Image Fusion Algorithms Using Human Visual System in Transform Domain
NASA Astrophysics Data System (ADS)
Vadhi, Radhika; Swamy Kilari, Veera; Samayamantula, Srinivas Kumar
2017-08-01
The endeavor of digital image fusion is to combine the important visual parts from various sources to advance the visibility eminence of the image. The fused image has a more visual quality than any source images. In this paper, the Human Visual System (HVS) weights are used in the transform domain to select appropriate information from various source images and then to attain a fused image. In this process, mainly two steps are involved. First, apply the DWT to the registered source images. Later, identify qualitative sub-bands using HVS weights. Hence, qualitative sub-bands are selected from different sources to form high quality HVS based fused image. The quality of the HVS based fused image is evaluated with general fusion metrics. The results show the superiority among the state-of-the art resolution Transforms (MRT) such as Discrete Wavelet Transform (DWT), Stationary Wavelet Transform (SWT), Contourlet Transform (CT), and Non Sub Sampled Contourlet Transform (NSCT) using maximum selection fusion rule.
Human visual system consistent quality assessment for remote sensing image fusion
NASA Astrophysics Data System (ADS)
Liu, Jun; Huang, Junyi; Liu, Shuguang; Li, Huali; Zhou, Qiming; Liu, Junchen
2015-07-01
Quality assessment for image fusion is essential for remote sensing application. Generally used indices require a high spatial resolution multispectral (MS) image for reference, which is not always readily available. Meanwhile, the fusion quality assessments using these indices may not be consistent with the Human Visual System (HVS). As an attempt to overcome this requirement and inconsistency, this paper proposes an HVS-consistent image fusion quality assessment index at the highest resolution without a reference MS image using Gaussian Scale Space (GSS) technology that could simulate the HVS. The spatial details and spectral information of original and fused images are first separated in GSS, and the qualities are evaluated using the proposed spatial and spectral quality index respectively. The overall quality is determined without a reference MS image by a combination of the proposed two indices. Experimental results on various remote sensing images indicate that the proposed index is more consistent with HVS evaluation compared with other widely used indices that may or may not require reference images.
Infrared dim and small target detecting and tracking method inspired by Human Visual System
NASA Astrophysics Data System (ADS)
Dong, Xiabin; Huang, Xinsheng; Zheng, Yongbin; Shen, Lurong; Bai, Shengjian
2014-01-01
Detecting and tracking dim and small target in infrared images and videos is one of the most important techniques in many computer vision applications, such as video surveillance and infrared imaging precise guidance. Recently, more and more algorithms based on Human Visual System (HVS) have been proposed to detect and track the infrared dim and small target. In general, HVS concerns at least three mechanisms including contrast mechanism, visual attention and eye movement. However, most of the existing algorithms simulate only a single one of the HVS mechanisms, resulting in many drawbacks of these algorithms. A novel method which combines the three mechanisms of HVS is proposed in this paper. First, a group of Difference of Gaussians (DOG) filters which simulate the contrast mechanism are used to filter the input image. Second, a visual attention, which is simulated by a Gaussian window, is added at a point near the target in order to further enhance the dim small target. This point is named as the attention point. Eventually, the Proportional-Integral-Derivative (PID) algorithm is first introduced to predict the attention point of the next frame of an image which simulates the eye movement of human being. Experimental results of infrared images with different types of backgrounds demonstrate the high efficiency and accuracy of the proposed method to detect and track the dim and small targets.
Visual quality analysis for images degraded by different types of noise
NASA Astrophysics Data System (ADS)
Ponomarenko, Nikolay N.; Lukin, Vladimir V.; Ieremeyev, Oleg I.; Egiazarian, Karen O.; Astola, Jaakko T.
2013-02-01
Modern visual quality metrics take into account different peculiarities of the Human Visual System (HVS). One of them is described by the Weber-Fechner law and deals with the different sensitivity to distortions in image fragments with different local mean values (intensity, brightness). We analyze how this property can be incorporated into a metric PSNRHVS- M. It is shown that some improvement of its performance can be provided. Then, visual quality of color images corrupted by three types of i.i.d. noise (pure additive, pure multiplicative, and signal dependent, Poisson) is analyzed. Experiments with a group of observers are carried out for distorted color images created on the basis of TID2008 database. Several modern HVS-metrics are considered. It is shown that even the best metrics are unable to assess visual quality of distorted images adequately enough. The reasons for this deal with the observer's attention to certain objects in the test images, i.e., with semantic aspects of vision, which are worth taking into account in design of HVS-metrics.
Human visual system-based color image steganography using the contourlet transform
NASA Astrophysics Data System (ADS)
Abdul, W.; Carré, P.; Gaborit, P.
2010-01-01
We present a steganographic scheme based on the contourlet transform which uses the contrast sensitivity function (CSF) to control the force of insertion of the hidden information in a perceptually uniform color space. The CIELAB color space is used as it is well suited for steganographic applications because any change in the CIELAB color space has a corresponding effect on the human visual system as is very important for steganographic schemes to be undetectable by the human visual system (HVS). The perceptual decomposition of the contourlet transform gives it a natural advantage over other decompositions as it can be molded with respect to the human perception of different frequencies in an image. The evaluation of the imperceptibility of the steganographic scheme with respect to the color perception of the HVS is done using standard methods such as the structural similarity (SSIM) and CIEDE2000. The robustness of the inserted watermark is tested against JPEG compression.
On Optimizing H. 264/AVC Rate Control by Improving R-D Model and Incorporating HVS Characteristics
NASA Astrophysics Data System (ADS)
Zhu, Zhongjie; Wang, Yuer; Bai, Yongqiang; Jiang, Gangyi
2010-12-01
The state-of-the-art JVT-G012 rate control algorithm of H.264 is improved from two aspects. First, the quadratic rate-distortion (R-D) model is modified based on both empirical observations and theoretical analysis. Second, based on the existing physiological and psychological research findings of human vision, the rate control algorithm is optimized by incorporating the main characteristics of the human visual system (HVS) such as contrast sensitivity, multichannel theory, and masking effect. Experiments are conducted, and experimental results show that the improved algorithm can simultaneously enhance the overall subjective visual quality and improve the rate control precision effectively.
A CNN based neurobiology inspired approach for retinal image quality assessment.
Mahapatra, Dwarikanath; Roy, Pallab K; Sedai, Suman; Garnavi, Rahil
2016-08-01
Retinal image quality assessment (IQA) algorithms use different hand crafted features for training classifiers without considering the working of the human visual system (HVS) which plays an important role in IQA. We propose a convolutional neural network (CNN) based approach that determines image quality using the underlying principles behind the working of the HVS. CNNs provide a principled approach to feature learning and hence higher accuracy in decision making. Experimental results demonstrate the superior performance of our proposed algorithm over competing methods.
No-reference quality assessment based on visual perception
NASA Astrophysics Data System (ADS)
Li, Junshan; Yang, Yawei; Hu, Shuangyan; Zhang, Jiao
2014-11-01
The visual quality assessment of images/videos is an ongoing hot research topic, which has become more and more important for numerous image and video processing applications with the rapid development of digital imaging and communication technologies. The goal of image quality assessment (IQA) algorithms is to automatically assess the quality of images/videos in agreement with human quality judgments. Up to now, two kinds of models have been used for IQA, namely full-reference (FR) and no-reference (NR) models. For FR models, IQA algorithms interpret image quality as fidelity or similarity with a perfect image in some perceptual space. However, the reference image is not available in many practical applications, and a NR IQA approach is desired. Considering natural vision as optimized by the millions of years of evolutionary pressure, many methods attempt to achieve consistency in quality prediction by modeling salient physiological and psychological features of the human visual system (HVS). To reach this goal, researchers try to simulate HVS with image sparsity coding and supervised machine learning, which are two main features of HVS. A typical HVS captures the scenes by sparsity coding, and uses experienced knowledge to apperceive objects. In this paper, we propose a novel IQA approach based on visual perception. Firstly, a standard model of HVS is studied and analyzed, and the sparse representation of image is accomplished with the model; and then, the mapping correlation between sparse codes and subjective quality scores is trained with the regression technique of least squaresupport vector machine (LS-SVM), which gains the regressor that can predict the image quality; the visual metric of image is predicted with the trained regressor at last. We validate the performance of proposed approach on Laboratory for Image and Video Engineering (LIVE) database, the specific contents of the type of distortions present in the database are: 227 images of JPEG2000, 233 images of JPEG, 174 images of White Noise, 174 images of Gaussian Blur, 174 images of Fast Fading. The database includes subjective differential mean opinion score (DMOS) for each image. The experimental results show that the proposed approach not only can assess many kinds of distorted images quality, but also exhibits a superior accuracy and monotonicity.
NASA Astrophysics Data System (ADS)
Szu, Harold; Hsu, Charles; Landa, Joseph; Cha, Jae H.; Krapels, Keith A.
2015-05-01
How can we design cameras that image selectively in Full Electro-Magnetic (FEM) spectra? Without selective imaging, we cannot use, for example, ordinary tourist cameras to see through fire, smoke, or other obscurants contributing to creating a Visually Degraded Environment (VDE). This paper addresses a possible new design of selective-imaging cameras at firmware level. The design is consistent with physics of the irreversible thermodynamics of Boltzmann's molecular entropy. It enables imaging in appropriate FEM spectra for sensing through the VDE, and displaying in color spectra for Human Visual System (HVS). We sense within the spectra the largest entropy value of obscurants such as fire, smoke, etc. Then we apply a smart firmware implementation of Blind Sources Separation (BSS) to separate all entropy sources associated with specific Kelvin temperatures. Finally, we recompose the scene using specific RGB colors constrained by the HVS, by up/down shifting Planck spectra at each pixel and time.
Perceptual color difference metric including a CSF based on the perception threshold
NASA Astrophysics Data System (ADS)
Rosselli, Vincent; Larabi, Mohamed-Chaker; Fernandez-Maloigne, Christine
2008-01-01
The study of the Human Visual System (HVS) is very interesting to quantify the quality of a picture, to predict which information will be perceived on it, to apply adapted tools ... The Contrast Sensitivity Function (CSF) is one of the major ways to integrate the HVS properties into an imaging system. It characterizes the sensitivity of the visual system to spatial and temporal frequencies and predicts the behavior for the three channels. Common constructions of the CSF have been performed by estimating the detection threshold beyond which it is possible to perceive a stimulus. In this work, we developed a novel approach for spatio-chromatic construction based on matching experiments to estimate the perception threshold. It consists in matching the contrast of a test stimulus with that of a reference one. The obtained results are quite different in comparison with the standard approaches as the chromatic CSFs have band-pass behavior and not low pass. The obtained model has been integrated in a perceptual color difference metric inspired by the s-CIELAB. The metric is then evaluated with both objective and subjective procedures.
Perceptual Contrast Enhancement with Dynamic Range Adjustment
Zhang, Hong; Li, Yuecheng; Chen, Hao; Yuan, Ding; Sun, Mingui
2013-01-01
Recent years, although great efforts have been made to improve its performance, few Histogram equalization (HE) methods take human visual perception (HVP) into account explicitly. The human visual system (HVS) is more sensitive to edges than brightness. This paper proposes to take use of this nature intuitively and develops a perceptual contrast enhancement approach with dynamic range adjustment through histogram modification. The use of perceptual contrast connects the image enhancement problem with the HVS. To pre-condition the input image before the HE procedure is implemented, a perceptual contrast map (PCM) is constructed based on the modified Difference of Gaussian (DOG) algorithm. As a result, the contrast of the image is sharpened and high frequency noise is suppressed. A modified Clipped Histogram Equalization (CHE) is also developed which improves visual quality by automatically detecting the dynamic range of the image with improved perceptual contrast. Experimental results show that the new HE algorithm outperforms several state-of-the-art algorithms in improving perceptual contrast and enhancing details. In addition, the new algorithm is simple to implement, making it suitable for real-time applications. PMID:24339452
Fault Diagnosis for Rolling Bearings under Variable Conditions Based on Visual Cognition
Cheng, Yujie; Zhou, Bo; Lu, Chen; Yang, Chao
2017-01-01
Fault diagnosis for rolling bearings has attracted increasing attention in recent years. However, few studies have focused on fault diagnosis for rolling bearings under variable conditions. This paper introduces a fault diagnosis method for rolling bearings under variable conditions based on visual cognition. The proposed method includes the following steps. First, the vibration signal data are transformed into a recurrence plot (RP), which is a two-dimensional image. Then, inspired by the visual invariance characteristic of the human visual system (HVS), we utilize speed up robust feature to extract fault features from the two-dimensional RP and generate a 64-dimensional feature vector, which is invariant to image translation, rotation, scaling variation, etc. Third, based on the manifold perception characteristic of HVS, isometric mapping, a manifold learning method that can reflect the intrinsic manifold embedded in the high-dimensional space, is employed to obtain a low-dimensional feature vector. Finally, a classical classification method, support vector machine, is utilized to realize fault diagnosis. Verification data were collected from Case Western Reserve University Bearing Data Center, and the experimental result indicates that the proposed fault diagnosis method based on visual cognition is highly effective for rolling bearings under variable conditions, thus providing a promising approach from the cognitive computing field. PMID:28772943
NASA Astrophysics Data System (ADS)
Yao, Juncai; Liu, Guizhong
2017-03-01
In order to achieve higher image compression ratio and improve visual perception of the decompressed image, a novel color image compression scheme based on the contrast sensitivity characteristics of the human visual system (HVS) is proposed. In the proposed scheme, firstly the image is converted into the YCrCb color space and divided into sub-blocks. Afterwards, the discrete cosine transform is carried out for each sub-block, and three quantization matrices are built to quantize the frequency spectrum coefficients of the images by combining the contrast sensitivity characteristics of HVS. The Huffman algorithm is used to encode the quantized data. The inverse process involves decompression and matching to reconstruct the decompressed color image. And simulations are carried out for two color images. The results show that the average structural similarity index measurement (SSIM) and peak signal to noise ratio (PSNR) under the approximate compression ratio could be increased by 2.78% and 5.48%, respectively, compared with the joint photographic experts group (JPEG) compression. The results indicate that the proposed compression algorithm in the text is feasible and effective to achieve higher compression ratio under ensuring the encoding and image quality, which can fully meet the needs of storage and transmission of color images in daily life.
Optimum viewing distance for target acquisition
NASA Astrophysics Data System (ADS)
Holst, Gerald C.
2015-05-01
Human visual system (HVS) "resolution" (a.k.a. visual acuity) varies with illumination level, target characteristics, and target contrast. For signage, computer displays, cell phones, and TVs a viewing distance and display size are selected. Then the number of display pixels is chosen such that each pixel subtends 1 min-1. Resolution of low contrast targets is quite different. It is best described by Barten's contrast sensitivity function. Target acquisition models predict maximum range when the display pixel subtends 3.3 min-1. The optimum viewing distance is nearly independent of magnification. Noise increases the optimum viewing distance.
Effective Multifocus Image Fusion Based on HVS and BP Neural Network
Yang, Yong
2014-01-01
The aim of multifocus image fusion is to fuse the images taken from the same scene with different focuses to obtain a resultant image with all objects in focus. In this paper, a novel multifocus image fusion method based on human visual system (HVS) and back propagation (BP) neural network is presented. Three features which reflect the clarity of a pixel are firstly extracted and used to train a BP neural network to determine which pixel is clearer. The clearer pixels are then used to construct the initial fused image. Thirdly, the focused regions are detected by measuring the similarity between the source images and the initial fused image followed by morphological opening and closing operations. Finally, the final fused image is obtained by a fusion rule for those focused regions. Experimental results show that the proposed method can provide better performance and outperform several existing popular fusion methods in terms of both objective and subjective evaluations. PMID:24683327
An Alternative Origin for Hypervelocity Stars
NASA Astrophysics Data System (ADS)
Abadi, Mario G.; Navarro, Julio F.; Steinmetz, Matthias
2009-02-01
Halo stars with unusually high radial velocity (hypervelocity stars, or HVS) are thought to be stars unbound to the Milky Way that originate from the gravitational interaction of stellar systems with the supermassive black hole at the Galactic center. We examine the latest HVS compilation and find peculiarities that are unexpected in this black hole ejection scenario. For example, a large fraction of HVS cluster around the constellation of Leo and share a common travel time of ~100-200 Myr. Furthermore, their velocities are not really extreme if, as suggested by recent galaxy formation models, the Milky Way is embedded within a 2.5 × 1012 h -1 M sun dark halo with virial velocity of ~220 km s-1. In this case, the escape velocity at ~50 kpc would be ~600 km s-1, and very few HVS would be truly unbound. We use numerical simulations to show that disrupting dwarf galaxies may contribute halo stars with velocities up to and sometimes exceeding the nominal escape speed of the system. These stars are arranged in a thinly collimated outgoing "tidal tail" stripped from the dwarf during its latest pericentric passage. We speculate that some HVS may, therefore, be tidal debris from a dwarf recently disrupted near the center of the Galaxy. In this interpretation, the angular clustering of HVS results because, from our perspective, the tail is seen nearly "end on," whereas the common travel time simply reflects the fact that these stars were stripped simultaneously from the dwarf during a single pericentric passage. This proposal is eminently falsifiable, since it makes a number of predictions which are distinct from the black hole ejection mechanism and which should be testable with improved HVS datasets.
Highly divergent hepaciviruses from African cattle.
Corman, Victor Max; Grundhoff, Adam; Baechlein, Christine; Fischer, Nicole; Gmyl, Anatoly; Wollny, Robert; Dei, Dickson; Ritz, Daniel; Binger, Tabea; Adankwah, Ernest; Marfo, Kwadwo Sarfo; Annison, Lawrence; Annan, Augustina; Adu-Sarkodie, Yaw; Oppong, Samuel; Becher, Paul; Drosten, Christian; Drexler, Jan Felix
2015-06-01
The hepatitis C virus (HCV; genus Hepacivirus) is a highly relevant human pathogen. Unique hepaciviruses (HV) were discovered recently in animal hosts. The direct ancestor of HCV has not been found, but the genetically most closely related animal HVs exist in horses. To investigate whether other peridomestic animals also carry HVs, we analyzed sera from Ghanaian cattle for HVs by reverse transcription-PCR (RT-PCR). Nine of 106 specimens from different sampling sites contained HV RNA (8.5%) at median viral loads of 1.6 × 10(5) copies/ml. Infection seemed unrelated to cattle age and gender. Near-full-genome sequencing of five representative viruses confirmed taxonomic classifications. Cattle HVs formed two distinct phylogenetic lineages that differed by up to 17.7% on the nucleotide level in the polyprotein-encoding region, suggesting cocirculation of different virus subtypes. A conserved microRNA122-binding site in the 5' internal ribosomal entry site suggested liver tropism of cattle HVs. Phylogenetic analyses suggested the circulation of HVs in cattle for several centuries. Cattle HVs were genetically highly divergent from all other HVs, including HCV. HVs from genetically related equine and bovine hosts were not monophyletic, corroborating host shifts during the evolution of the genus Hepacivirus. Similar to equine HVs, the genetic diversity of cattle HVs was low compared to that of HCV genotypes. This suggests an influence of the human-modified ecology of peridomestic animals on virus diversity. Further studies should investigate the occurrence of cattle HVs in other geographic areas and breeds, virus pathogenicity in cattle, and the potential exposure of human risk groups, such as farmers, butchers, and abattoir workers. HCV (genus Hepacivirus) is a major human pathogen, causing liver failure and cancer. Unique hepaciviruses (HVs) were discovered over the last few years in animals, but the direct ancestor of HCV has not been found. The animal HV most closely related to HCV so far originated from horses, suggesting that other livestock animals also harbor HVs. Therefore, we investigated African cattle and discovered previously unknown HVs at high prevalence and viral loads. Because of the agricultural importance of cattle, it may be relevant to investigate HV pathogenicity. The frequent exposure of humans to cattle also may warrant investigations of the zoonotic potential of these viruses. Evolutionary analyses suggested that cattle HVs have existed for centuries. Despite the genetic relatedness of their animal hosts, HVs from cattle and horses were not phylogenetically related, corroborating frequent host shifts during the evolution of the genus Hepacivirus. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Visual fatigue modeling for stereoscopic video shot based on camera motion
NASA Astrophysics Data System (ADS)
Shi, Guozhong; Sang, Xinzhu; Yu, Xunbo; Liu, Yangdong; Liu, Jing
2014-11-01
As three-dimensional television (3-DTV) and 3-D movie become popular, the discomfort of visual feeling limits further applications of 3D display technology. The cause of visual discomfort from stereoscopic video conflicts between accommodation and convergence, excessive binocular parallax, fast motion of objects and so on. Here, a novel method for evaluating visual fatigue is demonstrated. Influence factors including spatial structure, motion scale and comfortable zone are analyzed. According to the human visual system (HVS), people only need to converge their eyes to the specific objects for static cameras and background. Relative motion should be considered for different camera conditions determining different factor coefficients and weights. Compared with the traditional visual fatigue prediction model, a novel visual fatigue predicting model is presented. Visual fatigue degree is predicted using multiple linear regression method combining with the subjective evaluation. Consequently, each factor can reflect the characteristics of the scene, and the total visual fatigue score can be indicated according to the proposed algorithm. Compared with conventional algorithms which ignored the status of the camera, our approach exhibits reliable performance in terms of correlation with subjective test results.
Generalized watermarking attack based on watermark estimation and perceptual remodulation
NASA Astrophysics Data System (ADS)
Voloshynovskiy, Sviatoslav V.; Pereira, Shelby; Herrigel, Alexander; Baumgartner, Nazanin; Pun, Thierry
2000-05-01
Digital image watermarking has become a popular technique for authentication and copyright protection. For verifying the security and robustness of watermarking algorithms, specific attacks have to be applied to test them. In contrast to the known Stirmark attack, which degrades the quality of the image while destroying the watermark, this paper presents a new approach which is based on the estimation of a watermark and the exploitation of the properties of Human Visual System (HVS). The new attack satisfies two important requirements. First, image quality after the attack as perceived by the HVS is not worse than the quality of the stego image. Secondly, the attack uses all available prior information about the watermark and cover image statistics to perform the best watermark removal or damage. The proposed attack is based on a stochastic formulation of the watermark removal problem, considering the embedded watermark as additive noise with some probability distribution. The attack scheme consists of two main stages: (1) watermark estimation and partial removal by a filtering based on a Maximum a Posteriori (MAP) approach; (2) watermark alteration and hiding through addition of noise to the filtered image, taking into account the statistics of the embedded watermark and exploiting HVS characteristics. Experiments on a number of real world and computer generated images show the high efficiency of the proposed attack against known academic and commercial methods: the watermark is completely destroyed in all tested images without altering the image quality. The approach can be used against watermark embedding schemes that operate either in coordinate domain, or transform domains like Fourier, DCT or wavelet.
HVS: an image-based approach for constructing virtual environments
NASA Astrophysics Data System (ADS)
Zhang, Maojun; Zhong, Li; Sun, Lifeng; Li, Yunhao
1998-09-01
Virtual Reality Systems can construct virtual environment which provide an interactive walkthrough experience. Traditionally, walkthrough is performed by modeling and rendering 3D computer graphics in real-time. Despite the rapid advance of computer graphics technique, the rendering engine usually places a limit on scene complexity and rendering quality. This paper presents a approach which uses the real-world image or synthesized image to comprise a virtual environment. The real-world image or synthesized image can be recorded by camera, or synthesized by off-line multispectral image processing for Landsat TM (Thematic Mapper) Imagery and SPOT HRV imagery. They are digitally warped on-the-fly to simulate walking forward/backward, to left/right and 360-degree watching around. We have developed a system HVS (Hyper Video System) based on these principles. HVS improves upon QuickTime VR and Surround Video in the walking forward/backward.
Hyperventilation syndrome in adolescents with and without asthma.
D'Alba, Irene; Carloni, Ines; Ferrante, Anna Lisa; Gesuita, Rosaria; Palazzi, Maria Laura; de Benedictis, Fernando Maria
2015-12-01
Data on the prevalence of hyperventilation syndrome (HVS) in adolescents are scanty. To determine the prevalence of HVS in a population of adolescents with and without asthma, and to verify whether HVS was related to asthma activity. A population of adolescents was asked to self-complete a questionnaire, including the Nijmegen questionnaire to assess HVS, and a standardized asthma questionnaire. Seven hundred and sixty questionnaires were suitable for analysis. One hundred and twenty subjects (15.8%) were classified as asthmatic. Forty-seven subjects (6.2%) had a Nijmegen score ≥ 23, which was suggestive of HVS. Symptoms indicative of HVS were ten times more common in subjects with asthma (25%) than in those without asthma (2.5%). Nijmegen score was significantly higher in subjects with lifetime asthma (P < 0.001), current episodic asthma (P < 0.05) and current active asthma (P < 0.001) than in those with no asthma. In the whole population, girls presented HVS more frequently than boys (P < 0.001). There was a significant effect of gender (females, OR 3.2) and status of asthma (lifetime asthma, OR 11.2; current episodic asthma, OR 8.9; current active asthma, OR 41.5) on the probability of suffering from HVS. The prevalence of symptoms indicative of HVS in an unselected population of adolescents was relatively high. Symptoms were more common in girls and in subjects with asthma, and there was a significant effect of asthma activity on the probability of suffering from HVS. Further studies need to be performed in order to validate a screening tool for HVS in both adolescents and asthmatic subjects. © 2014 Wiley Periodicals, Inc.
Yang, Chen; Ge, Shun-Nan; Zhang, Jia-Rui; Chen, Lei; Yan, Zhi-Qiang; Heng, Li-Jun; Zhao, Tian-Zhi; Li, Wei-Xin; Jia, Dong; Zhu, Jun-Ling; Gao, Guo-Dong
2013-01-01
High-voltage spindles (HVSs) have been reported to appear spontaneously and widely in the cortical-basal ganglia networks of rats. Our previous study showed that dopamine depletion can significantly increase the power and coherence of HVSs in the globus pallidus (GP) and motor cortex of freely moving rats. However, it is unclear whether dopamine regulates HVS activity by acting on dopamine D₁-like receptors or D₂-like receptors. We employed local-field potential and electrocorticogram methods to simultaneously record the oscillatory activities in the GP and primary motor cortex (M1) in freely moving rats following systemic administration of dopamine receptor antagonists or saline. The results showed that the dopamine D₂-like receptor antagonists, raclopride and haloperidol, significantly increased the number and duration of HVSs, and the relative power associated with HVS activity in the GP and M1 cortex. Coherence values for HVS activity between the GP and M1 cortex area were also significantly increased by dopamine D₂-like receptor antagonists. On the contrary, the selective dopamine D₁-like receptor antagonist, SCH23390, had no significant effect on the number, duration, or relative power of HVSs, or HVS-related coherence between M1 and GP. In conclusion, dopamine D₂-like receptors, but not D₁-like receptors, were involved in HVS regulation. This supports the important role of dopamine D₂-like receptors in the regulation of HVSs. An siRNA knock-down experiment on the striatum confirmed our conclusion.
Perceptual Fidelity for Digital Color Imagery
1996-12-01
34Margini Quasi-percettivi in campi con Stimolazione Omogenea," Rivista di Psicologia , 49: 7 -30 (1955). English translation by Walter Gerbino (1987) "Quasi...Simple achromatic HVS model ............................... 37 7 . "More anatomically correct" HVS model [37]. ....................... 38 8. Illusory...hue, saturation, and luminance form 7 a polar coordinate system. While this arrangement provides a psychophysical measurement of unit differences in hue
Development of an adaptive bilateral filter for evaluating color image difference
NASA Astrophysics Data System (ADS)
Wang, Zhaohui; Hardeberg, Jon Yngve
2012-04-01
Spatial filtering, which aims to mimic the contrast sensitivity function (CSF) of the human visual system (HVS), has previously been combined with color difference formulae for measuring color image reproduction errors. These spatial filters attenuate imperceptible information in images, unfortunately including high frequency edges, which are believed to be crucial in the process of scene analysis by the HVS. The adaptive bilateral filter represents a novel approach, which avoids the undesirable loss of edge information introduced by CSF-based filtering. The bilateral filter employs two Gaussian smoothing filters in different domains, i.e., spatial domain and intensity domain. We propose a method to decide the parameters, which are designed to be adaptive to the corresponding viewing conditions, and the quantity and homogeneity of information contained in an image. Experiments and discussions are given to support the proposal. A series of perceptual experiments were conducted to evaluate the performance of our approach. The experimental sample images were reproduced with variations in six image attributes: lightness, chroma, hue, compression, noise, and sharpness/blurriness. The Pearson's correlation values between the model-predicted image difference and the observed difference were employed to evaluate the performance, and compare it with that of spatial CIELAB and image appearance model.
Privacy-Aware Image Encryption Based on Logistic Map and Data Hiding
NASA Astrophysics Data System (ADS)
Sun, Jianglin; Liao, Xiaofeng; Chen, Xin; Guo, Shangwei
The increasing need for image communication and storage has created a great necessity for securely transforming and storing images over a network. Whereas traditional image encryption algorithms usually consider the security of the whole plain image, region of interest (ROI) encryption schemes, which are of great importance in practical applications, protect the privacy regions of plain images. Existing ROI encryption schemes usually adopt approximate techniques to detect the privacy region and measure the quality of encrypted images; however, their performance is usually inconsistent with a human visual system (HVS) and is sensitive to statistical attacks. In this paper, we propose a novel privacy-aware ROI image encryption (PRIE) scheme based on logistical mapping and data hiding. The proposed scheme utilizes salient object detection to automatically, adaptively and accurately detect the privacy region of a given plain image. After private pixels have been encrypted using chaotic cryptography, the significant bits are embedded into the nonprivacy region of the plain image using data hiding. Extensive experiments are conducted to illustrate the consistency between our automatic ROI detection and HVS. Our experimental results also demonstrate that the proposed scheme exhibits satisfactory security performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flaherty, Julia E.; Glissmeyer, John A.
2015-03-18
Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilutionmore » system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.« less
PSQM-based RR and NR video quality metrics
NASA Astrophysics Data System (ADS)
Lu, Zhongkang; Lin, Weisi; Ong, Eeping; Yang, Xiaokang; Yao, Susu
2003-06-01
This paper presents a new and general concept, PQSM (Perceptual Quality Significance Map), to be used in measuring the visual distortion. It makes use of the selectivity characteristic of HVS (Human Visual System) that it pays more attention to certain area/regions of visual signal due to one or more of the following factors: salient features in image/video, cues from domain knowledge, and association of other media (e.g., speech or audio). PQSM is an array whose elements represent the relative perceptual-quality significance levels for the corresponding area/regions for images or video. Due to its generality, PQSM can be incorporated into any visual distortion metrics: to improve effectiveness or/and efficiency of perceptual metrics; or even to enhance a PSNR-based metric. A three-stage PQSM estimation method is also proposed in this paper, with an implementation of motion, texture, luminance, skin-color and face mapping. Experimental results show the scheme can improve the performance of current image/video distortion metrics.
Magnetic resonance volumetry of the hippocampus in familial spontaneous epileptic cats.
Mizoguchi, Shunta; Hasegawa, Daisuke; Kuwabara, Takayuki; Hamamoto, Yuji; Ogawa, Fukie; Fujiwara, Aki; Matsuki, Naoaki; Fujita, Michio
2014-12-01
A strain of familial spontaneous epileptic cats (FSECs) with typical limbic seizures was identified in 2010. The electroencephalographic features suggested that an epileptogenic zone is present in the mesial temporal structures (i.e., amygdala and/or hippocampus). In this study, visual evaluations and quantitative analyses were performed by using 3D MR hippocampal volumetry in comparing FSECs with age-matched controls. Visual hippocampal asymmetries were seen in 8 of 14 (57.1%) FSECs. The FSEC group showed a significantly higher asymmetric ratio (4.15%) than the control group (0.99%). The smaller side of hippocampal volume (HV) (0.206 cm(3)) in FSECs was significantly smaller than the mean HV in controls (0.227 cm(3)). However, the means of left and right HVs and total HVs in FSECs showed no differences because the laterality of hippocampal atrophy was different in each individual. Therefore, since FSECs represent a true model of spontaneous epilepsy, hippocampal volumetry should be evaluated in each individual as well as in human patients. The significant asymmetry of HV suggests the potential for hippocampal atrophy in FSECs. Copyright © 2014 Elsevier B.V. All rights reserved.
Inverse Tone Mapping Based upon Retina Response
Huo, Yongqing; Yang, Fan; Brost, Vincent
2014-01-01
The development of high dynamic range (HDR) display arouses the research of inverse tone mapping methods, which expand dynamic range of the low dynamic range (LDR) image to match that of HDR monitor. This paper proposed a novel physiological approach, which could avoid artifacts occurred in most existing algorithms. Inspired by the property of the human visual system (HVS), this dynamic range expansion scheme performs with a low computational complexity and a limited number of parameters and obtains high-quality HDR results. Comparisons with three recent algorithms in the literature also show that the proposed method reveals more important image details and produces less contrast loss and distortion. PMID:24744678
High-voltage electroencephalogram spindles in rats, aging and 5-HT2 antagonism.
Moyanova, S; Kortenska, L; Kirov, R
1998-03-09
We examined the effects of serotonin-2 (5-hydroxytryptamine-2, 5-HT2) receptor antagonists on the so-called high-voltage spindles (HVS, electroencephalographic patterns, characterized by large amplitude rhythmic waves mainly in the alpha band), recorded from the frontal cortex of young, middle-aged and old freely-moving rats during waking immobility. The study was based on the assumption that the effects of 5-HT2 receptor antagonists on the HVS activity depend on the age of rats, because there is evidence for an age-related decrease in the 5-HT2 binding sites density. Four parameters of the electroencephalogram (EEG) were used to characterize the HVS activity: the square root-transformed EEG peak power in the alpha band, the frequency corresponding to this peak (both measured from the EEG power spectra using the fast Fourier transform), the HVS mean duration, and the HVS incidence (both measured from the EEG records). The EEG parameters were analyzed after i.p. administration of three 5-HT2 receptor antagonists: ketanserin, ritanserin and cyproheptadine. In young rats, the three drugs increased the alpha power, but did not change the alpha peak-corresponding frequency. Ketanserin and ritanserin did not change the HVS mean duration and HVS incidence, while cyproheptadine increased both these parameters in young rats. In middle-aged and old untreated rats, the HVS activity was significantly increased. The three 5-HT2 antagonists did not change the HVS activity in aged rats, which could be due to age-related suppression of the 5-HT2 receptor functions. Copyright 1998 Elsevier Science B.V.
A Double-function Digital Watermarking Algorithm Based on Chaotic System and LWT
NASA Astrophysics Data System (ADS)
Yuxia, Zhao; Jingbo, Fan
A double- function digital watermarking technology is studied and a double-function digital watermarking algorithm of colored image is presented based on chaotic system and the lifting wavelet transformation (LWT).The algorithm has realized the double aims of the copyright protection and the integrity authentication of image content. Making use of feature of human visual system (HVS), the watermark image is embedded into the color image's low frequency component and middle frequency components by different means. The algorithm has great security by using two kinds chaotic mappings and Arnold to scramble the watermark image at the same time. The algorithm has good efficiency by using LWT. The emulation experiment indicates the algorithm has great efficiency and security, and the effect of concealing is really good.
Ipsiroglu, Osman S; Hung, Yi-Hsuan Amy; Chan, Forson; Ross, Michelle L; Veer, Dorothee; Soo, Sonja; Ho, Gloria; Berger, Mai; McAllister, Graham; Garn, Heinrich; Kloesch, Gerhard; Barbosa, Adriano Vilela; Stockler, Sylvia; McKellin, William; Vatikiotis-Bateson, Eric
2015-01-01
Advanced video technology is available for sleep-laboratories. However, low-cost equipment for screening in the home setting has not been identified and tested, nor has a methodology for analysis of video recordings been suggested. We investigated different combinations of hardware/software for home-videosomnography (HVS) and established a process for qualitative and quantitative analysis of HVS-recordings. A case vignette (HVS analysis for a 5.5-year-old girl with major insomnia and several co-morbidities) demonstrates how methodological considerations were addressed and how HVS added value to clinical assessment. We suggest an "ideal set of hardware/software" that is reliable, affordable (∼$500) and portable (=2.8 kg) to conduct non-invasive HVS, which allows time-lapse analyses. The equipment consists of a net-book, a camera with infrared optics, and a video capture device. (1) We present an HVS-analysis protocol consisting of three steps of analysis at varying replay speeds: (a) basic overview and classification at 16× normal speed; (b) second viewing and detailed descriptions at 4-8× normal speed, and (c) viewing, listening, and in-depth descriptions at real-time speed. (2) We also present a custom software program that facilitates video analysis and note-taking (Annotator(©)), and Optical Flow software that automatically quantifies movement for internal quality control of the HVS-recording. The case vignette demonstrates how the HVS-recordings revealed the dimension of insomnia caused by restless legs syndrome, and illustrated the cascade of symptoms, challenging behaviors, and resulting medications. The strategy of using HVS, although requiring validation and reliability testing, opens the floor for a new "observational sleep medicine," which has been useful in describing discomfort-related behavioral movement patterns in patients with communication difficulties presenting with challenging/disruptive sleep/wake behaviors.
The role of green fluorescent protein (GFP) in transgenic plants to reduce gene silencing phenomena.
El-Shemy, Hany A; Khalafalla, Mutasim M; Ishimoto, Masao
2009-01-01
The green fluorescent protein (GFP) of jellyfish (Aequorea victoria) has significant advantages over other reporter genes, because expression can be detected in living cells without any substrates. Recently, epigenetic phenomena are important to consider in plant biotechnology experiments for elucidate unknown mechanism. Therefore, soybean immature cotyledons were generated embryogenesis cells and engineered with two different gene constructs (pHV and pHVS) using gene gun method. Both constructs contain a gene conferring resistance to hygromycin (hpt) as a selective marker and a modified glycinin (11S globulin) gene (V3-1) as a target. However, sGFP(S65T) as a reporter gene was used only in pHVS as a reporter gene for study the relation between using sGFP(S65T) and gene silencing phenomena. Fluorescence microscopic was used for screening after the selection of hygromycin, identified clearly the expression of sGFP(S65T) in the transformed soybean embryos bombarded with the pHVS construct. Protein analysis was used to detect gene expression overall seeds using SDS-PAGE. Percentage of gene down regulation was highly in pHV construct compared with pHVS. Thus, sGFP(S65T ) as a reporter gene in vector system may be play useful role for transgenic evaluation and avoid gene silencing in plants for the benefit of plant transformation system.
Expression profiles of urbilaterian genes uniquely shared between honey bee and vertebrates
Matsui, Toshiaki; Yamamoto, Toshiyuki; Wyder, Stefan; Zdobnov, Evgeny M; Kadowaki, Tatsuhiko
2009-01-01
Background Large-scale comparison of metazoan genomes has revealed that a significant fraction of genes of the last common ancestor of Bilateria (Urbilateria) is lost in each animal lineage. This event could be one of the underlying mechanisms involved in generating metazoan diversity. However, the present functions of these ancient genes have not been addressed extensively. To understand the functions and evolutionary mechanisms of such ancient Urbilaterian genes, we carried out comprehensive expression profile analysis of genes shared between vertebrates and honey bees but not with the other sequenced ecdysozoan genomes (honey bee-vertebrate specific, HVS genes) as a model. Results We identified 30 honey bee and 55 mouse HVS genes. Many HVS genes exhibited tissue-selective expression patterns; intriguingly, the expression of 60% of honey bee HVS genes was found to be brain enriched, and 24% of mouse HVS genes were highly expressed in either or both the brain and testis. Moreover, a minimum of 38% of mouse HVS genes demonstrated neuron-enriched expression patterns, and 62% of them exhibited expression in selective brain areas, particularly the forebrain and cerebellum. Furthermore, gene ontology (GO) analysis of HVS genes predicted that 35% of genes are associated with DNA transcription and RNA processing. Conclusion These results suggest that HVS genes include genes that are biased towards expression in the brain and gonads. They also demonstrate that at least some of Urbilaterian genes retained in the specific animal lineage may be selectively maintained to support the species-specific phenotypes. PMID:19138430
Expression profiles of urbilaterian genes uniquely shared between honey bee and vertebrates.
Matsui, Toshiaki; Yamamoto, Toshiyuki; Wyder, Stefan; Zdobnov, Evgeny M; Kadowaki, Tatsuhiko
2009-01-12
Large-scale comparison of metazoan genomes has revealed that a significant fraction of genes of the last common ancestor of Bilateria (Urbilateria) is lost in each animal lineage. This event could be one of the underlying mechanisms involved in generating metazoan diversity. However, the present functions of these ancient genes have not been addressed extensively. To understand the functions and evolutionary mechanisms of such ancient Urbilaterian genes, we carried out comprehensive expression profile analysis of genes shared between vertebrates and honey bees but not with the other sequenced ecdysozoan genomes (honey bee-vertebrate specific, HVS genes) as a model. We identified 30 honey bee and 55 mouse HVS genes. Many HVS genes exhibited tissue-selective expression patterns; intriguingly, the expression of 60% of honey bee HVS genes was found to be brain enriched, and 24% of mouse HVS genes were highly expressed in either or both the brain and testis. Moreover, a minimum of 38% of mouse HVS genes demonstrated neuron-enriched expression patterns, and 62% of them exhibited expression in selective brain areas, particularly the forebrain and cerebellum. Furthermore, gene ontology (GO) analysis of HVS genes predicted that 35% of genes are associated with DNA transcription and RNA processing. These results suggest that HVS genes include genes that are biased towards expression in the brain and gonads. They also demonstrate that at least some of Urbilaterian genes retained in the specific animal lineage may be selectively maintained to support the species-specific phenotypes.
Ceci n'est pas une micromachine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yarberry, Victor R.; Diegert, Carl F.
2010-03-01
The image created in reflected light DIC can often be interpreted as a true three-dimensional representation of the surface geometry, provided a clear distinction can be realized between raised and lowered regions in the specimen. It may be helpful if our definition of saliency embraces work on the human visual system (HVS) as well as the more abstract work on saliency, as it is certain that understanding by humans will always stand between recording of a useful signal from all manner of sensors and so-called actionable intelligence. A DARPA/DSO program lays down this requirement in a current program (Kruse 2010):more » The vision for the Neurotechnology for Intelligence Analysts (NIA) Program is to revolutionize the way that analysts handle intelligence imagery, increasing both the throughput of imagery to the analyst and overall accuracy of the assessments. Current computer-based target detection capabilities cannot process vast volumes of imagery with the speed, flexibility, and precision of the human visual system.« less
Prolonged post-hyperventilation apnea in two young adults with hyperventilation syndrome
2013-01-01
Background The prognosis of hyperventilation syndrome (HVS) is generally good. However, it is important to proceed with care when treating HVS because cases of death following hyperventilation have been reported. This paper was done to demonstrate the clinical risk of post-hyperventilation apnea (PHA) in patients with HVS. Case presentation We treated two patients with HVS who suffered from PHA. The first, a 21-year-old woman, had a maximum duration of PHA of about 3.5 minutes and an oxygen saturation (SpO2) level of 60%. The second patient, a 22-year-old woman, had a maximum duration of PHA of about 3 minutes and an SpO2 level of 66%. Both patients had loss of consciousness and cyanosis. Because there is no widely accepted regimen for treating patients with prolonged PHA related to HVS, we administered artificial ventilation to both patients using a bag mask and both recovered without any after effects. Conclusion These cases show that some patients with HVS develop prolonged PHA or severe hypoxia, which has been shown to lead to death in some cases. Proper treatment must be given to patients with HVS who develop PHA to protect against this possibility. If prolonged PHA or severe hypoxemia arises, respiratory assistance using a bag mask must be done immediately. PMID:23594702
Perceptual compression of magnitude-detected synthetic aperture radar imagery
NASA Technical Reports Server (NTRS)
Gorman, John D.; Werness, Susan A.
1994-01-01
A perceptually-based approach for compressing synthetic aperture radar (SAR) imagery is presented. Key components of the approach are a multiresolution wavelet transform, a bit allocation mask based on an empirical human visual system (HVS) model, and hybrid scalar/vector quantization. Specifically, wavelet shrinkage techniques are used to segregate wavelet transform coefficients into three components: local means, edges, and texture. Each of these three components is then quantized separately according to a perceptually-based bit allocation scheme. Wavelet coefficients associated with local means and edges are quantized using high-rate scalar quantization while texture information is quantized using low-rate vector quantization. The impact of the perceptually-based multiresolution compression algorithm on visual image quality, impulse response, and texture properties is assessed for fine-resolution magnitude-detected SAR imagery; excellent image quality is found at bit rates at or above 1 bpp along with graceful performance degradation at rates below 1 bpp.
Noble, H; Estcourt, C; Ison, C; Goold, P; Tite, L; Carter, Y H
2004-06-01
To describe the management of vaginal discharge in general practice, with particular regard to the use of the high vaginal swab (HVS), and to compare GPs' expectations of this test with the processing and reporting undertaken by different laboratories. A postal questionnaire survey of 2146 GPs in the North Thames area and postal questionnaire study of the 22 laboratories serving the same GPs were carried out. GPs were asked how they would manage a young woman with vaginal discharge and what information they would like on an HVS report. Laboratories were asked how they would process and report on the HVS sample from the same patient. Response rate was 26%. 72% of GPs would take an HVS and 62% would refer on to a genitourinary medicine (GUM) clinic. 45% would offer empirical therapy and 47% of these would treat for candida initially. 75% of GPs routinely request "M,C&S" on HVS samples but 55% only want to be informed about specific pathogens. Routine processing of HVS samples varies widely between laboratories and 86% only report specific pathogens. 78% of GPs would like to be offered a suggested diagnosis on HVS reports, and 74% would like a suggested treatment. 43% of laboratories ever provide a diagnosis, and 14% provide a suggested treatment. GPs frequently manage vaginal discharge and most of them utilise the HVS. GPs' expectations of the test are not well matched to laboratory processing or reporting of the samples.
NASA Astrophysics Data System (ADS)
Kristensen, Kasper; Bilde, Merete; Aalto, Pasi P.; Petäjä, Tuukka; Glasius, Marianne
2016-04-01
Carboxylic acids and organosulfates comprise an important fraction of atmospheric secondary organic aerosols formed from both anthropogenic and biogenic precursors. The partitioning of these compounds between the gas and particle phase is still unclear and further research is warranted to better understand the abundance and effect of organic acids and organosulfates on the formation and properties of atmospheric aerosols. This work compares atmospheric aerosols collected at an urban and a boreal forest site using two side-by-side sampling systems; a high volume sampler (HVS) and a low volume (LVS) denuder/filter sampling system allowing for separate collection of gas- and particle-phase organics. All particle filters and denuder samples were collected at H.C. Andersen Boulevard (HCAB), Copenhagen, Denmark in the summer of 2010, and at the remote boreal forest site at Hyytiälä forestry field station in Finland in the summer of 2012. The chemical composition of gas- and particle-phase secondary organic aerosol was investigated by ultra-high performance liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (UPLC/ESI-Q-TOFMS), with a focus on carboxylic acids and organosulfates. Results show gas-phase concentrations higher than those observed in the particle phase by a factor of 5-6 in HCAB 2010 and 50-80 in Hyytiälä 2012. Although abundant in the particle phase, no organosulfates were detected in the gas phase at either site. Through a comparison of samples collected by the HVS and the LVS denuder/filter sampling system we evaluate the potential artifacts associated with sampling of atmospheric aerosols. Such comparison shows that particle phase concentrations of semi-volatile organic acids obtained from the filters collected by HVS are more than two times higher than concentrations obtained from filters collected using LVS denuder/filter system. In most cases, higher concentrations of organosulfates are observed in particles collected by HVS compared to samples collected by LVS denuder/filter sampling system. The present study shows that volatile organics may absorb onto filter materials in the HVS (and similar sampling systems without denuder) and furthermore undergo subsequent on-filter oxidation and sulfation resulting in formation of both organic acids and organosulfates.
NASA Astrophysics Data System (ADS)
Dostal, P.; Krasula, L.; Klima, M.
2012-06-01
Various image processing techniques in multimedia technology are optimized using visual attention feature of the human visual system. Spatial non-uniformity causes that different locations in an image are of different importance in terms of perception of the image. In other words, the perceived image quality depends mainly on the quality of important locations known as regions of interest. The performance of such techniques is measured by subjective evaluation or objective image quality criteria. Many state-of-the-art objective metrics are based on HVS properties; SSIM, MS-SSIM based on image structural information, VIF based on the information that human brain can ideally gain from the reference image or FSIM utilizing the low-level features to assign the different importance to each location in the image. But still none of these objective metrics utilize the analysis of regions of interest. We solve the question if these objective metrics can be used for effective evaluation of images reconstructed by processing techniques based on ROI analysis utilizing high-level features. In this paper authors show that the state-of-the-art objective metrics do not correlate well with subjective evaluation while the demosaicing based on ROI analysis is used for reconstruction. The ROI were computed from "ground truth" visual attention data. The algorithm combining two known demosaicing techniques on the basis of ROI location is proposed to reconstruct the ROI in fine quality while the rest of image is reconstructed with low quality. The color image reconstructed by this ROI approach was compared with selected demosaicing techniques by objective criteria and subjective testing. The qualitative comparison of the objective and subjective results indicates that the state-of-the-art objective metrics are still not suitable for evaluation image processing techniques based on ROI analysis and new criteria is demanded.
