitted by an electrode to stimulate the nerve tissue in the dental pulp. (b) Classification...

  11. Preliminary evaluation of adhesion strength measurement devices for ceramic/titanium matrix composite bonds

    NASA Technical Reports Server (NTRS)

    Pohlchuck, Bobby; Zeller, Mary V.

    1992-01-01

    The adhesive bond between ceramic cement and a titanium matrix composite substrate to be used in the National Aerospace Plane program is evaluated. Two commercially available adhesion testers, the Sebastian Adherence Tester and the CSEM REVETEST Scratch Tester, are evaluated to determine their suitability for quantitatively measuring adhesion strength. Various thicknesses of cements are applied to several substrates, and bond strengths are determined with both testers. The Sabastian Adherence Tester has provided limited data due to an interference from the sample mounting procedure, and has been shown to be incapable of distinguishing adhesion strength from tensile and shear properties of the cement itself. The data from the scratch tester has been found to be difficult to interpret due to the porosity and hardness of the cement. Recommendations are proposed for a more reliable adhesion test method.

  12. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Court, L; Wang, H; Aten, D

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral andmore » vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.« less

  13. Predicting outcome of Morris water maze test in vascular dementia mouse model with deep learning

    PubMed Central

    Mogi, Masaki; Iwanami, Jun; Min, Li-Juan; Bai, Hui-Yu; Shan, Bao-Shuai; Kukida, Masayoshi; Kan-no, Harumi; Ikeda, Shuntaro; Higaki, Jitsuo; Horiuchi, Masatsugu

    2018-01-01

    The Morris water maze test (MWM) is one of the most popular and established behavioral tests to evaluate rodents’ spatial learning ability. The conventional training period is around 5 days, but there is no clear evidence or guidelines about the appropriate duration. In many cases, the final outcome of the MWM seems predicable from previous data and their trend. So, we assumed that if we can predict the final result with high accuracy, the experimental period could be shortened and the burden on testers reduced. An artificial neural network (ANN) is a useful modeling method for datasets that enables us to obtain an accurate mathematical model. Therefore, we constructed an ANN system to estimate the final outcome in MWM from the previously obtained 4 days of data in both normal mice and vascular dementia model mice. Ten-week-old male C57B1/6 mice (wild type, WT) were subjected to bilateral common carotid artery stenosis (WT-BCAS) or sham-operation (WT-sham). At 6 weeks after surgery, we evaluated their cognitive function with MWM. Mean escape latency was significantly longer in WT-BCAS than in WT-sham. All data were collected and used as training data and test data for the ANN system. We defined a multiple layer perceptron (MLP) as a prediction model using an open source framework for deep learning, Chainer. After a certain number of updates, we compared the predicted values and actual measured values with test data. A significant correlation coefficient was derived form the updated ANN model in both WT-sham and WT-BCAS. Next, we analyzed the predictive capability of human testers with the same datasets. There was no significant difference in the prediction accuracy between human testers and ANN models in both WT-sham and WT-BCAS. In conclusion, deep learning method with ANN could predict the final outcome in MWM from 4 days of data with high predictive accuracy in a vascular dementia model. PMID:29415035

  14. Predicting outcome of Morris water maze test in vascular dementia mouse model with deep learning.

    PubMed

    Higaki, Akinori; Mogi, Masaki; Iwanami, Jun; Min, Li-Juan; Bai, Hui-Yu; Shan, Bao-Shuai; Kukida, Masayoshi; Kan-No, Harumi; Ikeda, Shuntaro; Higaki, Jitsuo; Horiuchi, Masatsugu

    2018-01-01

    The Morris water maze test (MWM) is one of the most popular and established behavioral tests to evaluate rodents' spatial learning ability. The conventional training period is around 5 days, but there is no clear evidence or guidelines about the appropriate duration. In many cases, the final outcome of the MWM seems predicable from previous data and their trend. So, we assumed that if we can predict the final result with high accuracy, the experimental period could be shortened and the burden on testers reduced. An artificial neural network (ANN) is a useful modeling method for datasets that enables us to obtain an accurate mathematical model. Therefore, we constructed an ANN system to estimate the final outcome in MWM from the previously obtained 4 days of data in both normal mice and vascular dementia model mice. Ten-week-old male C57B1/6 mice (wild type, WT) were subjected to bilateral common carotid artery stenosis (WT-BCAS) or sham-operation (WT-sham). At 6 weeks after surgery, we evaluated their cognitive function with MWM. Mean escape latency was significantly longer in WT-BCAS than in WT-sham. All data were collected and used as training data and test data for the ANN system. We defined a multiple layer perceptron (MLP) as a prediction model using an open source framework for deep learning, Chainer. After a certain number of updates, we compared the predicted values and actual measured values with test data. A significant correlation coefficient was derived form the updated ANN model in both WT-sham and WT-BCAS. Next, we analyzed the predictive capability of human testers with the same datasets. There was no significant difference in the prediction accuracy between human testers and ANN models in both WT-sham and WT-BCAS. In conclusion, deep learning method with ANN could predict the final outcome in MWM from 4 days of data with high predictive accuracy in a vascular dementia model.

  15. Operating manual for the miniservo-control tester

    USGS Publications Warehouse

    Rapp, W.L.

    1986-01-01

    Ever since the implementation of servo-control units (regular and minimodels) with manometers at U. S. Geological Survey streamflow stations, the need for an effective and efficient servo-control unit tester has been paramount among field personnel. In numerous cases, servo-control unit failures were blamed on battery failures and vice versa. There was no valid instrument to definitively identify cause of failure, let alone properly diagnose the servo-control/manometer system. In 1983, two servo-control unit testers were developed and fabricated. One was mechanical in fabrication, operation, and serviceability; the other was electronic. The testers were extensively used and evaluated in Maine, Ohio, Kansas, and Louisiana under a wide range of environmental conditions. The consensus to integrate the best aspects of both testers into one instrument allowed the Survey to finally solve its long-time need for an effective, efficient servo-control unit tester. (USGS)

  16. STS-70 mission highlights

    NASA Astrophysics Data System (ADS)

    1995-09-01

    The highlights of the STS-70 mission are presented in this video. The flight crew consisted of Cmdr. John Hendricks, Pilot Kevin Kregel, Flight Engineer Nancy Curie, and Mission Specialists Dr. Don Thomas and Dr. Mary Ellen Weber. The mission's primary objective was the deployment of the 7th Tracking Data and Relay Satellite (TDRS), which will provide a communication, tracking, telemetry, data acquisition, and command services space-based network system essential to low Earth orbital spacecraft. Secondary mission objectives included activating and studying the Physiological and Anatomical Rodent Experiment/National Institutes of Health-Rodents (PARE/NIH-R), The Bioreactor Demonstration System (BDS), the Commercial Protein Crystal Growth (CPCG) studies, the Space Tissue Loss/National Institutes of Health-Cells (STL/NIH-C) experiment, the Biological Research in Canisters (BRIC) experiment, Shuttle Amateur Radio Experiment-2 (SAREX-2), the Visual Function Tester-4 (VFT-4), the Hand-Held, Earth Oriented, Real-Time, Cooperative, User-Friendly, Location-Targeting and Environmental System (HERCULES), the Microcapsules in Space-B (MIS-B) experiment, the Windows Experiment (WINDEX), the Radiation Monitoring Equipment-3 (RME-3), and the Military Applications of Ship Tracks (MAST) experiment. There was an in-orbit dedication ceremony by the spacecrew and the newly Integrated Mission Control Center to commemorate the Center's integration. The STS-70 mission was the first mission monitored by this new control center. Earth views included the Earth's atmosphere, a sunrise over the Earth's horizon, several views of various land masses, some B/W lightning shots, some cloud cover, and a tropical storm.

  17. Biocompatible polyurethane/thiacalix[4]arenes functionalized Fe3O4 magnetic nanocomposites: Synthesis and properties.

    PubMed

    Mohammadi, Abbas; Barikani, Mehdi; Lakouraj, Moslem Mansour

    2016-09-01

    In this study, a series of magnetic polyurethane/Fe3O4 elastomer nanocomposites were prepared by covalently embedding novel thiacalix[4]arenes (TC4As) functionalized Fe3O4 nanoparticles (TC4As-Fe3O4) which contain macrocycles with reactive hydroxyl groups. Surface functionalization of Fe3O4 nanoparticles with TC4As macrocycles as unique reactive surface modifier not only gives specific characteristics to Fe3O4 nanoparticles but also improves the interphase interaction between nanoparticles and the polyurethane matrices through covalent attachment of polymer chains to nanoparticle surfaces. The novel synthesized TC4As-Fe3O4 nanoparticles were characterized by FTIR, XRD, TGA, VSM and SEM analysis. Furthermore, the effect of functionalization of Fe3O4 nanoparticles on the various properties of resulting nanocomposites was studied by XRD, TGA, DMTA, SEM, and a universal tensile tester. It was found that the functionalization of nanoparticles with TC4As affords better mechanical and thermal properties to polyurethane nanocomposites in comparison with unmodified nanoparticles. The SEM analysis showed finer dispersion of TC4As-Fe3O4 nanoparticles than unmodified Fe3O4 nanoparticles within the polyurethane matrices, which arising from formation of covalent bonding between TC4As functionalized Fe3O4 nanoparticles and polyurethane matrices. Moreover, the investigation of in vitro biocompatibility of novel nanocomposites showed that these samples are excellent candidate for biomedical use. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Prevalence of Amblyopia and Refractive Errors Among Primary School Children

    PubMed Central

    Rajavi, Zhale; Sabbaghi, Hamideh; Baghini, Ahmad Shojaei; Yaseri, Mehdi; Moein, Hamidreza; Akbarian, Shadi; Behradfar, Narges; Hosseini, Simin; Rabei, Hossein Mohammad; Sheibani, Kourosh

    2015-01-01

    Purpose: To determine the prevalence of amblyopia and refractive errors among 7 to 12-year-old primary school children in Tehran, Iran. Methods: This population-based cross-sectional study included 2,410 randomly selected students. Visual acuity was tested using an E-chart on Yang vision tester. Refractive errors were measured by photorefractometry and cycloautorefraction. Strabismus was checked using cover test. Direct ophthalmoscopy was used to assess the anterior segment, lens opacities, red reflex and fundus. Functional amblyopia was defined as best corrected visual acuity ≤20/40 in one or both eyes with no anatomical problems. Results: Amblyopia was present in 2.3% (95% CI: 1.8% to 2.9%) of participants with no difference between the genders. Amblyopic subjects were significantly younger than non-amblyopic children (P=0.004). Overall, 15.9% of hyperopic and 5.9% of myopic cases had amblyopia. The prevalence of hyperopia ≥+2.00D, myopia ≤-0.50D, astigmatism ≥0.75D, and anisometropia (≥1.00D) was 3.5%, 4.9%, 22.6%, and 3.9%, respectively. With increasing age, the prevalence of myopia increased (P<0.001), that of hyperopia decreased (P=0.007), but astigmatism showed no change. Strabismus was found in 2.3% of cases. Strabismus (OR=17.9) and refractive errors, especially anisometropia (OR=12.87) and hyperopia (OR=11.87), were important amblyogenic risk factors. Conclusion: The high prevalence of amblyopia in our subjects in comparison to developed countries reveals the necessity of timely and sensitive screening methods. Due to the high prevalence of amblyopia among children with refractive errors, particularly high hyperopia and anisometropia, provision of glasses should be specifically attended by parents and supported by the Ministry of Health and insurance organizations. PMID:27051485

  19. 77 FR 30555 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-23

    ..., oscilloscopes, vibration analysis machines, insulation testers (meggers), and cable fault detectors (impulse... temperature probes; infrared temperature devices and recorders; insulation testers (meggers); voltage, current..., vibration analysis machines, insulation testers (meggers), and cable fault detectors (impulse generators and...

  20. Toward a Unified Theory of Visual Area V4

    PubMed Central

    Roe, Anna W.; Chelazzi, Leonardo; Connor, Charles E.; Conway, Bevil R.; Fujita, Ichiro; Gallant, Jack L.; Lu, Haidong; Vanduffel, Wim

    2016-01-01

    Visual area V4 is a midtier cortical area in the ventral visual pathway. It is crucial for visual object recognition and has been a focus of many studies on visual attention. However, there is no unifying view of V4’s role in visual processing. Neither is there an understanding of how its role in feature processing interfaces with its role in visual attention. This review captures our current knowledge of V4, largely derived from electrophysiological and imaging studies in the macaque monkey. Based on recent discovery of functionally specific domains in V4, we propose that the unifying function of V4 circuitry is to enable selective extraction of specific functional domain-based networks, whether it be by bottom-up specification of object features or by top-down attentionally driven selection. PMID:22500626

  1. Poppet valve tester

    NASA Technical Reports Server (NTRS)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  2. 49 CFR Appendix F to Part 240 - Medical Standards Guidelines

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... greater guidance on the procedures that should be employed in administering the vision and hearing... more errors on plates 1-15. MULTIFUNCTION VISION TESTER Keystone Orthoscope Any error. OPTEC 2000 Any error. Titmus Vision Tester Any error. Titmus II Vision Tester Any error. (3) In administering any of...

  3. 49 CFR Appendix F to Part 240 - Medical Standards Guidelines

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... greater guidance on the procedures that should be employed in administering the vision and hearing... more errors on plates 1-15. MULTIFUNCTION VISION TESTER Keystone Orthoscope Any error. OPTEC 2000 Any error. Titmus Vision Tester Any error. Titmus II Vision Tester Any error. (3) In administering any of...

  4. A reliability study of the new sensors for movement analysis (SHARIF-HMIS).

    PubMed

    Abedi, Mohen; Manshadi, Farideh Dehghan; Zavieh, Minoo Khalkhali; Ashouri, Sajad; Azimi, Hadi; Parnanpour, Mohamad

    2016-04-01

    SHARIF-HMIS is a new inertial sensor designed for movement analysis. The aim of the present study was to assess the inter-tester and intra-tester reliability of some kinematic parameters in different lumbar motions making use of this sensor. 24 healthy persons and 28 patients with low back pain participated in the current reliability study. The test was performed in five different lumbar motions consisting of lumbar flexion in 0, 15, and 30° in the right and left directions. For measuring inter-tester reliability, all the tests were carried out twice on the same day separately by two physiotherapists. Intra-tester reliability was assessed by reproducing the tests after 3 days by the same physiotherapist. The present study revealed satisfactory inter- and intra-tester reliability indices in different positions. ICCs for intra-tester reliability ranged from 0.65 to 0.98 and 0.59 to 0.81 for healthy and patient participants, respectively. Also, ICCs for inter-tester reliability ranged from 0.65 to 0.92 for the healthy and 0.65 to 0.87 for patient participants. In general, it can be inferred from the results that measuring the kinematic parameters in lumbar movements using inertial sensors enjoys acceptable reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Activation and inactivation of carcinogenic dihaloalkanes and other compounds by glutathione S-transferase 5-5 in Salmonella typhimurium tester strain NM5004.

    PubMed

    Shimada, T; Yamazaki, H; Oda, Y; Hiratsuka, A; Watabe, T; Guengerich, F P

    1996-01-01

    A newly developed tester Salmonella typhimurium NM5004 strain was constructed by introducing a plasmid containing both rat GSH S-transferase (GST) 5-5 cDNA and the umuC"lacZ operon into the host strain Salmonella typhimurium TA1535 and used to examine whether or not GST modified the genotoxic activities of several dihaloalkanes and other compounds. Twenty-nine chemicals that were suggested to be conjugated by GST were compared with regard to their abilities to induce umu gene expression and cause cytotoxicity responses in both the NM5004 strain and the original tester strain (S. typhimurium TA1535/pSK1002, which is devoid of GST activity toward 1,2-epoxy-3-(4'-nitrophenoxy)propane). Ten chemicals--1,2-dibromoethane,N-(2,3-epoxypropyl)phthalimide, 1,3-dichloroacetone, CH2I2, 1,2-epoxy-3-phenoxypropane, 2,3-epoxypropyl p-methoxyphenyl ether, 1-bromo-2-chloroethane, 1-bromo-2,3-dichloropropane, CH2BrCl, and CH2Br2--were found to enhance induction of umu gene expression in the NM5004 strain as compared with the TA1535/pSK1002 strain. 1,2-Epoxy-3-(4'-nitrophenoxy)propane and 2,3-dibromo-1-chloropropane were inactivated by GST 5-5 in the NM5004 tester strain, although these chemicals were cytotoxic in both tester strains. Roles of GST 5-5 were also examined for the inactivation of reactive metabolites of several procarcinogens that were formed through oxidation by liver microsomes of polychlorinated biphenyl-treated rats. The results suggest that reactive metabolites (possibly epoxides) of aflatoxin B1, sterigmatocystin, 1,2-dihydro-1,2-dihydroxy-6-aminochrysene, and (+)- and (-)-enantiomers of 7,8-dihydroxy-7,8-dihydrobenzo[a]pyrene could be trapped as inactivated GSH conjugates in the NM5004 strain. High-performance liquid chromatographic analysis suggested that exo-aflatoxin B1-8,9-oxide--GSH conjugate was formed during the oxidation of aflatoxin B1 by rat and human liver microsomes in the presence of GSH and several GST enzymes including purified rat theta class GST Yrs-Yrs and rat liver GST (a mixture of alpha and mu class enzymes). Thus, the present results support the view that the theta class rat GST 5-5 enzyme participates in the activation and inactivation of potential environmental carcinogenic chemicals. This newly developed NM5004 tester strain is of use in the elucidation of roles of GST 5-5 in transformations.

  6. Using Peer-Referral Chains with Incentives to Promote HIV Testing and Identify Undiagnosed HIV Infections Among Crack Users in San Salvador

    PubMed Central

    Glasman, Laura R.; Dickson-Gomez, Julia; Lechuga, Julia; Tarima, Sergey; Bodnar, Gloria; de Mendoza, Lorena Rivas

    2016-01-01

    In El Salvador, crack users are at high risk for HIV but they are not targeted by efforts to promote early HIV diagnosis. We evaluated the promise of peer-referral chains with incentives to increase HIV testing and identify undiagnosed HIV infections among networks of crack users in San Salvador. For 14 months, we offered HIV testing in communities with a high prevalence of crack use. For the following 14 months, we promoted chains in which crack users from these communities referred their peers to HIV testing and received a small monetary incentive. We recorded the monthly numbers of HIV testers, and their crack use, sexual risk behaviors and test results. After launching the referral chains, the monthly numbers of HIV testers increased significantly (Z = 6.90, p < .001) and decayed more slowly (Z = 5.93, p < .001), and the total number of crack-using testers increased nearly fourfold. Testers in the peer-referral period reported fewer HIV risk behaviors, but a similar percentage (~5 %) tested HIV positive in both periods. More women than men received an HIV-positive diagnosis throughout the study (χ2(1, N = 799) = 4.23, p = .040). Peer-referral chains with incentives can potentially increase HIV testing among networks of crack users while retaining a focus on high-risk individuals. PMID:26687093

  7. All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki

    2009-03-01

    To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P

  8. Final visual acuity results in the early treatment for retinopathy of prematurity study.

    PubMed

    Good, William V; Hardy, Robert J; Dobson, Velma; Palmer, Earl A; Phelps, Dale L; Tung, Betty; Redford, Maryann

    2010-06-01

    To compare visual acuity at 6 years of age in eyes that received early treatment for high-risk prethreshold retinopathy of prematurity (ROP) with conventionally managed eyes. Infants with symmetrical, high-risk prethreshold ROP (n = 317) had one eye randomized to earlier treatment at high-risk prethreshold disease and the other eye managed conventionally, treated if ROP progressed to threshold severity. For asymmetric cases (n = 84), the high-risk prethreshold eye was randomized to either early treatment or conventional management. The main outcome measure was ETDRS visual acuity measured at 6 years of age by masked testers. Retinal structure was assessed as a secondary outcome. Analysis of all subjects with high-risk prethreshold ROP showed no statistically significant benefit for early treatment (24.3% vs 28.6% [corrected] unfavorable outcome; P = .15). Analysis of 6-year visual acuity results according to the Type 1 and 2 clinical algorithm showed a benefit for Type 1 eyes (25.1% vs 32.8%; P = .02) treated early but not Type 2 eyes (23.6% vs 19.4%; P = .37). Early-treated eyes showed a significantly better structural outcome compared with conventionally managed eyes (8.9% vs 15.2% unfavorable outcome; P < .001), with no greater risk of ocular complications. Early treatment for Type 1 high-risk prethreshold eyes improved visual acuity outcomes at 6 years of age. Early treatment for Type 2 high-risk prethreshold eyes did not. Application to Clinical Practice Type 1 eyes, not Type 2 eyes, should be treated early. These results are particularly important considering that 52% of Type 2 high-risk prethreshold eyes underwent regression of ROP without requiring treatment. Trial Registration clinicaltrials.gov Identifier: NCT00027222.

  9. 21 CFR 872.1730 - Electrode gel for pulp testers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrode gel for pulp testers. 872.1730 Section 872.1730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1730 Electrode gel for pulp testers. (a...

  10. 21 CFR 872.1730 - Electrode gel for pulp testers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electrode gel for pulp testers. 872.1730 Section 872.1730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1730 Electrode gel for pulp testers. (a...

  11. Functional and nonfunctional testing of ATM networks

    NASA Astrophysics Data System (ADS)

    Ricardo, Manuel; Ferreira, M. E. P.; Guimaraes, Francisco E.; Mamede, J.; Henriques, M.; da Silva, Jorge A.; Carrapatoso, E.

    1995-02-01

    ATM network will support new multimedia services that will require new protocols, those services and protocols will need different test strategies and tools. In this paper, the concepts of functional and non-functional testers of ATM networks are discussed, a multimedia service and its requirements are presented and finally, a summary description of an ATM network and of the test tool that will be used to validate it are presented.

  12. Cable Tester Box

    NASA Technical Reports Server (NTRS)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  13. Defibrillator synchronization tester.

    PubMed

    Demirbilek, Fatma N; Krajnak, Mike; Stolarczyk, George

    2009-01-01

    A defibrillator sync output signal connector provides an ECG synchronization signal that can be used by some defibrillators for the purpose of performing synchronized cardioversion [1]. This process is used to stop an abnormally fast heart rate or cardiac arrhythmia by the delivery of a therapeutic dose of electric current to the heart during the R-wave of the cardiac cycle. Timing the shock to the R-wave prevents the delivery of the shock during the vulnerable period of the cardiac cycle, which could induce ventricular fibrillation [2]. GE patient monitors include a selectable analog output feature, which provides an analog ECG or arterial blood pressure signal. The blood pressure signal can be used to synchronize balloon pumps to provide cardiac assist to post-MI patients with poor injection fraction. Proper operation requires the defibrillator sync and analog output function to be checked. Checkouts are typically done during planned maintenance and after major part replacements such as patient monitor's main CPU board. Checking out defibrillator sync signals could be done using a GE defibrillator sync tester. The defibrillator sync tester provides a loop back path for the defibrillator sync signals to be displayed on the patient monitor screen and eliminates the need for an external oscilloscope.

  14. Characterization by Suppression Subtractive Hybridization of Transcripts That Are Differentially Expressed in Leaves of Anthracnose-Resistant Ramie Cultivar.

    PubMed

    Xuxia, Wang; Jie, Chen; Bo, Wang; Lijun, Liu; Hui, Jiang; Diluo, Tang; Dingxiang, Peng

    2012-01-01

    For the purpose of screening putative anthracnose resistance-related genes of ramie ( Boehmeria nivea L. Gaud), a cDNA library was constructed by suppression subtractive hybridization using anthracnose-resistant cultivar Huazhu no. 4. The cDNAs from Huazhu no. 4, which were infected with Colletotrichum gloeosporioides , were used as the tester and cDNAs from uninfected Huazhu no. 4 as the driver. Sequencing analysis and homology searching showed that these clones represented 132 single genes, which were assigned to functional categories, including 14 putative cellular functions, according to categories established for Arabidopsis . These 132 genes included 35 disease resistance and stress tolerance-related genes including putative heat-shock protein 90, metallothionein, PR-1.2 protein, catalase gene, WRKY family genes, and proteinase inhibitor-like protein. Partial disease-related genes were further analyzed by reverse transcription PCR and RNA gel blot. These expressed sequence tags are the first anthracnose resistance-related expressed sequence tags reported in ramie.

  15. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength.

    PubMed

    Thorborg, K; Bandholm, T; Schick, M; Jensen, J; Hölmich, P

    2013-08-01

    Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P < 0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  17. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  18. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  19. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  20. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  1. General Purpose Vehicle Mechanic Career Ladder, AFSCs 47232, 47252, and 47275.

    DTIC Science & Technology

    1983-03-01

    general-purpose vehicles; gasoline and diesel engines; automotive electrical and emission control systems maintenance; drive trains and brake systems...OR HYDRAULIC PRESSES ELECTRONIC IGNITION TESTERS HEADLIGHT TESTERS OSCILLOSCOPES DYNAMOMETERS EXHAUST EMISSION TESTERS GAS SHIELD WELDING...collection forms; man-hour accounting forms and reports; corrosion control procedures; troubleshooting exhaust systems, and emission control systems

  2. STS-70 Space Shuttle Mission Report - September 1995

    NASA Technical Reports Server (NTRS)

    Fricke, Robert W., Jr.

    1995-01-01

    The STS-70 Space Shuttle Program Mission Report summarizes the Payload activities as well as the Orbiter, External Tank (ET), Solid Rocket Booster (SRB), Reusable Solid Rocket Motor (RSRM), and the Space Shuttle main engine (SSME) systems performance during the seventieth flight of the Space Shuttle Program, the forty-fifth flight since the return-to-flight, and the twenty-first flight of the Orbiter Discovery (OV-103). In addition to the Orbiter, the flight vehicle consisted of an ET that was designated ET-71; three SSMEs that were designated as serial numbers 2036, 2019, and 2017 in positions 1, 2, and 3, respectively; and two SRBs that were designated 81-073. The RSRMs, designated RSRM-44, were installed in each SRB and were designated as 36OL044A for the left SRB, and 36OL044B for the right SRB. The primary objective of this flight was to deploy the Tracking and Data Relay Satellite-G/Inertial Upper Stage (TDRS-G/IUS). The secondary objectives were to fulfill the requirements of the Physiological and Anatomical Rodent Experiment/National Institutes of Health-Rodents (PARE/NIH-R); Bioreactor Demonstration System (BDS); Commercial Protein Crystal Growth (CPCG) experiment; Space Tissue Loss/National Institutes of Health - Cells (STL/NIH-C) experiment; Biological Research in Canisters (BRIC) experiment; Shuttle Amateur Radio Experiment-2 (SAREX-2); Visual Function Tester-4 (VFT-4); Hand-Held, Earth-Oriented, Real-Time, Cooperative, User-Friendly Location-Targeting and Environmental System (HERCULES); Microencapsulation in Space-B (MIS-B) experiment; Window Experiment (WINDEX); Radiation Monitoring Equipment-3 (RME-3); and the Military Applications of Ship Tracks (MAST) payload.

  3. A Cheap, Semiquantitative Hand-Held Conductivity Tester.

    ERIC Educational Resources Information Center

    Zawacky, Susan K. S.

    1995-01-01

    Describes a design for a hand-held conductivity tester powered by a 9V battery that gives semi-quantitative results for aqueous electrolyte solutions of concentrations ranging from 0.001 M to 0.1 M. The tester uses a bar-graph LED driven by an LM3914 integrated circuit to indicate the level of conductivity. A list of parts, procedures, and results…

  4. Evaluation of the Hamburg Rut Tester and Moisture Induced Stress Test (MIST) for field control of hot mix asphalt (HMA) in Oklahoma : final report.

    DOT National Transportation Integrated Search

    2013-03-01

    This report covers the evaluation of the Hamburg Loaded Wheel Rut Tester (OHD L-55) and the : Moisture Induced Stress Tester (MIST) for field control of Oklahoma HMA mixtures. OHD L-55 : was evaluated as a possible replacement for AASHTO T 283 and fo...

  5. Development of a tester for evaluation of prototype thermal cells and batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guidotti, R.A.

    1994-10-01

    A tester was developed to evaluate prototype thermal cells and batteries--especially high-voltage units--under a wide range of constant-current and constant-resistance discharge conditions. Programming of the steady-state and pulsing conditions was by software control or by hardware control via an external pulse generator. The tester was assembled from primarily Hewlett-Packard (H-P) instrumentation and was operated under H-P`s Rocky Mountain Basic (RMB). Constant-current electronic loads rated up to 4 kW (400 V at up to 100 A) were successfully used with the setup. For testing under constant-resistance conditions, power metal-oxide field-effect transistors (MOSFETs) controlled by a programmable pulse generator were used tomore » switch between steady-state and pulse loads. The pulses were digitized at up to a 50 kHz rate (20 {mu} s/pt) using high-speed DVMs; steady-state voltages were monitored with standard DVMs. This paper describes several of the test configurations used and discusses the limitations of each. Representative data are presented for a number of the test conditions.« less

  6. USAF bioenvironmental noise data handbook. Volume 166: AF/M32T-1 tester, pressurized cabin leakage, aircraft

    NASA Astrophysics Data System (ADS)

    Rau, T. H.

    1982-07-01

    Measured and extrapolated data define the bioacoustic environments produced by a gasoline engine driven cabin leakage tester operating outdoors on a concrete apron at normal rated conditions. Near field data are presented for 37 locations at a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.

  7. Implementation Considerations for Multisite Clinical Trials with Cognitive Neuroscience Tasks

    PubMed Central

    Keefe, Richard S. E.; Harvey, Philip D.

    2008-01-01

    Multisite clinical trials aimed at cognitive enhancement across various neuropsychiatric conditions have employed standard neuropsychological tests as outcome measures. While these tests have enjoyed wide clinical use and have proven reliable and predictive of functional disability, a number of implementation challenges have arisen when these tests are used in clinical trials. These issues are likely to be magnified in future studies when cognitive neuroscience (CN) procedures are explored in these trials, because in their current forms CN procedures are less standardized and more difficult to teach and monitor. For multisite trials, we anticipate that the most challenging issues will include assuring tester competence, monitoring tester performance, specific challenges with complex assessment methods, and having resources available for adequate monitoring of data quality. Suggestions for overcoming these implementation challenges are offered. PMID:18495645

  8. Microprocessor tester for the treat upgrade reactor trip system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenkszus, F.R.; Bucher, R.G.

    1984-01-01

    The upgrading of the Transient Reactor Test (TREAT) Facility at ANL-Idaho has been designed to provide additional experimental capabilities for the study of core disruptive accident (CDA) phenomena. In addition, a programmable Automated Reactor Control System (ARCS) will permit high-power transients up to 11,000 MW having a controlled reactor period of from 15 to 0.1 sec. These modifications to the core neutronics will improve simulation of LMFBR accident conditions. Finally, a sophisticated, multiply-redundant safety system, the Reactor Trip System (RTS), will provide safe operation for both steady state and transient production operating modes. To insure that this complex safety systemmore » is functioning properly, a Dedicated Microprocessor Tester (DMT) has been implemented to perform a thorough checkout of the RTS prior to all TREAT operations.« less

  9. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  10. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  11. 38 CFR 4.75 - General considerations for evaluating visual impairment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... refraction), visual field, and muscle function. (b) Examination for visual impairment. The examination must.... Examinations of visual fields or muscle function will be conducted only when there is a medical indication of disease or injury that may be associated with visual field defect or impaired muscle function. Unless...

  12. Evaluation of disintegration properties of orally rapidly disintegrating tablets using a novel disintegration tester.

    PubMed

    Kondo, Keita; Niwa, Toshiyuki; Danjo, Kazumi

    2012-01-01

    This report describes a new disintegration tester that can determine not only the disintegration time of orally rapidly disintegrating tablets (ODT), but also the disintegration behavior and mechanism. Using the tester, the disintegration properties of the tablets prepared in a previous study were examined. The purpose of this study is to confirm the utility of the tester as an instrument for evaluating the disintegration properties of ODT and determine relations among time, behavior and mechanism of the disintegration. Results demonstrated that in vitro disintegration time in the tester is similar to that in the commercial disintegration tester for ODT and is highly correlated with oral disintegration time. Observations of disintegration process revealed that a difference in disintegration behavior between tablets compressed at 50-75 MPa and 100 MPa; the disintegration behavior of the tablets were designated immediate disintegrating type and gradual disintegrating type, respectively. The dynamic swelling profile and water absorption profile indicated that the disintegration mechanism of the tablets involved wicking action induced by swelling of the disintegrant; the disintegration time was closely related to the initial rates of swelling and water absorption. Furthermore, the mechanism of water absorption of tablets compressed at 50-75 MPa and 100 MPa shows anomalous diffusion and case-II transport, respectively. The shift in this mechanism is consistent with differences in disintegration time and behavior between the tablets. These findings suggest that information on disintegration properties obtained by our tester is useful for understanding of disintegration phenomena of ODT.

  13. Using Peer-Referral Chains with Incentives to Promote HIV Testing and Identify Undiagnosed HIV Infections Among Crack Users in San Salvador.

    PubMed

    Glasman, Laura R; Dickson-Gomez, Julia; Lechuga, Julia; Tarima, Sergey; Bodnar, Gloria; de Mendoza, Lorena Rivas

    2016-06-01

    In El Salvador, crack users are at high risk for HIV but they are not targeted by efforts to promote early HIV diagnosis. We evaluated the promise of peer-referral chains with incentives to increase HIV testing and identify undiagnosed HIV infections among networks of crack users in San Salvador. For 14 months, we offered HIV testing in communities with a high prevalence of crack use. For the following 14 months, we promoted chains in which crack users from these communities referred their peers to HIV testing and received a small monetary incentive. We recorded the monthly numbers of HIV testers, and their crack use, sexual risk behaviors and test results. After launching the referral chains, the monthly numbers of HIV testers increased significantly (Z = 6.90, p < .001) and decayed more slowly (Z = 5.93, p < .001), and the total number of crack-using testers increased nearly fourfold. Testers in the peer-referral period reported fewer HIV risk behaviors, but a similar percentage (~5 %) tested HIV positive in both periods. More women than men received an HIV-positive diagnosis throughout the study (χ(2)(1, N = 799) = 4.23, p = .040). Peer-referral chains with incentives can potentially increase HIV testing among networks of crack users while retaining a focus on high-risk individuals.

  14. Hand-Drawn Resistors and a Simple Tester Using a Light-Emitting Diode

    ERIC Educational Resources Information Center

    Kamata, Masahiro; Abe, Mayumi

    2012-01-01

    A thick line drawn on a sheet of paper with a 6B pencil is electrically conductive and its resistance can be roughly estimated using a simple tester made of a light-emitting diode (LED) and a lithium coin-type cell. Using this hand-drawn resistor and the LED tester, we developed teaching materials that help students to understand how electrical…

  15. Visual acuity at 10 years in Cryotherapy for Retinopathy of Prematurity (CRYO-ROP) study eyes: effect of retinal residua of retinopathy of prematurity.

    PubMed

    Dobson, Velma; Quinn, Graham E; Summers, C Gail; Hardy, Robert J; Tung, Betty

    2006-02-01

    To describe recognition (letter) acuity at age 10 years in eyes with and without retinal residua of retinopathy of prematurity (ROP). Presence and severity of ROP residua were documented by a study ophthalmologist. Masked testers measured monocular recognition visual acuity (Early Treatment of Diabetic Retinopathy Study) when the children were 10 years old. Two hundred forty-seven of 255 surviving Cryotherapy for Retinopathy of Prematurity (CRYO-ROP) randomized trial patients participated. A reference group of 102 of 104 Philadelphia-based CRYO-ROP study participants who did not develop ROP was also tested. More severe retinal residua were associated with worse visual acuity, regardless of whether retinal ablation was performed to treat the severe acute-phase ROP. However, within each ROP residua category, there was a wide range of visual acuity results. This is the first report of the relation between visual acuity (Early Treatment of Diabetic Retinopathy Study charts) and structural abnormalities related to ROP in a large group of eyes that developed threshold ROP in the perinatal period. Visual deficits are greater in eyes with more severe retinal residua than in eyes with mild or no residua. However, severity of ROP residua does not predict the visual acuity of an individual eye because within a single residua category, acuity may range from near normal to blind.

  16. Efficient clinical evaluation of guideline quality: development and testing of a new tool

    PubMed Central

    2014-01-01

    Background Evaluating the methodological quality of clinical practice guidelines is essential before deciding which ones which could best inform policy or practice. One current method of evaluating clinical guideline quality is the research-focused AGREE II instrument. This uses 23 questions scored 1–7, arranged in six domains, which requires at least two independent testers, and uses a formulaic weighted domain scoring system. Following feedback from time-poor clinicians, policy-makers and managers that this instrument did not suit clinical need, we developed and tested a simpler, shorter, binary scored instrument (the iCAHE Guideline Quality Checklist) designed for single users. Methods Content and construct validity, inter-tester reliability and clinical utility were tested by comparing the new iCAHE Guideline Quality Checklist with the AGREE II instrument. Firstly the questions and domains in both instruments were compared. Six randomly-selected guidelines on a similar theme were then assessed by three independent testers with different experience in guideline quality assessment, using both instruments. Per guideline, weighted domain and total AGREE II scores were calculated, using the scoring rubric for three testers. Total iCAHE scores were calculated per guideline, per tester. The linear relationship between iCAHE and AGREE II scores was assessed using Pearson r correlation coefficients. Score differences between testers were assessed for the iCAHE Guideline Quality Checklist. Results There were congruent questions in each instrument in four domains (Scope & Purpose, Stakeholder involvement, Underlying evidence/Rigour, Clarity). The iCAHE and AGREE II scores were moderate to strongly correlated for the six guidelines. There was generally good agreement between testers for iCAHE scores, irrespective of their experience. The iCAHE instrument was preferred by all testers, and took significantly less time to administer than the AGREE II instrument. However, the use of only three testers and six guidelines compromised study power, rendering this research as pilot investigations of the psychometric properties of the iCAHE instrument. Conclusion The iCAHE Guideline Quality Checklist has promising psychometric properties and clinical utility. PMID:24885893

  17. [Are German information materials on colorectal cancer screening understandable or do they fail? Rating of health information by users with different educational backgrounds].

    PubMed

    Seidel, G; Münch, I; Dreier, M; Borutta, B; Walter, U; Dierks, M-L

    2014-03-01

    Evidence-based patient information is an essential part of decision making in health issues. A qualitative study was conducted to examine whether consumers consider the health information on colorectal cancer screening in Germany helpful in supporting their decision making. In this study, eight texts from different German authors about colorectal cancer screening were evaluated with a criteria-based selection. The texts were tested for understandability, structure, design, and effect on readers. Thirteen semi-structured focus groups were formed including 59 higher-educated and 15 lower-educated testers, 46 % of them being male with a mean age of 62.9 years. The transcripts were analyzed by content-analytic assessment. The testers provided detailed comments on the content and design of the texts. They revealed inaccuracies and suggested improvements of the texts. The testers differed from each other in terms of the intensity of their participation in the discussions and comprehension of the material. The reception of the flyers and brochures varied according to the educational level of the testers. Lower-educated testers often skipped passages of texts about risks as well as passages containing numbers and graphics. The texts had different effects on the testers, regardless of the level of education. If adverse effects were presented, some testers became scared while others were reassured because they felt informed. Most of the testers appreciated a call for participation as a central message of the text. Sometimes, if there was no clear appeal to attend the screening, the testers even asked for it. The recently introduced political strategy of promoting an informed choice is applied to an unprepared population who was used to getting a clear yes-or-no recommendation. Thus, at first, the population has to learn how to make an informed choice. This topic must be addressed and taken into account in the process of developing health information. Since this is not always the case, we conclude that current materials are limited in their contribution toward the decision of attending CRC screening.

  18. Common tester platform concept.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurst, Michael James

    This report summarizes the results of a case study on the doctrine of a common tester platform, a concept of a standardized platform that can be applicable across the broad spectrum of testing requirements throughout the various stages of a weapons program, as well as across the various weapons programs. The common tester concept strives to define an affordable, next-generation design that will meet testing requirements with the flexibility to grow and expand; supporting the initial development stages of a weapons program through to the final production and surveillance stages. This report discusses a concept investing key leveraging technologies andmore » operational concepts combined with prototype tester-development experiences and practical lessons learned gleaned from past weapons programs.« less

  19. 49 CFR 393.52 - Brake performance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Brake performance. 393.52 Section 393.52... NECESSARY FOR SAFE OPERATION Brakes § 393.52 Brake performance. (a) Upon application of its service brakes... braking force is measured by a performance-based brake tester which meets the requirements of functional...

  20. 49 CFR 393.52 - Brake performance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Brake performance. 393.52 Section 393.52... NECESSARY FOR SAFE OPERATION Brakes § 393.52 Brake performance. (a) Upon application of its service brakes... braking force is measured by a performance-based brake tester which meets the requirements of functional...

  1. 49 CFR 393.52 - Brake performance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Brake performance. 393.52 Section 393.52... NECESSARY FOR SAFE OPERATION Brakes § 393.52 Brake performance. (a) Upon application of its service brakes... braking force is measured by a performance-based brake tester which meets the requirements of functional...

  2. 49 CFR 393.52 - Brake performance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Brake performance. 393.52 Section 393.52... NECESSARY FOR SAFE OPERATION Brakes § 393.52 Brake performance. (a) Upon application of its service brakes... braking force is measured by a performance-based brake tester which meets the requirements of functional...

  3. 49 CFR 393.52 - Brake performance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Brake performance. 393.52 Section 393.52... NECESSARY FOR SAFE OPERATION Brakes § 393.52 Brake performance. (a) Upon application of its service brakes... braking force is measured by a performance-based brake tester which meets the requirements of functional...

  4. The utility of quantitative electroencephalography and Integrated Visual and Auditory Continuous Performance Test as auxiliary tools for the Attention Deficit Hyperactivity Disorder diagnosis.

    PubMed

    Kim, JunWon; Lee, YoungSik; Han, DougHyun; Min, KyungJoon; Kim, DoHyun; Lee, ChangWon

    2015-03-01

    This study investigated the clinical utility of quantitative electroencephalography (QEEG) and the Integrated Visual and Auditory Continuous Performance Test (IVA+CPT) as auxiliary tools for assessing Attention Deficit Hyperactivity Disorder (ADHD). All of 157 subjects were assessed using the Korean version of the Diagnostic Interview Schedule for Children Version IV (DISC-IV). We measured EGG absolute power in 21 channels and conducted IVA+CPT. We analyzed QEEG according to the Hz range: delta (1-4Hz), theta (4-8Hz), slow alpha (8-10Hz), fast alpha (10-13.5Hz), and beta (13.5-30Hz). To remove artifacts, independent component analysis was conducted (ICA), and the tester confirmed the results again. All of the IVA+CPT quotients showed significant differences between the ADHD and control groups. The ADHD group showed significantly increased delta and theta activity compared with the control group. The z-scores of theta were negatively correlated with the scores of IVA+CPT in ADHD combined type, and those of beta were positively correlated. IVA+CPT and QEEG significantly discriminated between ADHD and control groups. The commission error of IVA+CPT showed an accuracy of 82.1%, and the omission error of IVA+CPT showed an accuracy of 78.6%. The IVA+CPT and QEEG are expected to be valuable tools for aiding ADHD diagnosis accurately. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The Rocketdyne Multifunction Tester. Part 2: Operation of a Radial Magnetic Bearing as an Excitation Source

    NASA Technical Reports Server (NTRS)

    Hawkins, L. A.; Murphy, Brian T.; Lang, K. W.

    1991-01-01

    The operation of the magnetic bearing used as an excitation source in the Rocketdyne Multifunction Tester is described. The tester is scheduled for operation during the summer of 1990. The magnetic bearing can be used in two control modes: (1) open loop mode, in which the magnetic bearing operates as a force actuator; and (2) closed loop mode, in which the magnetic bearing provides shaft support. Either control mode can be used to excite the shaft; however, response of the shaft in the two control modes is different due to the alteration of the eigenvalues by closed loop mode operation. A rotordynamic model is developed to predict the frequency response of the tester due to excitation in either control mode. Closed loop mode excitation is shown to be similar to the excitation produced by a rotating eccentricity in a conventional bearing. Predicted frequency response of the tester in the two control modes is compared, and the maximum response is shown to be the same for the two control modes when synchronous unbalance loading is not considered. The analysis shows that the response of this tester is adequate for the extraction of rotordynamic stiffness, damping, and inertia coefficients over a wide range of test article stiffnesses.

  7. Steering nitrogen fertilisation by means of portable chlorophyll meter reduces nitrogen input and improves quality of fertigated cantaloupe (Cucumis melo L. var. cantalupensis Naud.).

    PubMed

    Gianquinto, Giorgio; Fecondini, Marco; Mezzetti, Mirco; Orsini, Francesco

    2010-02-01

    Farming is considered one of the main causes of land degradation and underground water pollution. The increased availability of agricultural inputs has led to a dramatic rise in yields, which has resulted in soil fertility spoilage and overuse of fertilisers. Therefore horticultural practice improvement must consider appropriate nitrogen (N) management. This paper reports results on the application of an optical diagnostic system (N-tester) to guide N fertilisation in muskmelon (Cucumis melo L.) over a 3 year trial. Results on fresh and postharvest quality are also presented. Fertilisation events mirrored increases in N-tester values during the season, and a significant linear relationship (R(2) = 0.628) was observed between N-tester readings and leaf chlorophyll content. The N-tester-guided fertilisation treatments were characterised by yields comparable to the control, but with significantly lower applications of N (down to 17-66% of the N distributed in the control). Moreover, the N-tester treatments yielded fruits with higher sugar content. This was also true after storage, when N-tester fruits also showed reduced weight loss associated with lower transpiration and ethylene emission rates. Through the use of 'spy plots' kept at optimal nutritional status and the adoption of a threshold for N application throughout the growing cycle of muskmelon, the N supply was significantly reduced. Therefore a correct application of N-tester allowed the plant N requirement to be reduced and the fruit sugar content and storability to be increased without adversely affecting the yield.

  8. Liquid Crystals

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Thermochromic liquid crystals, or TLCs, are a type of liquid crystals that react to changes in temperature by changing color. The Hallcrest/NASA collaboration involved development of a new way to visualize boundary layer transition in flight and in wind tunnel testing of aircraft wing and body surfaces. TLCs offered a new and potentially better method of visualizing the boundary layer transition in flight. Hallcrest provided a liquid crystal formulation technique that afforded great control over the sensitivity of the liquid crystals to varying conditions. Method is of great use to industry, government and universities for aerodynamic and hydrodynamic testing. Company's principal line is temperature indicating devices for industrial use, such as non-destructive testing and flaw detection in electric/electronic systems, medical application, such as diagnostic systems, for retail sale, such as room, refrigerator, baby bath and aquarium thermometers, and for advertising and promotion specials. Additionally, Hallcrest manufactures TLC mixtures for cosmetic applications, and liquid crystal battery tester for Duracell batteries.

  9. Test-retest reliability of myofascial trigger point detection in hip and thigh areas.

    PubMed

    Rozenfeld, E; Finestone, A S; Moran, U; Damri, E; Kalichman, L

    2017-10-01

    Myofascial trigger points (MTrP's) are a primary source of pain in patients with musculoskeletal disorders. Nevertheless, they are frequently underdiagnosed. Reliable MTrP palpation is the necessary for their diagnosis and treatment. The few studies that have looked for intra-tester reliability of MTrPs detection in upper body, provide preliminary evidence that MTrP palpation is reliable. Reliability tests for MTrP palpation on the lower limb have not yet been performed. To evaluate inter- and intra-tester reliability of MTrP recognition in hip and thigh muscles. Reliability study. 21 patients (15 males and 6 females, mean age 21.1 years) referred to the physical therapy clinic, 10 with knee or hip pain and 11 with pain in an upper limb, low back, shin or ankle. Two experienced physical therapists performed the examinations, blinded to the subjects' identity, medical condition and results of the previous MTrP evaluation. Each subject was evaluated four times, twice by each examiner in a random order. Dichotomous findings included a palpable taut band, tenderness, referred pain, and relevance of referred pain to patient's complaint. Based on these, diagnosis of latent MTrP's or active MTrP's was established. The evaluation was performed on both legs and included a total of 16 locations in the following muscles: rectus femoris (proximal), vastus medialis (middle and distal), vastus lateralis (middle and distal) and gluteus medius (anterior, posterior and distal). Inter- and intra-tester reliability (Cohen's kappa (κ)) values for single sites ranged from -0.25 to 0.77. Median intra-tester reliability was 0.45 and 0.46 for latent and active MTrP's, and median inter-tester reliability was 0.51 and 0.64 for latent and active MTrPs, respectively. The examination of the distal vastus medialis was most reliable for latent and active MTrP's (intra-tester k = 0.27-0.77, inter-tester k = 0.77 and intra-tester k = 0.53-0.72, inter-tester k = 0.72, correspondingly). Inter- and intra-tester reliability of active and latent MTrP evaluation was moderate to substantial. Palpation evaluation can be used for clinical diagnosis of MTrP's in the hip and thigh muscles. This study provides evidence that MTrP palpation is a moderately reliable diagnostic tool in the hip and thigh muscles and can be used in clinical practice and research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A Double-Primary Dead-Weight Tester for Pressures (35-175) kPa in Gage Mode.

    PubMed

    Jain, Kamlesh; Cen, Yueqin; Bowers, Walter J; Schmidt, James W

    2003-01-01

    Primary pressure standards in the atmospheric pressure range are often established using mercury manometers. Less frequently, controlled-clearance dead-weight testers in which one component (normally the piston) has been dimensionally measured have also been used. Recent advances in technology on two fronts i) the fabrication of large-diameter pistons and cylinders with good geometry; and ii) the ability to measure the dimensions of these components, have allowed some dead-weight testers at NIST to approach total relative uncertainties (k = 2) in dimensionally-derived effective areas near 5 × 10(-6). This paper describes a single piston/cylinder assembly (NIST-PG201WC/WC) that serves as both a primary gage in which both piston and cylinder are measured dimensionally and a controlled-clearance primary gage (employing the Heydemann-Welch method). Thus it allows some previous assumptions about the modeling of dead-weight testers to be checked. For the gage described in this paper the piston/cylinder clearance obtained from the two analyses have relative differences of 4 × 10(-6) to 7 × 10(-6) over the pressure range 35 kPa to 175 kPa. Some implications of these results will be discussed. From the dimensional characterizations and auxiliary measurements we have determined that the effective area for this gauge at 20 °C is: [Formula: see text]where P is the system pressure and P J is a control pressure. The estimated relative uncertainty in effective area is 8.2 × 10(-6) +1.4 × 10(-11) P/Pa (k = 2). The temperature coefficient for the area was measured and found to be (9.06 ± 0.04) × 10(-6)/K. Thus using the gage at a reference temperature of 23 °C yields an effective area: [Formula: see text]with almost no increase in the uncertainty over that at 20 °C.

  11. MC-TESTER v. 1.23: A universal tool for comparisons of Monte Carlo predictions for particle decays in high energy physics

    NASA Astrophysics Data System (ADS)

    Davidson, N.; Golonka, P.; Przedziński, T.; Waş, Z.

