Sample records for visual quality assessment

  1. Visual assessment of CPR quality during pediatric cardiac arrest: does point of view matter?

    PubMed

    Jones, Angela; Lin, Yiqun; Nettel-Aguirre, Alberto; Gilfoyle, Elaine; Cheng, Adam

    2015-05-01

    In many clinical settings, providers rely on visual assessment when delivering feedback on CPR quality. Little is known about the accuracy of visual assessment of CPR quality. We aimed to determine how accurate pediatric providers are in their visual assessment of CPR quality and to identify the optimal position relative to the patient for accurate CPR assessment. We videotaped high-quality CPR (based on 2010 American Heart Association guidelines) and 3 variations of poor quality CPR in a simulated resuscitation, filmed from the foot, head and the side of the manikin. Participants watched 12 videos and completed a questionnaire to assess CPR quality. One hundred and twenty-five participants were recruited. The overall accuracy of visual assessment of CPR quality was 65.6%. Accuracy was better from the side (70.8%) and foot (68.8%) of the bed when compared to the head of the bed (57.2%; p<0.001). The side was the best position for assessing depth (p<0.001). Rate assessment was equivalent between positions (p=0.58). The side and foot of the bed were superior to the head when assessing chest recoil (p<0.001). Factors associated with increased accuracy in visual assessment of CPR quality included recent CPR course completion (p=0.034) and involvement in more cardiac arrests as a team member (p=0.003). Healthcare providers struggle to accurately assess the quality of CPR using visual assessment. If visual assessment is being used, providers should stand at the side of the bed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. A new approach to subjectively assess quality of plenoptic content

    NASA Astrophysics Data System (ADS)

    Viola, Irene; Řeřábek, Martin; Ebrahimi, Touradj

    2016-09-01

    Plenoptic content is becoming increasingly popular thanks to the availability of acquisition and display devices. Thanks to image-based rendering techniques, a plenoptic content can be rendered in real time in an interactive manner allowing virtual navigation through the captured scenes. This way of content consumption enables new experiences, and therefore introduces several challenges in terms of plenoptic data processing, transmission and consequently visual quality evaluation. In this paper, we propose a new methodology to subjectively assess the visual quality of plenoptic content. We also introduce a prototype software to perform subjective quality assessment according to the proposed methodology. The proposed methodology is further applied to assess the visual quality of a light field compression algorithm. Results show that this methodology can be successfully used to assess the visual quality of plenoptic content.

  3. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images.

    PubMed

    Mraity, Hussien A A B; England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.

  4. Development and validation of a visual grading scale for assessing image quality of AP pelvis radiographic images

    PubMed Central

    England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter

    2016-01-01

    Objective: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Methods: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. Results: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). Conclusion: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. Advances in knowledge: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality. PMID:26943836

  5. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system.

    PubMed

    Demehri, S; Muhit, A; Zbijewski, W; Stayman, J W; Yorkston, J; Packard, N; Senn, R; Yang, D; Foos, D; Thawait, G K; Fayad, L M; Chhabra, A; Carrino, J A; Siewerdsen, J H

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80 kVp-108mAs for CBCT; 120 kVp- 300 mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated "excellent" or "good" (median scores 5 and 4) for "bone" and "soft tissue" visualization tasks. Hand CBCT images were rated "excellent" or "adequate" (median scores 5 and 3) for "bone" and "soft tissue" visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ~ 0.26-0.92), and interobserver agreement was fair to moderate (κ ~ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. • CBCT provided adequate image quality for diagnostic tasks in extremity imaging. • CBCT images were "excellent" for "bone" and "good/adequate" for "soft tissue" visualization tasks. • CBCT image quality was equivalent/superior to MDCT for bone visualization tasks.

  6. Multiscale visual quality assessment for cluster analysis with self-organizing maps

    NASA Astrophysics Data System (ADS)

    Bernard, Jürgen; von Landesberger, Tatiana; Bremm, Sebastian; Schreck, Tobias

    2011-01-01

    Cluster analysis is an important data mining technique for analyzing large amounts of data, reducing many objects to a limited number of clusters. Cluster visualization techniques aim at supporting the user in better understanding the characteristics and relationships among the found clusters. While promising approaches to visual cluster analysis already exist, these usually fall short of incorporating the quality of the obtained clustering results. However, due to the nature of the clustering process, quality plays an important aspect, as for most practical data sets, typically many different clusterings are possible. Being aware of clustering quality is important to judge the expressiveness of a given cluster visualization, or to adjust the clustering process with refined parameters, among others. In this work, we present an encompassing suite of visual tools for quality assessment of an important visual cluster algorithm, namely, the Self-Organizing Map (SOM) technique. We define, measure, and visualize the notion of SOM cluster quality along a hierarchy of cluster abstractions. The quality abstractions range from simple scalar-valued quality scores up to the structural comparison of a given SOM clustering with output of additional supportive clustering methods. The suite of methods allows the user to assess the SOM quality on the appropriate abstraction level, and arrive at improved clustering results. We implement our tools in an integrated system, apply it on experimental data sets, and show its applicability.

  7. Assessment of visual landscape quality using IKONOS imagery.

    PubMed

    Ozkan, Ulas Yunus

    2014-07-01

    The assessment of visual landscape quality is of importance to the management of urban woodlands. Satellite remote sensing may be used for this purpose as a substitute for traditional survey techniques that are both labour-intensive and time-consuming. This study examines the association between the quality of the perceived visual landscape in urban woodlands and texture measures extracted from IKONOS satellite data, which features 4-m spatial resolution and four spectral bands. The study was conducted in the woodlands of Istanbul (the most important element of urban mosaic) lying along both shores of the Bosporus Strait. The visual quality assessment applied in this study is based on the perceptual approach and was performed via a survey of expressed preferences. For this purpose, representative photographs of real scenery were used to elicit observers' preferences. A slide show comprising 33 images was presented to a group of 153 volunteers (all undergraduate students), and they were asked to rate the visual quality of each on a 10-point scale (1 for very low visual quality, 10 for very high). Average visual quality scores were calculated for landscape. Texture measures were acquired using the two methods: pixel-based and object-based. Pixel-based texture measures were extracted from the first principle component (PC1) image. Object-based texture measures were extracted by using the original four bands. The association between image texture measures and perceived visual landscape quality was tested via Pearson's correlation coefficient. The analysis found a strong linear association between image texture measures and visual quality. The highest correlation coefficient was calculated between standard deviation of gray levels (SDGL) (one of the pixel-based texture measures) and visual quality (r = 0.82, P < 0.05). The results showed that perceived visual quality of urban woodland landscapes can be estimated by using texture measures extracted from satellite data in combination with appropriate modelling techniques.

  8. CLINICAL AUDIT OF IMAGE QUALITY IN RADIOLOGY USING VISUAL GRADING CHARACTERISTICS ANALYSIS.

    PubMed

    Tesselaar, Erik; Dahlström, Nils; Sandborg, Michael

    2016-06-01

    The aim of this work was to assess whether an audit of clinical image quality could be efficiently implemented within a limited time frame using visual grading characteristics (VGC) analysis. Lumbar spine radiography, bedside chest radiography and abdominal CT were selected. For each examination, images were acquired or reconstructed in two ways. Twenty images per examination were assessed by 40 radiology residents using visual grading of image criteria. The results were analysed using VGC. Inter-observer reliability was assessed. The results of the visual grading analysis were consistent with expected outcomes. The inter-observer reliability was moderate to good and correlated with perceived image quality (r(2) = 0.47). The median observation time per image or image series was within 2 min. These results suggest that the use of visual grading of image criteria to assess the quality of radiographs provides a rapid method for performing an image quality audit in a clinical environment. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Video quality assessment using a statistical model of human visual speed perception.

    PubMed

    Wang, Zhou; Li, Qiang

    2007-12-01

    Motion is one of the most important types of information contained in natural video, but direct use of motion information in the design of video quality assessment algorithms has not been deeply investigated. Here we propose to incorporate a recent model of human visual speed perception [Nat. Neurosci. 9, 578 (2006)] and model visual perception in an information communication framework. This allows us to estimate both the motion information content and the perceptual uncertainty in video signals. Improved video quality assessment algorithms are obtained by incorporating the model as spatiotemporal weighting factors, where the weight increases with the information content and decreases with the perceptual uncertainty. Consistent improvement over existing video quality assessment algorithms is observed in our validation with the video quality experts group Phase I test data set.

  10. Automated estimation of image quality for coronary computed tomographic angiography using machine learning.

    PubMed

    Nakanishi, Rine; Sankaran, Sethuraman; Grady, Leo; Malpeso, Jenifer; Yousfi, Razik; Osawa, Kazuhiro; Ceponiene, Indre; Nazarat, Negin; Rahmani, Sina; Kissel, Kendall; Jayawardena, Eranthi; Dailing, Christopher; Zarins, Christopher; Koo, Bon-Kwon; Min, James K; Taylor, Charles A; Budoff, Matthew J

    2018-03-23

    Our goal was to evaluate the efficacy of a fully automated method for assessing the image quality (IQ) of coronary computed tomography angiography (CCTA). The machine learning method was trained using 75 CCTA studies by mapping features (noise, contrast, misregistration scores, and un-interpretability index) to an IQ score based on manual ground truth data. The automated method was validated on a set of 50 CCTA studies and subsequently tested on a new set of 172 CCTA studies against visual IQ scores on a 5-point Likert scale. The area under the curve in the validation set was 0.96. In the 172 CCTA studies, our method yielded a Cohen's kappa statistic for the agreement between automated and visual IQ assessment of 0.67 (p < 0.01). In the group where good to excellent (n = 163), fair (n = 6), and poor visual IQ scores (n = 3) were graded, 155, 5, and 2 of the patients received an automated IQ score > 50 %, respectively. Fully automated assessment of the IQ of CCTA data sets by machine learning was reproducible and provided similar results compared with visual analysis within the limits of inter-operator variability. • The proposed method enables automated and reproducible image quality assessment. • Machine learning and visual assessments yielded comparable estimates of image quality. • Automated assessment potentially allows for more standardised image quality. • Image quality assessment enables standardization of clinical trial results across different datasets.

  11. Stress wave sorting of red maple logs for structural quality

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Brian Brashaw; Karl Englund; Michael Wolcott

    2004-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  12. Standardizing Quality Assessment of Fused Remotely Sensed Images

    NASA Astrophysics Data System (ADS)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  13. Image quality assessment by preprocessing and full reference model combination

    NASA Astrophysics Data System (ADS)

    Bianco, S.; Ciocca, G.; Marini, F.; Schettini, R.

    2009-01-01

    This paper focuses on full-reference image quality assessment and presents different computational strategies aimed to improve the robustness and accuracy of some well known and widely used state of the art models, namely the Structural Similarity approach (SSIM) by Wang and Bovik and the S-CIELAB spatial-color model by Zhang and Wandell. We investigate the hypothesis that combining error images with a visual attention model could allow a better fit of the psycho-visual data of the LIVE Image Quality assessment Database Release 2. We show that the proposed quality assessment metric better correlates with the experimental data.

  14. Perceptual visual dysfunction, physical impairment and quality of life in Bangladeshi children with cerebral palsy.

    PubMed

    Mitry, D; Williams, C; Northstone, K; Akter, A; Jewel, J; Khan, N; Muhit, M; Gilbert, C E; Bowman, R

    2016-09-01

    Cerebral palsy (CP) is the most common cause of motor disability in children and is often accompanied by sensory and/or cognitive impairment. The aim of this study was to characterise visual acuity impairment, perceptual visual dysfunction (PVD) and physical disability in a community-based sample of Bangladeshi children with CP and to assess the impact of these factors on the quality of life of the children. A key informant study was used to recruit children with CP from Sirajganj district. Gross Motor Function Classification System (GMFCS) levels and visual impairment were assessed by a physiotherapist and an optometrist, respectively. Assessments of visual perception were performed and standardised questionnaires were administered to each child's main carer to elicit indicators of PVD and parent-reported health-related quality of life. A generalised linear regression analysis was conducted to assess the determinants of the quality of life scores. 180 children were recruited. The median age was 8 years (IQR: 6-11 years); 112 (62%) were male; 57 (32%) had visual acuity impairment and 95 (53%) had some parent-reported PVD. In analyses adjusted for age, sex, GMFCS and acuity impairment, visual attention (p<0.001) and recognition/navigation (p<0.001) were associated with total health-related quality of life, and there were similar trends for total PVD score (p=0.006) and visual search (p=0.020). PVD is an important contributor in reducing quality of life in children with CP, independent of motor disability and acuity impairment. Better characterisation of PVD is important to help design interventions for affected children, which may improve their quality of life. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Visual acuity and quality of life in dry eye disease: Proceedings of the OCEAN group meeting.

    PubMed

    Benítez-Del-Castillo, José; Labetoulle, Marc; Baudouin, Christophe; Rolando, Maurizio; Akova, Yonca A; Aragona, Pasquale; Geerling, Gerd; Merayo-Lloves, Jesús; Messmer, Elisabeth M; Boboridis, Kostas

    2017-04-01

    Dry eye disease (DED) results in tear film instability and hyperosmolarity, inflammation of the ocular surface and, ultimately, visual disturbance that can significantly impact a patient's quality of life. The effects on visual acuity result in difficulties with driving, reading and computer use and negatively impact psychological health. These effects also extend to the workplace, with a loss of productivity and quality of work causing substantial economic losses. The effects of DED and the impact on vision experienced by patients may not be given sufficient importance by ophthalmologists. Functional visual acuity (FVA) is a measure of visual acuity after sustained eye opening without blinking for at least 10 s and mimics the sustained visual acuity of daily life. Measuring dynamic FVA allows the detection of impaired visual function in patients with DED who may display normal conventional visual acuity. There are currently several tests and methods that can be used to measure dynamic visual function: the SSC-350 FVA measurement system, assessment of best-corrected visual acuity decay using the interblink visual acuity decay test, serial measurements of ocular and corneal higher order aberrations, and measurement of dynamic vision quality using the Optical Quality Analysis System. Although the equipment for these methods may be too large or unaffordable for use in clinical practice, FVA testing is an important assessment for DED. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Visual quality assessment of alternative silvicultural practices in upland hardwood management

    Treesearch

    Tim McDonald; Bryce Stokes

    1997-01-01

    Visual impacts of forest operations are of increasing concern to forest managers. Tools are available for evaluating, and potentially avoiding, problems in visual quality resulting from poorly designed harvest unit boundaries. One of these visualization tools is applied in comparing various harvest unit shape alternatives in an upland hardwood stand on steeply sloping...

  17. Criteria for assessment of bridge aesthetic and visual quality

    NASA Astrophysics Data System (ADS)

    Rozentale, I.; Paeglitis, A.

    2017-10-01

    The bridge designers should find an ideal balance between structure, economy, buildability, aesthetics, durability and harmony with industrial or natural landscape. During the last years, the society has adopted documents providing procedures for evaluation of the impact of the structural appearance on surrounding landscape. The European Landscape Convention defines the landscape as an area perceived by people, whose character is the result of the action and interaction of natural and/or human factors. The Convention indicates the methods for clear and objective assessment of the landscape’s visual qualities. The esthetical qualities of bridge structures, appearance and attraction should satisfy not only the technicians - engineers and architects, but mostly the surrounding population. Each of these groups has a different perception of esthetical qualities of structure. Many authors have used different methods and criteria for assessment of bridge aesthetics. The aim of this paper is to provide an overview of the bridge aesthetic and visual quality assessment methods and criteria.

  18. Nondestructive evaluation for sorting red maple logs

    Treesearch

    Xiping Wang; Robert J. Ross; David W. Green; Karl Englund; Michael Wolcott

    2000-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  19. Building conservation base on assessment of facade quality on Basuki Rachmat Street, Malang

    NASA Astrophysics Data System (ADS)

    Kurniawan, E. B.; Putri, R. Y. A.; Wardhani, D. K.

    2017-06-01

    Visual quality covers aspects of imageability which is associated with visual system and the element of distinction. Within a visual system of specific area, the physical quality may lead to a strong image. Here, the physical quality is one of important that make urban aesthetic. Build a discussion toward visual system of urban area, this paper aim is to identify the influencing factors in defining the façade’s visual quality of heritage buildings at Jend. Basuki Rahmat Street, Malang City, East Java-Indonesia. This Street is a main road of Malang city center that was built by Dutch colonial government. It was designed by IR. Thomas Kartsten. It was known as one of Malang area that have good visual quality. In order to idenfity the influencing factors, this paper conducts Multiple linear regression as a tools of analysis. The examined potential factors are resulted from of architecture and urban design expert’s assessment to each building’s segment at Jend. Basuki Rahmat. Finally, this paper reveals that the influencing factors are color, rhythm, and proportion. This is demonstrated by the results model: Visual quality (Y) = 0.304 + 0.21 Colors(X5) + 0.221 rhythm (X6) + 0.304 proportion (X7). Furthermore, the recommendation of the building facade will be made based on this model and study of historical and typology building in Basuki Rachmat Street.

  20. Information theoretical assessment of visual communication with subband coding

    NASA Astrophysics Data System (ADS)

    Rahman, Zia-ur; Fales, Carl L.; Huck, Friedrich O.

    1994-09-01

    A well-designed visual communication channel is one which transmits the most information about a radiance field with the fewest artifacts. The role of image processing, encoding and restoration is to improve the quality of visual communication channels by minimizing the error in the transmitted data. Conventionally this role has been analyzed strictly in the digital domain neglecting the effects of image-gathering and image-display devices on the quality of the image. This results in the design of a visual communication channel which is `suboptimal.' We propose an end-to-end assessment of the imaging process which incorporates the influences of these devices in the design of the encoder and the restoration process. This assessment combines Shannon's communication theory with Wiener's restoration filter and with the critical design factors of the image gathering and display devices, thus providing the metrics needed to quantify and optimize the end-to-end performance of the visual communication channel. Results show that the design of the image-gathering device plays a significant role in determining the quality of the visual communication channel and in designing the analysis filters for subband encoding.

  1. Automated Assessment of Visual Quality of Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Ellis, Stephen R. (Technical Monitor)

    1997-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images[1-4]. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  2. Impacts of soil moisture content on visual soil evaluation

    NASA Astrophysics Data System (ADS)

    Emmet-Booth, Jeremy; Forristal, Dermot; Fenton, Owen; Bondi, Giulia; Creamer, Rachel; Holden, Nick

    2017-04-01

    Visual Soil Examination and Evaluation (VSE) techniques offer tools for soil quality assessment. They involve the visual and tactile assessment of soil properties such as aggregate size and shape, porosity, redox morphology, soil colour and smell. An increasing body of research has demonstrated the reliability and utility of VSE techniques. However a number of limitations have been identified, including the potential impact of soil moisture variation during sampling. As part of a national survey of grassland soil quality in Ireland, an evaluation of the impact of soil moisture on two widely used VSE techniques was conducted. The techniques were Visual Evaluation of Soil Structure (VESS) (Guimarães et al., 2011) and Visual Soil Assessment (VSA) (Shepherd, 2009). Both generate summarising numeric scores that indicate soil structural quality, though employ different scoring mechanisms. The former requires the assessment of properties concurrently and the latter separately. Both methods were deployed on 20 sites across Ireland representing a range of soils. Additional samples were taken for soil volumetric water (θ) determination at 5-10 and 10-20 cm depth. No significant correlation was observed between θ 5-10 cm and either VSE technique. However, VESS scores were significantly related to θ 10-20 cm (rs = 0.40, sig = 0.02) while VSA scores were not (rs = -0.33, sig = 0.06). VESS and VSA scores can be grouped into quality classifications (good, moderate and poor). No significant mean difference was observed between θ 5-10 cm or θ 10-20 cm according to quality classification by either method. It was concluded that VESS scores may be affected by soil moisture variation while VSA appear unaffected. The different scoring mechanisms, where the separate assessment and scoring of individual properties employed by VSA, may limit soil moisture effects. However, moisture content appears not to affect overall structural quality classification by either method. References Guimarães, R.M.C., Ball, B.C. & Tormena, C.A. 2011. Improvements in the visual evaluation of soil structure, Soil Use and Management, 27, 3: 395-403 Shepherd, G.T. 2009. Visual Soil Assessment. Field guide for pastoral grazing and cropping on flat to rolling country. 2nd edn. Horizons regional council, New Zealand.

  3. Predictors of vision impairment in Multiple Sclerosis.

    PubMed

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  4. The Q-Sort method: use in landscape assessment research and landscape planning

    Treesearch

    David G. Pitt; Ervin H. Zube

    1979-01-01

    The assessment of visual quality inherently involves the measurement of perceptual response to landscape. The Q-Sort Method is a psychometric technique which produces reliable and valid interval measurements of people's perceptions of landscape visual quality as depicted in photographs. It is readily understood by participants across a wide range of age groups and...

  5. The association of visually-assessed quality of movement during jump-landing with ankle dorsiflexion range-of-motion and hip abductor muscle strength among healthy female athletes.

    PubMed

    Rabin, Alon; Einstein, Ofira; Kozol, Zvi

    2018-05-01

    To explore the association between ankle dorsiflexion (DF) range of motion (ROM), and hip abductor muscle strength, to visually-assessed quality of movement during jump-landing. Cross-sectional. Gymnasium of participating teams. 37 female volleyball players. Quality of movement in the frontal-plane, sagittal-plane, and overall (both planes) was visually rated as "good/moderate" or "poor". Weight-bearing Ankle DF ROM and hip abductor muscle strength were compared between participants with differing quality of movement. Weight-bearing DF ROM on both sides was decreased among participants with "poor" sagittal-plane quality of movement (dominant side: 50.8° versus 43.6°, P = .02; non-dominant side: 54.6° versus 45.9°, P = .01), as well as among participants with an overall "poor" quality of movement (dominant side: 51.8° versus 44.0°, P < .01; non-dominant side: 56.5° versus 45.1°, P < .01). Weight-bearing ankle DF on the non-dominant side was decreased among participants with a "poor" frontal-plane quality of movement (53.9° versus 46.0°, P = .02). No differences in hip abductor muscle strength were noted between participants with differing quality of movement. Visual assessment of jump-landing can detect differences in quality of movement that are associated with ankle DF ROM. Clinicians observing a poor quality of movement may wish to assess ankle DF ROM. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Quality labeled faces in the wild (QLFW): a database for studying face recognition in real-world environments

    NASA Astrophysics Data System (ADS)

    Karam, Lina J.; Zhu, Tong

    2015-03-01

    The varying quality of face images is an important challenge that limits the effectiveness of face recognition technology when applied in real-world applications. Existing face image databases do not consider the effect of distortions that commonly occur in real-world environments. This database (QLFW) represents an initial attempt to provide a set of labeled face images spanning the wide range of quality, from no perceived impairment to strong perceived impairment for face detection and face recognition applications. Types of impairment include JPEG2000 compression, JPEG compression, additive white noise, Gaussian blur and contrast change. Subjective experiments are conducted to assess the perceived visual quality of faces under different levels and types of distortions and also to assess the human recognition performance under the considered distortions. One goal of this work is to enable automated performance evaluation of face recognition technologies in the presence of different types and levels of visual distortions. This will consequently enable the development of face recognition systems that can operate reliably on real-world visual content in the presence of real-world visual distortions. Another goal is to enable the development and assessment of visual quality metrics for face images and for face detection and recognition applications.

  7. Assessment of visual communication by information theory

    NASA Astrophysics Data System (ADS)

    Huck, Friedrich O.; Fales, Carl L.

    1994-01-01

    This assessment of visual communication integrates the optical design of the image-gathering device with the digital processing for image coding and restoration. Results show that informationally optimized image gathering ordinarily can be relied upon to maximize the information efficiency of decorrelated data and the visual quality of optimally restored images.

  8. Visual land-use compatibility and scenic-resource quality

    Treesearch

    William G. Hendrix

    1977-01-01

    The effect that land-use relationships have upon perceived quality of the visual landscape is discussed, and a case is made for expansion of fit-misfit theory into what has been called visual land-use compatibility. An assessment methodology that was designed to test people's perceptions of land-use relationships is presented and the results are discussed.

  9. No-reference quality assessment based on visual perception

    NASA Astrophysics Data System (ADS)

    Li, Junshan; Yang, Yawei; Hu, Shuangyan; Zhang, Jiao

    2014-11-01

    The visual quality assessment of images/videos is an ongoing hot research topic, which has become more and more important for numerous image and video processing applications with the rapid development of digital imaging and communication technologies. The goal of image quality assessment (IQA) algorithms is to automatically assess the quality of images/videos in agreement with human quality judgments. Up to now, two kinds of models have been used for IQA, namely full-reference (FR) and no-reference (NR) models. For FR models, IQA algorithms interpret image quality as fidelity or similarity with a perfect image in some perceptual space. However, the reference image is not available in many practical applications, and a NR IQA approach is desired. Considering natural vision as optimized by the millions of years of evolutionary pressure, many methods attempt to achieve consistency in quality prediction by modeling salient physiological and psychological features of the human visual system (HVS). To reach this goal, researchers try to simulate HVS with image sparsity coding and supervised machine learning, which are two main features of HVS. A typical HVS captures the scenes by sparsity coding, and uses experienced knowledge to apperceive objects. In this paper, we propose a novel IQA approach based on visual perception. Firstly, a standard model of HVS is studied and analyzed, and the sparse representation of image is accomplished with the model; and then, the mapping correlation between sparse codes and subjective quality scores is trained with the regression technique of least squaresupport vector machine (LS-SVM), which gains the regressor that can predict the image quality; the visual metric of image is predicted with the trained regressor at last. We validate the performance of proposed approach on Laboratory for Image and Video Engineering (LIVE) database, the specific contents of the type of distortions present in the database are: 227 images of JPEG2000, 233 images of JPEG, 174 images of White Noise, 174 images of Gaussian Blur, 174 images of Fast Fading. The database includes subjective differential mean opinion score (DMOS) for each image. The experimental results show that the proposed approach not only can assess many kinds of distorted images quality, but also exhibits a superior accuracy and monotonicity.

  10. Accuracy of quantitative visual soil assessment

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Maricke; Heuvelink, Gerard; Stoorvogel, Jetse; Wallinga, Jakob; de Boer, Imke; van Dam, Jos; van Essen, Everhard; Moolenaar, Simon; Verhoeven, Frank; Stoof, Cathelijne

    2016-04-01

    Visual soil assessment (VSA) is a method to assess soil quality visually, when standing in the field. VSA is increasingly used by farmers, farm organisations and companies, because it is rapid and cost-effective, and because looking at soil provides understanding about soil functioning. Often VSA is regarded as subjective, so there is a need to verify VSA. Also, many VSAs have not been fine-tuned for contrasting soil types. This could lead to wrong interpretation of soil quality and soil functioning when contrasting sites are compared to each other. We wanted to assess accuracy of VSA, while taking into account soil type. The first objective was to test whether quantitative visual field observations, which form the basis in many VSAs, could be validated with standardized field or laboratory measurements. The second objective was to assess whether quantitative visual field observations are reproducible, when used by observers with contrasting backgrounds. For the validation study, we made quantitative visual observations at 26 cattle farms. Farms were located at sand, clay and peat soils in the North Friesian Woodlands, the Netherlands. Quantitative visual observations evaluated were grass cover, number of biopores, number of roots, soil colour, soil structure, number of earthworms, number of gley mottles and soil compaction. Linear regression analysis showed that four out of eight quantitative visual observations could be well validated with standardized field or laboratory measurements. The following quantitative visual observations correlated well with standardized field or laboratory measurements: grass cover with classified images of surface cover; number of roots with root dry weight; amount of large structure elements with mean weight diameter; and soil colour with soil organic matter content. Correlation coefficients were greater than 0.3, from which half of the correlations were significant. For the reproducibility study, a group of 9 soil scientists and 7 farmers carried out quantitative visual observations all independently from each other. All observers assessed five sites, having a sand, peat or clay soil. For almost all quantitative visual observations the spread of observed values was low (coefficient of variation < 1.0), except for the number of biopores and gley mottles. Furthermore, farmers' observed mean values were significantly higher than soil scientists' mean values, for soil structure, amount of gley mottles and compaction. This study showed that VSA could be a valuable tool to assess soil quality. Subjectivity, due to the background of the observer, might influence the outcome of visual assessment of some soil properties. In countries where soil analyses can easily be carried out, VSA might be a good replenishment to available soil chemical analyses, and in countries where it is not feasible to carry out soil analyses, VSA might be a good start to assess soil quality.

  11. Quality of Life and Mental State After Sight Restoration by Corneal Transplantation.

    PubMed

    Drzyzga, Karolina; Krupka-Matuszczyk, Irena; Drzyzga, Łukasz; Mrukwa-Kominek, Ewa; Kucia, Krzysztof

    2016-01-01

    Quality of life has frequently been reported to improve after corneal transplantation. However, mental status before and after surgery has until now been less well investigated. The aim of this study was to investigate quality of life and mental status before and after corneal transplantation including postoperative immunosuppression and visual acuity. A total of 45 patients were assessed before, and 3 weeks and 4 months after transplantation using the following questionnaires: Visual Function Questionnaire, Beck Depression Inventory, and Hamilton Anxiety Rating Scale. Assessment included a visual acuity test using the logMAR chart, and recognition of the role of postoperative immunosuppression. Finally, patients were asked if they would be willing to have the surgery again. In the candidates for surgery, quality of life was reduced, and symptoms of depression and anxiety were present. Corneal transplantation improved their quality of life and reduced symptoms of depression and anxiety. Changes in quality of life and in mental state were associated with a change in visual acuity in the grafted eye. Higher doses of prednisone were associated with a worse quality of life and with more severe symptoms of depression and anxiety after transplantation. Further, 82.5% of patients would have the surgery again. Assessment for psychiatric symptoms should be considered in individuals facing corneal surgery. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  12. Perceptual full-reference quality assessment of stereoscopic images by considering binocular visual characteristics.

    PubMed

    Shao, Feng; Lin, Weisi; Gu, Shanbo; Jiang, Gangyi; Srikanthan, Thambipillai

    2013-05-01

    Perceptual quality assessment is a challenging issue in 3D signal processing research. It is important to study 3D signal directly instead of studying simple extension of the 2D metrics directly to the 3D case as in some previous studies. In this paper, we propose a new perceptual full-reference quality assessment metric of stereoscopic images by considering the binocular visual characteristics. The major technical contribution of this paper is that the binocular perception and combination properties are considered in quality assessment. To be more specific, we first perform left-right consistency checks and compare matching error between the corresponding pixels in binocular disparity calculation, and classify the stereoscopic images into non-corresponding, binocular fusion, and binocular suppression regions. Also, local phase and local amplitude maps are extracted from the original and distorted stereoscopic images as features in quality assessment. Then, each region is evaluated independently by considering its binocular perception property, and all evaluation results are integrated into an overall score. Besides, a binocular just noticeable difference model is used to reflect the visual sensitivity for the binocular fusion and suppression regions. Experimental results show that compared with the relevant existing metrics, the proposed metric can achieve higher consistency with subjective assessment of stereoscopic images.

  13. Pedestrian visual recommendation in Kertanegara - Semeru corridor in Malang City

    NASA Astrophysics Data System (ADS)

    Cosalia, V. B.

    2017-06-01

    Streetscape could be the first impression to see an urban area. One of the streerscape that should be attended to it is corridor of Jl. Kertanegara - Semeru since at that corridor is the road corridor having the strong caracter also as the one of the main axes in Malang city. This research is aim knowing the visual quality also the exact structuring rcommendation for Jl. Kertanegara - Semeru based on pedestrian’s visual. The methode used to this research is Scenic Beauty Estimation (SBE) and used historic study. There is several variables used, they are scale space, visual flexibility, beauty, emphasis, balance and dominant. Based on those variable the pedestrians as a respondent doing the assessment. Based on the result of SBE have been done, it is showed that the visual quality in Corridor Kertanegara Semeru is well enough since the result showed that there are 10 photos in low visual quality in Jl. Semeru and 14 photos in high visual quality in Jl. Kertanegara, Jl. Tugu dan Jl. Kahuripan. By the historic study and based on high visual quality reference doing the structuring recommendation in part of landscape having the low visual quality.

  14. On the assessment of visual communication by information theory

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Fales, Carl L.

    1993-01-01

    This assessment of visual communication integrates the optical design of the image-gathering device with the digital processing for image coding and restoration. Results show that informationally optimized image gathering ordinarily can be relied upon to maximize the information efficiency of decorrelated data and the visual quality of optimally restored images.

  15. A no-reference image and video visual quality metric based on machine learning

    NASA Astrophysics Data System (ADS)

    Frantc, Vladimir; Voronin, Viacheslav; Semenishchev, Evgenii; Minkin, Maxim; Delov, Aliy

    2018-04-01

    The paper presents a novel visual quality metric for lossy compressed video quality assessment. High degree of correlation with subjective estimations of quality is due to using of a convolutional neural network trained on a large amount of pairs video sequence-subjective quality score. We demonstrate how our predicted no-reference quality metric correlates with qualitative opinion in a human observer study. Results are shown on the EVVQ dataset with comparison existing approaches.

  16. Human visual system consistent quality assessment for remote sensing image fusion

    NASA Astrophysics Data System (ADS)

    Liu, Jun; Huang, Junyi; Liu, Shuguang; Li, Huali; Zhou, Qiming; Liu, Junchen

    2015-07-01

    Quality assessment for image fusion is essential for remote sensing application. Generally used indices require a high spatial resolution multispectral (MS) image for reference, which is not always readily available. Meanwhile, the fusion quality assessments using these indices may not be consistent with the Human Visual System (HVS). As an attempt to overcome this requirement and inconsistency, this paper proposes an HVS-consistent image fusion quality assessment index at the highest resolution without a reference MS image using Gaussian Scale Space (GSS) technology that could simulate the HVS. The spatial details and spectral information of original and fused images are first separated in GSS, and the qualities are evaluated using the proposed spatial and spectral quality index respectively. The overall quality is determined without a reference MS image by a combination of the proposed two indices. Experimental results on various remote sensing images indicate that the proposed index is more consistent with HVS evaluation compared with other widely used indices that may or may not require reference images.

  17. Visuals in Geography Textbooks: Categorization of Types and Assessment of Their Instructional Qualities

    ERIC Educational Resources Information Center

    Janko, Tomáš; Knecht, Petr

    2013-01-01

    The article focuses on the issue of visuals in geography textbooks and their assessment. The issue is explained from the perspective of educational and cognitive psychological theory and the theory of textbooks. The general purpose of the presented research is to develop a research instrument for categorising the types of visuals in geography…

  18. Video quality assessment method motivated by human visual perception

    NASA Astrophysics Data System (ADS)

    He, Meiling; Jiang, Gangyi; Yu, Mei; Song, Yang; Peng, Zongju; Shao, Feng

    2016-11-01

    Research on video quality assessment (VQA) plays a crucial role in improving the efficiency of video coding and the performance of video processing. It is well acknowledged that the motion energy model generates motion energy responses in a middle temporal area by simulating the receptive field of neurons in V1 for the motion perception of the human visual system. Motivated by the biological evidence for the visual motion perception, a VQA method is proposed in this paper, which comprises the motion perception quality index and the spatial index. To be more specific, the motion energy model is applied to evaluate the temporal distortion severity of each frequency component generated from the difference of Gaussian filter bank, which produces the motion perception quality index, and the gradient similarity measure is used to evaluate the spatial distortion of the video sequence to get the spatial quality index. The experimental results of the LIVE, CSIQ, and IVP video databases demonstrate that the random forests regression technique trained by the generated quality indices is highly correspondent to human visual perception and has many significant improvements than comparable well-performing methods. The proposed method has higher consistency with subjective perception and higher generalization capability.

  19. A novel no-reference objective stereoscopic video quality assessment method based on visual saliency analysis

    NASA Astrophysics Data System (ADS)

    Yang, Xinyan; Zhao, Wei; Ye, Long; Zhang, Qin

    2017-07-01

    This paper proposes a no-reference objective stereoscopic video quality assessment method with the motivation that making the effect of objective experiments close to that of subjective way. We believe that the image regions with different visual salient degree should not have the same weights when designing an assessment metric. Therefore, we firstly use GBVS algorithm to each frame pairs and separate both the left and right viewing images into the regions with strong, general and week saliency. Besides, local feature information like blockiness, zero-crossing and depth are extracted and combined with a mathematical model to calculate a quality assessment score. Regions with different salient degree are assigned with different weights in the mathematical model. Experiment results demonstrate the superiority of our method compared with the existed state-of-the-art no-reference objective Stereoscopic video quality assessment methods.

  20. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure

    PubMed Central

    Stringham, James M.; Stringham, Nicole T.; O’Brien, Kevin J.

    2017-01-01

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased “screen time” (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months’ supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures (p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo (p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation. PMID:28661438

  1. Macular Carotenoid Supplementation Improves Visual Performance, Sleep Quality, and Adverse Physical Symptoms in Those with High Screen Time Exposure.

    PubMed

    Stringham, James M; Stringham, Nicole T; O'Brien, Kevin J

    2017-06-29

    The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased "screen time" (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months' supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures ( p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo ( p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation.

  2. Visual impairment, visual functioning, and quality of life assessments in patients with glaucoma.

    PubMed Central

    Parrish, R K

    1996-01-01

    BACKGROUND/PURPOSE: To determine the relation between visual impairment, visual functioning, and the global quality of life in patients with glaucoma. METHODS: Visual impairment, defined with the American Medical Association Guides to the Evaluation of Permanent Impairment; visual functioning, measured with the VF-14 and the Field Test Version of the National Eye Institute-Visual Functioning Questionnaire (NEI-VFQ); and the global quality of life, assessed with the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), were determined in 147 consecutive patients with glaucoma. RESULTS: None of the SF-36 domains demonstrated more than a weak correlation with visual impairment. The VF-14 scores were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual field impairment; vision specific social functioning, near activities, vision specific role difficulties, general vision, vision specific mental health, color vision, and driving were modestly correlated; visual pain was weakly correlated; and two were not significantly correlated. Correcting for visual actuity weakened the strength of the correlation coefficients. CONCLUSIONS: The SF-36 is unlikely to be useful in determining visual impairment in patients with glaucoma. Based on the moderate correlation between visual field impairment and the VF-14 score, this questionnaire may be generalizable to patients with glaucoma. Several of the NEI-VFQ scales correlate with visual field impairment scores in patients with a wide range of glaucomatous damage. PMID:8981717

  3. Use of images in shelf life assessment of fruit salad.

    PubMed

    Manzocco, Lara; Rumignani, Alberto; Lagazio, Corrado

    2012-07-01

    Fruit salads stored for different lengths of time as well as their images were used to estimate sensory shelf life by survival analysis. Shelf life estimates obtained using fruit salad images were longer than those achieved by analyzing the real product. This was attributed to the fact that images are 2-dimensional representations of real food, probably not comprehensive of all the visual information needed by the panelists to produce an acceptability/unacceptability judgment. Images were also subjected to image analysis and the analysis of the overall visual quality by a trained panel. These indices proved to be highly correlated to consumer rejection of the fruit salad and could be exploited for routine shelf life assessment of analogous products. To this regard, a failure criterion of 25% consumer rejection could be equivalent to a score 3 in a 5-point overall visual quality scale. Food images can be used to assess product shelf life. In the case of fruit salads, the overall visual quality assessed by a trained panel on product images and the percentage of brown pixels in digital images can be exploited to estimate shelf life corresponding to a selected consumer rejection. © 2012 Institute of Food Technologists®

  4. A Regression-Based Family of Measures for Full-Reference Image Quality Assessment

    NASA Astrophysics Data System (ADS)

    Oszust, Mariusz

    2016-12-01

    The advances in the development of imaging devices resulted in the need of an automatic quality evaluation of displayed visual content in a way that is consistent with human visual perception. In this paper, an approach to full-reference image quality assessment (IQA) is proposed, in which several IQA measures, representing different approaches to modelling human visual perception, are efficiently combined in order to produce objective quality evaluation of examined images, which is highly correlated with evaluation provided by human subjects. In the paper, an optimisation problem of selection of several IQA measures for creating a regression-based IQA hybrid measure, or a multimeasure, is defined and solved using a genetic algorithm. Experimental evaluation on four largest IQA benchmarks reveals that the multimeasures obtained using the proposed approach outperform state-of-the-art full-reference IQA techniques, including other recently developed fusion approaches.

  5. Quality of Vision in Eyes With Epiphora Undergoing Lacrimal Passage Intubation.

    PubMed

    Koh, Shizuka; Inoue, Yasushi; Ochi, Shintaro; Takai, Yoshihiro; Maeda, Naoyuki; Nishida, Kohji

    2017-09-01

    To investigate visual function and optical quality in eyes with epiphora undergoing lacrimal passage intubation. Prospective case series. Thirty-four eyes of 30 patients with lacrimal passage obstruction were enrolled. Before and 1 month after lacrimal passage intubation, functional visual acuity (FVA), higher-order aberrations (HOAs), lower tear meniscus, and tear clearance were assessed. An FVA measurement system was used to examine changes in continuous visual acuity (VA) over time, and visual function parameters such as FVA, visual maintenance ratio, and blink frequency were obtained. Sequential ocular HOAs were measured for 10 seconds after the blink using a wavefront sensor. Aberration data were analyzed in the central 4 mm for coma-like, spherical-like, and total HOAs. Fluctuation and stability indices of the total HOAs over time were calculated. Lower tear meniscus was assessed by anterior segment optical coherence tomography. After lacrimal passage intubation, visual function significantly improved, as indicated by improved FVA (P = .003) and visual maintenance ratio (P < .001). Blink frequency decreased significantly after treatment (P = .01). Optical quality significantly improved, as indicated by a decrease in coma-like aberrations (P = .003), spherical-like aberrations (P = .018), and total HOAs (P = .001). Stability index increased (P < .001) and fluctuation index decreased (P = .019), and tear meniscus dimension decreased (P < .001). Lacrimal passage intubation for eyes with epiphora significantly improved visual function and optical quality via patency of the lacrimal passage. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Backward Registration Based Aspect Ratio Similarity (ARS) for Image Retargeting Quality Assessment.

    PubMed

    Zhang, Yabin; Fang, Yuming; Lin, Weisi; Zhang, Xinfeng; Li, Leida

    2016-06-28

    During the past few years, there have been various kinds of content-aware image retargeting operators proposed for image resizing. However, the lack of effective objective retargeting quality assessment metrics limits the further development of image retargeting techniques. Different from traditional Image Quality Assessment (IQA) metrics, the quality degradation during image retargeting is caused by artificial retargeting modifications, and the difficulty for Image Retargeting Quality Assessment (IRQA) lies in the alternation of the image resolution and content, which makes it impossible to directly evaluate the quality degradation like traditional IQA. In this paper, we interpret the image retargeting in a unified framework of resampling grid generation and forward resampling. We show that the geometric change estimation is an efficient way to clarify the relationship between the images. We formulate the geometric change estimation as a Backward Registration problem with Markov Random Field (MRF) and provide an effective solution. The geometric change aims to provide the evidence about how the original image is resized into the target image. Under the guidance of the geometric change, we develop a novel Aspect Ratio Similarity metric (ARS) to evaluate the visual quality of retargeted images by exploiting the local block changes with a visual importance pooling strategy. Experimental results on the publicly available MIT RetargetMe and CUHK datasets demonstrate that the proposed ARS can predict more accurate visual quality of retargeted images compared with state-of-the-art IRQA metrics.

  7. Weighted-MSE based on saliency map for assessing video quality of H.264 video streams

    NASA Astrophysics Data System (ADS)

    Boujut, H.; Benois-Pineau, J.; Hadar, O.; Ahmed, T.; Bonnet, P.

    2011-01-01

    Human vision system is very complex and has been studied for many years specifically for purposes of efficient encoding of visual, e.g. video content from digital TV. There have been physiological and psychological evidences which indicate that viewers do not pay equal attention to all exposed visual information, but only focus on certain areas known as focus of attention (FOA) or saliency regions. In this work, we propose a novel based objective quality assessment metric, for assessing the perceptual quality of decoded video sequences affected by transmission errors and packed loses. The proposed method weights the Mean Square Error (MSE), Weighted-MSE (WMSE), according to the calculated saliency map at each pixel. Our method was validated trough subjective quality experiments.

  8. PERSPECTIVE: Is acuity enough? Other considerations in clinical investigations of visual prostheses

    NASA Astrophysics Data System (ADS)

    Lepri, Bernard P.

    2009-06-01

    Visual impairing eye diseases are the major frontier facing ophthalmic research today in light of our rapidly aging population. The visual skills necessary for improving the quality of daily function and life are inextricably linked to these impairing diseases. Both research and reimbursement programs are emphasizing outcome-based results. Is improvement in visual acuity alone enough to improve the function and quality of life of visually impaired persons? This perspective summarizes the types of effectiveness endpoints for clinical investigations of visual prostheses that go beyond visual acuity. The clinical investigation of visual prostheses should include visual function, functional vision and quality of life measures. Specifically, they encompass contrast sensitivity, orientation and mobility, activities of daily living and quality of life assessments. The perspective focuses on the design of clinical trials for visual prostheses and the methods of determining effectiveness above and beyond visual acuity that will yield outcomes that are measured by improved function in the visual world and quality of life. The visually impaired population is the primary consideration in this presentation with particular emphases on retinitis pigmentosa and age-related macular degeneration. Clinical trials for visual prostheses cannot be isolated from the need for medical rehabilitation in order to obtain measurements of effectiveness that produce outcomes/evidence-based success. This approach will facilitate improvement in daily function and quality of life of patients with diseases that cause chronic vision impairment. The views and opinions are those of the author and do not necessarily reflect those of the US Food and Drug Administration, the US Department of Health and Human Services or the Public Health Service.

  9. Association between Visual Impairment and Low Vision and Sleep Duration and Quality among Older Adults in South Africa.

    PubMed

    Peltzer, Karl; Phaswana-Mafuya, Nancy

    2017-07-19

    This study aims to estimate the association between visual impairment and low vision and sleep duration and poor sleep quality in a national sample of older adults in South Africa. A national population-based cross-sectional Study of Global Ageing and Adults Health (SAGE) wave 1 was conducted in 2008 with a sample of 3840 individuals aged 50 years or older in South Africa. The interviewer-administered questionnaire assessed socio-demographic characteristics, health variables, sleep duration, quality, visual impairment, and vision. Results indicate that 10.0% of the sample reported short sleep duration (≤5 h), 46.6% long sleep (≥9 h), 9.3% poor sleep quality, 8.4% self-reported and visual impairment (near and/or far vision); and 43.2% measured low vision (near and/or far vision) (0.01-0.25 decimal) and 7.5% low vision (0.01-0.125 decimal). In fully adjusted logistic regression models, self-reported visual impairment was associated with short sleep duration and poor sleep quality, separately and together. Low vision was only associated with long sleep duration and poor sleep quality in unadjusted models. Self-reported visual impairment was related to both short sleep duration and poor sleep quality. Population data on sleep patterns may want to include visual impairment measures.

  10. Information theoretical assessment of visual communication with wavelet coding

    NASA Astrophysics Data System (ADS)

    Rahman, Zia-ur

    1995-06-01

    A visual communication channel can be characterized by the efficiency with which it conveys information, and the quality of the images restored from the transmitted data. Efficient data representation requires the use of constraints of the visual communication channel. Our information theoretic analysis combines the design of the wavelet compression algorithm with the design of the visual communication channel. Shannon's communication theory, Wiener's restoration filter, and the critical design factors of image gathering and display are combined to provide metrics for measuring the efficiency of data transmission, and for quantitatively assessing the visual quality of the restored image. These metrics are: a) the mutual information (Eta) between the radiance the radiance field and the restored image, and b) the efficiency of the channel which can be roughly measured by as the ratio (Eta) /H, where H is the average number of bits being used to transmit the data. Huck, et al. (Journal of Visual Communication and Image Representation, Vol. 4, No. 2, 1993) have shown that channels desinged to maximize (Eta) , also maximize. Our assessment provides a framework for designing channels which provide the highest possible visual quality for a given amount of data under the critical design limitations of the image gathering and display devices. Results show that a trade-off exists between the maximum realizable information of the channel and its efficiency: an increase in one leads to a decrease in the other. The final selection of which of these quantities to maximize is, of course, application dependent.

  11. Visualizing surgical quality data with treemaps.

    PubMed

    Hugine, Akilah L; Guerlain, Stephanie A; Turrentine, Florence E

    2014-09-01

    Treemaps are space-constrained visualizations for displaying hierarchical data structures using nested rectangles. The visualization allows large amounts of data to be examined in one display. The objective of this research was to examine the effects of using treemap visualizations to help surgeons assess surgical quality data from the American College of Surgeons created the National Surgical Quality Improvement Program database in a quick and timely manner. A controlled human subjects experiment was conducted to assess the ability of individuals to make quick and accurate judgments on surgery data by visualizing a treemap, with data hierarchically displayed by surgeon group, surgeon, and patient. Participants were given 20 task questions to complete involving examining the treemap and comparing surgeons' patients based on outcomes (dead or alive) and length of stay days. The outcomes measured were error (incorrect or correct) and task completion time. 120 participants completed 20 task questions for a total of 2400 responses. The main effects of layout and node size were found to be significant for absolute error, P < 0.0505 and P < 0.0185, respectively. The average judgment time to complete a task was 24 s with an accuracy rate of approximately 68%. This study served as a proof of concept to determine if treemaps could be beneficial in assessing surgical data retrospectively by allowing surgeons and healthcare administrators to make quick visual judgments. The study found that factors about the layout design affect judgment performance. Future research is needed to examine whether implementing the treemap within a dashboard system will improve on judgment accuracy for surgical quality questions. Published by Elsevier Inc.

  12. Parts-based stereoscopic image assessment by learning binocular manifold color visual properties

    NASA Astrophysics Data System (ADS)

    Xu, Haiyong; Yu, Mei; Luo, Ting; Zhang, Yun; Jiang, Gangyi

    2016-11-01

    Existing stereoscopic image quality assessment (SIQA) methods are mostly based on the luminance information, in which color information is not sufficiently considered. Actually, color is part of the important factors that affect human visual perception, and nonnegative matrix factorization (NMF) and manifold learning are in line with human visual perception. We propose an SIQA method based on learning binocular manifold color visual properties. To be more specific, in the training phase, a feature detector is created based on NMF with manifold regularization by considering color information, which not only allows parts-based manifold representation of an image, but also manifests localized color visual properties. In the quality estimation phase, visually important regions are selected by considering different human visual attention, and feature vectors are extracted by using the feature detector. Then the feature similarity index is calculated and the parts-based manifold color feature energy (PMCFE) for each view is defined based on the color feature vectors. The final quality score is obtained by considering a binocular combination based on PMCFE. The experimental results on LIVE I and LIVE Π 3-D IQA databases demonstrate that the proposed method can achieve much higher consistency with subjective evaluations than the state-of-the-art SIQA methods.

  13. Visual disability and quality of life in glaucoma patients.

    PubMed

    Cesareo, Massimo; Ciuffoletti, Elena; Ricci, Federico; Missiroli, Filippo; Giuliano, Mario Alberto; Mancino, Raffaele; Nucci, Carlo

    2015-01-01

    Glaucoma is an optic neuropathy that can result in progressive and irreversible vision loss, thereby affecting quality of life (QoL) of patients. Several studies have shown a strong correlation between visual field damage and visual disability in patients with glaucoma, even in the early stages of the disease. Visual impairment due to glaucoma affects normal daily activities required for independent living, such as driving, walking, and reading. There is no generally accepted instrument for assessing quality of life in glaucoma patients; different factors involved in visual disability from the disease are difficult to quantify and not easily standardized. This chapter summarizes recent works from clinical and epidemiological studies, which describe how glaucoma affects the performance of important vision-related activities and QoL. © 2015 Elsevier B.V. All rights reserved.

  14. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    PubMed

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  15. Visual functioning and quality of life among the older people in Hong Kong.

    PubMed

    Leung, Jason C S; Kwok, Timothy C Y; Chan, Dicken C C; Yuen, Kay W K; Kwok, Anthony W L; Choy, Dicky T K; Lau, Edith M C; Leung, P C

    2012-08-01

    This study aimed to examine the association of visual functioning and health-related quality of life (HRQOL) among the older community in Hong Kong. This study used the baseline examination of a cohort study MrOs and MsOs (a large study for osteoporosis in men and women). This study was set in the Hong Kong community. A total of 4000 ambulatory community-dwelling Chinese men and women aged 65 years or above participated in this study. Health-related quality of life was assessed by Medical Outcomes Study Short Form-12 (SF-12), with physical component summary (PCS) and mental component summary (MCS) scores. Demographics, medical history, mental status, and quality of life were obtained from face-to-face interviews, using standard structured questionnaire. Visual functions (i.e., binocular visual acuity, contrast sensitivity, and stereopsis) were assessed by different visual tests after refraction corrections. Different visual functions were tested simultaneously in multiple ordinal logistic regression models. Better binocular visual acuity, contrast sensitivity, and stereopsis were associated with higher PCS. Visual acuity and contrast sensitivity was associated with PCS after adjustment of different visual functions and sex, age, education level, cognitive status, and history of diabetes in multivariate analysis, (OR = 0.73, 95% CI = 0.54 0.98) for low vision (≤6/24) compared with ≥6/9 in visual acuity and (OR = 1.34, 95% CI = 1.09 1.64) for contrast sensitivity row b 5-8 (best) compared with 0-1 (worst). MCS was only associated with visual acuity and contrast sensitivity, but no association was found after adjustment. Apparent association was found between visual functions and HRQOL among older community in Hong Kong. In addition to visual acuity, contrast sensitivity is also important, so eye care should also cover. Copyright © 2011 John Wiley & Sons, Ltd.

  16. On the performance of metrics to predict quality in point cloud representations

    NASA Astrophysics Data System (ADS)

    Alexiou, Evangelos; Ebrahimi, Touradj

    2017-09-01

    Point clouds are a promising alternative for immersive representation of visual contents. Recently, an increased interest has been observed in the acquisition, processing and rendering of this modality. Although subjective and objective evaluations are critical in order to assess the visual quality of media content, they still remain open problems for point cloud representation. In this paper we focus our efforts on subjective quality assessment of point cloud geometry, subject to typical types of impairments such as noise corruption and compression-like distortions. In particular, we propose a subjective methodology that is closer to real-life scenarios of point cloud visualization. The performance of the state-of-the-art objective metrics is assessed by considering the subjective scores as the ground truth. Moreover, we investigate the impact of adopting different test methodologies by comparing them. Advantages and drawbacks of every approach are reported, based on statistical analysis. The results and conclusions of this work provide useful insights that could be considered in future experimentation.

  17. Changes in Quality of Life in Visually Impaired Patients after Low-Vision Rehabilitation

    ERIC Educational Resources Information Center

    Renieri, Giulia; Pitz, Susanne; Pfeiffer, Norbert; Beutel, Manfred E.; Zwerenz, Rudiger

    2013-01-01

    The objective of the study was to assess the impact of low-vision aids on quality of life. Interviews included a modified version of the National Eye Institute Visual Functioning Questionnaire (Modified German NEI VFQ-25), the Hospital Anxiety and Depression Scale, the Mini-Mental State Examination Blind, and Indicators of the Rehabilitation…

  18. Associations among visual acuity and vision- and health-related quality of life among patients in the multicenter uveitis steroid treatment trial.

    PubMed

    Frick, Kevin D; Drye, Lea T; Kempen, John H; Dunn, James P; Holland, Gary N; Latkany, Paul; Rao, Narsing A; Sen, H Nida; Sugar, Elizabeth A; Thorne, Jennifer E; Wang, Robert C; Holbrook, Janet T

    2012-03-01

    To evaluate the associations between visual acuity and self-reported visual function; visual acuity and health-related quality of life (QoL) metrics; a summary measure of self-reported visual function and health-related QoL; and individual domains of self-reported visual function and health-related QoL in patients with uveitis. Best-corrected visual acuity, vision-related functioning as assessed by the NEI VFQ-25, and health-related QoL as assessed by the SF-36 and EuroQoL EQ-5D questionnaires were obtained at enrollment in a clinical trial of uveitis treatments. Multivariate regression and Spearman correlations were used to evaluate associations between visual acuity, vision-related function, and health-related QoL. Among the 255 patients, median visual acuity in the better-seeing eyes was 20/25, the vision-related function score indicated impairment (median, 60), and health-related QoL scores were within the normal population range. Better visual acuity was predictive of higher visual function scores (P ≤ 0.001), a higher SF-36 physical component score, and a higher EQ-5D health utility score (P < 0.001). The vision-specific function score was predictive of all general health-related QoL (P < 0.001). The correlations between visual function score and general quality of life measures were moderate (ρ = 0.29-0.52). The vision-related function score correlated positively with visual acuity and moderately positively with general QoL measures. Cost-utility analyses relying on changes in generic healthy utility measures will be more likely to detect changes when there are clinically meaningful changes in vision-related function, rather than when there are only changes in visual acuity. (ClinicalTrials.gov number, NCT00132691.).

  19. Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment

    PubMed Central

    2012-01-01

    Background The short inversion time inversion recovery (STIR) black-blood technique has been used to visualize myocardial edema, and thus to differentiate acute from chronic myocardial lesions. However, some cardiovascular magnetic resonance (CMR) groups have reported variable image quality, and hence the diagnostic value of STIR in routine clinical practice has been put into question. The aim of our study was to analyze image quality and diagnostic performance of STIR using a set of pulse sequence parameters dedicated to edema detection, and to discuss possible factors that influence image quality. We hypothesized that STIR imaging is an accurate and robust way of detecting myocardial edema in non-selected patients with acute myocardial infarction. Methods Forty-six consecutive patients with acute myocardial infarction underwent CMR (day 4.5, +/- 1.6) including STIR for the assessment of myocardial edema and late gadolinium enhancement (LGE) for quantification of myocardial necrosis. Thirty of these patients underwent a follow-up CMR at approximately six months (195 +/- 39 days). Both STIR and LGE images were evaluated separately on a segmental basis for image quality as well as for presence and extent of myocardial hyper-intensity, with both visual and semi-quantitative (threshold-based) analysis. LGE was used as a reference standard for localization and extent of myocardial necrosis (acute) or scar (chronic). Results Image quality of STIR images was rated as diagnostic in 99.5% of cases. At the acute stage, the sensitivity and specificity of STIR to detect infarcted segments on visual assessment was 95% and 78% respectively, and on semi-quantitative assessment was 99% and 83%, respectively. STIR differentiated acutely from chronically infarcted segments with a sensitivity of 95% by both methods and with a specificity of 99% by visual assessment and 97% by semi-quantitative assessment. The extent of hyper-intense areas on acute STIR images was 85% larger than those on LGE images, with a larger myocardial salvage index in reperfused than in non-reperfused infarcts (p = 0.035). Conclusions STIR with appropriate pulse sequence settings is accurate in detecting acute myocardial infarction (MI) and distinguishing acute from chronic MI with both visual and semi-quantitative analysis. Due to its unique technical characteristics, STIR should be regarded as an edema-weighted rather than a purely T2-weighted technique. PMID:22455461

  20. Facial markings in the social cuckoo wasp Polistes sulcifer: No support for the visual deception and the assessment hypotheses.

    PubMed

    Cini, Alessandro; Ortolani, Irene; Zechini, Luigi; Cervo, Rita

    2015-02-01

    Insect social parasites have to conquer a host colony by overcoming its defensive barriers. In addition to increased fighting abilities, many social parasites evolved sophisticated sensory deception mechanisms to elude host colonies defenses by exploiting host communication channels. Recently, it has been shown that the conspicuous facial markings of a paper wasp social parasite, Polistes sulcifer, decrease the aggressiveness of host foundresses. Two main hypotheses stand as explanations of this phenomenon: visual sensory deception (i.e. the black patterning reduces host aggression by exploiting the host visual communication system) and visual quality assessment (i.e. facial markings reduce aggressiveness as they signal the increased fighting ability of parasites). Through behavioral assays and morphological measurements we tested three predictions resulting from these hypotheses and found no support either for the visual sensory deception or for the quality assessment to explain the reduction in host aggressiveness towards the parasite. Our results suggest that other discrimination processes may explain the observed phenomenon. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. [Quality of life - methodology and clinical practice aspects with a focus on ocular medicine].

    PubMed

    Franke, G H; Gall, C

    2008-08-01

    Due to the demographic development in western industrialised countries, the proportion of visually impaired persons is likely to increase in the future. Currently there is a shift in scientific recognition from relative neglect of psychopathological distress in the visually impaired to better notice of disease-related subjective impairments that are detectable with specific questionnaire measures. Visual acuity primarily determines the subjective rating of visual functioning independent from the eye disease. Ophthalmic patients who show only mild symptoms from a medical point of view normally suffer considerably diminished vision-related quality of life with respect to physical, functional, mental, and social aspects. Treatment effects have been shown using vision-related quality-of-life measures for different ophthalmic diseases, particularly cataract surgery. Assessment of vision-related quality of life provides a meaningful complement to objective data.

  2. Nutritional assessment and diet quality of visually impaired Spanish children.

    PubMed

    Montero, Pilar

    2005-01-01

    The visually impaired represents a fairly numerous group in Spain although no data on their nutritional status has previously been published. This work aims to assess the nutritional state of a sample of visually impaired children and the quality of their diet. The sample comprised 229 boys and girls aged between 8 and 18 years (mean = 14, SD = 2.6), all of whom had a visual discapacity and were students of the Centros de Recursos Educativos (CREs; Educational Resources Centres) of the Organización Nacional de Ciegos de España (ONCE; Spanish National Organization for the Blind). This sample featured a high prevalence of overweight (25.8%) and obesity (11.8%) according to the international standard. The mean daily energy consumption and the quantity of carbohydrates, fats, proteins and fibre were greater in boys (2604 kcal day(-1); 290 g of carbohydrates, 126 g of fats and 90 g of proteins) than in girls (2159 kcal day(-1), 232 g of carbohydrates, 107 g of fats and 80 g of proteins). No differences in diet intake according to degree of visual impairment were found. Their diet was unbalanced in comparison with the nutritional objectives for the Spanish population, since consumption of carbohydrates was low and that of fats was very high. The results relating to the quality of the diet reveal quite large deviations from the Mediterranean model. Only 11.9% of the whole sample had a value corresponding to a good quality diet. The pattern of dietary consumption was the same as that observed in non visually impaired children in Spain in quantity and quality, nevertheless the prevalence of overweight and obesity is higher than in children without visual handicaps.

  3. The Association Between Visual Assessment of Quality of Movement and Three-Dimensional Analysis of Pelvis, Hip, and Knee Kinematics During a Lateral Step Down Test.

    PubMed

    Rabin, Alon; Portnoy, Sigal; Kozol, Zvi

    2016-11-01

    Rabin, A, Portnoy, S, and Kozol, Z. The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test. J Strength Cond Res 30(11): 3204-3211, 2016-Altered movement patterns including contralateral pelvic drop, increased hip adduction, knee abduction, and external rotation have been previously implicated in several lower extremity pathologies. Although various methods exist for assessing movement patterns, real-time visual observation is the most readily available method. The purpose of this study was to determine whether differing visual ratings of trunk, pelvis, and knee alignment, as well as overall quality of movement, are associated with differences in 3-dimensional trunk, pelvis, hip, or knee kinematics during a lateral step down test. Trunk, pelvis, and knee alignment of 30 healthy participants performing the lateral step down were visually rated as "good" or "faulty" based on previously established criteria. An additional categorization of overall quality of movement as either good or moderate was performed based on the aggregate score of each individual rating criterion. Three-dimensional motion analysis of trunk, pelvis, hip, and knee kinematics was simultaneously performed. A faulty pelvis alignment displayed a greater peak contralateral pelvic drop (effect size [ES], 1.65; p < 0.01) and a greater peak hip adduction (ES: 1.04, p = 0.01) compared with participants with a good pelvis alignment. Participants with a faulty knee alignment displayed greater peak knee external rotation compared with participants with a good knee alignment (ES, 0.78; p = 0.02). Participants with an overall moderate quality of movement displayed increased peak contralateral pelvic drop (ES, 1.07; p = 0.01) and peak knee external rotation (ES, 0.72; p = 0.04) compared with those with an overall good quality of movement. Visual rating of quality of movement during a lateral step down test, as performed by an experienced physical therapist, is associated with differences in several kinematics previously implicated in various pathologies.

  4. Accuracy, reliability, and timing of visual evaluations of decay in fresh-cut lettuce

    USDA-ARS?s Scientific Manuscript database

    Visual assessments are used for evaluating the quality of food products, such as fresh-cut lettuce packaged in bags with modified atmosphere. We have compared the accuracy and the reliability of visual evaluations of decay on fresh-cut lettuce performed with experienced and inexperienced raters. In ...

  5. Screening methods for post-stroke visual impairment: a systematic review.

    PubMed

    Hanna, Kerry Louise; Hepworth, Lauren Rachel; Rowe, Fiona

    2017-12-01

    To provide a systematic overview of the various tools available to screen for post-stroke visual impairment. A review of the literature was conducted including randomised controlled trials, controlled trials, cohort studies, observational studies, systematic reviews and retrospective medical note reviews. All languages were included and translation was obtained. Participants included adults ≥18 years old diagnosed with a visual impairment as a direct cause of a stroke. We searched a broad range of scholarly online resources and hand-searched articles registers of published, unpublished and on-going trials. Search terms included a variety of MESH terms and alternatives in relation to stroke and visual conditions. Study selection was performed by two authors independently. The quality of the evidence and risk of bias were assessed using the STROBE, GRACE and PRISMA statements. A total of 25 articles (n = 2924) were included in this review. Articles appraised reported on tools screening solely for visual impairments or for general post-stroke disabilities inclusive of vision. The majority of identified tools screen for visual perception including visual neglect (VN), with few screening for visual acuity (VA), visual field (VF) loss or ocular motility (OM) defects. Six articles reported on nine screening tools which combined visual screening assessment alongside screening for general stroke disabilities. Of these, three included screening for VA; three screened for VF loss; three screened for OM defects and all screened for VN. Two tools screened for all visual impairments. A further 19 articles were found which reported on individual vision screening tests in stroke populations; two for VF loss; 11 for VN and six for other visual perceptual defects. Most tools cannot accurately account for those with aphasia or communicative deficits, which are common problems following a stroke. There is currently no standardised visual screening tool which can accurately assess all potential post-stroke visual impairments. The current tools screen for only a number of potential stroke-related impairments, which means many visual defects may be missed. The sensitivity of those which screen for all impairments is significantly lowered when patients are unable to report their visual symptoms. Future research is required to develop a tool capable of assessing stroke patients which encompasses all potential visual deficits and can also be easily performed by both the patients and administered by health care professionals in order to ensure all stroke survivors with visual impairment are accurately identified and managed. Implications for Rehabilitation Over 65% of stroke survivors will suffer from a visual impairment, whereas 45% of stroke units do not assess vision. Visual impairment significantly reduces the quality of life, such as being unable to return to work, driving and depression. This review outlines the available screening methods to accurately identify stroke survivors with visual impairments. Identifying visual impairment after stroke can aid general rehabilitation and thus, improve the quality of life for these patients.

  6. Towards A Complete Model Of Photopic Visual Threshold Performance

    NASA Astrophysics Data System (ADS)

    Overington, I.

    1982-02-01

    Based on a wide variety of fragmentary evidence taken from psycho-physics, neurophysiology and electron microscopy, it has been possible to put together a very widely applicable conceptual model of photopic visual threshold performance. Such a model is so complex that a single comprehensive mathematical version is excessively cumbersome. It is, however, possible to set up a suite of related mathematical models, each of limited application but strictly known envelope of usage. Such models may be used for assessment of a variety of facets of visual performance when using display imagery, including effects and interactions of image quality, random and discrete display noise, viewing distance, image motion, etc., both for foveal interrogation tasks and for visual search tasks. The specific model may be selected from the suite according to the assessment task in hand. The paper discusses in some depth the major facets of preperceptual visual processing and their interaction with instrumental image quality and noise. It then highlights the statistical nature of visual performance before going on to consider a number of specific mathematical models of partial visual function. Where appropriate, these are compared with widely popular empirical models of visual function.

  7. The effectiveness of VIPP-V parenting training for parents of young children with a visual or visual-and-intellectual disability: study protocol of a multicenter randomized controlled trial.

    PubMed

    Overbeek, Mathilde M; Sterkenburg, Paula S; Kef, Sabina; Schuengel, Carlo

    2015-09-09

    Visual or visual-and-intellectual disabilities of children make daily interactions more difficult for their parents and may impact the quality of the parent-child relationship. To support these parents, an existing intervention (Video-feedback Intervention to promote Positive Parenting; VIPP; Juffer F, Bakermans-Kranenburg MJ, van IJzendoorn MH, 2008. Promoting positive parenting; an attachment-based intervention. Mahwah, NJ: Lawrence Erlbaum Associates; 2008) was adapted for use with parents of children with a visual or visual-and-intellectual disability (VIPP-V). This attachment-based intervention was hypothesized to support parents' interpretation and understanding of the behavior of their child with a visual or visual-and-intellectual disability and respond to their child's signals in a sensitive way to improve parent-child interaction quality. A randomized controlled trial (RCT) will be conducted to assess the effectiveness of the adapted intervention VIPP-V (Video-feedback Intervention to promote Positive Parenting in parents of children with Visual or visual-and-intellectual disabilities). Parent-child dyads will be randomized into two groups: 50 dyads will receive VIPP-V in combination with care-as-usual and 50 dyads will receive care-as-usual. Families with a child (1-5 years of age) with a visual or visual-and-intellectual disability will be recruited for participation in the study. Primary outcome measures are parental sensitivity and the quality of parent-child interaction. Secondary outcome measures are parental self-efficacy, and parenting stress. To assess feasibility of implementation of the intervention the experiences of early intervention workers with regard to using VIPP-V are assessed. Moderator variables are the child's developmental age, working alliance between parent and VIPP-V intervention worker and empathy of the VIPP-V intervention worker. Data will be collected approximately one week before the intervention starts (T1), one week (T2) and three months (T3) after the intervention. Parent-child dyads in the care-as-usual-only condition will be assessed at the same time points. Both intention-to-treat and completer analyses will be performed. Descriptive findings in pilot cases suggest benefits from VIPP-V, and compatibility with existing services for parents of children with a visual or visual-and-intellectual disability. The current study will provide insight into the effectiveness of this intervention for parents of children with a visual or visual-and-intellectual disability, and, if the intervention is effective, prepare the field for broad-scale implementation. Nederlands Trial Register NTR4306 (registered 5 December 2013).

  8. Assessing public concern for landscape quality: a potential model to identify visual thresholds

    Treesearch

    Arthur W. Magill

    1990-01-01

    Considerable public criticism and sometimes legal obstructions have been directed toward landscape management in relation to the extraction of natural resources. Many managers do not understand public concerns for visually attractive resources. Managers need to know when landscape alterations, like clearcuts, attract public attention and become visually objectionable....

  9. Vision-Related Quality of Life in Patients with Ocular Graft-versus-host Disease

    PubMed Central

    Saboo, Ujwala S; Amparo, Francisco; Abud, Tulio B; Schaumberg, Debra A; Dana, Reza

    2015-01-01

    Objective To assess the vision-related quality of life in a cohort of patients with ocular graft-versus-host disease (GVHD). Design Prospective study. Participants Eighty-four patients diagnosed with chronic ocular GVHD Methods We assessed the vision-related quality of life with the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). The symptoms of ocular GVHD were assessed using the Ocular Surface Disease Index (OSDI) and Symptom Assessment in Dry Eye (SANDE) questionnaires. Main outcome measures We assessed vision-related quality of life with NEI-VFQ-25 and compared the scores obtained from patients with ocular GVHD to those from a healthy population. In the ocular GVHD population, we also evaluated the associations between the NEI-VFQ-25 and dry eye symptoms measured by OSDI and SANDE questionnaires, age, duration of disease, best-corrected visual acuity, corneal fluorescein staining, tear break-up time, and Schirmer test. Results The mean composite NEI-VFQ-25 score in patients with ocular GVHD was 76.5 ± 17. Compared to healthy subjects, ocular GVHD patients reported reduced scores on all NEI-VFQ-25 subscales (each P < 0.001) with exception of color vision (P = 0.11). The NEI-VFQ-25 composite scores significantly correlated with OSDI (R = −0.81, P < 0.001), SANDE (R = −0.56, P < 0.001), corneal fluorescein staining (R = −0.36, P = 0.001) and best-corrected visual acuity (R = −0.30, P = 0.004). Conclusion Patients with ocular GVHD experience measurable impairment of vision-related quality of life. This study highlights the impact of ocular GVHD on the vision-related quality of life, and hence the importance of comprehensive diagnosis and treatment of this condition. PMID:26001816

  10. Assessing the Quality of Expertise Differences in the Comprehension of Medical Visualizations

    ERIC Educational Resources Information Center

    Gegenfurtner, Andreas; Siewiorek, Anna; Lehtinen, Erno; Saljo, Roger

    2013-01-01

    Understanding how best to assess expertise, the situational variations of expertise, and distinctive qualities of expertise that arises from particular workplace experiences, presents an important challenge. Certainly, at this time, there is much interest in identifying standard occupational measures and competences, which are not well aligned…

  11. Frequency and Correlates of Distant Visual Impairment in Patients with Schizophrenia, Bipolar Disorder, and Major Depressive Disorder.