Nations, Kari R; Bursi, Roberta; Dogterom, Peter; Ereshefsky, Larry; Gertsik, Lev; Mant, Tim; Schipper, Jacques
2012-09-01
A key challenge to dose selection in early central nervous system (CNS) clinical drug development is that patient tolerability profiles often differ from those of healthy volunteers (HVs), yet HVs are the modal population for determining doses to be investigated in phase II trials. Without clear tolerability data from the target patient population, first efficacy trials may include doses that are either too high or too low, creating undue risk for study participants and the development program overall. Bridging trials address this challenge by carefully investigating safety and tolerability in the target population prior to full-scale proof-of-concept trials. Org 26576 is an alpha-amino-3-hydroxy-5-methylisoxazole-4-propionic acid (AMPA) receptor positive allosteric modulator that acts by modulating ionotropic AMPA-type glutamate receptors to enhance glutamatergic neurotransmission. In preparation for phase II efficacy trials in major depressive disorder (MDD), two separate phase I trials were conducted to evaluate safety, tolerability, and pharmacokinetics in HVs and in the target patient population. Both trials were randomized and placebo controlled, and included multiple rising-dose cohorts (HV range 100-400 mg bid; MDD range 100-600 mg bid). HVs (n = 36) and patients with MDD (n = 54) were dosed under similarly controlled conditions in an inpatient facility, HVs for up to 14 days and MDD patients for up to 28 days. Safety, tolerability, and pharmacokinetics were assessed frequently. Despite comparable pharmacokinetic profiles, the maximum tolerated dose (MTD) in depressed patients was 450 mg bid, twice the MTD established in HVs. No clinically relevant safety issues associated with Org 26576 were noted. This article presents safety, tolerability, and pharmacokinetic data from two different populations examined under similar dosing conditions. The important implications of such bridging work in phase II dose selection are discussed, as are study design and data interpretation challenges.
Ipsiroglu, Osman S.; Hung, Yi-Hsuan Amy; Chan, Forson; Ross, Michelle L.; Veer, Dorothee; Soo, Sonja; Ho, Gloria; Berger, Mai; McAllister, Graham; Garn, Heinrich; Kloesch, Gerhard; Barbosa, Adriano Vilela; Stockler, Sylvia; McKellin, William; Vatikiotis-Bateson, Eric
2015-01-01
Introduction: Advanced video technology is available for sleep-laboratories. However, low-cost equipment for screening in the home setting has not been identified and tested, nor has a methodology for analysis of video recordings been suggested. Methods: We investigated different combinations of hardware/software for home-videosomnography (HVS) and established a process for qualitative and quantitative analysis of HVS-recordings. A case vignette (HVS analysis for a 5.5-year-old girl with major insomnia and several co-morbidities) demonstrates how methodological considerations were addressed and how HVS added value to clinical assessment. Results: We suggest an “ideal set of hardware/software” that is reliable, affordable (∼$500) and portable (=2.8 kg) to conduct non-invasive HVS, which allows time-lapse analyses. The equipment consists of a net-book, a camera with infrared optics, and a video capture device. (1) We present an HVS-analysis protocol consisting of three steps of analysis at varying replay speeds: (a) basic overview and classification at 16× normal speed; (b) second viewing and detailed descriptions at 4–8× normal speed, and (c) viewing, listening, and in-depth descriptions at real-time speed. (2) We also present a custom software program that facilitates video analysis and note-taking (Annotator©), and Optical Flow software that automatically quantifies movement for internal quality control of the HVS-recording. The case vignette demonstrates how the HVS-recordings revealed the dimension of insomnia caused by restless legs syndrome, and illustrated the cascade of symptoms, challenging behaviors, and resulting medications. Conclusion: The strategy of using HVS, although requiring validation and reliability testing, opens the floor for a new “observational sleep medicine,” which has been useful in describing discomfort-related behavioral movement patterns in patients with communication difficulties presenting with challenging/disruptive sleep/wake behaviors. PMID:25852578
Kraft, Michael S.; Henning, Golo; Fickenscher, Helmut; Lengenfelder, Doris; Tschopp, Jürg; Fleckenstein, Bernhard; Meinl, Edgar
1998-01-01
Herpesvirus saimiri (HVS) transforms human T cells to stable growth in vitro. Since HVS codes for two different antiapoptotic proteins, growth transformation by HVS might be expected to confer resistance to apoptosis. We found that the expression of both viral antiapoptotic genes was restricted to cultures with viral replication and absent in growth-transformed human T cells. A comparative examination of HVS-transformed T-cell clones and their native parental clones revealed that the expression of Bcl-2, Bcl-XL, Bax, and members of the tumor necrosis factor receptor (TNF-R) superfamily with a death domain, namely, TNF-RI, CD95, and TRAMP, were not modulated by HVS. Expression of CD30 was induced in HVS-transformed T cells, and these cells also expressed the CD30 ligand. Uninfected and transformed T cells were sensitive to CD95 ligation but resistant to apoptosis mediated by TRAIL or soluble TNF-α. CD95 ligand was constitutively expressed on transformed but not uninfected parental T cells. Both cell types showed similar sensitivity to cell death induction or inhibition of T-cell activation mediated by irradiation, oxygen radicals, dexamethasone, cyclosporine, and prostaglandin E2. Altogether, this study strongly suggests that growth transformation by HVS is based not on resistance to apoptosis but, rather, on utilization of normal cellular activation pathways. PMID:9525639
Mitochondrial control-region sequence variation in aboriginal Australians.
van Holst Pellekaan, S; Frommer, M; Sved, J; Boettcher, B
1998-01-01
The mitochondrial D-loop hypervariable segment 1 (mt HVS1) between nucleotides 15997 and 16377 has been examined in aboriginal Australian people from the Darling River region of New South Wales (riverine) and from Yuendumu in central Australia (desert). Forty-seven unique HVS1 types were identified, varying at 49 nucleotide positions. Pairwise analysis by calculation of BEPPI (between population proportion index) reveals statistically significant structure in the populations, although some identical HVS1 types are seen in the two contrasting regions. mt HVS1 types may reflect more-ancient distributions than do linguistic diversity and other culturally distinguishing attributes. Comparison with sequences from five published global studies reveals that these Australians demonstrate greatest divergence from some Africans, least from Papua New Guinea highlanders, and only slightly more from some Pacific groups (Indonesian, Asian, Samoan, and coastal Papua New Guinea), although the HVS1 types vary at different nucleotide sites. Construction of a median network, displaying three main groups, suggests that several hypervariable nucleotide sites within the HVS1 are likely to have undergone mutation independently, making phylogenetic comparison with global samples by conventional methods difficult. Specific nucleotide-site variants are major separators in median networks constructed from Australian HVS1 types alone and for one global selection. The distribution of these, requiring extended study, suggests that they may be signatures of different groups of prehistoric colonizers into Australia, for which the time of colonization remains elusive. PMID:9463317
Investigating hyperventilation syndrome in patients suffering from empty nose syndrome.
Mangin, David; Bequignon, Emilie; Zerah-Lancner, Francoise; Isabey, Daniel; Louis, Bruno; Adnot, Serge; Papon, Jean-François; Coste, André; Boyer, Laurent; Devars du Mayne, Marie
2017-09-01
Patients with empty nose syndrome (ENS) following turbinate surgery often complain about breathing difficulties. We set out to determine if dyspnea in patients with ENS was associated with hyperventilation syndrome (HVS). We hypothesized that lower airway symptoms in ENS could be explained by HVS. Observational prospective study. All consecutive patients referred to our center for ENS over 1 year were invited to participate. Patients completed the Nijmegen score and underwent a hyperventilation provocation test (HVPT) and arterial blood gas and cardiopulmonary tests. HVS was defined by a delayed return of the end-tidal partial pressure of carbon dioxide in the expired gas to baseline during HVPT. Patients with HVS were asked to complete the Sinonasal Outcome Test (SNOT)-16 questionnaire before and after a specific eight-session respiratory rehabilitation program. Twenty-two of the 29 patients referred for ENS during the study period were eligible for inclusion and underwent a complete workup. HVS was diagnosed in 17 of these patients (77.3%). In the five patients who completed the SNOT-16, the score was significantly lower after rehabilitation. This study suggests that HVS is frequent in patients with ENS, and that symptoms can be improved by respiratory rehabilitation. Pathophysiological links between ENS and HVS deserve to be further explored. 2b Laryngoscope, 127:1983-1988, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Ge, Shunnan; Yang, Chen; Li, Min; Li, Jiang; Chang, Xiaozan; Fu, Jian; Chen, Lei; Chang, Chongwang; Wang, Xuelian; Zhu, Junling; Gao, Guodong
2012-07-17
Studies on patients with Parkinson's disease and in animal models have observed enhanced synchronization of oscillations in several frequency bands within and between the cortical-basal ganglia (BG) structures. Recent research has also shown that synchronization of high-voltage spindles (HVSs) in the cortex, striatum and substantia nigra pars reticulate is increased by dopamine depletion. However, more evidence is needed to determine whether HVS activity in the whole cortex-BG network represents homologous alteration following dopamine depletion. As the globus pallidus (GP) is in a central position to propagate and synchronize oscillations in the cortical-BG circuits, we employed local-field potentials and electrocorticogram to simultaneously record oscillations in the GP and primary (M1) and secondary (M2) motor cortices on freely moving 6-hydroxydopamine (6-OHDA) lesioned and control rats. Results showed that HVS episodes recorded from GP, and M2 and M1 cortex areas were more numerous and longer in 6-OHDA lesioned rats compared to controls. Relative power associated with HVS activity in the GP, and M2 and M1 cortices of 6-OHDA lesioned rats was significantly greater than that for control rats. Coherence values for HVS activity between the GP, and M2 and M1 cortex areas were significantly increased by dopamine depletion. Time lag between the M1 cortex HVS and GP HVS was significantly shorter for dopamine depleted than normal rats. Findings indicate a crucial rule for dopamine in the regulation of HVS activity in the whole cortical-BG circuit, and suggest a close relationship between abnormally synchronized HVS oscillations in the cortex-BG network and Parkinson's disease. Copyright © 2012 Elsevier B.V. All rights reserved.
Pain uncertainty in patients with fibromyalgia, yoga practitioners, and healthy volunteers.
Bradshaw, David H; Donaldson, Gary W; Okifuji, Akiko
2012-01-01
Uncertainty about potentially painful events affects how pain is experienced. Individuals with fibromyalgia (FM) often exhibit anxiety and catastrophic thoughts regarding pain and difficulties dealing with pain uncertainty. The effects of pain uncertainty in predictably high odds (HO), predictably low odds (LO), and even odds (EO) conditions on subjective ratings of pain (PR) and skin conductance responses (SCR) following the administration of a painful stimulus were examined for individuals with fibromyalgia (IWFM), healthy volunteers (HVs), and yoga practitioners (YPs). We hypothesized IWFM would demonstrate the greatest physiological reactivity to pain uncertainty, followed by HVs and YPs, respectively. Nine IWFM, 7 YPs, and 10 HVs participated. Custom contrast estimates comparing responses for HO, LO, and EO pain conditions showed higher SCR for IWFM (CE = 1.27, p = 0.01) but not for HVs or for YPs. PR for the EO condition were significantly greater than for HO and LO conditions for IWFM (CE = 0.60, p = 0.012) but not for HVs or YPs. YPs had lower SCR and PR than did HVs. Results show that uncertainty regarding pain increases the experience of pain, whereas certainty regarding pain may reduce pain ratings for individuals with fibromyalgia.
Transition of planar Couette flow at infinite Reynolds numbers.
Itano, Tomoaki; Akinaga, Takeshi; Generalis, Sotos C; Sugihara-Seki, Masako
2013-11-01
An outline of the state space of planar Couette flow at high Reynolds numbers (Re<10^{5}) is investigated via a variety of efficient numerical techniques. It is verified from nonlinear analysis that the lower branch of the hairpin vortex state (HVS) asymptotically approaches the primary (laminar) state with increasing Re. It is also predicted that the lower branch of the HVS at high Re belongs to the stability boundary that initiates a transition to turbulence, and that one of the unstable manifolds of the lower branch of HVS lies on the boundary. These facts suggest HVS may provide a criterion to estimate a minimum perturbation arising transition to turbulent states at the infinite Re limit.
Perceptually tuned low-bit-rate video codec for ATM networks
NASA Astrophysics Data System (ADS)
Chou, Chun-Hsien
1996-02-01
In order to maintain high visual quality in transmitting low bit-rate video signals over asynchronous transfer mode (ATM) networks, a layered coding scheme that incorporates the human visual system (HVS), motion compensation (MC), and conditional replenishment (CR) is presented in this paper. An empirical perceptual model is proposed to estimate the spatio- temporal just-noticeable distortion (STJND) profile for each frame, by which perceptually important (PI) prediction-error signals can be located. Because of the limited channel capacity of the base layer, only coded data of motion vectors, the PI signals within a small strip of the prediction-error image and, if there are remaining bits, the PI signals outside the strip are transmitted by the cells of the base-layer channel. The rest of the coded data are transmitted by the second-layer cells which may be lost due to channel error or network congestion. Simulation results show that visual quality of the reconstructed CIF sequence is acceptable when the capacity of the base-layer channel is allocated with 2 multiplied by 64 kbps and the cells of the second layer are all lost.
Assessment of Pneumatic Controller Emission Measurements ...
Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co
Derfuss, Tobias; Fickenscher, Helmut; Kraft, Michael S.; Henning, Golo; Lengenfelder, Doris; Fleckenstein, Bernhard; Meinl, Edgar
1998-01-01
Viruses have evolved different strategies to interfere with host cell apoptosis. Herpesvirus saimiri (HVS) and other lymphotropic herpesviruses code for proteins that are homologous to the cellular antiapoptotic Bcl-2. In this study HVS-Bcl-2 was stably expressed in the human leukemia cell line Jurkat and in the murine T-cell hybridoma DO to assess its antiapoptotic spectrum and to gain further insight into its mode of action. HVS- Bcl-2 prevented apoptosis that occurs as a result of a disturbance of intracellular homeostasis by, for example, DNA damage or menadione, which gives rise to oxygen radicals. In Jurkat cells, HVS-Bcl-2 also inhibited apoptosis mediated by the death receptor CD95. In DO cells, HVS-Bcl-2 did not interfere with CD95-mediated apoptosis but blocked dexamethasone-induced cell death. Mitochondrial damage is a central coordinating event in apoptosis induced by different stimuli. To assess the integrity of mitochondria, we used rhodamine 123, which is released upon disturbance of the mitochondrial membrane potential, and determined the release of cytochrome c into the cytosol. Both signs of mitochondrial damage were prevented by HVS-Bcl-2. This viral protein also inhibited the generation of caspase-3-like DEVDase activity and blocked the cleavage of poly(ADP-ribose) polymerase, a natural substrate of caspase-3-like proteases. In conclusion, HVS-Bcl-2 protects against a great variety of apoptotic stimuli, stabilizes mitochondria, and acts upstream of the generation of caspase-3-like activity. PMID:9621051
The oleocanthal-based homovanillyl sinapate as a novel c-Met inhibitor
Mohyeldin, Mohamed M.; Akl, Mohamed R.; Ebrahim, Hassan Y.; Dragoi, Ana Maria; Dykes, Samantha; Cardelli, James A.; El Sayed, Khalid A.
2016-01-01
The hepatocyte growth factor (HGF)/mesenchymal-epithelial transition factor (c-Met) signaling axis has gained considerable attention as an attractive molecular target for therapeutic blockade of cancer. Inspired by the chemical structure of S (−)-oleocanthal, a natural secoiridoid from extra-virgin olive oil with documented anticancer activity against c-Met-dependent malignancies, the research presented herein reports on the discovery of the novel olive-derived homovanillyl sinapate (HVS) as a promising c-Met inhibitor. HVS was distinguished for its remarkable potency against wild-type c-Met and its oncogenic variant in cell-free assays and confirmed by in silico docking studies. Furthermore, HVS substantially impaired the c-Met-mediated growth across a broad spectrum of breast cancer cells, while similar treatment doses had no effect on the non-tumorigenic mammary epithelial cell growth. In addition, HVS caused a dose-dependent inhibition of HGF-induced, but not epidermal growth factor (EGF)-induced, cell scattering in addition to HGF-mediated migration, invasion, and 3-dimensional (3D) proliferation of tumor cell spheroids. HVS treatment effects were mediated via inhibition of ligand-mediated c-Met activation and its downstream mitogenic signaling and blocking molecular mediators involved in cellular motility across different cellular contexts. An interesting feature of HVS is its good selectivity for c-Met and Abelson murine leukemia viral oncogene homolog 1 (ABL1) when profiled against a panel of kinases. Docking studies revealed interactions likely to impart high dual affinity for both ABL1 and c-Met kinases. HVS markedly reduced tumor growth, showed excellent pharmacodynamics, and suppressed cell proliferation and microvessel density in an orthotopic model of triple negative breast cancer. Collectively, the present findings suggested that the oleocanthal-based HVS is a promising c-Met inhibitor lead entity with excellent therapeutic potential to control malignancies with aberrant c-Met activity. PMID:27086914
Ashford, Miriam T; Ayers, Susan; Olander, Ellinor K
2017-05-01
Anxiety is common among postpartum women and can have adverse effects on mother's and child's somatic and psychological health if left untreated. In the UK, nurses or midwifes with a specialisation in community public health nursing, also called health visitors (HVs), work with families who have children younger than 5 years of age and are therefore in a key position to identify and support women with postpartum mental health issues. Until recently, postpartum mental health support provided by HVs mainly focused on identifying and managing depression, but the updated clinical guidance by the National Institute for Health and Care Excellence also includes guidance regarding screening and psychological interventions for perinatal anxiety. This study therefore aimed to explore HVs' experiences of supporting women with postpartum anxiety and their views on currently available care. Using a qualitative approach, in-depth semi-structured interviews were conducted with 13 HVs from the UK between May and October 2015. Participants were interviewed in person at their workplace or on the phone/Skype. Using thematic analysis, four main themes emerged: identification and screening issues; importance of training; service usage; and status of current service provision. Women with postpartum anxiety were commonly encountered by HVs in their clinical practice and described as often heavily using their or other related healthcare services, which puts additional strain on HVs' already heavy workload. Issues with identifying and screening for postpartum anxiety were raised and the current lack of perinatal mental health training for HVs was highlighted. In addition, HVs described a current lack of good perinatal mental health services in general and specifically for anxiety. The study highlights the need for HV perinatal mental health training in general and postpartum anxiety specifically, as well as better coverage of specialist mental health services and the need for development of interventions targeted at postpartum anxiety. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Hayat, Khizar; Puech, William; Gesquière, Gilles
2010-04-01
We propose an adaptively synchronous scalable spread spectrum (A4S) data-hiding strategy to integrate disparate data, needed for a typical 3-D visualization, into a single JPEG2000 format file. JPEG2000 encoding provides a standard format on one hand and the needed multiresolution for scalability on the other. The method has the potential of being imperceptible and robust at the same time. While the spread spectrum (SS) methods are known for the high robustness they offer, our data-hiding strategy is removable at the same time, which ensures highest possible visualization quality. The SS embedding of the discrete wavelet transform (DWT)-domain depth map is carried out in transform domain YCrCb components from the JPEG2000 coding stream just after the DWT stage. To maintain synchronization, the embedding is carried out while taking into account the correspondence of subbands. Since security is not the immediate concern, we are at liberty with the strength of embedding. This permits us to increase the robustness and bring the reversibility of our method. To estimate the maximum tolerable error in the depth map according to a given viewpoint, a human visual system (HVS)-based psychovisual analysis is also presented.
Nonlinear mapping of the luminance in dual-layer high dynamic range displays
NASA Astrophysics Data System (ADS)
Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi
2009-02-01
It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.
Applications of just-noticeable depth difference model in joint multiview video plus depth coding
NASA Astrophysics Data System (ADS)
Liu, Chao; An, Ping; Zuo, Yifan; Zhang, Zhaoyang
2014-10-01
A new multiview just-noticeable-depth-difference(MJNDD) Model is presented and applied to compress the joint multiview video plus depth. Many video coding algorithms remove spatial and temporal redundancies and statistical redundancies but they are not capable of removing the perceptual redundancies. Since the final receptor of video is the human eyes, we can remove the perception redundancy to gain higher compression efficiency according to the properties of human visual system (HVS). Traditional just-noticeable-distortion (JND) model in pixel domain contains luminance contrast and spatial-temporal masking effects, which describes the perception redundancy quantitatively. Whereas HVS is very sensitive to depth information, a new multiview-just-noticeable-depth-difference(MJNDD) model is proposed by combining traditional JND model with just-noticeable-depth-difference (JNDD) model. The texture video is divided into background and foreground areas using depth information. Then different JND threshold values are assigned to these two parts. Later the MJNDD model is utilized to encode the texture video on JMVC. When encoding the depth video, JNDD model is applied to remove the block artifacts and protect the edges. Then we use VSRS3.5 (View Synthesis Reference Software) to generate the intermediate views. Experimental results show that our model can endure more noise and the compression efficiency is improved by 25.29 percent at average and by 54.06 percent at most compared to JMVC while maintaining the subject quality. Hence it can gain high compress ratio and low bit rate.
Self-organized Evaluation of Dynamic Hand Gestures for Sign Language Recognition
NASA Astrophysics Data System (ADS)
Buciu, Ioan; Pitas, Ioannis
Two main theories exist with respect to face encoding and representation in the human visual system (HVS). The first one refers to the dense (holistic) representation of the face, where faces have "holon"-like appearance. The second one claims that a more appropriate face representation is given by a sparse code, where only a small fraction of the neural cells corresponding to face encoding is activated. Theoretical and experimental evidence suggest that the HVS performs face analysis (encoding, storing, face recognition, facial expression recognition) in a structured and hierarchical way, where both representations have their own contribution and goal. According to neuropsychological experiments, it seems that encoding for face recognition, relies on holistic image representation, while a sparse image representation is used for facial expression analysis and classification. From the computer vision perspective, the techniques developed for automatic face and facial expression recognition fall into the same two representation types. Like in Neuroscience, the techniques which perform better for face recognition yield a holistic image representation, while those techniques suitable for facial expression recognition use a sparse or local image representation. The proposed mathematical models of image formation and encoding try to simulate the efficient storing, organization and coding of data in the human cortex. This is equivalent with embedding constraints in the model design regarding dimensionality reduction, redundant information minimization, mutual information minimization, non-negativity constraints, class information, etc. The presented techniques are applied as a feature extraction step followed by a classification method, which also heavily influences the recognition results.
Simulation of hybrid propulsion system using LSRG and single cylinder engine
NASA Astrophysics Data System (ADS)
Han, C.; Ohyama, K.; Wang, W. Q.
2017-11-01
Nowadays, more and more people are beginning to use hybrid vehicles (HVs). The drive system of HVs needs to produce the electric energy with the electric generator and gearbox powered by an engine. Therefore, the structure becomes complex and the cost is high. To solve this issue, this research proposes a new drive system design that combines the engine and a linear switched reluctance generator (LSRG). When the engine is operating, the LSRG can simultaneously assist the engine’s mechanical output or can generate power to charge the battery. In this research, three research steps are executed. In the first step, the LSRG is designed according to the size of normal engine. Then, finite element analysis is used to get the data of flux linkage and calculate the inductance and translator force. Finally, Simulink models of control system are constructed to verify the performance of LSRG.
Infrared and visible image fusion scheme based on NSCT and low-level visual features
NASA Astrophysics Data System (ADS)
Li, Huafeng; Qiu, Hongmei; Yu, Zhengtao; Zhang, Yafei
2016-05-01
Multi-scale transform (MST) is an efficient tool for image fusion. Recently, many fusion methods have been developed based on different MSTs, and they have shown potential application in many fields. In this paper, we propose an effective infrared and visible image fusion scheme in nonsubsampled contourlet transform (NSCT) domain, in which the NSCT is firstly employed to decompose each of the source images into a series of high frequency subbands and one low frequency subband. To improve the fusion performance we designed two new activity measures for fusion of the lowpass subbands and the highpass subbands. These measures are developed based on the fact that the human visual system (HVS) percept the image quality mainly according to its some low-level features. Then, the selection principles of different subbands are presented based on the corresponding activity measures. Finally, the merged subbands are constructed according to the selection principles, and the final fused image is produced by applying the inverse NSCT on these merged subbands. Experimental results demonstrate the effectiveness and superiority of the proposed method over the state-of-the-art fusion methods in terms of both visual effect and objective evaluation results.
Automatic video summarization driven by a spatio-temporal attention model
NASA Astrophysics Data System (ADS)
Barland, R.; Saadane, A.
2008-02-01
According to the literature, automatic video summarization techniques can be classified in two parts, following the output nature: "video skims", which are generated using portions of the original video and "key-frame sets", which correspond to the images, selected from the original video, having a significant semantic content. The difference between these two categories is reduced when we consider automatic procedures. Most of the published approaches are based on the image signal and use either pixel characterization or histogram techniques or image decomposition by blocks. However, few of them integrate properties of the Human Visual System (HVS). In this paper, we propose to extract keyframes for video summarization by studying the variations of salient information between two consecutive frames. For each frame, a saliency map is produced simulating the human visual attention by a bottom-up (signal-dependent) approach. This approach includes three parallel channels for processing three early visual features: intensity, color and temporal contrasts. For each channel, the variations of the salient information between two consecutive frames are computed. These outputs are then combined to produce the global saliency variation which determines the key-frames. Psychophysical experiments have been defined and conducted to analyze the relevance of the proposed key-frame extraction algorithm.
McCane, Lynn M; Heckman, Susan M; McFarland, Dennis J; Townsend, George; Mak, Joseph N; Sellers, Eric W; Zeitlin, Debra; Tenteromano, Laura M; Wolpaw, Jonathan R; Vaughan, Theresa M
2015-11-01
Brain-computer interfaces (BCIs) aimed at restoring communication to people with severe neuromuscular disabilities often use event-related potentials (ERPs) in scalp-recorded EEG activity. Up to the present, most research and development in this area has been done in the laboratory with young healthy control subjects. In order to facilitate the development of BCI most useful to people with disabilities, the present study set out to: (1) determine whether people with amyotrophic lateral sclerosis (ALS) and healthy, age-matched volunteers (HVs) differ in the speed and accuracy of their ERP-based BCI use; (2) compare the ERP characteristics of these two groups; and (3) identify ERP-related factors that might enable improvement in BCI performance for people with disabilities. Sixteen EEG channels were recorded while people with ALS or healthy age-matched volunteers (HVs) used a P300-based BCI. The subjects with ALS had little or no remaining useful motor control (mean ALS Functional Rating Scale-Revised 9.4 (±9.5SD) (range 0-25)). Each subject attended to a target item as the items in a 6×6 visual matrix flashed. The BCI used a stepwise linear discriminant function (SWLDA) to determine the item the user wished to select (i.e., the target item). Offline analyses assessed the latencies, amplitudes, and locations of ERPs to the target and non-target items for people with ALS and age-matched control subjects. BCI accuracy and communication rate did not differ significantly between ALS users and HVs. Although ERP morphology was similar for the two groups, their target ERPs differed significantly in the location and amplitude of the late positivity (P300), the amplitude of the early negativity (N200), and the latency of the late negativity (LN). The differences in target ERP components between people with ALS and age-matched HVs are consistent with the growing recognition that ALS may affect cortical function. The development of BCIs for use by this population may begin with studies in HVs but also needs to include studies in people with ALS. Their differences in ERP components may affect the selection of electrode montages, and might also affect the selection of presentation parameters (e.g., matrix design, stimulation rate). P300-based BCI performance in people severely disabled by ALS is similar to that of age-matched control subjects. At the same time, their ERP components differ to some degree from those of controls. Attention to these differences could contribute to the development of BCIs useful to those with ALS and possibly to others with severe neuromuscular disabilities. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Chenivesse, Cécile; Similowski, Thomas; Bautin, Nathalie; Fournier, Clément; Robin, Sophie; Wallaert, Benoît; Perez, Thierry
2014-03-01
Patients with hyperventilation syndrome (HVS) report severe symptom-related suffering and often complain from insufficient medical attention. However, quality of life data in this context are scarce. We aimed at assessing the health-related quality of life (HRQoL) of HVS patients. Twenty-one HVS patients with extensive cardiorespiratory workup including cardiopulmonary exercise testing (CPET) filled in the generic SF-36 questionnaire and the results were compared to French normal values. Correlations between SF36 dimensions and clinical and functional data were established. All SF-36 scores were markedly decreased in HVS patients compared to healthy subjects: Physical Functioning: 44 ± 24, Social Functioning: 57 ± 27, Role Physical: 21 ± 32, Role Emotional: 48 ± 42, Mental Health: 51 ± 27, Vitality: 34 ± 20, Body Pain: 41 ± 21, General Health: 42 ± 21. These figures were all significantly lower in the HVS patients respective to the normal reference population. They were also lower than corresponding values published in patients with asthma or chronic obstructive pulmonary disease (COPD). "Vitality" and "Physical Functioning" scores were correlated with Nijmegen score (r = -0.594, p = 0.047) and peak respiratory frequency during CPET (r = -0.644, p = 0.019). The SF-36 Social Functioning score was correlated with the ventilatory threshold (r = 0.629, p = 0.034), peak V'E/V'CO2 (ventilation/CO2 production) (r = 0.650, p = 0.016) and peak PaCO2 (r = -0.664, p = 0.027). In conclusion, this study shows that HRQoL can be severely impaired in patients with HVS, which is one more reason to take this condition seriously. Copyright © 2013 Elsevier Ltd. All rights reserved.
Computer-aided diagnosis based on enhancement of degraded fundus photographs.
Jin, Kai; Zhou, Mei; Wang, Shaoze; Lou, Lixia; Xu, Yufeng; Ye, Juan; Qian, Dahong
2018-05-01
Retinal imaging is an important and effective tool for detecting retinal diseases. However, degraded images caused by the aberrations of the eye can disguise lesions, so that a diseased eye can be mistakenly diagnosed as normal. In this work, we propose a new image enhancement method to improve the quality of degraded images. A new method is used to enhance degraded-quality fundus images. In this method, the image is converted from the input RGB colour space to LAB colour space and then each normalized component is enhanced using contrast-limited adaptive histogram equalization. Human visual system (HVS)-based fundus image quality assessment, combined with diagnosis by experts, is used to evaluate the enhancement. The study included 191 degraded-quality fundus photographs of 143 subjects with optic media opacity. Objective quality assessment of image enhancement (range: 0-1) indicated that our method improved colour retinal image quality from an average of 0.0773 (variance 0.0801) to an average of 0.3973 (variance 0.0756). Following enhancement, area under curves (AUC) were 0.996 for the glaucoma classifier, 0.989 for the diabetic retinopathy (DR) classifier, 0.975 for the age-related macular degeneration (AMD) classifier and 0.979 for the other retinal diseases classifier. The relatively simple method for enhancing degraded-quality fundus images achieves superior image enhancement, as demonstrated in a qualitative HVS-based image quality assessment. This retinal image enhancement may, therefore, be employed to assist ophthalmologists in more efficient screening of retinal diseases and the development of computer-aided diagnosis. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
ESIM: Edge Similarity for Screen Content Image Quality Assessment.
Ni, Zhangkai; Ma, Lin; Zeng, Huanqiang; Chen, Jing; Cai, Canhui; Ma, Kai-Kuang
2017-10-01
In this paper, an accurate full-reference image quality assessment (IQA) model developed for assessing screen content images (SCIs), called the edge similarity (ESIM), is proposed. It is inspired by the fact that the human visual system (HVS) is highly sensitive to edges that are often encountered in SCIs; therefore, essential edge features are extracted and exploited for conducting IQA for the SCIs. The key novelty of the proposed ESIM lies in the extraction and use of three salient edge features-i.e., edge contrast, edge width, and edge direction. The first two attributes are simultaneously generated from the input SCI based on a parametric edge model, while the last one is derived directly from the input SCI. The extraction of these three features will be performed for the reference SCI and the distorted SCI, individually. The degree of similarity measured for each above-mentioned edge attribute is then computed independently, followed by combining them together using our proposed edge-width pooling strategy to generate the final ESIM score. To conduct the performance evaluation of our proposed ESIM model, a new and the largest SCI database (denoted as SCID) is established in our work and made to the public for download. Our database contains 1800 distorted SCIs that are generated from 40 reference SCIs. For each SCI, nine distortion types are investigated, and five degradation levels are produced for each distortion type. Extensive simulation results have clearly shown that the proposed ESIM model is more consistent with the perception of the HVS on the evaluation of distorted SCIs than the multiple state-of-the-art IQA methods.
Rose, Jennie; Ablewhite, Joanne; Swift, Judy Anne; Nathan, Dilip; Atkinson, Pippa; Watson, Vicki; McMaster, Fiona
2017-01-01
Objective To assess the feasibility and acceptability of using digital technology for Proactive Assessment of Obesity Risk during Infancy (ProAsk) with the UK health visitors (HVs) and parents. Design Multicentre, pre- and post-intervention feasibility study with process evaluation. Setting Rural and urban deprived settings, UK community care. Participants 66 parents of infants and 22 HVs. Intervention ProAsk was delivered on a tablet device. It comprises a validated risk prediction tool to quantify overweight risk status and a therapeutic wheel detailing motivational strategies for preventive parental behaviour. Parents were encouraged to agree goals for behaviour change with HVs who received motivational interviewing training. Outcome measures We assessed recruitment, response and attrition rates. Demographic details were collected, and overweight risk status. The proposed primary outcome measure was weight-for-age z-score. The proposed secondary outcomes were parenting self-efficacy, maternal feeding style, infant diet and exposure to physical activity/sedentary behaviour. Qualitative interviews ascertained the acceptability of study processes and intervention fidelity. Results HVs screened 324/589 infants for inclusion in the study and 66/226 (29%) eligible infants were recruited. Assessment of overweight risk was completed on 53 infants and 40% of these were identified as above population risk. Weight-for-age z-score (SD) between the infants at population risk and those above population risk differed significantly at baseline (−0.67 SD vs 0.32 SD). HVs were able to collect data and calculate overweight risk for the infants. Protocol adherence and intervention fidelity was a challenge. HVs and parents found the information provided in the therapeutic wheel appropriate and acceptable. Conclusion Study recruitment and protocol adherence were problematic. ProAsk was acceptable to most parents and HVs, but intervention fidelity was low. There was limited evidence to support the feasibility of implementing ProAsk without significant additional resources. A future study could evaluate ProAsk as a HV-supported, parent-led intervention. Trial registration number NCT02314494 (Feasibility Study Results) PMID:28882926
Matsunami, Masatoshi; Fukuda, Akinari; Sasaki, Kengo; Uchida, Hajime; Shigeta, Takanobu; Hirata, Yoshihiro; Kanazawa, Hiroyuki; Horikawa, Reiko; Nakazawa, Atsuko; Suzuki, Tatsuya; Mizuta, Koichi; Kasahara, Mureo
2016-08-01
As the priority of LD-Domino LT is the safety of the first recipient, limitations and technical difficulties in the second recipient often occur. The most technically challenging part of LD-Domino LT is the reconstruction of the vessels. For the reconstruction of HVs, the native HVs were exteriorized as far as possible using a CUSA because longer extensive HVs are essential for facilitating the reconstruction. At the back table, the HVs of the domino graft were sutured together, and the single cuff of the HVs was anastomosed to the IVC by joining the orifices. The HAs, the presence of insufficient length, and multiple vessels in the whole liver rendered the reconstruction more difficult. We determined the dividing sites of the vessels according to the preoperative 3D-CT findings obtained in two institutions. This is the first case series using grafts in DLT obtained from LDLT for patients with MSUD between two institutions. In conclusion, LD-Domino LT is a safe and feasible therapeutic option to expand the donor pool by technical refinement in the reconstruction of the second recipient. Further studies with a greater accumulation of patients and a longer follow-up will be necessary to establish LD-Domino LT using an MSUD donor. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Efficient image enhancement using sparse source separation in the Retinex theory
NASA Astrophysics Data System (ADS)
Yoon, Jongsu; Choi, Jangwon; Choe, Yoonsik
2017-11-01
Color constancy is the feature of the human vision system (HVS) that ensures the relative constancy of the perceived color of objects under varying illumination conditions. The Retinex theory of machine vision systems is based on the HVS. Among Retinex algorithms, the physics-based algorithms are efficient; however, they generally do not satisfy the local characteristics of the original Retinex theory because they eliminate global illumination from their optimization. We apply the sparse source separation technique to the Retinex theory to present a physics-based algorithm that satisfies the locality characteristic of the original Retinex theory. Previous Retinex algorithms have limited use in image enhancement because the total variation Retinex results in an overly enhanced image and the sparse source separation Retinex cannot completely restore the original image. In contrast, our proposed method preserves the image edge and can very nearly replicate the original image without any special operation.
Can Direct Current Electrotherapy Be Used for Patients With Orthopedic Implants?
Thaler, Evangeline; Korte, Holger
2017-01-01
Introduction: Although electrotherapy appears to have particularly interesting applications in the field of postoperative orthopedic rehabilitation, relatively little scientifically based research has been conducted in the area of electrotherapy with regard to safety involving patients with orthopedic implants. Method: Three electrotherapy forms were tested, such as high-volt stimulation (HVS), transcutaneous electric nerve stimulation (TENS), and galvanic current (GAL), using a model system containing a metal implant plate to evaluate whether heating in excess of 3°C would occur. Results: All changes in temperature for HVS, GAL, and TENS therapeutic electrical currents observed in our model system fall below the predefined 3°C. Conclusion: To the best of our knowledge, this is the first experimental based observation that prolonged exposure to a direct electrical current at therapeutic strength does not result in heating of metal titanium plates. PMID:28255511
Tucker, E; Sweis, R; Anggiansah, A; Wong, T; Telakis, E; Knowles, K; Wright, J; Fox, M
2013-11-01
Measurement of esophago-gastric junction (EGJ) cross-sectional area (CSA) and distensibility by an Endolumenal Functional Lumen Imaging Probe (EndoFLIP®) may distinguish between gastro-esophageal reflux disease (GERD) patients and healthy volunteers (HV). We aimed to assess the agreement of EndoFLIP® measurements with clinical and physiologic diagnosis of GERD. Twenty-one HV and 18 patients with typical GERD symptoms were studied. After gastroscopy, EGJ CSA, and distensibility were measured by EndoFLIP®. Forty-eight hour esophageal pH monitoring was then performed by a wireless system. The ability of EndoFLIP® to discriminate GERD patient and HVs was assessed. Planned secondary analysis then assessed whether EGJ CSA and distensibility were increased in individuals with pathologic acid exposure. Healthy volunteers were younger and had lower body mass index (BMI; both p < 0.001). Pathologic acid exposure was present in 3/21 (14%) HVs and 9/18 (50%) patients (p = 0.126). At 30 mL EndoFLIP® bag volume, EGJ CSA was higher (p = 0.058) and EGJ distensibility was lower (p = 0.020) in HVs than patients. Secondary analysis showed that EGJ measurements were similar in participants with and without pathologic acid exposure (CSA 98 mm² vs 107 mm²; p = 0.789, distensibility; p = 0.704). An inverse association between BMI and CSA (R² = 0.2758, p = 0.001) and distensibility (R² = 0.2005, p = 0.005) was present. Endolumenal Functional Lumen Imaging Probe is not useful for GERD diagnosis because EGJ CSA and distensibility do not distinguish between HVs and GERD patients defined by clinical presentation or pH measurement. This unexpected result may be due to an important, confounding interaction of obesity. © 2013 John Wiley & Sons Ltd.
Kang, Yeona; Mozley, P David; Verma, Ajay; Schlyer, David; Henchcliffe, Claire; Gauthier, Susan A; Chiao, Ping C; He, Bin; Nikolopoulou, Anastasia; Logan, Jean; Sullivan, Jenna M; Pryor, Kane O; Hesterman, Jacob; Kothari, Paresh J; Vallabhajosula, Shankar
2018-05-04
Neuroinflammation has been implicated in the pathophysiology of Parkinson's disease (PD), which might be influenced by successful neuroprotective drugs. The uptake of [ 11 C](R)-PK11195 (PK) is often considered to be a proxy for neuroinflammation, and can be quantified using the Logan graphical method with an image-derived blood input function, or the Logan reference tissue model using automated reference region extraction. The purposes of this study were (1) to assess whether these noninvasive image analysis methods can discriminate between patients with PD and healthy volunteers (HVs), and (2) to establish the effect size that would be required to distinguish true drug-induced changes from system variance in longitudinal trials. The sample consisted of 20 participants with PD and 19 HVs. Two independent teams analyzed the data to compare the volume of distribution calculated using image-derived input functions (IDIFs), and binding potentials calculated using the Logan reference region model. With all methods, the higher signal-to-background in patients resulted in lower variability and better repeatability than in controls. We were able to use noninvasive techniques showing significantly increased uptake of PK in multiple brain regions of participants with PD compared to HVs. Although not necessarily reflecting absolute values, these noninvasive image analysis methods can discriminate between PD patients and HVs. We see a difference of 24% in the substantia nigra between PD and HV with a repeatability coefficient of 13%, showing that it will be possible to estimate responses in longitudinal, within subject trials of novel neuroprotective drugs. © 2018 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.
A fast and automatic fusion algorithm for unregistered multi-exposure image sequence
NASA Astrophysics Data System (ADS)
Liu, Yan; Yu, Feihong
2014-09-01
Human visual system (HVS) can visualize all the brightness levels of the scene through visual adaptation. However, the dynamic range of most commercial digital cameras and display devices are smaller than the dynamic range of human eye. This implies low dynamic range (LDR) images captured by normal digital camera may lose image details. We propose an efficient approach to high dynamic (HDR) image fusion that copes with image displacement and image blur degradation in a computationally efficient manner, which is suitable for implementation on mobile devices. The various image registration algorithms proposed in the previous literatures are unable to meet the efficiency and performance requirements in the application of mobile devices. In this paper, we selected Oriented Brief (ORB) detector to extract local image structures. The descriptor selected in multi-exposure image fusion algorithm has to be fast and robust to illumination variations and geometric deformations. ORB descriptor is the best candidate in our algorithm. Further, we perform an improved RANdom Sample Consensus (RANSAC) algorithm to reject incorrect matches. For the fusion of images, a new approach based on Stationary Wavelet Transform (SWT) is used. The experimental results demonstrate that the proposed algorithm generates high quality images at low computational cost. Comparisons with a number of other feature matching methods show that our method gets better performance.
An adaptive block-based fusion method with LUE-SSIM for multi-focus images
NASA Astrophysics Data System (ADS)
Zheng, Jianing; Guo, Yongcai; Huang, Yukun
2016-09-01
Because of the lenses' limited depth of field, digital cameras are incapable of acquiring an all-in-focus image of objects at varying distances in a scene. Multi-focus image fusion technique can effectively solve this problem. Aiming at the block-based multi-focus image fusion methods, the problem that blocking-artifacts often occurs. An Adaptive block-based fusion method based on lifting undistorted-edge structural similarity (LUE-SSIM) is put forward. In this method, image quality metrics LUE-SSIM is firstly proposed, which utilizes the characteristics of human visual system (HVS) and structural similarity (SSIM) to make the metrics consistent with the human visual perception. Particle swarm optimization(PSO) algorithm which selects LUE-SSIM as the object function is used for optimizing the block size to construct the fused image. Experimental results on LIVE image database shows that LUE-SSIM outperform SSIM on Gaussian defocus blur images quality assessment. Besides, multi-focus image fusion experiment is carried out to verify our proposed image fusion method in terms of visual and quantitative evaluation. The results show that the proposed method performs better than some other block-based methods, especially in reducing the blocking-artifact of the fused image. And our method can effectively preserve the undistorted-edge details in focus region of the source images.
A RONI Based Visible Watermarking Approach for Medical Image Authentication.
Thanki, Rohit; Borra, Surekha; Dwivedi, Vedvyas; Borisagar, Komal
2017-08-09
Nowadays medical data in terms of image files are often exchanged between different hospitals for use in telemedicine and diagnosis. Visible watermarking being extensively used for Intellectual Property identification of such medical images, leads to serious issues if failed to identify proper regions for watermark insertion. In this paper, the Region of Non-Interest (RONI) based visible watermarking for medical image authentication is proposed. In this technique, to RONI of the cover medical image is first identified using Human Visual System (HVS) model. Later, watermark logo is visibly inserted into RONI of the cover medical image to get watermarked medical image. Finally, the watermarked medical image is compared with the original medical image for measurement of imperceptibility and authenticity of proposed scheme. The experimental results showed that this proposed scheme reduces the computational complexity and improves the PSNR when compared to many existing schemes.
The association of visual memory with hippocampal volume.
Zammit, Andrea R; Ezzati, Ali; Katz, Mindy J; Zimmerman, Molly E; Lipton, Michael L; Sliwinski, Martin J; Lipton, Richard B
2017-01-01
In this study we investigated the role of hippocampal volume (HV) in visual memory. Participants were a subsample of older adults (> = 70 years) from the Einstein Aging Study. Visual performance was measured using the Complex Figure (CF) copy and delayed recall tasks from the Repeatable Battery for the Assessment of Neuropsychological Status. Linear regressions were fitted to study associations between HV and visual tasks. Participants' (n = 113, mean age = 78.9 years) average scores on the CF copy and delayed recall were 17.4 and 11.6, respectively. CF delayed recall was associated with total (β = .031, p = 0.001) and left (β = 0.031, p = 0.001) and right HVs (β = 0.24, p = 0.012). CF delayed recall remained significantly associated with left HV even after we also included right HV (β = 0.27, p = 0.025) and the CF copy task (β = 0.30, p = 0.009) in the model. CF copy did not show any significant associations with HV. Our results suggest that left HV contributes in retrieval of visual memory in older adults.
Hyperventilation in asthma: a validation study of the Nijmegen Questionnaire--NQ.
Grammatopoulou, Eirini P; Skordilis, Emmanouil K; Georgoudis, Georgios; Haniotou, Aikaterini; Evangelodimou, Afroditi; Fildissis, George; Katsoulas, Theodoros; Kalagiakos, Panagiotis
2014-10-01
The Nijmegen questionnaire (NQ) has previously been used for screening the hyperventilation syndrome (HVS) in asthmatics. However, no validity study has been reported so far. To examine the validity and reliability of the NQ in asthma patients and identify the prevalence of HVS. The NQ (n = 162) was examined for translation, construct, cross-sectional and discriminant validity as well as for internal consistency and test-retest reliability. Principal component analysis and exploratory factor analysis revealed a single factor solution with 11 items and 58.6% of explained variability. These 11 NQ items showed high internal consistency (Cronbach's alpha = 0.92) and test-retest reliability (IR = 0.98). Higher NQ scores were found in the following subgroups: women versus men (p < 0.01); participants with moderate versus mild asthma (p < 0.001) or uncontrolled versus controlled asthma (p < 0.001), and participants with breath-hold time (BHT) < 30 versus ≥ 30 s (p < 0.01) or end-tidal CO2 (ETCO2) ≤ 35 versus >35 mmHg (p < 0.001). A cut-off score of >17 discriminated the participants with regard to the presence of HVS. The NQ showed 92.73% sensitivity and 91.59% specificity. The total NQ score was found significantly correlated with ETCO2 (r = -0.68), RR (r = 0.66) and BHT (r = -0.65). The prevalence of HVS was found 34%. The NQ is a valid and reliable questionnaire for screening HVS in patients with stable mild-to-moderate asthma.
Kielmann, Karina; Datye, Vinita; Pradhan, Anagha; Rangan, Sheela
2014-01-01
While concepts such as ‘partnership’ are central to the terminology of private–public mix (PPM), little attention has been paid to how social relations are negotiated among the diverse actors responsible for implementing these inter-sectoral arrangements. India's Revised National Tuberculosis Control Programme (RNTCP) has used intermediary agents to facilitate the involvement of private providers in the expansion of Directly Observed Therapy, Short-Course (DOTS). We examine the roles of tuberculosis health visitors (TB HVs) in mediating working relationships among private providers, programme staff and patients that underpin a PPM-DOTS launched by the RNTCP in western Maharashtra. In addition to observations and informal interactions with the programme and participating health providers, researchers conducted in-depth interviews with senior programme officers and eight TB HVs. Framed by a political discourse of clinical governance, working relationships within the PPM are structured by the pluralistic context, social and professional hierarchies and paternalism of health care in India. TB HVs are at the nexus of these relationships, yet remain undervalued partly because accountability is measured through technical rather than social outcomes of the ‘partnership’. Close attention to the dynamics of power relations in working practices within the health system can improve accountability and sustainability of partnerships. PMID:25147003
Moyanova, Slavianka G; Kirov, Roumen K; Kortenska, Lidia V
2002-04-01
Age-related changes in neocortical high-voltage spindle (HVS) and in electroencephalographic (EEG) alpha power were examined in young (3.0 to 4.6 months), middle-aged (10.2 to 13.8 months), and old (21.5 to 24.0 months) male Wistar rats during quiet waking. Whereas the duration of quiet waking stage did not change as a function of age, a significant increase in HVS amount and EEG alpha peak power was observed in the middle-aged rats with only a tendency for a further enhancement in the old animals. An additional analysis showed that the elevation of alpha power is associated with age rather than with HVS activity.