    2011-03-01

    Theoretical predictions in high energy physics are routinely provided in the form of Monte Carlo generators. Comparisons of predictions from different programs and/or different initialization set-ups are often necessary. MC-TESTER can be used for such tests of decays of intermediate states (particles or resonances) in a semi-automated way. Since 2002 new functionalities were introduced into the package. In particular, it now works with the HepMC event record, the standard for C++ programs. The complete set-up for benchmarking the interfaces, such as interface between τ-lepton production and decay, including QED bremsstrahlung effects is shown. The example is chosen to illustrate the new options introduced into the program. From the technical perspective, our paper documents software updates and supplements previous documentation. As in the past, our test consists of two steps. Distinct Monte Carlo programs are run separately; events with decays of a chosen particle are searched, and information is stored by MC-TESTER. Then, at the analysis step, information from a pair of runs may be compared and represented in the form of tables and plots. Updates introduced in the program up to version 1.24.4 are also documented. In particular, new configuration scripts or script to combine results from multitude of runs into single information file to be used in analysis step are explained. Program summaryProgram title: MC-TESTER, version 1.23 and version 1.24.4 Catalog identifier: ADSM_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSM_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 250 548 No. of bytes in distributed program, including test data, etc.: 4 290 610 Distribution format: tar.gz Programming language: C++, FORTRAN77 Tested and compiled with: gcc 3.4.6, 4.2.4 and 4.3.2 with g77/gfortran Computer: Tested on various platforms Operating system: Tested on operating systems: Linux SLC 4.6 and SLC 5, Fedora 8, Ubuntu 8.2 etc. Classification: 11.9 External routines: HepMC ( https://savannah.cern.ch/projects/hepmc/), PYTHIA8 ( http://home.thep.lu.se/~torbjorn/Pythia.html), LaTeX ( http://www.latex-project.org/) Catalog identifier of previous version: ADSM_v1_0 Journal reference of previous version: Comput. Phys. Comm. 157 (2004) 39 Does the new version supersede the previous version?: Yes Nature of problem: The decays of individual particles are well defined modules of a typical Monte Carlo program chain in high energy physics. A fast, semi-automatic way of comparing results from different programs is often desirable for the development of new programs, in order to check correctness of the installations or for discussion of uncertainties. Solution method: A typical HEP Monte Carlo program stores the generated events in event records such as HepMC, HEPEVT or PYJETS. MC-TESTER scans, event by event, the contents of the record and searches for the decays of the particle under study. The list of the found decay modes is successively incremented and histograms of all invariant masses which can be calculated from the momenta of the particle decay products are defined and filled. The outputs from the two runs of distinct programs can be later compared. A booklet of comparisons is created: for every decay channel, all histograms present in the two outputs are plotted and parameter quantifying shape difference is calculated. Its maximum over every decay channel is printed in the summary table. Reasons for new version: Interface for HepMC Event Record is introduced. Setup for benchmarking the interfaces, such as τ-lepton production and decay, including QED bremsstrahlung effects is introduced as well. This required significant changes in the algorithm. As a consequence, a new version of the code was introduced. Restrictions: Only the first 200 decay channels that were found will initialize histograms and if the multiplicity of decay products in a given channel was larger than 7, histograms will not be created for that channel. Additional comments: New features: HepMC interface, use of lists in definition of histograms and decay channels, filters for decay products or secondary decays to be omitted, bug fixing, extended flexibility in representation of program output, installation configuration scripts, merging multiple output files from separate generations. Running time: Varies substantially with the analyzed decay particle, but generally speed estimation of the old version remains valid. On a PC/Linux with 2.0 GHz processors MC-TESTER increases the run time of the τ-lepton Monte Carlo program TAUOLA by 4.0 seconds for every 100 000 analyzed events (generation itself takes 26 seconds). The analysis step takes 13 seconds; LATEX processing takes additionally 10 seconds. Generation step runs may be executed simultaneously on multiprocessor machines.

  12. Cable tester

    NASA Astrophysics Data System (ADS)

    Rammage, Robert L.

    1990-10-01

    A device for sequentially testing the plurality of connectors in a wiring harness is disclosed. The harness is attached to the tester by means of adapter cables and a rotary switch is used to sequentially, individually test the connectors by passing a current through the connector. If the connector is unbroken, a light will flash to show it is electrically sound. The adapters allow a large number of cable configurations to be tested using a single tester configuration.

  13. A Method for Measuring the Effective Throughput Time Delay in Simulated Displays Involving Manual Control

    NASA Technical Reports Server (NTRS)

    Jewell, W. F.; Clement, W. F.

    1984-01-01

    The advent and widespread use of the computer-generated image (CGI) device to simulate visual cues has a mixed impact on the realism and fidelity of flight simulators. On the plus side, CGIs provide greater flexibility in scene content than terrain boards and closed circuit television based visual systems, and they have the potential for a greater field of view. However, on the minus side, CGIs introduce into the visual simulation relatively long time delays. In many CGIs, this delay is as much as 200 ms, which is comparable to the inherent delay time of the pilot. Because most GCIs use multiloop processing and smoothing algorithms and are linked to a multiloop host computer, it is seldom possible to identify a unique throughput time delay, and it is therefore difficult to quantify the performance of the closed loop pilot simulator system relative to the real world task. A method to address these issues using the critical task tester is described. Some empirical results from applying the method are presented, and a novel technique for improving the performance of GCIs is discussed.

  14. A Computer Program for Testing Grammars On-Line.

    ERIC Educational Resources Information Center

    Gross, Louis N.

    This paper describes a computer system which is intended to aid the linguist in building a transformational grammar. The program operates as a rule tester, performing three services for the user through sets of functions which allow the user to--specify, change, and print base trees (to which transformations would apply); define transformations…

  15. Online Tester for a Symbol Generator

    NASA Technical Reports Server (NTRS)

    Juday, D.; Mcconaugy, K.

    1985-01-01

    About 95 percent of faults detected. Programable instrument periodically checks for failures in system that generates alphanumerical and other symbol voltages for cathode-ray-tube displays. Symbol-generator tester compares gated test-point voltages with predetermined voltage limits while circuit under test performs commanded operation. A go/no-go indication given, depending on whether test voltage is or is not within its specification. Tester in plug-in modular form, temporarily wired to generator test points, or permanently wired to these points.

  16. TUBE TESTER

    DOEpatents

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  17. Explosives tester with heater

    DOEpatents

    Del Eckels, Joel [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Whipple, Richard E [Livermore, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA

    2010-08-10

    An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

  18. Determining the fertility status of Setaria infecting Magnaporthe grisea isolates with standard testers and identification of tolerant cultivar of Setaria italica.

    PubMed

    Karthikeyan, Veluswamy; Gnanamanickam, S S

    2008-10-01

    A total of 128 isolates of Setaria-infecting Magnaporthe grisea strains were obtained from different states of South India which includes sampling sites from Tamil Nadu, two from Karnataka, one from Andhra Pradesh and Kerala. Out of the selected 128 isolates 30 strains were tested with MAT1-1 and MAT1-2 fertile standard testers to determine their mating type. None of the 30 Setaria isolates produced perithecia with fertile testers. However, when monoconidial isolates were mated among themselves, isolates from the same field produced only barren perithecia and the tester isolates were able to mate readily with finger millet isolates. This is the first report of the mating-type studies on Setaria infecting Magnaporthe grisea with standard testers. This result indicates that the Setaria infecting population is infertile. In pathogenicity assay, it was found that 9 out of the 22 Setaria accessions were highly susceptible to Setaria strains of the blast fungus and seven cultivars/accessions were resistant to blast pathogen. Various virulence reactions were scored according to Standard Evaluation System.

  19. Effects of Si content on microstructure and mechanical properties of TiAlN/Si3N4-Cu nanocomposite coatings

    NASA Astrophysics Data System (ADS)

    Feng, Changjie; Hu, Shuilian; Jiang, Yuanfei; Wu, Namei; Li, Mingsheng; Xin, Li; Zhu, Shenglong; Wang, Fuhui

    2014-11-01

    TiAlN/Si3N4-Cu nanocomposite coatings of various Si content (0-5.09 at.%) were deposited on AISI-304 stainless steel by DC reactive magnetron sputtering technique. The chemical composition, microstructure, mechanical and tribological properties of these coatings were systematically investigated by means of X-ray diffraction (XRD), field emission scanning electron microscope (FESEM), nanoindentation tester, a home-made indentation system, a scratch tester and a wear tester. Results indicated that with increasing Si content in these coatings, a reduction of grain size and surface roughness, a transformation of the (1 1 1) preferred orientation was detected by XRD and FESEM. Furthermore the hardness of these coatings increase from 9.672 GPa to 18.628 GPa, and the elastic modulus reveal the rising trend that increase from 224.654 GPa to 251.933 GPa. However, the elastic modulus of TiAlN/Si3N4-Cu coating containing 3.39 at.% Si content dropped rapidly and changed to about 180.775 GPa. The H3/E2 ratio is proportional to the film resistance to plastic deformation. The H3/E2 ratio of the TiAlN/Si3N4-Cu coating containing 3.39 at.% Si content possess of the maximum of 0.11 GPa, and the indentation test indicate that few and fine cracks were observed from its indentation morphologies. The growth pattern of cracks is mainly bending growing. The present results show that the best toughness is obtained for TiAlN/Si3N4-Cu nanocomposite coating containing 3.39 at.% Si content. In addition, the TiAlN/Si3N4-Cu coating containing 3.39 at.% Si content also has good adhesion property and superior wear resistance, and the wear mechanism is mainly adhesion wear.

  20. Non-Intrusive Cable Tester

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.

  1. Effects of postural specific sensorimotor training in patients with chronic low back pain: study protocol for randomised controlled trial.

    PubMed

    McCaskey, Michael A; Schuster-Amft, Corina; Wirth, Brigitte; de Bruin, Eling D

    2015-12-15

    Sensorimotor training (SMT) is popularly applied as a preventive or rehabilitative exercise method in various sports and rehabilitation settings. Yet, there is only low-quality evidence on its effect on pain and function. This randomised controlled trial will investigate the effects of a theory-based SMT in rehabilitation of chronic (>3 months) non-specific low back pain (CNLBP) patients. A pilot study with a parallel, single-blinded, randomised controlled design. Twenty adult patients referred to the clinic for CNLBP treatment will be included, randomised, and allocated to one of two groups. Each group will receive 9 x 30 minutes of standard physiotherapy (PT) treatment. The experimental group will receive an added 15 minutes of SMT. For SMT, proprioceptive postural exercises are performed on a labile platform with adjustable oscillation to provoke training effects on different entry levels. The active comparator group will perform 15 minutes of added sub-effective low-intensity endurance training. Outcomes are assessed on 4 time-points by a treatment blinded tester: eligibility assessment at baseline (BL) 2-4 days prior to intervention, pre-intervention assessment (T0), post-intervention assessment (T1), and at 4 weeks follow-up (FU). At BL, an additional healthy control group (n = 20) will be assessed to allow cross-sectional comparison with symptom-free participants. The main outcomes are self-reported pain (Visual Analogue Scale) and functional status (Oswestry Disability Index). For secondary analysis, postural control variables after an externally perturbed stance on a labile platform are analysed using a video-based marker tracking system and a pressure plate (sagittal joint-angle variability and centre of pressure confidence ellipse). Proprioception is measured as relative cervical joint repositioning error during a head-rotation task. Effect sizes and mixed-model MANOVA (2 groups × 4 measurements for 5 dependent variables) will be calculated. This is the first attempt to systematically investigate effects of a theory-based sensorimotor training in patients with CNLBP. It will provide analysis of several postural segments during a dynamic task for quantitative analysis of quality and change of the task performance in relation to changes in pain and functional status. Trial registry number on cliniclatrials.gov is NCT02304120 , first registered on 17 November 2014.

  2. A portable wheel tester for tyre-road friction and rolling resistance determination

    NASA Astrophysics Data System (ADS)

    Pytka, J.; Budzyński, P.; Tarkowski, P.; Piaskowski, M.

    2016-09-01

    The paper describes theory of operation, design and construction as well as results from primarily experiments with a portable wheel tester that has been developed by the authors as a device for on-site determination of tyre-road braking/driving friction and rolling resistance. The paper includes schematics, drawings, descriptions as well as graphical results form early tests with the presented device. It is expected that the tester can be useful in road accident reconstruction applications as well as in vehicle dynamics research.

  3. Grating visual acuity results in the early treatment for retinopathy of prematurity study.

    PubMed

    Dobson, Velma; Quinn, Graham E; Summers, C Gail; Hardy, Robert J; Tung, Betty; Good, William V

    2011-07-01

    To compare grating (resolution) visual acuity at 6 years of age in eyes that received early treatment (ET) for high-risk prethreshold retinopathy of prematurity (ROP) with that in eyes that underwent conventional management (CM). In a randomized clinical trial, infants with bilateral, high-risk prethreshold ROP (n = 317) had one eye undergo ET and the other eye undergo CM, with treatment only if ROP progressed to threshold severity. For asymmetric cases (n = 84), the high-risk prethreshold eye was randomized to ET or CM. Grating visual acuity measured at 6 years of age by masked testers using Teller acuity cards. Monocular grating acuity results were obtained from 317 of 370 surviving children (85.6%). Analysis of grating acuity results for all study participants with high-risk prethreshold ROP showed no statistically significant overall benefit of ET (18.1% vs 22.8% unfavorable outcomes; P = .08). When the 6-year grating acuity results were analyzed according to a clinical algorithm (high-risk types 1 and 2 prethreshold ROP), a benefit was seen in type 1 eyes (16.4% vs 25.2%; P = .004) undergoing ET, but not in type 2 eyes (21.3% vs 15.9%; P = .29). Early treatment of eyes with type 1 ROP improves grating acuity outcomes, but ET for eyes with type 2 ROP does not. APPLICATION TO CLINICAL MEDICINE: Type 1 eyes should be treated early; however, based on acuity results at 6 years of age, type 2 eyes should be cautiously monitored for progression to type 1 ROP. Trial Registration clinicaltrials.gov Identifier: NCT00027222.

  4. Dielectric Anistropy and Elastic Constants Near the Nematic-Smectic A Transition

    NASA Astrophysics Data System (ADS)

    Visco, Angelo; Mahmood, Rizwan; Zapien, Donald

    The present work examines the behavior of dielectric anisotropy and the elastic constants associated with the deformation of liquid crystal molecules under the influence of an AC electric field and measured by an Automatic Liquid Crystal Tester (ALCT). The systems investigated are of various concentrations of 5CB (4-Cyano-4'-pentylbiphenyl) and 8CB (4-octyl-4'-cyanobiphenyl) liquid crystal as a function of temperature. These studies are important due to the complexity of the coupling between the orientational (nematic) and positional (smectic A) order parameters that can drive this transition to be either continuous or discontinuous. Theoretically, NA transition is weakly first order due to nematic director fluctuations in semctic A phase. This is similar to the transition from normal to superconductor. Thus, there exists a triple point similar to He3/He4 mixtures. Moreover, despite more than four decades of intense work, our understanding of this complex and interesting problem remains unclear. The funding for the project was provided by Slippery Rock University (2015-2016).

  5. An in situ tensile tester for studying electrochemical repassivation behavior: Fabrication and challenges

    NASA Astrophysics Data System (ADS)

    Neelakantan, Lakshman; Schönberger, Bernd; Eggeler, Gunther; Hassel, Achim Walter

    2010-03-01

    An in situ tensile rig is proposed, which allows performing electrochemical (repassivation) experiments during dynamic mechanical testing of wires. Utilizing the basic components of a conventional tensile tester, a custom-made minitensile rig was designed and fabricated. The maximal force that can be measured by the force sensor is 80 N, with a sensitivity of 0.5 mV/V. The maximum travel range of the crosshead induced by the motor is 10 mm with a minimum step size of 0.5 nm. The functionality of the tensile test rig was validated by investigating Cu and shape memory NiTi wires. Wires of lengths between 40 and 50 mm with varying gauge lengths can be tested. An interface between wire and electrochemical setup (noncontact) with a smart arrangement of electrodes facilitated the electrochemical measurements during tensile loading. Preliminary results on the repassivation behavior of Al wire are reported.

  6. Test-retest reproducibility of accommodative facility measures in primary school children.

    PubMed

    Adler, Paul; Scally, Andrew J; Barrett, Brendan T

    2018-05-08

    To determine the test-retest reproducibility of accommodative facility (AF) measures in an unselected sample of UK primary school children. Using ±2.00 DS flippers and a viewing distance of 40 cm, AF was measured in 136 children (range 4-12 years, average 8.1 ± 2.1) by five testers on three occasions (average interval between successive tests: eight days, range 1-21 days). On each occasion, AF was measured monocularly and binocularly, for two minutes. Full datasets were obtained in 111 children (81.6 per cent). Intra-individual variation in AF was large (standard deviation [SD] = 3.8 cycles per minute [cpm]) and there was variation due to the identity of the tester (SD = 1.6 cpm). On average, AF was greater: (i) in monocular compared to binocular testing (by 1.4 cpm, p < 0.001); (ii) in the second minute of testing compared to the first (by 1.3 cpm, p < 0.001); (iii) in older compared to younger children (for example, AF for 4/5-year-olds was 3.3 cpm lower than in children ≥ 10 years old, p = 0.009); and (iv) on subsequent testing occasions (for example, visit-2 AF was 2.0 cpm higher than visit-1 AF, p < 0.001). After the first minute of testing at visit-1, only 36.9 per cent of children exceeded published normative values for AF (≥ 11 cpm monocularly and ≥ 8 cpm binocularly), but this rose to 83.8 per cent after the third test. Using less stringent pass criteria (≥ 6 cpm monocularly and ≥ 3 cpm binocularly), the equivalent figures were 82.9 and 96.4 per cent, respectively. Reduced AF did not co-exist with abnormal near point of accommodation or reduced visual acuity. The results reveal considerable intra-individual variability in raw AF measures in children. When the results are considered as pass/fail, children who initially exhibit normal AF continued to do so on repeat testing. Conversely, the vast majority of children with initially reduced AF exhibit normal performance on repeat testing. Using established pass/fail criteria, the prevalence of persistently reduced AF in this sample is 3.6 per cent. © 2018 Optometry Australia.

  7. Determination of fracture toughness of calcium phosphate coatings deposited onto Ti6Al4V substrate by using indentation technique

    NASA Astrophysics Data System (ADS)

    Aydin, Ibrahim; Cetinel, Hakan; Pasinli, Ahmet

    2012-09-01

    In this study, fracture toughness values of calcium phosphate (CaP) coatings deposited onto Ti6Al4V substrate were determined by using Vickers indentation method. In this new patent holding method, the activation processes were performed with NaOH and NaOH+H2O2 on the Ti6Al4V material surface. Thicknesses of CaP coatings were measured from cross-sections of the samples by using optical microscopy. Vickers indentation tests were performed by using microhardness tester. Young's modulus values of the coatings were determined by using ultra microhardness tester. As a result, fracture toughness (K1C) values of the CaP coatings produced by using two different activation processes, were calculated by using experimental study results. These were found to be 0.43 MPa m1/2 and 0.39 MPa m1/2, respectively. It was determined that the CaP coating on Ti6Al4V activated by NaOH+H2O2 had higher fracture toughness than the CaP coating on Ti6Al4V activated by NaOH.

  8. Reducing Short-Wavelength Blue Light in Dry Eye Patients with Unstable Tear Film Improves Performance on Tests of Visual Acuity.

    PubMed

    Kaido, Minako; Toda, Ikuko; Oobayashi, Tomoo; Kawashima, Motoko; Katada, Yusaku; Tsubota, Kazuo

    2016-01-01

    To investigate whether suppression of blue light can improve visual function in patients with short tear break up time (BUT) dry eye (DE). Twenty-two patients with short BUT DE (10 men, 12 women; mean age, 32.4 ± 6.4 years; age range, 23-43 years) and 18 healthy controls (10 men, 8 women; mean age, 30.1 ± 7.4 years; age range, 20-49 years) underwent functional visual acuity (VA) examinations with and without wearing eyeglasses with 50% blue light blocked lenses. The functional VA parameters were starting VA, functional VA, and visual maintenance ratio. The baseline mean values (logarithm of the minimum angle of resolution, logMAR) of functional VA and the visual maintenance ratio were significantly worse in the DE patients than in the controls (P < 0.05), while no significant difference was observed in the baseline starting VA (P > 0.05). The DE patients had significant improvement in mean functional VA and visual maintenance ratio while wearing the glasses (P < 0.05), while there were no significant changes with and without the glasses in the control group (P > 0.05). Protecting the eyes from short-wavelength blue light may help to ameliorate visual impairment associated with tear instability in patients with DE. This finding represents a new concept, which is that the blue light exposure might be harmful to visual function in patients with short BUT DE.

  9. Reducing Short-Wavelength Blue Light in Dry Eye Patients with Unstable Tear Film Improves Performance on Tests of Visual Acuity

    PubMed Central

    Kaido, Minako

    2016-01-01

    Purpose To investigate whether suppression of blue light can improve visual function in patients with short tear break up time (BUT) dry eye (DE). Methods Twenty-two patients with short BUT DE (10 men, 12 women; mean age, 32.4 ± 6.4 years; age range, 23–43 years) and 18 healthy controls (10 men, 8 women; mean age, 30.1 ± 7.4 years; age range, 20–49 years) underwent functional visual acuity (VA) examinations with and without wearing eyeglasses with 50% blue light blocked lenses. The functional VA parameters were starting VA, functional VA, and visual maintenance ratio. Results The baseline mean values (logarithm of the minimum angle of resolution, logMAR) of functional VA and the visual maintenance ratio were significantly worse in the DE patients than in the controls (P < 0.05), while no significant difference was observed in the baseline starting VA (P > 0.05). The DE patients had significant improvement in mean functional VA and visual maintenance ratio while wearing the glasses (P < 0.05), while there were no significant changes with and without the glasses in the control group (P > 0.05), Conclusions Protecting the eyes from short-wavelength blue light may help to ameliorate visual impairment associated with tear instability in patients with DE. This finding represents a new concept, which is that the blue light exposure might be harmful to visual function in patients with short BUT DE. PMID:27045760

  10. 32 CFR 651.4 - Responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operational testers, producers, users, and disposers) into the decision-making process. (v) Initiate the... environmental perspective, and to ensure that these determinations are part of the Army decision process. (p... agency input into the decision-making process. (5) Ensure that NEPA analysis is prepared and staffed...

  11. Digital Soldering-Iron Tester

    NASA Technical Reports Server (NTRS)

    Buggle, R. N.; Metka, W. H., Jr

    1984-01-01

    Instrument reads tip temperature and contact potential in seconds. Tinned soldering tip touched to temperature sensitive button for 4 seconds and to voltage probe for 1 to 3 seconds. Tip temperature and voltage appear on digital displays. Instrument quickly gives assurance conditions are correct for reliable soldering.

  12. 24 CFR 125.107 - Testers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...

  13. 24 CFR 125.107 - Testers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...

  14. 24 CFR 125.107 - Testers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...

  15. 24 CFR 125.107 - Testers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...

  16. 24 CFR 125.107 - Testers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... FHIP: (a) Testers must not have prior felony convictions or convictions of crimes involving fraud or... not: (1) Have an economic interest in the outcome of the test, without prejudice to the right of any...

  17. SPHERES ultrasound beacon tester floats in Node 1 during Expedition 8

    NASA Image and Video Library

    2004-03-24

    ISS008-E-19132 (24 March 2004) --- The Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) Beacon / Beacon Tester floats in the Unity node of the International Space Station.

  18. From Playroom to Lab: Tough Stretchable Electronics Analyzed with a Tabletop Tensile Tester Made from Toy‐Bricks

    PubMed Central

    Kettlgruber, Gerald; Siket, Christian M.; Drack, Michael; Graz, Ingrid M.; Cakmak, Umut; Major, Zoltan; Kaltenbrunner, Martin; Bauer, Siegfried

    2016-01-01

    Toy bricks are an ideal platform for the cost‐effective rapid prototyping of a tabletop tensile tester with measurement accuracy on par with expensive, commercially available laboratory equipment. Here, a tester is presented that is not only a versatile demonstration device in mechanics, electronics, and physics education and an eye‐catcher on exhibitions, but also a powerful tool for stretchable electronics research. Following the “open‐source movement” the build‐up of the tester is described and all the details for easy reproduction are disclosed. A a new design of highly conformable all‐elastomer based graded rigid island printed circuit boards is developed. Tough bonded to this elastomer substrate are imperceptible electronic foils bearing conductors and off‐the‐shelf microelectronics, paving the way for next generation smart electronic appliances. PMID:27588259

  19. A comparison of damage profiling of automated tap testers on aircraft CFRP panel

    NASA Astrophysics Data System (ADS)

    Mohd Aris, K. D.; Shariff, M. F.; Abd Latif, B. R.; Mohd Haris, M. Y.; Baidzawi, I. J.

    2017-12-01

    The use of composite materials nevertheless is getting more prominent. The combination of reinforcing fibers and matrices will produce the desired strength orientation, tailorability and not to mention the complex shape that is hard to form on metallic structure. The weight percentage of composite materials used in aerospace, civil, marine etc. has increased tremendously. Since composite are stacked together, the possibility of delamination and/disbond defects are highly present either in the monolithic or sandwich structures. Tap test is the cheapest form of nondestructive test to identify the presence of this damage. However, its inconsistency and wide area of coverage can reduce its effectivity since it is carried out manually. The indigenous automated tap tester known as KETOK was used to detect the damage due to trapped voids and air pockets. The mechanism of detection is through controlling the tapping on the surface automatically at a constant rate. Another manual tap tester RD-3 from Wichitech Industries Inc. was used as reference. The acquired data was translated into damage profiling and both results were compared. The results have shown that the indigenous automated tester can profile the damage better when compared with the existing tap tester. As a conclusion, the indigenous automated tap tester has a potential to be used as an IN-SITU damage detection tool to detect delamination and disbond damage on composite panel. However, more conclusive tests need to be done in order to make the unit available to conventional users.

  20. Understand your Algorithm: Drill Down to Sample Visualizations in Jupyter Notebooks

    NASA Astrophysics Data System (ADS)

    Mapes, B. E.; Ho, Y.; Cheedela, S. K.; McWhirter, J.

    2017-12-01

    Statistics are the currency of climate dynamics, but the space of all possible algorithms is fathomless - especially for 4-dimensional weather-resolving data that many "impact" variables depend on. Algorithms are designed on data samples, but how do you know if they measure what you expect when turned loose on Big Data? We will introduce the year-1 prototype of a 3-year scientist-led, NSF-supported, Unidata-quality software stack called DRILSDOWN (https://brianmapes.github.io/EarthCube-DRILSDOWN/) for automatically extracting, integrating, and visualizing multivariate 4D data samples. Based on a customizable "IDV bundle" of data sources, fields and displays supplied by the user, the system will teleport its space-time coordinates to fetch Cases of Interest (edge cases, typical cases, etc.) from large aggregated repositories. These standard displays can serve as backdrops to overlay with your value-added fields (such as derived quantities stored on a user's local disk). Fields can be readily pulled out of the visualization object for further processing in Python. The hope is that algorithms successfully tested in this visualization space will then be lifted out and added to automatic processing toolchains, lending confidence in the next round of processing, to seek the next Cases of Interest, in light of a user's statistical measures of "Interest". To log the scientific work done in this vein, the visualizations are wrapped in iPython-based Jupyter notebooks for rich, human-readable documentation (indeed, quasi-publication with formatted text, LaTex math, etc.). Such notebooks are readable and executable, with digital replicability and provenance built in. The entire digital object of a case study can be stored in a repository, where libraries of these Case Study Notebooks can be examined in a browser. Model data (the session topic) are of course especially convenient for this system, but observations of all sorts can also be brought in, overlain, and differenced or otherwise co-processed. The system is available in various tiers, from minimal-install GUI visualizations only, to GUI+Notebook system, to the full system with the repository software. We seek interested users, initially in a "beta tester" mode with the goodwill to offer reports and requests to help drive improvements in project years 2 and 3.

  1. Michael's Inform Test of Student Ability (M.I.T.O.S.A.). Tester's Manual.

    ERIC Educational Resources Information Center

    Grafius, Thomas M.

    Michael's Informal Test of Student Ability (MITOSA) is a diagnostic evaluative tool for adult students designed to test nine skills abilities in adult students functioning below a tenth grade level. The nine test sections are approximate reading level, understanding of basic math concepts and symbols, general thinking/reasoning ability, eye-hand…

  2. School Psychology in Canada: A Survey of Roles and Functions, Challenges and Aspirations

    ERIC Educational Resources Information Center

    Jordan, Jason J.; Hindes, Yvonne L.; Saklofske, Donald H.

    2009-01-01

    School psychology in Canada has evolved in recent years from being comprised mainly of "testers" to being regarded as an important partner in promoting the psychological and educational needs of children and supporting the mandates of our educational systems. As well, school psychology is now recognized as an area of specialization…

  3. Testing a tool for the classification of study designs in systematic reviews of interventions and exposures showed moderate reliability and low accuracy.

    PubMed

    Hartling, Lisa; Bond, Kenneth; Santaguida, P Lina; Viswanathan, Meera; Dryden, Donna M

    2011-08-01

    To develop and test a study design classification tool. We contacted relevant organizations and individuals to identify tools used to classify study designs and ranked these using predefined criteria. The highest ranked tool was a design algorithm developed, but no longer advocated, by the Cochrane Non-Randomized Studies Methods Group; this was modified to include additional study designs and decision points. We developed a reference classification for 30 studies; 6 testers applied the tool to these studies. Interrater reliability (Fleiss' κ) and accuracy against the reference classification were assessed. The tool was further revised and retested. Initial reliability was fair among the testers (κ=0.26) and the reference standard raters κ=0.33). Testing after revisions showed improved reliability (κ=0.45, moderate agreement) with improved, but still low, accuracy. The most common disagreements were whether the study design was experimental (5 of 15 studies), and whether there was a comparison of any kind (4 of 15 studies). Agreement was higher among testers who had completed graduate level training versus those who had not. The moderate reliability and low accuracy may be because of lack of clarity and comprehensiveness of the tool, inadequate reporting of the studies, and variability in tester characteristics. The results may not be generalizable to all published studies, as the test studies were selected because they had posed challenges for previous reviewers with respect to their design classification. Application of such a tool should be accompanied by training, pilot testing, and context-specific decision rules. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Repeatability of the Oxford Foot Model in children with foot deformity.

    PubMed

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    2018-03-01

    The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in pathological conditions. The aim of the study was to assess the repeatability of the OFM in children with foot deformity. Intra-tester repeatability was assessed for 45 children (15 typically developing, 15 hemiplegic, 15 clubfoot). Inter-tester repeatability was assessed in the clubfoot population. The mean absolute differences between testers (clubfoot) and sessions (clubfoot and hemiplegic) were calculated for each of 15 clinically relevant, kinematic variables and compared to typically developing children. Children with clubfoot showed a mean difference between visits of 2.9° and a mean difference between raters of 3.6° Mean absolute differences were within one degree for the intra and inter-rater reliability in 12/15 variables. Hindfoot rotation, forefoot/tibia abduction and forefoot supination were the most variable between testers. Overall the clubfoot data were less variable than the typically developing population. Children with hemiplegia demonstrated slightly higher differences between sessions (mean 4.1°), with the most reliable data in the sagittal plane, and largest differences in the transverse plane. The OFM was designed to measure different types of foot deformity. The results of this study show that it provides repeatable results in children with foot deformity. To be distinguished from measurement artifact, changes in foot kinematics as a result of intervention or natural progression over time must be greater than the repeatability reported here. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Nonlinear viscoelastic response of highly filled elastomers under multiaxial finite deformation

    NASA Technical Reports Server (NTRS)

    Peng, Steven T. J.; Landel, Robert F.

    1990-01-01

    A biaxial tester was used to obtain precise biaxial stress responses of highly filled, high strain capability elastomers. Stress-relaxation experiments show that the time-dependent part of the relaxation response can be reasonably approximated by a function which is strain and biaxiality independent. Thus, isochronal data from the stress-relaxation curves can be used to determine the stored energy density function. The complex behavior of the elastomers under biaxial deformation may be caused by dewetting.

  6. Limited electromagnetic interference testing of evidential breath testers

    DOT National Transportation Integrated Search

    1983-05-06

    This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...

  7. A Seafloor Test of the A-0-A Approach to Calibrating Pressure Sensors for Vertical Geodesy

    NASA Astrophysics Data System (ADS)

    Wilcock, W. S. D.; Manalang, D.; Harrington, M.; Cram, G.; Tilley, J.; Burnett, J.; Martin, D.; Paros, J. M.

    2017-12-01

    Seafloor geodetic observations are critical for understanding the locking and slip of the megathrust in Cascadia and other subduction zones. Differences of bottom pressure time series have been used successfully in several subduction zones to detect slow-slip earthquakes centered offshore. Pressure sensor drift rates are much greater than the long-term rates of strain build-up and thus, in-situ calibration is required to measure secular strain. One approach to calibration is to use a dead-weight tester, a laboratory apparatus that produces an accurate reference pressure, to calibrate a pressure sensor deployed on the seafloor by periodically switching between the external pressure and the deadweight tester (Cook et al, this session). The A-0-A method replaces the dead weight tester by using the internal pressure of the instrument housing as the reference pressure. We report on the first non-proprietary ocean test of this approach on the MARS cabled observatory at a depth of 900 m depth in Monterey Bay. We use the Paroscientific Seismic + Oceanic Sensors module that is designed for combined geodetic, oceanographic and seismic observations. The module comprises a three-component broadband accelerometer, two pressure sensors that for this deployment measure ocean pressures, A, up to 2000 psia (14 MPa), and a barometer to measure the internal housing reference pressure, 0. A valve periodically switches between external and internal pressures for 5 minute calibrations. The seafloor test started in mid-June and the results of 30 calibrations collected over the first 6 weeks of operation are very encouraging. After correcting for variations in the internal temperature of the housing, the offset of the pressure sensors from the barometer reading as a function of time, can be fit with a straight line for each sensor with a rms misfit of 0.1 hPa (1 mm of water). The slopes of these lines (-4 cm/yr and -0.4 cm/yr) vary by an order of magnitude but the difference in the span (external minus internal pressure) of the two sensors is constant to 0.05 hPa. We will present the results for the first 6 months of A-0-A calibrations for vertical geodesy and also discuss the performance of the pressure sensors and accelerometer for monitoring seismic activity, tilt and ocean infragravity waves.

  8. Transducer Workshop (17th) Held in San Diego, California on June 22-24, 1993

    DTIC Science & Technology

    1993-06-01

    weight in a drop tower, such as the primer tester shown in figure 1. The calibration procedure must be repeated for each lot of copper inserts, and small...force vs. time curve (i.e impulse = area unxer the curve). The FPyF can be used in the primer tester (shown in figure 1) as well as in a weapon...microphones. Plstonphone Output 124 dB, 250 Hz DEAD WEIGHT TESTIER USED AS A PRESSURE RELEASE CALIBRATOR The dead weight tester is designed and most

  9. Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation

    NASA Technical Reports Server (NTRS)

    Lee, Moo Hoon; Durnford, Simon; Crowley, John; Rupert, Angus

    1996-01-01

    Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.

  10. Characterization of wear debris generated in accelerated rolling-element fatigue tests

    NASA Technical Reports Server (NTRS)

    Jones, W. R., Jr.; Parker, R. J.

    1978-01-01

    A ferrographic analysis was used to determine the types and quantities of wear debris generated during accelerated rolling contact fatigue tests. The five-ball rolling contact fatigue tester was used. Ball specimens were made of a corrosion resistant, high-temperature bearing steel. The lubricant was a superrefined naphthenic mineral oil. Conditions included a maximum Hertz stress of 5.52 10 to the 9th power Pa and a shaft speed of 10,000 rpm. Four types of wear debris were observed: (1) normal rubbing wear particles, (2) fatigue microspall particles, (3) spheres, and (4) friction polymer deposits. The characterization of wear debris as a function of time was of limited use in predicting fatigue failures in these accelerated tests.

  11. Associations between Mode of HIV Testing and Consent, Confidentiality, and Referral: A Comparative Analysis in Four African Countries

    PubMed Central

    Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita

    2012-01-01

    Background Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. Methods and Findings The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07–1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06–1.25), compared to integrated testing, but no other associations were statistically significant. Conclusions Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary PMID:23109914

  12. Associations between mode of HIV testing and consent, confidentiality, and referral: a comparative analysis in four African countries.

    PubMed

    Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita

    2012-01-01

    Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT and integrated testers compared with 36% among VCT testers; p<0.001). Adjusted analyses by country show few significant differences by mode of testing: only lower satisfaction among integrated testers in Burkina Faso and Uganda, and lower frequency of referral among PMTCT testers in Malawi. Adjusted analyses of pooled data across countries show a higher likelihood of pre-test meeting for those testing at VCT facilities (adjusted prevalence ratio: 1.22, 95% CI: 1.07-1.38) and higher satisfaction for stand-alone VCT facilities (adjusted prevalence ratio: 1.15; 95% CI: 1.06-1.25), compared to integrated testing, but no other associations were statistically significant. Overall, in this study most respondents reported favorable outcomes for consent, confidentiality, and referral. Provider-initiated ways of delivering testing and counseling do not appear to be associated with less favorable outcomes for clients than traditional, client-initiated VCT, suggesting that testing can be scaled up through multiple modes without detriment to clients' rights. Please see later in the article for the Editors' Summary.

  13. Use of folk tests to detect ciguateric fish: a scientific evaluation of their effectiveness in Raivavae Island (Australes, French Polynesia).

    PubMed

    Darius, H T; Drescher, O; Ponton, D; Pawlowiez, R; Laurent, D; Dewailly, E; Chinain, M

    2013-01-01

    Ciguatera fish poisoning is a seafood intoxication commonly afflicting island communities in the Pacific. These populations, which are strongly dependent on fish resources, have developed over centuries various strategies to decrease the risk of intoxication, including the use of folk tests to detect ciguateric fish. This study aims to evaluate the effectiveness of two folk tests commonly used in Raivavae Island (Australes, French Polynesia): the rigor mortis test (RMT) and the bleeding test (BT). A total of 107 fish were collected in Raivavae Lagoon, among which 80 were tested by five testers using the RMT versus 107 tested by four testers using BT. First, the performance between testers was compared. Second, the efficiency of these tests was compared with toxicity data obtained via the receptor binding assay (RBA) by assessing various parameter's values such as sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV). Comparisons of outcomes between folk tests and RBA analyses were considered: tests used separately or in a parallel versus the series approach by each tester. The overall efficiency of the RMT and BT tests was also evaluated when the judgments of all testers were "pooled". The results demonstrate that efficiencies varied between testers with one showing the best scores in detecting toxic fish: 55% with RMT and 69.2% with BT. BT gave the best results in detecting toxic fish as compared with RMT, giving also better agreement between testers. If high NPV and Se values were to be privileged, the data also suggest that the best way to limit cases of intoxication would be to use RMT and BT tests in a parallel approach. The use of traditional knowledge and a good knowledge of risky versus healthy fishing areas may help reduce the risk of intoxication among communities where ciguatera fish poisoning is highly prevalent.

  14. A cluster-based randomized controlled trial promoting community participation in arsenic mitigation efforts in Bangladesh.

    PubMed

    George, Christine Marie; van Geen, Alexander; Slavkovich, Vesna; Singha, Ashit; Levy, Diane; Islam, Tariqul; Ahmed, Kazi Matin; Moon-Howard, Joyce; Tarozzi, Alessandro; Liu, Xinhua; Factor-Litvak, Pam; Graziano, Joseph

    2012-06-19

    To reduce arsenic (As) exposure, we evaluated the effectiveness of training community members to perform water arsenic (WAs) testing and provide As education compared to sending representatives from outside communities to conduct these tasks. We conducted a cluster based randomized controlled trial of 20 villages in Singair, Bangladesh. Fifty eligible respondents were randomly selected in each village. In 10 villages, a community member provided As education and WAs testing. In a second set of 10 villages an outside representative performed these tasks. Overall, 53% of respondents using As contaminated wells, relative to the Bangladesh As standard of 50 μg/L, at baseline switched after receiving the intervention. Further, when there was less than 60% arsenic contaminated wells in a village, the classification used by the Bangladeshi and UNICEF, 74% of study households in the community tester villages, and 72% of households in the outside tester villages reported switching to an As safe drinking water source. Switching was more common in the outside-tester (63%) versus community-tester villages (44%). However, after adjusting for the availability of arsenic safe drinking water sources, well switching did not differ significantly by type of As tester (Odds ratio = 0.86[95% confidence interval 0.42-1.77). At follow-up, among those using As contaminated wells who switched to safe wells, average urinary As concentrations significantly decreased. The overall intervention was effective in reducing As exposure provided there were As-safe drinking water sources available. However, there was not a significant difference observed in the ability of the community and outside testers to encourage study households to use As-safe water sources. The findings of this study suggest that As education and WAs testing programs provided by As testers, irrespective of their residence, could be used as an effective, low cost approach to reduce As exposure in many As-affected areas of Bangladesh.

  15. (Quickly) Testing the Tester via Path Coverage

    NASA Technical Reports Server (NTRS)

    Groce, Alex

    2009-01-01

    The configuration complexity and code size of an automated testing framework may grow to a point that the tester itself becomes a significant software artifact, prone to poor configuration and implementation errors. Unfortunately, testing the tester by using old versions of the software under test (SUT) may be impractical or impossible: test framework changes may have been motivated by interface changes in the tested system, or fault detection may become too expensive in terms of computing time to justify running until errors are detected on older versions of the software. We propose the use of path coverage measures as a "quick and dirty" method for detecting many faults in complex test frameworks. We also note the possibility of using techniques developed to diversify state-space searches in model checking to diversify test focus, and an associated classification of tester changes into focus-changing and non-focus-changing modifications.

  16. Optimal filter bandwidth for pulse oximetry

    NASA Astrophysics Data System (ADS)

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.

  17. Optimal filter bandwidth for pulse oximetry.

    PubMed

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.

  18. Objective Assessment of Knot-Tying Proficiency With the Fundamentals of Arthroscopic Surgery Training Program Workstation and Knot Tester.

    PubMed

    Pedowitz, Robert A; Nicandri, Gregg T; Angelo, Richard L; Ryu, Richard K N; Gallagher, Anthony G

    2015-10-01

    To assess a new method for biomechanical assessment of arthroscopic knots and to establish proficiency benchmarks using the Fundamentals of Arthroscopic Surgery Training (FAST) Program workstation and knot tester. The first study group included 20 faculty at an Arthroscopy Association of North America resident arthroscopy course (19.9 ± 8.25 years in practice). The second group comprised 30 experienced surgeons attending an Arthroscopy Association of North America fall course (17.1 ± 19.3 years in practice). The training group included 44 postgraduate year 4 or 5 orthopaedic residents in a randomized, prospective study of proficiency-based training, with 3 subgroups: group A, standard training (n = 14); group B, workstation practice (n = 14); and group C, proficiency-based progression using the knot tester (n = 16). Each subject tied 5 arthroscopic knots backed up by 3 reversed hitches on alternating posts. Knots were tied under video control around a metal mandrel through a cannula within an opaque dome (FAST workstation). Each suture loop was stressed statically at 15 lb for 15 seconds. A calibrated sizer measured loop expansion. Knot failure was defined as 3 mm of loop expansion or greater. In the faculty group, 24% of knots "failed" under load. Performance was inconsistent: 12 faculty had all knots pass, whereas 2 had all knots fail. In the second group of practicing surgeons, 21% of the knots failed under load. Overall, 56 of 250 knots (22%) tied by experienced surgeons failed. For the postgraduate year 4 or 5 residents, the aggregate knot failure rate was 26% for the 220 knots tied. Group C residents had an 11% knot failure rate (half the overall faculty rate, P = .013). The FAST workstation and knot tester offer a simple and reproducible educational approach for enhancement of arthroscopic knot-tying skills. Our data suggest that there is significant room for improvement in the quality and consistency of these important arthroscopic skills, even for experienced arthroscopic surgeons. Level II, prospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of a laser road surface tester.

    DOT National Transportation Integrated Search

    1995-01-01

    The purpose of this study was to evaluate the accuracy and usefulness of pavement distress data derived from a laser road surface tester (RST) operating on Virginia's interstate highway system. The evaluation was conducted by comparing rut depth, rou...

  20. Wisconsin mixture characterization using the asphalt mixture performance tester (AMPT) on historical aggregate structures.

    DOT National Transportation Integrated Search

    2010-01-01

    This research evaluated the stiffness and permanent deformation properties of typical Wisconsin Department of : Transportation (WisDOT) asphalt mixtures using the Asphalt Mixture Performance Tester (AMPT) and associated test and : analysis procedures...

  1. 40 CFR 261.21 - Characteristic of ignitability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM Standard D 93-79 or D 93-80 (incorporated by reference, see § 260.11), or a Setaflash Closed Cup Tester, using the test...

  2. 40 CFR 261.21 - Characteristic of ignitability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM Standard D 93-79 or D 93-80 (incorporated by reference, see § 260.11), or a Setaflash Closed Cup Tester, using the test...

  3. Open-source micro-tensile testers via additive manufacturing for the mechanical characterization of thin films and papers

    PubMed Central

    Scheftic, Charlie M.; Brinson, L. Catherine

    2018-01-01

    The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO) paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we propose an alternative hypothesis we term ‘superlamellae consolidation’ to explain the initial deformation of GO paper. The additively manufactured tensile tester tested represents cost savings of >99% compared to commercial solutions in its class and offers simple customization. However, continued development is needed for the tensile tester presented here to approach the technical specifications achievable with commercial solutions. PMID:29813103

  4. Open-source micro-tensile testers via additive manufacturing for the mechanical characterization of thin films and papers.

    PubMed

    Nandy, Krishanu; Collinson, David W; Scheftic, Charlie M; Brinson, L Catherine

    2018-01-01

    The cost of specialized scientific equipment can be high and with limited funding resources, researchers and students are often unable to access or purchase the ideal equipment for their projects. In the fields of materials science and mechanical engineering, fundamental equipment such as tensile testing devices can cost tens to hundreds of thousands of dollars. While a research lab often has access to a large-scale testing machine suitable for conventional samples, loading devices for meso- and micro-scale samples for in-situ testing with the myriad of microscopy tools are often hard to source and cost prohibitive. Open-source software has allowed for great strides in the reduction of costs associated with software development and open-source hardware and additive manufacturing have the potential to similarly reduce the costs of scientific equipment and increase the accessibility of scientific research. To investigate the feasibility of open-source hardware, a micro-tensile tester was designed with a freely accessible computer-aided design package and manufactured with a desktop 3D-printer and off-the-shelf components. To our knowledge this is one of the first demonstrations of a tensile tester with additively manufactured components for scientific research. The capabilities of the tensile tester were demonstrated by investigating the mechanical properties of Graphene Oxide (GO) paper and thin films. A 3D printed tensile tester was successfully used in conjunction with an atomic force microscope to provide one of the first quantitative measurements of GO thin film buckling under compression. The tensile tester was also used in conjunction with an atomic force microscope to observe the change in surface topology of a GO paper in response to increasing tensile strain. No significant change in surface topology was observed in contrast to prior hypotheses from the literature. Based on this result obtained with the new open source tensile stage we propose an alternative hypothesis we term 'superlamellae consolidation' to explain the initial deformation of GO paper. The additively manufactured tensile tester tested represents cost savings of >99% compared to commercial solutions in its class and offers simple customization. However, continued development is needed for the tensile tester presented here to approach the technical specifications achievable with commercial solutions.

  5. Visual recognition and visually guided action after early bilateral lesion of occipital cortex: a behavioral study of a 4.6-year-old girl.

    PubMed

    Amicuzi, Ileana; Stortini, Massimo; Petrarca, Maurizio; Di Giulio, Paola; Di Rosa, Giuseppe; Fariello, Giuseppe; Longo, Daniela; Cannatà, Vittorio; Genovese, Elisabetta; Castelli, Enrico

    2006-10-01

    We report the case of a 4.6-year-old girl born pre-term with early bilateral occipital damage. It was revealed that the child had non-severely impaired basic visual abilities and ocular motility, a selective perceptual deficit of figure-ground segregation, impaired visual recognition and abnormal navigating through space. Even if the child's visual functioning was not optimal, this was the expression of adaptive anatomic and functional brain modifications that occurred following the early lesion. Anatomic brain structure was studied with anatomic MRI and Diffusor Tensor Imaging (DTI)-MRI. This behavioral study may provide an important contribution to understanding the impact of an early lesion of the visual system on the development of visual functions and on the immature brain's potential for reorganisation related to when the damage occurred.

  6. Growth, structural, optical, mechanical and quantum chemical analysis of unidirectional grown bis(guanidinium) 5-sulfosalicylate (BGSSA) single crystal

    NASA Astrophysics Data System (ADS)

    Sreedevi, R.; Saravana Kumar, G.; Amarsingh Bhabu, K.; Balu, T.; Murugakoothan, P.; Rajasekaran, T. R.

    2018-02-01

    Bis(guanidinium) 5-sulfosalicylate single crystal was grown by using Sankaranarayanan-Ramasamy (SR) method from the solution of methanol and water in equimolar ratio. Good quality crystal with 50 mm length and 10 mm in diameter was grown. The grown crystal was subjected to single crystal X-ray diffraction analysis to confirm the crystal structure and it was found to be orthorhombic. UV-Vis-NIR spectroscopic study revealed that the SR method grown crystal had good optical transparency with wide optical band gap of 4.4 eV. The presence of the functional groups and modes of vibrations were identified by FTIR spectroscopy recorded in the range 4000-400 cm-1. The mechanical strength of the grown crystal was confirmed using Vickers microhardness tester by applying load from 25 g to 100 g. Density functional theory (DFT) method with B3LYP/6-31-G (d,p) level basis set was employed and hence the optimized molecular geometry, first order hyperpolarizability, dipole moment, thermodynamic functions, molecular electrostatic potential and frontier molecular orbital analysis of the grown BGSSA sample was computed and analysed.

  7. New reaction tester accurate within 56 microseconds

    NASA Technical Reports Server (NTRS)

    Brown, H.

    1972-01-01

    Testing device measures simple and disjunctive reaction time of human subject to light stimuli. Tester consists of reaction key, logic card, panel mounted neon indicators, and interconnecting wiring. Device is used for determining reaction times of patients undergoing postoperative neurological therapy.

  8. Evaluation of IMS - Swedish Laser road tester : final report.

    DOT National Transportation Integrated Search

    1990-09-01

    A test of the IMS - Swedish Laser road tester was conducted in September 1988. The vehicle mounted laser equipment was used to survey pavement conditions on sections of Oregon's Interstate and non-interstate highway system. : The IMS laser equipment ...

  9. Exploring the Use of a Test Automation Framework

    NASA Technical Reports Server (NTRS)

    Cervantes, Alex

    2009-01-01

    It is known that software testers, more often than not, lack the time needed to fully test the delivered software product within the time period allotted to them. When problems in the implementation phase of a development project occur, it normally causes the software delivery date to slide. As a result, testers either need to work longer hours, or supplementary resources need to be added to the test team in order to meet aggressive test deadlines. One solution to this problem is to provide testers with a test automation framework to facilitate the development of automated test solutions.

  10. Automated Dissolution for Enteric-Coated Aspirin Tablets: A Case Study for Method Transfer to a RoboDis II.

    PubMed

    Ibrahim, Sarah A; Martini, Luigi

    2014-08-01

    Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.