    PubMed

    Zheng, W; Tang, L R; Correll, C U; Ungvari, G S; Chiu, H F K; Xiang, Y Q; Xiang, Y T

    2015-09-01

    Distant visual impairment in the severely mentally ill is under-researched. This study aimed to assess the frequency and correlates of distant visual impairment in a cohort of Chinese psychiatric patients, including its effect on their quality of life. Adult psychiatric inpatients with schizophrenia, bipolar disorder, and major depressive disorder consecutively admitted to a psychiatric hospital in Beijing, China underwent assessments of psychopathology (Brief Psychiatric Rating Scale, 16-item Quick Inventory of Depressive Symptomatology [Self-Report]), quality of life (12-item Short-Form Medical Outcomes Study [SF-12], 25-item National Eye Institute Visual Function Questionnaire [NEI-VFQ25]), adverse effects (Udvalg for Kliniske Undersøgelser Side Effect Rating Scale), and presenting (as opposed to uncorrected) distant visual acuity (Logarithm of the Minimum Angle of Resolution [LogMAR] chart with patients wearing spectacles, if they owned them). Distant visual impairment was defined as binocular distant visual acuity of a LogMAR score of ≥ 0.5 (< 6/18 Snellen acuity). Among 356 patients who met the study criteria, the frequency of distant visual impairment was 12.6% (15.2% with schizophrenia, 11.9% with bipolar disorder, 8.8% with major depressive disorder). In multiple logistic regression analysis, distant visual impairment was significantly associated with ocular disease only (p = 0.002, odds ratio = 3.2, 95% confidence interval = 1.5-6.7). Controlling for the confounding effect of ocular disease, patients with distant visual impairment had a lower quality of life in the general vision domain of the NEI-VFQ25 (F[2, 353] = 9.5, p = 0.002) compared with those without. No differences in the physical and mental domains of the SF-12 and in other domains of the NEI-VFQ25 were noted in these 2 groups. One-eighth of middle-aged severely mentally ill patients had distant visual impairment. Considering the impact of distant visual impairment on daily functioning, severely mentally ill patients need to be screened for impaired eyesight as part of their comprehensive health assessment.

  12. The adenosine triphosphate method as a quality control tool to assess 'cleanliness' of frequently touched hospital surfaces.

    PubMed

    Knape, L; Hambraeus, A; Lytsy, B

    2015-10-01

    The adenosine triphosphate (ATP) method is widely accepted as a quality control method to complement visual assessment, in the specifications of requirements, when purchasing cleaning contractors in Swedish hospitals. To examine whether the amount of biological load, as measured by ATP on frequently touched near-patient surfaces, had been reduced after an intervention; to evaluate the correlation between visual assessment and ATP levels on the same surfaces; to identify aspects of the performance of the ATP method as a tool in evaluating hospital cleanliness. A prospective intervention study in three phases was carried out in a medical ward and an intensive care unit (ICU) at a regional hospital in mid-Sweden between 2012 and 2013. Existing cleaning procedures were defined and baseline tests were sampled by visual inspection and ATP measurements of ten frequently touched surfaces in patients' rooms before and after intervention. The intervention consisted of educating nursing staff about the importance of hospital cleaning and direct feedback of ATP levels before and after cleaning. The mixed model showed a significant decrease in ATP levels after the intervention (P < 0.001). Relative light unit values were lower in the ICU. Cleanliness as judged by visual assessments improved. In the logistic regression analysis, there was a significant association between visual assessments and ATP levels. Direct feedback of ATP levels, together with education and introduction of written cleaning protocols, were effective tools to improve cleanliness. Visual assessment correlated with the level of ATP but the correlation was not absolute. The ATP method could serve as an educational tool for staff, but is not enough to assess hospital cleanliness in general as only a limited part of a large area is covered. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Investigating the quality of expectorated sputum for tuberculosis diagnosis in Bolivia.

    PubMed

    Hernández, P; Punchak, M; Camacho, M; Hepple, P; McNerney, R

    2015-09-01

    A low-power microscope-based cytological system to assess the quality of expectorated sputum provided for tuberculosis (TB) diagnosis was piloted in Bolivia. A total of 3688 samples were subjected to visual and cytological examination in nine laboratories: of these, 591 (16%) were misclassified by visual examination and 294 (8%) were found to be degraded. The degree of discordance varied between locations, and laboratories received a higher number of degraded specimens from isolated health clinics. Cytological assessment of sputum was found to be feasible and identified areas for improvement in the Bolivian diagnostic system for TB.

  14. Video quality assessment using motion-compensated temporal filtering and manifold feature similarity

    PubMed Central

    Yu, Mei; Jiang, Gangyi; Shao, Feng; Peng, Zongju

    2017-01-01

    Well-performed Video quality assessment (VQA) method should be consistent with human visual systems for better prediction accuracy. In this paper, we propose a VQA method using motion-compensated temporal filtering (MCTF) and manifold feature similarity. To be more specific, a group of frames (GoF) is first decomposed into a temporal high-pass component (HPC) and a temporal low-pass component (LPC) by MCTF. Following this, manifold feature learning (MFL) and phase congruency (PC) are used to predict the quality of temporal LPC and temporal HPC respectively. The quality measures of the LPC and the HPC are then combined as GoF quality. A temporal pooling strategy is subsequently used to integrate GoF qualities into an overall video quality. The proposed VQA method appropriately processes temporal information in video by MCTF and temporal pooling strategy, and simulate human visual perception by MFL. Experiments on publicly available video quality database showed that in comparison with several state-of-the-art VQA methods, the proposed VQA method achieves better consistency with subjective video quality and can predict video quality more accurately. PMID:28445489

  15. Processes to Preserve Spice and Herb Quality and Sensory Integrity During Pathogen Inactivation

    PubMed Central

    Moberg, Kayla; Amin, Kemia N.; Wright, Melissa; Newkirk, Jordan J.; Ponder, Monica A.; Acuff, Gary R.; Dickson, James S.

    2017-01-01

    Abstract Selected processing methods, demonstrated to be effective at reducing Salmonella, were assessed to determine if spice and herb quality was affected. Black peppercorn, cumin seed, oregano, and onion powder were irradiated to a target dose of 8 kGy. Two additional processes were examined for whole black peppercorns and cumin seeds: ethylene oxide (EtO) fumigation and vacuum assisted‐steam (82.22 °C, 7.5 psia). Treated and untreated spices/herbs were compared (visual, odor) using sensory similarity testing protocols (α = 0.20; β = 0.05; proportion of discriminators: 20%) to determine if processing altered sensory quality. Analytical assessment of quality (color, water activity, and volatile chemistry) was completed. Irradiation did not alter visual or odor sensory quality of black peppercorn, cumin seed, or oregano but created differences in onion powder, which was lighter (higher L *) and more red (higher a*) in color, and resulted in nearly complete loss of measured volatile compounds. EtO processing did not create detectable odor or appearance differences in black peppercorn; however visual and odor sensory quality differences, supported by changes in color (higher b *; lower L *) and increased concentrations of most volatiles, were detected for cumin seeds. Steam processing of black peppercorn resulted in perceptible odor differences, supported by increased concentration of monoterpene volatiles and loss of all sesquiterpenes; only visual differences were noted for cumin seed. An important step in process validation is the verification that no effect is detectable from a sensory perspective. PMID:28407236

  16. Human Connectome Project Informatics: quality control, database services, and data visualization

    PubMed Central

    Marcus, Daniel S.; Harms, Michael P.; Snyder, Abraham Z.; Jenkinson, Mark; Wilson, J Anthony; Glasser, Matthew F.; Barch, Deanna M.; Archie, Kevin A.; Burgess, Gregory C.; Ramaratnam, Mohana; Hodge, Michael; Horton, William; Herrick, Rick; Olsen, Timothy; McKay, Michael; House, Matthew; Hileman, Michael; Reid, Erin; Harwell, John; Coalson, Timothy; Schindler, Jon; Elam, Jennifer S.; Curtiss, Sandra W.; Van Essen, David C.

    2013-01-01

    The Human Connectome Project (HCP) has developed protocols, standard operating and quality control procedures, and a suite of informatics tools to enable high throughput data collection, data sharing, automated data processing and analysis, and data mining and visualization. Quality control procedures include methods to maintain data collection consistency over time, to measure head motion, and to establish quantitative modality-specific overall quality assessments. Database services developed as customizations of the XNAT imaging informatics platform support both internal daily operations and open access data sharing. The Connectome Workbench visualization environment enables user interaction with HCP data and is increasingly integrated with the HCP's database services. Here we describe the current state of these procedures and tools and their application in the ongoing HCP study. PMID:23707591

  17. A visual grading study for different administered activity levels in bone scintigraphy.

    PubMed

    Gustafsson, Agnetha; Karlsson, Henrik; Nilsson, Kerstin A; Geijer, Håkan; Olsson, Anna

    2015-05-01

    The aim of the study is to assess the administered activity levels versus visual-based image quality using visual grading regression (VGR) including an assessment of the newly stated image criteria for whole-body bone scintigraphy. A total of 90 patients was included and grouped in three levels of administered activity: 400, 500 and 600 MBq. Six clinical image criteria regarding image quality was formulated by experienced nuclear medicine physicians. Visual grading was performed in all images, where three physicians rated the fulfilment of the image criteria on a four-step ordinal scale. The results were analysed using VGR. A count analysis was also made where the total number of counts in both views was registered. The administered activity of 600 MBq gives significantly better image quality than 400 MBq in five of six criteria (P<0·05). Comparing the administered activity of 600 MBq to 500 MBq, four criteria of six show significantly better image quality (P<0·05). The administered activity of 500 MBq gives no significantly better image quality than 400 Mbq (P<0·05). The count analysis shows that none of the three levels of administrated activity fulfil the recommendations by the EANM. There was a significant improvement in perceived image quality using an activity level of 600 MBq compared to lower activity levels in whole-body bone scintigraphy for the gamma camera equipment end set-up used in this study. This type of visual-based grading study seems to be a valuable tool and easy to implement in the clinical environment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. EAPhy: A Flexible Tool for High-throughput Quality Filtering of Exon-alignments and Data Processing for Phylogenetic Methods.

    PubMed

    Blom, Mozes P K

    2015-08-05

    Recently developed molecular methods enable geneticists to target and sequence thousands of orthologous loci and infer evolutionary relationships across the tree of life. Large numbers of genetic markers benefit species tree inference but visual inspection of alignment quality, as traditionally conducted, is challenging with thousands of loci. Furthermore, due to the impracticality of repeated visual inspection with alternative filtering criteria, the potential consequences of using datasets with different degrees of missing data remain nominally explored in most empirical phylogenomic studies. In this short communication, I describe a flexible high-throughput pipeline designed to assess alignment quality and filter exonic sequence data for subsequent inference. The stringency criteria for alignment quality and missing data can be adapted based on the expected level of sequence divergence. Each alignment is automatically evaluated based on the stringency criteria specified, significantly reducing the number of alignments that require visual inspection. By developing a rapid method for alignment filtering and quality assessment, the consistency of phylogenetic estimation based on exonic sequence alignments can be further explored across distinct inference methods, while accounting for different degrees of missing data.

  19. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  20. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  1. The role of the landscape architect in applied forest landscape management: a case study on process

    Treesearch

    Wayne Tlusty

    1979-01-01

    Land planning allocations are often multi-resource concepts, with visual quality objectives addressing the appropriate level of visual resource management. Current legislation and/or regulations often require interdisciplinary teams to implement planning decisions. A considerable amount of information is currently avail-able on visual assessment techniques both for...

  2. Simultaneous Analysis and Quality Assurance for Diffusion Tensor Imaging

    PubMed Central

    Lauzon, Carolyn B.; Asman, Andrew J.; Esparza, Michael L.; Burns, Scott S.; Fan, Qiuyun; Gao, Yurui; Anderson, Adam W.; Davis, Nicole; Cutting, Laurie E.; Landman, Bennett A.

    2013-01-01

    Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible. PMID:23637895

  3. Simultaneous analysis and quality assurance for diffusion tensor imaging.

    PubMed

    Lauzon, Carolyn B; Asman, Andrew J; Esparza, Michael L; Burns, Scott S; Fan, Qiuyun; Gao, Yurui; Anderson, Adam W; Davis, Nicole; Cutting, Laurie E; Landman, Bennett A

    2013-01-01

    Diffusion tensor imaging (DTI) enables non-invasive, cyto-architectural mapping of in vivo tissue microarchitecture through voxel-wise mathematical modeling of multiple magnetic resonance imaging (MRI) acquisitions, each differently sensitized to water diffusion. DTI computations are fundamentally estimation processes and are sensitive to noise and artifacts. Despite widespread adoption in the neuroimaging community, maintaining consistent DTI data quality remains challenging given the propensity for patient motion, artifacts associated with fast imaging techniques, and the possibility of hardware changes/failures. Furthermore, the quantity of data acquired per voxel, the non-linear estimation process, and numerous potential use cases complicate traditional visual data inspection approaches. Currently, quality inspection of DTI data has relied on visual inspection and individual processing in DTI analysis software programs (e.g. DTIPrep, DTI-studio). However, recent advances in applied statistical methods have yielded several different metrics to assess noise level, artifact propensity, quality of tensor fit, variance of estimated measures, and bias in estimated measures. To date, these metrics have been largely studied in isolation. Herein, we select complementary metrics for integration into an automatic DTI analysis and quality assurance pipeline. The pipeline completes in 24 hours, stores statistical outputs, and produces a graphical summary quality analysis (QA) report. We assess the utility of this streamlined approach for empirical quality assessment on 608 DTI datasets from pediatric neuroimaging studies. The efficiency and accuracy of quality analysis using the proposed pipeline is compared with quality analysis based on visual inspection. The unified pipeline is found to save a statistically significant amount of time (over 70%) while improving the consistency of QA between a DTI expert and a pool of research associates. Projection of QA metrics to a low dimensional manifold reveal qualitative, but clear, QA-study associations and suggest that automated outlier/anomaly detection would be feasible.

  4. Visual and Statistical Analysis of Digital Elevation Models Generated Using Idw Interpolator with Varying Powers

    NASA Astrophysics Data System (ADS)

    Asal, F. F.

    2012-07-01

    Digital elevation data obtained from different Engineering Surveying techniques is utilized in generating Digital Elevation Model (DEM), which is employed in many Engineering and Environmental applications. This data is usually in discrete point format making it necessary to utilize an interpolation approach for the creation of DEM. Quality assessment of the DEM is a vital issue controlling its use in different applications; however this assessment relies heavily on statistical methods with neglecting the visual methods. The research applies visual analysis investigation on DEMs generated using IDW interpolator of varying powers in order to examine their potential in the assessment of the effects of the variation of the IDW power on the quality of the DEMs. Real elevation data has been collected from field using total station instrument in a corrugated terrain. DEMs have been generated from the data at a unified cell size using IDW interpolator with power values ranging from one to ten. Visual analysis has been undertaken using 2D and 3D views of the DEM; in addition, statistical analysis has been performed for assessment of the validity of the visual techniques in doing such analysis. Visual analysis has shown that smoothing of the DEM decreases with the increase in the power value till the power of four; however, increasing the power more than four does not leave noticeable changes on 2D and 3D views of the DEM. The statistical analysis has supported these results where the value of the Standard Deviation (SD) of the DEM has increased with increasing the power. More specifically, changing the power from one to two has produced 36% of the total increase (the increase in SD due to changing the power from one to ten) in SD and changing to the powers of three and four has given 60% and 75% respectively. This refers to decrease in DEM smoothing with the increase in the power of the IDW. The study also has shown that applying visual methods supported by statistical analysis has proven good potential in the DEM quality assessment.

  5. Visual quality analysis for images degraded by different types of noise

    NASA Astrophysics Data System (ADS)

    Ponomarenko, Nikolay N.; Lukin, Vladimir V.; Ieremeyev, Oleg I.; Egiazarian, Karen O.; Astola, Jaakko T.

    2013-02-01

    Modern visual quality metrics take into account different peculiarities of the Human Visual System (HVS). One of them is described by the Weber-Fechner law and deals with the different sensitivity to distortions in image fragments with different local mean values (intensity, brightness). We analyze how this property can be incorporated into a metric PSNRHVS- M. It is shown that some improvement of its performance can be provided. Then, visual quality of color images corrupted by three types of i.i.d. noise (pure additive, pure multiplicative, and signal dependent, Poisson) is analyzed. Experiments with a group of observers are carried out for distorted color images created on the basis of TID2008 database. Several modern HVS-metrics are considered. It is shown that even the best metrics are unable to assess visual quality of distorted images adequately enough. The reasons for this deal with the observer's attention to certain objects in the test images, i.e., with semantic aspects of vision, which are worth taking into account in design of HVS-metrics.

  6. Hawkeye and AMOS: visualizing and assessing the quality of genome assemblies

    PubMed Central

    Schatz, Michael C.; Phillippy, Adam M.; Sommer, Daniel D.; Delcher, Arthur L.; Puiu, Daniela; Narzisi, Giuseppe; Salzberg, Steven L.; Pop, Mihai

    2013-01-01

    Since its launch in 2004, the open-source AMOS project has released several innovative DNA sequence analysis applications including: Hawkeye, a visual analytics tool for inspecting the structure of genome assemblies; the Assembly Forensics and FRCurve pipelines for systematically evaluating the quality of a genome assembly; and AMOScmp, the first comparative genome assembler. These applications have been used to assemble and analyze dozens of genomes ranging in complexity from simple microbial species through mammalian genomes. Recent efforts have been focused on enhancing support for new data characteristics brought on by second- and now third-generation sequencing. This review describes the major components of AMOS in light of these challenges, with an emphasis on methods for assessing assembly quality and the visual analytics capabilities of Hawkeye. These interactive graphical aspects are essential for navigating and understanding the complexities of a genome assembly, from the overall genome structure down to individual bases. Hawkeye and AMOS are available open source at http://amos.sourceforge.net. PMID:22199379

  7. A new multimodal interactive way of subjective scoring of 3D video quality of experience

    NASA Astrophysics Data System (ADS)

    Kim, Taewan; Lee, Kwanghyun; Lee, Sanghoon; Bovik, Alan C.

    2014-03-01

    People that watch today's 3D visual programs, such as 3D cinema, 3D TV and 3D games, experience wide and dynamically varying ranges of 3D visual immersion and 3D quality of experience (QoE). It is necessary to be able to deploy reliable methodologies that measure each viewers subjective experience. We propose a new methodology that we call Multimodal Interactive Continuous Scoring of Quality (MICSQ). MICSQ is composed of a device interaction process between the 3D display and a separate device (PC, tablet, etc.) used as an assessment tool, and a human interaction process between the subject(s) and the device. The scoring process is multimodal, using aural and tactile cues to help engage and focus the subject(s) on their tasks. Moreover, the wireless device interaction process makes it possible for multiple subjects to assess 3D QoE simultaneously in a large space such as a movie theater, and at di®erent visual angles and distances.

  8. An enhanced functional ability questionnaire (faVIQ) to measure the impact of rehabilitation services on the visually impaired

    PubMed Central

    Wolffsohn, James Stuart; Jackson, Jonathan; Hunt, Olivia Anne; Cottriall, Charles; Lindsay, Jennifer; Gilmour, Richard; Sinclair, Anne; Harper, Robert

    2014-01-01

    AIM To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. METHODS Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual impairment. RESULTS Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. CONCLUSION The faVIQ allows sensitive assessment of quality-of-life in the visually impaired and should support studies which evaluate the effectiveness of low vision rehabilitation services. PMID:24634868

  9. An enhanced functional ability questionnaire (faVIQ) to measure the impact of rehabilitation services on the visually impaired.

    PubMed

    Wolffsohn, James Stuart; Jackson, Jonathan; Hunt, Olivia Anne; Cottriall, Charles; Lindsay, Jennifer; Gilmour, Richard; Sinclair, Anne; Harper, Robert

    2014-01-01

    To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual impairment. Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. The faVIQ allows sensitive assessment of quality-of-life in the visually impaired and should support studies which evaluate the effectiveness of low vision rehabilitation services.

  10. Visual quality evaluation of urban commercial streetscape for the development of landscape visual planning system in provincial street corridors in Malang, Indonesia

    NASA Astrophysics Data System (ADS)

    Santosa, H.; Ernawati, J.; Wulandari, L. D.

    2018-03-01

    The visual aesthetic experience in urban spaces is important in establishing a comfortable and satisfying experience for the community. The embodiment of a good visual image of urban space will encourage the emergence of positive perceptions and meanings stimulating the community to produce a good reaction to its urban space. Moreover, to establish a Good Governance in urban planning and design, it is necessary to boost and promote a community participation in the process of controlling the visual quality of urban space through the visual quality evaluation on urban street corridors. This study is an early stage as part of the development of ‘Landscape Visual Planning System’ on the commercial street corridor in Malang. Accordingly, the research aims to evaluate the physical characteristics and the public preferences of the spatial and visual aspects in five provincial road corridors in Malang. This study employs a field survey methods, and an environmental aesthetics approach through semantic differential method. The result of the identification of physical characteristics and the assessment of public preferences on the spatial and visual aspects of the five provincial streets serve as the basis for constructing the 3d interactive simulation scenarios in the Landscape Visual Planning System.

  11. Visual communication - Information and fidelity. [of images

    NASA Technical Reports Server (NTRS)

    Huck, Freidrich O.; Fales, Carl L.; Alter-Gartenberg, Rachel; Rahman, Zia-Ur; Reichenbach, Stephen E.

    1993-01-01

    This assessment of visual communication deals with image gathering, coding, and restoration as a whole rather than as separate and independent tasks. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image. Past applications of these criteria to the assessment of image coding and restoration have been limited to the link that connects the output of the image-gathering device to the input of the image-display device. By contrast, the approach presented in this paper explicitly includes the critical limiting factors that constrain image gathering and display. This extension leads to an end-to-end assessment theory of visual communication that combines optical design with digital processing.

  12. The Impact of Visual Disability on the Quality of Life of Older Persons in Rural Northeast Thailand

    ERIC Educational Resources Information Center

    La Grow, Steven; Sudnongbua, Supaporn; Boddy, Julie

    2011-01-01

    A high rate of self-reported visual disability was found among a sample of persons aged 60 and older in the course of a study that assessed the impact of feelings of abandonment among older persons in a remote rural area in northeast Thailand (Sudnongbua, La Grow, & Boddy, 2010). This study assessed the impact of self-reported visual…

  13. Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.

    PubMed

    Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki

    2014-02-01

    To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.

  14. A visual resource management study of alternative dams, reservoirs and highway and transmission line corridors near Copper Creek, Washington

    Treesearch

    John Ady; Brian A. Gray; Grant R. Jones

    1979-01-01

    Three alternative dams have been considered by Seattle City Light for the Skagit River Narrows in the North Cascades National Recreation Area, Washington. The authors assessed the area's existing visual resources, identified three alternative highway and transmission line realignments, evaluated changes in visual character and quality for 13 different combinations...

  15. Information, entropy, and fidelity in visual communication

    NASA Astrophysics Data System (ADS)

    Huck, Friedrich O.; Fales, Carl L.; Alter-Gartenberg, Rachel; Rahman, Zia-ur

    1992-10-01

    This paper presents an assessment of visual communication that integrates the critical limiting factors of image gathering an display with the digital processing that is used to code and restore images. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image.

  16. Information, entropy and fidelity in visual communication

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Fales, Carl L.; Alter-Gartenberg, Rachel; Rahman, Zia-Ur

    1992-01-01

    This paper presents an assessment of visual communication that integrates the critical limiting factors of image gathering and display with the digital processing that is used to code and restore images. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image.

  17. Assessment of quality of life in patients with visual impairments using a new visual function questionnaire: the VFQ-J11

    PubMed Central

    Nakano, Tadashi; Kawashima, Motoko; Hiratsuka, Yoshimune; Tamura, Hiroshi; Ono, Koichi; Murakami, Akira; Tsubota, Kazuo; Yamada, Masakazu

    2016-01-01

    Background The purpose of the present study was to assess the vision-related quality of life (QOL) of visually impaired patients using the Japanese 11-item National Eye Institute Visual Function Questionnaire (VFQ-J11). Comparisons with the 25-item version (VFQ-25) and the EuroQoL Index using a large group of patients with various degrees of impairments and various causative diseases were performed. Methods A total of 232 visually impaired Japanese patients were recruited from six ophthalmology departments in Japan. Information on ophthalmic findings and patient backgrounds was collected, and information on QOL and utility assessments was collected from the patients by means of survey questionnaires. Results The average age of patients was 69.6±14.3 years. Both the vision-related QOL scores (VFQ-25 composite and VFQ-J11) were significantly associated with better and worse visual acuity (VA) in visually impaired subjects (all P<0.01). VFQ-J11 was comparable to VFQ-25 regardless of causative diseases. VFQ-25 composite and the VFQ-J11 scores were concurrently associated with a range of systemic medical disorders. EuroQoL Index had a significant association with better eye VA (P<0.01), but not with worse eye VA, or any systemic disorders. Conclusion VFQ-J11 provides valid data on vision-related QOL and is less of a burden for patients with vision problems. PMID:27784982

  18. Reflections on Assessment

    ERIC Educational Resources Information Center

    DiRanna, Kathy; Osmundson, Ellen; Topps, Jo; Gearhart, Maryl

    2008-01-01

    In this article, the authors describe an assessment-centered teaching (ACT) framework they developed to communicate the integration of assessment and instruction. The framework is a visual representation of the relationships among the fundamental elements of assessment knowledge: the characteristics of quality goals for student learning and…

  19. Wavefront-Guided Scleral Lens Correction in Keratoconus

    PubMed Central

    Marsack, Jason D.; Ravikumar, Ayeswarya; Nguyen, Chi; Ticak, Anita; Koenig, Darren E.; Elswick, James D.; Applegate, Raymond A.

    2014-01-01

    Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population. PMID:24830371

  20. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.

    PubMed

    Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J

    2012-02-01

    To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.

  1. Airborne ultrasonic inspection of hides and leather

    USDA-ARS?s Scientific Manuscript database

    Currently, hides and leather are visually inspected and ranked for quality, sale price and usable area. Visual inspection is not reliable for detecting defects, which are usually hidden inside the material. This manual assessment is non-uniform among operators, and often leads to disputes over fai...

  2. Evaluation of hides and leather using ultrasonic technology

    USDA-ARS?s Scientific Manuscript database

    Hides are visually inspected and ranked for quality and sale price. Because visual inspection is not reliable for detecting defects when hair is present, hides cannot be effectively sorted at the earliest stage of processing. Furthermore, this subjective assessment is non-uniform among operators, ...

  3. Comprehensive model for predicting perceptual image quality of smart mobile devices.

    PubMed

    Gong, Rui; Xu, Haisong; Luo, M R; Li, Haifeng

    2015-01-01

    An image quality model for smart mobile devices was proposed based on visual assessments of several image quality attributes. A series of psychophysical experiments were carried out on two kinds of smart mobile devices, i.e., smart phones and tablet computers, in which naturalness, colorfulness, brightness, contrast, sharpness, clearness, and overall image quality were visually evaluated under three lighting environments via categorical judgment method for various application types of test images. On the basis of Pearson correlation coefficients and factor analysis, the overall image quality could first be predicted by its two constituent attributes with multiple linear regression functions for different types of images, respectively, and then the mathematical expressions were built to link the constituent image quality attributes with the physical parameters of smart mobile devices and image appearance factors. The procedure and algorithms were applicable to various smart mobile devices, different lighting conditions, and multiple types of images, and performance was verified by the visual data.

  4. Processes to Preserve Spice and Herb Quality and Sensory Integrity During Pathogen Inactivation.

    PubMed

    Duncan, Susan E; Moberg, Kayla; Amin, Kemia N; Wright, Melissa; Newkirk, Jordan J; Ponder, Monica A; Acuff, Gary R; Dickson, James S

    2017-05-01

    Selected processing methods, demonstrated to be effective at reducing Salmonella, were assessed to determine if spice and herb quality was affected. Black peppercorn, cumin seed, oregano, and onion powder were irradiated to a target dose of 8 kGy. Two additional processes were examined for whole black peppercorns and cumin seeds: ethylene oxide (EtO) fumigation and vacuum assisted-steam (82.22 °C, 7.5 psia). Treated and untreated spices/herbs were compared (visual, odor) using sensory similarity testing protocols (α = 0.20; β = 0.05; proportion of discriminators: 20%) to determine if processing altered sensory quality. Analytical assessment of quality (color, water activity, and volatile chemistry) was completed. Irradiation did not alter visual or odor sensory quality of black peppercorn, cumin seed, or oregano but created differences in onion powder, which was lighter (higher L * ) and more red (higher a * ) in color, and resulted in nearly complete loss of measured volatile compounds. EtO processing did not create detectable odor or appearance differences in black peppercorn; however visual and odor sensory quality differences, supported by changes in color (higher b * ; lower L * ) and increased concentrations of most volatiles, were detected for cumin seeds. Steam processing of black peppercorn resulted in perceptible odor differences, supported by increased concentration of monoterpene volatiles and loss of all sesquiterpenes; only visual differences were noted for cumin seed. An important step in process validation is the verification that no effect is detectable from a sensory perspective. © 2017 The Authors. Journal of Food Science published by Wiley Periodicals, Inc. on behalf of Institute of Food Technologists.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Like; Kang, Jian, E-mail: j.kang@sheffield.ac.uk; Schroth, Olaf

    Large scale transportation projects can adversely affect the visual perception of environmental quality and require adequate visual impact assessment. In this study, we investigated the effects of the characteristics of the road project and the character of the existing landscape on the perceived visual impact of motorways, and developed a GIS-based prediction model based on the findings. An online survey using computer-visualised scenes of different motorway and landscape scenarios was carried out to obtain perception-based judgements on the visual impact. Motorway scenarios simulated included the baseline scenario without road, original motorway, motorways with timber noise barriers, transparent noise barriers andmore » tree screen; different landscape scenarios were created by changing land cover of buildings and trees in three distance zones. The landscape content of each scene was measured in GIS. The result shows that presence of a motorway especially with the timber barrier significantly decreases the visual quality of the view. The resulted visual impact tends to be lower where it is less visually pleasant with more buildings in the view, and can be slightly reduced by the visual absorption effect of the scattered trees between the motorway and the viewpoint. Based on the survey result, eleven predictors were identified for the visual impact prediction model which was applied in GIS to generate maps of visual impact of motorways in different scenarios. The proposed prediction model can be used to achieve efficient and reliable assessment of visual impact of motorways. - Highlights: • Motorways induce significant visual impact especially with timber noise barriers. • Visual impact is negatively correlated with amount of buildings in the view. • Visual impact is positively correlated with percentage of trees in the view. • Perception-based motorway visual impact prediction model using mapped predictors • Predicted visual impacts in different scenarios are mapped in GIS.« less

  6. Health-related quality of life of cataract patients: cross-cultural comparisons of utility and psychometric measures.

    PubMed

    Lee, Jae Eun; Fos, Peter J; Zuniga, Miguel A; Kastl, Peter R; Sung, Jung Hye

    2003-07-01

    This study was conducted to assess the presence and/or absence of cross-cultural differences or similarities between Korean and United States cataract patients. A systematic assessment was performed using utility and psychometric measures in the study population. A cross-sectional study design was used to examine the comparison of preoperative outcomes measures in cataract patients in Korea and the United States. Study subjects were selected using non-probabilistic methods and included 132 patients scheduled for cataract surgery in one eye. Subjects were adult cataract patients at Samsung and Kunyang General Hospital in Seoul, Korea, and Tulane University Hospital and Clinics in New Orleans, Louisiana. Preoperative utility was assessed using the verbal rating scale and standard reference gamble techniques. Current preoperative health status was assessed using the SF-36 and VF-14 surveys. Current preoperative Snellen visual acuity was used as a clinical measure of vision status. Korean patients were more likely to be younger (p = 0.001), less educated (p = 0.001), and to have worse Snellen visual acuity (p = 0.002) than United States patients. Multivariate analysis of variance (MANOVA) revealed that in contrast to Korean patients, United States patients were assessed to have higher scoring in general health, vitality, VF-14, and verbal rating for visual health. This higher scoring trend persisted after controlling for age, gender, education and Snellen visual acuity. The difference in health-related quality of life (HRQOL) between the two countries was quite clear, especially in the older age and highly educated group. Subjects in Korea and the United States were significantly different in quality of life, functional status and clinical outcomes. Subjects in the United States had more favorable health outcomes than those in Korea. These differences may be caused by multiple factors, including country-specific differences in economic status, health care system, cultural value system, and health policy. Cross-cultural differences should be considered when making international comparisons of quality of life.

  7. The multiple sclerosis visual pathway cohort: understanding neurodegeneration in MS.

    PubMed

    Martínez-Lapiscina, Elena H; Fraga-Pumar, Elena; Gabilondo, Iñigo; Martínez-Heras, Eloy; Torres-Torres, Ruben; Ortiz-Pérez, Santiago; Llufriu, Sara; Tercero, Ana; Andorra, Magi; Roca, Marc Figueras; Lampert, Erika; Zubizarreta, Irati; Saiz, Albert; Sanchez-Dalmau, Bernardo; Villoslada, Pablo

    2014-12-15

    Multiple Sclerosis (MS) is an immune-mediated disease of the Central Nervous System with two major underlying etiopathogenic processes: inflammation and neurodegeneration. The latter determines the prognosis of this disease. MS is the main cause of non-traumatic disability in middle-aged populations. The MS-VisualPath Cohort was set up to study the neurodegenerative component of MS using advanced imaging techniques by focusing on analysis of the visual pathway in a middle-aged MS population in Barcelona, Spain. We started the recruitment of patients in the early phase of MS in 2010 and it remains permanently open. All patients undergo a complete neurological and ophthalmological examination including measurements of physical and disability (Expanded Disability Status Scale; Multiple Sclerosis Functional Composite and neuropsychological tests), disease activity (relapses) and visual function testing (visual acuity, color vision and visual field). The MS-VisualPath protocol also assesses the presence of anxiety and depressive symptoms (Hospital Anxiety and Depression Scale), general quality of life (SF-36) and visual quality of life (25-Item National Eye Institute Visual Function Questionnaire with the 10-Item Neuro-Ophthalmic Supplement). In addition, the imaging protocol includes both retinal (Optical Coherence Tomography and Wide-Field Fundus Imaging) and brain imaging (Magnetic Resonance Imaging). Finally, multifocal Visual Evoked Potentials are used to perform neurophysiological assessment of the visual pathway. The analysis of the visual pathway with advance imaging and electrophysilogical tools in parallel with clinical information will provide significant and new knowledge regarding neurodegeneration in MS and provide new clinical and imaging biomarkers to help monitor disease progression in these patients.

  8. Evolution of a visual impact model to evaluate nuclear plant siting and design option

    Treesearch

    Brian A. Gray; John Ady; Grant R. Jones

    1979-01-01

    The development of a visual impact method- elegy is reviewed from first concepts (1973) to application.3/ The method can be used to train evaluators to use explicit criteria (vividness, intactness and unity) to assess change in a setting's visual quality as the result of construction of a nuclear facility, or any other visible alteration. Slides of "before...

  9. Visual Health and Visual Healthcare Access in Refugees and Displaced Persons: A Systematic Review.

    PubMed

    Bal, Sila; Duckles, Anne; Buttenheim, Alison

    2018-06-02

    Vision impairment is a significant global health concern. Still, there remains a gap in our knowledge of visual health in refugees. We conducted a systematic review of the distinctive eye care needs of refugees. We screened PubMed, EMBASE, and Web of Science through February 17, 2017 for studies that focused primarily on visual health in refugees. Risk of bias was assessed using the National Heart, Lung, and Blood Institute quality assessment tools. 26 studies were included in the final review. The prevalence of blindness ranged from 1.3 to 26.2%. Trachoma was the leading infectious cause. Only four studies assessed vision-related care. Time/location of displacement, social unrest, and sanitation impacted severity of eye disease. Refugees have unique eye care needs. Public health interventions should target eye care at every stage of displacement. Providers may use these results to inform future research and improve visual healthcare access in refugee groups.

  10. Setting visual pre-placement testing in a technology manufacturing environment.

    PubMed

    Gowan, Nancy J

    2014-01-01

    Every day we use our eyes to perform activities of daily living and work. Aging changes as well as health conditions can impact an individual's visual function, making it more difficult to accurately perform work activities. Occupational therapists work closely with optometrists and employers to develop ways to accommodate for these changes so that the employee can continue to perform the work tasks. This manuscript outlines a case study of systematically developing visual demands analyses and pre-placement vision screening assessment protocols for individuals completing quality inspection positions. When the vision screening was completed, it was discovered that over 20% of the employees had visual deficits that were correctable. This screening process yielded improved quality results but also identification of previously undetected visual deficits. Further development of vision screening in the workplace is supported.

  11. Using Saliency-Weighted Disparity Statistics for Objective Visual Comfort Assessment of Stereoscopic Images

    NASA Astrophysics Data System (ADS)

    Zhang, Wenlan; Luo, Ting; Jiang, Gangyi; Jiang, Qiuping; Ying, Hongwei; Lu, Jing

    2016-06-01

    Visual comfort assessment (VCA) for stereoscopic images is a particularly significant yet challenging task in 3D quality of experience research field. Although the subjective assessment given by human observers is known as the most reliable way to evaluate the experienced visual discomfort, it is time-consuming and non-systematic. Therefore, it is of great importance to develop objective VCA approaches that can faithfully predict the degree of visual discomfort as human beings do. In this paper, a novel two-stage objective VCA framework is proposed. The main contribution of this study is that the important visual attention mechanism of human visual system is incorporated for visual comfort-aware feature extraction. Specifically, in the first stage, we first construct an adaptive 3D visual saliency detection model to derive saliency map of a stereoscopic image, and then a set of saliency-weighted disparity statistics are computed and combined to form a single feature vector to represent a stereoscopic image in terms of visual comfort. In the second stage, a high dimensional feature vector is fused into a single visual comfort score by performing random forest algorithm. Experimental results on two benchmark databases confirm the superior performance of the proposed approach.

  12. Attention Guidance in Learning from a Complex Animation: Seeing Is Understanding?

    ERIC Educational Resources Information Center

    de Koning, Bjorn B.; Tabbers, Huib K.; Rikers, Remy M. J. P.; Paas, Fred

    2010-01-01

    To examine how visual attentional resources are allocated when learning from a complex animation about the cardiovascular system, eye movements were registered in the absence and presence of visual cues. Cognitive processing was assessed using cued retrospective reporting, whereas comprehension and transfer tests measured the quality of the…

  13. Vision and quality-of-life.

    PubMed Central

    Brown, G C

    1999-01-01

    OBJECTIVE: To determine the relationship of visual acuity loss to quality of life. DESIGN: Three hundred twenty-five patients with visual loss to a minimum of 20/40 or greater in at least 1 eye were interviewed in a standardized fashion using a modified VF-14, questionnaire. Utility values were also obtained using both the time trade-off and standard gamble methods of utility assessment. MAIN OUTCOME MEASURES: Best-corrected visual acuity was correlated with the visual function score on the modified VF-14 questionnaire, as well as with utility values obtained using both the time trade-off and standard gamble methods. RESULTS: Decreasing levels of vision in the eye with better acuity correlated directly with decreasing visual function scores on the modified VF-14 questionnaire, as did decreasing utility values using the time trade-off method of utility evaluation. The standard gamble method of utility evaluation was not as directly correlated with vision as the time trade-off method. Age, level of education, gender, race, length of time of visual loss, and the number of associated systemic comorbidities did not significantly affect the time trade-off utility values associated with visual loss in the better eye. The level of reduced vision in the better eye, rather than the specific disease process causing reduced vision, was related to mean utility values. The average person with 20/40 vision in the better seeing eye was willing to trade 2 of every 10 years of life in return for perfect vision (utility value of 0.8), while the average person with counting fingers vision in the better eye was willing to trade approximately 5 of every 10 remaining years of life (utility value of 0.52) in return for perfect vision. CONCLUSIONS: The time trade-off method of utility evaluation appears to be an effective method for assessing quality of life associated with visual loss. Time trade-off utility values decrease in direct conjunction with decreasing vision in the better-seeing eye. Unlike the modified VF-14 test and its counterparts, utility values allow the quality of life associated with visual loss to be more readily compared to the quality of life associated with other health (disease) states. This information can be employed for cost-effective analyses that objectively compare evidence-based medicine, patient-based preferences and sound econometric principles across all specialties in health care. PMID:10703139

  14. Despeckle filtering software toolbox for ultrasound imaging of the common carotid artery.

    PubMed

    Loizou, Christos P; Theofanous, Charoula; Pantziaris, Marios; Kasparis, Takis

    2014-04-01

    Ultrasound imaging of the common carotid artery (CCA) is a non-invasive tool used in medicine to assess the severity of atherosclerosis and monitor its progression through time. It is also used in border detection and texture characterization of the atherosclerotic carotid plaque in the CCA, the identification and measurement of the intima-media thickness (IMT) and the lumen diameter that all are very important in the assessment of cardiovascular disease (CVD). Visual perception, however, is hindered by speckle, a multiplicative noise, that degrades the quality of ultrasound B-mode imaging. Noise reduction is therefore essential for improving the visual observation quality or as a pre-processing step for further automated analysis, such as image segmentation of the IMT and the atherosclerotic carotid plaque in ultrasound images. In order to facilitate this preprocessing step, we have developed in MATLAB(®) a unified toolbox that integrates image despeckle filtering (IDF), texture analysis and image quality evaluation techniques to automate the pre-processing and complement the disease evaluation in ultrasound CCA images. The proposed software, is based on a graphical user interface (GUI) and incorporates image normalization, 10 different despeckle filtering techniques (DsFlsmv, DsFwiener, DsFlsminsc, DsFkuwahara, DsFgf, DsFmedian, DsFhmedian, DsFad, DsFnldif, DsFsrad), image intensity normalization, 65 texture features, 15 quantitative image quality metrics and objective image quality evaluation. The software is publicly available in an executable form, which can be downloaded from http://www.cs.ucy.ac.cy/medinfo/. It was validated on 100 ultrasound images of the CCA, by comparing its results with quantitative visual analysis performed by a medical expert. It was observed that the despeckle filters DsFlsmv, and DsFhmedian improved image quality perception (based on the expert's assessment and the image texture and quality metrics). It is anticipated that the system could help the physician in the assessment of cardiovascular image analysis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Public perceptions of west-side forests: improving visual impact assessments and designing thinnings and harvests for scenic integrity

    Treesearch

    Robert G. Ribe

    2013-01-01

    Perceptions of public forests’ acceptability can be infl uenced by aesthetic qualities, at both broad and project levels, aff ecting managers’ social license to act. Legal and methodological issues related to measuring and managing forest aesthetics in NEPA and NFMA decision-making are discussed. It is argued that conventional visual impact assessments—using...

  16. CellProfiler Tracer: exploring and validating high-throughput, time-lapse microscopy image data.

    PubMed

    Bray, Mark-Anthony; Carpenter, Anne E

    2015-11-04

    Time-lapse analysis of cellular images is an important and growing need in biology. Algorithms for cell tracking are widely available; what researchers have been missing is a single open-source software package to visualize standard tracking output (from software like CellProfiler) in a way that allows convenient assessment of track quality, especially for researchers tuning tracking parameters for high-content time-lapse experiments. This makes quality assessment and algorithm adjustment a substantial challenge, particularly when dealing with hundreds of time-lapse movies collected in a high-throughput manner. We present CellProfiler Tracer, a free and open-source tool that complements the object tracking functionality of the CellProfiler biological image analysis package. Tracer allows multi-parametric morphological data to be visualized on object tracks, providing visualizations that have already been validated within the scientific community for time-lapse experiments, and combining them with simple graph-based measures for highlighting possible tracking artifacts. CellProfiler Tracer is a useful, free tool for inspection and quality control of object tracking data, available from http://www.cellprofiler.org/tracer/.

  17. Quality and Cultural Sensitivity of Linguistically Appropriate Cardiovascular Disease Information for Chinese Immigrants: A Review of Online Resources From Heart Foundations.

    PubMed

    Li, Jialin; Lowres, Nicole; Jin, Kai; Zhang, Ling; Neubeck, Lis; Gallagher, Robyn

    Chinese immigrants are at an increased risk for cardiovascular diseases (CVDs) compared with Chinese nationals partly because of lifestyle changes and knowledge deficits. Translated patient resources are available on the Internet and are often provided by health professionals; however, the quality and cultural sensitivity of these resources have not been reported. The aim of this study was to assess the availability, quality, and cultural sensitivity of Chinese-language information available from national "Heart Foundations" (cardiac research bodies, nongovernmental organisations) of the 5 most popular destinations of Chinese immigration. This study is a descriptive research in which national "Heart Foundation" websites were systematically searched for Chinese-language CVD patient education resources. Quality (content, identification, structure) was assessed using the Ensuring Quality Information for Patients instrument. Cultural sensitivity was evaluated using the Cultural Sensitivity Assessment Tool. From 107 identified resources, 33 were CVD specific: coronary heart disease (n = 20), arrhythmias (n = 7), and heart failure (n = 6). Quality of resources was adequate (mean Ensuring Quality Information for Patients score, 69%), but scores varied significantly (min, 60%; max, 85%). Although all resources were classified as culturally sensitive (Cultural Sensitivity Assessment Tool score ≥ 2.5), 2 resources scored low (≤2.5) for visual impact, and across all resources, written and visual domains were assessed as least culturally sensitive. Most resources lacked culturally specific references. Chinese-language CVD resources were inconsistent in the supply of key information. Quality and level of cultural sensitivity were adequate, but most resources lacked culturally specific references. Comprehensive, high-quality CVD resources powered by Editorial Manager and ProduXion Manager from Aries Systems Corporation tailored for Chinese immigrants are urgently needed for healthcare providers to support CVD education and care of patients belonging to this population.

  18. BatMass: a Java Software Platform for LC-MS Data Visualization in Proteomics and Metabolomics.

    PubMed

    Avtonomov, Dmitry M; Raskind, Alexander; Nesvizhskii, Alexey I

    2016-08-05

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC-MS-based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC-MS data are often overlooked, and assessment of an experiment's success is based on some derived metrics such as "the number of identified compounds". The human brain interprets visual data much better than plain text, hence the saying "a picture is worth a thousand words". Here, we present the BatMass software package, which allows for performing quick quality control of raw LC-MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC-MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration.

  19. BatMass: a Java software platform for LC/MS data visualization in proteomics and metabolomics

    PubMed Central

    Avtonomov, Dmitry; Raskind, Alexander; Nesvizhskii, Alexey I.

    2017-01-01

    Mass spectrometry (MS) coupled to liquid chromatography (LC) is a commonly used technique in metabolomic and proteomic research. As the size and complexity of LC/MS based experiments grow, it becomes increasingly more difficult to perform quality control of both raw data and processing results. In a practical setting, quality control steps for raw LC/MS data are often overlooked and assessment of an experiment's success is based on some derived metrics such as “the number of identified compounds”. Human brain interprets visual data much better than plain text, hence the saying “a picture is worth a thousand words”. Here we present BatMass software package which allows to perform quick quality control of raw LC/MS data through its fast visualization capabilities. It also serves as a testbed for developers of LC/MS data processing algorithms by providing a data access library for open mass spectrometry file formats and a means of visually mapping processing results back to the original data. We illustrate the utility of BatMass with several use cases of quality control and data exploration. PMID:27306858

  20. Colometer: a real-time quality feedback system for screening colonoscopy.

    PubMed

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.

  1. Effect of soil in nutrient cycle assessment at dairy farms

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Maricke; de Boer, Imke; van Dam, Jos; van Middelaar, Corina; Stoof, Cathelijne

    2016-04-01

    Annual farm nutrient cycle assessments give valuable insight in the nutrient cycles and nutrient losses at dairy farms. It describes nutrient use efficiencies for the entire farm and for the underlying components cattle, manure, crops and soil. In many modelling studies, soil is kept as a constant factor, while soil quality is vital for soil functioning of the ecosystem. Improving soil quality will improve the nutrient cycle, and will also have positive effect on the soil functions crop production, water cycling and greenhouse gas mitigation. Spatial variation of soil properties within a farm, however, are not included in annual nutrient cycle assessments. Therefore it is impossible to identify fields where most profit can be gained by improving farm management at field level, and it is not possible to identify and to quantify nutrient flow path ways. The aim of this study is to develop a framework to improve the annual nutrient cycle assessment at Dutch dairy farms, by including soil properties and their spatial variation within farms. Soil type and soil quality will be described by visual soil assessment of soil quality characteristics. The visual observations will be linked to the nutrient cycle assessment, using soil-hydrological model SWAP. We will demonstrate how soil quality at field level can impact on crop production, eutrophication potential and greenhouse gas potential at farm level. Also, we will show how this framework can be used by farmers to improve their farm management. This new approach is focusing on annual nutrient cycle assessment, but could also be used in life cycle assessment. It will improve understanding of soil functioning and dairy farm management.

  2. Nonlinear dimensionality reduction methods for synthetic biology biobricks' visualization.

    PubMed

    Yang, Jiaoyun; Wang, Haipeng; Ding, Huitong; An, Ning; Alterovitz, Gil

    2017-01-19

    Visualizing data by dimensionality reduction is an important strategy in Bioinformatics, which could help to discover hidden data properties and detect data quality issues, e.g. data noise, inappropriately labeled data, etc. As crowdsourcing-based synthetic biology databases face similar data quality issues, we propose to visualize biobricks to tackle them. However, existing dimensionality reduction methods could not be directly applied on biobricks datasets. Hereby, we use normalized edit distance to enhance dimensionality reduction methods, including Isomap and Laplacian Eigenmaps. By extracting biobricks from synthetic biology database Registry of Standard Biological Parts, six combinations of various types of biobricks are tested. The visualization graphs illustrate discriminated biobricks and inappropriately labeled biobricks. Clustering algorithm K-means is adopted to quantify the reduction results. The average clustering accuracy for Isomap and Laplacian Eigenmaps are 0.857 and 0.844, respectively. Besides, Laplacian Eigenmaps is 5 times faster than Isomap, and its visualization graph is more concentrated to discriminate biobricks. By combining normalized edit distance with Isomap and Laplacian Eigenmaps, synthetic biology biobircks are successfully visualized in two dimensional space. Various types of biobricks could be discriminated and inappropriately labeled biobricks could be determined, which could help to assess crowdsourcing-based synthetic biology databases' quality, and make biobricks selection.

  3. A CNN based neurobiology inspired approach for retinal image quality assessment.

    PubMed

    Mahapatra, Dwarikanath; Roy, Pallab K; Sedai, Suman; Garnavi, Rahil

    2016-08-01

    Retinal image quality assessment (IQA) algorithms use different hand crafted features for training classifiers without considering the working of the human visual system (HVS) which plays an important role in IQA. We propose a convolutional neural network (CNN) based approach that determines image quality using the underlying principles behind the working of the HVS. CNNs provide a principled approach to feature learning and hence higher accuracy in decision making. Experimental results demonstrate the superior performance of our proposed algorithm over competing methods.

  4. Assessing the use of food coloring as an appropriate visual guide for homogenously mixed capsule powders in extemporaneous compounding.

    PubMed

    Hoffmann, Brittany; Carlson, Christie; Rao, Deepa A

    2014-01-01

    The purpose of this work was to assess the use of food colors as a visual aid to determine homogeneous mixing in the extemporaneous preparation of capsules. Six different batches of progesterone slow-release 200-mg capsules were prepared by different mixing methods until visually determined as homogeneous based on yellow food coloring distribution in the preparation by the Central Iowa Compounding Pharmacy, Des Moines, Iowa. UV-Vis spectrophotometry was used to extract and evaluate yellow food coloring content in each of these batches and compared to an in-house, small-batch geometric dilution preparation of progesterone slow- release 200-mg capsules. Of the 6 batches tested, only one, which followed the principles of additive dilution and an appropriate mixing time, was both visually and quantitatively homogeneous in the detection of yellow food coloring. The use of food coloring alone is not a valid quality-assurance tool in determining homogeneous mixing. Principles of geometric and/or additive dilution and appropriate mixing times along with the food color can serve as a quality-assurance tool.

  5. Video conference quality assessment based on cooperative sensing of video and audio

    NASA Astrophysics Data System (ADS)

    Wang, Junxi; Chen, Jialin; Tian, Xin; Zhou, Cheng; Zhou, Zheng; Ye, Lu

    2015-12-01

    This paper presents a method to video conference quality assessment, which is based on cooperative sensing of video and audio. In this method, a proposed video quality evaluation method is used to assess the video frame quality. The video frame is divided into noise image and filtered image by the bilateral filters. It is similar to the characteristic of human visual, which could also be seen as a low-pass filtering. The audio frames are evaluated by the PEAQ algorithm. The two results are integrated to evaluate the video conference quality. A video conference database is built to test the performance of the proposed method. It could be found that the objective results correlate well with MOS. Then we can conclude that the proposed method is efficiency in assessing video conference quality.

  6. Blind image quality assessment based on aesthetic and statistical quality-aware features

    NASA Astrophysics Data System (ADS)

    Jenadeleh, Mohsen; Masaeli, Mohammad Masood; Moghaddam, Mohsen Ebrahimi

    2017-07-01

    The main goal of image quality assessment (IQA) methods is the emulation of human perceptual image quality judgments. Therefore, the correlation between objective scores of these methods with human perceptual scores is considered as their performance metric. Human judgment of the image quality implicitly includes many factors when assessing perceptual image qualities such as aesthetics, semantics, context, and various types of visual distortions. The main idea of this paper is to use a host of features that are commonly employed in image aesthetics assessment in order to improve blind image quality assessment (BIQA) methods accuracy. We propose an approach that enriches the features of BIQA methods by integrating a host of aesthetics image features with the features of natural image statistics derived from multiple domains. The proposed features have been used for augmenting five different state-of-the-art BIQA methods, which use statistical natural scene statistics features. Experiments were performed on seven benchmark image quality databases. The experimental results showed significant improvement of the accuracy of the methods.

  7. Questionnaires for Measuring Refractive Surgery Outcomes.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  8. The effect of texture granularity on texture synthesis quality

    NASA Astrophysics Data System (ADS)

    Golestaneh, S. Alireza; Subedar, Mahesh M.; Karam, Lina J.

    2015-09-01

    Natural and artificial textures occur frequently in images and in video sequences. Image/video coding systems based on texture synthesis can make use of a reliable texture synthesis quality assessment method in order to improve the compression performance in terms of perceived quality and bit-rate. Existing objective visual quality assessment methods do not perform satisfactorily when predicting the synthesized texture quality. In our previous work, we showed that texture regularity can be used as an attribute for estimating the quality of synthesized textures. In this paper, we study the effect of another texture attribute, namely texture granularity, on the quality of synthesized textures. For this purpose, subjective studies are conducted to assess the quality of synthesized textures with different levels (low, medium, high) of perceived texture granularity using different types of texture synthesis methods.

  9. Perceived assessment metrics for visible and infrared color fused image quality without reference image

    NASA Astrophysics Data System (ADS)

    Yu, Xuelian; Chen, Qian; Gu, Guohua; Ren, Jianle; Sui, Xiubao

    2015-02-01

    Designing objective quality assessment of color-fused image is a very demanding and challenging task. We propose four no-reference metrics based on human visual system characteristics for objectively evaluating the quality of false color fusion image. The perceived edge metric (PEM) is defined based on visual perception model and color image gradient similarity between the fused image and the source images. The perceptual contrast metric (PCM) is established associating multi-scale contrast and varying contrast sensitivity filter (CSF) with color components. The linear combination of the standard deviation and mean value over the fused image construct the image colorfulness metric (ICM). The color comfort metric (CCM) is designed by the average saturation and the ratio of pixels with high and low saturation. The qualitative and quantitative experimental results demonstrate that the proposed metrics have a good agreement with subjective perception.

  10. Quality of life assessment in ocular toxoplasmosis in a Colombian population.

    PubMed

    de-la-Torre, Alejandra; González-López, Gilberto; Montoya-Gutiérrez, Johanna Milena; Marín-Arango, Viviana; Gómez-Marín, Jorge Enrique

    2011-08-01

    To assess the quality of life in patients with ocular toxoplasmosis. The participants were 29 otherwise healthy patients with retinochoroidal lesions consistent with Toxoplasma infection. The controls were 29 gender and age-matched people with normal visual function who came from the same socioeconomic and educational background as the participants. The authors used the version of the National Eye Institute 25-item visual function questionnaire (NEI VFQ25). Patients with ocular toxoplasmosis had statistically significant lower scores than controls for all the subscales, except for color vision. Patients with bilateral lesions were more affected in the mental health, difficulties role, and specific vision subscales. The median of the compound score for the participants was 79 (range 35-99) and for the controls was 95 (range 72-98). People with ocular toxoplasmosis have worse vision-related quality of life than people without the condition, especially if they have bilateral lesions and more recurrences.

  11. Correlational Analysis of Objective and Subjective Measures of Cataract Quantification.

    PubMed

    Cochener, Béatrice; Patel, Sunni R; Galliot, Florence

    2016-02-01

    To evaluate whether correlations exist between objective and subjective measures of vision quality as a consequence of cataract and whether this may qualify the Objective Scatter Index as a supplementary means of cataract assessment. A prospective multicenter, cross-sectional study was conducted in 10 centers across France in patients undergoing cataract extraction surgery (lens opacity evaluated with the Lens Opacities Classification System III). A quality of life assessment using the Visual Function Index-14 (VF-14) (14 questions scored from 0 to 4) and measurement of visual acuity and evaluation of the Objective Scatter Index (HD Analyzer, Visiometrics SL, Terrassa, Spain) to assess the alteration of light scatter were used as measures in the study. The study included 1,768 eyes of 1,768 patients (mean age: 72.5 years; range: 28 to 93 years). The average OSI score was 4.97 ± 3.13 (range: 0.4 to 20.5). There was good correlation between visual acuity and OSI (r = -0.47, P < .001) and between OSI and VF-14 (r = -0.11, P < .001). The results presented in this study confirm that the Objective Scatter Index has sufficient correlations with visual acuity and VF-14 to supplement existing cataract diagnosis in a large population encompassing a broad spectrum of cataract presentations. Copyright 2016, SLACK Incorporated.

  12. A Spectral Method for Color Quantitation of a Protein Drug Solution.

    PubMed

    Swartz, Trevor E; Yin, Jian; Patapoff, Thomas W; Horst, Travis; Skieresz, Susan M; Leggett, Gordon; Morgan, Charles J; Rahimi, Kimia; Marhoul, Joseph; Kabakoff, Bruce

    2016-01-01

    Color is an important quality attribute for biotherapeutics. In the biotechnology industry, a visual method is most commonly utilized for color characterization of liquid drug protein solutions. The color testing method is used for both batch release and on stability testing for quality control. Using that method, an analyst visually determines the color of the sample by choosing the closest matching European Pharmacopeia reference color solution. The requirement to judge the best match makes it a subjective method. Furthermore, the visual method does not capture data on hue or chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we describe a quantitative method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. Following color industry standards established by International Commission on Illumination, this method converts a protein solution's visible absorption spectra to L*a*b* color space. Color matching is achieved within the L*a*b* color space, a practice that is already widely used in other industries. The work performed here is to facilitate the adoption and transition for the traditional visual assessment method to a quantitative spectral method. We describe here the algorithm used such that the quantitative spectral method correlates with the currently used visual method. In addition, we provide the L*a*b* values for the European Pharmacopeia reference color solutions required for the quantitative method. We have determined these L*a*b* values by gravimetrically preparing and measuring multiple lots of the reference color solutions. We demonstrate that the visual assessment and the quantitative spectral method are comparable using both low- and high-concentration antibody solutions and solutions with varying turbidity. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. The details of the spectral quantitative method are described. A comparison between the visual assessment method and spectral quantitative method is presented. This study supports the transition to a quantitative spectral method from the visual assessment method for quality testing of protein solutions. © PDA, Inc. 2016.

  13. Paediatric x-ray radiation dose reduction and image quality analysis.

    PubMed

    Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H

    2013-09-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.

  14. An analysis of mathematical connection ability based on student learning style on visualization auditory kinesthetic (VAK) learning model with self-assessment

    NASA Astrophysics Data System (ADS)

    Apipah, S.; Kartono; Isnarto

    2018-03-01

    This research aims to analyze the quality of VAK learning with self-assessment toward the ability of mathematical connection performed by students and to analyze students’ mathematical connection ability based on learning styles in VAK learning model with self-assessment. This research applies mixed method type with concurrent embedded design. The subject of this research consists of VIII grade students from State Junior High School 9 Semarang who apply visual learning style, auditory learning style, and kinesthetic learning style. The data of learning style is collected by using questionnaires, the data of mathematical connection ability is collected by performing tests, and the data of self-assessment is collected by using assessment sheets. The quality of learning is qualitatively valued from planning stage, realization stage, and valuation stage. The result of mathematical connection ability test is analyzed quantitatively by mean test, conducting completeness test, mean differentiation test, and mean proportional differentiation test. The result of the research shows that VAK learning model results in well-qualified learning regarded from qualitative and quantitative sides. Students with visual learning style perform the highest mathematical connection ability, students with kinesthetic learning style perform average mathematical connection ability, and students with auditory learning style perform the lowest mathematical connection ability.

  15. Full-reference quality assessment of stereoscopic images by learning binocular receptive field properties.

    PubMed

    Shao, Feng; Li, Kemeng; Lin, Weisi; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2015-10-01

    Quality assessment of 3D images encounters more challenges than its 2D counterparts. Directly applying 2D image quality metrics is not the solution. In this paper, we propose a new full-reference quality assessment for stereoscopic images by learning binocular receptive field properties to be more in line with human visual perception. To be more specific, in the training phase, we learn a multiscale dictionary from the training database, so that the latent structure of images can be represented as a set of basis vectors. In the quality estimation phase, we compute sparse feature similarity index based on the estimated sparse coefficient vectors by considering their phase difference and amplitude difference, and compute global luminance similarity index by considering luminance changes. The final quality score is obtained by incorporating binocular combination based on sparse energy and sparse complexity. Experimental results on five public 3D image quality assessment databases demonstrate that in comparison with the most related existing methods, the devised algorithm achieves high consistency with subjective assessment.

  16. Developing an Interactive Data Visualization Tool to Assess the Impact of Decision Support on Clinical Operations.

    PubMed

    Huber, Timothy C; Krishnaraj, Arun; Monaghan, Dayna; Gaskin, Cree M

    2018-05-18

    Due to mandates from recent legislation, clinical decision support (CDS) software is being adopted by radiology practices across the country. This software provides imaging study decision support for referring providers at the point of order entry. CDS systems produce a large volume of data, providing opportunities for research and quality improvement. In order to better visualize and analyze trends in this data, an interactive data visualization dashboard was created using a commercially available data visualization platform. Following the integration of a commercially available clinical decision support product into the electronic health record, a dashboard was created using a commercially available data visualization platform (Tableau, Seattle, WA). Data generated by the CDS were exported from the data warehouse, where they were stored, into the platform. This allowed for real-time visualization of the data generated by the decision support software. The creation of the dashboard allowed the output from the CDS platform to be more easily analyzed and facilitated hypothesis generation. Integrating data visualization tools into clinical decision support tools allows for easier data analysis and can streamline research and quality improvement efforts.

  17. Automated reference-free detection of motion artifacts in magnetic resonance images.

    PubMed

    Küstner, Thomas; Liebgott, Annika; Mauch, Lukas; Martirosian, Petros; Bamberg, Fabian; Nikolaou, Konstantin; Yang, Bin; Schick, Fritz; Gatidis, Sergios

    2018-04-01

    Our objectives were to provide an automated method for spatially resolved detection and quantification of motion artifacts in MR images of the head and abdomen as well as a quality control of the trained architecture. T1-weighted MR images of the head and the upper abdomen were acquired in 16 healthy volunteers under rest and under motion. Images were divided into overlapping patches of different sizes achieving spatial separation. Using these patches as input data, a convolutional neural network (CNN) was trained to derive probability maps for the presence of motion artifacts. A deep visualization offers a human-interpretable quality control of the trained CNN. Results were visually assessed on probability maps and as classification accuracy on a per-patch, per-slice and per-volunteer basis. On visual assessment, a clear difference of probability maps was observed between data sets with and without motion. The overall accuracy of motion detection on a per-patch/per-volunteer basis reached 97%/100% in the head and 75%/100% in the abdomen, respectively. Automated detection of motion artifacts in MRI is feasible with good accuracy in the head and abdomen. The proposed method provides quantification and localization of artifacts as well as a visualization of the learned content. It may be extended to other anatomic areas and used for quality assurance of MR images.

  18. The Effect of Image Quality, Repeated Study, and Assessment Method on Anatomy Learning

    ERIC Educational Resources Information Center

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A.; Wainman, Bruce C.

    2017-01-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality…

  19. [Survey on avoidable blindness and visual impairment in Panama].

    PubMed

    López, Maritza; Brea, Ileana; Yee, Rita; Yi, Rodolfo; Carles, Víctor; Broce, Alberto; Limburg, Hans; Silva, Juan Carlos

    2014-12-01

    Determine prevalence of blindness and visual impairment in adults aged ≥ 50 years in Panama, identify their main causes, and characterize eye health services. Cross-sectional population study using standard Rapid Assessment of Avoidable Blindness methodology. Fifty people aged ≥ 50 years were selected from each of 84 clusters chosen through representative random sampling of the entire country. Visual acuity was assessed using a Snellen chart; lens and posterior pole status were assessed by direct ophthalmoscopy. Cataract surgery coverage was calculated and its quality assessed, along with causes of visual acuity < 20/60 and barriers to access to surgical treatment. A total of 4 125 people were examined (98.2% of the calculated sample). Age- and sex-adjusted prevalence of blindness was 3.0% (95% CI: 2.3-3.6). The main cause of blindness was cataract (66.4%), followed by glaucoma (10.2%). Cataract (69.2%) was the main cause of severe visual impairment and uncorrected refractive errors were the main cause of moderate visual impairment (60.7%). Surgical cataract coverage in individuals was 76.3%. Of all eyes operated for cataract, 58.0% achieved visual acuity ≤ 20/60 with available correction. Prevalence of blindness in Panama is in line with average prevalence found in other countries of the Region. This problem can be reduced, since 76.2% of cases of blindness and 85.0% of cases of severe visual impairment result from avoidable causes.

  20. Perceived vision-related quality of life and risk of falling among community living elderly people.

    PubMed

    Källstrand-Eriksson, Jeanette; Baigi, Amir; Buer, Nina; Hildingh, Cathrine

    2013-06-01

    Falls and fall injuries among the elderly population are common, since ageing is a risk factor of falling. Today, this is a major problem because the ageing population is increasing. There are predictive factors of falling and visual impairment is one of them. Usually, only visual acuity is considered when measuring visual impairment, and nothing regarding a person's functional visual ability is taken into account. Therefore, the aim of this study was to assess the perceived vision-related quality of life among the community living elderly using the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) and to investigate whether there was any association among vision-related quality of life and falls. There were 212 randomly selected elderly people participating in the study. Our study indicated that the participants had an impaired perceived vision-related health status. General health was the only NEI VFQ-25 variable significantly associated with falls in both men and women. However, among men, near and distance activities, vision-specific social functioning, role difficulties and dependency, color and peripheral vision were related to falls. © 2012 Nordic College of Caring Science.

  1. Protective effect of blue-light shield eyewear for adults against light pollution from self-luminous devices used at night.

    PubMed

    Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo

    2016-01-01

    We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P < 0.05) than with the control eyewear. Sleep efficacy and sleep latency were significantly superior for wearers of the blue-light shield (P < 0.05 for both), and this group reported greater sleepiness during portable device use compared to those using the control eyewear. Participants rated the blue-light shield as providing acceptable visual quality.

  2. An integrated bioinformatics approach to improve two-color microarray quality-control: impact on biological conclusions.

    PubMed

    van Haaften, Rachel I M; Luceri, Cristina; van Erk, Arie; Evelo, Chris T A

    2009-06-01

    Omics technology used for large-scale measurements of gene expression is rapidly evolving. This work pointed out the need of an extensive bioinformatics analyses for array quality assessment before and after gene expression clustering and pathway analysis. A study focused on the effect of red wine polyphenols on rat colon mucosa was used to test the impact of quality control and normalisation steps on the biological conclusions. The integration of data visualization, pathway analysis and clustering revealed an artifact problem that was solved with an adapted normalisation. We propose a possible point to point standard analysis procedure, based on a combination of clustering and data visualization for the analysis of microarray data.

  3. Interaction of aberrations, diffraction, and quantal fluctuations determine the impact of pupil size on visual quality.

    PubMed

    Xu, Renfeng; Wang, Huachun; Thibos, Larry N; Bradley, Arthur

    2017-04-01

    Our purpose is to develop a computational approach that jointly assesses the impact of stimulus luminance and pupil size on visual quality. We compared traditional optical measures of image quality and those that incorporate the impact of retinal illuminance dependent neural contrast sensitivity. Visually weighted image quality was calculated for a presbyopic model eye with representative levels of chromatic and monochromatic aberrations as pupil diameter was varied from 7 to 1 mm, stimulus luminance varied from 2000 to 0.1  cd/m2, and defocus varied from 0 to -2 diopters. The model included the effects of quantal fluctuations on neural contrast sensitivity. We tested the model's predictions for five cycles per degree gratings by measuring contrast sensitivity at 5  cyc/deg. Unlike the traditional Strehl ratio and the visually weighted area under the modulation transfer function, the visual Strehl ratio derived from the optical transfer function was able to capture the combined impact of optics and quantal noise on visual quality. In a well-focused eye, provided retinal illuminance is held constant as pupil size varies, visual image quality scales approximately as the square root of illuminance because of quantum fluctuations, but optimum pupil size is essentially independent of retinal illuminance and quantum fluctuations. Conversely, when stimulus luminance is held constant (and therefore illuminance varies with pupil size), optimum pupil size increases as luminance decreases, thereby compensating partially for increased quantum fluctuations. However, in the presence of -1 and -2 diopters of defocus and at high photopic levels where Weber's law operates, optical aberrations and diffraction dominate image quality and pupil optimization. Similar behavior was observed in human observers viewing sinusoidal gratings. Optimum pupil size increases as stimulus luminance drops for the well-focused eye, and the benefits of small pupils for improving defocused image quality remain throughout the photopic and mesopic ranges. However, restricting pupils to <2  mm will cause significant reductions in the best focus vision at low photopic and mesopic luminances.

  4. Assessment of cataract surgical outcomes in settings where follow-up is poor: PRECOG, a multicentre observational study.

    PubMed

    Congdon, Nathan; Yan, Xixi; Lansingh, Van; Sisay, Alemayehu; Müller, Andreas; Chan, Ving; Jin, Ling; Meltzer, Mirjam E; Karumanchi, Sasipriya M; Guan, Chunhong; Vuong, Quy; Rivera, Nelson; McCleod-Omawale, Joan; He, Mingguang

    2013-07-01

    Poor follow-up after cataract surgery in developing countries makes assessment of operative quality uncertain. We aimed to assess two strategies to measure visual outcome: recording the visual acuity of all patients 3 or fewer days postoperatively (early postoperative assessment), and recording that of only those patients who returned for the final follow-up examination after 40 or more days without additional prompting. Each of 40 centres in ten countries in Asia, Africa, and Latin America recruited 40-120 consecutive surgical cataract patients. Operative-eye best-corrected visual acuity and uncorrected visual acuity were recorded before surgery, 3 or fewer days postoperatively, and 40 or more days postoperatively. Clinics logged whether each patient had returned for the final follow-up examination without additional prompting, had to be actively encouraged to return, or had to be examined at home. Visual outcome for each centre was defined as the proportion of patients with uncorrected visual acuity of 6/18 or better minus the proportion with uncorrected visual acuity of 6/60 or worse, and was calculated for each participating hospital with results from the early assessment of all patients and the late assessment of only those returning unprompted, with results from the final follow-up assessment for all patients used as the standard. Of 3708 participants, 3441 (93%) had final follow-up vision data recorded 40 or more days after surgery, 1831 of whom (51% of the 3581 total participants for whom mode of follow-up was recorded) had returned to the clinic without additional prompting. Visual outcome by hospital from early postoperative and final follow-up assessment for all patients were highly correlated (Spearman's rs=0·74, p<0·0001). Visual outcome from final follow-up assessment for all patients and for only those who returned without additional prompting were also highly correlated (rs=0·86, p<0·0001), even for the 17 hospitals with unprompted return rates of less than 50% (rs=0·71, p=0·002). When we divided hospitals into top 25%, middle 50%, and bottom 25% by visual outcome, classification based on final follow-up assessment for all patients was the same as that based on early postoperative assessment for 27 (68%) of 40 centres, and the same as that based on data from patients who returned without additional prompting in 31 (84%) of 37 centres. Use of glasses to optimise vision at the time of the early and late examinations did not further improve the correlations. Early vision assessment for all patients and follow-up assessment only for patients who return to the clinic without prompting are valid measures of operative quality in settings where follow-up is poor. ORBIS International, Fred Hollows Foundation, Helen Keller International, International Association for the Prevention of Blindness Latin American Office, Aravind Eye Care System. Copyright © 2013 Congdon et al. Open Access article distributed under the terms of CC BY. Published by .. All rights reserved.

  5. Landscape character assessment with GIS using map-based indicators and photographs in the relationship between landscape and roads.

    PubMed

    Martín, Belén; Ortega, Emilio; Otero, Isabel; Arce, Rosa M

    2016-09-15

    Planning and monitoring of landscapes cannot be reduced to its outstanding features, but must take into account all its characteristics. In this context, the relationship of landscape with roads is of particular importance, because roads alter the territory's environmental resources but also constitute a resource through which the individual comes into contact with the landscape. The aim of this work is to design a methodology to evaluate both the character and the scenic quality of the landscape as viewed from motorways and to provide measures to assess whether the motorway conveys the character of the landscape of which it forms part. The main contribution of this research consists of assessing landscape character through a novel series of map-based indicators and combining the findings with a photo-based method of assessing visual landscape quality. The method has been applied to a case study around a motorway in Madrid Region (Spain). Landscape character values regarding coherence, complexity, naturalness, visual scale, disturbance, historicity, and ephemera are obtained using Geographic Information Systems. Additionally, the landscape quality results derived using photographs allow the incorporation of the user's perception at a local scale. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Icarus: visualizer for de novo assembly evaluation.

    PubMed

    Mikheenko, Alla; Valin, Gleb; Prjibelski, Andrey; Saveliev, Vladislav; Gurevich, Alexey

    2016-11-01

    : Data visualization plays an increasingly important role in NGS data analysis. With advances in both sequencing and computational technologies, it has become a new bottleneck in genomics studies. Indeed, evaluation of de novo genome assemblies is one of the areas that can benefit from the visualization. However, even though multiple quality assessment methods are now available, existing visualization tools are hardly suitable for this purpose. Here, we present Icarus-a novel genome visualizer for accurate assessment and analysis of genomic draft assemblies, which is based on the tool QUAST. Icarus can be used in studies where a related reference genome is available, as well as for non-model organisms. The tool is available online and as a standalone application. http://cab.spbu.ru/software/icarus CONTACT: aleksey.gurevich@spbu.ruSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Efficacy of model-based iterative reconstruction technique in non-enhanced CT of the renal tracts for ureteric calculi.