Grayscale standard display function on LCD color monitors
NASA Astrophysics Data System (ADS)
De Monte, Denis; Casale, Carlo; Albani, Luigi; Bonfiglio, Silvio
2007-03-01
Currently, as a rule, digital medical systems use monochromatic Liquid Crystal Display (LCD) monitors to ensure an accurate reproduction of the Grayscale Standard Display Function (GSDF) as specified in the Digital Imaging and Communications in Medicine (DICOM) Standard. As a drawback, special panels need to be utilized in digital medical systems, while it would be preferable to use regular color panels, which are manufactured on a wide scale and are thus available at by far lower prices. The method proposed introduces a temporal color dithering technique to accurately reproduce the GSDF on color monitors without losing monitor resolution. By exploiting the characteristics of the Human Visual System (HVS) the technique ensures that a satisfactory grayscale reproduction is achieved minimizing perceivable flickering and undesired color artifacts. The algorithm has been implemented in the monitor using a low-cost Field Programmable Gate Array (FPGA). Quantitative evaluations of luminance response on a 3 Mega-pixel color monitor have shown that the compliance with the GSDF can be achieved with the accuracy level required by medical applications. At the same time the measured color deviation is below the threshold perceivable by the human eye.
Area and power efficient DCT architecture for image compression
NASA Astrophysics Data System (ADS)
Dhandapani, Vaithiyanathan; Ramachandran, Seshasayanan
2014-12-01
The discrete cosine transform (DCT) is one of the major components in image and video compression systems. The final output of these systems is interpreted by the human visual system (HVS), which is not perfect. The limited perception of human visualization allows the algorithm to be numerically approximate rather than exact. In this paper, we propose a new matrix for discrete cosine transform. The proposed 8 × 8 transformation matrix contains only zeros and ones which requires only adders, thus avoiding the need for multiplication and shift operations. The new class of transform requires only 12 additions, which highly reduces the computational complexity and achieves a performance in image compression that is comparable to that of the existing approximated DCT. Another important aspect of the proposed transform is that it provides an efficient area and power optimization while implementing in hardware. To ensure the versatility of the proposal and to further evaluate the performance and correctness of the structure in terms of speed, area, and power consumption, the model is implemented on Xilinx Virtex 7 field programmable gate array (FPGA) device and synthesized with Cadence® RTL Compiler® using UMC 90 nm standard cell library. The analysis obtained from the implementation indicates that the proposed structure is superior to the existing approximation techniques with a 30% reduction in power and 12% reduction in area.
The relationship between competition and quality in procedural cardiac care.
Glick, David B; Wroblewski, Kristen; Apfelbaum, Sean; Dauber, Benjamin; Woo, Joyce; Tung, Avery
2015-01-01
Anesthesiologists are frequently involved in efforts to meet perioperative quality metrics. The degree to which hospitals compete on publicly reported quality measures, however, is unclear. We hypothesized that hospitals in more competitive environments would be more likely to compete on quality and thus perform better on such measures. To test our hypothesis, we studied the relationship between competition and quality in hospitals providing procedural cardiac care and participating in a national quality database. For hospitals performing heart valve surgery (HVS) and delivering acute myocardial infarction (AMI) care in the Hospital Compare database, we assessed the degree of intrahospital competition using both geographical radius and federally defined metropolitan statistical area (MSA) to determine the degree of intrahospital competition. For each hospital, we then correlated the degree of competition with quality measure performance, mortality, patient volume, and per-patient Medicare costs for both HVS and AMI. Six hundred fifty-three hospitals met inclusion criteria for HVS and 1898 hospitals for AMI care. We found that for both definitions of competition, hospitals facing greater competition did not demonstrate better quality measure performance for either HVS or AMI. For both diagnoses, competition by number of hospitals correlated positively with cost: partial correlation coefficients = 0.40 (0.42 for MSA) (P < 0.001) for HVS and 0.52 (0.47 for MSA) (P < 0.001) for AMI. An analysis of the Hospital Compare database found that competition among hospitals correlated overall with increased Medicare costs but did not predict better scores on publicly reported quality metrics. Our results suggest that hospitals do not compete meaningfully on publicly reported quality metrics or costs.
A rare variant of the mtDNA HVS1 sequence in the hairs of Napoléon's family.
Lucotte, Gérard
2010-10-04
This paper describes the finding of a rare variant in the sequence of the hypervariable segment (HVS1) of mitochondrial (mtDNA) extracted from two preserved hairs, authenticated as belonging to the French Emperor Napoléon I (Napoléon Bonaparte). This rare variant is a mutation that changes the base C to T at position 16,184 (16184C→T), and it constitutes the only mutation found in this HVS1 sequence. This mutation is rare, because it was not found in a reference database (P < 0.05). In a personal database (M. Pala) comprising 37,000 different sequences, the 16184C→T mutation was found in only three samples, thus in this database the mutation frequency was 0.00008%. This mutation 16184C→T was also the only variant found subsequently in the HVS1 sequences of mtDNAs extracted from Napoléon's mother (Letizia) and from his youngest sister (Caroline), confirming that this mutation is maternally inherited. This 16184C→T variant could be used for genetic verification to authenticate any doubtful material and determine whether it should indeed be attributed to Napoléon.
A rare variant of the mtDNA HVS1 sequence in the hairs of Napoléon's family
2010-01-01
This paper describes the finding of a rare variant in the sequence of the hypervariable segment (HVS1) of mitochondrial (mtDNA) extracted from two preserved hairs, authenticated as belonging to the French Emperor Napoléon I (Napoléon Bonaparte). This rare variant is a mutation that changes the base C to T at position 16,184 (16184C→T), and it constitutes the only mutation found in this HVS1 sequence. This mutation is rare, because it was not found in a reference database (P < 0.05). In a personal database (M. Pala) comprising 37,000 different sequences, the 16184C→T mutation was found in only three samples, thus in this database the mutation frequency was 0.00008%. This mutation 16184C→T was also the only variant found subsequently in the HVS1 sequences of mtDNAs extracted from Napoléon's mother (Letizia) and from his youngest sister (Caroline), confirming that this mutation is maternally inherited. This 16184C→T variant could be used for genetic verification to authenticate any doubtful material and determine whether it should indeed be attributed to Napoléon. PMID:21092341
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vadasz, C.; Fleischer, A.; Carpi, D.
1995-02-27
Neocortical high-voltage spike-and-wave discharges (HVS) in the rat are an animal model of petit mal epilepsy. Genetic analysis of total duration of HVS (s/12 hr) in reciprocal F1 and F2 hybrids of F344 and BN rats indicated that the phenotypic variability of HVS cannot be explained by simple, monogenic Mendelian model. Biometrical analysis suggested the presence of additive, dominance, and sex-linked-epistatic effects, buffering maternal influence, and heterosis. High correlation was observed between average duration (s/episode) and frequency of occurrence of spike-and-wave episodes (n/12 hr) in parental and segregating generations, indicating that common genes affect both duration and frequency of themore » spike-and-wave pattern. We propose that both genetic and developmental - environmental factors control an underlying quantitative variable, which, above a certain threshold level, precipitates HVS discharges. These findings, together with the recent availability of rat DNA markers for total genome mapping, pave the way to the identification of genes that control the susceptibility of the brain to spike-and-wave discharges. 67 refs., 3 figs., 5 tabs.« less
Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou
2013-01-01
Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application. PMID:24194677
Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou
2013-01-01
Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.
Rizk, Mina M; Rubin-Falcone, Harry; Keilp, John; Miller, Jeffrey M; Sublette, M Elizabeth; Burke, Ainsley; Oquendo, Maria A; Kamal, Ahmed M; Abdelhameed, Mohamed A; Mann, J John
2017-11-01
Major depressive disorder (MDD) is associated with impaired attention control and alterations in frontal-subcortical connectivity. We hypothesized that attention control as assessed by Stroop task interference depends on white matter integrity in fronto-cingulate regions and assessed this relationship using diffusion tensor imaging (DTI) in MDD and healthy volunteers (HV). DTI images and Stroop task were acquired in 29 unmedicated MDD patients and 16 HVs, aged 18-65 years. The relationship between Stroop interference and fractional anisotropy (FA) was examined using region-of-interest (ROI) and tract-based spatial statistics (TBSS) analyses. ROI analysis revealed that Stroop interference correlated positively with FA in left caudal anterior cingulate cortex (cACC) in HVs (r = 0.62, p = 0.01), but not in MDD (r = -0.05, p= 0.79) even after controlling for depression severity. The left cACC was among 4 ROIs in fronto-cingulate network where FA was lower in MDD relative to HVs (F (1,41) = 8.87, p = 0.005). Additionally, TBSS showed the same group interaction of differences and correlations, although only at a statistical trend level. The modest sample size limits the generalizability of the findings. Structural connectivity of white matter network of cACC correlated with magnitude of Stroop interference in HVs, but not MDD. The cACC-frontal network, sub-serving attention control, may be disrupted in MDD. Less cognitive control may include enhanced effects of salience in HVs, or less effective response inhibition in MDD. Further studies of salience and inhibition components of executive function may better elucidate the relationship between brain white matter changes and executive dysfunction in MDD. Copyright © 2017 Elsevier B.V. All rights reserved.
Colt, J S
1998-01-01
Epidemiologic studies of the association between residential pesticide use and cancer risk require an assessment of past pesticide exposures. Pesticide levels in carpet dust are believed to reflect long-term pesticide use. Recent epidemiologic studies have found collection of dust samples using the high-volume surface sampler (HVS3) to be expensive and cumbersome. We compared the levels of pesticides and other compounds in dust obtained from subjects' personal used vacuum cleaner bags to that collected by the HVS3 to see if this simpler method could replace the HVS3 in epidemiologic research. We visited the homes of 15 subjects, took the used bags from their vacuums, and collected carpet dust samples with the HVS3. The samples were analyzed for 42 target compounds: 26 pesticides, 10 polycyclic aromatic hydrocarbons (PAHs), and six polychlorinated biphenyl (PCB) congeners using GC/MS in selected ion monitoring mode. The two methods agreed in detecting the presence of the target compounds between 80% and 100% of the time. Neither sampling method was consistently more sensitive. The median target compound concentrations were similar, and a paired t-test showed no significant differences. For many compounds, the concentrations of compounds in the HVS3 samples were higher than those in the used bag samples at the upper end of the concentration ranges. However, the Spearman rank correlation coefficients were 0.85 or higher for most compounds, indicating that homes would be ranked similarly using both methods. Overall, there appears to be no clear difference in the quality of the pesticide, PAH, or PCB concentration data for the two dust collection methods. Images Figure 1 PMID:9799187
Cleansing technique using high-velocity steam-air micromist jet spray.
Fukuda, Koichi; Ishihara, Masayuki; Murakami, Kaoru; Nakamura, Shingo; Sato, Yoko; Kuwabara, Masahiro; Fujita, Masanori; Kiyosawa, Tomoharu; Yokoe, Hidetaka
2017-10-01
Application of a high-velocity steam-air micromist jet spray (HVS-AMJS; micromist average diameter: 2.4 μm) for cleansing the skin is proposed. Low-pressure steam is mixed with compressed air (pH 6.5) in a nozzle, and then sprayed at a pressure of ≦0.25 MPa and a velocity of ≧0.34 m/s on the skin or surface of material located approximately 5-10 cm from the nozzle. The temperature on the sprayed surface and water flow rate could be controlled between 42 °C and 46 °C and at approximately 50 mL/min, respectively. Compared with ultrasonic cleansing with tap water and rubbing with only tap water, the HVS-AMJS successfully removed fluorescent lotion covering pieces of wood and significantly reduced both the number of coliforms and the total viable counts on pieces of wood and gauze. Furthermore, the HVS-AMJS effectively removed oily ink from the skin of hairless rats, and temporarily elevated the skin temperature and blood flow, indicating massage effects. The striking characteristics of this cleansing technique using HVS-AMJS are not only its ability to remove microbes and residue without using any chemicals or detergents but also its massage effects.
Li, Jiapeng; Huang, Xiaojun; Wang, Qian; Jing, Shan; Jiang, Hao; Wei, Zhongna; Zang, Yannan; Liu, Yang; Zhao, Libo; Fang, Yi; Feng, Wanyu
2015-10-01
Histamine dihydrochloride (HDC) injection has been approved in Europe for the treatment of adults with acute myeloid leukemia, used in combination therapy with the T-cell-derived cytokine interleukin-2. Despite years of clinical applications of HDC in Europe, no data are available on its tolerability and pharmacokinetic properties in Chinese patients. The objective of this study was to determine the safety profile and pharmacokinetic properties of HDC in Chinese healthy volunteers (HVs). In this Phase I, single-center, open-label, randomized study, 20 Chinese HVs were randomized to receive a single dose of 0.5 or 1.0 mg HDC via a 10-minute subcutaneous injection. Whole-blood and urine samples were collected at designated time points after dosing. Plasma and urine concentrations of histamine and metabolite N-methyl histamine were measured using a validated HPLC-MS/MS method. Pharmacokinetic parameters were estimated through noncompartmental procedures based on concentration-time data. Adverse events and evaluation of clinical laboratory tests were used to assess the safety profile. The pharmacokinetic profile for a single-dose of 1.0 mg HDC in Chinese HVs was compared with that in Western HVs. No severe adverse events occurred in this study, and the severity of all adverse events was grade I according to the Common Terminology Criteria for Adverse Events, version 4.0. For the pharmacokinetic parameters of histamine at the 0.5-mg and 1.0-mg dose levels, t½ was 0.50 and 1.02 hours; Tmax was 0.15 and 0.14 hours; mean Cmax was 26.59 and 71.01 nmol/L; AUC0-t was 8.35 and 20.43 nmol/h/L; AUC0-∞ was 9.61 and 22.69 nmol/h/L; accumulated amount excreted in urine within 24 hours was 125.93 and 145.52 nmol; and maximum urine excretion rates were 21.85 and 38.94 nmol/h, respectively. For N-methyl histamine at the 0.5-mg and 1.0-mg dose levels, t½ was 0.58 and 0.66 hours; Tmax was 0.28 and 0.26 hours; mean Cmax was 17.01 and 23.54 nmol/L; AUC0-t was 7.72 and 17.08 nmol/h/L; AUC0-∞ was 9.01 and 19.62 nmol/h/L; accumulated amount excreted in urine within 24 hours was 331.7 and 583.21 nmol; and maximum urine excretion rates were 53.29 and 133.53 nmol/h, respectively. Both single-dose 0.5 mg and 1.0 mg HDC were well tolerated in Chinese HVs, and the pharmacokinetic profile of HDC in Chinese HVs was characterized in this study. A single dose of 1.0 mg HDC had a more rapid but similar extent of absorption, a wider distribution, and a little more rapid elimination in Chinese HVs compared with Western HVs. Findings from this study support additional clinical trials for HDC using in Chinese patients. Chinese Clinical Trial Registry identifier: ChiCTR-ONC-13003954. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.
McLeod, D. Scott; Hasegawa, Takuya; Baba, Takayuki; Grebe, Rhonda; Galtier d'Auriac, Ines; Merges, Carol; Edwards, Malia; Lutty, Gerard A.
2012-01-01
Purpose. The mode of development of the human hyaloid vascular system (HVS) remains unclear. Early studies suggested that these blood vessels formed by vasculogenesis, while the current concept seems to favor angiogenesis as the mode of development. We examined embryonic and fetal human HVS using a variety of techniques to gain new insights into formation of this vasculature. Methods. Embryonic and fetal human eyes from 5.5 to 12 weeks gestation (WG) were prepared for immunohistochemical analysis or for light and electron microscopy. Immunolabeling of sections with a panel of antibodies directed at growth factors, transcription factors, and hematopoietic stem cell markers was employed. Results. Light microscopic examination revealed free blood islands (BI) in the embryonic vitreous cavity (5.5–7 WG). Giemsa stain revealed that BI were aggregates of mesenchymal cells and primitive nucleated erythroblasts. Free cells were also observed. Immunolabeling demonstrated that BI were composed of mesenchymal cells that expressed hemangioblast markers (CD31, CD34, C-kit, CXCR4, Runx1, and VEGFR2), erythroblasts that expressed embryonic hemoglobin (Hb-ε), and cells that expressed both. Few cells were proliferating as determined by lack of Ki67 antigen. As development progressed (12 WG), blood vessels became more mature structurally with pericyte investment and basement membrane formation. Concomitantly, Hb-ε and CXCR4 expression was down-regulated and von Willebrand factor expression was increased with the formation of Weibel-Palade bodies. Conclusions. Our results support the view that the human HVS, like the choriocapillaris, develops by hemo-vasculogenesis, the process by which vasculogenesis, erythropoiesis, and hematopoiesis occur simultaneously from common precursors, hemangioblasts. PMID:23092923
Management of childhood gastroenteritis in the community.
Rahman, S; Aszkenasy, O M
2001-07-01
Good evidence-based research exists for the management of gastroenteritis. However, we encountered local anecdotal evidence of wide variations in the management of gastroenteritis. In order to assess the prevailing practice in gastroenteritis management in primary care, in the Tees Health region, an anonymous questionnaire study involving general practitioners (GPs) and health visitors (HVs) was performed. Three case scenarios were presented in the questionnaire, involving a breast-fed infant, a formula-fed infant and a four-y-old child all with diarrhoea and vomiting, but able to tolerate oral fluids and not ill enough to need hospital admission. Most GPs (78.6%) and HVs (80.5%) advised continuation of breast-feeding, though the practice of giving advice to stop breast-feeding, starve the child and substitute inappropriate fluids such as flat coke, was still common. For infants who were bottle-fed, this inappropriate advice was given much more commonly (only 25.6% and 52.8% of GPs and HVs, respectively gave advice to continue bottle-feeding). This was even more true for the four-y-old, for whom advice to continue with a normal diet was very much the exception (7.7% of GPs and 19.5% of HVs). Advice given to parents of children with gastroenteritis was inconsistent and, in many cases, inappropriate. This has implications for clinical governance. There is an urgent need for the development and implementation of local guidelines.
Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults.
Jones, Mandy; Harvey, Alex; Marston, Louise; O'Connell, Neil E
2013-05-31
Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tremor and paraesthesia. DB/HVS has an estimated prevalence of 9.5% in the general adult population, however, there is little consensus regarding the most effective management of this patient group. (1) To determine whether breathing exercises in patients with DB/HVS have beneficial effects as measured by quality of life indices (2) To determine whether there are any adverse effects of breathing exercises in patients with DB/HVS SEARCH METHODS: We identified trials for consideration using both electronic and manual search strategies. We searched CENTRAL, MEDLINE, EMBASE, and four other databases. The latest search was in February 2013. We planned to include randomised, quasi-randomised or cluster randomised controlled trials (RCTs) in which breathing exercises, or a combined intervention including breathing exercises as a key component, were compared with either no treatment or another therapy that did not include breathing exercises in patients with DB/HVS. Observational studies, case studies and studies utilising a cross-over design were not eligible for inclusion.We considered any type of breathing exercise for inclusion in this review, such as breathing control, diaphragmatic breathing, yoga breathing, Buteyko breathing, biofeedback-guided breathing modification, yawn/sigh suppression. Programs where exercises were either supervised or unsupervised were eligible as were relaxation techniques and acute-episode management, as long as it was clear that breathing exercises were a key component of the intervention.We excluded any intervention without breathing exercises or where breathing exercises were not key to the intervention. Two review authors independently checked search results for eligible studies, assessed all studies that appeared to meet the selection criteria and extracted data. We used standard procedures recommended by The Cochrane Collaboration. We included a single RCT assessed at unclear risk of bias, which compared relaxation therapy (n = 15) versus relaxation therapy and breathing exercises (n = 15) and a no therapy control group (n = 15).Quality of life was not an outcome measure in this RCT, and no numerical data or statistical analysis were presented in this paper. A significant reduction in the frequency and severity of hyperventilation attacks in the breathing exercise group compared with the control group was reported. In addition, a significant difference in frequency and severity of hyperventilation attacks between the breathing and relaxation group was reported. However, no information could be extracted from the paper regarding the size of the treatment effects. The results of this systematic review are unable to inform clinical practice, based on the inclusion of only one small, poorly reported RCT. There is no credible evidence regarding the effectiveness of breathing exercises for the clinical symptoms of DB/HVS. It is currently unknown whether these interventions offer any added value in this patient group or whether specific types of breathing exercise demonstrate superiority over others. Given that breathing exercises are frequently used to treat DB/HVS, there is an urgent need for further well designed clinical trials in this area. Future trials should conform to the CONSORT statement for standards of reporting and use appropriate, validated outcome measures. Trial reports should also ensure full disclosure of data for all important clinical outcomes.
Thomas, Laura A; Brotman, Melissa A; Muhrer, Eli J; Rosen, Brooke H; Bones, Brian L; Reynolds, Richard C; Deveney, Christen M; Pine, Daniel S; Leibenluft, Ellen
2012-12-01
CONTEXT Youth with bipolar disorder (BD) and those with severe, nonepisodic irritability (severe mood dysregulation [SMD]) exhibit amygdala dysfunction during facial emotion processing. However, studies have not compared such patients with each other and with comparison individuals in neural responsiveness to subtle changes in facial emotion; the ability to process such changes is important for social cognition. To evaluate this, we used a novel, parametrically designed faces paradigm. OBJECTIVE To compare activation in the amygdala and across the brain in BD patients, SMD patients, and healthy volunteers (HVs). DESIGN Case-control study. SETTING Government research institute. PARTICIPANTS Fifty-seven youths (19 BD, 15 SMD, and 23 HVs). MAIN OUTCOME MEASURE Blood oxygenation level-dependent data. Neutral faces were morphed with angry and happy faces in 25% intervals; static facial stimuli appeared for 3000 milliseconds. Participants performed hostility or nonemotional facial feature (ie, nose width) ratings. The slope of blood oxygenation level-dependent activity was calculated across neutral-to-angry and neutral-to-happy facial stimuli. RESULTS In HVs, but not BD or SMD participants, there was a positive association between left amygdala activity and anger on the face. In the neutral-to-happy whole-brain analysis, BD and SMD participants modulated parietal, temporal, and medial-frontal areas differently from each other and from that in HVs; with increasing facial happiness, SMD patients demonstrated increased, and BD patients decreased, activity in the parietal, temporal, and frontal regions. CONCLUSIONS Youth with BD or SMD differ from HVs in modulation of amygdala activity in response to small changes in facial anger displays. In contrast, individuals with BD or SMD show distinct perturbations in regions mediating attention and face processing in association with changes in the emotional intensity of facial happiness displays. These findings demonstrate similarities and differences in the neural correlates of facial emotion processing in BD and SMD, suggesting that these distinct clinical presentations may reflect differing dysfunctions along a mood disorders spectrum.
Just Noticeable Distortion Model and Its Application in Color Image Watermarking
NASA Astrophysics Data System (ADS)
Liu, Kuo-Cheng
In this paper, a perceptually adaptive watermarking scheme for color images is proposed in order to achieve robustness and transparency. A new just noticeable distortion (JND) estimator for color images is first designed in the wavelet domain. The key issue of the JND model is to effectively integrate visual masking effects. The estimator is an extension to the perceptual model that is used in image coding for grayscale images. Except for the visual masking effects given coefficient by coefficient by taking into account the luminance content and the texture of grayscale images, the crossed masking effect given by the interaction between luminance and chrominance components and the effect given by the variance within the local region of the target coefficient are investigated such that the visibility threshold for the human visual system (HVS) can be evaluated. In a locally adaptive fashion based on the wavelet decomposition, the estimator applies to all subbands of luminance and chrominance components of color images and is used to measure the visibility of wavelet quantization errors. The subband JND profiles are then incorporated into the proposed color image watermarking scheme. Performance in terms of robustness and transparency of the watermarking scheme is obtained by means of the proposed approach to embed the maximum strength watermark while maintaining the perceptually lossless quality of the watermarked color image. Simulation results show that the proposed scheme with inserting watermarks into luminance and chrominance components is more robust than the existing scheme while retaining the watermark transparency.
Hypervelocity star candidates in Gaia DR1/TGAS
NASA Astrophysics Data System (ADS)
Marchetti, T.; Rossi, E. M.; Kordopatis, G.; Brown, A. G. A.; Rimoldi, A.; Starkenburg, E.; Youakim, K.; Ashley, R.
2018-04-01
Hypervelocity stars (HVSs) are characterized by a total velocity in excess of the Galactic escape speed, and with trajectories consistent with coming from the Galactic Centre. We apply a novel data mining routine, an artificial neural network, to discover HVSs in the TGAS subset of the first data release of the Gaia satellite, using only the astrometry of the stars. We find 80 stars with a predicted probability >90% of being HVSs, and we retrieved radial velocities for 47 of those. We discover 14 objects with a total velocity in the Galactic rest frame >400 km s-1, and 5 of these have a probability >50% of being unbound from the Milky Way. Tracing back orbits in different Galactic potentials, we discover 1 HVS candidate, 5 bound HVS candidates, and 5 runaway star candidates with remarkably high velocities, between 400 and 780 km s-1. We wait for future Gaia releases to confirm the goodness of our sample and to increase the number of HVS candidates.
Proinflammatory cytokine levels in fibromyalgia patients are independent of body mass index.
Hernandez, Maria E; Becerril, Enrique; Perez, Mayra; Leff, Philippe; Anton, Benito; Estrada, Sergio; Estrada, Iris; Sarasa, Manuel; Serrano, Enrique; Pavon, Lenin
2010-06-03
Fibromyalgia (FM) is characterized by chronic, widespread muscular pain and tenderness and is generally associated with other somatic and psychological symptoms. Further, circulatory levels of proinflammatory cytokines (IL-1beta, TNF-alpha, and IL-6) may be altered in FM patients, possibly in association with their symptoms. Recently, rises in BMI have been suggested to contribute to increased circulating levels of proinflammatory cytokines in FM patients. Our aim was to measure the circulatory levels of proinflammatory cytokines to determine the influence of BMI on these levels in FM patients and healthy volunteers (HVs). In Spanish FM patients (n = 64) and HVs (n = 25), we measured BMI and serum concentrations of proinflammatory cytokines by capture ELISA. There were significant differences in BMI levels between FM patients (26.40 +/- 4.46) and HVs (23.64 +/- 3.45) and significant increase in IL-6 in FM patients (16.28 +/- 8.13 vs 0.92 +/- 0.32 pg/ml) (P < 0.001). IL-1beta and TNF-alpha decreased in FM patients compared with HVs. By ANCOVA, there was no significant association between BMI and TNF-alpha (F = 0.098, p = 0.75) or IL-6 (F = 0.221, p = 0.63) levels in FM patients. Our analysis in FM patients of BMI as a covariate of proinflammatory cytokines levels showed that serum TNF-alpha and IL-6 levels are independent of BMI. Further studies are necessary to dissect these findings and their implication in future therapeutic approaches for FM patients.
Chemale, Gustavo; Paneto, Greiciane Gaburro; Menezes, Meiga Aurea Mendes; de Freitas, Jorge Marcelo; Jacques, Guilherme Silveira; Cicarelli, Regina Maria Barretto; Fagundes, Paulo Roberto
2013-05-01
Mitochondrial DNA (mtDNA) analysis is usually a last resort in routine forensic DNA casework. However, it has become a powerful tool for the analysis of highly degraded samples or samples containing too little or no nuclear DNA, such as old bones and hair shafts. The gold standard methodology still constitutes the direct sequencing of polymerase chain reaction (PCR) products or cloned amplicons from the HVS-1 and HVS-2 (hypervariable segment) control region segments. Identifications using mtDNA are time consuming, expensive and can be very complex, depending on the amount and nature of the material being tested. The main goal of this work is to develop a less labour-intensive and less expensive screening method for mtDNA analysis, in order to aid in the exclusion of non-matching samples and as a presumptive test prior to final confirmatory DNA sequencing. We have selected 14 highly discriminatory single nucleotide polymorphisms (SNPs) based on simulations performed by Salas and Amigo (2010) to be typed using SNaPShot(TM) (Applied Biosystems, Foster City, CA, USA). The assay was validated by typing more than 100 HVS-1/HVS-2 sequenced samples. No differences were observed between the SNP typing and DNA sequencing when results were compared, with the exception of allelic dropouts observed in a few haplotypes. Haplotype diversity simulations were performed using 172 mtDNA sequences representative of the Brazilian population and a score of 0.9794 was obtained when the 14 SNPs were used, showing that the theoretical prediction approach for the selection of highly discriminatory SNPs suggested by Salas and Amigo (2010) was confirmed in the population studied. As the main goal of the work is to develop a screening assay to skip the sequencing of all samples in a particular case, a pair-wise comparison of the sequences was done using the selected SNPs. When both HVS-1/HVS-2 SNPs were used for simulations, at least two differences were observed in 93.2% of the comparisons performed. The assay was validated with casework samples. Results show that the method is straightforward and can be used for exclusionary purposes, saving time and laboratory resources. The assay confirms the theoretic prediction suggested by Salas and Amigo (2010). All forensic advantages, such as high sensitivity and power of discrimination, as also the disadvantages, such as the occurrence of allele dropouts, are discussed throughout the article. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Srivanitchapoom, Prachaya; Shamim, Ejaz A; Diomi, Pierre; Hattori, Takaaki; Pandey, Sanjay; Vorbach, Sherry; Park, Jung E; Wu, Tianxia; Auh, Sungyoung; Hallett, Mark
Exploratory case-control study. Writer's cramp (WC) is a type of focal hand dystonia. The central nervous system plays a role in its pathophysiology, but abnormalities in the affected musculoskeletal components may also be relevant. We compared the active range of motion (ROM) in patients with WC and healthy volunteers (HVs) and correlated the findings with disease duration and severity. Affected limb joints were measured with goniometers. Patients were assessed at least 3 months after their last botulinum toxin (botulinum neurotoxin) injection, and strength was clinically normal. t tests were used to compare the ROMs of WC with matched HVs. The Spearman correlation coefficient assessed the relationship of active ROMs to the disease duration and handwriting subscore of the Dystonia Disability Scale. ROMs of D1 metacarpophalangeal (MCP) joint extension as well as D2 and D5 MCP flexion were significantly smaller in WC, and distal interphalangeal joint extension in D3 and D5 was significantly greater compared with HVs. There were negative correlations between D2 MCP flexion and disease duration and with Dystonia Disability Scale. Abnormalities in ROMs in WC were found. Severity and disease duration correlated with reduced D2 MCP flexion. This may be related to intrinsic biomechanical abnormalities, co-contraction of muscles, or a combination of subclinical weakness and atrophy from repeated botulinum neurotoxin injections. Hand biomechanical properties should not be ignored in the pathophysiology of WC. 2c. Copyright © 2016 Hanley & Belfus. All rights reserved.
Peckover, Sue; Aston, Megan
2018-01-01
To critically examine surveillance practices of health visitors (HV) in the UK and public health nurses (PHNs) in Canada. The practice and meaning of surveillance shifts and changes depending on the context and intent of relationships between mothers and HVs or PHNs. We present the context and practice of HVs in the UK and PHNs in Canada and provide a comprehensive literature review regarding surveillance of mothers within public health systems. We then present our critique of the meaning and practice of surveillance across different settings. Concepts from Foucault and discourse analysis are used to critically examine and discuss the meaning of surveillance. Surveillance is a complex concept that shifts meaning and is socially and institutionally constructed through relations of power. Healthcare providers need to understand the different meanings and practices associated with surveillance to effectively inform practice. Healthcare providers should be aware of how their positions of expert and privilege within healthcare systems affect relationships with mothers. A more comprehensive understanding of personal, social and institutional aspects of surveillance will provide opportunities to reflect upon and change practices that are supportive of mothers and their families. © 2017 John Wiley & Sons Ltd.
Stereo chromatic contrast sensitivity model to blue-yellow gratings.
Yang, Jiachen; Lin, Yancong; Liu, Yun
2016-03-07
As a fundamental metric of human visual system (HVS), contrast sensitivity function (CSF) is typically measured by sinusoidal gratings at the detection of thresholds for psychophysically defined cardinal channels: luminance, red-green, and blue-yellow. Chromatic CSF, which is a quick and valid index to measure human visual performance and various retinal diseases in two-dimensional (2D) space, can not be directly applied into the measurement of human stereo visual performance. And no existing perception model considers the influence of chromatic CSF of inclined planes on depth perception in three-dimensional (3D) space. The main aim of this research is to extend traditional chromatic contrast sensitivity characteristics to 3D space and build a model applicable in 3D space, for example, strengthening stereo quality of 3D images. This research also attempts to build a vision model or method to check human visual characteristics of stereo blindness. In this paper, CRT screen was clockwise and anti-clockwise rotated respectively to form the inclined planes. Four inclined planes were selected to investigate human chromatic vision in 3D space and contrast threshold of each inclined plane was measured with 18 observers. Stimuli were isoluminant blue-yellow sinusoidal gratings. Horizontal spatial frequencies ranged from 0.05 to 5 c/d. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. According to the relationship between spatial frequency of inclined plane and horizontal spatial frequency, the chromatic contrast sensitivity characteristics in 3D space have been modeled based on the experimental data. The results show that the proposed model can well predicted human chromatic contrast sensitivity characteristics in 3D space.
Pires, João; Kuenzli, Esther; Kasraian, Sara; Tinguely, Regula; Furrer, Hansjakob; Hilty, Markus; Hatz, Christoph; Endimiani, Andrea
2016-01-01
We aimed to assess the intestinal colonization dynamics by multiple extended-spectrum cephalosporin-resistant Enterobacteriaceae (ESC-R-Ent) clones in Swiss travelers to India, a country with high prevalence of these multidrug-resistant pathogens. Fifteen healthy volunteers (HVs) colonized with ESC-R-Ent after traveling to India who provided stools before, after, and at 3- and 6-month follow-up are presented in this study. Stools were enriched in a LB broth containing 3 mg/L cefuroxime and plated in standard selective media (BLSE, ChromID ESBL, Supercarba) to detect carbapenem- and/or ESC-R-Ent. At least 5 Enterobacteriaceae colonies were analyzed for each stool provided. All strains underwent phenotypic tests (MICs in microdilution) and molecular typing to define bla genes (microarray, PCR/sequencing), clonality (MLST, rep-PCR), and plasmid content. While only three HVs were colonized before the trip, all participants had positive stools after returning, but the colonization rate decreased during the follow-up period (i.e., six HVs were still colonized at both 3 and 6 months). More importantly, polyclonal acquisition (median of 2 clones, range 1–5) was identified at return in all HVs. The majority of the Escherichia coli isolates belonged to phylogenetic groups A and B1 and to high diverse non-epidemic sequence types (STs); however, 15% of them belonged to clonal complex 10 and mainly possessed blaCTX−M−15 genes. F family plasmids were constantly found (~80%) in the recovered ESC-R-Ent. Our results indicate a possible polyclonal acquisition of the ESC-R-Ent via food-chain and/or through an environmental exposure. For some HVs, prolonged colonization in the follow-up period was observed due to clonal persistence or presence of the same plasmid replicon types in a new bacterial host. Travel medicine practitioners, clinicians, and clinical microbiologists who are facing the returning travelers and their samples for different reasons should be aware of this important phenomenon, so that better infection control measures, treatment strategies, and diagnostic tests can be adopted. PMID:27462305
Reddy, Palakolanu Sudhakar; Kavi Kishor, Polavarapu B.; Seiler, Christiane; Kuhlmann, Markus; Eschen-Lippold, Lennart; Lee, Justin; Reddy, Malireddy K.; Sreenivasulu, Nese
2014-01-01
The rapid increase in heat shock proteins upon exposure to damaging stresses and during plant development related to desiccation events reveal their dual importance in plant development and stress tolerance. Genome-wide sequence survey identified 20 non-redundant small heat shock proteins (sHsp) and 22 heat shock factor (Hsf) genes in barley. While all three major classes (A, B, C) of Hsfs are localized in nucleus, the 20 sHsp gene family members are localized in different cell organelles like cytoplasm, mitochondria, plastid and peroxisomes. Hsf and sHsp members are differentially regulated during drought and at different seed developmental stages suggesting the importance of chaperone role under drought as well as seed development. In silico cis-regulatory motif analysis of Hsf promoters showed an enrichment with abscisic acid responsive cis-elements (ABRE), implying regulatory role of ABA in mediating transcriptional response of HvsHsf genes. Gene regulatory network analysis identified HvHsfB2c as potential central regulator of the seed-specific expression of several HvsHsps including 17.5CI sHsp. These results indicate that HvHsfB2c is co-expressed in the central hub of small Hsps and therefore it may be regulating the expression of several HvsHsp subclasses HvHsp16.88-CI, HvHsp17.5-CI and HvHsp17.7-CI. The in vivo relevance of binding specificity of HvHsfB2C transcription factor to HSE-element present in the promoter of HvSHP17.5-CI under heat stress exposure is confirmed by gel shift and LUC-reporter assays. Further, we isolated 477 bp cDNA from barley encoding a 17.5 sHsp polypeptide, which was predominantly upregulated under drought stress treatments and also preferentially expressed in developing seeds. Recombinant HvsHsp17.5-CI protein was expressed in E. coli and purified to homogeneity, which displayed in vitro chaperone activity. The predicted structural model of HvsHsp-17.5-CI protein suggests that the α-crystallin domain is evolutionarily highly conserved. PMID:24594978
Reddy, Palakolanu Sudhakar; Kavi Kishor, Polavarapu B; Seiler, Christiane; Kuhlmann, Markus; Eschen-Lippold, Lennart; Lee, Justin; Reddy, Malireddy K; Sreenivasulu, Nese
2014-01-01
The rapid increase in heat shock proteins upon exposure to damaging stresses and during plant development related to desiccation events reveal their dual importance in plant development and stress tolerance. Genome-wide sequence survey identified 20 non-redundant small heat shock proteins (sHsp) and 22 heat shock factor (Hsf) genes in barley. While all three major classes (A, B, C) of Hsfs are localized in nucleus, the 20 sHsp gene family members are localized in different cell organelles like cytoplasm, mitochondria, plastid and peroxisomes. Hsf and sHsp members are differentially regulated during drought and at different seed developmental stages suggesting the importance of chaperone role under drought as well as seed development. In silico cis-regulatory motif analysis of Hsf promoters showed an enrichment with abscisic acid responsive cis-elements (ABRE), implying regulatory role of ABA in mediating transcriptional response of HvsHsf genes. Gene regulatory network analysis identified HvHsfB2c as potential central regulator of the seed-specific expression of several HvsHsps including 17.5CI sHsp. These results indicate that HvHsfB2c is co-expressed in the central hub of small Hsps and therefore it may be regulating the expression of several HvsHsp subclasses HvHsp16.88-CI, HvHsp17.5-CI and HvHsp17.7-CI. The in vivo relevance of binding specificity of HvHsfB2C transcription factor to HSE-element present in the promoter of HvSHP17.5-CI under heat stress exposure is confirmed by gel shift and LUC-reporter assays. Further, we isolated 477 bp cDNA from barley encoding a 17.5 sHsp polypeptide, which was predominantly upregulated under drought stress treatments and also preferentially expressed in developing seeds. Recombinant HvsHsp17.5-CI protein was expressed in E. coli and purified to homogeneity, which displayed in vitro chaperone activity. The predicted structural model of HvsHsp-17.5-CI protein suggests that the α-crystallin domain is evolutionarily highly conserved.
Savarino, Edoardo; Zentilin, Patrizia; Mastracci, Luca; Dulbecco, Pietro; Marabotto, Elisa; Gemignani, Lorenzo; Bruzzone, Luca; de Bortoli, Nicola; Frigo, Anna Chiara; Fiocca, Roberto; Savarino, Vincenzo
2013-04-01
Microscopic esophagitis (ME) is common in patients with non-erosive reflux disease (NERD), and dilation of intercellular spaces (DIS) has been regarded as the potential main mechanism of symptom generation. We aimed to compare these histological abnormalities in healthy volunteers (HVs) and patients with erosive esophagitis (EE), NERD, and functional heartburn (FH). Consecutive patients with heartburn prospectively underwent upper endoscopy and impedance-pH off-therapy. Twenty EE patients and fifty-seven endoscopy-negative patients (NERD), subclassified as 22 with pH-POS (positive for abnormal acid exposure), 20 with hypersensitive esophagus (HE; normal acid/symptom association probability [SAP]+ or symptom index [SI]+), and 15 with FH (normal acid/SAP-/SI-/ proton pump inhibitor [PPI] test-), were enrolled. Twenty HVs were also included. In each patient/control, multiple specimens (n = 5) were taken from the distal esophagus and histological alterations were evaluated. ME was diagnosed when the global histological score was >0.35. The prevalence of ME was higher (p < 0.0001) in EE (95 %), pH-POS (77 %), and HE (65 %) NERD patients than in FH patients (13 %) and HVs (15 %). Also, basal cell hyperplasia (p < 0.0023), DIS (p < 0.0001), and papillae elongation (p < 0.0002) showed similar rates of prevalence in the above populations (p < 0.0001). ME, including each histological lesion, had similar low frequencies in FH and HVs (p = 0.9990). Considering the histological abnormalities together, they permitted us to clearly differentiate EE and NERD from FH and HVs (p < 0.0001 and p < 0.0001, respectively). The lack of ME in the esophageal distal biopsies of FH patients indicates a limited role of these histological abnormalities in symptom generation in them. ME can be considered as an accurate and reliable diagnostic marker for distinguishing FH patients from GERD patients and has the potential to be used to guide the correct therapy.
NASA Astrophysics Data System (ADS)
Dong, Xiabin; Huang, Xinsheng; Zheng, Yongbin; Bai, Shengjian; Xu, Wanying
2014-07-01
Infrared moving target detection is an important part of infrared technology. We introduce a novel infrared small moving target detection method based on tracking interest points under complicated background. Firstly, Difference of Gaussians (DOG) filters are used to detect a group of interest points (including the moving targets). Secondly, a sort of small targets tracking method inspired by Human Visual System (HVS) is used to track these interest points for several frames, and then the correlations between interest points in the first frame and the last frame are obtained. Last, a new clustering method named as R-means is proposed to divide these interest points into two groups according to the correlations, one is target points and another is background points. In experimental results, the target-to-clutter ratio (TCR) and the receiver operating characteristics (ROC) curves are computed experimentally to compare the performances of the proposed method and other five sophisticated methods. From the results, the proposed method shows a better discrimination of targets and clutters and has a lower false alarm rate than the existing moving target detection methods.
Leveque, M; Seidermann, L; Tran, H; Langagne, T; Ulmer, E; Chays, A
2010-06-01
Vestibular neurectomy is considered the reference treatment of incapacitating vertigo accompanying Meniere disease, with an efficiency rate of 85-95% in most literature reports. The aim of this study is to evaluate if vestibular neurectomy can provide a complete vestibular deafferentation by investigating complete vestibular function after surgery. Prospective study. Twenty-four patients suffering from incapacitated Meniere vertigo crisis beneficiated from a vestibular neurectomy by retrosigmoid approach. The average time between surgery and vestibular evaluation was 1 year. We performed (i) kinetic test, (ii) caloric test and (iii) vibration-induced nystagmus (VIN) at 30, 60 and 100Hz under videonystagmography recording, (iv) vestibular evoked myogenic potentials (VEMP), (v) video head impulsed test (VHIT) for each semicircular canals and (vi) an evaluation of visual vertical and horizontal subjective (VVS and HVS). On clinical evaluation, all the patients except one had never experienced any recurrence of vertigo crisis after surgery. The 24 patients would definitely undergo the surgery again. On vestibular evaluation, on the operated side, all patients showed a total areflexia at caloric test; 23 patients had no VEMP response; 23 patients had abolished canals response to VHIT. All the patients had VVS and HVS deviated towards the operated side; 23 patients had a high velocity VIN from 30 to 60Hz. This study proves that vestibular neurectomy can provide a complete vestibular deafferentation. We discuss this vestibular evaluation protocol and the main difficulties encounter during surgery, which could lead to partial nerve section and partial relief, and explain residual vestibular function after vestibular neurectomy. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Vector quantizer based on brightness maps for image compression with the polynomial transform
NASA Astrophysics Data System (ADS)
Escalante-Ramirez, Boris; Moreno-Gutierrez, Mauricio; Silvan-Cardenas, Jose L.
2002-11-01
We present a vector quantization scheme acting on brightness fields based on distance/distortion criteria correspondent with psycho-visual aspects. These criteria quantify sensorial distortion between vectors that represent either portions of a digital image or alternatively, coefficients of a transform-based coding system. In the latter case, we use an image representation model, namely the Hermite transform, that is based on some of the main perceptual characteristics of the human vision system (HVS) and in their response to light stimulus. Energy coding in the brightness domain, determination of local structure, code-book training and local orientation analysis are all obtained by means of the Hermite transform. This paper, for thematic reasons, is divided in four sections. The first one will shortly highlight the importance of having newer and better compression algorithms. This section will also serve to explain briefly the most relevant characteristics of the HVS, advantages and disadvantages related with the behavior of our vision in front of ocular stimulus. The second section shall go through a quick review of vector quantization techniques, focusing their performance on image treatment, as a preview for the image vector quantizer compressor actually constructed in section 5. Third chapter was chosen to concentrate the most important data gathered on brightness models. The building of this so-called brightness maps (quantification of the human perception on the visible objects reflectance), in a bi-dimensional model, will be addressed here. The Hermite transform, a special case of polynomial transforms, and its usefulness, will be treated, in an applicable discrete form, in the fourth chapter. As we have learned from previous works 1, Hermite transform has showed to be a useful and practical solution to efficiently code the energy within an image block, deciding which kind of quantization is to be used upon them (whether scalar or vector). It will also be a unique tool to structurally classify the image block within a given lattice. This particular operation intends to be one of the main contributions of this work. The fifth section will fuse the proposals derived from the study of the three main topics- addressed in the last sections- in order to propose an image compression model that takes advantage of vector quantizers inside the brightness transformed domain to determine the most important structures, finding the energy distribution inside the Hermite domain. Sixth and last section will show some results obtained while testing the coding-decoding model. The guidelines to evaluate the image compressing performance were the compression ratio, SNR and psycho-visual quality. Some conclusions derived from the research and possible unexplored paths will be shown on this section as well.
Effect of dehydration on the development of collaterals in acute middle cerebral artery occlusion.
Chang, S-W; Huang, Y-C; Lin, L-C; Yang, J-T; Weng, H-H; Tsai, Y-H; Lee, T-H
2016-03-01
Recent large series studies have demonstrated that dehydration is common amongst stroke subjects and is associated with poor outcome. However, the effects of hydration status on the development of collaterals have never been discussed. In this study, the hypothesis that hydration status is an important factor for developing collaterals after acute middle cerebral artery (MCA) infarction was tested. Eighty-seven patients with acute infarction due to occlusion of the MCA were enrolled. Two collateral markers, posterior cerebral artery (PCA) laterality and fluid-attenuated inversion recovery hyperintense vessels (HVs) were assessed from magnetic resonance imaging. Dehydration status was defined by a nitrogen to creatinine ratio ≧ of 15. The associations between dehydration status and the development of collaterals were estimated. Sixty-one of 87 patients (70.1%) were identified as dehydrated. The development of PCA laterality and HVs shows a significant difference between dehydrated and euhydrated patients. A serum nitrogen to creatinine ratio <15, diastolic blood pressure and the presence of a dense MCA on computed tomography were significantly associated with the development of PCA laterality. A serum nitrogen to creatinine ratio <15, the initial National Institutes of Health Stroke Scale score, the presence of a dense MCA and calcifications of the internal carotid artery on computed tomography were significantly associated with the development of HVs. Dehydration remained an independent negative predictor for the development of PCA laterality and HVs in the multivariate analysis. Hydration status is associated with the development of collateral flow after acute MCA occlusion. This preliminary study provides an imaging clue that hydration status and early hydration therapy could be important for acute stroke management. © 2016 EAN.
Ranaweera, Lanka; Kaewsutthi, Supannee; Win Tun, Aung; Boonyarit, Hathaichanoke; Poolsuwan, Samerchai; Lertrit, Patcharee
2014-01-01
Located only a short distance off the southernmost shore of the Greater Indian subcontinent, the island of Sri Lanka has long been inhabited by various ethnic populations. Mainly comprising the Vedda, Sinhalese (Up- and Low-country) and Tamil (Sri Lankan and Indian); their history of settlements on the island and the biological relationships among them have remained obscure. It has been hypothesized that the Vedda was probably the earliest inhabitants of the area, followed by Sinhalese and Tamil from the Indian mainland. This study, in which 271 individuals, representing the Sri Lankan ethnic populations mentioned, were typed for their mitochondrial DNA (mtDNA) hypervariable segment 1 (HVS-1) and part of hypervariable segment 2 (HVS-2), provides implications for their settlement history on the island. From the phylogenetic, principal coordinate and analysis of molecular variance results, the Vedda occupied a position separated from all other ethnic people of the island, who formed relatively close affiliations among themselves, suggesting a separate origin of the former. The haplotypes and analysis of molecular variance revealed that Vedda people's mitochondrial sequences are more related to the Sinhalese and Sri Lankan Tamils' than the Indian Tamils' sequences. MtDNA haplogroup analysis revealed that several West Eurasian haplogroups as well as Indian-specific mtDNA clades were found amongst the Sri Lankan populations. Through a comparison with the mtDNA HVS-1 and part of HVS-2 of Indian database, both Tamils and Sinhalese clusters were affiliated with Indian subcontinent populations than Vedda people who are believed to be the native population of the island of Sri Lanka.
Hartmannella vermiformis inhibition of Legionella pneumophila cultivability.