  11. Battery tester

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poljak, M.D.

    1985-08-12

    This abstract discloses an improved battery tester for determining the acceptability of a Lithium Sulfur Dioxide (LiSO/sub 2/) storage battery at a given temperature and with one or more cells therein. The tester is generally made up of a first-comparison circuit having a series of series-interconnected components, namely a comparator, first and second flip-flops, and an AND gate. A first resistor is parallel connected to the first-comparison circuit. A second comparison circuit is also parallel connected to the first-comparison circuit and is generally made up of series-interconnected components, namely a second resistor, a capacitor, a buffer, and a second-comparator. Amore » first switch is connected to the first resistor and a second switch is parallel connected to the second-comparison circuit between the capacitor and the buffer. A logic control arrangement controls the operation of both switches, both comparators, and both flip-flops for testing a battery as to its start-up voltage and performance voltage characteristics all in a relatively short time period. In another embodiment of the tester, it is provided with an analog-to-digital converter, a memory, and a sensor arrangement for enhancing the versatility and reliability of the tester in determining the acceptability of a LiSO/sub 2/ battery.« less

  12. Male recombination in Brazilian populations of Drosophila ananassae.

    PubMed

    Goñi, Beatriz; Matsuda, Muneo; Tobari, Yoshiko N

    2016-07-01

    With few exceptions, spontaneous crossing over does not normally occur in male Drosophila. Drosophila ananassae males show considerable amounts of crossing over. In wild males of D. ananassae from Asian (2008) and Brazilian populations (1986 and 2007) variable frequencies of meiotic crossing over, estimated from chiasmata counts, suggested the existence of factors controlling male crossing over in these populations. To corroborate for such prediction, we present data on spontaneous recombination in F1 males of D. ananassae heterozygous for chromosomes of the same Brazilian populations (1986) and marker chromosomes using three testers stocks. Mean recombination value was low, although high variability existed between individual frequencies. Recombination frequencies between lines in each tester stock were not significantly different, excepting when the 3ple-px and 3ple-cy testers were compared (p < 0.05). These two testers differ in respect to the regional distribution of crossovers. The occurrence of recombination in chromosomes 2 and 3 in F1 males tested with e(65) se; bri ru was not related, suggesting they are under independent genetic control. Our data are consistent with proposed genetic factors controlling male crossing over in the tester stocks and to the presence of enhancers and suppressors of male crossing over segregating in the Brazilian populations (1986).

  13. The Relationship of Motor Coordination, Visual Perception, and Executive Function to the Development of 4–6-Year-Old Chinese Preschoolers' Visual Motor Integration Skills

    PubMed Central

    Fang, Ying; Zhang, Ying

    2017-01-01

    Visual motor integration (VMI) is a vital ability in childhood development, which is associated with the performance of many functional skills. By using the Beery Developmental Test Package and Executive Function Tasks, the present study explored the VMI development and its factors (visual perception, motor coordination, and executive function) among 151 Chinese preschoolers from 4 to 6 years. Results indicated that the VMI skills of children increased quickly at 4 years and peaked at 5 years and decreased at around 5 to 6 years. Motor coordination and cognitive flexibility were related to the VMI development of children from 4 to 6 years. Visual perception was associated with the VMI development at early 4 years and inhibitory control was also associated with it among 4-year-old and the beginning of 5-year-old children. Working memory had no impact on the VMI. In conclusion, the development of VMI skills among children in preschool was not stable but changed dynamically in this study. Meanwhile the factors of the VMI worked in different age range for preschoolers. These findings may give some guidance to researchers or health professionals on improving children's VMI skills in their early childhood. PMID:29457030

  14. Attention and Visual Motor Integration in Young Children with Uncorrected Hyperopia.

    PubMed

    Kulp, Marjean Taylor; Ciner, Elise; Maguire, Maureen; Pistilli, Maxwell; Candy, T Rowan; Ying, Gui-Shuang; Quinn, Graham; Cyert, Lynn; Moore, Bruce

    2017-10-01

    Among 4- and 5-year-old children, deficits in measures of attention, visual-motor integration (VMI) and visual perception (VP) are associated with moderate, uncorrected hyperopia (3 to 6 diopters [D]) accompanied by reduced near visual function (near visual acuity worse than 20/40 or stereoacuity worse than 240 seconds of arc). To compare attention, visual motor, and visual perceptual skills in uncorrected hyperopes and emmetropes attending preschool or kindergarten and evaluate their associations with visual function. Participants were 4 and 5 years of age with either hyperopia (≥3 to ≤6 D, astigmatism ≤1.5 D, anisometropia ≤1 D) or emmetropia (hyperopia ≤1 D; astigmatism, anisometropia, and myopia each <1 D), without amblyopia or strabismus. Examiners masked to refractive status administered tests of attention (sustained, receptive, and expressive), VMI, and VP. Binocular visual acuity, stereoacuity, and accommodative accuracy were also assessed at near. Analyses were adjusted for age, sex, race/ethnicity, and parent's/caregiver's education. Two hundred forty-four hyperopes (mean, +3.8 ± [SD] 0.8 D) and 248 emmetropes (+0.5 ± 0.5 D) completed testing. Mean sustained attention score was worse in hyperopes compared with emmetropes (mean difference, -4.1; P < .001 for 3 to 6 D). Mean Receptive Attention score was worse in 4 to 6 D hyperopes compared with emmetropes (by -2.6, P = .01). Hyperopes with reduced near visual acuity (20/40 or worse) had worse scores than emmetropes (-6.4, P < .001 for sustained attention; -3.0, P = .004 for Receptive Attention; -0.7, P = .006 for VMI; -1.3, P = .008 for VP). Hyperopes with stereoacuity of 240 seconds of arc or worse scored significantly worse than emmetropes (-6.7, P < .001 for sustained attention; -3.4, P = .03 for Expressive Attention; -2.2, P = .03 for Receptive Attention; -0.7, P = .01 for VMI; -1.7, P < .001 for VP). Overall, hyperopes with better near visual function generally performed similarly to emmetropes. Moderately hyperopic children were found to have deficits in measures of attention. Hyperopic children with reduced near visual function also had lower scores on VMI and VP than emmetropic children.

  15. 49 CFR 229.25 - Tests: Every periodic inspection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... dead-weight tester or a test gauge designed for this purpose. (b) All electrical devices and visible... pre-maintenance test reveals that the device is not recording all the specified data and that all... 49 Transportation 4 2013-10-01 2013-10-01 false Tests: Every periodic inspection. 229.25 Section...

  16. 49 CFR 229.25 - Tests: Every periodic inspection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... dead-weight tester or a test gauge designed for this purpose. (b) All electrical devices and visible... pre-maintenance test reveals that the device is not recording all the specified data and that all... 49 Transportation 4 2012-10-01 2012-10-01 false Tests: Every periodic inspection. 229.25 Section...

  17. 49 CFR 229.25 - Tests: Every periodic inspection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... dead-weight tester or a test gauge designed for this purpose. (b) All electrical devices and visible... pre-maintenance test reveals that the device is not recording all the specified data and that all... 49 Transportation 4 2014-10-01 2014-10-01 false Tests: Every periodic inspection. 229.25 Section...

  18. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  19. The accuracy of evidential breath testers at low BACs

    DOT National Transportation Integrated Search

    1989-05-01

    This Technical Note reports on the low blood alcohol concentration (BAC) laboratory testing of seven evidential breath testers widely used by law enforcement. The findings indicated that these devices are just as accurate at low BACs in the 0.020-0.0...

  20. Transformer and Meter Tester

    NASA Technical Reports Server (NTRS)

    Stoms, R. M.

    1984-01-01

    Numerically-controlled 5-axis machine tool uses transformer and meter to determine and indicate whether tool is in home position, but lacks built-in test mode to check them. Tester makes possible test, and repair of components at machine rather then replace them when operation seems suspect.

  1. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

    PubMed

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-03-01

    In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamometer may resolve this. The aim of the present study was therefore to examine the inter-tester reliability concerning strength assessments of isometric hip abduction, adduction, flexion, extension and knee-flexion strength, using HHD with external belt-fixation. Twenty-one healthy athletes (6 women), 30 (8.6) (mean (SD)) years of age, were included. Two physiotherapy students (1 female and 1 male) performed all the measurements after careful instruction and procedure training. Isometric hip abduction, adduction, flexion, extension, and knee-flexion strength were tested. The tester-order and hip-action order were randomised. No systematic between-tester differences (bias) were observed for any of the hip or knee actions. The intra-class correlation coefficients (ICC 2.1) ranged from 0.76 to 0.95. Furthermore, standard errors of measurement in per cent (SEM %) ranged from 5 to 11 %, and minimal detectable change in per cent (MDC %) from 14 to 29 % for the different hip and knee actions. The present study shows that isometric hip- and knee-strength measurements have acceptable inter-tester reliability at the group level, when testing strong individuals, using HHD with belt-fixation. This procedure is therefore perfectly suited for the evaluation and monitoring of strong athletes with hip, groin and hamstring injuries, some of the most common and troublesome injuries in sports. Diagnostic, Level III.

  2. Reliability of McConnell's classification of patellar orientation in symptomatic and asymptomatic subjects.

    PubMed

    Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D

    1999-07-01

    Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.

  3. Global motion perception is related to motor function in 4.5-year-old children born at risk of abnormal development

    PubMed Central

    Chakraborty, Arijit; Anstice, Nicola S.; Jacobs, Robert J.; Paudel, Nabin; LaGasse, Linda L.; Lester, Barry M.; McKinlay, Christopher J. D.; Harding, Jane E.; Wouldes, Trecia A.; Thompson, Benjamin

    2017-01-01

    Global motion perception is often used as an index of dorsal visual stream function in neurodevelopmental studies. However, the relationship between global motion perception and visuomotor control, a primary function of the dorsal stream, is unclear. We measured global motion perception (motion coherence threshold; MCT) and performance on standardized measures of motor function in 606 4.5-year-old children born at risk of abnormal neurodevelopment. Visual acuity, stereoacuity and verbal IQ were also assessed. After adjustment for verbal IQ or both visual acuity and stereoacuity, MCT was modestly, but significantly, associated with all components of motor function with the exception of gross motor scores. In a separate analysis, stereoacuity, but not visual acuity, was significantly associated with both gross and fine motor scores. These results indicate that the development of motion perception and stereoacuity are associated with motor function in pre-school children. PMID:28435122

  4. 21 CFR 882.1410 - Electroencephalograph electrode/lead tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroencephalograph electrode/lead tester. 882.1410 Section 882.1410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1410...

  5. 21 CFR 882.1410 - Electroencephalograph electrode/lead tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroencephalograph electrode/lead tester. 882.1410 Section 882.1410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1410...

  6. 21 CFR 870.2370 - Electrocardiograph surface electrode tester.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrocardiograph surface electrode tester. 870.2370 Section 870.2370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2370...

  7. 21 CFR 870.2370 - Electrocardiograph surface electrode tester.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrocardiograph surface electrode tester. 870.2370 Section 870.2370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2370...

  8. Explosives tester

    DOEpatents

    Haas, Jeffrey S [San Ramon, CA; Howard, Douglas E [Livermore, CA; Eckels, Joel D [Livermore, CA; Nunes, Peter J [Danville, CA

    2011-01-11

    An explosives tester that can be used anywhere as a screening tool by non-technical personnel to determine whether a surface contains explosives. First and second explosives detecting reagent holders and dispensers are provided. A heater is provided for receiving the first and second explosives detecting reagent holders and dispensers.

  9. PCB tester selection for future systems. Volume 2. Final report, August 1989-June 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitt, W.

    1992-06-01

    This report describes a computer program (to run on an IBM compatible PC) designed to aid in the selection of a PCB tester, given the characteristics of the PC board to be tested. The program contains a limited data base of PCB testers, and others may be added easily. This report also provides a specification for a limited family of PCB testers to fill the gap between what the U.S. Air Force is expected to need and what is expected to be available within the next four to six years. The parameters used in the computer program and the specificationmore » are based on a survey of military and commercial PCBs - both those now available and those expected to come on line within the next four to six years. The results of the survey are covered in volume 2 - available from DTIC. Automatic Test Equipment, Technology Forecast, Air Force Avionics.« less

  10. PCB tester selection for future systems. Volume 1. Final report, August 1989-June 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitt, W.

    1992-06-01

    This report describes a computer program (to run on an IBM compatible PC) designed to aid in the selection of a PCB tester, given the characteristics of the PC board to be tested. The program contains a limited data base of PCB testers, and others may be added easily. This report also provides a specification for a limited family of PCB testers to fill the gap between what the U.S. Air Force is expected to need and what is expected to be available within the next four to six years. The parameters used in the computer program and the specificationmore » are based on a survey of military and commercial PCBs - both those now available and those expected to come on line within the next four to six years. The results of the survey are covered in volume 2 - available from DTIC. Automatic Test Equipment, Technology Forecast, Air Force Avionics.« less

  11. Comparing Perceptions with Actual Reports of Close Friend's HIV Testing Behavior Among Urban Tanzanian Men.

    PubMed

    Mulawa, Marta; Yamanis, Thespina J; Balvanz, Peter; Kajula, Lusajo J; Maman, Suzanne

    2016-09-01

    Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men's uptake of testing by correcting misperceptions about testing norms, we compare men's perceptions of their closest friend's HIV testing behaviors with the friend's actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men's HIV testing.

  12. Comparing Perceptions with Actual Reports of Close Friend’s HIV Testing Behavior Among Urban Tanzanian Men

    PubMed Central

    Yamanis, Thespina J.; Balvanz, Peter; Kajula, Lusajo J.; Maman, Suzanne

    2016-01-01

    Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men’s uptake of testing by correcting misperceptions about testing norms, we compare men’s perceptions of their closest friend’s HIV testing behaviors with the friend’s actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men’s HIV testing. PMID:26880322

  13. Functional and visual acuity outcomes of cataract surgery in Timor-Leste (East Timor).

    PubMed

    Naidu, Girish; Correia, Marcelino; Nirmalan, Praveen; Verma, Nitin; Thomas, Ravi

    2014-12-01

    To report functional outcomes following cataract surgery in Timor-Leste. Pre- and post-intervention study measuring visual function improvement following cataract surgery. Presenting visual acuity (VA) was measured and visual function documented using the Indian vision function questionnaire (IND-VFQ). All 174 persons undergoing cataract surgery from November 2009 to January 2011 in Timor-Leste were included. Mean age was 65.4 years; 113 (64.9%) were male, 143 (82.1%) were from a rural background and 151 (86.8%) were illiterate. Pre-operatively, 77 of 174 patients (44.3%, 95% confidence interval, CI, 37.0-51.7%) were blind (VA ≤3/60), 77 (44.3%, 95% CI 37.0-51.7%) were visually impaired (VA <6/18->3/60), while 20 (11.5%, 95% CI 7.4-16.9%) had presenting acuity ≥6/18 in the better eye. Following surgery, significant improvement in visual function was demonstrated by an effect size of 2.8, 3.7 and 3.9 in the domains of general functioning, psychosocial impact and visual symptoms, respectively. Four weeks following surgery, 85 patients (48.9%, 95% CI 41.5-66.3%) had a presenting VA ≥6/18, 74 (42.5%, 95% CI 35.3-45.9%) were visually impaired and 15 (8.6%, 95% CI 5.0-13.6%) were blind. IND-VFQ improvement occurred even in patients remaining visually impaired or blind following surgery. In this setting, cataract surgery led to a significant improvement in visual function but the VA results did not meet World Health Organization quality criteria. IND-VFQ results, although complementary to clinical VA outcomes did not, in isolation, reflect the need to improve program quality.

  14. Attributes Effecting Software Testing Estimation; Is Organizational Trust an Issue?

    ERIC Educational Resources Information Center

    Hammoud, Wissam

    2013-01-01

    This quantitative correlational research explored the potential association between the levels of organizational trust and the software testing estimation. This was conducted by exploring the relationships between organizational trust, tester's expertise, organizational technology used, and the number of hours, number of testers, and time-coding…

  15. The Sally-Anne test: an interactional analysis of a dyadic assessment.

    PubMed

    Korkiakangas, Terhi; Dindar, Katja; Laitila, Aarno; Kärnä, Eija

    2016-11-01

    The Sally-Anne test has been extensively used to examine children's theory of mind understanding. Many task-related factors have been suggested to impact children's performance on this test. Yet little is known about the interactional aspects of such dyadic assessment situations that might contribute to the ways in which children respond to the test questions. To examine the interactional factors contributing to the performance of two children in the Sally-Anne test. To identify the interactional practices used by the tester administering the task and to describe how interactional features can pose challenges in the critical belief and reality questions for both the tester and the testee. The Sally-Anne test was carried out as part of a project examining children's interactions in a technology-enhanced environment. The present study uses video recordings of two children with communication disorders (one with a current diagnosis of autism spectrum disorder [ASD]) and an adult tester. We draw on a multimodal approach to conversation analysis (CA) to examine the sequential organization of the test questions and answers. The children drew on diverse resources when producing responses to the test questions: responding verbally, pointing or manually handling objects. The tester treated these responses differently depending on how they were produced. When the child pointed at an object and verbally indicated their response, the tester moved on to the next question apparently accepting the child's answer. When the child manually handled an object or produced a quiet verbal response, the tester repeated the question indicating that the child's actions did not constitute an adequate response to a test question. In response to this, both children modified or changed their previous responses. Through monitoring each other, the tester and the child produced actions highly responsive to the features of each other's conduct, which underpinned the conduct of the test itself. Children's responses in the test might not be solely indicative of socio-cognitive capacities but also show orientation to interactional nuances. The study proposes that children can demonstrate diverse ways of responding to questions, yet testers may treat these as test-irrelevant behaviours if they do not correspond to the scoring criteria. A video-based CA study can broaden our understanding of children's pragmatic competencies in responsiveness that may not always embody an expected form. This can have implications for the development of future assessment tasks and revision of existing scoring practices. © 2016 Royal College of Speech and Language Therapists.

  16. Credit WCT. Original 21/4"x21/4" color negative is housed in the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Original 2-1/4"x2-1/4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. At one time, Building 4285/E-86 accommodated tensile testing of propellant samples. This view shows a tensile strength tester set up for propellant tests, under the supervision of JPL staff member Milton Clay (JPL negative no. JPL-10291AC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Casting & Curing Building, Edwards Air Force Base, Boron, Kern County, CA

  17. Comparison of anesthetic efficacy of 4% articaine with 1:100,000 epinephrine and 2% lidocaine with 1:80,000 epinephrine for inferior alveolar nerve block in patients with irreversible pulpitis.

    PubMed

    Sood, Ravi; Hans, Manoj-Kumar; Shetty, Shashit

    2014-12-01

    This study was done to compare the anesthetic efficacy of 4% articaine with 1:100,000 epinephrine with that of 2% lidocaine with 1:80,000 epinephrine during pulpectomy in patients with irreversible pulpitis for inferior alveolar nerve block in mandibular posterior teeth. Patients with irreversible pulpitis referred to the Department of Conservative Dentistry and Endodontics, K.D. Dental College, randomly received a conventional inferior alveolar nerve block containing 1.8 mL of either 4% articaine with 1:100,000 epinephrine or 2% lidocaine with 1:80,000 epinephrine. After the patient's subjective assessment of lip anesthesia, the absence/presence of pulpal anesthesia through electric pulp stimulation was recorded and the absence/presence of pain was recorded through visual analogue scale. The pulpal anesthesia success for articaine (76%) was slightly more than with lidocaine (58%) as measured with pulp tester as well as for the pain reported during the procedure the success rate of articaine (88%) was slightly more than that of lidocaine (82%) although the difference between the two solutions was not statistically significant. Both the local anesthetic solutions had similar effects on patients with irreversible pulpitis when used for inferior alveolar nerve block. Key words:Anesthesia, articaine, lignocaine, pulpitis.

  18. Comparison of anesthetic efficacy of 4% articaine with 1:100,000 epinephrine and 2% lidocaine with 1:80,000 epinephrine for inferior alveolar nerve block in patients with irreversible pulpitis

    PubMed Central

    Sood, Ravi; Shetty, Shashit

    2014-01-01

    Objectives: This study was done to compare the anesthetic efficacy of 4% articaine with 1:100,000 epinephrine with that of 2% lidocaine with 1:80,000 epinephrine during pulpectomy in patients with irreversible pulpitis for inferior alveolar nerve block in mandibular posterior teeth. Material and Methods: Patients with irreversible pulpitis referred to the Department of Conservative Dentistry and Endodontics, K.D. Dental College, randomly received a conventional inferior alveolar nerve block containing 1.8 mL of either 4% articaine with 1:100,000 epinephrine or 2% lidocaine with 1:80,000 epinephrine. After the patient’s subjective assessment of lip anesthesia, the absence/presence of pulpal anesthesia through electric pulp stimulation was recorded and the absence/presence of pain was recorded through visual analogue scale. Results: The pulpal anesthesia success for articaine (76%) was slightly more than with lidocaine (58%) as measured with pulp tester as well as for the pain reported during the procedure the success rate of articaine (88%) was slightly more than that of lidocaine (82%) although the difference between the two solutions was not statistically significant. Conclusions: Both the local anesthetic solutions had similar effects on patients with irreversible pulpitis when used for inferior alveolar nerve block. Key words:Anesthesia, articaine, lignocaine, pulpitis. PMID:25674319

  19. Effect of pain-free range exercise on shoulder pain and range of motion in an amateur skier.

    PubMed

    Yoo, Won-Gyu

    2016-12-01

    [Purpose] This study prescribed pain-free range exercises for a female amateur skier who complained of limitations in her shoulder range of motion, and pain caused by protective spasms; the tester evaluated the effects of such exercise on pain. [Subject and Methods] A 23-year-old female who complained of pain of 3 weeks in duration in the right glenohumoral and scapulothoracic joints was enrolled. [Results] After pain-free range exercises, the visual analog pain score was 2 and the shoulder flexion and abduction angles improved compared to the initial values. [Conclusion] Thus, this study suggests muscle-strengthening exercises within the pain-free range, rather than simple pain treatments, as therapy for acute muscle injuries in skiers.

  20. Functional Visual Improvement After Cataract Surgery in Eyes With Age-Related Macular Degeneration: Results of the Ophthalmic Surgical Outcomes Data Project.

    PubMed

    Stock, Michael V; Vollman, David E; Baze, Elizabeth F; Chomsky, Amy S; Daly, Mary K; Lawrence, Mary G

    2015-04-01

    To determine if cataract surgery on eyes with AMD confers as much functional visual improvement as surgery on eyes without retinal pathology. This is a retrospective analysis of 4924 cataract surgeries from the Veterans Healthcare Administration Ophthalmic Surgical Outcomes Data Project (OSOD). We included cases of eyes with AMD that had both preoperative and postoperative NEI-VFQ-25 questionnaires submitted and compared their outcomes with controls without retinal pathology. We excluded patients with other retinal pathologies (740 patients). The analyses compared changes in visual acuity and overall functional visual improvement and its subscales using t-tests, multivariate logistic regressions, and linear regression modeling. Preoperative and postoperative questionnaires were submitted by 58.3% of AMD and 63.8% of no retinal pathology cases (controls). Analysis of overall score showed that cataract surgery on eyes with AMD led to increased visual function (13.8 ± 2.4 NEI-VFQ units, P < 0.0001); however, increases were significantly less when compared with controls (-6.4 ± 2.9 NEI-VFQ units, P < 0.0001). Preoperative best-corrected visual acuity (preBCVA) in AMD was predictive of postoperative visual function (r = -0.38, P < 0.0001). In controls, postoperative visual function was only weakly associated with preBCVA (r = -0.075, P = 0.0002). Patients with AMD with vision of 20/40 or better had overall outcomes similar to controls (-2.2 ± 4.7 NEI-VFQ units, P = 0.37). Cataract surgery on eyes with AMD offers an increase in functional visual improvement; however, the amount of benefit is associated with the eye's preBCVA. For eyes with preBCVA of 20/40 or greater, the improvement is similar to that of patients without retinal pathology. However, if preBCVA is less than 20/40, the amount of improvement was shown to be significantly less and decreased with decreasing preBCVA.

  1. ASSOCIATION BETWEEN VISUAL FUNCTION AND SUBRETINAL DRUSENOID DEPOSITS IN NORMAL AND EARLY AGE-RELATED MACULAR DEGENERATION EYES.

    PubMed

    Neely, David; Zarubina, Anna V; Clark, Mark E; Huisingh, Carrie E; Jackson, Gregory R; Zhang, Yuhua; McGwin, Gerald; Curcio, Christine A; Owsley, Cynthia

    2017-07-01

    To examine the association between subretinal drusenoid deposits (SDDs) identified by multimodal retinal imaging and visual function in older eyes with normal macular health or in the earliest phases of age-related macular degeneration (AMD). Age-related macular degeneration status for each eye was defined according to the Age-Related Eye Disease Study (AREDS) 9-step classification system (normal = Step 1, early AMD = Steps 2-4) based on color fundus photographs. Visual functions measured were best-corrected photopic visual acuity, contrast and light sensitivity, mesopic visual acuity, low-luminance deficit, and rod-mediated dark adaptation. Subretinal drusenoid deposits were identified through multimodal imaging (color fundus photographs, infrared reflectance and fundus autofluorescence images, and spectral domain optical coherence tomography). The sample included 1,202 eyes (958 eyes with normal health and 244 eyes with early AMD). In normal eyes, SDDs were not associated with any visual function evaluated. In eyes with early AMD, dark adaptation was markedly delayed in eyes with SDDs versus no SDD (a 4-minute delay on average), P = 0.0213. However, this association diminished after age adjustment, P = 0.2645. Other visual functions in early AMD eyes were not associated with SDDs. In a study specifically focused on eyes in normal macular health and in the earliest phases of AMD, early AMD eyes with SDDs have slower dark adaptation, largely attributable to the older ages of eyes with SDD; they did not exhibit deficits in other visual functions. Subretinal drusenoid deposits in older eyes in normal macular health are not associated with any visual functions evaluated.

  2. Motor skills of children with unilateral visual impairment in the Infant Aphakia Treatment Study.

    PubMed

    Celano, Marianne; Hartmann, E Eugenie; DuBois, Lindreth G; Drews-Botsch, Carolyn

    2016-02-01

    To assess motor functioning in children aged 4 years 6 months enrolled in the Infant Aphakia Treatment Study, and to determine contributions of visual acuity and stereopsis to measured motor skills. One hundred and four children (53% female) with unilateral aphakia randomized to intraocular lens or contact lens treatment were evaluated at 4 years 6 months (age range 4y 6mo-4y 11mo) for monocular recognition visual acuity, motor skills, and stereopsis by a traveling examiner masked to treatment condition. Motor skills were assessed with the Movement Assessment Battery for Children--Second Edition (MABC-2). Visual acuity was operationalized as log10 of the minimum angle of resolution (logMAR) value for treated eye, best logMAR value for either eye, and intraocular logMAR difference. Student's t-tests showed no significant differences in MABC-2 scores between the intraocular lens and contact lens groups. The mean total score was low (6.43; 18th centile) compared with the normative reference group. Motor functioning was not related to visual acuity in the treated eye or to intraocular logMAR difference, but was predicted in a regression model by the better visual acuity of either eye (usually the fellow eye), even after accounting for the influence of age at surgery, examiner, orthotropic ocular alignment, and stereopsis. Children with unilateral congenital cataract may have delayed motor functioning at 4 years 6 months, which may adversely affect their social and academic functioning. © 2015 Mac Keith Press.

  3. What Do Battery Testers Test?

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1996-01-01

    Presents activities to determine whether it is better to test dry cells with an ammeter than with a voltmeter and how best to test alkaline batteries. Discusses classification of disposable testers as instruments. Concludes that a laboratory voltmeter gives a good indication of the condition of an alkaline cell while carbon batteries are best…

  4. USING BASE-SPECIFIC SALMONELLA TESTER STRAINS TO CHARACTERIZE THE TYPES OF MUTATION INDUCED BY BENZIDINE AND BENZIDINE CONGENERS AFTER REDUCTIVE METABOLISM

    EPA Science Inventory

    Abstract
    Benzidine, 4-aminobiphenyl, 3,3'-dichlorobenzidine HCl, 3,3'-dimethylbenzidine, 3,3'- dimethoxybenzidine and benzidine congener-based dye trypan blue were mutagenic in Salmonella typhimurium TAl 00 only with metabolic activation. It was found that a hamster liver 89 ...

  5. A Longitudinal Behavioral Genetic Analysis of Task Persistence

    ERIC Educational Resources Information Center

    Deater-Deckard, Kirby; Petrill, Stephen A.; Thompson, Lee A.; DeThorne, Laura S.

    2006-01-01

    Change in task persistence was assessed in two annual assessments using teachers', testers', and observers' ratings. Participants included 79 monozygotic and 116 same-sex dizygotic twin pairs who were in Kindergarten or 1st grade (4.3 to 7.9 years old) at the initial assessment. Task persistence was widely distributed and higher among older…

  6. Galvanic Corrosion Initiatives

    DTIC Science & Technology

    1987-12-01

    Blair, Incorporated Baldwin Tensile Tester, Model #472470, Southwark Division, Tate-Emery Company Extensometer, Model #P3M, Satec , Incorporated...8217%, , q% % A - 6.0" 3.0൉ -~ 4.0" .25"’ 2.0 tesl es pcme .Ř 3.00 B.~~~~~~ inuatn slee pee %, %. % Z-,P ENVIRONMENTS , The environments for this

  7. 16 CFR § 1500.43 - Method of test for flashpoint of volatile flammable materials by Tagliabue open-cup apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... is placed snugly in holes drilled in the rim of the bath, so that the guide wire is 5/8-inch from the... black. Procedure 4. (a) Place the tester on a solid table free of vibration, in a location free of...

  8. A method to determine the impact of reduced visual function on nodule detection performance.

    PubMed

    Thompson, J D; Lança, C; Lança, L; Hogg, P

    2017-02-01

    In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (-1.00 D and -2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1-4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to -1.00 D and for one observer when defocussed to -2.00 D. Stereoacuity was unacceptable for one observer when defocussed to -2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  9. Comparative assessment of the microhardness and plastic degradation mechanism of deposited modulated coatings on mild steel

    NASA Astrophysics Data System (ADS)

    Fayomi, O. S. I.; Anawe, P. A. L.; Inegbenebor, A. O.; Udoye, N. E.

    2018-05-01

    Zinc based coatings modified with aluminium and tin inclusions were electrodeposited in chloride zinc sulfate electrolytes containing a metallic powder of titanium. It was found that presence of these particulates is suitable to obtain ZnAlSn-Ti composites coating that could help increase the microhardnesss characteristics and wear properties. The hardness and wear properties of the deposited coatings were examined with diamond base micro-hardness tester and CETR reciprocating sliding tester respectively. The structural properties were examined with the help of scanning electron microscope. It was observed that structural coating surface impact on the hardness propagation with increases from 33.4 to 299 kgf mm-2 (HVN40), and shows a considerably higher wear resistance from 2.351g/min to 0.002g/min. It is obvious that plastic deformation of the working steel structure is dependent on protective coating and the concentration of the individual particulate.

  10. W5″ Test: A simple method for measuring mean power output in the bench press exercise.

    PubMed

    Tous-Fajardo, Julio; Moras, Gerard; Rodríguez-Jiménez, Sergio; Gonzalo-Skok, Oliver; Busquets, Albert; Mujika, Iñigo

    2016-11-01

    The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p < .01) and detecting training-induced changes (R(2): 0.78). Good to excellent intra-tester (intraclass correlation coefficient (ICC) range: 0.81-0.97) and excellent inter-tester (ICC range: 0.96-0.99; coefficient of variation range: 2.4-4.1%) reliability was found for all loads. The W5″ Test was shown to be a valid, reliable and sensitive method for measuring mean power output during the bench press exercise in subjects who have previous resistance training experience.

  11. Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in an Open Kinetic Chain.

    PubMed

    Romero-Franco, Natalia; Montaño-Munuera, Juan Antonio; Fernández-Domínguez, Juan Carlos; Jiménez-Reyes, Pedro

    2017-12-18

    New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared to closed kinetic chain movements. To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. The validity, inter-tester and intra-tester reliability of a digital inclinometer for measuring knee JPS were evaluated. Sports research laboratory. Eighteen athletes (11 males and 7 females; 28.4 ± 6.6 years; 71.9 ± 14.0 kg; 1.77 ± 0.09 m; 22.8 ± 3.2 kg/m 2 ) voluntary participated in this study. Absolute angular error (AAE), relative angular error (RAE) and variable angular error (VAE) of knee JPS in an OKC. Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared to the video analysis in JPS tasks (AAE: ICC = 0.981, SEM = 0.08; RAE: ICC = 0.974, SEM = 0.12; VAE: ICC = 0.973, SEM = 0.07). Inter-tester reliability was also excellent for all the proprioceptive errors (AAE: ICC = 0.967, SEM = 0.04; RAE: ICC = 0.974, SEM = 0.03; VAE: ICC = 0.939, SEM = 0.08). Similar results were obtained for intra-tester reliability (AAE: ICC = 0.861, SEM = 0.1; RAE: ICC = 0.894, SEM = 0.1; VAE: ICC = 0.700, SEM = 0.2). The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.

  12. Visual impairment in Finnish Usher syndrome type III.

    PubMed

    Plantinga, Rutger F; Pennings, Ronald J E; Huygen, Patrick L M; Sankila, Eeva-Marja; Tuppurainen, Kaija; Kleemola, Leenamaija; Cremers, Cor W R J; Deutman, August F

    2006-02-01

    To evaluate visual impairment in Finnish Usher syndrome type 3 (USH3) and compare this with visual impairment in Usher syndrome types 1b (USH1b) and 2a (USH2a). We carried out a retrospective study of 28 Finnish USH3 patients, 24 Dutch USH2a patients and 17 Dutch USH1b patients. Cross-sectional regression analyses of the functional acuity score (FAS), functional field score (FFS*) and functional vision score (FVS*) related to age were performed for all patients. The FFS* and FVS* were calculated using the isoptre V-4 test target instead of the usual III-4 target. Statistical tests relating to regression lines and Student's t-test were used to compare between USH3 patients and the other genetic subtypes of Usher syndrome. Cross-sectional analyses revealed significant deterioration in the FAS (1.3% per year), FFS* (1.4% per year) and FVS* (1.8% per year) with advancing age in the USH3 patient group. At a given age the USH3 patients showed significantly poorer visual field function than the USH2a patients. The rate of deterioration in visual function in Finnish USH3 patients was fairly similar to that in Dutch USH1b or USH2a patients. At a given age, visual field impairment in USH3 patients was similar to that in USH1b patients but poorer than in USH2a patients.

  13. Four-year follow-up of corneal aberrations and visual functions of myopic patients after laser in situ keratomileusis

    PubMed Central

    Liu, Tai-Xiang; Chen, Yong-Tao; Dan, Ting-Ting; Shi, Rong; Linghu, Shao-Rong; Li, Hai-Xiang

    2015-01-01

    Objective: To report on 4-year follow-up of corneal higher-order aberrations and daily visual functions of myopic patients after laser in situ keratomileusis (LASIK). Methods: One hundred thirty four eyes of 67 patients who underwent LASIK guided by aspherical ablation were included in this study. The vision, corneal spherical aberration (SphA) and Coma were recorded before LASIK and at 6 month and 4 year after LASIK. The evaluation of the questionnaire about daily visual functions was performed by the same physician after LASIK. Results: No eye decreased the BCVA during 4 year follow-up. The effect index and safety index were 1.08±0.16, 1.11±0.17 and 1.12±0.16, 1.13±0.14 respectively at 6 month and 4 year post-LASIK. After LASIK the corneal SphA and Coma were significantly increased, however the difference between 6 month and 4 year post-LASIK was no statistical significance. Most patients (94.3%-92.4%) felt satisfaction or high satisfaction about the ability to perform each daily visual function after LASIK. Meanwhile there was still about 7.4%-9.2% patients who complained that they could not drive at night. Further analysis showed that the score of driving at night was negative correlation with corneal SphA (r=-0.645, p=0.040; r=-0.688, p=0.040 at 6 month and 4 year post-LASIK respectively). Conclusions: Our four-year follow-up outcomes indicated that the myopic patients after LASIK had the long-term stable corneal aberration and satisfaction of daily visual functions. PMID:26870114

  14. Integration of color, orientation, and size functional domains in the ventral pathway

    PubMed Central

    Ghose, Geoffrey M.; Ts’o, Daniel Y.

    2017-01-01

    Abstract. Functional specialization within the extrastriate areas of the ventral pathway associated with visual form analysis is poorly understood. Studies comparing the functional selectivities of neurons within the early visual areas have found that there are more similar than different between the areas. We simultaneously imaged visually evoked activation over regions of V2 and V4 and parametrically varied three visual attributes for which selectivity exists in both areas: color, orientation, and size. We found that color selective regions were observed in both areas and were of similar size and spatial distribution. However, two major areal distinctions were observed: V4 contained a greater number and diversity of color-specific regions than V2 and exhibited a higher degree of overlap between domains for different functional attributes. In V2, size and color regions were largely segregated from orientation domains, whereas in V4 both color and size regions overlapped considerably with orientation regions. Our results suggest that higher-order composite selectivities in the extrastriate cortex may arise organically from the interactions afforded by an overlap of functional domains for lower order selectivities. PMID:28573155

  15. USAF bioenvironmental noise data handbook. Volume 168: MB-3 tester, pressurized cabin leakage, aircraft

    NASA Astrophysics Data System (ADS)

    Rau, T. H.

    1982-06-01

    The MB-3 Tester is an electric motor-driven cabin leakage tester designed to furnish pressurized air to the aircraft at controlled pressures and temperatures during ground pressurization of aircraft cockpits and pressurized compartments. This report provides measured data defining the bioacoustic environments produced by this unit operating at a normal rated/load condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.

  16. Adjuvant or radical fractionated stereotactic radiotherapy for patients with pituitary functional and nonfunctional macroadenoma

    PubMed Central

    2011-01-01

    Purpose To evaluate the efficacy and toxicity of stereotactic fractionated radiotherapy (SFRT) for patients with pituitary macroadenoma (PMA). Methods and Materials Between March 2000 and March 2009, 27 patients (male to female ratio, 1.25) with PMA underwent SFRT (median dose, 50.4 Gy). Mean age of the patients was 56.5 years (range, 20.3 - 77.4). In all but one patient, SFRT was administered for salvage treatment after surgical resection (transphenoidal resection in 23, transphenoidal resection followed by craniotomy in 2 and multiple transphenoidal resections in another patient). In 10 (37%) patients, the PMAs were functional (3 ACTH-secreting, 3 prolactinomas, 2 growth hormone-secreting and 2 multiple hormone-secretion). Three (11.1%) and 9 (33.3%) patients had PMA abutting and compressing the optic chiasm, respectively. Mean tumor volume was 2.9 ± 4.6 cm3. Eighteen (66.7%) patients had hypopituitarism prior to SFRT. The mean follow-up period after SFRT was 72.4 ± 37.2 months. Results Tumor size decreased for 6 (22.2%) patients and remained unchanged for 19 (70.4%) other patients. Two (7.4%) patients had tumor growth inside the prescribed treatment volume. The estimated 5-year tumor growth control was 95.5% after SFRT. Biochemical remission occurred in 3 (30%) patients with functional PMA. Two patients with normal anterior pituitary function before SFRT developed new deficits 25 and 65 months after treatment. The 5-year survival without new anterior pituitary deficit was thus 95.8%. Five patients with visual field defect had improved visual function and 1 patient with no visual defect prior to SFRT, but an optic chiasm abutting tumor, had a decline in visual function. The estimated 5-year vision and pituitary function preservation rates were 93.2% and 95.8%, respectively. Conclusions SFRT is a safe and effective treatment for patients with PMA, although longer follow-up is needed to evaluate long-term outcomes. In this study, approximately 1 patient with visual field defect out of two had an improved visual function. PMID:22152397

  17. Fractal aspects of the flow and shear behaviour of free-flowable particle size fractions of pharmaceutical directly compressible excipient sorbitol.

    PubMed

    Hurychová, Hana; Lebedová, Václava; Šklubalová, Zdenka; Dzámová, Pavlína; Svěrák, Tomáš; Stoniš, Jan

    Flowability of powder excipients is directly influenced by their size and shape although the granulometric influence of the flow and shear behaviour of particulate matter is not studied frequently. In this work, the influence of particle size on the mass flow rate through the orifice of a conical hopper, and the cohesion and flow function was studied for four free-flowable size fractions of sorbitol for direct compression in the range of 0.080-0.400 mm. The particles were granulometricaly characterized using an optical microscopy; a boundary fractal dimension of 1.066 was estimated for regular sorbitol particles. In the particle size range studied, a non-linear relationship between the mean particle size and the mass flow rate Q10 (g/s) was detected having amaximum at the 0.245mm fraction. The best flow properties of this fraction were verified with aJenike shear tester due to the highest value of flow function and the lowest value of the cohesion. The results of this work show the importance of the right choice of the excipient particle size to achieve the best flow behaviour of particulate material.Key words: flowability size fraction sorbitol for direct compaction Jenike shear tester fractal dimension.

  18. Global motion perception is related to motor function in 4.5-year-old children born at risk of abnormal development.

    PubMed

    Chakraborty, Arijit; Anstice, Nicola S; Jacobs, Robert J; Paudel, Nabin; LaGasse, Linda L; Lester, Barry M; McKinlay, Christopher J D; Harding, Jane E; Wouldes, Trecia A; Thompson, Benjamin

    2017-06-01

    Global motion perception is often used as an index of dorsal visual stream function in neurodevelopmental studies. However, the relationship between global motion perception and visuomotor control, a primary function of the dorsal stream, is unclear. We measured global motion perception (motion coherence threshold; MCT) and performance on standardized measures of motor function in 606 4.5-year-old children born at risk of abnormal neurodevelopment. Visual acuity, stereoacuity and verbal IQ were also assessed. After adjustment for verbal IQ or both visual acuity and stereoacuity, MCT was modestly, but significantly, associated with all components of motor function with the exception of fine motor scores. In a separate analysis, stereoacuity, but not visual acuity, was significantly associated with both gross and fine motor scores. These results indicate that the development of motion perception and stereoacuity are associated with motor function in pre-school children. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Design and development of an automated NEMA traffic signal controller tester : executive summary, August 2000.

    DOT National Transportation Integrated Search

    2000-08-01

    Traffic signal system controllers designed to meet the NEMA TS1 Standards are one of the most prevalent types in use in the US and Canada as of this writing. A PC-based tester for testing NEMA TS1 traffic signal controllers has been developed as a pa...

  20. Design and development of an automated NEMA traffic signal controller tester : final report, August 2000.

    DOT National Transportation Integrated Search

    2000-08-01

    Traffic signal system controllers designed to meet the NEMA TS1 Standards are one of the most prevalent types in use in the US and Canada as of this writing. A PC-based tester for testing NEMA TS1 traffic signal controllers has been developed as a pa...

  1. Operational Test Director Guide. Change 4.

    DTIC Science & Technology

    1982-09-20

    usable by the people invol - ved; the testers, the data collectors, and the evaluators. Sample formats are available to the OTD in (Change 1) 10-4 4 a...to & educe the e6jeetA o the timiting 6aetoxA. FoL exampte, "Avai- * abte ta/getA do not tepiteaent iteaLL~tic thkeatA. Howevek, 3-3 CLASSIFICATION...related test equipment and special tools. (e) (*) Completed NAVSUP Form 1250, with part number and APL number (or nomenclature of parent equipment), for

  2. Hybrid maize breeding with doubled haploids: II. Optimum type and number of testers in two-stage selection for general combining ability.

    PubMed

    Longin, C Friedrich H; Utz, H Friedrich; Melchinger, Albrecht E; Reif, Jochen C

    2007-02-01

    Optimum allocation of test resources is of crucial importance for the efficiency of breeding programs. Our objectives were to (1) determine the optimum allocation of the number of lines, test locations, as well as number and type of testers in hybrid maize breeding using doubled haploids with two breeding strategies for improvement of general combining ability (GCA), (2) compare the maximum selection gain (DeltaG) achievable under both strategies, and (3) give recommendations for the optimum implementation of doubled haploids in commercial hybrid maize breeding. We calculated DeltaG by numerical integration for two two-stage selection strategies with evaluation of (1) testcross performance in both stages (BS1) or (2) line per se performance in the first stage followed by testcross performance in the second stage (BS2). Different assumptions were made regarding the budget, variance components (VCs), and the correlation between line per se performance and GCA. Selection gain for GCA increased with a broader genetic base of the tester. Hence, testers combining a large number of divergent lines are advantageous. However, in applied breeding programs, the use of single- or double-cross testers in the first and inbred testers in the second selection stage may be a good compromise between theoretical and practical requirements. With a correlation between line per se performance and GCA of 0.50, DeltaG for BS1 is about 5% higher than for BS2, if an economic weight of line per se performance is neglected. With increasing economic weight of line per se performance, relative efficiency of BS2 increased rapidly resulting in a superiority of BS2 over BS1 already for an economic weight for line per se performance larger than 0.1. Considering the importance of an economic seed production, an economic weight larger than 0.1 seems realistic indicating the necessity of separate breeding strategies for seed and pollen parent heterotic groups.

  3. Effects of early maternal docosahexaenoic acid intake on neuropsychological status and visual acuity at five years of age of breast-fed term infants.

    PubMed

    Jensen, Craig L; Voigt, Robert G; Llorente, Antolin M; Peters, Sarika U; Prager, Thomas C; Zou, Yali L; Rozelle, Judith C; Turcich, Marie R; Fraley, J Kennard; Anderson, Robert E; Heird, William C

    2010-12-01

    We previously reported better psychomotor development at 30 months of age in infants whose mothers received a docosahexaenoic acid (DHA) (22:6n-3) supplement for the first 4 months of lactation. We now assess neuropsychological and visual function of the same children at 5 years of age. Breastfeeding women were assigned to receive identical capsules containing either a high-DHA algal oil (∼200 mg/d of DHA) or a vegetable oil (containing no DHA) from delivery until 4 months postpartum. Primary outcome variables at 5 years of age were measures of gross and fine motor function, perceptual/visual-motor function, attention, executive function, verbal skills, and visual function of the recipient children at 5 years of age. There were no differences in visual function as assessed by the Bailey-Lovie acuity chart, transient visual evoked potential or sweep visual evoked potential testing between children whose mothers received DHA versus placebo. Children whose mothers received DHA versus placebo performed significantly better on the Sustained Attention Subscale of the Leiter International Performance Scale (46.5 ± 8.9 vs 41.9 ± 9.3, P < .008) but there were no statistically significant differences between groups on other neuropsychological domains. Five-year-old children whose mothers received modest DHA supplementation versus placebo for the first 4 months of breastfeeding performed better on a test of sustained attention. This, along with the previously reported better performance of the children of DHA-supplemented mothers on a test of psychomotor development at 30 months of age, suggests that DHA intake during early infancy confers long-term benefits on specific aspects of neurodevelopment. Copyright © 2010 Mosby, Inc. All rights reserved.

  4. Clinically Meaningful Rehabilitation Outcomes of Low Vision Patients Served by Outpatient Clinical Centers.

    PubMed

    Goldstein, Judith E; Jackson, Mary Lou; Fox, Sandra M; Deremeik, James T; Massof, Robert W

    2015-07-01

    To facilitate comparative clinical outcome research in low vision rehabilitation, we must use patient-centered measurements that reflect clinically meaningful changes in visual ability. To quantify the effects of currently provided low vision rehabilitation (LVR) on patients who present for outpatient LVR services in the United States. Prospective, observational study of new patients seeking outpatient LVR services. From April 2008 through May 2011, 779 patients from 28 clinical centers in the United States were enrolled in the Low Vision Rehabilitation Outcomes Study. The Activity Inventory, a visual function questionnaire, was administered to measure overall visual ability and visual ability in 4 functional domains (reading, mobility, visual motor function, and visual information processing) at baseline and 6 to 9 months after usual LVR care. The Geriatric Depression Scale, Telephone Interview for Cognitive Status, and Medical Outcomes Study 36-Item Short-Form Health Survey physical functioning questionnaires were also administered to measure patients' psychological, cognitive, and physical health states, respectively, and clinical findings of patients were provided by study centers. Mean changes in the study population and minimum clinically important differences in the individual in overall visual ability and in visual ability in 4 functional domains as measured by the Activity Inventory. Baseline and post-rehabilitation measures were obtained for 468 patients. Minimum clinically important differences (95% CIs) were observed in nearly half (47% [95% CI, 44%-50%]) of patients in overall visual ability. The prevalence rates of patients with minimum clinically important differences in visual ability in functional domains were reading (44% [95% CI, 42%-48%]), visual motor function (38% [95% CI, 36%-42%]), visual information processing (33% [95% CI, 31%-37%]), and mobility (27% [95% CI, 25%-31%]). The largest average effect size (Cohen d = 0.87) for the population was observed in overall visual ability. Age (P = .006) was an independent predictor of changes in overall visual ability, and logMAR visual acuity (P = .002) was predictive of changes in visual information processing. Forty-four to fifty percent of patients presenting for outpatient LVR show clinically meaningful differences in overall visual ability after LVR, and the average effect sizes in overall visual ability are large, close to 1 SD.

  5. Electromyographic Assessment of Functional Symmetry of Paraspinal Muscles during Static Exercises in Adolescents with Idiopathic Scoliosis

    PubMed Central

    Chwała, Wiesław; Koziana, Agnieszka; Kasperczyk, Tadeusz; Płaszewski, Maciej

    2014-01-01

    Background. The question of how to correct and rehabilitate scoliosis remains one of the most difficult problems of orthopaedics. Controversies continue to arise regarding various types of both symmetric and asymmetric scoliosis-specific therapeutic exercises. Objective. The aim of the present paper was to conduct an electromyographic assessment of functional symmetry of paraspinal muscles during symmetric and asymmetric exercises in adolescents with idiopathic scoliosis. Materials and Methods. The study was conducted in a group of 82 girls, mean age 12.4 ± 2.3 years with single- or double-major-idiopathic scoliosis, Cobb angle 24 ± 9.4°. The functional biopotentials during isometric work of paraspinal muscles in “at rest” position and during two symmetric and four asymmetric exercises were measured with the use of the Muscle Tester ME 6000 electromyograph. Results. In general, asymmetric exercises were characterised by larger differences in bioelectrical activity of paraspinal muscles, in comparison with symmetric exercises, both in the groups of patients with single-curve and double-curve scoliosis. Conclusion. During symmetric and asymmetric exercises, muscle tension patterns differed significantly in both groups, in comparison with the examination at rest, in most cases generating positive corrective patterns. Asymmetric exercises generated divergent muscle tension patterns on the convex and concave sides of the deformity. PMID:25258713

  6. Visual functions and disability in diabetic retinopathy patients

    PubMed Central

    Shrestha, Gauri Shankar; Kaiti, Raju

    2013-01-01

    Purpose This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. Method A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. Result The majority of subjects (42.1%) were of the age group 60–70 years. Best corrected visual acuity was found to be 0.73 ± 0.2 in the better eye and 0.93 ± 0.27 in the worse eye, which was significantly different at p = 0.002. Visual disability scores were significantly higher for legibility of letters (1.2 ± 0.3) and sentences (1.4 ± 0.4), and least for clothing (0.7 ± 0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Conclusion Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. PMID:24646899

  7. Visual functions and disability in diabetic retinopathy patients.

    PubMed

    Shrestha, Gauri Shankar; Kaiti, Raju

    2014-01-01

    This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. The majority of subjects (42.1%) were of the age group 60-70 years. Best corrected visual acuity was found to be 0.73±0.2 in the better eye and 0.93±0.27 in the worse eye, which was significantly different at p=0.002. Visual disability scores were significantly higher for legibility of letters (1.2±0.3) and sentences (1.4±0.4), and least for clothing (0.7±0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  8. Genome-Wide Architecture of Disease Resistance Genes in Lettuce

    PubMed Central

    Christopoulou, Marilena; Wo, Sebastian Reyes-Chin; Kozik, Alex; McHale, Leah K.; Truco, Maria-Jose; Wroblewski, Tadeusz; Michelmore, Richard W.