    PubMed

    Tan, T J; Lau, Kenneth K; Jackson, Dana; Ardley, Nicholas; Borasu, Adina

    2017-04-01

    The purpose of this study was to assess the efficacy of model-based iterative reconstruction (MBIR), statistical iterative reconstruction (SIR), and filtered back projection (FBP) image reconstruction algorithms in the delineation of ureters and overall image quality on non-enhanced computed tomography of the renal tracts (NECT-KUB). This was a prospective study of 40 adult patients who underwent NECT-KUB for investigation of ureteric colic. Images were reconstructed using FBP, SIR, and MBIR techniques and individually and randomly assessed by two blinded radiologists. Parameters measured were overall image quality, presence of ureteric calculus, presence of hydronephrosis or hydroureters, image quality of each ureteric segment, total length of ureters unable to be visualized, attenuation values of image noise, and retroperitoneal fat content for each patient. There were no diagnostic discrepancies between image reconstruction modalities for urolithiasis. Overall image qualities and for each ureteric segment were superior using MBIR (67.5 % rated as 'Good to Excellent' vs. 25 % in SIR and 2.5 % in FBP). The lengths of non-visualized ureteric segments were shortest using MBIR (55.0 % measured 'less than 5 cm' vs. ASIR 33.8 % and FBP 10 %). MBIR was able to reduce overall image noise by up to 49.36 % over SIR and 71.02 % over FBP. MBIR technique improves overall image quality and visualization of ureters over FBP and SIR.

  8. Chapter 3:Sorting red maple logs for structural quality

    Treesearch

    Xiping Wang

    2005-01-01

    Nondestructive evaluation (NDE) of wood materials has a long history of application in the wood products industry. Visual grading of lumber is perhaps one of the earliest NDE forms. Visual assessment of a piece of lumber requires the grader to estimate a strength ratio on the basis of observed external defects (USDA 1999). The ratio is used to estimate the strength of...

  9. Some lessons learned in three years with ADS-33C. [rotorcraft handling qualities specification

    NASA Technical Reports Server (NTRS)

    Key, David L.; Blanken, Chris L.; Hoh, Roger H.

    1993-01-01

    Three years of using the U.S. Army's rotorcraft handling qualities specification, Aeronautical Design Standard - 33, has shown it to be surprisingly robust. It appears to provide an excellent basis for design and for assessment, however, as the subtleties become more well understood, several areas needing refinement became apparent. Three responses to these needs have been documented in this paper: (1) The yaw-axis attitude quickness for hover target acquisition and tracking can be relaxed slightly. (2) Understanding and application of criteria for degraded visual environments needed elaboration. This and some guidelines for testing to obtain visual cue ratings have been documented. (3) The flight test maneuvers were an innovation that turned out to be very valuable. Their extensive use has made it necessary to tighten definitions and testing guidance. This was accomplished for a good visual environment and is underway for degraded visual environments.

  10. Evaluation of an organic light-emitting diode display for precise visual stimulation.

    PubMed

    Ito, Hiroyuki; Ogawa, Masaki; Sunaga, Shoji

    2013-06-11

    A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatial uniformity, color gamut, and contrast ratio. Changes in the intensity of luminance were sharper on the OLED display than those on a liquid crystal display. Therefore, such OLED displays could replace conventional cathode ray tube displays in vision research for high quality stimulus presentation. Benefits of using OLED displays in vision research were especially apparent in the fields of low-level vision, where precise control and description of the stimulus are needed, e.g., in mesopic or scotopic vision, color vision, and motion perception.

  11. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment

    PubMed Central

    Lee, Christine; Tu, Hong Anh; Weir, Mark; Holubowich, Corinne

    2016-01-01

    Background Retinitis pigmentosa is a group of genetic disorders that involves the breakdown and loss of photoreceptors in the retina, resulting in progressive retinal degeneration and eventual blindness. The Argus II Retinal Prosthesis System is the only currently available surgical implantable device approved by Health Canada. It has been shown to improve visual function in patients with severe visual loss from advanced retinitis pigmentosa. The objective of this analysis was to examine the clinical effectiveness, cost-effectiveness, budget impact, and safety of the Argus II system in improving visual function, as well as exploring patient experiences with the system. Methods We performed a systematic search of the literature for studies examining the effects of the Argus II retinal prosthesis system in patients with advanced retinitis pigmentosa, and appraised the evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria, focusing on visual function, functional outcomes, quality of life, and adverse events. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care over a 10-year time horizon. We also conducted a 5-year budget impact analysis. We used a qualitative design and an interview methodology to examine patients’ lived experience, and we used a modified grounded theory methodology to analyze information from interviews. Transcripts were coded, and themes were compared against one another. Results One multicentre international study and one single-centre study were included in the clinical review. In both studies, patients showed improved visual function with the Argus II system. However, the sight-threatening surgical complication rate was substantial. In the base-case analysis, the Argus II system was cost-effective compared with standard care only if willingness-to-pay was more than $207,616 per quality-adjusted life-year. The 5-year budget impact of funding the Argus II system ranged from $800,404 to $837,596. Retinitis pigmentosa significantly affects people's ability to navigate physical and virtual environments. Argus II was described as enabling the fundamental elements of sight. As such, it had a positive impact on quality of life for people with retinitis pigmentosa. Conclusions Based on evidence of moderate quality, patients with advanced retinitis pigmentosa who were implanted with the Argus II retinal prosthesis system showed significant improvement in visual function, real-life functional outcomes, and quality of life, but there were complications associated with the surgery that could be managed through standard ophthalmologic treatments. The costs for the technology are high. PMID:27468325

  12. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment.

    PubMed

    2016-01-01

    Retinitis pigmentosa is a group of genetic disorders that involves the breakdown and loss of photoreceptors in the retina, resulting in progressive retinal degeneration and eventual blindness. The Argus II Retinal Prosthesis System is the only currently available surgical implantable device approved by Health Canada. It has been shown to improve visual function in patients with severe visual loss from advanced retinitis pigmentosa. The objective of this analysis was to examine the clinical effectiveness, cost-effectiveness, budget impact, and safety of the Argus II system in improving visual function, as well as exploring patient experiences with the system. We performed a systematic search of the literature for studies examining the effects of the Argus II retinal prosthesis system in patients with advanced retinitis pigmentosa, and appraised the evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria, focusing on visual function, functional outcomes, quality of life, and adverse events. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care over a 10-year time horizon. We also conducted a 5-year budget impact analysis. We used a qualitative design and an interview methodology to examine patients' lived experience, and we used a modified grounded theory methodology to analyze information from interviews. Transcripts were coded, and themes were compared against one another. One multicentre international study and one single-centre study were included in the clinical review. In both studies, patients showed improved visual function with the Argus II system. However, the sight-threatening surgical complication rate was substantial. In the base-case analysis, the Argus II system was cost-effective compared with standard care only if willingness-to-pay was more than $207,616 per quality-adjusted life-year. The 5-year budget impact of funding the Argus II system ranged from $800,404 to $837,596. Retinitis pigmentosa significantly affects people's ability to navigate physical and virtual environments. Argus II was described as enabling the fundamental elements of sight. As such, it had a positive impact on quality of life for people with retinitis pigmentosa. Based on evidence of moderate quality, patients with advanced retinitis pigmentosa who were implanted with the Argus II retinal prosthesis system showed significant improvement in visual function, real-life functional outcomes, and quality of life, but there were complications associated with the surgery that could be managed through standard ophthalmologic treatments. The costs for the technology are high.

  13. 2D AND 3D KINEMATICS DURING LATERAL STEP-DOWN TESTING IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    PubMed

    Mostaed, Maria F; Werner, David M; Barrios, Joaquin A

    2018-02-01

    The lateral step-down test is an established clinical evaluation tool to assess quality of movement in patients with knee disorders. However, this test has not been investigated in individuals after anterior cruciate ligament reconstruction (ACLR) in association with quantitative 3D motion analysis. The purpose of this study was to determine the strength of association between visually-assessed quality of movement during the lateral step-down test and 3D lower limb kinematics in patients with history of ACLR. A second purpose was to compare kinematics between subgroups based on the presence or absence of faulty alignments during the task. The final purpose was to compare visually-assessed quality of movement scores between box heights during lateral step-down testing. Twenty subjects at least one year status post-ACLR (18 females, age of 24.5 ± 4.6 years and body mass index of 23.4 ± 2.3 kg/m 2 ) performed the lateral step-down test unilaterally on the surgical limb atop four and six inch boxes. A board-certified orthopedic physical therapist scored overall quality of movement during the lateral step-down test using established criteria during 2D video playback. Lower limb kinematics were simultaneously collected using 3D motion capture. An alpha level of 0.05 was used for all statistical treatments. Overall 2D quality of movement score significantly correlated (r =0.47-0.57) with 3D hip adduction and hip internal rotation across box heights. Across box heights, the presence of faulty pelvic alignment differentiated a subgroup exhibiting less peak knee flexion, and the presence of faulty knee alignment differentiated a subgroup exhibiting greater peak hip adduction. The six inch box elicited worse quality of movement compared to the four inch box. These results suggest that visually-assessed quality of movement is associated with several kinematic variables after ACLR. 2D movement deviations at the pelvis appear to consistently relate to less knee flexion, and 2D deviations at the knee appear to suggest greater hip adduction. Generally, poorer quality of movement was observed for the six inch box height. Clinically, these data suggest that interventions targeting hip abductor and knee extensor strength and neuromuscular control may be useful in the presence of poor quality of movement during lateral step-down testing. 2b.

  14. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    PubMed

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. The efficacy of VIPP-V parenting training for parents of young children with a visual or visual-and-intellectual disability: a randomized controlled trial.

    PubMed

    Platje, Evelien; Sterkenburg, Paula; Overbeek, Mathile; Kef, Sabina; Schuengel, Carlo

    2018-01-23

    Video-feedback Intervention to promote positive parenting-visual (VIPP-V) or visual-and-intellectual disability is an attachment-based intervention aimed at enhancing sensitive parenting and promoting positive parent-child relationships. A randomized controlled trial was conducted to assess the efficacy of VIPP-V for parents of children aged 1-5 with visual or visual-and-intellectual disabilities. A total of 37 dyads received only care-as-usual (CAU) and 40 received VIPP-V besides CAU. The parents receiving VIPP-V did not show increased parental sensitivity or parent-child interaction quality, however, their parenting self-efficacy increased. Moreover, the increase in parental self-efficacy predicted the increase in parent-child interaction. In conclusion, VIPP-V does not appear to directly improve the quality of contact between parent and child, but does contribute to the self-efficacy of parents to support and to comfort their child. Moreover, as parents experience their parenting as more positive, this may eventually lead to higher sensitive responsiveness and more positive parent-child interactions.

  16. Use of invisible near infrared light fluorescence with indocyanine green and methylene blue in urology. Part 2.

    PubMed

    Polom, Wojciech; Markuszewski, Marcin; Rho, Young Soo; Matuszewski, Marcin

    2014-01-01

    In the second part of this paper, concerning the use of invisible near infrared light (NIR) fluorescence with indocyanine green (ICG) and methylene blue (MB) in urology, other possible uses of this new technique will be presented. In kidney transplantation, this concerns allograft perfusion and real time NIR-guided angiography; moreover, perfusion angiography of tissue flaps, NIRF visualization of ureters, NIR-guided visualization of urinary calcifications, NIRF in male infertility and semen quality assessment. In this part, we have also analysed cancer targeting and imaging fluorophores as well as cost benefits associated with the use of these new techniques. PubMed and Medline databases were searched for ICG and MB use in urological settings, along with data published in abstracts of urological conferences. Although NIR-guided ICG and MB are still in their initial phases, there have been significant developments in a few more major domains of urology, including 1) kidney transplantation: kidney allograft perfusion and vessel reconstruction; 2) angiography perfusion of tissue flaps; 3) visualization of ureters; 4) visualization of urinary calcifications; and 5) NIRF in male infertility and semen quality assessment. Near infrared technology in urology is at its early stages. More studies are needed to assess the true potential and limitations of the technology. Initial studies show that this pioneering tool may influence various aspects of urology.

  17. Clinical and Psychometric Evaluations of the Cerebral Vision Screening Questionnaire in 461 Nonaphasic Individuals Poststroke.

    PubMed

    Neumann, Guenter; Schaadt, Anna-Katharina; Reinhart, Stefan; Kerkhoff, Georg

    2016-03-01

    Cerebral vision disorders (CVDs) are frequent after brain damage and impair the patient's outcome. Yet clinically and psychometrically validated procedures for the anamnesis of CVD are lacking. To evaluate the clinical validity and psychometric qualities of the Cerebral Vision Screening Questionnaire (CVSQ) for the anamnesis of CVD in individuals poststroke. Analysis of the patients' subjective visual complaints in the 10-item CVSQ in relation to objective visual perimetry, tests of reading, visual scanning, visual acuity, spatial contrast sensitivity, light/dark adaptation, and visual depth judgments. Psychometric analyses of concurrent validity, specificity, sensitivity, positive/negative predictive value, and interrater reliability were also done. Four hundred sixty-one patients with unilateral (39.5% left, 47.5% right) or bilateral stroke (13.0%) were included. Most patients were assessed in the chronic stage, on average 36.7 (range = 1-620) weeks poststroke. The majority of all patients (96.4%) recognized their visual symptoms within 1 week poststroke when asked for specifically. Mean concurrent validity of the CVSQ with objective tests was 0.64 (0.54-0.79, P < .05). The mean positive predictive value was 80.1%, mean negative predictive value 82.9%, mean specificity 81.7%, and mean sensitivity 79.8%. The mean interrater reliability was 0.76 for a 1-week interval between both assessments (all P < .05). The CVSQ is suitable for the anamnesis of CVD poststroke because of its brevity (10 minute), clinical validity, and good psychometric qualities. It, thus, improves neurovisual diagnosis and guides the clinician in the selection of necessary assessments and appropriate neurovisual therapies for the patient. © The Author(s) 2015.

  18. Prevalence and causes of visual impairment and blindness, cataract surgical coverage and outcomes of cataract surgery in Libya.

    PubMed

    Rabiu, Muhammad Mansur; Jenf, Mansour; Fituri, Suad; Choudhury, Abdulhanan; Agbabiaka, Idris; Mousa, Ahmed

    2013-01-01

    To assess the major causes of avoidable blindness, and outcomes and barriers to cataract services in Libya. A stratified multistage cluster random sample study was conducted in the four regions of Libya. Visual acuity and lens assessment were performed on all subjects. Those with presenting visual acuity <6/18 in either or both eyes were further investigated to determine cause(s) of impairment. Barriers to cataract surgery were investigated. Visual outcomes of subjects with surgery performed were assessed. A total of 8538 persons aged ≥50 years were examined across the four regions. The prevalence of blindness was 3.25% (3.15% with best correction), which varied across the regions (2.94-3.80%); after adjustment for age and sex, the prevalence was 2.66%. Major causes of blindness were cataract (29%), glaucoma (24%) and other corneal scars (14%). Causes were similar across all regions except in the south. Avoidable causes were responsible for 60.6% of blindness. Major causes of visual impairment were cataract (31.2%), diabetic retinopathy (16.6%) and posterior segment diseases (15.1%). Cataract surgical coverage among those with visual acuity <3/60 was 95.4%, with no sex differences. About 38% of cataract-operated eyes had poor outcome even after best correction (35%). There was poor outcome in 33% of pseudophakic eyes with best correction. The major barriers to service uptake were "waiting for maturity" (26%), "unaware of treatment" (24%) and "God's will/destiny" (17%). Libya needs to improve the quality of cataract surgery across all the regions. The southern region needs improvement in both quality and coverage of services.

  19. Quality of Life Assessment.

    ERIC Educational Resources Information Center

    Gore, Peter H.

    Explaining the use of overlay methodology in the assessment of rural social service this paper describes a technique of visual juxtaposition wherein information is matched with geographic location. To ascertain whether senior citizen centers are located in areas of client concentration, for example, this model superimposes the location of senior…

  20. A Survey of Educational Uses of Molecular Visualization Freeware†

    PubMed Central

    Craig, Paul A.; Michel, Lea Vacca; Bateman, Robert C.

    2014-01-01

    As biochemists, one of our most captivating teaching tools is the use of molecular visualization. It is a compelling medium that can be used to communicate structural information much more effectively with interactive animations than with static figures. We have conducted a survey to begin a systematic evaluation of the current classroom usage of molecular visualization. Participants (n = 116) were asked to complete 11 multiple choice and 3 open ended questions. To provide more depth to these results, interviews were conducted with 12 of the participants. Many common themes arose in the survey and the interviews: a shared passion for the use of molecular visualization in teaching, broad diversity in software preference, the lack of uniform standards for assessment, a desire for more quality resources, and the challenge of enabling students to incorporate visualization in their learning. The majority of respondents had used molecular visualization for more than 5 years and mentioned 32 different visualization tools used, with Jmol and PyMOL clearly standing out as the most frequently used programs at the present time. The most common uses of molecular visualization in teaching were lecture and lab illustrations, followed by exam questions, in-class or in-laboratory exercises, and student projects, which frequently included presentations. While a minority of instructors used a grading rubric/scoring matrix for assessment of student learning with molecular visualization, many expressed a desire for common use assessment tools. PMID:23649886

  1. Perceived visual informativeness (PVI): construct and scale development to assess visual information in printed materials.

    PubMed

    King, Andy J; Jensen, Jakob D; Davis, LaShara A; Carcioppolo, Nick

    2014-01-01

    There is a paucity of research on the visual images used in health communication messages and campaign materials. Even though many studies suggest further investigation of these visual messages and their features, few studies provide specific constructs or assessment tools for evaluating the characteristics of visual messages in health communication contexts. The authors conducted 2 studies to validate a measure of perceived visual informativeness (PVI), a message construct assessing visual messages presenting statistical or indexical information. In Study 1, a 7-item scale was created that demonstrated good internal reliability (α = .91), as well as convergent and divergent validity with related message constructs such as perceived message quality, perceived informativeness, and perceived attractiveness. PVI also converged with a preference for visual learning but was unrelated to a person's actual vision ability. In addition, PVI exhibited concurrent validity with a number of important constructs including perceived message effectiveness, decisional satisfaction, and three key public health theory behavior predictors: perceived benefits, perceived barriers, and self-efficacy. Study 2 provided more evidence that PVI is an internally reliable measure and demonstrates that PVI is a modifiable message feature that can be tested in future experimental work. PVI provides an initial step to assist in the evaluation and testing of visual messages in campaign and intervention materials promoting informed decision making and behavior change.

  2. Quality of life of glaucoma patients in China: sociodemographic, clinical, and psychological correlates-a cross-sectional study.

    PubMed

    Zhou, Chuandi; Qian, Shaohong; Wu, Peixia; Qiu, Chen

    2014-04-01

    To assess vision-related quality of life (VRQoL) in Chinese glaucoma patients and explore its sociodemographic, clinical and psychological correlates, and determine which of them explain the largest variation. This cross-sectional study included 508 Chinese glaucoma patients. Chinese-version Glaucoma Quality of Life-15 questionnaire (CHI-GQL-15) and Hospital Anxiety and Depression Scales were administered to all participants to evaluate their VRQoL and psychological distresses. Visual functions (habitual-corrected visual acuity (HCVA), intraocular pressure, and mean defect (MD) of visual field) were assessed through clinical examinations by professionals. Sociodemographic information and other treatment histories were collected via interviews and chart review. Stepwise multiple linear regression analyses were performed to identify sociodemographic, clinical, and psychological predictors of VRQoL. The mean summary score for CHI-GQL-15 was 28.79 ± 12.74. Patients exhibited the greatest difficulty in activities involving glare and dark adaptation (28.19 ± 22.86), followed by central and near vision (26.18 ± 26.56), peripheral vision (18.03 ± 21.37), and the least difficulty for outdoor mobility (15.06 ± 24.57). Moderate and heavy economic burden, HCVA and MD of both the better and the worse eyes, number of glaucoma surgeries in the treatment history and the presence of depression were independent predictors for VRQoL of glaucoma patients. Clinical factors explained the largest variation. VRQoL of glaucoma patients is multifactorial and was primarily determined by clinical indices. VRQoL assessment could be informative when adopted as a complement to objective visual measures in clinical practice.

  3. NMF-Based Image Quality Assessment Using Extreme Learning Machine.

    PubMed

    Wang, Shuigen; Deng, Chenwei; Lin, Weisi; Huang, Guang-Bin; Zhao, Baojun

    2017-01-01

    Numerous state-of-the-art perceptual image quality assessment (IQA) algorithms share a common two-stage process: distortion description followed by distortion effects pooling. As for the first stage, the distortion descriptors or measurements are expected to be effective representatives of human visual variations, while the second stage should well express the relationship among quality descriptors and the perceptual visual quality. However, most of the existing quality descriptors (e.g., luminance, contrast, and gradient) do not seem to be consistent with human perception, and the effects pooling is often done in ad-hoc ways. In this paper, we propose a novel full-reference IQA metric. It applies non-negative matrix factorization (NMF) to measure image degradations by making use of the parts-based representation of NMF. On the other hand, a new machine learning technique [extreme learning machine (ELM)] is employed to address the limitations of the existing pooling techniques. Compared with neural networks and support vector regression, ELM can achieve higher learning accuracy with faster learning speed. Extensive experimental results demonstrate that the proposed metric has better performance and lower computational complexity in comparison with the relevant state-of-the-art approaches.

  4. The use of a Stream Visual Assessment Protocol to determine ecosystem integrity in an urban watershed in Puerto Rico

    NASA Astrophysics Data System (ADS)

    de Jesús-Crespo, Rebeca; Ramirez, Alonso

    The growing need to protect stream ecosystems in Puerto Rico requires the development of monitoring procedures that help determine management priorities. Physical habitat assessments have been used to make quick evaluations that are cost efficient and easy conduct, yet they need to be studied further to understand their accuracy at predicting stream health. This study evaluated the efficiency of the Hawaii Stream Visual Assessment Protocol (HSVAP) at determining integrity of streams within the highly urbanized Rio Piedras watershed in Puerto Rico. To validate the protocol we compared results from HSVAP assessments conducted at 16 reaches with water quality and macroinvertebrate data collected at the same sites. Results from linear regressions between the water quality measures and HSVAP scores showed that there was no significant relationships ( R2 = 0.48; p = 0.08). This implies that the protocol is not supported by the water quality data. However, results from regressions between macroinvertebrate diversity and the number of families per site showed a significant positive relation with HSVAP scores ( R2 = 0.30; p = 0.02; R2 = 0.24; p = 0.05). In addition, a significant negative relation was observed between HSVAP scores and the Family Biotic Index (FBI) ( R2 = 0.32; p = 0.02). Comparisons between ratings obtained from the FBI and HSVAP scores suggest that the HSVAP classified sites as having higher quality than the biological metric. Based on these results, it can be concluded that the HSVAP is a good tool for a general assessment of the physical characteristics of a stream, but it needs modifications to accurately assess ecological quality of streams in Puerto Rico.

  5. Standardizing evaluation of pQCT image quality in the presence of subject movement: qualitative versus quantitative assessment.

    PubMed

    Blew, Robert M; Lee, Vinson R; Farr, Joshua N; Schiferl, Daniel J; Going, Scott B

    2014-02-01

    Peripheral quantitative computed tomography (pQCT) is an essential tool for assessing bone parameters of the limbs, but subject movement and its impact on image quality remains a challenge to manage. The current approach to determine image viability is by visual inspection, but pQCT lacks a quantitative evaluation. Therefore, the aims of this study were to (1) examine the reliability of a qualitative visual inspection scale and (2) establish a quantitative motion assessment methodology. Scans were performed on 506 healthy girls (9-13 years) at diaphyseal regions of the femur and tibia. Scans were rated for movement independently by three technicians using a linear, nominal scale. Quantitatively, a ratio of movement to limb size (%Move) provided a measure of movement artifact. A repeat-scan subsample (n = 46) was examined to determine %Move's impact on bone parameters. Agreement between measurers was strong (intraclass correlation coefficient = 0.732 for tibia, 0.812 for femur), but greater variability was observed in scans rated 3 or 4, the delineation between repeat and no repeat. The quantitative approach found ≥95% of subjects had %Move <25 %. Comparison of initial and repeat scans by groups above and below 25% initial movement showed significant differences in the >25 % grouping. A pQCT visual inspection scale can be a reliable metric of image quality, but technicians may periodically mischaracterize subject motion. The presented quantitative methodology yields more consistent movement assessment and could unify procedure across laboratories. Data suggest a delineation of 25% movement for determining whether a diaphyseal scan is viable or requires repeat.

  6. Standardizing Evaluation of pQCT Image Quality in the Presence of Subject Movement: Qualitative vs. Quantitative Assessment

    PubMed Central

    Blew, Robert M.; Lee, Vinson R.; Farr, Joshua N.; Schiferl, Daniel J.; Going, Scott B.

    2013-01-01

    Purpose Peripheral quantitative computed tomography (pQCT) is an essential tool for assessing bone parameters of the limbs, but subject movement and its impact on image quality remains a challenge to manage. The current approach to determine image viability is by visual inspection, but pQCT lacks a quantitative evaluation. Therefore, the aims of this study were to (1) examine the reliability of a qualitative visual inspection scale, and (2) establish a quantitative motion assessment methodology. Methods Scans were performed on 506 healthy girls (9–13yr) at diaphyseal regions of the femur and tibia. Scans were rated for movement independently by three technicians using a linear, nominal scale. Quantitatively, a ratio of movement to limb size (%Move) provided a measure of movement artifact. A repeat-scan subsample (n=46) was examined to determine %Move’s impact on bone parameters. Results Agreement between measurers was strong (ICC = .732 for tibia, .812 for femur), but greater variability was observed in scans rated 3 or 4, the delineation between repeat or no repeat. The quantitative approach found ≥95% of subjects had %Move <25%. Comparison of initial and repeat scans by groups above and below 25% initial movement, showed significant differences in the >25% grouping. Conclusions A pQCT visual inspection scale can be a reliable metric of image quality but technicians may periodically mischaracterize subject motion. The presented quantitative methodology yields more consistent movement assessment and could unify procedure across laboratories. Data suggest a delineation of 25% movement for determining whether a diaphyseal scan is viable or requires repeat. PMID:24077875

  7. Prostate seed implant quality assessment using MR and CT image fusion.

    PubMed

    Amdur, R J; Gladstone, D; Leopold, K A; Harris, R D

    1999-01-01

    After a seed implant of the prostate, computerized tomography (CT) is ideal for determining seed distribution but soft tissue anatomy is frequently not well visualized. Magnetic resonance (MR) images soft tissue anatomy well but seed visualization is problematic. We describe a method of fusing CT and MR images to exploit the advantages of both of these modalities when assessing the quality of a prostate seed implant. Eleven consecutive prostate seed implant patients were imaged with axial MR and CT scans. MR and CT images were fused in three dimensions using the Pinnacle 3.0 version of the ADAC treatment planning system. The urethra and bladder base were used to "line up" MR and CT image sets during image fusion. Alignment was accomplished using translation and rotation in the three ortho-normal planes. Accuracy of image fusion was evaluated by calculating the maximum deviation in millimeters between the center of the urethra on axial MR versus CT images. Implant quality was determined by comparing dosimetric results to previously set parameters. Image fusion was performed with a high degree of accuracy. When lining up the urethra and base of bladder, the maximum difference in axial position of the urethra between MR and CT averaged 2.5 mm (range 1.3-4.0 mm, SD 0.9 mm). By projecting CT-derived dose distributions over MR images of soft tissue structures, qualitative and quantitative evaluation of implant quality is straightforward. The image-fusion process we describe provides a sophisticated way of assessing the quality of a prostate seed implant. Commercial software makes the process time-efficient and available to any clinical practice with a high-quality treatment planning system. While we use MR to image soft tissue structures, the process could be used with any imaging modality that is able to visualize the prostatic urethra (e.g., ultrasound).

  8. MASQOT: a method for cDNA microarray spot quality control

    PubMed Central

    Bylesjö, Max; Eriksson, Daniel; Sjödin, Andreas; Sjöström, Michael; Jansson, Stefan; Antti, Henrik; Trygg, Johan

    2005-01-01

    Background cDNA microarray technology has emerged as a major player in the parallel detection of biomolecules, but still suffers from fundamental technical problems. Identifying and removing unreliable data is crucial to prevent the risk of receiving illusive analysis results. Visual assessment of spot quality is still a common procedure, despite the time-consuming work of manually inspecting spots in the range of hundreds of thousands or more. Results A novel methodology for cDNA microarray spot quality control is outlined. Multivariate discriminant analysis was used to assess spot quality based on existing and novel descriptors. The presented methodology displays high reproducibility and was found superior in identifying unreliable data compared to other evaluated methodologies. Conclusion The proposed methodology for cDNA microarray spot quality control generates non-discrete values of spot quality which can be utilized as weights in subsequent analysis procedures as well as to discard spots of undesired quality using the suggested threshold values. The MASQOT approach provides a consistent assessment of spot quality and can be considered an alternative to the labor-intensive manual quality assessment process. PMID:16223442

  9. Blind image quality assessment via probabilistic latent semantic analysis.

    PubMed

    Yang, Xichen; Sun, Quansen; Wang, Tianshu

    2016-01-01

    We propose a blind image quality assessment that is highly unsupervised and training free. The new method is based on the hypothesis that the effect caused by distortion can be expressed by certain latent characteristics. Combined with probabilistic latent semantic analysis, the latent characteristics can be discovered by applying a topic model over a visual word dictionary. Four distortion-affected features are extracted to form the visual words in the dictionary: (1) the block-based local histogram; (2) the block-based local mean value; (3) the mean value of contrast within a block; (4) the variance of contrast within a block. Based on the dictionary, the latent topics in the images can be discovered. The discrepancy between the frequency of the topics in an unfamiliar image and a large number of pristine images is applied to measure the image quality. Experimental results for four open databases show that the newly proposed method correlates well with human subjective judgments of diversely distorted images.

  10. A web-based screening tool for near-port air quality assessments

    PubMed Central

    Isakov, Vlad; Barzyk, Timothy M.; Smith, Elizabeth R.; Arunachalam, Saravanan; Naess, Brian; Venkatram, Akula

    2018-01-01

    The Community model for near-PORT applications (C-PORT) is a screening tool with an intended purpose of calculating differences in annual averaged concentration patterns and relative contributions of various source categories over the spatial domain within about 10 km of the port. C-PORT can inform decision-makers and concerned citizens about local air quality due to mobile source emissions related to commercial port activities. It allows users to visualize and evaluate different planning scenarios, helping them identify the best alternatives for making long-term decisions that protect community health and sustainability. The web-based, easy-to-use interface currently includes data from 21 seaports primarily in the Southeastern U.S., and has a map-based interface based on Google Maps. The tool was developed to visualize and assess changes in air quality due to changes in emissions and/or meteorology in order to analyze development scenarios, and is not intended to support or replace any regulatory models or programs. PMID:29681760

  11. Visual function and quality of life among visually impaired and cataract operated adults. The Pakistan National Blindness and Visual Impairment Survey.

    PubMed

    Taylor, Amy E; Shah, Shaheen P; Gilbert, Clare E; Jadoon, Mohammad Z; Bourne, Rupert R A; Dineen, Brendan; Johnson, Gordon J; Khan, Mohammad D

    2008-01-01

    To assess visual functioning and quality of life in a representative sample of normally sighted, visually impaired and cataract operated individuals aged >or= 30 years in Pakistan. As part of the Pakistan National Blindness and Visual Impairment Survey, visual functioning (VF) and quality of life (QOL) questionnaires were administered to participants with presenting visual acuity less than 6/60 in either eye, aphakes/pseudophakes and a phakic sample with normal acuity (>or= 6/12 both eyes). Of 16,507 adults included in the survey, 2329 questionnaires were administered. There were strong correlations between visual acuity and VF/QOL. Mean VF and median QOL scores in normally sighted phakic individuals were 81.1 and 88.9, respectively, but were only 34.8 and 64.9 in blind unoperated individuals. In the cataract operated population overall mean VF and median QOL scores were 49.3 and 75.0. Both VF and QOL scores were lower in operated individuals than unoperated individuals (p < 0.001). Among operated individuals, rural dwelling and illiteracy were associated with lower VF and QOL scores (p all < 0.02). Although in multivariable analysis bilateral pseudophakes had similar VF scores to bilateral aphakes they had significantly better QOL scores (p = 0.001). Cataract surgery in Pakistan has not led to VF and QOL scores equivalent to those in unoperated individuals with the same levels of visual acuity. The higher proportion of intraocular lens surgery in recent years is likely to improve QOL following cataract surgery. Further focus is needed on rural and illiterate populations, to ensure that they achieve comparable VF/QOL outcomes following surgery.

  12. Audio-visual presentation of information for informed consent for participation in clinical trials.

    PubMed

    Ryan, R E; Prictor, M J; McLaughlin, K J; Hill, S J

    2008-01-23

    Informed consent is a critical component of clinical research. Different methods of presenting information to potential participants of clinical trials may improve the informed consent process. Audio-visual interventions (presented for example on the Internet, DVD, or video cassette) are one such method. To assess the effects of providing audio-visual information alone, or in conjunction with standard forms of information provision, to potential clinical trial participants in the informed consent process, in terms of their satisfaction, understanding and recall of information about the study, level of anxiety and their decision whether or not to participate. We searched: the Cochrane Consumers and Communication Review Group Specialised Register (searched 20 June 2006); the Cochrane Central Register of Controlled Trials (CENTRAL), The Cochrane Library, issue 2, 2006; MEDLINE (Ovid) (1966 to June week 1 2006); EMBASE (Ovid) (1988 to 2006 week 24); and other databases. We also searched reference lists of included studies and relevant review articles, and contacted study authors and experts. There were no language restrictions. Randomised and quasi-randomised controlled trials comparing audio-visual information alone, or in conjunction with standard forms of information provision (such as written or oral information as usually employed in the particular service setting), with standard forms of information provision alone, in the informed consent process for clinical trials. Trials involved individuals or their guardians asked to participate in a real (not hypothetical) clinical study. Two authors independently assessed studies for inclusion and extracted data. Due to heterogeneity no meta-analysis was possible; we present the findings in a narrative review. We included 4 trials involving data from 511 people. Studies were set in the USA and Canada. Three were randomised controlled trials (RCTs) and the fourth a quasi-randomised trial. Their quality was mixed and results should be interpreted with caution. Considerable uncertainty remains about the effects of audio-visual interventions, compared with standard forms of information provision (such as written or oral information normally used in the particular setting), for use in the process of obtaining informed consent for clinical trials. Audio-visual interventions did not consistently increase participants' levels of knowledge/understanding (assessed in four studies), although one study showed better retention of knowledge amongst intervention recipients. An audio-visual intervention may transiently increase people's willingness to participate in trials (one study), but this was not sustained at two to four weeks post-intervention. Perceived worth of the trial did not appear to be influenced by an audio-visual intervention (one study), but another study suggested that the quality of information disclosed may be enhanced by an audio-visual intervention. Many relevant outcomes including harms were not measured. The heterogeneity in results may reflect the differences in intervention design, content and delivery, the populations studied and the diverse methods of outcome assessment in included studies. The value of audio-visual interventions for people considering participating in clinical trials remains unclear. Evidence is mixed as to whether audio-visual interventions enhance people's knowledge of the trial they are considering entering, and/or the health condition the trial is designed to address; one study showed improved retention of knowledge amongst intervention recipients. The intervention may also have small positive effects on the quality of information disclosed, and may increase willingness to participate in the short-term; however the evidence is weak. There were no data for several primary outcomes, including harms. In the absence of clear results, triallists should continue to explore innovative methods of providing information to potential trial participants. Further research should take the form of high-quality randomised controlled trials, with clear reporting of methods. Studies should conduct content assessment of audio-visual and other innovative interventions for people of differing levels of understanding and education; also for different age and cultural groups. Researchers should assess systematically the effects of different intervention components and delivery characteristics, and should involve consumers in intervention development. Studies should assess additional outcomes relevant to individuals' decisional capacity, using validated tools, including satisfaction; anxiety; and adherence to the subsequent trial protocol.

  13. A Locally Weighted Fixation Density-Based Metric for Assessing the Quality of Visual Saliency Predictions

    NASA Astrophysics Data System (ADS)

    Gide, Milind S.; Karam, Lina J.

    2016-08-01

    With the increased focus on visual attention (VA) in the last decade, a large number of computational visual saliency methods have been developed over the past few years. These models are traditionally evaluated by using performance evaluation metrics that quantify the match between predicted saliency and fixation data obtained from eye-tracking experiments on human observers. Though a considerable number of such metrics have been proposed in the literature, there are notable problems in them. In this work, we discuss shortcomings in existing metrics through illustrative examples and propose a new metric that uses local weights based on fixation density which overcomes these flaws. To compare the performance of our proposed metric at assessing the quality of saliency prediction with other existing metrics, we construct a ground-truth subjective database in which saliency maps obtained from 17 different VA models are evaluated by 16 human observers on a 5-point categorical scale in terms of their visual resemblance with corresponding ground-truth fixation density maps obtained from eye-tracking data. The metrics are evaluated by correlating metric scores with the human subjective ratings. The correlation results show that the proposed evaluation metric outperforms all other popular existing metrics. Additionally, the constructed database and corresponding subjective ratings provide an insight into which of the existing metrics and future metrics are better at estimating the quality of saliency prediction and can be used as a benchmark.

  14. Evaluation of differences in quality of experience features for test stimuli of good-only and bad-only overall audiovisual quality

    NASA Astrophysics Data System (ADS)

    Strohmeier, Dominik; Kunze, Kristina; Göbel, Klemens; Liebetrau, Judith

    2013-01-01

    Assessing audiovisual Quality of Experience (QoE) is a key element to ensure quality acceptance of today's multimedia products. The use of descriptive evaluation methods allows evaluating QoE preferences and the underlying QoE features jointly. From our previous evaluations on QoE for mobile 3D video we found that mainly one dimension, video quality, dominates the descriptive models. Large variations of the visual video quality in the tests may be the reason for these findings. A new study was conducted to investigate whether test sets of low QoE are described differently than those of high audiovisual QoE. Reanalysis of previous data sets seems to confirm this hypothesis. Our new study consists of a pre-test and a main test, using the Descriptive Sorted Napping method. Data sets of good-only and bad-only video quality were evaluated separately. The results show that the perception of bad QoE is mainly determined one-dimensionally by visual artifacts, whereas the perception of good quality shows multiple dimensions. Here, mainly semantic-related features of the content and affective descriptors are used by the naïve test participants. The results show that, with increasing QoE of audiovisual systems, content semantics and users' a_ective involvement will become important for assessing QoE differences.

  15. Alaska national hydrography dataset positional accuracy assessment study

    USGS Publications Warehouse

    Arundel, Samantha; Yamamoto, Kristina H.; Constance, Eric; Mantey, Kim; Vinyard-Houx, Jeremy

    2013-01-01

    Initial visual assessments Wide range in the quality of fit between features in NHD and these new image sources. No statistical analysis has been performed to actually quantify accuracy Determining absolute accuracy is cost prohibitive (must collect independent, well defined test points) Quantitative analysis of relative positional error is feasible.

  16. The effect of step stool use and provider height on CPR quality during pediatric cardiac arrest: A simulation-based multicentre study.

    PubMed

    Cheng, Adam; Lin, Yiqun; Nadkarni, Vinay; Wan, Brandi; Duff, Jonathan; Brown, Linda; Bhanji, Farhan; Kessler, David; Tofil, Nancy; Hecker, Kent; Hunt, Elizabeth A

    2018-01-01

    We aimed to explore whether a) step stool use is associated with improved cardiopulmonary resuscitation (CPR) quality; b) provider adjusted height is associated with improved CPR quality; and if associations exist, c) determine whether just-in-time (JIT) CPR training and/or CPR visual feedback attenuates the effect of height and/or step stool use on CPR quality. We analysed data from a trial of simulated cardiac arrests with three study arms: No intervention; CPR visual feedback; and JIT CPR training. Step stool use was voluntary. We explored the association between 1) step stool use and CPR quality, and 2) provider adjusted height and CPR quality. Adjusted height was defined as provider height + 23 cm (if step stool was used). Below-average height participants were ≤ gender-specific average height; the remainder were above average height. We assessed for interaction between study arm and both adjusted height and step stool use. One hundred twenty-four subjects participated; 1,230 30-second epochs of CPR were analysed. Step stool use was associated with improved compression depth in below-average (female, p=0.007; male, p<0.001) and above-average (female, p=0.001; male, p<0.001) height providers. There is an association between adjusted height and compression depth (p<0.001). Visual feedback attenuated the effect of height (p=0.025) on compression depth; JIT training did not (p=0.918). Visual feedback and JIT training attenuated the effect of step stool use (p<0.001) on compression depth. Step stool use is associated with improved compression depth regardless of height. Increased provider height is associated with improved compression depth, with visual feedback attenuating the effects of height and step stool use.

  17. Testing the Visual Soil Assessment tool on Estonian farm fields

    NASA Astrophysics Data System (ADS)

    Reintam, Endla; Are, Mihkel; Selge, Are

    2017-04-01

    Soil quality estimation plays important role in decision making on farm as well on policy level. Sustaining the production ability and good health of the soil the chemical, physical and biological indicators should be taken into account. The system to use soil chemical parameters is usually quite well established in most European counties, including Estonia. However, measuring soil physical properties, such bulk density, porosity, penetration resistance, structural stability ect is time consuming, needs special tools and is highly weather dependent. In that reason these parameters are excluded from controllable quality parameters in policy in Estonia. Within the project "Interactive Soil Quality Assessment in Europe and China for Agricultural Productivity and Environmental Resilience" (iSQAPER) the visual soil assessment (VSA) tool was developed for easy detection of soil quality as well the different soil friendly agricultural management practices (AMP) were detected. The aim of current study was to test the VSA tool on Estonian farm fields under different management practices and compare the results with laboratory measurements. The main focus was set on soil physical parameters. Next to the VSA, the undisturbed soil samples were collected from the depth of 5-10 cm and 25-30 cm. The study revealed that results of a visually assessed soil physical parameters, such a soil structure, soil structural stability, soil porosity, presence of tillage pan, were confirmed by laboratory measurements in most cases. Soil water stable structure measurement on field (on 1 cm2 net in one 1 l box with 4-6 cm air dry clods for 5-10 min) underestimated very well structured soil on grassland and overestimated the structure aggregates stability of compacted soil. The slightly better soil quality was detected under no-tillage compared to ploughed soils. However, the ploughed soil got higher quality points compared with minimum tillage. The slurry application (organic manuring) had controversial impact - it increased the number of earthworms but decreased soil structural stability. Even the manuring with slurry increases organic matter amount in the soil, the compaction due to the use of heavy machinery during the application, especially on wet soil, reduces the positive effect of slurry.

  18. Methodology for cork plank characterization (Quercus suber L.) by near-infrared spectroscopy and image analysis

    NASA Astrophysics Data System (ADS)

    Prades, Cristina; García-Olmo, Juan; Romero-Prieto, Tomás; García de Ceca, José L.; López-Luque, Rafael

    2010-06-01

    The procedures used today to characterize cork plank for the manufacture of cork bottle stoppers continue to be based on a traditional, manual method that is highly subjective. Furthermore, there is no specific legislation regarding cork classification. The objective of this viability study is to assess the potential of near-infrared spectroscopy (NIRS) technology for characterizing cork plank according to the following variables: aspect or visual quality, porosity, moisture and geographical origin. In order to calculate the porosity coefficient, an image analysis program was specifically developed in Visual Basic language for a desktop scanner. A set comprising 170 samples from two geographical areas of Andalusia (Spain) was classified into eight quality classes by visual inspection. Spectra were obtained in the transverse and tangential sections of the cork planks using an NIRSystems 6500 SY II reflectance spectrophotometer. The quantitative calibrations showed cross-validation coefficients of determination of 0.47 for visual quality, 0.69 for porosity and 0.66 for moisture. The results obtained using NIRS technology are promising considering the heterogeneity and variability of a natural product such as cork in spite of the fact that the standard error of cross validation (SECV) in the quantitative analysis is greater than the standard error of laboratory (SEL) for the three variables. The qualitative analysis regarding geographical origin achieved very satisfactory results. Applying these methods in industry will permit quality control procedures to be automated, as well as establishing correlations between the different classification systems currently used in the sector. These methods can be implemented in the cork chain of custody certification and will also provide a certainly more objective tool for assessing the economic value of the product.

  19. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    PubMed

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting.

  20. An evaluation of the use of oral contrast media in abdominopelvic CT.

    PubMed

    Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis

    2014-11-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.

  1. ShortRead: a bioconductor package for input, quality assessment and exploration of high-throughput sequence data

    PubMed Central

    Morgan, Martin; Anders, Simon; Lawrence, Michael; Aboyoun, Patrick; Pagès, Hervé; Gentleman, Robert

    2009-01-01

    Summary: ShortRead is a package for input, quality assessment, manipulation and output of high-throughput sequencing data. ShortRead is provided in the R and Bioconductor environments, allowing ready access to additional facilities for advanced statistical analysis, data transformation, visualization and integration with diverse genomic resources. Availability and Implementation: This package is implemented in R and available at the Bioconductor web site; the package contains a ‘vignette’ outlining typical work flows. Contact: mtmorgan@fhcrc.org PMID:19654119

  2. Big data and visual analytics in anaesthesia and health care.

    PubMed

    Simpao, A F; Ahumada, L M; Rehman, M A

    2015-09-01

    Advances in computer technology, patient monitoring systems, and electronic health record systems have enabled rapid accumulation of patient data in electronic form (i.e. big data). Organizations such as the Anesthesia Quality Institute and Multicenter Perioperative Outcomes Group have spearheaded large-scale efforts to collect anaesthesia big data for outcomes research and quality improvement. Analytics--the systematic use of data combined with quantitative and qualitative analysis to make decisions--can be applied to big data for quality and performance improvements, such as predictive risk assessment, clinical decision support, and resource management. Visual analytics is the science of analytical reasoning facilitated by interactive visual interfaces, and it can facilitate performance of cognitive activities involving big data. Ongoing integration of big data and analytics within anaesthesia and health care will increase demand for anaesthesia professionals who are well versed in both the medical and the information sciences. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Potential future impacts on visual air quality for Class I areas

    Treesearch

    Gurule Nochumson; Mona J. Wecksung

    1979-01-01

    Visual air quality is most sensitive to degradation by air pollution in areas with good visibility. The protection of visual air quality in mandatory Class I Federal areas has been declared a national goal by Congress. Impacts on visual air quality are calculated for 154 Class I areas where visual air quality is considered an important value. These impacts are...

  4. A Method to Quantify Visual Information Processing in Children Using Eye Tracking

    PubMed Central

    Kooiker, Marlou J.G.; Pel, Johan J.M.; van der Steen-Kant, Sanny P.; van der Steen, Johannes

    2016-01-01

    Visual problems that occur early in life can have major impact on a child's development. Without verbal communication and only based on observational methods, it is difficult to make a quantitative assessment of a child's visual problems. This limits accurate diagnostics in children under the age of 4 years and in children with intellectual disabilities. Here we describe a quantitative method that overcomes these problems. The method uses a remote eye tracker and a four choice preferential looking paradigm to measure eye movement responses to different visual stimuli. The child sits without head support in front of a monitor with integrated infrared cameras. In one of four monitor quadrants a visual stimulus is presented. Each stimulus has a specific visual modality with respect to the background, e.g., form, motion, contrast or color. From the reflexive eye movement responses to these specific visual modalities, output parameters such as reaction times, fixation accuracy and fixation duration are calculated to quantify a child's viewing behavior. With this approach, the quality of visual information processing can be assessed without the use of communication. By comparing results with reference values obtained in typically developing children from 0-12 years, the method provides a characterization of visual information processing in visually impaired children. The quantitative information provided by this method can be advantageous for the field of clinical visual assessment and rehabilitation in multiple ways. The parameter values provide a good basis to: (i) characterize early visual capacities and consequently to enable early interventions; (ii) compare risk groups and follow visual development over time; and (iii), construct an individual visual profile for each child. PMID:27500922

  5. A Method to Quantify Visual Information Processing in Children Using Eye Tracking.

    PubMed

    Kooiker, Marlou J G; Pel, Johan J M; van der Steen-Kant, Sanny P; van der Steen, Johannes

    2016-07-09

    Visual problems that occur early in life can have major impact on a child's development. Without verbal communication and only based on observational methods, it is difficult to make a quantitative assessment of a child's visual problems. This limits accurate diagnostics in children under the age of 4 years and in children with intellectual disabilities. Here we describe a quantitative method that overcomes these problems. The method uses a remote eye tracker and a four choice preferential looking paradigm to measure eye movement responses to different visual stimuli. The child sits without head support in front of a monitor with integrated infrared cameras. In one of four monitor quadrants a visual stimulus is presented. Each stimulus has a specific visual modality with respect to the background, e.g., form, motion, contrast or color. From the reflexive eye movement responses to these specific visual modalities, output parameters such as reaction times, fixation accuracy and fixation duration are calculated to quantify a child's viewing behavior. With this approach, the quality of visual information processing can be assessed without the use of communication. By comparing results with reference values obtained in typically developing children from 0-12 years, the method provides a characterization of visual information processing in visually impaired children. The quantitative information provided by this method can be advantageous for the field of clinical visual assessment and rehabilitation in multiple ways. The parameter values provide a good basis to: (i) characterize early visual capacities and consequently to enable early interventions; (ii) compare risk groups and follow visual development over time; and (iii), construct an individual visual profile for each child.

  6. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    PubMed

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p < 0.05). Only the utility scores measured with RS were significantly correlated with the composite OSDI score, "environmental trigger" and "eye discomfort" section scores (p < 0.05). RS is more sensitive than TTO and SG for the evaluation of altered quality of life due to dry eye symptoms.

  7. Visually Impaired Drivers Who Use Bioptic Telescopes: Self-Assessed Driving Skills and Agreement With On-Road Driving Evaluation

    PubMed Central

    Owsley, Cynthia; McGwin, Gerald; Elgin, Jennifer; Wood, Joanne M.

    2014-01-01

    Purpose. To compare self-assessed driving habits and skills of licensed drivers with central visual loss who use bioptic telescopes to those of age-matched normally sighted drivers, and to examine the association between bioptic drivers' impressions of the quality of their driving and ratings by a “backseat” evaluator. Methods. Participants were licensed bioptic drivers (n = 23) and age-matched normally sighted drivers (n = 23). A questionnaire was administered addressing driving difficulty, space, quality, exposure, and, for bioptic drivers, whether the telescope was helpful in on-road situations. Visual acuity and contrast sensitivity were assessed. Information on ocular diagnosis, telescope characteristics, and bioptic driving experience was collected from the medical record or in interview. On-road driving performance in regular traffic conditions was rated independently by two evaluators. Results. Like normally sighted drivers, bioptic drivers reported no or little difficulty in many driving situations (e.g., left turns, rush hour), but reported more difficulty under poor visibility conditions and in unfamiliar areas (P < 0.05). Driving exposure was reduced in bioptic drivers (driving 250 miles per week on average vs. 410 miles per week for normally sighted drivers, P = 0.02), but driving space was similar to that of normally sighted drivers (P = 0.29). All but one bioptic driver used the telescope in at least one driving task, and 56% used the telescope in three or more tasks. Bioptic drivers' judgments about the quality of their driving were very similar to backseat evaluators' ratings. Conclusions. Bioptic drivers show insight into the overall quality of their driving and areas in which they experience driving difficulty. They report using the bioptic telescope while driving, contrary to previous claims that it is primarily used to pass the vision screening test at licensure. PMID:24370830

  8. Visually impaired drivers who use bioptic telescopes: self-assessed driving skills and agreement with on-road driving evaluation.

    PubMed

    Owsley, Cynthia; McGwin, Gerald; Elgin, Jennifer; Wood, Joanne M

    2014-01-15

    To compare self-assessed driving habits and skills of licensed drivers with central visual loss who use bioptic telescopes to those of age-matched normally sighted drivers, and to examine the association between bioptic drivers' impressions of the quality of their driving and ratings by a "backseat" evaluator. Participants were licensed bioptic drivers (n = 23) and age-matched normally sighted drivers (n = 23). A questionnaire was administered addressing driving difficulty, space, quality, exposure, and, for bioptic drivers, whether the telescope was helpful in on-road situations. Visual acuity and contrast sensitivity were assessed. Information on ocular diagnosis, telescope characteristics, and bioptic driving experience was collected from the medical record or in interview. On-road driving performance in regular traffic conditions was rated independently by two evaluators. Like normally sighted drivers, bioptic drivers reported no or little difficulty in many driving situations (e.g., left turns, rush hour), but reported more difficulty under poor visibility conditions and in unfamiliar areas (P < 0.05). Driving exposure was reduced in bioptic drivers (driving 250 miles per week on average vs. 410 miles per week for normally sighted drivers, P = 0.02), but driving space was similar to that of normally sighted drivers (P = 0.29). All but one bioptic driver used the telescope in at least one driving task, and 56% used the telescope in three or more tasks. Bioptic drivers' judgments about the quality of their driving were very similar to backseat evaluators' ratings. Bioptic drivers show insight into the overall quality of their driving and areas in which they experience driving difficulty. They report using the bioptic telescope while driving, contrary to previous claims that it is primarily used to pass the vision screening test at licensure.

  9. Reliability of a computer-based system for measuring visual performance skills.

    PubMed

    Erickson, Graham B; Citek, Karl; Cove, Michelle; Wilczek, Jennifer; Linster, Carolyn; Bjarnason, Brendon; Langemo, Nathan

    2011-09-01

    Athletes have demonstrated better visual abilities than nonathletes. A vision assessment for an athlete should include methods to evaluate the quality of visual performance skills in the most appropriate, accurate, and repeatable manner. This study determines the reliability of the visual performance measures assessed with a computer-based system, known as the Nike Sensory Station. One hundred twenty-five subjects (56 men, 69 women), age 18 to 30, completed Phase I of the study. Subjects attended 2 sessions, separated by at least 1 week, in which identical protocols were followed. Subjects completed the following assessments: Visual Clarity, Contrast Sensitivity, Depth Perception, Near-Far Quickness, Target Capture, Perception Span, Eye-Hand Coordination, Go/No Go, and Reaction Time. An additional 36 subjects (20 men, 16 women), age 22 to 35, completed Phase II of the study involving modifications to the equipment, instructions, and protocols from Phase I. Results show no significant change in performance over time on assessments of Visual Clarity, Contrast Sensitivity, Depth Perception, Target Capture, Perception Span, and Reaction Time. Performance did improve over time for Near-Far Quickness, Eye-Hand Coordination, and Go/No Go. The results of this study show that many of the Nike Sensory Station assessments show repeatability and no learning effect over time. The measures that did improve across sessions show an expected learning effect caused by the motor response characteristics being measured. Copyright © 2011 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  10. A survey of educational uses of molecular visualization freeware.

    PubMed

    Craig, Paul A; Michel, Lea Vacca; Bateman, Robert C

    2013-01-01

    As biochemists, one of our most captivating teaching tools is the use of molecular visualization. It is a compelling medium that can be used to communicate structural information much more effectively with interactive animations than with static figures. We have conducted a survey to begin a systematic evaluation of the current classroom usage of molecular visualization. Participants (n = 116) were asked to complete 11 multiple choice and 3 open ended questions. To provide more depth to these results, interviews were conducted with 12 of the participants. Many common themes arose in the survey and the interviews: a shared passion for the use of molecular visualization in teaching, broad diversity in software preference, the lack of uniform standards for assessment, a desire for more quality resources, and the challenge of enabling students to incorporate visualization in their learning. The majority of respondents had used molecular visualization for more than 5 years and mentioned 32 different visualization tools used, with Jmol and PyMOL clearly standing out as the most frequently used programs at the present time. The most common uses of molecular visualization in teaching were lecture and lab illustrations, followed by exam questions, in-class or in-laboratory exercises, and student projects, which frequently included presentations. While a minority of instructors used a grading rubric/scoring matrix for assessment of student learning with molecular visualization, many expressed a desire for common use assessment tools. Copyright © 2013 International Union of Biochemistry and Molecular Biology, Inc.

  11. Assessing Student Scientific Expression Using Media: The Media-Enhanced Science Presentation Rubric (MESPR)

    ERIC Educational Resources Information Center

    Mott, Michael S.; Chessin, Debby A.; Sumrall, William J.; Rutherford, Angela S.; Moore, Virginia J.

    2011-01-01

    The current study evaluated an assessment designed to dually promote student understanding of the experimental method and student ability to include digital and visual qualities in their presentations of scientific experiment results. The rubric, the Media-Enhanced Science Presentation Rubric (MESPR) focuses teacher-student dialogue along the…

  12. Developing and evaluating a target-background similarity metric for camouflage detection.

    PubMed

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Liu, Bor-Shong

    2014-01-01

    Measurement of camouflage performance is of fundamental importance for military stealth applications. The goal of camouflage assessment algorithms is to automatically assess the effect of camouflage in agreement with human detection responses. In a previous study, we found that the Universal Image Quality Index (UIQI) correlated well with the psychophysical measures, and it could be a potentially camouflage assessment tool. In this study, we want to quantify the camouflage similarity index and psychophysical results. We compare several image quality indexes for computational evaluation of camouflage effectiveness, and present the results of an extensive human visual experiment conducted to evaluate the performance of several camouflage assessment algorithms and analyze the strengths and weaknesses of these algorithms. The experimental data demonstrates the effectiveness of the approach, and the correlation coefficient result of the UIQI was higher than those of other methods. This approach was highly correlated with the human target-searching results. It also showed that this method is an objective and effective camouflage performance evaluation method because it considers the human visual system and image structure, which makes it consistent with the subjective evaluation results.

  13. The impact of glaucoma on quality of life in Ethiopia: a case-control study.

    PubMed

    Ayele, Fisseha A; Zeraye, Banchamelak; Assefa, Yared; Legesse, Kbrom; Azale, Telake; Burton, Matthew J

    2017-12-13

    Glaucoma is a chronic disease characterized by irreversible optic nerve damage and visual field loss that leads to visual impairment and blindness; ultimately limiting personal independence and compromising overall quality of life of affected individuals. There is paucity of information on how glaucoma affects the quality of life of patients in low and middle-income countries where resources for both diagnosis and treatment of such conditions are limited. In this study we investigate the impact of glaucoma on quality of life in Ethiopian patients. The quality of life of 307 glaucoma patients and 76 normal controls that were frequency matched to the age and sex profiles of the cases was assessed using Amharic version of Glaucoma Quality of Life -15 questionnaire. Linear regression models and the t-test were employed to compare significant differences in GQL-15 scores and to generate mean and mean differences between cases and controls respectively. The mean GQL-15 score in the glaucoma cases was substantially higher (indicating poorer quality of life) than the controls [cases 46.3 (95% CI, 28.8-63.8) and controls 18.6 (95% CI, 15.2-22.0), p < 0.0001]. Cases with normal visual acuity and mild glaucoma had significantly higher scores than the controls. Poorer quality of life was associated with age ≥ 71 years old 51.1 (95%CI, 26.2-75.9), rural residence 55.7 (95%CI, 49.9-61.5), monthly income of <400 Birr (53.1; 95%CI, 50.5-55.6), diagnosis time 1-5 years (49.6; 95%CI, 41.2-57.9), severe visual impairment (70.5; 95%CI, 58.1-82.8), and advanced glaucoma (50.9; 95%CI, 43.6-58.3). These glaucoma patients, including those with normal visual acuity and early disease, had poorer quality of life compared to normal controls. Older age, rural residence, low income and more advanced disease were significantly associated with poorer quality of life. There is a need to increase awareness of the impact of glaucoma among clinicians, patients and their families, for a better understanding of the impact this disease has on a person's life.

  14. [Studying of life's quality changes among children of the first three year of life with visual analyzer's congenital pathology as instrument of their social adaptation's formation in the future became a research objective].

    PubMed

    Medvedovska, Nataliia V; Bukhanovska, Tetiana M; Shevchyk, Anatolii A

    The study of the composite qualities of life is an important component of the quality of provided medical aid. The way of our investigation that was chosen by us, the quality of life of the children of first years of life with the congenital pathology of vision arises the significant problem of assessment of its changes, because children of these ages can't take part in an interview and we adapted the standard questionnaire "Children Visual Function Questionnaire" (CVFQ) with its help the components of quality of the children of first years of life assess their parents. Studying of life's quality changes among children of the first three year of life with visual analyzer's congenital pathology as instrument of their social adaptation's formation in the future became a research objective. Out-patient and polyclinic units of Kyiv's healthcare institutions in which the medical care is provided to children of the first three years of life, particularly with congenital ophthalmic pathology (3 institutions) were scientific base of a research. We have been used the adapted version of the standardized questionnaire of Children's Visual Function Questionnaire (CVFQ) Felius et al were primary material. (2004) - 498 questionnaires, from them 398 of the main group and 100 of control. The purpose of a research required using the complex of research methods, a basis for which is a system approach, namely: medico-statistical and sociological (the respondents were informed about the purpose and research problems and timely gave the oral voluntary agreement in anonymous poll before the filling of questionnaires) methods. The results of a research has established that parents of children from control group have estimated the general condition of children's vision totally in 89,75 ± 1,33 points vs 60,25 ± 1,96 points according to a total score of children's parents from the main group (the difference was 32,87%, at р<0,001). In general, the total number of points was 64,89 ± 1,01 vs 84,67 ± 0,92, with a difference in 23,4% (р<0,001) in the main group, according to life's quality total score of early years children's parents. Our research proves existence of children's life quality changes at the presence of visual violations among them that substantiates expediency of strengthening of early identification and treatment measures of visual function's violations at children, within the approved medico-technological documents. Interaction in form of cooperation between the family doctor and children's ophthalmologist within the competences on maintaining children with visual analyzer's violation of functions from the first days of life, allows to perform effective long observation of a family, preventing development of medico-social disadaptation both the child, and a family in which it appeared. Research results of life's quality components changes are informative for a future social functioning of the child, his family, the parent's attitude to a child's disease and it's treatments, and performance of disease's treatment.

  15. Reading performance with low-vision aids and vision-related quality of life after macular translocation surgery in patients with age-related macular degeneration.

    PubMed

    Nguyen, Nhung X; Besch, Dorothea; Bartz-Schmidt, Karl; Gelisken, Faik; Trauzettel-Klosinski, Susanne

    2007-12-01

    The aim of the present study was to evaluate the power of magnification required, reading performance with low-vision aids and vision-related quality of life with reference to reading ability and ability to carry out day-to-day activities in patients after macular translocation. This study included 15 patients who had undergone macular translocation with 360-degree peripheral retinectomy. The mean length of follow-up was 19.2 +/- 10.8 months (median 11 months). At the final examination, the impact of visual impairment on reading ability and quality of life was assessed according to a modified 9-item questionnaire in conjunction with a comprehensive clinical examination, which included assessment of best corrected visual acuity (BCVA), the magnification power required for reading, use of low-vision aids and reading speed. Patients rated the extent to which low vision restricted their ability to read and participate in other activities that affect quality of life. Responses were scored on a scale of 1.0 (optimum self-evaluation) to 5.0 (very poor). In the operated eye, overall mean postoperative BCVA (distance) was not significantly better than mean preoperative BCVA (0.11 +/- 0.06 and 0.15 +/- 0.08, respectively; p = 0.53). However, 53% of patients reported a subjective increase in visual function after treatment. At the final visit, the mean magnification required was x 7.7 +/- 6.7. A total of 60% of patients needed optical magnifiers for reading and in 40% of patients closed-circuit TV systems were necessary. All patients were able to read newspaper print using adapted low-vision aids at a mean reading speed of 71 +/- 40 words per minute. Mean self-reported scores were 3.2 +/- 1.1 for reading, 2.5 +/- 0.7 for day-to-day activities and 2.7 +/- 3.0 for outdoor walking and using steps or stairs. Patients' levels of dependency were significantly correlated with scores for reading (p = 0.01), day-to-day activities (p < 0.001) and outdoor walking and using steps (p = 0.001). The evaluation of self-reported visual function and vision-related quality of life in patients after macular translocation is necessary to obtain detailed information on treatment effects. Our results indicated improvement in patients' subjective evaluations of visual function, without significant improvement in visual acuity. The postoperative clinical benefits of treatment coincide with subjective benefits in terms of reading ability, quality of life and patient satisfaction. Our study confirms the importance and efficiency of visual rehabilitation with aids for low vision after surgery.

  16. Systematic Assessment of the Hemolysis Index: Pros and Cons.

    PubMed

    Lippi, Giuseppe

    2015-01-01

    Preanalytical quality is as important as the analytical and postanalytical quality in laboratory diagnostics. After decades of visual inspection to establish whether or not a diagnostic sample may be suitable for testing, automated assessment of hemolysis index (HI) has now become available in a large number of laboratory analyzers. Although most national and international guidelines support systematic assessment of sample quality via HI, there is widespread perception that this indication has not been thoughtfully acknowledged. Potential explanations include concern of increased specimen rejection rate, poor harmonization of analytical techniques, lack of standardized units of measure, differences in instrument-specific cutoff, negative impact on throughput, organization and laboratory economics, and lack of a reliable quality control system. Many of these concerns have been addressed. Evidence now supports automated HI in improving quality and patient safety. These will be discussed. © 2015 Elsevier Inc. All rights reserved.

  17. The Recovery of Optical Quality after Laser Vision Correction

    PubMed Central

    Jung, Hyeong-Gi

    2013-01-01

    Purpose To evaluate the optical quality after laser in situ keratomileusis (LASIK) or serial photorefractive keratectomy (PRK) using a double-pass system and to follow the recovery of optical quality after laser vision correction. Methods This study measured the visual acuity, manifest refraction and optical quality before and one day, one week, one month, and three months after laser vision correction. Optical quality parameters including the modulation transfer function, Strehl ratio and intraocular scattering were evaluated with a double-pass system. Results This study included 51 eyes that underwent LASIK and 57 that underwent PRK. The optical quality three months post-surgery did not differ significantly between these laser vision correction techniques. Furthermore, the preoperative and postoperative optical quality did not differ significantly in either group. Optical quality recovered within one week after LASIK but took between one and three months to recover after PRK. The optical quality of patients in the PRK group seemed to recover slightly more slowly than their uncorrected distance visual acuity. Conclusions Optical quality recovers to the preoperative level after laser vision correction, so laser vision correction is efficacious for correcting myopia. The double-pass system is a useful tool for clinical assessment of optical quality. PMID:23908570

  18. Hemispheric differences in visual search of simple line arrays.

    PubMed

    Polich, J; DeFrancesco, D P; Garon, J F; Cohen, W

    1990-01-01

    The effects of perceptual organization on hemispheric visual-information processing were assessed with stimulus arrays composed of short lines arranged in columns. A visual-search task was employed in which subjects judged whether all the lines were vertical (same) or whether a single horizontal line was present (different). Stimulus-display organization was manipulated in two experiments by variation of line density, linear organization, and array size. In general, left-visual-field/right-hemisphere presentations demonstrated more rapid and accurate responses when the display was perceived as a whole. Right-visual-field/left-hemisphere superiorities were observed when the display organization coerced assessment of individual array elements because the physical qualities of the stimulus did not effect a gestalt whole. Response times increased somewhat with increases in array size, although these effects interacted with other stimulus variables. Error rates tended to follow the reaction-time patterns. The results suggest that laterality differences in visual search are governed by stimulus properties which contribute to, or inhibit, the perception of a display as a gestalt. The implications of these findings for theoretical interpretations of hemispheric specialization are discussed.

  19. Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate at 3 Tesla: Comparison With Standard Echo-Planar Imaging Technique for Image Quality and Tumor Assessment.

    PubMed

    Tamada, Tsutomu; Ream, Justin M; Doshi, Ankur M; Taneja, Samir S; Rosenkrantz, Andrew B

    The purpose of this study was to compare image quality and tumor assessment at prostate magnetic resonance imaging (MRI) between reduced field-of-view diffusion-weighted imaging (rFOV-DWI) and standard DWI (st-DWI). A total of 49 patients undergoing prostate MRI and MRI/ultrasound fusion-targeted biopsy were included. Examinations included st-DWI (field of view [FOV], 200 × 200 mm) and rFOV-DWI (FOV, 140 × 64 mm) using a 2-dimensional (2D) spatially-selective radiofrequency pulse and parallel transmission. Two readers performed qualitative assessments; a third reader performed quantitative evaluation. Overall image quality, anatomic distortion, visualization of capsule, and visualization of peripheral/transition zone edge were better for rFOV-DWI for reader 1 (P ≤ 0.002), although not for reader 2 (P ≥ 0.567). For both readers, sensitivity, specificity, and accuracy for tumor with a Gleason Score (GS) of 3 + 4 or higher were not different (P ≥ 0.289). Lesion clarity was higher for st-DWI for reader 2 (P = 0.008), although similar for reader 1 (P = 0.409). Diagnostic confidence was not different for either reader (P ≥ 0.052). Tumor-to-benign apparent diffusion coefficient ratio was not different (P = 0.675). Potentially improved image quality of rFOV-DWI did not yield improved tumor assessment. Continued optimization is warranted.

  20. Contrast-enhanced ultrasonography vs B-mode ultrasound for visualization of intima-media thickness and detection of plaques in human carotid arteries.

    PubMed

    Shah, Benoy N; Chahal, Navtej S; Kooner, Jaspal S; Senior, Roxy

    2017-05-01

    Carotid intima-media thickness (IMT) and plaque are recognized markers of increased risk for cerebrovascular events. Accurate visualization of the IMT and plaques is dependent upon image quality. Ultrasound contrast agents improve image quality during echocardiography-this study assessed whether contrast-enhanced ultrasound (CEUS) improves carotid IMT visualization and plaque detection in an asymptomatic population. Individuals free from known cardiovascular disease, enrolled in a community study, underwent B-mode and CEUS carotid imaging. Each carotid artery was divided into 10 segments (far and near walls of the proximal, mid and distal segments of the common carotid artery, the carotid bulb, and internal carotid artery). Visualization of the IMT complex and plaque assessments was made during both B-mode and CEUS imaging for all enrolled subjects, a total of 175 individuals (mean age 65±9 years). Visualization of the IMT was significantly improved during CEUS compared with B-mode imaging, in both near and far walls of the carotid arteries (% IMT visualization during B-mode vs CEUS imaging: 61% vs 94% and 66% vs 95% for right and left carotid arteries, respectively, P<.001 for both). Additionally, a greater number of plaques were detected during CEUS imaging compared with B-mode imaging (367 plaques vs 350 plaques, P=.02). Contrast-enhanced ultrasound improves visualization of the intima-media complex, in both near and far walls, of the common and internal carotid arteries and permits greater detection of carotid plaques. Further studies are required to determine whether there is incremental clinical and prognostic benefit related to superior plaque detection by CEUS. © 2017, Wiley Periodicals, Inc.

  1. Hygiene on maternity units: lessons from a needs assessment in Bangladesh and India

    PubMed Central

    Cross, Suzanne; Afsana, Kaosar; Banu, Morsheda; Mavalankar, Dileep; Morrison, Emma; Rahman, Atiya; Roy, Tapash; Saxena, Deepak; Vora, Kranti; Graham, Wendy J

    2016-01-01

    Background As the proportion of deliveries in health institutions increases in low- and middle-income countries, so do the challenges of maintaining standards of hygiene and preventing healthcare-associated infections (HCAIs) in mothers and babies. Adequate water, sanitation, and hygiene (WASH) and infection prevention and control (IPC) in these settings should be seen as integral parts of the broader domain of quality care. Assessment approaches are needed which capture standards for both WASH and IPC, and so inform quality improvement processes. Design A needs assessment was conducted in seven maternity units in Gujarat, India, and eight in Dhaka Division, Bangladesh in 2014. The WASH & CLEAN study developed and applied a suite of tools – a ‘walkthrough checklist’ which included the collection of swab samples, a facility needs assessment tool and document review, and qualitative interviews with staff and recently delivered women – to establish the state of hygiene as measured by visual cleanliness and the presence of potential pathogens, and individual and contextual determinants or drivers. Results No clear relationship was found between visually assessed cleanliness and the presence of pathogens; findings from qualitative interviews and the facility questionnaire found inadequacies in IPC training for healthcare providers and no formal training at all for ward cleaners. Lack of written policies and protocols, and poor monitoring and supervision also contributed to suboptimal IPC standards. Conclusions Visual assessment of cleanliness and hygiene is an inadequate marker for ‘safety’ in terms of the presence of potential pathogens and associated risk of infection. Routine environmental screening of high-risk touch sites using simple microbiology could improve detection and control of pathogens. IPC training for both healthcare providers and ward cleaners represents an important opportunity for quality improvement. This should occur in conjunction with broader systems changes, including the establishment of functioning IPC committees, implementing standard policies and protocols, and improving health management information systems to capture information on maternal and newborn HCAIs. PMID:27964775

  2. Using Self-Determination of Senior College Students with Disabilities to Predict Their Quality of Life One Year after Graduation

    ERIC Educational Resources Information Center

    Chao, Pen-Chiang

    2018-01-01

    The purpose of this study was to assess the correlation and predictive relationship between self-determination and quality of life of college students with disabilities. Subjects were 145 senior college students recruited from northern Taiwan. Subjects' age ranged from 22 to 25 years and their disabilities varied, including visual impairments (n =…

  3. Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision.

    PubMed

    Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio

    2017-06-01

    To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Vision-related Quality of Life in Korean Glaucoma Patients.