Buse, Helen Y; Donohue, Maura J; Ashbolt, Nicholas J
2013-10-01
Hartmannella vermiformis and Acanthamoeba polyphaga are frequently isolated from drinking water and permissive to Legionella pneumophila parasitization. In this study, extracellular factor(s) produced by H. vermiformis and A. polyphaga were assessed for their effects on cultivability of L. pneumophila. Page's amoeba saline (PAS) was used as an encystment medium for H. vermiformis and A. polyphaga monolayers, and the culture supernatants (HvS and ApS, respectively) were assessed against L. pneumophila growth. Compared to PAS and ApS, HvS significantly inhibited L. pneumophila strain Philadelphia-1 (Ph-1) cultivability by 3 log(10) colony forming unit (CFU) mL(-1) after 3 days of exposure compared to <0.5 log(10) CFU mL(-1) reduction of strain Lp02 (P < 0.001). Flow cytometric analysis revealed changes in the percentage and cultivability of three bacterial subpopulations: intact/slightly damaged membrane (ISM), undefined membrane status (UD), and mixed type (MT). After 3 days of HvS exposure, the MT subpopulation decreased significantly (31.6 vs 67.2 %, respectively, P < 0.001), while the ISM and UD subpopulations increased (+26.7 and +6.9 %, respectively) with the ISM subpopulation appearing as viable but nonculturable (VBNC) cells. HvS was separated into two fractions based on molecular weight, with more than 99 % of the L. pneumophila inhibition arising from the <5 kDa fraction (P < 0.001). Liquid chromatography indicated the inhibitory molecule(s) are likely polar and elute from a Novapak C18 column between 6 and 15 min. These results demonstrate that H. vermiformis is capable of extracellular modulation of L. pneumophila cultivability and probably promote the VBNC state for this bacterium.
Gupta, Vinay K; Arora, Monika; Sharma, Indrani; Nazar, Gaurang P; Modi, Bhavesh; Singh, Deepti; Millett, Christopher; Reddy, K Srinath
2013-01-01
India's Smoke-Free Law (SFL) was implemented in 2004 and reinforced on 2nd October 2008. This research attempts to understand the knowledge and opinion of hospitality venue (HV) managers about second-hand smoke (SHS) and SFL as well as self-reported compliance with SFL in two Indian states. A survey was conducted among 804 randomly sampled HVs from project STEPS (Strengthening of tobacco control efforts through innovative partnerships and strategies) in Gujarat and Andhra Pradesh, India. Four hundred and three HVs from two districts in Gujarat and 401 HVs from six districts in Andhra Pradesh were selected. The owner, manager or supervisor of each HV was interviewed using a pre-tested structured interview schedule. Association of opinion scales with respondents' background characteristics was assessed through the analysis of variance (ANOVA) method. Out of the 403 respondents in Gujarat and 401 in Andhra Pradesh, 56.1% and 84.3% had knowledge about SFL respectively. Compliance of HVs with SFL was 21.8% in Gujarat and 31.2% in Andhra Pradesh as reported by the managers. Knowledge about SHS was noted among 39.7% of respondents in Gujarat and 25.4% in Andhra Pradesh. Bivariate results indicated that more educated HV managers showed higher support for smoke-free public places (P < 0.001) and were more concerned about the health effects of SHS exposure (P = 0.002). Complete self-reported compliance with, and knowledge of SFL as well as SHS was not found in Gujarat and Andhra Pradesh. The education level of HV managers is an important determinant to ensure compliance with SFL in public places.
Neonatal Hypoxia, Hippocampal Atrophy, and Memory Impairment: Evidence of a Causal Sequence
Cooper, Janine M.; Gadian, David G.; Jentschke, Sebastian; Goldman, Allan; Munoz, Monica; Pitts, Georgia; Banks, Tina; Chong, W. Kling; Hoskote, Aparna; Deanfield, John; Baldeweg, Torsten; de Haan, Michelle; Mishkin, Mortimer; Vargha-Khadem, Faraneh
2015-01-01
Neonates treated for acute respiratory failure experience episodes of hypoxia. The hippocampus, a structure essential for memory, is particularly vulnerable to such insults. Hence, some neonates undergoing treatment for acute respiratory failure might sustain bilateral hippocampal pathology early in life and memory problems later in childhood. We investigated this possibility in a cohort of 40 children who had been treated neonatally for acute respiratory failure but were free of overt neurological impairment. The cohort had mean hippocampal volumes (HVs) significantly below normal control values, memory scores significantly below the standard population means, and memory quotients significantly below those predicted by their full scale IQs. Brain white matter volume also fell below the volume of the controls, but brain gray matter volumes and scores on nonmnemonic neuropsychological tests were within the normal range. Stepwise linear regression models revealed that the cohort's HVs were predictive of degree of memory impairment, and gestational age at treatment was predictive of HVs: the younger the age, the greater the atrophy. We conclude that many neonates treated for acute respiratory failure sustain significant hippocampal atrophy as a result of the associated hypoxia and, consequently, show deficient memory later in life. PMID:24343890
Neonatal hypoxia, hippocampal atrophy, and memory impairment: evidence of a causal sequence.
Cooper, Janine M; Gadian, David G; Jentschke, Sebastian; Goldman, Allan; Munoz, Monica; Pitts, Georgia; Banks, Tina; Chong, W Kling; Hoskote, Aparna; Deanfield, John; Baldeweg, Torsten; de Haan, Michelle; Mishkin, Mortimer; Vargha-Khadem, Faraneh
2015-06-01
Neonates treated for acute respiratory failure experience episodes of hypoxia. The hippocampus, a structure essential for memory, is particularly vulnerable to such insults. Hence, some neonates undergoing treatment for acute respiratory failure might sustain bilateral hippocampal pathology early in life and memory problems later in childhood. We investigated this possibility in a cohort of 40 children who had been treated neonatally for acute respiratory failure but were free of overt neurological impairment. The cohort had mean hippocampal volumes (HVs) significantly below normal control values, memory scores significantly below the standard population means, and memory quotients significantly below those predicted by their full scale IQs. Brain white matter volume also fell below the volume of the controls, but brain gray matter volumes and scores on nonmnemonic neuropsychological tests were within the normal range. Stepwise linear regression models revealed that the cohort's HVs were predictive of degree of memory impairment, and gestational age at treatment was predictive of HVs: the younger the age, the greater the atrophy. We conclude that many neonates treated for acute respiratory failure sustain significant hippocampal atrophy as a result of the associated hypoxia and, consequently, show deficient memory later in life. © The Author 2013. Published by Oxford University Press.
Sequence-length variation of mtDNA HVS-I C-stretch in Chinese ethnic groups.
Chen, Feng; Dang, Yong-hui; Yan, Chun-xia; Liu, Yan-ling; Deng, Ya-jun; Fulton, David J R; Chen, Teng
2009-10-01
The purpose of this study was to investigate mitochondrial DNA (mtDNA) hypervariable segment-I (HVS-I) C-stretch variations and explore the significance of these variations in forensic and population genetics studies. The C-stretch sequence variation was studied in 919 unrelated individuals from 8 Chinese ethnic groups using both direct and clone sequencing approaches. Thirty eight C-stretch haplotypes were identified, and some novel and population specific haplotypes were also detected. The C-stretch genetic diversity (GD) values were relatively high, and probability (P) values were low. Additionally, C-stretch length heteroplasmy was observed in approximately 9% of individuals studied. There was a significant correlation (r=-0.961, P<0.01) between the expansion of the cytosine sequence length in the C-stretch of HVS-I and a reduction in the number of upstream adenines. These results indicate that the C-stretch could be a useful genetic maker in forensic identification of Chinese populations. The results from the Fst and dA genetic distance matrix, neighbor-joining tree, and principal component map also suggest that C-stretch could be used as a reliable genetic marker in population genetics.
HVS-based quantization steps for validation of digital cinema extended bitrates
NASA Astrophysics Data System (ADS)
Larabi, M.-C.; Pellegrin, P.; Anciaux, G.; Devaux, F.-O.; Tulet, O.; Macq, B.; Fernandez, C.
2009-02-01
In Digital Cinema, the video compression must be as transparent as possible to provide the best image quality to the audience. The goal of compression is to simplify transport, storing, distribution and projection of films. For all those tasks, equipments need to be developed. It is thus mandatory to reduce the complexity of the equipments by imposing limitations in the specifications. In this sense, the DCI has fixed the maximum bitrate for a compressed stream to 250 Mbps independently from the input format (4K/24fps, 2K/48fps or 2K/24fps). The work described in this paper This parameter is discussed in this paper because it is not consistent to double/quadruple the input rate without increasing the output rate. The work presented in this paper is intended to define quantization steps ensuring the visually lossless compression. Two steps are followed first to evaluate the effect of each subband separately and then to fin the scaling ratio. The obtained results show that it is necessary to increase the bitrate limit for cinema material in order to achieve the visually lossless.
Parker, H L; Tucker, E; Blackshaw, E; Hoad, C L; Marciani, L; Perkins, A; Menne, D; Fox, M
2017-11-01
Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study presents the reference intervals of the modular "Nottingham test meal" (NTM) for assessment of gastric function by gamma scintigraphy (GSc) in a representative population of healthy volunteers (HVs) stratified for age and sex. The NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and an optional solid component (12 solid agar-beads (0 kcal). Filling and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gamma scintigraphy parameters that describe early and late phase Gastric emptying (GE) were calculated from validated models. Gastric emptying (GE) of the liquid component was measured in 73 HVs (male 34; aged 45±20). The NTM produced normal postprandial fullness (VAS ≥30 in 41/74 subjects). Dyspeptic symptoms were rare (VAS ≥30 in 2/74 subjects). Gastric emptying half-time with the Liquid- and Solid-component -NTM was median 44 (95% reference interval 28-78) minutes and 162 (144-193) minutes, respectively. Gastric accommodation was assessed by the ratio of the liquid-NTM retained in the proximal:total stomach and by Early phase emptying assessed by gastric volume after completing the meal (GCV0). No consistent effect of anthropometric measures on GE parameters was present. Reference intervals are presented for GSc measurements of gastric motor and sensory function assessed by the NTM. Studies involving patients are required to determine whether the reference interval range offers optimal diagnostic sensitivity and specificity. © 2017 The Authors. Neurogastroenterology & Motility Published by John Wiley & Sons Ltd.
A new DWT/MC/DPCM video compression framework based on EBCOT
NASA Astrophysics Data System (ADS)
Mei, L. M.; Wu, H. R.; Tan, D. M.
2005-07-01
A novel Discrete Wavelet Transform (DWT)/Motion Compensation (MC)/Differential Pulse Code Modulation (DPCM) video compression framework is proposed in this paper. Although the Discrete Cosine Transform (DCT)/MC/DPCM is the mainstream framework for video coders in industry and international standards, the idea of DWT/MC/DPCM has existed for more than one decade in the literature and the investigation is still undergoing. The contribution of this work is twofold. Firstly, the Embedded Block Coding with Optimal Truncation (EBCOT) is used here as the compression engine for both intra- and inter-frame coding, which provides good compression ratio and embedded rate-distortion (R-D) optimization mechanism. This is an extension of the EBCOT application from still images to videos. Secondly, this framework offers a good interface for the Perceptual Distortion Measure (PDM) based on the Human Visual System (HVS) where the Mean Squared Error (MSE) can be easily replaced with the PDM in the R-D optimization. Some of the preliminary results are reported here. They are also compared with benchmarks such as MPEG-2 and MPEG-4 version 2. The results demonstrate that under specified condition the proposed coder outperforms the benchmarks in terms of rate vs. distortion.
Performance analysis of a new hypersonic vitrector system.
Stanga, Paulo Eduardo; Pastor-Idoate, Salvador; Zambrano, Isaac; Carlin, Paul; McLeod, David
2017-01-01
To evaluate porcine vitreous flow and water flow rates in a new prototype hypersonic vitrectomy system compared to currently available pneumatic guillotine vitrectors (GVs) systems. Two vitrectors were tested, a prototype, ultrasound-powered, hypersonic vitrector (HV) and a GV. Porcine vitreous was obtained within 12 to 24 h of sacrifice and kept at 4°C. A vial of vitreous or water was placed on a precision balance and its weight measured before and after the use of each vitrector. Test parameters included changes in aspiration levels, vitrector gauge, cut rates for GVs, % ultrasound (US) power for HVs, and port size for HVs. Data was analysed using linear regression and t-tests. There was no difference in the total average mean water flow between the 25-gauge GV and the 25-gauge HV (t-test: P = 0.363); however, 25-gauge GV was superior (t-test: P < 0.001) in vitreous flow. The 23-gauge GV was only more efficient in water and vitreous removal than 23-gauge HV needle-1 (Port 0.0055) (t-test: P < 0.001). For HV, wall thickness and gauge had no effect on flow rates. Water and vitreous flows showed a direct correlation with increasing aspiration levels and % US power (p<0.05). The HV produced consistent water and vitreous flow rates across the range of US power and aspiration levels tested. Hypersonic vitrectomy may be a promising new alternative to the currently available guillotine-based technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterling, D.A.; Roegner, K.C.; Lewis, R.D.
Childhood exposure to lead has been demonstrated to result in health effects and lead-contaminated household dust is a primary exposure source. There is a need to establish reliable methods for sampling surfaces to determine levels of lead contamination. Three vacuums (HVS3, GS80, and MVM) and one wipe method were evaluated for the collection of household floor dust under field sampling conditions within a Superfund site and demographically similar control area. Side-by-side floor samples were taken from three locations within 41 randomly selected households between August and September 1995: a child's bedroom, primary play area, and primary entrance. Analysis was performedmore » to assess the relative collection performance of each sampler, spatial distribution of lead within a household, and correlation of lead loading with observed blood lead level, and to determine if discrete or composites samples were more predictive of blood lead levels. Approximately 90% of the floor surfaces were carpeted. The rank order of sampling methods from greatest to lowest collection efficiency was HVS3 > G80 > wipe > MVM. The HVS3 had the highest level of precision (CV = 0.05), with the GS80 and wipe precisions 0.48 and 0.053, respectively.« less
Hamarat, Yasin; Deimantavicius, Mantas; Kalvaitis, Evaldas; Siaudvytyte, Lina; Januleviciene, Ingrida; Zakelis, Rolandas; Bartusis, Laimonas
2017-12-01
The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.
Turner, Alice M; Stolk, Jan; Bals, Robert; Lickliter, Jason D; Hamilton, James; Christianson, Dawn R; Given, Bruce D; Burdon, Jonathan G; Loomba, Rohit; Stoller, James K; Teckman, Jeffery H
2018-03-21
Alpha-1 antitrypsin deficiency (AATD) is a genetic disorder causing pulmonary and liver disease. The PiZ mutation in AAT (SERPINA1) results in mis-folded AAT protein (Z-AAT) accumulating in hepatocytes, leading to fibrosis and cirrhosis. RNAi-based therapeutics silencing production of hepatic Z-AAT might benefit patients with AATD-associated liver disease. This study evaluated an RNAi therapeutic to silence production of AAT. Part A of this double-blind first-in-human study randomized 54 healthy volunteers (HVs) into single dose cohorts (two placebo: four active), receiving escalating doses of the investigational agent ARC-AAT from 0.38 to 8.0 mg/kg or placebo. Part B randomized 11 patients with PiZZ (homozygous for Z-AAT) genotype AATD, who received up to 4.0 mg/kg of ARC-AAT or placebo. Patients with baseline FibroScan® >11 kPa or forced expiratory volume in one second (FEV1) <60% were excluded. Assessments included safety, pharmacokinetics, and change in serum AAT concentrations. A total of 36 HVs received ARC-AAT and 18 received placebo (part A). Seven PiZZ individuals received ARC-AAT and four received placebo (part B). A dose response in serum AAT reduction was observed at doses ≥4 mg/kg with similar relative reductions in PiZZ patients and HVs at 4 mg/kg and a maximum reduction of 76.1% (HVs) vs. 78.8% (PiZZ) at this dose. The time it took for serum AAT to return to baseline was similar for HV and PiZZ. There were no notable differences between HV and PiZZ safety parameters. The study was terminated early because of toxicity findings related to the delivery vehicle (ARC-EX1) seen in a non-human primate study. PiZZ patients and HVs responded similarly to ARC-AAT. Deep and durable knockdown of hepatic AAT production based on observed reduction in serum AAT concentrations was demonstrated. Accumulation of abnormal proteins in the livers of patients with alpha-1 antitrypsin deficiency may lead to decreased liver function and potentially liver failure. Therapeutics targeting the production of these abnormal proteins may be used to prevent or treat liver disease in patients with alpha-1 antitrypsin deficiency. NCT02363946. Copyright © 2018 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
Spotting and tracking good biometrics with the human visual system
NASA Astrophysics Data System (ADS)
Szu, Harold; Jenkins, Jeffrey; Hsu, Charles
2011-06-01
We mathematically model the mammalian Visual System's (VS) capability of spotting objects. How can a hawk see a tiny running rabbit from miles above ground? How could that rabbit see the approaching hawk? This predatorprey interaction draws parallels with spotting a familiar person in a crowd. We assume that mammal eyes use peripheral vision to perceive unexpected changes from our memory, and then use our central vision (fovea) to pay attention. The difference between an image and our memory of that image is usually small, mathematically known as a 'sparse representation'. The VS communicates with the brain using a finite reservoir of neurotransmittents, which produces an on-center and thus off-surround Hubel/Wiesel Mexican hat receptive field. This is the basis of our model. This change detection mechanism could drive our attention, allowing us to hit a curveball. If we are about to hit a baseball, what information extracted by our HVS tells us where to swing? Physical human features such as faces, irises, and fingerprints have been successfully used for identification (Biometrics) for decades, recently including voice and walking style for identification from further away. Biologically, humans must use a change detection strategy to achieve an ordered sparseness and use a sigmoid threshold for noisy measurements in our Hetero-Associative Memory [HAM] classifier for fault tolerant recall. Human biometrics is dynamic, and therefore involves more than just the surface, requiring a 3 dimensional measurement (i.e. Daugman/Gabor iris features). Such a measurement can be achieved using the partial coherence of a laser's reflection from a 3-D biometric surface, creating more degrees of freedom (d.o.f.) to meet the Army's challenge of distant Biometrics. Thus, one might be able to increase the standoff loss of less distinguished degrees of freedom (DOF).
Althumairi, Azah A; Canner, Joseph K; Gorin, Michael A; Fang, Sandy H; Gearhart, Susan L; Wick, Elizabeth C; Safar, Bashar; Bivalacqua, Trinity J; Efron, Jonathan E
2016-01-01
High volume hospitals (HVHs) and high volume surgeons (HVSs) have better outcomes after complex procedures, but the association between surgeon and hospital volumes and patient outcomes is not completely understood. Our aim was to evaluate the impact of surgeon and hospital volumes, and their interaction, on postoperative outcomes and costs in patients undergoing pelvic exenteration (PE) in the state of Maryland. A review of the Maryland Health Services Cost Review Commission database between 2000 and 2011 was performed. Patients were compared for demographics and clinical variables. The differences in length of hospital stay , length of intensive care unit (ICU) stay, operating room (OR) cost, and total cost were compared for surgeon volume and hospital volume controlling for all other factors. Surgery performed by HVS at HVH had the shortest ICU stay and lowest OR cost. When PE was performed by a low volume surgeon at an HVH, the OR cost and total cost were the highest and increased by $2,683 (P < 0.0001) and $16,076 (P < 0.0001), respectively. OR costs reduced when surgery was performed by an HVS at an HVH ($-1632, P = 0.008). PE performed by HVS at HVH is significantly associated with lower OR costs and ICU stay. We feel this is indicative of lower complication rates and higher quality care.
Takano, S; Sogawa, K; Yoshitomi, H; Shida, T; Mogushi, K; Kimura, F; Shimizu, H; Yoshidome, H; Ohtsuka, M; Kato, A; Ishihara, T; Tanaka, H; Yokosuka, O; Nomura, F; Miyazaki, M
2010-01-01
Background: Intracellular phosphoprotein activation significantly regulates cancer progression. However, the significance of circulating phosphoproteins in the blood remains unknown. We investigated the serum phosphoprotein profile involved in pancreatic cancer (PaCa) by a novel approach that comprehensively measured serum phosphoproteins levels, and clinically applied this method to the detection of PaCa. Methods: We analysed the serum phosphoproteins that comprised cancer cellular signal pathways by comparing sera from PaCa patients and benign controls including healthy volunteers (HVs) and pancreatitis patients. Results: Hierarchical clustering analysis between PaCa patients and HVs revealed differential pathway-specific profiles. In particular, the components of the extracellular signal-regulated kinase (ERK) signalling pathway were significantly increased in the sera of PaCa patients compared with HVs. The positive rate of p-ERK1/2 (82%) was found to be superior to that of CA19-9 (53%) for early stage PaCa. For the combination of these serum levels, the area under the receiver-operator characteristics curves was showing significant ability to distinguish between the two populations in independent validation set, and between cancer and non-cancer populations in another validation set. Conclusion: The comprehensive measurement of serum cell signal phosphoproteins is useful for the detection of PaCa. Further investigations will lead to the implementation of tailor-made molecular-targeted therapeutics. PMID:20551957
Aubyn, Gloria Baaba; Tagoe, Daniel Nii Aryee
2013-01-01
Objective To determine the prevalence of vaginal infections and associated lifestyles of students visiting the University of Cape Coast Hospital. Methods Fifty female students presenting with clinical symptoms of vaginitis were sampled. One hundred samples made up of 50 urine and 50 higher vaginal swabs (HVS) were obtained from patients and questionnaire administered. Samples were wet prepared, examined microscopically, and cultured on blood and chocolate agars for 24 h at (35±2) °C. Colonial morphology, Gram reactions and biochemical tests were used for the identification of isolates. Results There were high percentages of pus cells (64%), epithelial cells (62%) and yeast cells (56%) in all urine samples. Bacterial isolates included Staphylococcus aureus (28%) and (22%), Klebsiella spp. (6%) and (4%) in urine and HVS samples respectively; Escherichia coli in urine (18%) and Candida in HVS (16%). The overall prevalence of vaginitis was 66%, including bacterial vaginosis 28%, Candida infection 22% and co-infection of bacterial and Candida 16%. Lifestyle data showed all sampled students were sexually active, 48% used contraceptives, 54% used antimicrobial agents, and 92% prefered wearing of trousers and shorts. Conclusions The present study indicates prevalence of vaginal infection among female students, which strongly correlates with student lifestyle. Education on lifestyle modifications will go a long way in reducing the prevalence of vaginitis.
Neonatal sepsis due to vertical transmission from maternal genital tract.
Ayengar, V; Madhulika; Vani, S N
1991-01-01
High vaginal swabs (HVS) of 1792 expectant mothers were sent for culture at the time of delivery, prior to first vaginal examination. The newborns were followed-up for development of superficial or deep infections. Appropriate cultures of the babies who developed infections were sent. Bacterial growth of predominantly gram-ve organisms was obtained in 1026 (57%) HVS. Infection developed in 48 (27%) babies in 1st 72 hours of life, of which 28 had deep infection while the rest had superficial infection. Vertical transmission of organisms was documented in 24 (1.3%) mother-baby dyads and the same was 72% in newborns who were at risk of developing sepsis by septicemia scoring, showing a significantly higher incidence of vertical transmission and subsequent sepsis in high risk newborns.
NASA Astrophysics Data System (ADS)
Dijk, J.; Bijl, P.; Oppeneer, M.; ten Hove, R. J. M.; van Iersel, M.
2017-10-01
The Electro-Optical Signal Transmission and Ranging (EOSTAR) model is an image-based Tactical Decision Aid (TDA) for thermal imaging systems (MWIR/LWIR) developed for a sea environment with an extensive atmosphere model. The Triangle Orientation Discrimination (TOD) Target Acquisition model calculates the sensor and signal processing effects on a set of input triangle test pattern images, judges their orientation using humans or a Human Visual System (HVS) model and derives the system image quality and operational field performance from the correctness of the responses. Combination of the TOD model and EOSTAR, basically provides the possibility to model Target Acquisition (TA) performance over the exact path from scene to observer. In this method ship representative TOD test patterns are placed at the position of the real target, subsequently the combined effects of the environment (atmosphere, background, etc.), sensor and signal processing on the image are calculated using EOSTAR and finally the results are judged by humans. The thresholds are converted into Detection-Recognition-Identification (DRI) ranges of the real target. In experiments is shown that combination of the TOD model and the EOSTAR model is indeed possible. The resulting images look natural and provide insight in the possibilities of combining the two models. The TOD observation task can be done well by humans, and the measured TOD is consistent with analytical TOD predictions for the same camera that was modeled in the ECOMOS project.
Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J
2017-07-25
Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be adjusted and other respiratory function tests such as SNIP and PCF may become part of routine care in patients with ALS in order to avoid non-timely initiation of (non-invasive) ventilation.
Model-based VQ for image data archival, retrieval and distribution
NASA Technical Reports Server (NTRS)
Manohar, Mareboyana; Tilton, James C.
1995-01-01
An ideal image compression technique for image data archival, retrieval and distribution would be one with the asymmetrical computational requirements of Vector Quantization (VQ), but without the complications arising from VQ codebooks. Codebook generation and maintenance are stumbling blocks which have limited the use of VQ as a practical image compression algorithm. Model-based VQ (MVQ), a variant of VQ described here, has the computational properties of VQ but does not require explicit codebooks. The codebooks are internally generated using mean removed error and Human Visual System (HVS) models. The error model assumed is the Laplacian distribution with mean, lambda-computed from a sample of the input image. A Laplacian distribution with mean, lambda, is generated with uniform random number generator. These random numbers are grouped into vectors. These vectors are further conditioned to make them perceptually meaningful by filtering the DCT coefficients from each vector. The DCT coefficients are filtered by multiplying by a weight matrix that is found to be optimal for human perception. The inverse DCT is performed to produce the conditioned vectors for the codebook. The only image dependent parameter used in the generation of codebook is the mean, lambda, that is included in the coded file to repeat the codebook generation process for decoding.
Wang, Fengqing; Zhi, Jingyu; Zhang, Zhongyi; Wang, Lina; Suo, Yanfei; Xie, Caixia; Li, Mingjie; Zhang, Bao; Du, Jiafang; Gu, Li; Sun, Hongzheng
2017-01-01
Rehmannia glutinosa is a common bulk medicinal material that has been widely used in China due to its active ingredients. Acteoside, one of the ingredients, has antioxidant, antinephritic, anti-inflammatory, hepatoprotective, immunomodulatory, and neuroprotective effects, is usually selected as a quality-control component for R. glutinosa herb in the Chinese Pharmacopeia. The acteoside biosynthesis pathway in R. glutinosa has not yet been clearly established. Herein, we describe the establishment of a genetic transformation system for R. glutinosa mediated by Agrobacterium rhizogenes. We screened the optimal elicitors that markedly increased acteoside accumulation in R. glutinosa hairy roots. We found that acteoside accumulation dramatically increased with the addition of salicylic acid (SA); the optimal SA dose was 25 μmol/L for hairy roots. RNA-seq was applied to analyze the transcriptomic changes in hairy roots treated with SA for 24 h in comparison with an untreated control. A total of 3,716, 4,018, and 2,715 differentially expressed transcripts (DETs) were identified in 0 h-vs.-12 h, 0 h-vs.-24 h, and 12 h-vs.-24 h libraries, respectively. KEGG pathway-based analysis revealed that 127 DETs were enriched in “phenylpropanoid biosynthesis.” Of 219 putative unigenes involved in acteoside biosynthesis, 54 were found to be up-regulated at at least one of the time points after SA treatment. Selected candidate genes were analyzed by quantitative real-time PCR (qRT-PCR) in hairy roots with SA, methyl jasmonate (MeJA), AgNO3 (Ag+), and putrescine (Put) treatment. All genes investigated were up-regulated by SA treatment, and most candidate genes were weakly increased by MeJA to some degree. Furthermore, transcription abundance of eight candidate genes in tuberous roots of the high-acteoside-content (HA) cultivar QH were higher than those of the low-acteoside-content (LA) cultivar Wen 85-5. These results will pave the way for understanding the molecular basis of acteoside biosynthesis in R. glutinosa, and can serve as a basis for future validation studies. PMID:28567046
Parker, H L; Tucker, E; Hoad, C L; Pal, A; Costigan, C; Hudders, N; Perkins, A; Blackshaw, E; Gowland, P; Marciani, L; Fox, M R
2016-04-01
Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study introduces the large 'Nottingham Test Meal' (NTM) for assessment of gastric motor and sensory function by non-invasive imaging. NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and 12 solid agar-beads (0 kcal) with known breaking strength. Gastric fullness and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gastric emptying (GE) were measured in 24 healthy volunteers (HVs) by gastric scintigraphy (GS) and magnetic resonance imaging (MRI). The contribution of secretion to gastric volume was assessed. Parameters that describe GE were calculated from validated models. Inter-observer agreement and reproducibility were assessed. NTM produced moderate fullness (VAS ≥30) but no more than mild dyspeptic symptoms (VAS <30) in 24 HVs. Stable binding of meal components to labels in gastric conditions was confirmed. Distinct early and late-phase GE were detected by both modalities. Liquid GE half-time was median 49 (95% CI: 36-62) min and 68 (57-71) min for GS and MRI, respectively. Differences between GS and MRI measurements were explained by the contribution of gastric secretion. Breaking strength for agar-beads was 0.8 N/m(2) such that median 25 (8-50) % intact agar-beads and 65 (47-74) % solid material remained at 120 min on MRI and GS, respectively. Good reproducibility for liquid GE parameters was present and GE was not altered by agar-beads. The NTM provided an objective assessment of gastric motor and sensory function. The results were reproducible and liquid emptying was not affected by non-nutrient agar-beads. The method is potentially suitable for clinical practice. © 2016 John Wiley & Sons Ltd.
Berger, C; Berger, B; Parson, W
2012-01-01
In recent years, evidence from domestic dogs has increasingly been analyzed by forensic DNA testing. Especially, canine hairs have proved most suitable and practical due to the high rate of hair transfer occurring between dogs and humans. Starting with the description of a contamination-free sample handling procedure, we give a detailed workflow for sequencing hypervariable segments (HVS) of the mtDNA control region from canine evidence. After the hair material is lysed and the DNA extracted by Phenol/Chloroform, the amplification and sequencing strategy comprises the HVS I and II of the canine control region and is optimized for DNA of medium-to-low quality and quantity. The sequencing procedure is based on the Sanger Big-dye deoxy-terminator method and the separation of the sequencing reaction products is performed on a conventional multicolor fluorescence detection capillary electrophoresis platform. Finally, software-aided base calling and sequence interpretation are addressed exemplarily.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenyon, Scott J.; Brown, Warren R.; Geller, Margaret J.
We predict the distinctive three-dimensional space motions of hypervelocity stars (HVSs) and runaway stars moving in a realistic Galactic potential. For nearby stars with distances less than 10 kpc, unbound stars are rare; proper motions alone rarely isolate bound HVSs and runaways from indigenous halo stars. At large distances of 20-100 kpc, unbound HVSs are much more common than runaways; radial velocities easily distinguish both from indigenous halo stars. Comparisons of the predictions with existing observations are encouraging. Although the models fail to match observations of solar-type HVS candidates from SEGUE, they agree well with data for B-type HVS andmore » runaways from other surveys. Complete samples of g ≲ 20 stars with Gaia should provide clear tests of formation models for HVSs and runaways and will enable accurate probes of the shape of the Galactic potential.« less
Stellar dynamics. The fastest unbound star in our Galaxy ejected by a thermonuclear supernova.
Geier, S; Fürst, F; Ziegerer, E; Kupfer, T; Heber, U; Irrgang, A; Wang, B; Liu, Z; Han, Z; Sesar, B; Levitan, D; Kotak, R; Magnier, E; Smith, K; Burgett, W S; Chambers, K; Flewelling, H; Kaiser, N; Wainscoat, R; Waters, C
2015-03-06
Hypervelocity stars (HVSs) travel with velocities so high that they exceed the escape velocity of the Galaxy. Several acceleration mechanisms have been discussed. Only one HVS (US 708, HVS 2) is a compact helium star. Here we present a spectroscopic and kinematic analysis of US 708. Traveling with a velocity of ~1200 kilometers per second, it is the fastest unbound star in our Galaxy. In reconstructing its trajectory, the Galactic center becomes very unlikely as an origin, which is hardly consistent with the most favored ejection mechanism for the other HVSs. Furthermore, we detected that US 708 is a fast rotator. According to our binary evolution model, it was spun-up by tidal interaction in a close binary and is likely to be the ejected donor remnant of a thermonuclear supernova. Copyright © 2015, American Association for the Advancement of Science.
Image quality evaluation of full reference algorithm
NASA Astrophysics Data System (ADS)
He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan
2018-03-01
Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.
Elevated urinary podocyte-derived extracellular microvesicles in renovascular hypertensive patients
Kwon, Soon Hyo; Woollard, John R.; Saad, Ahmed; Garovic, Vesna D.; Zand, Ladan; Jordan, Kyra L.; Textor, Stephen C.
2017-01-01
ABSTRACT Background: An increased number of podocyte-derived extracellular vesicles (pEVs) may reflect podocyte injury in renal disease. Elevated glomerular pressure and other insults may injure podocytes, yet it remains unclear whether the numbers of pEVs are altered in hypertensive patients. We tested the hypothesis that urinary pEV levels would be elevated in patients with renovascular hypertension (RVH) compared with essential hypertension (EH) or healthy volunteers (HVs). Methods: We prospectively enrolled patients with EH (n = 30) or RVH (n = 31) to study renal blood flow (RBF) and cortical perfusion using multidetector computed tomography under controlled condition (regulated sodium intake and renin—angiotensin blockade). After isolation from urine samples, pEVs (nephrin and podocalyxin positive) were characterized by flow cytometry. Fourteen RVH patients were studied again 3 months after stenting or continued medical therapy. HVs (n = 15) served as controls. Results: The fraction of pEV among urinary EVs was elevated in RVH compared with HVs and EH (11.4 ± 6.4, 6.8 ± 3.4 and 6.3 ± 3.7%, respectively; P < 0.001) and remained unchanged after 3 additional months of therapy and after controlling for clinical parameters. However, eGFR- and age-adjusted pEV levels did not correlate with any clinical or renal parameters. Conclusions: In hypertensive patients under controlled conditions, urinary pEV levels are elevated in patients with RVH and low eGFR compared with patients with EH and relatively preserved renal function. These pEVs may reflect podocyte injury secondary to kidney damage, and their levels might represent a novel therapeutic target. PMID:27190371
Adachi, Noboru; Umetsu, Kazuo; Shojo, Hideki
2014-01-01
Mitochondrial DNA (mtDNA) is widely used for DNA analysis of highly degraded samples because of its polymorphic nature and high number of copies in a cell. However, as endogenous mtDNA in deteriorated samples is scarce and highly fragmented, it is not easy to obtain reliable data. In the current study, we report the risks of direct sequencing mtDNA in highly degraded material, and suggest a strategy to ensure the quality of sequencing data. It was observed that direct sequencing data of the hypervariable segment (HVS) 1 by using primer sets that generate an amplicon of 407 bp (long-primer sets) was different from results obtained by using newly designed primer sets that produce an amplicon of 120-139 bp (mini-primer sets). The data aligned with the results of mini-primer sets analysis in an amplicon length-dependent manner; the shorter the amplicon, the more evident the endogenous sequence became. Coding region analysis using multiplex amplified product-length polymorphisms revealed the incongruence of single nucleotide polymorphisms between the coding region and HVS 1 caused by contamination with exogenous mtDNA. Although the sequencing data obtained using long-primer sets turned out to be erroneous, it was unambiguous and reproducible. These findings suggest that PCR primers that produce amplicons shorter than those currently recognized should be used for mtDNA analysis in highly degraded samples. Haplogroup motif analysis of the coding region and HVS should also be performed to improve the reliability of forensic mtDNA data. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Hiding Information Using different lighting Color images
NASA Astrophysics Data System (ADS)
Majead, Ahlam; Awad, Rash; Salman, Salema S.
2018-05-01
The host medium for the secret message is one of the important principles for the designers of steganography method. In this study, the best color image was studied to carrying any secret image.The steganography approach based Lifting Wavelet Transform (LWT) and Least Significant Bits (LSBs) substitution. The proposed method offers lossless and unnoticeable changes in the contrast carrier color image and imperceptible by human visual system (HVS), especially the host images which was captured in dark lighting conditions. The aim of the study was to study the process of masking the data in colored images with different light intensities. The effect of the masking process was examined on the images that are classified by a minimum distance and the amount of noise and distortion in the image. The histogram and statistical characteristics of the cover image the results showed the efficient use of images taken with different light intensities in hiding data using the least important bit substitution method. This method succeeded in concealing textual data without distorting the original image (low light) Lire developments due to the concealment process.The digital image segmentation technique was used to distinguish small areas with masking. The result is that smooth homogeneous areas are less affected as a result of hiding comparing with high light areas. It is possible to use dark color images to send any secret message between two persons for the purpose of secret communication with good security.
Video coding for 3D-HEVC based on saliency information
NASA Astrophysics Data System (ADS)
Yu, Fang; An, Ping; Yang, Chao; You, Zhixiang; Shen, Liquan
2016-11-01
As an extension of High Efficiency Video Coding ( HEVC), 3D-HEVC has been widely researched under the impetus of the new generation coding standard in recent years. Compared with H.264/AVC, its compression efficiency is doubled while keeping the same video quality. However, its higher encoding complexity and longer encoding time are not negligible. To reduce the computational complexity and guarantee the subjective quality of virtual views, this paper presents a novel video coding method for 3D-HEVC based on the saliency informat ion which is an important part of Human Visual System (HVS). First of all, the relationship between the current coding unit and its adjacent units is used to adjust the maximum depth of each largest coding unit (LCU) and determine the SKIP mode reasonably. Then, according to the saliency informat ion of each frame image, the texture and its corresponding depth map will be divided into three regions, that is, salient area, middle area and non-salient area. Afterwards, d ifferent quantization parameters will be assigned to different regions to conduct low complexity coding. Finally, the compressed video will generate new view point videos through the renderer tool. As shown in our experiments, the proposed method saves more bit rate than other approaches and achieves up to highest 38% encoding time reduction without subjective quality loss in compression or rendering.
NASA Astrophysics Data System (ADS)
Cvetkovic, Sascha D.; Schirris, Johan; de With, Peter H. N.
2009-01-01
For real-time imaging in surveillance applications, visibility of details is of primary importance to ensure customer confidence. If we display High Dynamic-Range (HDR) scenes whose contrast spans four or more orders of magnitude on a conventional monitor without additional processing, results are unacceptable. Compression of the dynamic range is therefore a compulsory part of any high-end video processing chain because standard monitors are inherently Low- Dynamic Range (LDR) devices with maximally two orders of display dynamic range. In real-time camera processing, many complex scenes are improved with local contrast enhancements, bringing details to the best possible visibility. In this paper, we show how a multi-scale high-frequency enhancement scheme, in which gain is a non-linear function of the detail energy, can be used for the dynamic range compression of HDR real-time video camera signals. We also show the connection of our enhancement scheme to the processing way of the Human Visual System (HVS). Our algorithm simultaneously controls perceived sharpness, ringing ("halo") artifacts (contrast) and noise, resulting in a good balance between visibility of details and non-disturbance of artifacts. The overall quality enhancement, suitable for both HDR and LDR scenes, is based on a careful selection of the filter types for the multi-band decomposition and a detailed analysis of the signal per frequency band.
Meier, Elisabeth M; Pohl, Rebekka; Rein-Fischboeck, Lisa; Schacherer, Doris; Eisinger, Kristina; Wiest, Reiner; Krautbauer, Sabrina; Buechler, Christa
2016-09-01
Lipocalin 2 (LCN2) is induced in the injured liver and associated with inflammation. Aim of the present study was to evaluate whether serum LCN2 is a non-invasive marker to assess hepatic steatosis in patients with non-alcoholic fatty liver disease (NAFLD) or residual liver function in patients with liver cirrhosis. Therefore, LCN2 was measured by ELISA in serum of 32 randomly selected patients without fatty liver (controls), 24 patients with ultrasound diagnosed NAFLD and 42 patients with liver cirrhosis mainly due to alcohol. Systemic LCN2 was comparable in patients with liver steatosis, those with liver cirrhosis and controls. LCN2 negatively correlated with bilirubin in both cohorts. In cirrhosis, LCN2 was not associated with more advanced liver injury defined by the CHILD-PUGH score and model for end-stage liver disease score. Resistin but not C-reactive protein or chemerin positively correlated with LCN2. LCN2 levels were not increased in patients with ascites or patients with esophageal varices. Consequently, reduction of portal pressure by transjugular intrahepatic portosystemic shunt did not affect LCN2 levels. Hepatic venous blood (HVS), portal venous blood and systemic venous blood levels of LCN2 were similar. HVS LCN2 was unchanged in patients with end-stage liver cirrhosis compared to those with well-compensated disease arguing against increased hepatic release. Current data exclude that serum LCN2 is of any value as steatosis marker in patients with NAFLD and indicator of liver function in patients with alcoholic liver cirrhosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Impact of podiatry resident experience level in hallux valgus surgery on postoperative outcomes.
Fleischer, Adam E; Yorath, Martin C; Joseph, Robert M; Baron, Adam; Nordquist, Thomas; Moore, Braden J; Robinson, Richmond C O; Reilly, Charles H
2014-06-15
Despite modern advancements in transosseous fixation and operative technique, hallux valgus (i.e., bunion) surgery is still associated with a higher than usual amount of patient dissatisfaction and is generally recognized as a complex and nuanced procedure requiring precise osseous and capsulotendon balancing. It stands to reason then that familiarity and skill level of trainee surgeons might impact surgical outcomes in this surgery. The aim of this study was to determine whether podiatry resident experience level influences midterm outcomes in hallux valgus surgery (HVS). Consecutive adults who underwent isolated HVS via distal metatarsal osteotomy at a single US metropolitan teaching hospital from January 2004 to January 2009 were contacted and asked to complete a validated outcome measure of foot health (Manchester-Oxford Foot Questionnaire) regarding their operated foot. Resident experience level was quantified using the surgical logs for the primary resident of record at the time of each case. Associations were assessed using linear and logistic regression analyses. A total of 102 adult patients (n = 102 feet) agreed to participate with a mean age of 46.8 years (standard deviation 13.1, range 18-71) and average length of follow-up 6.2 y (standard deviation 1.4, range 3.6-8.6). Level of trainee experience was not associated with postoperative outcomes in either the univariate (odds ratio 0.99 [95% confidence interval, 0.98-1.01], P = 0.827) or multivariate analyses (odds ratio 1.00 [95% confidence interval, 0.97-1.02], P = 0.907). We conclude that podiatry resident level of experience in HVS does not contribute appreciably to postoperative clinical outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.
Martin-Bastida, A; Lao-Kaim, N P; Loane, C; Politis, M; Roussakis, A A; Valle-Guzman, N; Kefalopoulou, Z; Paul-Visse, G; Widner, H; Xing, Y; Schwarz, S T; Auer, D P; Foltynie, T; Barker, R A; Piccini, P
2017-02-01
To determine whether iron deposition in deep brain nuclei assessed using high-pass filtered phase imaging plays a role in motor disease severity in Parkinson's disease (PD). Seventy patients with mild to moderate PD and 20 age- and gender-matched healthy volunteers (HVs) underwent susceptibility-weighted imaging on a 3 T magnetic resonance imaging scanner. Phase shifts (radians) in deep brain nuclei were derived from high-pass filtered phase images and compared between groups. Analysis of clinical laterality and correlations with motor severity (Unified Parkinson's Disease Rating Scale, Part III, UPDRS-III) were performed. Phase shifts (in radians) were compared between HVs and three PD subgroups divided according to UPDRS-III scores using analysis of covariance, adjusting for age and regional area. Parkinson's disease patients had significantly (P < 0.001) higher radians than HVs bilaterally in the putamen, globus pallidus and substantia nigra (SN). The SN contralateral to the most affected side showed higher radians (P < 0.001) compared to the less affected side. SN radians positively correlated with UPDRS-III and bradykinesia-rigidity subscores, but not with tremor subscores. ancova followed by post hoc Bonferroni-adjusted pairwise comparisons revealed that SN radians were significantly greater in the PD subgroup with higher UPDRS-III scores compared to both lowest UPDRS-III PD and HV groups (P < 0.001). Increased nigral iron accumulation in PD appears to be stratified according to disease motor severity and correlates with symptoms related to dopaminergic neurodegeneration. This semi-quantitative in vivo iron assessment could prove useful for objectively monitoring PD progression, especially in clinical trials concerning iron chelation therapies. © 2016 EAN.
Temporal lobe epilepsy and affective disorders: the role of the subgenual anterior cingulate cortex.
Stretton, J; Pope, R A; Winston, G P; Sidhu, M K; Symms, M; Duncan, J S; Koepp, M; Thompson, P J; Foong, J
2015-02-01
Reduced deactivation within the default mode network (DMN) is common in individuals with primary affective disorders relative to healthy volunteers (HVs). It is unknown whether similar network abnormalities are present in temporal lobe epilepsy (TLE) patients with a history of affective psychopathology. 17 TLE patients with a lifetime affective diagnosis, 31 TLE patients with no formal psychiatric history and 30 HVs were included. We used a visuo-spatial 'n-back' paradigm to compare working memory (WM) network activation between these groups. Post hoc analyses included voxel-based morphometry and diffusion tensor imaging. The Beck Depression Inventory-Fast Screen and Beck Anxiety Inventory were completed on the day of scanning. Each group activated the fronto-parietal WM networks and deactivated the typical DMN in response to increasing task demands. Group comparison revealed that TLE patients with lifetime affective morbidity showed significantly greater deactivation in subgenual anterior cingulate cortex (sACC) than either the TLE-only or the HVs (p<0.001). This effect persisted after covarying for current psychotropic medication and severity of current depressive/anxiety symptoms (all p<0.001). Correlational analysis revealed that this finding was not driven by differences in task performance. There were no significant differences in grey matter volume or structural connectivity between the TLE groups. Our results provide novel evidence suggesting that affective psychopathology in TLE has a neurobiological correlate, and in this context the sACC performs differently compared with network activity in primary affective disorders. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Cerebral metabolic abnormalities in A3243G mitochondrial DNA mutation carriers
Weiduschat, Nora; Kaufmann, Petra; Mao, Xiangling; Engelstad, Kristin Marie; Hinton, Veronica; DiMauro, Salvatore; De Vivo, Darryl
2014-01-01
Objective: To establish cerebral metabolic features associated with the A3243G mitochondrial DNA mutation with proton magnetic resonance spectroscopic imaging (1H MRSI) and to assess their potential as prognostic biomarkers. Methods: In this prospective cohort study, we investigated 135 clinically heterogeneous A3243G mutation carriers and 30 healthy volunteers (HVs) with 1H MRSI. Mutation carriers included 45 patients with mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes (MELAS); 11 participants who would develop the MELAS syndrome during follow-up (converters); and 79 participants who would not develop the MELAS syndrome during follow-up (nonconverters). The groups were compared with respect to MRSI metabolic indices of 1) anaerobic energy metabolism (lactate), 2) neuronal integrity (N-acetyl-l-aspartate [NAA]), 3) mitochondrial function (NAA; lactate), 4) cell energetics (total creatine), and 5) membrane biosynthesis and turnover (total choline [tCho]). Results: Consistent with prior studies, the patients with MELAS had higher lactate (p < 0.001) and lower NAA levels (p = 0.01) than HVs. Unexpectedly, converters showed higher NAA (p = 0.042), tCho (p = 0.004), and total creatine (p = 0.002), in addition to higher lactate levels (p = 0.032), compared with HVs. Compared with nonconverters, converters had higher tCho (p = 0.015). Clinically, converters and nonconverters did not differ at baseline. Lactate and tCho levels were reliable biomarkers for predicting the risk of individual mutation carriers to develop the MELAS phenotype. Conclusions: 1H MRSI assessment of cerebral metabolism in A3243G mutation carriers shows promise in identifying disease biomarkers as well as individuals at risk of developing the MELAS phenotype. PMID:24477106
Beaumont, Hanneke; Bennink, Roelof J; de Jong, Jan; Boeckxstaens, Guy E
2010-04-01
Gastro-oesophageal reflux occurs twice as much during transient lower oesophageal sphincter relaxations (TLOSRs) in patients with gastro-oesophageal reflux disease (GORD) compared to healthy volunteers (HVs). Our aim was to assess whether the localisation of the postprandial acid pocket and its interaction with a hiatal hernia (HH) play a role in the occurrence of acidic reflux during TLOSRs. Ten HVs and 22 patients with GORD (12 with HH<3 cm (s-HH), 10 with HH > or =3 cm (l-HH)) were studied. The squamocolumnar junction and diaphragmatic impression were marked with a radioactively labelled clip. To visualise the acid pocket, (99m)Tc-pertechnetate was injected intravenously and images were acquired up to 2 h postprandial. Concurrently, combined manometry/impedance and four-channel pH-metry were performed, with pH pull-through at multiple time-points. The rate of TLOSRs and the per cent associated with reflux was comparable between all groups. However, acidic reflux was significantly increased in patients, especially in patients with l-HH. Acid pocket length was significantly enlarged in patients. Moreover, immediately before a TLOSR, the acid pocket was more frequently located within the hiatus or above the diaphragm in patients with GORD (s-HH, 54%; l-HH, 77%) compared to HVs (22% of TLOSRs). Acidic reflux was significantly increased when the acid pocket was located above the diaphragm in all groups compared to a sub-diaphragmatic localisation. The position of the acid pocket is largely determined by the presence of a HH. Entrapment of the pocket above the diaphragm, especially in patients with l-HH, is a major risk factor underlying the increased occurrence of acidic reflux during a TLOSR in patients with GORD.