    2015-01-01

    Genome-wide motif searches identified 1134 genes in the lettuce reference genome of cv. Salinas that are potentially involved in pathogen recognition, of which 385 were predicted to encode nucleotide binding-leucine rich repeat receptor (NLR) proteins. Using a maximum-likelihood approach, we grouped the NLRs into 25 multigene families and 17 singletons. Forty-one percent of these NLR-encoding genes belong to three families, the largest being RGC16 with 62 genes in cv. Salinas. The majority of NLR-encoding genes are located in five major resistance clusters (MRCs) on chromosomes 1, 2, 3, 4, and 8 and cosegregate with multiple disease resistance phenotypes. Most MRCs contain primarily members of a single NLR gene family but a few are more complex. MRC2 spans 73 Mb and contains 61 NLRs of six different gene families that cosegregate with nine disease resistance phenotypes. MRC3, which is 25 Mb, contains 22 RGC21 genes and colocates with Dm13. A library of 33 transgenic RNA interference tester stocks was generated for functional analysis of NLR-encoding genes that cosegregated with disease resistance phenotypes in each of the MRCs. Members of four NLR-encoding families, RGC1, RGC2, RGC21, and RGC12 were shown to be required for 16 disease resistance phenotypes in lettuce. The general composition of MRCs is conserved across different genotypes; however, the specific repertoire of NLR-encoding genes varied particularly of the rapidly evolving Type I genes. These tester stocks are valuable resources for future analyses of additional resistance phenotypes. PMID:26449254

  9. 49 CFR 173.120 - Class 3-Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Closed Cup Tester, (ASTM D 56) (IBR; see § 171.7 of this subchapter); (B) Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus, (ASTM D 3278) (IBR; see § 171.7 of this subchapter... for Flash Point by Pensky-Martens Closed Cup Tester, (ASTM D 93) (IBR; see § 171.7 of this subchapter...

  10. Relative sensitivity of clinical tests to hydrophilic lens-induced corneal thickness changes.

    PubMed

    Elliott, D B; Fonn, D; Flanagan, J; Doughty, M

    1993-12-01

    The relative sensitivity of the van den Berg Straylightmeter, slitlamp biomicroscopy, a modified optical pachometer, Bailey-Lovie logMAR visual acuity (VA), and two glare tests (The Brightness Acuity Tester used with 10% contrast VA and Pelli-Robson contrast sensitivity) to hydrophilic contact lens-induced edema was assessed in 19 subjects (mean age 25.9 +/- 4.5 years). After baseline assessments, subjects wore thick hydrogel lenses on one eye which was patched tightly for 3 h. Assessments were repeated at frequent intervals after lens removal to assess recovery. None of the pachometer measurements returned to baseline within the 2-h monitoring period, although the majority were within 2% of baseline corneal thickness. The average time for the Straylightmeter scores to recover to baseline values after the lens removal was 90 min, which was similar to the time when visible edema at the slitlamp disappeared. The average time for return to baseline of logMAR VA and the two glare tests was consistently two to three times shorter than the time for the Straylightmeter score. The Straylightmeter therefore provided assessments of corneal edema similar to slitlamp examination and was more sensitive than VA or glare testing.

  11. Arrestin 1 and Cone Arrestin 4 Have Unique Roles in Visual Function in an All-Cone Mouse Retina.

    PubMed

    Deming, Janise D; Pak, Joseph S; Shin, Jung-A; Brown, Bruce M; Kim, Moon K; Aung, Moe H; Lee, Eun-Jin; Pardue, Machelle T; Craft, Cheryl Mae

    2015-12-01

    Previous studies discovered cone phototransduction shutoff occurs normally for Arr1-/- and Arr4-/-; however, it is defective when both visual arrestins are simultaneously not expressed (Arr1-/-Arr4-/-). We investigated the roles of visual arrestins in an all-cone retina (Nrl-/-) since each arrestin has differential effects on visual function, including ARR1 for normal light adaptation, and ARR4 for normal contrast sensitivity and visual acuity. We examined Nrl-/-, Nrl-/-Arr1-/-, Nrl-/-Arr4-/-, and Nrl-/-Arr1-/-Arr4-/- mice with photopic electroretinography (ERG) to assess light adaptation and retinal responses, immunoblot and immunohistochemical localization analysis to measure retinal expression levels of M- and S-opsin, and optokinetic tracking (OKT) to measure the visual acuity and contrast sensitivity. Study results indicated that Nrl-/- and Nrl-/-Arr4-/- mice light adapted normally, while Nrl-/-Arr1-/- and Nrl-/-Arr1-/-Arr4-/- mice did not. Photopic ERG a-wave, b-wave, and flicker amplitudes followed a general pattern in which Nrl-/-Arr4-/- amplitudes were higher than the amplitudes of Nrl-/-, while the amplitudes of Nrl-/-Arr1-/- and Nrl-/-Arr1-/-Arr4-/- were lower. All three visual arrestin knockouts had faster implicit times than Nrl-/- mice. M-opsin expression is lower when ARR1 is not expressed, while S-opsin expression is lower when ARR4 is not expressed. Although M-opsin expression is mislocalized throughout the photoreceptor cells, S-opsin is confined to the outer segments in all genotypes. Contrast sensitivity is decreased when ARR4 is not expressed, while visual acuity was normal except in Nrl-/-Arr1-/-Arr4-/-. Based on the opposite visual phenotypes in an all-cone retina in the Nrl-/-Arr1-/- and Nrl-/-Arr4-/- mice, we conclude that ARR1 and ARR4 perform unique modulatory roles in cone photoreceptors.

  12. The four-meter confrontation visual field test.

    PubMed Central

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests. PMID:1494829

  13. The four-meter confrontation visual field test.

    PubMed

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests.

  14. Physical dimensions, torsional performance, bending properties, and metallurgical characteristics of rotary endodontic instruments. VI. Canal Master drills.

    PubMed

    Luebke, N H; Brantley, W A; Sabri, Z I; Luebke, F L; Lausten, L L

    1995-05-01

    A laboratory study was performed on machine-driven Canal Master drills to determine their physical dimensions, torsional performance, bending properties, and metallurgical characteristics in fracture. Physical dimensions were determined for each of the available sizes (#50 to #100) of Canal Master drills from the manufacturer that distributes these instruments in the United States. Samples were also tested in clockwise torsion using a Maillefer memocouple. Bending properties of cantilever specimens were measured with a Tinius Olsen stiffness tester. Bending fatigue testing was performed on a unique laboratory apparatus. Scanning electron microscope examination confirmed visual observations that the stainless steel Canal Master drills exhibited ductile torsional fracture. This study is part of a continuing investigation to establish standards for all machine-driven rotary endodontic instruments.

  15. Environmental Testing and Thermal Analysis of the NPS Solar Cell Array Tester (NPS-SCAT) CubeSat

    DTIC Science & Technology

    2011-06-01

    BCR Battery Charge Regulator C&DH Command and Data Handling CAD Computer Aided Design CDR Critical Design Review CFT Comprehensive Functional Test ...CPT Comprehensive Performance Test CoM Center of Mass COTS Commercial Off-the-Shelf CTB Cargo Transfer Bag EDU Engineering Design Unit EPS...and inexpensive solution. 2 C. ENVIRONMENTAL TESTING Environmental testing is an important element of the design and testing of a satellite. By

  16. Investigation of microstructural alterations in M50 and 52100 steel using nanoindentation

    NASA Astrophysics Data System (ADS)

    Paulson, Kristin R.

    Bearing steels are used in rolling elements and are designed to withstand heavy loads for an extended period of time. At the end of life, microstructural alterations within the material have been observed and are linked to failure. In this study, a three ball-on-rod fatigue tester was used to test M50 and 52100 steel cylindrical rods at differing loads of 4.0 GPa, 4.5 GPa, and 5.0 GPa and in lubricated and unlubricated conditions to 108 cycles in an attempt to produce microstructural alterations. Microstructural alterations characterized as butterflies were observed and investigated further in two M50 samples that were tested at 4.5 GPa to 10 8 cycles in the lubricated and unlubricated condition. Microstructural alterations characterized as dark etching regions (DER), and white etching bands (WEBs) were not observed. Additionally, hardness was investigated cross sectionally as a function of depth and location within the wear track produced by the fatigue test. No conclusive evidence was derived from the hardness measurements as a function of depth in relation to the formation of microstructural alterations or the stress experienced subsurface within the material. Hardness measurements performed specifically within a butterfly wing, however, returned hardness values significantly higher than the matrix hardness values.

  17. A longitudinal study of visual function in carriers of X-linked recessive retinitis pigmentosa.

    PubMed

    Grover, S; Fishman, G A; Anderson, R J; Lindeman, M

    2000-02-01

    This study was carried out to evaluate the progression of visual function impairment in carriers of X-linked recessive retinitis pigmentosa. We also assessed the relationship between the retinal findings at presentation and the extent of deterioration. Observational, retrospective, case series. Twenty-seven carriers of X-linked recessive retinitis pigmentosa. Each carrier was clinically categorized into one of four grades (grades 0 through 3) depending on the presence or absence of a tapetal-like retinal reflex and the extent of peripheral pigmentary degeneration. A complete ophthalmologic examination was performed and data for visual acuity, visual field area, and electroretinographic measurements were collected on the most recent visit in both eyes. These were then compared with similar data obtained on their initial visits. A comparison of visual function was carried out between the initial visit and the most recent visit on each carrier. The visual acuity was measured with Snellen's acuity charts. The visual fields to targets V-4-e and II-4-e were planimeterized and used for the analysis. The electroretinographic (ERG) measures used were light-adapted single-flash b-wave amplitudes and 30-Hz red flicker for cone function, dark-adapted maximal b-wave amplitudes, and response to a low intensity blue-flash for rod function. None of the 11 carriers with a tapetal-like reflex only (grade 1) showed any significant change in visual acuity or fields as compared with 3 of 7 (43%) carriers with diffuse peripheral pigmentary findings (grade 3) who showed significant deterioration in visual acuity in at least one eye, and 6 of 7 (86%) who showed a significant decrease in visual field area with at least one target size in at least one eye. By comparison, only 1 of 10 carriers with a grade 1 fundus finding demonstrated a significant decrease in maximal dark-adapted ERG function as compared with 5 of 6 (83%) carriers with grade 3 in response to a single-flash stimulus and with 4 of 5 (80%) carriers in response to a single-flash blue stimulus. For the single-flash photopic response, none of the 10 carriers with grade 1 showed any significant deterioration, whereas 2 of 4 (50%) with grade 3 did show such deterioration. The ERG responses for carriers with grade 2 were in between the extent of decrease in ERG amplitudes of those in carriers with grades 1 and 3. In our cohort of X-linked retinitis pigmentosa carriers, those with only a tapetal-like retinal reflex at presentation had a better prognosis to retain visual function than those with peripheral retinal pigmentation. These data are useful in counseling such carriers as to their visual prognosis.

  18. Structural, dielectric and ferroelectric studies of BZT doped Mg0.2Cu0.3Zn0.5Fe2O4 magnetoelectric composites

    NASA Astrophysics Data System (ADS)

    Khader, S. Abdul; Parveez, Asiya; Giridharan, N. V.; Sankarappa, T.

    2018-05-01

    The composites of ferrite-ferroelectric system (x) Mg0.2Cu0.3Zn0.5Fe2O4+ (1-x) Ba0.8Zr0.2TiO3 (x=15%, 30%, 45%) were synthesized by sintering mixtures of ferroelectric Ba0.8Zr0.2TiO3 (BZT) and ferrite component Mg0.2Cu0.3Zn0.5Fe2O4 (MCZF). The presences of two phases in magneto-electric composites were probed by X-ray diffraction (XRD) studies. The peaks observed in the XRD spectrum indicated spinel cubic structure for MCZF ferrite and tetragonal perovskite structure for BZT and, both spinel and pervoskite structures for synthesized composites. Surface morphology of the samples has been investigated using Field Emission Scanning Electron Microscope (FESEM). Frequency dependent dielectric properties of synthesized composites were measured from 100 Hz to 1 MHz at RT using HIOKI LCR HI-TESTER. The dielectric dispersion is observed at lower frequencies for the synthesized ME composites. The ferroelectric properties of synthesized composites were analyzed using a Precision ferroelectric tester. It is observed that the composites exhibited ferroelectric hysteresis with wide loops indicating lossy nature of composites.

  19. Contact Behavior of Composite CrTiSiN Coated Dies in Compressing of Mg Alloy Sheets under High Pressure

    PubMed Central

    Yang, T.S.; Yao, S.H.; Chang, Y.Y.; Deng, J.H.

    2018-01-01

    Hard coatings have been adopted in cutting and forming applications for nearly two decades. The major purpose of using hard coatings is to reduce the friction coefficient between contact surfaces, to increase strength, toughness and anti-wear performance of working tools and molds, and then to obtain a smooth work surface and an increase in service life of tools and molds. In this report, we deposited a composite CrTiSiN hard coating, and a traditional single-layered TiAlN coating as a reference. Then, the coatings were comparatively studied by a series of tests. A field emission SEM was used to characterize the microstructure. Hardness was measured using a nano-indentation tester. Adhesion of coatings was evaluated using a Rockwell C hardness indentation tester. A pin-on-disk wear tester with WC balls as sliding counterparts was used to determine the wear properties. A self-designed compression and friction tester, by combining a Universal Testing Machine and a wear tester, was used to evaluate the contact behavior of composite CrTiSiN coated dies in compressing of Mg alloy sheets under high pressure. The results indicated that the hardness of composite CrTiSiN coating was lower than that of the TiAlN coating. However, the CrTiSiN coating showed better anti-wear performance. The CrTiSiN coated dies achieved smooth surfaces on the Mg alloy sheet in the compressing test and lower friction coefficient in the friction test, as compared with the TiAlN coating. PMID:29316687

  20. Three-dimensional measurement of yarn hairiness via multiperspective images

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Xu, Bugao; Gao, Weidong

    2018-02-01

    Yarn hairiness is one of the essential parameters for assessing yarn quality. Most of the currently used yarn measurement systems are based on two-dimensional (2-D) photoelectric measurements, which are likely to underestimate levels of yarn hairiness because hairy fibers on a yarn surface are often projected or occluded in these 2-D systems. A three-dimensional (3-D) test method for hairiness measurement using a multiperspective imaging system is presented. The system was developed to reconstruct a 3-D yarn model for tracing the actual length of hairy fibers on a yarn surface. Five views of a yarn from different perspectives were created by two angled mirrors and simultaneously captured in one panoramic picture by a camera. A 3-D model was built by extracting the yarn silhouettes in the five views and transferring the silhouettes into a common coordinate system. From the 3-D model, curved hair fibers were traced spatially so that projection and occlusion occurring in the current systems could be avoided. In the experiment, the proposed method was compared with two commercial instruments, i.e., the Uster Tester and Zweigle Tester. It is demonstrated that the length distribution of hairy fibers measured from the 3-D model showed an exponential growth when the fiber length is sorted from shortest to longest. The hairiness measurements, such as H-value, measured by the multiperspective method were highly consistent with those of Uster Tester (r=0.992) but had larger values than those obtained from Uster Tester and Zweigle Tester, proving that the proposed method corrected underestimated hairiness measurements in the commercial systems.

  1. Contact Behavior of Composite CrTiSiN Coated Dies in Compressing of Mg Alloy Sheets under High Pressure.

    PubMed

    Yang, T S; Yao, S H; Chang, Y Y; Deng, J H

    2018-01-08

    Hard coatings have been adopted in cutting and forming applications for nearly two decades. The major purpose of using hard coatings is to reduce the friction coefficient between contact surfaces, to increase strength, toughness and anti-wear performance of working tools and molds, and then to obtain a smooth work surface and an increase in service life of tools and molds. In this report, we deposited a composite CrTiSiN hard coating, and a traditional single-layered TiAlN coating as a reference. Then, the coatings were comparatively studied by a series of tests. A field emission SEM was used to characterize the microstructure. Hardness was measured using a nano-indentation tester. Adhesion of coatings was evaluated using a Rockwell C hardness indentation tester. A pin-on-disk wear tester with WC balls as sliding counterparts was used to determine the wear properties. A self-designed compression and friction tester, by combining a Universal Testing Machine and a wear tester, was used to evaluate the contact behavior of composite CrTiSiN coated dies in compressing of Mg alloy sheets under high pressure. The results indicated that the hardness of composite CrTiSiN coating was lower than that of the TiAlN coating. However, the CrTiSiN coating showed better anti-wear performance. The CrTiSiN coated dies achieved smooth surfaces on the Mg alloy sheet in the compressing test and lower friction coefficient in the friction test, as compared with the TiAlN coating.

  2. The effects of visual control whole body vibration exercise on balance and gait function of stroke patients.

    PubMed

    Choi, Eon-Tak; Kim, Yong-Nam; Cho, Woon-Soo; Lee, Dong-Kyu

    2016-11-01

    [Purpose] This study aims to verify the effects of visual control whole body vibration exercise on balance and gait function of stroke patients. [Subjects and Methods] A total of 22 stroke patients were randomly assigned to two groups; 11 to the experimental group and 11 to the control group. Both groups received 30 minutes of Neuro-developmental treatment 5 times per week for 4 weeks. The experimental group additionally performed 10 minutes of visual control whole body vibration exercise 5 times per week during the 4 weeks. Balance was measured using the Functional Reach Test. Gait was measured using the Timed Up and Go Test. [Results] An in-group comparison in the experimental group showed significant differences in the Functional Reach Test and Timed Up and Go Test. In comparing the groups, the Functional Reach Test and Timed Up and Go Test of the experimental group were more significantly different compared to the control group. [Conclusion] These results suggest that visual control whole body vibration exercise has a positive effect on the balance and gait function of stroke patients.

  3. Security From Detection (Vehicles)

    DTIC Science & Technology

    2011-02-24

    Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps

  4. Security from Detection (Vehicles)

    DTIC Science & Technology

    2011-02-24

    Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps

  5. An automated data collection system for a Charpy impact tester

    NASA Technical Reports Server (NTRS)

    Weigman, Bernard J.; Spiegel, F. Xavier

    1993-01-01

    A method for automated data collection has been developed for a Charpy impact tester. A potentiometer is connected to the pivot point of the hammer and measures the angular displacement of the hammer. This data is collected with a computer and, through appropriate software, accurately records the energy absorbed by the specimen. The device can be easily calibrated with minimal effort.

  6. PH Tester Gauge Repeatability and Reproducibility Study for WO3 Nanostructure Hydrothermal Growth Process

    NASA Astrophysics Data System (ADS)

    Abd Rashid, Amirul; Hayati Saad, Nor; Bien Chia Sheng, Daniel; Yee, Lee Wai

    2014-06-01

    PH value is one of the important variables for tungsten trioxide (WO3) nanostructure hydrothermal synthesis process. The morphology of the synthesized nanostructure can be properly controlled by measuring and controlling the pH value of the solution used in this facile synthesis route. Therefore, it is very crucial to ensure the gauge used for pH measurement is reliable in order to achieve the expected result. In this study, gauge repeatability and reproducibility (GR&R) method was used to assess the repeatability and reproducibility of the pH tester. Based on ANOVA method, the design of experimental metrics as well as the result of the experiment was analyzed using Minitab software. It was found that the initial GR&R value for the tester was at 17.55 % which considered as acceptable. To further improve the GR&R level, a new pH measuring procedure was introduced. With the new procedure, the GR&R value was able to be reduced to 2.05%, which means the tester is statistically very ideal to measure the pH of the solution prepared for WO3 hydrothermal synthesis process.

  7. Combining ability of S3 progenies for key agronomic traits in popcorn: comparison of testers in top-crosses.

    PubMed

    de Lima, V J; do Amaral Junior, A T; Kamphorst, S H; Pena, G F; Leite, J T; Schmitt, K F M; Vittorazzi, C; de Almeida Filho, J E; Mora, F

    2016-12-02

    The successful development of hybrid cultivars depends on the reliability of estimated combining ability of the parent lines. The objectives of this study were to assess the combining ability of partially inbred S 3 families of popcorn derived from the open-pollinated variety UENF 14, via top-crosses with four testers, and to compare the testers for their ability to discriminate the S 3 progenies. The experiment was conducted in the 2015/2016 crop season, in an incomplete-block (Lattice) design with three replications. The following agronomic traits were evaluated: average plant height, grain yield (GY), popping expansion (PE), and expanded popcorn volume per hectare. The top-cross hybrid, originating from the BRS-Angela vs S 3 progeny 10 combination, was indicated as promising, showing high values for specific combining ability for GY and PE. For the S 3 progenies that showed high and positive GCA values for GY and PE, the continuity of the breeding program is recommended, with the advance of self-pollination generations. Fasoulas' differentiation index discriminated the BRS-Angela tester as the most suitable for identifying the superior progenies.

  8. Reliability and Concurrent Validity of Dynamic Rotator Stability Test-A Cross Sectional study.

    PubMed

    Binoy Mathew, K V; Eapen, Charu; Kumar, P Senthil

    2012-01-01

    To find intra rater and inter rater reliability of Dynamic Rotator Stability Test (DRST) and to find concurrent validity of Dynamic Rotator Stability Test (DRST) with University of Pennsylvania Shoulder Score (PENN) Scale. 40 subjects of either gender between the age group of 18-70 with painful shoulder conditions of musculoskeletal origin was selected through convenient sampling. Tester 1 and tester 2 administered DRST and PENN scale randomly. In a subgroup of 20 subjects DRST was administered by both the testers to find the inter rater reliability. 180° Standard Universal Goniometer was used to take measurements. For intra-rater reliability, all the test variables were showing highly significant correlation (p=.94 - 1). For inter -rater, with tester 2, test variables like position, ROM, force, direction of abnormal translation, pain during the test, compensatory movement during test were found to be significant (p=.71-1).only some variables of DRST showed significant correlation with PENN scale (P=.320-.450). Dynamic Rotator Stability Test has good intra rater and moderate inter rater reliability. Concurrent validity of Dynamic Rotator Stability Test was found to be poor when compared to PENN Shoulder Score.

  9. Functional visual fields: relationship of visual field areas to self-reported function.

    PubMed

    Subhi, Hikmat; Latham, Keziah; Myint, Joy; Crossland, Michael D

    2017-07-01

    The aim of this study is to relate areas of the visual field to functional difficulties to inform the development of a binocular visual field assessment that can reflect the functional consequences of visual field loss. Fifty-two participants with peripheral visual field loss undertook binocular assessment of visual fields using the 30-2 and 60-4 SITA Fast programs on the Humphrey Field Analyser, and mean thresholds were derived. Binocular visual acuity, contrast sensitivity and near reading performance were also determined. Self-reported overall and mobility function were assessed using the Dutch ICF Activity Inventory. Greater visual field loss (0-60°) was associated with worse self-reported function both overall (R 2 = 0.50; p < 0.0001), and for mobility (R 2 = 0.64; p < 0.0001). Central (0-30°) and peripheral (30-60°) visual field areas were similarly related to mobility function (R 2 = 0.61, p < 0.0001 and R 2 = 0.63, p < 0.0001 respectively), although the peripheral (30-60°) visual field was the best predictor of mobility self-reported function in multiple regression analyses. Superior and inferior visual field areas related similarly to mobility function (R 2 = 0.56, p < 0.0001 and R 2 = 0.67, p < 0.0001 respectively). The inferior field was found to be the best predictor of mobility function in multiple regression analysis. Mean threshold of the binocular visual field to 60° eccentricity is a good predictor of self-reported function overall, and particularly of mobility function. Both the central (0-30°) and peripheral (30-60°) mean threshold are good predictors of self-reported function, but the peripheral (30-0°) field is a slightly better predictor of mobility function, and should not be ignored when considering functional consequences of field loss. The inferior visual field is a slightly stronger predictor of perceived overall and mobility function than the superior field. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  10. Navy Mobility Fuels Evaluation.

    DTIC Science & Technology

    1984-07-20

    Test Results on di-Linoleic Acid in Isooctane ................................. 198 8.4.11 Comparison of Lucas and BOCM Test Results... acid ) required for monolayer coverage of the metal surfaces. TRW/Lucas Tester studies, applied to an investigation of corrosion inhibitors, demonstrate 1...not powerful lubricity enhancers. Compared to long chain organic acids they are about two orders of magnitude less effective. 12 ..... .. 39364-6006-UT

  11. A Cross-Sectional Behavioral Genetic Analysis of Task Persistence in the Transition to Middle Childhood

    ERIC Educational Resources Information Center

    Deater-Deckard, Kirby; Petrill, Stephen A.; Thompson, Lee A.; DeThorne, Laura S.

    2005-01-01

    Task persistence, measured by a composite score of independent teacher, tester and observer reports, was examined using behavioral genetic analysis. Participants included 92 monozygotic and 137 same-sex dizygotic twin pairs in Kindergarten or 1st grade (4.3 to 7.9 years old). Task persistence was widely distributed, higher among older children,…

  12. Mutagenicity study of weeds and common plants used in traditional medicine and for animal feed.

    PubMed

    Thepouyporn, Apanchanid; Kwanbunjan, Karunee; Pooudong, Somchai; Changbumrung, Supranee

    2006-01-01

    Mutagenicity and antimutagenicity potentials were tested using Ames' test in crude distilled water and absolute ethanol extracts from the stems and leaves of Peperomia pellucida (Linn.) Kunth, Eichhornia crassipes Solms, Colocasia esculenta Schott and Brachiaria mutica (Forssk.) Stapf, and the stems of Musa sapientum Linn. No mutagenic effect was found in any of the 10 mg/plate crude extracts of these plants for either TA98 or TA100 of Salmonella typhimurium, in a direct test and a mutagenic induced test by S-9 mix. Both distilled water and absolute ethanol extract of 0.5-10 mg/plate B. mutica showed strong antimutagenicity to AFB1, B(a)P and 4NQO in two tester strains. Ethanol extract of 0.1-0.5 mg/plate C. esculenta also showed antimutagenicity to AFB1, B(a)P and 4NQO in two tester strains, but the 0.5-10 mg/plate water extract had an antimutagenic effect only for B(a)P in TA98. The ethanol extracts of 5 mg/plate B. mutica and 0.5 mg/plate C. esculenta are cytotoxic, as indicated by their partial killing effect.

  13. The Blue Arc Entoptic Phenomenon in Glaucoma (An American Ophthalmological Thesis)

    PubMed Central

    Pasquale, Louis R.; Brusie, Steven

    2013-01-01

    Purpose: To determine whether the blue arc entoptic phenomenon, a positive visual response originating from the retina with a shape that conforms to the topology of the nerve fiber layer, is depressed in glaucoma. Methods: We recruited a cross-sectional, nonconsecutive sample of 202 patients from a single institution in a prospective manner. Subjects underwent full ophthalmic examination, including standard automated perimetry (Humphrey Visual Field 24–2) or frequency doubling technology (Screening C 20–5) perimetry. Eligible patients viewed computer-generated stimuli under conditions chosen to optimize perception of the blue arcs. Unmasked testers instructed patients to report whether they were able to perceive blue arcs but did not reveal what response was expected. We created multivariable logistic regression models to ascertain the demographic and clinical parameters associated with perceiving the blue arcs. Results: In multivariable analyses, each 0.1 unit increase in cup-disc ratio was associated with 36% reduced likelihood of perceiving the blue arcs (odds ratio [OR] = 0.66 [95% confidence interval (CI): 0.53–0.83], P<.001). A smaller mean defect was associated with an increased likelihood of perceiving the blue arcs (OR=1.79 [95% CI: 1.40–2.28]); P<.001), while larger pattern standard deviation (OR=0.72 [95% CI: 0.57–0.91]; P=.005) and abnormal glaucoma hemifield test (OR=0.25 [0.10–0.65]; P=.006) were associated with a reduced likelihood of perceiving them. Older age and media opacity were also associated with an inability to perceive the blue arcs. Conclusion: In this study, the inability to perceive the blue arcs correlated with structural and functional features associated with glaucoma, although older age and media opacity were also predictors of this entoptic response. PMID:24167324

  14. The blue arc entoptic phenomenon in glaucoma (an American ophthalmological thesis).

    PubMed

    Pasquale, Louis R; Brusie, Steven

    2013-09-01

    To determine whether the blue arc entoptic phenomenon, a positive visual response originating from the retina with a shape that conforms to the topology of the nerve fiber layer, is depressed in glaucoma. We recruited a cross-sectional, nonconsecutive sample of 202 patients from a single institution in a prospective manner. Subjects underwent full ophthalmic examination, including standard automated perimetry (Humphrey Visual Field 24-2) or frequency doubling technology (Screening C 20-5) perimetry. Eligible patients viewed computer-generated stimuli under conditions chosen to optimize perception of the blue arcs. Unmasked testers instructed patients to report whether they were able to perceive blue arcs but did not reveal what response was expected. We created multivariable logistic regression models to ascertain the demographic and clinical parameters associated with perceiving the blue arcs. In multivariable analyses, each 0.1 unit increase in cup-disc ratio was associated with 36% reduced likelihood of perceiving the blue arcs (odds ratio [OR] = 0.66 [95% confidence interval (CI): 0.53-0.83], P<.001). A smaller mean defect was associated with an increased likelihood of perceiving the blue arcs (OR=1.79 [95% CI: 1.40-2.28]); P<.001), while larger pattern standard deviation (OR=0.72 [95% CI: 0.57-0.91]; P=.005) and abnormal glaucoma hemifield test (OR=0.25 [0.10-0.65]; P=.006) were associated with a reduced likelihood of perceiving them. Older age and media opacity were also associated with an inability to perceive the blue arcs. In this study, the inability to perceive the blue arcs correlated with structural and functional features associated with glaucoma, although older age and media opacity were also predictors of this entoptic response.

  15. Effect of narcotic pain reliever on pulp tests in women.

    PubMed

    Kardelis, Anthony C; Meinberg, Trudy A; Sulte, Heather R; Gound, Tom G; Marx, David B; Reinhardt, Richard A

    2002-07-01

    The purpose of this study was to determine the effect of one dose of a common narcotic-based pain reliever (Vicodin) on a battery of oral sensitivity tests across time in women. Fifteen Caucasian women randomly were given an oral dose of 10 mg of hydrocodone/1000 mg of acetaminophen or placebo in a double-blind, cross-over design. At baseline (before drug) and after 2, 4, and 8 h each subject was evaluated for sensitivity thresholds with four tests around an experimental tooth: (a) electric pulp tester applied to exposed root; (b) electric pulp tester on adjacent mucosa; (c) increasing probe pressure (grams) on adjacent mucosa; and (d) decreasing cold probe (degrees C) on the exposed root. The outcomes of all tests were not statistically different between drug and placebo treatments at any time point (p > 0.05). These results suggest that a systemic dose of hydrocodone/acetaminophen has little impact on healthy pulp or mucosa sensitivity in women as measured by common diagnostic tests.

  16. Rational ideation and empiric validation of an innovative digital dermographic tester.

    PubMed

    Lembo, C; Patruno, C; Balato, N; Ayala, F; Balato, A; Lembo, S

    2018-04-01

    Dermographism is a condition characterized by a weal response to a combination of pressure and traction on skin surface, and its diagnosis is based on medical history, clinical criteria and provocation test. The Dermographic Tester ® , a pen-sized tool containing a spring-loaded blunt tip, is the most widely used instrument for the provocation test, and it exerts increasing pressures on the skin surface according to an arbitrary units (AU) scale. Analysing the mechanism of function and trying to convert the AUs to SI units (g/mm 2 ), we found that this instrument had some defects and limits that would compromise a true and repeatable quantification of the weal response threshold. Consequently, we decided to develop a new instrument, the Digital Dermographic Tester (DDT), which is engineered with an inside force sensor to implement features lacking in the current tools, in the hope of enhancing the precision of the provocation test. To validate the effectiveness and accuracy of the DDT. We tested the DDT on 213 participants purposely sampled to obtain three groups, each with a different pattern of reaction to mechanical stimuli. Based on anamnestic, diagnostic and symptomatic criteria, patients were divided into dermographic urticaria (DU), spontaneous urticaria (SU) and healthy control (HC) groups. The DDT was used to apply 12 levels of pressure to the skin surface, and a frequency distribution of positive reactions was displayed for each group. A force of 36-40 g/mm 2 appropriately differentiated physiological from pathological conditions with high sensitivity and specificity. The DDT was found to be capable of differentiating patients with DU patients from those with SU and from HCs, and was able to precisely identify the weal elicitation threshold. © 2017 British Association of Dermatologists.

  17. Visual impairment at baseline is associated with future poor physical functioning among middle-aged women: The Study of Women's Health Across the Nation, Michigan Site.

    PubMed

    Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie

    2017-02-01

    Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): -4.19, -1.42) and 4.26s longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: -3.30, -1.21) than those without impaired near vision. Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Visual Impairment at Baseline is Associated with Future Poor Physical Functioning Among Middle-Aged Women: The Study of Women's Health Across the Nation, Michigan site

    PubMed Central

    Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie

    2016-01-01

    Objectives Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. Study design In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. Main Outcome Measures At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Results Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): −4.19,−1.42) and 4.26 seconds longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: −3.30,−1.21) than those without impaired near vision. Conclusion Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. PMID:28041592

  19. Quantification of the Upper Extremity Motor Functions of Stroke Patients Using a Smart Nine-Hole Peg Tester

    PubMed Central

    Marik, Anikó Rita; Fazekas, Gábor

    2018-01-01

    This paper introduces a smart nine-hole peg tester (s-9HPT), which comprises a standard nine-hole peg test pegboard, but with light-emitting diodes (LEDs) next to each hole. The s-9HPT still supports the traditional nine-hole peg test operating mode, in which the order of the peg placement and removal can be freely chosen. Considering this, the s-9HPT was used in lab research to analyze the traditional procedure and possible new procedures. As this analysis required subjects with similar levels of dexterity, measurement data from 16 healthy subjects (seven females, nine males, 25–80 years old) were used. We consequently found that illuminating the LEDs in various patterns facilitated guided tests of diverse complexity levels. Next, to demonstrate the clinical application of the s-9HPT, the improvement in the hand dexterity of 12 hospitalized stroke patients (45–80 years old, six females and six males) was monitored during their rehabilitation. Here, we used traditional and guided tests validated by healthy subjects. Consequently, improvements were found to be patient specific. At the beginning of rehabilitation, traditional tests suitably indicate improvements, while guided tests are beneficial following improvements in motor functions. Further, the guided tests motivated certain patients, meaning the rehabilitation was more effective for these individuals. PMID:29850001

  20. Evaluation of Next-Generation Vision Testers for Aeromedical Certification of Aviation Personnel

    DTIC Science & Technology

    2009-07-01

    measure distant, intermediate, and near acuity. The slides are essentially abbreviated versions of the Early Treatment for Diabetic Retinopathy Study...over, requiring intermediate vision testing and 12 were color deficient. Analysis was designed to detect statistically significant differences between...Vertical Phoria (Right & Left Hyperphoria) Test scores from each of the vision testers were collated and analyzed. Analysis was designed to detect

  1. NASA five-ball fatigue tester: Over 20 years of research

    NASA Technical Reports Server (NTRS)

    Zaretsky, E. V.; Parker, R. J.; Anderson, W. J.

    1981-01-01

    Studies were conducted to determine the effect on rolling-element fatigue life of contact angle, material hardness, chemistry, heat treatment and processing, lubricant type and chemistry, elastohydrodynamic film thickness, deformation and wear, vacuum, and temperature as well as Hertzian and residual stresses. Correlation was established between the results obtained using the five-ball tester and those obtained with full scale rolling-element bearings.

  2. Development of a preference-based index from the National Eye Institute Visual Function Questionnaire-25.

    PubMed

    Rentz, Anne M; Kowalski, Jonathan W; Walt, John G; Hays, Ron D; Brazier, John E; Yu, Ren; Lee, Paul; Bressler, Neil; Revicki, Dennis A

    2014-03-01

    Understanding how individuals value health states is central to patient-centered care and to health policy decision making. Generic preference-based measures of health may not effectively capture the impact of ocular diseases. Recently, 6 items from the National Eye Institute Visual Function Questionnaire-25 were used to develop the Visual Function Questionnaire-Utility Index health state classification, which defines visual function health states. To describe elicitation of preferences for health states generated from the Visual Function Questionnaire-Utility Index health state classification and development of an algorithm to estimate health preference scores for any health state. Nonintervention, cross-sectional study of the general community in 4 countries (Australia, Canada, United Kingdom, and United States). A total of 607 adult participants were recruited from local newspaper advertisements. In the United Kingdom, an existing database of participants from previous studies was used for recruitment. Eight of 15,625 possible health states from the Visual Function Questionnaire-Utility Index were valued using time trade-off technique. A θ severity score was calculated for Visual Function Questionnaire-Utility Index-defined health states using item response theory analysis. Regression models were then used to develop an algorithm to assign health state preference values for all potential health states defined by the Visual Function Questionnaire-Utility Index. Health state preference values for the 8 states ranged from a mean (SD) of 0.343 (0.395) to 0.956 (0.124). As expected, preference values declined with worsening visual function. Results indicate that the Visual Function Questionnaire-Utility Index describes states that participants view as spanning most of the continuum from full health to dead. Visual Function Questionnaire-Utility Index health state classification produces health preference scores that can be estimated in vision-related studies that include the National Eye Institute Visual Function Questionnaire-25. These preference scores may be of value for estimating utilities in economic and health policy analyses.

  3. Media/Device Configurations for Platoon Leader Tactical Training

    DTIC Science & Technology

    1985-02-01

    munication and visual communication sig- na ls, VInputs to the The device should simulate the real- Platoon Leader time receipt of all tactical voice...communication, audio and visual battle- field cues, and visual communication signals. 14- Table 4 (Continued) Functional Capability Categories and...battlefield cues, and visual communication signals. 0.8 Receipt of limited tactical voice communication, plus audio and visual battlefield cues, and visual

  4. A new peer instruction method for teaching practical skills in the health sciences: an evaluation of the 'Learning Trail'.

    PubMed

    Dollman, James

    2005-01-01

    The 'Learning Trail' is an innovative application of peer-mediated instruction designed to enhance student learning in large practical classes. The strategy specifically seeks to improve participants' attention to details of protocol that are often difficult to observe during teacher-centered demonstrations to large groups. Students (n=68) at the University of South Australia trialed this strategy, in which instruction in anthropometric techniques is initiated by an instructor to a group of 3-4 students and then sent in 'waves' from one student group to the next. The final group in the sequence demonstrates the techniques to the instructor, who notes any departures from technical accuracy. As each technical module is flowing from group to group, the instructor initiates the next 'wave' with the first group, and the process is repeated until all of the relevant skills are processed. The final stage is a full class discussion during which sources of technical error are identified and resolved. In this trial, students taught skinfold measurement by the peer instructed method (PI; n=33) were compared with a traditionally instructed group (TI; n=35), in which the instructor was responsible for all information transfer. For each participant, technical errors of measurement (TEM) were calculated; the intra-tester TEM as a measure of reliability, and the inter-tester TEM, in which the student's measures are compared with those of a criterion anthropometrist to give an indication of validity. There were no differences between TI and PI groups on intra-tester TEM (p=0.24), but the PI group had a lower inter-tester TEM for pooled skinfold sites (p=0.006) and for one individual site (triceps; p=0.007), but not the other three sites. The time taken to complete the whole set of instructions did not differ between delivery modes. The results of this trial suggest that the peer-mediated strategy may be more effective than teacher-centered instruction in terms of technical accuracy in anthropometry.

  5. Comparative Evaluation of Flow Quantification across the Atrioventricular Valve in Patients with Functional Univentricular Heart after Fontan's Surgery and Healthy Controls: Measurement by 4D Flow Magnetic Resonance Imaging and Streamline Visualization.

    PubMed

    She, Hoi Lam; Roest, Arno A W; Calkoen, Emmeline E; van den Boogaard, Pieter J; van der Geest, Rob J; Hazekamp, Mark G; de Roos, Albert; Westenberg, Jos J M

    2017-01-01

    To evaluate the inflow pattern and flow quantification in patients with functional univentricular heart after Fontan's operation using 4D flow magnetic resonance imaging (MRI) with streamline visualization when compared with the conventional 2D flow approach. Seven patients with functional univentricular heart after Fontan's operation and twenty-three healthy controls underwent 4D flow MRI. In two orthogonal two-chamber planes, streamline visualization was applied, and inflow angles with peak inflow velocity (PIV) were measured. Transatrioventricular flow quantification was assessed using conventional 2D multiplanar reformation (MPR) and 4D MPR tracking the annulus and perpendicular to the streamline inflow at PIV, and they were validated with net forward aortic flow. Inflow angles at PIV in the patient group demonstrated wide variation of angles and directions when compared with the control group (P < .01). The use of 4D flow MRI with streamlines visualization in quantification of the transatrioventricular flow had smaller limits of agreement (2.2 ± 4.1 mL; 95% limit of agreement -5.9-10.3 mL) when compared with the static plane assessment from 2DFlow MRI (-2.2 ± 18.5 mL; 95% limit of agreement agreement -38.5-34.1 mL). Stronger correlation was present in the 4D flow between the aortic and trans-atrioventricular flow (R 2 correlation in 4D flow: 0.893; in 2D flow: 0.786). Streamline visualization in 4D flow MRI confirmed variable atrioventricular inflow directions in patients with functional univentricular heart with previous Fontan's procedure. 4D flow aided generation of measurement planes according to the blood flood dynamics and has proven to be more accurate than the fixed plane 2D flow measurements when calculating flow quantifications. © 2016 Wiley Periodicals, Inc.

  6. Evaluation of composite wear with a new multi-mode oral wear simulator.

    PubMed

    Condon, J R; Ferracane, J L

    1996-07-01

    The goals of this study were to develop a machine which simultaneously produces wear through the two main oral wear mechanisms of abrasion and attrition by the action of an enamel antagonist and to compare the results obtained for dental composites using this machine to those obtained from clinical studies and other in vitro studies. The accuracy of this new wear tester was determined by examining 11 commercial composite filling materials and 1 amalgam. Specimens were subjected to three-body abrasion and attrition wear for 50,000 cycles. Profilometry was used to quantitate wear of the composites. Linear regression analysis was used to correlate the results to those obtained from clinical studies, as well as from other in vitro wear testers. The area of enamel wear was also determined by image analysis. The SEM was used to evaluate the wear surfaces. The lowest abrasion wear was recorded for the amalgam and for the microfill and smaller-particle composites. Attrition wear was enhanced for the microfill composites and one small-particle hybrid. There was a strong correlation between the results obtained with the new wear tester and those obtained in the clinical trials cited in the literature. Wear of the enamel antagonist was the greatest for the composites with the largest particle sizes. The wear tester showed a reasonable correlation with other wear-producing machines. A new wear tester developed to evaluate and discriminate abrasion and attrition wear provided results similar to those reported in the literature for a variety of commercial composites. The new machine is capable of characterizing the behavior of a material in multiple wear modes simultaneously with one simple, realistic test.

  7. Computational Fluid Dynamics Analysis of the Venturi Dustiness Tester

    PubMed Central

    Dubey, Prahit; Ghia, Urmila; Turkevich, Leonid A.

    2017-01-01

    Dustiness quantifies the propensity of a finely divided solid to be aerosolized by a prescribed mechanical stimulus. Dustiness is relevant wherever powders are mixed, transferred or handled, and is important in the control of hazardous exposures and the prevention of dust explosions and product loss. Limited quantities of active pharmaceutical powders available for testing led to the development (at University of North Carolina) of a Venturi-driven dustiness tester. The powder is turbulently injected at high speed (Re ~ 2 × 104) into a glass chamber; the aerosol is then gently sampled (Re ~ 2 × 103) through two filters located at the top of the chamber; the dustiness index is the ratio of sampled to injected mass of powder. Injection is activated by suction at an Extraction Port at the top of the chamber; loss of powder during injection compromises the sampled dustiness. The present work analyzes the flow inside the Venturi Dustiness Tester, using an Unsteady Reynolds-Averaged Navier-Stokes formulation with the k-ω Shear Stress Transport turbulence model. The simulation considers single-phase flow, valid for small particles (Stokes number Stk <1). Results show that ~ 24% of fluid-tracers escape the tester before the Sampling Phase begins. Dispersion of the powder during the Injection Phase results in a uniform aerosol inside the tester, even for inhomogeneous injections, satisfying a necessary condition for the accurate evaluation of dustiness. Simulations are also performed under the conditions of reduced Extraction-Port flow; results confirm the importance of high Extraction-Port flow rate (standard operation) for uniform distribution of fluid tracers. Simulations are also performed under the conditions of delayed powder injection; results show that a uniform aerosol is still achieved provided 0.5 s elapses between powder injection and sampling. PMID:28638167

  8. Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers

    PubMed Central

    Baykal, D.; Siskey, R.S.; Haider, H.; Saikko, V.; Ahlroos, T.; Kurtz, S.M.

    2013-01-01

    The introduction of numerous formulations of Ultra-high molecular weight polyethylene (UHMWPE), which is widely used as a bearing material in orthopedic implants, necessitated screening of bearing couples to identify promising iterations for expensive joint simulations. Pin-on-disk (POD) testers capable of multidirectional sliding can correctly rank formulations of UHMWPE with respect to their predictive in vivo wear behavior. However, there are still uncertainties regarding POD test parameters for facilitating clinically relevant wear mechanisms of UHMWPE. Studies on the development of POD testing were briefly summarized. We systematically reviewed wear rate data of UHMWPE generated by POD testers. To determine if POD testing was capable of correctly ranking bearings and if test parameters outlined in ASTM F732 enabled differentiation between wear behavior of various formulations, mean wear rates of non-irradiated, conventional (25–50 kGy) and highly crosslinked (≥90 kGy) UHMWPE were grouped and compared. The mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 7.03, 5.39 and 0.67 mm3/MC. Based on studies that complied with the guidelines of ASTM F732, the mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 0.32, 0.21 and 0.04 mm3/km, respectively. In both sets of results, the mean wear rate of highly crosslinked UHMPWE was smaller than both conventional and non-irradiated UHMWPEs (p<0.05). Thus, POD testers can compare highly crosslinked and conventional UHMWPEs despite different test parameters. Narrowing the allowable range for standardized test parameters could improve sensitivity of multi-axial testers in correctly ranking materials. PMID:23831149

  9. Quality of life in patients with visual impairment in Ibadan: a clinical study in primary care.

    PubMed

    Adigun, Kehinde; Oluleye, Tunji S; Ladipo, Modupe Ma; Olowookere, Samuel Anu

    2014-01-01

    Visual function is important for optimal orientation in functional and social life, and has an effect on physical and emotional well-being. Visual impairment, therefore, leads to restrictions in all aspects of daily living and is related to quality of life. The aim of this study was to provide information on the causes of visual impairment in patients presenting to their family physician, the spectrum of impairment, and its impact on quality of life for these patients. This descriptive cross-sectional study of 375 adult patients with ocular symptoms was performed in the general outpatient department of the University College Hospital, Ibadan, from July to September, 2009. After checking their presenting visual acuity, the patients were interviewed using the Vision-Related Quality of Life questionnaire to determine the impact of visual impairment on their quality of life. Ophthalmic examinations were performed to determine the causes of visual impairment. The results were analyzed using proportions and percentages. The main causes of visual impairment were cataracts (58.7%), refractive error (19.4%), and glaucoma (2.9%). Visual impairment was found to be associated with advancing age, low education, and unemployment (P<0.001). Most patients (85.1%) were found to have good quality of life overall. Quality of life was found to be poor in the domains of visual function (64.2%) and social interaction (50.9%). Quality of life was found to be related to the degree of visual impairment, ie, blind patients reported poor quality of life (41.4%) when compared with those having low vision (8.6%) or near normal vision (2.4%, P<0.001). This study identified poor quality of life in patients with a higher degree of visual impairment. Family physicians need to identify these visually impaired patients early and make timely referrals.

  10. White balance tester with color sensor for industrial applications

    NASA Astrophysics Data System (ADS)

    Chen, Jiasheng; Zhu, XiaoSong

    1996-12-01

    The white balance tester is an instrument that adjusts the white balance for color TVs, monitors, and PC displays. We have designed a new white balance tester for use directly at the production line. It picks up the R (Red), G (Green), and B (Blue) signals for the screen using color sensors, compares the signals with the data previously stored in the internal memory, displays their differences with LED bars in the compare mode or displays x y Y, u v Y, JND (just noticeable difference) as well as correlated color temperature in the numerical mode. A built-in TV signal generator sets the luminance of the adjusting screen to the brightness of the reference white screen automatically. A 16-bit single chip microcomputer processes the measured values and controls the output levels of the TV signal generator.

  11. Long-term outcomes of gene therapy for the treatment of Leber's hereditary optic neuropathy.

    PubMed

    Yang, Shuo; Ma, Si-Qi; Wan, Xing; He, Heng; Pei, Han; Zhao, Min-Jian; Chen, Chen; Wang, Dao-Wen; Dong, Xiao-Yan; Yuan, Jia-Jia; Li, Bin

    2016-08-01

    Leber's hereditary optic neuropathy (LHON) is a disease that leads to blindness. Gene therapy has been investigated with some success, and could lead to important advancements in treating LHON. This was a prospective, open-label trial involving 9 LHON patients at Tongji Hospital, Wuhan, China, from August 2011 to December 2015. The purpose of this study was to evaluate the long-term outcomes of gene therapy for LHON. Nine LHON patients voluntarily received an intravitreal injection of rAAV2-ND4. Systemic examinations and visual function tests were performed during the 36-month follow-up period to determine the safety and efficacy of this gene therapy. Based on successful experiments in an animal model of LHON, 1 subject also received an rAAV2-ND4 injection in the second eye 12months after gene therapy was administered in the first eye. Recovery of visual acuity was defined as the primary outcome of this study. Changes in the visual field, visual evoked potential (VEP), optical coherence tomography findings, liver and kidney function, and antibodies against AAV2 were defined as secondary endpoints. Eight patients (Patients 2-9) received unilateral gene therapy and visual function improvement was observed in both treated eyes (Patients 4, 6, 7, and 8) and untreated eyes (Patients 2, 3, 4, 6 and 8). Visual regression fluctuations, defined as changes in visual acuity greater than or equal to 0.3 logMAR, were observed in Patients 2 and 9. Age at disease onset, disease duration, and the amount of remaining optic nerve fibers did not have a significant effect on the visual function improvement. The visual field and pattern reversal VEP also improved. The patient (Patient 1) who received gene therapy in both eyes had improved visual acuity in the injected eye after the first treatment. Unfortunately, visual acuity in this eye decreased 3months after he received gene therapy in the second eye. Animal experiments suggested that ND4 expression remains stable in the contralateral eye after intravitreal injections. No serious safety problem was observed in the 3-year follow-up of the 9 participants enrolled in this virus-based gene therapy. Meanwhile, our results support the use of intravitreal rAAV2-ND4 as an aggressive maneuver in our clinical trial. Further study in additional patients and in these 9 subjects is needed to better understand the effects of rAAV2-ND4 gene therapy on LHON and to increase the applications of this technique. Copyright © 2016 The Ohio State University Wexner Medical Center. Published by Elsevier B.V. All rights reserved.