    PubMed

    Sung, Kyung Rim; Chun, Yeoun Sook; Park, Chan Kee; Kim, Hwang Ki; Yoo, Chungkwon; Kim, Yong Yeon; Park, Ki Ho; Kim, Chan Yun; Choi, Kyu-Ryong; Lee, Kyoo Won; Han, Seungbong; Kim, Chang-Sik

    2017-02-01

    The purpose of the study was to evaluate vision-related quality of life in Korean glaucoma patients and to explore the associated factors. A total of 907 glaucoma patients were recruited from the prospectively designed LIGHT (Life quality of the glaucoma patient who underwent treatment) study organized by the Korean Glaucoma Society. Basic questionnaire that included items related to socioeconomic status, comorbidity, and lifestyle, and the validated Korean version of the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) were collected. The Rasch score, a logit-based interval scale estimate to summarizing the NEI VFQ-25 responses, was calculated. The univariate and multivariable regression models were used to evaluate associations between the Rasch score and variables. The mean patient age was 58.1±14.1 years, visual field mean deviation (VF MD) of the better and worse eyes was -4.92±6.14 and -9.77±8.31 dB, binocular-integrated VF (IVF) MD was -3.55±5.31 dB, respectively. The lower NEI VFQ-25 Rasch score showed a significant association with the presence of other ocular diseases (P=0.020), a high school level of education or less [vs. university (P=0.006), vs. graduate school or higher (P=0.019)], an anxious personality [vs. a moderate personality (P<0.001), vs. a relaxed personality (P<0.001)], the number of glaucoma medications in use (P=0.049), worse eye visual acuity (P<0.001), and IVF MD (P<0.001). Visual function parameters are important for the vision-related quality of life of Korean glaucoma patients, notably for worse eye visual acuity and IVF MD. However, social factors, self-assessed personality, and treatment-related issues are also substantial predictors of overall life quality.

  5. Building Data-Driven Pathways From Routinely Collected Hospital Data: A Case Study on Prostate Cancer

    PubMed Central

    Clark, Jeremy; Cooper, Colin S; Mills, Robert; Rayward-Smith, Victor J; de la Iglesia, Beatriz

    2015-01-01

    Background Routinely collected data in hospitals is complex, typically heterogeneous, and scattered across multiple Hospital Information Systems (HIS). This big data, created as a byproduct of health care activities, has the potential to provide a better understanding of diseases, unearth hidden patterns, and improve services and cost. The extent and uses of such data rely on its quality, which is not consistently checked, nor fully understood. Nevertheless, using routine data for the construction of data-driven clinical pathways, describing processes and trends, is a key topic receiving increasing attention in the literature. Traditional algorithms do not cope well with unstructured processes or data, and do not produce clinically meaningful visualizations. Supporting systems that provide additional information, context, and quality assurance inspection are needed. Objective The objective of the study is to explore how routine hospital data can be used to develop data-driven pathways that describe the journeys that patients take through care, and their potential uses in biomedical research; it proposes a framework for the construction, quality assessment, and visualization of patient pathways for clinical studies and decision support using a case study on prostate cancer. Methods Data pertaining to prostate cancer patients were extracted from a large UK hospital from eight different HIS, validated, and complemented with information from the local cancer registry. Data-driven pathways were built for each of the 1904 patients and an expert knowledge base, containing rules on the prostate cancer biomarker, was used to assess the completeness and utility of the pathways for a specific clinical study. Software components were built to provide meaningful visualizations for the constructed pathways. Results The proposed framework and pathway formalism enable the summarization, visualization, and querying of complex patient-centric clinical information, as well as the computation of quality indicators and dimensions. A novel graphical representation of the pathways allows the synthesis of such information. Conclusions Clinical pathways built from routinely collected hospital data can unearth information about patients and diseases that may otherwise be unavailable or overlooked in hospitals. Data-driven clinical pathways allow for heterogeneous data (ie, semistructured and unstructured data) to be collated over a unified data model and for data quality dimensions to be assessed. This work has enabled further research on prostate cancer and its biomarkers, and on the development and application of methods to mine, compare, analyze, and visualize pathways constructed from routine data. This is an important development for the reuse of big data in hospitals. PMID:26162314

  6. Relationship between the quality of children's handwriting and the Beery Buktenica developmental test of visuomotor integration after one year of writing tuition.

    PubMed

    Duiser, Ivonne H F; van der Kamp, John; Ledebt, Annick; Savelsbergh, Geert J P

    2014-04-01

    We examined whether the three subtests of the Beery Buktenica developmental test of visuomotor integration predicted quality of handwriting across and within groups of boys and girls classified as proficient, at risk or non-proficient writers according to the Concise Assessment Scale for Children's Handwriting. The Beery Buktenica developmental test of visuomotor integration and the Concise Assessment Scale for Children's Handwriting tests were administered to 240 grade 2 children. Proficient writers scored better on the visuomotor integration subtest than non-proficient writers, while proficient and at risk writers scored better than non-proficient writers on the motor coordination subtest. No differences were found on the visual perception subtest. Girls were more often classified as proficient writers than boys, and they scored better on the motor coordination subtest. Across groups, regression indicated that gender and both the visuomotor integration subtest and the motor coordination subtest were significant predictors for the quality of handwriting (i.e., accounted for 17% of the variance). After one year of writing tuition, the visuomotor integration subtest (and to a lesser extent the motor coordination subtest) but not the visual perception subtest significant relates to quality of children's handwriting as measured with the Concise Assessment Scale for Children's Handwriting. However, the relatively little variance explained also points to other abilities and/or task constraints that underlie quality of handwriting. © 2013 Occupational Therapy Australia.

  7. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism.

    PubMed

    Porcar, Esteban; Montalt, Juan Carlos; España-Gregori, Enrique; Peris-Martínez, Cristina

    2017-10-01

    To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  8. 'Silent voices' in health services research: ethnicity and socioeconomic variation in participation in studies of quality of life in childhood visual disability.

    PubMed

    Tadic, Valerie; Hamblion, Esther Louise; Keeley, Sarah; Cumberland, Phillippa; Lewando Hundt, Gillian; Rahi, Jugnoo Sangeeta

    2010-04-01

    Purpose. To investigate patterns of participation of visually impaired (VI) children and their families in health services research. Methods. The authors compared clinical and sociodemographic characteristics of children and their families who participated with those who did not participate in two studies of quality of life (QoL) of VI children. In Study 1, the authors interviewed VI children and adolescents, aged 10 to 15 years, about their vision-related quality of life (VRQoL) as the first phase of a program to develop a VRQoL instrument for this population. One hundred seven children with visual impairment (visual acuity in the better eye LogMar worse than 0.51) were invited to participate in the interviews. Study 2 investigated health-related quality of life (HRQoL) of VI children using an existing generic instrument, administered in a postal survey. 151 VI children and adolescents, aged 2 to 16 years, with hereditary retinal disorders were invited to participate in the survey. Results. The overall participation level was below 50%. In both studies, participants from white ethnic and more affluent socioeconomic backgrounds were overrepresented. Participation did not vary by age, sex, or clinical characteristics. Conclusions. The authors suggest that there are barriers to participation in child- and family-centered research on childhood visual disability for children from socioeconomically deprived or ethnic minority groups. They urge assessment and reporting of participation patterns in further health services research on childhood visual disability. Failure to recognize that there are "silent voices" is likely to have important implications for equitable and appropriate service planning and provision for VI children.

  9. pySeismicDQA: open source post experiment data quality assessment and processing

    NASA Astrophysics Data System (ADS)

    Polkowski, Marcin

    2017-04-01

    Seismic Data Quality Assessment is python based, open source set of tools dedicated for data processing after passive seismic experiments. Primary goal of this toolset is unification of data types and formats from different dataloggers necessary for further processing. This process requires additional data checks for errors, equipment malfunction, data format errors, abnormal noise levels, etc. In all such cases user needs to decide (manually or by automatic threshold) if data is removed from output dataset. Additionally, output dataset can be visualized in form of website with data availability charts and waveform visualization with earthquake catalog (external). Data processing can be extended with simple STA/LTA event detection. pySeismicDQA is designed and tested for two passive seismic experiments in central Europe: PASSEQ 2006-2008 and "13 BB Star" (2013-2016). National Science Centre Poland provided financial support for this work via NCN grant DEC-2011/02/A/ST10/00284.

  10. Stroke survivors' views and experiences on impact of visual impairment.

    PubMed

    Rowe, Fiona J

    2017-09-01

    We sought to determine stroke survivors' views on impact of stroke-related visual impairment to quality of life. Stroke survivors with visual impairment, more than 1 year post stroke onset, were recruited. Semistructured biographical narrative interviews were audio-recorded and transcribed verbatim. A thematic approach to analysis of the qualitative data was adopted. Transcripts were systematically coded using NVivo10 software. Thirty-five stroke survivors were interviewed across the UK: 16 females, 19 males; aged 20-75 years at stroke onset. Five qualitative themes emerged: "Formal care," "Symptoms and self," "Adaptations," "Daily life," and "Information." Where visual problems existed, they were often not immediately recognized as part of the stroke syndrome and attributed to other causes such as migraine. Many participants did not receive early vision assessment or treatment for their visual problems. Visual problems included visual field loss, double vision, and perceptual problems. Impact of visual problems included loss in confidence, being a burden to others, increased collisions/accidents, and fear of falling. They made many self-identified adaptations to compensate for visual problems: magnifiers, large print, increased lighting, use of white sticks. There was a consistent lack of support and provision of information about visual problems. Poststroke visual impairment causes considerable impact to daily life which could be substantially improved by simple measures including early formal visual assessment, management and advice on adaptive strategies and self-management options. Improved education about poststroke visual impairment for the public and clinicians could aid earlier diagnosis of visual impairments.

  11. Health Inequalities Associated with Post-Stroke Visual Impairment in the United Kingdom and Ireland: A Systematic Review

    PubMed Central

    Hanna, K. L.; Rowe, F. J.

    2017-01-01

    ABSTRACT The aim of this study was to report on the health inequalities facing stroke survivors with visual impairments as described in the current literature. A systemic review of the literature was conducted to investigate the potential health inequalities facing stroke survivors with subsequent visual impairments. A quality-of-evidence and risk-of-bias assessment was conducted for each of the included articles using the appropriate tool dependent on the type of article. Only four articles discussed health inequalities affecting stroke survivors with visual impairment specifically. A further 23 articles identified health inequalities after stroke, and 38 reported on health inequalities within the visually impaired UK or Irish population. Stroke survivors with visual impairment face inconsistency in eye care provision nationally, along with variability in the assessment and management of visual disorders. The subgroups identified as most at risk were females; black ethnicity; lower socioeconomic status; older age; and those with lower education attainment. The issue of inconsistent service provision for this population must be addressed in future research. Further research must be conducted in order to firmly establish whether or not stroke survivors are at risk of the aforementioned sociodemographic and economic inequalities. PMID:28512502

  12. Functional improvements following the use of the NVT Vision Rehabilitation program for patients with hemianopia following stroke.

    PubMed

    Hayes, Allison; Chen, Celia S; Clarke, Gayle; Thompson, Annette

    2012-01-01

    The incidence of visual deficits following stroke ranges from 20%-68% and has significant impact on activities of daily living. The NVT system is a compensatory visual scanning training program that consists of combined static and mobility training and transfer to activities of daily living. The study aims to evaluate functional changes following the NVT program for people who have homonymous hemianopia (HH) following stroke. Interventional case series of 13 consecutive participants with HH undergoing NVT vision rehabilitation. The primary outcome measure was the number of targets missed on a standardized Mobility Assessment Course (MAC). Other outcome measures included assessment of visual scanning, vision specific Quality of Life questionnaires and reading performance. The average number of targets (sd) missed on the MAC course was 39.6 ± 20.9% before intervention, 27.5 ± 16.3% immediately post intervention and 20.8 ± 15.5% at 3 months post rehabilitation. The study showed a statistically significant trend in improvement in mobility related subscales of National Eye Institute Visual Function Questionnaire-NEI VFQ-25 (p=0.003) and the Veteran Affairs Low Vision Visual Function Questionnaire-VA LVFQ-48 (p=0.036) at 3 months post rehabilitation. The NVT intervention resulted in functional improvements in mobility post rehabilitation. The NVT training showed improvement in vision specific quality of life. There is a need for standardised vision therapy intervention, in conjunction with existing rehabilitation services, for patients with stroke and traumatic brain injury.

  13. Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

    NASA Technical Reports Server (NTRS)

    Vu, Amanda Cadao; Raghunandan, Sneha; Vyas, Ruchi; Radhakrishnan, Krishnan; Taibbi, Giovanni; Vizzeri, Gianmarco; Grant, Maria; Chalam, Kakarla; Parsons-Wingerter, Patricia

    2015-01-01

    Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

  14. Enhancing VELMA's Watershed Delineation and Performance with Ancillary Stream Data

    EPA Science Inventory

    VELMA (Visualizing Ecosystems for Land Management Assessment) is a hydro-ecological landscape disturbance model developed to predict the effectiveness of alternative green infrastructure scenarios for protecting water quality, and also to estimate potential ecosystem service co-b...

  15. Impact of Retinitis Pigmentosa on Quality of Life, Mental Health, and Employment Among Young Adults.

    PubMed

    Chaumet-Riffaud, Anne Elisabeth; Chaumet-Riffaud, Philippe; Cariou, Anaelle; Devisme, Céline; Audo, Isabelle; Sahel, José-Alain; Mohand-Said, Saddek

    2017-05-01

    To determine the relationship between visual function and quality of life, education, mental health, and employment among young adults with retinitis pigmentosa (RP). Cross-sectional study. Inclusion of 148 patients (mean age 38.2 ± 7.1 years) diagnosed with RP, living in France. Quality of life was assessed using the National Eye Institute Visual Function Questionnaire (VFQ-25), mental state with the Hospital and Anxiety and Depression Scale (HADS), and employment with a specifically designed questionnaire. Limited visual impairment was noted in 22.3%, low vision in 29.7%, and legal blindness in 48.0%. There was a correlation between quality-of-life scores and residual visual field (P < .0001). Mental health scores were suggestive of anxiety in 36.5% and depression in 15.5%. The rates did not increase with disability level (P = .738, P = .134). The percentage of subjects with higher education did not significantly decrease with disability level (P = .113). The employment rate did not significantly decrease with disability level (P = .276). It was lower in subjects reporting depression (P = .0414). Self-rated impact of RP on employment increased with disability level (P = .02642). Our results differ from previous results showing lower education rates and employment rates in young adults with RP. Further research is warranted focusing on the impact of mental health, education, workplace conditions, and employment aids on employment rate vs age- and education-matched normally sighted controls to guide visual disability strategies in RP. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Quality assessment for color reproduction using a blind metric

    NASA Astrophysics Data System (ADS)

    Bringier, B.; Quintard, L.; Larabi, M.-C.

    2007-01-01

    This paper deals with image quality assessment. This field plays nowadays an important role in various image processing applications. Number of objective image quality metrics, that correlate or not, with the subjective quality have been developed during the last decade. Two categories of metrics can be distinguished, the first with full-reference and the second with no-reference. Full-reference metric tries to evaluate the distortion introduced to an image with regards to the reference. No-reference approach attempts to model the judgment of image quality in a blind way. Unfortunately, the universal image quality model is not on the horizon and empirical models established on psychophysical experimentation are generally used. In this paper, we focus only on the second category to evaluate the quality of color reproduction where a blind metric, based on human visual system modeling is introduced. The objective results are validated by single-media and cross-media subjective tests.

  17. Standardized Uptake Value Ratio-Independent Evaluation of Brain Amyloidosis.

    PubMed

    Chincarini, Andrea; Sensi, Francesco; Rei, Luca; Bossert, Irene; Morbelli, Silvia; Guerra, Ugo Paolo; Frisoni, Giovanni; Padovani, Alessandro; Nobili, Flavio

    2016-10-18

    The assessment of in vivo18F images targeting amyloid deposition is currently carried on by visual rating with an optional quantification based on standardized uptake value ratio (SUVr) measurements. We target the difficulties of image reading and possible shortcomings of the SUVr methods by validating a new semi-quantitative approach named ELBA. ELBA involves a minimal image preprocessing and does not rely on small, specific regions of interest (ROIs). It evaluates the whole brain and delivers a geometrical/intensity score to be used for ranking and dichotomic assessment. The method was applied to adniimages 18F-florbetapir images from the ADNI database. Five expert readers provided visual assessment in blind and open sessions. The longitudinal trend and the comparison to SUVr measurements were also evaluated. ELBA performed with area under the roc curve (AUC) = 0.997 versus the visual assessment. The score was significantly correlated to the SUVr values (r = 0.86, p < 10-4). The longitudinal analysis estimated a test/retest error of ≃2.3%. Cohort and longitudinal analysis suggests that the ELBA method accurately ranks the brain amyloid burden. The expert readers confirmed its relevance in aiding the visual assessment in a significant number (85) of difficult cases. Despite the good performance, poor and uneven image quality constitutes the major limitation.

  18. Visual Attention and Applications in Multimedia Technologies

    PubMed Central

    Le Callet, Patrick; Niebur, Ernst

    2013-01-01

    Making technological advances in the field of human-machine interactions requires that the capabilities and limitations of the human perceptual system are taken into account. The focus of this report is an important mechanism of perception, visual selective attention, which is becoming more and more important for multimedia applications. We introduce the concept of visual attention and describe its underlying mechanisms. In particular, we introduce the concepts of overt and covert visual attention, and of bottom-up and top-down processing. Challenges related to modeling visual attention and their validation using ad hoc ground truth are also discussed. Examples of the usage of visual attention models in image and video processing are presented. We emphasize multimedia delivery, retargeting and quality assessment of image and video, medical imaging, and the field of stereoscopic 3D images applications. PMID:24489403

  19. Determinants of the Overall Quality of Life of Older Persons Who Have Difficulty Seeing: The Importance of the Ability to Get Around

    ERIC Educational Resources Information Center

    La Grow, Steven; Yeung, Polly; Towers, Andrew; Alpass, Fiona; Stephens, Christine

    2011-01-01

    A model of vision rehabilitation that assumes that functional ability will affect the emotional and psychosocial adjustment of older persons with visual impairments, and ultimately their quality of life, was assessed using structured equation modeling. The proposed model was upheld. In addition, the ability to get around was found to contribute to…

  20. Pictorial Representation of Illness and Self Measure (PRISM): A novel visual instrument to measure quality of life in dermatological inpatients.

    PubMed

    Mühleisen, Beda; Büchi, Stefan; Schmidhauser, Simone; Jenewein, Josef; French, Lars E; Hofbauer, Günther F L

    2009-07-01

    To validate the PRISM (Pictorial Representation of Illness and Self Measure) tool, a novel visual instrument, for the assessment of health-related quality of life in dermatological inpatients compared with the Dermatology Life Quality Index (DLQI) and the Skindex-29 questionnaires and to report qualitative information on PRISM. In an open longitudinal study, PRISM and Skindex-29 and DLQI questionnaires were completed and HRQOL measurements compared. Academic dermatological inpatient ward. The study population comprised 227 sequential dermatological inpatients on admission. Patients completed the PRISM tool and the Skindex-29 and DLQI questionnaires at admission and discharge. PRISM Self-Illness Separation (SIS) score; Skindex-29 and DLQI scores; and qualitative PRISM information by Mayring inductive qualitative context analysis. The PRISM scores correlated well with those from the Skindex-29 (rho = 0.426; P < .001) and DLQI (rho = 0.304; P < .001) questionnaires. Between PRISM and Skindex-29 scores, the highest correlations were for dermatitis (rho = 0.614) and leg ulcer (rho = 0.554), and between PRISM and DLQI scores, the highest correlations were for psoriasis (rho = 0.418) and tumor (rho = 0.399). The PRISM tool showed comparable or higher sensitivity than quality of life questionnaires to assess changes in the burden of suffering during hospitalization. Inductive qualitative context analysis revealed impairment of adjustment and self-image as major aspects. Patients overall expected symptomatic and functional improvement. In patients with psoriasis and leg ulcers, many expected no treatment benefit. The PRISM tool proved to be convenient and reliable for health-related quality of life assessment, applicable for a wide range of skin diseases, and correlated with DLQI and Skindex-29 scores. With the PRISM tool, free-text answers allow for the assessment of individual information and potentially customized therapeutic approaches.

  1. An Information-Theoretic-Cluster Visualization for Self-Organizing Maps.

    PubMed

    Brito da Silva, Leonardo Enzo; Wunsch, Donald C

    2018-06-01

    Improved data visualization will be a significant tool to enhance cluster analysis. In this paper, an information-theoretic-based method for cluster visualization using self-organizing maps (SOMs) is presented. The information-theoretic visualization (IT-vis) has the same structure as the unified distance matrix, but instead of depicting Euclidean distances between adjacent neurons, it displays the similarity between the distributions associated with adjacent neurons. Each SOM neuron has an associated subset of the data set whose cardinality controls the granularity of the IT-vis and with which the first- and second-order statistics are computed and used to estimate their probability density functions. These are used to calculate the similarity measure, based on Renyi's quadratic cross entropy and cross information potential (CIP). The introduced visualizations combine the low computational cost and kernel estimation properties of the representative CIP and the data structure representation of a single-linkage-based grouping algorithm to generate an enhanced SOM-based visualization. The visual quality of the IT-vis is assessed by comparing it with other visualization methods for several real-world and synthetic benchmark data sets. Thus, this paper also contains a significant literature survey. The experiments demonstrate the IT-vis cluster revealing capabilities, in which cluster boundaries are sharply captured. Additionally, the information-theoretic visualizations are used to perform clustering of the SOM. Compared with other methods, IT-vis of large SOMs yielded the best results in this paper, for which the quality of the final partitions was evaluated using external validity indices.

  2. Vision in a phase 3 trial of natalizumab for multiple sclerosis: relation to disability and quality of life.

    PubMed

    Chahin, Salim; Balcer, Laura J; Miller, Deborah M; Zhang, Annie; Galetta, Steven L

    2015-03-01

    Low-contrast visual acuity (LCVA), a sensitive measure of visual function in multiple sclerosis (MS), demonstrated treatment effects as a secondary outcome measure in the Phase 3 trial of natalizumab, AFFIRM. In these posttrial analyses, we studied the relation of visual function to quality of life (QOL), magnetic resonance imaging (MRI) measures, and Expanded Disability Status Scale (EDSS) scores. At baseline and at 52 and 104 weeks in AFFIRM, patients underwent binocular testing of LCVA (1.25% and 2.5% contrast) and high-contrast visual acuity (HCVA). Vision-specific QOL was assessed by the Impact of Visual Impairment Scale (IVIS), whereas the SF-36 Health Survey and Visual Analog Scale were administered as generic QOL measures and the EDSS as a measure of neurologic impairment. Among QOL measures, IVIS scores showed the most significant correlations with visual dysfunction at all time points in the trial (r= -0.25 to -0.45, P < 0.0001 for LCVA and HCVA). Higher MRI T1- and T2-lesion volumes were also associated with worse vision scores at all time points (P < 0.0001). Clinically meaningful worsening (progression) of LCVA was noted in substantial proportions of patients in AFFIRM and was prevalent even among those without EDSS progression over 2 years (21.9% with LCVA progression at 2.5% contrast; 26.2% at 1.25% contrast). HCVA worsened in only 3.7% of patients without EDSS progression. Loss of visual function, particularly as measured by LCVA, was common in AFFIRM, occurring in >20% of patients. Both LCVA and HCVA scores reflect vision-specific aspects of QOL, but LCVA provides information about disability progression not entirely captured by the EDSS. Vision represents a key dimension of outcome assessment for MS and adds valuable information on disability and QOL that can be useful to clinicians.

  3. Testing vision with angular and radial multifocal designs using Adaptive Optics.

    PubMed

    Vinas, Maria; Dorronsoro, Carlos; Gonzalez, Veronica; Cortes, Daniel; Radhakrishnan, Aiswaryah; Marcos, Susana

    2017-03-01

    Multifocal vision corrections are increasingly used solutions for presbyopia. In the current study we have evaluated, optically and psychophysically, the quality provided by multizone radial and angular segmented phase designs. Optical and relative visual quality were evaluated using 8 subjects, testing 6 phase designs. Optical quality was evaluated by means of Visual Strehl-based-metrics (VS). The relative visual quality across designs was obtained through a psychophysical paradigm in which images viewed through 210 pairs of phase patterns were perceptually judged. A custom-developed Adaptive Optics (AO) system, including a Hartmann-Shack sensor and an electromagnetic deformable mirror, to measure and correct the eye's aberrations, and a phase-only reflective Spatial Light Modulator, to simulate the phase designs, was developed for this study. The multizone segmented phase designs had 2-4 zones of progressive power (0 to +3D) in either radial or angular distributions. The response of an "ideal observer" purely responding on optical grounds to the same psychophysical test performed on subjects was calculated from the VS curves, and compared with the relative visual quality results. Optical and psychophysical pattern-comparison tests showed that while 2-zone segmented designs (angular & radial) provided better performance for far and near vision, 3- and 4-zone segmented angular designs performed better for intermediate vision. AO-correction of natural aberrations of the subjects modified the response for the different subjects but general trends remained. The differences in perceived quality across the different multifocal patterns are, in a large extent, explained by optical factors. AO is an excellent tool to simulate multifocal refractions before they are manufactured or delivered to the patient, and to assess the effects of the native optics to their performance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. PRIDE Inspector Toolsuite: Moving Toward a Universal Visualization Tool for Proteomics Data Standard Formats and Quality Assessment of ProteomeXchange Datasets.

    PubMed

    Perez-Riverol, Yasset; Xu, Qing-Wei; Wang, Rui; Uszkoreit, Julian; Griss, Johannes; Sanchez, Aniel; Reisinger, Florian; Csordas, Attila; Ternent, Tobias; Del-Toro, Noemi; Dianes, Jose A; Eisenacher, Martin; Hermjakob, Henning; Vizcaíno, Juan Antonio

    2016-01-01

    The original PRIDE Inspector tool was developed as an open source standalone tool to enable the visualization and validation of mass-spectrometry (MS)-based proteomics data before data submission or already publicly available in the Proteomics Identifications (PRIDE) database. The initial implementation of the tool focused on visualizing PRIDE data by supporting the PRIDE XML format and a direct access to private (password protected) and public experiments in PRIDE.The ProteomeXchange (PX) Consortium has been set up to enable a better integration of existing public proteomics repositories, maximizing its benefit to the scientific community through the implementation of standard submission and dissemination pipelines. Within the Consortium, PRIDE is focused on supporting submissions of tandem MS data. The increasing use and popularity of the new Proteomics Standards Initiative (PSI) data standards such as mzIdentML and mzTab, and the diversity of workflows supported by the PX resources, prompted us to design and implement a new suite of algorithms and libraries that would build upon the success of the original PRIDE Inspector and would enable users to visualize and validate PX "complete" submissions. The PRIDE Inspector Toolsuite supports the handling and visualization of different experimental output files, ranging from spectra (mzML, mzXML, and the most popular peak lists formats) and peptide and protein identification results (mzIdentML, PRIDE XML, mzTab) to quantification data (mzTab, PRIDE XML), using a modular and extensible set of open-source, cross-platform libraries. We believe that the PRIDE Inspector Toolsuite represents a milestone in the visualization and quality assessment of proteomics data. It is freely available at http://github.com/PRIDE-Toolsuite/. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  5. PRIDE Inspector Toolsuite: Moving Toward a Universal Visualization Tool for Proteomics Data Standard Formats and Quality Assessment of ProteomeXchange Datasets*

    PubMed Central

    Perez-Riverol, Yasset; Xu, Qing-Wei; Wang, Rui; Uszkoreit, Julian; Griss, Johannes; Sanchez, Aniel; Reisinger, Florian; Csordas, Attila; Ternent, Tobias; del-Toro, Noemi; Dianes, Jose A.; Eisenacher, Martin; Hermjakob, Henning; Vizcaíno, Juan Antonio

    2016-01-01

    The original PRIDE Inspector tool was developed as an open source standalone tool to enable the visualization and validation of mass-spectrometry (MS)-based proteomics data before data submission or already publicly available in the Proteomics Identifications (PRIDE) database. The initial implementation of the tool focused on visualizing PRIDE data by supporting the PRIDE XML format and a direct access to private (password protected) and public experiments in PRIDE. The ProteomeXchange (PX) Consortium has been set up to enable a better integration of existing public proteomics repositories, maximizing its benefit to the scientific community through the implementation of standard submission and dissemination pipelines. Within the Consortium, PRIDE is focused on supporting submissions of tandem MS data. The increasing use and popularity of the new Proteomics Standards Initiative (PSI) data standards such as mzIdentML and mzTab, and the diversity of workflows supported by the PX resources, prompted us to design and implement a new suite of algorithms and libraries that would build upon the success of the original PRIDE Inspector and would enable users to visualize and validate PX “complete” submissions. The PRIDE Inspector Toolsuite supports the handling and visualization of different experimental output files, ranging from spectra (mzML, mzXML, and the most popular peak lists formats) and peptide and protein identification results (mzIdentML, PRIDE XML, mzTab) to quantification data (mzTab, PRIDE XML), using a modular and extensible set of open-source, cross-platform libraries. We believe that the PRIDE Inspector Toolsuite represents a milestone in the visualization and quality assessment of proteomics data. It is freely available at http://github.com/PRIDE-Toolsuite/. PMID:26545397

  6. Quality of life in patients with visual impairment in Ibadan: a clinical study in primary care.

    PubMed

    Adigun, Kehinde; Oluleye, Tunji S; Ladipo, Modupe Ma; Olowookere, Samuel Anu

    2014-01-01

    Visual function is important for optimal orientation in functional and social life, and has an effect on physical and emotional well-being. Visual impairment, therefore, leads to restrictions in all aspects of daily living and is related to quality of life. The aim of this study was to provide information on the causes of visual impairment in patients presenting to their family physician, the spectrum of impairment, and its impact on quality of life for these patients. This descriptive cross-sectional study of 375 adult patients with ocular symptoms was performed in the general outpatient department of the University College Hospital, Ibadan, from July to September, 2009. After checking their presenting visual acuity, the patients were interviewed using the Vision-Related Quality of Life questionnaire to determine the impact of visual impairment on their quality of life. Ophthalmic examinations were performed to determine the causes of visual impairment. The results were analyzed using proportions and percentages. The main causes of visual impairment were cataracts (58.7%), refractive error (19.4%), and glaucoma (2.9%). Visual impairment was found to be associated with advancing age, low education, and unemployment (P<0.001). Most patients (85.1%) were found to have good quality of life overall. Quality of life was found to be poor in the domains of visual function (64.2%) and social interaction (50.9%). Quality of life was found to be related to the degree of visual impairment, ie, blind patients reported poor quality of life (41.4%) when compared with those having low vision (8.6%) or near normal vision (2.4%, P<0.001). This study identified poor quality of life in patients with a higher degree of visual impairment. Family physicians need to identify these visually impaired patients early and make timely referrals.

  7. Visual neglect following stroke: current concepts and future focus.

    PubMed

    Ting, Darren S J; Pollock, Alex; Dutton, Gordon N; Doubal, Fergus N; Ting, Daniel S W; Thompson, Michelle; Dhillon, Baljean

    2011-01-01

    Visual neglect is a common, yet frequently overlooked, neurological disorder following stroke characterized by a deficit in attention and appreciation of stimuli on the contralesional side of the body. It has a profound functional impact on affected individuals. A assessment and management of this condition are hindered, however, by the lack of professional awareness and clinical guidelines. Recent evidence suggests that the underlying deficit in visual attention is due to a disrupted internalized representation of the outer world rather than a disorder of sensory inputs. Dysfunction of the cortical domains and white-matter tracts, as well as inter-hemispheric imbalance, have been implicated in the various manifestations of visual neglect. Optimal diagnosis requires careful history-taking from the patient, family, and friends, in addition to clinical assessment with the line bisection test, the star cancellation test, and the Catherine Bergego Scale. Early recognition and prompt rehabilitation employing a multidisciplinary approach is desirable. Although no treatment has been definitively shown to be of benefit, those with promise include prism adaptation, visual scanning therapy, and virtual reality-based techniques. Further high quality research to seek optimum short- and long-term rehabilitative strategies for visual neglect is required. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Quality assessment of color images based on the measure of just noticeable color difference

    NASA Astrophysics Data System (ADS)

    Chou, Chun-Hsien; Hsu, Yun-Hsiang

    2014-01-01

    Accurate assessment on the quality of color images is an important step to many image processing systems that convey visual information of the reproduced images. An accurate objective image quality assessment (IQA) method is expected to give the assessment result highly agreeing with the subjective assessment. To assess the quality of color images, many approaches simply apply the metric for assessing the quality of gray scale images to each of three color channels of the color image, neglecting the correlation among three color channels. In this paper, a metric for assessing color images' quality is proposed, in which the model of variable just-noticeable color difference (VJNCD) is employed to estimate the visibility thresholds of distortion inherent in each color pixel. With the estimated visibility thresholds of distortion, the proposed metric measures the average perceptible distortion in terms of the quantized distortion according to the perceptual error map similar to that defined by National Bureau of Standards (NBS) for converting the color difference enumerated by CIEDE2000 to the objective score of perceptual quality assessment. The perceptual error map in this case is designed for each pixel according to the visibility threshold estimated by the VJNCD model. The performance of the proposed metric is verified by assessing the test images in the LIVE database, and is compared with those of many well-know IQA metrics. Experimental results indicate that the proposed metric is an effective IQA method that can accurately predict the image quality of color images in terms of the correlation between objective scores and subjective evaluation.

  9. Factors associated with vision-related quality of life among the adult population living in Nagorno Karabagh.

    PubMed

    Harutyunyan, T; Giloyan, A; Petrosyan, V

    2017-12-01

    Visual impairment and blindness are major public health problems causing significant suffering, disability, loss of productivity, and diminishing quality of life for millions of people. This study explored the factors associated with the overall vision-related quality of life (VRQoL) and its different domains in the adult population of Nagorno Karabakh and assessed the independent contribution of specific eye diseases to VRQoL. A cross-sectional study. We conducted interviewer-administered survey along with free eye screenings among adult residents of Hadrut and Martuni regions of Nagorno Karabakh (Artsakh) in 2014-2015. The study questionnaire included questions about sociodemographic characteristics, non-communicable diseases, use of eye care services, visual acuity, eye diseases, and VRQoL. National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25) was used to assess VRQoL. In total, 531 adults participated in the study. The mean age of participants was 60.1 years (standard deviation [SD] = 13.7), ranging from 18 to 90 years. The majority of participants were female (71.4%). The most frequently diagnosed eye disorder was cataract (33.8%). The prevalence of moderate and severe visual impairment was 7.0% and 0.8%, respectively. Almost 2.8% (15) of participants were blind. The mean global score of VFQ-25 in all study participants was 71.1 ± 19.28 (SD), whereas the mean global scores of VFQ-25 among not visually impaired, visually impaired, and blind participants were 74.0 ± 16.47 (SD), 51.7 ± 21.77 (SD), and 30.9 ± 20.2 (SD), respectively. In the adjusted linear regression model having moderate/severe visual impairment or blindness, age, socio-economic status, and having eye diseases such as glaucoma and cataract were significantly associated with VFQ-25 global score. The subscales of near vision, distance vision, peripheral vision, role difficulties, and mental health had significant associations with severe/moderate visual impairment in the adjusted analysis. After adjusting for visual impairment and demographic variables, participants with cataract and glaucoma were found to have statistically significant lower subscale scores than those without eye disease. Our data suggest that visual impairment was associated with lower scores of VRQoL. The strength of that association correlated with the increase in the level of visual impairment (from moderate/severe impairment to blindness). VRQoL was also shown to be affected by age, socio-economic status, and having eye diseases such as glaucoma and cataract. Further actions of remediation of visual impairment in this population are warranted. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  10. Developing and Evaluating a Target-Background Similarity Metric for Camouflage Detection

    PubMed Central

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Liu, Bor-Shong

    2014-01-01

    Background Measurement of camouflage performance is of fundamental importance for military stealth applications. The goal of camouflage assessment algorithms is to automatically assess the effect of camouflage in agreement with human detection responses. In a previous study, we found that the Universal Image Quality Index (UIQI) correlated well with the psychophysical measures, and it could be a potentially camouflage assessment tool. Methodology In this study, we want to quantify the camouflage similarity index and psychophysical results. We compare several image quality indexes for computational evaluation of camouflage effectiveness, and present the results of an extensive human visual experiment conducted to evaluate the performance of several camouflage assessment algorithms and analyze the strengths and weaknesses of these algorithms. Significance The experimental data demonstrates the effectiveness of the approach, and the correlation coefficient result of the UIQI was higher than those of other methods. This approach was highly correlated with the human target-searching results. It also showed that this method is an objective and effective camouflage performance evaluation method because it considers the human visual system and image structure, which makes it consistent with the subjective evaluation results. PMID:24498310

  11. Piloted Simulation Assessment of a High-Speed Civil Transport Configuration. [conducted with the Langley six-degree-of-freedom Visual Motion Simulator

    NASA Technical Reports Server (NTRS)

    Jackson, E. Bruce; Raney, David L.; Glaab, Louis J.; Derry, Stephen D.

    2002-01-01

    An assessment of a proposed configuration of a high-speed civil transport was conducted by using NASA and industry research pilots. The assessment was conducted to evaluate operational aspects of the configuration from a pilot's perspective, with the primary goal being to identify potential deficiencies in the configuration. The configuration was evaluated within and at the limits of the design operating envelope to determine the suitability of the configuration to maneuver in a typical mission as well as in emergency or envelope-limit conditions. The Cooper-Harper rating scale was used to evaluate the flying qualities of the configuration. A summary flying qualities metric was also calculated. The assessment was performed in the Langley six-degree-of-freedom Visual Motion Simulator. The effect of a restricted cockpit field-of-view due to obstruction by the vehicle nose was not included in this study. Tasks include landings, takeoffs, climbs, descents, overspeeds, coordinated turns, and recoveries from envelope limit excursions. Emergencies included engine failures, loss of stability augmentation, engine inlet unstarts, and emergency descents. Minimum control speeds and takeoff decision, rotation, and safety speeds were also determined.

  12. Human Visual System-Based Fundus Image Quality Assessment of Portable Fundus Camera Photographs.

    PubMed

    Wang, Shaoze; Jin, Kai; Lu, Haitong; Cheng, Chuming; Ye, Juan; Qian, Dahong

    2016-04-01

    Telemedicine and the medical "big data" era in ophthalmology highlight the use of non-mydriatic ocular fundus photography, which has given rise to indispensable applications of portable fundus cameras. However, in the case of portable fundus photography, non-mydriatic image quality is more vulnerable to distortions, such as uneven illumination, color distortion, blur, and low contrast. Such distortions are called generic quality distortions. This paper proposes an algorithm capable of selecting images of fair generic quality that would be especially useful to assist inexperienced individuals in collecting meaningful and interpretable data with consistency. The algorithm is based on three characteristics of the human visual system--multi-channel sensation, just noticeable blur, and the contrast sensitivity function to detect illumination and color distortion, blur, and low contrast distortion, respectively. A total of 536 retinal images, 280 from proprietary databases and 256 from public databases, were graded independently by one senior and two junior ophthalmologists, such that three partial measures of quality and generic overall quality were classified into two categories. Binary classification was implemented by the support vector machine and the decision tree, and receiver operating characteristic (ROC) curves were obtained and plotted to analyze the performance of the proposed algorithm. The experimental results revealed that the generic overall quality classification achieved a sensitivity of 87.45% at a specificity of 91.66%, with an area under the ROC curve of 0.9452, indicating the value of applying the algorithm, which is based on the human vision system, to assess the image quality of non-mydriatic photography, especially for low-cost ophthalmological telemedicine applications.

  13. Measuring outcomes of cataract surgery using the Quality of Well-Being Scale and VF-14 Visual Function Index.

    PubMed

    Rosen, Peter N; Kaplan, Robert M; David, Kristen

    2005-02-01

    To evaluate the validity and responsiveness of the self-administered Quality of Well-Being Scale (QWB-SA) and the 14-item Visual Function Index (VF-14) to assess patients having cataract surgery. Large Southern California health maintenance organization. This study comprised 233 adults who had uneventful small-incision (< 3.0 mm) phacoemulsification cataract extraction under local anesthesia. Patients were assessed before surgery as well as 4 to 6 weeks and 4 months after surgery using the QWB-SA and the VF-14. Postoperatively, patients reported significant improvements on QWB-SA (P < .005) and VF-14 (P < .001) measures. Those grouped by visual acuity in the operated eye and unoperated eye and first-eye surgery or second-eye surgery had significant changes in VF-14 results (P < .001). Improvements on the QWB-SA were significant except when the preoperative visual acuity was better than 20/40 in the operated eye or 20/50 in the unoperated eye and when patients had first-eye surgery. The vision-specific VF-14 was more sensitive to improvements after surgery than the more general QWB-SA. Both demonstrated a greater magnitude of change with lower baseline scores and correlated significantly with self-reported satisfaction and trouble with vision. Both the utility-based generic QWB-SA and disease-specific VF-14 profile were responsive to changes in quality of life after cataract surgery. The VF-14 was more sensitive to change but cannot be used for comparison across disease states or for policy analysis. The QWB-SA can be used to estimate the cost/utility of cataract surgery.

  14. Towards a Visual Quality Metric for Digital Video

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.

    1998-01-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics. In previous work, we have developed visual quality metrics for evaluating, controlling, and optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. The challenge of video quality metrics is to extend these simplified models to temporal signals as well. In this presentation I will discuss a number of the issues that must be resolved in the design of effective video quality metrics. Among these are spatial, temporal, and chromatic sensitivity and their interactions, visual masking, and implementation complexity. I will also touch on the question of how to evaluate the performance of these metrics.

  15. A pre- and post-treatment evaluation of vision-related quality of life in uveitis

    PubMed Central

    Rathinam, SR

    2008-01-01

    Aim: To study the effect of treatment on vision-related quality of life (VR-QOL) in uveitis patients. Materials and Methods: Interviewer-administered questionnaire-based evaluation of visual function and VR-QOL in Tamil-speaking adult patients with active uveitis at presentation and follow-up by the same interviewer. Results: Ninety-eight patients participated in this study. There was a statistically significant improvement in VR-QOL in all the scales following treatment (P < 0.001). Patients with chronic uveitis showed better improvement upon treatment than patients with acute uveitis. The visual symptoms scale showed moderate gains following treatment (effect size 0.56). Persons with bilateral disease had poorer mean scores compared to those with unilateral disease. Visual acuity was closely correlated with VR-QOL scores. Conclusion: The VR-QOL measurement has shown that it is sensitive to demonstrate the problems of patients with uveitis irrespective of their demographic profile. The scores improved significantly in patients with uveitis following treatment and have shown close correlation to visual acuity thus demonstrating that VR-QOL is effective in assessing the response to treatment. PMID:18579990

  16. Image gathering and coding for digital restoration: Information efficiency and visual quality

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; John, Sarah; Mccormick, Judith A.; Narayanswamy, Ramkumar

    1989-01-01

    Image gathering and coding are commonly treated as tasks separate from each other and from the digital processing used to restore and enhance the images. The goal is to develop a method that allows us to assess quantitatively the combined performance of image gathering and coding for the digital restoration of images with high visual quality. Digital restoration is often interactive because visual quality depends on perceptual rather than mathematical considerations, and these considerations vary with the target, the application, and the observer. The approach is based on the theoretical treatment of image gathering as a communication channel (J. Opt. Soc. Am. A2, 1644(1985);5,285(1988). Initial results suggest that the practical upper limit of the information contained in the acquired image data range typically from approximately 2 to 4 binary information units (bifs) per sample, depending on the design of the image-gathering system. The associated information efficiency of the transmitted data (i.e., the ratio of information over data) ranges typically from approximately 0.3 to 0.5 bif per bit without coding to approximately 0.5 to 0.9 bif per bit with lossless predictive compression and Huffman coding. The visual quality that can be attained with interactive image restoration improves perceptibly as the available information increases to approximately 3 bifs per sample. However, the perceptual improvements that can be attained with further increases in information are very subtle and depend on the target and the desired enhancement.

  17. Curriculum Development and Evaluation in the Arts.

    ERIC Educational Resources Information Center

    Day, Michael D.

    1980-01-01

    In this paper some of the distinctive qualities of the arts are reviewed and implications for curriculum and evaluation are discussed. For this discussion the visual arts serve as the exemplar from the several arts for discussion of subject content, learning, and assessment. (Author)

  18. [Cataract surgery and its impact on balance and autonomy in elderly].

    PubMed

    Raynal, M; Aupy, B; Jahidi, A; Ettien, D; Le Page, P; Briche, T; Kossowski, M; Pailllaud, E

    2009-01-01

    Cataract is a major cause of visual impairment among elderly. Cataract surgery improves visual afferencies and can have an impact on balance. The present study assessed the impact of cataract surgery upon balance and autonomy in elderly. We realized clinical examinations and objective tests the day before surgery and 2-months later. The initial cohort consisted of 66 patients that had to undergo a cataract surgery. Their mean age was 79 +/- 0.5. For logistic reasons, only 33 patients have been completely evaluated before and after surgery. Each patient underwent a history and examination that have assessed autonomy, walking, visual and then cochleo-vestibular functions including bone vibratory test and dynamic computerized posturography (Equitest). After 2 months, cataract surgery had no incidence on balance. The fear of falling has stayed the same whereas the number of falls has been noticeably reduced by surgery. The overall score of Equitest has shown an increase in visual dependence after surgery. Although cataract surgery has no incidence on autonomy, it may improve the quality of life among older people by leisure activities recovery. An early physical rehabilitation facilitated by visual improvement after surgery can also prevent visual dependence and autonomy loss. We recommend vestibular rehabilitation in elderly with major visual dependence.

  19. Anti-malarial drug quality in Lagos and Accra - a comparison of various quality assessments

    PubMed Central

    2010-01-01

    Background Two major cities in West Africa, Accra, the capital of Ghana, and Lagos, the largest city of Nigeria, have significant problems with substandard pharmaceuticals. Both have actively combated the problem in recent years, particularly by screening products on the market using the Global Pharma Health Fund e.V. Minilab® protocol. Random sampling of medicines from the two cities at least twice over the past 30 months allows a tentative assessment of whether improvements in drug quality have occurred. Since intelligence provided by investigators indicates that some counterfeit producers may be adapting products to pass Minilab tests, the results are compared with those from a Raman spectrometer and discrepancies are discussed. Methods Between mid-2007 and early-2010, samples of anti-malarial drugs were bought covertly from pharmacies in Lagos on three different occasions (October 2007, December 2008, February 2010), and from pharmacies in Accra on two different occasions (October 2007, February 2010). All samples were tested using the Minilab® protocol, which includes disintegration and active ingredient assays as well as visual inspection, and most samples were also tested by Raman spectrometry. Results In Lagos, the failure rate in the 2010 sampling fell to 29% of the 2007 finding using the Minilab® protocol, 53% using Raman spectrometry, and 46% using visual inspection. In Accra, the failure rate in the 2010 sampling fell to 54% of the 2007 finding using the Minilab® protocol, 72% using Raman spectrometry, and 90% using visual inspection. Conclusions The evidence presented shows that drug quality is probably improving in both cities, especially Lagos, since major reductions of failure rates over time occur with all means of assessment. Many more samples failed when examined by Raman spectrometry than by Minilab® protocol. The discrepancy is most likely caused by the two techniques measuring different aspects of the medication and hence the discrepancy may be the natural variation in these techniques. But other explanations are possible and are discussed. PMID:20537190

  20. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    PubMed

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  1. Development of an Electromechanical Grade to Assess Human Knee Articular Cartilage Quality.

    PubMed

    Sim, Sotcheadt; Hadjab, Insaf; Garon, Martin; Quenneville, Eric; Lavigne, Patrick; Buschmann, Michael D

    2017-10-01

    Quantitative assessments of articular cartilage function are needed to aid clinical decision making. Our objectives were to develop a new electromechanical grade to assess quantitatively cartilage quality and test its reliability. Electromechanical properties were measured using a hand-held electromechanical probe on 200 human articular surfaces from cadaveric donors and osteoarthritic patients. These data were used to create a reference electromechanical property database and to compare with visual arthroscopic International Cartilage Repair Society (ICRS) grading of cartilage degradation. The effect of patient-specific and location-specific characteristics on electromechanical properties was investigated to construct a continuous and quantitative electromechanical grade analogous to ICRS grade. The reliability of this novel grade was assessed by comparing it with ICRS grades on 37 human articular surfaces. Electromechanical properties were not affected by patient-specific characteristics for each ICRS grade, but were significantly different across the articular surface. Electromechanical properties varied linearly with ICRS grade, leading to a simple linear transformation from one scale to the other. The electromechanical grade correlated strongly with ICRS grade (r = 0.92, p < 0.0001). Additionally, the electromechanical grade detected lesions that were not found visually. This novel grade can assist the surgeon in assessing human knee cartilage by providing a quantitative and reliable grading system.

  2. The effect of ice skating on psychological well-being and sleep quality of children with visual or hearing impairment.

    PubMed

    Dursun, Onur Burak; Erhan, Süleyman Erim; Ibiş, Esra Özhan; Esin, Ibrahim Selcuk; Keleş, Sadullah; Şirinkan, Ahmet; Yörük, Özgür; Acar, Ethem; Beyhun, Nazim Ercument

    2015-01-01

    Physical exercise and sports have a key role in preventing physical and psychiatric problems in children. However, children with a disability often experience difficulty participating in physical activity due to a lack of suitable opportunities. Participation in an accessible sport is particularly important for these children, but studies examining which sports are beneficial for which disability groups are rare. In this study, we assessed the effects of ice skating on the psychological well-being, self-concept, and sleep quality of children with hearing or visual impairment. Forty students (20 visually impaired and 20 hearing impaired) aged 8-16 were included in a regular ice skating programme for three months. We examined the sleep quality, self-concept, and behavioural and emotional states of the children before and after participating in the programme. There was a significant improvement in self-concept, behavioural and emotional problems, and sleep quality (p < 0.05 for each) of the children with hearing impairment. Although the sleep quality (p = 0.019) and emotional problem scores (p = 0.000) of the visually impaired children improved; self-concept, peer relations and hyperactivity scores of these children worsened (p < 0.05 for each). Ice skating is one of the popular sport alternatives that gives children the opportunity to exercise and have fun together. The results of this study revealed that regular ice skating programmes may have positive effects on the psychological well-being of children with hearing impairment. Despite some positive effects, caution must be use when including visually impaired children in ice skating programmes. Generalization of the study's outcomes is limited as the study group were residential students enrolled in special education institutions for children who are blind or deaf. Ice skating is a community-based sport and a popular leisure activity that can also have benefits for people with disabilities. Ice skating and children with hearing impairment: Self-concept, behavioural and emotional problems, and sleep quality of the children with hearing impairment significantly improved after ice skating. Ice skating programmes may be considered as a rehabilitation alternative for children with hearing impairment. Ice skating and children with visual impairment: Caution must be use when including children with visual impairment in ice skating programmes because of possible negative psychological outcomes. Balance exercises before starting the practices on ice should be considered for preventing some possible negative outcomes in children with visual impairment.

  3. A system to program projects to meet visual quality objectives

    Treesearch

    Fred L. Henley; Frank L. Hunsaker

    1979-01-01

    The U. S. Forest Service has established Visual Quality Objectives for National Forest lands and determined a method to ascertain the Visual Absorption Capability of those lands. Combining the two mapping inventories has allowed the Forest Service to retain the visual quality while managing natural resources.

  4. Comparison of Quality and Output of Different Optimal Perimetric Testing Approaches in Children With Glaucoma.

    PubMed

    Patel, Dipesh E; Cumberland, Phillippa M; Walters, Bronwen C; Russell-Eggitt, Isabelle; Brookes, John; Papadopoulos, Maria; Khaw, Peng Tee; Viswanathan, Ananth C; Garway-Heath, David; Cortina-Borja, Mario; Rahi, Jugnoo S

    2018-02-01

    There is limited evidence to support the development of guidance for visual field testing in children with glaucoma. To compare different static and combined static/kinetic perimetry approaches in children with glaucoma. Cross-sectional, observational study recruiting children prospectively between May 2013 and June 2015 at 2 tertiary specialist pediatric ophthalmology centers in London, England (Moorfields Eye Hospital and Great Ormond Street Hospital). The study included 65 children aged 5 to 15 years with glaucoma (108 affected eyes). A comparison of test quality and outcomes for static and combined static/kinetic techniques, with respect to ability to quantify glaucomatous loss. Children performed perimetric assessments using Humphrey static (Swedish Interactive Thresholding Algorithm 24-2 FAST) and Octopus combined static tendency-oriented perimetry/kinetic perimetry (isopter V4e, III4e, or I4e) in a single sitting, using standardized clinical protocols, administered by a single examiner. Information was collected about test duration, completion, and quality (using automated reliability indices and our qualitative Examiner-Based Assessment of Reliability score). Perimetry outputs were scored using the Aulhorn and Karmeyer classification. One affected eye in 19 participants was retested with Swedish Interactive Thresholding Algorithm 24-2 FAST and 24-2 standard algorithms. Sixty-five children (33 girls [50.8%]), with a median age of 12 years (interquartile range, 9-14 years), were tested. Test quality (Examiner-Based Assessment of Reliability score) improved with increasing age for both Humphrey and Octopus strategies and were equivalent in children older than 10 years (McNemar test, χ2 = 0.33; P = .56), but better-quality tests with Humphrey perimetry were achieved in younger children (McNemar test, χ2 = 4.0; P = .05). Octopus and Humphrey static MD values worse than or equal to -6 dB showed disagreement (Bland-Altman, mean difference, -0.70; limit of agreement, -7.74 to 6.35) but were comparable when greater than this threshold (mean difference, -0.03; limit of agreement, -2.33 to 2.27). Visual field classification scores for static perimetry tests showed substantial agreement (linearly weighted κ, 0.79; 95% CI, 0.65-0.93), although 25 of 80 (31%) were graded with a more severe defect for Octopus static perimetry. Of the 7 severe cases of visual field loss (grade 5), 5 had lower kinetic than static classification scores. A simple static perimetry approach potentially yields high-quality results in children younger than 10 years. For children older than 10 years, without penalizing quality, the addition of kinetic perimetry enabled measurement of far-peripheral sensitivity, which is particularly useful in children with severe visual field restriction.

  5. Contrasting the use of 2 vision-specific quality of life questionnaires in subjects with open-angle glaucoma.

    PubMed

    Wren, Patricia A; Musch, David C; Janz, Nancy K; Niziol, Leslie M; Guire, Kenneth E; Gillespie, Brenda W

    2009-01-01

    To compare 2 vision-specific functional status measures to each other and to clinical parameters in the Collaborative Initial Glaucoma Treatment Study (CIGTS). CIGTS participants completed the Visual Activities Questionnaire (VAQ) and the National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and were tested for visual field (VF) and visual acuity (VA). In all, 426 subjects contributed the VAQ and NEI-VFQ scores at 54 months. Pearson correlations were used to assess associations. The VAQ subscales (range, 0 to 100) that assessed light-dark adaptation (mean=66.1), glare disability (66.4), and acuity/spatial vision (67.7) indicated vision-related functions that CIGTS participants found most difficult. On the NEI-VFQ, subjects reported high levels of visual functioning, with mean >/=90 (out of 100) on the total score and in 9 of 12 subscales. General vision (mean=82.6) received the lowest subscale score. Two subscales common to both questionnaires were highly correlated: VA (r=0.68) and peripheral vision (r=0.77) (both P<0.0001). Correlations between participants' perceptions and clinical measures of visual function were in the expected direction, but weaker. Stronger associations were found between clinical measures and the NEI-VFQ than the VAQ. Better eye VF and worse eye VA had the highest number of significant correlations with subjects' perceptions of their visual function. Increasing VF loss was associated with a significant decrease in the overall and peripheral vision subscale scores from both questionnaires, and also several other subscales. CIGTS patients reported excellent visual function on both the NEI-VFQ and VAQ. These findings will help researchers interested in assessing patients' perceptions of their visual function make an informed selection when choosing between the VAQ and the NEI-VFQ.

  6. Clinical evaluation of watermarked medical images.

    PubMed

    Zain, Jasni M; Fauzi, Abdul M; Aziz, Azian A

    2006-01-01

    Digital watermarking medical images provides security to the images. The purpose of this study was to see whether digitally watermarked images changed clinical diagnoses when assessed by radiologists. We embedded 256 bits watermark to various medical images in the region of non-interest (RONI) and 480K bits in both region of interest (ROI) and RONI. Our results showed that watermarking medical images did not alter clinical diagnoses. In addition, there was no difference in image quality when visually assessed by the medical radiologists. We therefore concluded that digital watermarking medical images were safe in terms of preserving image quality for clinical purposes.

  7. The effect of two different visual presentation modalities on the narratives of mainstream grade 3 children.

    PubMed

    Klop, D; Engelbrecht, L

    2013-12-01

    This study investigated whether a dynamic visual presentation method (a soundless animated video presentation) would elicit better narratives than a static visual presentation method (a wordless picture book). Twenty mainstream grade 3 children were randomly assigned to two groups and assessed with one of the visual presentation methods. Narrative performance was measured in terms of micro- and macrostructure variables. Microstructure variables included productivity (total number of words, total number of T-units), syntactic complexity (mean length of T-unit) and lexical diversity measures (number of different words). Macrostructure variables included episodic structure in terms of goal-attempt-outcome (GAO) sequences. Both visual presentation modalities elicited narratives of similar quantity and quality in terms of the micro- and macrostructure variables that were investigated. Animation of picture stimuli did not elicit better narratives than static picture stimuli.

  8. Development of visibility forecasting modeling framework for the Lower Fraser Valley of British Columbia using Canada's Regional Air Quality Deterministic Prediction System.

    PubMed

    So, Rita; Teakles, Andrew; Baik, Jonathan; Vingarzan, Roxanne; Jones, Keith

    2018-05-01

    Visibility degradation, one of the most noticeable indicators of poor air quality, can occur despite relatively low levels of particulate matter when the risk to human health is low. The availability of timely and reliable visibility forecasts can provide a more comprehensive understanding of the anticipated air quality conditions to better inform local jurisdictions and the public. This paper describes the development of a visibility forecasting modeling framework, which leverages the existing air quality and meteorological forecasts from Canada's operational Regional Air Quality Deterministic Prediction System (RAQDPS) for the Lower Fraser Valley of British Columbia. A baseline model (GM-IMPROVE) was constructed using the revised IMPROVE algorithm based on unprocessed forecasts from the RAQDPS. Three additional prototypes (UMOS-HYB, GM-MLR, GM-RF) were also developed and assessed for forecast performance of up to 48 hr lead time during various air quality and meteorological conditions. Forecast performance was assessed by examining their ability to provide both numerical and categorical forecasts in the form of 1-hr total extinction and Visual Air Quality Ratings (VAQR), respectively. While GM-IMPROVE generally overestimated extinction more than twofold, it had skill in forecasting the relative species contribution to visibility impairment, including ammonium sulfate and ammonium nitrate. Both statistical prototypes, GM-MLR and GM-RF, performed well in forecasting 1-hr extinction during daylight hours, with correlation coefficients (R) ranging from 0.59 to 0.77. UMOS-HYB, a prototype based on postprocessed air quality forecasts without additional statistical modeling, provided reasonable forecasts during most daylight hours. In terms of categorical forecasts, the best prototype was approximately 75 to 87% correct, when forecasting for a condensed three-category VAQR. A case study, focusing on a poor visual air quality yet low Air Quality Health Index episode, illustrated that the statistical prototypes were able to provide timely and skillful visibility forecasts with lead time up to 48 hr. This study describes the development of a visibility forecasting modeling framework, which leverages the existing air quality and meteorological forecasts from Canada's operational Regional Air Quality Deterministic Prediction System. The main applications include tourism and recreation planning, input into air quality management programs, and educational outreach. Visibility forecasts, when supplemented with the existing air quality and health based forecasts, can assist jurisdictions to anticipate the visual air quality impacts as perceived by the public, which can potentially assist in formulating the appropriate air quality bulletins and recommendations.

  9. Automated Quality Assessment of Structural Magnetic Resonance Brain Images Based on a Supervised Machine Learning Algorithm.

    PubMed

    Pizarro, Ricardo A; Cheng, Xi; Barnett, Alan; Lemaitre, Herve; Verchinski, Beth A; Goldman, Aaron L; Xiao, Ena; Luo, Qian; Berman, Karen F; Callicott, Joseph H; Weinberger, Daniel R; Mattay, Venkata S

    2016-01-01

    High-resolution three-dimensional magnetic resonance imaging (3D-MRI) is being increasingly used to delineate morphological changes underlying neuropsychiatric disorders. Unfortunately, artifacts frequently compromise the utility of 3D-MRI yielding irreproducible results, from both type I and type II errors. It is therefore critical to screen 3D-MRIs for artifacts before use. Currently, quality assessment involves slice-wise visual inspection of 3D-MRI volumes, a procedure that is both subjective and time consuming. Automating the quality rating of 3D-MRI could improve the efficiency and reproducibility of the procedure. The present study is one of the first efforts to apply a support vector machine (SVM) algorithm in the quality assessment of structural brain images, using global and region of interest (ROI) automated image quality features developed in-house. SVM is a supervised machine-learning algorithm that can predict the category of test datasets based on the knowledge acquired from a learning dataset. The performance (accuracy) of the automated SVM approach was assessed, by comparing the SVM-predicted quality labels to investigator-determined quality labels. The accuracy for classifying 1457 3D-MRI volumes from our database using the SVM approach is around 80%. These results are promising and illustrate the possibility of using SVM as an automated quality assessment tool for 3D-MRI.

  10. Efficacy of a task-based training approach in the rehabilitation of three children with poor handwriting quality: a pilot study.

    PubMed

    Baldi, Silvia; Nunzi, Michela; Brina, Carlo Di

    2015-02-01

    Evidence suggests that task-based training approaches can improve the performance of children with handwriting difficulties. The present case study tests the efficacy of the Handwriting Task Program (HTP). Three male children (9-10 yr. old) with poor handwriting skills and different developmental disorders participated in the HTP, twice per week, for 13 wk. Handwriting legibility was assessed through the Concise Evaluation Scale for Children's Handwriting, and fine motor performance and handwriting speed were evaluated at pre- and post-treatment with the Visual Motor Integration Test and the Battery for the assessment of writing skills of children from 7 to 13 yr. old. The results showed that motor efficiency and global handwriting quality improved in all the children, although some handwriting difficulties still persisted in one child with Developmental Coordination Disorder (DCD). Further study may confirm on a larger sample that a visual-spatially based training may improve the handwriting legibility of children with DCD.

  11. Computer use, symptoms, and quality of life.

    PubMed

    Hayes, John R; Sheedy, James E; Stelmack, Joan A; Heaney, Catherine A

    2007-08-01

    To model the effects of computer use on reported visual and physical symptoms and to measure the effects upon quality of life measures. A survey of 1000 university employees (70.5% adjusted response rate) assessed visual and physical symptoms, job, physical and mental demands, ability to control/influence work, amount of work at a computer, computer work environment, relations with others at work, life and job satisfaction, and quality of life. Data were analyzed to determine whether self-reported eye symptoms are associated with perceived quality of life. The study also explored the factors that are associated with eye symptoms. Structural equation modeling and multiple regression analyses were used to assess the hypotheses. Seventy percent of the employees used some form of vision correction during computer use, 2.9% used glasses specifically prescribed for computer use, and 8% had had refractive surgery. Employees spent an average of 6 h per day at the computer. In a multiple regression framework, the latent variable eye symptoms was significantly associated with a composite quality of life variable (p = 0.02) after adjusting for job quality, job satisfaction, supervisor relations, co-worker relations, mental and physical load of the job, and job demand. Age and gender were not significantly associated with symptoms. After adjusting for age, gender, ergonomics, hours at the computer, and exercise, eye symptoms were significantly associated with physical symptoms (p < 0.001) accounting for 48% of the variance. Environmental variability at work was associated with eye symptoms and eye symptoms demonstrated a significant impact on quality of life and physical symptoms.

  12. [Quality of life in patients with age-related macular degeneration - medical and social problem].

    PubMed

    Muzyka-Woźniak, Maria; Misiuk-Hojło, Marta; Wesolowska, Alicja

    2011-01-01

    Age-related macular degeneration (AMD) is a leading cause of blindness over the age of 50 in western countries. People with AMD are suffering from serious vision-related disability and their social life is compromised. The aim of our study was to assess quality of life (QoL) in patients with exudative AMD. The study group was 100 patients treated for AMD, the control group were 30 age and sex matched subjects without ophthalmic disorders. Patients were treated with anti-VEGF therapy, by means of National Eye Institute Visual Function Questionnaire (NEI VFQ-25). As well as visual function, the NEI-VFQ investigates social functioning, mental health and dependency. There was statistically significant difference in QoL overall score between study group and control group. Patients with AMD obtained 51.1 (+/- 20.5 ) overall score, control group reached 83.7 (+/- 11.7) overall score, p = 0.001. Detailed analysis of study group revealed low acceptance of the disease and strong dependency. QoL in patients with AMD assessed with NEI VFQ-25, is significantly impaired. Low quality of life and difficulties in performing daily activities point at the need of formal psychological and social care.

  13. Application of machine learning for the evaluation of turfgrass plots using aerial images

    NASA Astrophysics Data System (ADS)

    Ding, Ke; Raheja, Amar; Bhandari, Subodh; Green, Robert L.

    2016-05-01

    Historically, investigation of turfgrass characteristics have been limited to visual ratings. Although relevant information may result from such evaluations, final inferences may be questionable because of the subjective nature in which the data is collected. Recent advances in computer vision techniques allow researchers to objectively measure turfgrass characteristics such as percent ground cover, turf color, and turf quality from the digital images. This paper focuses on developing a methodology for automated assessment of turfgrass quality from aerial images. Images of several turfgrass plots of varying quality were gathered using a camera mounted on an unmanned aerial vehicle. The quality of these plots were also evaluated based on visual ratings. The goal was to use the aerial images to generate quality evaluations on a regular basis for the optimization of water treatment. Aerial images are used to train a neural network so that appropriate features such as intensity, color, and texture of the turfgrass are extracted from these images. Neural network is a nonlinear classifier commonly used in machine learning. The output of the neural network trained model is the ratings of the grass, which is compared to the visual ratings. Currently, the quality and the color of turfgrass, measured as the greenness of the grass, are evaluated. The textures are calculated using the Gabor filter and co-occurrence matrix. Other classifiers such as support vector machines and simpler linear regression models such as Ridge regression and LARS regression are also used. The performance of each model is compared. The results show encouraging potential for using machine learning techniques for the evaluation of turfgrass quality and color.

  14. Aesthetics by Numbers: Links between Perceived Texture Qualities and Computed Visual Texture Properties.

    PubMed

    Jacobs, Richard H A H; Haak, Koen V; Thumfart, Stefan; Renken, Remco; Henson, Brian; Cornelissen, Frans W

    2016-01-01

    Our world is filled with texture. For the human visual system, this is an important source of information for assessing environmental and material properties. Indeed-and presumably for this reason-the human visual system has regions dedicated to processing textures. Despite their abundance and apparent relevance, only recently the relationships between texture features and high-level judgments have captured the interest of mainstream science, despite long-standing indications for such relationships. In this study, we explore such relationships, as these might be used to predict perceived texture qualities. This is relevant, not only from a psychological/neuroscience perspective, but also for more applied fields such as design, architecture, and the visual arts. In two separate experiments, observers judged various qualities of visual textures such as beauty, roughness, naturalness, elegance, and complexity. Based on factor analysis, we find that in both experiments, ~75% of the variability in the judgments could be explained by a two-dimensional space, with axes that are closely aligned to the beauty and roughness judgments. That a two-dimensional judgment space suffices to capture most of the variability in the perceived texture qualities suggests that observers use a relatively limited set of internal scales on which to base various judgments, including aesthetic ones. Finally, for both of these judgments, we determined the relationship with a large number of texture features computed for each of the texture stimuli. We find that the presence of lower spatial frequencies, oblique orientations, higher intensity variation, higher saturation, and redness correlates with higher beauty ratings. Features that captured image intensity and uniformity correlated with roughness ratings. Therefore, a number of computational texture features are predictive of these judgments. This suggests that perceived texture qualities-including the aesthetic appreciation-are sufficiently universal to be predicted-with reasonable accuracy-based on the computed feature content of the textures.

  15. The compressed average image intensity metric for stereoscopic video quality assessment

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2016-09-01

    The following article depicts insights towards design, creation and testing of a genuine metric designed for a 3DTV video quality evaluation. The Compressed Average Image Intensity (CAII) mechanism is based upon stereoscopic video content analysis, setting its core feature and functionality to serve as a versatile tool for an effective 3DTV service quality assessment. Being an objective type of quality metric it may be utilized as a reliable source of information about the actual performance of a given 3DTV system, under strict providers evaluation. Concerning testing and the overall performance analysis of the CAII metric, the following paper presents comprehensive study of results gathered across several testing routines among selected set of samples of stereoscopic video content. As a result, the designed method for stereoscopic video quality evaluation is investigated across the range of synthetic visual impairments injected into the original video stream.

  16. Research on assessment and improvement method of remote sensing image reconstruction

    NASA Astrophysics Data System (ADS)

    Sun, Li; Hua, Nian; Yu, Yanbo; Zhao, Zhanping

    2018-01-01

    Remote sensing image quality assessment and improvement is an important part of image processing. Generally, the use of compressive sampling theory in remote sensing imaging system can compress images while sampling which can improve efficiency. A method of two-dimensional principal component analysis (2DPCA) is proposed to reconstruct the remote sensing image to improve the quality of the compressed image in this paper, which contain the useful information of image and can restrain the noise. Then, remote sensing image quality influence factors are analyzed, and the evaluation parameters for quantitative evaluation are introduced. On this basis, the quality of the reconstructed images is evaluated and the different factors influence on the reconstruction is analyzed, providing meaningful referential data for enhancing the quality of remote sensing images. The experiment results show that evaluation results fit human visual feature, and the method proposed have good application value in the field of remote sensing image processing.

  17. Visual Assessment of Brain Perfusion MRI Scans in Dementia: A Pilot Study.

    PubMed

    Fällmar, David; Lilja, Johan; Velickaite, Vilma; Danfors, Torsten; Lubberink, Mark; Ahlgren, André; van Osch, Matthias J P; Kilander, Lena; Larsson, Elna-Marie

    2016-05-01

    Functional imaging is becoming increasingly important for the detection of neurodegenerative disorders. Perfusion MRI with arterial spin labeling (ASL) has been reported to provide promising diagnostic possibilities but is not yet widely used in routine clinical work. The aim of this study was to compare, in a clinical setting, the visual assessment of subtracted ASL CBF maps with and without additional smoothing, to FDG-PET data. Ten patients with a clinical diagnosis of dementia and 11 age-matched cognitively healthy controls were examined with pseudo-continuous ASL (pCASL) and 18F-Fluorodeoxyglucose positron emission tomography (FDG-PET). Three diagnostic physicians visually assessed the pCASL maps after subtraction only, and after postprocessing using Gaussian smoothing and GLM-based beta estimate functions. The assessment scores were compared to FDG PET values. Furthermore, the ability to discriminate patients from healthy elderly controls was assessed. Smoothing improved the correlation between visually assessed regional ASL perfusion scores and the FDG PET SUV-r values from the corresponding regions. However, subtracted pCASL maps discriminated patients from healthy controls better than smoothed maps. Smoothing increased the number of false-positive patient identifications. Application of beta estimate functions had only a marginal effect. Spatial smoothing of ASL images increased false positive results in the discrimination of hypoperfusion conditions from healthy elderly. It also decreased interreader agreement. However, regional characterization and subjective perception of image quality was improved. Copyright © 2015 by the American Society of Neuroimaging.

  18. A prospective profile of visual field loss following stroke: prevalence, type, rehabilitation, and outcome.

    PubMed

    Rowe, Fiona J; Wright, David; Brand, Darren; Jackson, Carole; Harrison, Shirley; Maan, Tallat; Scott, Claire; Vogwell, Linda; Peel, Sarah; Akerman, Nicola; Dodridge, Caroline; Howard, Claire; Shipman, Tracey; Sperring, Una; Macdiarmid, Sonia; Freeman, Cicely

    2013-01-01

    To profile site of stroke/cerebrovascular accident, type and extent of field loss, treatment options, and outcome. Prospective multicentre cohort trial. Standardised referral and investigation protocol of visual parameters. 915 patients were recruited with a mean age of 69 years (SD 14). 479 patients (52%) had visual field loss. 51 patients (10%) had no visual symptoms. Almost half of symptomatic patients (n = 226) complained only of visual field loss: almost half (n = 226) also had reading difficulty, blurred vision, diplopia, and perceptual difficulties. 31% (n = 151) had visual field loss as their only visual impairment: 69% (n = 328) had low vision, eye movement deficits, or visual perceptual difficulties. Occipital and parietal lobe strokes most commonly caused visual field loss. Treatment options included visual search training, visual awareness, typoscopes, substitutive prisms, low vision aids, refraction, and occlusive patches. At followup 15 patients (7.5%) had full recovery, 78 (39%) had improvement, and 104 (52%) had no recovery. Two patients (1%) had further decline of visual field. Patients with visual field loss had lower quality of life scores than stroke patients without visual impairment. Stroke survivors with visual field loss require assessment to accurately define type and extent of loss, diagnose coexistent visual impairments, and offer targeted treatment.

  19. LASIK for myopia and astigmatism using the SCHWIND AMARIS excimer laser: an international multicenter trial.

    PubMed

    Arbelaez, Maria Clara; Aslanides, Ioannis M; Barraquer, Carmen; Carones, Francesco; Feuermannova, Alena; Neuhann, Tobias; Rozsival, Pavel

    2010-02-01

    To assess the efficacy, predictability, and safety of LASIK for the surgical correction of low to moderate myopia with astigmatism using the SCHWIND AMARIS excimer laser. Six international study sites enrolled 358 eyes with a manifest refraction spherical equivalent (MRSE) from -0.50 to -7.38 diopters (D) (mean sphere: -3.13+/-1.58 D) with up to -5.00 D of astigmatism (mean: -0.69+/-0.67 D). All eyes underwent treatment with the nonwavefront-guided aspheric algorithm of the SCHWIND AMARIS excimer laser. All eyes were targeted for emmetropia. Refractive outcomes and corneal higher order aberrations were analyzed pre- and postoperatively. Visual quality was assessed using photopic and mesopic contrast sensitivity. Six-month postoperative outcomes are reported. At 6 months postoperative, the MRSE for all eyes was -0.21+/-0.20 D, and 96% (343/358) of eyes had MRSE within +/-0.50 D. Uncorrected visual acuity was 20/20 or better in 98% (351/358) of eyes, and no eyes lost 2 or more lines of best spectacle-corrected visual acuity. The total corneal higher order aberrations root-mean-square increased by 0.09 microm, spherical aberration increased by 0.08 microm, and coma increased by 0.04 microm postoperatively. Photopic and mesopic contrast sensitivity did not change 6 months postoperatively. Treatment of myopia with astigmatism using the SCHWIND AMARIS excimer laser is safe, efficacious, predictable, and maintains visual quality.