Deziel, NC; Rull, RP; Colt, JS; Reynolds, P; Whitehead, TP; Gunier, RB; Month, SR; Taggart, DR; Buffler, P; Ward, MH; Metayer, C
2014-01-01
Several polycyclic aromatic hydrocarbons (PAHs) are known or probable human carcinogens. We evaluated the relationship between PAH exposure and risk of childhood acute lymphoblastic leukemia (ALL) using concentrations in residential dust as an exposure indicator. We conducted a population-based case-control study (251 ALL cases, 306 birth-certificate controls) in Northern and Central California from 2001–2007. We collected residential dust using a high volume small surface sampler (HVS3) (n=185 cases, 212 controls) or by sampling from participants’ household vacuum cleaners (n=66 cases, 94 controls). We evaluated log-transformed concentrations of 9 individual PAHs, the summed PAHs, and the summed PAHs weighted by their carcinogenic potency (the toxic equivalence). We calculated odds ratios (ORs) and 95% confidence intervals (CI) using logistic regression adjusting for demographic characteristics and duration between diagnosis/reference date and dust collection. Among participants with HVS3 dust, risk of ALL was not associated with increasing concentration of any PAHs (based on OR per ln(ng/g). Among participants with vacuum dust, we observed positive associations between ALL risk and increasing concentrations of benzo[a]pyrene (OR per ln[ng/g]=1.42, 95% CI=0.95, 2.12), dibenzo[a,h]anthracene (OR=1.98, 95% CI=1.11, 3.55), benzo[k]fluoranthene (OR=1.71, 95% CI= 0.91, 3.22), indeno[1,2,3-cd]pyrene (OR=1.81, 95% CI=1.04, 3.16), and the toxic equivalence (OR=2.35, 95% CI=1.18, 4.69). The increased ALL risk among participants with vacuum dust suggests that PAH exposure may increase the risk of childhood ALL; however, reasons for the different results based on HVS3 dust samples deserve further study. PMID:24948546
Marciani, L; Garsed, K C; Hoad, C L; Fields, A; Fordham, I; Pritchard, S E; Placidi, E; Murray, K; Chaddock, G; Costigan, C; Lam, C; Jalanka-Tuovinen, J; De Vos, W M; Gowland, P A; Spiller, R C
2014-01-01
Background Most methods of assessing colonic motility are poorly acceptable to patients. Magnetic resonance imaging (MRI) can monitor gastrointestinal motility and fluid distributions. We predicted that a dose of oral polyethylene glycol (PEG) and electrolyte solution would increase ileo-colonic inflow and stimulate colonic motility. We aimed to investigate the colonic response to distension by oral PEG electrolyte in healthy volunteers (HVs) and to evaluate the effect of single 2 L vs split (2 × 1 L) dosing. Methods Twelve HVs received a split dose (1 L the evening before and 1 L on the study day) and another 12 HVs a single dose (2 L on the main study day) of PEG electrolyte. They underwent MRI scans, completed symptom questionnaires, and provided stool samples. Outcomes included small bowel water content, ascending colon motility index, and regional colonic volumes. Key Results Small bowel water content increased fourfold from baseline after ingesting both split (p = 0.0010) and single dose (p = 0.0005). The total colonic volume increase from baseline was smaller for the split dose at 35 ± 8% than for the single dose at 102 ± 27%, p = 0.0332. The ascending colon motility index after treatment was twofold higher for the single dose group (p = 0.0103). Conclusions & Inferences Ingestion of 1 and 2 L PEG electrolyte solution caused a rapid increase in the small bowel and colonic volumes and a robust rise in colonic motility. The increase in both volumes and motility was dose dependent. Such a challenge, being well-tolerated, could be a useful way of assessing colonic motility in future studies. PMID:25060551
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
... DEPARTMENT OF COMMERCE U.S. Census Bureau Proposed Information Collection; Comment Request; Current Population Surveys (CPS)--Housing Vacancy Survey (HVS) AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY: The Department of Commerce, as part of its continuing [[Page 3611
Molecular characterization of the canine mitochondrial DNA control region for forensic applications.
Eichmann, Cordula; Parson, Walther
2007-09-01
The canine mitochondrial DNA (mtDNA) control region of 133 dogs living in the area around Innsbruck, Austria was sequenced. A total of 40 polymorphic sites were observed in the first hypervariable segment and 15 in the second, which resulted in the differentiation of 40 distinct haplotypes. We observed five nucleotide positions that were highly polymorphic within different haplogroups, and they represent good candidates for mtDNA screening. We found five point heteroplasmic positions; all located in HVS-I and a polythymine region in HVS-II, the latter often being associated with length heteroplasmy. In contrast to human mtDNA, the canine control region contains a hypervariable 10 nucleotide repeat region, which is located between the two hypervariable regions. In our population sample, we observed eight different repeat types, which we characterized by direct sequencing and fragment length analysis. The discrimination power of the canine mtDNA control region was 0.93, not taking the polymorphic repeat region into consideration.
Eichmann, Cordula; Parson, Walther
2008-09-01
The traditional protocol for forensic mitochondrial DNA (mtDNA) analyses involves the amplification and sequencing of the two hypervariable segments HVS-I and HVS-II of the mtDNA control region. The primers usually span fragment sizes of 300-400 bp each region, which may result in weak or failed amplification in highly degraded samples. Here we introduce an improved and more stable approach using shortened amplicons in the fragment range between 144 and 237 bp. Ten such amplicons were required to produce overlapping fragments that cover the entire human mtDNA control region. These were co-amplified in two multiplex polymerase chain reactions and sequenced with the individual amplification primers. The primers were carefully selected to minimize binding on homoplasic and haplogroup-specific sites that would otherwise result in loss of amplification due to mis-priming. The multiplexes have successfully been applied to ancient and forensic samples such as bones and teeth that showed a high degree of degradation.
Dejean, Cyril; Nadjar, Agnes; Le Moine, Catherine; Bioulac, Bernard; Gross, Christian E; Boraud, Thomas
2012-05-01
It is well established that parkinsonian syndrome is associated with alterations of neuronal activity temporal pattern basal ganglia (BG). An increase in synchronized oscillations has been observed in different BG nuclei in Parkinson's disease patients as well as animal models such as 6-hydroxydopamine treated rats. We recently demonstrated that this increase in oscillatory synchronization is present during high-voltage spindles (HVS) probably underpinned by the disorganization of cortex-BG interactions. Here we investigated the time course of both oscillatory and motor alterations. For that purpose we performed daily simultaneous recordings of neuronal activity in motor cortex, striatum and substantia nigra pars reticulata (SNr), before and after 6-hydroxydopamine lesion in awake rats. After a brief non-dopamine-specific desynchronization, oscillatory activity first increased during HVS followed by progressive motor impairment and the shortening of SNr activation delay. While the oscillatory firing increase reflects dopaminergic depletion, response alteration in SNr neurons is closely related to motor symptom. Copyright © 2012 Elsevier Inc. All rights reserved.
African-American mitochondrial DNAs often match mtDNAs found in multiple African ethnic groups
Ely, Bert; Wilson, Jamie Lee; Jackson, Fatimah; Jackson, Bruce A
2006-01-01
Background Mitochondrial DNA (mtDNA) haplotypes have become popular tools for tracing maternal ancestry, and several companies offer this service to the general public. Numerous studies have demonstrated that human mtDNA haplotypes can be used with confidence to identify the continent where the haplotype originated. Ideally, mtDNA haplotypes could also be used to identify a particular country or ethnic group from which the maternal ancestor emanated. However, the geographic distribution of mtDNA haplotypes is greatly influenced by the movement of both individuals and population groups. Consequently, common mtDNA haplotypes are shared among multiple ethnic groups. We have studied the distribution of mtDNA haplotypes among West African ethnic groups to determine how often mtDNA haplotypes can be used to reconnect Americans of African descent to a country or ethnic group of a maternal African ancestor. The nucleotide sequence of the mtDNA hypervariable segment I (HVS-I) usually provides sufficient information to assign a particular mtDNA to the proper haplogroup, and it contains most of the variation that is available to distinguish a particular mtDNA haplotype from closely related haplotypes. In this study, samples of general African-American and specific Gullah/Geechee HVS-I haplotypes were compared with two databases of HVS-I haplotypes from sub-Saharan Africa, and the incidence of perfect matches recorded for each sample. Results When two independent African-American samples were analyzed, more than half of the sampled HVS-I mtDNA haplotypes exactly matched common haplotypes that were shared among multiple African ethnic groups. Another 40% did not match any sequence in the database, and fewer than 10% were an exact match to a sequence from a single African ethnic group. Differences in the regional distribution of haplotypes were observed in the African database, and the African-American haplotypes were more likely to match haplotypes found in ethnic groups from West or West Central Africa than those found in eastern or southern Africa. Fewer than 14% of the African-American mtDNA sequences matched sequences from only West Africa or only West Central Africa. Conclusion Our database of sub-Saharan mtDNA sequences includes the most common haplotypes that are shared among ethnic groups from multiple regions of Africa. These common haplotypes have been found in half of all sub-Saharan Africans. More than 60% of the remaining haplotypes differ from the common haplotypes at a single nucleotide position in the HVS-I region, and they are likely to occur at varying frequencies within sub-Saharan Africa. However, the finding that 40% of the African-American mtDNAs analyzed had no match in the database indicates that only a small fraction of the total number of African haplotypes has been identified. In addition, the finding that fewer than 10% of African-American mtDNAs matched mtDNA sequences from a single African region suggests that few African Americans might be able to trace their mtDNA lineages to a particular region of Africa, and even fewer will be able to trace their mtDNA to a single ethnic group. However, no firm conclusions should be made until a much larger database is available. It is clear, however, that when identical mtDNA haplotypes are shared among many ethnic groups from different parts of Africa, it is impossible to determine which single ethnic group was the source of a particular maternal ancestor based on the mtDNA sequence. PMID:17038170
Quality issues in blue noise halftoning
NASA Astrophysics Data System (ADS)
Yu, Qing; Parker, Kevin J.
1998-01-01
The blue noise mask (BNM) is a halftone screen that produces unstructured visually pleasing dot patterns. The BNM combines the blue-noise characteristics of error diffusion and the simplicity of ordered dither. A BNM is constructed by designing a set of interdependent binary patterns for individual gray levels. In this paper, we investigate the quality issues in blue-noise binary pattern design and mask generation as well as in application to color reproduction. Using a global filtering technique and a local 'force' process for rearranging black and white pixels, we are able to generate a series of binary patterns, all representing a certain gray level, ranging from white-noise pattern to highly structured pattern. The quality of these individual patterns are studied in terms of low-frequency structure and graininess. Typically, the low-frequency structure (LF) is identified with a measurement of the energy around dc in the spatial frequency domain, while the graininess is quantified by a measurement of the average minimum distance (AMD) between minority dots as well as the kurtosis of the local kurtosis distribution (KLK) for minority pixels of the binary pattern. A set of partial BNMs are generated by using the different patterns as unique starting 'seeds.' In this way, we are able to study the quality of binary patterns over a range of gray levels. We observe that the optimality of a binary pattern for mask generation is related to its own quality mertirc values as well as the transition smoothness of those quality metric values over neighboring levels. Several schemes have been developed to apply blue-noise halftoning to color reproduction. Different schemes generate halftone patterns with different textures. In a previous paper, a human visual system (HVS) model was used to study the color halftone quality in terms of luminance and chrominance error in CIELAB color space. In this paper, a new series of psycho-visual experiments address the 'preferred' color rendering among four different blue noise halftoning schemes. The experimental results will be interpreted with respect to the proposed halftone quality metrics.
Video quality assessment based on correlation between spatiotemporal motion energies
NASA Astrophysics Data System (ADS)
Yan, Peng; Mou, Xuanqin
2016-09-01
Video quality assessment (VQA) has been a hot research topic because of rapid increase of huge demand of video communications. From the earliest PSNR metric to advanced models that are perceptual aware, researchers have made great progress in this field by introducing properties of human vision system (HVS) into VQA model design. Among various algorithms that model the property of HVS perceiving motion, the spatiotemporal energy model has been validated to be high consistent with psychophysical experiments. In this paper, we take the spatiotemporal energy model into VQA model design by the following steps. 1) According to the pristine spatiotemporal energy model proposed by Adelson et al, we apply the linear filters, which are oriented in space-time and tuned in spatial frequency, to filter the reference and test videos respectively. The outputs of quadrature pairs of above filters are then squared and summed to give two measures of motion energy, which are named rightward and leftward energy responses, respectively. 2) Based on the pristine model, we calculate summation of the rightward and leftward energy responses as spatiotemporal features to represent perceptual quality information for videos, named total spatiotemporal motion energy maps. 3) The proposed FR-VQA model, named STME, is calculated with statistics based on the pixel-wise correlation between the total spatiotemporal motion energy maps of the reference and distorted videos. The STME model was validated on the LIVE VQA Database by comparing with existing FR-VQA models. Experimental results show that STME performs with excellent prediction accuracy and stays in state-of-the-art VQA models.
Martin, Amy C; Thornton, J Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X
2004-10-01
Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluorescent protein (GFP) in Arf(+/GFP) heterozygous knock-in mouse eyes. Abnormalities in Arf(-/-) mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf(-/-) mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Arf(-/-) mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV.
Martin, Amy C.; Thornton, J. Derek; Liu, Jiewiu; Wang, XiaoFei; Zuo, Jian; Jablonski, Monica M.; Chaum, Edward; Zindy, Frederique; Skapek, Stephen X.
2006-01-01
Purpose Persistent hyperplastic primary vitreous (PHPV) is an idiopathic developmental eye disease associated with failed involution of the hyaloid vasculature. The present work addressed the pathogenesis of PHPV in a mouse model that replicates many aspects of the human disease. Methods Ophthalmoscopic and histologic analyses documented pathologic processes in eyes of mice lacking the Arf gene compared with Ink4a-deficient and wild-type control animals. Immunohistochemical staining, in situ hybridization, and RT-PCR demonstrated the expression of relevant gene products. Arf gene expression was determined by in situ hybridization using wholemounts of wild-type mouse eyes and by immunofluorescence staining for green fluores-cent protein (GFP) in Arf+/GFP heterozygous knock-in mouse eyes. Results Abnormalities in Arf−/− mice mimicked those found in patients with severe PHPV. The mice had microphthalmia; fibrovascular, retrolental tissue containing retinal pigment epithelial cells and remnants of the hyaloid vascular system; posterior lens capsule destruction with lens degeneration and opacity; and severe retinal dysplasia and detachment. Eyes of mice lacking the overlapping Ink4a gene were normal. Arf was selectively expressed in perivascular cells within the vitreous of the postnatal eye. Cells composing the retrolental mass in Arf−/− mice expressed the Arf promoter. The remnant hyaloid vessels expressed Flk-1. Its ligand, vascular endothelial growth factor (Vegf), was expressed in the retrolental tissue and the adjacent dysplastic neuroretina. Conclusions Arf−/− mice have features that accurately mimic severe PHPV. In the HVS, Arf expression in perivascular cells may block their accumulation or repress Vegf expression to promote HVS involution and prevent PHPV. PMID:15452040
Bats, Primates, and the Evolutionary Origins and Diversification of Mammalian Gammaherpesviruses
Rojas-Anaya, Edith; Kolokotronis, Sergios-Orestis; Taboada, Blanca; Loza-Rubio, Elizabeth; Méndez-Ojeda, Maria L.; Osterrieder, Nikolaus
2016-01-01
ABSTRACT Gammaherpesviruses (γHVs) are generally considered host specific and to have codiverged with their hosts over millions of years. This tenet is challenged here by broad-scale phylogenetic analysis of two viral genes using the largest sample of mammalian γHVs to date, integrating for the first time bat γHV sequences available from public repositories and newly generated viral sequences from two vampire bat species (Desmodus rotundus and Diphylla ecaudata). Bat and primate viruses frequently represented deep branches within the supported phylogenies and clustered among viruses from distantly related mammalian taxa. Following evolutionary scenario testing, we determined the number of host-switching and cospeciation events. Cross-species transmissions have occurred much more frequently than previously estimated, and most of the transmissions were attributable to bats and primates. We conclude that the evolution of the Gammaherpesvirinae subfamily has been driven by both cross-species transmissions and subsequent cospeciation within specific viral lineages and that the bat and primate orders may have potentially acted as superspreaders to other mammalian taxa throughout evolutionary history. PMID:27834200
Mycobacteria and allograft heart valve banking: an international survey.
Warwick, R M; Magee, J G; Leeming, J P; Graham, J C; Hannan, M M; Chadwick, M; Crook, D W; Yearsley, C P; Rayner, A; Parker, R
2008-03-01
Since the 1970s many tissue banks have been testing allograft heart valves (HVs) for Mycobacterium tuberculosis (MTB). Donor selection for low risk of tuberculosis (TB) was introduced in the 1980s and appears to have reduced the risk of TB transmission. Regulatory guidance does not specify testing for TB, but does exclude donors with a recent history of TB. This survey of HV international bank practices revealed variations in donor selection, testing and processing of valves. Participant banks (from Europe and the USA) reported that over a period of 15 years, HV tissues from 38,413 donors were banked and 32,289 donors were tested for TB, none being positive. HV-associated tissue from 27,840 donors was stained and underwent microscopy; none of these were positive for acid-fast bacilli (AFB). Non-tuberculosis mycobacteria (NTBM) were detected by culture on 24 HVs. It is recommended that HV banks employ donor selection to exclude donors at risk of TB, to culture material for mycobacteria, and to investigate potential sources when clusters of NTBM are found to facilitate corrective and preventative actions.
Pevernagie, Dirk; Mariman, An; Vandenbussche, Nele; Tobback, Els; Overeem, Sebastiaan; Delesie, Liesbeth; Janssen, Hennie; Vogelaers, Dirk
2012-12-01
Central sleep apnoea (CSA) is a disorder characterised by repetitive episodes of decreased ventilation due to complete or partial reduction in the central neural outflow to the respiratory muscles. Hyperventilation plays a prime role in the pathogenesis of CSA. Chronic heart failure and dwelling at high altitude are classical conditions in which CSA is induced by hyperventilation. Hyperventilation syndrome (HVS) is a prevalent behavioural condition in which minute ventilation exceeds metabolic demands, resulting in haemodynamic and chemical changes that produce characteristic dysphoric symptoms. HVS is frequently caused by anxiety disorders and panic attacks. Until now, medical literature has focussed primarily on daytime symptoms of behavioural hyperventilation. It is currently unknown how this condition may affect sleep. Three cases are reported in which behavioural hyperventilation was associated with occurrence of significant central sleep apnoea, which was not present during normal tidal breathing in steady sleep. Therefore, behavioural hyperventilation should be added to the list of known clinical conditions associated with CSA. Copyright © 2012 Elsevier B.V. All rights reserved.
Phase-based motion magnification video for monitoring of vital signals using the Hermite transform
NASA Astrophysics Data System (ADS)
Brieva, Jorge; Moya-Albor, Ernesto
2017-11-01
In this paper we present a new Eulerian phase-based motion magnification technique using the Hermite Transform (HT) decomposition that is inspired in the Human Vision System (HVS). We test our method in one sequence of the breathing of a newborn baby and on a video sequence that shows the heartbeat on the wrist. We detect and magnify the heart pulse applying our technique. Our motion magnification approach is compared to the Laplacian phase based approach by means of quantitative metrics (based on the RMS error and the Fourier transform) to measure the quality of both reconstruction and magnification. In addition a noise robustness analysis is performed for the two methods.
Tomaszewski, Elizabeth K.; Kaleta, Erhard F.; Phalen, David N.
2003-01-01
Fragments of 419 bp of the UL16 open reading frame from 73 psittacid herpesviruses (PsHVs) from the United States and Europe were sequenced. All viruses caused Pacheco's disease, and serotypes of the European isolates were known. A phylogenetic tree derived from these sequences demonstrated that the PsHVs that cause Pacheco's disease comprised four major genotypes, with each genotype including between two and four variants. With the exception of two viruses, the serotypes of the virus isolates could be predicted by the genotypes. Genotypes 1 and 4 corresponded to serotype 1 isolates, genotype 2 corresponded to serotype 2 isolates, and genotype 3 corresponded to serotype 3 isolates. The single serotype 4 virus mapped to genotype 4. DNA from a virus with a unique serotype could not be amplified with primers that amplified DNA from all other PsHVs, and its classification remains unknown. Viruses representing all four genotypes were found in both the United States and Europe, and it was therefore predicted that serotypes 1, 2, and 3 were present in the United States. Serotype 4 was represented by a single European isolate that could not be genetically distinguished from serotype 1 viruses; therefore, the presence of serotype 4 in the United States could not be predicted. Viruses of genotype 4 were found to be the most commonly associated with Pacheco's disease in macaws and conures and were least likely to be isolated in chicken embryo fibroblasts in the United States. All four genotypes caused deaths in Amazon parrots, but genotype 4 was associated with Pacheco's disease only in Amazons in Europe. Genotypes 2, 3, and 4, but not 1, were found in African grey parrots. Although parrots from the Pacific distribution represent a relatively small percentage of the total number of birds with Pacheco's disease, all four genotypes were found to cause disease in these species. PMID:14512573
Gajendragadkar, Parag R.; Hubsch, Annette; Mäki-Petäjä, Kaisa M.; Serg, Martin; Wilkinson, Ian B.; Cheriyan, Joseph
2014-01-01
Aims The mechanisms by which a ‘Mediterranean diet’ reduces cardiovascular disease (CVD) burden remain poorly understood. Lycopene is a potent antioxidant found in such diets with evidence suggesting beneficial effects. We wished to investigate the effects of lycopene on the vasculature in CVD patients and separately, in healthy volunteers (HV). Methods and Results We randomised 36 statin treated CVD patients and 36 healthy volunteers in a 2∶1 treatment allocation ratio to either 7 mg lycopene or placebo daily for 2 months in a double-blind trial. Forearm responses to intra-arterial infusions of acetylcholine (endothelium-dependent vasodilatation; EDV), sodium nitroprusside (endothelium-independent vasodilatation; EIDV), and NG-monomethyl-L-arginine (basal nitric oxide (NO) synthase activity) were measured using venous plethysmography. A range of vascular and biochemical secondary endpoints were also explored. EDV in CVD patients post-lycopene improved by 53% (95% CI: +9% to +93%, P = 0.03 vs. placebo) without changes to EIDV, or basal NO responses. HVs did not show changes in EDV after lycopene treatment. Blood pressure, arterial stiffness, lipids and hsCRP levels were unchanged for lycopene vs. placebo treatment groups in the CVD arm as well as the HV arm. At baseline, CVD patients had impaired EDV compared with HV (30% lower; 95% CI: −45% to −10%, P = 0.008), despite lower LDL cholesterol (1.2 mmol/L lower, 95% CI: −1.6 to −0.9 mmol/L, P<0.001). Post-therapy EDV responses for lycopene-treated CVD patients were similar to HVs at baseline (2% lower, 95% CI: −30% to +30%, P = 0.85), also suggesting lycopene improved endothelial function. Conclusions Lycopene supplementation improves endothelial function in CVD patients on optimal secondary prevention, but not in HVs. Trial Registration ClinicalTrials.gov NCT01100385 PMID:24911964
Abdu, Lena; Stenner, Karen; Vydelingum, Vasso
2016-09-01
The fact that health inequalities disproportionately affect the minority ethnic population is not new and projections are that the minority ethnic population will continue to increase. The importance of early intervention and the key role that health visitors can play in attempting to reduce health inequalities is well documented as is the requirement for health providers to establish culturally sensitive services. To date, much of the research has focused on the perspectives of healthcare professionals caring for minority ethnic clients in hospital-based settings and little is known about the perspectives of minority ethnic clients regarding the health visiting service (HVS). The aim of this study was to explore the perspectives of South Asians regarding their experiences with the HVS. The study was conducted in a small town in the South of England between March and June 2013. A qualitative study using a grounded theory approach was used to capture the perspectives of this group regarding their interactions with the HVS. The sample consisted of 15 participants and data were collected through audio-recorded semi-structured interviews and analysed using constant comparative approach. Three key categories were identified: 'understanding the health visitor's role', 'sensitivity of services' and 'the significance of family'. While clients valued one-to-one support from health visitors, there was some evidence of poor communication and ethnocentric tendencies within the service. It was found that South Asian clients distinguish between health and parenting advice, being more likely to accept health advice from their health visitor and more likely to accept parenting advice from their family. The findings, although limited in their generalisability, offer important insights into how South Asians perceive the service and will equip health visitors with a better understanding of how best to improve the experience of South Asian clients accessing the health visiting. © 2015 John Wiley & Sons Ltd.
Watermarking spot colors in packaging
NASA Astrophysics Data System (ADS)
Reed, Alastair; Filler, TomáÅ.¡; Falkenstern, Kristyn; Bai, Yang
2015-03-01
In January 2014, Digimarc announced Digimarc® Barcode for the packaging industry to improve the check-out efficiency and customer experience for retailers. Digimarc Barcode is a machine readable code that carries the same information as a traditional Universal Product Code (UPC) and is introduced by adding a robust digital watermark to the package design. It is imperceptible to the human eye but can be read by a modern barcode scanner at the Point of Sale (POS) station. Compared to a traditional linear barcode, Digimarc Barcode covers the whole package with minimal impact on the graphic design. This significantly improves the Items per Minute (IPM) metric, which retailers use to track the checkout efficiency since it closely relates to their profitability. Increasing IPM by a few percent could lead to potential savings of millions of dollars for retailers, giving them a strong incentive to add the Digimarc Barcode to their packages. Testing performed by Digimarc showed increases in IPM of at least 33% using the Digimarc Barcode, compared to using a traditional barcode. A method of watermarking print ready image data used in the commercial packaging industry is described. A significant proportion of packages are printed using spot colors, therefore spot colors needs to be supported by an embedder for Digimarc Barcode. Digimarc Barcode supports the PANTONE spot color system, which is commonly used in the packaging industry. The Digimarc Barcode embedder allows a user to insert the UPC code in an image while minimizing perceptibility to the Human Visual System (HVS). The Digimarc Barcode is inserted in the printing ink domain, using an Adobe Photoshop plug-in as the last step before printing. Since Photoshop is an industry standard widely used by pre-press shops in the packaging industry, a Digimarc Barcode can be easily inserted and proofed.
Di Stefano, Michele; Miceli, Emanuela; Tana, Paola; Mengoli, Caterina; Bergonzi, Manuela; Pagani, Elisabetta; Corazza, Gino Roberto
2014-10-01
Little information is available on the mechanisms responsible for dyspeptic symptoms in postprandial distress syndrome (PDS), characterized by the presence of prevalently meal-related early satiation and fullness, and the epigastric pain syndrome (EPS), characterized by the prominent symptom of epigastric pain, generally not meal related. In a group of PDS patients, the presence of hypersensitivity to gastric distension in both fasting and postprandial phases was described as the main pathophysiological mechanism; on the contrary, we have no information on the pathophysiology of EPS. Sixty Helicobacter pylori (HP)-negative, irritable bowel syndrome (IBS)-negative, and gastroesophageal reflux disease (GERD)-negative patients with functional dyspepsia according to Rome III criteria underwent symptom, anxiety, depression, and somatization evaluation, gastric barostat test, and gastric emptying time evaluation for solids. Fifteen age- and sex-matched healthy volunteers (HVs) were also enrolled as a control group. In PDS patients, the prevalence of both fasting and postprandial hypersensitivity was higher than in EPS patients, and the extent of postprandial reduction of discomfort threshold was significantly correlated with symptom severity. In EPS patients, gastric volume at fasting discomfort threshold and fasting compliance were significantly lower than in PDS patients. Gastric emptying time and gastric accommodation were similar between the two dyspeptic groups. Dyspeptic patients showed a higher prevalence of psychiatric disorders than HVs, but the prevalence was similar between PDS and EPS patients. Fasting and postprandial hypersensitivity characterize PDS patients and a reduction of gastric compliance is present in EPS patients. However, the pathophysiology of EPS appears more complex than PDS and further studies are needed to analyze central processing and integration of afferent pathways in order to clarify the role of the central nervous system in this condition.
This SOP describes the method for collecting a floor dust sample from carpet. Dust samples will be collected in the room that the child uses most at home and/or at day care using a High Volume Small Surface Sampler (HVS3). In addition, participants will also be asked to donate a ...
Stauffer, John A; Onkendi, Edwin O; Wallace, Michael B; Raimondo, Massimo; Woodward, Timothy A; Lukens, Frank J; Asbun, Horacio J
2017-09-01
In the past two decades, pancreas surgery (PS) has undergone significant advances in operative techniques and with a focus on multidisciplinary high-volume practices. A review of patients undergoing PS from 3/1995-2/2015 was conducted; dividing patients into group A (1995-2005) and group B (2005-2015) for a detailed comparison. Effect of surgeon volume in group B was determined. A total of 1001 patients underwent PS (group A: 259; group B: 742). The mean age was 62.7 years and 52.8% were female. Group B patients were associated with a higher rate of pylorus preservation and minimally invasive resection and a lower rate of morbidity, pancreas fistula (PF), and delayed gastric emptying (DGE) than group A. High-volume surgeons (HVS) had lower operative blood loss (300 mL vs 600 mL), transfusion requirements, PF (14% vs 20%), DGE, surgical site infections, reoperations, and major morbidity rate (15.5 vs 39%) than low-volume surgeons. This study demonstrates improved patient outcomes and hospital resource utilization over the past 20 years. Concentration of PS to HVS results in superior results. Copyright © 2017 Elsevier Inc. All rights reserved.
Impaired brainstem and thalamic high-frequency oscillatory EEG activity in migraine between attacks.
Porcaro, Camillo; Di Lorenzo, Giorgio; Seri, Stefano; Pierelli, Francesco; Tecchio, Franca; Coppola, Gianluca
2017-09-01
Introduction We investigated whether interictal thalamic dysfunction in migraine without aura (MO) patients is a primary determinant or the expression of its functional disconnection from proximal or distal areas along the somatosensory pathway. Methods Twenty MO patients and twenty healthy volunteers (HVs) underwent an electroencephalographic (EEG) recording during electrical stimulation of the median nerve at the wrist. We used the functional source separation algorithm to extract four functionally constrained nodes (brainstem, thalamus, primary sensory radial, and primary sensory motor tangential parietal sources) along the somatosensory pathway. Two digital filters (1-400 Hz and 450-750 Hz) were applied in order to extract low- (LFO) and high- frequency (HFO) oscillatory activity from the broadband signal. Results Compared to HVs, patients presented significantly lower brainstem (BS) and thalamic (Th) HFO activation bilaterally. No difference between the two cortical HFO as well as in LFO peak activations between the two groups was seen. The age of onset of the headache was positively correlated with HFO power in the right brainstem and thalamus. Conclusions This study provides evidence for complex dysfunction of brainstem and thalamocortical networks under the control of genetic factors that might act by modulating the severity of migraine phenotype.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelada, O; Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg; Decker, R
2014-06-15
Purpose: Tumor hypoxia is correlated with treatment failure. To date, there are no published studies investigating hypoxia in non-small cell lung cancer (NSCLC) patients undergoing SBRT. We aim to use 18F-fluoromisonidazole (18F-FMISO) positron emission tomography (PET) imaging to non-invasively quantify the tumor hypoxic volume (HV), to elucidate potential roles of reoxygenation and tumor vascular response at high doses, and to identify an optimal prognostic imaging time-point. Methods: SBRT-eligible patients with NSCLC tumors >1cm were prospectively enrolled in an IRB-approved study. Computed Tomography and dynamic PET images (0–120min, 150–180min, and 210–240min post-injection) were acquired using a Siemens BiographmCT PET/CT scanner. 18F-FMISOmore » PET was performed on a single patient at 3 different time points around a single SBRT delivery of 18 Gy and HVs were compared using a tumor-to-blood ratio (TBR)>1.2 and rate of influx (Ki)>0.0015 (Patlak). Results: Results from our first patient showed substantial temporal changes in HV following SBRT. Using a TBR threshold >1.2 and summed images 210–240min, the HVs were 19%, 31% and 13% of total tumor volume on day 0, 2 (48 hours post-SBRT), and 4 (96 hours post-SBRT). The absolute volume of hypoxia increased by nearly a factor of 2 after 18 Gy and then decreased almost to baseline 96 hours later. Selected imaging timepoints resulted in temporal changes in HV quantification obtained with TBR. Ki, calculated using 4-hour dynamic data, evaluated HVs as 22%, 75% and 21%, respectively. Conclusions: ith the results of only one patient, this novel pilot study highlights the potential benefit of 18F-FMISO PET imaging as results indicate substantial temporal changes in tumor HV post-SBRT. Analysis suggests that TBR is not a robust parameter for accurate HV quantification and heavily influenced by imaging timepoint selection. Kinetic modeling parameters are more sensitive and may aid in future treatment individualization based on patient-specific biological information.« less
Synthesis and Mass Spectrometric Characterization of Organic Nitrates
NASA Astrophysics Data System (ADS)
Grünert, A.; Woidich, S.; Ballschmiter, K.
2003-04-01
Organic nitrates, as trace constituents in urban air, can be analyzed by adsorptive low volume sampling (LVS) as well as by adsorptive high volume sampling (HVS). Air samples ranging from 25 L to 100 L for the LVS and 100 m3 to 500 m3 for the (HVS) were collected, respectively. Analysis is performed by thermodesorption (LVS) or solvent elution combined with group separation (HVS) using normal-phase HPLC and high resolution capillary gas chromatography with electron capture detection (HRGC-ECD) and mass selective detection (HRGC-MSD). For identification and quantification available reference compounds are required for both methods (1;2). Following numbers of congeners of organic nitrate have been synthesized: 77 monoalkyl nitrates (C1-C16), 43 dialkyl nitrates (C2-C10), 37 hydroxy alkyl nitrates (C2-C8) and 41 carbonyl alkyl nitrates (C3-C12). Alkanes, alkenes, alcohols, ketones and halocarbons have been used as precursors. Characterisation of the reference compounds by retention-data and mass-spectra was performed by high resolution capillary gas chromatography with mass selective detection in the EI- and the NCI (CH4) mode (1-3). EI-ionization leads to the dominating indicator ion NO2+ for organic nitrates with m/z = 46 u. The characteristic fragments with NCI (CH4) show ions at m/z = 46 u and m/z = 62 u, corresponding to NO2- and NO3-. The use of flame ionisation detection (HRGC-FID) and the principle of the molar response for carbon allows the quantitation of reference solutions as the final tool for the determination of the levels and patterns of organic nitrates in urban air samples. (1) J. Kastler: "Analytik, Massenspektrometrie und Vorkommen multifunktioneller Alkylnitrate in belasteter und unbelasteter Atmosphäre" Dr.rer.nat.-Thesis, University of Ulm (1999) (2) G. Werner, J. Kastler, R. Looser, K. Ballschmiter: "Organic Nitrates of Isoprenes as Atmospheric Trace Compounds" Angew. Chem. Int. Ed. (1999) 38(11): 1634-1637 (3) S.Woidich, O. Froscheis, O. Luxenhofer, K. Ballschmiter: "EI- and NCI-mass spectrometry of aryl-alkyl nitrates and their occurrence in urban air" Fresenius J Anal Chem (1999) 364: 91-99
2011-05-01
genome was determined and compared to simian and human herpesvirus genomes representing alpha-herpesvi- ruses, beta- herpesviruses and gamma-1 and...of JMRV Genome with Select Simian and Human Herpesvirus Genomes Showing Percent Nucleotide Sequence Identity Virus JMRV RRV KSHV HVS RhLCV EBV RhCMV...2 - Introduction Particular viruses, especially gama- herpesviruses , may act as a trigger of multiple sclerosis (MS) (Levin et
Life Cycle Assessment for Chemical Agent Resistant Coating.
1996-09-01
994) document to develop HVs from 1 to 2.5. The final equivalency factor for a chemical was based on the formula: Equivalency Factor = (toxicity HV...applicable to the development of processes/procedures and their implementation, likely would fit better with a true LCA- based design exercise for a product...Johnny Springer, Jr., National Risk Management Research Laboratory, Office of Research and Development , U.S. Environmental Protection Agency
The complex and diversified mitochondrial gene pool of Berber populations.
Coudray, C; Olivieri, A; Achilli, A; Pala, M; Melhaoui, M; Cherkaoui, M; El-Chennawi, F; Kossmann, M; Torroni, A; Dugoujon, J M
2009-03-01
The mitochondrial DNA variation of 295 Berber-speakers from Morocco (Asni, Bouhria and Figuig) and the Egyptian oasis of Siwa was evaluated by sequencing a portion of the control region (including HVS-I and part of HVS-II) and surveying haplogroup-specific coding region markers. Our findings show that the Berber mitochondrial pool is characterized by an overall high frequency of Western Eurasian haplogroups, a somehow lower frequency of sub-Saharan L lineages, and a significant (but differential) presence of North African haplogroups U6 and M1, thus occupying an intermediate position between European and sub-Saharan populations in PCA analysis. A clear and significant genetic differentiation between the Berbers from Maghreb and Egyptian Berbers was also observed. The first are related to European populations as shown by haplogroup H1 and V frequencies, whereas the latter share more affinities with East African and Nile Valley populations as indicated by the high frequency of M1 and the presence of L0a1, L3i, L4*, and L4b2 lineages. Moreover, haplogroup U6 was not observed in Siwa. We conclude that the origins and maternal diversity of Berber populations are old and complex, and these communities bear genetic characteristics resulting from various events of gene flow with surrounding and migrating populations.
Medveczky, Maria M; Sherwood, Tracy A; Klein, Thomas W; Friedman, Herman; Medveczky, Peter G
2004-09-15
The major psychoactive cannabinoid compound of marijuana, delta-9 tetrahydrocannabinol (THC), has been shown to modulate immune responses and lymphocyte function. After primary infection the viral DNA genome of gamma herpesviruses persists in lymphoid cell nuclei in a latent episomal circular form. In response to extracellular signals, the latent virus can be activated, which leads to production of infectious virus progeny. Therefore, we evaluated the potential effects of THC on gamma herpesvirus replication. Tissue cultures infected with various gamma herpesviruses were cultured in the presence of increasing concentrations of THC and the amount of viral DNA or infectious virus yield was compared to those of control cultures. The effect of THC on Kaposi's Sarcoma Associated Herpesvirus (KSHV) and Epstein-Barr virus (EBV) replication was measured by the Gardella method and replication of herpesvirus saimiri (HVS) of monkeys, murine gamma herpesvirus 68 (MHV 68), and herpes simplex type 1 (HSV-1) was measured by yield reduction assays. Inhibition of the immediate early ORF 50 gene promoter activity was measured by the dual luciferase method. Micromolar concentrations of THC inhibit KSHV and EBV reactivation in virus infected/immortalized B cells. THC also strongly inhibits lytic replication of MHV 68 and HVS in vitro. Importantly, concentrations of THC that inhibit virus replication of gamma herpesviruses have no effect on cell growth or HSV-1 replication, indicating selectivity. THC was shown to selectively inhibit the immediate early ORF 50 gene promoter of KSHV and MHV 68. THC specifically targets viral and/or cellular mechanisms required for replication and possibly shared by these gamma herpesviruses, and the endocannabinoid system is possibly involved in regulating gamma herpesvirus latency and lytic replication. The immediate early gene ORF 50 promoter activity was specifically inhibited by THC. These studies may also provide the foundation for the development of antiviral strategies utilizing non-psychoactive derivatives of THC.
Al-Dmour, Hayat; Al-Ani, Ahmed
2016-04-01
The present work has the goal of developing a secure medical imaging information system based on a combined steganography and cryptography technique. It attempts to securely embed patient's confidential information into his/her medical images. The proposed information security scheme conceals coded Electronic Patient Records (EPRs) into medical images in order to protect the EPRs' confidentiality without affecting the image quality and particularly the Region of Interest (ROI), which is essential for diagnosis. The secret EPR data is converted into ciphertext using private symmetric encryption method. Since the Human Visual System (HVS) is less sensitive to alterations in sharp regions compared to uniform regions, a simple edge detection method has been introduced to identify and embed in edge pixels, which will lead to an improved stego image quality. In order to increase the embedding capacity, the algorithm embeds variable number of bits (up to 3) in edge pixels based on the strength of edges. Moreover, to increase the efficiency, two message coding mechanisms have been utilized to enhance the ±1 steganography. The first one, which is based on Hamming code, is simple and fast, while the other which is known as the Syndrome Trellis Code (STC), is more sophisticated as it attempts to find a stego image that is close to the cover image through minimizing the embedding impact. The proposed steganography algorithm embeds the secret data bits into the Region of Non Interest (RONI), where due to its importance; the ROI is preserved from modifications. The experimental results demonstrate that the proposed method can embed large amount of secret data without leaving a noticeable distortion in the output image. The effectiveness of the proposed algorithm is also proven using one of the efficient steganalysis techniques. The proposed medical imaging information system proved to be capable of concealing EPR data and producing imperceptible stego images with minimal embedding distortions compared to other existing methods. In order to refrain from introducing any modifications to the ROI, the proposed system only utilizes the Region of Non Interest (RONI) in embedding the EPR data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The Hmong Diaspora: preserved South-East Asian genetic ancestry in French Guianese Asians.
Brucato, Nicolas; Mazières, Stéphane; Guitard, Evelyne; Giscard, Pierre-Henri; Bois, Etienne; Larrouy, Georges; Dugoujon, Jean-Michel
2012-01-01
The Hmong Diaspora is one of the widest modern human migrations. Mainly localised in South-East Asia, the United States of America, and metropolitan France, a small community has also settled the Amazonian forest of French Guiana. We have biologically analysed 62 individuals of this unique Guianese population through three complementary genetic markers: mitochondrial DNA (HVS-I/II and coding region SNPs), Y-chromosome (SNPs and STRs), and the Gm allotypic system. All genetic systems showed a high conservation of the Asian gene pool (Asian ancestry: mtDNA=100.0%; NRY=99.1%; Gm=96.6%), without a trace of founder effect. When compared across various Asian populations, the highest correlations were observed with Hmong-Mien groups still living in South-East Asia (Fst<0.05; P-value<0.05). Despite a long history punctuated by exodus, the French Guianese Hmong have maintained their original genetic diversity. Copyright © 2012 Académie des sciences. Published by Elsevier SAS. All rights reserved.
Clinically significant personality traits in individuals at high risk of developing psychosis.
Sevilla-Llewellyn-Jones, Julia; Camino, Gustavo; Russo, Debra A; Painter, Michelle; Montejo, Angel L; Ochoa, Susana; Jones, Peter B; Perez, Jesus
2018-03-01
It is still unclear to what extent personality may influence the development of psychosis. We aimed to explore significant personality traits in individuals at high-risk (HR) for psychosis. Personalities of forty HR individuals and a matched sample of 40 healthy volunteers (HVs) were evaluated with the Millon Multiaxial Inventory (MCMI-III). They were also assessed with the Positive and Negative Symptoms Scale (PANSS), Beck Depression and Anxiety Inventories (BDI-II and BAI), Global Assessment of Functioning (GAF) and Mini-International Neuropsychiatric Interview (MINI 6.0.0). Fisher's exact test was employed to compare frequency of traits. Mann-Whitney U test and logistic regression were used to establish relationships between traits and symptoms, and the effect of age, sex and symptoms on such traits. Most HR individuals (97.5%) had at least one significant trait; 75% had personality disorders, mainly depressive, borderline or schizotypal. Only histrionic and narcissistic traits were more prevalent in HVs. Negative symptoms were related to schizoid and paranoid traits. Depression was more severe with borderline traits. Most HR individuals (67.6%) had more than one DSM-IV Axis I diagnosis, mainly depressive/anxiety disorders. Transition rate was low (5%). Certain personality profiles may not be markers for conversions to psychosis but contribute to high morbidity in HR individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
Pectinate ligament dysplasia in the Border Collie, Hungarian Vizsla and Golden Retriever.
Oliver, James A C; Ekiri, Abel B; Mellersh, Cathryn S
2017-03-18
Pectinate ligament dysplasia (PLD) is significantly associated with primary closed angle glaucoma (PCAG) in several dog breeds. Gonioscopy screening for PLD is advised in breeds in which PLD and PCAG are particularly prevalent in order that affected dogs may be eliminated from the breeding population. The Border Collie (BC), Hungarian Vizsla (HV) and Golden Retriever (GR) breeds are currently under investigation for PLD by the British Veterinary Association/Kennel Club/International Sheep Dog Society (BVA/KC/ISDS) Eye Scheme. The authors aimed to determine the prevalence of PLD in UK populations of BC, HV and GR and to investigate possible associations between the degree of PLD and age and sex. Gonioscopy was performed in 102 BCs, 112 HVs and 230 GRs and the percentage of iridocorneal angle affected by PLD was estimated and classified as unaffected (0 per cent), mildly affected (<20 per cent), moderately affected (20-90 per cent) or severely affected (>90 per cent). Eleven of 102 (13.8 per cent) BCs, 16/112 (14.3 per cent) HVs and 60/230 (26.1 per cent) GRs were moderately or severely affected by PLD. The prevalence of PLD was significantly higher in GR than both BC and HV. There was a significant positive correlation between PLD and age in the HV and GR but not in the BC. There was no association between PLD and sex in any breed. British Veterinary Association.
Dependence of Noise in Magnetic Tunnel Junctions Sensors on Annealing Field and Temperature
2008-03-07
and can be characterized by Hooge’s formula,11,12 Sf = HVs 2 NAf , where H is the material-specific Hooge parameter , A is the junction area, and...noise floor at low frequency in the future. Figure 5 shows the fitting of the noise spectra, which provides values for the Hooge parameter H for the...environment. © 2008 American Institute of Physics. DOI: 10.1063/1.2837659 I. INTRODUCTION Sensor noise is a crucial parameter in low-field applica- tions
2008-02-01
tu- mor cells. In this regard, herpesvirus samiri (HVS) was de- monstrated to be naturally selectively oncolytic for the pancreatic cancer line PANC-1...the hexon virus. Therefore, Ad can provide a versatile platform for selective binding of AuNPs, resulting in a multifunctional agent capable of...utility remained unaffected. Therefore, Ad can provide a versatile platform for selective binding of nanoparticles, resulting in a multifunctional agent
2007-08-01
selective or are genetically modified to be selective for replication competence in tu- mor cells. In this regard, herpesvirus samiri (HVS) was de...logy 76, 4559-4566 Ring CJ (2002) Cytolytic viruses as potential anti -cancer agents . The Journal of General Virology 83, 491-502 Riviere C, Danos O...precursors for tumor stroma and targeted-delivery vehicles for anti - cancer agents . Journal of the National Cancer Institute 96, 1593-1603 Takanami
Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning
2015-01-01
AIM: To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. METHODS: Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. RESULTS: Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. CONCLUSION: Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice. PMID:26140004
Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning
2015-06-28
To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P < 0.001). 4SLHBT showed excellent diagnostic concordance with standard LHBT (97%-100%, Kappa 0.815-0.942) with high sensitivity (90%-100%) and specificity (100%) at all three lactose doses in both groups. Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.
Phylogenetic Network for European mtDNA
Finnilä, Saara; Lehtonen, Mervi S.; Majamaa, Kari
2001-01-01
The sequence in the first hypervariable segment (HVS-I) of the control region has been used as a source of evolutionary information in most phylogenetic analyses of mtDNA. Population genetic inference would benefit from a better understanding of the variation in the mtDNA coding region, but, thus far, complete mtDNA sequences have been rare. We determined the nucleotide sequence in the coding region of mtDNA from 121 Finns, by conformation-sensitive gel electrophoresis and subsequent sequencing and by direct sequencing of the D loop. Furthermore, 71 sequences from our previous reports were included, so that the samples represented all the mtDNA haplogroups present in the Finnish population. We found a total of 297 variable sites in the coding region, which allowed the compilation of unambiguous phylogenetic networks. The D loop harbored 104 variable sites, and, in most cases, these could be localized within the coding-region networks, without discrepancies. Interestingly, many homoplasies were detected in the coding region. Nucleotide variation in the rRNA and tRNA genes was 6%, and that in the third nucleotide positions of structural genes amounted to 22% of that in the HVS-I. The complete networks enabled the relationships between the mtDNA haplogroups to be analyzed. Phylogenetic networks based on the entire coding-region sequence in mtDNA provide a rich source for further population genetic studies, and complete sequences make it easier to differentiate between disease-causing mutations and rare polymorphisms. PMID:11349229
Zaidi, K U; Shah, F; Parmar, R; Thawani, V
2018-06-01
Candida albicans is the most prevalent fungal pathogen in humans. It is the causative agent and most associated with serious fungal infection, accounting for more than 90% of cases. It is a most common cause of deep mycoses and vulvovaginal candidiasis. In the present study we found that methanolic extract of O. sanctum in combination of fluconazole shows higher zone of inhibition and lesser MIC values as compared to methanolic extract of leaves of O. sanctum or fluconazole when used alone. Synergistic antimicrobial activity was found when methanolic extract of leaves of O. sanctum was used in combination with fluconazole against C. albicans azole resistance strains isolated from catheter tip (CT) and high vaginal swab (HVS) (FIC≤0.5). Partial synergistic activity was observed against urine (U). Methanolic extract of stem of O. sanctum in combination with fluconazole gave indifferent antifungal results (FIC=1.0-4.0). Benzene extract of the leaf and stem of O. sanctum in combination with fluconazole showed indifferent antifungal results (FIC=1.0-4.0). Aqueous extract of leaves of O. sanctum in combination with fluconazole showed partial synergistic antimicrobial activity against catheter tip (CT) and high vaginal swab (HVS) and urine (U) (FIC=0.5-1.0). In the present study we evaluate the synergism of C. albicans against azole resistant clinical isolates. This study indicates clear evidence supporting the traditional use of O. sanctum in treating Candida infectious diseases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Negative urgency and reward/punishment sensitivity in intermittent explosive disorder.