  12. Genetic Analysis of Haploids from Industrial Strains of Baker's Yeast

    PubMed Central

    Oda, Yuji; Ouchi, Kozo

    1989-01-01

    Strains of baker's yeast conventionally used by the baking industry in Japan were tested for the ability to sporulate and produce viable haploid spores. Three isolates which possessed the properties of baker's yeasts were obtained from single spores. Each strain was a haploid, and one of these strains, YOY34, was characterized. YOY34 fermented maltose and sucrose, but did not utilize galactose, unlike its parental strain. Genetic analysis showed that YOY34 carried two MAL genes, one functional and one cryptic; two SUC genes; and one defective gal gene. The genotype of YOY34 was identified as MATα MAL1 MAL3g SUC2 SUC4 gall. The MAL1 gene from this haploid was constitutively expressed, was dominant over other wild-type MAL tester genes, and gave a weak sucrose fermentation. YOY34 was suitable for both bakery products, like conventional baker's yeasts, and for genetic analysis, like laboratory strains. PMID:16347967

  13. Procurement specifications report. IMBLS phase B-4

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Procurement specifications to provide vendors of space systems with supporting information to accurately price the selected major buy items are illustrated. In performing this task, rigid constraints on specifications and drawing details are avoided beyond those necessary to define basic requirements. Described are digital processing equipment, mass spectrometer, body mass measuring device, sensors, bio-belt power source, vision tester and instrumentation for a biochemical station.

  14. Evaluation of bearing configurations using the single bearing tester in liquid nitrogen

    NASA Technical Reports Server (NTRS)

    Jett, T.; Hall, P.; Thom, R.

    1991-01-01

    Various bearing configurations were tested using the Marshall Space Flight Center single bearing tester with LN2 as the cryogenic coolant. The baseline was one Rocketdyne phase one high pressure oxidizer turbopump (HPOTP) pump end 45-mm bore bearing. The bearing configurations that were tested included a Salox/M cage configuration, a silicon nitride ball configuration, an elongated cage configuration, and a Bray 601 grease configuration.

  15. Capabilities in Context: Evaluating the Net-Centric Enterprise

    DTIC Science & Technology

    2009-03-01

    with an intuitive keyword search using the enterprise’s federated search capability. Service accessibility. Testers will ensure that local service has...search using the enterprise’s federated search capability. Data accessibility. Testers will ensure that Feder- ated Search results provide active link...user may request access to the data, and be available within ‘‘2 clicks’’ from the active link provided by Federated Search . Data understandability

  16. Repeatability of three-dimensional thorax and pelvis kinematics in the golf swing measured using a field-based motion capture system.

    PubMed

    Evans, Kerrie; Horan, Sean A; Neal, Robert J; Barrett, Rod S; Mills, Peter M

    2012-06-01

    Field-based methods of evaluating three-dimensional (3D) swing kinematics offer coaches and researchers the opportunity to assess golfers in context-specific environments. The purpose of this study was to establish the inter-trial, between-tester, between-location, and between-day repeatability of thorax and pelvis kinematics during the downswing using an electromagnetic motion capture system. Two experienced testers measured swing kinematics in 20 golfers (handicap < or =14 strokes) on consecutive days in an indoor and outdoor location. Participants performed five swings with each of two clubs (five-iron and driver) at each test condition. Repeatability of 3D kinematic data was evaluated by computing the coefficient of multiple determination (CMD) and the systematic error (SE). With the exception of pelvis forward bend for between-day and between-tester conditions, CMDs exceeded 0.854 for all variables, indicating high levels of overall waveform repeatability across conditions. When repeatability was compared across conditions using MANOVA, the lowest CMDs and highest SEs were found for the between-tester and between-day conditions. The highest CMDs were for the inter-trial and between-location conditions. The absence of significant differences in CMDs between these two conditions supports this method of analysing pelvis and thorax kinematics in different environmental settings without unduly affecting repeatability.

  17. The design and analysis of single flank transmission error tester for loaded gears

    NASA Technical Reports Server (NTRS)

    Bassett, Duane E.; Houser, Donald R.

    1987-01-01

    To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement.

  18. Effect of Cellular Mobile Phone Use and Cetrizine on Hand-Eye Coordination and Visual Acuity.

    PubMed

    Gawit, Kalpita Ganpat; Tiwari, Smita Anand; Kasabe, Gauri Hari; Deshpande, Pradeep Kisanrao; Ghongane, Balasaheb Baburao

    2017-09-01

    Cellular mobile phones are a major cause of distraction especially while driving. The aggressive and inappropriate use of cellular mobile phones has increased the risk of accidents. Similar alerts are available in literature for certain substances and drugs (e.g. second generation anti H1 drug -Cetirizine) which also derange psychomotor performance and parameters of alertness. This study measured variations in hand-eye coordination and visual acuity due to use of cellular mobile phone in comparison to that of commonly used antihistaminic drug viz., single dose Cetirizine 10 mg. It was a single blind, single dose, interventional study, 100 healthy human volunteers divided into two groups. Baseline readings of all volunteers were noted. Group-I (n=50) was Cetirizine group (10mg orally stat), Group -II (n=50) Cellular mobile phone user group. Alertness was tested on hand- steadiness tester (Reaction Time Index = RTI) and on Flicker-fusion apparatus (visual acuity - Critical Flicker Fusion Frequency per second= CFFF/sec). Baseline readings of all volunteers were noted before intervention. Baseline was compared with readings at three hour post-intervention and was analysed by paired t-test. Inter-group comparison of parameters was also done and was analysed by unpaired t-test. The baseline RTI (95.46±41.74, 85.11±39.05) and CFF low and high (40.07±9.970, 40.76±9.309 and 40.42±9.035, 40.48±9.863) respectively, in Cetirizine group and Mobile user group were comparable. The RTI increased significantly (116.4±51.46, 102.8±49.26) in both the groups after intervention. However, there is no significant change in CFF intensity from baseline in either group post-intervention. Concurrent use of mobile phone while performing tasks, showed significant impairment of hand-steadiness which was comparable to that produced by single dose Cetirizine 10 mg and this may be one of the factors contributing to their close association with road traffic accidents.

  19. Visual Cone Arrestin 4 Contributes to Visual Function and Cone Health.

    PubMed

    Deming, Janise D; Pak, Joseph S; Brown, Bruce M; Kim, Moon K; Aung, Moe H; Eom, Yun Sung; Shin, Jung-A; Lee, Eun-Jin; Pardue, Machelle T; Craft, Cheryl Mae

    2015-08-01

    Visual arrestins (ARR) play a critical role in shutoff of rod and cone phototransduction. When electrophysiological responses are measured for a single mouse cone photoreceptor, ARR1 expression can substitute for ARR4 in cone pigment desensitization; however, each arrestin may also contribute its own, unique role to modulate other cellular functions. A combination of ERG, optokinetic tracking, immunohistochemistry, and immunoblot analysis was used to investigate the retinal phenotypes of Arr4 null mice (Arr4-/-) compared with age-matched control, wild-type mice. When 2-month-old Arr4-/- mice were compared with wild-type mice, they had diminished visual acuity and contrast sensitivity, yet enhanced ERG flicker response and higher photopic ERG b-wave amplitudes. In contrast, in older Arr4-/- mice, all ERG amplitudes were significantly reduced in magnitude compared with age-matched controls. Furthermore, in older Arr4-/- mice, the total cone numbers decreased and cone opsin protein immunoreactive expression levels were significantly reduced, while overall photoreceptor outer nuclear layer thickness was unchanged. Our study demonstrates that Arr4-/- mice display distinct phenotypic differences when compared to controls, suggesting that ARR4 modulates essential functions in high acuity vision and downstream cellular signaling pathways that are not fulfilled or substituted by the coexpression of ARR1, despite its high expression levels in all mouse cones. Without normal ARR4 expression levels, cones slowly degenerate with increasing age, making this a new model to study age-related cone dystrophy.

  20. Correlation between visual function and refractive, topographic, pachymetric and aberrometric data in eyes with keratoconus

    PubMed Central

    Bayraktar Bilen, Neslihan; Hepsen, Ibrahim F.; Arce, Carlos G.

    2016-01-01

    AIM To analyze the relationship between two visual functions and refractive, topographic, pachymetric and aberrometric indicators in eyes with keratoconus. METHODS Corrected distance visual acuity (CDVA), and letter contrast sensitivity (CS) were correlated with refraction, corneal topography, pachymetry, and total corneal wavefront data prospectively in 71 eyes with keratoconus. The topographic indices assessed were simulated keratometry for the flattest and steepest meridians (SimK1 and SimK2), posterior steeper K (Ks), elevation value in best-fit sphere (BFS) maps, squared eccentricity (Є2), aspheric asymmetric index (AAI), pachymetry, thickness progression index (TPI), the amount of pachymetric decentralization (APD), and GalileiTM-keratoconus indices. RESULTS The mean CDVA (expressed as logMAR) were 0.25±0.21. The mean CS was 1.25±0.46. The spherical refraction correlated well with CDVA (r=-0.526, P<0.001). From topographic indices, SRI correlated with CS (r=-0.695), and IAI with CS (r=-0.672) (P<0.001 for all). Root mean square (RMS) was 4.3±1.81 µm, spherical aberration (SA) was -0.4±0.67 µm, vertical and horizontal coma were -2.1±1.47 and -0.4±0.72 µm. All wavefront data (except horizontal coma), AAI, Є2 and maximum BFS correlated significantly with the visual function (P≤0.001 for all). CONCLUSION In this study, CS is more affected than CDVA as a visual function. The quantity and quality of vision is significantly correlated with well-known and new topographic indices. There is not a significant correlation between visual function and pachymetric parameters. The significantly correlated indices can be used in staging keratoconus and to follow the outcome of a treatment. PMID:27588266

  1. Cone Photoreceptor Abnormalities Correlate with Vision Loss in Patients with Stargardt Disease

    PubMed Central

    Chen, Yingming; Ratnam, Kavitha; Sundquist, Sanna M.; Lujan, Brandon; Ayyagari, Radha; Gudiseva, V. Harini; Roorda, Austin

    2011-01-01

    Purpose. To study the relationship between macular cone structure, fundus autofluorescence (AF), and visual function in patients with Stargardt disease (STGD). Methods. High-resolution images of the macula were obtained with adaptive optics scanning laser ophthalmoscopy (AOSLO) and spectral domain optical coherence tomography in 12 patients with STGD and 27 age-matched healthy subjects. Measures of retinal structure and AF were correlated with visual function, including best-corrected visual acuity, color vision, kinetic and static perimetry, fundus-guided microperimetry, and full-field electroretinography. Mutation analysis of the ABCA4 gene was completed in all patients. Results. Patients were 15 to 55 years old, and visual acuity ranged from 20/25–20/320. Central scotomas were present in all patients, although the fovea was spared in three patients. The earliest cone spacing abnormalities were observed in regions of homogeneous AF, normal visual function, and normal outer retinal structure. Outer retinal structure and AF were most normal near the optic disc. Longitudinal studies showed progressive increases in AF followed by reduced AF associated with losses of visual sensitivity, outer retinal layers, and cones. At least one disease-causing mutation in the ABCA4 gene was identified in 11 of 12 patients studied; 1 of 12 patients showed no disease-causing ABCA4 mutations. Conclusions. AOSLO imaging demonstrated abnormal cone spacing in regions of abnormal fundus AF and reduced visual function. These findings provide support for a model of disease progression in which lipofuscin accumulation results in homogeneously increased AF with cone spacing abnormalities, followed by heterogeneously increased AF with cone loss, then reduced AF with cone and RPE cell death. (ClinicalTrials.gov number, NCT00254605.) PMID:21296825

  2. Analysis by gender and Visual Imagery Reactivity of conventional and imagery Rorschach.

    PubMed

    Yanovski, A; Menduke, H; Albertson, M G

    1995-06-01

    Examined here are the effects of gender and Visual Imagery Reactivity in 80 consecutively selected psychiatric outpatients. The participants were grouped by gender and by the amounts of responsiveness to preceding therapy work using imagery (Imagery Nonreactors and Reactors). In the group of Imagery Nonreactors were 13 men and 22 women, and in the Reactor group were 17 men and 28 women. Compared were the responses to standard Rorschach (Conventional condition) with visual associations to memory images of Rorschach inkblots (Imagery condition). Responses were scored using the Visual Imagery Reactivity (VIR) scoring system, a general, test-nonspecific scoring method. Nonparametric statistical analysis showed that critical indicators of Imagery Reactivity encoded as High Affect/Conflict score and its derivatives associated with sexual or bizarre content were not significantly associated with gender; neither was Neutral Content score which categorizes "non-Reactivity." These results support the notion that system's criteria of Visual Imagery Reactivity can be applied equally to both men and women for the classification of Imagery Reactors and Nonreactors. Discussed are also the speculative consequences of extending the tolerance range of significance levels for the interaction between Reactivity and sex above the customary limit of p < .05 in borderline cases. The results of such an analysis may imply a trend towards more rigid defensiveness under Imagery and toward lesser verbal productivity in response to either the Conventional or the Imagery task among women who are Nonreactors. In Reactors, men produced significantly more Sexual Reference scores (in the subcategory not associated with High Affect/Conflict) than women, but this could be attributed to the effect of tester's and subjects' gender combined.

  3. Programmable Low-Voltage Circuit Breaker and Tester

    NASA Technical Reports Server (NTRS)

    Greenfield, Terry

    2008-01-01

    An instrumentation system that would comprise a remotely controllable and programmable low-voltage circuit breaker plus several electric-circuit-testing subsystems has been conceived, originally for use aboard a spacecraft during all phases of operation from pre-launch testing through launch, ascent, orbit, descent, and landing. The system could also be adapted to similar use aboard aircraft. In comparison with remotely controllable circuit breakers heretofore commercially available, this system would be smaller, less massive, and capable of performing more functions, as needed for aerospace applications.

  4. Online Cable Tester and Rerouter

    NASA Technical Reports Server (NTRS)

    Lewis, Mark; Medelius, Pedro

    2012-01-01

    Hardware and algorithms have been developed to transfer electrical power and data connectivity safely, efficiently, and automatically from an identified damaged/defective wire in a cable to an alternate wire path. The combination of online cable testing capabilities, along with intelligent signal rerouting algorithms, allows the user to overcome the inherent difficulty of maintaining system integrity and configuration control, while autonomously rerouting signals and functions without introducing new failure modes. The incorporation of this capability will increase the reliability of systems by ensuring system availability during operations.

  5. The combined effect of visual impairment and cognitive impairment on disability in older people.

    PubMed

    Whitson, Heather E; Cousins, Scott W; Burchett, Bruce M; Hybels, Celia F; Pieper, Carl F; Cohen, Harvey J

    2007-06-01

    To determine the risk of disability in individuals with coexisting visual and cognitive impairment and to compare the magnitude of risk associated with visual impairment, cognitive impairment, or the multimorbidity. Prospective cohort. North Carolina. Three thousand eight hundred seventy-eight participants in the North Carolina Established Populations for the Epidemiologic Studies of the Elderly with nonmissing visual status, cognitive status, and disability status data at baseline Short Portable Mental Status Questionnaire (cognitive impairment defined as > or =4 errors), self reported visual acuity (visual impairment defined as inability to see well enough to recognize a friend across the street or to read newspaper print), demographic and health-related variables, disability status (activities of daily living (ADLs), instrumental activities of daily living (IADLs), mobility), death, and time to nursing home placement. Participants with coexisting visual and cognitive impairment were at greater risk of IADL disability (odds ratio (OR)=6.50, 95% confidence interval (CI)=4.34-9.75), mobility disability (OR=4.04, 95% CI=2.49-6.54), ADL disability (OR=2.84, 95% CI=1.87-4.32), and incident ADL disability (OR=3.66, 95%, CI=2.36-5.65). In each case, the estimated OR associated with the multimorbidity was greater than the estimated OR associated with visual or cognitive impairment alone, a pattern that was not observed for other adverse outcomes assessed. No significant interactions were observed between cognitive impairment and visual impairment as predictors of disability status. Individuals with coexisting visual impairment and cognitive impairment are at high risk of disability, with each condition contributing additively to disability risk. Further study is needed to improve functional trajectories in patients with this prevalent multimorbidity. When visual or cognitive impairment is present, efforts to maximize the other function may be beneficial.

  6. Visual functions of commercial drivers in relation to road accidents in Nigeria

    PubMed Central

    Oladehinde, M. K.; Adeoye, A. O.; Adegbehingbe, B. O.; Onakoya, A. O.

    2007-01-01

    Objective: To determine the effects of the visual functions on the occurrence of road traffic accidents (RTA) amongst commercial drivers in Ife central local government area (LGA) of Osun state of Nigeria. Design: A cross-sectional study. Settings: Four major motor parks located at Ife Central LGA. Materials and Methods: Of the estimated 270 commercial drivers in the four major parks of the LGA, 215 consecutive drivers were interviewed and had their eyes examined. Structured questionnaires were administered by an ophthalmologist. Results: The prevalence of visual impairment (visual acuity < 6/18) in the better eye without correction was 3.3% ± 2.4 and there was a significant association between uncorrected visual acuity impairment in the better eye and RTA (P = 0.0152). Refractive error was seen in 8.4% of the drivers, but none of these wear corrective glasses. Visual field defect, abnormal stereopsis and color vision impairment did not have any significant association with RTA. Conclusion: Poor visual acuity is strongly associated with RTA amongst Nigerian commercial drivers as opposed to visual field defect, abnormal color vision and stereopsis. A significant proportion of visual impairment was due to uncorrected refractive errors. PMID:21938219

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, Michael J.

    The Hydrogen Fracture Toughness Tester (HFTT) is a mechanical testing machine designed for conducting fracture mechanics tests on materials in high-pressure hydrogen gas. The tester is needed for evaluating the effects of hydrogen on the cracking properties of tritium reservoir materials. It consists of an Instron Model 8862 Electromechanical Test Frame; an Autoclave Engineering Pressure Vessel, an Electric Potential Drop Crack Length Measurement System, associated computer control and data acquisition systems, and a high-pressure hydrogen gas manifold and handling system.

  8. Tester Detects Steady-Short Or Intermittent-Open Circuits

    NASA Technical Reports Server (NTRS)

    Anderson, Bobby L.

    1990-01-01

    Momentary open circuits or steady short circuits trigger buzzer. Simple, portable, lightweight testing circuit sounds long-duration alarm when it detects steady short circuit or momentary open circuit in coaxial cable or other two-conductor transmission line. Tester sensitive to discontinuities lasting 10 microseconds or longer. Used extensively for detecting intermittent open shorts in accelerometer and extensometer cables. Also used as ordinary buzzer-type continuity checker to detect steady short or open circuits.

  9. Review of LOX Bearing and Seal Materials Tester (BSMT) radial load system

    NASA Technical Reports Server (NTRS)

    Dufrane, K. F.; Kannel, J. W.

    1984-01-01

    Problems concerning the bearings in the high pressure oxygen turbopumps (HPOTP) were investigated. The tasks involved: failure analyses, bearing dynamics calculations, lubrication studies, wear studies, and analyses of thermal transients. The radial load system on MSFC's bearing and seal tester used to study components for the HPOTP in liquid oxygen (LOX) is analyzed and the wear behavior of AISI 440C steel with polytetrafluoroethylene (PTFE) lubrication is studied.

  10. A Portable Sorption Tester for Nondestructive Testing of Chemical Protective Garments

    DTIC Science & Technology

    1992-08-01

    ö.^ TECHNICAL REPORT NATICK/TR-92/042 Ap AASL MI A PORTABLE SORPTION TESTER FOR NONDESTRUCTIVE TESTING OF CHEMICAL PROTECTIVE GARMENTS ...items. DESTRUCTION NOTICE For Classified Documents: Follow the procedures in DoD 5200.22-M, Industrial Security Manual, Section 11-19 or DoD...disclosure of contents or reconstruction of the document. REPORT DOCUMENTATION PAGE Form Approved OMB No . 0704-0188 Public ’»oor.ra Ouro«" ":> -n

  11. Tester Independent Support Software System (TISSS)

    DTIC Science & Technology

    1991-08-01

    AD-A240 668 RL-TR-91-163 Final Technical Report August 1991 TESTER INDEPENDENT SUPPORT SOFTWARE SYSTEM (TISSS) Harris Corporation Dr. Robert Rolfe...Laboratory Air Force Systems Command Griffiss Air Force Base, NY 13441-5700 9_1 9 17 o15 This report has been reviewed by the Rome Laboratory Public...will assist us in maintaining a current mailing list. Do not return copies of this report unless contractual obligations or notices on a specific

  12. Non-Intrusive Impedance-Based Cable Tester

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.

  13. The I-V Measurement System for Solar Cells Based on MCU

    NASA Astrophysics Data System (ADS)

    Fengxiang, Chen; Yu, Ai; Jiafu, Wang; Lisheng, Wang

    2011-02-01

    In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts—data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.

  14. Research on Microstructure and Properties of Welded Joint of High Strength Steel

    NASA Astrophysics Data System (ADS)

    Zhu, Pengxiao; Li, Yi; Chen, Bo; Ma, Xuejiao; Zhang, Dongya; Tang, Cai

    2018-01-01

    BS960 steel plates were welded by Laser-MAG and MAG. The microstructure and properties of the welded joints were investigated by optical microscope, micro-hardness tester, universal tensile testing machine, impact tester, scanning electron microscope (SEM) and fatigue tester. By a series of experiments, the following results were obtained: The grain size of the coarse grain zone with Laser-MAG welded joint is 20μm, and that with MAG welded joint is about 32μm, both of the fine grain region are composed of fine lath martensite and granular bainite; the width of the heat affected region with Laser-MAG is lower than that with MAG. The strength and impact energy of welded joints with Laser-MAG is higher than that with MAG. The conditioned fatigue limit of welded joint with Laser-MAG is 280MPa; however, the conditioned fatigue limit of welded joint with MAG is 250MPa.

  15. 38 CFR 4.78 - Muscle function.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Evaluation of muscle function. (1) An evaluation for diplopia will be assigned to only one eye. When a... visual acuity for the poorer eye (or the affected eye, if disability of only one eye is service-connected... visual acuity for the poorer eye (or the affected eye, if disability of only one eye is service-connected...

  16. 38 CFR 4.78 - Muscle function.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Evaluation of muscle function. (1) An evaluation for diplopia will be assigned to only one eye. When a... visual acuity for the poorer eye (or the affected eye, if disability of only one eye is service-connected... visual acuity for the poorer eye (or the affected eye, if disability of only one eye is service-connected...

  17. Visual function at altitude under night vision assisted conditions.

    PubMed

    Vecchi, Diego; Morgagni, Fabio; Guadagno, Anton G; Lucertini, Marco

    2014-01-01

    Hypoxia, even mild, is known to produce negative effects on visual function, including decreased visual acuity and sensitivity to contrast, mostly in low light. This is of special concern when night vision devices (NVDs) are used during flight because they also provide poor images in terms of resolution and contrast. While wearing NVDs in low light conditions, 16 healthy male aviators were exposed to a simulated altitude of 12,500 ft in a hypobaric chamber. Snellen visual acuity decreased in normal light from 28.5 +/- 4.2/20 (normoxia) to 37.2 +/- 7.4/20 (hypoxia) and, in low light, from 33.8 +/- 6.1/20 (normoxia) to 42.2 +/- 8.4/20 (hypoxia), both at a significant level. An association was found between blood oxygen saturation and visual acuity without significance. No changes occurred in terms of sensitivity to contrast. Our data demonstrate that mild hypoxia is capable of affecting visual acuity and the photopic/high mesopic range of NVD-aided vision. This may be due to several reasons, including the sensitivity to hypoxia of photoreceptors and other retinal cells. Contrast sensitivity is possibly preserved under NVD-aided vision due to its dependency on the goggles' gain.

  18. Visual function and color vision in adults with Attention-Deficit/Hyperactivity Disorder.

    PubMed

    Kim, Soyeon; Chen, Samantha; Tannock, Rosemary

    2014-01-01

    Color vision and self-reported visual function in everyday life in young adults with Attention-Deficit/Hyperactivity Disorder (ADHD) were investigated. Participants were 30 young adults with ADHD and 30 controls matched for age and gender. They were tested individually and completed the Visual Activities Questionnaire (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) and A Quick Test of Cognitive Speed (AQT). The ADHD group reported significantly more problems in 4 of 8 areas on the VAQ: depth perception, peripheral vision, visual search and visual processing speed. Further analyses of VAQ items revealed that the ADHD group endorsed more visual problems associated with driving than controls. Color perception difficulties on the FMT were restricted to the blue spectrum in the ADHD group. FMT and AQT results revealed slower processing of visual stimuli in the ADHD group. A comprehensive investigation of mechanisms underlying visual function and color vision in adults with ADHD is warranted, along with the potential impact of these visual problems on driving performance. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. "Visual" Cortex Responds to Spoken Language in Blind Children.

    PubMed

    Bedny, Marina; Richardson, Hilary; Saxe, Rebecca

    2015-08-19

    Plasticity in the visual cortex of blind individuals provides a rare window into the mechanisms of cortical specialization. In the absence of visual input, occipital ("visual") brain regions respond to sound and spoken language. Here, we examined the time course and developmental mechanism of this plasticity in blind children. Nineteen blind and 40 sighted children and adolescents (4-17 years old) listened to stories and two auditory control conditions (unfamiliar foreign speech, and music). We find that "visual" cortices of young blind (but not sighted) children respond to sound. Responses to nonlanguage sounds increased between the ages of 4 and 17. By contrast, occipital responses to spoken language were maximal by age 4 and were not related to Braille learning. These findings suggest that occipital plasticity for spoken language is independent of plasticity for Braille and for sound. We conclude that in the absence of visual input, spoken language colonizes the visual system during brain development. Our findings suggest that early in life, human cortex has a remarkably broad computational capacity. The same cortical tissue can take on visual perception and language functions. Studies of plasticity provide key insights into how experience shapes the human brain. The "visual" cortex of adults who are blind from birth responds to touch, sound, and spoken language. To date, all existing studies have been conducted with adults, so little is known about the developmental trajectory of plasticity. We used fMRI to study the emergence of "visual" cortex responses to sound and spoken language in blind children and adolescents. We find that "visual" cortex responses to sound increase between 4 and 17 years of age. By contrast, responses to spoken language are present by 4 years of age and are not related to Braille-learning. These findings suggest that, early in development, human cortex can take on a strikingly wide range of functions. Copyright © 2015 the authors 0270-6474/15/3511674-08$15.00/0.

  20. Association Between Depression and Functional Vision Loss in Persons 20 Years of Age or Older in the United States, NHANES 2005–2008

    PubMed Central

    Zhang, Xinzhi; Bullard, Kai McKeever; Cotch, Mary Frances; Wilson, M. Roy; Rovner, Barry W.; McGwin, Gerald; Owsley, Cynthia; Barker, Lawrence; Crews, John E.; Saaddine, Jinan B.

    2013-01-01

    Importance This study provides further evidence from a national sample to generalize the relationship between depression and vision loss to adults across the age spectrum. Better recognition of depression among people reporting reduced ability to perform routine activities of daily living due to vision loss is warranted. Objectives To estimate, in a national survey of US adults 20 years of age or older, the prevalence of depression among adults reporting visual function loss and among those with visual acuity impairment. The relationship between depression and vision loss has not been reported in a nationally representative sample of US adults. Previous studies have been limited to specific cohorts and predominantly focused on the older population. Design The National Health and Nutrition Examination Survey (NHANES) 2005–2008. Setting A cross-sectional, nationally representative sample of adults, with prevalence estimates weighted to represent the civilian, noninstitutionalized US population. Participants A total of 10 480 US adults 20 years of age or older. Main Outcome Measures Depression, as measured by the 9-item Patient Health Questionnaire depression scale, and vision loss, as measured by visual function using a questionnaire and by visual acuity at examination. Results In 2005–2008, the estimated crude prevalence of depression (9-item Patient Health Questionnaire score of ≥10) was 11.3% (95% CI, 9.7%–13.2%) among adults with self-reported visual function loss and 4.8% (95% CI, 4.0%–5.7%) among adults without. The estimated prevalence of depression was 10.7% (95% CI, 8.0%–14.3%) among adults with presenting visual acuity impairment (visual acuity worse than 20/40 in the better-seeing eye) compared with 6.8% (95% CI, 5.8%–7.8%) among adults with normal visual acuity. After controlling for age, sex, race/ethnicity, marital status, living alone or not, education, income, employment status, health insurance, body mass index, smoking, binge drinking, general health status, eyesight worry, and major chronic conditions, self-reported visual function loss remained significantly associated with depression (overall odds ratio, 1.9 [95% CI, 1.6–2.3]), whereas the association between presenting visual acuity impairment and depression was no longer statistically significant. Conclusions and Relevance Self-reported visual function loss, rather than loss of visual acuity, is significantly associated with depression. Health professionals should be aware of the risk of depression among persons reporting visual function loss. PMID:23471505

  1. Visual Cone Arrestin 4 Contributes to Visual Function and Cone Health

    PubMed Central

    Deming, Janise D.; Pak, Joseph S.; Brown, Bruce M.; Kim, Moon K.; Aung, Moe H.; Eom, Yun Sung; Shin, Jung-a; Lee, Eun-Jin; Pardue, Machelle T.; Craft, Cheryl Mae

    2015-01-01

    Purpose Visual arrestins (ARR) play a critical role in shutoff of rod and cone phototransduction. When electrophysiological responses are measured for a single mouse cone photoreceptor, ARR1 expression can substitute for ARR4 in cone pigment desensitization; however, each arrestin may also contribute its own, unique role to modulate other cellular functions. Methods A combination of ERG, optokinetic tracking, immunohistochemistry, and immunoblot analysis was used to investigate the retinal phenotypes of Arr4 null mice (Arr4−/−) compared with age-matched control, wild-type mice. Results When 2-month-old Arr4−/− mice were compared with wild-type mice, they had diminished visual acuity and contrast sensitivity, yet enhanced ERG flicker response and higher photopic ERG b-wave amplitudes. In contrast, in older Arr4−/− mice, all ERG amplitudes were significantly reduced in magnitude compared with age-matched controls. Furthermore, in older Arr4−/− mice, the total cone numbers decreased and cone opsin protein immunoreactive expression levels were significantly reduced, while overall photoreceptor outer nuclear layer thickness was unchanged. Conclusions Our study demonstrates that Arr4−/− mice display distinct phenotypic differences when compared to controls, suggesting that ARR4 modulates essential functions in high acuity vision and downstream cellular signaling pathways that are not fulfilled or substituted by the coexpression of ARR1, despite its high expression levels in all mouse cones. Without normal ARR4 expression levels, cones slowly degenerate with increasing age, making this a new model to study age-related cone dystrophy. PMID:26284544

  2. A Tester for Carbon Nanotube Mode Lockers

    NASA Astrophysics Data System (ADS)

    Song, Yong-Won; Yamashita, Shinji

    2007-05-01

    We propose and demonstrate a tester for laser pulsating operation of carbon nanotubes employing a circulator with the extra degree of freedom of the second port to access diversified nanotube samples. The nanotubes are deposited onto the end facet of a dummy optical fiber by spray method that guarantees simple sample loading along with the minimized perturbation of optimized laser cavity condition. Resultant optical spectra, autocorrelation traces and pulse train of the laser outputs with qualified samples are presented.

  3. Endurance cycling results in extreme environments

    NASA Technical Reports Server (NTRS)

    Guertin, S. M.; Nguyen, D. N.; Scheick, L. Z.

    2003-01-01

    A new test bed for life testing flash memories in extreme environments is introducted. the test bed is based on a state-of-the-art development board. Since space applications often desire state-of-the-art devices, such a basis seems appropriate. Comparison of this tester to other such systems, including those with data presented here in the past is made. Limitations of different testers for varying applications are discussed. Recently developed data, using this test bed is also presented.

  4. Orbital fatigue tester for use in Skylab experiment T032

    NASA Technical Reports Server (NTRS)

    Sandorff, P. E.

    1973-01-01

    A prototype fatigue test machine is described which is suitable for use by an astronaut in conducting constant amplitude materials fatigue tests aboard a Skylab or space shuttle vehicle. The machine is comparised of a mechanical tester, which would be passed through a small (7.6-inch square) airlock to be supported in the space environment on an extendible boom, and a control console, which would provide remote control from within the space vehicle.

  5. Inspection tester for explosives

    DOEpatents

    Haas, Jeffrey S.; Simpson, Randall L.; Satcher, Joe H.

    2007-11-13

    An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.

  6. Inspection tester for explosives

    DOEpatents

    Haas, Jeffrey S.; Simpson, Randall L.; Satcher, Joe H.

    2010-10-05

    An inspection tester that can be used anywhere as a primary screening tool by non-technical personnel to determine whether a surface contains explosives. It includes a body with a sample pad. First and second explosives detecting reagent holders and dispensers are operatively connected to the body and the sample pad. The first and second explosives detecting reagent holders and dispensers are positioned to deliver the explosives detecting reagents to the sample pad. A is heater operatively connected to the sample pad.

  7. A dynamic tester to evaluate the thermal and moisture behaviour of the surface of textiles.

    PubMed

    Li, Wenbin; Xu, Weilin; Wang, Hao; Wang, Xin

    2016-01-01

    The thermal and moisture behaviour of the microclimate of textiles is crucial in determining the physiological comfort of apparel, but it has not been investigated sufficiently due to the lack of particular evaluation techniques. Based on sensing, temperature controlling and wireless communicating technology, a specially designed tester has been developed in this study to evaluate the thermal and moisture behaviour of the surface of textiles in moving status. A temperature acquisition system and a temperature controllable hotplate have been established to test temperature and simulate the heat of human body, respectively. Relative humidity of the surface of fabric in the dynamic process has been successfully tested through sensing. Meanwhile, wireless communication technology was applied to transport the acquired data of temperature and humidity to computer for further processing. Continuous power supply was achieved by intensive contact between an elastic copper plate and copper ring on the rotating shaft. This tester provides the platform to evaluate the thermal and moisture behaviour of textiles. It enables users to conduct a dynamic analysis on the temperature and humidity together with the thermal and moisture transport behaviour of the surface of fabric in moving condition. Development of this tester opens the door of investigation on the micro-climate of textiles in real time service, and eventually benefits the understanding of the sensation comfort and wellbeing of apparel wearers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Comparative testing of pulse oximeter probes.

    PubMed

    van Oostrom, Johannes H; Melker, Richard J

    2004-05-01

    The testing of pulse oximeter probes is generally limited to the integrity of the electrical circuit and does not include the optical properties of the probes. Few pulse oximeter testers evaluate the accuracy of both the monitor and the probe. We designed a study to compare the accuracy of nonproprietary probes (OSS Medical) designed for use with Nellcor, Datex-Ohmeda, and Criticare pulse oximeter monitors with that of their corresponding proprietary probes by using a commercial off-the-shelf pulse oximeter tester (Index). The Index pulse oximeter tester does include testing of the optical properties of the pulse oximeter probes. The pulse oximeter tester was given a controlled input that simulated acute apnea. Desaturation curves were automatically recorded from the pulse oximeter monitors with a data-collection computer. Comparisons between equivalent proprietary and nonproprietary probes were performed. Data were analyzed by using univariate and multivariate general linear model analysis. Five OSS Medical probe models were statistically better than the equivalent proprietary probes. The remainder of the probes were statistically similar. Comparative and simulation studies can have significant advantages over human studies because they are cost-effective, evaluate equipment in a clinically relevant scenario, and pose no risk to patients, but they are limited by the realism of the simulation. We studied the performance of pulse oximeter probes in a simulated environment. Our results show significant differences between some probes that affect the accuracy of measurement.

  9. Improving visual memory, attention, and school function with atomoxetine in boys with attention-deficit/hyperactivity disorder.

    PubMed

    Shang, Chi-Yung; Gau, Susan Shur-Fen

    2012-10-01

    Atomoxetine is efficacious in reducing symptoms of attention- deficit/hyperactivity disorder (ADHD), but its effect on visual memory and attention needs more investigation. This study aimed to assess the effect of atomoxetine on visual memory, attention, and school function in boys with ADHD in Taiwan. This was an open-label 12 week atomoxetine treatment trial among 30 drug-naíve boys with ADHD, aged 8-16 years. Before administration of atomoxetine, the participants were assessed using psychiatric interviews, the Wechsler Intelligence Scale for Children, 3rd edition (WISC-III), the school function of the Chinese version of the Social Adjustment Inventory for Children and Adolescents (SAICA), the Conners' Continuous Performance Test (CPT), and the tasks of the Cambridge Neuropsychological Test Automated Battery (CANTAB) involving visual memory and attention: Pattern Recognition Memory, Spatial Recognition Memory, and Reaction Time, which were reassessed at weeks 4 and 12. Our results showed there was significant improvement in pattern recognition memory and spatial recognition memory as measured by the CANTAB tasks, sustained attention and response inhibition as measured by the CPT, and reaction time as measured by the CANTAB after treatment with atomoxetine for 4 weeks or 12 weeks. In addition, atomoxetine significantly enhanced school functioning in children with ADHD. Our findings suggested that atomoxetine was associated with significant improvement in visual memory, attention, and school functioning in boys with ADHD.

  10. Visual Problems and Reading. Number 4.

    ERIC Educational Resources Information Center

    Griffin, Margaret; Eberly, Donald W.

    As one of a series commissioned by the National Reading Center to help inform all citizens about reading issues and to promote national functional literacy, this brochure is designed to acquaint readers with different forms of visual impairment, and describes their symptoms for easy recognition. Visual difficulties are classified into two major…

  11. Arrestin 1 and Cone Arrestin 4 Have Unique Roles in Visual Function in an All-Cone Mouse Retina

    PubMed Central

    Deming, Janise D.; Pak, Joseph S.; Shin, Jung-a; Brown, Bruce M.; Kim, Moon K.; Aung, Moe H.; Lee, Eun-Jin; Pardue, Machelle T.; Craft, Cheryl Mae

    2015-01-01

    Purpose Previous studies discovered cone phototransduction shutoff occurs normally for Arr1−/− and Arr4−/−; however, it is defective when both visual arrestins are simultaneously not expressed (Arr1−/−Arr4−/−). We investigated the roles of visual arrestins in an all-cone retina (Nrl−/−) since each arrestin has differential effects on visual function, including ARR1 for normal light adaptation, and ARR4 for normal contrast sensitivity and visual acuity. Methods We examined Nrl−/−, Nrl−/−Arr1−/−, Nrl−/−Arr4−/−, and Nrl−/−Arr1−/−Arr4−/− mice with photopic electroretinography (ERG) to assess light adaptation and retinal responses, immunoblot and immunohistochemical localization analysis to measure retinal expression levels of M- and S-opsin, and optokinetic tracking (OKT) to measure the visual acuity and contrast sensitivity. Results Study results indicated that Nrl−/− and Nrl−/−Arr4−/− mice light adapted normally, while Nrl−/−Arr1−/− and Nrl−/−Arr1−/−Arr4−/− mice did not. Photopic ERG a-wave, b-wave, and flicker amplitudes followed a general pattern in which Nrl−/−Arr4−/− amplitudes were higher than the amplitudes of Nrl−/−, while the amplitudes of Nrl−/−Arr1−/− and Nrl−/−Arr1−/−Arr4−/− were lower. All three visual arrestin knockouts had faster implicit times than Nrl−/− mice. M-opsin expression is lower when ARR1 is not expressed, while S-opsin expression is lower when ARR4 is not expressed. Although M-opsin expression is mislocalized throughout the photoreceptor cells, S-opsin is confined to the outer segments in all genotypes. Contrast sensitivity is decreased when ARR4 is not expressed, while visual acuity was normal except in Nrl−/−Arr1−/−Arr4−/−. Conclusions Based on the opposite visual phenotypes in an all-cone retina in the Nrl−/−Arr1−/− and Nrl−/−Arr4−/− mice, we conclude that ARR1 and ARR4 perform unique modulatory roles in cone photoreceptors. PMID:26624493

  12. Food-Associated Lactobacillus plantarum and Yeasts Inhibit the Genotoxic Effect of 4-Nitroquinoline-1-Oxide

    PubMed Central

    Prete, Roberta; Tofalo, Rosanna; Federici, Ermanno; Ciarrocchi, Aurora; Cenci, Giovanni; Corsetti, Aldo

    2017-01-01

    Lactic acid bacteria and yeasts, representing the prevailing microbiota associated with different foods generally consumed without any cooking, were identified and characterized in vitro for some functional properties, such as acid-bile tolerance and antigenotoxic activity. In particular, 22 Lactobacillus plantarum strains and 14 yeasts were studied. The gastro-intestinal tract tolerance of all the strains was determined by exposing washed cell suspensions at 37°C to a simulated gastric juice (pH 2.0), containing pepsin (0.3% w/v) and to a simulated small intestinal juice (pH 8.0), containing pancreatin (1 mg mL-1) and bile extract (0.5%), thus monitoring changes in total viable count. In general, following a strain-dependent behavior, all the tested strains persisted alive after combined acid-bile challenge. Moreover, many strains showed high in vitro inhibitory activity against a model genotoxin, 4-nitroquinoline-1-oxide (4-NQO), as determined by the short-term method, SOS-Chromotest. Interestingly, the supernatants from bacteria- or yeasts-genotoxin co-incubations exhibited a suppression on SOS-induction produced by 4-NQO on the tester strain Escherichia coli PQ37 (sfiA::lacZ) exceeding, in general, the value of 75%. The results highlight that food associated microorganisms may reach the gut in viable form and prevent genotoxin DNA damage in situ. Our experiments can contribute to elucidate the functional role of food-associated microorganisms general recognized as safe ingested with foods as a part of the diet. PMID:29234315

  13. STS-44 Space Shuttle mission report

    NASA Technical Reports Server (NTRS)

    Fricke, Robert W.

    1992-01-01

    The STS-44 Space Shuttle Program Mission Report is a summary of the vehicle subsystem operations during the forty-fourth flight of the Space Shuttle Program and the tenth flight of the Orbiter vehicle Atlantis (OV-104). In addition to the Atlantis vehicle, the flight vehicle consisted of the following: an External Tank (ET) designated as ET-53 (LWT-46); three Space Shuttle main engines (SSME's) (serial numbers 2015, 2030, and 2029 in positions 1, 2, and 3, respectively); and two Solid Rocket Boosters (SRB's) designated as BI-047. The lightweight redesigned Solid Rocket Motors (RSRM's) installed in each one of the SRB's were designated as 360L019A for the left SRB and 360W019B for the right SRB. The primary objective of the STS-44 mission was to successfully deploy the Department of Defense (DOD) Defense Support Program (DSP) satellite/inertial upper stage (IUS) into a 195 nmi. earth orbit at an inclination of 28.45 deg. Secondary objectives of this flight were to perform all operations necessary to support the requirements of the following: Terra Scout, Military Man in Space (M88-1), Air Force Maui Optical System Calibration Test (AMOS), Cosmic Radiation Effects and Activation Monitor (CREAM), Shuttle Activation Monitor (SAM), Radiation Monitoring Equipment-3 (RME-3), Visual Function Tester-1 (VFT-1), and the Interim Operational Contamination Monitor (IOCM) secondary payloads/experiments.

  14. Visual disability, visual function, and myopia among rural chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES)--report 1.

    PubMed

    Congdon, Nathan; Wang, Yunfei; Song, Yue; Choi, Kai; Zhang, Mingzhi; Zhou, Zhongxia; Xie, Zhenling; Li, Liping; Liu, Xueyu; Sharma, Abhishek; Wu, Bin; Lam, Dennis S C

    2008-07-01

    To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (< or = 6/12 in the better eye) was 41.2%, 19.3%, and 0.5%, respectively. Myopia < -0.5, < -2.0, and < -6.0 D in both eyes was present in 62.3%, 31.1%, and 1.9% of the subjects, respectively. Among the children with visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P < 0.001) more presenting visual disability and myopia < -2.0 D than did the boys. More myopic refractive error was associated with worse self-reported visual function (ANOVA trend test, P < 0.001). Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.

  15. International Conference (4th) on Nanostructured Materials Held in Stockholm, Sweden on 14-19 June 1998. Special Volume - Part A. Volume 12, Numbers 1-4, 1999

    DTIC Science & Technology

    1998-06-19

    correlation was found between the X - ray grain size and the TEM grain size. Table 2 contains the hardness and density data for the nanocrystalline 5083...temperature with a Neophot hardness tester and a load of 0.2 N. RESULTS AND DISCUSSION X - ray diffraction and transmission electron microscopy combined with...For Single- Wall Carbon Nanotubes by Raman Scattering Technique Microstructure Change in Co46AI19035 Granular Thin Films by Annealing X - Ray

  16. Use of GetCheckedOnline, a Comprehensive Web-based Testing Service for Sexually Transmitted and Blood-Borne Infections

    PubMed Central

    Salway, Travis; Haag, Devon; Fairley, Christopher K; Wong, Jason; Grennan, Troy; Uddin, Zhaida; Buchner, Christopher S; Wong, Tom; Krajden, Mel; Tyndall, Mark; Shoveller, Jean; Ogilvie, Gina

    2017-01-01

    Background The British Columbia Centre for Disease Control implemented a comprehensive Web-based testing service GetCheckedOnline (GCO) in September 2014 in Vancouver, Canada. GCO’s objectives are to increase testing for sexually transmitted and blood-borne infections (STBBIs), reach high-prevalence populations facing testing barriers, and increase clinical STI service capacity. GCO was promoted through email invitations to provincial STI clinic clients, access codes to clients unable to access immediate clinic-based testing (deferred testers), and a campaign to gay, bisexual, and other men who have sex with men (MSM). Objective The objective of the study was to report on characteristics of GCO users, use and test outcomes (overall and by promotional strategy) during this pilot phase. Methods We used GCO program data, website metrics, and provincial STI clinic records to describe temporal trends, progression through the service pathway, and demographic, risk, and testing outcomes for individuals creating GCO accounts during the first 15 months of implementation. Results Of 868 clients creating accounts, 318 (36.6%) submitted specimens, of whom 96 (30.2%) tested more than once and 10 (3.1%) had a positive STI diagnosis. The proportion of clients submitting specimens increased steadily over the course of the pilot phase following introduction of deferred tester codes. Clients were diverse with respect to age, gender, and ethnicity, although youth and individuals of nonwhite ethnicity were underrepresented. Of the 506 clients completing risk assessments, 215 (42.5%) were MSM, 89 (17.6%) were symptomatic, 47 (9.3%) were STI contacts, 232 (45.8%) reported condomless sex, 146 (28.9%) reported ≥4 partners in the past 3 months, and 76 (15.0%) reported a recent STI. A total of 63 (12.5%) GCO clients were testing for the first time. For 868 accounts created, 337 (38.8%) were by clinic invitations (0 diagnoses), 298 (34.3%) were by deferred testers (6 diagnoses), 194 (22.4%) were by promotional campaign (3 diagnoses), and 39 (4.5%) were by other means (1 diagnosis). Conclusions Our evaluation suggests that GCO is an acceptable and feasible approach to engage individuals in testing. Use by first-time testers, repeated use, and STI diagnosis of individuals unable to access immediate clinic-based testing suggest GCO may facilitate uptake of STBBI testing and earlier diagnosis. Use by MSM and individuals reporting sexual risk suggests GCO may reach populations with a higher risk of STI. Motivation to test (eg, unable to access clinical services immediately) appears a key factor underlying GCO use. These findings identify areas for refinement of the testing model, further promotion, and future research (including understanding reasons for drop-off through the service pathway and more comprehensive evaluation of effectiveness). Increased uptake and diagnosis corresponding with expansion of the service within British Columbia will permit future evaluation of this service across varying populations and settings. PMID:28320690

  17. The yeast Saccharomyces cerevisiae DNA polymerase IV: possible involvement in double strand break DNA repair.

    PubMed

    Leem, S H; Ropp, P A; Sugino, A

    1994-08-11

    We identified and purified a new DNA polymerase (DNA polymerase IV), which is similar to mammalian DNA polymerase beta, from Saccharomyces cerevisiae and suggested that it is encoded by YCR14C (POLX) on chromosome III. Here, we provided a direct evidence that the purified DNA polymerase IV is indeed encoded by POLX. Strains harboring a pol4 deletion mutation exhibit neither mitotic growth defect nor a meiosis defect, suggesting that DNA polymerase IV participates in nonessential functions in DNA metabolism. The deletion strains did not exhibit UV-sensitivity. However, they did show weak sensitivity to MMS-treatment and exhibited a hyper-recombination phenotype when intragenic recombination was measured during meiosis. Furthermore, MAT alpha pol4 delta segregants had a higher frequency of illegitimate mating with a MAT alpha tester strain than that of wild-type cells. These results suggest that DNA polymerase IV participates in a double-strand break repair pathway. A 3.2kb of the POL4 transcript was weakly expressed in mitotically growing cells. During meiosis, a 2.2 kb POL4 transcript was greatly induced, while the 3.2 kb transcript stayed at constant levels. This induction was delayed in a swi4 delta strain during meiosis, while no effect was observed in a swi6 delta strain.

  18. Metformin improves cardiac function in mice with heart failure after myocardial infarction by regulating mitochondrial energy metabolism.

    PubMed

    Sun, Dan; Yang, Fei

    2017-04-29

    To investigate whether metformin can improve the cardiac function through improving the mitochondrial function in model of heart failure after myocardial infarction. Male C57/BL6 mice aged about 8 weeks were selected and the anterior descending branch was ligatured to establish the heart failure model after myocardial infarction. The cardiac function was evaluated via ultrasound after 3 days to determine the modeling was successful, and the mice were randomly divided into two groups. Saline group (Saline) received the intragastric administration of normal saline for 4 weeks, and metformin group (Met) received the intragastric administration of metformin for 4 weeks. At the same time, Shame group (Sham) was set up. Changes in cardiac function in mice were detected at 4 weeks after operation. Hearts were taken from mice after 4 weeks, and cell apoptosis in myocardial tissue was detected using TUNEL method; fresh mitochondria were taken and changes in oxygen consumption rate (OCR) and respiratory control rate (RCR) of mitochondria in each group were detected using bio-energy metabolism tester, and change in mitochondrial membrane potential (MMP) of myocardial tissue was detected via JC-1 staining; the expressions and changes in Bcl-2, Bax, Sirt3, PGC-1α and acetylated PGC-1α in myocardial tissue were detected by Western blot. RT-PCR was used to detect mRNA levels in Sirt3 in myocardial tissues. Metformin improved the systolic function of heart failure model rats after myocardial infarction and reduced the apoptosis of myocardial cells after myocardial infarction. Myocardial mitochondrial respiratory function and membrane potential were decreased after myocardial infarction, and metformin treatment significantly improved the mitochondrial respiratory function and mitochondrial membrane potential; Metformin up-regulated the expression of Sirt3 and the activity of PGC-1α in myocardial tissue of heart failure after myocardial infarction. Metformin decreases the acetylation level of PGC-1α through up-regulating Sirt3, mitigates the damage to mitochondrial membrane potential of model of heart failure after myocardial infarction and improves the respiratory function of mitochondria, thus improving the cardiac function of mice. Copyright © 2017. Published by Elsevier Inc.