  20. ASSESSING THE COMPARABILITY OF AMMONIUM, NITRATE AND SULFATE CONCENTRATIONS MEASURED BY THREE AIR QUALITY MONITORING NETWORKS

    EPA Science Inventory

    Airborne fine particulate matter across the United States is monitored by different networks, the three prevalent ones presently being the Clean Air Status and Trend Network (CASTNet), the Interagency Monitoring of PROtected Visual Environment Network (IMPROVE) and the Speciati...

  1. Refractive index and its impact on pseudophakic dysphotopsia.

    PubMed

    Radmall, Bryce R; Floyd, Anne; Oakey, Zack; Olson, Randall J

    2015-01-01

    It has been shown that the biggest dissatisfier for uncomplicated cataract surgery patients is pseudophakic dysphotopsia (PD). While edge design of an intraocular lens (IOL) impacts this problem, refractive index is still controversial as to its impact. This retrospective cohort study was designed to determine the role of increasing refractive index in PD. This study was conducted at the John A. Moran Eye Center, University of Utah, USA. A retrospective chart review identified patients who received one of two hydrophobic acrylic single piece IOLs (AcrySof WF SP [SN60WF] or Tecnis SP [ZCB00]), which differed mainly by refractive index (1.55 versus 1.47). Eighty-seven patients who had received implantation of a one-piece hydrophobic acrylic IOL were enrolled. Patients were included if the surgery had been uncomplicated and took place at least a year before study participation. All eligible patients had 20/20 best corrected vision, without any disease known to impact visual quality. In addition to conducting a record review, the enrolled patients were surveyed for PD, using a modified National Eye Institute Visual Function questionnaire, as well as for overall satisfaction with visual quality. Statistical analysis demonstrated no difference between the two cohorts regarding PD, general visual function, and overall visual satisfaction. The study suggests that with the two IOLs assessed, increasing the refractive index does not increase incidence of PD or decrease overall visual satisfaction.

  2. Assessing the Effect of Early Visual Cortex Transcranial Magnetic Stimulation on Working Memory Consolidation.

    PubMed

    van Lamsweerde, Amanda E; Johnson, Jeffrey S

    2017-07-01

    Maintaining visual working memory (VWM) representations recruits a network of brain regions, including the frontal, posterior parietal, and occipital cortices; however, it is unclear to what extent the occipital cortex is engaged in VWM after sensory encoding is completed. Noninvasive brain stimulation data show that stimulation of this region can affect working memory (WM) during the early consolidation time period, but it remains unclear whether it does so by influencing the number of items that are stored or their precision. In this study, we investigated whether single-pulse transcranial magnetic stimulation (spTMS) to the occipital cortex during VWM consolidation affects the quantity or quality of VWM representations. In three experiments, we disrupted VWM consolidation with either a visual mask or spTMS to retinotopic early visual cortex. We found robust masking effects on the quantity of VWM representations up to 200 msec poststimulus offset and smaller, more variable effects on WM quality. Similarly, spTMS decreased the quantity of VWM representations, but only when it was applied immediately following stimulus offset. Like visual masks, spTMS also produced small and variable effects on WM precision. The disruptive effects of both masks and TMS were greatly reduced or entirely absent within 200 msec of stimulus offset. However, there was a reduction in swap rate across all time intervals, which may indicate a sustained role of the early visual cortex in maintaining spatial information.

  3. A comparative study of multi-focus image fusion validation metrics

    NASA Astrophysics Data System (ADS)

    Giansiracusa, Michael; Lutz, Adam; Messer, Neal; Ezekiel, Soundararajan; Alford, Mark; Blasch, Erik; Bubalo, Adnan; Manno, Michael

    2016-05-01

    Fusion of visual information from multiple sources is relevant for applications security, transportation, and safety applications. One way that image fusion can be particularly useful is when fusing imagery data from multiple levels of focus. Different focus levels can create different visual qualities for different regions in the imagery, which can provide much more visual information to analysts when fused. Multi-focus image fusion would benefit a user through automation, which requires the evaluation of the fused images to determine whether they have properly fused the focused regions of each image. Many no-reference metrics, such as information theory based, image feature based and structural similarity-based have been developed to accomplish comparisons. However, it is hard to scale an accurate assessment of visual quality which requires the validation of these metrics for different types of applications. In order to do this, human perception based validation methods have been developed, particularly dealing with the use of receiver operating characteristics (ROC) curves and the area under them (AUC). Our study uses these to analyze the effectiveness of no-reference image fusion metrics applied to multi-resolution fusion methods in order to determine which should be used when dealing with multi-focus data. Preliminary results show that the Tsallis, SF, and spatial frequency metrics are consistent with the image quality and peak signal to noise ratio (PSNR).

  4. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    NASA Astrophysics Data System (ADS)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric shade colors. The results clearly show the benefit of automatic shade control strategies with integrated lighting control over a condition when shades are closed all day. The main contributor to the total energy savings is from lighting energy savings, followed by cooling energy savings. Shades provide greater benefit in a hot climate and in a moderate climate than in a cold climate. Different control strategies provide savings in the range of 7-35% for annual total space energy with higher savings with light colored shades. Control strategies of shades should be selected and optimized based on climate, orientation, window area, and window/shade properties. High performance glazings, when equipped with shades, show lower energy savings when compared to standard glazings. High transmittance/reflectance shades, such as white shades, perform better than dark shades in most of the cases due to higher lighting energy savings obtained with the automatic electric lighting control and the resulting cooling energy savings from rejection of some solar energy and a reduction in the heat from lights. A South orientation showed the least benefit of automatic control of shades when compare to other orientations due to the large fraction of time shades are required to provide visual comfort. Under automatic shade control, energy savings are higher the more often the shades can be raised. The different automatic control strategies present tradeoffs between energy savings and comfort. With regard to visual quality, daylight quality assessments on view, glare, luminance ratios, and UDI can be used to assess shade control strategies. Automatic shade control can increase the number of view hours while controlling sunlight penetration. With automatic shade control, more daylight hours can be provided within the beneficial range of 100-2000 lux compared to shades that are closed all day. For a person facing the window, discomfort glare is likely to increase the more often the shades are raised. Keeping the shades down ensures an acceptable glare condition, but limits energy savings. Luminance ratios are another metric that can be used to assess shade performance. With white shades, the luminance ratios between the task and proximate surfaces are improved. Dark shades help improve the luminance ratios between the task and distant surfaces. When the shades are left open, even with no direct sunlight in the space, task to window luminance ratios will often exceed 1:10.

  5. Visual Functioning and Health-related Quality-of-Life are Compromised in Patients with Uveitis.

    PubMed

    Hui, Michelle M; Wakefield, Denis; Patel, Ilesh; Cvejic, Erin; McCluskey, Peter J; Chang, John H

    2017-08-01

    To assess the vision-related (VR) and health-related (HR) quality-of-life (QoL) of patients with uveitis. In total, 60 patients with uveitis, 81 patients with diabetic retinopathy (DR), and 70 healthy subjects completed the National Eye Institute Visual Functioning Questionnaire and the Medical Outcome Study 36-Item Short Form. Patients with uveitis reported lower HR- and VR-QoL than healthy subjects (p<0.05) and lower VR-QoL (p<0.001) than patients with DR. For patients with uveitis, multiple linear regression analyses indicated that lower HR-QoL scores were predicted by younger age (p<0.01), while lower VR-QoL scores were predicted by poorer visual acuity (p<0.001), ocular comorbidities (p<0.05), and female sex (p<0.05). Patients with uveitis have significantly poorer VR- and HR-QoL than healthy control subjects. Uveitis has a more debilitating impact on VR-QoL than DR.

  6. Lenticuloschisis: A "No Dissection" Technique for Lenticule Extraction in Small Incision Lenticule Extraction.

    PubMed

    Ganesh, Sri; Brar, Sheetal

    2017-08-01

    To describe a "no dissection" technique of lenticule removal in small incision lenticule extraction (SMILE). After docking and laser delivery, a microforceps is used to grasp and gently peel off the lenticule from the underlying stromal bed, without performing any dissection of the upper and lower planes of the lenticule. Prerequisites are a surgeon experienced in the conventional SMILE technique, optimized laser energy settings, and a minimum peripheral lenticule thickness of 25 to 30 µm. The interface as assessed in postoperative dilated clinical photographs was seen to be clearer with less roughness compared to the conventional dissection technique. This may potentially result in better first postoperative visual acuity and quality of vision due to less corneal tissue trauma and minimal tissue handling, thus potentially resulting in faster visual recovery. No dissection lenticule removal is a feasible and reproducible technique that may result in better immediate visual quality compared to the conventional SMILE technique. [J Refract Surg. 2017;33(8):563-566.]. Copyright 2017, SLACK Incorporated.

  7. Visual Sample Plan Version 7.0 User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzke, Brett D.; Newburn, Lisa LN; Hathaway, John E.

    2014-03-01

    User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination.more » The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.« less

  8. The Quality of Medicines Used in Children and Supplied by Private Pharmaceutical Wholesalers in Kinshasa, Democratic Republic of Congo: A Prospective Survey.

    PubMed

    Schiavetti, Benedetta; Wynendaele, Evelien; De Spiegeleer, Bart; Mbinze, Geremie J; Kalenda, Nicodème; Marini, Roland; Melotte, Vera; Hasker, Epco; Meessen, Bruno; Ravinetto, Raffaella; Van der Elst, Josiane; Mutolo Ngeleka, Daniel

    2018-03-01

    Poor-quality medicines are a threat to public health in many low- and middle-income countries, and prospective surveys are needed to inform corrective actions. Therefore, we conducted a cross-sectional survey on a sample of products used for children and available in the private market in Kinshasa, Democratic Republic Congo: amoxicillin (AX) and artemether/lumefantrine (AL), powders for suspension, and paracetamol (PC) tablets 500 mg. Overall, 417 products were covertly purchased from 61 wholesalers. To obtain a representative sample, the products were weighted on their market shares and a subset of 239 samples was randomly extracted to undergo in-depth visual inspection locally, and they were chemically assessed at two accredited laboratories in Belgium. Samples were defined of "poor-quality" if they failed to comply with at least one specification of the International Pharmacopoeia (for AL) or United States Pharmacopoeia 37 (for AX and PC). Results are reported according to the Medicine Quality Assessment Reporting Guideline. The visual inspection detected nonconformities in the aspects of antimalarial powders for suspension, and poor-quality labels across all medicine types. According to chemical analysis, 27.2% samples were of poor quality and 59.5% of AL samples were underdosed in artemether. Poor quality was more frequent for locally manufactured antimalarials (83.3%, P = 0.021; 86.4%, P = 0.022) and PC (4.8%, P = 0.000). The poor quality of the surveyed products may decrease the treatment's efficacy and favor the development of resistances to antimalarials. It is hoped that these findings may guide the corrective actions of the Democratic Republic of Congo Regulatory Authority, which was the main partner in the research.

  9. Learning a No-Reference Quality Assessment Model of Enhanced Images With Big Data.

    PubMed

    Gu, Ke; Tao, Dacheng; Qiao, Jun-Fei; Lin, Weisi

    2018-04-01

    In this paper, we investigate into the problem of image quality assessment (IQA) and enhancement via machine learning. This issue has long attracted a wide range of attention in computational intelligence and image processing communities, since, for many practical applications, e.g., object detection and recognition, raw images are usually needed to be appropriately enhanced to raise the visual quality (e.g., visibility and contrast). In fact, proper enhancement can noticeably improve the quality of input images, even better than originally captured images, which are generally thought to be of the best quality. In this paper, we present two most important contributions. The first contribution is to develop a new no-reference (NR) IQA model. Given an image, our quality measure first extracts 17 features through analysis of contrast, sharpness, brightness and more, and then yields a measure of visual quality using a regression module, which is learned with big-data training samples that are much bigger than the size of relevant image data sets. The results of experiments on nine data sets validate the superiority and efficiency of our blind metric compared with typical state-of-the-art full-reference, reduced-reference and NA IQA methods. The second contribution is that a robust image enhancement framework is established based on quality optimization. For an input image, by the guidance of the proposed NR-IQA measure, we conduct histogram modification to successively rectify image brightness and contrast to a proper level. Thorough tests demonstrate that our framework can well enhance natural images, low-contrast images, low-light images, and dehazed images. The source code will be released at https://sites.google.com/site/guke198701/publications.

  10. Non-Destructive Spectroscopic Techniques and Multivariate Analysis for Assessment of Fat Quality in Pork and Pork Products: A Review

    PubMed Central

    Kucha, Christopher T.; Liu, Li; Ngadi, Michael O.

    2018-01-01

    Fat is one of the most important traits determining the quality of pork. The composition of the fat greatly influences the quality of pork and its processed products, and contribute to defining the overall carcass value. However, establishing an efficient method for assessing fat quality parameters such as fatty acid composition, solid fat content, oxidative stability, iodine value, and fat color, remains a challenge that must be addressed. Conventional methods such as visual inspection, mechanical methods, and chemical methods are used off the production line, which often results in an inaccurate representation of the process because the dynamics are lost due to the time required to perform the analysis. Consequently, rapid, and non-destructive alternative methods are needed. In this paper, the traditional fat quality assessment techniques are discussed with emphasis on spectroscopic techniques as an alternative. Potential spectroscopic techniques include infrared spectroscopy, nuclear magnetic resonance and Raman spectroscopy. Hyperspectral imaging as an emerging advanced spectroscopy-based technology is introduced and discussed for the recent development of assessment for fat quality attributes. All techniques are described in terms of their operating principles and the research advances involving their application for pork fat quality parameters. Future trends for the non-destructive spectroscopic techniques are also discussed. PMID:29382092

  11. [Relationship between image quality and cross-sectional area of phantom in three-dimensional positron emission tomography scan].

    PubMed

    Osawa, Atsushi; Miwa, Kenta; Wagatsuma, Kei; Takiguchi, Tomohiro; Tamura, Shintaro; Akimoto, Kenta

    2012-01-01

    The image quality in (18)FDG PET/CT often degrades as the body size increases. The purpose of this study was to evaluate the relationship between image quality and the body size using original phantoms of variable cross-sectional areas in PET/CT. We produced five water phantoms with different cross-sectional areas. The long axis of phantom was 925 mm, and the cross-sectional area was from 324 to 1189 cm(2). These phantoms with the sphere (diameter 10 mm) were filled with (18)F-FDG solution. The radioactivity concentration of background in the phantom was 1.37, 2.73, 4.09 and 5.46 kBq/mL. The scanning duration was 30 min in list mode acquisition for each measurement. Background variability (N(10 mm)), noise equivalent count rates (NECR(phantom)), hot sphere contrast (Q(H,10 mm)) as physical evaluation and visual score of sphere detection were measured, respectively. The relationship between image quality and the various cross-sectional areas was also analyzed under the above-mentioned conditions. As cross-sectional area increased, NECR(phantom) progressively decreased. Furthermore, as cross-sectional area increased, N(10 mm) increased and Q(H,10 mm) decreased. Image quality became degraded as body weight increased because noise and contrast contributed to image quality. The visual score of sphere detection deteriorated in high background radioactivity concentration because a false positive detection in cross-sectional area of the phantom increased. However, additional increases in scanning periods could improve the visual score. We assessed tendencies in the relationship between image quality and body size in PET/CT. Our results showed that time adjustment was more effective than dose adjustment for stable image quality of heavier patients in terms of the large cross-sectional area.

  12. Audio-visual presentation of information for informed consent for participation in clinical trials.

    PubMed

    Synnot, Anneliese; Ryan, Rebecca; Prictor, Megan; Fetherstonhaugh, Deirdre; Parker, Barbara

    2014-05-09

    Informed consent is a critical component of clinical research. Different methods of presenting information to potential participants of clinical trials may improve the informed consent process. Audio-visual interventions (presented, for example, on the Internet or on DVD) are one such method. We updated a 2008 review of the effects of these interventions for informed consent for trial participation. To assess the effects of audio-visual information interventions regarding informed consent compared with standard information or placebo audio-visual interventions regarding informed consent for potential clinical trial participants, in terms of their understanding, satisfaction, willingness to participate, and anxiety or other psychological distress. We searched: the Cochrane Central Register of Controlled Trials (CENTRAL), The Cochrane Library, issue 6, 2012; MEDLINE (OvidSP) (1946 to 13 June 2012); EMBASE (OvidSP) (1947 to 12 June 2012); PsycINFO (OvidSP) (1806 to June week 1 2012); CINAHL (EbscoHOST) (1981 to 27 June 2012); Current Contents (OvidSP) (1993 Week 27 to 2012 Week 26); and ERIC (Proquest) (searched 27 June 2012). We also searched reference lists of included studies and relevant review articles, and contacted study authors and experts. There were no language restrictions. We included randomised and quasi-randomised controlled trials comparing audio-visual information alone, or in conjunction with standard forms of information provision (such as written or verbal information), with standard forms of information provision or placebo audio-visual information, in the informed consent process for clinical trials. Trials involved individuals or their guardians asked to consider participating in a real or hypothetical clinical study. (In the earlier version of this review we only included studies evaluating informed consent interventions for real studies). Two authors independently assessed studies for inclusion and extracted data. We synthesised the findings using meta-analysis, where possible, and narrative synthesis of results. We assessed the risk of bias of individual studies and considered the impact of the quality of the overall evidence on the strength of the results. We included 16 studies involving data from 1884 participants. Nine studies included participants considering real clinical trials, and eight included participants considering hypothetical clinical trials, with one including both. All studies were conducted in high-income countries.There is still much uncertainty about the effect of audio-visual informed consent interventions on a range of patient outcomes. However, when considered across comparisons, we found low to very low quality evidence that such interventions may slightly improve knowledge or understanding of the parent trial, but may make little or no difference to rate of participation or willingness to participate. Audio-visual presentation of informed consent may improve participant satisfaction with the consent information provided. However its effect on satisfaction with other aspects of the process is not clear. There is insufficient evidence to draw conclusions about anxiety arising from audio-visual informed consent. We found conflicting, very low quality evidence about whether audio-visual interventions took more or less time to administer. No study measured researcher satisfaction with the informed consent process, nor ease of use.The evidence from real clinical trials was rated as low quality for most outcomes, and for hypothetical studies, very low. We note, however, that this was in large part due to poor study reporting, the hypothetical nature of some studies and low participant numbers, rather than inconsistent results between studies or confirmed poor trial quality. We do not believe that any studies were funded by organisations with a vested interest in the results. The value of audio-visual interventions as a tool for helping to enhance the informed consent process for people considering participating in clinical trials remains largely unclear, although trends are emerging with regard to improvements in knowledge and satisfaction. Many relevant outcomes have not been evaluated in randomised trials. Triallists should continue to explore innovative methods of providing information to potential trial participants during the informed consent process, mindful of the range of outcomes that the intervention should be designed to achieve, and balancing the resource implications of intervention development and delivery against the purported benefits of any intervention.More trials, adhering to CONSORT standards, and conducted in settings and populations underserved in this review, i.e. low- and middle-income countries and people with low literacy, would strengthen the results of this review and broaden its applicability. Assessing process measures, such as time taken to administer the intervention and researcher satisfaction, would inform the implementation of audio-visual consent materials.

  13. Vision and vision-related outcome measures in multiple sclerosis

    PubMed Central

    Balcer, Laura J.; Miller, David H.; Reingold, Stephen C.

    2015-01-01

    Visual impairment is a key manifestation of multiple sclerosis. Acute optic neuritis is a common, often presenting manifestation, but visual deficits and structural loss of retinal axonal and neuronal integrity can occur even without a history of optic neuritis. Interest in vision in multiple sclerosis is growing, partially in response to the development of sensitive visual function tests, structural markers such as optical coherence tomography and magnetic resonance imaging, and quality of life measures that give clinical meaning to the structure-function correlations that are unique to the afferent visual pathway. Abnormal eye movements also are common in multiple sclerosis, but quantitative assessment methods that can be applied in practice and clinical trials are not readily available. We summarize here a comprehensive literature search and the discussion at a recent international meeting of investigators involved in the development and study of visual outcomes in multiple sclerosis, which had, as its overriding goals, to review the state of the field and identify areas for future research. We review data and principles to help us understand the importance of vision as a model for outcomes assessment in clinical practice and therapeutic trials in multiple sclerosis. PMID:25433914

  14. Impact of Visual Field Loss on Health-Related Quality of Life in Glaucoma

    PubMed Central

    McKean-Cowdin, Roberta; Wang, Ying; Wu, Joanne; Azen, Stanley P.; Varma, Rohit

    2016-01-01

    Purpose To examine the association between health-related quality of life (HRQOL) and visual field (VF) loss in participants with open-angle glaucoma (OAG) in the Los Angeles Latino Eye Study (LALES). Design Population-based cross-sectional study. Participants Two hundred thirteen participants with OAG and 2821 participants without glaucoma or VF loss. Methods Participants in the LALES—a population-based prevalence study of eye disease in Latinos 40 years and older, residing in Los Angeles, California—underwent a detailed eye examination including an assessment of their VF using the Humphrey Automated Field Analyzer (Swedish interactive thresholding algorithm Standard 24-2). Open-angle glaucoma was determined by clinical examination. Mean deviation scores were used to assess severity of VF loss. Health-related QOL was assessed by the Medical Outcomes Study 12-item Short-Form Health Survey (SF-12) and 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). Linear regression and analysis of covariance were used to assess the relationship between HRQOL scores and VF loss after adjusting for sociodemographic variables and visual acuity. Main Outcome Measures The 25-item NEI-VFQ and SF-12 scores. Results A trend of worse NEI-VFQ-25 scores for most subscales was observed with worse VF loss (using both monocular and calculated binocular data). Open-angle glaucoma participants with VF loss had lower scores than participants with no VF loss. This association was also present in participants who were previously undiagnosed and untreated for OAG (N = 160). Participants with any central VF loss had lower NEI-VFQ-25 scores than those with unilateral or bilateral peripheral VF loss. There was no significant impact of severity or location of VF loss on SF-12 scores. Conclusion Greater severity of VF loss in persons with OAG impacts vision-related QOL. This impact was present in persons who were previously unaware that they had glaucoma. Prevention of VF loss in persons with glaucoma is likely to reduce loss of vision-related QOL. PMID:17997485

  15. Display device-adapted video quality-of-experience assessment

    NASA Astrophysics Data System (ADS)

    Rehman, Abdul; Zeng, Kai; Wang, Zhou

    2015-03-01

    Today's viewers consume video content from a variety of connected devices, including smart phones, tablets, notebooks, TVs, and PCs. This imposes significant challenges for managing video traffic efficiently to ensure an acceptable quality-of-experience (QoE) for the end users as the perceptual quality of video content strongly depends on the properties of the display device and the viewing conditions. State-of-the-art full-reference objective video quality assessment algorithms do not take into account the combined impact of display device properties, viewing conditions, and video resolution while performing video quality assessment. We performed a subjective study in order to understand the impact of aforementioned factors on perceptual video QoE. We also propose a full reference video QoE measure, named SSIMplus, that provides real-time prediction of the perceptual quality of a video based on human visual system behaviors, video content characteristics (such as spatial and temporal complexity, and video resolution), display device properties (such as screen size, resolution, and brightness), and viewing conditions (such as viewing distance and angle). Experimental results have shown that the proposed algorithm outperforms state-of-the-art video quality measures in terms of accuracy and speed.

  16. Biliary tract visualization using near-infrared imaging with indocyanine green during laparoscopic cholecystectomy: results of a systematic review.

    PubMed

    Vlek, S L; van Dam, D A; Rubinstein, S M; de Lange-de Klerk, E S M; Schoonmade, L J; Tuynman, J B; Meijerink, W J H J; Ankersmit, M

    2017-07-01

    Near-infrared imaging with indocyanine green (ICG) has been extensively investigated during laparoscopic cholecystectomy (LC). However, methods vary between studies, especially regarding patient selection, dosage and timing. The aim of this systematic review was to evaluate the potential of the near-infrared imaging technique with ICG to identify biliary structures during LC. A comprehensive systematic literature search was performed. Prospective trials examining the use of ICG during LC were included. Primary outcome was biliary tract visualization. Risk of bias was assessed using ROBINS-I. Secondly, a meta-analysis was performed comparing ICG to intraoperative cholangiography (IOC) for identification of biliary structures. GRADE was used to assess the quality of the evidence. Nineteen studies were included. Based upon the pooled data from 13 studies, cystic duct (Lusch et al. in J Endourol 28:261-266, 2014) visualization was 86.5% (95% CI 71.2-96.6%) prior to dissection of Calot's triangle with a 2.5-mg dosage of ICG and 96.5% (95% CI 93.9-98.4%) after dissection. The results were not appreciably different when the dosage was based upon bodyweight. There is moderate quality evidence that the CD is more frequently visualized using ICG than IOC (RR 1.16; 95% CI 1.00-1.35); however, this difference was not statistically significant. This systematic review provides equal results for biliary tract visualization with near-infrared imaging with ICG during LC compared to IOC. Near-infrared imaging with ICG has the potential to replace IOC for biliary mapping. However, methods of near-infrared imaging with ICG vary. Future research is necessary for optimization and standardization of the near-infrared ICG technique.

  17. Quality metrics in high-dimensional data visualization: an overview and systematization.

    PubMed

    Bertini, Enrico; Tatu, Andrada; Keim, Daniel

    2011-12-01

    In this paper, we present a systematization of techniques that use quality metrics to help in the visual exploration of meaningful patterns in high-dimensional data. In a number of recent papers, different quality metrics are proposed to automate the demanding search through large spaces of alternative visualizations (e.g., alternative projections or ordering), allowing the user to concentrate on the most promising visualizations suggested by the quality metrics. Over the last decade, this approach has witnessed a remarkable development but few reflections exist on how these methods are related to each other and how the approach can be developed further. For this purpose, we provide an overview of approaches that use quality metrics in high-dimensional data visualization and propose a systematization based on a thorough literature review. We carefully analyze the papers and derive a set of factors for discriminating the quality metrics, visualization techniques, and the process itself. The process is described through a reworked version of the well-known information visualization pipeline. We demonstrate the usefulness of our model by applying it to several existing approaches that use quality metrics, and we provide reflections on implications of our model for future research. © 2010 IEEE

  18. Bandwidth and SIMDUCE as simulator fidelity criteria

    NASA Technical Reports Server (NTRS)

    Key, David

    1992-01-01

    The potential application of two concepts from the new Handling Qualities Specification for Military Rotorcraft was discussed. The first concept is bandwidth, a measure of the dynamic response to control. The second is a qualitative technique developed for assessing the visual cue environment the pilot has in bad weather and at night. Simulated Day Usable Cue Environment (SIMDUCE) applies this concept to assessing the day cuing fidelity in the simulator.

  19. Blindness and Visual Impairment Profile and Rapid Assessment of Avoidable Blindness in South East Asia: Analysis of New Data. 2017 APAO Holmes Lecture.

    PubMed

    Das, Taraprasad

    2018-03-13

    The International Agency for Prevention of Blindness (IAPB) South East Asia region (SEAR) that consists of 11 countries contains 26% of the world's population (1,761,000,000). In this region 12 million are blind and 78.5 million are visually impaired. This amounts to 30% of global blindness and 32% of global visual impairment. Rapid assessment of avoidable blindness (RAAB) survey analysis. RAAB, either a repeat or a first time survey, was completed in 8 countries in this decade (2010 onwards). These include Bangladesh, Bhutan, India, Indonesia, Maldives, Sri Lanka, Thailand, and Timor Leste. Cataract is the principal cause of blindness and severe visual impairment in all countries. Refractive error is the principal cause of moderate visual impairment in 4 countries: Bangladesh, India, Maldives, and Sri Lanka; cataract continues to be the principal cause of moderate visual impairment in 4 other countries: Bhutan, Indonesia, Thailand, and Timor Leste. Outcome of cataract surgery is suboptimal in the Maldives and Timor Leste. Rigorous focus is necessary to improve cataract surgery outcomes and correction of refractive error without neglecting the quality of care. At the same time allowances must be made for care of the emerging causes of visual impairment and blindness such as glaucoma and posterior segment disorders, particularly diabetic retinopathy. Copyright 2018 Asia-Pacific Academy of Ophthalmology.

  20. Developing Matlab scripts for image analysis and quality assessment

    NASA Astrophysics Data System (ADS)

    Vaiopoulos, A. D.

    2011-11-01

    Image processing is a very helpful tool in many fields of modern sciences that involve digital imaging examination and interpretation. Processed images however, often need to be correlated with the original image, in order to ensure that the resulting image fulfills its purpose. Aside from the visual examination, which is mandatory, image quality indices (such as correlation coefficient, entropy and others) are very useful, when deciding which processed image is the most satisfactory. For this reason, a single program (script) was written in Matlab language, which automatically calculates eight indices by utilizing eight respective functions (independent function scripts). The program was tested in both fused hyperspectral (Hyperion-ALI) and multispectral (ALI, Landsat) imagery and proved to be efficient. Indices were found to be in agreement with visual examination and statistical observations.

  1. The environmental psychology of shopping: assessing the value of trees

    Treesearch

    Kathleen L. Wolf

    2007-01-01

    A multi-study research program has investigated how consumers respond to trees in various business settings in cities and towns. Some studies focused on central business districts, others tested perceptions along freeways and arterials. Results are remarkably consistent. Trees not only positively affect judgments of visual quality but,...

  2. VISUAL BEACH: SOFTWARE FOR ACHIEVING BEACH AESTHETIC AND PUBLIC HEALTH PROTECTION

    EPA Science Inventory

    The Beaches Environmental Assessment and Coastal Health Act of 2000 directs the EPA to assure that 100% of significant public beaches are managed by 2008. Under the Act EPA is developing a program to monitor beach water quality and strategies for timely notification of the public...

  3. Evaluation of angiogram visualization methods for fast and reliable aneurysm diagnosis

    NASA Astrophysics Data System (ADS)

    Lesar, Žiga; Bohak, Ciril; Marolt, Matija

    2015-03-01

    In this paper we present the results of an evaluation of different visualization methods for angiogram volumetric data-ray casting, marching cubes, and multi-level partition of unity implicits. There are several options available with ray-casting: isosurface extraction, maximum intensity projection and alpha compositing, each producing fundamentally different results. Different visualization methods are suitable for different needs, so this choice is crucial in diagnosis and decision making processes. We also evaluate visual effects such as ambient occlusion, screen space ambient occlusion, and depth of field. Some visualization methods include transparency, so we address the question of relevancy of this additional visual information. We employ transfer functions to map data values to color and transparency, allowing us to view or hide particular tissues. All the methods presented in this paper were developed using OpenCL, striving for real-time rendering and quality interaction. An evaluation has been conducted to assess the suitability of the visualization methods. Results show superiority of isosurface extraction with ambient occlusion effects. Visual effects may positively or negatively affect perception of depth, motion, and relative positions in space.

  4. Web-based decision support and visualization tools for water quality management in the Chesapeake Bay watershed

    USGS Publications Warehouse

    Mullinix, C.; Hearn, P.; Zhang, H.; Aguinaldo, J.

    2009-01-01

    Federal, State, and local water quality managers charged with restoring the Chesapeake Bay ecosystem require tools to maximize the impact of their limited resources. To address this need, the U.S. Geological Survey (USGS) and the Environmental Protection Agency's Chesapeake Bay Program (CBP) are developing a suite of Web-based tools called the Chesapeake Online Assessment Support Toolkit (COAST). The goal of COAST is to help CBP partners identify geographic areas where restoration activities would have the greatest effect, select the appropriate management strategies, and improve coordination and prioritization among partners. As part of the COAST suite of tools focused on environmental restoration, a water quality management visualization component called the Nutrient Yields Mapper (NYM) tool is being developed by USGS. The NYM tool is a web application that uses watershed yield estimates from USGS SPAtially Referenced Regressions On Watershed (SPARROW) attributes model (Schwarz et al., 2006) [6] to allow water quality managers to identify important sources of nitrogen and phosphorous within the Chesapeake Bay watershed. The NYM tool utilizes new open source technologies that have become popular in geospatial web development, including components such as OpenLayers and GeoServer. This paper presents examples of water quality data analysis based on nutrient type, source, yield, and area of interest using the NYM tool for the Chesapeake Bay watershed. In addition, we describe examples of map-based techniques for identifying high and low nutrient yield areas; web map engines; and data visualization and data management techniques.

  5. Therapist-Assisted Rehabilitation of Visual Function and Hemianopia after Brain Injury: Intervention Study on the Effect of the Neuro Vision Technology Rehabilitation Program.

    PubMed

    Rasmussen, Rune Skovgaard; Schaarup, Anne Marie Heltoft; Overgaard, Karsten

    2018-02-27

    Serious and often lasting vision impairments affect 30% to 35% of people following stroke. Vision may be considered the most important sense in humans, and even smaller permanent injuries can drastically reduce quality of life. Restoration of visual field impairments occur only to a small extent during the first month after brain damage, and therefore the time window for spontaneous improvements is limited. One month after brain injury causing visual impairment, patients usually will experience chronically impaired vision and the need for compensatory vision rehabilitation is substantial. The purpose of this study is to investigate whether rehabilitation with Neuro Vision Technology will result in a significant and lasting improvement in functional capacity in persons with chronic visual impairments after brain injury. Improving eyesight is expected to increase both physical and mental functioning, thus improving the quality of life. This is a prospective open label trial in which participants with chronic visual field impairments are examined before and after the intervention. Participants typically suffer from stroke or traumatic brain injury and will be recruited from hospitals and The Institute for the Blind and Partially Sighted. Treatment is based on Neuro Vision Technology, which is a supervised training course, where participants are trained in compensatory techniques using specially designed equipment. Through the Neuro Vision Technology procedure, the vision problems of each individual are carefully investigated, and personal data is used to organize individual training sessions. Cognitive face-to-face assessments and self-assessed questionnaires about both life and vision quality are also applied before and after the training. Funding was provided in June 2017. Results are expected to be available in 2020. Sample size is calculated to 23 participants. Due to age, difficulty in transport, and the time-consuming intervention, up to 25% dropouts are expected; thus, we aim to include at least 29 participants. This investigation will evaluate the effects of Neuro Vision Technology therapy on compensatory vision rehabilitation. Additionally, quality of life and cognitive improvements associated to increased quality of life will be explored. ClinicalTrials.gov NCT03160131; https://clinicaltrials.gov/ct2/show/NCT03160131 (Archived by WebCite at http://www.webcitation.org/6x3f5HnCv). ©Rune Skovgaard Rasmussen, Anne Marie Heltoft Schaarup, Karsten Overgaard. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 27.02.2018.

  6. Blast exposure and dual sensory impairment: an evidence review and integrated rehabilitation approach.

    PubMed

    Saunders, Gabrielle H; Echt, Katharina V

    2012-01-01

    Combat exposures to blast can result in both peripheral damage to the ears and eyes and central damage to the auditory and visual processing areas in the brain. The functional effects of the latter include visual, auditory, and cognitive processing difficulties that manifest as deficits in attention, memory, and problem solving--symptoms similar to those seen in individuals with visual and auditory processing disorders. Coexisting damage to the auditory and visual system is referred to as dual sensory impairment (DSI). The number of Operation Iraqi Freedom/Operation Enduring Freedom Veterans with DSI is vast; yet currently no established models or guidelines exist for assessment, rehabilitation, or service-delivery practice. In this article, we review the current state of knowledge regarding blast exposure and DSI and outline the many unknowns in this area. Further, we propose a model for clinical assessment and rehabilitation of blast-related DSI that includes development of a coordinated team-based approach to target activity limitations and participation restrictions in order to enhance reintegration, recovery, and quality of life.

  7. The Aeroflex: A Bicycle for Mobile Air Quality Measurements

    PubMed Central

    Elen, Bart; Peters, Jan; Van Poppel, Martine; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2013-01-01

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. PMID:23262484

  8. The Aeroflex: a bicycle for mobile air quality measurements.

    PubMed

    Elen, Bart; Peters, Jan; Poppel, Martine Van; Bleux, Nico; Theunis, Jan; Reggente, Matteo; Standaert, Arnout

    2012-12-24

    Fixed air quality stations have limitations when used to assess people's real life exposure to air pollutants. Their spatial coverage is too limited to capture the spatial variability in, e.g., an urban or industrial environment. Complementary mobile air quality measurements can be used as an additional tool to fill this void. In this publication we present the Aeroflex, a bicycle for mobile air quality monitoring. The Aeroflex is equipped with compact air quality measurement devices to monitor ultrafine particle number counts, particulate mass and black carbon concentrations at a high resolution (up to 1 second). Each measurement is automatically linked to its geographical location and time of acquisition using GPS and Internet time. Furthermore, the Aeroflex is equipped with automated data transmission, data pre-processing and data visualization. The Aeroflex is designed with adaptability, reliability and user friendliness in mind. Over the past years, the Aeroflex has been successfully used for high resolution air quality mapping, exposure assessment and hot spot identification. 

  9. [Quality of life in visual impaired children treated for Early Visual Stimulation].

    PubMed

    Messa, Alcione Aparecida; Nakanami, Célia Regina; Lopes, Marcia Caires Bestilleiro

    2012-01-01

    To evaluate the quality of life in visually impaired children followed in the Early Visual Stimulation Ambulatory of Unifesp in two moments, before and after rehabilitational intervention of multiprofessional team. A CVFQ quality of life questionnaire was used. This instrument has a version for less than three years old children and another one for children older than three years (three to seven years) divided in six subscales: General health, General vision health, Competence, Personality, Family impact and Treatment. The correlation between the subscales on two moments was significant. There was a statistically significant difference in general vision health (p=0,029) and other important differences obtained in general health, family impact and quality of life general score. The questionnaire showed to be effective in order to measure the quality of life related to vision on families followed on this ambulatory. The multidisciplinary interventions provided visual function and familiar quality of life improvement. The quality of life related to vision in children followed in Early Visual Stimulation Ambulatory of Unifesp showed a significant improvement on general vision health.

  10. Automated Assessment of Dynamic Knee Valgus and Risk of Knee Injury During the Single Leg Squat

    PubMed Central

    Lee, Alexander; Raina, Sachin; Kulić, Dana

    2017-01-01

    Many clinical assessment protocols of the lower limb rely on the evaluation of functional movement tests such as the single leg squat (SLS), which are often assessed visually. Visual assessment is subjective and depends on the experience of the clinician. In this paper, an inertial measurement unit (IMU)-based method for automated assessment of squat quality is proposed to provide clinicians with a quantitative measure of SLS performance. A set of three IMUs was used to estimate the joint angles, velocities, and accelerations of the squatting leg. Statistical time domain features were generated from these measurements. The most informative features were used for classifier training. A data set of SLS performed by healthy participants was collected and labeled by three expert clinical raters using two different labeling criteria: “observed amount of knee valgus” and “overall risk of injury”. The results showed that both flexion at the hip and knee, as well as hip and ankle internal rotation are discriminative features, and that participants with “poor” squats bend the hip and knee less than those with better squat performance. Furthermore, improved classification performance is achieved for females by training separate classifiers stratified by gender. Classification results showed excellent accuracy, 95.7 % for classifying squat quality as “poor” or “good” and 94.6% for differentiating between high and no risk of injury. PMID:29204327

  11. Visual Arts Education improves self-esteem for persons with dementia and reduces caregiver burden: A randomized controlled trial.

    PubMed

    Richards, Allan G; Tietyen, Ann C; Jicha, Gregory A; Bardach, Shoshana H; Schmitt, Frederick A; Fardo, David W; Kryscio, Richard J; Abner, Erin L

    2018-01-01

    A Visual Arts Education program was tested among 26 pairs of persons with dementia and their caregivers. Pairs were randomized to Visual Arts Education or control groups, and each group met once per week for two months (8 weeks) to participate in activities with a trained arts instructor. Groups were assessed at baseline, two months, and six months. The Visual Arts Education group received instruction and produced a different type of artistic work each week. The pedagogical strategy was designed so that each activity was increasingly novel, challenging, and complex. The control group viewed slide shows, participated in discussions about art, and made paintings. At the six-month follow-up, significant improvements in caregiver burden and self-esteem for the persons with dementia were found in the Visual Arts Education group. The Visual Arts Education pedagogical approach shows the potential for effectiveness for improving quality of life for persons with dementia and their caregivers.

  12. Skin lipids of the striped plateau lizard (Sceloporus virgatus) correlate with female receptivity and reproductive quality alongside visual ornaments.

    PubMed

    Goldberg, Jay K; Wallace, Alisa K; Weiss, Stacey L

    2017-09-14

    Sex pheromones can perform a variety of functions ranging from revealing the location of suitable mates to being honest signals of mate quality, and they are used in the mate selection process by many species of reptile. In this study, we determined whether the skin lipids of female striped plateau lizards (Sceloporus virgatus) can predict the reproductive quality of females, thereby having the potential to serve as pheromones. Using gas chromatography/mass spectrometry, we identified 17 compounds present in skin lipids of female lizards. Using principal component analysis to compare the skin lipid profile of receptive and non-receptive females, we determined that an uncharacterized compound may allow for chemical identification of receptive mates. We also compared extracted principal components to measures of female fitness and reproductive qualities and found that the level of two 18 carbon fatty acids present in a female's skin lipids may indicate her clutch size. Finally, we compared the information content of the skin lipids to that of female-specific color ornaments to assess whether chemical and visual cues transmit different information or not. We found that the chroma of a female's orange throat patch is also related to her clutch size, suggesting that chemical signals may reinforce the information communicated by visual ornamentation in this species which would support the "backup signals" hypothesis for multiple signals.

  13. Skin lipids of the striped plateau lizard ( Sceloporus virgatus) correlate with female receptivity and reproductive quality alongside visual ornaments

    NASA Astrophysics Data System (ADS)

    Goldberg, Jay K.; Wallace, Alisa K.; Weiss, Stacey L.

    2017-10-01

    Sex pheromones can perform a variety of functions ranging from revealing the location of suitable mates to being honest signals of mate quality, and they are used in the mate selection process by many species of reptile. In this study, we determined whether the skin lipids of female striped plateau lizards ( Sceloporus virgatus) can predict the reproductive quality of females, thereby having the potential to serve as pheromones. Using gas chromatography/mass spectrometry, we identified 17 compounds present in skin lipids of female lizards. Using principal component analysis to compare the skin lipid profile of receptive and non-receptive females, we determined that an uncharacterized compound may allow for chemical identification of receptive mates. We also compared extracted principal components to measures of female fitness and reproductive qualities and found that the level of two 18 carbon fatty acids present in a female's skin lipids may indicate her clutch size. Finally, we compared the information content of the skin lipids to that of female-specific color ornaments to assess whether chemical and visual cues transmit different information or not. We found that the chroma of a female's orange throat patch is also related to her clutch size, suggesting that chemical signals may reinforce the information communicated by visual ornamentation in this species which would support the "backup signals" hypothesis for multiple signals.

  14. Dermatography (Medical Tattooing) for Scars and Skin Grafts in Head and Neck Patients to Improve Appearance and Quality of Life.

    PubMed

    Drost, Brigitte H; van de Langenberg, Rick; Manusama, Olivia R; Janssens, A Soe; Sikorska, Karolina; Zuur, C Lot; Klop, Willem M C; Lohuis, Peter J F M

    2017-01-01

    Dermatography (medical tattooing) is often overlooked as an adjuvant procedure to improve color mismatch in the head and neck area, and its effect on patient satisfaction and quality of life has not been evaluated, to our knowledge. To analyze the effect of dermatography on the subjective perception of the appearance of scars and skin grafts and the quality of life in head and neck patients. Case series of patients undergoing dermatography at the Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, between July 1, 2007, and April 1, 2015. Participants were invited to respond to 2 questionnaires measuring their scar or graft appearance and their quality of life before and after dermatography as an adjuvant treatment for benign or malignant head and neck tumors. Use of dermatography. Two questionnaires evaluating a visual analog scale score (range, 0-10) and multiple questions on a 5-point scale focusing on satisfaction with the appearance and the quality of life. Among 76 patients, 56 (74%) were included in the study. The mean (SD) age of the study cohort was 56.5 (16.0) years, and 42 (75%) were female. The mean improvement in scar or skin graft perception on the visual analog scale of the modified Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty before and after dermatography was 4 points. On the modified Patient Scar Assessment Questionnaire, uniform improvement of approximately 1 point across 9 questions was observed. The answers to all patient satisfaction and quality-of-life questions on both questionnaires improved significantly after dermatography. Dermatography is an effectual adjuvant procedure to improve the subjective perception of scar and skin graft appearance and the quality of life in head and neck patients. 4.

  15. The Quality of Medicines Used in Children and Supplied by Private Pharmaceutical Wholesalers in Kinshasa, Democratic Republic of Congo: A Prospective Survey

    PubMed Central

    Schiavetti, Benedetta; Wynendaele, Evelien; De Spiegeleer, Bart; Mbinze, Geremie J.; Kalenda, Nicodème; Marini, Roland; Melotte, Vera; Hasker, Epco; Meessen, Bruno; Ravinetto, Raffaella; Van der Elst, Josiane; Mutolo Ngeleka, Daniel

    2018-01-01

    Abstract. Poor-quality medicines are a threat to public health in many low- and middle-income countries, and prospective surveys are needed to inform corrective actions. Therefore, we conducted a cross-sectional survey on a sample of products used for children and available in the private market in Kinshasa, Democratic Republic Congo: amoxicillin (AX) and artemether/lumefantrine (AL), powders for suspension, and paracetamol (PC) tablets 500 mg. Overall, 417 products were covertly purchased from 61 wholesalers. To obtain a representative sample, the products were weighted on their market shares and a subset of 239 samples was randomly extracted to undergo in-depth visual inspection locally, and they were chemically assessed at two accredited laboratories in Belgium. Samples were defined of “poor-quality” if they failed to comply with at least one specification of the International Pharmacopoeia (for AL) or United States Pharmacopoeia 37 (for AX and PC). Results are reported according to the Medicine Quality Assessment Reporting Guideline. The visual inspection detected nonconformities in the aspects of antimalarial powders for suspension, and poor-quality labels across all medicine types. According to chemical analysis, 27.2% samples were of poor quality and 59.5% of AL samples were underdosed in artemether. Poor quality was more frequent for locally manufactured antimalarials (83.3%, P = 0.021; 86.4%, P = 0.022) and PC (4.8%, P = 0.000). The poor quality of the surveyed products may decrease the treatment’s efficacy and favor the development of resistances to antimalarials. It is hoped that these findings may guide the corrective actions of the Democratic Republic of Congo Regulatory Authority, which was the main partner in the research. PMID:29313479

  16. Effects of multifocal soft contact lenses used to slow myopia progression on quality of vision in young adults.

    PubMed

    Kang, Pauline; McAlinden, Colm; Wildsoet, Christine F

    2017-02-01

    To assess the effects of multifocal soft contact lenses (MF SCLs) used for myopia control on visual acuity (VA) and subjective quality of vision. Twenty-four young adult myopes had baseline high and low-contrast VAs and refractions measured and quality of vision assessed by the Quality of Vision (QoV) questionnaire with single vision SCLs. Additional VA and QoV questionnaire data were collected immediately after subjects were fitted with Proclear MF SCLs and again after a 2-week adaptation period of daily lens wear. Data were collected for two MF SCL designs, incorporating +1.50 and +3.00 D peripheral near additions, with a week washout period allowed between the two lens trials. High- and low-contrast VAs were initially reduced with both MF SCL designs, but subsequently improved to be not significantly reduced in the case of high-contrast VA by the end of the 2-week adaptation period. The quality of vision was also reduced, more so with the +3.00 D MF SCL. Quality of Vision (QoV) scores describing frequency, severity and bothersome nature of visual symptoms indicated symptoms worsening rather than resolving over the 2-week period, particularly so with the +3.00 D MF SCL. Low and high add MF SCLs adversely affected vision on initial insertion, with sustained effects on low-contrast VA and QoV scores but not high-contrast VA. Thus, high-contrast VA is not a suitable surrogate for quality of vision. In prescribing MF SCLs for myopia control, clinicians should educate patients about these effects on vision. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Psychological Health and Overweight and Obesity Among High Stressed Work Environments

    PubMed Central

    Faghri, Pouran D; Mignano, Christina; Huedo- Medina, Tania B; Cherniack, Martin

    2016-01-01

    Correctional employees are recognized to underreport stress and stress symptoms and are known to have a culture that discourages appearing “weak” and seeking psychiatric help. This study assesses underreporting of stress and emotions. Additionally, it evaluates the relationships between stress and emotions on health behaviors. Correctional employees (n=317) completed physical assessments to measure body mass index (BMI), and surveys to assess perceived stress, emotions, and health behavior (diet, exercise, and sleep quality). Stress and emotion survey items were evaluated for under-reporting via skewness, kurtosis, and visual assessment of histograms. Structural equation modeling evaluated relationships between stress/emotion and health behaviors. Responses to stress and negatively worded emotions were non-normally distributed whereas responses to positively-worded emotions were normally distributed. Emotion predicted diet, exercise, and sleep quality whereas stress predicted only sleep quality. As stress was a poor predictor of health behaviors and responses to stress and negatively worded emotions were non-normally distributed it may suggests correctional employees are under-reporting stress and negative emotions. PMID:27547828

  18. Psychological Health and Overweight and Obesity Among High Stressed Work Environments.

    PubMed

    Faghri, Pouran D; Mignano, Christina; Huedo-Medina, Tania B; Cherniack, Martin

    2015-07-01

    Correctional employees are recognized to underreport stress and stress symptoms and are known to have a culture that discourages appearing "weak" and seeking psychiatric help. This study assesses underreporting of stress and emotions. Additionally, it evaluates the relationships between stress and emotions on health behaviors. Correctional employees (n=317) completed physical assessments to measure body mass index (BMI), and surveys to assess perceived stress, emotions, and health behavior (diet, exercise, and sleep quality). Stress and emotion survey items were evaluated for under-reporting via skewness, kurtosis, and visual assessment of histograms. Structural equation modeling evaluated relationships between stress/emotion and health behaviors. Responses to stress and negatively worded emotions were non-normally distributed whereas responses to positively-worded emotions were normally distributed. Emotion predicted diet, exercise, and sleep quality whereas stress predicted only sleep quality. As stress was a poor predictor of health behaviors and responses to stress and negatively worded emotions were non-normally distributed it may suggests correctional employees are under-reporting stress and negative emotions.

  19. A comparison of the sensitivity of EQ-5D, SF-6D and TTO utility values to changes in vision and perceived visual function in patients with primary open-angle glaucoma

    PubMed Central

    2012-01-01

    Background Economic viability of treatments for primary open-angle glaucoma (POAG) should be assessed objectively to prioritise health care interventions. This study aims to identify the methods for eliciting utility values (UVs) most sensitive to differences in visual field and visual functioning in patients with POAG. As a secondary objective, the dimensions of generic health-related and vision-related quality of life most affected by progressive vision loss will be identified. Methods A total of 132 POAG patients were recruited. Three sets of utility values (EuroQoL EQ-5D, Short Form SF-6D, Time Trade Off) and a measure of perceived visual functioning from the National Eye Institute Visual Function Questionnaire (VFQ-25) were elicited during face-to-face interviews. The sensitivity of UVs to differences in the binocular visual field, visual acuity and visual functioning measures was analysed using non-parametric statistical methods. Results Median utilities were similar across Integrated Visual Field score quartiles for EQ-5D (P = 0.08) whereas SF-6D and Time-Trade-Off UVs significantly decreased (p = 0.01 and p = 0.001, respectively). The VFQ-25 score varied across Integrated Visual Field and binocular visual acuity groups and was associated with all three UVs (P ≤ 0.001); most of its vision-specific sub-scales were associated with the vision markers. The most affected dimension was driving. A relationship with vision markers was found for the physical component of SF-36 and not for any dimension of EQ-5D. Conclusions The Time-Trade-Off was more sensitive than EQ-5D and SF-6D to changes in vision and visual functioning associated with glaucoma progression but could not measure quality of life changes in the mildest disease stages. PMID:22909264

  20. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings.

    PubMed

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel; Molnár, Vieroslav

    2018-03-21

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015-2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects.

  1. Restoration of Worn Movable Bridge Props with Use of Bronze Claddings

    PubMed Central

    Viňáš, Ján; Vrabeľ, Marek; Greš, Miroslav; Brezina, Jakub; Sabadka, Dušan; Fedorko, Gabriel

    2018-01-01

    This article examined the possibility of using CuSn6P claddings in sliding bearing renovation of movable pontoon bridge props. The bronze layer was welded on cylinders of the high-strength steel S355J0WP EN 10155-93, in an inert atmosphere using an automated welding method (gas tungsten arc welding). Pulsed arc welding was used to minimize the effects of heat on the cladding area, while also accounting for the differences in the physical properties of the joined metals. The sliding bearing was created in two layers. The quality of the cladding layer was evaluated by nondestructive and/or destructive tests. The quality of the surface was assessed by visual inspection (visual testing) in accordance with the EN ISO 17637 standard. The quality of the claddings was evaluated by metallographic analysis, performed using light microscopy. The microhardness values of a few weld areas were determined by Vickers tests, performed according to the EN ISO 9015–2 standard. The analyses confirmed that the welding parameters and filler material used resulted in high-quality weld joints with no internal (subsurface) or metallurgical defects. PMID:29561762

  2. Beyond image quality: designing engaging interactions with digital products

    NASA Astrophysics Data System (ADS)

    de Ridder, Huib; Rozendaal, Marco C.

    2008-02-01

    Ubiquitous computing (or Ambient Intelligence) promises a world in which information is available anytime anywhere and with which humans can interact in a natural, multimodal way. In such world, perceptual image quality remains an important criterion since most information will be displayed visually, but other criteria such as enjoyment, fun, engagement and hedonic quality are emerging. This paper deals with engagement, the intrinsically enjoyable readiness to put more effort into exploring and/or using a product than strictly required, thus attracting and keeping user's attention for a longer period of time. The impact of the experienced richness of an interface, both visually and degree of possible manipulations, was investigated in a series of experiments employing game-like user interfaces. This resulted in the extension of an existing conceptual framework relating engagement to richness by means of two intermediating variables, namely experienced challenge and sense of control. Predictions from this revised framework are evaluated against results of an earlier experiment assessing the ergonomic and hedonic qualities of interactive media. Test material consisted of interactive CD-ROM's containing presentations of three companies for future customers.

  3. Multiple Image Arrangement for Subjective Quality Assessment

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Zhai, Guangtao

    2017-12-01

    Subjective quality assessment serves as the foundation for almost all visual quality related researches. Size of the image quality databases has expanded from dozens to thousands in the last decades. Since each subjective rating therein has to be averaged over quite a few participants, the ever-increasing overall size of those databases calls for an evolution of existing subjective test methods. Traditional single/double stimulus based approaches are being replaced by multiple image tests, where several distorted versions of the original one are displayed and rated at once. And this naturally brings upon the question of how to arrange those multiple images on screen during the test. In this paper, we answer this question by performing subjective viewing test with eye tracker for different types arrangements. Our research indicates that isometric arrangement imposes less duress on participants and has more uniform distribution of eye fixations and movements and therefore is expected to generate more reliable subjective ratings.

  4. [The effectiveness of therapeutic touch on pain, depression and sleep in patients with chronic pain: clinical trial].

    PubMed

    Marta, Ilda Estefani Ribeiro; Baldan, Sueli Santiago; Berton, Ani Fabiana; Pavam, Michele; da Silva, Maria Júlia Paes

    2010-12-01

    This research aimed to check the effectiveness of Therapeutic Touch on decreased pain intensity, depression self-assessment scores and improved sleep quality. A clinical before-after trial is presented. The study was carried out at a Basic Health Unit in Fernandópolis, SP-Brazil, involving 30 elderly patients with chronic non-oncologic pain who received 8 sessions of Therapeutic Touch in accordance with the Krieger-Kunz method. The Visual Analogue Scale for pain was applied before and after each session, and Beck Depression Inventory and the Pittsburgh Sleep Quality Index before the first and after the last session. Data analysis showed a significant decrease (p < 0.05) in pain intensity, depression self-assessment scores and the sleep quality index. It is concluded that the Therapeutic Touch was effective to decrease pain intensity and depressive attitudes and symptoms, as well as to improve sleep quality.

  5. Klickitat Cogeneration Project : Final Environmental Assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration; Klickitat Energy Partners

    1994-09-01

    To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2)more » impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI (Finding of No Significant Impact).« less

  6. Visualizing Topic Flow in Students' Essays

    ERIC Educational Resources Information Center

    O'Rourke, Stephen T.; Calvo, Rafael A.; McNamara, Danielle S.

    2011-01-01

    Visualizing how the parts of a document relate to each other and producing automatically generated quality measures that people can understand are means that writers can use to improve the quality of their compositions. This paper presents a novel document visualization technique and a measure of quality based on the average semantic distance…

  7. Driving with Binocular Visual Field Loss? A Study on a Supervised On-Road Parcours with Simultaneous Eye and Head Tracking

    PubMed Central

    Aehling, Kathrin; Heister, Martin; Rosenstiel, Wolfgang; Schiefer, Ulrich; Papageorgiou, Elena

    2014-01-01

    Post-chiasmal visual pathway lesions and glaucomatous optic neuropathy cause binocular visual field defects (VFDs) that may critically interfere with quality of life and driving licensure. The aims of this study were (i) to assess the on-road driving performance of patients suffering from binocular visual field loss using a dual-brake vehicle, and (ii) to investigate the related compensatory mechanisms. A driving instructor, blinded to the participants' diagnosis, rated the driving performance (passed/failed) of ten patients with homonymous visual field defects (HP), including four patients with right (HR) and six patients with left homonymous visual field defects (HL), ten glaucoma patients (GP), and twenty age and gender-related ophthalmologically healthy control subjects (C) during a 40-minute driving task on a pre-specified public on-road parcours. In order to investigate the subjects' visual exploration ability, eye movements were recorded by means of a mobile eye tracker. Two additional cameras were used to monitor the driving scene and record head and shoulder movements. Thus this study is novel as a quantitative assessment of eye movements and an additional evaluation of head and shoulder was performed. Six out of ten HP and four out of ten GP were rated as fit to drive by the driving instructor, despite their binocular visual field loss. Three out of 20 control subjects failed the on-road assessment. The extent of the visual field defect was of minor importance with regard to the driving performance. The site of the homonymous visual field defect (HVFD) critically interfered with the driving ability: all failed HP subjects suffered from left homonymous visual field loss (HL) due to right hemispheric lesions. Patients who failed the driving assessment had mainly difficulties with lane keeping and gap judgment ability. Patients who passed the test displayed different exploration patterns than those who failed. Patients who passed focused longer on the central area of the visual field than patients who failed the test. In addition, patients who passed the test performed more glances towards the area of their visual field defect. In conclusion, our findings support the hypothesis that the extent of visual field per se cannot predict driving fitness, because some patients with HVFDs and advanced glaucoma can compensate for their deficit by effective visual scanning. Head movements appeared to be superior to eye and shoulder movements in predicting the outcome of the driving test under the present study scenario. PMID:24523869

  8. Ergonomics improvements of the visual inspection process in a printed circuit assembly factory.

    PubMed

    Yeow, Paul H P; Sen, Rabindra Nath

    2004-01-01

    An ergonomics improvement study was conducted on the visual inspection process of a printed circuit assembly (PCA) factory. The process was studied through subjective assessment and direct observation. Three problems were identified: operators' eye problems, insufficient time for inspection and ineffective visual inspection. These problems caused a huge yearly rejection cost of US 298,240 dollars, poor quality, customer dissatisfaction and poor occupational health and safety. Ergonomics interventions were made to rectify the problems: reduced usage of a magnifying glass, the use of less glaring inspection templates, inspection of only electrically non-tested components and introduction of a visual inspection sequence. The interventions produced savings in rejection cost, reduced operators' eye strain, headaches and watery eyes, lowered the defect percentage at customers' sites and increased the factory's productivity and customer satisfaction.

  9. Alterations in the inferior longitudinal fasciculus in autism and associations with visual processing: a diffusion-weighted MRI study.

    PubMed

    Boets, Bart; Van Eylen, Lien; Sitek, Kevin; Moors, Pieter; Noens, Ilse; Steyaert, Jean; Sunaert, Stefan; Wagemans, Johan

    2018-01-01

    One of the most reported neural features of autism spectrum disorder (ASD) is the alteration of multiple long-range white matter fiber tracts, as assessed by diffusion-weighted imaging and indexed by reduced fractional anisotropy (FA). Recent methodological advances, however, have shown that this same pattern of reduced FA may be an artifact resulting from excessive head motion and poorer data quality and that aberrant structural connectivity in children with ASD is confined to the right inferior longitudinal fasciculus (ILF). This study aimed at replicating the observation of reduced FA along the right ILF in ASD, while controlling for group differences in head motion and data quality. In addition, we explored associations between reduced FA in the right ILF and quantitative ASD characteristics, and the involvement of the right ILF in visual processing, which is known to be altered in ASD. Global probabilistic tractography was performed on diffusion-weighted imaging data of 17 adolescent boys with ASD and 17 typically developing boys, matched for age, performance IQ, handedness, and data quality. Four tasks were administered to measure various aspects of visual information processing, together with questionnaires assessing ASD characteristics. Group differences were examined and the neural data were integrated with previously published findings using Bayesian statistics to quantify evidence for replication and to pool data and thus increase statistical power. (Partial) correlations were calculated to investigate associations between measures. The ASD group showed consistently reduced FA only in the right ILF and slower performance on the visual search task. Bayesian statistics pooling data across studies confirmed that group differences in FA were confined to the right ILF only, with the evidence for altered FA in the left ILF being indecisive. Lower FA in the right ILF tended to covary with slower visual search and a more fragmented part-oriented processing style. Individual differences in FA of the right ILF were not reliably associated with the severity of ASD traits after controlling for clinical status. Our findings support the growing evidence for reduced FA along a specific fiber tract in ASD, the right ILF.

  10. The use of UV-visible reflectance spectroscopy as an objective tool to evaluate pearl quality.

    PubMed

    Agatonovic-Kustrin, Snezana; Morton, David W

    2012-07-01

    Assessing the quality of pearls involves the use of various tools and methods, which are mainly visual and often quite subjective. Pearls are normally classified by origin and are then graded by luster, nacre thickness, surface quality, size, color and shape. The aim of this study was to investigate the capacity of Artificial Neural Networks (ANNs) to classify and estimate the quality of 27 different pearls from their UV-Visible spectra. Due to the opaque nature of pearls, spectroscopy measurements were performed using the Diffuse Reflectance UV-Visible spectroscopy technique. The spectra were acquired at two different locations on each pearl sample in order to assess surface homogeneity. The spectral data (inputs) were smoothed to reduce the noise, fed into ANNs and correlated to the pearl's quality/grading criteria (outputs). The developed ANNs were successful in predicting pearl type, mollusk growing species, possible luster and color enhancing, donor condition/type, recipient/host color, donor color, pearl luster, pearl color, origin. The results of this study shows that the developed UV-Vis spectroscopy-ANN method could be used as a more objective method of assessing pearl quality (grading) and may become a valuable tool for the pearl grading industry.

  11. Color Analysis

    NASA Astrophysics Data System (ADS)

    Wrolstad, Ronald E.; Smith, Daniel E.

    Color, flavor, and texture are the three principal quality attributes that determine food acceptance, and color has a far greater influence on our judgment than most of us appreciate. We use color to determine if a banana is at our preferred ripeness level, and a discolored meat product can warn us that the product may be spoiled. The marketing departments of our food corporations know that, for their customers, the color must be "right." The University of California Davis scorecard for wine quality designates four points out of 20, or 20% of the total score, for color and appearance (1). Food scientists who establish quality control specifications for their product are very aware of the importance of color and appearance. While subjective visual assessment and use of visual color standards are still used in the food industry, instrumental color measurements are extensively employed. Objective measurement of color is desirable for both research and industrial applications, and the ruggedness, stability, and ease of use of today's color measurement instruments have resulted in their widespread adoption.

  12. Efficiency analysis of color image filtering

    NASA Astrophysics Data System (ADS)

    Fevralev, Dmitriy V.; Ponomarenko, Nikolay N.; Lukin, Vladimir V.; Abramov, Sergey K.; Egiazarian, Karen O.; Astola, Jaakko T.

    2011-12-01

    This article addresses under which conditions filtering can visibly improve the image quality. The key points are the following. First, we analyze filtering efficiency for 25 test images, from the color image database TID2008. This database allows assessing filter efficiency for images corrupted by different noise types for several levels of noise variance. Second, the limit of filtering efficiency is determined for independent and identically distributed (i.i.d.) additive noise and compared to the output mean square error of state-of-the-art filters. Third, component-wise and vector denoising is studied, where the latter approach is demonstrated to be more efficient. Fourth, using of modern visual quality metrics, we determine that for which levels of i.i.d. and spatially correlated noise the noise in original images or residual noise and distortions because of filtering in output images are practically invisible. We also demonstrate that it is possible to roughly estimate whether or not the visual quality can clearly be improved by filtering.

  13. Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom

    NASA Astrophysics Data System (ADS)

    Vodovatov, A. V.; Kamishanskaya, I. G.; Drozdov, A. A.; Bernhardsson, C.

    2017-02-01

    The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.

  14. Object Recognition in Mental Representations: Directions for Exploring Diagnostic Features through Visual Mental Imagery.

    PubMed

    Roldan, Stephanie M

    2017-01-01

    One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation.

  15. Retrospective comparison of three-dimensional imaging sequences in the visualization of posterior fossa cranial nerves.

    PubMed

    Ors, Suna; Inci, Ercan; Turkay, Rustu; Kokurcan, Atilla; Hocaoglu, Elif

    2017-12-01

    To compare efficancy of three-dimentional SPACE (sampling perfection with application-optimized contrasts using different flip-angle evolutions) and CISS (constructive interference in steady state) sequences in the imaging of the cisternal segments of cranial nerves V-XII. Temporal MRI scans from 50 patients (F:M ratio, 27:23; mean age, 44.5±15.9 years) admitted to our hospital with vertigo, tinnitus, and hearing loss were retrospectively analyzed. All patients had both CISS and SPACE sequences. Quantitative analysis of SPACE and CISS sequences was performed by measuring the ventricle-to-parenchyma contrast-to-noise ratio (CNR). Qualitative analysis of differences in visualization capability, image quality, and severity of artifacts was also conducted. A score ranging 'no artefact' to 'severe artefacts and unreadable' was used for the assessment of artifacts and from 'not visualized' to 'completely visualized' for the assesment of image quality, respectively. The distribution of variables was controlled by the Kolmogorov-Smirnov test. Samples t-test and McNemar's test were used to determine statistical significance. Rates of visualization of posterior fossa cranial nerves in cases of complete visualization were as follows: nerve V (100% for both sequences), nerve VI (94% in SPACE, 86% in CISS sequences), nerves VII-VIII (100% for both sequences), IX-XI nerve complex (96%, 88%); nerve XII (58%, 46%) (p<0.05). SPACE sequences showed fewer artifacts than CISS sequences (p<0.002). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Object Recognition in Mental Representations: Directions for Exploring Diagnostic Features through Visual Mental Imagery

    PubMed Central

    Roldan, Stephanie M.

    2017-01-01

    One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation. PMID:28588538

  17. A strategy to optimize CT pediatric dose with a visual discrimination model

    NASA Astrophysics Data System (ADS)

    Gutierrez, Daniel; Gudinchet, François; Alamo-Maestre, Leonor T.; Bochud, François O.; Verdun, Francis R.

    2008-03-01

    Technological developments of computed tomography (CT) have led to a drastic increase of its clinical utilization, creating concerns about patient exposure. To better control dose to patients, we propose a methodology to find an objective compromise between dose and image quality by means of a visual discrimination model. A GE LightSpeed-Ultra scanner was used to perform the acquisitions. A QRM 3D low contrast resolution phantom (QRM - Germany) was scanned using CTDI vol values in the range of 1.7 to 103 mGy. Raw data obtained with the highest CTDI vol were afterwards processed to simulate dose reductions by white noise addition. Noise realism of the simulations was verified by comparing normalized noise power spectra aspect and amplitudes (NNPS) and standard deviation measurements. Patient images were acquired using the Diagnostic Reference Levels (DRL) proposed in Switzerland. Noise reduction was then simulated, as for the QRM phantom, to obtain five different CTDI vol levels, down to 3.0 mGy. Image quality of phantom images was assessed with the Sarnoff JNDmetrix visual discrimination model and compared to an assessment made by means of the ROC methodology, taken as a reference. For patient images a similar approach was taken but using as reference the Visual Grading Analysis (VGA) method. A relationship between Sarnoff JNDmetrix and ROC results was established for low contrast detection in phantom images, demonstrating that the Sarnoff JNDmetrix can be used for qualification of images with highly correlated noise. Patient image qualification showed a threshold of conspicuity loss only for children over 35 kg.

  18. 75 FR 59716 - Draft Toxicological Review of Urea: In Support of Summary Information on the Integrated Risk...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... environment. Through the IRIS Program, EPA provides the highest quality science- based human health... external review draft human health assessment titled, ``Toxicological Review of Urea: In Support of Summary... register, please indicate if you will need audio-visual equipment (e.g., laptop computer and slide...

  19. VELMA Ecohydrological Model, Version 2.0 -- Analyzing Green Infrastructure Options for Enhancing Water Quality and Ecosystem Service Co-Benefits

    EPA Science Inventory

    This 2-page factsheet describes an enhanced version (2.0) of the VELMA eco-hydrological model. VELMA – Visualizing Ecosystem Land Management Assessments – has been redesigned to assist communities, land managers, policy makers and other decision makers in evaluataing the effecti...

  20. Health related quality of life and perception of deformity in patients with adolescent idiopathic scoliosis.

    PubMed

    Çolak, Tuğba Kuru; Akgül, Turgut; Çolak, Ilker; Dereli, Elif Elçin; Chodza, Mehmet; Dikici, Fatih

    2017-01-01

    Quality of life and cosmethic appearance have gained importance as outcomes in AIS treatment. Improving aesthetic appearance and quality of life are defined as the primary aims of scoliosis treatment by health professionals. Studies that assess and compare the different treatment results in the field of quality of life and cosmethics are some what limited. A cross-sectional study was designed to compare quality of life and deformity perception in patients with adolescent idiopathic scoliosis (AIS) received conservative (exercise or exercise + brace) or surgical treatment. A total of 68 (58 females) patients aged 10-18 years with AIS received conservative (exercise or exercise+brace) or surgical treatment were invited to participate in the study. Quality of life (Scoliosis Research Society-23 (SRS-23)) and perception of deformity (Walter Reed Visual Assessment (WRVAS)) were assessed. Conservatively treated patients had significantly superior scores in function domain of SRS-23 than surgically treated patients (exercise/surgery, exercise+brace/surgery; p= 0.009, 0.004). Otherwise, surgically treated patients had significantly superior scores in self-image (p= 0.000, 0.000), and satisfaction with management (p= 0.001, 0.006) domains of SRS-23, and WRVAS (p= 0.000, 0.000) than conservative groups. In addition to radiographic assessments, quality of life, aesthetic perception, functionality, satisfaction with management, psycho-social status should carefully be taken into consideration by health professionals in the teratment of AIS.

  1. Restoration of vision in blind individuals using bionic devices: a review with a focus on cortical visual prostheses.

    PubMed

    Lewis, Philip M; Ackland, Helen M; Lowery, Arthur J; Rosenfeld, Jeffrey V

    2015-01-21

    The field of neurobionics offers hope to patients with sensory and motor impairment. Blindness is a common cause of major sensory loss, with an estimated 39 million people worldwide suffering from total blindness in 2010. Potential treatment options include bionic devices employing electrical stimulation of the visual pathways. Retinal stimulation can restore limited visual perception to patients with retinitis pigmentosa, however loss of retinal ganglion cells precludes this approach. The optic nerve, lateral geniculate nucleus and visual cortex provide alternative stimulation targets, with several research groups actively pursuing a cortically-based device capable of driving several hundred stimulating electrodes. While great progress has been made since the earliest works of Brindley and Dobelle in the 1960s and 1970s, significant clinical, surgical, psychophysical, neurophysiological, and engineering challenges remain to be overcome before a commercially-available cortical implant will be realized. Selection of candidate implant recipients will require assessment of their general, psychological and mental health, and likely responses to visual cortex stimulation. Implant functionality, longevity and safety may be enhanced by careful electrode insertion, optimization of electrical stimulation parameters and modification of immune responses to minimize or prevent the host response to the implanted electrodes. Psychophysical assessment will include mapping the positions of potentially several hundred phosphenes, which may require repetition if electrode performance deteriorates over time. Therefore, techniques for rapid psychophysical assessment are required, as are methods for objectively assessing the quality of life improvements obtained from the implant. These measures must take into account individual differences in image processing, phosphene distribution and rehabilitation programs that may be required to optimize implant functionality. In this review, we detail these and other challenges facing developers of cortical visual prostheses in addition to briefly outlining the epidemiology of blindness, and the history of cortical electrical stimulation in the context of visual prosthetics. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Aesthetics by Numbers: Links between Perceived Texture Qualities and Computed Visual Texture Properties

    PubMed Central

    Jacobs, Richard H. A. H.; Haak, Koen V.; Thumfart, Stefan; Renken, Remco; Henson, Brian; Cornelissen, Frans W.