Puhalla, Alexander A; Ammerman, Brooke A; Uyeji, Lauren L; Berman, Mitchell E; McCloskey, Michael S
2016-09-01
Intermittent explosive disorder (IED) is the sole psychiatric diagnosis in which affective aggression is the cardinal symptom. Previous research has been equivocal with regard to the relationship between IED and impulsivity. This inconsistency may reflect the varied facets of impulsivity, with some aspects of impulsivity (e.g. negative urgency) as well as some overlapping, albeit distinct constructs (e.g. reward and punishment sensitivity) yet to be studied. The present study compared individuals diagnosed with IED (n=81) with psychiatric controls (PCs; n=52) and healthy volunteers (HVs; n=58) on the impulsivity domains of negative and positive urgency, perseverance, sensation seeking, and premeditation, as well as on reward and punishment sensitivity. We hypothesized that individuals with IED would show greater negative and positive urgency, reward sensitivity, punishment sensitivity, with negative urgency independently predicting IED status. We also hypothesized that negative urgency would predict levels of anger, aggression, and aggression control among those with IED. The IED participants reported greater negative urgency than both comparison groups, and greater levels of positive urgency, reward sensitivity, and punishment sensitivity compared to HVs. Further, heightened negative urgency was the sole predictor an IED diagnosis. Within the IED group negative urgency uniquely predicted decreased aggression control and increased trait anger. Limitations included reliance on self-report measures to assess RS/PS, impulsivity, and aggression. These findings suggest that negative urgency is a key factor associated with IED and is associated with dampened control of aggression within those with IED. Copyright © 2016 Elsevier B.V. All rights reserved.
Sanada, Yukihiro; Sakuma, Yasunaru; Sasanuma, Hideki; Miki, Atsushi; Katano, Takumi; Hirata, Yuta; Okada, Noriki; Yamada, Naoya; Ihara, Yoshiyuki; Urahashi, Taizen; Sata, Naohiro; Yasuda, Yoshikazu; Mizuta, Koichi
2016-09-14
Utilizing the opened round ligament as venous grafts during liver transplantation is useful but controversial, and there are no pathological analyses of this procedure. Herein, we describe the first reported case of a pathological analysis of an opened round ligament used as a venous patch graft in a living donor liver transplantation (LDLT). A 13-year-old female patient with biliary atresia underwent LDLT using a posterior segment graft from her mother. The graft had two hepatic veins (HVs), which included the right HV (RHV; 15 mm) and the inferior RHV (IRHV; 20 mm). The graft RHV and IRHV were formed into a single orifice using the donor's opened round ligament (60 mm × 20 mm) as a patch graft during bench surgery; it was then anastomosed end-to-side with the recipient inferior vena cava. The recipient had no post-transplant complications involving the HVs, but she died of septic shock with persistent cholangitis and jaundice 86 d after LDLT. The HV anastomotic site had no stenosis or thrombus on autopsy. On pathology, there was adequate patency and continuity between the recipient's HV and the donor's opened round ligament. In addition, the stains for CD31 and CD34 on the inner membrane of the opened round ligament were positive. Hepatic venous reconstruction using the opened round ligament as a venous patch graft is effective in LDLT, as observed on pathology.
Comprehensive view of the population history of Arabia as inferred by mtDNA variation.
Černý, Viktor; Čížková, Martina; Poloni, Estella S; Al-Meeri, Ali; Mulligan, Connie J
2016-04-01
Genetic and archaeological research supports the theory that Arabia was the first region traversed by modern humans as they left Africa and dispersed throughout Eurasia. However, the role of Arabia from the initial migration out of Africa until more recent times is still unclear. We have generated 379 new hypervariable segment 1 (HVS-1) sequences from a range of geographic locations throughout Yemen. We compare these data to published HVS-1 sequences representing Arabia and neighboring regions to build a unique dataset of 186 populations and 14,290 sequences. We identify 4,563 haplotypes unevenly distributed across Arabia and neighboring regions. Arabia contains higher proportions of shared haplotypes than the regions with which it shares these haplotypes, suggesting high levels of migration through the region. Populations in Arabia show higher levels of population expansion than those in East Africa, but lower levels than the Near East, Middle East or India. Arabian populations also show very high levels of genetic variation that overlaps with variation from most other regions. We take a population genetics approach to provide a comprehensive view of the relationships of Arabian and neighboring populations. We show that Arabian populations share closest links to the Near East and North Africa, but have a more ancient origin with slower demographic growth and/or lower migration rates. Our conclusions are supported by phylogenetic studies but also suggest that recent migrations have erased signals of earlier events. © 2015 Wiley Periodicals, Inc.
Delfin, Frederick; Min-Shan Ko, Albert; Li, Mingkun; Gunnarsdóttir, Ellen D; Tabbada, Kristina A; Salvador, Jazelyn M; Calacal, Gayvelline C; Sagum, Minerva S; Datar, Francisco A; Padilla, Sabino G; De Ungria, Maria Corazon A; Stoneking, Mark
2014-01-01
The Philippines is a strategic point in the Asia-Pacific region for the study of human diversity, history and origins, as it is a cross-road for human migrations and consequently exhibits enormous ethnolinguistic diversity. Following on a previous in-depth study of Y-chromosome variation, here we provide new insights into the maternal genetic history of Filipino ethnolinguistic groups by surveying complete mitochondrial DNA (mtDNA) genomes from a total of 14 groups (11 groups in this study and 3 groups previously published) including previously published mtDNA hypervariable segment (HVS) data from Filipino regional center groups. Comparison of HVS data indicate genetic differences between ethnolinguistic and regional center groups. The complete mtDNA genomes of 14 ethnolinguistic groups reveal genetic aspects consistent with the Y-chromosome, namely: diversity and heterogeneity of groups, no support for a simple dichotomy between Negrito and non-Negrito groups, and different genetic affinities with Asia-Pacific groups that are both ancient and recent. Although some mtDNA haplogroups can be associated with the Austronesian expansion, there are others that associate with South Asia, Near Oceania and Australia that are consistent with a southern migration route for ethnolinguistic group ancestors into the Asia-Pacific, with a timeline that overlaps with the initial colonization of the Asia-Pacific region, the initial colonization of the Philippines and a possible separate post-colonization migration into the Philippine archipelago. PMID:23756438
DEVELOPMENT OF AUTOMATED SOFTWARE PROGRAM FOR THE ANALYSIS OF ALZHEIMER'S DISEASE BETA-AMYLOID SCANS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mariotti, Jack; Zubal, George
2013-12-18
Study goal: A Phase 1 evaluation of the kinetics, clearance and cerebral distribution of one novel peripheral benzodiazepine receptors(PBR)positron emission tomography (PET) imaging agent, 18F-PBR-111 following intravenous administration in healthy volunteers and Alzheimer's disease (AD) patients. Short title: Evaluation of PET imaging with PBR-111 in HV and AD subjects Proof of Mechanism. Primary Objective: To evaluate the cerebral distribution of PBR-111 positron emission tomography (PET) for detection/exclusion of microglial activation in patients with Alzheimer's disease subjects compared to healthy volunteers. Secondary objectives: - To assess the dynamic uptake and washout of [18F]PBR-111, a potential imaging bio-marker for inflammatory changes inmore » brain, using positron emission tomography in subjects with Alzheimer's disease (AD) and healthy volunteers (HV). - To perform blood metabolite characterization of [18F]PBR-111 in subjects with AD and HV to determine the nature of metabolites in assessment of [18F]-PBR-111 as a PET brain imaging agent. Name of radioactive drug substance: PBR-111 Dose(s): The applied PBR-111 radioactive dose will be up to 5.0 mCi, diluted in a maximum of 10 ml of saline. The radioligand will be administered as a slow intravenous bolus injection (i.e., 6 sec/ml) into a large vein (e.g., antecubital vein). Route of administration: Intravenous injection Duration of treatment: Single administration of a diagnostic agent Indication: PBR-111 positron emission tomography (PET) imaging has the potential to detect microglial activation. In the presence of PBR-111 uptake (representative of microglial activation), inflammation in the brain can be detected. Diagnosis and main criteria for inclusion: Study participants will be HVs and patients diagnosed with probable AD. HVs must be 18 years of age (at least four subjects 50 years of age) and have no evidence of cognitive impairment or other neurologic disease by medical history. The lack of cognitive impairment will also be based on a Clinical Dementia Rating (CDR) of 0. Patients with probable AD must be 50 years of age and must fulfill the National Institute of Neurological and Communicative Disorders and Stroke, Alzheimer's Disease and Related Disorders Association [NINCDS-ADRDA] criteria for probable AD. The CDR score must be 1.0 and 2.0 and have a modified Hachinski of 4. All HVs and all patients with probable AD must be able to comply with all study procedures. Study design: This is a Phase 1, open-label, single-center, non-randomized single dose study to assess the kinetics, clearance and cerebral distribution of PBR-111 PET imaging in detecting microglial activation in the brain in patients with probable AD compared to HVs. All aspects related to image acquisition, processing, and visual as well as quantitative evaluation will be developed, optimized, and validated (where required). Each subject will be required to visit the study center during the screening phase and on the PBR-111 PET imaging day (baseline). A telephone follow-up visit will be performed 7 days (± 3 days) after PBR-111 PET administration. At the screening visit, each subject (or caregiver in the case of AD subjects) will be asked to provide written informed consent or assent. During the screening phase (maximum duration of 60 days) subject medical, neurological, and surgical history, clinical assessments, and a neuro-psychiatric evaluation will be performed on all eligible subjects. Subjects will be allowed to leave the center after all evaluations have been completed. During this period an MRI of the brain will be performed during the screening period. If an MRI of the brain has been performed within six months of the imaging visit using the methods described in the protocol, and there has been no medically significant events in the interim, the previous MRI may be used. During the PBR-111 PET imaging day, all subjects will receive a single intravenous injection of PBR-111 and scanning will be performed over a 3.5 hour period. Each subject will have a telephone follow-up 7 days (± 3 days) thereafter to assess for adverse events. Methodology: - Assessments to provide clinical characterization of the AD subjects will be performed. - After administration of PBR-111, images will be generated with state-of-the-art PET imaging. Images will be assessed quantitatively for the presence of microglial activation by a nuclear physician blinded to clinical data. - Total radioactivity and estimation of the fraction of radioactivity associated to the un-metabolized tracer will be determined. In addition, the metabolite patterns of PBR-111 are determined in venous plasma and arterial samples based on high-performance liquid chromatography (HPLC) analyses. - Arterial sampling will be acquired in the initial two AD and two HV subjects and modeling will be assessed to determine if additional arterial sampling is necessary.« less
Muraoka, Takayuki; Soh, Junichi; Toyooka, Shinichi; Aoe, Keisuke; Fujimoto, Nobukazu; Hashida, Shinsuke; Maki, Yuho; Tanaka, Norimitsu; Shien, Kazuhiko; Furukawa, Masashi; Yamamoto, Hiromasa; Asano, Hiroaki; Tsukuda, Kazunori; Kishimoto, Takumi; Otsuki, Takemi; Miyoshi, Shinichiro
2013-12-01
Malignant pleural mesothelioma (MPM) is an aggressive tumor with a poor prognosis. microRNA-34b/c (miR-34b/c), which plays an important role in the pathogenesis of MPM, is frequently downregulated by DNA methylation in approximately 90% of MPM cases. In this study, we estimated the degree of miR-34b/c methylation in serum-circulating DNA using a digital methylation specific PCR assay (MSP). A real-time MSP assay was performed using the SYBR Green method. The melting temperature (Tm) of each PCR product was examined using a melting curve analysis. For a digital MSP assay, 40 wells were analyzed per sample. A total of 110 serum samples from 48 MPM cases, 21 benign asbestos pleurisy (BAP) cases, and 41 healthy volunteers (HVs) were examined. Positive range of Tm value for miR-34b/c methylation was defined as 77.71-78.79 °C which was the mean ± 3 standard deviations of 40 wells of a positive control. The number of miR-34b/c methylated wells was counted per sample according to this criterion. The number of miR-34b/c methylated wells in MPM cases was significantly higher than that in BAP cases (P=0.03) or HVs (P<0.001). Advanced MPM cases tended to have higher number of miR-34b/c methylated wells than early MPM cases. Receiver-operating characteristic (ROC) curve analysis revealed that three number of miR-34b/c methylated wells per sample was the best cut-off of positivity of MPM with a 67% of sensitivity and a 77% specificity for prediction. The area under the ROC curve was 0.77. Our digital MSP assay can quantify miR-34b/c methylation in serum-circulating DNA. The degree of miR-34b/c methylation in serum-circulating DNA is associated with MPM, suggesting that this approach might be useful for the establishment of a new detection system for MPM. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Altered selection during language processing in individuals at high risk for psychosis.
Vargas, T; Snyder, H; Banich, M; Newberry, R; Shankman, Stewart A; Strauss, Gregory P; Mittal, V A
2018-06-19
Performance in the executive function (EF) domain has been linked to symptoms and functional outcomes in psychosis. Studies have found that UHR populations have difficulty with verbal fluency, which involves multiple facets of EF. Two potentially implicated EF facets were examined to explore whether these could be dissociated in UHR populations: selection among alternatives (measured by selection costs) and retrieval from semantic memory retrieval (measured by retrieval costs). A total of 45 UHR individuals and 46 healthy controls (HVs) were assessed with a verb generation task. Differences in selection cost (RT difference between high and low selection demand conditions) and retrieval cost (RT difference between high and low retrieval demand conditions) were examined and participants were also assessed for clinical symptoms. The UHR group showed greater selection costs relative to HVs, F (1, 91) = 4.39, p = 0.039. However, there were no group differences on retrieval cost, F (1, 91) = 0.63, p = 0.43. A positive association (r = 0.41) was found between disorganized and negative symptoms and selection costs (but not retrieval costs) in the UHR group. There was no significant association between selection costs and positive symptoms. Increased selection costs may reflect impaired performance in the neural inhibition domain of EF in the UHR population, potentially underlying a mechanistically distinct EF subdomain that affects the group's ability to efficiently select between competing options. Findings suggest that UHR individuals may exhibit impairment in selecting among alternatives, but not in retrieval from semantic memory. Copyright © 2018 Elsevier B.V. All rights reserved.
Perspectives of Low Socioeconomic Status Mothers of Premature Infants
Faherty, Laura J.; Wallace-Keeshen, Sara; Martin, Ashley E; Shea, Judy A.; Lorch, Scott A.
2017-01-01
BACKGROUND AND OBJECTIVES: Transitioning premature infants from the NICU to home is a high-risk period with potential for compromised care. Parental stress is high, and families of low socioeconomic status may face additional challenges. Home visiting programs have been used to help this transition, with mixed success. We sought to understand the experiences of at-risk families during this transition to inform interventions. METHODS: Mothers of infants born at <35 weeks’ gestation, meeting low socioeconomic status criteria, were interviewed by telephone 30 days after discharge to assess caregiver experiences of discharge and perceptions of home visitors (HVs). We generated salient themes by using grounded theory and the constant comparative method. Interviews were conducted until thematic saturation was achieved. RESULTS: Twenty-seven mothers completed interviews. Eighty-five percent were black, and 81% had Medicaid insurance. Concern about infants’ health and fragility was the primary theme identified, with mothers reporting substantial stress going from a highly monitored NICU to an unmonitored home. Issues with trust and informational consistency were mentioned frequently and could threaten mothers’ willingness to engage with providers. Strong family networks and determination compensated for limited economic resources, although many felt isolated. Mothers appreciated HVs’ ability to address infant health but preferred nurses over lay health workers. CONCLUSIONS: Low-income mothers experience significant anxiety about the transition from the NICU to home. Families value HVs who are trustworthy and have relevant medical knowledge about prematurity. Interventions to improve transition would benefit by incorporating parental input and facilitating trust and consistency in communication. PMID:28223372
Elkamel, Sarra; Boussetta, Sami; Khodjet-El-Khil, Houssein; Benammar Elgaaied, Amel; Cherni, Lotfi
2018-05-01
Through previous mitochondrial DNA studies, the Middle Eastern maternal genetic contribution to Tunisian populations appears limited. In fact, most of the studied communities were cosmopolitan, or of Berber or Andalusian origin. To provide genetic evidence for the actual contribution of Middle Eastern mtDNA lineages to Tunisia, we focused on two Arab speaking populations from Kairouan and Wesletia known to belong to an Arab genealogical lineage. A total of 114 samples were sequenced for the mtDNA HVS-I and HVS-II regions. Using these data, we evaluated the distribution of Middle Eastern haplogroups in the study populations, constructed interpolation maps, and established phylogenetic networks allowing estimation of the coalescence time for three specific Middle Eastern subclades (R0a, J1b, and T1). Both studied populations displayed North African genetic structure and Middle Eastern lineages with a frequency of 12% and 28.12% in Kairouan and Wesletia, respectively. TMRCA estimates for haplogroups T1a, R0a, and J1b in Tunisian Arabian samples were around 15 000 YBP, 9000 to 5000 YBP, and 960 to 600 YBP, respectively. The Middle Eastern maternal genetic contribution to Tunisian populations, as to other North African populations, occurred mostly in deep prehistory. They were brought in different migration waves during the Upper Paleolithic, probably with the expansion of Iberomaurusian culture, and during Epipaleolithic and Early Neolithic periods, which are concomitant with the Capsian civilization. Middle Eastern lineages also came to Tunisia during the recent Islamic expansion of the 7th CE and the subsequent massive Bedouin migration during the 11th CE. © 2018 Wiley Periodicals, Inc.
Mitochondrial DNA perspective of Serbian genetic diversity.
Davidovic, Slobodan; Malyarchuk, Boris; Aleksic, Jelena M; Derenko, Miroslava; Topalovic, Vladanka; Litvinov, Andrey; Stevanovic, Milena; Kovacevic-Grujicic, Natasa
2015-03-01
Although south-Slavic populations have been studied to date from various aspects, the population of Serbia, occupying the central part of the Balkan Peninsula, is still genetically understudied at least at the level of mitochondrial DNA (mtDNA) variation. We analyzed polymorphisms of the first and the second mtDNA hypervariable segments (HVS-I and HVS-II) and informative coding-region markers in 139 Serbians to shed more light on their mtDNA variability, and used available data on other Slavic and neighboring non-Slavic populations to assess their interrelations in a broader European context. The contemporary Serbian mtDNA profile is consistent with the general European maternal landscape having a substantial proportion of shared haplotypes with eastern, central, and southern European populations. Serbian population was characterized as an important link between easternmost and westernmost south-Slavic populations due to the observed lack of genetic differentiation with all other south-Slavic populations and its geographical positioning within the Balkan Peninsula. An increased heterogeneity of south Slavs, most likely mirroring turbulent demographic events within the Balkan Peninsula over time (i.e., frequent admixture and differential introgression of various gene pools), and a marked geographical stratification of Slavs to south-, east-, and west-Slavic groups, were also found. A phylogeographic analyses of 20 completely sequenced Serbian mitochondrial genomes revealed not only the presence of mtDNA lineages predominantly found within the Slavic gene pool (U4a2a*, U4a2a1, U4a2c, U4a2g, HV10), supporting a common Slavic origin, but also lineages that may have originated within the southern Europe (H5*, H5e1, H5a1v) and the Balkan Peninsula in particular (H6a2b and L2a1k). © 2014 Wiley Periodicals, Inc.
Grzybowski, Tomasz; Malyarchuk, Boris A; Derenko, Miroslava V; Perkova, Maria A; Bednarek, Jarosław; Woźniak, Marcin
2007-06-01
Mitochondrial DNA sequence variation was examined by the control region sequencing (HVS I and HVS II) and RFLP analysis of haplogroup-diagnostic coding region sites in 570 individuals from four regional populations of Poles and two Russian groups from northwestern part of the country. Additionally, sequences of complete mitochondrial genomes representing K1a1b1a subclade in Polish and Polish Roma populations have been determined. Haplogroup frequency patterns revealed in Poles and Russians are similar to those characteristic of other Europeans. However, there are several features of Slavic mtDNA pools seen on the level of regional populations which are helpful in the understanding of complex interactions of the Eastern and Western Slavic populations with other European groups. One of the most important is the presence of subhaplogroups U5b1b1, D5, Z1 and U8a with simultaneous scarcity of haplogroup K in populations of northwestern Russia suggesting the participation of Finno-Ugrian tribes in the formation of mtDNA pools of Russians from this region. The results of genetic structure analyses suggest that Russians from Velikii Novgorod area (northwestern Russia) and Poles from Suwalszczyzna (northeastern Poland) differ from all remaining Polish and Russian samples. Simultaneously, northwestern Russians and northeastern Poles bear some similarities to Baltic (Latvians) and Finno-Ugrian groups (Estonians) of northeastern Europe, especially on the level of U5 haplogroup frequencies. The occurrence of K1a1b1a subcluster in Poles and Polish Roma is one of the first direct proofs of the presence of Ashkenazi-specific mtDNA lineages in non-Jewish European populations.
Sex-specific genetic diversity is shaped by cultural factors in Inner Asian human populations.
Marchi, Nina; Hegay, Tatyana; Mennecier, Philippe; Georges, Myriam; Laurent, Romain; Whitten, Mark; Endicott, Philipp; Aldashev, Almaz; Dorzhu, Choduraa; Nasyrova, Firuza; Chichlo, Boris; Ségurel, Laure; Heyer, Evelyne
2017-04-01
Sex-specific genetic structures have been previously documented worldwide in humans, even though causal factors have not always clearly been identified. In this study, we investigated the impact of ethnicity, geography and social organization on the sex-specific genetic structure in Inner Asia. Furthermore, we explored the process of ethnogenesis in multiple ethnic groups. We sampled DNA in Central and Northern Asia from 39 populations of Indo-Iranian and Turkic-Mongolic native speakers. We focused on genetic data of the Y chromosome and mitochondrial DNA. First, we compared the frequencies of haplogroups to South European and East Asian populations. Then, we investigated the genetic differentiation for eight Y-STRs and the HVS1 region, and tested for the effect of geography and ethnicity on such patterns. Finally, we reconstructed the male demographic history, inferred split times and effective population sizes of different ethnic groups. Based on the haplogroup data, we observed that the Indo-Iranian- and Turkic-Mongolic-speaking populations have distinct genetic backgrounds. However, each population showed consistent mtDNA and Y chromosome haplogroups patterns. As expected in patrilocal populations, we found that the Y-STRs were more structured than the HVS1. While ethnicity strongly influenced the genetic diversity on the Y chromosome, geography better explained that of the mtDNA. Furthermore, when looking at various ethnic groups, we systematically found a genetic split time older than historical records, suggesting a cultural rather than biological process of ethnogenesis. This study highlights that, in Inner Asia, specific cultural behaviors, especially patrilineality and patrilocality, leave a detectable signature on the sex-specific genetic structure. © 2017 Wiley Periodicals, Inc.
Predicting the hypervelocity star population in Gaia
NASA Astrophysics Data System (ADS)
Marchetti, T.; Contigiani, O.; Rossi, E. M.; Albert, J. G.; Brown, A. G. A.; Sesana, A.
2018-06-01
Hypervelocity stars (HVSs) are amongst the fastest objects in our Milky Way. These stars are predicted to come from the Galactic centre (GC) and travel along unbound orbits across the Galaxy. In the coming years, the ESA satellite Gaia will provide the most complete and accurate catalogue of the Milky Way, with full astrometric parameters for more than 1 billion stars. In this paper, we present the expected sample size and properties (mass, magnitude, spatial, velocity distributions) of HVSs in the Gaia stellar catalogue. We build three Gaia mock catalogues of HVSs anchored to current observations, exploring different ejection mechanisms and GC stellar population properties. In all cases, we predict hundreds to thousands of HVSs with precise proper motion measurements within a few tens of kpc from us. For stars with a relative error in total proper motion below 10 {per cent}, the mass range extends to ˜10 M⊙ but peaks at ˜1 M⊙. The majority of Gaia HVSs will therefore probe a different mass and distance range compared to the current non-Gaia sample. In addition, a subset of a few hundreds to a few thousands of HVSs with M ˜ 3 M⊙ will be bright enough to have a precise measurement of the three-dimensional velocity from Gaia alone. Finally, we show that Gaia will provide more precise proper motion measurements for the current sample of HVS candidates. This will help identifying their birthplace narrowing down their ejection location, and confirming or rejecting their nature as HVSs. Overall, our forecasts are extremely encouraging in terms of quantity and quality of HVS data that can be exploited to constrain both the Milky Way potential and the GC properties.
Martinucci, I; de Bortoli, N; Savarino, E; Piaggi, P; Bellini, M; Antonelli, A; Savarino, V; Frazzoni, M; Marchi, S
2014-04-01
Recently, it has been suggested that low esophageal basal impedance may reflect impaired mucosal integrity and increased acid sensitivity. We aimed to compare baseline impedance levels in patients with heartburn and pathophysiological characteristics related to functional heartburn (FH) divided into two groups on the basis of symptom relief after proton pump inhibitors (PPIs). Patients with heartburn and negative endoscopy were treated with esomeprazole or pantoprazole 40 mg daily for 8 weeks. According to MII-pH (off therapy) analysis, patients with normal acid exposure time (AET), normal reflux number, and lack of association between symptoms and refluxes were selected; of whom 30 patients with a symptom relief higher than 50% after PPIs composed Group A, and 30 patients, matched for sex and age, without symptom relief composed Group B. A group of 20 healthy volunteers (HVs) was enrolled. For each patient and HV, we evaluated the baseline impedance levels at channel 3, during the overnight rest, at three different times. Group A (vs Group B) showed an increase in the following parameters: mean AET (1.4 ± 0.8% vs 0.5 ± 0.6%), mean reflux number (30.4 ± 8.7 vs 24 ± 6.9), proximal reflux number (11.1 ± 5.2 vs 8.2 ± 3.6), acid reflux number (17.9 ± 6.1 vs 10.7 ± 6.9). Baseline impedance levels were lower in Group A than in Group B and in HVs (p < 0.001). Evaluating baseline impedance levels in patients with heartburn and normal AET could achieve a better understanding of pathophysiology in reflux disease patients, and could improve the distinction between FH and hypersensitive esophagus. © 2014 John Wiley & Sons Ltd.
Matsumura, Takuma; Kinoshita, Taku; Sakurai, Yoriko; Yahaba, Misuzu; Tsushima, Kenji; Sakao, Seiichiro; Nagashima, Kengo; Ozaki, Toshinori; Kobayashi, Yoshio; Hiwasa, Takaki; Tatsumi, Koichiro
2018-01-01
Objective Although severe obstructive sleep apnea (OSA) is an important risk factor for atherosclerosis-related diseases including coronary artery disease (CAD), there is no reliable biomarker of CAD risks in patients with OSA. This study aimed to test our hypothesis that circulating autoantibodies against neuroblastoma suppressor of tumorigenicity 1 (NBL1-Abs) are associated with the prevalence of CAD in patients with OSA. Methods Eighty-two adults diagnosed with OSA by polysomnography, 96 patients with a diagnosis of acute coronary syndrome (ACS) and 64 healthy volunteers (HVs) were consecutively enrolled. Serum samples were collected from patients with OSA at diagnostic polysomnography and from patients with ACS at disease onset. Serum NBL1-Ab level was measured by amplified luminescence proximity homogeneous assay and its association with clinical variables related to atherosclerosis was evaluated. Results NBL1-Ab level was significantly elevated in patients with both OSA and ACS compared with HVs. Subgroup analyses showed that NBL1-Ab level was markedly higher in patients with severe OSA and OSA patients with a history of CAD. Weak associations were observed between NBL1-Ab level and apnea-hypopnea index, age, mean SpO2 and arousal index, whereas significantly higher NBL1-Ab levels were observed in OSA patients with a history of CAD than in those without a history of CAD. Sensitivity analysis using a logistic regression model also demonstrated that increased NBL1-Ab levels were associated with the previous history of CAD in patients with OSA. Conclusions Elevated NBL1-Ab levels may be associated with the prevalence of CAD in patients with OSA, which needs to be confirmed further. PMID:29596467
van Doorn, Martijn; Vogels, Jack; Tas, Albert; van Hoogdalem, Ewoud Jan; Burggraaf, Jacobus; Cohen, Adam; van der Greef, Jan
2007-05-01
* Many studies have investigated the effects of thiazolidinediones on isolated biochemical markers (biomarkers) or sets of markers in Type 2 diabetes mellitus (T2DM) patients and healthy volunteers. * However, a limited number of parameters is not capable of capturing the broad response to pharmacological intervention with these types of (pleiotropic) drugs, which are known to activate the nuclear transcription factor peroxisome proliferator activated receptor gamma (PPARgamma). * Our study tested the new hypothesis (primary objective) that nuclear magnetic resonance (NMR)-based metabolomics, capable of providing a readout of global metabolite concentrations in biofluids, could provide a better (more holistic) picture of the the multiparametric response to pharmacological intervention with a PPARgamma agonist and thus yield a broad array of biomarkers ('fingerprint') that could be used to support and expedite clinical development of novel thiazolidinediones. * NMR-based metabolomics coupled with sophisticated bioinformatics is indeed capable of identifying rapid changes in global metabolite profiles in urine and plasma (treatment 'fingerprints'), which may be linked to the well-documented early changes in hepatic insulin senstitivity following thiazolidinedione intervention in T2DM patients. * Consequently, this approach (upon proper validation) comprises an important new addition to the early clinical development 'proof of concept' toolbox for thiazolidinediones, and may also be applicable to other classes of drugs. To explore the usefulness of metabolomics as a method to obtain a broad array of biomarkers for the pharmacological effects of rosiglitazone (RSG) in plasma and urine samples from patients with type 2 diabetes mellitus (T2DM) and healthy volunteers (HVs). Additionally, we explored the differences in metabolite concentrations between T2DM patients and HVs to identify a putative metabolic disease fingerprint for T2DM. (1)H nuclear magnetic resonance (NMR) spectroscopy was used to profile blood plasma and urine samples of 16 T2DM patients and 16 HVs receiving RSG 4 mg or placebo twice daily for 6 weeks. Multivariate analyses were employed to identify treatment- and disease-related effects on global endogenous metabolite profiles. RSG treatment led to a rapid relative reduction in urinary hippurate and aromatic amino acids as well as an increase in plasma branched chain amino acids and alanine, glutamine and glutamate in the T2DM group. No RSG treatment effects were noted in the HV group. Exploratory baseline analyses showed that urine and plasma metabolites discriminated between genders and disease state. T2DM patients showed a relative increase in urinary concentrations of several amino acids, citrate, phospho(enol)pyruvate and hippurate. Putative T2DM-related changes in plasma were largely attributable to increased plasma lipids. The results of this study indicate that NMR-based metabolomics of urine and blood plasma samples can yield a broad array of early responding biomarkers for the effects of RSG in T2DM patients, as well as nonglucose biomarkers that may reflect the T2DM state.
The Visual Scoring of Sleep in Infants 0 to 2 Months of Age.
Grigg-Damberger, Madeleine M
2016-03-01
In March 2014, the American Academy of Sleep Medicine (AASM) Board of Directors requested the Scoring Manual Editorial Board develop rules, terminology, and technical specifications for scoring sleep/wake states in full-term infants from birth to 2 mo of age, cognizant of the 1971 Anders, Emde, and Parmelee Manual for Scoring Sleep in Newborns. On July 1, 2015, the AASM published rules for scoring sleep in infants, ages 0-2 mo. This evidence-based review summarizes the background information provided to the Scoring Manual Editorial Board to write these rules. The Anders Manual only provided criteria for coding physiological and behavioral state characteristics in polysomnograms (PSG) of infants, leaving specific sleep scoring criteria to the individual investigator. Other infant scoring criteria have been published, none widely accepted or used. The AASM Scoring Manual infant scoring criteria incorporate modern concepts, digital PSG recording techniques, practicalities, and compromises. Important tenets are: (1) sleep/wake should be scored in 30-sec epochs as either wakefulness (W), rapid eye movement, REM (R), nonrapid eye movement, NREM (N) and transitional (T) sleep; (2) an electroencephalographic (EEG) montage that permits adequate display of young infant EEG is: F3-M2, F4-M1, C3-M2, C4-M1, O1-M2, O2-M1; additionally, recording C3-Cz, Cz-C4 help detect early and asynchronous sleep spindles; (3) sleep onsets are more often R sleep until 2-3 mo postterm; (4) drowsiness is best characterized by visual observation (supplemented by later video review); (5) wide open eyes is the most crucial determinant of W; (6) regularity (or irregularity) of respiration is the single most useful PSG characteristic for scoring sleep stages at this age; (7) trace alternant (TA) is the only relatively distinctive EEG pattern, characteristic of N sleep, and usually disappears by 1 mo postterm replaced by high voltage slow (HVS); (8) sleep spindles first appear 44-48 w conceptional age (CA) and when present prompt scoring N; (9) score EEG activity in an epoch as "continuous" or "discontinuous" for inter-scorer reliability; (10) score R if four or more of the following conditions are present, including irregular respiration and rapid eye movement(s): (a) low chin EMG (for the majority of the epoch); (b) eyes closed with at least one rapid eye movement (concurrent with low chin tone); (c) irregular respiration; (d) mouthing, sucking, twitches, or brief head movements; and (e) EEG exhibits a continuous pattern without sleep spindles; (11) because rapid eye movements may not be seen on every page, epochs following an epoch of definite R in the absence of rapid eye movements may be scored if the EEG is continuous without TA or sleep spindles, chin muscle tone low for the majority of the epoch; and there is no intervening arousal; (12) Score N if four or more of the following conditions are present, including regular respiration, for the majority of the epoch: (a) eyes are closed with no eye movements; (b) chin EMG tone present; (c) regular respiration; and (d) EEG patterns of either TA, HVS, or sleep spindles are present; and (13) score T sleep if an epoch contains two or more discordant PSG state characteristics (either three NREM and two REM characteristics or two NREM and three REM characteristics). These criteria for ages 0-2 mo represent far more than baby steps. Like all the other AASM Manual rules and specifications none are fixed in stone, all open for debate, discussion and revision with the fundamental goal to provide standards for comparison of methods and results. A commentary on this article appears in this issue on page 291. © 2016 American Academy of Sleep Medicine.
Furtado, Agustin; Torres, Fabrício Dias; Franco, Ana Cláudia; Maisonnave, Jacqueline; Roehe, Paulo Michel
2016-01-01
Bovine herpesviruses (BoHVs) types 1 (BoHV-1) and 5 (BoHV-5) are alphaherpesviruses of major importance to the bovine production chain. Such viruses are capable of establishing latent infections in neuronal tissues. Infected animals tend to develop a serological response to infection; however, such response—usually investigated by antibody assays in serum—may eventually not be detected in laboratory assays. Nevertheless, serological tests such as virus neutralization (VN) and various enzyme-linked immunosorbent assays (ELISAs) are widely employed to check individual or herd status of BoHV infections. The correlation between detection of antibodies and the presence of viral nucleic acids as indicatives of infection in infected cattle has not been deeply examined. In order to investigate such correlation, 248 bovine serum samples were tested by VN to BoHV-1 and BoHV-5, as well as in a widely employed (though not type-differential) gB ELISA (IDEXX IBR gB X2 Ab Test) in search for antibodies to BoHVs. Immediately after blood withdrawal, cattle were slaughtered and trigeminal ganglia (TG) excised for DNA extraction and viral nucleic acid detection (NAD) by nested PCR. Neutralizing antibodies to BoHV-1 and/or BoHV-5 were detected in 44.8% (111/248) of sera, whereas the gB ELISA detected antibodies in 51.2% (127/248) of the samples. However, genomes of either BoHV-1, BoHV-5, or both, were detected in TGs of 85.9% (213/248) of the animals. These findings reveal that the assays designed to detect antibodies to BoHV-1 and/or BoHV-5 employed here may fail to detect a significant number of latently infected animals (in this study, 35.7%). From such data, it is clear that antibody assays are poorly correlated with detection of viral genomes in BoHV-1 and BoHV-5-infected animals. PMID:27224314
Heavy truck restrictions and air quality implications in São Paulo, Brazil.
Pérez-Martínez, Pedro José; de Fátima Andrade, María; de Miranda, Regina Maura
2017-11-01
This study quantified the effects of traffic restrictions on diesel fuel heavy vehicles (HVs) on the air quality of the Bandeirantes corridor using hourly data obtained by continuous monitoring of traffic and air quality at sites located on this avenue. The study addressed the air quality of a city impacted by vehicular emissions and that PM 10 and NO X concentrations are mainly due to diesel burning. Data collection was split into two time periods, a period of no traffic constraint on HVs (Nov 2008 and 2009) and a period of constraint (Nov 2010, 2011 and 2012). We found that pollutants on this corridor, mainly PM 10 and NO X , decreased significantly during the period from 2008 to 2012 (28 and 43%, 15.8 and 86.9 ppb) as a direct consequence of HV traffic restrictions (a 72% reduction). Rebound effects in the form of increased traffic of light vehicles (LVs) during this time had impacts on the concentration levels, explaining the differences between rates of reduction in HV traffic and pollutants. Reductions in the number of trucks resulted in longer travel times and increased traffic congestion as a consequence of the modal shift towards LVs. We found that a 51% decrease in PM 10 (28.8 μg m -3 ) was due to a reduction in HV traffic (vehicle emissions were estimated to be 71% of total sources, 40.1 μg m -3 ). This percentage was partially offset by 10% more PM 10 emissions related to an increase in LV traffic, while other causes, such as climatic conditions, contributed to a 13% increase in PM 10 concentrations. The relationships analyzed in this research served to highlight the need to apply urban transport policies aimed at decreasing pollutant concentrations in São Paulo, especially in heavily congested urban corridors on working days. Copyright © 2017 Elsevier Ltd. All rights reserved.
2011-01-01
Arsenic is the toxic element, which creates several problems in human being specially when inhaled through air. So the accurate and precise measurement of arsenic in suspended particulate matter (SPM) is of prime importance as it gives information about the level of toxicity in the environment, and preventive measures could be taken in the effective areas. Quality assurance is equally important in the measurement of arsenic in SPM samples before making any decision. The quality and reliability of the data of such volatile elements depends upon the measurement of uncertainty of each step involved from sampling to analysis. The analytical results quantifying uncertainty gives a measure of the confidence level of the concerned laboratory. So the main objective of this study was to determine arsenic content in SPM samples with uncertainty budget and to find out various potential sources of uncertainty, which affects the results. Keeping these facts, we have selected seven diverse sites of Delhi (National Capital of India) for quantification of arsenic content in SPM samples with uncertainty budget following sampling by HVS to analysis by Atomic Absorption Spectrometer-Hydride Generator (AAS-HG). In the measurement of arsenic in SPM samples so many steps are involved from sampling to final result and we have considered various potential sources of uncertainties. The calculation of uncertainty is based on ISO/IEC17025: 2005 document and EURACHEM guideline. It has been found that the final results mostly depend on the uncertainty in measurement mainly due to repeatability, final volume prepared for analysis, weighing balance and sampling by HVS. After the analysis of data of seven diverse sites of Delhi, it has been concluded that during the period from 31st Jan. 2008 to 7th Feb. 2008 the arsenic concentration varies from 1.44 ± 0.25 to 5.58 ± 0.55 ng/m3 with 95% confidence level (k = 2). PMID:21466671
Neuronal surface antibodies in HIV-infected patients with isolated psychosis.
Cunill, Vanessa; Arboleya, Susana; Jiménez, Maria de Los Reyes; Campins, Antoni; Herbera, Patricia; Mestre, LLuïsa; Clemente, Antonio; Barceló, Maria Inés; Leyes, Maria; Canellas, Francesca; Julià, Maria Rosa
2016-12-15
Neuronal surface antibodies (NSA) involved in autoimmune encephalitis (AE) have been related to relapses in HVS encephalitis. Their role in non-encephalitic psychosis is controversial. We previously reported an HIV-infected patient, NSA-positive, only presenting psychosis. Therefore, we determined the NSA prevalence in a prospective cohort of 22 HIV-positive patients with psychosis and we analyzed the frequency of HIV infection among NSA tested patients due to AE suspicion. We found no NSA in the prospective cohort. In the retrospective analysis, 22% of NSA-positive versus 4.6% of negative patients were HIV-positive. Wider studies are required to clarify the relationship between NSA and HIV infection. Copyright © 2016 Elsevier B.V. All rights reserved.
The high vaginal swab in general practice: clinical correlates of possible pathogens.
Dykhuizen, R S; Harvey, G; Gould, I M
1995-06-01
Clinical features, diagnosis and treatment of 286 women whose high vaginal swabs (HVS) submitted by their general practitioners showed pure, heavy growth of Staphylococcus aureus, beta haemolytic streptococci groups A, C or G, Streptococcus milleri, Streptococcus pneumoniae or Haemophilus influenzae were analysed. Women with group A, C and G streptococci frequently had clinical vulvovaginitis and although the numbers were too small for statistical confirmation, S. pneumoniae and H. influenzae appeared to cause clinical disease as well. The association of S. aureus or S. milleri with clinical vulvovaginitis was much less convincing. It seems relevant for laboratories to report sensitivities for group A, C and G streptococci. Further research is needed to determine the pathogenicity of S. pneumoniae and H. influenzae.
NASA Astrophysics Data System (ADS)
Tapia Gutierrez, Patricio Enrique
Whitetopping (WT) is a rehabilitation method to resurface deteriorated asphalt pavements. While some of these composite pavements have performed very well carrying heavy load, other have shown poor performance with early cracking. With the objective of analyzing the applicability of WT pavements under Florida conditions, a total of nine full-scale WT test sections were constructed and tested using a Heavy Vehicle Simulator (HVS) in the APT facility at the FDOT Material Research Park. The test sections were instrumented to monitor both strain and temperature. A 3-D finite element model was developed to analyze the WT test sections. The model was calibrated and verified using measured FWD deflections and HVS load-induced strains from the test sections. The model was then used to evaluate the potential performance of these test sections under critical temperature-load condition in Florida. Six of the WT pavement test sections had a bonded concrete-asphalt interface by milling, cleaning and spraying with water the asphalt surface. This method produced excellent bonding at the interface, with shear strength of 195 to 220 psi. Three of the test sections were intended to have an unbonded concrete-asphalt interface by applying a debonding agent in the asphalt surface. However, shear strengths between 119 and 135 psi and a careful analysis of the strain and the temperature data indicated a partial bond condition. The computer model was able to satisfactorily model the behavior of the composite pavement by mainly considering material properties from standard laboratory tests and calibrating the spring elements used to model the interface. Reasonable matches between the measured and the calculated strains were achieved when a temperature-dependent AC elastic modulus was included in the analytical model. The expected numbers of repetitions of the 24-kip single axle loads at critical thermal condition were computed for the nine test sections based on maximum tensile stresses and fatigue theory. The results showed that 4" slabs can be used for heavy loads only for low-volume traffic. To withstand the critical load without fear of fatigue failure, 6" slabs and 8" slabs would be needed for joint spacings of 4' and 6', respectively.
The Genetic Legacy of the Pre-Colonial Period in Contemporary Bolivians
Vidal-Bralo, Laura; Gómez-Carballa, Alberto; Catelli, Laura; Pardo-Seco, Jacobo; Pastoriza, Ana; Carracedo, Ángel; Torres-Balanza, Antonio; Rocabado, Omar; Vullo, Carlos
2013-01-01
Only a few genetic studies have been carried out to date in Bolivia. However, some of the most important (pre)historical enclaves of South America were located in these territories. Thus, the (sub)-Andean region of Bolivia was part of the Inca Empire, the largest state in Pre-Columbian America. We have genotyped the first hypervariable region (HVS-I) of 720 samples representing the main regions in Bolivia, and these data have been analyzed in the context of other pan-American samples (>19,000 HVS-I mtDNAs). Entire mtDNA genome sequencing was also undertaken on selected Native American lineages. Additionally, a panel of 46 Ancestry Informative Markers (AIMs) was genotyped in a sub-set of samples. The vast majority of the Bolivian mtDNAs (98.4%) were found to belong to the main Native American haplogroups (A: 14.3%, B: 52.6%, C: 21.9%, D: 9.6%), with little indication of sub-Saharan and/or European lineages; however, marked patterns of haplogroup frequencies between main regions exist (e.g. haplogroup B: Andean [71%], Sub-Andean [61%], Llanos [32%]). Analysis of entire genomes unraveled the phylogenetic characteristics of three Native haplogroups: the pan-American haplogroup B2b (originated ∼21.4 thousand years ago [kya]), A2ah (∼5.2 kya), and B2o (∼2.6 kya). The data suggest that B2b could have arisen in North California (an origin even in the north most region of the American continent cannot be disregarded), moved southward following the Pacific coastline and crossed Meso-America. Then, it most likely spread into South America following two routes: the Pacific path towards Peru and Bolivia (arriving here at about ∼15.2 kya), and the Amazonian route of Venezuela and Brazil southwards. In contrast to the mtDNA, Ancestry Informative Markers (AIMs) reveal a higher (although geographically variable) European introgression in Bolivians (25%). Bolivia shows a decreasing autosomal molecular diversity pattern along the longitudinal axis, from the Altiplano to the lowlands. Both autosomes and mtDNA revealed a low impact (1–2%) of a sub-Saharan component in Bolivians. PMID:23527064
The genetic legacy of the pre-colonial period in contemporary Bolivians.
Taboada-Echalar, Patricia; Alvarez-Iglesias, Vanesa; Heinz, Tanja; Vidal-Bralo, Laura; Gómez-Carballa, Alberto; Catelli, Laura; Pardo-Seco, Jacobo; Pastoriza, Ana; Carracedo, Angel; Torres-Balanza, Antonio; Rocabado, Omar; Vullo, Carlos; Salas, Antonio
2013-01-01
Only a few genetic studies have been carried out to date in Bolivia. However, some of the most important (pre)historical enclaves of South America were located in these territories. Thus, the (sub)-Andean region of Bolivia was part of the Inca Empire, the largest state in Pre-Columbian America. We have genotyped the first hypervariable region (HVS-I) of 720 samples representing the main regions in Bolivia, and these data have been analyzed in the context of other pan-American samples (>19,000 HVS-I mtDNAs). Entire mtDNA genome sequencing was also undertaken on selected Native American lineages. Additionally, a panel of 46 Ancestry Informative Markers (AIMs) was genotyped in a sub-set of samples. The vast majority of the Bolivian mtDNAs (98.4%) were found to belong to the main Native American haplogroups (A: 14.3%, B: 52.6%, C: 21.9%, D: 9.6%), with little indication of sub-Saharan and/or European lineages; however, marked patterns of haplogroup frequencies between main regions exist (e.g. haplogroup B: Andean [71%], Sub-Andean [61%], Llanos [32%]). Analysis of entire genomes unraveled the phylogenetic characteristics of three Native haplogroups: the pan-American haplogroup B2b (originated ∼21.4 thousand years ago [kya]), A2ah (∼5.2 kya), and B2o (∼2.6 kya). The data suggest that B2b could have arisen in North California (an origin even in the north most region of the American continent cannot be disregarded), moved southward following the Pacific coastline and crossed Meso-America. Then, it most likely spread into South America following two routes: the Pacific path towards Peru and Bolivia (arriving here at about ∼15.2 kya), and the Amazonian route of Venezuela and Brazil southwards. In contrast to the mtDNA, Ancestry Informative Markers (AIMs) reveal a higher (although geographically variable) European introgression in Bolivians (25%). Bolivia shows a decreasing autosomal molecular diversity pattern along the longitudinal axis, from the Altiplano to the lowlands. Both autosomes and mtDNA revealed a low impact (1-2%) of a sub-Saharan component in Bolivians.
Zhu, You-Gen; Zhou, Jun-Fu; Shan, Wei-Ying; Zhou, Pei-Su; Tong, Gui-Zhong
2004-12-01
To investigate whether photochemical smog emitted during the process of electric arc welding might cause oxidative stress and potential oxidative damage in the bodies of welding operators. Seventy electric arc welding operators (WOs) and 70 healthy volunteers (HVs) were enrolled in a randomized controlled study design, in which the levels of vitamin C (VC) and vitamin E (VE) in plasma as well as the activities of superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPX), and the level of lipoperoxide (LPO) in erythrocytes were determined by spectrophotometry. Compared with the average values of the above experimental parameters in the HVs group, the average values of VC and VE in plasma as well as those of SOD, CAT and GPX in erythrocytes in the WOs group were significantly decreased (P < 0.005-0.0001), while the average value of LPO in erythrocytes in the WOs group was significantly increased (P < 0.0001). The findings from the partial correlation analysis on the controlling of age suggested that with a prolonged duration of exposure to photochemical smog the values of VC, VE, SOD, and GPX, except for CAT, in the WOs were decreased gradually (P < 0.05-0.005), the value of LPO in the WOs was increased gradually (P < 0.001), and that with the ozone dose increased in the air in each worksite VC, VE, SOD, CAT and GPX decreased (P < 0.005-0.001), but LPO increased (P < 0.001). The findings from the reliability analysis for the VC, VE, SOD, CAT, GPX, and LPO values which were used to reflect oxidative stress and potential oxidative damage in the WOs showed that the reliability coefficients' alpha (6 items) was 0.8021, P < 0.0001, and that the standardized item alpha was 0.9577, P < 0.0001. Findings in the present study suggest that there exists an oxidative stress induced by long-term exposure to photochemical smog in the bodies of WOs, thereby causing potential oxidative and lipoperoxidative damages in their bodies.