  19. Retinal vessel caliber among people with acquired immunodeficiency syndrome: relationships with visual function.

    PubMed

    Kalyani, Partho S; Fawzi, Amani A; Gangaputra, Sapna; van Natta, Mark L; Hubbard, Larry D; Danis, Ronald P; Thorne, Jennifer E; Holland, Gary N

    2012-03-01

    To evaluate relationships between retinal vessel caliber and tests of visual function among people with AIDS. Longitudinal, observational cohort study. We evaluated data for participants without ocular opportunistic infections at initial examination (baseline) in the Longitudinal Studies of the Ocular Complications of AIDS (1998-2008). Visual function was evaluated with best-corrected visual acuity, Goldmann perimetry, automated perimetry (Humphrey Field Analyzer), and contrast sensitivity (CS) testing. Semi-automated grading of fundus photographs (1 eye/participant) determined central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), and arteriole-to-venule ratio (AVR) at baseline. Multiple linear regression models, using forward selection, sought independent relationships between indices and visual function variables. Included were 1250 participants. Smaller AVR was associated with reduced visual field by Goldmann perimetry (P = .003) and worse mean deviation (P = .02) on automated perimetry and possibly with worse pattern standard deviation (PSD) on automated perimetry (P = .06). There was a weak association between smaller AVR and worse CS (P = .07). Relationships were independent of antiretroviral therapy and level of immunodeficiency (CD4+ T lymphocyte count, human immunodeficiency virus [HIV] RNA blood level). On longitudinal analysis, retinal vascular indices at baseline did not predict changes in visual function. Variation in retinal vascular indices is associated with abnormal visual function in people with AIDS, manifested by visual field loss and possibly by reduced CS. Relationships are consistent with the hypothesis that HIV-related retinal vasculopathy is a contributing factor to vision dysfunction among HIV-infected individuals. Longitudinal studies are needed to determine whether changes in indices predict change in visual function. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Trends in testing behaviours for hepatitis C virus infection and associated determinants: results from population-based laboratory surveillance in Alberta, Canada (1998-2001).

    PubMed

    Jayaraman, G C; Lee, B; Singh, A E; Preiksaitis, J K

    2007-04-01

    Little is currently known about hepatitis C virus (HCV) test seeking behaviours at the population level. Given the centralized nature of testing for HCV infection in the province of Alberta, Canada, we had an opportunity to examine HCV testing behaviour at the population level on all newly diagnosed HCV-positive cases using laboratory data to validate the time and number of prior tests for each case. Record linkage identified 3323, 2937, 2660 and 2703 newly diagnosed cases of HCV infections in Alberta during 1998, 1999, 2000 and 2001, respectively, corresponding to age-adjusted rates of 149.8, 129, 114.3 and 113.7 per 100,000 population during these years, respectively. Results from secondary analyses of laboratory data suggest that the majority of HCV cases (95.3%) who were newly diagnosed between 1998 and 2001 were first-time testers for HCV infection. Among repeat testers, analysis of a negative test result within 1 year prior to a first of a positive test report suggests that 211 (38.4%) may be seroconvertors. These findings suggest that 339 or 61.7% of repeat testers may not have discovered their serostatus within 1 year of infection. Among this group, HCV testing was sought infrequently, with a median interval of 2.3 years between the last negative and first positive test. This finding is of concern given the risks for HCV transmission, particularly if risk-taking behaviours are not reduced because of unknown serostatus. These findings also reinforce the need to make the most of each test-seeking event with proper counselling and other appropriate support services.

  1. Contrasting the use of 2 vision-specific quality of life questionnaires in subjects with open-angle glaucoma.

    PubMed

    Wren, Patricia A; Musch, David C; Janz, Nancy K; Niziol, Leslie M; Guire, Kenneth E; Gillespie, Brenda W

    2009-01-01

    To compare 2 vision-specific functional status measures to each other and to clinical parameters in the Collaborative Initial Glaucoma Treatment Study (CIGTS). CIGTS participants completed the Visual Activities Questionnaire (VAQ) and the National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and were tested for visual field (VF) and visual acuity (VA). In all, 426 subjects contributed the VAQ and NEI-VFQ scores at 54 months. Pearson correlations were used to assess associations. The VAQ subscales (range, 0 to 100) that assessed light-dark adaptation (mean=66.1), glare disability (66.4), and acuity/spatial vision (67.7) indicated vision-related functions that CIGTS participants found most difficult. On the NEI-VFQ, subjects reported high levels of visual functioning, with mean >/=90 (out of 100) on the total score and in 9 of 12 subscales. General vision (mean=82.6) received the lowest subscale score. Two subscales common to both questionnaires were highly correlated: VA (r=0.68) and peripheral vision (r=0.77) (both P<0.0001). Correlations between participants' perceptions and clinical measures of visual function were in the expected direction, but weaker. Stronger associations were found between clinical measures and the NEI-VFQ than the VAQ. Better eye VF and worse eye VA had the highest number of significant correlations with subjects' perceptions of their visual function. Increasing VF loss was associated with a significant decrease in the overall and peripheral vision subscale scores from both questionnaires, and also several other subscales. CIGTS patients reported excellent visual function on both the NEI-VFQ and VAQ. These findings will help researchers interested in assessing patients' perceptions of their visual function make an informed selection when choosing between the VAQ and the NEI-VFQ.

  2. The Efficiency of a Visual Skills Training Program on Visual Search Performance

    PubMed Central

    Krzepota, Justyna; Zwierko, Teresa; Puchalska-Niedbał, Lidia; Markiewicz, Mikołaj; Florkiewicz, Beata; Lubiński, Wojciech

    2015-01-01

    In this study, we conducted an experiment in which we analyzed the possibilities to develop visual skills by specifically targeted training of visual search. The aim of our study was to investigate whether, for how long and to what extent a training program for visual functions could improve visual search. The study involved 24 healthy students from the Szczecin University who were divided into two groups: experimental (12) and control (12). In addition to regular sports and recreational activities of the curriculum, the subjects of the experimental group also participated in 8-week long training with visual functions, 3 times a week for 45 min. The Signal Test of the Vienna Test System was performed four times: before entering the study, after first 4 weeks of the experiment, immediately after its completion and 4 weeks after the study terminated. The results of this experiment proved that an 8-week long perceptual training program significantly differentiated the plot of visual detecting time. For the visual detecting time changes, the first factor, Group, was significant as a main effect (F(1,22)=6.49, p<0.05) as well as the second factor, Training (F(3,66)=5.06, p<0.01). The interaction between the two factors (Group vs. Training) of perceptual training was F(3,66)=6.82 (p<0.001). Similarly, for the number of correct reactions, there was a main effect of a Group factor (F(1,22)=23.40, p<0.001), a main effect of a Training factor (F(3,66)=11.60, p<0.001) and a significant interaction between factors (Group vs. Training) (F(3,66)=10.33, p<0.001). Our study suggests that 8-week training of visual functions can improve visual search performance. PMID:26240666

  3. THE NAVICULAR POSITION TEST – A RELIABLE MEASURE OF THE NAVICULAR BONE POSITION DURING REST AND LOADING

    PubMed Central

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard; Boesen, Morten Ilum

    2011-01-01

    Background: Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investigate the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test. Objectives: The purpose was to describe a modified version of the Feiss Line test and to determine the intra- and inter-tester reliability of this new foot alignment test. To emphasize the purpose of the modified test, the authors have named it The Navicular Position Test. Methods: Intra- and inter-tester reliability were evaluated of The Navicular Position Test with the use of ICC (interclass correlation coefficient) and Bland-Altman limits of agreement on 43 healthy, young, subjects. Results: Inter-tester mean difference -0.35 degrees [–1.32; 0.62] p = 0.47. Bland-Altman limits of agreement –6.55 to 5.85 degrees, ICC = 0.94. Intra-tester mean difference 0.47 degrees [–0.57; 1.50] p = 0.37. Bland-Altman limits of agreement –6.15 to 7.08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability. When cut off values to categorize the MLA into planus, rectus, or cavus feet, has been determined and presented, the test could be used in prospective observational studies investigating the role of the arch type on the development of various lower limb injuries. PMID:21904698

  4. Helium Bottle Pressure Measurement by Portable Ultrasonic Technique

    DTIC Science & Technology

    1989-02-07

    revision extends the study to include EMI testing, and -develorynent of g Rrotgtype tester . The Contractor shall: 1. Perform EMI test of ultrasonic eq...amp/1 watt power ap- plied to the bridgerires. The tester pulse of 250 volts for 100 ns at 1500 pps has an average value of 250v x 100ns x 1500pps...34 connector. Mount transducer in fixture and connect transducer to cable microdot connector. 5. Pulse-Echo transit time measurement: Assure that the

  5. Design of a MATLAB(registered trademark) Image Comparison and Analysis Tool for Augmentation of the Results of the Ann Arbor Distortion Test

    DTIC Science & Technology

    2016-06-25

    The equipment used in this procedure includes: Ann Arbor distortion tester with 50-line grating reticule, IQeye 720 digital video camera with 12...and import them into MATLAB. In order to digitally capture images of the distortion in an optical sample, an IQeye 720 video camera with a 12... video camera and Ann Arbor distortion tester. Figure 8. Computer interface for capturing images seen by IQeye 720 camera. Once an image was

  6. Small-Bolt Torque-Tension Tester

    NASA Technical Reports Server (NTRS)

    Posey, Alan J.

    2009-01-01

    The device described here measures the torque-tension relationship for fasteners as small as #0. The small-bolt tester consists of a plate of high-strength steel into which three miniature load cells are recessed. The depth of the recess is sized so that the three load cells can be shimmed, the optimum height depending upon the test hardware. The three miniature load cells are arranged in an equilateral triangular configuration with the test bolt aligned with the centroid of the three. This is a kinematic arrangement.

  7. Attitudes towards and perceptions of visual loss and its causes among Hong Kong Chinese adults.

    PubMed

    Lau, Joseph Tak Fai; Lee, Vincent; Fan, Dorothy; Lau, Mason; Michon, John

    2004-06-01

    As part of a study of visual function among Hong Kong Chinese adults, their attitudes and perceptions related to visual loss were examined. These included fear of visual loss, negative functional impacts of visual loss, the relationship between ageing and visual loss and help-seeking behaviours related to visual loss. Demographic factors associated with these variables were also studied. The study population were people aged 40 and above randomly selected from the Shatin district of Hong Kong. The participants underwent eye examinations that included visual acuity, intraocular pressure measurement, visual field, slit-lamp biomicroscopy and ophthalmoscopy. The primary cause of visual disability was recorded. The participants were also asked about their attitudes and perceptions regarding visual loss using a structured questionnaire. The prevalence of bilateral visual disability was 2.2% among adults aged 40 or above and 6.4% among adults aged 60 or above. Nearly 36% of the participants selected blindness as the most feared disabling medical condition, which was substantially higher than conditions such as dementia, loss of limbs, deafness or aphasia. Inability to take care of oneself (21.0%), inconvenience related to mobility (20.2%) and inability to work (14.8%) were the three most commonly mentioned 'worst impact' effects of visual loss. Fully 68% of the participants believed that loss of vision is related to ageing. A majority of participants would seek help and advice from family members in case of visual loss. Visual function is perceived to be very important by Hong Kong Chinese adults. The fear of visual loss is widespread and particularly affects self-care and functional abilities. Visual loss is commonly seen as related to ageing. Attitudes and perceptions in this population may be modified by educational and outreach efforts in order to take advantage of preventive measures.

  8. Moderate perinatal thyroid hormone insufficiency alters visual system function in adult rats.

    PubMed

    Boyes, William K; Degn, Laura; George, Barbara Jane; Gilbert, Mary E

    2018-04-21

    Thyroid hormone (TH) is critical for many aspects of neurodevelopment and can be disrupted by a variety of environmental contaminants. Sensory systems, including audition and vision are vulnerable to TH insufficiencies, but little data are available on visual system development at less than severe levels of TH deprivation. The goal of the current experiments was to explore dose-response relations between graded levels of TH insufficiency during development and the visual function of adult offspring. Pregnant Long Evans rats received 0 or 3 ppm (Experiment 1), or 0, 1, 2, or 3 ppm (Experiment 2) of propylthiouracil (PTU), an inhibitor of thyroid hormone synthesis, in drinking water from gestation day (GD) 6 to postnatal day (PN) 21. Treatment with PTU caused dose-related reductions of serum T4, with recovery on termination of exposure, and euthyroidism by the time of visual function testing. Tests of retinal (electroretinograms; ERGs) and visual cortex (visual evoked potentials; VEPs) function were assessed in adult offspring. Dark-adapted ERG a-waves, reflecting rod photoreceptors, were increased in amplitude by PTU. Light-adapted green flicker ERGs, reflecting M-cone photoreceptors, were reduced by PTU exposure. UV-flicker ERGs, reflecting S-cones, were not altered. Pattern-elicited VEPs were significantly reduced by 2 and 3 ppm PTU across a range of stimulus contrast values. The slope of VEP amplitude-log contrast functions was reduced by PTU, suggesting impaired visual contrast gain. Visual contrast gain primarily reflects function of visual cortex, and is responsible for adjusting sensitivity of perceptual mechanisms in response to changing visual scenes. The results indicate that moderate levels of pre-and post-natal TH insufficiency led to alterations in visual function of adult rats, including both retinal and visual cortex sites of dysfunction. Copyright © 2018. Published by Elsevier B.V.

  9. Designing an Electronics Data Package for Printed Circuit Boards (PCBs)

    DTIC Science & Technology

    2013-08-01

    finished PCB flatness deviation should be less than 0.010 inches per inch. 4  The minimum copper wall thickness of plated-thru holes should be...Memory Card International Association)  IPC-6015 MCM-L (Multi-Chip Module – Laminated )  IPC-6016 HDI (High Density Interconnect)  IPC-6018...Interconnect ICT In Circuit Tester IPC Association Connecting Electronics Industries MCM-L Multi-Chip Module – Laminated MIL Military NEMA National

  10. Effect of mo Content on Microstructure and Properties of Laser Cladding Fe-BASED Alloy Coatings

    NASA Astrophysics Data System (ADS)

    Xiaoli, Ma; Kaiming, Wang; Hanguang, Fu; Jiang, Ju; Yongping, Lei; Dawei, Yi

    Mo alloying Fe-based coating was fabricated on the surface of Q235 steel by using 6 kW fiber laser. The effects of Mo additions on the microstructure, microhardness and wear resistance of the cladding layer were studied by means of optical microscopy (OM), scanning electron microscope (SEM), X-ray diffraction (XRD), energy dispersive spectrometer (EDS), Vickers hardness tester and M-200 ring block wear tester. Research results showed that the microstructure of Mo-free cladding layer mainly consisted of matrix and eutectic structure. The matrix was martensite and retained austenite. The eutectic structure mainly consisted of M2(B,C) and M7(C,B)3 type of eutectic borocarbides. With the increase of Mo content, there was no significant change in the matrix. However, the eutectic structure was transformed from M2(B,C)- and M7(C,B)3-type borocarbides into M2(B,C)-, M7(C,B)3- and M23(C,B)6-type borocarbides. When the content of Mo is 4.0wt.%, the Mo2C-type carbide appear on the matrix, and parts of the borocarbide networks are broken. The change of microhardness of the cladding layer was not obvious with the increase of Mo content. But the increase of Mo content increases the wear resistance of the cladding layer. The wear resistance of cladding layer with 4.0wt.% Mo is 2.4 times as much as the cladding layer which is Mo-free.

  11. Barriers to Fully Implementing Integrated Logistics Support (ILS) in System Acquisition as Perceived by ILS Managers and Program Managers at the Aeronautical Systems Division

    DTIC Science & Technology

    1982-09-01

    is to structure, within Systems Engineering, a process to systematically pull together all the engineering functions that contribute to the design...staff and AiD ptple in the SPOs. There is not enough communication. The DPFL is pulled two ways. 160. Dual chain helps IWll get things done. 103 166...involvement from users, testers, and logisticians. I’d pull AFLC into the development early. On the A-X I wanted logistics inputs early, but it never happened

  12. Training-induced recovery of low-level vision followed by mid-level perceptual improvements in developmental object and face agnosia

    PubMed Central

    Lev, Maria; Gilaie-Dotan, Sharon; Gotthilf-Nezri, Dana; Yehezkel, Oren; Brooks, Joseph L; Perry, Anat; Bentin, Shlomo; Bonneh, Yoram; Polat, Uri

    2015-01-01

    Long-term deprivation of normal visual inputs can cause perceptual impairments at various levels of visual function, from basic visual acuity deficits, through mid-level deficits such as contour integration and motion coherence, to high-level face and object agnosia. Yet it is unclear whether training during adulthood, at a post-developmental stage of the adult visual system, can overcome such developmental impairments. Here, we visually trained LG, a developmental object and face agnosic individual. Prior to training, at the age of 20, LG's basic and mid-level visual functions such as visual acuity, crowding effects, and contour integration were underdeveloped relative to normal adult vision, corresponding to or poorer than those of 5–6 year olds (Gilaie-Dotan, Perry, Bonneh, Malach & Bentin, 2009). Intensive visual training, based on lateral interactions, was applied for a period of 9 months. LG's directly trained but also untrained visual functions such as visual acuity, crowding, binocular stereopsis and also mid-level contour integration improved significantly and reached near-age-level performance, with long-term (over 4 years) persistence. Moreover, mid-level functions that were tested post-training were found to be normal in LG. Some possible subtle improvement was observed in LG's higher-order visual functions such as object recognition and part integration, while LG's face perception skills have not improved thus far. These results suggest that corrective training at a post-developmental stage, even in the adult visual system, can prove effective, and its enduring effects are the basis for a revival of a developmental cascade that can lead to reduced perceptual impairments. PMID:24698161

  13. Training-induced recovery of low-level vision followed by mid-level perceptual improvements in developmental object and face agnosia.

    PubMed

    Lev, Maria; Gilaie-Dotan, Sharon; Gotthilf-Nezri, Dana; Yehezkel, Oren; Brooks, Joseph L; Perry, Anat; Bentin, Shlomo; Bonneh, Yoram; Polat, Uri

    2015-01-01

    Long-term deprivation of normal visual inputs can cause perceptual impairments at various levels of visual function, from basic visual acuity deficits, through mid-level deficits such as contour integration and motion coherence, to high-level face and object agnosia. Yet it is unclear whether training during adulthood, at a post-developmental stage of the adult visual system, can overcome such developmental impairments. Here, we visually trained LG, a developmental object and face agnosic individual. Prior to training, at the age of 20, LG's basic and mid-level visual functions such as visual acuity, crowding effects, and contour integration were underdeveloped relative to normal adult vision, corresponding to or poorer than those of 5-6 year olds (Gilaie-Dotan, Perry, Bonneh, Malach & Bentin, 2009). Intensive visual training, based on lateral interactions, was applied for a period of 9 months. LG's directly trained but also untrained visual functions such as visual acuity, crowding, binocular stereopsis and also mid-level contour integration improved significantly and reached near-age-level performance, with long-term (over 4 years) persistence. Moreover, mid-level functions that were tested post-training were found to be normal in LG. Some possible subtle improvement was observed in LG's higher-order visual functions such as object recognition and part integration, while LG's face perception skills have not improved thus far. These results suggest that corrective training at a post-developmental stage, even in the adult visual system, can prove effective, and its enduring effects are the basis for a revival of a developmental cascade that can lead to reduced perceptual impairments. © 2014 The Authors. Developmental Science Published by John Wiley & Sons Ltd.

  14. [Design of the psychology tester based on ZigBee technology].

    PubMed

    Zhong, Tianping; Tang, Liming

    2012-09-01

    To design a psychological state tester based on ZigBee wireless technology. Through analog circuit preprocessing, the heartbeat collected by the pulse sensor will be transformed into digital signal from analog signal, and then can be processed and displayed after transported to the personal computer through the Zigbee wireless communicate units. The data will be retrieval and playback for the measurement of psychology. The experiments show that the device is able to acquire the pulse wave of the human body in real-time, at the same time, through the ZigBee wireless network, it can accomplish real-time, secure and reliable communications, and it also can be used in the research of testing the mental state of the individual. Through the application of the ZigBee communicate technology; the psychology tester can collect the pulse signal to reflect the individual's mental state in different conditions. So it will be applicable to a wide range of psychology measurement and other areas.

  15. Rolling-element fatigue life of AMS 5749 corrosion resistant, high temperature bearing steel

    NASA Technical Reports Server (NTRS)

    Parker, R. J.; Hodder, R. S.

    1977-01-01

    The rolling element fatigue lives of AMS 5749 and AISI M-50 were compared in tests run in the five ball fatigue tester and the rolling contact fatigue tester. The effects of double vacuum melting and retained austenite on the life of AMS 5749 were determined in five ball fatigue tests. The double vacuum melting process consisted of induction vacuum melting followed by vacuum arc remelting (VIM-VAR). In the five ball tests, VIM-VAR AMS 5749 gave lives at least six times that of VIM-VAR AISI M-50. Similar tests in the rolling contact fatigue tester showed no significant difference in the lives of the two materials. The rolling element fatigue life of VIM-VAR AMS 5749 was at least 14 times that of vacuum induction melted AMS 5749. A trend toward increased rolling element fatigue life with decreased retained austenite is apparent, but the confidence that all experimental differences are significant is not great.

  16. Peripheral Visual Fields in ABCA4 Stargardt Disease and Correlation With Disease Extent on Ultra-widefield Fundus Autofluorescence.

    PubMed

    Abalem, Maria Fernanda; Otte, Benjamin; Andrews, Chris; Joltikov, Katherine A; Branham, Kari; Fahim, Abigail T; Schlegel, Dana; Qian, Cynthia X; Heckenlively, John R; Jayasundera, Thiran

    2017-12-01

    To evaluate the disease extent on ultra-widefield fundus autofluorescence (UWF-FAF) in patients with ABCA4 Stargardt disease (STGD) and correlate these data with functional outcome measures. Retrospective cross-sectional study. Setting: Kellogg Eye Center, University of Michigan. Sixty-five patients with clinical diagnosis and proven pathogenic variants in the ABCA4 gene. Observational Procedures: The UWF-FAF images were obtained using Optos (200 degrees) and classified into 3 types. Functional testing included kinetic widefield perimetry, full-field electroretinogram (ffERG), and visual acuity (VA). All results were evaluated with respect to UWF-FAF classification. Classification of UWF-FAF; area comprising the I4e, III4e, and IV4e isopters; ffERG patterns; and VA. For UWF-FAF, 27 subjects (41.5%) were classified as type I, 17 (26.2%) as type II, and 21 (32.4%) as type III. The area of each isopter correlated inversely with the extent of the disease and all isopters were able to detect differences among UWF-FAF types (IV4e, P = .0013; III4e, P = .0003; I4e, P < .0001 = 3.93e -8 ). ffERG patterns and VA were also different among the 3 UWF-FAF types (P < .001 = 6.61e- 6 and P < .001 = 7.3e -5 , respectively). Patients with widespread disease presented with more constriction of peripheral visual fields and had more dysfunction on ffERG and worse VA compared to patients with disease confined to the macula. UWF-FAF images may provide information for estimating peripheral and central visual function in STGD. Copyright © 2017. Published by Elsevier Inc.

  17. Decoding brain responses to pixelized images in the primary visual cortex: implications for visual cortical prostheses

    PubMed Central

    Guo, Bing-bing; Zheng, Xiao-lin; Lu, Zhen-gang; Wang, Xing; Yin, Zheng-qin; Hou, Wen-sheng; Meng, Ming

    2015-01-01

    Visual cortical prostheses have the potential to restore partial vision. Still limited by the low-resolution visual percepts provided by visual cortical prostheses, implant wearers can currently only “see” pixelized images, and how to obtain the specific brain responses to different pixelized images in the primary visual cortex (the implant area) is still unknown. We conducted a functional magnetic resonance imaging experiment on normal human participants to investigate the brain activation patterns in response to 18 different pixelized images. There were 100 voxels in the brain activation pattern that were selected from the primary visual cortex, and voxel size was 4 mm × 4 mm × 4 mm. Multi-voxel pattern analysis was used to test if these 18 different brain activation patterns were specific. We chose a Linear Support Vector Machine (LSVM) as the classifier in this study. The results showed that the classification accuracies of different brain activation patterns were significantly above chance level, which suggests that the classifier can successfully distinguish the brain activation patterns. Our results suggest that the specific brain activation patterns to different pixelized images can be obtained in the primary visual cortex using a 4 mm × 4 mm × 4 mm voxel size and a 100-voxel pattern. PMID:26692860

  18. A novel apparatus for testing binocular function using the 'CyberDome' three-dimensional hemispherical visual display system.

    PubMed

    Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K

    2009-11-01

    Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.

  19. Synthesized multi-station tribo-test system for bio-tribological evaluation in vitro

    NASA Astrophysics Data System (ADS)

    Wu, Tonghai; Du, Ying; Li, Yang; Wang, Shuo; Zhang, Zhinan

    2016-07-01

    Tribological tests play an important role on the evaluation of long-term bio-tribological performances of prosthetic materials for commercial fabrication. Those tests focus on the motion simulation of a real joint in vitro with only normal loads and constant velocities, which are far from the real friction behavior of human joints characterized with variable loads and multiple directions. In order to accurately obtain the bio-tribological performances of artificial joint materials, a tribological tester with a miniature four-station tribological system is proposed with four distinctive features. Firstly, comparability and repeatability of a test are ensured by four equal stations of the tester. Secondly, cross-linked scratch between tribo-pairs of human joints can be simulated by using a gear-rack meshing mechanism to produce composite motions. With this mechanism, the friction tracks can be designed by varying reciprocating and rotating speeds. Thirdly, variable loading system is realized by using a ball-screw mechanism driven by a stepper motor, by which loads under different gaits during walking are simulated. Fourthly, dynamic friction force and normal load can be measured simultaneously. The verifications of the performances of the developed tester show that the variable frictional tracks can produce different wear debris compared with one-directional tracks, and the accuracy of loading and friction force is within ±5%. Thus the high consistency among different stations can be obtained. Practically, the proposed tester system could provide more comprehensive and accurate bio-tribological evaluations for prosthetic materials.

  20. Can self-testing increase HIV testing among men who have sex with men: A systematic review and meta-analysis.

    PubMed

    Zhang, Ci; Li, Xianhong; Brecht, Mary-Lynn; Koniak-Griffin, Deborah

    2017-01-01

    Globally, four out of ten individuals living with HIV have not been tested for HIV. Testing is especially important for men who have sex with men (MSM), among whom an increasing HIV epidemic has been identified in many regions of the world. As a supplement to site-based HIV testing services, HIV self-testing (HIVST) provides a promising approach to promote HIV testing. However, evidence is scattered and not well-summarized on the effect of HIVST to improve HIV testing behaviors, especially for MSM. Seven databases (PubMed, Web of Science, Cochrane Library, PsycINFO, CINAHL Plus, WanFang, and China National Knowledge Internet) and conference abstracts from six HIV/sexually transmitted infections conferences were searched from January 2000-April 2017. Of 1,694 records retrieved, 23 studies were identified, 9 conducted in resource-limited countries and 14 in high-income countries. The pooled results showed that HIVST increased HIV test frequency for MSM by one additional test in a 6-month period (mean difference = 0.88 [95% CI 0.52-1.24]). The pooled proportion of first-time testers among those who took HIVST was 18.7% (95% CI: 9.9-32.4) globally, with a rate 3.32 times higher in resource-limited country settings (32.9% [95% CI: 21.3-47.6]) than in high-income countries (9.9% [95% CI: 7.4-13.8]). The pooled proportions included non-recent testers, 32.9% (95% CI: 28.1-38.3); ever or currently married MSM, 16.7% (95% CI: 14.5-19.4); and HIV positive men, 3.8% (95% CI: 2.0-5.7) globally; 6.5% [95% CI: 0.38-12.3] in resource-limited country settings; and 2.9% [95% CI: 2.0-5.0] in high-income countries). The rates reported for linkage to care ranged from 31.3% to 100%. HIVST could increase HIV testing frequency and potentially have capacity equivalent to that of site-based HIV testing services to reach first-time, delayed, married, and HIV-infected testers among MSM and link them to medical care. However, more rigorous study designs are needed to explore the specific self-testing approach (oral-fluid based or finger-prick based) on improving HIV testing for MSM in different social and economic settings.

  1. Resting state neural networks for visual Chinese word processing in Chinese adults and children.

    PubMed

    Li, Ling; Liu, Jiangang; Chen, Feiyan; Feng, Lu; Li, Hong; Tian, Jie; Lee, Kang

    2013-07-01

    This study examined the resting state neural networks for visual Chinese word processing in Chinese children and adults. Both the functional connectivity (FC) and amplitude of low frequency fluctuation (ALFF) approaches were used to analyze the fMRI data collected when Chinese participants were not engaged in any specific explicit tasks. We correlated time series extracted from the visual word form area (VWFA) with those in other regions in the brain. We also performed ALFF analysis in the resting state FC networks. The FC results revealed that, regarding the functionally connected brain regions, there exist similar intrinsically organized resting state networks for visual Chinese word processing in adults and children, suggesting that such networks may already be functional after 3-4 years of informal exposure to reading plus 3-4 years formal schooling. The ALFF results revealed that children appear to recruit more neural resources than adults in generally reading-irrelevant brain regions. Differences between child and adult ALFF results suggest that children's intrinsic word processing network during the resting state, though similar in functional connectivity, is still undergoing development. Further exposure to visual words and experience with reading are needed for children to develop a mature intrinsic network for word processing. The developmental course of the intrinsically organized word processing network may parallel that of the explicit word processing network. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Cortical visual dysfunction in children: a clinical study.

    PubMed

    Dutton, G; Ballantyne, J; Boyd, G; Bradnam, M; Day, R; McCulloch, D; Mackie, R; Phillips, S; Saunders, K

    1996-01-01

    Damage to the cerebral cortex was responsible for impairment in vision in 90 of 130 consecutive children referred to the Vision Assessment Clinic in Glasgow. Cortical blindness was seen in 16 children. Only 2 were mobile, but both showed evidence of navigational blind-sight. Cortical visual impairment, in which it was possible to estimate visual acuity but generalised severe brain damage precluded estimation of cognitive visual function, was observed in 9 children. Complex disorders of cognitive vision were seen in 20 children. These could be divided into five categories and involved impairment of: (1) recognition, (2) orientation, (3) depth perception, (4) perception of movement and (5) simultaneous perception. These disorders were observed in a variety of combinations. The remaining children showed evidence of reduced visual acuity and/ or visual field loss, but without detectable disorders of congnitive visual function. Early recognition of disorders of cognitive vision is required if active training and remediation are to be implemented.

  3. Trends in HIV testing, prevalence among first-time testers, and incidence in most-at-risk populations in Spain: the EPI-VIH Study, 2000 to 2009.

    PubMed

    Diez, M; Bleda, M J; Varela, J R; Ordonana, J; Azpiri, M A; Vall, M; Santos, C; Viloria, L; de Armas, C; Urena, J M; Trullen, J; Pueyo, I; Martinez, B; Puerta, T; Vera, M; Sanz, I; Junquera, M L; Landa, M C; Martinez, E; Camara, M M; Belda, J; Bru, F J; Diaz, A

    2014-11-27

    During 2000 to 2009, data on people undergoing HIV testing and on those newly diagnosed with HIV were collected in a network of 20 Spanish clinics specialising in sexually transmitted infections and/or HIV testing and counselling. The number of tests performed, overall and disaggregated by different variables, was obtained. HIV prevalence among first-time testers and HIV incidence among repeat testers were calculated. To evaluate trends, joinpoint regression models were fitted. In total, 236,939 HIV tests were performed for 165,745 individuals. Overall HIV prevalence among persons seeking HIV testing was 2.5% (95% CI: 2.4 to 2.6). Prevalence was highest in male sex workers who had sex with other men (19.0% (95% CI: 16.7 to 21.4)) and was lowest in female sex workers (0.8% (95% CI: 0.7 to 0.9)). Significant trends in prevalence were observed in men who have sex with men (MSM) (increasing) and heterosexual individuals (decreasing). The incidence analysis included 30,679 persons, 64,104 person-years (py) of follow-up and 642 seroconversions. The overall incidence rate (IR) was 1.0/100 py (95% CI: 0.9/100 to 1.1/100). Incidence was significantly higher in men and transgender females than in women (1.8/100 py (95% CI: 1.6 to 1.9), 1.2/100 py (95% CI: 0.5 to 2.8) and 0.1/100 py (95% CI: 0.09 to 0.2) respectively) and increased with age until 35–39 years. IRs in MSM and people who inject drugs were significantly greater than in heterosexual individuals (2.5/100 py (95% CI: 2.3 to 2.7), 1.6/100 py (95% CI: 1.1 to 2.2) and 0.1/100 py (95% CI: 0.09 to 0.2) respectively), and an upward trend was observed in MSM. Our results call for HIV prevention to be reinforced in MSM and transgender women in Spain.

  4. Effects of visual attention on chromatic and achromatic detection sensitivities.

    PubMed

    Uchikawa, Keiji; Sato, Masayuki; Kuwamura, Keiko

    2014-05-01

    Visual attention has a significant effect on various visual functions, such as response time, detection and discrimination sensitivity, and color appearance. It has been suggested that visual attention may affect visual functions in the early visual pathways. In this study we examined selective effects of visual attention on sensitivities of the chromatic and achromatic pathways to clarify whether visual attention modifies responses in the early visual system. We used a dual task paradigm in which the observer detected a peripheral test stimulus presented at 4 deg eccentricities while the observer concurrently carried out an attention task in the central visual field. In experiment 1, it was confirmed that peripheral spectral sensitivities were reduced more for short and long wavelengths than for middle wavelengths with the central attention task so that the spectral sensitivity function changed its shape by visual attention. This indicated that visual attention affected the chromatic response more strongly than the achromatic response. In experiment 2 it was obtained that the detection thresholds increased in greater degrees in the red-green and yellow-blue chromatic directions than in the white-black achromatic direction in the dual task condition. In experiment 3 we showed that the peripheral threshold elevations depended on the combination of color-directions of the central and peripheral stimuli. Since the chromatic and achromatic responses were separately processed in the early visual pathways, the present results provided additional evidence that visual attention affects responses in the early visual pathways.

  5. Functional specialization and generalization for grouping of stimuli based on colour and motion

    PubMed Central

    Zeki, Semir; Stutters, Jonathan

    2013-01-01

    This study was undertaken to learn whether the principle of functional specialization that is evident at the level of the prestriate visual cortex extends to areas that are involved in grouping visual stimuli according to attribute, and specifically according to colour and motion. Subjects viewed, in an fMRI scanner, visual stimuli composed of moving dots, which could be either coloured or achromatic; in some stimuli the moving coloured dots were randomly distributed or moved in random directions; in others, some of the moving dots were grouped together according to colour or to direction of motion, with the number of groupings varying from 1 to 3. Increased activation was observed in area V4 in response to colour grouping and in V5 in response to motion grouping while both groupings led to activity in separate though contiguous compartments within the intraparietal cortex. The activity in all the above areas was parametrically related to the number of groupings, as was the prominent activity in Crus I of the cerebellum where the activity resulting from the two types of grouping overlapped. This suggests (a) that, the specialized visual areas of the prestriate cortex have functions beyond the processing of visual signals according to attribute, namely that of grouping signals according to colour (V4) or motion (V5); (b) that the functional separation evident in visual cortical areas devoted to motion and colour, respectively, is maintained at the level of parietal cortex, at least as far as grouping according to attribute is concerned; and (c) that, by contrast, this grouping-related functional segregation is not maintained at the level of the cerebellum. PMID:23415950

  6. What motivates use of community-based human immunodeficiency virus testing in rural South Africa?

    PubMed Central

    Upadhya, Devesh; Moll, Anthony P; Brooks, Ralph P; Friedland, Gerald; Shenoi, Sheela V

    2016-01-01

    Despite substantial progress in implementing human immunodeficiency virus testing, challenges remain in achieving widespread uptake particularly in rural resource-limited settings. We sought to understand motivations for human immunodeficiency virus testing in a community-based human immunodeficiency virus testing programme in rural South Africa. We conducted a questionnaire survey in participants undergoing voluntary human immunodeficiency virus testing within an ongoing community-based integrated human immunodeficiency virus/TB intensive case finding programme at congregate rural settings. Participants responded to a six-item non-mutually exclusive motivations survey which included the topics of feeling ill, recent HV exposure, risky lifestyle, illness in a family member, and pregnancy. Among 2068 respondents completing the survey, 1393 (67.4%) were women, median age was 40 years (IQR 19–56), and 1235 (59.7%) were first time testers. Among all testers, 142 (6.9%) were human immunodeficiency virus-positive with median CD4 count 346 (IQR 218–542). Community-based testing for human immunodeficiency virus is acceptable and meets the needs of community members in rural South Africa. Motivations for human immunodeficiency virus testing at the community level are complex and differ according to gender, age, site of community testing, and human immunodeficiency virus status. These differences can be utilised to improve the focus and yield of community-based human immunodeficiency virus screening. PMID:26134323

  7. Structural and functional changes across the visual cortex of a patient with visual form agnosia.

    PubMed

    Bridge, Holly; Thomas, Owen M; Minini, Loredana; Cavina-Pratesi, Cristiana; Milner, A David; Parker, Andrew J

    2013-07-31

    Loss of shape recognition in visual-form agnosia occurs without equivalent losses in the use of vision to guide actions, providing support for the hypothesis of two visual systems (for "perception" and "action"). The human individual DF received a toxic exposure to carbon monoxide some years ago, which resulted in a persisting visual-form agnosia that has been extensively characterized at the behavioral level. We conducted a detailed high-resolution MRI study of DF's cortex, combining structural and functional measurements. We present the first accurate quantification of the changes in thickness across DF's occipital cortex, finding the most substantial loss in the lateral occipital cortex (LOC). There are reduced white matter connections between LOC and other areas. Functional measures show pockets of activity that survive within structurally damaged areas. The topographic mapping of visual areas showed that ordered retinotopic maps were evident for DF in the ventral portions of visual cortical areas V1, V2, V3, and hV4. Although V1 shows evidence of topographic order in its dorsal portion, such maps could not be found in the dorsal parts of V2 and V3. We conclude that it is not possible to understand fully the deficits in object perception in visual-form agnosia without the exploitation of both structural and functional measurements. Our results also highlight for DF the cortical routes through which visual information is able to pass to support her well-documented abilities to use visual information to guide actions.

  8. Relations of Preschoolers' Visual-Motor and Object Manipulation Skills with Executive Function and Social Behavior

    ERIC Educational Resources Information Center

    MacDonald, Megan; Lipscomb, Shannon; McClelland, Megan M.; Duncan, Rob; Becker, Derek; Anderson, Kim; Kile, Molly

    2016-01-01

    Purpose: The purpose of this article was to examine specific linkages between early visual-motor integration skills and executive function, as well as between early object manipulation skills and social behaviors in the classroom during the preschool year. Method: Ninety-two children aged 3 to 5 years old (M[subscript age] = 4.31 years) were…

  9. Functional localization of the human color center by decreased water displacement using diffusion-weighted fMRI.

    PubMed

    Williams, Rebecca J; Reutens, David C; Hocking, Julia

    2015-11-01

    Decreased water displacement following increased neural activity has been observed using diffusion-weighted functional MRI (DfMRI) at high b-values. The physiological mechanisms underlying the diffusion signal change may be unique from the standard blood oxygenation level-dependent (BOLD) contrast and closer to the source of neural activity. Whether DfMRI reflects neural activity more directly than BOLD outside the primary cerebral regions remains unclear. Colored and achromatic Mondrian visual stimuli were statistically contrasted to functionally localize the human color center Area V4 in neurologically intact adults. Spatial and temporal properties of DfMRI and BOLD activation were examined across regions of the visual cortex. At the individual level, DfMRI activation patterns showed greater spatial specificity to V4 than BOLD. The BOLD activation patterns were more prominent in the primary visual cortex than DfMRI, where activation was localized to the ventral temporal lobe. Temporally, the diffusion signal change in V4 and V1 both preceded the corresponding hemodynamic response, however the early diffusion signal change was more evident in V1. DfMRI may be of use in imaging applications implementing cognitive subtraction paradigms, and where highly precise individual functional localization is required.

  10. Inducible error-prone repair in B. subtilis. Final report, September 1, 1979-June 30, 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yasbin, R. E.

    1981-06-01

    The research performed under this contract has been concentrated on the relationship between inducible DNA repair systems, mutagenesis and the competent state in the gram positive bacterium Bacillus subtilis. The following results have been obtained from this research: (1) competent Bacillus subtilis cells have been developed into a sensitive tester system for carcinogens; (2) competent B. subtilis cells have an efficient excision-repair system, however, this system will not function on bacteriophage DNA taken into the cell via the process of transfection; (3) DNA polymerase III is essential in the mechanism of the process of W-reactivation; (4) B. subtilis strains curedmore » of their defective prophages have been isolated and are now being developed for gene cloning systems; (5) protoplasts of B. subtilis have been shown capable of acquiring DNA repair enzymes (i.e., enzyme therapy); and (6) a plasmid was characterized which enhanced inducible error-prone repair in a gram positive organism.« less

  11. Cryogenic gear technology for an orbital transfer vehicle engine and tester design

    NASA Technical Reports Server (NTRS)

    Calandra, M.; Duncan, G.

    1986-01-01

    Technology available for gears used in advanced Orbital Transfer Vehicle rocket engines and the design of a cryogenic adapted tester used for evaluating advanced gears are presented. The only high-speed, unlubricated gears currently in cryogenic service are used in the RL10 rocket engine turbomachinery. Advanced rocket engine gear systems experience operational load conditions and rotational speed that are beyond current experience levels. The work under this task consisted of a technology assessment and requirements definition followed by design of a self-contained portable cryogenic adapted gear test rig system.

  12. Reducing software security risk through an integrated approach

    NASA Technical Reports Server (NTRS)

    Gilliam, D.; Powell, J.; Kelly, J.; Bishop, M.

    2001-01-01

    The fourth quarter delivery, FY'01 for this RTOP is a Property-Based Testing (PBT), 'Tester's Assistant' (TA). The TA tool is to be used to check compiled and pre-compiled code for potential security weaknesses that could be exploited by hackers. The TA Instrumenter, implemented mostly in C++ (with a small part in Java), parsels two types of files: Java and TASPEC. Security properties to be checked are written in TASPEC. The Instrumenter is used in conjunction with the Tester's Assistant Specification (TASpec)execution monitor to verify the security properties of a given program.

  13. Ultrasonic and optical evaluation of surgical implant materials and devices. A durability study of pericardial bioprostheses

    NASA Technical Reports Server (NTRS)

    Schuster, P. R.

    1984-01-01

    Laser Doppler Anemometry (LDA) and accelerated fatigue testing were used in an attempt to assess the durability of two cardiac value bioprostheses. The LDA system was used to monitor the function of the cardiac valves over time. This was done through flow characterization in an aortic flow chamber, designed to closely simulate in vivo conditions, both in the near vicinity (sinuses of valsalva region) and also somewhat downstream (aortic region) from the values. The accelerated fatigue tester was operated by opening and closing the valves at a rate of 1300 R.P.M., about 18 x the normal rate. The results from the two test valves indicate a definite change in the flow characteristics downstream from the valve after certain accelerated test intervals. The high velocity cross-sectional flow area seems to increase over time in use, causing a decrease in the peak velocity. The tissue became more flaccid in certain areas, and tears were apparent at about 9.4 million cycles for the Ionescu-Shiley valve and at 24 million cycles for the Carpentier-Edwards valve. The use of Doppler ultrasound as a technique for monitoring the function of bioprostheses over time in vivo is also discussed.

  14. HIV infection among people of foreign origin voluntarily tested in Spain. A comparison with national subjects

    PubMed Central

    The, E

    2002-01-01

    Objectives: To describe exposure categories and HIV prevalence among subjects voluntarily tested in Spain by country of origin. Methods: HIV prevalence and exposure categories were compared between national and non-Spanish subjects voluntarily tested in 18 sexually transmitted disease/HIV testing clinics from 16 Spanish cities in 2000. Results: Of 8861 testers, 2810 (31.7%) came from foreign countries; 73.1% from Latin America, 9.1% from western Europe, 6.2% from central/eastern Europe, 4.4% from northern Africa, and 4.2% from sub-Sahara Africa. Among women from Latin America, 78% were sex workers compared to 5.5% Spanish women. HIV infection was diagnosed in 170 persons, 34.7% from foreign countries. HIV prevalence for Spanish subjects (23% for men and 1.0% for women) was significantly different from men and women from Latin America (11.3% and 0.3% respectively), Sub-Saharan Africa (9.1% and 7.5% respectively), and women from the north of Africa (11.8%). Compared with Spaniards, analyses of persons of the same exposure category showed higher HIV prevalence in men who had sex with men from Latin America (odds ratio: 4.1; 95% CI: 2.4–6.9), heterosexual men from sub-Sahara Africa (OR: 19.3; 95% CI: 6.4–58.0), and Latin America (OR: 9.4; 95% CI: 3.4–25.9), heterosexual women from sub-Sahara Africa (OR: 16.9; 95% CI: 3.5–82.4) and from northern Africa (OR: 15.3; 95% CI: 3.2–73.2). Conclusions: An important proportion of HIV testers from these clinics came from foreign countries and some groups showed a high prevalence of HIV infection. Specific prevention and testing programmes adapted to the needs of migrants in Spain should be developed. PMID:12181461

  15. Quality of Vision in Eyes With Epiphora Undergoing Lacrimal Passage Intubation.

    PubMed

    Koh, Shizuka; Inoue, Yasushi; Ochi, Shintaro; Takai, Yoshihiro; Maeda, Naoyuki; Nishida, Kohji

    2017-09-01

    To investigate visual function and optical quality in eyes with epiphora undergoing lacrimal passage intubation. Prospective case series. Thirty-four eyes of 30 patients with lacrimal passage obstruction were enrolled. Before and 1 month after lacrimal passage intubation, functional visual acuity (FVA), higher-order aberrations (HOAs), lower tear meniscus, and tear clearance were assessed. An FVA measurement system was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio, and blink frequency were obtained. Sequential ocular HOAs were measured for 10 seconds after the blink using a wavefront sensor. Aberration data were analyzed in the central 4 mm for coma-like, spherical-like, and total HOAs. Fluctuation and stability indices of the total HOAs over time were calculated. Lower tear meniscus was assessed by anterior segment optical coherence tomography. After lacrimal passage intubation, visual function significantly improved, as indicated by improved FVA (P = .003) and visual maintenance ratio (P < .001). Blink frequency decreased significantly after treatment (P = .01). Optical quality significantly improved, as indicated by a decrease in coma-like aberrations (P = .003), spherical-like aberrations (P = .018), and total HOAs (P = .001). Stability index increased (P < .001) and fluctuation index decreased (P = .019), and tear meniscus dimension decreased (P < .001). Lacrimal passage intubation for eyes with epiphora significantly improved visual function and optical quality via patency of the lacrimal passage. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.

    PubMed

    Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L

    2012-04-01

    Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. The Participation Scale: measuring a key concept in public health.

    PubMed

    van Brakel, Wim H; Anderson, Alison M; Mutatkar, R K; Bakirtzief, Zoica; Nicholls, Peter G; Raju, M S; Das-Pattanayak, Robert K

    2006-02-28

    To develop a scale to measure (social) participation for use in rehabilitation, stigma reduction and social integration programmes. A scale development study was carried out in Nepal, India and Brazil using standard methods. The instrument was to be based on the Participation domains of the International Classification of Functioning, Disability and Health (ICF), be cross-cultural in nature and assess client-perceived participation. Respondents rated their participation in comparison with a "peer", defined as "someone similar to the respondent in all respects except for the disease or disability". An 18-item instrument was developed in seven languages. Crohnbach's alpha was 0.92, intra-tester stability 0.83 and inter-tester reliability 0.80. Discrimination between controls and clients was good at a Participation Score threshold of 12. Responsiveness after a "life change" was according to expectation. The Participation Scale is reliable and valid to measure client-perceived participation in people affected by leprosy or disability. It is expected to be valid in other (stigmatised) conditions also, but this needs confirmation. The scale allows collection of participation data and impact assessment of interventions to improve social participation. Such data may be compared between clients, interventions and programmes. The scale is suitable for use in institutions, but also at the peripheral level.

  18. Characterizing the transplanar and in-plane water transport of textiles with gravimetric and image analysis technique: Spontaneous Uptake Water Transport Tester

    PubMed Central

    Tang, K. P. M.; Wu, Y. S.; Chau, K. H.; Kan, C. W.; Fan, J. T.

    2015-01-01

    Water absorption and transport property of textiles is important since it affects wear comfort, efficiency of treatment and functionality of product. This paper introduces an accurate and reliable measurement tester, which is based on gravimetric and image analysis technique, for characterising the transplanar and in-plane wicking property of fabrics. The uniqueness of this instrument is that it is able to directly measure the water absorption amount in real-time, monitor the direction of water transport and estimate the amount of water left on skin when sweating. Throughout the experiment, water supply is continuous which simulates profuse sweating. Testing automation could even minimise variation caused by subjective manipulation, thus enhancing testing accuracy. This instrument is versatile in terms of the fabrics could be tested. A series of shirting fabrics made by different fabric structure and yarn were investigated and the results show that the proposed method has high sensitivity in differentiating fabrics with varying geometrical differences. Fabrics with known hydrophobicity were additionally tested to examine the sensitivity of the instrument. This instrument also demonstrates the flexibility to test on high performance moisture management fabrics and these fabrics were found to have excellent transplanar and in-plane wicking properties. PMID:25875329

  19. Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema.

    PubMed

    Hudson, C; Flanagan, J G; Turner, G S; Chen, H C; Young, L B; McLeod, D

    2003-04-01

    To correlate change of an oedema index derived by scanning laser tomography with change of visual function in patients undergoing grid laser photocoagulation for clinically significant diabetic macular oedema (DMO). The sample comprised 24 diabetic patients with retinal thickening within 500 micro m of the fovea. Inclusion criteria included a logMAR visual acuity of 0.25, or better. Patients were assessed twice before a single session of grid laser treatment and within 1 week of, and at 1, 2, 4, and 12 weeks after, treatment. At each visit, patients underwent logMAR visual acuity, conventional and short wavelength automated perimetry (SWAP), and scanning laser tomography. Each visual function parameter was correlated with the mean oedema index. The mean oedema index represented the z-profile signal width divided by the maximum reflectance intensity (arbitrary units). A Pearson correlation coefficient (Bonferroni corrected) was undertaken on the data set of each patient. 13 patients exhibited significant correlation of the mean oedema index and at least one measure of visual function for the 10 degrees x 10 degrees scan field while 10 patients correlated for the 20 degrees x 20 degrees scan field. Seven patients demonstrated correlation for both scan fields. Laser photocoagulation typically resulted in an immediate loss of perimetric sensitivity whereas the oedema index changed over a period of weeks. Localised oedema did not impact upon visual acuity or letter contrast sensitivity when situated extrafoveally. Correlation of change of the oedema index and of visual function following grid laser photocoagulation was not found in all patients. An absence of correlation can be explained by the localised distribution of DMO in this sample of patients, as well as by differences in the time course of change of the oedema index and visual function. The study has objectively documented change in the magnitude and distribution of DMO following grid laser treatment and has established the relation of this change to the change in visual function.