    2016-01-01

    Our world is filled with texture. For the human visual system, this is an important source of information for assessing environmental and material properties. Indeed—and presumably for this reason—the human visual system has regions dedicated to processing textures. Despite their abundance and apparent relevance, only recently the relationships between texture features and high-level judgments have captured the interest of mainstream science, despite long-standing indications for such relationships. In this study, we explore such relationships, as these might be used to predict perceived texture qualities. This is relevant, not only from a psychological/neuroscience perspective, but also for more applied fields such as design, architecture, and the visual arts. In two separate experiments, observers judged various qualities of visual textures such as beauty, roughness, naturalness, elegance, and complexity. Based on factor analysis, we find that in both experiments, ~75% of the variability in the judgments could be explained by a two-dimensional space, with axes that are closely aligned to the beauty and roughness judgments. That a two-dimensional judgment space suffices to capture most of the variability in the perceived texture qualities suggests that observers use a relatively limited set of internal scales on which to base various judgments, including aesthetic ones. Finally, for both of these judgments, we determined the relationship with a large number of texture features computed for each of the texture stimuli. We find that the presence of lower spatial frequencies, oblique orientations, higher intensity variation, higher saturation, and redness correlates with higher beauty ratings. Features that captured image intensity and uniformity correlated with roughness ratings. Therefore, a number of computational texture features are predictive of these judgments. This suggests that perceived texture qualities—including the aesthetic appreciation—are sufficiently universal to be predicted—with reasonable accuracy—based on the computed feature content of the textures. PMID:27493628

  3. Reduced health-related quality of life among Japanese college students with visual impairment.

    PubMed

    Masaki, Iguchi

    2015-01-01

    Although previous studies have shown detrimental effects of visual impairment on health-related quality of life (HRQOL), they were primarily conducted on elderly individuals with visual impairment. The objective of this cross-sectional study was to investigate if HRQOL is impaired in young college students with visual impairment and to explore the relationships between HRQOL and other factors. It was hypothesized that visual impairment is not influential enough to lower the HRQOL of young people due to their better physical fitness and more flexible mentality. A total of 21 college students (mean age = 25 years old) with varying degrees of visual impairment completed the short form (SF)-36 health survey and questionnaires on daily physical activities. Subjects were grouped depending on the type of visual impairment: blind (n = 11) or severely impaired (n = 10). In addition, grip strength and single-leg standing balance were assessed. No between-group differences were found in the SF-36 scores. However, compared to the general Japanese standards (50.0 ± 10.0), the Vitality scores of the blind group were lower (41.9 ± 7.2, p = 0.004) and the Physical Function scores of the severely impaired group were higher (55.3 ± 2.4, p = 0.001). In addition, a negative correlation was found between standing balance (variability of foot center of pressure) and the Physical Component Summary score of the SF-36 (r(2) = 0.35, p = 0.005). These findings suggest that even among young people severe visual impairment leads to reductions in some components of HRQOL.

  4. Toward a perceptual video-quality metric

    NASA Astrophysics Data System (ADS)

    Watson, Andrew B.

    1998-07-01

    The advent of widespread distribution of digital video creates a need for automated methods for evaluating the visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics, and the economic need to reduce bit-rate to the lowest level that yields acceptable quality. In previous work, we have developed visual quality metrics for evaluating, controlling,a nd optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. Here I describe a new video quality metric that is an extension of these still image metrics into the time domain. Like the still image metrics, it is based on the Discrete Cosine Transform. An effort has been made to minimize the amount of memory and computation required by the metric, in order that might be applied in the widest range of applications. To calibrate the basic sensitivity of this metric to spatial and temporal signals we have made measurements of visual thresholds for temporally varying samples of DCT quantization noise.

  5. Galaxy HiCExplorer: a web server for reproducible Hi-C data analysis, quality control and visualization.

    PubMed

    Wolff, Joachim; Bhardwaj, Vivek; Nothjunge, Stephan; Richard, Gautier; Renschler, Gina; Gilsbach, Ralf; Manke, Thomas; Backofen, Rolf; Ramírez, Fidel; Grüning, Björn A

    2018-06-13

    Galaxy HiCExplorer is a web server that facilitates the study of the 3D conformation of chromatin by allowing Hi-C data processing, analysis and visualization. With the Galaxy HiCExplorer web server, users with little bioinformatic background can perform every step of the analysis in one workflow: mapping of the raw sequence data, creation of Hi-C contact matrices, quality assessment, correction of contact matrices and identification of topological associated domains (TADs) and A/B compartments. Users can create publication ready plots of the contact matrix, A/B compartments, and TADs on a selected genomic locus, along with additional information like gene tracks or ChIP-seq signals. Galaxy HiCExplorer is freely usable at: https://hicexplorer.usegalaxy.eu and is available as a Docker container: https://github.com/deeptools/docker-galaxy-hicexplorer.

  6. Effectiveness, safety, and effect on quality of life of topical salicylic acid peels for treatment of postinflammatory hyperpigmentation in dark skin.

    PubMed

    Joshi, Smita S; Boone, Susan L; Alam, Murad; Yoo, Simon; White, Lucile; Rademaker, Alfred; Helenowski, Irene; West, Dennis P; Kundu, Roopal V

    2009-04-01

    There are no randomized split-face model studies investigating treatments for postinflammatory hyperpigmentation (PIH) in dark skin. To assess the efficacy, safety, and effect on quality of life of salicylic acid peels for PIH in dark skin. Ten subjects with Fitzpatrick skin phototypes IV to VI were randomized to receive two 20% salicylic acid peels followed by three 30% salicylic acid peels to half of the face. The contralateral half remained untreated. Response was evaluated by photography reviewed by three blinded dermatologists. The Visual Analog Scale, Dermatology Life Quality Index (DLQI), and treatment quality questionnaire were administered. Improvement of PIH on the treatment side according to each rater (p=.81, p=.81, p=.42) and according to the raters combined (p=.11) approached but did not reach statistical significance. Subjects' Visual Analog Scale scores indicated significantly greater improvement of PIH on the treatment side than in the control (p=.004). Quality of life measured according to the DLQI improved after treatment but not statistically significantly so (p=.13). Treatment had no significant adverse effects. Salicylic acid peels are safe in this population. Although patients rated them as clinically effective, blinded raters found a brief series of peels to have less efficacy. Measured quality of life improved nominally.

  7. Visuo-spatial ability in colonoscopy simulator training.

    PubMed

    Luursema, Jan-Maarten; Buzink, Sonja N; Verwey, Willem B; Jakimowicz, J J

    2010-12-01

    Visuo-spatial ability is associated with a quality of performance in a variety of surgical and medical skills. However, visuo-spatial ability is typically assessed using Visualization tests only, which led to an incomplete understanding of the involvement of visuo-spatial ability in these skills. To remedy this situation, the current study investigated the role of a broad range of visuo-spatial factors in colonoscopy simulator training. Fifteen medical trainees (no clinical experience in colonoscopy) participated in two psycho-metric test sessions to assess four visuo-spatial ability factors. Next, participants trained flexible endoscope manipulation, and navigation to the cecum on the GI Mentor II simulator, for four sessions within 1 week. Visualization, and to a lesser degree Spatial relations were the only visuo-spatial ability factors to correlate with colonoscopy simulator performance. Visualization additionally covaried with learning rate for time on task on both simulator tasks. High Visualization ability indicated faster exercise completion. Similar to other endoscopic procedures, performance in colonoscopy is positively associated with Visualization, a visuo-spatial ability factor characterized by the ability to mentally manipulate complex visuo-spatial stimuli. The complexity of the visuo-spatial mental transformations required to successfully perform colonoscopy is likely responsible for the challenging nature of this technique, and should inform training- and assessment design. Long term training studies, as well as studies investigating the nature of visuo-spatial complexity in this domain are needed to better understand the role of visuo-spatial ability in colonoscopy, and other endoscopic techniques.

  8. Image gathering and restoration - Information and visual quality

    NASA Technical Reports Server (NTRS)

    Mccormick, Judith A.; Alter-Gartenberg, Rachel; Huck, Friedrich O.

    1989-01-01

    A method is investigated for optimizing the end-to-end performance of image gathering and restoration for visual quality. To achieve this objective, one must inevitably confront the problems that the visual quality of restored images depends on perceptual rather than mathematical considerations and that these considerations vary with the target, the application, and the observer. The method adopted in this paper is to optimize image gathering informationally and to restore images interactively to obtain the visually preferred trade-off among fidelity resolution, sharpness, and clarity. The results demonstrate that this method leads to significant improvements in the visual quality obtained by the traditional digital processing methods. These traditional methods allow a significant loss of visual quality to occur because they treat the design of the image-gathering system and the formulation of the image-restoration algorithm as two separate tasks and fail to account for the transformations between the continuous and the discrete representations in image gathering and reconstruction.

  9. Quality Services for Blind and Visually Handicapped Learners. Statements of Position.

    ERIC Educational Resources Information Center

    Scholl, Geraldine T., Ed.

    Seventeen position papers address essential elements in quality programing for visually handicapped learners. The papers represent the philosophy of the Council for Exceptional Children's Division for the Visually Handicapped. Following two foundation position papers, "Services for the Blind and Visually Impaired" (K. Huebner) and "Visually…

  10. The Chinese American Eye Study: Design and Methods

    PubMed Central

    Varma, Rohit; Hsu, Chunyi; Wang, Dandan; Torres, Mina; Azen, Stanley P.

    2016-01-01

    Purpose To summarize the study design, operational strategies and procedures of the Chinese American Eye Study (CHES), a population-based assessment of the prevalence of visual impairment, ocular disease, and visual functioning in Chinese Americans. Methods This population-based, cross-sectional study, included 4,570 Chinese, 50 years and older, residing in the city of Monterey Park, California. Each eligible participant completed a detailed interview and eye examination. The interview included an assessment of demographic, behavioral, and ocular risk factors and health-related and vision-related quality of life. The eye examination included measurements of visual acuity, intraocular pressure, visual fields, fundus and optic disc photography, a detailed anterior and posterior segment examination, and measurements of blood pressure, glycosylated hemoglobin levels, and blood glucose levels. Results The objectives of the CHES are to obtain prevalence estimates of visual impairment, refractive error, diabetic retinopathy, open-angle and angle-closure glaucoma, lens opacities, and age-related macular degeneration in Chinese-Americans. In addition, outcomes include effect estimates for risk factors associated with eye diseases. Lastly, CHES will investigate the genetic determinates of myopia and glaucoma. Conclusion The CHES will provide information about the prevalence and risk factors of ocular diseases in one of the fastest growing minority groups in the United States. PMID:24044409

  11. A Novel and Intelligent Home Monitoring System for Care Support of Elders with Cognitive Impairment.

    PubMed

    Lazarou, Ioulietta; Karakostas, Anastasios; Stavropoulos, Thanos G; Tsompanidis, Theodoros; Meditskos, Georgios; Kompatsiaris, Ioannis; Tsolaki, Magda

    2016-10-18

    Assistive technology, in the form of a smart home environment, is employed to support people with dementia. To propose a system for continuous and objective remote monitoring of problematic daily living activity areas and design personalized interventions based on system feedback and clinical observations for improving cognitive function and health-related quality of life. The assistive technology of the proposed system, including wearable, sleep, object motion, presence, and utility usage sensors, was methodically deployed at four different home installations of people with cognitive impairment. Detection of sleep patterns, physical activity, and activities of daily living, based on the collected sensor data and analytics, was available at all times through comprehensive data visualization solutions. Combined with clinical observation, targeted psychosocial interventions were introduced to enhance the participants' quality of life and improve their cognitive functions and daily functionality. Meanwhile, participants and their caregivers were able to visualize a reduced set of information tailored to their needs. Overall, paired-sample t-test analysis of monitored qualities revealed improvement for all participants in neuropsychological assessment. Moreover, improvement was detected from the beginning to the end of the trial, in physical condition and in the domains of sleep. Detecting abnormalities via the system, for example in sleep quality, such as REM sleep, has proved to be critical to assess current status, drive interventions, and evaluate improvements in a reliable manner. It has been proved that the proposed system is suitable to support clinicians to reliably drive and evaluate clinical interventions toward quality of life improvement of people with cognitive impairment.

  12. Influence of reconstruction algorithms on image quality in SPECT myocardial perfusion imaging.

    PubMed

    Davidsson, Anette; Olsson, Eva; Engvall, Jan; Gustafsson, Agnetha

    2017-11-01

    We investigated if image- and diagnostic quality in SPECT MPI could be maintained despite a reduced acquisition time adding Depth Dependent Resolution Recovery (DDRR) for image reconstruction. Images were compared with filtered back projection (FBP) and iterative reconstruction using Ordered Subsets Expectation Maximization with (IRAC) and without (IRNC) attenuation correction (AC). Stress- and rest imaging for 15 min was performed on 21 subjects with a dual head gamma camera (Infinia Hawkeye; GE Healthcare), ECG-gating with 8 frames/cardiac cycle and a low-dose CT-scan. A 9 min acquisition was generated using five instead of eight gated frames and was reconstructed with DDRR, with (IRACRR) and without AC (IRNCRR) as well as with FBP. Three experienced nuclear medicine specialists visually assessed anonymized images according to eight criteria on a four point scale, three related to image quality and five to diagnostic confidence. Statistical analysis was performed using Visual Grading Regression (VGR). Observer confidence in statements on image quality was highest for the images that were reconstructed using DDRR (P<0·01 compared to FBP). Iterative reconstruction without DDRR was not superior to FBP. Interobserver variability was significant for statements on image quality (P<0·05) but lower in the diagnostic statements on ischemia and scar. The confidence in assessing ischemia and scar was not different between the reconstruction techniques (P = n.s.). SPECT MPI collected in 9 min, reconstructed with DDRR and AC, produced better image quality than the standard procedure. The observers expressed the highest diagnostic confidence in the DDRR reconstruction. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  13. Effectiveness of mirror therapy, motor imagery, and virtual feedback on phantom limb pain following amputation: A systematic review.

    PubMed

    Herrador Colmenero, Laura; Perez Marmol, Jose Manuel; Martí-García, Celia; Querol Zaldivar, María de Los Ángeles; Tapia Haro, Rosa María; Castro Sánchez, Adelaida María; Aguilar-Ferrándiz, María Encarnación

    2018-06-01

    Phantom limb pain is reported in 50%-85% of people with amputation. Clinical interventions in treating central pain, such as mirror therapy, motor imagery, or virtual visual feedback, could redound in benefits to amputee patients with phantom limb pain. To provide an overview of the effectiveness of different techniques for treating phantom limb pain in amputee patients. Systematic review. A computerized literature search up to April 2017 was performed using the following databases: PubMed, Scopus, CINAHL, MEDLINE, ProQuest, PEDro, EBSCOhost, and Cochrane Plus. Methodological quality and internal validity score of each study were assessed using PEDro scale. For data synthesis, qualitative methods from the Cochrane Back Review Group were applied. In all, 12 studies met our inclusion criteria, where 9 were rated as low methodological quality and 3 rated moderate quality. All studies showed a significant reduction in pain, but there was heterogeneity among subjects and methodologies and any high-quality clinical trial (PEDro score ≤8; internal validity score ≤5) was not found. Mirror therapy, motor imaginary, and virtual visual feedback reduce phantom limb pain; however, there is limited scientific evidence supporting their effectiveness. Future studies should include designs with more solid research methods, exploring short- and long-term benefits of these therapies. Clinical relevance This systematic review investigates the effectiveness of mirror therapy, motor imagery, and virtual visual feedback on phantom limb pain, summarizing the currently published trials and evaluating the research quality. Although these interventions have positive benefits in phantom limb pain, there is still a lack of evidence for supporting their effectiveness.

  14. Changes in visual quality, physiological and biochemical parameters assessed during the postharvest storage at chilling or non-chilling temperatures of three sweet basil (Ocimum basilicum L.) cultivars.

    PubMed

    Fratianni, Florinda; Cefola, Maria; Pace, Bernardo; Cozzolino, Rosaria; De Giulio, Beatrice; Cozzolino, Autilia; d'Acierno, Antonio; Coppola, Raffaele; Logrieco, Antonio Francesco; Nazzaro, Filomena

    2017-08-15

    Leaves of three different sweet basil (Ocimum basilicum L.) cultivars (Italico a foglia larga, Cammeo, and Italiano classico) packed in macro-perforated polyethylene bags were stored at chilling (4°C) or non-chilling temperature (12°C) for 9days. During storage, visual quality, physiological (respiration rate, ethylene production, ammonium content) and chemical (antioxidant activity, total polyphenols and polyphenol profile) parameters were measured. Detached leaves stored at chilling temperature showed visual symptoms related to chilling injury, while ethylene production and ammonium content resulted associated to cultivar sensibility to damage at low temperature. Storage at 4°C caused a depletion in polyphenols content and antioxidant capability, which was preserved at 12°C. Regarding the polyphenols profile, stressful storage conditions did not enhance the phenolic metabolism. However, leaves stored at 12°C did not loss a significant amount of metabolites respect to fresh leaves, suggesting the possibility to extend the storability after the expiration date, for a possible recovery of bioactive compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Change in Quality of Life after Rehabilitation: Prognostic Factors for Visually Impaired Adults

    ERIC Educational Resources Information Center

    Langelaan, Maaike; de Boer, Michiel R.; van Nispen, Ruth M. A.; Wouters, Bill; Moll, Annette C.; van Rens, Ger H. M. B.

    2009-01-01

    The overall aim of rehabilitation for visually impaired adults is to improve the quality of life and (societal) participation. The objectives of this study were to obtain the short-term and long-term outcome of a comprehensive rehabilitation programme on quality of life for visually impaired adults, and prognostic baseline factors responsible for…

  16. Overcoming Presbyopia by Manipulating the Eyes' Optics

    NASA Astrophysics Data System (ADS)

    Zheleznyak, Leonard A.

    Presbyopia, the age-related loss of accommodation, is a visual condition affecting all adults over the age of 45 years. In presbyopia, individuals lose the ability to focus on nearby objects, due to a lifelong growth and stiffening of the eye's crystalline lens. This leads to poor near visual performance and affects patients' quality of life. The objective of this thesis is aimed towards the correction of presbyopia and can be divided into four aims. First, we examined the characteristics and limitations of currently available strategies for the correction of presbyopia. A natural-view wavefront sensor was used to objectively measure the accommodative ability of patients implanted with an accommodative intraocular lens (IOL). Although these patients had little accommodative ability based on changes in power, pupil miosis and higher order aberrations led to an improvement in through-focus retinal image quality in some cases. To quantify the through-focus retinal image quality of accommodative and multifocal IOLs directly, an adaptive optics (AO) IOL metrology system was developed. Using this system, the impact of corneal aberrations in regard to presbyopia-correcting IOLs was assessed, providing an objective measure of through-focus retinal image quality and practical guidelines for patient selection. To improve upon existing multifocal designs, we investigated retinal image quality metrics for the prediction of through-focus visual performance. The preferred metric was based on the fidelity of an image convolved with an aberrated point spread function. Using this metric, we investigated the potential of higher order aberrations and pupil amplitude apodization to increase the depth of focus of the presbyopic eye. Thirdly, we investigated modified monovision, a novel binocular approach to presbyopia correction using a binocular AO vision simulator. In modified monovision, different magnitudes of defocus and spherical aberration are introduced to each eye, thereby taking advantage of the binocular visual system. Several experiments using the binocular AO vision simulator found modified monovision led to significant improvements in through-focus visual performance, binocular summation and stereoacuity, as compared to traditional monovision. Finally, we addressed neural factors, affecting visual performance in modified monovision, such as ocular dominance and neural plasticity. We found that pairing modified monovision with a vision training regimen may further improve visual performance beyond the limits set by optics via neural plasticity. This opens the door to an exciting new avenue of vision correction to accompany optical interventions. The research presented in this thesis offers important guidelines for the clinical and scientific communities. Furthermore, the techniques described herein may be applied to other fields of ophthalmology, such as childhood myopia progression.

  17. The effect of spinal curvature on the photogrammetric assessment on static balance in elderly women.

    PubMed

    Drzał-Grabiec, Justyna; Rachwał, Maciej; Podgórska-Bednarz, Justyna; Rykała, Justyna; Snela, Sławomir; Truszczyńska, Aleksandra; Trzaskoma, Zbigniew

    2014-05-29

    Involutional changes to the body in elderly patients affect the shape of the spine and the activity of postural muscles. The purpose of this study was to assess the influence of age-related changes in spinal curvature on postural balance in elderly women. The study population consisted of 90 women, with a mean age of 70 ± 8.01 years. Static balance assessments were conducted on a tensometric platform, and posturographic assessments of body posture were performed using a photogrammetric method based on the Projection Moiré method. The results obtained were analysed using the Spearman's rank correlation coefficient test. We found a statistically significant correlation between body posture and the quality of the balance system response based on the corrective function of the visual system. The shape of the spinal curvature influenced postural stability, as measured by static posturography. Improvement in the quality of the balance system response depended on corrective information from the visual system and proprioceptive information from the paraspinal muscles. The sensitivity of the balance system to the change of centre of pressure location was influenced by the direction of the change in rotation of the shoulder girdle and spine. Development of spinal curvature in the sagittal plane and maintenance of symmetry in the coronal and transverse planes are essential for correct balance control, which in turn is essential for the development of a properly proportioned locomotor system.

  18. Vision related quality of life in spinocerebellar ataxia.

    PubMed

    Kedar, Sachin; Ghate, Deepta; Murray, Earnest L; Corbett, James J; Subramony, S H

    2015-11-15

    Spinocerebellar ataxia (SCA) leads to abnormal ocular motility and alignment. The objective of this study was to quantitatively assess vision, ocular motility and alignment and its impact on vision related quality of life (VRQOL) in SCA. Nineteen genetically diagnosed SCA subjects (11 SCA type 3, 3 SCA type 1 and 5 SCA type 6) participated at two university centers. All subjects completed the National Eye Institute Visual Function Questionnaire (NEI-VFQ), 10-Item Neuro-Ophthalmic Supplement (NOS), scale for assessment and rating of ataxia (SARA) and ophthalmic examination. Twelve subjects seen at one of the 2 sites underwent quantitative ocular motility and alignment assessment. Composite scores for NEI-VFQ (mean 76.3±13) and NOS (mean 65.2±16.8) were significantly decreased in SCA subjects. NEI-VFQ subscale scores were decreased for general, near, distance and peripheral vision and driving. SCA patients had decreased low contrast sensitivity, stereoacuity and multiple ocular motility defects which included gaze limitation (9/12), nystagmus (5/12), distance esophoria (11/12), near exophoria (12/12) and receded near point of convergence. A significant negative correlation was noted between composite scores and distance convergence fusional amplitude. VRQOL is significantly decreased in SCA compared to normal population. All SCA patients should be screened for visual disability and referred for neuro-ophthalmic assessment promptly. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. GAGES: A stream gage database for evaluating natural and alteredflow conditions in the conterminous United States

    USGS Publications Warehouse

    Falcone, James A.; Carlisle, Daren M.; Wolock, David M.; Meador, Michael R.

    2010-01-01

    In addition, watersheds were assessed for their reference quality within nine broad regions for use in studies intended to characterize stream flows under conditions minimally influenced by human activities. Three primary criteria were used to assess reference quality: (1) a quantitative index of anthropogenic modification within the watershed based on GIS-derived variables, (2) visual inspection of every stream gage and drainage basin from recent high-resolution imagery and topographic maps, and (3) information about man-made influences from USGS Annual Water Data Reports. From the set of 6785 sites, we identified 1512 as reference-quality stream gages. All data derived for these watersheds as well as the reference condition evaluation are provided as an online data set termed GAGES (geospatial attributes of gages for evaluating stream flow).

  20. Eye of the Beholder: Stage Entrance Behavior and Facial Expression Affect Continuous Quality Ratings in Music Performance

    PubMed Central

    Waddell, George; Williamon, Aaron

    2017-01-01

    Judgments of music performance quality are commonly employed in music practice, education, and research. However, previous studies have demonstrated the limited reliability of such judgments, and there is now evidence that extraneous visual, social, and other “non-musical” features can unduly influence them. The present study employed continuous measurement techniques to examine how the process of forming a music quality judgment is affected by the manipulation of temporally specific visual cues. Video footage comprising an appropriate stage entrance and error-free performance served as the standard condition (Video 1). This footage was manipulated to provide four additional conditions, each identical save for a single variation: an inappropriate stage entrance (Video 2); the presence of an aural performance error midway through the piece (Video 3); the same error accompanied by a negative facial reaction by the performer (Video 4); the facial reaction with no corresponding aural error (Video 5). The participants were 53 musicians and 52 non-musicians (N = 105) who individually assessed the performance quality of one of the five randomly assigned videos via a digital continuous measurement interface and headphones. The results showed that participants viewing the “inappropriate” stage entrance made judgments significantly more quickly than those viewing the “appropriate” entrance, and while the poor entrance caused significantly lower initial scores among those with musical training, the effect did not persist long into the performance. The aural error caused an immediate drop in quality judgments that persisted to a lower final score only when accompanied by the frustrated facial expression from the pianist; the performance error alone caused a temporary drop only in the musicians' ratings, and the negative facial reaction alone caused no reaction regardless of participants' musical experience. These findings demonstrate the importance of visual information in forming evaluative and aesthetic judgments in musical contexts and highlight how visual cues dynamically influence those judgments over time. PMID:28487662

  1. Applying the metro map to software development management

    NASA Astrophysics Data System (ADS)

    Aguirregoitia, Amaia; Dolado, J. Javier; Presedo, Concepción

    2010-01-01

    This paper presents MetroMap, a new graphical representation model for controlling and managing the software development process. Metromap uses metaphors and visual representation techniques to explore several key indicators in order to support problem detection and resolution. The resulting visualization addresses diverse management tasks, such as tracking of deviations from the plan, analysis of patterns of failure detection and correction, overall assessment of change management policies, and estimation of product quality. The proposed visualization uses a metaphor with a metro map along with various interactive techniques to represent information concerning the software development process and to deal efficiently with multivariate visual queries. Finally, the paper shows the implementation of the tool in JavaFX with data of a real project and the results of testing the tool with the aforementioned data and users attempting several information retrieval tasks. The conclusion shows the results of analyzing user response time and efficiency using the MetroMap visualization system. The utility of the tool was positively evaluated.

  2. Measuring the Quality of Life of Visually Impaired Children: First Stage Psychometric Evaluation of the Novel VQoL_CYP Instrument.

    PubMed

    Tadić, Valerija; Cooper, Andrew; Cumberland, Phillippa; Lewando-Hundt, Gillian; Rahi, Jugnoo S

    2016-01-01

    To report piloting and initial validation of the VQoL_CYP, a novel age-appropriate vision-related quality of life (VQoL) instrument for self-reporting by children with visual impairment (VI). Participants were a random patient sample of children with VI aged 10-15 years. 69 patients, drawn from patient databases at Great Ormond Street Hospital and Moorfields Eye Hospital, United Kingdom, participated in piloting of the draft 47-item VQoL instrument, which enabled preliminary item reduction. Subsequent administration of the instrument, alongside functional vision (FV) and generic health-related quality of life (HRQoL) self-report measures, to 101 children with VI comprising a nationally representative sample enabled further item reduction and evaluation of psychometric properties using Rasch analysis. Construct validity was assessed through Pearson correlation coefficients. Item reduction through piloting (8 items removed for skewness and individual item response pattern) and validation (1 item removed for skewness and 3 for misfit in Rasch) produced a 35-item scale, with fit values within acceptable limits, no notable differential item functioning, good measurement precision, ordered response categories and acceptable targeting in Rasch. The VQoL_CYP showed good construct validity, correlating strongly with HRQoL scores, moderately with FV scores but not with acuity. Robust child-appropriate self-report VQoL measures for children with VI are necessary for understanding the broader impacts of living with a visual disability, distinguishing these from limited functioning per se. Future planned use in larger patient samples will allow further psychometric development of the VQoL_CYP as an adjunct to objective outcomes assessment.

  3. Clinical Rating of Movement-Pattern Quality in Patients With Femoroacetabular Impingement Syndrome: A Methodological Study.

    PubMed

    Casartelli, Nicola C; Maffiuletti, Nicola A; Brunner, Romana; Büchi, Marcel; Sutter, Reto; Pfirrmann, Christian W; Naal, Florian D; Leunig, Michael; Bizzini, Mario

    2018-04-01

    Study Design Cross-sectional study. Objectives To evaluate intrarater and interrater agreement among physical therapists with different clinical experience in performing a visual rating of movement-pattern quality of patients with femoroacetabular impingement (FAI) syndrome using a semi-quantitative scale. Background Visual rating of movement patterns in patients with FAI syndrome is of interest, because poor control of dynamic hip motion is frequently noted. Methods A video camera was used to record the performance of 34 patients with FAI syndrome performing single-limb standing, squat, frontal lunge, hop lunge, bridge, and plank. Visual rating of movement, as recorded on video, was performed by a highly experienced, a moderately experienced, and a novice physical therapist on 2 occasions using a semi-quantitative scale. Hip abductor strength was assessed using dynamometry, and hip pain and function were assessed with a patient-reported questionnaire. Intrarater and interrater agreement among physical therapists was evaluated using Gwet's agreement coefficient 1. Construct validity was evaluated as the association between physical therapists' rating and patients' hip abductor strength, pain, and function. Results Good intrarater and interrater agreement was observed in the highly experienced and moderately experienced physical therapists when rating single-limb standing, bridge, and plank. Poor to moderate intrarater and interrater agreement was found when they rated squat, frontal lunge, and hop lunge. Poor performers, as rated by the highly experienced physical therapist only, demonstrated lower hip abductor strength (P<.05), and similar hip pain and hip function compared to those of good performers. Conclusion Movement-pattern quality of patients with FAI syndrome should be rated by a highly experienced physical therapist. J Orthop Sports Phys Ther 2018;48(4):260-269. doi:10.2519/jospt.2018.7840.

  4. Measuring visual outcomes in children with uveitis using the “Effects of Youngsters’ Eyesight on Quality of Life” questionnaire

    PubMed Central

    Angeles-Han, Sheila T.; Yeh, Steven; McCracken, Courtney; Jenkins, Kirsten; Stryker, Daneka; Myoung, Erica; Vogler, Larry; Rouster-Stevens, Kelly; Lambert, Scott R.; Harrison, Melanie J.; Prahalad, Sampath; Drews-Botsch, Carolyn

    2015-01-01

    Objective The Effects of Youngsters’ Eyesight on Quality of Life (EYE-Q) is a novel measure of vision-related quality of life (QOL) and function in children. We aim to determine the validity of EYE-Q in childhood uveitis. Methods We abstracted medical record data on arthritis and uveitis in a convenience sample of children with juvenile idiopathic arthritis (JIA) and/or uveitis. In addition to the EYE-Q, parents and patients completed questionnaires on overall QOL (Pediatric QOL Inventory - PedsQL), and physical functioning (Childhood Health Assessment Questionnaire - CHAQ). Results Among 57 children (8 JIA, 24 JIA and uveitis, 25 uveitis alone), 102 ocular examinations were performed within 1 month of completing questionnaires. Uveitis patients had bilateral disease (69%), anterior involvement (78%), synechiae (51%) and cataracts (49%). Children with vision loss in their better eye (visual acuity (VA) 20/50 or worse) had worse EYE-Q (p = 0.006), and PedsQL (p = 0.028), but not CHAQ scores. The EYE-Q moderately correlated with logMAR VA (rs = −0.43), PedsQL (rs = 0.43) and CHAQ (rs = −0.45), but was not correlated with anterior chamber cells or intraocular pressure. The PedsQL and CHAQ did not correlate with VA or cells. There were strong correlations between the parent and child EYE-Q (rs = 0.62). Cronbach's α for the child report was 0.91. The EYE-Q had strong test-retest reliability (rs=0.75). Conclusion The EYE-Q may be an important tool in the assessment of visual outcomes in childhood uveitis and an improvement over general measures in detecting changes in vision-related function. PMID:26037544

  5. Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

    PubMed

    Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A

    2014-01-01

    Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  6. Newly-developed, forward-viewing echoendoscope: a comparative pilot study to the standard echoendoscope in the imaging of abdominal organs and feasibility of endoscopic ultrasound-guided interventions.

    PubMed

    Iwashita, Takuji; Nakai, Yousuke; Lee, John G; Park, Do Hyun; Muthusamy, V Raman; Chang, Kenneth J

    2012-02-01

    Multiple diagnostic and therapeutic endoscopic ultrasound (EUS) procedures have been widely performed using a standard oblique-viewing (OV) curvilinear array (CLA) echoendoscope. Recently, a new, forward-viewing (FV) CLA was developed, with the advantages of improved endoscopic viewing and manipulation of devices. However, the FV-CLA echoendoscope has a narrower ultrasound scanning field, and lacks an elevator, which might represent obstacles for clinical use. The aim of this study was to compare the FV-CLA echoendoscope to the OV-CLA echoendoscope for EUS imaging of abdominal organs, and to assess the feasibility of EUS-guided interventions using the FV-CLA echoendoscope. EUS examinations were first performed and recorded using the OV-CLA echoendoscope, followed immediately by the FV-CLA echoendoscope. Video recordings were then assessed by two independent endosonographers in a blinded fashion. The EUS visualization and image quality of specific abdominal organs/structures were scored. Any indicated fine-needle aspiration (FNA) or intervention was performed using the FV-CLA echoendoscope, with the OV-CLA echoendoscope as salvage upon failure. A total of 21 patients were examined in the study. Both echoendoscopes had similar visualization and image quality for all organs/structures, except the common hepatic duct (CHD), which was seen significantly better with the FV-CLA echoendoscope. EUS interventions were conducted in eight patients, including FNA of pancreatic mass (3), pancreatic cyst (3), and cystgastrostomy (2). The FV-CLA echoendoscope was successful in seven patients. One failed FNA of the pancreatic head cyst was salvaged using the OV-CLA echoendoscope. There were no differences between the FV-CLA echoendoscope and the OV-CLA echoendoscope in visualization or image quality on upper EUS, except for the superior image quality of CHD using the FV-CLA echoendoscope. Therefore, the disadvantages of the FV-CLA echoendoscope appear minimal in light of the potential advantages. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  7. Efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia.

    PubMed

    Fusco, Natália; Germano, Giseli Donadon; Capellini, Simone Aparecida

    2015-01-01

    To verify the efficacy of a perceptual and visual-motor skill intervention program for students with dyslexia. The participants were 20 students from third to fifth grade of a public elementary school in Marília, São Paulo, aged from 8 years to 11 years and 11 months, distributed into the following groups: Group I (GI; 10 students with developmental dyslexia) and Group II (GII; 10 students with good academic performance). A perceptual and visual-motor intervention program was applied, which comprised exercises for visual-motor coordination, visual discrimination, visual memory, visual-spatial relationship, shape constancy, sequential memory, visual figure-ground coordination, and visual closure. In pre- and post-testing situations, both groups were submitted to the Test of Visual-Perceptual Skills (TVPS-3), and the quality of handwriting was analyzed using the Dysgraphia Scale. The analyzed statistical results showed that both groups of students had dysgraphia in pretesting situation. In visual perceptual skills, GI presented a lower performance compared to GII, as well as in the quality of writing. After undergoing the intervention program, GI increased the average of correct answers in TVPS-3 and improved the quality of handwriting. The developed intervention program proved appropriate for being applied to students with dyslexia, and showed positive effects because it provided improved visual perception skills and quality of writing for students with developmental dyslexia.

  8. Scenario-visualization for the assessment of perceived green space qualities at the urban-rural fringe.

    PubMed

    Lange, Eckart; Hehl-Lange, Sigrid; Brewer, Mark J

    2008-11-01

    The provision of green space is increasingly being perceived as an important factor for quality of life. However, green spaces often face high developmental pressure. The main objective of this study is to investigate a prospective approach to green space planning by combining three-dimensional (3D) visualization of green space scenarios and survey techniques to facilitate improved participation of the public. Aside from the 'Status quo', scenarios 'Agriculture', 'Recreation', 'Nature conservation' and 'Wind turbines' are visualized in three dimensions. In order to test responses, a survey was conducted both in print format and on the Internet. Overall, 49 different visualizations that belong to one of the scenarios were available in the survey and were rated according to the perceived esthetic, recreational and ecological values. The highest rated scenes include vegetation elements such as meadows with orchards, single trees, shrubs or forest. The least attractive scenes are those where buildings are highly dominant or where there are no vegetation elements. Based on the ratings for the individual images and on the corresponding scenarios, our study shows that there is high potential for improving the existing landscape. All suggested changes are either rated about equal to or considerably higher than the status quo, with the scenario 'Nature conservation' receiving the highest scores.

  9. Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid

    PubMed Central

    Gorczynska, Iwona; Migacz, Justin V.; Zawadzki, Robert J.; Capps, Arlie G.; Werner, John S.

    2016-01-01

    We compared the performance of three OCT angiography (OCTA) methods: speckle variance, amplitude decorrelation and phase variance for imaging of the human retina and choroid. Two averaging methods, split spectrum and volume averaging, were compared to assess the quality of the OCTA vascular images. All data were acquired using a swept-source OCT system at 1040 nm central wavelength, operating at 100,000 A-scans/s. We performed a quantitative comparison using a contrast-to-noise (CNR) metric to assess the capability of the three methods to visualize the choriocapillaris layer. For evaluation of the static tissue noise suppression in OCTA images we proposed to calculate CNR between the photoreceptor/RPE complex and the choriocapillaris layer. Finally, we demonstrated that implementation of intensity-based OCT imaging and OCT angiography methods allows for visualization of retinal and choroidal vascular layers known from anatomic studies in retinal preparations. OCT projection imaging of data flattened to selected retinal layers was implemented to visualize retinal and choroidal vasculature. User guided vessel tracing was applied to segment the retinal vasculature. The results were visualized in a form of a skeletonized 3D model. PMID:27231598

  10. Missing depth cues in virtual reality limit performance and quality of three dimensional reaching movements

    PubMed Central

    Mayo, Johnathan; Baur, Kilian; Wittmann, Frieder; Riener, Robert; Wolf, Peter

    2018-01-01

    Background Goal-directed reaching for real-world objects by humans is enabled through visual depth cues. In virtual environments, the number and quality of available visual depth cues is limited, which may affect reaching performance and quality of reaching movements. Methods We assessed three-dimensional reaching movements in five experimental groups each with ten healthy volunteers. Three groups used a two-dimensional computer screen and two groups used a head-mounted display. The first screen group received the typically recreated visual depth cues, such as aerial and linear perspective, occlusion, shadows, and texture gradients. The second screen group received an abstract minimal rendering lacking those. The third screen group received the cues of the first screen group and absolute depth cues enabled by retinal image size of a known object, which realized with visual renderings of the handheld device and a ghost handheld at the target location. The two head-mounted display groups received the same virtually recreated visual depth cues as the second or the third screen group respectively. Additionally, they could rely on stereopsis and motion parallax due to head-movements. Results and conclusion All groups using the screen performed significantly worse than both groups using the head-mounted display in terms of completion time normalized by the straight-line distance to the target. Both groups using the head-mounted display achieved the optimal minimum in number of speed peaks and in hand path ratio, indicating that our subjects performed natural movements when using a head-mounted display. Virtually recreated visual depth cues had a minor impact on reaching performance. Only the screen group with rendered handhelds could outperform the other screen groups. Thus, if reaching performance in virtual environments is in the main scope of a study, we suggest applying a head-mounted display. Otherwise, when two-dimensional screens are used, achievable performance is likely limited by the reduced depth perception and not just by subjects’ motor skills. PMID:29293512

  11. [Experience of the implementation of the method of the integral assessment of drinking water on indicators of chemical harmlessness in St. Petersburg].

    PubMed

    Mel'tser, A V; Erastova, N V; Kiselev, A V

    2013-01-01

    Providing population with quality drinking water--one of the priority tasks of the state policy aimed at maintaining the health of citizens. Hygienic rating of the drinking water quality envisages requirements to assurance its safety in the epidemiological and radiation relations, harmlessness of chemical composition and good organoleptic properties. There are numerous data proving the relationship between the chemical composition of drinking water and human health, and therefore the issue of taking a hygienically sound measures to improve the efficiency of water treatment has more and more priority. High water quality--the result of complex solution of tasks, including an integral approach to assessment of the quality of drinking water the use of hygienically sound decisions in the modernization of water treatment systems. The results of the integral assessment of drinking water on the properties of harmlessness have shown its actuality in the development and implementation of management decisions. The use of the spatial characteristics of integrated indices permits to visualize changes in the quality of drinking water in all stages of production and transportation from the position of health risks, evaluate the effectiveness of technological solutions and set priorities for investing.

  12. LOD map--A visual interface for navigating multiresolution volume visualization.

    PubMed

    Wang, Chaoli; Shen, Han-Wei

    2006-01-01

    In multiresolution volume visualization, a visual representation of level-of-detail (LOD) quality is important for us to examine, compare, and validate different LOD selection algorithms. While traditional methods rely on ultimate images for quality measurement, we introduce the LOD map--an alternative representation of LOD quality and a visual interface for navigating multiresolution data exploration. Our measure for LOD quality is based on the formulation of entropy from information theory. The measure takes into account the distortion and contribution of multiresolution data blocks. A LOD map is generated through the mapping of key LOD ingredients to a treemap representation. The ordered treemap layout is used for relative stable update of the LOD map when the view or LOD changes. This visual interface not only indicates the quality of LODs in an intuitive way, but also provides immediate suggestions for possible LOD improvement through visually-striking features. It also allows us to compare different views and perform rendering budget control. A set of interactive techniques is proposed to make the LOD adjustment a simple and easy task. We demonstrate the effectiveness and efficiency of our approach on large scientific and medical data sets.

  13. Effect of a Smart Start Playground Improvement Grant on Child Care Playground Hazards. Smart Start Evaluation Report.

    ERIC Educational Resources Information Center

    Kotch, Jonathan; Guthrie, Christine

    Smart Start (North Carolina) playground improvement grants were awarded to cover playground safety assessment, planning and evaluation, quality enhancements (such as fencing, surfacing, and new equipment), and safety programs. Visual inspections were conducted of the safety of child care home and center playgrounds after Smart Start-sponsored…

  14. Linking log quality with product performance

    Treesearch

    D. W. Green; Robert Ross

    1997-01-01

    In the United States, log grading procedures use visual assessment of defects, in relation to the log scaling diameter, to estimate the yield of lumber that maybe expected from the log. This procedure was satisfactory when structural grades were based only on defect size and location. In recent years, however, structural products have increasingly been graded using a...

  15. 76 FR 54227 - Draft Toxicological Review of n-Butanol: In Support of Summary Information on the Integrated Risk...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... found in the environment. Through the IRIS Program, EPA provides the highest quality science-based human... for the external review draft human health assessment titled, ``Toxicological Review of n-Butanol: In... will need audio-visual equipment (e.g., laptop computer and slide projector). In general, each...

  16. Rating reliability and representation validity in scenic landscape assessments

    Treesearch

    James F. Palmer; Robin E. Hoffman

    2001-01-01

    The US Supreme Court recently determined that experts from all fields of knowledge must demonstrate the reliability and validity of their testimony. While the broader implications of their finding have yet to manifest itself, it clearly has the potential to challenge all manner of professional practices. This paper explores the reliability of visual quality ratings of...

  17. Quality assessment of remote sensing image fusion using feature-based fourth-order correlation coefficient

    NASA Astrophysics Data System (ADS)

    Ma, Dan; Liu, Jun; Chen, Kai; Li, Huali; Liu, Ping; Chen, Huijuan; Qian, Jing

    2016-04-01

    In remote sensing fusion, the spatial details of a panchromatic (PAN) image and the spectrum information of multispectral (MS) images will be transferred into fused images according to the characteristics of the human visual system. Thus, a remote sensing image fusion quality assessment called feature-based fourth-order correlation coefficient (FFOCC) is proposed. FFOCC is based on the feature-based coefficient concept. Spatial features related to spatial details of the PAN image and spectral features related to the spectrum information of MS images are first extracted from the fused image. Then, the fourth-order correlation coefficient between the spatial and spectral features is calculated and treated as the assessment result. FFOCC was then compared with existing widely used indices, such as Erreur Relative Globale Adimensionnelle de Synthese, and quality assessed with no reference. Results of the fusion and distortion experiments indicate that the FFOCC is consistent with subjective evaluation. FFOCC significantly outperforms the other indices in evaluating fusion images that are produced by different fusion methods and that are distorted in spatial and spectral features by blurring, adding noise, and changing intensity. All the findings indicate that the proposed method is an objective and effective quality assessment for remote sensing image fusion.

  18. [Objective assessment of the functional impact of dry eye severity on the quality of vision by double-pass aberrometry].

    PubMed

    Habay, T; Majzoub, S; Perrault, O; Rousseau, C; Pisella, P J

    2014-03-01

    To assess the functional impact of the severity of dry eye on the quality of vision by measuring an Objective Scatter Index (OSI) using double pass aberrometry. Twenty-eight patients (56 eyes) with dry eye syndromes of varying severity participated in this study. A double-pass aberrometer was used to measure the dynamic changes in the OSI for 20 seconds. The mean and standard deviations of the OSI and the number of blinks occurring during the examination were compared as a function of the clinical severity of dry eye disease. The mean OSI increased with the severity of dry eye syndrome with a significant difference for stages 3 (P<0.01) and 4 (P<0.001) compared to stages 1 and 2, without a significant difference based on age (P>0.8) or visual acuity (P>0.2). Standard deviation of the OSI also increased with the severity of dry eye disease, with a significant difference for stages 3 (P<0.01) and 4 (P<0.0001) compared to stages 1 and 2, with no significant increase in the number of blinks (P>0.2). The values of the OSI standard deviation represented the dynamic nature of aberrometric changes related to the instability of the tear film. Quality of vision of patients deteriorated in relation to the severity of their dry eye. The analysis of OSI standard deviation appears to be an objective way to assess the intensity of subjective visual disturbances reported by patients with dry eye syndrome. It also provides a new tool to assess the severity of damage to the ocular surface. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Experienced quality factors: qualitative evaluation approach to audiovisual quality

    NASA Astrophysics Data System (ADS)

    Jumisko-Pyykkö, Satu; Häkkinen, Jukka; Nyman, Göte

    2007-02-01

    Subjective evaluation is used to identify impairment factors of multimedia quality. The final quality is often formulated via quantitative experiments, but this approach has its constraints, as subject's quality interpretations, experiences and quality evaluation criteria are disregarded. To identify these quality evaluation factors, this study examined qualitatively the criteria participants used to evaluate audiovisual video quality. A semi-structured interview was conducted with 60 participants after a subjective audiovisual quality evaluation experiment. The assessment compared several, relatively low audio-video bitrate ratios with five different television contents on mobile device. In the analysis, methodological triangulation (grounded theory, Bayesian networks and correspondence analysis) was applied to approach the qualitative quality. The results showed that the most important evaluation criteria were the factors of visual quality, contents, factors of audio quality, usefulness - followability and audiovisual interaction. Several relations between the quality factors and the similarities between the contents were identified. As a research methodological recommendation, the focus on content and usage related factors need to be further examined to improve the quality evaluation experiments.

  20. [National survey of blindness and avoidable visual impairment in Argentina, 2013].

    PubMed

    Barrenechea, Rosario; de la Fuente, Inés; Plaza, Roberto Gustavo; Flores, Nadia; Segovia, Lía; Villagómez, Zaida; Camarero, Esteban Elián; Zepeda-Romero, Luz Consuelo; Lansingh, Van C; Limburg, Hans; Silva, Juan Carlos

    2015-01-01

    Determine the prevalence of blindness and avoidable visual impairment in Argentina, its causes, the coverage of cataract surgery, and the barriers that hinder access to these services. Cross-sectional population study conducted between May and November 2013 using the standard methodology for rapid assessment of avoidable blindness (RAAB), with a random cluster sampling of 50 people aged 50 years or more, -representative of the entire country. Participants' visual acuity (VA) was measured and the lens and posterior pole were examined by direct ophthalmoscopy. An assessment was made of the causes of having VA < 20/60, the coverage and quality of cataract surgery, and the barriers to accessing treatment. 3 770 people were assessed (92.0% of the projected number). The prevalence of blindness was 0.7% (confidence interval of 95%: 0.4-1.0%). Unoperated cataract was the main cause of blindness and severe visual impairment (44.0% and 71.1%, respectively), while the main cause of moderate visual impairment was uncorrected refractive errors (77.8%). Coverage of cataract surgery was of 97.1%, and 82.0% of operated eyes achieved VA ≥ 20/60. The main barriers to receiving this treatment were fear of the surgical procedure or of a poor result (34.9%), the cost (30.2%), and not having access to the treatment (16.3%). There is a low prevalence of blindness in the studied population and cataract is the main cause of blindness and severe visual impairment. Efforts should continue to extend coverage of cataract surgery, enhance preoperative evaluation, improve calculations of the intraocular lenses that patients need, and correct post-operative refractive errors with greater precision.

  1. [Method for the quality assessment of data collection processes in epidemiological studies].

    PubMed

    Schöne, G; Damerow, S; Hölling, H; Houben, R; Gabrys, L

    2017-10-01

    For a quantitative evaluation of primary data collection processes in epidemiological surveys based on accompaniments and observations (in the field), there is no description of test criteria and methodologies in relevant literature and thus no known application in practice. Therefore, methods need to be developed and existing procedures adapted. The aim was to identify quality-relevant developments within quality dimensions by means of inspection points (quality indicators) during the process of data collection. As a result we seek to implement and establish a methodology for the assessment of overall survey quality supplementary to standardized data analyses. Monitors detect deviations from standard primary data collection during site visits by applying standardized checklists. Quantitative results - overall and for each dimension - are obtained by numerical calculation of quality indicators. Score results are categorized and color coded. This visual prioritization indicates necessity for intervention. The results obtained give clues regarding the current quality of data collection. This allows for the identification of such sections where interventions for quality improvement are needed. In addition, process quality development can be shown over time on an intercomparable basis. This methodology for the evaluation of data collection quality can identify deviations from norms, focalize quality analyses and help trace causes for significant deviations.

  2. A Bayesian Nonparametric Approach to Image Super-Resolution.

    PubMed

    Polatkan, Gungor; Zhou, Mingyuan; Carin, Lawrence; Blei, David; Daubechies, Ingrid

    2015-02-01

    Super-resolution methods form high-resolution images from low-resolution images. In this paper, we develop a new Bayesian nonparametric model for super-resolution. Our method uses a beta-Bernoulli process to learn a set of recurring visual patterns, called dictionary elements, from the data. Because it is nonparametric, the number of elements found is also determined from the data. We test the results on both benchmark and natural images, comparing with several other models from the research literature. We perform large-scale human evaluation experiments to assess the visual quality of the results. In a first implementation, we use Gibbs sampling to approximate the posterior. However, this algorithm is not feasible for large-scale data. To circumvent this, we then develop an online variational Bayes (VB) algorithm. This algorithm finds high quality dictionaries in a fraction of the time needed by the Gibbs sampler.

  3. Perceptual compression of magnitude-detected synthetic aperture radar imagery

    NASA Technical Reports Server (NTRS)

    Gorman, John D.; Werness, Susan A.

    1994-01-01

    A perceptually-based approach for compressing synthetic aperture radar (SAR) imagery is presented. Key components of the approach are a multiresolution wavelet transform, a bit allocation mask based on an empirical human visual system (HVS) model, and hybrid scalar/vector quantization. Specifically, wavelet shrinkage techniques are used to segregate wavelet transform coefficients into three components: local means, edges, and texture. Each of these three components is then quantized separately according to a perceptually-based bit allocation scheme. Wavelet coefficients associated with local means and edges are quantized using high-rate scalar quantization while texture information is quantized using low-rate vector quantization. The impact of the perceptually-based multiresolution compression algorithm on visual image quality, impulse response, and texture properties is assessed for fine-resolution magnitude-detected SAR imagery; excellent image quality is found at bit rates at or above 1 bpp along with graceful performance degradation at rates below 1 bpp.

  4. Looking inward and back: Real-time monitoring of visual working memories.

    PubMed

    Suchow, Jordan W; Fougnie, Daryl; Alvarez, George A

    2017-04-01

    Confidence in our memories is influenced by many factors, including beliefs about the perceptibility or memorability of certain kinds of objects and events, as well as knowledge about our skill sets, habits, and experiences. Notoriously, our knowledge and beliefs about memory can lead us astray, causing us to be overly confident in eyewitness testimony or to overestimate the frequency of recent experiences. Here, using visual working memory as a case study, we stripped away all these potentially misleading cues, requiring observers to make confidence judgments by directly assessing the quality of their memory representations. We show that individuals can monitor the status of information in working memory as it degrades over time. Our findings suggest that people have access to information reflecting the existence and quality of their working memories, and furthermore, that they can use this information to guide their behavior. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Evaluating the Quality of Life of Glaucoma Patients Using the State-Trait Anxiety Inventory.

    PubMed

    Otori, Yasumasa; Takahashi, Genichiro; Urashima, Mitsuyoshi; Kuwayama, Yasuaki

    2017-11-01

    To evaluate anxiety felt by glaucoma patients. In total, 472 glaucoma patients responded to a questionnaire on anxiety, subjective symptoms, and vision-related quality of life (VR-QOL) associated with glaucoma. Anxiety was evaluated using the State-Trait Anxiety Inventory (STAI), state anxiety (STAI-State) subscale along with our novel questionnaire, assessing visual function and subjective symptoms, specialized for glaucoma. VR-QOL was evaluated using 5 subitems from the 25-item National Eye Institute Visual Function Questionnaire (VFQ-25). Adherence to ophthalmic antiglaucoma agents was confirmed. As indexes of visual function, corrected visual acuity (measured by eye chart), mean deviation (MD) score (measured with static perimetry), and 4 thresholds at the center of vision were determined. Stages were classified according to the Aulhorn Classification. From the STAI-State scores, the prevalence of anxiety in glaucoma patients was evaluated. We analyzed the correlation between the STAI-State and VFQ-25, anxiety, subjective symptoms, adherence, and visual function indexes. In total, 78% of glaucoma patients experienced at least an intermediate level of anxiety. The STAI-State correlated significantly with anxiety and subjective symptoms as measured by our novel questionnaire, particularly for questions "current anxiety about loss of vision" and "current anxiety in life" (r=0.468 and 0.500; both P<0.0001). However, STAI-State correlated weakly with VFQ-25, and not at all with visual function indexes and adherence. Many glaucoma patients feel anxiety. The STAI-State is correlated with the VR-QOL and anxiety in glaucoma patients, making it useful for understanding the anxiety present in glaucoma patients.

  6. Machinability of Minor Wooden Species before and after Modification with Thermo-Vacuum Technology

    PubMed Central

    Sandak, Jakub; Goli, Giacomo; Cetera, Paola; Sandak, Anna; Cavalli, Alberto; Todaro, Luigi

    2017-01-01

    The influence of the thermal modification process on wood machinability was investigated with four minor species of low economic importance. A set of representative experimental samples was machined to the form of disks with sharp and dull tools. The resulting surface quality was visually evaluated by a team of experts according to the American standard procedure ASTM D-1666-87. The objective quantification of the surface quality was also done by means of a three dimensions (3D) surface scanner for the whole range of grain orientations. Visual assessment and 3D surface analysis showed a good agreement in terms of conclusions. The best quality of the wood surface was obtained when machining thermally modified samples. The positive effect of the material modification was apparent when cutting deodar cedar, black pine and black poplar in unfavorable conditions (i.e., against the grain). The difference was much smaller for an easy-machinability specie such as Italian alder. The use of dull tools resulted in the worst surface quality. Thermal modification has shown a very positive effect when machining with dull tools, leading to a relevant increment of the final surface smoothness. PMID:28772480

  7. Effects of task and image properties on visual-attention deployment in image-quality assessment

    NASA Astrophysics Data System (ADS)

    Alers, Hani; Redi, Judith; Liu, Hantao; Heynderickx, Ingrid

    2015-03-01

    It is important to understand how humans view images and how their behavior is affected by changes in the properties of the viewed images and the task they are given, particularly the task of scoring the image quality (IQ). This is a complex behavior that holds great importance for the field of image-quality research. This work builds upon 4 years of research work spanning three databases studying image-viewing behavior. Using eye-tracking equipment, it was possible to collect information on human viewing behavior of different kinds of stimuli and under different experimental settings. This work performs a cross-analysis on the results from all these databases using state-of-the-art similarity measures. The results strongly show that asking the viewers to score the IQ significantly changes their viewing behavior. Also muting the color saturation seems to affect the saliency of the images. However, a change in IQ was not consistently found to modify visual attention deployment, neither under free looking nor during scoring. These results are helpful in gaining a better understanding of image viewing behavior under different conditions. They also have important implications on work that collects subjective image-quality scores from human observers.

  8. Machinability of Minor Wooden Species before and after Modification with Thermo-Vacuum Technology.

    PubMed

    Sandak, Jakub; Goli, Giacomo; Cetera, Paola; Sandak, Anna; Cavalli, Alberto; Todaro, Luigi

    2017-01-28

    The influence of the thermal modification process on wood machinability was investigated with four minor species of low economic importance. A set of representative experimental samples was machined to the form of disks with sharp and dull tools. The resulting surface quality was visually evaluated by a team of experts according to the American standard procedure ASTM D-1666-87. The objective quantification of the surface quality was also done by means of a three dimensions (3D) surface scanner for the whole range of grain orientations. Visual assessment and 3D surface analysis showed a good agreement in terms of conclusions. The best quality of the wood surface was obtained when machining thermally modified samples. The positive effect of the material modification was apparent when cutting deodar cedar, black pine and black poplar in unfavorable conditions (i.e., against the grain). The difference was much smaller for an easy-machinability specie such as Italian alder. The use of dull tools resulted in the worst surface quality. Thermal modification has shown a very positive effect when machining with dull tools, leading to a relevant increment of the final surface smoothness.

  9. Course for undergraduate students: analysis of the retinal image quality of a human eye model

    NASA Astrophysics Data System (ADS)

    del Mar Pérez, Maria; Yebra, Ana; Fernández-Oliveras, Alicia; Ghinea, Razvan; Ionescu, Ana M.; Cardona, Juan C.

    2014-07-01

    In teaching of Vision Physics or Physiological Optics, the knowledge and analysis of the aberration that the human eye presents are of great interest, since this information allows a proper evaluation of the quality of the retinal image. The objective of the present work is that the students acquire the required competencies which will allow them to evaluate the optical quality of the human visual system for emmetropic and ammetropic eye, both with and without the optical compensation. For this purpose, an optical system corresponding to the Navarro-Escudero eye model, which allows calculating and evaluating the aberration of this eye model in different ammetropic conditions, was developed employing the OSLO LT software. The optical quality of the visual system will be assessed through determinations of the third and fifth order aberration coefficients, the impact diagram, wavefront analysis, calculation of the Point Spread Function and the Modulation Transfer Function for ammetropic individuals, with myopia or hyperopia, both with or without the optical compensation. This course is expected to be of great interest for student of Optics and Optometry Sciences, last courses of Physics or medical sciences related with human vision.

  10. A water quality management strategy for regionally protected water through health risk assessment and spatial distribution of heavy metal pollution in 3 marine reserves.

    PubMed

    Zhang, Yinan; Chu, Chunli; Li, Tong; Xu, Shengguo; Liu, Lei; Ju, Meiting

    2017-12-01

    Severe water pollution and resource scarcity is a major problem in China, where it is necessary to establish water quality-oriented monitoring and intelligent watershed management. In this study, an effective watershed management method is explored, in which water quality is first assessed using the heavy metal pollution index and the human health risk index, and then by classifying the pollution and management grade based on cluster analysis and GIS visualization. Three marine reserves in Tianjin were selected and analyzed, namely the Tianjin Ancient Coastal Wetland National Nature Reserve (Qilihai Natural Reserve), the Tianjin DaShentang Oyster Reef National Marine Special Reserve (DaShentang Reserve), and the Tianjin Coastal Wetland National Marine Special Reserve (BinHai Wetland Reserve) which is under construction. The water quality and potential human health risks of 5 heavy metals (Pb, As, Cd, Hg, Cr) in the three reserves were assessed using the Nemerow index and USEPA methods. Moreover, ArcGIS10.2 software was used to visualize the heavy metal index and display their spatial distribution. Cluster analysis enabled classification of the heavy metals into 4 categories, which allowed for identification of the heavy metals whose pollution index and health risks were highest, and, thus, whose control in the reserve is a priority. Results indicate that heavy metal pollution exists in the Qilihai Natural Reserve and in the north and east of the DaShentang Reserve; furthermore, human health risks exist in the Qilihai Natural Reserve and in the BinHai Wetland Reserve. In each reserve, the main factor influencing the pollution and health risk were high concentrations of As and Pb that exceed the corresponding standards. Measures must be adopted to control and remediate the pollutants. Furthermore, to protect the marine reserves, management policies must be implemented to improve water quality, which is an urgent task for both local and national governments. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Comparison of Acid Titration, Conductivity, Flame Photometry, ICP-MS, and Accelerated Lamellae Formation Techniques in Determining Glass Vial Quality.

    PubMed

    Fujimori, Kiyoshi; Lee, Hans; Sloey, Christopher; Ricci, Margaret S; Wen, Zai-Qing; Phillips, Joseph; Nashed-Samuel, Yasser

    2016-01-01

    Certain types of glass vials used as primary containers for liquid formulations of biopharmaceutical drug products have been observed with delamination that produced small glass like flakes termed lamellae under certain conditions during storage. The cause of this delamination is in part related to the glass surface defects, which renders the vials susceptible to flaking, and lamellae are formed during the high-temperature melting and annealing used for vial fabrication and shaping. The current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. Four alternative techniques with improved throughput, convenience, and/or comprehension were examined by subjecting seven lots of vials to analysis by all techniques. The first three new techniques of conductivity, flame photometry, and inductively coupled plasma mass spectrometry measured the same sample pools as acid titration. All three showed good correlation with alkalinity: conductivity (R(2) = 0.9951), flame photometry sodium (R(2) = 0.9895), and several elements by inductively coupled plasma mass spectrometry [(sodium (R(2) = 0.9869), boron (R(2) = 0.9796), silicon (R(2) = 0.9426), total (R(2) = 0.9639)]. The fourth technique processed the vials under conditions that promote delamination, termed accelerated lamellae formation, and then inspected those vials visually for lamellae. The visual inspection results without the lot with different processing condition correlated well with alkalinity (R(2) = 0.9474). Due to vial processing differences affecting alkalinity measurements and delamination propensity differently, the ratio of silicon and sodium measurements from inductively coupled plasma mass spectrometry was the most informative technique to assess overall vial quality and vial propensity for lamellae formation. The other techniques of conductivity, flame photometry, and accelerated lamellae formation condition may still be suitable for routine screening of vial lots produced under consistent processes. Recently, delamination that produced small glass like flakes termed lamellae has been observed in glass vials that are commonly used as primary containers for pharmaceutical drug products under certain conditions during storage. The main cause of these lamellae was the quality of the glass itself related to the manufacturing process. Current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. As alternative to the European Pharmacopoeia method, four other techniques were assessed. Three new techniques of conductivity, flame photometry, and inductively coupled plasma mass spectrometry measured the vial extract pool as acid titration to quantify quality, and they demonstrated good correlation with original alkalinity. The fourth technique processed the vials under conditions that promote delamination, termed accelerated lamellae formation, and the vials were then inspected visually for lamellae. The accelerated lamellae formation technique also showed good correlation with alkalinity. Of the new four techniques, inductively coupled plasma mass spectrometry was the most informative technique to assess overall vial quality even with differences in processing between vial lots. Other three techniques were still suitable for routine screening of vial lots produced under consistent processes. © PDA, Inc. 2016.

  12. Assessment of Psychopathology and Quality of Life in Children and Adolescents With Migraine.

    PubMed

    Öztop, Didem Behice; Taşdelen, Bedia İnce; PoyrazoğLu, Hatıce Gamze; Ozsoy, Saliha; Yilmaz, Rabia; Şahın, Nilfer; Per, Hüseyin; Bozkurt, Selma

    2016-06-01

    The aims of this study were to investigate comorbid psychiatric disorders and to identify anxiety and depression levels and quality of life in children and adolescents with migraine; and to assess their relationship with migraine. 35 patients aged 9-16 years were followed in our neurology clinic and their parents were included into the study. 35 age- and sex-matched patients were employed as the control group. In the subjects included, psychiatric disorders were assessed by using the Schedule for Affective Disorders and Schizophrenia for School Age Children-Present and Lifetime Version. All children and adolescents were assessed by using the Children's Depression Inventory, the State-Trait Anxiety Inventory and the Pediatric Quality of Life Inventory. In addition, the Pediatric Migraine Disability Assessment Tool and visual analog scale were used to identify the degree of disability and pain severity in patients with migraine. In the psychiatric assessment of children and adolescents with migraine, it was found that a psychiatric diagnosis was made in 40% of patients; and depression scale scores were significantly higher than those of controls. Quality of life was found to be poorer in patients with migraine compared to controls. It was found that quality of life was negatively correlated with pain severity and degree of disability; while it was positively correlated with depression scores. In children and adolescents with migraine, treatment of psychiatric disorders in addition to migraine therapy can facilitate migraine management and may decrease the need for prophylactic therapy. © The Author(s) 2016.

  13. Interventions for visual field defects in patients with stroke.

    PubMed

    Pollock, Alex; Hazelton, Christine; Henderson, Clair A; Angilley, Jayne; Dhillon, Baljean; Langhorne, Peter; Livingstone, Katrina; Munro, Frank A; Orr, Heather; Rowe, Fiona J; Shahani, Uma

    2011-10-05

    Visual field defects are estimated to affect 20% to 57% of people who have had a stroke. Visual field defects can affect functional ability in activities of daily living (commonly affecting mobility, reading and driving), quality of life, ability to participate in rehabilitation, and depression, anxiety and social isolation following stroke. There are many interventions for visual field defects, which are proposed to work by restoring the visual field (restitution); compensating for the visual field defect by changing behaviour or activity (compensation); substituting for the visual field defect by using a device or extraneous modification (substitution); or ensuring appropriate diagnosis, referral and treatment prescription through standardised assessment or screening, or both. To determine the effects of interventions for people with visual field defects after stroke. We searched the Cochrane Stroke Group Trials Register (February 2011), the Cochrane Eyes and Vision Group Trials Register (December 2009) and nine electronic bibliographic databases including CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to December 2009), EMBASE (1980 to December 2009), CINAHL (1982 to December 2009), AMED (1985 to December 2009), and PsycINFO (1967 to December 2009). We also searched reference lists and trials registers, handsearched journals and conference proceedings and contacted experts. Randomised trials in adults after stroke, where the intervention was specifically targeted at improving the visual field defect or improving the ability of the participant to cope with the visual field loss. The primary outcome was functional ability in activities of daily living and secondary outcomes included functional ability in extended activities of daily living, reading ability, visual field measures, balance, falls, depression and anxiety, discharge destination or residence after stroke, quality of life and social isolation, visual scanning, adverse events and death. Two review authors independently screened abstracts, extracted data and appraised trials. We undertook an assessment of methodological quality for allocation concealment, blinding of outcome assessors, method of dealing with missing data, and other potential sources of bias. Thirteen studies (344 randomised participants, 285 of whom were participants with stroke) met the inclusion criteria for this review. However, only six of these studies compared the effect of an intervention with a placebo, control or no treatment group and were included in comparisons within this review. Four studies compared the effect of scanning (compensatory) training with a control or placebo intervention. Meta-analysis demonstrated that scanning training is more effective than control or placebo at improving reading ability (three studies, 129 participants; mean difference (MD) 3.24, 95% confidence interval (CI) 0.84 to 5.59) and visual scanning (three studies, 129 participants; MD 18.84, 95% CI 12.01 to 25.66) but that scanning may not improve visual field outcomes (two studies, 110 participants; MD -0.70, 95% CI -2.28 to 0.88). There were insufficient data to enable generalised conclusions to be made about the effectiveness of scanning training relative to control or placebo for the primary outcome of activities of daily living (one study, 33 participants). Only one study (19 participants) compared the effect of a restitutive intervention with a control or placebo intervention and only one study (39 participants) compared the effect of a substitutive intervention with a control or placebo intervention. There is limited evidence which supports the use of compensatory scanning training for patients with visual field defects (and possibly co-existing visual neglect) to improve scanning and reading outcomes. There is insufficient evidence to reach a conclusion about the impact of compensatory scanning training on functional activities of daily living. There is insufficient evidence to reach generalised conclusions about the benefits of visual restitution training (VRT) (restitutive intervention) or prisms (substitutive intervention) for patients with visual field defects after stroke.

  14. The Use of UV-Visible Reflectance Spectroscopy as an Objective Tool to Evaluate Pearl Quality

    PubMed Central

    Agatonovic-Kustrin, Snezana; Morton, David W.

    2012-01-01

    Assessing the quality of pearls involves the use of various tools and methods, which are mainly visual and often quite subjective. Pearls are normally classified by origin and are then graded by luster, nacre thickness, surface quality, size, color and shape. The aim of this study was to investigate the capacity of Artificial Neural Networks (ANNs) to classify and estimate the quality of 27 different pearls from their UV-Visible spectra. Due to the opaque nature of pearls, spectroscopy measurements were performed using the Diffuse Reflectance UV-Visible spectroscopy technique. The spectra were acquired at two different locations on each pearl sample in order to assess surface homogeneity. The spectral data (inputs) were smoothed to reduce the noise, fed into ANNs and correlated to the pearl’s quality/grading criteria (outputs). The developed ANNs were successful in predicting pearl type, mollusk growing species, possible luster and color enhancing, donor condition/type, recipient/host color, donor color, pearl luster, pearl color, origin. The results of this study shows that the developed UV-Vis spectroscopy-ANN method could be used as a more objective method of assessing pearl quality (grading) and may become a valuable tool for the pearl grading industry. PMID:22851919

  15. Water quality trends in New Zealand rivers: 1989-2009.

    PubMed

    Ballantine, Deborah J; Davies-Colley, Robert J

    2014-03-01

    Recent assessments of water quality in New Zealand have indicated declining trends, particularly in the 40 % of the country's area under pasture. The most comprehensive long-term and consistent water quality dataset is the National Rivers Water Quality Network (NRWQN). Since 1989, monthly samples have been collected at 77 NRWQN sites on 35 major river systems that, together, drain about 50 % of New Zealand's land area. Trend analysis of the NRWQN data shows increasing nutrient concentrations, particularly nitrogen (total nitrogen and nitrate), over 21 years (1989-2009). Total nitrogen and nitrate concentrations were increasing significantly over the first 11 years (1989-2000), but for the more recent 10-year period, only nitrate concentrations continued to increase sharply. Also, the increasing phosphorus trends over the first 11 years (1989-2000) levelled off over the later 10-year period (2000-2009). Conductivity has also increased over the 21 years (1989-2009). Visual clarity has increased over the full time period which may be the positive result of soil conservation measures and riparian fencing. NRWQN data shows that concentrations of nutrients increase, and visual clarity decreases (i.e. water quality declines), with increasing proportions of pastoral land in catchments. As such, the increasing nutrient trends may reflect increasing intensification of pastoral agriculture.

  16. Convolutional auto-encoder for image denoising of ultra-low-dose CT.

    PubMed

    Nishio, Mizuho; Nagashima, Chihiro; Hirabayashi, Saori; Ohnishi, Akinori; Sasaki, Kaori; Sagawa, Tomoyuki; Hamada, Masayuki; Yamashita, Tatsuo

    2017-08-01

    The purpose of this study was to validate a patch-based image denoising method for ultra-low-dose CT images. Neural network with convolutional auto-encoder and pairs of standard-dose CT and ultra-low-dose CT image patches were used for image denoising. The performance of the proposed method was measured by using a chest phantom. Standard-dose and ultra-low-dose CT images of the chest phantom were acquired. The tube currents for standard-dose and ultra-low-dose CT were 300 and 10 mA, respectively. Ultra-low-dose CT images were denoised with our proposed method using neural network, large-scale nonlocal mean, and block-matching and 3D filtering. Five radiologists and three technologists assessed the denoised ultra-low-dose CT images visually and recorded their subjective impressions of streak artifacts, noise other than streak artifacts, visualization of pulmonary vessels, and overall image quality. For the streak artifacts, noise other than streak artifacts, and visualization of pulmonary vessels, the results of our proposed method were statistically better than those of block-matching and 3D filtering (p-values < 0.05). On the other hand, the difference in the overall image quality between our proposed method and block-matching and 3D filtering was not statistically significant (p-value = 0.07272). The p-values obtained between our proposed method and large-scale nonlocal mean were all less than 0.05. Neural network with convolutional auto-encoder could be trained using pairs of standard-dose and ultra-low-dose CT image patches. According to the visual assessment by radiologists and technologists, the performance of our proposed method was superior to that of large-scale nonlocal mean and block-matching and 3D filtering.

  17. Severity of Visual Field Loss and Health Related Quality of Life

    PubMed Central

    McKean-Cowdin, Roberta; Varma, Rohit; Wu, Joanne; Hays, Ron D.; Azen, Stanley P.

    2009-01-01

    Purpose To examine the association between severity of visual field loss (VFL) and self-reported health-related quality of life (HRQOL) in a population-based sample. Design Population-based cross-sectional study. Methods Participants in the Los Angeles Latino Eye Study underwent a comprehensive ophthalmic examination including visual field testing using the Humphrey Automated Field Analyzer II (SITA Standard 24-2). Mean Deviation (MD) scores were used to determine severity of VFL both as a continuous variable and stratified by severity: no VFL (MD≥ − 2 decibels [dB]), mild VFL (6dB

  18. Parent-child discrepancy in the assessment of health- related quality of life using the EQ-5D-Y questionnaire.

    PubMed

    Perez Sousa, Miguel Á; Olivares Sánchez-Toledo, Pedro R; Gusi Fuerte, Narcis

    2017-12-01

    The assessment of health-related quality of life (HRQoL) serves to detect changes over time in patients' health status and allows to do a cost-effectiveness analysis of treatments. When children with special health features cannot perform a self-assessment, it is possible to assess their HRQoL through their parents or caregivers. To date, the discrepancy in the assessment of HRQoL using the EQ-5D-Y questionnaire among children with cerebral palsy (CP) and their parents has not been analyzed. The objective of this study was to analyze the level of agreement in the HRQoL assessment using the EQ-5D-Y questionnaire and its proxy version among children with CP and their parents or caregivers. Children and adolescents with CP, and their parents, from a special education school in the region of Extremadura (Spain) participated in the study. The EQ-5D-Y questionnaire was used for children and the EQ-5D-Y proxy version, for parents. Interviews were conducted in the first quarter of 2015. The level of agreement in the responses was analyzed using the Cohen's kappa coefficient for the five domains of the EQ-5D-Y and the intraclass correlation coefficient for the visual analogue scale. Sixty-two children with CP and mild and/or moderate functional capacity impairment, and their parents, participated in the study. The level of agreement was poor in the HRQoL assessment between children and parents in all the questionnaire domains ( <0.20) and fair or poor ( <0.60) in the visual analogue scale. A high level of parent-child disagreement was observed in the HRQoL assessment in the population with CP using the EQ-5D-Y questionnaire. Sociedad Argentina de Pediatría

  19. [Evolution of symptoms and quality of life of patients after surgery of digestive endometriosis].