Origgi, Francesco C.; Tecilla, Marco; Pilo, Paola; Aloisio, Fabio; Otten, Patricia; Aguilar-Bultet, Lisandra; Sattler, Ursula; Roccabianca, Paola; Romero, Carlos H.; Bloom, David C.; Jacobson, Elliott R.
2015-01-01
We report the first de novo sequence assembly and analysis of the genome of Testudinid herpesvirus 3 (TeHV3), one of the most pathogenic chelonian herpesviruses. The genome of TeHV3 is at least 150,080 nucleotides long, is arranged in a type D configuration and comprises at least 102 open reading frames extensively co-linear with those of Human herpesvirus 1. Consistently, the phylogenetic analysis positions TeHV3 among the Alphaherpesvirinae, closely associated with Chelonid herpesvirus 5, a Scutavirus. To date, there has been limited genetic characterization of TeHVs and a resolution beyond the genotype was not feasible because of the lack of informative DNA sequences. To exemplify the potential benefits of the novel genomic information provided by this first whole genome analysis, we selected the glycoprotein B (gB) gene, for detailed comparison among different TeHV3 isolates. The rationale for selecting gB is that it encodes for a well-conserved protein among herpesviruses but is coupled with a relevant antigenicity and is consequently prone to accumulate single nucleotide polymorphisms. These features were considered critical for an ideal phylogenetic marker to investigate the potential existence of distinct TeHV3 genogroups and their associated pathology. Fifteen captive tortoises presumptively diagnosed to be infected with TeHVs or carrying compatible lesions on the basis of either the presence of intranuclear inclusions (presumptively infected) and/or diphtheronecrotic stomatitis-glossitis or pneumonia (compatible lesions) were selected for the study. Viral isolation, TeHV identification, phylogenetic analysis and pathological characterization of the associated lesions, were performed. Our results revealed 1) the existence of at least two distinct TeHV3 genogroups apparently associated with different pathologies in tortoises and 2) the first evidence for a putative homologous recombination event having occurred in a chelonian herpesvirus. This novel information is not only fundamental for the genetic characterization of this virus but is also critical to lay the groundwork for an improved understanding of host-pathogen interactions in chelonians and contribute to tortoise conservation. PMID:26244892
2013-01-01
Background Mitochondrial DNA (mtDNA) typing can be a useful aid for identifying people from compromised samples when nuclear DNA is too damaged, degraded or below detection thresholds for routine short tandem repeat (STR)-based analysis. Standard mtDNA typing, focused on PCR amplicon sequencing of the control region (HVS I and HVS II), is limited by the resolving power of this short sequence, which misses up to 70% of the variation present in the mtDNA genome. Methods We used in-solution hybridisation-based DNA capture (using DNA capture probes prepared from modern human mtDNA) to recover mtDNA from post-mortem human remains in which the majority of DNA is both highly fragmented (<100 base pairs in length) and chemically damaged. The method ‘immortalises’ the finite quantities of DNA in valuable extracts as DNA libraries, which is followed by the targeted enrichment of endogenous mtDNA sequences and characterisation by next-generation sequencing (NGS). Results We sequenced whole mitochondrial genomes for human identification from samples where standard nuclear STR typing produced only partial profiles or demonstrably failed and/or where standard mtDNA hypervariable region sequences lacked resolving power. Multiple rounds of enrichment can substantially improve coverage and sequencing depth of mtDNA genomes from highly degraded samples. The application of this method has led to the reliable mitochondrial sequencing of human skeletal remains from unidentified World War Two (WWII) casualties approximately 70 years old and from archaeological remains (up to 2,500 years old). Conclusions This approach has potential applications in forensic science, historical human identification cases, archived medical samples, kinship analysis and population studies. In particular the methodology can be applied to any case, involving human or non-human species, where whole mitochondrial genome sequences are required to provide the highest level of maternal lineage discrimination. Multiple rounds of in-solution hybridisation-based DNA capture can retrieve whole mitochondrial genome sequences from even the most challenging samples. PMID:24289217
The fate of close encounters between binary stars and binary supermassive black holes
NASA Astrophysics Data System (ADS)
Wang, Yi-Han; Leigh, Nathan; Yuan, Ye-Fei; Perna, Rosalba
2018-04-01
The evolution of main-sequence binaries that reside in the Galactic Centre can be heavily influenced by the central supermassive black hole (SMBH). Due to these perturbative effects, the stellar binaries in dense environments are likely to experience mergers, collisions, or ejections through secular and/or non-secular interactions. More direct interactions with the central SMBH are thought to produce hypervelocity stars (HVSs) and tidal disruption events (TDEs). In this paper, we use N-body simulations to study the dynamics of stellar binaries orbiting a central SMBH primary with an outer SMBH secondary orbiting this inner triple. The effects of the secondary SMBH on the event rates of HVSs, TDEs, and stellar mergers are investigated, as a function of the SMBH-SMBH binary mass ratio. Our numerical experiments reveal that, relative to the isolated SMBH case, the TDE and HVS rates are enhanced for, respectively, the smallest and largest mass ratio SMBH-SMBH binaries. This suggests that the observed event rates of TDEs and HVSs have the potential to serve as a diagnostic of the mass ratio of a central SMBH-SMBH binary. The presence of a secondary SMBH also allows for the creation of hypervelocity binaries. Observations of these systems could thus constrain the presence of a secondary SMBH in the Galactic Centre.
NASA Astrophysics Data System (ADS)
Rubel, Aleksey S.; Lukin, Vladimir V.; Egiazarian, Karen O.
2015-03-01
Results of denoising based on discrete cosine transform for a wide class of images corrupted by additive noise are obtained. Three types of noise are analyzed: additive white Gaussian noise and additive spatially correlated Gaussian noise with middle and high correlation levels. TID2013 image database and some additional images are taken as test images. Conventional DCT filter and BM3D are used as denoising techniques. Denoising efficiency is described by PSNR and PSNR-HVS-M metrics. Within hard-thresholding denoising mechanism, DCT-spectrum coefficient statistics are used to characterize images and, subsequently, denoising efficiency for them. Results of denoising efficiency are fitted for such statistics and efficient approximations are obtained. It is shown that the obtained approximations provide high accuracy of prediction of denoising efficiency.
Microstructure and Mechanical Property Change During FSW and GTAW of Al6061 Alloy
NASA Astrophysics Data System (ADS)
Fahimpour, V.; Sadrnezhaad, S. K.; Karimzadeh, F.
2013-05-01
The variation of morphology and mechanical properties of Al6061 automotive aluminum alloy due to friction stir welding (FSW) and gas tungsten arc welding (GTAW) was investigated by optical metallography, scanning electron microscopy, microhardness measurement, X-ray diffraction, tensile testing, and fractography. The center-line dendrite emergence and microhardness reduction in the heat-affected zone were observed in the GTAW process. Although similar microhardness reduction with respect to the base metal was observed in the FSW samples, higher HVs were obtained for the FSW rather than the GTAW process at almost all heat-affected locations. Ultimate tensile strengths of the FSW and the GTAW samples in the transverse direction were ~0.57 and ~0.35 of the base metal, respectively. Post-weld aging improved the strength, but reduced the ductility of the welding.
[Review of visual display system in flight simulator].
Xie, Guang-hui; Wei, Shao-ning
2003-06-01
Visual display system is the key part and plays a very important role in flight simulators and flight training devices. The developing history of visual display system is recalled and the principle and characters of some visual display systems including collimated display systems and back-projected collimated display systems are described. The future directions of visual display systems are analyzed.
Manzanares, William; Biestro, Alberto; Galusso, Federico; Torre, Maria H; Mañay, Nelly; Pittini, Gustavo; Facchin, Gianella; Hardy, Gil
2009-05-01
To confirm the influence of systemic inflammatory response syndrome (SIRS) on selenium (Se) levels and prospectively evaluate the relationship between serum Se concentration [Se], glutathione peroxidase activity [GPx-3] and injury severity in patients at the time of intensive care unit (ICU) admission. Prospective, observational study. Multidisciplinary University Hospital ICU. A total of 36 ICU patients and 23 healthy volunteer subjects (HVS). Healthy volunteer subjects were designated as controls (Group 1). ICU patients were divided into three groups: without SIRS (Group 2); with SIRS (Group 3); with SIRS and multiple organ dysfunction syndrome (MODS) (Group 4). The latter groups had APACHE II scores >15. [GPx-3] and [Se] were determined by standard methods within the first 48 h of admission to ICU. Kruskal-Wallis and Mann-Whitney U test were used for analysis of non-parametric continuous variables. The predictive value of [Se] and [GPx-3] for SIRS was calculated using a receiver operating characteristics (ROC) analysis. In SIRS and MODS patients [GPx-3] and [Se] decreased significantly (P = 0.0001 and P = 0.002, respectively). After ICU admission [GPx-3] and [Se] had a predictive value for SIRS ([GPx-3] sensitivity: 90%, specificity: 86.2% (cut-off value: 0.5 U/mL); [Se]: sensitivity 90%, specificity 72.4% (cut-off value: 60 microg/L). [Se] had predictive value for ICU mortality (P = 0.034). Systemic inflammatory response syndrome and MODS were associated with early decreases in [Se] and [GPx-3]. Low [Se] and [GPx-3] after ICU admission had a predictive value for SIRS, which may aid future selection of patients who could benefit from Se supplementation.
47 CFR 87.483 - Audio visual warning systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Audio visual warning systems. 87.483 Section 87... AVIATION SERVICES Stations in the Radiodetermination Service § 87.483 Audio visual warning systems. An audio visual warning system (AVWS) is a radar-based obstacle avoidance system. AVWS activates...
Hypervelocity stars from young stellar clusters in the Galactic Centre
NASA Astrophysics Data System (ADS)
Fragione, G.; Capuzzo-Dolcetta, R.; Kroupa, P.
2017-05-01
The enormous velocities of the so-called hypervelocity stars (HVSs) derive, likely, from close interactions with massive black holes, binary stars encounters or supernova explosions. In this paper, we investigate the origin of HVSs as consequence of the close interaction between the Milky Way central massive black hole and a passing-by young stellar cluster. We found that both single and binary HVSs may be generated in a burst-like event, as the cluster passes near the orbital pericentre. High-velocity stars will move close to the initial cluster orbital plane and in the direction of the cluster orbital motion at the pericentre. The binary fraction of these HVS jets depends on the primordial binary fraction in the young cluster. The level of initial mass segregation determines the value of the average mass of the ejected stars. Some binary stars will merge, continuing their travel across and out of the Galaxy as blue stragglers.
Phototaxis and the origin of visual eyes
Randel, Nadine
2016-01-01
Vision allows animals to detect spatial differences in environmental light levels. High-resolution image-forming eyes evolved from low-resolution eyes via increases in photoreceptor cell number, improvements in optics and changes in the neural circuits that process spatially resolved photoreceptor input. However, the evolutionary origins of the first low-resolution visual systems have been unclear. We propose that the lowest resolving (two-pixel) visual systems could initially have functioned in visual phototaxis. During visual phototaxis, such elementary visual systems compare light on either side of the body to regulate phototactic turns. Another, even simpler and non-visual strategy is characteristic of helical phototaxis, mediated by sensory–motor eyespots. The recent mapping of the complete neural circuitry (connectome) of an elementary visual system in the larva of the annelid Platynereis dumerilii sheds new light on the possible paths from non-visual to visual phototaxis and to image-forming vision. We outline an evolutionary scenario focusing on the neuronal circuitry to account for these transitions. We also present a comprehensive review of the structure of phototactic eyes in invertebrate larvae and assign them to the non-visual and visual categories. We propose that non-visual systems may have preceded visual phototactic systems in evolution that in turn may have repeatedly served as intermediates during the evolution of image-forming eyes. PMID:26598725
A knowledge based system for scientific data visualization
NASA Technical Reports Server (NTRS)
Senay, Hikmet; Ignatius, Eve
1992-01-01
A knowledge-based system, called visualization tool assistant (VISTA), which was developed to assist scientists in the design of scientific data visualization techniques, is described. The system derives its knowledge from several sources which provide information about data characteristics, visualization primitives, and effective visual perception. The design methodology employed by the system is based on a sequence of transformations which decomposes a data set into a set of data partitions, maps this set of partitions to visualization primitives, and combines these primitives into a composite visualization technique design. Although the primary function of the system is to generate an effective visualization technique design for a given data set by using principles of visual perception the system also allows users to interactively modify the design, and renders the resulting image using a variety of rendering algorithms. The current version of the system primarily supports visualization techniques having applicability in earth and space sciences, although it may easily be extended to include other techniques useful in other disciplines such as computational fluid dynamics, finite-element analysis and medical imaging.
Visualization of Computational Fluid Dynamics
NASA Technical Reports Server (NTRS)
Gerald-Yamasaki, Michael; Hultquist, Jeff; Bryson, Steve; Kenwright, David; Lane, David; Walatka, Pamela; Clucas, Jean; Watson, Velvin; Lasinski, T. A. (Technical Monitor)
1995-01-01
Scientific visualization serves the dual purpose of exploration and exposition of the results of numerical simulations of fluid flow. Along with the basic visualization process which transforms source data into images, there are four additional components to a complete visualization system: Source Data Processing, User Interface and Control, Presentation, and Information Management. The requirements imposed by the desired mode of operation (i.e. real-time, interactive, or batch) and the source data have their effect on each of these visualization system components. The special requirements imposed by the wide variety and size of the source data provided by the numerical simulation of fluid flow presents an enormous challenge to the visualization system designer. We describe the visualization system components including specific visualization techniques and how the mode of operation and source data requirements effect the construction of computational fluid dynamics visualization systems.
Space shuttle visual simulation system design study
NASA Technical Reports Server (NTRS)
1973-01-01
A recommendation and a specification for the visual simulation system design for the space shuttle mission simulator are presented. A recommended visual system is described which most nearly meets the visual design requirements. The cost analysis of the recommended system covering design, development, manufacturing, and installation is reported. Four alternate systems are analyzed.
Chang, Chih-Hao; Lee, Shu-Chuan; Lo, Yih-Shan; Wang, Jiun-Da; Shaw, Jane; Chang, Ban-Yang
2016-01-01
RNA trafficking plays pivotal roles in regulating plant development, gene silencing, and adaptation to environmental stress. Satellite RNAs (satRNAs), parasites of viruses, depend on their helper viruses (HVs) for replication, encapsidation, and efficient spread. However, it remains largely unknown how satRNAs interact with viruses and the cellular machinery to undergo trafficking. Here, we show that the P20 protein of Bamboo mosaic potexvirus satRNA (satBaMV) can functionally complement in trans the systemic trafficking of P20-defective satBaMV in infected Nicotiana benthamiana. The transgene-derived satBaMV, uncoupled from HV replication, was able to move autonomously across a graft union identified by RT-qPCR, RNA gel blot, and in situ RT-PCR analyses. Coimmunoprecipitation experiments revealed that the major nucleolar protein fibrillarin is coprecipitated in the P20 protein complex. Notably, silencing fibrillarin suppressed satBaMV-, but not HV-, phloem-based movement following grafting or coinoculation with HV. Confocal microscopy revealed that the P20 protein colocalized with fibrillarin in the nucleoli and formed punctate structures associated with plasmodesmata. The mobile satBaMV RNA appears to exist as ribonucleoprotein (RNP) complex composed of P20 and fibrillarin, whereas BaMV movement proteins, capsid protein, and BaMV RNA are recruited with HV coinfection. Taken together, our findings provide insight into movement of satBaMV via the fibrillarin-satBaMV-P20 RNP complex in phloem-mediated systemic trafficking. PMID:27702772
Initial spatio-temporal domain expansion of the Modelfest database
NASA Astrophysics Data System (ADS)
Carney, Thom; Mozaffari, Sahar; Sun, Sean; Johnson, Ryan; Shirvastava, Sharona; Shen, Priscilla; Ly, Emma
2013-03-01
The first Modelfest group publication appeared in the SPIE Human Vision and Electronic Imaging conference proceedings in 1999. "One of the group's goals is to develop a public database of test images with threshold data from multiple laboratories for designing and testing HVS (Human Vision Models)." After extended discussions the group selected a set of 45 static images thought to best meet that goal and collected psychophysical detection data which is available on the WEB and presented in the 2000 SPIE conference proceedings. Several groups have used these datasets to test spatial modeling ideas. Further discussions led to the preliminary stimulus specification for extending the database into the temporal domain which was published in the 2002 conference proceeding. After a hiatus of 12 years, some of us have collected spatio-temporal thresholds on an expanded stimulus set of 41 video clips; the original specification included 35 clips. The principal change involved adding one additional spatial pattern beyond the three originally specified. The stimuli consisted of 4 spatial patterns, Gaussian Blob, 4 c/d Gabor patch, 11.3 c/d Gabor patch and a 2D white noise patch. Across conditions the patterns were temporally modulated over a range of approximately 0-25 Hz as well as temporal edge and pulse modulation conditions. The display and data collection specifications were as specified by the Modelfest groups in the 2002 conference proceedings. To date seven subjects have participated in this phase of the data collection effort, one of which also participated in the first phase of Modelfest. Three of the spatio-temporal stimuli were identical to conditions in the original static dataset. Small differences in the thresholds were evident and may point to a stimulus limitation. The temporal CSF peaked between 4 and 8 Hz for the 0 c/d (Gaussian blob) and 4 c/d patterns. The 4 c/d and 11.3 c/d Gabor temporal CSF was low pass while the 0 c/d pattern was band pass. This preliminary expansion of the Modelfest dataset needs the participation of additional laboratories to evaluate the impact of different methods on threshold estimates and increase the subject base. We eagerly await the addition of new data from interested researchers. It remains to be seen how accurately general HVS models will predict thresholds across both Modelfest datasets.
Li, Wenjing; Li, Jianhong; Wang, Zhenchang; Li, Yong; Liu, Zhaohui; Yan, Fei; Xian, Junfang; He, Huiguang
2015-01-01
Previous studies have shown brain reorganizations after early deprivation of auditory sensory. However, changes of grey matter connectivity have not been investigated in prelingually deaf adolescents yet. In the present study, we aimed to investigate changes of grey matter connectivity within and between auditory, language and visual systems in prelingually deaf adolescents. We recruited 16 prelingually deaf adolescents and 16 age-and gender-matched normal controls, and extracted the grey matter volume as the structural characteristic from 14 regions of interest involved in auditory, language or visual processing to investigate the changes of grey matter connectivity within and between auditory, language and visual systems. Sparse inverse covariance estimation (SICE) was utilized to construct grey matter connectivity between these brain regions. The results show that prelingually deaf adolescents present weaker grey matter connectivity within auditory and visual systems, and connectivity between language and visual systems declined. Notably, significantly increased brain connectivity was found between auditory and visual systems in prelingually deaf adolescents. Our results indicate "cross-modal" plasticity after deprivation of the auditory input in prelingually deaf adolescents, especially between auditory and visual systems. Besides, auditory deprivation and visual deficits might affect the connectivity pattern within language and visual systems in prelingually deaf adolescents.
Public health nurse perceptions of Omaha System data visualization.
Lee, Seonah; Kim, Era; Monsen, Karen A
2015-10-01
Electronic health records (EHRs) provide many benefits related to the storage, deployment, and retrieval of large amounts of patient data. However, EHRs have not fully met the need to reuse data for decision making on follow-up care plans. Visualization offers new ways to present health data, especially in EHRs. Well-designed data visualization allows clinicians to communicate information efficiently and effectively, contributing to improved interpretation of clinical data and better patient care monitoring and decision making. Public health nurse (PHN) perceptions of Omaha System data visualization prototypes for use in EHRs have not been evaluated. To visualize PHN-generated Omaha System data and assess PHN perceptions regarding the visual validity, helpfulness, usefulness, and importance of the visualizations, including interactive functionality. Time-oriented visualization for problems and outcomes and Matrix visualization for problems and interventions were developed using PHN-generated Omaha System data to help PHNs consume data and plan care at the point of care. Eleven PHNs evaluated prototype visualizations. Overall PHNs response to visualizations was positive, and feedback for improvement was provided. This study demonstrated the potential for using visualization techniques within EHRs to summarize Omaha System patient data for clinicians. Further research is needed to improve and refine these visualizations and assess the potential to incorporate visualizations within clinical EHRs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Foyle, David C.; Kaiser, Mary K.; Johnson, Walter W.
1992-01-01
This paper reviews some of the sources of visual information that are available in the out-the-window scene and describes how these visual cues are important for routine pilotage and training, as well as the development of simulator visual systems and enhanced or synthetic vision systems for aircraft cockpits. It is shown how these visual cues may change or disappear under environmental or sensor conditions, and how the visual scene can be augmented by advanced displays to capitalize on the pilot's excellent ability to extract visual information from the visual scene.
Technical note: real-time web-based wireless visual guidance system for radiotherapy.
Lee, Danny; Kim, Siyong; Palta, Jatinder R; Kim, Taeho
2017-06-01
Describe a Web-based wireless visual guidance system that mitigates issues associated with hard-wired audio-visual aided patient interactive motion management systems that are cumbersome to use in routine clinical practice. Web-based wireless visual display duplicates an existing visual display of a respiratory-motion management system for visual guidance. The visual display of the existing system is sent to legacy Web clients over a private wireless network, thereby allowing a wireless setting for real-time visual guidance. In this study, active breathing coordinator (ABC) trace was used as an input for visual display, which captured and transmitted to Web clients. Virtual reality goggles require two (left and right eye view) images for visual display. We investigated the performance of Web-based wireless visual guidance by quantifying (1) the network latency of visual displays between an ABC computer display and Web clients of a laptop, an iPad mini 2 and an iPhone 6, and (2) the frame rate of visual display on the Web clients in frames per second (fps). The network latency of visual display between the ABC computer and Web clients was about 100 ms and the frame rate was 14.0 fps (laptop), 9.2 fps (iPad mini 2) and 11.2 fps (iPhone 6). In addition, visual display for virtual reality goggles was successfully shown on the iPhone 6 with 100 ms and 11.2 fps. A high network security was maintained by utilizing the private network configuration. This study demonstrated that a Web-based wireless visual guidance can be a promising technique for clinical motion management systems, which require real-time visual display of their outputs. Based on the results of this study, our approach has the potential to reduce clutter associated with wired-systems, reduce space requirements, and extend the use of medical devices from static usage to interactive and dynamic usage in a radiotherapy treatment vault.
NASA Technical Reports Server (NTRS)
Haines, R. F.; Fitzgerald, J. W.; Rositano, S. A. (Inventor)
1976-01-01
An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location including a projection system for displaying to a patient a series of visual stimuli. A response switch enables him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system thereby provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made.
Creating visual explanations improves learning.
Bobek, Eliza; Tversky, Barbara
2016-01-01
Many topics in science are notoriously difficult for students to learn. Mechanisms and processes outside student experience present particular challenges. While instruction typically involves visualizations, students usually explain in words. Because visual explanations can show parts and processes of complex systems directly, creating them should have benefits beyond creating verbal explanations. We compared learning from creating visual or verbal explanations for two STEM domains, a mechanical system (bicycle pump) and a chemical system (bonding). Both kinds of explanations were analyzed for content and learning assess by a post-test. For the mechanical system, creating a visual explanation increased understanding particularly for participants of low spatial ability. For the chemical system, creating both visual and verbal explanations improved learning without new teaching. Creating a visual explanation was superior and benefitted participants of both high and low spatial ability. Visual explanations often included crucial yet invisible features. The greater effectiveness of visual explanations appears attributable to the checks they provide for completeness and coherence as well as to their roles as platforms for inference. The benefits should generalize to other domains like the social sciences, history, and archeology where important information can be visualized. Together, the findings provide support for the use of learner-generated visual explanations as a powerful learning tool.
NASA Technical Reports Server (NTRS)
Haines, R. F.; Fitzgerald, J. W.; Rositano, S. A. (Inventor)
1973-01-01
An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location is described. The apparatus includes a projection system for displaying to a patient a series of visual stimuli, a response switch enabling him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made.
Neuron analysis of visual perception
NASA Technical Reports Server (NTRS)
Chow, K. L.
1980-01-01
The receptive fields of single cells in the visual system of cat and squirrel monkey were studied investigating the vestibular input affecting the cells, and the cell's responses during visual discrimination learning process. The receptive field characteristics of the rabbit visual system, its normal development, its abnormal development following visual deprivation, and on the structural and functional re-organization of the visual system following neo-natal and prenatal surgery were also studied. The results of each individual part of each investigation are detailed.
Interactive Learning System "VisMis" for Scientific Visualization Course
ERIC Educational Resources Information Center
Zhu, Xiaoming; Sun, Bo; Luo, Yanlin
2018-01-01
Now visualization courses have been taught at universities around the world. Keeping students motivated and actively engaged in this course can be a challenging task. In this paper we introduce our developed interactive learning system called VisMis (Visualization and Multi-modal Interaction System) for postgraduate scientific visualization course…
TOPICAL REVIEW: Prosthetic interfaces with the visual system: biological issues
NASA Astrophysics Data System (ADS)
Cohen, Ethan D.
2007-06-01
The design of effective visual prostheses for the blind represents a challenge for biomedical engineers and neuroscientists. Significant progress has been made in the miniaturization and processing power of prosthesis electronics; however development lags in the design and construction of effective machine brain interfaces with visual system neurons. This review summarizes what has been learned about stimulating neurons in the human and primate retina, lateral geniculate nucleus and visual cortex. Each level of the visual system presents unique challenges for neural interface design. Blind patients with the retinal degenerative disease retinitis pigmentosa (RP) are a common population in clinical trials of visual prostheses. The visual performance abilities of normals and RP patients are compared. To generate pattern vision in blind patients, the visual prosthetic interface must effectively stimulate the retinotopically organized neurons in the central visual field to elicit patterned visual percepts. The development of more biologically compatible methods of stimulating visual system neurons is critical to the development of finer spatial percepts. Prosthesis electrode arrays need to adapt to different optimal stimulus locations, stimulus patterns, and patient disease states.
NASA Technical Reports Server (NTRS)
1985-01-01
A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.
Urlic, Iris; Verzak, Željko; Vranic, Dubravka Negovetic
2016-01-01
Aim The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC) with near visual acuity of those using the Galilean telescope system (VGA2) with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. Methods The study included 46 dentists (visual acuity 1.0 without correction). A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) without correction at a distance of 300-400 mm (VSC); 2) with Galilean loupes with magnification of x2.5, focal length of 350mm. Results The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001). Conclusion If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC). PMID:27847397
Urlic, Iris; Verzak, Željko; Vranic, Dubravka Negovetic
2016-09-01
The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC) with near visual acuity of those using the Galilean telescope system (VGA2) with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. The study included 46 dentists (visual acuity 1.0 without correction). A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) without correction at a distance of 300-400 mm (VSC); 2) with Galilean loupes with magnification of x2.5, focal length of 350mm. The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001). If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC).
A proposed intracortical visual prosthesis image processing system.
Srivastava, N R; Troyk, P
2005-01-01
It has been a goal of neuroprosthesis researchers to develop a system, which could provide artifical vision to a large population of individuals with blindness. It has been demonstrated by earlier researches that stimulating the visual cortex area electrically can evoke spatial visual percepts, i.e. phosphenes. The goal of visual cortex prosthesis is to stimulate the visual cortex area and generate a visual perception in real time to restore vision. Even though the normal working of the visual system is not been completely understood, the existing knowledge has inspired research groups to develop strategies to develop visual cortex prosthesis which can help blind patients in their daily activities. A major limitation in this work is the development of an image proceessing system for converting an electronic image, as captured by a camera, into a real-time data stream for stimulation of the implanted electrodes. This paper proposes a system, which will capture the image using a camera and use a dedicated hardware real time image processor to deliver electrical pulses to intracortical electrodes. This system has to be flexible enough to adapt to individual patients and to various strategies of image reconstruction. Here we consider a preliminary architecture for this system.
Visualizing Terrestrial and Aquatic Systems in 3D
The need for better visualization tools for environmental science is well documented, and the Visualization for Terrestrial and Aquatic Systems project (VISTAS) aims to both help scientists produce effective environmental science visualizations and to determine which visualizatio...
A hierarchical, retinotopic proto-organization of the primate visual system at birth
Arcaro, Michael J; Livingstone, Margaret S
2017-01-01
The adult primate visual system comprises a series of hierarchically organized areas. Each cortical area contains a topographic map of visual space, with different areas extracting different kinds of information from the retinal input. Here we asked to what extent the newborn visual system resembles the adult organization. We find that hierarchical, topographic organization is present at birth and therefore constitutes a proto-organization for the entire primate visual system. Even within inferior temporal cortex, this proto-organization was already present, prior to the emergence of category selectivity (e.g., faces or scenes). We propose that this topographic organization provides the scaffolding for the subsequent development of visual cortex that commences at the onset of visual experience DOI: http://dx.doi.org/10.7554/eLife.26196.001 PMID:28671063
Kang, Youn-Ah; Stasko, J
2012-12-01
While the formal evaluation of systems in visual analytics is still relatively uncommon, particularly rare are case studies of prolonged system use by domain analysts working with their own data. Conducting case studies can be challenging, but it can be a particularly effective way to examine whether visual analytics systems are truly helping expert users to accomplish their goals. We studied the use of a visual analytics system for sensemaking tasks on documents by six analysts from a variety of domains. We describe their application of the system along with the benefits, issues, and problems that we uncovered. Findings from the studies identify features that visual analytics systems should emphasize as well as missing capabilities that should be addressed. These findings inform design implications for future systems.
Space shuttle visual simulation system design study
NASA Technical Reports Server (NTRS)
1973-01-01
The current and near-future state-of-the-art in visual simulation equipment technology is related to the requirements of the space shuttle visual system. Image source, image sensing, and displays are analyzed on a subsystem basis, and the principal conclusions are used in the formulation of a recommended baseline visual system. Perceptibility and visibility are also analyzed.
Systems and Methods for Data Visualization Using Three-Dimensional Displays
NASA Technical Reports Server (NTRS)
Davidoff, Scott (Inventor); Djorgovski, Stanislav G. (Inventor); Estrada, Vicente (Inventor); Donalek, Ciro (Inventor)
2017-01-01
Data visualization systems and methods for generating 3D visualizations of a multidimensional data space are described. In one embodiment a 3D data visualization application directs a processing system to: load a set of multidimensional data points into a visualization table; create representations of a set of 3D objects corresponding to the set of data points; receive mappings of data dimensions to visualization attributes; determine the visualization attributes of the set of 3D objects based upon the selected mappings of data dimensions to 3D object attributes; update a visibility dimension in the visualization table for each of the plurality of 3D object to reflect the visibility of each 3D object based upon the selected mappings of data dimensions to visualization attributes; and interactively render 3D data visualizations of the 3D objects within the virtual space from viewpoints determined based upon received user input.
Mechanisms Underlying Development of Visual Maps and Receptive Fields
Huberman, Andrew D.; Feller, Marla B.; Chapman, Barbara
2008-01-01
Patterns of synaptic connections in the visual system are remarkably precise. These connections dictate the receptive field properties of individual visual neurons and ultimately determine the quality of visual perception. Spontaneous neural activity is necessary for the development of various receptive field properties and visual feature maps. In recent years, attention has shifted to understanding the mechanisms by which spontaneous activity in the developing retina, lateral geniculate nucleus, and visual cortex instruct the axonal and dendritic refinements that give rise to orderly connections in the visual system. Axon guidance cues and a growing list of other molecules, including immune system factors, have also recently been implicated in visual circuit wiring. A major goal now is to determine how these molecules cooperate with spontaneous and visually evoked activity to give rise to the circuits underlying precise receptive field tuning and orderly visual maps. PMID:18558864
Feng, Haibo; Dong, Dinghui; Ma, Tengfei; Zhuang, Jinlei; Fu, Yili; Lv, Yi; Li, Liyi
2017-12-01
Surgical robot systems which can significantly improve surgical procedures have been widely used in laparoendoscopic single-site surgery (LESS). For a relative complex surgical procedure, the development of an in vivo visual robot system for LESS can effectively improve the visualization for surgical robot systems. In this work, an in vivo visual robot system with a new mechanism for LESS was investigated. A finite element method (FEM) analysis was carried out to ensure the safety of the in vivo visual robot during the movement, which was the most important concern for surgical purposes. A master-slave control strategy was adopted, in which the control model was established by off-line experiments. The in vivo visual robot system was verified by using a phantom box. The experiment results show that the robot system can successfully realize the expected functionalities and meet the demands of LESS. The experiment results indicate that the in vivo visual robot with high manipulability has great potential in clinical application. Copyright © 2017 John Wiley & Sons, Ltd.
Conceptual design study for a teleoperator visual system, phase 2
NASA Technical Reports Server (NTRS)
Grant, C.; Meirick, R.; Polhemus, C.; Spencer, R.; Swain, D.; Twell, R.
1973-01-01
An analysis of the concept for the hybrid stereo-monoscopic television visual system is reported. The visual concept is described along with the following subsystems: illumination, deployment/articulation, telecommunications, visual displays, and the controls and display station.
Advanced in Visualization of 3D Time-Dependent CFD Solutions
NASA Technical Reports Server (NTRS)
Lane, David A.; Lasinski, T. A. (Technical Monitor)
1995-01-01
Numerical simulations of complex 3D time-dependent (unsteady) flows are becoming increasingly feasible because of the progress in computing systems. Unfortunately, many existing flow visualization systems were developed for time-independent (steady) solutions and do not adequately depict solutions from unsteady flow simulations. Furthermore, most systems only handle one time step of the solutions individually and do not consider the time-dependent nature of the solutions. For example, instantaneous streamlines are computed by tracking the particles using one time step of the solution. However, for streaklines and timelines, particles need to be tracked through all time steps. Streaklines can reveal quite different information about the flow than those revealed by instantaneous streamlines. Comparisons of instantaneous streamlines with dynamic streaklines are shown. For a complex 3D flow simulation, it is common to generate a grid system with several millions of grid points and to have tens of thousands of time steps. The disk requirement for storing the flow data can easily be tens of gigabytes. Visualizing solutions of this magnitude is a challenging problem with today's computer hardware technology. Even interactive visualization of one time step of the flow data can be a problem for some existing flow visualization systems because of the size of the grid. Current approaches for visualizing complex 3D time-dependent CFD solutions are described. The flow visualization system developed at NASA Ames Research Center to compute time-dependent particle traces from unsteady CFD solutions is described. The system computes particle traces (streaklines) by integrating through the time steps. This system has been used by several NASA scientists to visualize their CFD time-dependent solutions. The flow visualization capabilities of this system are described, and visualization results are shown.
DVV: a taxonomy for mixed reality visualization in image guided surgery.
Kersten-Oertel, Marta; Jannin, Pierre; Collins, D Louis
2012-02-01
Mixed reality visualizations are increasingly studied for use in image guided surgery (IGS) systems, yet few mixed reality systems have been introduced for daily use into the operating room (OR). This may be the result of several factors: the systems are developed from a technical perspective, are rarely evaluated in the field, and/or lack consideration of the end user and the constraints of the OR. We introduce the Data, Visualization processing, View (DVV) taxonomy which defines each of the major components required to implement a mixed reality IGS system. We propose that these components be considered and used as validation criteria for introducing a mixed reality IGS system into the OR. A taxonomy of IGS visualization systems is a step toward developing a common language that will help developers and end users discuss and understand the constituents of a mixed reality visualization system, facilitating a greater presence of future systems in the OR. We evaluate the DVV taxonomy based on its goodness of fit and completeness. We demonstrate the utility of the DVV taxonomy by classifying 17 state-of-the-art research papers in the domain of mixed reality visualization IGS systems. Our classification shows that few IGS visualization systems' components have been validated and even fewer are evaluated.
The SCHEIE Visual Field Grading System
Sankar, Prithvi S.; O’Keefe, Laura; Choi, Daniel; Salowe, Rebecca; Miller-Ellis, Eydie; Lehman, Amanda; Addis, Victoria; Ramakrishnan, Meera; Natesh, Vikas; Whitehead, Gideon; Khachatryan, Naira; O’Brien, Joan
2017-01-01
Objective No method of grading visual field (VF) defects has been widely accepted throughout the glaucoma community. The SCHEIE (Systematic Classification of Humphrey visual fields-Easy Interpretation and Evaluation) grading system for glaucomatous visual fields was created to convey qualitative and quantitative information regarding visual field defects in an objective, reproducible, and easily applicable manner for research purposes. Methods The SCHEIE grading system is composed of a qualitative and quantitative score. The qualitative score consists of designation in one or more of the following categories: normal, central scotoma, paracentral scotoma, paracentral crescent, temporal quadrant, nasal quadrant, peripheral arcuate defect, expansive arcuate, or altitudinal defect. The quantitative component incorporates the Humphrey visual field index (VFI), location of visual defects for superior and inferior hemifields, and blind spot involvement. Accuracy and speed at grading using the qualitative and quantitative components was calculated for non-physician graders. Results Graders had a median accuracy of 96.67% for their qualitative scores and a median accuracy of 98.75% for their quantitative scores. Graders took a mean of 56 seconds per visual field to assign a qualitative score and 20 seconds per visual field to assign a quantitative score. Conclusion The SCHEIE grading system is a reproducible tool that combines qualitative and quantitative measurements to grade glaucomatous visual field defects. The system aims to standardize clinical staging and to make specific visual field defects more easily identifiable. Specific patterns of visual field loss may also be associated with genetic variants in future genetic analysis. PMID:28932621
[Three-dimensional morphological modeling and visualization of wheat root system].
Tan, Feng; Tang, Liang; Hu, Jun-Cheng; Jiang, Hai-Yan; Cao, Wei-Xing; Zhu, Yan
2011-01-01
Crop three-dimensional (3D) morphological modeling and visualization is an important part of digital plant study. This paper aimed to develop a 3D morphological model of wheat root system based on the parameters of wheat root morphological features, and to realize the visualization of wheat root growth. According to the framework of visualization technology for wheat root growth, a 3D visualization model of wheat root axis, including root axis growth model, branch geometric model, and root axis curve model, was developed firstly. Then, by integrating root topology, the corresponding pixel was determined, and the whole wheat root system was three-dimensionally re-constructed by using the morphological feature parameters in the root morphological model. Finally, based on the platform of OpenGL, and by integrating the technologies of texture mapping, lighting rendering, and collision detection, the 3D visualization of wheat root growth was realized. The 3D output of wheat root system from the model was vivid, which could realize the 3D root system visualization of different wheat cultivars under different water regimes and nitrogen application rates. This study could lay a technical foundation for further development of an integral visualization system of wheat plant.
Sulfur chemistry in dense interstellar clouds
NASA Technical Reports Server (NTRS)
Prasad, S. S.; Huntress, W. T., Jr.
1982-01-01
A model is presented for the gas phase chemistry of molecules containing sulfur in dense interstellar clouds. The sulfur chemistry is different from that used in previous models as a result of an extensive search of the recent literature and the availability of new laboratory data. The changes have a significant effect on the calculated abundance of sulfur compounds. The linked chemistry of sulfur and oxygen in the present model requires a severe depletion of sulfur and low fractional abundances of both O and O2 in the dense clouds. In contrast, the high abundance of SO and the low abundance of CS relative to SO in the HVS in the KL may indicate an oxygen-rich, high temperature environment compared to OMC-1. The formation of S-H bonds is slow because of the absence of radiative association between S(+) and H2. The present model underestimates the abundance of H2S unless a radiative association reaction between HS(+) and H2 is postulated.
Ancient inland human dispersals from Myanmar into interior East Asia since the Late Pleistocene.
Li, Yu-Chun; Wang, Hua-Wei; Tian, Jiao-Yang; Liu, Li-Na; Yang, Li-Qin; Zhu, Chun-Ling; Wu, Shi-Fang; Kong, Qing-Peng; Zhang, Ya-Ping
2015-03-26
Given the existence of plenty of river valleys connecting Southeast and East Asia, it is possible that some inland route(s) might have been adopted by the initial settlers to migrate into the interior of East Asia. Here we analyzed mitochondrial DNA (mtDNA) HVS variants of 845 newly collected individuals from 14 Myanmar populations and 5,907 published individuals from 115 populations from Myanmar and its surroundings. Enrichment of basal lineages with the highest genetic diversity in Myanmar suggests that Myanmar was likely one of the differentiation centers of the early modern humans. Intriguingly, some haplogroups were shared merely between Myanmar and southwestern China, hinting certain genetic connection between both regions. Further analyses revealed that such connection was in fact attributed to both recent gene flow and certain ancient dispersals from Myanmar to southwestern China during 25-10 kya, suggesting that, besides the coastal route, the early modern humans also adopted an inland dispersal route to populate the interior of East Asia.
Wilson, Jamie L; Saint-Louis, Vertus; Auguste, Jensen O; Jackson, Bruce A
2012-11-01
Very little genetic data exist on Haitians, an estimated 1.2 million of whom, not including illegal immigrants, reside in the United States. The absence of genetic data on a population of this size reduces the discriminatory power of criminal and missing-person DNA databases in the United States and Caribbean. We present a forensic population study that provides the first genetic data set for Haiti. This study uses hypervariable segment one (HVS-1) mitochondrial DNA (mtDNA) nucleotide sequences from 291 subjects primarily from rural areas of northern and southern Haiti, where admixture would be minimal. Our results showed that the African maternal genetic component of Haitians had slightly higher West-Central African admixture than African-Americans and Dominicans, but considerably less than Afro-Brazilians. These results lay the foundation for further forensic genetics studies in the Haitian population and serve as a model for forensic mtDNA identification of individuals in other isolated or rural communities. © 2012 American Academy of Forensic Sciences.
ON THE BIOMECHANICS OF HEART VALVE FUNCTION
Sacks, Michael S.; Merryman, W. David; Schmidt, David E.
2009-01-01
Heart valves (HVs) are fluidic control components of the heart that ensure unidirectional blood flow during the cardiac cycle. However, this description does not adequately describe the biomechanical ramifications of their function in that their mechanics are multi-modal. Moreover, they must replicate their cyclic function over an entire lifetime, with an estimated total functional demand of least 3×109 cycles. The focus of the present review is on the functional biomechanics of heart valves. Thus, the focus of the present review is on functional biomechanics, referring primarily to biosolid as well as several key biofluid mechanical aspects underlying heart valve physiological function. Specifically, we refer to the mechanical behaviors of the extra-cellular matrix structural proteins, underlying cellular function, and their integrated relation to the major aspects of valvular hemodynamic function. While we focus on the work from the author’s laboratories, relevant works of other investigators have been included whenever appropriate. We conclude with a summary of important future trends. PMID:19540499
A new method of Quickbird own image fusion
NASA Astrophysics Data System (ADS)
Han, Ying; Jiang, Hong; Zhang, Xiuying
2009-10-01
With the rapid development of remote sensing technology, the means of accessing to remote sensing data become increasingly abundant, thus the same area can form a large number of multi-temporal, different resolution image sequence. At present, the fusion methods are mainly: HPF, IHS transform method, PCA method, Brovey, Mallat algorithm and wavelet transform and so on. There exists a serious distortion of the spectrums in the IHS transform, Mallat algorithm omits low-frequency information of the high spatial resolution images, the integration results of which has obvious blocking effects. Wavelet multi-scale decomposition for different sizes, the directions, details and the edges can have achieved very good results, but different fusion rules and algorithms can achieve different effects. This article takes the Quickbird own image fusion as an example, basing on wavelet transform and HVS, wavelet transform and IHS integration. The result shows that the former better. This paper introduces the correlation coefficient, the relative average spectral error index and usual index to evaluate the quality of image.
Effects of multiple firings on the microstructure of zirconia and veneering ceramics.
Alkurt, Murat; Yeşil Duymus, Zeynep; Gundogdu, Mustafa
2016-01-01
The aim of study was to evaluate the effects of multiple firings on the microstructures of zirconia and two ceramics. Vita VM9 (VMZ) and Cerabien ZR (C-Z) ceramics on a zirconia framework and zirconia without veneering ceramic (WO-Z) were evaluated. Firing methods included firing two, five, and ten times (n=10). The effects of multiple firings on the surface hardness of the materials were evaluated using a Vickers hardness (HV) tester. Data were analyzed by two-way ANOVA and Tukey's test (α=0.05). After firing five and ten times, the hardness of VM-Z and C-Z increased significantly (p<0.001). The HVs of the Cerabien ZR and Vita VM9 veneering ceramics were similar (p>0.05). In the XRD analysis, zirconia had similar tetragonal (t)-monoclinic (m) phase transformations of Y-TZP after the different firing times. Clinically, multiple firings did not affect the microstructure of zirconia, but the structures of the two ceramics were affected.
Visualizing Terrestrial and Aquatic Systems in 3D - in IEEE VisWeek 2014
The need for better visualization tools for environmental science is well documented, and the Visualization for Terrestrial and Aquatic Systems project (VISTAS) aims to both help scientists produce effective environmental science visualizations and to determine which visualizatio...
40 CFR 202.22 - Visual exhaust system inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Visual exhaust system inspection. 202... Standards § 202.22 Visual exhaust system inspection. No motor carrier subject to these regulations shall operate any motor vehicle of a type to which this regulation is applicable unless the exhaust system of...
40 CFR 202.22 - Visual exhaust system inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Visual exhaust system inspection. 202... Standards § 202.22 Visual exhaust system inspection. No motor carrier subject to these regulations shall operate any motor vehicle of a type to which this regulation is applicable unless the exhaust system of...
40 CFR 202.22 - Visual exhaust system inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Visual exhaust system inspection. 202... Standards § 202.22 Visual exhaust system inspection. No motor carrier subject to these regulations shall operate any motor vehicle of a type to which this regulation is applicable unless the exhaust system of...
A new system for quantitative evaluation of infant gaze capabilities in a wide visual field.
Pratesi, Andrea; Cecchi, Francesca; Beani, Elena; Sgandurra, Giuseppina; Cioni, Giovanni; Laschi, Cecilia; Dario, Paolo
2015-09-07
The visual assessment of infants poses specific challenges: many techniques that are used on adults are based on the patient's response, and are not suitable for infants. Significant advances in the eye-tracking have made this assessment of infant visual capabilities easier, however, eye-tracking still requires the subject's collaboration, in most cases and thus limiting the application in infant research. Moreover, there is a lack of transferability to clinical practice, and thus it emerges the need for a new tool to measure the paradigms and explore the most common visual competences in a wide visual field. This work presents the design, development and preliminary testing of a new system for measuring infant's gaze in the wide visual field called CareToy C: CareToy for Clinics. The system is based on a commercial eye tracker (SmartEye) with six cameras running at 60 Hz, suitable for measuring an infant's gaze. In order to stimulate the infant visually and audibly, a mechanical structure has been designed to support five speakers and five screens at a specific distance (60 cm) and angle: one in the centre, two on the right-hand side and two on the left (at 30° and 60° respectively). Different tasks have been designed in order to evaluate the system capability to assess the infant's gaze movements during different conditions (such as gap, overlap or audio-visual paradigms). Nine healthy infants aged 4-10 months were assessed as they performed the visual tasks at random. We developed a system able to measure infant's gaze in a wide visual field covering a total visual range of ±60° from the centre with an intermediate evaluation at ±30°. Moreover, the same system, thanks to different integrated software, was able to provide different visual paradigms (as gap, overlap and audio-visual) assessing and comparing different visual and multisensory sub-competencies. The proposed system endowed the integration of a commercial eye-tracker into a purposive setup in a smart and innovative way. The proposed system is suitable for measuring and evaluating infant's gaze capabilities in a wide visual field, in order to provide quantitative data that can enrich the clinical assessment.
Defining the cortical visual systems: "what", "where", and "how"
NASA Technical Reports Server (NTRS)
Creem, S. H.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)
2001-01-01
The visual system historically has been defined as consisting of at least two broad subsystems subserving object and spatial vision. These visual processing streams have been organized both structurally as two distinct pathways in the brain, and functionally for the types of tasks that they mediate. The classic definition by Ungerleider and Mishkin labeled a ventral "what" stream to process object information and a dorsal "where" stream to process spatial information. More recently, Goodale and Milner redefined the two visual systems with a focus on the different ways in which visual information is transformed for different goals. They relabeled the dorsal stream as a "how" system for transforming visual information using an egocentric frame of reference in preparation for direct action. This paper reviews recent research from psychophysics, neurophysiology, neuropsychology and neuroimaging to define the roles of the ventral and dorsal visual processing streams. We discuss a possible solution that allows for both "where" and "how" systems that are functionally and structurally organized within the posterior parietal lobe.
The Application of Current User Interface Technology to Interactive Wargaming Systems.