  20. [Effects on visual functions following several hours' usage of a head mounted display].

    PubMed

    Hara, N; Ukai, K; Ishikawa, S; Takagi, M; Bando, T; Oyamada, H

    1996-07-01

    We investigated the effects of viewing video movies with a head-mounted display (HMD) for 4 to 6 hours on visual functions such as refraction, visual acuity, and accommodation-vergence system. Two or three video movies were watched without any breaks by 13 normal volunteers (age: 22 approximately 40). Measurements were made of (1) objective and subjective refraction, (2) corrected visual acuity, (3) tonic level and step response of accommodation with a computer-assisted infrared optometer, and (4) near and far phorias and AC/A ratio. Significant transient myopia was found following 4 hours' viewing, but not following 6 hours' viewing. Scrutinizing individual data, myopia was consistently found in some subjects, and hyperopia in others. We presumed that many subjects might have been influenced by initial instrumental myopia when they adjusted the focus by using the mechanism built in the HMD. No significant change was observed in any other examination. However, there was a tendency for the AC/A ratio to change after a short time, and then to recover to its original value. Based on the results in this study, it appears that some changes in accommodation and vergence systems are caused by viewing video movies with the HMD. Although the amount of changes was within normal physiological variation in this study, the possibility still remains that usage for a longer time may lead to other changes in visual function. Care is also necessary when using the HMD in subjects with subclinical problems.

  1. MC-TESTER: a universal tool for comparisons of Monte Carlo predictions for particle decays in high energy physics

    NASA Astrophysics Data System (ADS)

    Golonka, P.; Pierzchała, T.; Waş, Z.

    2004-02-01

    Theoretical predictions in high energy physics are routinely provided in the form of Monte Carlo generators. Comparisons of predictions from different programs and/or different initialization set-ups are often necessary. MC-TESTER can be used for such tests of decays of intermediate states (particles or resonances) in a semi-automated way. Our test consists of two steps. Different Monte Carlo programs are run; events with decays of a chosen particle are searched, decay trees are analyzed and appropriate information is stored. Then, at the analysis step, a list of all found decay modes is defined and branching ratios are calculated for both runs. Histograms of all scalar Lorentz-invariant masses constructed from the decay products are plotted and compared for each decay mode found in both runs. For each plot a measure of the difference of the distributions is calculated and its maximal value over all histograms for each decay channel is printed in a summary table. As an example of MC-TESTER application, we include a test with the τ lepton decay Monte Carlo generators, TAUOLA and PYTHIA. The HEPEVT (or LUJETS) common block is used as exclusive source of information on the generated events. Program summaryTitle of the program:MC-TESTER, version 1.1 Catalogue identifier: ADSM Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSM Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Computer: PC, two Intel Xeon 2.0 GHz processors, 512MB RAM Operating system: Linux Red Hat 6.1, 7.2, and also 8.0 Programming language used:C++, FORTRAN77: gcc 2.96 or 2.95.2 (also 3.2) compiler suite with g++ and g77 Size of the package: 7.3 MB directory including example programs (2 MB compressed distribution archive), without ROOT libraries (additional 43 MB). No. of bytes in distributed program, including test data, etc.: 2 024 425 Distribution format: tar gzip file Additional disk space required: Depends on the analyzed particle: 40 MB in the case of τ lepton decays (30 decay channels, 594 histograms, 82-pages booklet). Keywords: particle physics, decay simulation, Monte Carlo methods, invariant mass distributions, programs comparison Nature of the physical problem: The decays of individual particles are well defined modules of a typical Monte Carlo program chain in high energy physics. A fast, semi-automatic way of comparing results from different programs is often desirable, for the development of new programs, to check correctness of the installations or for discussion of uncertainties. Method of solution: A typical HEP Monte Carlo program stores the generated events in the event records such as HEPEVT or PYJETS. MC-TESTER scans, event by event, the contents of the record and searches for the decays of the particle under study. The list of the found decay modes is successively incremented and histograms of all invariant masses which can be calculated from the momenta of the particle decay products are defined and filled. The outputs from the two runs of distinct programs can be later compared. A booklet of comparisons is created: for every decay channel, all histograms present in the two outputs are plotted and parameter quantifying shape difference is calculated. Its maximum over every decay channel is printed in the summary table. Restrictions on the complexity of the problem: For a list of limitations see Section 6. Typical running time: Varies substantially with the analyzed decay particle. On a PC/Linux with 2.0 GHz processors MC-TESTER increases the run time of the τ-lepton Monte Carlo program TAUOLA by 4.0 seconds for every 100 000 analyzed events (generation itself takes 26 seconds). The analysis step takes 13 seconds; ? processing takes additionally 10 seconds. Generation step runs may be executed simultaneously on multi-processor machines. Accessibility: web page: http://cern.ch/Piotr.Golonka/MC/MC-TESTER e-mails: Piotr.Golonka@CERN.CH, T.Pierzchala@friend.phys.us.edu.pl, Zbigniew.Was@CERN.CH.

  2. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    PubMed

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the individual subsystem scores ranged from 0.72 to 0.89. The CVME (N = 70) of the BESTest total score was 4.1%. The CVME for the subsystem scores ranged from 5.0% to 10.7%. MDC (N = 70) for the BESTest total score at the 95% CI was 7.6%, or 8.2 points. MDC at the 95% CI for subsystem scores ranged from 11.7% to 19.0% (2.1-3.4 points). Results demonstrated generally good to excellent interrater and test-retest reliability in both the BESTest total and subsystem scores with community-dwelling older adults. The BESTest total and individual subsystem scores demonstrate good to excellent interrater and test-retest reliability with community-dwelling older adults. A change of 7.6% (8.2 points) or more in the BESTest total and a percentage change ranged from 11.7% to 19.0% (2.1-3.4 points) in the subsystem scores are suggested for clinicians to be 95% confident of true change when evaluating change in this population.

  3. Use of GetCheckedOnline, a Comprehensive Web-based Testing Service for Sexually Transmitted and Blood-Borne Infections.

    PubMed

    Gilbert, Mark; Salway, Travis; Haag, Devon; Fairley, Christopher K; Wong, Jason; Grennan, Troy; Uddin, Zhaida; Buchner, Christopher S; Wong, Tom; Krajden, Mel; Tyndall, Mark; Shoveller, Jean; Ogilvie, Gina

    2017-03-20

    The British Columbia Centre for Disease Control implemented a comprehensive Web-based testing service GetCheckedOnline (GCO) in September 2014 in Vancouver, Canada. GCO's objectives are to increase testing for sexually transmitted and blood-borne infections (STBBIs), reach high-prevalence populations facing testing barriers, and increase clinical STI service capacity. GCO was promoted through email invitations to provincial STI clinic clients, access codes to clients unable to access immediate clinic-based testing (deferred testers), and a campaign to gay, bisexual, and other men who have sex with men (MSM). The objective of the study was to report on characteristics of GCO users, use and test outcomes (overall and by promotional strategy) during this pilot phase. We used GCO program data, website metrics, and provincial STI clinic records to describe temporal trends, progression through the service pathway, and demographic, risk, and testing outcomes for individuals creating GCO accounts during the first 15 months of implementation. Of 868 clients creating accounts, 318 (36.6%) submitted specimens, of whom 96 (30.2%) tested more than once and 10 (3.1%) had a positive STI diagnosis. The proportion of clients submitting specimens increased steadily over the course of the pilot phase following introduction of deferred tester codes. Clients were diverse with respect to age, gender, and ethnicity, although youth and individuals of nonwhite ethnicity were underrepresented. Of the 506 clients completing risk assessments, 215 (42.5%) were MSM, 89 (17.6%) were symptomatic, 47 (9.3%) were STI contacts, 232 (45.8%) reported condomless sex, 146 (28.9%) reported ≥4 partners in the past 3 months, and 76 (15.0%) reported a recent STI. A total of 63 (12.5%) GCO clients were testing for the first time. For 868 accounts created, 337 (38.8%) were by clinic invitations (0 diagnoses), 298 (34.3%) were by deferred testers (6 diagnoses), 194 (22.4%) were by promotional campaign (3 diagnoses), and 39 (4.5%) were by other means (1 diagnosis). Our evaluation suggests that GCO is an acceptable and feasible approach to engage individuals in testing. Use by first-time testers, repeated use, and STI diagnosis of individuals unable to access immediate clinic-based testing suggest GCO may facilitate uptake of STBBI testing and earlier diagnosis. Use by MSM and individuals reporting sexual risk suggests GCO may reach populations with a higher risk of STI. Motivation to test (eg, unable to access clinical services immediately) appears a key factor underlying GCO use. These findings identify areas for refinement of the testing model, further promotion, and future research (including understanding reasons for drop-off through the service pathway and more comprehensive evaluation of effectiveness). Increased uptake and diagnosis corresponding with expansion of the service within British Columbia will permit future evaluation of this service across varying populations and settings. ©Mark Gilbert, Travis Salway, Devon Haag, Christopher K Fairley, Jason Wong, Troy Grennan, Zhaida Uddin, Christopher S Buchner, Tom Wong, Mel Krajden, Mark Tyndall, Jean Shoveller, Gina Ogilvie. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 20.03.2017.

  4. Attention biases visual activity in visual short-term memory.

    PubMed

    Kuo, Bo-Cheng; Stokes, Mark G; Murray, Alexandra M; Nobre, Anna Christina

    2014-07-01

    In the current study, we tested whether representations in visual STM (VSTM) can be biased via top-down attentional modulation of visual activity in retinotopically specific locations. We manipulated attention using retrospective cues presented during the retention interval of a VSTM task. Retrospective cues triggered activity in a large-scale network implicated in attentional control and led to retinotopically specific modulation of activity in early visual areas V1-V4. Importantly, shifts of attention during VSTM maintenance were associated with changes in functional connectivity between pFC and retinotopic regions within V4. Our findings provide new insights into top-down control mechanisms that modulate VSTM representations for flexible and goal-directed maintenance of the most relevant memoranda.

  5. Patient perceptions and expectations of an anticoagulation service: a quantitative comparison study of clinic-based testers and patient self-testers.

    PubMed

    Money, Arthur G; Barnett, Julie; Kuljis, Jasna; Duffin, Debbie

    2015-12-01

    Government initiatives see the provision of technology-assisted self-care as one of the key areas in which there is capacity for improving quality of care whilst reducing costs. However, levels of patient engagement in self-testing and management (STM) remain low. Little emphasis has been placed on understanding the patients' perspectives of the reasons for this limited engagement. Typically, patient engagement in STM is achieved via the provision of patient education programmes, which aim to enable patients to make the changes necessary to become competent self-carers. However, placing the onus to change on the individual patient is unrealistic. If levels of patient engagement are to be improved, patient needs and expectations of clinical services must be better understood and service provision must be adapted accordingly. Explore patient perceptions and expectations of clinical service provision and their views of having and making choices about care. Participants [N = 191, 103 patient self-tester managers (PSTMs) and 87 clinic-based testers (CBTs)] completed the SERVQUAL and ChQ instruments to capture perspectives on service quality and choice, respectively. A comparative statistical analysis explored the similarities and differences between PSTMs' and CBTs' responses. Clinic-based testers' perceptions of service quality were significantly more positive than PSTMs', as were their expectations of the 'tangible' aspects of service delivery. PSTMs' expectations of service quality were significantly higher than their perceptions. PSTMs attributed significantly more value to making choices compared with CBTs. To close the gap between PSTMs expectations and perceptions of service quality and better cater for their choice preferences, service providers may benefit from taking into account the following practice considerations: maintain frequent, timely, personalised and direct interactions with PSTMs; prioritise investment in resources to facilitate patient/practitioner interaction over tangible facilities; ensure that PSTMs are given the opportunity to make choices about their care. © 2015 The Authors. Scandinavian Journal of Caring Sciences published by John Wiley & Sons Ltd on behalf of Nordic College of Caring Science.

  6. Exploring Operational Test and Evaluation of Unmanned Aircraft Systems: A Qualitative Case Study

    NASA Astrophysics Data System (ADS)

    Saliceti, Jose A.

    The purpose of this qualitative case study was to explore and identify strategies that may potentially remedy operational test and evaluation procedures used to evaluate Unmanned Aircraft Systems (UAS) technology. The sample for analysis consisted of organizations testing and evaluating UASs (e.g., U.S. Air Force, U.S. Navy, U.S. Army, U.S. Marine Corps, U.S. Coast Guard, and Customs Border Protection). A purposeful sampling technique was used to select 15 subject matter experts in the field of operational test and evaluation of UASs. A questionnaire was provided to participants to construct a descriptive and robust research. Analysis of responses revealed themes related to each research question. Findings revealed operational testers utilized requirements documents to extrapolate measures for testing UAS technology and develop critical operational issues. The requirements documents were (a) developed without the contribution of stakeholders and operational testers, (b) developed with vague or unrealistic measures, and (c) developed without a systematic method to derive requirements from mission tasks. Four approaches are recommended to develop testable operational requirements and assist operational testers: (a) use a mission task analysis tool to derive requirements for mission essential tasks for the system, (b) exercise collaboration among stakeholders and testers to ensure testable operational requirements based on mission tasks, (c) ensure testable measures are used in requirements documents, and (d) create a repository list of critical operational issues by mission areas. The preparation of operational test and evaluation processes for UAS technology is not uniform across testers. The processes in place are not standardized, thus test plan preparation and reporting are different among participants. A standard method to prepare and report UAS technology should be used when preparing and reporting on UAS technology. Using a systematic process, such as mission-based test design, resonated among participants as an analytical method to link UAS mission tasks and measures of performance to the capabilities of the system under test when developing operational test plans. Further research should examine system engineering designs for system requirements traceability matrix of mission tasks and subtasks while using an analysis tool that adequately evaluates UASs with an acceptable level of confidence in the results.

  7. White matter changes linked to visual recovery after nerve decompression

    PubMed Central

    Paul, David A.; Gaffin-Cahn, Elon; Hintz, Eric B.; Adeclat, Giscard J.; Zhu, Tong; Williams, Zoë R.; Vates, G. Edward; Mahon, Bradford Z.

    2015-01-01

    The relationship between the integrity of white matter tracts and cortical function in the human brain remains poorly understood. Here we use a model of reversible white matter injury, compression of the optic chiasm by tumors of the pituitary gland, to study the structural and functional changes that attend spontaneous recovery of cortical function and visual abilities after surgical tumor removal and subsequent decompression of the nerves. We show that compression of the optic chiasm leads to demyelination of the optic tracts, which reverses as quickly as 4 weeks after nerve decompression. Furthermore, variability across patients in the severity of demyelination in the optic tracts predicts visual ability and functional activity in early cortical visual areas, and pre-operative measurements of myelination in the optic tracts predicts the magnitude of visual recovery after surgery. These data indicate that rapid regeneration of myelin in the human brain is a significant component of the normalization of cortical activity, and ultimately the recovery of sensory and cognitive function, after nerve decompression. More generally, our findings demonstrate the utility of diffusion tensor imaging as an in vivo measure of myelination in the human brain. PMID:25504884

  8. Digital Sound Encryption with Logistic Map and Number Theoretic Transform

    NASA Astrophysics Data System (ADS)

    Satria, Yudi; Gabe Rizky, P. H.; Suryadi, MT

    2018-03-01

    Digital sound security has limits on encrypting in Frequency Domain. Number Theoretic Transform based on field (GF 2521 – 1) improve and solve that problem. The algorithm for this sound encryption is based on combination of Chaos function and Number Theoretic Transform. The Chaos function that used in this paper is Logistic Map. The trials and the simulations are conducted by using 5 different digital sound files data tester in Wave File Extension Format and simulated at least 100 times each. The key stream resulted is random with verified by 15 NIST’s randomness test. The key space formed is very big which more than 10469. The processing speed of algorithm for encryption is slightly affected by Number Theoretic Transform.

  9. The impact of visual impairment on self-reported visual functioning in Latinos: The Los Angeles Latino Eye Study.

    PubMed

    Globe, Denise R; Wu, Joanne; Azen, Stanley P; Varma, Rohit

    2004-06-01

    To assess the association between presenting binocular visual acuity (VA) and self-reported visual function as measured by the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). A population-based, prevalence study of eye disease in Latinos 40 years and older residing in La Puente, California (Los Angeles Latino Eye Study [LALES]). Six thousand three hundred fifty-seven Latinos 40 years and older from 6 census tracts in La Puente. All participants completed a standardized interview, including the NEI-VFQ-25 to measure visual functioning, and a detailed eye examination. Two definitions of visual impairment were used: (1) presenting binocular distance VA of 20/40 or worse and (2) presenting binocular distance VA worse than 20/40. Analysis of variance was used to determine any systematic differences in mean NEI-VFQ-25 scores by visual impairment. Regression analyses were completed (1) to determine the association of age, gender, number of systemic comorbidities, depression, and VA with self-reported visual function and (2) to estimate a visual impairment-related difference for each subscale based on differences in VA. The NEI-VFQ-25 scores in persons with visual impairment. Of the 5287 LALES participants with complete NEI-VFQ-25 data, 6.3% (including 20/40) and 4.2% (excluding 20/40) were visually impaired. In the visually impaired participants, the NEI-VFQ-25 subscale scores ranged from 46.2 (General Health) to 93.8 (Color Vision). In the regression model, only VA, depression, and number of comorbidities were significantly associated with all subscale scores (R(2) ranged from 0.09 for Ocular Pain to 0.33 for the composite score). For 9 of 11 subscales, a 5-point change was equivalent to a 1- or 2-line difference in VA. Relationships were similar regardless of the definition of visual impairment. In this population-based study of Latinos, the NEI-VFQ-25 was sensitive to differences in VA. A 5-point difference on the NEI-VFQ-25 seems to be a minimal criterion for a visual impairment-related difference. Self-reported visual function is essentially unchanged if the definition of visual impairment includes or excludes a VA of 20/40.

  10. The Medical Hazards of Flame-Suppressant Atmospheres

    DTIC Science & Technology

    1991-04-19

    the external and middle earcavities. Graph B shows inward distension of the may need to be interrupted or slowed to eardrum produced by higher...experiments were performed by mental function, muscular coordination, military scientists (see ACKNOW- night vision, visual contrast sensitivity, LEDGEMENTS) in...task of muscular posure to change any of the visual coordination was slightly function tests (Luria & Knight, degraded during the first 4 h of 1987). the

  11. Behavioral intention to take up different types of HIV testing among men who have sex with men who were never-testers in Hong Kong.

    PubMed

    Wang, Zixin; Lau, Joseph T F; She, Rui; Ip, Mary; Jiang, Hui; Ho, Shara P Y; Yang, XueYing

    2018-01-01

    Human immunodeficiency virus (HIV) testing is an important global prevention strategy but underutilized by local men who have sex with men (MSM). This study investigated the prevalence of behavioral intention to take up HIV testing (specific or any type), in the next six months among MSM who had not been tested for HIV in the last three years (never-testers) in Hong Kong. The data was based on 141 never-testers of 430 MSM who completed the anonymous baseline telephone survey of an ongoing randomized controlled trial from January 2015 to August 2015. Only 17.7% of them showed strong intention to take up any type of HIV testing in the next six months. Adjusted analysis showed that perceived benefit of HIV testing (adjusted odds ratio [AOR]: 1.29, 95% confidence interval [CI]: 1.01, 1.66), perceived psychological barriers of HIV testing (AOR: 0.85, 95%CI: 0.73, 1.00), and perceived self-efficacy in taking up HIV testing (AOR: 1.28, 95%CI: 1.07, 1.52) were significantly associated with behavioral intention to take up any HIV testing. Perceived cue to action from non-governmental organization staff was positively associated with a marginal p-value of 0.077 (AOR: 2.37, 95%CI: 0.97, 5.77). It is warranted to strengthen perceived benefit, remove psychological barriers, and increase perceived self-efficacy related to HIV testing. Innovative and effective health promotions are greatly needed to increase HIV testing coverage among never-testers.

  12. Motivation and experiences of self-testers regarding tests for cardiovascular risk factors.

    PubMed

    Ickenroth, Martine H P; Grispen, Janaica E J; Ronda, Gaby; Tacken, Marloes; Dinant, Geert-Jan; de Vries, Nanne K; van der Weijden, Trudy

    2014-02-01

    In recent years, self-tests have become increasingly available to the general public, though their value is still being debated. Because these tests are available, consumers should have access to clear information about self-testing. Examining experiences of self-testers could contribute to the development of consumer information. Detailed exploration of consumers' experiences with self-testing for cardiovascular risk factors. Semi-structured interviews with 20 consumers who had performed a self-test for glucose, cholesterol or albuminuria. The main topics of the interviews were reasons for self-testing, performing the self-test, follow-up behaviour and perceived need for information on self-testing. Data were analysed using thematic content analysis. Regarding the reason for self-testing, three types of users were distinguished: those who engaged in self-testing when a test was offered, either with or without previous knowledge about the disease or risk factor, and those who had actively decided to test and had searched for a self-test themselves. Self-testers had generally experienced no problems performing the test or interpreting the result and had considerable confidence in the result. They were easily reassured by a normal result, while an abnormal result did not automatically mean they consulted a doctor. Most participants did not feel the need for more information. Self-testers often perform tests for reassurance, without considering the disadvantages, such as the absence of professional counselling and the risk of false-positive or false-negative results. Consumer information should promote more informed and deliberate choices for self-testing. © 2011 John Wiley & Sons Ltd.

  13. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    PubMed

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (<61% of respondents) were as follows: systemic allergic dermatitis reaction, therapy-resistant dermatitis, morphology consistent with dermatitis, histology consistent with allergic contact dermatitis, and a positive in vitro test to metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.

  14. Pulse electrodeposition of self-lubricating Ni-W/PTFE nanocomposite coatings on mild steel surface

    NASA Astrophysics Data System (ADS)

    Sangeetha, S.; Kalaignan, G. Paruthimal; Anthuvan, J. Tennis

    2015-12-01

    Ni-W/PTFE nanocomposite coatings with various contents of PTFE (polytetafluoroethylene) particles were prepared by pulse current (PC) electrodeposition from the Ni-W plating bath containing self lubricant PTFE particles to be co-deposited. Co-deposited PTFE particulates were uniformly distributed in the Ni-W alloy matrix. The coatings were characterized by Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Analysis (EDAX), X-ray Diffractometry (XRD) and Vicker's micro hardness tester. Tafel Polarization and electrochemical Impedance methods were used to evaluate the corrosion resistance behaviour of the nanocomposite coatings in 3.5% NaCl solution. It was found that, the Ni-W/PTFE nanocomposite coating has better corrosion resistance than the Ni-W alloy coating. Surface roughness and friction coefficient of the coated samples were assessed by Mitutoyo Surftest SJ-310 (ISO1997) and Scratch tester TR-101-M4 respectively. The contact angle (CA) of a water droplet on the surface of nanocomposite coating was measured by Optical Contact Goniometry (OCA 35). These results indicated that, the addition of PTFE in the Ni-W alloy matrix has resulted moderate microhardness, smooth surface, less friction coefficient, excellent water repellency and enhanced corrosion resistance of the nanocomposite coatings.

  15. Insensitivity of visual short-term memory to irrelevant visual information.

    PubMed

    Andrade, Jackie; Kemps, Eva; Werniers, Yves; May, Jon; Szmalec, Arnaud

    2002-07-01

    Several authors have hypothesized that visuo-spatial working memory is functionally analogous to verbal working memory. Irrelevant background speech impairs verbal short-term memory. We investigated whether irrelevant visual information has an analogous effect on visual short-term memory, using a dynamic visual noise (DVN) technique known to disrupt visual imagery (Quinn & McConnell, 1996b). Experiment I replicated the effect of DVN on pegword imagery. Experiments 2 and 3 showed no effect of DVN on recall of static matrix patterns, despite a significant effect of a concurrent spatial tapping task. Experiment 4 showed no effect of DVN on encoding or maintenance of arrays of matrix patterns, despite testing memory by a recognition procedure to encourage visual rather than spatial processing. Serial position curves showed a one-item recency effect typical of visual short-term memory. Experiment 5 showed no effect of DVN on short-term recognition of Chinese characters, despite effects of visual similarity and a concurrent colour memory task that confirmed visual processing of the characters. We conclude that irrelevant visual noise does not impair visual short-term memory. Visual working memory may not be functionally analogous to verbal working memory, and different cognitive processes may underlie visual short-term memory and visual imagery.

  16. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    PubMed

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  17. Influence of wearing latex gloves on electric pulp tester readings in children.

    PubMed

    Holan, G

    1993-12-01

    Electric pulp testers operated by completing an electric circuit. Latex examination gloves have been claimed to interrupt this circuit and lead to false-negative results. This study was conducted to evaluate the influence of wearing latex gloves on electric pulp tester (EPT) readings. The pulps of 80 maxillary permanent incisors of 22 children 10-13 1/2 years old were tested using the Pelton & Crane 'Vitapulp' instrument. Each tooth was tested twice: with gloves and with bare hands. Teeth failing to respond to the EPT without gloves were excluded from the study. All EPT readings ranged between 1 and 9.5. Five teeth gave the same responses with gloved and ungloved hands. Only five teeth did not respond when gloves were worn, and all of these gave readings near the top of the EPT scale when tested without gloves. The other 70 teeth presented significantly higher readings with gloves than without gloves. It is concluded that removal of examination gloves during the operation of the EPT is necessary only if no response is obtained.

  18. Change detection technique for muscle tone during static stretching by continuous muscle viscoelasticity monitoring using wearable indentation tester.

    PubMed

    Okamura, Naomi; Kobayashi, Yo; Sugano, Shigeki; Fujie, Masakatsu G

    2017-07-01

    Static stretching is widely performed to decrease muscle tone as a part of rehabilitation protocols. Finding out the optimal duration of static stretching is important to minimize the time required for rehabilitation therapy and it would be helpful for maintaining the patient's motivation towards daily rehabilitation tasks. Several studies have been conducted for the evaluation of static stretching; however, the recommended duration of static stretching varies widely between 15-30 s in general, because the traditional methods for the assessment of muscle tone do not monitor the continuous change in the target muscle's state. We have developed a method to monitor the viscoelasticity of one muscle continuously during static stretching, using a wearable indentation tester. In this study, we investigated a suitable signal processing method to detect the time required to change the muscle tone, utilizing the data collected using a wearable indentation tester. By calculating a viscoelastic index with a certain time window, we confirmed that the stretching duration required to bring about a decrease in muscle tone could be obtained with an accuracy in the order of 1 s.

  19. Sensor set-up for wireless measurement of automotive rim and wheel parameters in laboratory conditions

    NASA Astrophysics Data System (ADS)

    Borecki, M.; Prus, P.; Korwin-Pawlowski, M. L.; Rychlik, A.; Kozubel, W.

    2017-08-01

    Modern rims and wheels are tested at the design and production stages. Tests can be performed in laboratory conditions and on the ride. In the laboratory, complex and costly equipment is used, as for example wheel balancers and impact testers. Modern wheel balancers are equipped with electronic and electro-mechanical units that enable touch-less measurement of dimensions, including precision measurement of radial and lateral wheel run-out, automatic positioning and application of the counterweights, and vehicle wheel set monitoring - tread wear, drift angles and run-out unbalance. Those tests are performed by on-wheel axis measurements with laser distance meters. The impact tester enables dropping of weights from a defined height onto a wheel. Test criteria are the loss of pressure of the tire and generation of cracks in the wheel without direct impact of the falling weights. In the present paper, a set up composed of three accelerometers, a temperature sensor and a pressure sensor is examined as the base of a wheel tester. The sensor set-up configuration, on-line diagnostic and signal transmission are discussed.

  20. Risk of HIV infection among male sex workers in Spain

    PubMed Central

    Belza, M; t for

    2005-01-01

    Objective: To assess HIV prevalence and predictive factors for HIV among male sex workers in Spain. Methods: In this study we analysed all male sex workers who visited HIV testing clinics in 19 Spanish cities between 2000 and 2002. The information was obtained during examination by means of a brief questionnaire. For repeating testers, only the last confirmed result was taken into account. Results: 418 male sex workers were included in the analysis; 58% visited these clinics for the first time and 42% were repeating testers. 67% were of foreign origin, mostly from Latin America (91%). 96% had had sex with men, 18% were transvestites or transsexuals, and 3.3% had used injected drugs. HIV prevalence was 12.2% (95% CI, 9.3 to 15.8%), and rose to 16.9% among first time testers. No differences in HIV prevalence were found between injecting drug users, transvestites/transsexuals, and men from foreign countries. Conclusion: Because of the high risk of HIV infection, male sex workers should be the target of specific preventive activities. Preventive and healthcare strategies that are culturally adapted to migrants are required. PMID:15681730

  1. A Novel EphA4-Based Small Molecule-Based Therapeutic Strategy for Prevention and Treatment of Post-Traumatic Osteoarthritis

    DTIC Science & Technology

    2015-09-01

    first three months of the project, we successfully obtained approval for our Animal Component of Research Project (ACORP) from our local IACUC and...total number of animals . The approved ACORP and the amendment were submitted to ACURO for approval and final approval from the ACURO was secured on...the tibial plateau. The injury was produced using an “Instron” servohydraulic tester with the animal under inhalation anesthesia (3% isoflurane, 0.5

  2. The efficacy of infiltration anaesthesia for adult mandibular incisors: a randomised double-blind cross-over trial comparing articaine and lidocaine buccal and buccal plus lingual infiltrations.

    PubMed

    Jaber, A; Whitworth, J M; Corbett, I P; Al-Baqshi, B; Kanaa, M D; Meechan, J G

    2010-11-01

    To compare the efficacy of 2% lidocaine and 4% articaine both with 1:100,000 adrenaline in anaesthetising the pulps of mandibular incisors. Thirty-one healthy adult volunteers received the following local anaesthetic regimens adjacent to a mandibular central incisor: 1) buccal infiltration of 1.8 mL lidocaine plus dummy lingual injection (LB), 2) buccal plus lingual infiltrations of 0.9 mL lidocaine (LBL), 3) buccal infiltration of 1.8 mL articaine plus dummy lingual injection (AB), 4) buccal plus lingual infiltrations of 0.9 mL articaine (ABL). Pulp sensitivities of the central incisor and contralateral lateral incisor were assessed electronically. Anaesthetic efficacy was determined by two methods: 1) Recording the number of episodes with no responses to maximal electronic pulp tester stimulation during the course of the study period, 2) recording the number of volunteers with no response to maximal pulp tester stimulation within 15 min and maintained for 45 min (defined as sustained anaesthesia). Data were analysed by McNemar, chi-square, Mann-Whitney and paired t-tests. For both test teeth, the number of episodes of no sensation on maximal stimulation was significantly greater after articaine than lidocaine for both techniques. The split buccal plus lingual dose was more effective than the buccal injection alone for both solutions (p <0.001). 4% articaine was more effective than 2% lidocaine when comparing sustained anaesthesia in both teeth for each technique (p <0.001), however, there was no difference in sustained anaesthesia between techniques for either tooth or solution. 4% articaine was more effective than 2% lidocaine (both with 1:100,000 adrenaline) in anaesthetising the pulps of lower incisor teeth after buccal or buccal plus lingual infiltrations.

  3. Characterization and mechanical properties investigation of TiN-Ag films onto Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Du, Dongxing; Liu, Daoxin; Zhang, Xiaohua; Tang, Jingang; Xiang, Dinggen

    2016-03-01

    To investigate their effect on fretting fatigue (FF) resistance of a Ti-6Al-4V alloy, hard solid lubricating composite films of TiN with varying silver contents (TiN-Ag) were deposited on a Ti-6Al-4V alloy using ion-assisted magnetron sputtering. The surface morphology and structure were analyzed by atomic force microscopy, X-ray diffractometry, X-ray photoelectron spectroscopy, and transmission electron microscopy. The hardness, bonding strength, and toughness of films were tested using a micro-hardness tester, scratch tester, and a repeated press-press test system that was manufactured in-house, respectively. The FF resistance of TiN-Ag composite films was studied using self-developed devices. The results show that the FF resistance of a titanium alloy can be improved by TiN-Ag composite films, which were fabricated using hard TiN coating doped with soft Ag. The FF life of Ag0.5, Ag2, Ag5, Ag10 and Ag20 composite films is 2.41, 3.18, 3.20, 2.94 and 2.87 times as great as that of the titanium alloy, respectively. This is because the composite films have the better toughness, friction lubrication, and high bonding strength. When the atomic fraction of Ag changes from 2% to 5%, the FF resistance of the composite films shows the best performance. This is attributed to the surface integrity of the composite film is sufficiently fine to prevent the initiation and early propagation of FF cracks.

  4. The evaluation of relationship between vitamin D and muscle power by micro manual muscle tester in end-stage renal disease patients.

    PubMed

    Zahed, Nargesosadat; Chehrazi, Saghar; Falaknasi, Kianosh

    2014-09-01

    Muscle force of lower limb is a major factor for sustaining physical activity. Decreased muscle force can limit physical activity, which can increase mortality and morbidity in end-stage renal disease (ESRD) patients. Muscle force depends on several factors. One of the most important factors is 25-hydroxy vitamin D (25-OHD) that affects muscle function in both uremic and non-uremic patients. The aim of this study was to investigate the association between serum level of 25-OHD and muscle force of lower extremities in hemodialysis patients estimated by a Micro Manual Muscle Tester, a digital instrument that measures muscle force in kilograms This cross-sectional study was performed on 135 adult patients, 69 male (51%) and 66 female (69%) (mean: 1.4, standard deviation: 0.5), undergoing hemodialysis. Standard biochemistry parameters were measured before hemodialysis, including 25-OHD, calcium, albumin, para-hyroid hormone and C-reactive protein (CRP). Based on the result of serum level of 25-OHD, patients were classified into the following three groups: 85 patients (63%) were 25-OHD deficient (25-OHD <30), 43 patients (32%) had a normal level of 25-OHD (30-70) and seven patients (5%) had a toxic level of 25-OHD (>70) (mean: 1.42, standard deviation: 0.59). Also, based on the result of muscle force, patients were classified into the following three groups: 84/133 patients (62%) had weak muscle force (<5 kg), 46/133 patients (34%) had normal muscle force (5-10 kg) and three patients (21%) had strong muscle force (>10 kg) (mean: 1.39, standard deviation: 0.53). There was a significant relation between 25-OHD level and muscle force (P = 0.02), between age and muscle force (P = 0.002) and between gender and muscle force (P <0.001). In our opinion, 25-OHD can be a useful drug in ESRD patients to improve muscle force and physical activity.

  5. Lighting Up Science for the Visually Impaired.

    ERIC Educational Resources Information Center

    Billings, Gilbert W.; And Others

    1980-01-01

    Described are activities designed specifically for visually impaired students, demonstrating (1) meiosis, (2) mass, (3) enzyme-substrate reactions, (4) function and relationships of flowering parts. Employed are tactile and auditory learning aids, such as the tape recorder, electric eye, Braille typewriter, textured fabrics, and three-dimensional…

  6. Effects of Colored Filters on Visual Function

    DTIC Science & Technology

    2008-05-01

    normal vision, yellow filters have been reported to reduce glare and improve overall visual performance.4-9 The claims of improved vision in dyslexia ...use of tinted lenses and colored overlays for the treatment of dyslexia and other related reading and learning disorders. American Optometric

  7. Vestibular-visual interactions in flight simulators

    NASA Technical Reports Server (NTRS)

    Clark, B.

    1977-01-01

    The following research work is reported: (1) vestibular-visual interactions; (2) flight management and crew system interactions; (3) peripheral cue utilization in simulation technology; (4) control of signs and symptoms of motion sickness; (5) auditory cue utilization in flight simulators, and (6) vestibular function: Animal experiments.

  8. Environmental surfaces and the compression of perceived visual space

    PubMed Central

    Bian, Zheng; Andersen, George J.

    2011-01-01

    The present study examined whether the compression of perceived visual space varies according to the type of environmental surface being viewed. To examine this issue, observers made exocentric distance judgments when viewing simulated 3D scenes. In 4 experiments, observers viewed ground and ceiling surfaces and performed either an L-shaped matching task (Experiments 1, 3, and 4) or a bisection task (Experiment 2). Overall, we found considerable compression of perceived exocentric distance on both ground and ceiling surfaces. However, the perceived exocentric distance was less compressed on a ground surface than on a ceiling surface. In addition, this ground surface advantage did not vary systematically as a function of the distance in the scene. These results suggest that the perceived visual space when viewing a ground surface is less compressed than the perceived visual space when viewing a ceiling surface and that the perceived layout of a surface varies as a function of the type of the surface. PMID:21669858

  9. Degraded attentional modulation of cortical neural populations in strabismic amblyopia

    PubMed Central

    Hou, Chuan; Kim, Yee-Joon; Lai, Xin Jie; Verghese, Preeti

    2016-01-01

    Behavioral studies have reported reduced spatial attention in amblyopia, a developmental disorder of spatial vision. However, the neural populations in the visual cortex linked with these behavioral spatial attention deficits have not been identified. Here, we use functional MRI–informed electroencephalography source imaging to measure the effect of attention on neural population activity in the visual cortex of human adult strabismic amblyopes who were stereoblind. We show that compared with controls, the modulatory effects of selective visual attention on the input from the amblyopic eye are substantially reduced in the primary visual cortex (V1) as well as in extrastriate visual areas hV4 and hMT+. Degraded attentional modulation is also found in the normal-acuity fellow eye in areas hV4 and hMT+ but not in V1. These results provide electrophysiological evidence that abnormal binocular input during a developmental critical period may impact cortical connections between the visual cortex and higher level cortices beyond the known amblyopic losses in V1 and V2, suggesting that a deficit of attentional modulation in the visual cortex is an important component of the functional impairment in amblyopia. Furthermore, we find that degraded attentional modulation in V1 is correlated with the magnitude of interocular suppression and the depth of amblyopia. These results support the view that the visual suppression often seen in strabismic amblyopia might be a form of attentional neglect of the visual input to the amblyopic eye. PMID:26885628

  10. Degraded attentional modulation of cortical neural populations in strabismic amblyopia.

    PubMed

    Hou, Chuan; Kim, Yee-Joon; Lai, Xin Jie; Verghese, Preeti

    2016-01-01

    Behavioral studies have reported reduced spatial attention in amblyopia, a developmental disorder of spatial vision. However, the neural populations in the visual cortex linked with these behavioral spatial attention deficits have not been identified. Here, we use functional MRI-informed electroencephalography source imaging to measure the effect of attention on neural population activity in the visual cortex of human adult strabismic amblyopes who were stereoblind. We show that compared with controls, the modulatory effects of selective visual attention on the input from the amblyopic eye are substantially reduced in the primary visual cortex (V1) as well as in extrastriate visual areas hV4 and hMT+. Degraded attentional modulation is also found in the normal-acuity fellow eye in areas hV4 and hMT+ but not in V1. These results provide electrophysiological evidence that abnormal binocular input during a developmental critical period may impact cortical connections between the visual cortex and higher level cortices beyond the known amblyopic losses in V1 and V2, suggesting that a deficit of attentional modulation in the visual cortex is an important component of the functional impairment in amblyopia. Furthermore, we find that degraded attentional modulation in V1 is correlated with the magnitude of interocular suppression and the depth of amblyopia. These results support the view that the visual suppression often seen in strabismic amblyopia might be a form of attentional neglect of the visual input to the amblyopic eye.

  11. Dielectric and conductivity studies of Co-Cu mixed ferrite

    NASA Astrophysics Data System (ADS)

    Parveez, Asiya; Shekhawat, M. S.; Nayeem, Firdous; Mohd. Shariff, S.; Sinha, R. R.; Khader, S. Abdul

    2018-05-01

    Nanoparticles of Co-Cu mixed ferrite having the basic composition Co1-xCuxFe2O4(x=0, 0.2, 0.4, 0.6, 0.8 and 1.0) were synthesized using nitrate-citrate combustion method. Structural, dielectric and a.c conductivity of nanopowders, which are sintered at 900°C were studied. Powder X-ray diffraction studies confirmed phase and their nanocrystalline nature. The peaks observed in the XRD spectrum indicated single phase spinel cubic structure for the synthesized samples. Surface morphology of the samples has been investigated using High ResolutionScanning Electron Microscope. The dielectric constant (ɛ') and dielectric loss factor (ɛ″) of nanocrystalline Co-Cu mixed ferrites were investigated as a function of frequency and Cu+2 concentration at room temperature over the frequency range 100 Hz to 1 MHz using Hioki make LCR Hi-Tester 3250. Synthesized mixed ferrites exhibited usual dielectric dispersion, dependence of ɛ' and ɛ″ with the frequency of the alternating applied electric field is in accordance with the Maxwell-Wagner type interfacial polarization. The electrical conductivity (σac) deduced from the measured dielectric data has been thoroughly analyzed and found that the conduction mechanism in Co1-xCuxFe2O4 mixed nanoferrites are in conformity with the electron hopping model.

  12. Prevalence of Color Vision Deficiency and its Correlation with Amblyopia and Refractive Errors among Primary School Children.

    PubMed

    Rajavi, Zhale; Sabbaghi, Hamideh; Baghini, Ahmad Shojaei; Yaseri, Mehdi; Sheibani, Koroush; Norouzi, Ghazal

    2015-01-01

    To determine the prevalence of color vision deficiency (CVD) and its correlation with amblyopia and refractive errors among primary school children. In this population-based cross-sectional study, 2160 children were selected from 36 primary schools; 60 students were from each school (10 students in each grade), with equal sex distribution. A complete eye examination including refraction using a photorefractometer, determination of visual acuity (VA) and color vision using a Yang vision tester, and evaluation of ocular media opacity using a direct ophthalmoscope was performed. Children who could not answer at least 4 plates of the Ishihara color test were considered as color vision deficient subjects. Amblyopia was determined if pinhole VA was worse than 0.3 LogMAR (equal to 20/40). The prevalence of CVD was 2.2% (95% CI: 1.5% to 3%) which was higher in male subjects (37 [3.5%] boys vs. 11 [1.0%] girls, P < 0.001). Mean VA was lower among students with CVD as compared to normal color vision children (P = 0.035) and amblyopia was observed in 8.3% (95% CI: 0.2% to 16.4%) of patients with CVD versus 2.1% (95% CI: 1.5% to 2.08%) of children with normal color vision perception (P = 0.005). A statistically significant correlation between lower VA and CVD was observed (P = 0.023). Although CVD was correlated with lower VA and amblyopia, there was no relationship between CVD and the type of amblyopia, refractive error, anisometropia or strabismus.

  13. Chemical labelling for visualizing native AMPA receptors in live neurons

    NASA Astrophysics Data System (ADS)

    Wakayama, Sho; Kiyonaka, Shigeki; Arai, Itaru; Kakegawa, Wataru; Matsuda, Shinji; Ibata, Keiji; Nemoto, Yuri L.; Kusumi, Akihiro; Yuzaki, Michisuke; Hamachi, Itaru

    2017-04-01

    The location and number of neurotransmitter receptors are dynamically regulated at postsynaptic sites. However, currently available methods for visualizing receptor trafficking require the introduction of genetically engineered receptors into neurons, which can disrupt the normal functioning and processing of the original receptor. Here we report a powerful method for visualizing native α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA)-type glutamate receptors (AMPARs) which are essential for cognitive functions without any genetic manipulation. This is based on a covalent chemical labelling strategy driven by selective ligand-protein recognition to tether small fluorophores to AMPARs using chemical AMPAR modification (CAM) reagents. The high penetrability of CAM reagents enables visualization of native AMPARs deep in brain tissues without affecting receptor function. Moreover, CAM reagents are used to characterize the diffusion dynamics of endogenous AMPARs in both cultured neurons and hippocampal slices. This method will help clarify the involvement of AMPAR trafficking in various neuropsychiatric and neurodevelopmental disorders.

  14. Disease Course of Patients with Unilateral Pigmentary Retinopathy

    PubMed Central

    Potsidis, Emorfily; Berson, Eliot L.

    2011-01-01

    Purpose. To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Methods. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Results. Mean annual rates of change for the affected eyes were −4.9% for visual field area, −4.7% for ERG amplitude to 0.5-Hz flashes, and −4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). Conclusions. The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity. PMID:21989720

  15. Disease course of patients with unilateral pigmentary retinopathy.

    PubMed

    Potsidis, Emorfily; Berson, Eliot L; Sandberg, Michael A

    2011-11-29

    To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Mean annual rates of change for the affected eyes were -4.9% for visual field area, -4.7% for ERG amplitude to 0.5-Hz flashes, and -4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥ 40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P < 0.0001 for all three measures). The visual acuity of affected eyes was more likely to decrease in patients presenting at >35 years of age than in patients presenting at a younger age (P = 0.0004). The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity.

  16. Program for the improvement of downhole drilling motor bearings and seals. Phase IV. Semi-annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tibbitts, G.A.; DeLafosse, P.H.; Black, A.

    1980-07-01

    Four main areas of development for the project are covered: design and fabrication of a dynamometer and a mud cooling system for the Bearing-Seal Package Test Facility; modification of the Bearing-Seal Package Test Facility based on test results; testing of new lubricant samples from Pacer Lubricants, Inc., in the Terra Tek High Temperature Lubricant Tester; and testing of new seal types in the Terra Tek Sea Tester. The Maurer Engineering Report, Semi-Annual Progress Report on Improvement of Downhole Motor Bearings and Seals by Jeff L. Barnwell, has been included as Appendix B.

  17. Comparison of strain rates of dart impacted plaques and pendulum impacted bumpers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scammell, K.L.

    1987-01-01

    The difference in strain rates prevailing during pendulum impact of bumpers versus high speed dart impact of plaques was investigated. Uni-axial strain gages were applied to the tension side of the plaques and bumpers directly opposite the point of impact. The plaques were impacted with an instrumented high rate dart impact tester and the bumpers impacted with a full scale bumper pendulum impact tester. Theoretical calculations and actual strain rate data support the conclusion that the strain rate of a plaque during dart impact significantly exceeds that of bumper strain rate during pendulum impact.

  18. Functional vision loss: a diagnosis of exclusion.

    PubMed

    Villegas, Rex B; Ilsen, Pauline F

    2007-10-01

    Most cases of visual acuity or visual field loss can be attributed to ocular pathology or ocular manifestations of systemic pathology. They can also occasionally be attributed to nonpathologic processes or malingering. Functional vision loss is any decrease in vision the origin of which cannot be attributed to a pathologic or structural abnormality. Two cases of functional vision loss are described. In the first, a 58-year-old man presented for a baseline eye examination for enrollment in a vision rehabilitation program. He reported bilateral blindness since a motor vehicle accident with head trauma 4 years prior. Entering visual acuity was "no light perception" in each eye. Ocular health examination was normal and the patient made frequent eye contact with the examiners. He was referred for neuroimaging and electrophysiologic testing. The second case was a 49-year-old man who presented with a long history of intermittent monocular diplopia. His medical history was significant for psycho-medical evaluations and a diagnosis of factitious disorder. Entering uncorrected visual acuities were 20/20 in each eye, but visual field testing found constriction. No abnormalities were found that could account for the monocular diplopia or visual field deficit. A diagnosis of functional vision loss secondary to factitious disorder was made. Functional vision loss is a diagnosis of exclusion. In the event of reduced vision in the context of a normal ocular health examination, all other pathology must be ruled out before making the diagnosis of functional vision loss. Evaluation must include auxiliary ophthalmologic testing, neuroimaging of the visual pathway, review of the medical history and lifestyle, and psychiatric evaluation. Comanagement with a psychiatrist is essential for patients with functional vision loss.

  19. Distribution of neurons in functional areas of the mouse cerebral cortex reveals quantitatively different cortical zones

    PubMed Central

    Herculano-Houzel, Suzana; Watson, Charles; Paxinos, George

    2013-01-01

    How are neurons distributed along the cortical surface and across functional areas? Here we use the isotropic fractionator (Herculano-Houzel and Lent, 2005) to analyze the distribution of neurons across the entire isocortex of the mouse, divided into 18 functional areas defined anatomically. We find that the number of neurons underneath a surface area (the N/A ratio) varies 4.5-fold across functional areas and neuronal density varies 3.2-fold. The face area of S1 contains the most neurons, followed by motor cortex and the primary visual cortex. Remarkably, while the distribution of neurons across functional areas does not accompany the distribution of surface area, it mirrors closely the distribution of cortical volumes—with the exception of the visual areas, which hold more neurons than expected for their volume. Across the non-visual cortex, the volume of individual functional areas is a shared linear function of their number of neurons, while in the visual areas, neuronal densities are much higher than in all other areas. In contrast, the 18 functional areas cluster into three different zones according to the relationship between the N/A ratio and cortical thickness and neuronal density: these three clusters can be called visual, sensory, and, possibly, associative. These findings are remarkably similar to those in the human cerebral cortex (Ribeiro et al., 2013) and suggest that, like the human cerebral cortex, the mouse cerebral cortex comprises two zones that differ in how neurons form the cortical volume, and three zones that differ in how neurons are distributed underneath the cortical surface, possibly in relation to local differences in connectivity through the white matter. Our results suggest that beyond the developmental divide into visual and non-visual cortex, functional areas initially share a common distribution of neurons along the parenchyma that become delimited into functional areas according to the pattern of connectivity established later. PMID:24155697

  20. Intensive video gaming improves encoding speed to visual short-term memory in young male adults.

    PubMed

    Wilms, Inge L; Petersen, Anders; Vangkilde, Signe

    2013-01-01

    The purpose of this study was to measure the effect of action video gaming on central elements of visual attention using Bundesen's (1990) Theory of Visual Attention. To examine the cognitive impact of action video gaming, we tested basic functions of visual attention in 42 young male adults. Participants were divided into three groups depending on the amount of time spent playing action video games: non-players (<2h/month, N=12), casual players (4-8h/month, N=10), and experienced players (>15h/month, N=20). All participants were tested in three tasks which tap central functions of visual attention and short-term memory: a test based on the Theory of Visual Attention (TVA), an enumeration test and finally the Attentional Network Test (ANT). The results show that action video gaming does not seem to impact the capacity of visual short-term memory. However, playing action video games does seem to improve the encoding speed of visual information into visual short-term memory and the improvement does seem to depend on the time devoted to gaming. This suggests that intense action video gaming improves basic attentional functioning and that this improvement generalizes into other activities. The implications of these findings for cognitive rehabilitation training are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Visual functions in amblyopia as determinants of response to treatment.