    PubMed

    Bailly, E; Margulies, A-L; Letohic, A; Fraleu-Louër, B; Renouvel, F; Panel, P

    2013-11-01

    Prospective evaluation of symptoms and quality of life before and after surgical treatment of endometriosis with bowel involvement. Changes in symptoms, sexuality and quality of life before and after surgery of 41 patients operated for bowel endometriosis at the centre hospitalier de Versailles (CHV) were assessed with a self-assessment questionnaire. Pains were assessed using five visual analog scales, symptoms using 26 questions with a four-level Likert item, sexuality using the SEXACQ, and quality of life using the EHP-5 and the EQ-5D VAS. Surgical treatment improves pain: VAS scores for main pain (P<0.0001), dysmenorrhea (P=0.0039), defecation pain (P=0.0312), non-cyclic pelvic pain (P=0.0002), and dyspareunia (P=0.0084). Twelve intestinal symptoms are improved, including three significantly. It also improves SEXACQ score (P=0.0068) and quality of life scores EHP-5 and EQ-5D VAS (P=0.0001 and P=0.0003 respectively). No difference was found between disk resection and segmental resection in terms of symptoms, sexuality and quality of life. Histological analysis suggests that when a segmental resection is done, the stage of the endometriosis bowel involvement is more advanced. Surgery of bowel endometriosis improves symptoms and quality of life. When the stage of the bowel endometriosis is advanced, a segmental resection should be done. Moreover, self-assessment questionnaire used at the CHV seems an appropriate tool to evaluate functional outcome. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    PubMed

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye tracking literature in radiology indicates several search patterns are related to high levels of expertise, but teaching novices to search as an expert may not be effective. Experimental research is needed to find out which search strategies can improve image perception in learners.

  1. The Impact of Change in Visual Field on Health-Related Quality of Life: The Los Angeles Latino Eye Study

    PubMed Central

    Patino, Cecilia M.; Varma, Rohit; Azen, Stanley P.; Conti, David V.; Nichol, Michael B.; McKean-Cowdin, Roberta

    2010-01-01

    Purpose To assess the impact of change in visual field (VF) on change in health related quality of life (HRQoL) at the population level. Design Prospective cohort study Participants 3,175 Los Angles Latino Eye Study (LALES) participants Methods Objective measures of VF and visual acuity and self-reported HRQoL were collected at baseline and 4-year follow-up. Analysis of covariance was used to evaluate mean differences in change of HRQoL across severity levels of change in VF and to test for effect modification by covariates. Main outcome measures General and vision-specific HRQoL. Results Of 3,175 participants, 1430 (46%) showed a change in VF (≥1 decibel [dB]) and 1651, 1715 (54%) reported a clinically important change (≥5 points) in vision-specific HRQoL. Progressive worsening and improvement in the VF were associated with increasing losses and gains in vision-specific HRQoL for the composite score and 10 of its 11 subscales (all Ptrends<0.05). Losses in VF > 5 dB and gains > 3 dB were associated with clinically meaningful losses and gains in vision-specific HRQoL, respectively. Areas of vision-specific HRQoL most affected by greater losses in VF were driving, dependency, role-functioning, and mental health. The effect of change in VF (loss or gain) on mean change in vision-specific HRQoL varied by level of baseline vision loss (in visual field and/or visual acuity) and by change in visual acuity (all P-interactions<0.05). Those with moderate/severe VF loss at baseline and with a > 5 dB loss in visual field during the study period had a mean loss of vision-specific HRQoL of 11.3 points, while those with no VF loss at baseline had a mean loss of 0.97 points Similarly, with a > 5 dB loss in VF and baseline visual acuity impairment (mild/severe) there was a loss in vision-specific HRQoL of 10.5 points, whereas with no visual acuity impairment at baseline there was a loss of vision-specific HRQoL of 3.7 points. Conclusion Both losses and gains in VF produce clinically meaningful changes in vision-specific HRQoL. In the presence of pre-existing vision loss (VF and visual acuity), similar levels of visual field change produce greater losses in quality of life. PMID:21458074

  2. Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

    PubMed

    Sekine, Tetsuro; Amano, Yasuo; Takagi, Ryo; Matsumura, Yoshio; Murai, Yasuo; Kumita, Shinichiro

    2014-01-01

    A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. Sixteen volunteers underwent 3 types of 4D Flow MR imaging of the brain using a 3.0-tesla scanner. As the standard scan, 4D Flow MR imaging with SENSE was performed first and then followed by 2 types of acceleration scan-with Cartesian y-z radial sampling and with k-t SENSE. We measured peak systolic velocity (PSV) and blood flow volume (BFV) in 9 arteries, and the percentage of particles arriving from the emitter plane at the target plane in 3 arteries, visually graded image quality in 9 arteries, and compared these quantitative and visual data between the standard scan and each acceleration scan. 4D Flow MR imaging examinations were completed in all but one volunteer, who did not undergo the last examination because of headache. Each acceleration scan reduced scan time by 50% compared with the standard scan. The k-t SENSE imaging underestimated PSV and BFV (P < 0.05). There were significant correlations for PSV and BFV between the standard scan and each acceleration scan (P < 0.01). The percentage of particles reaching the target plane did not differ between the standard scan and each acceleration scan. For visual assessment, y-z radial sampling deteriorated the image quality of the 3 arteries. Cartesian y-z radial sampling is feasible for measuring flow, and k-t SENSE offers sufficient flow visualization; both allow acquisition of 4D Flow MR imaging with shorter scan time.

  3. Quantitative evaluation of vision-related and health-related quality of life after endoscopic transsphenoidal surgery for pituitary adenoma.

    PubMed

    Wolf, Amparo; Coros, Alexandra; Bierer, Joel; Goncalves, Sandy; Cooper, Paul; Van Uum, Stan; Lee, Donald H; Proulx, Alain; Nicolle, David; Fraser, J Alexander; Rotenberg, Brian W; Duggal, Neil

    2017-08-01

    OBJECTIVE Endoscopic resection of pituitary adenomas has been reported to improve vision function in up to 80%-90% of patients with visual impairment due to these adenomas. It is unclear how these reported rates translate into improvement in visual outcomes and general health as perceived by the patients. The authors evaluated self-assessed health-related quality of life (HR-QOL) and vision-related QOL (VR-QOL) in patients before and after endoscopic resection of pituitary adenomas. METHODS The authors prospectively collected data from 50 patients who underwent endoscopic resection of pituitary adenomas. This cohort included 32 patients (64%) with visual impairment preoperatively. Twenty-seven patients (54%) had pituitary dysfunction, including 17 (34%) with hormone-producing tumors. Patients completed the National Eye Institute Visual Functioning Questionnaire and the 36-Item Short Form Health Survey preoperatively and 6 weeks and 6 months after surgery. RESULTS Patients with preoperative visual impairment reported a significant impact of this condition on VR-QOL preoperatively, including general vision, near activities, and peripheral vision; they also noted vision-specific impacts on mental health, role difficulties, dependency, and driving. After endoscopic resection of adenomas, patients reported improvement across all these categories 6 weeks postoperatively, and this improvement was maintained by 6 months postoperatively. Patients with preoperative pituitary dysfunction, including hormone-producing tumors, perceived their general health and physical function as poorer, with some of these patients reporting improvement in perceived general health after the endoscopic surgery. All patients noted that their ability to work or perform activities of daily living was transiently reduced 6 weeks postoperatively, followed by significant improvement by 6 months after the surgery. CONCLUSIONS Both VR-QOL and patient's perceptions of their ability to do work and perform other daily activities as a result of their physical health significantly improved by 6 months after endoscopic resection of pituitary adenoma. The use of multidimensional QOL questionnaires provides a precise assessment of perceived outcomes after endoscopic surgery.

  4. Relationship of cataract symptoms of preoperative patients and vision-related quality of life.

    PubMed

    Lee, Jae Eun; Fos, Peter J; Sung, Jung Hye; Amy, Brian W; Zuniga, Miguel A; Lee, Won Jae; Kim, Jae Chang

    2005-10-01

    This study was conducted in an attempt to describe the status of cataract symptoms of preoperative cataract patients, as well as to determine the relationship between cataract symptom and vision-related quality of life measures. A cross-sectional study design was used. Study subjects were selected using non-probabilistic methods. The study sample consisted of 132 patients scheduled for cataract surgery in one eye. Information was obtained from study subjects by conducting face-to-face interviews. Study subjects were adult cataract patients at Samsung and Kunyang General Hospitals in Seoul, Korea, and Tulane University Hospital and Clinics in New Orleans, Louisiana, United States of America. Degree to which study subjects were "bothered" by cataract symptoms was measured by using the 5-item Cataract Symptom Scores (CSS). The number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean of cataract symptom score were created based on the CSS measure. Vision-related quality of life was assessed by using the Visual Function 14 Items (VF-14) and Global Measure of Vision (GMV) for trouble and satisfaction. The symptoms "blurry vision" and "worsening of vision" were most frequently reported. The symptom "colors looking different" was rarely reported among preoperative cataract patients. The degree to which study subjects were bothered by "blurry vision" and "seeing glare, halo, or rings" was highly associated with visual function, visual trouble, and visual satisfaction. Multiple regression analysis revealed that the newly developed cataract symptom-related scales, as well as total amount of degree to which study subjects were "bothered" by symptoms were highly related to vision-related quality of life measures. These relationships were persistent after controlling for major socio-demographic variables. The results indicate that cataract symptoms are highly associated with vision-related quality of life. The results also suggest that the number of symptoms, highest scored symptom among the five, number of symptoms extremely bothering, and the mean cataract symptom scores should be considered an important cataract symptom-related scale when analyzing quality of life, including cataract symptom.

  5. Incorporating Quality of Life Metrics in Interventional Oncology Practice.

    PubMed

    Li, David; Madoff, David C

    2017-12-01

    Interventional radiologists care for a large number of cancer patients with the breadth of palliative intent minimally invasive procedures that we provide. Understanding our meaningful impact on patients' quality of life is essential toward validating our role in the palliation of cancer patients. As such, it is critically important for interventional radiologists to understand common instruments used for the reporting of patient's quality of life measures. Common instruments used to measure pain and quality of life for cancer patients include the numerical rating scale, visual analog scale, brief pain inventory, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire, and the Functional Assessment of Cancer Therapy. An ideal quality of life instrument should be a patient reported outcome measure across multiple domains (e.g., physical health, psychological, social), and be both validated and reliable.

  6. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    PubMed

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  7. Sleep Disturbances among Persons Who Are Visually Impaired: Survey of Dog Guide Users.

    ERIC Educational Resources Information Center

    Fouladi, Massoud K.; Moseley, Merrick J.; Jones, Helen S.; Tobin, Michael J.

    1998-01-01

    A survey completed by 1237 adults with severe visual impairments found that 20% described the quality of their sleep as poor or very poor. Exercise was associated with better sleep and depression with poorer sleep. However, visual acuity did not predict sleep quality, casting doubt on the idea that restricted visual input (light) causes sleep…

  8. The Challenges of Educating the Visually Impaired and Quality Assurance in Tertiary Institutions of Learning in Nigeria

    ERIC Educational Resources Information Center

    Omede, Andrew A.

    2015-01-01

    This paper focused on the challenges in educating the visually impaired and modalities for ensuring quality assurance in tertiary institutions of learning in Nigeria. It examined the global challenges in the higher educational system and made it clear that the visually impaired are those with visual problems be it partial, low vision, or total…

  9. Dosimetry and image quality assessment in a direct radiography system

    PubMed Central

    Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2014-01-01

    Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119

  10. Treatment of facial lipoatrophy with polymethylmethacrylate among patients with human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS): impact on the quality of life.

    PubMed

    Quintas, Rodrigo C S; de França, Emmanuel R; de Petribú, Kátia C L; Ximenes, Ricardo A A; Quintas, Lóren F F M; Cavalcanti, Ernando L F; Kitamura, Marco A P; Magalhães, Kássia A A; Paiva, Késsia C F; Filho, Demócrito B Miranda

    2014-04-01

    The lipodystrophy syndrome is characterized by selective loss of subcutaneous fat on the face and extremities (lipoatrophy) and/or accumulation of fat around the neck, abdomen, and thorax (lipohypertrophy). The aim of this study has been to assess the impact of polymethylmethacrylate facial treatment on quality of life, self-perceived facial image, and the severity of depressive symptoms in patients living with HIV/AIDS. A non-randomized before and after interventional study was developed. Fifty-one patients underwent facial filling. The self-perceived quality of life, facial image, and degree of depressive symptoms were measured by the Short-Form 36 and HIV/AIDS--Targeted quality of life questionnaires, by a visual analogue scale and by the Beck depression inventory, respectively, before and three months after treatment. Six of the eight domains of Short-Form 36 and eight of the nine dimensions of the HIV/AIDS--Targeted quality of life questionnaires, together with the visual analogue scale and by the Beck depression inventory scores, revealed a statistically significant improvement. The only adverse effects registered were edema and ecchymosis. The treatment of facial lipoatrophy improved the self-perceived quality of life and facial image as well as any depressive symptoms among patients with HIV/AIDS. © 2014 The International Society of Dermatology.

  11. Data visualization, time-series analysis, and mass-balance modeling of hydrologic and water-quality data for the McTier Creek watershed, South Carolina, 2007-2009

    USGS Publications Warehouse

    Benedict, Stephen T.; Conrads, Paul; Feaster, Toby D.; Journey, Celeste A.; Golden, Heather E.; Knightes, Christopher D.; Davis, Gary M.; Bradley, Paul M.

    2012-01-01

    The McTier Creek watershed is located in the headwaters of the Edisto River Basin, which is in the Coastal Plain region of South Carolina. The Edisto ecosystem has some of the highest recorded fish-tissue mercury concentrations in the United States. In an effort to advance the understanding of the fate and transport of mercury in stream ecosystems, the U.S. Geological Survey, as part of its National Water-Quality Assessment Program, initiated a field investigation of mercury in the McTier Creek watershed in 2006. The initial efforts of the investigation included the collection of extensive hydrologic and water-quality field data, along with the development of several hydrologic and water-quality models. This series of measured and modeled data forms the primary source of information for this investigation to assess the fate and transport of mercury within the McTier Creek watershed.

  12. Identifying high quality medical education websites in Otolaryngology: a guide for medical students and residents.

    PubMed

    Yang, Nathan; Hosseini, Sarah; Mascarella, Marco A; Young, Meredith; Posel, Nancy; Fung, Kevin; Nguyen, Lily H P

    2017-05-25

    Learners often utilize online resources to supplement formalized curricula, and to appropriately support learning, these resources should be of high quality. Thus, the objectives of this study are to develop and provide validity evidence supporting an assessment tool designed to assess the quality of educational websites in Otolaryngology- Head & Neck Surgery (ORL-HNS), and identify those that could support effective web-based learning. METHODS: After a literature review, the Modified Education in Otolaryngology Website (MEOW) assessment tool was designed by a panel of experts based on a previously validated website assessment tool. A search strategy using a Google-based search engine was used subsequently to identify websites. Those that were free of charge and in English were included. Websites were coded for whether their content targeted medical students or residents. Using the MEOW assessment tool, two independent raters scored the websites. Inter-rater and intra-rater reliability were evaluated, and scores were compared to recommendations from a content expert. The MEOW assessment tool included a total of 20 items divided in 8 categories related to authorship, frequency of revision, content accuracy, interactivity, visual presentation, navigability, speed and recommended hyperlinks. A total of 43 out of 334 websites identified by the search met inclusion criteria. The scores generated by our tool appeared to differentiate higher quality websites from lower quality ones: websites that the expert "would recommend" scored 38.4 (out of 56; CI [34.4-42.4]) and "would not recommend" 27.0 (CI [23.2-30.9]). Inter-rater and intra-rater intraclass correlation coefficient were greater than 0.7. Using the MEOW assessment tool, high quality ORL-HNS educational websites were identified.

  13. Patient Satisfaction Reporting After Total Hip Arthroplasty: A Systematic Review.

    PubMed

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Schairer, William W; Steinhaus, Michael E; Cross, Michael B

    2017-05-01

    This review evaluated the quality of patient satisfaction reporting after total hip arthroplasty. The initial search of the MEDLINE database yielded 755 studies. Twenty-four met the inclusion criteria. Most studies provided level III or IV evidence (n=15, 62.5%). The most common method used to assess satisfaction was the 10-point visual analog scale (7 studies, 29.2%), followed by an ordinal satisfaction scale (6 studies, 25.0%). The quality of evidence was poor, and the methods used to assess satisfaction were not standardized. Further research is needed to define the factors that affect patient satisfaction after total hip arthroplasty and how satisfaction is best measured. [Orthopedics. 2017; 40(3):e400-e404.]. Copyright 2017, SLACK Incorporated.

  14. A systematic review: the influence of real time feedback on wheelchair propulsion biomechanics.

    PubMed

    Symonds, Andrew; Barbareschi, Giulia; Taylor, Stephen; Holloway, Catherine

    2018-01-01

    Clinical guidelines recommend that, in order to minimize upper limb injury risk, wheelchair users adopt a semi-circular pattern with a slow cadence and a large push arc. To examine whether real time feedback can be used to influence manual wheelchair propulsion biomechanics. Clinical trials and case series comparing the use of real time feedback against no feedback were included. A general review was performed and methodological quality assessed by two independent practitioners using the Downs and Black checklist. The review was completed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta Analyses (PRISMA) guidelines. Six papers met the inclusion criteria. Selected studies involved 123 participants and analysed the effect of visual and, in one case, haptic feedback. Across the studies it was shown that participants were able to achieve significant changes in propulsion biomechanics, when provided with real time feedback. However, the effect of targeting a single propulsion variable might lead to unwanted alterations in other parameters. Methodological assessment identified weaknesses in external validity. Visual feedback could be used to consistently increase push arc and decrease push rate, and may be the best focus for feedback training. Further investigation is required to assess such intervention during outdoor propulsion. Implications for Rehabilitation Upper limb pain and injuries are common secondary disorders that negatively affect wheelchair users' physical activity and quality of life. Clinical guidelines suggest that manual wheelchair users should aim to propel with a semi-circular pattern with low a push rate and large push arc in the range in order to minimise upper limbs' loading. Real time visual and haptic feedback are effective tools for improving propulsion biomechanics in both complete novices and experienced manual wheelchair users.

  15. Rotary-wing flight test methods used for the evaluation of night vision devices

    NASA Astrophysics Data System (ADS)

    Haworth, Loran A.; Blanken, Christopher J.; Szoboszlay, Zoltan P.

    2001-08-01

    The U.S. Army Aviation mission includes flying helicopters at low altitude, at night, and in adverse weather. Night Vision Devices (NVDs) are used to supplement the pilot's visual cues for night flying. As the military requirement to conduct night helicopter operations has increased, the impact of helicopter flight operations with NVD technology in the Degraded Visual Environment (DVE) became increasingly important to quantify. Aeronautical Design Standard-33 (ADS- 33) was introduced to update rotorcraft handling qualities requirements and to quantify the impact of the NVDs in the DVE. As reported in this paper, flight test methodology in ADS-33 has been used by the handling qualities community to measure the impact of NVDs on task performance in the DVE. This paper provides the background and rationale behind the development of ADS-33 flight test methodology for handling qualities in the DVE, as well as the test methodology developed for human factor assessment of NVDs in the DVE. Lessons learned, shortcomings and recommendations for NVD flight test methodology are provided in this paper.

  16. The physical environment of purpose-built and non-purpose-built supported housing for persons with psychiatric disabilities in Sweden.

    PubMed

    Johansson, Maria; Brunt, David

    2012-04-01

    The primary aim of the present study was to investigate if methods derived from environmental psychology can be used to study the qualities of the physical environment of supported housing facilities for persons with psychiatric disabilities. Three units of analysis were selected: the private area, the common indoor area, and the outdoor area. Expert assessments of 110 features of the physical environment in these units and semantic environmental description of the visual experience of them consistently showed that purpose-built supported housing facilities had more physical features important for high quality residential environments than the non-purpose-built supported housing facilities. The employed methods were thus seen to be able to describe and discriminate between qualities in the physical environment of supported housing facilities. Suggestions for the development of tools for the assessment of the physical environment in supported housing are made.

  17. Retinal Image Quality During Accommodation

    PubMed Central

    López-Gil, N.; Martin, J.; Liu, T.; Bradley, A.; Díaz-Muñoz, D.; Thibos, L.

    2013-01-01

    Purpose We asked if retinal image quality is maximum during accommodation, or sub-optimal due to accommodative error, when subjects perform an acuity task. Methods Subjects viewed a monochromatic (552nm), high-contrast letter target placed at various viewing distances. Wavefront aberrations of the accommodating eye were measured near the endpoint of an acuity staircase paradigm. Refractive state, defined as the optimum target vergence for maximising retinal image quality, was computed by through-focus wavefront analysis to find the power of the virtual correcting lens that maximizes visual Strehl ratio. Results Despite changes in ocular aberrations and pupil size during binocular viewing, retinal image quality and visual acuity typically remain high for all target vergences. When accommodative errors lead to sub-optimal retinal image quality, acuity and measured image quality both decline. However, the effect of accommodation errors of on visual acuity are mitigated by pupillary constriction associated with accommodation and binocular convergence and also to binocular summation of dissimilar retinal image blur. Under monocular viewing conditions some subjects displayed significant accommodative lag that reduced visual performance, an effect that was exacerbated by pharmacological dilation of the pupil. Conclusions Spurious measurement of accommodative error can be avoided when the image quality metric used to determine refractive state is compatible with the focusing criteria used by the visual system to control accommodation. Real focusing errors of the accommodating eye do not necessarily produce a reliably measurable loss of image quality or clinically significant loss of visual performance, probably because of increased depth-of-focus due to pupil constriction. When retinal image quality is close to maximum achievable (given the eye’s higher-order aberrations), acuity is also near maximum. A combination of accommodative lag, reduced image quality, and reduced visual function may be a useful sign for diagnosing functionally-significant accommodative errors indicating the need for therapeutic intervention. PMID:23786386

  18. Retinal image quality during accommodation.

    PubMed

    López-Gil, Norberto; Martin, Jesson; Liu, Tao; Bradley, Arthur; Díaz-Muñoz, David; Thibos, Larry N

    2013-07-01

    We asked if retinal image quality is maximum during accommodation, or sub-optimal due to accommodative error, when subjects perform an acuity task. Subjects viewed a monochromatic (552 nm), high-contrast letter target placed at various viewing distances. Wavefront aberrations of the accommodating eye were measured near the endpoint of an acuity staircase paradigm. Refractive state, defined as the optimum target vergence for maximising retinal image quality, was computed by through-focus wavefront analysis to find the power of the virtual correcting lens that maximizes visual Strehl ratio. Despite changes in ocular aberrations and pupil size during binocular viewing, retinal image quality and visual acuity typically remain high for all target vergences. When accommodative errors lead to sub-optimal retinal image quality, acuity and measured image quality both decline. However, the effect of accommodation errors of on visual acuity are mitigated by pupillary constriction associated with accommodation and binocular convergence and also to binocular summation of dissimilar retinal image blur. Under monocular viewing conditions some subjects displayed significant accommodative lag that reduced visual performance, an effect that was exacerbated by pharmacological dilation of the pupil. Spurious measurement of accommodative error can be avoided when the image quality metric used to determine refractive state is compatible with the focusing criteria used by the visual system to control accommodation. Real focusing errors of the accommodating eye do not necessarily produce a reliably measurable loss of image quality or clinically significant loss of visual performance, probably because of increased depth-of-focus due to pupil constriction. When retinal image quality is close to maximum achievable (given the eye's higher-order aberrations), acuity is also near maximum. A combination of accommodative lag, reduced image quality, and reduced visual function may be a useful sign for diagnosing functionally-significant accommodative errors indicating the need for therapeutic intervention. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  19. Pain and quality of life in Turkish cancer patients.

    PubMed

    Ovayolu, Nimet; Ovayolu, Özlem; Serçe, Sibel; Tuna, Döndü; Pirbudak Çöçelli, Lütfiye; Sevinç, Alper

    2013-12-01

    This study was designed to examine the relationship between patients' pain severity and their self-reported quality of life, to evaluate factors that may affect pain and quality of life, and to assess patients' opinions and practices on the use of analgesics. The study was conducted with 260 cancer patients. Data were collected using a Quality of Life Scale and Visual Analog Scale questionnaire. It was found that mean scores of pain, all subdomains of quality of life, and overall mean scores of patients were at a moderate level, the lowest score in the subdomains of quality of life was in the psychological subdomain and the highest was in the spiritual subdomain. It was also found that as severity of pain experienced by patients increased, their general activities, mood, activeness, sleep, and nutrition were negatively affected. As severity of pain experienced by patients increased, their quality of life worsened. Patients were observed to have insufficient knowledge and a poor understanding with respect to the use of analgesics. In conclusion, it is very important for nurses to assess factors that can complicate pain management and to establish an effective pain control. © 2013 Wiley Publishing Asia Pty Ltd.

  20. Evaluating the effect of a third-party implementation of resolution recovery on the quality of SPECT bone scan imaging using visual grading regression.

    PubMed

    Hay, Peter D; Smith, Julie; O'Connor, Richard A

    2016-02-01

    The aim of this study was to evaluate the benefits to SPECT bone scan image quality when applying resolution recovery (RR) during image reconstruction using software provided by a third-party supplier. Bone SPECT data from 90 clinical studies were reconstructed retrospectively using software supplied independent of the gamma camera manufacturer. The current clinical datasets contain 120×10 s projections and are reconstructed using an iterative method with a Butterworth postfilter. Five further reconstructions were created with the following characteristics: 10 s projections with a Butterworth postfilter (to assess intraobserver variation); 10 s projections with a Gaussian postfilter with and without RR; and 5 s projections with a Gaussian postfilter with and without RR. Two expert observers were asked to rate image quality on a five-point scale relative to our current clinical reconstruction. Datasets were anonymized and presented in random order. The benefits of RR on image scores were evaluated using ordinal logistic regression (visual grading regression). The application of RR during reconstruction increased the probability of both observers of scoring image quality as better than the current clinical reconstruction even where the dataset contained half the normal counts. Type of reconstruction and observer were both statistically significant variables in the ordinal logistic regression model. Visual grading regression was found to be a useful method for validating the local introduction of technological developments in nuclear medicine imaging. RR, as implemented by the independent software supplier, improved bone SPECT image quality when applied during image reconstruction. In the majority of clinical cases, acquisition times for bone SPECT intended for the purposes of localization can safely be halved (from 10 s projections to 5 s) when RR is applied.

  1. Surface mine planning and design implications and theory of a visual environmental quality predictive model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burley, J.B.

    1999-07-01

    Surface mine planners and designers are searching for scientifically based tools to assist in the pre-mine planning and post-mine development or surface mine sites. In this study, the author presents a science based visual and environmental quality predictive model useful in preparing and assessing landscape treatments for surface mine sites. The equation explains 67 percent of respondent preference, with an overall p-value for the equation >0.0001 and a p-value >0.05 for each regressor. Regressors employed in the equation include an environmental quality index, foreground vegetation, distant nonvegetation, people, vehicles, utilities, foreground flowers, foreground erosion, wildlife, landscape openness, landscape mystery, andmore » noosphericness (a measure of human disturbance). The equation can be explained with an Intrusion/Neutral Modifier/Temporal Enhancement Theory which suggests that human intrusions upon other humans results in landscape of low preference and which also suggests that landscape containing natural and special temporal features such as wildlife and flowers can enhance the value of a landscape scene. This research supports the importance of visual barriers such as berms and vegetation screens during mining operations and supports public perceptions concerning many types of industrial activities. In addition, the equation can be applied to study post-mining landscape development plans to maximize the efficiency and effectiveness of landscape treatments.« less

  2. Quantifying the visual-sensory landscape qualities that contribute to cultural ecosystem services using social media and LiDAR

    USGS Publications Warehouse

    Van Berkel, Derek B.; Tabrizian, Payam; Dorning, Monica; Smart, Lindsey S.; Newcomb, Doug; Mehaffey, Megan; Neale, Anne; Meentemeyer, Ross K.

    2018-01-01

    Landscapes are increasingly recognized for providing valuable cultural ecosystem services with numer- ous non-material benefits by serving as places of rest, relaxation, and inspiration that ultimately improve overall mental health and physical well-being. Maintaining and enhancing these valuable benefits through targeted management and conservation measures requires understanding the spatial and tem- poral determinants of perceived landscape values. Content contributed through mobile technologies and the web are emerging globally, providing a promising data source for localizing and assessing these land- scape benefits. These georeferenced data offer rich in situ qualitative information through photos and comments that capture valued and special locations across large geographic areas. We present a novel method for mapping and modeling landscape values and perceptions that leverages viewshed analysis of georeferenced social media data. Using a high resolution LiDAR (Light Detection and Ranging) derived digital surface model, we are able to evaluate landscape characteristics associated with the visual- sensory qualities of outdoor recreationalists. Our results show the importance of historical monuments and attractions in addition to specific environmental features which are appreciated by the public. Evaluation of photo-image content highlights the opportunity of including temporally and spatially vari- able visual-sensory qualities in cultural ecosystem services (CES) evaluation like the sights, sounds and smells of wildlife and weather phenomena.

  3. The Nencki Affective Picture System (NAPS): introduction to a novel, standardized, wide-range, high-quality, realistic picture database.

    PubMed

    Marchewka, Artur; Zurawski, Łukasz; Jednoróg, Katarzyna; Grabowska, Anna

    2014-06-01

    Selecting appropriate stimuli to induce emotional states is essential in affective research. Only a few standardized affective stimulus databases have been created for auditory, language, and visual materials. Numerous studies have extensively employed these databases using both behavioral and neuroimaging methods. However, some limitations of the existing databases have recently been reported, including limited numbers of stimuli in specific categories or poor picture quality of the visual stimuli. In the present article, we introduce the Nencki Affective Picture System (NAPS), which consists of 1,356 realistic, high-quality photographs that are divided into five categories (people, faces, animals, objects, and landscapes). Affective ratings were collected from 204 mostly European participants. The pictures were rated according to the valence, arousal, and approach-avoidance dimensions using computerized bipolar semantic slider scales. Normative ratings for the categories are presented for each dimension. Validation of the ratings was obtained by comparing them to ratings generated using the Self-Assessment Manikin and the International Affective Picture System. In addition, the physical properties of the photographs are reported, including luminance, contrast, and entropy. The new database, with accompanying ratings and image parameters, allows researchers to select a variety of visual stimulus materials specific to their experimental questions of interest. The NAPS system is freely accessible to the scientific community for noncommercial use by request at http://naps.nencki.gov.pl .

  4. Using visual processing training to enhance standard cognitive remediation outcomes in schizophrenia: A pilot study.

    PubMed

    Contreras, Natalia A; Tan, Eric J; Lee, Stuart J; Castle, David J; Rossell, Susan L

    2018-04-01

    Approaches to cognitive remediation (CR) that address sensory perceptual skills before higher cognitive skills, have been found to be effective in enhancing cognitive performance in schizophrenia. To date, however, most of the conducted trials have concentrated on auditory processing. The aim of this study was to explore whether the addition of visual processing training could enhance standard cognitive remediation outcomes in a schizophrenia population. Twenty participants were randomised to either receive 20h of computer-assisted cognitive remediation alone or 20h of visual processing training modules and cognitive remediation training. All participants were assessed at baseline and at the end of cognitive remediation training on cognitive and psychosocial (i.e. self-esteem, quality of life) measures. At the end of the study participants across both groups improved significantly in overall cognition and psychosocial functioning. No significant differences were observed between groups on any of the measures. Of potential interest, however, was that the Cohen's d assessing the between group difference in the rates of change were moderate/large for a greater improvement in Visual Learning, Working Memory and Social Cognition for the visual training plus cognitive remediation group. On the basis of our effect sizes on three domains of cognition, we recommend replicating this intervention with a larger sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. 76 FR 22882 - Draft National Pollutant Discharge Elimination System (NPDES) General Permit for Stormwater...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ... know your identity or contact information unless you provide it in the body of your comment. If you... include your name and other contact information in the body of your comment and with any disk or CD-ROM... visually assess the quality of the discharge (e.g., color, odor, floating, settled, or suspended solids) if...

  6. Quantifying clutter: A comparison of four methods and their relationship to bat detection

    Treesearch

    Joy M. O’Keefe; Susan C. Loeb; Hoke S. Hill Jr.; J. Drew Lanham

    2014-01-01

    The degree of spatial complexity in the environment, or clutter, affects the quality of foraging habitats for bats and their detection with acoustic systems. Clutter has been assessed in a variety of ways but there are no standardized methods for measuring clutter. We compared four methods (Visual Clutter, Cluster, Single Variable, and Clutter Index) and related these...

  7. An Analysis of the Units "I'm Learning My Past" and "The Place Where We Live" in the Social Studies Textbook Related to Critical Thinking Standards

    ERIC Educational Resources Information Center

    Aybek, Birsel; Aslan, Serkan

    2016-01-01

    Problem Statement: Various research have been conducted investigating the quality and quantity of textbooks such as wording, content, design, visuality, physical properties, activities, methods and techniques, questions and experiments, events, misconceptions, organizations, pictures, text selection, end of unit questions and assessments, indexes…

  8. An assessment of differential reinforcement procedures for learners with autism spectrum disorder.

    PubMed

    Johnson, Kate A; Vladescu, Jason C; Kodak, Tiffany; Sidener, Tina M

    2017-04-01

    Differential reinforcement procedures may promote unprompted correct responding, resulting in a quicker transfer of stimulus control than nondifferential reinforcement. Recent studies that have compared reinforcement arrangements have found that the most effective arrangement may differ across participants. The current study conducted an assessment of differential reinforcement arrangements (i.e., quality, schedule, and magnitude) and nondifferential reinforcement to identify the most effective arrangement for each participant. The assessment phase showed that the quality arrangement was the most efficient for all participants during auditory-visual matching. Next, a validation phase was conducted to evaluate whether the assessment would predict the most effective arrangement across multiple skills. The results from the assessment phase were validated for all participants for the same skill. However, the results were only validated for one participant during the other skills (i.e., tact and intraverbal). The results are discussed in light of previous research and future areas of research. © 2017 Society for the Experimental Analysis of Behavior.

  9. Effect of baby oil on pruritus, sleep quality, and quality of life in hemodialysis patients: pretest-post-test model with control groups.

    PubMed

    Karadag, Ezgi; Kilic, Serap Parlar; Karatay, Gülnaz; Metin, Ozgur

    2014-07-01

    To assess the effect of baby oil on pruritus, sleep quality, and quality of life in hemodialysis (HD) patients. This pretest-post-test model with control groups study was conducted in HD units in two different provinces in eastern Turkey. The study group consisted of a total of 70 patients receiving HD treatment who met the inclusion criteria, 35 being in the intervention group and 35 in the control group. After the patients in both groups were informed about the study, they were administered a questionnaire, the Severity Scale, Visual Analog Scale, the Pittsburgh Sleep Quality Index, and the SF-36 Quality of Life Scale. Following the administration of baby oil to the patients in the intervention group three times a week for a period of 1 month, the same scales were repeated to explore their pruritic status, sleep quality, and quality of life. The same scales were repeated also for the patients in the control group 1 month later but without administering any baby oil. When the Itch Severity Scale, Visual Analog Scale, Pittsburgh Sleep Quality Index, and SF-36 Quality of Life Physical and Mental Component scores of the patients in the control and intervention groups before and after the intervention were compared, the differences in the change were found to be statistically significant in favor of the intervention group (P < 0.05). It was found in this study that administration of baby oil had positive effects on itching, quality of life, and sleep quality in HD patients who had itching complaints. © 2013 The Authors. Japan Journal of Nursing Science © 2013 Japan Academy of Nursing Science.

  10. Visualizing the Quality of Vectur Features - a Proposal for Cadastral Maps

    NASA Astrophysics Data System (ADS)

    Navratil, G.; Leopoldseder, V.

    2017-09-01

    A well-known problem of geographical information is the communication of the quality level. It can be either done verbally / numerically or it can be done graphically. The graphical form is especially useful if the quality has a spatial variation because the spatial distribution is visualized as well. The problem of spatial variation of quality is an issue for cadastral maps. Non-experts cannot determine the quality at a specific location. Therefore a visual representation was tested for the Austrian cadastre. A map sheet was redesigned to give some indication of cadastral quality and presented to both experts and non-experts. The paper presents the result of the interviews.

  11. Designing and Validation a Visual Fatigue Questionnaire for Video Display Terminals Operators

    PubMed Central

    Rajabi-Vardanjani, Hassan; Habibi, Ehsanollah; Pourabdian, Siyamak; Dehghan, Habibollah; Maracy, Mohammad Reza

    2014-01-01

    Background: Along with the rapid growth of technology its related tools such as computer, monitors and video display terminals (VDTs) grow as well. Based on the studies, the most common complaint reported is of the VDT users. Methods: This study attempts to design a proper tool to assess the visual fatigue of the VDT users. First draft of the questionnaire was prepared after a thorough study on the books, papers and similar questionnaires. The validity and reliability of the questionnaire was confirmed using the content validity index (CVI) beside that of the Cronbach's Coefficient Alpha. Then, a cross-sectional study was carried out on 248 of the VDT users in different professions. A theoretical model with four categories of symptoms of visual fatigue was derived from the previous studies and questionnaires. Having used the AMOS16 software, the construct validity of the questionnaire was evaluated using the confirmatory factor analysis. The correlation co-efficiency of the internal domains was calculated using the SPSS 11.5 software. To assess the quality check index and determining the visual fatigue levels, visual fatigue of the VDT users was measured by the questionnaire and visual fatigue meter (VFM) device. Cut-off points were identified by receiver operating characteristic curves. Results: CVI and reliability co-efficiency were both equal to 0.75. Model fit indices including root mean of squared error approximation, goodness of fit index and adjusted goodness of fit index were obtained 0.026, 0.96 and 0.92 respectfully. The correlation between the results measured with the questionnaire and VFM-90.1 device was −0.87. Cut-off points of the questionnaire were 0.65, 2.36 and 3.88. The confirmed questionnaire consists of four main areas: Eye strain (4 questions), visual impairment (5 questions) and the surface impairment of the eye (3 questions) and the out of eye problems (3 questions). Conclusions: The visual fatigue questionnaire contains 15 questions and has a very remarkable validity and reliability. Using this questionnaire and its findings, one will be able to identify, assess and finally prevent the effective factors of VDT users’ visual fatigue. PMID:25104995

  12. Rice Grain Quality and Consumer Preferences: A Case Study of Two Rural Towns in the Philippines

    PubMed Central

    Velarde, Orlee; Demont, Matty

    2016-01-01

    Hedonic pricing analysis is conducted to determine the implicit values of various attributes in the market value of a good. In this study, hedonic pricing analysis was applied to measure the contribution of grain quality search and experience attributes to the price of rice in two rural towns in the Philippines. Rice samples from respondents underwent quantitative routine assessments of grain quality. In particular, gelatinization temperature and chalkiness, two parameters that are normally assessed through visual scores, were evaluated by purely quantitative means (differential scanning calorimetry and by digital image analysis). Results indicate that rice consumed by respondents had mainly similar physical and chemical grain quality attributes. The respondents’ revealed preferences were typical of what has been previously reported for Filipino rice consumers. Hedonic regression analyses showed that grain quality characteristics that affected price varied by income class. Some of the traits or socioeconomic factors that affected price were percent broken grains, gel consistency, and household per capita rice consumption. There is an income effect on rice price and the characteristics that affect price vary between income classes. PMID:26982587

  13. Rice Grain Quality and Consumer Preferences: A Case Study of Two Rural Towns in the Philippines.

    PubMed

    Cuevas, Rosa Paula; Pede, Valerien O; McKinley, Justin; Velarde, Orlee; Demont, Matty

    2016-01-01

    Hedonic pricing analysis is conducted to determine the implicit values of various attributes in the market value of a good. In this study, hedonic pricing analysis was applied to measure the contribution of grain quality search and experience attributes to the price of rice in two rural towns in the Philippines. Rice samples from respondents underwent quantitative routine assessments of grain quality. In particular, gelatinization temperature and chalkiness, two parameters that are normally assessed through visual scores, were evaluated by purely quantitative means (differential scanning calorimetry and by digital image analysis). Results indicate that rice consumed by respondents had mainly similar physical and chemical grain quality attributes. The respondents' revealed preferences were typical of what has been previously reported for Filipino rice consumers. Hedonic regression analyses showed that grain quality characteristics that affected price varied by income class. Some of the traits or socioeconomic factors that affected price were percent broken grains, gel consistency, and household per capita rice consumption. There is an income effect on rice price and the characteristics that affect price vary between income classes.

  14. Objective quality assessment of tone-mapped images.

    PubMed

    Yeganeh, Hojatollah; Wang, Zhou

    2013-02-01

    Tone-mapping operators (TMOs) that convert high dynamic range (HDR) to low dynamic range (LDR) images provide practically useful tools for the visualization of HDR images on standard LDR displays. Different TMOs create different tone-mapped images, and a natural question is which one has the best quality. Without an appropriate quality measure, different TMOs cannot be compared, and further improvement is directionless. Subjective rating may be a reliable evaluation method, but it is expensive and time consuming, and more importantly, is difficult to be embedded into optimization frameworks. Here we propose an objective quality assessment algorithm for tone-mapped images by combining: 1) a multiscale signal fidelity measure on the basis of a modified structural similarity index and 2) a naturalness measure on the basis of intensity statistics of natural images. Validations using independent subject-rated image databases show good correlations between subjective ranking score and the proposed tone-mapped image quality index (TMQI). Furthermore, we demonstrate the extended applications of TMQI using two examples-parameter tuning for TMOs and adaptive fusion of multiple tone-mapped images.

  15. Validation of a Spectral Method for Quantitative Measurement of Color in Protein Drug Solutions.

    PubMed

    Yin, Jian; Swartz, Trevor E; Zhang, Jian; Patapoff, Thomas W; Chen, Bartolo; Marhoul, Joseph; Shih, Norman; Kabakoff, Bruce; Rahimi, Kimia

    2016-01-01

    A quantitative spectral method has been developed to precisely measure the color of protein solutions. In this method, a spectrophotometer is utilized for capturing the visible absorption spectrum of a protein solution, which can then be converted to color values (L*a*b*) that represent human perception of color in a quantitative three-dimensional space. These quantitative values (L*a*b*) allow for calculating the best match of a sample's color to a European Pharmacopoeia reference color solution. In order to qualify this instrument and assay for use in clinical quality control, a technical assessment was conducted to evaluate the assay suitability and precision. Setting acceptance criteria for this study required development and implementation of a unique statistical method for assessing precision in 3-dimensional space. Different instruments, cuvettes, protein solutions, and analysts were compared in this study. The instrument accuracy, repeatability, and assay precision were determined. The instrument and assay are found suitable for use in assessing color of drug substances and drug products and is comparable to the current European Pharmacopoeia visual assessment method. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. In this study, we established a statistical method for assessing precision in 3-dimensional space and demonstrated that the quantitative spectral method is comparable with respect to precision and accuracy to the current European Pharmacopoeia visual assessment method. © PDA, Inc. 2016.

  16. The predictive value of aptitude assessment in laparoscopic surgery: a meta-analysis.

    PubMed

    Kramp, Kelvin H; van Det, Marc J; Hoff, Christiaan; Veeger, Nic J G M; ten Cate Hoedemaker, Henk O; Pierie, Jean-Pierre E N

    2016-04-01

    Current methods of assessing candidates for medical specialties that involve laparoscopic skills suffer from a lack of instruments to assess the ability to work in a minimally invasive surgery environment. A meta-analysis was conducted to investigate whether aptitude assessment can be used to predict variability in the acquisition and performance of laparoscopic skills. PubMed, PsycINFO and Google Scholar were searched to November 2014 for published and unpublished studies reporting the measurement of a form of aptitude for laparoscopic skills. The quality of studies was assessed with QUADAS-2. Summary correlations were calculated using a random-effects model. Thirty-four studies were found to be eligible for inclusion; six of these studies used an operating room performance measurement. Laparoscopic skills correlated significantly with visual-spatial ability (r = 0.32, 95% confidence interval [CI] 0.25-0.39; p < 0.001), perceptual ability (r = 0.31, 95% CI 0.22-0.39; p < 0.001), psychomotor ability (r = 0.26, 95% CI 0.10-0.40; p = 0.003) and simulator-based assessment of aptitude (r = 0.64, 95% CI 0.52-0.73; p < 0.001). Three-dimensional dynamic visual-spatial ability showed a significantly higher correlation than intrinsic static visual-spatial ability (p = 0.024). In general, aptitude assessments are associated with laparoscopic skill level. Simulator-based assessment of aptitude appears to have the potential to represent a job sample and to enable the assessment of all forms of aptitude for laparoscopic surgery at once. A laparoscopy aptitude test can be a valuable additional tool in the assessment of candidates for medical specialties that require laparoscopic skills. © 2016 John Wiley & Sons Ltd.

  17. Assessment of pupillary influence in LASIK patients using a digital pupillometer and VQF 25 questionnaire.

    PubMed

    Andrade, Eduardo Marcelo Moron de; Chamon, Wallace

    2013-10-01

    Identify ideal profiles in patients undergoing to photorefractive laser surgery with the aid of an automated pupillometry and psychometric analysis of patients with visual function questionnaire (VQF 25). Seventy-seven patients undergoing photorefractive laser surgery laser (LASIK) were analyzed with the aid of an automated digital pupillometer based on an infrared camera coupled to the optical head of a videokeratography system. Patients underwent complete ophthalmic evaluation and documentation of the pupillary behavior under different intensities of illumination, simulating situations of everyday life. Visual quality function questionnaire, translated to Portuguese was assessed. All patients, regardless of pupillary change under varying conditions of illumination (scotopic, mesopic and photopic) showed improvement in all sub-groups of the VQF 25. Pupil diameter was not the primary determinant of patients' visual satisfaction. Despite digital pupillometer has proven to be a useful tool in documenting and understanding of pupil behavior, a set of factors such as psycho-social profile, preoperative ametropy and final residual ametropy, contributed decisively to determine the degree of satisfaction of patients undergoing LASIK.

  18. Visual acuity estimation from simulated images

    NASA Astrophysics Data System (ADS)

    Duncan, William J.

    Simulated images can provide insight into the performance of optical systems, especially those with complicated features. Many modern solutions for presbyopia and cataracts feature sophisticated power geometries or diffractive elements. Some intraocular lenses (IOLs) arrive at multifocality through the use of a diffractive surface and multifocal contact lenses have a radially varying power profile. These type of elements induce simultaneous vision as well as affecting vision much differently than a monofocal ophthalmic appliance. With myriad multifocal ophthalmics available on the market it is difficult to compare or assess performance in ways that effect wearers of such appliances. Here we present software and algorithmic metrics that can be used to qualitatively and quantitatively compare ophthalmic element performance, with specific examples of bifocal intraocular lenses (IOLs) and multifocal contact lenses. We anticipate this study, methods, and results to serve as a starting point for more complex models of vision and visual acuity in a setting where modeling is advantageous. Generating simulated images of real- scene scenarios is useful for patients in assessing vision quality with a certain appliance. Visual acuity estimation can serve as an important tool for manufacturing and design of ophthalmic appliances.

  19. Assessment of Visual Reliance in Balance Control: An Inexpensive Extension of the Static Posturography.

    PubMed

    Púčik, Jozef; Šaling, Marián; Lukáč, Tomáš; Ondráček, Oldřich; Kucharík, Martin

    2014-01-01

    Ability of humans to maintain balance in an upright stance and during movement activities is one of the most natural skills affecting everyday life. This ability progressively deteriorates with increasing age, and balance impairment, often aggravated by age-related diseases, can result in falls that adversely impact the quality of life. Falls represent serious problems of health concern associated with aging. Many investigators, involved in different science disciplines such as medicine, engineering, psychology, and sport, have been attracted by a research of the human upright stance. In a clinical practice, stabilometry based on the force plate is the most widely available procedure used to evaluate the balance. In this paper, we have proposed a low-cost extension of the conventional stabilometry by the multimedia technology that allows identifying potentially disturbing effects of visual sensory information. Due to the proposed extension, a stabilometric assessment in terms of line integral of center of pressure (COP) during moving scene stimuli shows higher discrimination power between young healthy and elderly subjects with supposed stronger visual reliance.

  20. Assessment of Visual Reliance in Balance Control: An Inexpensive Extension of the Static Posturography

    PubMed Central

    Púčik, Jozef; Šaling, Marián; Lukáč, Tomáš; Ondráček, Oldřich; Kucharík, Martin

    2014-01-01

    Ability of humans to maintain balance in an upright stance and during movement activities is one of the most natural skills affecting everyday life. This ability progressively deteriorates with increasing age, and balance impairment, often aggravated by age-related diseases, can result in falls that adversely impact the quality of life. Falls represent serious problems of health concern associated with aging. Many investigators, involved in different science disciplines such as medicine, engineering, psychology, and sport, have been attracted by a research of the human upright stance. In a clinical practice, stabilometry based on the force plate is the most widely available procedure used to evaluate the balance. In this paper, we have proposed a low-cost extension of the conventional stabilometry by the multimedia technology that allows identifying potentially disturbing effects of visual sensory information. Due to the proposed extension, a stabilometric assessment in terms of line integral of center of pressure (COP) during moving scene stimuli shows higher discrimination power between young healthy and elderly subjects with supposed stronger visual reliance. PMID:27006930

  1. Disease activity, quality of life and indirect costs of reduced productivity at work, generated by Polish patients with ankylosing spondylitis.

    PubMed

    Kawalec, Paweł; Malinowski, Krzysztof

    2015-01-01

    The aim of the study was to investigate the association between activity of ankylosing spondylitis (AS) and decrease in quality of life as well as productivity loss of affected patients in a specified group of patients in the Polish setting. An questionnaire survey was conducted using the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) to assess disease activity, as well as the Work Productivity and Activity Impairment Questionnaires to assess productivity loss; quality of life was presented as utility calculated using the EuroQol 5 questionnaire and also measured on a visual analogue scale (VAS). Indirect costs were assessed with the human capital approach implying gross domestic product per capita or gross value added per worker in Poland in 2014 and were expressed in Polish zlotys (PLN) as well as in euros. Correlation was presented using Spearman's rank correlation coefficient. We performed our analysis based on 78 full questionnaires collected. A mean BASDAI score of 5.91 in the analysed group of patients was detected and mean utility of 0.5135 was observed. Average quality of life measured on the visual analogue scale was 46.55. Mean number of days off work was 45.26 days per year and mean on-the-job productivity loss was 49.29%. Average annual indirect costs per patient were €4241 (17 686 PLN) calculated using gross domestic product and €10 172 (42 417 PLN) estimated using gross value added. Total productivity loss was significantly correlated with disease activity (strong correlation of 0.6005) and utility (moderate correlation of -0.3698). Ankylosing spondylitis causes a great decrease in quality of life as well as patients' productivity loss associated with both absenteeism and presenteeism. The greater the disease activity is, the lower is the utility, the lower is the quality of life measured on the VAS, and the greater are the total annual indirect costs. Total indirect costs were negatively correlated with utility; although the association was moderate, it was significant.

  2. Fuels planning: science synthesis and integration; social issues fact sheet 16: Prescribed fire and visual quality

    Treesearch

    Christine Esposito

    2006-01-01

    Research shows that, while prescribed burning and other fuels treatments can lower visual quality in some situations, they can also improve it in others. This fact sheet reviews the visual aspects of different levels of prescribed burning.Other publications in this series...

  3. Technology-Enhanced Learning in Science (TELS)

    NASA Astrophysics Data System (ADS)

    Linn, Marcia

    2006-12-01

    The overall research question addressed by the NSF-funded echnologyEnhanced Learning in Science (TELS) Center is whether interactive scientific visualizations embedded in high quality instructional units can be used to increase pre-college student learning in science. The research draws on the knowledge integration framework to guide the design of instructional modules, professional development activities, and assessment activities. This talk reports on results from the first year where 50 teachers taught one of the 12 TELS modules in over 200 classes in 16 diverse schools. Assessments scored with the knowledge integration rubric showed that students made progress in learning complex physics topics such as electricity, mechanics, and thermodynamics. Teachers encountered primarily technological obstacles that the research team was able to address prior to implementation. Powerful scientific visualizations required extensive instructional supports to communicate to students. Currently, TELS is refining the modules, professional development, and assessments based on evidence from the first year. Preliminary design principles intended to help research teams build on the findings will be presented for audience feedback and discussion.

  4. BIDDSAT: visualizing the content of biodiversity data publishers in the Global Biodiversity Information Facility network.

    PubMed

    Otegui, Javier; Ariño, Arturo H

    2012-08-15

    In any data quality workflow, data publishers must become aware of issues in their data so these can be corrected. User feedback mechanisms provide one avenue, while global assessments of datasets provide another. To date, there is no publicly available tool to allow both biodiversity data institutions sharing their data through the Global Biodiversity Information Facility network and its potential users to assess datasets as a whole. Contributing to bridge this gap both for publishers and users, we introduce BIoDiversity DataSets Assessment Tool, an online tool that enables selected diagnostic visualizations on the content of data publishers and/or their individual collections. The online application is accessible at http://www.unav.es/unzyec/mzna/biddsat/ and is supported by all major browsers. The source code is licensed under the GNU GPLv3 license (http://www.gnu.org/licenses/gpl-3.0.txt) and is available at https://github.com/jotegui/BIDDSAT.

  5. Prisms to Shift Pain Away: Pathophysiological and Therapeutic Exploration of CRPS with Prism Adaptation.

    PubMed

    Christophe, Laure; Chabanat, Eric; Delporte, Ludovic; Revol, Patrice; Volckmann, Pierre; Jacquin-Courtois, Sophie; Rossetti, Yves

    Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations.

  6. The effects of auditive and visual settings on perceived restoration likelihood

    PubMed Central

    Jahncke, Helena; Eriksson, Karolina; Naula, Sanna

    2015-01-01

    Research has so far paid little attention to how environmental sounds might affect restorative processes. The aim of the present study was to investigate the effects of auditive and visual stimuli on perceived restoration likelihood and attitudes towards varying environmental resting conditions. Assuming a condition of cognitive fatigue, all participants (N = 40) were presented with images of an open plan office and urban nature, each under four sound conditions (nature sound, quiet, broadband noise, office noise). After the presentation of each setting/sound combination, the participants assessed it according to restorative qualities, restoration likelihood and attitude. The results mainly showed predicted effects of the sound manipulations on the perceived restorative qualities of the settings. Further, significant interactions between auditive and visual stimuli were found for all measures. Both nature sounds and quiet more positively influenced evaluations of the nature setting compared to the office setting. When office noise was present, both settings received poor evaluations. The results agree with expectations that nature sounds and quiet areas support restoration, while office noise and broadband noise (e.g. ventilation, traffic noise) do not. The findings illustrate the significance of environmental sound for restorative experience. PMID:25599752

  7. [Disease perception in patients with wet age-related macular degeneration].

    PubMed

    Kostadinov, F; Valmaggia, C

    2015-04-01

    The disease perception of the patients treated with intravitreal injections of anti-vascular endothelial growth factor due to wet age-related macular degeneration was investigated. 177 questionnaires focusing on the development of the perceived visual acuity and the quality of life were evaluated. The subgroup 1 included 125 patients (70.6%) with a unilateral wet age-related macular degeneration. The subgroup 2 included 52 patients (29.4%) with a bilateral wet age-related macular degeneration. Patients would almost always recommend the therapy to a friend (97.2%). The critical remarks are related to the uncertain course of the disease (22.8%) and the uncertain duration of the treatment (19%). There was a discrepancy between the measured visual outcome and the perceived one in 5.6% in the subgroup 1, and in 38.5% in the subgroup 2. This difference was statistically significant (chi-square test with p<0.01). The treatment of wet age-related macular degeneration with intravitreal injections of anti-vascular endothelial growth factor is judged positively. Binocular affected patients have a higher disease perception and therefore a poorer self-assessment of their visual acuity and their quality of life compared with monocular affected patients. Georg Thieme Verlag KG Stuttgart · New York.

  8. Single-site Baseline and Short-term Outcomes of Clinical Characteristics and Life Quality Evaluation of Chinese Wet Age-related Macular Degeneration Patients in Routine Clinical Practice

    PubMed Central

    Wang, Li-Li; Liu, Wen-Jia; Liu, Hai-Yun; Xu, Xun

    2015-01-01

    Background: Age-related macular degeneration (AMD) is the leading cause of irreversible vision loss among the older population. In China, treatment of age-related ocular diseases is becoming a priority in eye care services. This study was to investigate the clinical characteristics and quality of life of Chinese patients with wet AMD and current treatment types, to evaluate short-term gains in different treatments, and to investigate associations between visual function and vision-related quality of life (VRQoL). Methods: A prospective, observational, noninterventional study was conducted. Basic data were collected from patients with clinical diagnoses of wet AMD before clinical assessments at baseline. VRQoL was measured with the Chinese version of the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). Correlations of the NEI VFQ-25 subscale scores with best-corrected visual acuity (BCVA) and between-group differences were analyzed. Results: A total of 80 wet AMD patients were enrolled, with the mean age of 68.40 years. About one-quarter of wet AMD patients received intravitreal (IVT) ranibizumab treatment, and 67% of them were treated on a pro re nata basis. The visual acuity of patients treated with IVT ranibizumab at month 3 after treatment was significantly increased, whereas patients treated with traditional Chinese medicine achieved no significant improvement. Cronbach's α for the NEI VFQ-25 subscales ranged from 0.697 to 0.843. Eight subscale and overall composite scores were moderately correlated with the BCVA of the better-seeing eye. Significant differences in the overall NEI VFQ-25 scores and other subscales were observed between patients with BCVA in the better-seeing eye of less than 50 letters and the others. Conclusions: Patients treated with IVT ranibizumab experienced better vision improvement at short-term follow-up. The Chinese version of the NEI VFQ-25 is a valid and reliable tool for assessing the VRQoL of Chinese wet AMD patients. PMID:25947396

  9. [Health Risk Assessment of Drinking Water Quality in Tianjin Based on GIS].

    PubMed

    Fu, Gang; Zeng, Qiang; Zhao, Liang; Zhang, Yue; Feng, Bao-jia; Wang, Rui; Zhang, Lei; Wang, Yang; Hou, Chang-chun

    2015-12-01

    This study intends to assess the potential health hazards of drinking water quality and explore the application of geographic information system( GIS) in drinking water safety in Tianjin. Eight hundred and fifty water samples from 401 sampling points in Tianjin were measured according to the national drinking water standards. The risk assessment was conducted using the environmental health risk assessment model recommended by US EAP, and GIS was combined to explore the information visualization and risk factors simultaneously. The results showed that the health risks of carcinogens, non-carcinogens were 3.83 x 10⁻⁵, 5.62 x 10⁻⁹ and 3.83 x 10⁻⁵ for total health risk respectively. The rank of health risk was carcinogen > non-carcinogen. The rank of carcinogens health risk was urban > new area > rural area, chromium (VI) > cadmium > arsenic > trichlormethane > carbon tetrachloride. The rank of non-carcinogens health risk was rural area > new area > urban, fluoride > cyanide > lead > nitrate. The total health risk level of drinking water in Tianjin was lower than that of ICRP recommended level (5.0 x 10⁻⁵), while was between US EPA recommended level (1.0 x 10⁻⁴-1.0 x 10⁻⁶). It was at an acceptable level and would not cause obvious health hazards. The main health risks of drinking water came from carcinogens. More attentions should be paid to chromium (VI) for carcinogens and fluoride for non-carcinogens. GIS can accomplish information visualization of drinking water risk assessment and further explore of risk factors.

  10. Voice Use Among Music Theory Teachers: A Voice Dosimetry and Self-Assessment Study.

    PubMed

    Schiller, Isabel S; Morsomme, Dominique; Remacle, Angélique

    2017-07-25

    This study aimed (1) to investigate music theory teachers' professional and extra-professional vocal loading and background noise exposure, (2) to determine the correlation between vocal loading and background noise, and (3) to determine the correlation between vocal loading and self-evaluation data. Using voice dosimetry, 13 music theory teachers were monitored for one workweek. The parameters analyzed were voice sound pressure level (SPL), fundamental frequency (F0), phonation time, vocal loading index (VLI), and noise SPL. Spearman correlation was used to correlate vocal loading parameters (voice SPL, F0, and phonation time) and noise SPL. Each day, the subjects self-assessed their voice using visual analog scales. VLI and self-evaluation data were correlated using Spearman correlation. Vocal loading parameters and noise SPL were significantly higher in the professional than in the extra-professional environment. Voice SPL, phonation time, and female subjects' F0 correlated positively with noise SPL. VLI correlated with self-assessed voice quality, vocal fatigue, and amount of singing and speaking voice produced. Teaching music theory is a profession with high vocal demands. More background noise is associated with increased vocal loading and may indirectly increase the risk for voice disorders. Correlations between VLI and self-assessments suggest that these teachers are well aware of their vocal demands and feel their effect on voice quality and vocal fatigue. Visual analog scales seem to represent a useful tool for subjective vocal loading assessment and associated symptoms in these professional voice users. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Reliability and Validity of the Turkish Adaptation of VITACORA-19 in Patients with Psoriatic Arthritis.

    PubMed

    Tander, Berna; Ulus, Yasemin; Terzi, Yüksel; Zahiroğlu, Yeliz; Kesmen, Hakan; Farisoğullari, Bayram; Akyol, Yeşim; Bilgici, Ayhan; Kuru, Ömer

    2016-12-01

    This study aims to evaluate the reliability and validity of the Turkish language version of VITACORA-19 (psoriatic arthritis quality of life questionnaire) in patients with psoriatic arthritis. The Turkish version of VITACORA-19 questionnaire was obtained after a translation and back translation process. The study sample included 61 PsA patients (22 males, 39 females; mean age 46.5±12.2 years; range 19 to 71 years). To assess the test-retest reliability of the Turkish VITACORA-19, the questionnaire was reapplied 10 to 15 days after the first interview (interclass correlation coefficient). Cronbach's alpha (a) was used to evaluate the internal consistency. VITACORA-19 was compared with visual analog scale for physician and patient global assessments, the Health Assessment Questionnaire, and Nottingham Health Profile for construct validity. The internal structure of VITACORA-19 was examined by factor analysis. The individual item intraclass correlation coefficient ranged from 0.77 to 0.98 and Cronbach's alpha ranged from 0.77 to 0.98. The Cronbach's alpha value for whole scale was determined as 0.96. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.90, and Bartlett's test of sphericity had a p<0.001. Turkish VITACORA-19 total scores were correlated negatively with Health Assessment Questionnaire, visual analog scale for pain, and Nottingham Health Profile subgroups, and positively with physician and patient global assessments (p<0.01). Turkish version of VITACORA-19 questionnaire is a reliable and valid measure for health-related quality of life in Turkish patients with psoriatic arthritis.

  12. Reliability and Validity of the Turkish Adaptation of VITACORA-19 in Patients with Psoriatic Arthritis

    PubMed Central

    ULUS, Yasemin; TERZİ, Yüksel; ZAHİROĞLU, Yeliz; KESMEN, Hakan; FARİSOĞULLARI, Bayram; AKYOL, Yeşim; BİLGİCİ, Ayhan; KURU, Ömer

    2016-01-01

    Objectives This study aims to evaluate the reliability and validity of the Turkish language version of VITACORA-19 (psoriatic arthritis quality of life questionnaire) in patients with psoriatic arthritis. Patients and methods The Turkish version of VITACORA-19 questionnaire was obtained after a translation and back translation process. The study sample included 61 PsA patients (22 males, 39 females; mean age 46.5±12.2 years; range 19 to 71 years). To assess the test-retest reliability of the Turkish VITACORA-19, the questionnaire was reapplied 10 to 15 days after the first interview (interclass correlation coefficient). Cronbach’s alpha (a) was used to evaluate the internal consistency. VITACORA-19 was compared with visual analog scale for physician and patient global assessments, the Health Assessment Questionnaire, and Nottingham Health Profile for construct validity. The internal structure of VITACORA-19 was examined by factor analysis. Results The individual item intraclass correlation coefficient ranged from 0.77 to 0.98 and Cronbach's alpha ranged from 0.77 to 0.98. The Cronbach's alpha value for whole scale was determined as 0.96. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.90, and Bartlett's test of sphericity had a p<0.001. Turkish VITACORA-19 total scores were correlated negatively with Health Assessment Questionnaire, visual analog scale for pain, and Nottingham Health Profile subgroups, and positively with physician and patient global assessments (p<0.01). Conclusion Turkish version of VITACORA-19 questionnaire is a reliable and valid measure for health-related quality of life in Turkish patients with psoriatic arthritis. PMID:29900999

  13. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    PubMed Central

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  14. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    PubMed

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  15. Visual soil evaluation - future research requirements

    NASA Astrophysics Data System (ADS)

    Emmet-Booth, Jeremy; Forristal, Dermot; Fenton, Owen; Ball, Bruce; Holden, Nick

    2017-04-01

    A review of Visual Soil Evaluation (VSE) techniques (Emmet-Booth et al., 2016) highlighted their established utility for soil quality assessment, though some limitations were identified; (1) The examination of aggregate size, visible intra-porosity and shape forms a key assessment criterion in almost all methods, thus limiting evaluation to structural form. The addition of criteria that holistically examine structure may be desirable. For example, structural stability can be indicated using dispersion tests or examining soil surface crusting, while the assessment of soil colour may indirectly indicate soil organic matter content, a contributor to stability. Organic matter assessment may also indicate structural resilience, along with rooting, earthworm numbers or shrinkage cracking. (2) Soil texture may influence results or impeded method deployment. Modification of procedures to account for extreme texture variation is desirable. For example, evidence of compaction in sandy or single grain soils greatly differs to that in clayey soils. Some procedures incorporate separate classification systems or adjust deployment based on texture. (3) Research into impacts of soil moisture content on VSE evaluation criteria is required. Criteria such as rupture resistance and shape may be affected by moisture content. It is generally recommended that methods are deployed on moist soils and quantification of influences of moisture variation on results is necessary. (4) Robust sampling strategies for method deployment are required. Dealing with spatial variation differs between methods, but where methods can be deployed over large areas, clear instruction on sampling is required. Additionally, as emphasis has been placed on the agricultural production of soil, so the ability of VSE for exploring structural quality in terms of carbon storage, water purification and biodiversity support also requires research. References Emmet-Booth, J.P., Forristal. P.D., Fenton, O., Ball, B.C. & Holden, N.M. 2016. A review of visual soil evaluation techniques for soil structure. Soil Use and Management, 32, 623-634.

  16. Population-based assessment of vision-related quality of life in corneal disease: results from the CORE study.

    PubMed

    Vashist, Praveen; Gupta, Noopur; Tandon, Radhika; Gupta, Sanjeev K; Dwivedi, Sadanand; Mani, Kalaivani

    2016-05-01

    To assess the impact of corneal disease on vision-related quality of life (VR-QoL) in a rural North Indian population. Cross-sectional, population-based study. The Corneal Opacity Rural Epidemiological (CORE) study included 12 899 participants from 25 randomly selected clusters of rural Gurgaon, Haryana, India, with the primary objective of determining the prevalence of corneal disease in the general population during July 2011 to January 2013. VR-QoL was assessed through Indian Vision Function questionnaire (IND-VFQ-33) in adult participants (aged ≥18 years) detected with corneal opacity and equal number of healthy controls (no ocular pathology with visual acuity of 6/6 binocularly) selected from the same clusters. Scores of the three subscales of IND-VFQ-33 (vision-specific mobility, psychosocial impact and visual symptoms) were computed, analysed and compared separately across various groups. Overall, 12 113 participants of all ages underwent detailed ophthalmic examination and VR-QoL was assessed in 435 cases with corneal disease and 435 controls without any ophthalmic disease. The diseased population had significantly higher scores and hence poorer VR-QoL across all three domains of vision function (scores of 28 vs 22; 6 vs 5 and 14 vs 9, respectively; p<0.0001) and the scores were inversely related with the level of visual impairment in patients with corneal disease. Patients with unilateral corneal disease also had poorer VR-QoL scores as compared with healthy controls (p<0.0001). VR-QoL is impaired in patients with corneal disease, more so in patients with corneal blindness. This is the first population-based study to document VR-QoL through IND-VFQ-33 in the Indian population with corneal disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Visual resources of the New Jersey Pine Barrens: integrating visual resources into the planning process

    Treesearch

    John W. Sinton

    1979-01-01

    The first purpose of this study was to deter-mine the visual quality of New Jersey Pine Barrens forests according to residents of the area. The goal of the study was to determine how to manage Pine Barrens forests to obtain high visual quality within the framework of residents' preferences, available by the Federal Omnibus Parks Acts of 1978 and proposed New...

  18. The association between clinical parameters and glaucoma-specific quality of life in Chinese primary open-angle glaucoma patients.

    PubMed

    Lee, Jacky W Y; Chan, Catherine W S; Chan, Jonathan C H; Li, Q; Lai, Jimmy S M

    2014-08-01

    OBJECTIVE. To investigate the association between clinical measurements and glaucoma-specific quality of life in Chinese glaucoma patients. DESIGN. Cross-sectional study. SETTING. An academic hospital in Hong Kong. PATIENTS. A Chinese translation of the Glaucoma Quality of Life-15 questionnaire was completed by 51 consecutive patients with bilateral primary open-angle glaucoma. The binocular means of several clinical measurements were correlated with Glaucoma Quality of Life-15 findings using Pearson's correlation coefficient and linear regression. The measurements were the visual field index and pattern standard deviation from the Humphrey Field Analyzer, Snellen best-corrected visual acuity, presenting intra-ocular pressure, current intra-ocular pressure, average retinal nerve fibre layer thickness via optical coherence tomography, and the number of topical anti-glaucoma medications being used. RESULTS. In these patients, there was a significant correlation and linear relationship between a poorer Glaucoma Quality of Life-15 score and a lower visual field index (r=0.3, r(2)=0.1, P=0.01) and visual acuity (r=0.3, r(2)=0.1, P=0.03). A thinner retinal nerve fibre layer also correlated with a poorer Glaucoma Quality of Life-15 score, but did not attain statistical significance (r=0.3, P=0.07). There were no statistically significant correlations for the other clinical parameters with the Glaucoma Quality of Life-15 scores (all P values being >0.7). The three most problematic activities affecting quality of life were "adjusting to bright lights", "going from a light to a dark room or vice versa", and "seeing at night". CONCLUSION. For Chinese primary open-angle glaucoma patients, binocular visual field index and visual acuity correlated linearly with glaucoma-specific quality of life, and activities involving dark adaptation were the most problematic.

  19. Sight or Scent: Lemur Sensory Reliance in Detecting Food Quality Varies with Feeding Ecology

    PubMed Central

    Rushmore, Julie; Leonhardt, Sara D.; Drea, Christine M.

    2012-01-01

    Visual and olfactory cues provide important information to foragers, yet we know little about species differences in sensory reliance during food selection. In a series of experimental foraging studies, we examined the relative reliance on vision versus olfaction in three diurnal, primate species with diverse feeding ecologies, including folivorous Coquerel's sifakas (Propithecus coquereli), frugivorous ruffed lemurs (Varecia variegata spp), and generalist ring-tailed lemurs (Lemur catta). We used animals with known color-vision status and foods for which different maturation stages (and hence quality) produce distinct visual and olfactory cues (the latter determined chemically). We first showed that lemurs preferentially selected high-quality foods over low-quality foods when visual and olfactory cues were simultaneously available for both food types. Next, using a novel apparatus in a series of discrimination trials, we either manipulated food quality (while holding sensory cues constant) or manipulated sensory cues (while holding food quality constant). Among our study subjects that showed relatively strong preferences for high-quality foods, folivores required both sensory cues combined to reliably identify their preferred foods, whereas generalists could identify their preferred foods using either cue alone, and frugivores could identify their preferred foods using olfactory, but not visual, cues alone. Moreover, when only high-quality foods were available, folivores and generalists used visual rather than olfactory cues to select food, whereas frugivores used both cue types equally. Lastly, individuals in all three of the study species predominantly relied on sight when choosing between low-quality foods, but species differed in the strength of their sensory biases. Our results generally emphasize visual over olfactory reliance in foraging lemurs, but we suggest that the relative sensory reliance of animals may vary with their feeding ecology. PMID:22870229

  20. The potential of pigeons as surrogate observers in medical image perception studies

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Levenson, Richard M.; Navarro, Victor; Wasserman, Edward A.

    2016-03-01

    Assessment of medical image quality and how changes in image appearance impact performance are critical but assessment can be expensive and time-consuming. Could an animal (pigeon) observer with well-known visual skills and documented ability to distinguish complex visual stimuli serve as a surrogate for the human observer? Using sets of whole slide pathology (WSI) and mammographic images we trained pigeons (cohorts of 4) to detect and/or classify lesions in medical images. Standard training methods were used. A chamber equipped with a 15' display with a resistive touchscreen was used to display the images and record responses (pecks). Pigeon pellets were dispensed for correct responses. The pigeons readily learned to distinguish benign from malignant breast cancer histopathology in WSI (mean % correct responses rose 50% to 85% over 15 days) and generalized readily from 4X to 10X and 20X magnifications; to detect microcalcifications (mean % correct responses rose 50% to over 85% over 25 days); to distinguish benign from malignant breast masses (3 of 4 birds learned this task to around 80% and 60% over 10 days); and ignore compression artifacts in WSI (performance with uncompressed slides averaged 95% correct; 15:1 and 27:1 compression slides averaged 92% and 90% correct). Pigeons models may help us better understand medical image perception and may be useful in quality assessment by serving as surrogate observers for certain types of studies.

  1. Quality-Related Monitoring and Grading of Granulated Products by Weibull-Distribution Modeling of Visual Images with Semi-Supervised Learning.

    PubMed

    Liu, Jinping; Tang, Zhaohui; Xu, Pengfei; Liu, Wenzhong; Zhang, Jin; Zhu, Jianyong

    2016-06-29

    The topic of online product quality inspection (OPQI) with smart visual sensors is attracting increasing interest in both the academic and industrial communities on account of the natural connection between the visual appearance of products with their underlying qualities. Visual images captured from granulated products (GPs), e.g., cereal products, fabric textiles, are comprised of a large number of independent particles or stochastically stacking locally homogeneous fragments, whose analysis and understanding remains challenging. A method of image statistical modeling-based OPQI for GP quality grading and monitoring by a Weibull distribution(WD) model with a semi-supervised learning classifier is presented. WD-model parameters (WD-MPs) of GP images' spatial structures, obtained with omnidirectional Gaussian derivative filtering (OGDF), which were demonstrated theoretically to obey a specific WD model of integral form, were extracted as the visual features. Then, a co-training-style semi-supervised classifier algorithm, named COSC-Boosting, was exploited for semi-supervised GP quality grading, by integrating two independent classifiers with complementary nature in the face of scarce labeled samples. Effectiveness of the proposed OPQI method was verified and compared in the field of automated rice quality grading with commonly-used methods and showed superior performance, which lays a foundation for the quality control of GP on assembly lines.

  2. Soil structural quality assessment for soil protection regulation

    NASA Astrophysics Data System (ADS)

    Johannes, Alice; Boivin, Pascal

    2017-04-01

    Soil quality assessment is rapidly developing worldwide, though mostly focused on the monitoring of arable land and soil fertility. Soil protection regulations assess soil quality differently, focusing on priority pollutants and threshold values. The soil physical properties are weakly considered, due to lack of consensus and experimental difficulties faced with characterization. Non-disputable, easy to perform and inexpensive methods should be available for environmental regulation to be applied, which is unfortunately not the case. As a consequence, quantitative soil physical protection regulation is not applied, and inexpensive soil physical quality indicators for arable soil management are not available. Overcoming these limitations was the objective of a research project funded by the Swiss federal office for environment (FOEN). The main results and the perspectives of application are given in this presentation. A first step of the research was to characterize soils in a good structural state (reference soils) under different land use. The structural quality was assessed with field expertise and Visual Evaluation of the Soil Structure (VESS), and the physical properties were assessed with Shrinkage analysis. The relationships between the physical properties and the soil constituents were linear and highly determined. They represent the reference properties of the corresponding soils. In a second step, the properties of physically degraded soils were analysed and compared to the reference properties. This allowed defining the most discriminant parameters departing the different structure qualities and their threshold limits. Equivalent properties corresponding to these parameters but inexpensive and easy to determine were defined and tested. More than 90% of the samples were correctly classed with this method, which meets, therefore, the requirements for practical application in regulation. Moreover, result-oriented agri-environmental schemes for soil quality are now proposed to farmers based on these indicators.

  3. Effects of simulator motion and visual characteristics on rotorcraft handling qualities evaluations

    NASA Technical Reports Server (NTRS)

    Mitchell, David G.; Hart, Daniel C.

    1993-01-01

    The pilot's perceptions of aircraft handling qualities are influenced by a combination of the aircraft dynamics, the task, and the environment under which the evaluation is performed. When the evaluation is performed in a groundbased simulator, the characteristics of the simulation facility also come into play. Two studies were conducted on NASA Ames Research Center's Vertical Motion Simulator to determine the effects of simulator characteristics on perceived handling qualities. Most evaluations were conducted with a baseline set of rotorcraft dynamics, using a simple transfer-function model of an uncoupled helicopter, under different conditions of visual time delays and motion command washout filters. Differences in pilot opinion were found as the visual and motion parameters were changed, reflecting a change in the pilots' perceptions of handling qualities, rather than changes in the aircraft model itself. The results indicate a need for tailoring the motion washout dynamics to suit the task. Visual-delay data are inconclusive but suggest that it may be better to allow some time delay in the visual path to minimize the mismatch between visual and motion, rather than eliminate the visual delay entirely through lead compensation.

  4. Designing sound and visual components for enhancement of urban soundscapes.

    PubMed

    Hong, Joo Young; Jeon, Jin Yong

    2013-09-01

    The aim of this study is to investigate the effect of audio-visual components on environmental quality to improve soundscape. Natural sounds with road traffic noise and visual components in urban streets were evaluated through laboratory experiments. Waterfall and stream water sounds, as well as bird sounds, were selected to enhance the soundscape. Sixteen photomontages of a streetscape were constructed in combination with two types of water features and three types of vegetation which were chosen as positive visual components. The experiments consisted of audio-only, visual-only, and audio-visual conditions. The preferences and environmental qualities of the stimuli were evaluated by a numerical scale and 12 pairs of adjectives, respectively. The results showed that bird sounds were the most preferred among the natural sounds, while the sound of falling water was found to degrade the soundscape quality when the road traffic noise level was high. The visual effects of vegetation on aesthetic preference were significant, but those of water features relatively small. It was revealed that the perceptual dimensions of the environment were different from the noise levels. Particularly, the acoustic comfort factor related to soundscape quality considerably influenced preference for the overall environment at a higher level of road traffic noise.

  5. Underlying mechanisms of writing difficulties among children with neurofibromatosis type 1.

    PubMed

    Gilboa, Yafit; Josman, Naomi; Fattal-Valevski, Aviva; Toledano-Alhadef, Hagit; Rosenblum, Sara

    2014-06-01

    Writing is a complex activity in which lower-level perceptual-motor processes and higher-level cognitive processes continuously interact. Preliminary evidence suggests that writing difficulties are common to children with Neurofibromatosis type 1 (NF1). The aim of this study was to compare the performance of children with and without NF1 in lower (visual perception, motor coordination and visual-motor integration) and higher processes (verbal and performance intelligence, visual spatial organization and visual memory) required for intact writing; and to identify the components that predict the written product's spatial arrangement and content among children with NF1. Thirty children with NF1 (ages 8-16) and 30 typically developing children matched by gender and age were tested, using standardized assessments. Children with NF1 had a significantly inferior performance in comparison to control children, on all tests that measured lower and higher level processes. The cognitive planning skill was found as a predictor of the written product's spatial arrangement. The verbal intelligence predicted the written content level. Results suggest that high level processes underlie the poor quality of writing product in children with NF1. Treatment approaches for children with NF1 must include detailed assessments of cognitive planning and language skills. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Visualizations of Travel Time Performance Based on Vehicle Reidentification Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, Stanley Ernest; Sharifi, Elham; Day, Christopher M.

    This paper provides a visual reference of the breadth of arterial performance phenomena based on travel time measures obtained from reidentification technology that has proliferated in the past 5 years. These graphical performance measures are revealed through overlay charts and statistical distribution as revealed through cumulative frequency diagrams (CFDs). With overlays of vehicle travel times from multiple days, dominant traffic patterns over a 24-h period are reinforced and reveal the traffic behavior induced primarily by the operation of traffic control at signalized intersections. A cumulative distribution function in the statistical literature provides a method for comparing traffic patterns from variousmore » time frames or locations in a compact visual format that provides intuitive feedback on arterial performance. The CFD may be accumulated hourly, by peak periods, or by time periods specific to signal timing plans that are in effect. Combined, overlay charts and CFDs provide visual tools with which to assess the quality and consistency of traffic movement for various periods throughout the day efficiently, without sacrificing detail, which is a typical byproduct of numeric-based performance measures. These methods are particularly effective for comparing before-and-after median travel times, as well as changes in interquartile range, to assess travel time reliability.« less

  7. Radionuclide assessment of the effects of chest physical therapy on ventilation in cystic fibrosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeCesare, J.A.; Babchyck, B.M.; Colten, H.R.

    1982-06-01

    This study assesses the use of /sup 81m/Kr scintigraphy as a measurement tool in evaluating the effectiveness of bronchial drainage with percussion and vibration on peripheral ventilation in patients with cystic fibrosis. Ten patients with cystic fibrosis participated. Each patient underwent a /sup 81m/Kr ventilation study and traditional pulmonary function tests. Forty-five minutes later, these studies were repeated before and after a chest physical therapy treatment. Each patient acted as his own control. All /sup 81m/Kr scintiscans were recorded and analyzed visually and numerically using a digital computer to assess distribution of ventilation. Visual analysis of the scintiscans indicated individualmore » variation in treatment response: in some patients ventilation improved with therapy; in others, no change was noted; still others had changes independent of treatment. Numerical data derived from the scintiscans and pulmonary function tests showed no important differences among the three studies of each patient. Airway abnormalities characteristic of cystic fibrosis, progression of the disease, sputum production, or a combination of these factors may account for the individual variation in response to treatment. /sup 81m/Kr scintigraphy is a reliable measure of regional ventilation and should be useful for assessing the efficacy of chest physical therapy because of the consistent, high quality visual data retrieved.« less

  8. Image quality assessment for CT used on small animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cisneros, Isabela Paredes, E-mail: iparedesc@unal.edu.co; Agulles-Pedrós, Luis, E-mail: lagullesp@unal.edu.co

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters usingmore » an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.« less

  9. Image quality assessment for CT used on small animals

    NASA Astrophysics Data System (ADS)

    Cisneros, Isabela Paredes; Agulles-Pedrós, Luis

    2016-07-01

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MatLab, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  10. A multicenter study on the health-related quality of life of cataract patients: baseline data.

    PubMed

    Yamada, Masakazu; Mizuno, Yoshinobu; Miyake, Yozo

    2009-09-01

    This study examines the impact of cataracts on health-related quality of life (HR-QOL) and health events in the older population. The study population consisted of 439 unoperated cataract patients aged 60 years or older who visited any of the facilities affiliated with the Cataract Survey Group of the National Hospital Organization of Japan, which has been conducting a prospective multicenter cohort study on cataract patients. HR-QOL of the patients was assessed using the Japanese version of Visual Function Questionnaire-25 (VFQ-25) and the 8-Item Short-Form Health Survey (SF-8). The health condition and health events of the patients were also investigated. The average age of the 439 patients enrolled (126 men and 313 women) was 73.0 +/- 7.1 years. There were 323 patients with comorbidities (73.6%), 81 of whom (23.7%) felt it was hard to visit the hospital owing to their visual impairment. In the previous year, 74 patients (16.9%) had experienced a fall and 14 (3.2%) had been in a traffic accident. Of those, 43.2% and 8.3% respectively answered that the falls and the accident could have been triggered by their visual impairment. When the patients were classified according to visual acuity, most of the VFQ-25 subscale scores declined significantly with decreasing visual acuity, whereas the SF-8 scores showed no significant change. The participants of this study were patients with unoperated cataract, and thus the decline of HR-QOL was modest. The survey of health events, however, revealed that the visual constraint has a certain impact on the daily lives of the older population.

  11. Longitudinal Impact on Quality of Life for School-aged Children with Amblyopia Treatment: Perspective from Children.

    PubMed

    Chen, Yanyan; Chen, Xinhong; Chen, Jie; Zheng, Jingwei; Xu, Jinling; Yu, Xinping

    2016-01-01

    To evaluate the longitudinal impact on health-related quality of life (HRQOL) during amblyopia treatment for school-aged children from children's perspective. School-aged children prescribed amblyopia treatment for the first time were recruited into the current study. Using a questionnaire, subjects' HRQOL was assessed before patching treatment, and at 8 weeks and 16 weeks after the commencement of patching treatment. Evaluation of visual function and psychosocial aspect was included in the questionnaire. Visual acuity and demographic data of the subjects were recorded. Forty-four children, aged 7-12 years, with anisometropic amblyopia were included in the study. Visual acuity in the amblyopic eye improved 1.90 (0.41-3.74) and 3.98 (2.22-5.11) lines at follow-up weeks 8 and 16, respectively. Both the total score and subscales of the questionnaire were reduced at the first follow-up and recovered at the second follow-up. Scores at week 16 were higher than those before treatment in the psychosocial aspect (p = 0.003), and lower in the visual function aspect (p < 0.001), without significant difference in total score (p = 0.207). Visual acuity in the amblyopic eye and psychosocial expectations for treatment were the most important factors that influenced HRQOL during treatment. From the children's perspective, the impacts on visual function and psychosocial aspect were significant in the first two months of treatment, and could be adapted during therapy for school-aged children. More attention should be paid to negative effects of treatment on daily life and study at the stage of amblyopia treatment for school-aged children. Meanwhile, necessary precautions should be taken to help reduce the impacts.

  12. Retinal and Optic Nerve Degeneration in Patients with Multiple Sclerosis Followed up for 5 Years.

    PubMed

    Garcia-Martin, Elena; Ara, Jose R; Martin, Jesus; Almarcegui, Carmen; Dolz, Isabel; Vilades, Elisa; Gil-Arribas, Laura; Fernandez, Francisco J; Polo, Vicente; Larrosa, Jose M; Pablo, Luis E; Satue, Maria

    2017-05-01

    To quantify retinal nerve fiber layer (RNFL) changes in patients with multiple sclerosis (MS) and healthy controls with a 5-year follow-up and to analyze correlations between disability progression and RNFL degeneration. Observational and longitudinal study. One hundred patients with relapsing-remitting MS and 50 healthy controls. All participants underwent a complete ophthalmic and electrophysiologic exploration and were re-evaluated annually for 5 years. Visual acuity (Snellen chart), color vision (Ishihara pseudoisochromatic plates), visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (SLP), and visual evoked potentials. Expanded Disability Status Scale (EDSS) scores, disease duration, treatments, prior optic neuritis episodes, and quality of life (QOL; based on the 54-item Multiple Sclerosis Quality of Life Scale score). Optical coherence tomography (OCT) revealed changes in all RNFL thicknesses in both groups. In the MS group, changes were detected in average thickness and in the mean deviation using the GDx-VCC nerve fiber analyzer (Laser Diagnostic Technologies, San Diego, CA) and in the P100 latency of visual evoked potentials; no changes were detected in visual acuity, color vision, or visual fields. Optical coherence tomography showed greater differences in the inferior and temporal RNFL thicknesses in both groups. In MS patients only, OCT revealed a moderate correlation between the increase in EDSS and temporal and superior RNFL thinning. Temporal RNFL thinning based on OCT results was correlated moderately with decreased QOL. Multiple sclerosis patients exhibit a progressive axonal loss in the optic nerve fiber layer. Retinal nerve fiber layer thinning based on OCT results is a useful marker for assessing MS progression and correlates with increased disability and reduced QOL. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Relationship Between Rates of Binocular Visual Field Loss and Vision-Related Quality of Life in Glaucoma

    PubMed Central

    Lisboa, Renato; Chun, Yeoun Sook; Zangwill, Linda M.; Weinreb, Robert N.; Rosen, Peter N.; Liebmann, Jeffrey M.; Girkin, Christopher A.; Medeiros, Felipe A.

    2013-01-01

    Objective To evaluate the relationship between binocular rates of visual field change and vision-related quality of life (VRQOL) in glaucoma. Methods The study included 796 eyes of 398 participants that had diagnosed or suspected glaucoma followed for an average of 7.3 ± 2.0 years. Subjects were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES). VRQOL was evaluated using the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) at the last follow-up visit. Integrated binocular visual fields (BVF) were calculated from the monocular fields of each patient. Linear regression of mean deviation (MD) values was used to evaluate rates of visual field change during the follow-up period. Logistic regression models were used to investigate the relationship between abnormal VRQOL and rates of visual field change, while adjusting for potentially confounding socio-economic and demographic variables. Results Thirty-two patients (8.0%) had abnormal VRQOL as determined by the results of the NEI VFQ-25 questionnaire. Subjects with abnormal VRQOL had significantly faster rates of BVF change than those with normal VRQOL (−0.18 db/year vs. −0.06 dB/year, respectively; P < 0.001). Rates of BVF change were significantly associated with abnormality in VRQOL (OR = 1.31 per 0.1dB/year faster; P = 0.038), after adjustment for confounding variables. Conclusions Patients with faster rates of BVF change were at higher risk of reporting abnormal VRQOL. Assessment of rates of BVF change may provide useful information in determining risk of functional impairment in glaucoma. PMID:23450425

  14. Image quality classification for DR screening using deep learning.

    PubMed

    FengLi Yu; Jing Sun; Annan Li; Jun Cheng; Cheng Wan; Jiang Liu

    2017-07-01

    The quality of input images significantly affects the outcome of automated diabetic retinopathy (DR) screening systems. Unlike the previous methods that only consider simple low-level features such as hand-crafted geometric and structural features, in this paper we propose a novel method for retinal image quality classification (IQC) that performs computational algorithms imitating the working of the human visual system. The proposed algorithm combines unsupervised features from saliency map and supervised features coming from convolutional neural networks (CNN), which are fed to an SVM to automatically detect high quality vs poor quality retinal fundus images. We demonstrate the superior performance of our proposed algorithm on a large retinal fundus image dataset and the method could achieve higher accuracy than other methods. Although retinal images are used in this study, the methodology is applicable to the image quality assessment and enhancement of other types of medical images.

  15. Assessment of gunshot bullet injuries with the use of magnetic resonance imaging.

    PubMed

    Hess, U; Harms, J; Schneider, A; Schleef, M; Ganter, C; Hannig, C

    2000-10-01

    Magnetic resonance imaging (MRI) is rarely used for preoperative assessment of shotgun injuries because of concerns of displacing the possibly ferromagnetic foreign body within the surrounding tissue. A total of 56 different projectiles underwent MRI testing for ferromagnetism and imaging quality in vitro and in pig carcasses with a commercially available 1.5-MRI scan. Image quality was compared with that of computed tomographic scans. Projectiles with ferromagnetic properties can be distinguished easily from nonferromagnetic ones by pretesting the motion of an identical projectile within the MRI coil. When ferromagnetic projectiles were excluded, MRI yielded the more precise images compared with other imaging techniques. Projectile localization and associated soft tissue injuries were visualized without artifacts in all cases. When ferromagnetic foreign bodies are excluded by pretesting their properties within the MRI with a comparative projectile, MRI portends an excellent imaging procedure for assessing the extent of injury and planning the removal by surgery.

  16. Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment Update

    PubMed Central

    Lee, Christine; Tu, Hong Anh; Wells, David; Holubowich, Corinne

    2017-01-01

    Background Retinitis pigmentosa is a group of inherited disorders characterized by the degeneration of the photoreceptors in the retina, resulting in progressive vision loss. The Argus II system is designed to restore partial functional vision in patients with profound vision loss from advanced retinitis pigmentosa. At present, it is the only treatment option approved by Health Canada for this patient population. In June 2016, Health Quality Ontario published a health technology assessment of the Argus II retinal prosthesis system for patients with advanced retinitis pigmentosa. Based on that assessment, the Ontario Health Technology Advisory Committee recommended against publicly funding the Argus II system for this population. It also recommended that Health Quality Ontario re-evaluate the evidence in 1 year. The objective of this report was to examine new evidence published since the 2016 health technology assessment. Methods We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences related to the Argus II system. We performed a systematic literature search for studies published since the 2016 Argus II health technology assessment. We developed a Markov decision-analytic model to assess the cost-effectiveness of the Argus II system compared with standard care, and we calculated incremental cost-effectiveness ratios over a 20-year time horizon. We also conducted a five-year budget impact analysis. Finally, we interviewed people with retinitis pigmentosa about their lived experience with vision loss, and with the Argus II system. Results Four publications from one multicentre international study were included in the clinical review. Patients showed significant improvements in visual function and functional outcomes with the Argus II system, and these outcomes were sustained up to a 5-year follow-up (moderate quality of evidence). The safety profile was generally acceptable. In the base case economic analysis, the Argus II system was cost-effective compared with standard care if the willingness to pay was more than $97,429 per quality-adjusted life-year. We estimated that funding the Argus II system would cost the province $0.71 to $0.78 million per year over 5 years, assuming 4 implants per year. People with lived experience spoke about the challenges of retinitis pigmentosa, including the gradual but persistent progression of the disease; its impact on their quality of life and their families; and the accessibility challenges they faced. Those who used the Argus II system spoke about its positive impact on their quality of life. Conclusions Based on evidence of moderate quality, the Argus II retinal prosthesis system improved visual function, real-life functional outcomes, and quality of life in patients with advanced retinitis pigmentosa. The Argus II system is expensive, but the cost to publicly fund it would be low, because of the small number of eligible patients. The Argus II system can only enable perception of light/dark and shapes/objects, but these advancements represent important gains for people with retinitis pigmentosa in terms of mobility and quality of life. PMID:29201260

  17. Correction of Refractive Errors in Rhesus Macaques (Macaca mulatta) Involved in Visual Research

    PubMed Central

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-01-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals. PMID:25427343

  18. Correction of refractive errors in rhesus macaques (Macaca mulatta) involved in visual research.

    PubMed

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-08-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.

  19. Intraoperative electrostimulation objectifies the assessment of functional nerve preservation after mesorectal excision.

    PubMed

    Kneist, W; Junginger, T

    2007-06-01

    To improve nerve-sparing surgery, intraoperative electrical stimulation of pelvic autonomic nerves (INS) has been proposed in urology, gynecology, and visceral surgery. The aim of this study was to assess the impact of INS while monitoring intravesical pressure on the accurate evaluation of pelvic autonomic nerve preservation (PANP) after mesorectal excision. It was sought to determine whether this confirmation is useful in the prediction of postoperative urinary function. Sixty-two patients with mesorectal exzision for rectal cancer were examined prospectively. PANP was assessed visually by the surgeon and with INS. Bladder function was evaluated by post voiding residual volume measurement, rate of recatheterization, rate of long-term urinary catheterisation, and the international prostatic symptom score with quality of life index. INS confirmed bilateral preservation of parasympathetic nerves in 46 patients (74%), and in 10 patients (16%) in at least one side. In six patients (10%), INS failed to confirm PANP. Eleven patients (18%) developed urinary symptoms postoperatively. INS results had a higher sensitivity than visual assessment by the surgeon (82 vs 46%). Values for specificity ranged at 90 and 92%, respectively. Accuracy of INS in predicting PANP was higher (88 vs 83%). The correlation between urinary function and the findings on INS was good (kappa-value: 0.65), correlation between urinary function and visual assessment by the surgeon was fair (kappa-value: 0.40). INS, while monitoring intravesical pressure, accurately predicts bladder function after mesorectal excision. It may provide further insight into pelvic autonomic nerve sparing techniques.

  20. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  1. Mandibular trabecular bone as fracture indicator in 80-year-old men and women.

    PubMed

    Hassani-Nejad, Azar; Ahlqwist, Margareta; Hakeberg, Magnus; Jonasson, Grethe

    2013-12-01

    The objective of the present study was to compare assessments of the mandibular bone as fracture risk indicators for 277 men and women. The mandibular trabecular bone was evaluated in periapical radiographs, using a visual index, as dense, mixed dense and sparse, or sparse. Bone texture was analysed using a computer-based method in which the number of transitions from trabeculae to intertrabecular spaces was calculated. The sum of the sizes and intensities of the spaces between the trabeculae was calculated using Jaw-X software. Women had a statistically significantly greater number of fractures and a higher frequency of sparse mandibular bone. The OR for having suffered a fracture with visually sparse trabecular bone was highest for the male group (OR = 5.55) and lowest for the female group (OR = 3.35). For bone texture as an indicator of previous fracture, the OR was significant for the female group (OR = 2.61) but not for the male group, whereas the Jaw-X calculations did not differentiate between fractured and non-fractured groups. In conclusion, all bone-quality assessments showed that women had a higher incidence of sparse trabecular bone than did men. Only the methods of visual assessment and trabecular texture were significantly correlated with previous bone fractures. © 2013 Eur J Oral Sci.

  2. Body odor quality predicts behavioral attractiveness in humans.

    PubMed

    Roberts, S Craig; Kralevich, Alexandra; Ferdenzi, Camille; Saxton, Tamsin K; Jones, Benedict C; DeBruine, Lisa M; Little, Anthony C; Havlicek, Jan

    2011-12-01

    Growing effort is being made to understand how different attractive physical traits co-vary within individuals, partly because this might indicate an underlying index of genetic quality. In humans, attention has focused on potential markers of quality such as facial attractiveness, axillary odor quality, the second-to-fourth digit (2D:4D) ratio and body mass index (BMI). Here we extend this approach to include visually-assessed kinesic cues (nonverbal behavior linked to movement) which are statistically independent of structural physical traits. The utility of such kinesic cues in mate assessment is controversial, particularly during everyday conversational contexts, as they could be unreliable and susceptible to deception. However, we show here that the attractiveness of nonverbal behavior, in 20 male participants, is predicted by perceived quality of their axillary body odor. This finding indicates covariation between two desirable traits in different sensory modalities. Depending on two different rating contexts (either a simple attractiveness rating or a rating for long-term partners by 10 female raters not using hormonal contraception), we also found significant relationships between perceived attractiveness of nonverbal behavior and BMI, and between axillary odor ratings and 2D:4D ratio. Axillary odor pleasantness was the single attribute that consistently predicted attractiveness of nonverbal behavior. Our results demonstrate that nonverbal kinesic cues could reliably reveal mate quality, at least in males, and could corroborate and contribute to mate assessment based on other physical traits.

  3. First quality score for referral letters in gastroenterology—a validation study

    PubMed Central

    Eskeland, Sigrun Losada; Brunborg, Cathrine; Seip, Birgitte; Wiencke, Kristine; Hovde, Øistein; Owen, Tanja; Skogestad, Erik; Huppertz-Hauss, Gert; Halvorsen, Fred-Arne; Garborg, Kjetil; Aabakken, Lars; de Lange, Thomas

    2016-01-01

    Objective To create and validate an objective and reliable score to assess referral quality in gastroenterology. Design An observational multicentre study. Setting and participants 25 gastroenterologists participated in selecting variables for a Thirty Point Score (TPS) for quality assessment of referrals to gastroenterology specialist healthcare for 9 common indications. From May to September 2014, 7 hospitals from the South-Eastern Norway Regional Health Authority participated in collecting and scoring 327 referrals to a gastroenterologist. Main outcome measure Correlation between the TPS and a visual analogue scale (VAS) for referral quality. Results The 327 referrals had an average TPS of 13.2 (range 1–25) and an average VAS of 4.7 (range 0.2–9.5). The reliability of the score was excellent, with an intra-rater intraclass correlation coefficient (ICC) of 0.87 and inter-rater ICC of 0.91. The overall correlation between the TPS and the VAS was moderate (r=0.42), and ranged from fair to substantial for the various indications. Mean agreement was good (ICC=0.47, 95% CI (0.34 to 0.57)), ranging from poor to good. Conclusions The TPS is reliable, objective and shows good agreement with the subjective VAS. The score may be a useful tool for assessing referral quality in gastroenterology, particularly important when evaluating the effect of interventions to improve referral quality. PMID:27855107

  4. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system

    PubMed Central

    Wood, T J; Beavis, A W; Saunderson, J R

    2013-01-01

    Objective: The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. Methods: The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson’s correlation coefficient. Results: Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Conclusion: Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. Advances in knowledge: A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography. PMID:23568362

  5. The need for an objective measure in septorhinoplasty surgery: are we any closer to finding an answer?

    PubMed

    Andrews, P J; Choudhury, N; Takhar, A; Poirrier, A L; Jacques, T; Randhawa, P S

    2015-12-01

    To assess the reliability of nasal inspiratory peak flow (NIPF) in providing a clinically accurate objective measure following functional septorhinoplasty by comparing it to the validated disease-specific quality-of-life questionnaire, SNOT-22. Studies so far have demonstrated poor correlation between bilateral NIPF and symptom-specific nasal questionnaires following septorhinoplasty. To perform a prospective comparative analysis between NIPF and the validated disease-specific quality-of-life questionnaire SNOT-22 and to determine whether a correlation exists following septorhinoplasty surgery. The Royal National Throat Nose and Ear Hospital, London. A total of 122 patients (78 males, 44 females; mean age 33.5 ± 12.2 years) were recruited from the senior authors rhinology clinic and underwent functional septorhinoplasty surgery. Preoperative and postoperative nasal inspiratory peak flow (NIPF) measurements were performed in addition to the completion of three subjective quality-of-life and symptom assessment tool questionnaires; Sinonasal Outcome Test 22 (SNOT-22), Nasal Obstruction Symptom Evaluation (NOSE) and Visual Analogue Scale (VAS: 0-10). The mean preoperative NIPF was 88.2 L/min, and the postoperative value was 101.6 L/min and showed a significant improvement following surgery (P = 0.0064). The mean total SNOT-22 score improved significantly from 48.6 to 26.6 (P < 0.0001); the NOSE score from 14.1 to 6.6 (P < 0.0001); and the Visual Analogue Scale (VAS) blockage score from 6.9 to 3.2 (P < 0.0001). All individual domains assessed showed improvements postoperatively, but no correlation was found between the NIPF and SNOT-22 score. Equally, we did not find a correlation between NIPF and the symptom-specific NOSE questionnaire and the nasal blockage domain on the Visual Analogue Scale (VAS) scale. We have demonstrated that NIPF does not correlate with the SNOT-22 disease-specific questionnaire, although both outcomes significantly improve postoperatively. At present, we are still lacking a clinically accurate objective measure of nasal function for the evaluation of patients undergoing septorhinoplasty surgery. © 2015 John Wiley & Sons Ltd.

  6. Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

    PubMed Central

    Yıldırım Karabağ, Revan; Günenç, Üzeyir; Aydın, Rukiye; Arıkan, Gül; Aslankara, Hüseyin

    2018-01-01

    Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a “mix and match” approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients’ dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their non-dominant eyes. Monocular and binocular uncorrected distance, intermediate and near visual acuity (logMAR), and contrast sensitivity levels were measured at 1, 3, and 6 months after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, and halo and glare symptoms were also evaluated at 6 months after the surgery. Postoperative quality of life was assessed with the Turkish version of National Eye Institute Visual Function Questionnaire-25. Results The study group comprised 8 females and 12 males with a mean age of 69.45±10.76 years (range, 31-86 years). The uncorrected distance and intermediate visual acuity levels were significantly better in the ReZoom-implanted eyes at postoperative 6 months (p=0.026 and p=0.037, respectively). There was no statistically significant difference in uncorrected near visual acuity (p>0.05). There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p<0.05). Mild glare/halo was reported by 40% of the subjects. The mean patient satisfaction was 95% and all patients were spectacle independent. Conclusion Mixing and matching multifocal IOLs in selected cataract patients provides excellent visual outcome, a high level of patient satisfaction, and spectacle independency. PMID:29576891

  7. Community screening for visual impairment in older people.

    PubMed

    Clarke, Emily L; Evans, Jennifer R; Smeeth, Liam

    2018-02-20

    Visual problems in older people are common and frequently under-reported. The effects of poor vision in older people are wide reaching and include falls, confusion and reduced quality of life. Much of the visual impairment in older ages can be treated (e.g. cataract surgery, correction of refractive error). Vision screening may therefore reduce the number of older people living with sight loss. The objective of this review was to assess the effects on vision of community vision screening of older people for visual impairment. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 10); Ovid MEDLINE; Ovid Embase; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 23 November 2017. We included randomised controlled trials (RCTs) that compared vision screening alone or as part of a multi-component screening package as compared to no vision screening or standard care, on the vision of people aged 65 years or over in a community setting. We included trials that used self-reported visual problems or visual acuity testing as the screening tool. We used standard methods expected by Cochrane. We graded the certainty of the evidence using GRADE. Visual outcome data were available for 10,608 people in 10 trials. Four trials took place in the UK, two in Australia, two in the United States and two in the Netherlands. Length of follow-up ranged from one to five years. Three of these studies were cluster-randomised trials whereby general practitioners or family physicians were randomly allocated to undertake vision screening or no vision screening. All studies were funded by government agencies. Overall we judged the studies to be at low risk of bias and only downgraded the certainty of the evidence (GRADE) for imprecision.Seven trials compared vision screening as part of a multi-component screening versus no screening. Six of these studies used self-reported vision as both screening tool and outcome measure, but did not directly measure vision. One study used a combination of self-reported vision and visual acuity measurement: participants reporting vision problems at screening were treated by the attending doctor, referred to an eye care specialist or given information about resources that were available to assist with poor vision. There was a similar risk of "not seeing well" at follow-up in people screened compared with people not screened in meta-analysis of six studies (risk ratio (RR) 1.05, 95% confidence interval (CI) 0.97 to 1.14, 4522 participants high-certainty evidence). One trial reported "improvement in vision" and this occurred slightly less frequently in the screened group (RR 0.85, 95% CI 0.52 to 1.40, 230 participants, moderate-certainty evidence).Two trials compared vision screening (visual acuity testing) alone with no vision screening. In one study, distance visual acuity was similar in the two groups at follow-up (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.05, 532 participants, high-certainty evidence). There was also little difference in near acuity (MD 0.02 logMAR, 95% CI -0.03 to 0.07, 532 participants, high-certainty evidence). There was no evidence of any important difference in quality of life (MD -0.06 National Eye Institute 25-item visual function questionnaire (VFQ-25) score adjusted for baseline VFQ-25 score, 95% CI -2.3 to 1.1, 532 participants, high-certainty evidence). The other study could not be included in the data analysis as the number of participants in each of the arms at follow-up could not be determined. However the authors stated that there was no significant difference in mean visual acuity in participants who had visual acuity assessed at baseline (39 letters) as compared to those who did not have their visual acuity assessed (35 letters, P = 0.25, 121 participants).One trial compared a detailed health assessment including measurement of visual acuity (intervention) with a brief health assessment including one question about vision (standard care). People given the detailed health assessment had a similar risk of visual impairment (visual acuity worse than 6/18 in either eye) at follow-up compared with people given the brief assessment (RR 1.07, 95% CI 0.84 to 1.36, 1807 participants, moderate-certainty evidence). The mean composite score of the VFQ-25 was 86.0 in the group that underwent visual acuity screening compared with 85.6 in the standard care group, a difference of 0.40 (95% CI -1.70 to 2.50, 1807 participants, high-certainty evidence). The evidence from RCTs undertaken to date does not support vision screening for older people living independently in a community setting, whether in isolation or as part of a multi-component screening package. This is true for screening programmes involving questions about visual problems, or direct measurements of visual acuity.The most likely reason for this negative review is that the populations within the trials often did not take up the offered intervention as a result of the vision screening and large proportions of those who did not have vision screening appeared to seek their own intervention. Also, trials that use questions about vision have a lower sensitivity and specificity than formal visual acuity testing. Given the importance of visual impairment among older people, further research into strategies to improve vision of older people is needed. The effectiveness of an optimised primary care-based screening intervention that overcomes possible factors contributing to the observed lack of benefit in trials to date warrants assessment; trials should consider including more dependent participants, rather than those living independently in the community.

  8. A Visual Analytics Approach for Station-Based Air Quality Data

    PubMed Central

    Du, Yi; Ma, Cuixia; Wu, Chao; Xu, Xiaowei; Guo, Yike; Zhou, Yuanchun; Li, Jianhui

    2016-01-01

    With the deployment of multi-modality and large-scale sensor networks for monitoring air quality, we are now able to collect large and multi-dimensional spatio-temporal datasets. For these sensed data, we present a comprehensive visual analysis approach for air quality analysis. This approach integrates several visual methods, such as map-based views, calendar views, and trends views, to assist the analysis. Among those visual methods, map-based visual methods are used to display the locations of interest, and the calendar and the trends views are used to discover the linear and periodical patterns. The system also provides various interaction tools to combine the map-based visualization, trends view, calendar view and multi-dimensional view. In addition, we propose a self-adaptive calendar-based controller that can flexibly adapt the changes of data size and granularity in trends view. Such a visual analytics system would facilitate big-data analysis in real applications, especially for decision making support. PMID:28029117

  9. A Visual Analytics Approach for Station-Based Air Quality Data.

    PubMed

    Du, Yi; Ma, Cuixia; Wu, Chao; Xu, Xiaowei; Guo, Yike; Zhou, Yuanchun; Li, Jianhui

    2016-12-24

    With the deployment of multi-modality and large-scale sensor networks for monitoring air quality, we are now able to collect large and multi-dimensional spatio-temporal datasets. For these sensed data, we present a comprehensive visual analysis approach for air quality analysis. This approach integrates several visual methods, such as map-based views, calendar views, and trends views, to assist the analysis. Among those visual methods, map-based visual methods are used to display the locations of interest, and the calendar and the trends views are used to discover the linear and periodical patterns. The system also provides various interaction tools to combine the map-based visualization, trends view, calendar view and multi-dimensional view. In addition, we propose a self-adaptive calendar-based controller that can flexibly adapt the changes of data size and granularity in trends view. Such a visual analytics system would facilitate big-data analysis in real applications, especially for decision making support.

  10. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    PubMed

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  11. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    PubMed

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  12. Poster presentations at medical conferences: an effective way of disseminating research?

    PubMed

    Goodhand, J R; Giles, C L; Wahed, M; Irving, P M; Langmead, L; Rampton, D S

    2011-04-01

    This study aimed to ascertain the value of posters at medical meetings to presenters and delegates. The usefulness of posters to presenters at national and international meetings was evaluated by assessing the numbers of delegates visiting them and the reasons why they visited. Memorability of selected posters was assessed and factors influencing their appeal to expert delegates identified. At both the national and international meetings, very few delegates (< 5%) visited posters. Only a minority read them and fewer asked useful questions. Recall of content was so poor that it prevented identification of factors improving their memorability. Factors increasing posters' visual appeal included their scientific content, pictures/graphs and limited use of words. Few delegates visit posters and those doing so recall little of their content. To engage their audience, researchers should design visually appealing posters by presenting high quality data in pictures or graphs without an excess of words.

  13. A Case-Based Study with Radiologists Performing Diagnosis Tasks in Virtual Reality.

    PubMed

    Venson, José Eduardo; Albiero Berni, Jean Carlo; Edmilson da Silva Maia, Carlos; Marques da Silva, Ana Maria; Cordeiro d'Ornellas, Marcos; Maciel, Anderson

    2017-01-01

    In radiology diagnosis, medical images are most often visualized slice by slice. At the same time, the visualization based on 3D volumetric rendering of the data is considered useful and has increased its field of application. In this work, we present a case-based study with 16 medical specialists to assess the diagnostic effectiveness of a Virtual Reality interface in fracture identification over 3D volumetric reconstructions. We developed a VR volume viewer compatible with both the Oculus Rift and handheld-based head mounted displays (HMDs). We then performed user experiments to validate the approach in a diagnosis environment. In addition, we assessed the subjects' perception of the 3D reconstruction quality, ease of interaction and ergonomics, and also the users opinion on how VR applications can be useful in healthcare. Among other results, we have found a high level of effectiveness of the VR interface in identifying superficial fractures on head CTs.

  14. Piloted Evaluation of Modernized Limited Authority Control Laws in the NASA-Ames Vertical Motion Simulator (VMS)

    NASA Technical Reports Server (NTRS)

    Sahasrabudhe, Vineet; Melkers, Edgar; Faynberg, Alexander; Blanken, Chris L.

    2003-01-01

    The UH-60 BLACK HAWK was designed in the 1970s, when the US Army primarily operated during the day in good visual conditions. Subsequently, the introduction of night-vision goggles increased the BLACK HAWK'S mission effectiveness, but the accident rate also increased. The increased accident rate is strongly tied to increased pilot workload as a result of a degradation in visual cues. Over twenty years of research in helicopter flight control and handling qualities has shown that these degraded handling qualities can be recovered by modifying the response type of the helicopter in low speed flight. Sikorsky Aircraft Corporation initiated a project under the National Rotorcraft Technology Center (NRTC) to develop modern flight control laws while utilizing the existing partial authority Stability Augmentation System (SAS) of the BLACK HAWK. This effort resulted in a set of Modernized Control Laws (MCLAWS) that incorporate rate command and attitude command response types. Sikorsky and the US Army Aeroflightdynamics Directorate (AFDD) conducted a piloted simulation on the NASA-Ames Vertical h4otion Simulator, to assess potential handling qualities and to reduce the risk of subsequent implementation and flight test of these modern control laws on AFDD's EH-60L helicopter. The simulation showed that Attitude Command Attitude Hold control laws in pitch and roll improve handling qualities in the low speed flight regime. These improvements are consistent across a range of mission task elements and for both good and degraded visual environments. The MCLAWS perform better than the baseline UH-60A control laws in the presence of wind and turbulence. Finally, while the improved handling qualities in the pitch and roll axis allow the pilot to pay more attention to the vertical axis and hence altitude performance also improves, it is clear from pilot comments and altitude excursions that the addition of an Altitude Hold function would further reduce workload and improve overall handling qualities of the aircraft.

  15. Magnetic resonance imaging evaluation of adjacent segments after cervical disc arthroplasty: magnet strength and its effect on image quality. Clinical article.

    PubMed

    Antosh, Ivan J; DeVine, John G; Carpenter, Clyde T; Woebkenberg, Brian J; Yoest, Stephen M

    2010-12-01

    Disc arthroplasty is an alternative to fusion following anterior discectomy when treating either cervical radiculopathy or myelopathy. Its theoretical benefits include preservation of the motion segment and the potential prevention of adjacent-segment degeneration. There is a paucity of data regarding the ability to use MR imaging to evaluate the adjacent segments. The purpose of this study was for the authors to introduce open MR imaging as an alternative method in imaging adjacent segments following cervical disc arthroplasty using a Co-Cr implant and to report their preliminary results using this technique. Postoperative cervical MR images were obtained in the first 16 patients in whom the porous coated motion (PCM-V) cervical arthroplasty system was used to treat a single level between C-3 and C-7. Imaging was performed in all 16 patients with a closed 1.5-T unit, and in the final 6 patients it was also performed with an open 0.2-T unit. All images were evaluated by an independent radiologist observer for the ability to visualize the superior endplate, disc space, and inferior endplate at the superior and inferior adjacent levels. Utilizing the 1.5-T magnet to assess the superior adjacent level, the superior endplate, disc space, and inferior endplate could each be visualized less than 50% of the time on sagittal T1- and sagittal and axial T2-weighted images. Similarly, the inferior adjacent level structures were adequately visualized less than 50% of the time, with the exception of slightly improved visualization of the inferior endplate on T1-weighted images (56%). Axial images allowed worse visualization than sagittal images at both the superior and inferior adjacent levels. Utilizing the 0.2-T magnet to assess the superior and inferior adjacent levels, the superior endplate, disc space, and inferior endplate were adequately visualized in 100% of images. Based on the results of this case series, it appears that the strength of the magnet affects the artifact from the Co-Cr endplates. The open 0.2-T MR imaging unit reduces artifact at adjacent levels after cervical disc arthroplasty without a significant reduction in the image quality. Magnetic resonance imaging can be used to evaluate the adjacent segments after disc arthroplasty if magnet strength is addressed, providing another means to assess the long-term efficacy of this novel treatment.

  16. [National survey of blindness and avoidable visual impairment in Honduras].

    PubMed

    Alvarado, Doris; Rivera, Belinda; Lagos, Luis; Ochoa, Mayra; Starkman, Ivette; Castillo, Mariela; Flores, Eduardo; Lansingh, Van C; Limburg, Hans; Silva, Juan Carlos

    2014-11-01

    To determine the prevalence of blindness and visual impairment in Honduras, its causes and the response by the health services to growing demand. A cross-sectional population study was conducted between June and December 2013 using the standard methodology of the Rapid Assessment of Avoidable Blindness. A random sample survey was done in 63 clusters of 50 individuals aged ≥ 50, representative of the country as a whole. Visual acuity (VA) was assessed using a Snellen eye chart, and the condition of the lens and posterior pole was examined by direct ophthalmoscopy. Cataract surgical coverage was calculated and an assessment made of its quality, the causes of VA < 20/60 and the barriers to accessing surgical treatment. A total of 2 999 people were examined (95.2% of the forecast total). Blindness prevalence was 1.9% (confidence interval of 95%: 1.4-2.4%) and 82.2% of these cases were avoidable. The main causes of blindness were unoperated cataracts (59.2%) and glaucoma (21.1%). Uncorrected refraction error was the main cause of severe (19.7%) and moderate (58.6%) visual impairment. Cataract surgical coverage was 75.2%. 62.5% of the eyes operated for cataracts achieved a VA > 20/60 with available correction. The main barriers against cataract surgery were cost (27.7%) and the lack of availability or difficulty of geographical access to the treatment (24.6%). The prevalence of blindness and visual impairment in Honduras is similar to that of other Latin American countries. 67% of cases of blindness could be resolved by improving the response capacity of the ophthalmological services, especially of cataract surgery, improving optician services and incorporating eye care in primary health care.

  17. Impact of audio/visual systems on pediatric sedation in magnetic resonance imaging.

    PubMed

    Lemaire, Colette; Moran, Gerald R; Swan, Hans

    2009-09-01

    To evaluate the use of an audio/visual (A/V) system in pediatric patients as an alternative to sedation in magnetic resonance imaging (MRI) in terms of wait times, image quality, and patient experience. Pediatric MRI examinations from April 8 to August 11, 2008 were compared to those 1 year prior to the installation of the A/V system. Data collected included age, requisition receive date, scan date, and whether sedation was used. A posttest questionnaire was used to evaluate patient experience. Image quality was assessed by two radiologists. Over the 4 months in 2008 there was an increase of 7.2% (115; P < 0.05) of pediatric patients scanned and a decrease of 15.4%, (67; P = 0.32) requiring sedation. The average sedation wait time decreased by 33% (5.8 months) (P < 0.05). Overall, the most positively affected group was the 4-10 years. The questionnaire resulted in 84% of participants expressing a positive reaction to the A/V system. Radiological evaluation revealed no changes in image quality between A/V users and sedates. The A/V system was a successful method to reduce patient motion and obtain a quality diagnostic MRI without the use of sedation in pediatric patients. It provided a safer option, a positive experience, and decreased wait times.

  18. Power profiles and short-term visual performance of soft contact lenses.

    PubMed

    Papas, Eric; Dahms, Anne; Carnt, Nicole; Tahhan, Nina; Ehrmann, Klaus

    2009-04-01

    To investigate the manner in which contemporary soft contact lenses differ in the distribution of optical power within their optic zones and establish if these variations affect the vision of wearers or the prescribing procedure for back vertex power (BVP). By using a Visionix VC 2001 contact lens power analyzer, power profiles were measured across the optic zones of the following contemporary contact lenses ACUVUE 2, ACUVUE ADVANCE, O2OPTIX, NIGHT & DAY and PureVision. Single BVP measures were obtained using a Nikon projection lensometer. Visual performance was assessed in 28 masked subjects who wore each lens type in random order. Measurements taken were high and low contrast visual acuity in normal illumination (250 Cd/m), high contrast acuity in reduced illumination (5 Cd/m), subjective visual quality using a numerical rating scale, and visual satisfaction rating using a Likert scale. Marked differences in the distribution of optical power across the optic zone were evident among the lens types. No significant differences were found for any of the visual performance variables (p > 0.05, analysis of variance with repeated measures and Friedman test). Variations in power profile between contemporary soft lens types exist but do not, in general, result in measurable visual performance differences in the short term, nor do they substantially influence the BVP required for optimal correction.

  19. Randomized Crossover Trial of Silicone Hydrogel Presbyopic Contact Lenses.

    PubMed

    Sivardeen, Ahmed; Laughton, Deborah; Wolffsohn, James S

    2016-02-01

    To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p < 0.001), stereopsis (p < 0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.

  20. Comparison of a hydrogel corneal inlay and monovision laser in situ keratomileusis in presbyopic patients: focus on visual performance and optical quality.

    PubMed

    Verdoorn, Cornelis

    2017-01-01

    To compare the visual performance and optical quality after Raindrop Near Vision Inlay implantation or monovision LASIK for the correction of presbyopia. In this retrospective case-series study, patients previously treated in the nondominant eye with monovision LASIK were compared with patients previously implanted with Raindrop Near Vision Inlay. The study enrolled 16 inlay and 15 monovision LASIK patients. Uncorrected near visual acuity, uncorrected distance visual acuity, binocular stereopsis, patient satisfaction, and patient task performance were assessed. Postoperatively, the mean spherical equivalent was -0.66 D (0.78 SD) for the inlay group and -1.03 D (0.56 SD) for the monovision LASIK group. Monocularly, at uncorrected near distances, 60% of inlay patients and 47% of monovision LASIK patients achieved ≥20/20. Monocularly, at uncorrected far distances, 75% of inlay patients and 40% of monovision LASIK patients achieved ≥20/32 vision. Binocularly, at near distances, 79% of inlay patients and 53% of monovision LASIK patients obtained ≥20/20 vision. All patients achieved ≥20/20 binocularly for distance. On average, inlay patients obtained 98 seconds of arc and monovision LASIK patients obtained 286 seconds of arc for stereopsis. Most (79%) of the inlay patients and 66% of monovision LASIK patients were satisfied with their near vision, while 86% of inlay patients and 67% of monovision LASIK patients were satisfied with their distance vision. Patients receiving corneal inlays demonstrated better near and distance visual acuities, binocular stereopsis, task performance, and satisfaction, when compared to patients treated with monovision LASIK.

  1. A new real-time visual assessment method for faulty movement patterns during a jump-landing task.

    PubMed

    Rabin, Alon; Levi, Ran; Abramowitz, Shai; Kozol, Zvi

    2016-07-01

    Determine the interrater reliability of a new real-time assessment of faulty movement patterns during a jump-landing task. Interrater reliability study. Human movement laboratory. 50 healthy females. Assessment included 6 items which were evaluated from a front and a side view. Two Physical Therapy students used a 9-point scale (0-8) to independently rate the quality of movement as good (0-2), moderate (3-5), or poor (6-8). Interrater reliability was expressed by percent agreement and weighted kappa. One examiner rated the quality of movement of 6 subjects as good, 34 subjects as moderate, and 10 subjects as poor. The second examiner rated the quality of movement of 12 subjects as good, 23 subjects as moderate, and 15 subjects as poor. Percent agreement and weighted kappa (95% confidence interval) were 78% and 0.68 (0.51, 0.85), respectively. A new real-time assessment of faulty movement patterns during jump-landing demonstrated adequate interrater reliability. Further study is warranted to validate this method against a motion analysis system, as well as to establish its predictive validity for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Fidelity assessment of a UH-60A simulation on the NASA Ames vertical motion simulator

    NASA Technical Reports Server (NTRS)

    Atencio, Adolph, Jr.

    1993-01-01

    Helicopter handling qualities research requires that a ground-based simulation be a high-fidelity representation of the actual helicopter, especially over the frequency range of the investigation. This experiment was performed to assess the current capability to simulate the UH-60A Black Hawk helicopter on the Vertical Motion Simulator (VMS) at NASA Ames, to develop a methodology for assessing the fidelity of a simulation, and to find the causes for lack of fidelity. The approach used was to compare the simulation to the flight vehicle for a series of tasks performed in flight and in the simulator. The results show that subjective handling qualities ratings from flight to simulator overlap, and the mathematical model matches the UH-60A helicopter very well over the range of frequencies critical to handling qualities evaluation. Pilot comments, however, indicate a need for improvement in the perceptual fidelity of the simulation in the areas of motion and visual cuing. The methodology used to make the fidelity assessment proved useful in showing differences in pilot work load and strategy, but additional work is needed to refine objective methods for determining causes of lack of fidelity.

  3. Visual Grading and Quality of 1-0 Northern Red Oak Seedlings

    Treesearch

    S.L. Clark; S.E. Scblarbaum; Paul P. Kormanik

    2000-01-01

    Past research has used detailed measurements of various growth characteristics to determine seedling grades and quality of northern red oak nursery stock This study evaluates the effectiveness ofa visual grading process. similar to thosefound in commercial nursery operations, to distinguish high quality seedlings. Northern red oak (Quercus rubra...

  4. Assessing disease stress and modeling yield losses in alfalfa

    NASA Astrophysics Data System (ADS)

    Guan, Jie

    Alfalfa is the most important forage crop in the U.S. and worldwide. Fungal foliar diseases are believed to cause significant yield losses in alfalfa, yet, little quantitative information exists regarding the amount of crop loss. Different fungicides and application frequencies were used as tools to generate a range of foliar disease intensities in Ames and Nashua, IA. Visual disease assessments (disease incidence, disease severity, and percentage defoliation) were obtained weekly for each alfalfa growth cycle (two to three growing cycles per season). Remote sensing assessments were performed using a hand-held, multispectral radiometer to measure the amount and quality of sunlight reflected from alfalfa canopies. Factors such as incident radiation, sun angle, sensor height, and leaf wetness were all found to significantly affect the percentage reflectance of sunlight reflected from alfalfa canopies. The precision of visual and remote sensing assessment methods was quantified. Precision was defined as the intra-rater repeatability and inter-rater reliability of assessment methods. F-tests, slopes, intercepts, and coefficients of determination (R2) were used to compare assessment methods for precision. Results showed that among the three visual disease assessment methods (disease incidence, disease severity, and percentage defoliation), percentage defoliation had the highest intra-rater repeatability and inter-rater reliability. Remote sensing assessment method had better precision than the percentage defoliation assessment method based upon higher intra-rater repeatability and inter-rater reliability. Significant linear relationships between canopy reflectance (810 nm), percentage defoliation and yield were detected using linear regression and percentage reflectance (810 nm) assessments were found to have a stronger relationship with yield than percentage defoliation assessments. There were also significant linear relationships between percentage defoliation, dry weight, percentage reflectance (810 nm), and green leaf area index (GLAI). Percentage reflectance (810 nm) assessments had a stronger relationship with dry weight and green leaf area index than percentage defoliation assessments. Our research conclusively demonstrates that percentage reflectance measurements can be used to nondestructively assess green leaf area index which is a direct measure of plant health and an indirect measure of productivity. This research conclusively demonstrates that remote sensing is superior to visual assessment method to assess alfalfa stress and to model yield and GLAI in the alfalfa foliar disease pathosystem.

  5. Combined visual and semi-quantitative assessment of 123I-FP-CIT SPECT for the diagnosis of dopaminergic neurodegenerative diseases.

    PubMed

    Ueda, Jun; Yoshimura, Hajime; Shimizu, Keiji; Hino, Megumu; Kohara, Nobuo

    2017-07-01

    Visual and semi-quantitative assessments of 123 I-FP-CIT single-photon emission computed tomography (SPECT) are useful for the diagnosis of dopaminergic neurodegenerative diseases (dNDD), including Parkinson's disease, dementia with Lewy bodies, progressive supranuclear palsy, multiple system atrophy, and corticobasal degeneration. However, the diagnostic value of combined visual and semi-quantitative assessment in dNDD remains unclear. Among 239 consecutive patients with a newly diagnosed possible parkinsonian syndrome who underwent 123 I-FP-CIT SPECT in our medical center, 114 patients with a disease duration less than 7 years were diagnosed as dNDD with the established criteria or as non-dNDD according to clinical judgment. We retrospectively examined their clinical characteristics and visual and semi-quantitative assessments of 123 I-FP-CIT SPECT. The striatal binding ratio (SBR) was used as a semi-quantitative measure of 123 I-FP-CIT SPECT. We calculated the sensitivity and specificity of visual assessment alone, semi-quantitative assessment alone, and combined visual and semi-quantitative assessment for the diagnosis of dNDD. SBR was correlated with visual assessment. Some dNDD patients with a normal visual assessment had an abnormal SBR, and vice versa. There was no statistically significant difference between sensitivity of the diagnosis with visual assessment alone and semi-quantitative assessment alone (91.2 vs. 86.8%, respectively, p = 0.29). Combined visual and semi-quantitative assessment demonstrated superior sensitivity (96.7%) to visual assessment (p = 0.03) or semi-quantitative assessment (p = 0.003) alone with equal specificity. Visual and semi-quantitative assessments of 123 I-FP-CIT SPECT are helpful for the diagnosis of dNDD, and combined visual and semi-quantitative assessment shows superior sensitivity with equal specificity.

  6. Physical Activity, Body Composition, and Perceived Quality of Life of Adults with Visual Impairments

    ERIC Educational Resources Information Center

    Holbrook, Elizabeth A.; Caputo, Jennifer L.; Perry, Tara L.; Fuller, Dana K.; Morgan, Don W.

    2009-01-01

    Relatively little is known about the health and fitness of adults with visual impairments. This article documents the physical activity levels and body-composition profiles of young and middle-aged adults with visual impairments and addresses the concomitant effects of these factors on perceived quality of life. (Contains 2 tables.)

  7. Comparison of visual field training for hemianopia with active versus sham transcranial direct cortical stimulation.

    PubMed

    Plow, Ela B; Obretenova, Souzana N; Fregni, Felipe; Pascual-Leone, Alvaro; Merabet, Lotfi B

    2012-01-01

    Vision Restoration Therapy (VRT) aims to improve visual field function by systematically training regions of residual vision associated with the activity of suboptimal firing neurons within the occipital cortex. Transcranial direct current stimulation (tDCS) has been shown to modulate cortical excitability. Assess the possible efficacy of tDCS combined with VRT. The authors conducted a randomized, double-blind, demonstration-of-concept pilot study where participants were assigned to either VRT and tDCS or VRT and sham. The anode was placed over the occipital pole to target both affected and unaffected lobes. One hour training sessions were carried out 3 times per week for 3 months in a laboratory. Outcome measures included objective and subjective changes in visual field, recording of visual fixation performance, and vision-related activities of daily living (ADLs) and quality of life (QOL). Although 12 participants were enrolled, only 8 could be analyzed. The VRT and tDCS group demonstrated significantly greater expansion in visual field and improvement on ADLs compared with the VRT and sham group. Contrary to expectations, subjective perception of visual field change was greater in the VRT and sham group. QOL did not change for either group. The observed changes in visual field were unrelated to compensatory eye movements, as shown with fixation monitoring. The combination of occipital cortical tDCS with visual field rehabilitation appears to enhance visual functional outcomes compared with visual rehabilitation alone. TDCS may enhance inherent mechanisms of plasticity associated with training.

  8. Quality-Related Monitoring and Grading of Granulated Products by Weibull-Distribution Modeling of Visual Images with Semi-Supervised Learning

    PubMed Central

    Liu, Jinping; Tang, Zhaohui; Xu, Pengfei; Liu, Wenzhong; Zhang, Jin; Zhu, Jianyong

    2016-01-01

    The topic of online product quality inspection (OPQI) with smart visual sensors is attracting increasing interest in both the academic and industrial communities on account of the natural connection between the visual appearance of products with their underlying qualities. Visual images captured from granulated products (GPs), e.g., cereal products, fabric textiles, are comprised of a large number of independent particles or stochastically stacking locally homogeneous fragments, whose analysis and understanding remains challenging. A method of image statistical modeling-based OPQI for GP quality grading and monitoring by a Weibull distribution(WD) model with a semi-supervised learning classifier is presented. WD-model parameters (WD-MPs) of GP images’ spatial structures, obtained with omnidirectional Gaussian derivative filtering (OGDF), which were demonstrated theoretically to obey a specific WD model of integral form, were extracted as the visual features. Then, a co-training-style semi-supervised classifier algorithm, named COSC-Boosting, was exploited for semi-supervised GP quality grading, by integrating two independent classifiers with complementary nature in the face of scarce labeled samples. Effectiveness of the proposed OPQI method was verified and compared in the field of automated rice quality grading with commonly-used methods and showed superior performance, which lays a foundation for the quality control of GP on assembly lines. PMID:27367703

  9. Selecting islands and shoals for conservation based on biological and aesthetic criteria

    USGS Publications Warehouse

    Knutson, M.G.; Leopold, D.J.; Smardon, R.C.

    1993-01-01

    Consideration of biological quality has long been an important component of rating areas for conservation. Often these same areas are highly valued by people for aesthetic reasons, creating demands for housing and recreation that may conflict with protection plans for these habitats. Most methods of selecting land for conservation purposes use biological factors alone. For some land areas, analysis of aesthetic qualities is also important in describing the scenic value of undisturbed land. A method for prioritizing small islands and shoals based on both biological and visual quality factors is presented here. The study included 169 undeveloped islands and shoals a??0.8 ha in the Thousand Islands Region of the St. Lawrence River, New York. Criteria such as critical habitat for uncommon plant and animal species were considered together with visual quality and incorporated into a rating system that ranked the islands and shoals according to their priority for conservation management and protection from development. Biological factors were determined based on previous research and a field survey. Visual quality was determined by visual diagnostic criteria developed from public responses to photographs of a sample of islands. Variables such as elevation, soil depth, and type of plant community can be used to classify islands into different categories of visual quality but are unsuccessful in classifying islands into categories of overall biological quality.

  10. Visual grading characteristics and ordinal regression analysis during optimisation of CT head examinations.

    PubMed

    Zarb, Francis; McEntee, Mark F; Rainford, Louise

    2015-06-01

    To evaluate visual grading characteristics (VGC) and ordinal regression analysis during head CT optimisation as a potential alternative to visual grading assessment (VGA), traditionally employed to score anatomical visualisation. Patient images (n = 66) were obtained using current and optimised imaging protocols from two CT suites: a 16-slice scanner at the national Maltese centre for trauma and a 64-slice scanner in a private centre. Local resident radiologists (n = 6) performed VGA followed by VGC and ordinal regression analysis. VGC alone indicated that optimised protocols had similar image quality as current protocols. Ordinal logistic regression analysis provided an in-depth evaluation, criterion by criterion allowing the selective implementation of the protocols. The local radiology review panel supported the implementation of optimised protocols for brain CT examinations (including trauma) in one centre, achieving radiation dose reductions ranging from 24 % to 36 %. In the second centre a 29 % reduction in radiation dose was achieved for follow-up cases. The combined use of VGC and ordinal logistic regression analysis led to clinical decisions being taken on the implementation of the optimised protocols. This improved method of image quality analysis provided the evidence to support imaging protocol optimisation, resulting in significant radiation dose savings. • There is need for scientifically based image quality evaluation during CT optimisation. • VGC and ordinal regression analysis in combination led to better informed clinical decisions. • VGC and ordinal regression analysis led to dose reductions without compromising diagnostic efficacy.

  11. Assessment of the quality of life through the SF-36 questionnaire in patients with chronic nonspecific low back pain

    PubMed Central

    Adorno, Marta Lúcia Guimarães Resende; Brasil-Neto, Joaquim Pereira

    2013-01-01

    The objective of this study was to evaluate the quality of life (QL) with the use of the SF-36 Questionnaire in patients with chronic nonspecific low back pain (CNLBP). Thirty patients with CNLBP were randomly assigned to one of three groups (Iso group (Isostretching), GPR group (Global Postural Reeducation), and the Iso+GPR group. Patients underwent physical therapy assessment with the use of the Vertebral Spine Assessment, the Visual Analog Scale of Pain (VASP), and the SF-36 life quality questionnaire before the first session (first assessment), after three months of treatment (second assessment) and reassessed two months after the final session in the follow-up (third assessment). The results indicated that both physical therapy techniques reduced pain (p<0.001); when the techniques (Iso+GPR) were combined, the reduction in pain was significantly greater; and, in the follow-up assessment, the GPR method was more efficient. As for the QL, physical therapy techniques were effective after the interventions (p<0.001), and the Iso method was more effective when patients were reassessed in the follow-up. We conclude that the physical therapy techniques used in this study were efficient to treat CNLBP in the patients since they reduced pain and increased QL according to the results of the SF-36 questionnaire. Level of Evidence II, Randomized Controlled Clinical Trial. PMID:24453669

  12. Improving Communication During Cardiac ICU Multidisciplinary Rounds Through Visual Display of Patient Daily Goals.

    PubMed

    Justice, Lindsey B; Cooper, David S; Henderson, Carla; Brown, James; Simon, Katherine; Clark, Lindsey; Fleckenstein, Elizabeth; Benscoter, Alexis; Nelson, David P

    2016-07-01

    To improve communication during daily cardiac ICU multidisciplinary rounds. Quality improvement methodology. Twenty-five-bed cardiac ICUs in an academic free-standing pediatric hospital. All patients admitted to the cardiac ICU. Implementation of visual display of patient daily goals through a write-down and read-back process. The Rounds Effectiveness Assessment and Communication Tool was developed based on the previously validated Patient Knowledge Assessment Tool to evaluate comprehension of patient daily goals. Rounds were assessed for each patient by the bedside nurse, nurse practitioner or fellow, and attending physician, and answers were compared to determine percent agreement per day. At baseline, percent agreement for patient goals was only 62%. After initial implementation of the daily goal write-down/read-back process, which was written on paper by the bedside nurse, the Rounds Effectiveness Assessment and Communication Tool survey revealed no improvement. With adaptation of the intervention so goals were written on whiteboards for visual display during rounds, the percent agreement improved to 85%. Families were also asked to complete a survey (1-6 Likert scale) of their satisfaction with rounds and understanding of daily goals before and after the intervention. Family survey results improved from a mean of 4.6-5.7. Parent selection of the best possible score for each question was 19% at baseline and 75% after the intervention. Visual display of patient daily goals via a write-down/read-back process improves comprehension of goals by all team members and improves parent satisfaction. The daily goal whiteboard facilitates consistent development of a comprehensive plan of care for each patient, fosters goal-directed care, and provides a checklist for providers and parents to review throughout the day.

  13. Association of sleep quality in Behcet disease with disease activity, depression, and quality of life in Korean population

    PubMed Central

    Lee, Jimin; Kim, Sung-Soo; Jeong, Hye-Jin; Son, Chang-Nam; Kim, Ji-Min; Cho, Yong-Won; Kim, Sang-Hyon

    2017-01-01

    Background/Aims Sleep disturbance is prime concern in patients with Behcet disease. The purpose of this study was to find out the effects of sleep quality, in Korean patients suffering from Behcet disease. We further investigated the relationship between depression, quality of life and the clinical findings of Behcet disease. Methods The study was performed by the cross-sectional design. Sleep quality was assessed by the Korean version of Pittsburgh sleep quality index (PSQI). Disease activity of Behcet disease was evaluated by Behcet disease current activity form (BDCAF). Depression was assessed by the Korean version of Beck depression inventory second edition (BDI-2). Quality of life was assessed by the Korean version of the Leeds Behcet disease quality of life measure (BDQoL). Results Among the 100 patients studied, 42% reported poor sleep quality (PSQI ≥ 9). These patients have a higher BDI-2, total BDCAF and pain visual analogue scale (VAS) score (p < 0.001, p = 0.022, and p = 0.005). Considering BDCAF, the frequency of genital ulcer was significantly higher (p = 0.01). Behcet was higher in females. The BDQoL was lower in poor sleeper group (p = 0.004 and p < 0.001). Among 7 PSQI components, daytime dysfunction was higher in patients with high disease activity (p = 0.03). Total PSQI score were strongly correlated with BDCAF, BDI-2, BDQoL, and pain VAS score (p = 0.02, p < 0.001, p < 0.001, and p < 0.001, respectively). Conclusions Low sleep quality is directly associated with disease activity, depression, and quality of life in Korean patients with Behcet disease. PMID:28192886

  14. A daily skincare regimen with a unique ceramide and filaggrin formulation rapidly improves chronic xerosis, pruritus, and quality of life in older adults.

    PubMed

    Chang, Anne Lynn S; Chen, Suephy C; Osterberg, Lars; Brandt, Staci; von Grote, Erika C; Meckfessel, Matthew H

    A skin care regimen which significantly improved atopic dermatitis and pruritus was evaluated for its efficacy and acceptability in senior subjects diagnosed with xerosis who also suffer from pruritus. This was an open-label, single-center study, designed to evaluate the daily use of a skin care regimen for 15 days. Assessments were made at baseline, day 8 and day 15 for visual skin dryness, transepidermal water loss (TEWL), hydration, desquamation, subject-perceived itch and quality of life (QoL). Twenty-five subjects, ages 60-73 years, had significantly improved skin visual dryness, hydration, desquamation, itch and QoL at days 8 and 15, relative to baseline (P < .05). TEWL was improved, though not significantly. Subjects expressed a high degree of satisfaction with the results. This regimen provides geriatric patients with an easily incorporated skin routine to help improve a common symptom of aging skin which negatively affects QoL. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Analysis of visual quality improvements provided by known tools for HDR content

    NASA Astrophysics Data System (ADS)

    Kim, Jaehwan; Alshina, Elena; Lee, JongSeok; Park, Youngo; Choi, Kwang Pyo

    2016-09-01

    In this paper, the visual quality of different solutions for high dynamic range (HDR) compression using MPEG test contents is analyzed. We also simulate the method for an efficient HDR compression which is based on statistical property of the signal. The method is compliant with HEVC specification and also easily compatible with other alternative methods which might require HEVC specification changes. It was subjectively tested on commercial TVs and compared with alternative solutions for HDR coding. Subjective visual quality tests were performed using SUHD TVs model which is SAMSUNG JS9500 with maximum luminance up to 1000nit in test. The solution that is based on statistical property shows not only improvement of objective performance but improvement of visual quality compared to other HDR solutions, while it is compatible with HEVC specification.

  16. Utility of double-contrast multi-detector CT scans to assess cartilage thickness after tibial plafond fracture

    PubMed Central

    Thomas, Thaddeus P.; Van Hofwegen, Christopher J.; Anderson, Donald D.; Brown, Thomas D.; Marsh, J. Lawrence

    2010-01-01

    The pathophysiology of post-traumatic osteoarthritis (PTOA) after intra-articular fractures is poorly understood. Pursuit of a better understanding of this disease is complicated by inability to accurately monitor its onset, progression and severity. Common radiographic methods used to assess PTOA do not provide sufficient image quality for precise cartilage measurements. Double-contrast MDCT is an alternative method that may be useful, since it produces high-quality images in normal ankles. The purpose of this study was to assess this technique’s performance in assessing cartilage maintenance in ankles with an intra-articular fracture. Thirty-six tibial plafond fractures were followed over two years, with thirty-one MDCTs being obtained four months after injury, and twenty-two MDCTs after two years. Unfortunately, clinical results with this technique were unreliable due to pathology (presumed arthrofibrosis) and technical problems (pooling of contrast). The arthrofibrosis that developed in many patients inhibited proper joint access and contrast infiltration, although high-quality images were obtained in eleven patients. In this patient subset, in which focal regions of cartilage degeneration could be visualized, thickness could be measured with a high degree of fidelity. While thus useful in selected instances, double-contrast MDCT was too unreliable to be recommended to assess these particular types of injuries. PMID:20634971

  17. Visual outcome and impact on quality of life after surgeries differ in children operated for unilateral and bilateral cataract (Pune study 2011)

    PubMed Central

    Paryani, Mukesh; Khandekar, Rajiv B.; Dole, Kuldeep; Dharmadhikari, Sheetal; Rishikeshi, Nikhil

    2012-01-01

    Background: We compared vision and quality of life (VQL) of children aged 5-15 years and operated for unilateral and bilateral cataract between 2008 and 2010 in western India. Materials and Methods: In this cohort study, ophthalmologists assessed vision, anterior and posterior segment of eyes with cataract. Children completed a functional vision questionnaire (LVP-FVQ). Follow up at 6 months after surgery included the best corrected visual acuity (BCVA), FVQ and eye assessment. The improvement of BCVA and quality of life were compared in group of unilateral and bilateral cataract. Result: A total of 20 (70%) bilateral and 7 (39%) unilateral cataract were operated within 1 month of detection. All 48 eyes with bilateral cataract were congenital and 12 (67%) unilateral cataract were traumatic. Among bilateral group, 27 eyes [56.2% (95% confidence interval (CI) 44.4-72.2)] and in unilateral group 11 eyes [61.1% (95% CI 38.6-83.6)] had vision ≥ 20/60 at 6 months follow up. The visual gain was significantly higher in children who were operated between 1 month and 1 year of detection (adjusted Odds ratio (OR) = 15.6 P = 0.03). Positive impact on VQL in bilateral group was noted in 50%, 27%, and 13% children for subscale of distant vision, near vision, and field of vision, respectively. There was positive impact in these subscales among children with unilateral cataract. Thirty percent eyes with bilateral cataract and 22% of eyes with unilateral cataract improved their vision. Surgery within 1 month of cataract was significant predictor of improved vision (OR = 16.6 P = 0.02). Conclusion: Vision and VQL improved in children with unilateral and bilateral cataract. However, it was better 6 months following surgery in children with bilateral cataract than in children with unilateral cataract. PMID:23439722

  18. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.

    Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic andmore » lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.« less

  19. A Visual Arts Education pedagogical approach for enhancing quality of life for persons with dementia (innovative practice).

    PubMed

    Tietyen, Ann C; Richards, Allan G

    2017-01-01

    A new and innovative pedagogical approach that administers hands-on visual arts activities to persons with dementia based on the field of Visual Arts Education is reported in this paper. The aims of this approach are to enhance cognition and improve quality of life. These aims were explored in a small qualitative study with eight individuals with moderate dementia, and the results are published as a thesis. In this paper, we summarize and report the results of this small qualitative study and expand upon the rationale for the Visual Arts Education pedagogical approach that has shown promise for enhancing cognitive processes and improving quality of life for persons with dementia.

  20. Feasibility of a Semi-computerized Line Bisection Test for Unilateral Visual Neglect Assessment.

    PubMed

    Jee, H; Kim, J; Kim, C; Kim, T; Park, J

    2015-01-01

    Commonly used paper-and-pencil based test modalities for assessing the degree of unilateral visual neglect (ULN) in patients with hemispheric cerebral lesions consume human resources with a significant inter and intra-rater variability. To explore the feasibility of a semi-computerized electronic-pen based ULN assessment system (e-system) to improve assessment quality without altering the conventional user interface. Thirty cognitively healthy participants (HG) and 11 participants diagnosed with right-hemispheric lesion and unilateral visual neglect (NG) were recruited to evaluate the e-system. Line bisection tests (LBT) were repeatedly conducted twice for the inter-rater and intra-rater (reliability) comparisons. The LBT results were assessed by the e-system and the golden standard methods (manual rater assessment). The percent deviation (%), assessment duration (sec), and number of neglected line (each) were evaluated. The inter-rater comparisons of the assessed deviation (%) variable showed excellent interrater reliabilities (CCCs) ranging from .84 (.59 to .95 (p < .001)) to .99 (.90 to .99 (p < .001)) for HG and NG. The Bland Altman mean difference (B-A) plots with bias (95% LOA (limits of agreement)) showed similar agreements between the e-system and the raters ranging from -.04 % (-2.10 to 1.97) to 1.30 % (-2.23 to 4.84) for HG and NG. The effect sizes (ES), which show similarities between the assessment methods, yielded smaller ranges from .01 to .30 for HG and NG. The reliability (test-retest) comparisons showed similar assessment results between the e-system, rater 1, and rater 2. The manual rater assessment time ranging from 5.85 to 6.00 minutes and inter- and intraassessment variations were virtually eliminated with the e-system. The semi-computerized system with the conventional paper-and pencil user-interface showed valid and reliable assessment results. It may be a feasible replacement for the manual rater assessment modality even in a clinical setting.

Top