    PubMed

    Singh, Vinita; Agrawal, Siddharth

    2013-01-01

    To describe the visual functions in amblyopia as determinants of response to treatment. Sixty-nine patients with unilateral and bilateral amblyopia (114 amblyopic eyes) 3 to 15 years old (mean age: 8.80 ± 2.9 years), 40 males (58%) and 29 females (42%), were included in this study. All patients were treated by conventional occlusion 6 hours per day for mild to moderate amblyopia (visual acuity 0.70 or better) and full-time for 4 weeks followed by 6 hours per day for severe amblyopia (visual acuity 0.8 or worse). During occlusion, near activities requiring hand-eye coordination were advised. The follow-up examination was done at 3 and 6 months. Improvement in visual acuity was evaluated on the logMAR chart and correlated with the visual functions. Statistical analysis was done using Wilcoxon rank sum test (Mann-Whitney U test) and Kruskal-Wallis analysis. There was a statistically significant association of poor contrast sensitivity with the grade of amblyopia (P < .001). The grade of amblyopia (P < .01), accommodation (P < .01), stereopsis (P = .01), and mesopic visual acuity (P < .03) were found to have a correlation with response to amblyopia therapy. The grade of amblyopia (initial visual acuity) and accommodation are strong determinants of response to amblyopia therapy, whereas stereopsis and mesopic visual acuity have some value as determinants. Copyright 2013, SLACK Incorporated.

  2. Quality-by-design (QbD): effects of testing parameters and formulation variables on the segregation tendency of pharmaceutical powder measured by the ASTM D 6940-04 segregation tester.

    PubMed

    Xie, Lin; Wu, Huiquan; Shen, Meiyu; Augsburger, Larry L; Lyon, Robbe C; Khan, Mansoor A; Hussain, Ajaz S; Hoag, Stephen W

    2008-10-01

    The objective of this study was to examine the effects of testing parameters and formulation variables on the segregation tendency of pharmaceutical powders measured by the ASTM D 6940-04 segregation tester using design of experiments (DOE) approaches. The test blends consisted of 4% aspirin (ASP) and 96% microcrystalline cellulose (MCC) with and without magnesium stearate (MgS). The segregation tendency of a blend was determined by measuring the last/first (L/F) ratio, the ratio of aspirin concentrations between the first and last samples discharged from the tester. A 2(2) factorial design was used to determine the effects of measurement parameters [amount of material loaded (W), number of segregation cycles] with number of replicates 6. ANOVA showed that W was a critical parameter for segregation testing. The L/F value deviated further from 1 (greater segregation tendency) with increasing W. A 2(3) full factorial design was used to assess the effects of formulation variables: grade of ASP (unmilled, milled), grade of MCC, and amount of lubricant, MgS. MLR and ANOVA showed that the grade of ASP was the main effect contributing to segregation tendency. Principal Component Regression Analysis established a correlation between L/F and the physical properties of the blend related to ASP and MCC, the ASP/MCC particle size ratio (PSR) and powder cohesion. The physical properties of the blend related to density and flow were not influenced by the grade of ASP and were not related to the segregation tendency of the blend. The direct relationship between L/F and PSR was determined by univariate analysis. Segregation tendency increased as the ASP to MCC particle size increased. This study highlighted critical test parameters for segregation testing and identified critical physical properties of the blends that influence segregation tendency. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  3. Reliability and diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression: a pilot study.

    PubMed

    Trainor, Kate; Pinnington, Mark A

    2011-03-01

    It has been proposed that neurodynamic examination can assist differential diagnosis of upper/mid lumbar nerve root compression; however, the diagnostic validity of many of these tests has yet to be established. This pilot study aimed to establish the diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression in subjects with suspected lumbosacral radicular pain. Two independent examiners performed the slump knee bend test on subjects with radicular leg pain. Inter-tester reliability was calculated using the kappa coefficient. Slump knee bend test results were compared with magnetic resonance imaging findings, and diagnostic accuracy measures were calculated including sensitivity, specificity, predictive values and likelihood ratios. Orthopaedic spinal clinic, secondary care. Sixteen patients with radicular leg pain. All four subjects with mid lumbar nerve root compression on magnetic resonance imaging were correctly identified with the slump knee bend test; however, it was falsely positive in two individuals without the condition. Inter-tester reliability for the slump knee bend test using the kappa coefficient was 0.71 (95% confidence interval 0.33 to 1.0). Diagnostic validity calculations for the slump knee bend test (95% confidence intervals) were: sensitivity, 100% (40 to 100%); specificity, 83% (52 to 98%); positive predictive value, 67% (22 to 96%); negative predictive value, 100% (69 to 100%); positive likelihood ratio, 6.0 (1.58 to 19.4); and negative likelihood ratio, 0 (0 to 0.6). Results indicate good inter-tester reliability and suggest that the slump knee bend test has potential to be a useful clinical test for identifying patients with mid lumbar nerve root compression. Further investigation is needed on larger numbers of patients to confirm these findings. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  4. Distinct Feedforward and Feedback Effects of Microstimulation in Visual Cortex Reveal Neural Mechanisms of Texture Segregation.

    PubMed

    Klink, P Christiaan; Dagnino, Bruno; Gariel-Mathis, Marie-Alice; Roelfsema, Pieter R

    2017-07-05

    The visual cortex is hierarchically organized, with low-level areas coding for simple features and higher areas for complex ones. Feedforward and feedback connections propagate information between areas in opposite directions, but their functional roles are only partially understood. We used electrical microstimulation to perturb the propagation of neuronal activity between areas V1 and V4 in monkeys performing a texture-segregation task. In both areas, microstimulation locally caused a brief phase of excitation, followed by inhibition. Both these effects propagated faithfully in the feedforward direction from V1 to V4. Stimulation of V4, however, caused little V1 excitation, but it did yield a delayed suppression during the late phase of visually driven activity. This suppression was pronounced for the V1 figure representation and weaker for background representations. Our results reveal functional differences between feedforward and feedback processing in texture segregation and suggest a specific modulating role for feedback connections in perceptual organization. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Is visual assessment of thyroid attenuation on unenhanced CT of the chest useful for detecting hypothyroidism?

    PubMed

    Maldjian, P D; Chen, T

    2016-11-01

    To determine if visual assessment of the attenuation of morphologically normal appearing thyroid glands on unenhanced computed tomography (CT) of the chest is useful for identifying patients with decreased thyroid function. This was a retrospective study of 765 patients who underwent both unenhanced CT of the chest and thyroid function tests performed within 1 year of the CT examination. Attenuation of the thyroid gland was visually assessed in each patient relative to the attenuation of the surrounding muscles to categorise the gland as "low attenuation" (attenuation similar to surrounding muscles) or "high attenuation" (attenuation greater than surrounding muscles). Thyroid attenuation was quantitatively measured in each case to determine the validity of the visual assessment. Results of thyroid function tests were used to classify thyroid function as hypothyroid, euthyroid, or hyperthyroid. Data were analysed to determine the relationship between visual assessment of thyroid attenuation and status of thyroid function. Thyroid glands of low attenuation were present in 4.2% (32/765) of the patients. Nearly half (47%) of the patients with low-attenuation thyroids had hypofunctioning thyroid glands. Compared to patients with high-attenuation thyroids, patients with low-attenuation thyroids were significantly more likely to have decreased thyroid function (clinical and subclinical hypothyroidism) and significantly less likely to be euthyroid (p<0.0001). Quantitative measurement of thyroid attenuation confirmed the validity of the visual assessment. Low attenuation of an otherwise normal-appearing thyroid gland on unenhanced CT of the chest is strongly associated with decreased thyroid function. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Sliding wear and friction behaviour of zircaloy-4 in water

    NASA Astrophysics Data System (ADS)

    Sharma, Garima; Limaye, P. K.; Jadhav, D. T.

    2009-11-01

    In water cooled nuclear reactors, the sliding of fuel bundles in fuel channel handling system can lead to severe wear and it is an important topic to study. In the present study, sliding wear behaviour of zircaloy-4 was investigated in water (pH ˜ 10.5) using ball-on-plate sliding wear tester. Sliding wear resistance zircaloy-4 against SS 316 was examined at room temperature. Sliding wear tests were carried out at different load and sliding frequencies. The coefficient of friction of zircaloy-4 was also measured during each tests and it was found to decrease slightly with the increase in applied load. The micro-mechanisms responsible for wear in zircaloy-4 were identified to be microcutting, micropitting and microcracking of deformed subsurface zones in water.

  7. The efficacy of supplemental intraosseous anesthesia after insufficient mandibular block.

    PubMed

    Prohić, Samir; Sulejmanagić, Halid; Secić, Sadeta

    2005-02-01

    It is a well-known scientific fact that only a small percentage of infiltration of inferior alveolar nerve is clinically proven to be efficient. The objective of this study was to determine the anesthetic efficacy of supplemental intraosseous injection, used after the insufficient classical mandibular block that didn't provide deep pulp anesthesia of mandibular molar planed for extraction. The experimental teeth consisted of 98 mandibular molars with clinical indication for extraction. Based on the history of disease, we indicated the extraction of the tooth. After that each tooth was tested with a electric pulp tester P1. We tested the pulp vitality and precisely determined the level of vitality. After that, each patient received classical mandibular block, and the pulp vitality was tested again. If the pulp tester indicated negative vitality for the certain mandibular molar, and the patient didn't complain about pain or discomfort during the extraction, the molar was extracted and the result was added to anesthetic success rate for the classical mandibular block. If, five minutes after receiving the mandibular block, the pulp tester indicated positive vitality (parameters of vitality) or the patient complained about pain or discomfort (parameters of pain and discomfort), we used the Stabident intraosseous anesthesia system. Three minutes after the application of supplemental intraosseous injection the molar was tested with the pulp tester again. The anesthetic solution used in both anesthetic techniques is lidocaine with 1:100.000 epinephrine. The results of this study indicate that the anesthetic efficacy of the mandibular block is 74.5%, and that supplemental intraosseous anesthesia, applied after the insufficient mandibular block, provides pulpal anesthesia in 94.9% of mandibular molars. The difference between anesthetic efficacy of the classical mandibular block and anesthetic efficacy of the supplemental intraosseous anesthesia, applied after the insufficient mandibular block, is obvious.

  8. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    PubMed

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were <1.0 mm/1.0° for comparison of all translations/rotations obtained by a single tester and <1.0 mm/2.0° for comparison obtained by 2 different testers. Assessment of reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. The reliability and validity of the Saliba Postural Classification System

    PubMed Central

    Collins, Cristiana Kahl; Johnson, Vicky Saliba; Godwin, Ellen M.; Pappas, Evangelos

    2016-01-01

    Objectives To determine the reliability and validity of the Saliba Postural Classification System (SPCS). Methods Two physical therapists classified pictures of 100 volunteer participants standing in their habitual posture for inter and intra-tester reliability. For validity, 54 participants stood on a force plate in a habitual and a corrected posture, while a vertical force was applied through the shoulders until the clinician felt a postural give. Data were extracted at the time the give was felt and at a time in the corrected posture that matched the peak vertical ground reaction force (VGRF) in the habitual posture. Results Inter-tester reliability demonstrated 75% agreement with a Kappa = 0.64 (95% CI = 0.524–0.756, SE = 0.059). Intra-tester reliability demonstrated 87% agreement with a Kappa = 0.8, (95% CI = 0.702–0.898, SE = 0.05) and 80% agreement with a Kappa = 0.706, (95% CI = 0.594–0818, SE = 0.057). The examiner applied a significantly higher (p < 0.001) peak vertical force in the corrected posture prior to a postural give when compared to the habitual posture. Within the corrected posture, the %VGRF was higher when the test was ongoing vs. when a postural give was felt (p < 0.001). The %VGRF was not different between the two postures when comparing the peaks (p = 0.214). Discussion The SPCS has substantial agreement for inter- and intra-tester reliability and is largely a valid postural classification system as determined by the larger vertical forces in the corrected postures. Further studies on the correlation between the SPCS and diagnostic classifications are indicated. PMID:27559288

  10. The reliability and validity of the Saliba Postural Classification System.

    PubMed

    Collins, Cristiana Kahl; Johnson, Vicky Saliba; Godwin, Ellen M; Pappas, Evangelos

    2016-07-01

    To determine the reliability and validity of the Saliba Postural Classification System (SPCS). Two physical therapists classified pictures of 100 volunteer participants standing in their habitual posture for inter and intra-tester reliability. For validity, 54 participants stood on a force plate in a habitual and a corrected posture, while a vertical force was applied through the shoulders until the clinician felt a postural give. Data were extracted at the time the give was felt and at a time in the corrected posture that matched the peak vertical ground reaction force (VGRF) in the habitual posture. Inter-tester reliability demonstrated 75% agreement with a Kappa = 0.64 (95% CI = 0.524-0.756, SE = 0.059). Intra-tester reliability demonstrated 87% agreement with a Kappa = 0.8, (95% CI = 0.702-0.898, SE = 0.05) and 80% agreement with a Kappa = 0.706, (95% CI = 0.594-0818, SE = 0.057). The examiner applied a significantly higher (p < 0.001) peak vertical force in the corrected posture prior to a postural give when compared to the habitual posture. Within the corrected posture, the %VGRF was higher when the test was ongoing vs. when a postural give was felt (p < 0.001). The %VGRF was not different between the two postures when comparing the peaks (p = 0.214). The SPCS has substantial agreement for inter- and intra-tester reliability and is largely a valid postural classification system as determined by the larger vertical forces in the corrected postures. Further studies on the correlation between the SPCS and diagnostic classifications are indicated.

  11. Halogenated 2,5-pyrrolidinediones: synthesis, bacterial mutagenicity in Ames tester strain TA-100 and semi-empirical molecular orbital calculations.

    PubMed

    Freeman, B A; Wilson, R E; Binder, R G; Haddon, W F

    2001-02-20

    The chloroimide 3,3-dichloro-4-(dichloromethylene)-2,5-pyrrolidinedione, a tetrachloroitaconimide, is the principal mutagen produced by chlorination of simulated poultry chiller water. It is the second most potent mutagenic disinfection by-product of chlorination ever reported. Six of seven new synthetic analogs of this compound are direct-acting mutagens in Ames tester strain TA-100. Computed energies of the lowest unoccupied molecular orbital (E(LUMO)) and of the radical anion stability (DeltaH(f)(rad)-DeltaH(f)) from MNDO-PM3 for the chloroimides show a quantitative correlation with the Ames TA-100 bacterial mutagenicity values. The molar mutagenicities of these direct acting mutagenic imides having an exocyclic double bond fit the same linear correlation (lnM(m) vs. E(LUMO); lnM(m) vs. DeltaH(f)(rad)--DeltaH(f)) as the chlorinated 2(5H)-furanones, including the potent mutagen MX, 3-chloro-4-(dichloro-methyl)-5-hydroxy-2(5H)-furanone, a by-product of water chlorination and paper bleaching with chlorine. Mutagenicity data for related haloimides having endocyclic double bonds are also given. For the same number of chlorine atoms, the imides with endocyclic double bonds have significantly higher Ames mutagenicity compared to their structural analogs with exocyclic double bonds, but do not follow the same E(LUMO) or DeltaH(f)(rad)-DeltaH(f) correlation as the exocyclic chloroimides and the chlorinated 2(5H)-furanones.

  12. Potent suppressing activity of the non-polyphenolic fraction of green tea (Camellia sinensis) against genotoxin-induced umu C gene expression in Salmonella typhimurium (TA 1535/pSK 1002)--association with pheophytins a and b.

    PubMed

    Okai, Y; Higashi-Okai, K

    1997-11-25

    Antigenotoxic and antimutagenic activities of green tea extract and tea-derived polyphenols have been studied using in vitro and in vivo experiments. However, antigenotoxic substances in the non-polyphenolic fraction of green tea have been poorly elucidated. In the present study, the effect of the non-polyphenolic fraction of green tea on genotoxin-induced umu C gene expression was analyzed using a tester bacteria, and potent antigenotoxic substances in the non-polyphenolic fraction were identified. The non-polyphenolic fraction of green tea showed strong suppressive activities against umu C gene expression in Salmonella typhimurium (TA 1535/pSK 1002) induced by 3-amino-1,4-dimethyl-5H-pyrido[4,3-b]indol (Trp-P-1) or mitomycin C (MMC) in the presence or absence of S9 metabolizing enzyme mixture. The non-polyphenolic fraction of green tea exhibited major two-color bands in a silica gel TLC and they were identified as chlorophyll-related compounds, pheophytins a and b, judged by their specific colors, Rf values in silica gel TLC and absorption spectra. These pigments showed significant suppressive activities against umu C gene expression in tester bacteria induced by Trp-P- and MMC in a dose-dependent manner. These results suggest that the non-polyphenolic fraction of green tea contains pheophytins a and b as potent antigenotoxic substances.

  13. Characterization of Intraocular Pressure Increases and Management Strategies Following Treatment With Fluocinolone Acetonide Intravitreal Implants in the FAME Trials.

    PubMed

    Parrish, Richard K; Campochiaro, Peter A; Pearson, P Andrew; Green, Ken; Traverso, Carlo E

    2016-05-01

    To compare elevated intraocular pressure (IOP) management and outcomes among patients with diabetic macular edema who received fluocinolone acetonide (FAc) implants versus sham-control treatment and explore the prior ocular steroid exposure impact on IOP outcomes. Best-corrected visual acuity (BCVA) was measured using Early Treatment Diabetic Retinopathy Study charts or electronic VA testers. Goldmann applanation tonometry was used to measure IOP. Elevated IOP was more common in FAc-versus sham control-treated patients. Medication, and less often trabeculoplasty or surgery, was used to lower IOP without affecting VA outcomes. No patient treated with 0.2 µg/day FAc who received prior ocular steroid required IOP-lowering surgery. Elevated IOP may occur following FAc implant receipt; however, in the present study, it was manageable and did not impact vision outcomes. Patients previously treated with ocular steroid did not require IOP-lowering surgery following 0.2 µg/day FAc implant administration. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:426-435.]. Copyright 2016, SLACK Incorporated.

  14. Functionalized hybrid nanofibers to mimic native ECM for tissue engineering applications

    NASA Astrophysics Data System (ADS)

    Karuppuswamy, Priyadharsini; Venugopal, Jayarama Reddy; Navaneethan, Balchandar; Laiva, Ashang Luwang; Sridhar, Sreepathy; Ramakrishna, Seeram

    2014-12-01

    Nanotechnology being one of the most promising technologies today shows an extremely huge potential in the field of tissue engineering to mimic the porous topography of natural extracellular matrix (ECM). Natural polymers are incorporated into the synthetic polymers to fabricate functionalized hybrid nanofibrous scaffolds, which improve cell and tissue compatibility. The present study identified the biopolymers - aloe vera, silk fibroin and curcumin incorporated into polycaprolactone (PCL) as suitable substrates for tissue engineering. Different combinations of PCL with natural polymers - PCL/aloe vera, PCL/silk fibroin, PCL/aloe vera/silk fibroin, PCL/aloe vera/silk fibroin/curcumin were electrospun into nanofibrous scaffolds. The fabricated two dimensional nanofibrous scaffolds showed high surface area, appropriate mechanical properties, hydrophilicity and porosity, required for the regeneration of diseased tissues. The nanofibrous scaffolds were characterized by Scanning electron microscope (SEM), porometry, Instron tensile tester, VCA optima contact angle measurement and FTIR to analyze the fiber diameter and morphology, porosity and pore size distribution, mechanical strength, wettability, chemical bonds and functional groups, respectively. The average fiber diameter of obtained fibers ranged from 250 nm to 350 nm and the tensile strength of PCL scaffolds at 4.49 MPa increased upto 8.3 MPa for PCL/silk fibroin scaffolds. Hydrophobicity of PCL decreased with the incorporation of natural polymers, especially for PCL/aloe vera scaffolds. The properties of as-spun nanofiber scaffolds showed their potential as promising scaffold materials in tissue engineering applications.

  15. Residual effects of ecstasy (3,4-methylenedioxymethamphetamine) on low level visual processes.

    PubMed

    Murray, Elizabeth; Bruno, Raimondo; Brown, John

    2012-03-01

    'Ecstasy' (3,4-methylenedioxymethamphetamine) induces impaired functioning in the serotonergic system, including the occipital lobe. This study employed the 'tilt aftereffect' paradigm to operationalise the function of orientation-selective neurons among ecstasy consumers and controls as a means of investigating the role of reduced serotonin on visual orientation processing. The magnitude of the tilt aftereffect reflects the extent of lateral inhibition between orientation-selective neurons and is elicited to both 'real' contours, processed in visual cortex area V1, and illusory contours, processed in V2. The magnitude of tilt aftereffect to both contour types was examined among 19 ecstasy users (6 ecstasy only; 13 ecstasy-plus-cannabis users) and 23 matched controls (9 cannabis-only users; 14 drug-naive). Ecstasy users had a significantly greater tilt magnitude than non-users for real contours (Hedge's g = 0.63) but not for illusory contours (g = 0.20). These findings provide support for literature suggesting that residual effects of ecstasy (and reduced serotonin) impairs lateral inhibition between orientation-selective neurons in V1, which however suggests that ecstasy may not substantially affect this process in V2. Multiple studies have now demonstrated ecstasy-related deficits on basic visual functions, including orientation and motion processing. Such low-level effects may contribute to the impact of ecstasy use on neuropsychological tests of visuospatial function. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Short-term retention of visual information: Evidence in support of feature-based attention as an underlying mechanism.

    PubMed

    Sneve, Markus H; Sreenivasan, Kartik K; Alnæs, Dag; Endestad, Tor; Magnussen, Svein

    2015-01-01

    Retention of features in visual short-term memory (VSTM) involves maintenance of sensory traces in early visual cortex. However, the mechanism through which this is accomplished is not known. Here, we formulate specific hypotheses derived from studies on feature-based attention to test the prediction that visual cortex is recruited by attentional mechanisms during VSTM of low-level features. Functional magnetic resonance imaging (fMRI) of human visual areas revealed that neural populations coding for task-irrelevant feature information are suppressed during maintenance of detailed spatial frequency memory representations. The narrow spectral extent of this suppression agrees well with known effects of feature-based attention. Additionally, analyses of effective connectivity during maintenance between retinotopic areas in visual cortex show that the observed highlighting of task-relevant parts of the feature spectrum originates in V4, a visual area strongly connected with higher-level control regions and known to convey top-down influence to earlier visual areas during attentional tasks. In line with this property of V4 during attentional operations, we demonstrate that modulations of earlier visual areas during memory maintenance have behavioral consequences, and that these modulations are a result of influences from V4. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Operator vision aids for space teleoperation assembly and servicing

    NASA Technical Reports Server (NTRS)

    Brooks, Thurston L.; Ince, Ilhan; Lee, Greg

    1992-01-01

    This paper investigates concepts for visual operator aids required for effective telerobotic control. Operator visual aids, as defined here, mean any operational enhancement that improves man-machine control through the visual system. These concepts were derived as part of a study of vision issues for space teleoperation. Extensive literature on teleoperation, robotics, and human factors was surveyed to definitively specify appropriate requirements. This paper presents these visual aids in three general categories of camera/lighting functions, display enhancements, and operator cues. In the area of camera/lighting functions concepts are discussed for: (1) automatic end effector or task tracking; (2) novel camera designs; (3) computer-generated virtual camera views; (4) computer assisted camera/lighting placement; and (5) voice control. In the technology area of display aids, concepts are presented for: (1) zone displays, such as imminent collision or indexing limits; (2) predictive displays for temporal and spatial location; (3) stimulus-response reconciliation displays; (4) graphical display of depth cues such as 2-D symbolic depth, virtual views, and perspective depth; and (5) view enhancements through image processing and symbolic representations. Finally, operator visual cues (e.g., targets) that help identify size, distance, shape, orientation and location are discussed.

  18. A microprocessor tester for the treat upgrade reactor trip system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenkszus, F.R.; Bucher, R.G.

    1985-02-01

    The upgrading of the Transient Reactor Test (TREAT) Facility at ANL-Idaho has been designed to provide additional experimental capabilities for the study of core disruptive accident (CDA) phenomena. To improve the analytical extrapolation of test results to full-size assembly bundles, the facility upgrade will increase the maximum size of the test bundle from 7 to 37 fuel pins. By creating a core convertor zone around the test location, the neutron spectrum incident on the test assembly will be hardened and the maximum energy deposited in the sample will be increased. In addition, a programmable Automated Reactor Control System (ARCS) willmore » permit high-power transients up to 11,000 MW having a controlled reactor period of from 15 to 0.1 sec. These modifications to the core neutronics will improve simulation of LMFBR accident conditions. Finally, a sophisticated, multiply-redundant safety system, the Reactor Trip System (RTS), will provide safe operation for both steady state and transient production operating modes. To insure that this complex safety system is functioning properly, a Dedicated Microprocessor Tester (DMT) has been implemented to perform a thorough checkout of the RTS prior to all TREAT operations. A quantitative reliability analysis of the RTS shows that the unreliability, that is, the probability of failure, is acceptable for a 10 hour mission time or risk interval.« less

  19. Mirror therapy combined with biofeedback functional electrical stimulation for motor recovery of upper extremities after stroke: a pilot randomized controlled trial.

    PubMed

    Kim, Jung Hee; Lee, Byoung-Hee

    2015-06-01

    The objective of this study was to evaluate the effects of mirror therapy in combination with biofeedback functional electrical stimulation (BF-FES) on motor recovery of the upper extremities after stroke. Twenty-nine patients who suffered a stroke > 6 months prior participated in this study and were randomly allocated to three groups. The BF-FES + mirror therapy and FES + mirror therapy groups practiced training for 5 × 30 min sessions over a 4-week period. The control group received a conventional physical therapy program. The following clinical tools were used to assess motor recovery of the upper extremities: electrical muscle tester, electrogoniometer, dual-inclinometer, electrodynamometer, the Box and Block Test (BBT) and Jabsen Taylor Hand Function Test (JHFT), the Functional Independence Measure, the Modified Ashworth Scale, and the Stroke Specific Quality of Life (SSQOL) assessment. The BF-FES + mirror therapy group showed significant improvement in wrist extension as revealed by the Manual Muscle Test and Range of Motion (p < 0.05). The BF-FES + mirror therapy group showed significant improvement in the BBT, JTHT, and SSQOL compared with the FES + mirror therapy group and control group (p < 0.05). We found that BF-FES + mirror therapy induced motor recovery and improved quality of life. These results suggest that mirror therapy, in combination with BF-FES, is feasible and effective for motor recovery of the upper extremities after stroke. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Instrumental resolution of the chopper spectrometer 4SEASONS evaluated by Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Kajimoto, Ryoichi; Sato, Kentaro; Inamura, Yasuhiro; Fujita, Masaki

    2018-05-01

    We performed simulations of the resolution function of the 4SEASONS spectrometer at J-PARC by using the Monte Carlo simulation package McStas. The simulations showed reasonably good agreement with analytical calculations of energy and momentum resolutions by using a simplified description. We implemented new functionalities in Utsusemi, the standard data analysis tool used in 4SEASONS, to enable visualization of the simulated resolution function and predict its shape for specific experimental configurations.

  1. The functional neuroanatomy of object agnosia: a case study.

    PubMed

    Konen, Christina S; Behrmann, Marlene; Nishimura, Mayu; Kastner, Sabine

    2011-07-14

    Cortical reorganization of visual and object representations following neural injury was examined using fMRI and behavioral investigations. We probed the visual responsivity of the ventral visual cortex of an agnosic patient who was impaired at object recognition following a lesion to the right lateral fusiform gyrus. In both hemispheres, retinotopic mapping revealed typical topographic organization and visual activation of early visual cortex. However, visual responses, object-related, and -selective responses were reduced in regions immediately surrounding the lesion in the right hemisphere, and also, surprisingly, in corresponding locations in the structurally intact left hemisphere. In contrast, hV4 of the right hemisphere showed expanded response properties. These findings indicate that the right lateral fusiform gyrus is critically involved in object recognition and that an impairment to this region has widespread consequences for remote parts of cortex. Finally, functional neural plasticity is possible even when a cortical lesion is sustained in adulthood. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Cable Tester

    NASA Technical Reports Server (NTRS)

    1989-01-01

    NASA Tech Brief's provided Sonics Associates, Inc. with a method of saving many hours of testing time and money. James B. Cawthon, Sonics Vice-President, read about a device developed at Ames Research Center. Sonics adapted the device and produced an effective tester that uses a clocked shift register to apply a voltage to a cable under test. This is the active part of the Ames development, and the passive is a small box containing light emitting diodes (LEDs). When connected to the other end of the tested cable, the LEDs light in the same sequence as the generator. This procedure allows the technician to immediately identify a miswired cable.

  3. A Method for Measuring the Hardness of the Surface Layer on Hot Forging Dies Using a Nanoindenter

    NASA Astrophysics Data System (ADS)

    Mencin, P.; van Tyne, C. J.; Levy, B. S.

    2009-11-01

    The properties and characteristics of the surface layer of forging dies are critical for understanding and controlling wear. However, the surface layer is very thin, and appropriate property measurements are difficult to obtain. The objective of the present study is to determine if nanoindenter testing provides a reliable method, which could be used to measure the surface hardness in forging die steels. To test the reliability of nanoindenter testing, nanoindenter values for two quenched and tempered steels (FX and H13) are compared to microhardness and macrohardness values. These steels were heat treated for various times to produce specimens with different values of hardness. The heat-treated specimens were tested using three different instruments—a Rockwell hardness tester for macrohardness, a Vickers hardness tester for microhardness, and a nanoindenter tester for fine scale evaluation of hardness. The results of this study indicate that nanoindenter values obtained using a Nanoindenter XP Machine with a Berkovich indenter reliably correlate with Rockwell C macrohardness values, and with Vickers HV microhardness values. Consequently, nanoindenter testing can provide reliable results for analyzing the surface layer of hot forging dies.

  4. Determination of flash point in air and pure oxygen using an equilibrium closed bomb apparatus.

    PubMed

    Kong, Dehong; am Ende, David J; Brenek, Steven J; Weston, Neil P

    2003-08-29

    The standard closed testers for flash point measurements may not be feasible for measuring flash point in special atmospheres like oxygen because the test atmosphere cannot be maintained due to leakage and the laboratory safety can be compromised. To address these limitations we developed a new "equilibrium closed bomb" (ECB). The ECB generally gives lower flash point values than standard closed cup testers as shown by the results of six flammable liquids. The present results are generally in good agreement with the values calculated from the reported lower flammability limits and the vapor pressures. Our measurements show that increased oxygen concentration had little effect on the flash points of the tested flammable liquids. While generally regarded as non-flammable because of the lack of observed flash point in standard closed cup flash point testers, dichloromethane is known to form flammable mixtures. The flash point of dichloromethane in oxygen measured in the ECB is -7.1 degrees C. The flash point of dichloromethane in air is dependent on the type and energy of the ignition source. Further research is being carried out to establish the relationship between the flash point of dichloromethane and the energy of the ignition source.

  5. Hip range of motion and provocative physical examination tests reliability and agreement in asymptomatic volunteers

    PubMed Central

    Prather, H; Harris-Hayes, M; Hunt, D; Steger-May, K; Mathew, V; Clohisy, JC

    2012-01-01

    Objective The objectives of this study are the following: 1) report passive hip ROM in asymptomatic young adults, 2) report the intra-tester and inter-tester reliability of hip ROM measurements among testers of multiple disciplines, 3) report the results of provocative hip tests and tester agreement. Design descriptive epidemiology study Setting tertiary university Participants Twenty-eight young adult volunteers without musculoskeletal symptoms, history of disorder or surgery involving the lumbar spine or lower extremities were enrolled and completed the study. Methods Asymptomatic young adult volunteers completed questionnaires and were examined by two blinded examiners during a single session. The testers were physical therapists and physicians. Hip range of motion and provocative tests were completed by both examiners on each hip. Main Outcome Measurements Inter and intra-rater reliability for ROM and agreement for provocative tests was determined. Results Twenty-eight asymptomatic adults with mean age 31 years old (range 18–51 years) and mean modified Harris Hip Score of 99.5 ± 1.5 and UCLA Activity score of 8.8 ± 1.2 completed the study. Intra-rater agreement was excellent for all hip range of motion measurements, with intraclass correlation coefficients (ICCs) ranging from 0.76 to 0.97 with similar agreement if the examiner was a physical therapist or a physician. Excellent inter-rater reliability was found for hip flexion ICC 0.87 (95% CI 0.78 to 0.92), supine internal rotation ICC 0.75 (95% CI 0.60 to 0.84) and prone internal rotation ICC 0.79 (95% CI 0.66 to 0.87). The least reliable measurements were supine hip abduction (ICC 0.34) and supine external rotation (ICC 0.18). Agreement between examiners ranged from 96–100% for provocative hip tests which included the hip impingement, resisted straight leg raise, FABER/Patrick’s and log roll tests. Conclusions Specific hip ROM measures show excellent inter-rater reliability and provocative hip tests show good agreement among multiple examiners and medical disciplines. Further studies are needed to assess the utilization of these measurements and tests as a part of a hip screening examination to assess for young adults at risk intra-articular hip disorders prior to the onset of degenerative changes. PMID:20970757

  6. Impact of Vial Capping on Residual Seal Force and Container Closure Integrity.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Ovadia, Robert; Lam, Philippe; Stauch, Oliver; Vogt, Martin; Roehl, Holger; Huwyler, Joerg; Mohl, Silke; Streubel, Alexander

    2016-01-01

    The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. Additionally, container closure integrity of these samples was measured using helium leakage (physical container closure integrity) and compared to characterization data. The different capping equipment settings lead to residual seal force values from 7 to 115 N. High residual seal force values were achieved with high capping pre-compression force and a short distance between the capping plate and plunge. The choice of container closure system influenced the obtained residual seal force values. The residual seal force tester and piezoelectric measurements showed similar trends. All vials passed physical container closure integrity testing, and no stopper rupture was seen with any of the settings applied, suggesting that container closure integrity was warranted for the studied container closure system with the chosen capping setting ranges. The vial capping process is a critical unit operation during drug product manufacturing, as it could possibly generate cosmetic defects or even affect container closure integrity. Yet there is significant variability in capping equipment and processes, and their relation to potential defects or container closure integrity has not been thoroughly studied. In this study we applied several methods-residual seal force tester, a self-developed system of a piezo force sensor measurement, and computed tomography-to characterize different container closure system combinations that had been sealed using different capping process parameter settings. The residual seal force tester can analyze a variety of different container closure systems independent of the capping equipment. An adequate and safe residual seal force range for each container closure system configuration can be established with the residual seal force tester and additional methods like computed tomography scans and leak testing. In the residual seal force range studied, the physical container closure integrity of the container closure system was warranted. © PDA, Inc. 2016.

  7. [Functional state of the visual analyzer in the conditions of the use of traditional and LED light sources].

    PubMed

    Kaptsov, V A; Sosunov, N N; Shishchenko, I I; Viktorov, V S; Tulushev, V N; Deynego, V N; Bukhareva, E A; Murashova, M A; Shishchenko, A A

    2014-01-01

    There was performed the experimental work on the study of the possibility of the application of LED lighting (LED light sources) in rail transport for traffic safety in related professions. Results of 4 series of studies involving 10 volunteers for the study and a comparative evaluation of the functional state of the visual analyzer, the general functional state and mental capacity under the performing the simulated operator activity in conditions of traditional light sources (incandescent, fluorescent lamp) and the new LED (LED lamp, LED panel) light sources have revealed changes in the negative direction. This was pronounced in a some decrease of functional stability to color discrimination between green and red cone signals, as well as an increase in response time in complex visual--motor response and significant reduction in readiness for emergency action of examinees.

  8. Functional vision in children with perinatal brain damage.

    PubMed

    Alimović, Sonja; Jurić, Nikolina; Bošnjak, Vlatka Mejaški

    2014-09-01

    Many authors have discussed the effects of visual stimulations on visual functions, but there is no research about the effects on using vision in everyday activities (i.e. functional vision). Children with perinatal brain damage can develop cerebral visual impairment with preserved visual functions (e.g. visual acuity, contrast sensitivity) but poor functional vision. Our aim was to discuss the importance of assessing and stimulating functional vision in children with perinatal brain damage. We assessed visual functions (grating visual acuity, contrast sensitivity) and functional vision (the ability of maintaining visual attention and using vision in communication) in 99 children with perinatal brain damage and visual impairment. All children were assessed before and after the visual stimulation program. Our first assessment results showed that children with perinatal brain damage had significantly more problems in functional vision than in basic visual functions. During the visual stimulation program both variables of functional vision and contrast sensitivity improved significantly, while grating acuity improved only in 2.7% of children. We also found that improvement of visual attention significantly correlated to improvement on all other functions describing vision. Therefore, functional vision assessment, especially assessment of visual attention is indispensable in early monitoring of child with perinatal brain damage.

  9. Relating Sensitivity and Criterion Effects to the Internal Mechanisms of Visual Spatial Attention

    DTIC Science & Technology

    1988-04-30

    Hughes & Zimba , 1987; Rizzolatti, Riggio, Descola & *, .. Umilta, 1987). Further, deficits for uncued locations are a function 4. of the distance...Wilson, 1986; Rizzolatti, et. al., 1987; Hughes & Zimba , 1987, argue that this effect depends upon the use of an articulated visual field). Distance...Hughes, H. & Zimba , L. (1987) Nat,ral boundaries for the spatial spread of directed visual attention. Neuropsychologia, 25, 5-18. O Jonides, J. (1976

  10. Functional interplay of top-down attention with affective codes during visual short-term memory maintenance.

    PubMed

    Kuo, Bo-Cheng; Lin, Szu-Hung; Yeh, Yei-Yu

    2018-06-01

    Visual short-term memory (VSTM) allows individuals to briefly maintain information over time for guiding behaviours. Because the contents of VSTM can be neutral or emotional, top-down influence in VSTM may vary with the affective codes of maintained representations. Here we investigated the neural mechanisms underlying the functional interplay of top-down attention with affective codes in VSTM using functional magnetic resonance imaging. Participants were instructed to remember both threatening and neutral objects in a cued VSTM task. Retrospective cues (retro-cues) were presented to direct attention to the hemifield of a threatening object (i.e., cue-to-threat) or a neutral object (i.e., cue-to-neutral) during VSTM maintenance. We showed stronger activity in the ventral occipitotemporal cortex and amygdala for attending threatening relative to neutral representations. Using multivoxel pattern analysis, we found better classification performance for cue-to-threat versus cue-to-neutral objects in early visual areas and in the amygdala. Importantly, retro-cues modulated the strength of functional connectivity between the frontoparietal and early visual areas. Activity in the frontoparietal areas became strongly correlated with the activity in V3a-V4 coding the threatening representations instructed to be relevant for the task. Together, these findings provide the first demonstration of top-down modulation of activation patterns in early visual areas and functional connectivity between the frontoparietal network and early visual areas for regulating threatening representations during VSTM maintenance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The Retinotopic Organization of Macaque Occipitotemporal Cortex Anterior to V4 and Caudoventral to the Middle Temporal (MT) Cluster

    PubMed Central

    Janssens, Thomas; Orban, Guy A.

    2014-01-01

    The retinotopic organization of macaque occipitotemporal cortex rostral to area V4 and caudorostral to the recently described middle temporal (MT) cluster of the monkey (Kolster et al., 2009) is not well established. The proposed number of areas within this region varies from one to four, underscoring the ambiguity concerning the functional organization in this region of extrastriate cortex. We used phase-encoded retinotopic functional MRI mapping methods to reveal the functional topography of this cortical domain. Polar-angle maps showed one complete hemifield representation bordering area V4 anteriorly, split into dorsal and ventral counterparts corresponding to the lower and upper visual field quadrants, respectively. The location of this hemifield representation corresponds to area V4A. More rostroventrally, we identified three other complete hemifield representations. Two of these correspond to the dorsal and the ventral posterior inferotemporal areas (PITd and PITv, respectively) as identified in the Felleman and Van Essen (1991) scheme. The third representation has been tentatively named dorsal occipitotemporal area (OTd). Areas V4A, PITd, PITv, and OTd share a central visual field representation, similar to the areas constituting the MT cluster. Furthermore, they vary widely in size and represent the complete contralateral visual field. Functionally, these four areas show little motion sensitivity, unlike those of the MT cluster, and two of them, OTd and PITd, displayed pronounced two-dimensional shape sensitivity. In general, these results suggest that retinotopically organized tissue extends farther into rostral occipitotemporal cortex of the monkey than generally assumed. PMID:25080580

  12. Latent binocular function in amblyopia.

    PubMed

    Chadnova, Eva; Reynaud, Alexandre; Clavagnier, Simon; Hess, Robert F

    2017-11-01

    Recently, psychophysical studies have shown that humans with amblyopia do have binocular function that is not normally revealed due to dominant suppressive interactions under normal viewing conditions. Here we use magnetoencephalography (MEG) combined with dichoptic visual stimulation to investigate the underlying binocular function in humans with amblyopia for stimuli that, because of their temporal properties, would be expected to bypass suppressive effects and to reveal any underlying binocular function. We recorded contrast response functions in visual cortical area V1 of amblyopes and normal observers using a steady state visually evoked responses (SSVER) protocol. We used stimuli that were frequency-tagged at 4Hz and 6Hz that allowed identification of the responses from each eye and were of a sufficiently high temporal frequency (>3Hz) to bypass suppression. To characterize binocular function, we compared dichoptic masking between the two eyes in normal and amblyopic participants as well as interocular phase differences in the two groups. We observed that the primary visual cortex responds less to the stimulation of the amblyopic eye compared to the fellow eye. The pattern of interaction in the amblyopic visual system however was not significantly different between the amblyopic and fellow eyes. However, the amblyopic suppressive interactions were lower than those observed in the binocular system of our normal observers. Furthermore, we identified an interocular processing delay of approximately 20ms in our amblyopic group. To conclude, when suppression is greatly reduced, such as the case with our stimulation above 3Hz, the amblyopic visual system exhibits a lack of binocular interactions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A pilot randomized controlled trial comparing effectiveness of prism glasses, visual search training and standard care in hemianopia.

    PubMed

    Rowe, F J; Conroy, E J; Bedson, E; Cwiklinski, E; Drummond, A; García-Fiñana, M; Howard, C; Pollock, A; Shipman, T; Dodridge, C; MacIntosh, C; Johnson, S; Noonan, C; Barton, G; Sackley, C

    2017-10-01

    Pilot trial to compare prism therapy and visual search training, for homonymous hemianopia, to standard care (information only). Prospective, multicentre, parallel, single-blind, three-arm RCT across fifteen UK acute stroke units. Stroke survivors with homonymous hemianopia. Arm a (Fresnel prisms) for minimum 2 hours, 5 days per week over 6 weeks. Arm b (visual search training) for minimum 30 minutes, 5 days per week over 6 weeks. Arm c (standard care-information only). Adult stroke survivors (>18 years), stable hemianopia, visual acuity better than 0.5 logMAR, refractive error within ±5 dioptres, ability to read/understand English and provide consent. Primary outcomes were change in visual field area from baseline to 26 weeks and calculation of sample size for a definitive trial. Secondary measures included Rivermead Mobility Index, Visual Function Questionnaire 25/10, Nottingham Extended Activities of Daily Living, Euro Qual, Short Form-12 questionnaires and Radner reading ability. Measures were post-randomization at baseline and 6, 12 and 26 weeks. Randomization block lists stratified by site and partial/complete hemianopia. Allocations disclosed to patients. Primary outcome assessor blind to treatment allocation. Eighty-seven patients were recruited: 27-Fresnel prisms, 30-visual search training and 30-standard care; 69% male; mean age 69 years (SD 12). At 26 weeks, full results for 24, 24 and 22 patients, respectively, were compared to baseline. Sample size calculation for a definitive trial determined as 269 participants per arm for a 200 degree 2 visual field area change at 90% power. Non-significant relative change in area of visual field was 5%, 8% and 3.5%, respectively, for the three groups. Visual Function Questionnaire responses improved significantly from baseline to 26 weeks with visual search training (60 [SD 19] to 68.4 [SD 20]) compared to Fresnel prisms (68.5 [SD 16.4] to 68.2 [18.4]: 7% difference) and standard care (63.7 [SD 19.4] to 59.8 [SD 22.7]: 10% difference), P=.05. Related adverse events were common with Fresnel prisms (69.2%; typically headaches). No significant change occurred for area of visual field area across arms over follow-up. Visual search training had significant improvement in vision-related quality of life. Prism therapy produced adverse events in 69%. Visual search training results warrant further investigation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Deep Learning Predicts Correlation between a Functional Signature of Higher Visual Areas and Sparse Firing of Neurons.

    PubMed

    Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin

    2017-01-01

    Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas.

  15. Deep Learning Predicts Correlation between a Functional Signature of Higher Visual Areas and Sparse Firing of Neurons

    PubMed Central

    Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin

    2017-01-01

    Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas. PMID:29163117

  16. Visual Spatial Attention Training Improve Spatial Attention and Motor Control for Unilateral Neglect Patients.

    PubMed

    Wang, Wei; Ji, Xiangtong; Ni, Jun; Ye, Qian; Zhang, Sicong; Chen, Wenli; Bian, Rong; Yu, Cui; Zhang, Wenting; Shen, Guangyu; Machado, Sergio; Yuan, Tifei; Shan, Chunlei

    2015-01-01

    To compare the effect of visual spatial training on the spatial attention to that on motor control and to correlate the improvement of spatial attention to motor control progress after visual spatial training in subjects with unilateral spatial neglect (USN). 9 cases with USN after right cerebral stroke were randomly divided into Conventional treatment group + visual spatial attention and Conventional treatment group. The Conventional treatment group + visual spatial attention received conventional rehabilitation therapy (physical and occupational therapy) and visual spatial attention training (optokinetic stimulation and right half-field eye patching). The Conventional treatment group was only treated with conventional rehabilitation training (physical and occupational therapy). All patients were assessed by behavioral inattention test (BIT), Fugl-Meyer Assessment of motor function (FMA), equilibrium coordination test (ECT) and non-equilibrium coordination test (NCT) before and after 4 weeks treatment. Total scores in both groups (without visual spatial attention/with visual spatial attention) improved significantly (BIT: P=0.021/P=0.000, d=1.667/d=2.116, power=0.69/power=0.98, 95%CI[-0.8839,45.88]/95%CI=[16.96,92.64]; FMA: P=0.002/P=0.000, d=2.521/d=2.700, power=0.93/power=0.98, 95%CI[5.707,30.79]/95%CI=[16.06,53.94]; ECT: P=0.002/ P=0.000, d=2.031/d=1.354, power=0.90/power=0.17, 95%CI[3.380,42.61]/95%CI=[-1.478,39.08]; NCT: P=0.013/P=0.000, d=1.124/d=1.822, power=0.41/power=0.56, 95%CI[-7.980,37.48]/95%CI=[4.798,43.60],) after treatment. Among the 2 groups, the group with visual spatial attention significantly improved in BIT (P=0.003, d=3.103, power=1, 95%CI[15.68,48.92]), FMA of upper extremity (P=0.006, d=2.771, power=1, 95%CI[5.061,20.14]) and NCT (P=0.010, d=2.214, power=0.81-0.90, 95%CI[3.018,15.88]). Correlative analysis shows that the change of BIT scores is positively correlated to the change of FMA total score (r=0.77, P<;0.01), FMA of upper extremity (r=0.81, P<0.01), NCT (r=0.78, P<0.01). Four weeks visual spatial training could improve spatial attention as well as motor control functions in hemineglect patients. The improvement of motor function is positively correlated to the progresses of visual spatial functions after visual spatial attention training.

  17. Visual efficiency among teenaged athletes and non-athletes

    PubMed Central

    Omar, Rokiah; Kuan, Yau Meng; Zuhairi, Nurul Atikah; Manan, Faudziah Abd; Knight, Victor Feizal

    2017-01-01

    AIM To compare visual efficiency, specifically accom-modation, vergence, and oculomotor functions among athletes and non-athletes. METHODS A cross-sectional study on sports vision screening was used to evaluate the visual skills of 214 elementary students (107 athletes, 107 non-athletes), aged between 13 and 16y. The visual screening assessed visual parameters such as ocular motor alignment, accommodation, and vergence functions. RESULTS Mean visual parameters were compared between age-group matched athletes (mean age 14.82±0.98y) and non-athletes (mean age 15.00±1.04y). The refractive errors of all participants were corrected to maximal attainable best corrected visual acuity of logMAR 0.0. Accommodation function assessment evaluated amplitude of accommodation and accommodation facility. Vergence functions measured the near point of convergence, vergence facility, and distance fusional vergence at break and recovery point. Ocular motor alignment was not statistically significant between both groups. Athletes had a statistically significant amplitude of accommodation for both the right eye (t=2.30, P=0.02) and the left eye (t=1.99, P=0.05). Conversely, non-athletes had better accommodation facility (t=-2.54, P=0.01) and near point of convergence (t=4.39, P<0.001) when compared to athletes. Vergence facility was found to be better among athletes (t=2.47, P=0.01). Nevertheless, non-athletes were significantly better for both distance negative and positive fusional vergence. CONCLUSION Although the findings are still inconclusive as to whether athletes had superior visual skills as compared to non-athletes, it remains important to identify and elucidate the key visual skills needed by athletes in order for them to achieve higher performance in their sports. PMID:28944208

  18. The Effectiveness of Two Programs To Develop Visual Perception in Spanish Schoolchildren with Low Vision.

    ERIC Educational Resources Information Center

    Lopez-Justicia, Maria D.; Martos, Francisco J.

    1999-01-01

    This study compared improvements in visual function of 20 Spanish children with low vision, ages 4 to 6 years. Children received either the Barraga and Morris program or the Frostig program, or placebo control or no treatment. No significant differences between treatment groups were found. (DB)

  19. Learning to associate orientation with color in early visual areas by associative decoded fMRI neurofeedback

    PubMed Central

    Amano, Kaoru; Shibata, Kazuhisa; Kawato, Mitsuo; Sasaki, Yuka; Watanabe, Takeo

    2016-01-01

    Summary Associative learning is an essential brain process where the contingency of different items increases after training. Associative learning has been found to occur in many brain regions [1-4]. However, there is no clear evidence that associative learning of visual features occurs in early visual areas, although a number of studies have indicated that learning of a single visual feature (perceptual learning) involves early visual areas [5-8]. Here, via decoded functional magnetic resonance imaging (fMRI) neurofeedback, termed “DecNef” [9], we tested whether associative learning of color and orientation can be created in early visual areas. During three days' training, DecNef induced fMRI signal patterns that corresponded to a specific target color (red) mostly in early visual areas while a vertical achromatic grating was physically presented to participants. As a result, participants came to perceive “red” significantly more frequently than “green” in an achromatic vertical grating. This effect was also observed 3 to 5 months after the training. These results suggest that long-term associative learning of the two different visual features such as color and orientation was created most likely in early visual areas. This newly extended technique that induces associative learning is called “A(ssociative)-DecNef” and may be used as an important tool for understanding and modifying brain functions, since associations are fundamental and ubiquitous functions in the brain. PMID:27374335

  20. Combat Ration Network for Technology Implementation. Universal Benchtop Package Tester

    DTIC Science & Technology

    2006-10-01

    of three years of shelf life, but this packaging is susceptible to tears and holes during the manufacturing process. To avoid package integrity...characteristics, cannot provide a measurement of container contents. April 2003 - Precision Automation and PTI-USA expressed interest in manufacturing systems to... Noodles (185cc) • 212cc(+14.6%) • 209cc(+13.0%) – Chicken Brst. (150cc) • 160cc(+6.3%) • 154cc(+2.6%) • Water Trays – Tray A4 (185cc) • 200cc(+8.1

Top