1987-09-01
components is essential to the Macintosh interface. Apple states that "Consistent visual communication is very powerful in delivering complex messages...interface. A visual interface uses visual objects as the basis of communication. "A visual communication object is some combination S. of text and...graphics used for communication under a system of inter- pretation, or visual language." The benefit of visual communication is V 45 "When humans are faced
Wiebrands, Michael; Malajczuk, Chris J; Woods, Andrew J; Rohl, Andrew L; Mancera, Ricardo L
2018-06-21
Molecular graphics systems are visualization tools which, upon integration into a 3D immersive environment, provide a unique virtual reality experience for research and teaching of biomolecular structure, function and interactions. We have developed a molecular structure and dynamics application, the Molecular Dynamics Visualization tool, that uses the Unity game engine combined with large scale, multi-user, stereoscopic visualization systems to deliver an immersive display experience, particularly with a large cylindrical projection display. The application is structured to separate the biomolecular modeling and visualization systems. The biomolecular model loading and analysis system was developed as a stand-alone C# library and provides the foundation for the custom visualization system built in Unity. All visual models displayed within the tool are generated using Unity-based procedural mesh building routines. A 3D user interface was built to allow seamless dynamic interaction with the model while being viewed in 3D space. Biomolecular structure analysis and display capabilities are exemplified with a range of complex systems involving cell membranes, protein folding and lipid droplets.
ERIC Educational Resources Information Center
Ravenscroft, John; Blaikie, Andrew; Macewen, Caroline; O'Hare, Anne; Creswell, Lyn; Dutton, Gordon N.
2008-01-01
The purpose of this study is to pilot a new notification system for children with visual impairment (VI) and describe the initial summary findings. A system of notification of children in Scotland with VI was established. Information concerning this system was distributed to professionals working with visually impaired children to forward to…
VAST Challenge 2016: Streaming Visual Analytics
2016-10-25
understand rapidly evolving situations. To support such tasks, visual analytics solutions must move well beyond systems that simply provide real-time...received. Mini-Challenge 1: Design Challenge Mini-Challenge 1 focused on systems to support security and operational analytics at the Euybia...Challenge 1 was to solicit novel approaches for streaming visual analytics that push the boundaries for what constitutes a visual analytics system , and to
A vision fusion treatment system based on ATtiny26L
NASA Astrophysics Data System (ADS)
Zhang, Xiaoqing; Zhang, Chunxi; Wang, Jiqiang
2006-11-01
Vision fusion treatment is an important and effective project to strabismus children. The vision fusion treatment system based on the principle for eyeballs to follow the moving visual survey pole is put forward first. In this system the original position of visual survey pole is about 35 centimeters far from patient's face before its moving to the middle position between the two eyeballs. The eyeballs of patient will follow the movement of the visual survey pole. When they can't follow, one or two eyeballs will turn to other position other than the visual survey pole. This displacement is recorded every time. A popular single chip microcomputer ATtiny26L is used in this system, which has a PWM output signal to control visual survey pole to move with continuously variable speed. The movement of visual survey pole accords to the modulating law of eyeballs to follow visual survey pole.
Blindsight and Unconscious Vision: What They Teach Us about the Human Visual System
Ajina, Sara; Bridge, Holly
2017-01-01
Damage to the primary visual cortex removes the major input from the eyes to the brain, causing significant visual loss as patients are unable to perceive the side of the world contralateral to the damage. Some patients, however, retain the ability to detect visual information within this blind region; this is known as blindsight. By studying the visual pathways that underlie this residual vision in patients, we can uncover additional aspects of the human visual system that likely contribute to normal visual function but cannot be revealed under physiological conditions. In this review, we discuss the residual abilities and neural activity that have been described in blindsight and the implications of these findings for understanding the intact system. PMID:27777337
A Unified Air-Sea Visualization System: Survey on Gridding Structures
NASA Technical Reports Server (NTRS)
Anand, Harsh; Moorhead, Robert
1995-01-01
The goal is to develop a Unified Air-Sea Visualization System (UASVS) to enable the rapid fusion of observational, archival, and model data for verification and analysis. To design and develop UASVS, modelers were polled to determine the gridding structures and visualization systems used, and their needs with respect to visual analysis. A basic UASVS requirement is to allow a modeler to explore multiple data sets within a single environment, or to interpolate multiple datasets onto one unified grid. From this survey, the UASVS should be able to visualize 3D scalar/vector fields; render isosurfaces; visualize arbitrary slices of the 3D data; visualize data defined on spectral element grids with the minimum number of interpolation stages; render contours; produce 3D vector plots and streamlines; provide unified visualization of satellite images, observations and model output overlays; display the visualization on a projection of the users choice; implement functions so the user can derive diagnostic values; animate the data to see the time-evolution; animate ocean and atmosphere at different rates; store the record of cursor movement, smooth the path, and animate a window around the moving path; repeatedly start and stop the visual time-stepping; generate VHS tape animations; work on a variety of workstations; and allow visualization across clusters of workstations and scalable high performance computer systems.
NASA Technical Reports Server (NTRS)
Parris, B. L.; Cook, A. M.
1978-01-01
Data are presented that show the effects of visual and motion during cueing on pilot performance during takeoffs with engine failures. Four groups of USAF pilots flew a simulated KC-135 using four different cueing systems. The most basic of these systems was of the instrument-only type. Visual scene simulation and/or motion simulation was added to produce the other systems. Learning curves, mean performance, and subjective data are examined. The results show that the addition of visual cueing results in significant improvement in pilot performance, but the combined use of visual and motion cueing results in far better performance.
A survey of visualization systems for network security.
Shiravi, Hadi; Shiravi, Ali; Ghorbani, Ali A
2012-08-01
Security Visualization is a very young term. It expresses the idea that common visualization techniques have been designed for use cases that are not supportive of security-related data, demanding novel techniques fine tuned for the purpose of thorough analysis. Significant amount of work has been published in this area, but little work has been done to study this emerging visualization discipline. We offer a comprehensive review of network security visualization and provide a taxonomy in the form of five use-case classes encompassing nearly all recent works in this area. We outline the incorporated visualization techniques and data sources and provide an informative table to display our findings. From the analysis of these systems, we examine issues and concerns regarding network security visualization and provide guidelines and directions for future researchers and visual system developers.
Interaction Junk: User Interaction-Based Evaluation of Visual Analytic Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endert, Alexander; North, Chris
2012-10-14
With the growing need for visualization to aid users in understanding large, complex datasets, the ability for users to interact and explore these datasets is critical. As visual analytic systems have advanced to leverage powerful computational models and data analytics capabilities, the modes by which users engage and interact with the information are limited. Often, users are taxed with directly manipulating parameters of these models through traditional GUIs (e.g., using sliders to directly manipulate the value of a parameter). However, the purpose of user interaction in visual analytic systems is to enable visual data exploration – where users can focusmore » on their task, as opposed to the tool or system. As a result, users can engage freely in data exploration and decision-making, for the purpose of gaining insight. In this position paper, we discuss how evaluating visual analytic systems can be approached through user interaction analysis, where the goal is to minimize the cognitive translation between the visual metaphor and the mode of interaction (i.e., reducing the “Interactionjunk”). We motivate this concept through a discussion of traditional GUIs used in visual analytics for direct manipulation of model parameters, and the importance of designing interactions the support visual data exploration.« less
NASA Technical Reports Server (NTRS)
Berchem, J.; Raeder, J.; Walker, R. J.; Ashour-Abdalla, M.
1995-01-01
We report on the development of an interactive system for visualizing and analyzing numerical simulation results. This system is based on visualization modules which use the Application Visualization System (AVS) and the NCAR graphics packages. Examples from recent simulations are presented to illustrate how these modules can be used for displaying and manipulating simulation results to facilitate their comparison with phenomenological model results and observations.
Art, Illusion and the Visual System.
ERIC Educational Resources Information Center
Livingstone, Margaret S.
1988-01-01
Describes the three part system of human vision. Explores the anatomical arrangement of the vision system from the eyes to the brain. Traces the path of various visual signals to their interpretations by the brain. Discusses human visual perception and its implications in art and design. (CW)
High-Performance Computing and Visualization | Energy Systems Integration
Facility | NREL High-Performance Computing and Visualization High-Performance Computing and Visualization High-performance computing (HPC) and visualization at NREL propel technology innovation as a . Capabilities High-Performance Computing NREL is home to Peregrine-the largest high-performance computing system
76 FR 51002 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... with visual dysfunction related to traumatic brain injury, with an eye injury and a visual acuity in... of visual field in the injured eye. Categories of records in the system: Individual's full name... interventions or other operative procedures, follow up services and treatment, visual outcomes, and records with...
Physical Models that Provide Guidance in Visualization Deconstruction in an Inorganic Context
ERIC Educational Resources Information Center
Schiltz, Holly K.; Oliver-Hoyo, Maria T.
2012-01-01
Three physical model systems have been developed to help students deconstruct the visualization needed when learning symmetry and group theory. The systems provide students with physical and visual frames of reference to facilitate the complex visualization involved in symmetry concepts. The permanent reflection plane demonstration presents an…
Noise Source Visualization Using a Digital Voice Recorder and Low-Cost Sensors
Cho, Yong Thung
2018-01-01
Accurate sound visualization of noise sources is required for optimal noise control. Typically, noise measurement systems require microphones, an analog-digital converter, cables, a data acquisition system, etc., which may not be affordable for potential users. Also, many such systems are not highly portable and may not be convenient for travel. Handheld personal electronic devices such as smartphones and digital voice recorders with relatively lower costs and higher performance have become widely available recently. Even though such devices are highly portable, directly implementing them for noise measurement may lead to erroneous results since such equipment was originally designed for voice recording. In this study, external microphones were connected to a digital voice recorder to conduct measurements and the input received was processed for noise visualization. In this way, a low cost, compact sound visualization system was designed and introduced to visualize two actual noise sources for verification with different characteristics: an enclosed loud speaker and a small air compressor. Reasonable accuracy of noise visualization for these two sources was shown over a relatively wide frequency range. This very affordable and compact sound visualization system can be used for many actual noise visualization applications in addition to educational purposes. PMID:29614038
Balaram, Pooja; Hackett, Troy A.; Kaas, Jon H.
2013-01-01
Glutamate is the primary neurotransmitter utilized by the mammalian visual system for excitatory neurotransmission. The sequestration of glutamate into synaptic vesicles, and the subsequent transport of filled vesicles to the presynaptic terminal membrane, is regulated by a family of proteins known as vesicular glutamate transporters (VGLUTs). Two VGLUT proteins, VGLUT1 and VGLUT2, characterize distinct sets of glutamatergic projections between visual structures in rodents and prosimian primates, yet little is known about their distributions in the visual system of anthropoid primates. We have examined the mRNA and protein expression patterns of VGLUT1 and VGLUT2 in the visual system of macaque monkeys, an Old World anthropoid primate, in order to determine their relative distributions in the superior colliculus, lateral geniculate nucleus, pulvinar complex, V1 and V2. Distinct expression patterns for both VGLUT1 and VGLUT2 identified architectonic boundaries in all structures, as well as anatomical subdivisions of the superior colliculus, pulvinar complex, and V1. These results suggest that VGLUT1 and VGLUT2 clearly identify regions of glutamatergic input in visual structures, and may identify common architectonic features of visual areas and nuclei across the primate radiation. Additionally, we find that VGLUT1 and VGLUT2 characterize distinct subsets of glutamatergic projections in the macaque visual system; VGLUT2 predominates in driving or feedforward projections from lower order to higher order visual structures while VGLUT1 predominates in modulatory or feedback projections from higher order to lower order visual structures. The distribution of these two proteins suggests that VGLUT1 and VGLUT2 may identify class 1 and class 2 type glutamatergic projections within the primate visual system (Sherman and Guillery, 2006). PMID:23524295
Balaram, Pooja; Hackett, Troy A; Kaas, Jon H
2013-05-01
Glutamate is the primary neurotransmitter utilized by the mammalian visual system for excitatory neurotransmission. The sequestration of glutamate into synaptic vesicles, and the subsequent transport of filled vesicles to the presynaptic terminal membrane, is regulated by a family of proteins known as vesicular glutamate transporters (VGLUTs). Two VGLUT proteins, VGLUT1 and VGLUT2, characterize distinct sets of glutamatergic projections between visual structures in rodents and prosimian primates, yet little is known about their distributions in the visual system of anthropoid primates. We have examined the mRNA and protein expression patterns of VGLUT1 and VGLUT2 in the visual system of macaque monkeys, an Old World anthropoid primate, in order to determine their relative distributions in the superior colliculus, lateral geniculate nucleus, pulvinar complex, V1 and V2. Distinct expression patterns for both VGLUT1 and VGLUT2 identified architectonic boundaries in all structures, as well as anatomical subdivisions of the superior colliculus, pulvinar complex, and V1. These results suggest that VGLUT1 and VGLUT2 clearly identify regions of glutamatergic input in visual structures, and may identify common architectonic features of visual areas and nuclei across the primate radiation. Additionally, we find that VGLUT1 and VGLUT2 characterize distinct subsets of glutamatergic projections in the macaque visual system; VGLUT2 predominates in driving or feedforward projections from lower order to higher order visual structures while VGLUT1 predominates in modulatory or feedback projections from higher order to lower order visual structures. The distribution of these two proteins suggests that VGLUT1 and VGLUT2 may identify class 1 and class 2 type glutamatergic projections within the primate visual system (Sherman and Guillery, 2006). Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Perez-Martinez, P. J.; Miranda, R. M.; Andrade, M. D. F.
2017-12-01
In this manuscript we assess the capability of using mobility surveys and a high-scale assignment and emission model to study climate change and air quality impacts related to on-road transportation in the Megacity of São Paulo (MSP). Initially, we estimate CO2 emissions of light and heavy vehicles (LVs and HVs) at a spatial scale of 500m and temporal scale of an hour, using transport demand modeling. The estimates are based on origin and destination trip pairs and the height of the planetary boundary layer (PBL). These estimates, performed for the years 2007 and 2012, depend also on intermediate variables as dilution rates (D) and surface particulate-matter concentrations (PM). Secondly, we assess the changes in CO2 vehicle emissions from the MRSP over the period 2007-2012 (4% year-1). Consequently, CO2 emission inventories merge trip-based surveys, traffic assignments and road network database with air pollution monitoring data. Despite the difference of the methodologies, we use a road link bottom up vehicle activity based approach, the assessed emissions agree with the State's Emission Inventory. This paper shows that the CO2 emissions from LDVs and HDVs in the MSP in 2007 and 2012 were 8,477 and 10,075 tCeq day-1 (58% LVs and 42% HVs), respectively. CO2 emissions from vehicles show spatial patterns consistent with passenger and freight transport trips and road network assignments. Temporal profiles (diurnal, weekly and monthly) were estimated using traffic counts and congestion surrogates. The profiles were compared with average road-site (Western of MSP) and background (Jaraguá Peak) CO2 measurements available for 2014. On-road measurements showed one peak associated to the morning peak hour of vehicles (437±45 ppm) and another night peak (435±49 ppm) related to the low PBL (313 m) and D (329 m2 h-1). From on-road measurements, background values (414±2 ppm) were subtracted to estimate excess CO2 (12±8 ppm) directly attributed to vehicles. The inventory reflects the relationships between traffic patterns and emissions, and the developed methodology could be used to evaluate the impacts of forthcoming urban transport and emission control policies. In the future, our estimates will be verified with ground measurements of CO2 concentrations over a bigger monitoring network in the MSP.
Harnessing vision for computation.
Changizi, Mark
2008-01-01
Might it be possible to harness the visual system to carry out artificial computations, somewhat akin to how DNA has been harnessed to carry out computation? I provide the beginnings of a research programme attempting to do this. In particular, new techniques are described for building 'visual circuits' (or 'visual software') using wire, NOT, OR, and AND gates in a visual 6modality such that our visual system acts as 'visual hardware' computing the circuit, and generating a resultant perception which is the output.
NASA Astrophysics Data System (ADS)
Wan, Qianwen; Panetta, Karen; Agaian, Sos
2017-05-01
Autonomous facial recognition system is widely used in real-life applications, such as homeland border security, law enforcement identification and authentication, and video-based surveillance analysis. Issues like low image quality, non-uniform illumination as well as variations in poses and facial expressions can impair the performance of recognition systems. To address the non-uniform illumination challenge, we present a novel robust autonomous facial recognition system inspired by the human visual system based, so called, logarithmical image visualization technique. In this paper, the proposed method, for the first time, utilizes the logarithmical image visualization technique coupled with the local binary pattern to perform discriminative feature extraction for facial recognition system. The Yale database, the Yale-B database and the ATT database are used for computer simulation accuracy and efficiency testing. The extensive computer simulation demonstrates the method's efficiency, accuracy, and robustness of illumination invariance for facial recognition.
Dasgupta, Aritra; Lee, Joon-Yong; Wilson, Ryan; Lafrance, Robert A; Cramer, Nick; Cook, Kristin; Payne, Samuel
2017-01-01
Combining interactive visualization with automated analytical methods like statistics and data mining facilitates data-driven discovery. These visual analytic methods are beginning to be instantiated within mixed-initiative systems, where humans and machines collaboratively influence evidence-gathering and decision-making. But an open research question is that, when domain experts analyze their data, can they completely trust the outputs and operations on the machine-side? Visualization potentially leads to a transparent analysis process, but do domain experts always trust what they see? To address these questions, we present results from the design and evaluation of a mixed-initiative, visual analytics system for biologists, focusing on analyzing the relationships between familiarity of an analysis medium and domain experts' trust. We propose a trust-augmented design of the visual analytics system, that explicitly takes into account domain-specific tasks, conventions, and preferences. For evaluating the system, we present the results of a controlled user study with 34 biologists where we compare the variation of the level of trust across conventional and visual analytic mediums and explore the influence of familiarity and task complexity on trust. We find that despite being unfamiliar with a visual analytic medium, scientists seem to have an average level of trust that is comparable with the same in conventional analysis medium. In fact, for complex sense-making tasks, we find that the visual analytic system is able to inspire greater trust than other mediums. We summarize the implications of our findings with directions for future research on trustworthiness of visual analytic systems.
NASA Astrophysics Data System (ADS)
Gomes, Gary G.
1986-05-01
A cost effective and supportable color visual system has been developed to provide the necessary visual cues to United States Air Force B-52 bomber pilots training to become proficient at the task of inflight refueling. This camera model visual system approach is not suitable for all simulation applications, but provides a cost effective alternative to digital image generation systems when high fidelity of a single movable object is required. The system consists of a three axis gimballed KC-l35 tanker model, a range carriage mounted color augmented monochrome television camera, interface electronics, a color light valve projector and an infinity optics display system.
An annotation system for 3D fluid flow visualization
NASA Technical Reports Server (NTRS)
Loughlin, Maria M.; Hughes, John F.
1995-01-01
Annotation is a key activity of data analysis. However, current systems for data analysis focus almost exclusively on visualization. We propose a system which integrates annotations into a visualization system. Annotations are embedded in 3D data space, using the Post-it metaphor. This embedding allows contextual-based information storage and retrieval, and facilitates information sharing in collaborative environments. We provide a traditional database filter and a Magic Lens filter to create specialized views of the data. The system has been customized for fluid flow applications, with features which allow users to store parameters of visualization tools and sketch 3D volumes.
Moderate Perinatal Thyroid Hormone Insufficiency Alters Visual System Function in Adult Rats
Thyroid hormone (TH) is critical for many aspects of neurodevelopment, such as the visual system, but may be disrupted by many environmental contaminants. The experimental data demonstrating a role for TH on visual system development generally derives from studies in which deve...
Conceptual design study for an advanced cab and visual system, volume 2
NASA Technical Reports Server (NTRS)
Rue, R. J.; Cyrus, M. L.; Garnett, T. A.; Nachbor, J. W.; Seery, J. A.; Starr, R. L.
1980-01-01
The performance, design, construction and testing requirements are defined for developing an advanced cab and visual system. The rotorcraft system integration simulator is composed of the advanced cab and visual system and the rotorcraft system motion generator, and is part of an existing simulation facility. User's applications for the simulator include rotorcraft design development, product improvement, threat assessment, and accident investigation.
Visual analysis and exploration of complex corporate shareholder networks
NASA Astrophysics Data System (ADS)
Tekušová, Tatiana; Kohlhammer, Jörn
2008-01-01
The analysis of large corporate shareholder network structures is an important task in corporate governance, in financing, and in financial investment domains. In a modern economy, large structures of cross-corporation, cross-border shareholder relationships exist, forming complex networks. These networks are often difficult to analyze with traditional approaches. An efficient visualization of the networks helps to reveal the interdependent shareholding formations and the controlling patterns. In this paper, we propose an effective visualization tool that supports the financial analyst in understanding complex shareholding networks. We develop an interactive visual analysis system by combining state-of-the-art visualization technologies with economic analysis methods. Our system is capable to reveal patterns in large corporate shareholder networks, allows the visual identification of the ultimate shareholders, and supports the visual analysis of integrated cash flow and control rights. We apply our system on an extensive real-world database of shareholder relationships, showing its usefulness for effective visual analysis.
Robot Command Interface Using an Audio-Visual Speech Recognition System
NASA Astrophysics Data System (ADS)
Ceballos, Alexánder; Gómez, Juan; Prieto, Flavio; Redarce, Tanneguy
In recent years audio-visual speech recognition has emerged as an active field of research thanks to advances in pattern recognition, signal processing and machine vision. Its ultimate goal is to allow human-computer communication using voice, taking into account the visual information contained in the audio-visual speech signal. This document presents a command's automatic recognition system using audio-visual information. The system is expected to control the laparoscopic robot da Vinci. The audio signal is treated using the Mel Frequency Cepstral Coefficients parametrization method. Besides, features based on the points that define the mouth's outer contour according to the MPEG-4 standard are used in order to extract the visual speech information.
NASA Astrophysics Data System (ADS)
Samigulina, Galina A.; Shayakhmetova, Assem S.
2016-11-01
Research objective is the creation of intellectual innovative technology and information Smart-system of distance learning for visually impaired people. The organization of the available environment for receiving quality education for visually impaired people, their social adaptation in society are important and topical issues of modern education.The proposed Smart-system of distance learning for visually impaired people can significantly improve the efficiency and quality of education of this category of people. The scientific novelty of proposed Smart-system is using intelligent and statistical methods of processing multi-dimensional data, and taking into account psycho-physiological characteristics of perception and awareness learning information by visually impaired people.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steed, Chad A
Interactive data visualization leverages human visual perception and cognition to improve the accuracy and effectiveness of data analysis. When combined with automated data analytics, data visualization systems orchestrate the strengths of humans with the computational power of machines to solve problems neither approach can manage in isolation. In the intelligent transportation system domain, such systems are necessary to support decision making in large and complex data streams. In this chapter, we provide an introduction to several key topics related to the design of data visualization systems. In addition to an overview of key techniques and strategies, we will describe practicalmore » design principles. The chapter is concluded with a detailed case study involving the design of a multivariate visualization tool.« less
CLFs-based optimization control for a class of constrained visual servoing systems.
Song, Xiulan; Miaomiao, Fu
2017-03-01
In this paper, we use the control Lyapunov function (CLF) technique to present an optimized visual servo control method for constrained eye-in-hand robot visual servoing systems. With the knowledge of camera intrinsic parameters and depth of target changes, visual servo control laws (i.e. translation speed) with adjustable parameters are derived by image point features and some known CLF of the visual servoing system. The Fibonacci method is employed to online compute the optimal value of those adjustable parameters, which yields an optimized control law to satisfy constraints of the visual servoing system. The Lyapunov's theorem and the properties of CLF are used to establish stability of the constrained visual servoing system in the closed-loop with the optimized control law. One merit of the presented method is that there is no requirement of online calculating the pseudo-inverse of the image Jacobian's matrix and the homography matrix. Simulation and experimental results illustrated the effectiveness of the method proposed here. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Rendering visual events as sounds: Spatial attention capture by auditory augmented reality.
Stone, Scott A; Tata, Matthew S
2017-01-01
Many salient visual events tend to coincide with auditory events, such as seeing and hearing a car pass by. Information from the visual and auditory senses can be used to create a stable percept of the stimulus. Having access to related coincident visual and auditory information can help for spatial tasks such as localization. However not all visual information has analogous auditory percepts, such as viewing a computer monitor. Here, we describe a system capable of detecting and augmenting visual salient events into localizable auditory events. The system uses a neuromorphic camera (DAVIS 240B) to detect logarithmic changes of brightness intensity in the scene, which can be interpreted as salient visual events. Participants were blindfolded and asked to use the device to detect new objects in the scene, as well as determine direction of motion for a moving visual object. Results suggest the system is robust enough to allow for the simple detection of new salient stimuli, as well accurately encoding direction of visual motion. Future successes are probable as neuromorphic devices are likely to become faster and smaller in the future, making this system much more feasible.
Rendering visual events as sounds: Spatial attention capture by auditory augmented reality
Tata, Matthew S.
2017-01-01
Many salient visual events tend to coincide with auditory events, such as seeing and hearing a car pass by. Information from the visual and auditory senses can be used to create a stable percept of the stimulus. Having access to related coincident visual and auditory information can help for spatial tasks such as localization. However not all visual information has analogous auditory percepts, such as viewing a computer monitor. Here, we describe a system capable of detecting and augmenting visual salient events into localizable auditory events. The system uses a neuromorphic camera (DAVIS 240B) to detect logarithmic changes of brightness intensity in the scene, which can be interpreted as salient visual events. Participants were blindfolded and asked to use the device to detect new objects in the scene, as well as determine direction of motion for a moving visual object. Results suggest the system is robust enough to allow for the simple detection of new salient stimuli, as well accurately encoding direction of visual motion. Future successes are probable as neuromorphic devices are likely to become faster and smaller in the future, making this system much more feasible. PMID:28792518
75 FR 66131 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-27
... Integration and Visualization System,'' JUSTICE/FBI-021, which describes the Data Integration and... Liberties Officer. JUSTICE/FBI-021 SYSTEM NAME: Data Integration and Visualization System. * * * * * SYSTEM...
Understanding visualization: a formal approach using category theory and semiotics.
Vickers, Paul; Faith, Joe; Rossiter, Nick
2013-06-01
This paper combines the vocabulary of semiotics and category theory to provide a formal analysis of visualization. It shows how familiar processes of visualization fit the semiotic frameworks of both Saussure and Peirce, and extends these structures using the tools of category theory to provide a general framework for understanding visualization in practice, including: Relationships between systems, data collected from those systems, renderings of those data in the form of representations, the reading of those representations to create visualizations, and the use of those visualizations to create knowledge and understanding of the system under inspection. The resulting framework is validated by demonstrating how familiar information visualization concepts (such as literalness, sensitivity, redundancy, ambiguity, generalizability, and chart junk) arise naturally from it and can be defined formally and precisely. This paper generalizes previous work on the formal characterization of visualization by, inter alia, Ziemkiewicz and Kosara and allows us to formally distinguish properties of the visualization process that previous work does not.
Processing Of Visual Information In Primate Brains
NASA Technical Reports Server (NTRS)
Anderson, Charles H.; Van Essen, David C.
1991-01-01
Report reviews and analyzes information-processing strategies and pathways in primate retina and visual cortex. Of interest both in biological fields and in such related computational fields as artificial neural networks. Focuses on data from macaque, which has superb visual system similar to that of humans. Authors stress concept of "good engineering" in understanding visual system.
ERIC Educational Resources Information Center
Jan, James E.; Heaven, Roberta K. B.; Matsuba, Carey; Langley, M. Beth; Roman-Lantzy, Christine; Anthony, Tanni L
2013-01-01
Introduction: In recent years, major progress has been made in understanding the human visual system because of new investigative techniques. These developments often contradict older concepts about visual function. Methods: A detailed literature search and interprofessional discussions. Results: Recent innovative neurological tests are described…
DOT National Transportation Integrated Search
2012-03-01
This report introduces the design and implementation of a Web-based bridge information visual analytics system. This : project integrates Internet, multiple databases, remote sensing, and other visualization technologies. The result : combines a GIS ...
ERIC Educational Resources Information Center
Singleton, Chris; Henderson, Lisa-Marie
2006-01-01
This article reviews current knowledge about how the visual system recognizes letters and words, and the impact on reading when parts of the visual system malfunction. The physiology of eye and brain places important constraints on how we process text, and the efficient organization of the neurocognitive systems involved is not inherent but…
Two visual systems in monitoring of dynamic traffic: effects of visual disruption.
Zheng, Xianjun Sam; McConkie, George W
2010-05-01
Studies from neurophysiology and neuropsychology provide support for two separate object- and location-based visual systems, ventral and dorsal. In the driving context, a study was conducted using a change detection paradigm to explore drivers' ability to monitor the dynamic traffic flow, and the effects of visual disruption on these two visual systems. While driving, a discrete change, such as vehicle location, color, or identity, was occasionally made in one of the vehicles on the road ahead of the driver. Experiment results show that without visual disruption, all changes were detected very well; yet, these equally perceivable changes were disrupted differently by a brief blank display (150 ms): the detection of location changes was especially reduced. The disruption effects were also bigger for the parked vehicle compared to the moving ones. The findings support the different roles for two visual systems in monitoring the dynamic traffic: the "where", dorsal system, tracks vehicle spatiotemporal information on perceptual level, encoding information in a coarse and transient manner; whereas the "what", ventral system, monitors vehicles' featural information, encoding information more accurately and robustly. Both systems work together contributing to the driver's situation awareness of traffic. Benefits and limitations of using the driving simulation are also discussed. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Retinal and visual system: occupational and environmental toxicology.
Fox, Donald A
2015-01-01
Occupational chemical exposure often results in sensory systems alterations that occur without other clinical signs or symptoms. Approximately 3000 chemicals are toxic to the retina and central visual system. Their dysfunction can have immediate, long-term, and delayed effects on mental health, physical health, and performance and lead to increased occupational injuries. The aims of this chapter are fourfold. First, provide references on retinal/visual system structure, function, and assessment techniques. Second, discuss the retinal features that make it especially vulnerable to toxic chemicals. Third, review the clinical and corresponding experimental data regarding retinal/visual system deficits produced by occupational toxicants: organic solvents (carbon disulfide, trichloroethylene, tetrachloroethylene, styrene, toluene, and mixtures) and metals (inorganic lead, methyl mercury, and mercury vapor). Fourth, discuss occupational and environmental toxicants as risk factors for late-onset retinal diseases and degeneration. Overall, the toxicants altered color vision, rod- and/or cone-mediated electroretinograms, visual fields, spatial contrast sensitivity, and/or retinal thickness. The findings elucidate the importance of conducting multimodal noninvasive clinical, electrophysiologic, imaging and vision testing to monitor toxicant-exposed workers for possible retinal/visual system alterations. Finally, since the retina is a window into the brain, an increased awareness and understanding of retinal/visual system dysfunction should provide additional insight into acquired neurodegenerative disorders. © 2015 Elsevier B.V. All rights reserved.
Caudate nucleus reactivity predicts perceptual learning rate for visual feature conjunctions.
Reavis, Eric A; Frank, Sebastian M; Tse, Peter U
2015-04-15
Useful information in the visual environment is often contained in specific conjunctions of visual features (e.g., color and shape). The ability to quickly and accurately process such conjunctions can be learned. However, the neural mechanisms responsible for such learning remain largely unknown. It has been suggested that some forms of visual learning might involve the dopaminergic neuromodulatory system (Roelfsema et al., 2010; Seitz and Watanabe, 2005), but this hypothesis has not yet been directly tested. Here we test the hypothesis that learning visual feature conjunctions involves the dopaminergic system, using functional neuroimaging, genetic assays, and behavioral testing techniques. We use a correlative approach to evaluate potential associations between individual differences in visual feature conjunction learning rate and individual differences in dopaminergic function as indexed by neuroimaging and genetic markers. We find a significant correlation between activity in the caudate nucleus (a component of the dopaminergic system connected to visual areas of the brain) and visual feature conjunction learning rate. Specifically, individuals who showed a larger difference in activity between positive and negative feedback on an unrelated cognitive task, indicative of a more reactive dopaminergic system, learned visual feature conjunctions more quickly than those who showed a smaller activity difference. This finding supports the hypothesis that the dopaminergic system is involved in visual learning, and suggests that visual feature conjunction learning could be closely related to associative learning. However, no significant, reliable correlations were found between feature conjunction learning and genotype or dopaminergic activity in any other regions of interest. Copyright © 2015 Elsevier Inc. All rights reserved.
An infrared/video fusion system for military robotics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, A.W.; Roberts, R.S.
1997-08-05
Sensory information is critical to the telerobotic operation of mobile robots. In particular, visual sensors are a key component of the sensor package on a robot engaged in urban military operations. Visual sensors provide the robot operator with a wealth of information including robot navigation and threat assessment. However, simple countermeasures such as darkness, smoke, or blinding by a laser, can easily neutralize visual sensors. In order to provide a robust visual sensing system, an infrared sensor is required to augment the primary visual sensor. An infrared sensor can acquire useful imagery in conditions that incapacitate a visual sensor. Amore » simple approach to incorporating an infrared sensor into the visual sensing system is to display two images to the operator: side-by-side visual and infrared images. However, dual images might overwhelm the operator with information, and result in degraded robot performance. A better solution is to combine the visual and infrared images into a single image that maximizes scene information. Fusing visual and infrared images into a single image demands balancing the mixture of visual and infrared information. Humans are accustom to viewing and interpreting visual images. They are not accustom to viewing or interpreting infrared images. Hence, the infrared image must be used to enhance the visual image, not obfuscate it.« less
NASA Technical Reports Server (NTRS)
Uhlemann, H.; Geiser, G.
1975-01-01
Multivariable manual compensatory tracking experiments were carried out in order to determine typical strategies of the human operator and conditions for improvement of his performance if one of the visual displays of the tracking errors is supplemented by an auditory feedback. Because the tracking error of the system which is only visually displayed is found to decrease, but not in general that of the auditorally supported system, it was concluded that the auditory feedback unloads the visual system of the operator who can then concentrate on the remaining exclusively visual displays.
NASA Astrophysics Data System (ADS)
Duong, Tuan A.; Duong, Nghi; Le, Duong
2017-01-01
In this paper, we present an integration technique using a bio-inspired, control-based visual and olfactory receptor system to search for elusive targets in practical environments where the targets cannot be seen obviously by either sensory data. Bio-inspired Visual System is based on a modeling of extended visual pathway which consists of saccadic eye movements and visual pathway (vertebrate retina, lateral geniculate nucleus and visual cortex) to enable powerful target detections of noisy, partial, incomplete visual data. Olfactory receptor algorithm, namely spatial invariant independent component analysis, that was developed based on data of old factory receptor-electronic nose (enose) of Caltech, is adopted to enable the odorant target detection in an unknown environment. The integration of two systems is a vital approach and sets up a cornerstone for effective and low-cost of miniaturized UAVs or fly robots for future DOD and NASA missions, as well as for security systems in Internet of Things environments.
NASA GES DISC Level 2 Aerosol Analysis and Visualization Services
NASA Technical Reports Server (NTRS)
Wei, Jennifer; Petrenko, Maksym; Ichoku, Charles; Yang, Wenli; Johnson, James; Zhao, Peisheng; Kempler, Steve
2015-01-01
Overview of NASA GES DISC Level 2 aerosol analysis and visualization services: DQViz (Data Quality Visualization)MAPSS (Multi-sensor Aerosol Products Sampling System), and MAPSS_Explorer (Multi-sensor Aerosol Products Sampling System Explorer).
Research issues of geometry-based visual languages and some solutions
NASA Astrophysics Data System (ADS)
Green, Thorn G.
This dissertation addresses the problem of how to design visual language systems that are based upon Geometric Algebra, and provide a visual coupling of algebraic expressions and geometric depictions. This coupling of algebraic expressions and geometric depictions provides a new means for expressing both mathematical and geometric relationships present in mathematics, physics, and Computer-Aided Geometric Design (CAGD). Another significant feature of such a system is that the result of changing a parameter (by dragging the mouse) can be seen immediately in the depiction(s) of all expressions that use that parameter. This greatly aides the cognition of the relationships between variables. Systems for representing such a coupling of algebra and geometry have characteristics of both visual language systems, and systems for scientific visualization. Instead of using a parsing or dataflow paradigm for the visual language representation, the systems instead represent equations as manipulatible constrained diagrams for their visualization. This requires that the design of such a system have (but is not limited to) a means for parsing equations entered by the user, a scheme for producing a visual representation of these equations; techniques for maintaining the coupling between the expressions entered and the diagrams displayed; algorithms for maintaining the consistency of the diagrams; and, indexing capabilities that are efficient enough to allow diagrams to be created, and manipulated in a short enough period of time. The author proposes solutions for how such a design can be realized.
Soares, Sandra C.; Maior, Rafael S.; Isbell, Lynne A.; Tomaz, Carlos; Nishijo, Hisao
2017-01-01
Primates are distinguished from other mammals by their heavy reliance on the visual sense, which occurred as a result of natural selection continually favoring those individuals whose visual systems were more responsive to challenges in the natural world. Here we describe two independent but also interrelated visual systems, one cortical and the other subcortical, both of which have been modified and expanded in primates for different functions. Available evidence suggests that while the cortical visual system mainly functions to give primates the ability to assess and adjust to fluid social and ecological environments, the subcortical visual system appears to function as a rapid detector and first responder when time is of the essence, i.e., when survival requires very quick action. We focus here on the subcortical visual system with a review of behavioral and neurophysiological evidence that demonstrates its sensitivity to particular, often emotionally charged, ecological and social stimuli, i.e., snakes and fearful and aggressive facial expressions in conspecifics. We also review the literature on subcortical involvement during another, less emotional, situation that requires rapid detection and response—visually guided reaching and grasping during locomotion—to further emphasize our argument that the subcortical visual system evolved as a rapid detector/first responder, a function that remains in place today. Finally, we argue that investigating deficits in this subcortical system may provide greater understanding of Parkinson's disease and Autism Spectrum disorders (ASD). PMID:28261046
Parallel Visualization Co-Processing of Overnight CFD Propulsion Applications
NASA Technical Reports Server (NTRS)
Edwards, David E.; Haimes, Robert
1999-01-01
An interactive visualization system pV3 is being developed for the investigation of advanced computational methodologies employing visualization and parallel processing for the extraction of information contained in large-scale transient engineering simulations. Visual techniques for extracting information from the data in terms of cutting planes, iso-surfaces, particle tracing and vector fields are included in this system. This paper discusses improvements to the pV3 system developed under NASA's Affordable High Performance Computing project.
Vision and visual navigation in nocturnal insects.
Warrant, Eric; Dacke, Marie
2011-01-01
With their highly sensitive visual systems, nocturnal insects have evolved a remarkable capacity to discriminate colors, orient themselves using faint celestial cues, fly unimpeded through a complicated habitat, and navigate to and from a nest using learned visual landmarks. Even though the compound eyes of nocturnal insects are significantly more sensitive to light than those of their closely related diurnal relatives, their photoreceptors absorb photons at very low rates in dim light, even during demanding nocturnal visual tasks. To explain this apparent paradox, it is hypothesized that the necessary bridge between retinal signaling and visual behavior is a neural strategy of spatial and temporal summation at a higher level in the visual system. Exactly where in the visual system this summation takes place, and the nature of the neural circuitry that is involved, is currently unknown but provides a promising avenue for future research.
Hsu, Chi-Lin; Chou, Chih-Hsuan; Huang, Shih-Chuan; Lin, Chia-Yi; Lin, Meng-Ying; Tung, Chun-Che; Lin, Chun-Yen; Lai, Ivan Pochou; Zou, Yan-Fang; Youngson, Neil A; Lin, Shau-Ping; Yang, Chang-Hao; Chen, Shih-Kuo; Gau, Susan Shur-Fen; Huang, Hsien-Sung
2018-03-15
Visual system development is light-experience dependent, which strongly implicates epigenetic mechanisms in light-regulated maturation. Among many epigenetic processes, genomic imprinting is an epigenetic mechanism through which monoallelic gene expression occurs in a parent-of-origin-specific manner. It is unknown if genomic imprinting contributes to visual system development. We profiled the transcriptome and imprintome during critical periods of mouse visual system development under normal- and dark-rearing conditions using B6/CAST F1 hybrid mice. We identified experience-regulated, isoform-specific and brain-region-specific imprinted genes. We also found imprinted microRNAs were predominantly clustered into the Dlk1-Dio3 imprinted locus with light experience affecting some imprinted miRNA expression. Our findings provide the first comprehensive analysis of light-experience regulation of the transcriptome and imprintome during critical periods of visual system development. Our results may contribute to therapeutic strategies for visual impairments and circadian rhythm disorders resulting from a dysfunctional imprintome.
NASA Technical Reports Server (NTRS)
Haines, R. F.
1973-01-01
Thirty six students and 54 commercial airline pilots were tested in the fog chamber to determine the effect of runway edge and centerline light intensity and spacing, fog density, ambient luminance level, and lateral and vertical offset distance of the subject from the runway's centerline upon horizontal visual range. These data were obtained to evaluate the adequacy of a balanced lighting system to provide maximum visual range in fog viewing both centerline and runway edge lights. The daytime system was compared against two other candidate lighting systems; the nighttime system was compared against other candidate lighting systems. The second objective was to determine if visual range is affected by lights between the subject and the farthestmost light visible through the fog. The third objective was to determine if college student subjects differ from commercial airline pilots in their horizontal visual range through fog. Two studies were conducted.
NASA Astrophysics Data System (ADS)
Massof, Robert W.; Schmidt, Karen M.; Laby, Daniel M.; Kirschen, David; Meadows, David
2013-09-01
Visual acuity, a forced-choice psychophysical measure of visual spatial resolution, is the sine qua non of clinical visual impairment testing in ophthalmology and optometry patients with visual system disorders ranging from refractive error to retinal, optic nerve, or central visual system pathology. Visual acuity measures are standardized against a norm, but it is well known that visual acuity depends on a variety of stimulus parameters, including contrast and exposure duration. This paper asks if it is possible to estimate a single global visual state measure from visual acuity measures as a function of stimulus parameters that can represent the patient's overall visual health state with a single variable. Psychophysical theory (at the sensory level) and psychometric theory (at the decision level) are merged to identify the conditions that must be satisfied to derive a global visual state measure from parameterised visual acuity measures. A global visual state measurement model is developed and tested with forced-choice visual acuity measures from 116 subjects with no visual impairments and 560 subjects with uncorrected refractive error. The results are in agreement with the expectations of the model.
Pilot Task Profiles, Human Factors, And Image Realism
NASA Astrophysics Data System (ADS)
McCormick, Dennis
1982-06-01
Computer Image Generation (CIG) visual systems provide real time scenes for state-of-the-art flight training simulators. The visual system reauires a greater understanding of training tasks, human factors, and the concept of image realism to produce an effective and efficient training scene than is required by other types of visual systems. Image realism must be defined in terms of pilot visual information reauirements. Human factors analysis of training and perception is necessary to determine the pilot's information requirements. System analysis then determines how the CIG and display device can best provide essential information to the pilot. This analysis procedure ensures optimum training effectiveness and system performance.
ERIC Educational Resources Information Center
Hsiao, Janet H.; Lam, Sze Man
2013-01-01
Through computational modeling, here we examine whether visual and task characteristics of writing systems alone can account for lateralization differences in visual word recognition between different languages without assuming influence from left hemisphere (LH) lateralized language processes. We apply a hemispheric processing model of face…
Phosphene phenomenon: a new concept.
Bókkon, István
2008-05-01
This paper proposes a new biopsychophysical concept of phosphene phenomenon. Namely, visual sensation of phosphenes is due to the intrinsic perception of ultraweak bioluminescent photon emission of cells in the visual system. In other words, phosphenes are bioluminescent biophotons in the visual system induced by various stimuli (mechanical, electrical, magnetic, ionizing radiation, etc.) as well as random bioluminescent biophotons firings of cells in the visual pathway. This biophoton emission can become conscious if induced or spontaneous biophoton emission of cells in the visual system exceeds a distinct threshold. Neuronal biophoton communication can occur by means of non-visual neuronal opsins and natural photosensitive biomolecules. Our interpretation is in direct connection with the functional roles of free radicals and excited biomolecules in living cells.
DOT National Transportation Integrated Search
2009-12-01
The goals of integration should be: Supporting domain oriented data analysis through the use of : knowledge augmented visual analytics system. In this project, we focus on: : Providing interactive data exploration for bridge managements. : ...
Visual system manifestations of Alzheimer's disease.
Kusne, Yael; Wolf, Andrew B; Townley, Kate; Conway, Mandi; Peyman, Gholam A
2017-12-01
Alzheimer's disease (AD) is an increasingly common disease with massive personal and economic costs. While it has long been known that AD impacts the visual system, there has recently been an increased focus on understanding both pathophysiological mechanisms that may be shared between the eye and brain and how related biomarkers could be useful for AD diagnosis. Here, were review pertinent cellular and molecular mechanisms of AD pathophysiology, the presence of AD pathology in the visual system, associated functional changes, and potential development of diagnostic tools based on the visual system. Additionally, we discuss links between AD and visual disorders, including possible pathophysiological mechanisms and their relevance for improving our understanding of AD. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
He, Hui; Fan, Guotao; Ye, Jianwei; Zhang, Weizhe
2013-01-01
It is of great significance to research the early warning system for large-scale network security incidents. It can improve the network system's emergency response capabilities, alleviate the cyber attacks' damage, and strengthen the system's counterattack ability. A comprehensive early warning system is presented in this paper, which combines active measurement and anomaly detection. The key visualization algorithm and technology of the system are mainly discussed. The large-scale network system's plane visualization is realized based on the divide and conquer thought. First, the topology of the large-scale network is divided into some small-scale networks by the MLkP/CR algorithm. Second, the sub graph plane visualization algorithm is applied to each small-scale network. Finally, the small-scale networks' topologies are combined into a topology based on the automatic distribution algorithm of force analysis. As the algorithm transforms the large-scale network topology plane visualization problem into a series of small-scale network topology plane visualization and distribution problems, it has higher parallelism and is able to handle the display of ultra-large-scale network topology.
2016-01-01
Although much is known about the regenerative capacity of retinal ganglion cells, very significant barriers remain in our ability to restore visual function following traumatic injury or disease-induced degeneration. Here we summarize our current understanding of the factors regulating axon guidance and target engagement in regenerating axons, and review the state of the field of neural regeneration, focusing on the visual system and highlighting studies using other model systems that can inform analysis of visual system regeneration. This overview is motivated by a Society for Neuroscience Satellite meeting, “Reconnecting Neurons in the Visual System,” held in October 2015 sponsored by the National Eye Institute as part of their “Audacious Goals Initiative” and co-organized by Carol Mason (Columbia University) and Michael Crair (Yale University). The collective wisdom of the conference participants pointed to important gaps in our knowledge and barriers to progress in promoting the restoration of visual system function. This article is thus a summary of our existing understanding of visual system regeneration and provides a blueprint for future progress in the field. PMID:27798125
Designing a visualization system for hydrological data
NASA Astrophysics Data System (ADS)
Fuhrmann, Sven
2000-02-01
The field of hydrology is, as any other scientific field, strongly affected by a massive technological evolution. The spread of modern information and communication technology within the last three decades has led to an increased collection, availability and use of spatial and temporal digital hydrological data. In a two-year research period a working group in Muenster applied and developed methods for the visualization of digital hydrological data and the documentation of hydrological models. A low-cost multimedial, hydrological visualization system (HydroVIS) for the Weser river catchment was developed. The research group designed HydroVIS under freeware constraints and tried to show what kind of multimedia visualization techniques can be effectively used with a nonprofit hydrological visualization system. The system's visual components include features such as electronic maps, temporal and nontemporal cartographic animations, the display of geologic profiles, interactive diagrams and hypertext, including photographs and tables.
Cognitive processing in the primary visual cortex: from perception to memory.
Supèr, Hans
2002-01-01
The primary visual cortex is the first cortical area of the visual system that receives information from the external visual world. Based on the receptive field characteristics of the neurons in this area, it has been assumed that the primary visual cortex is a pure sensory area extracting basic elements of the visual scene. This information is then subsequently further processed upstream in the higher-order visual areas and provides us with perception and storage of the visual environment. However, recent findings show that such neural implementations are observed in the primary visual cortex. These neural correlates are expressed by the modulated activity of the late response of a neuron to a stimulus, and most likely depend on recurrent interactions between several areas of the visual system. This favors the concept of a distributed nature of visual processing in perceptual organization.
Visualizing speciation in artificial cichlid fish.
Clement, Ross
2006-01-01
The Cichlid Speciation Project (CSP) is an ALife simulation system for investigating open problems in the speciation of African cichlid fish. The CSP can be used to perform a wide range of experiments that show that speciation is a natural consequence of certain biological systems. A visualization system capable of extracting the history of speciation from low-level trace data and creating a phylogenetic tree has been implemented. Unlike previous approaches, this visualization system presents a concrete trace of speciation, rather than a summary of low-level information from which the viewer can make subjective decisions on how speciation progressed. The phylogenetic trees are a more objective visualization of speciation, and enable automated collection and summarization of the results of experiments. The visualization system is used to create a phylogenetic tree from an experiment that models sympatric speciation.
Alvarez, George A.; Nakayama, Ken; Konkle, Talia
2016-01-01
Visual search is a ubiquitous visual behavior, and efficient search is essential for survival. Different cognitive models have explained the speed and accuracy of search based either on the dynamics of attention or on similarity of item representations. Here, we examined the extent to which performance on a visual search task can be predicted from the stable representational architecture of the visual system, independent of attentional dynamics. Participants performed a visual search task with 28 conditions reflecting different pairs of categories (e.g., searching for a face among cars, body among hammers, etc.). The time it took participants to find the target item varied as a function of category combination. In a separate group of participants, we measured the neural responses to these object categories when items were presented in isolation. Using representational similarity analysis, we then examined whether the similarity of neural responses across different subdivisions of the visual system had the requisite structure needed to predict visual search performance. Overall, we found strong brain/behavior correlations across most of the higher-level visual system, including both the ventral and dorsal pathways when considering both macroscale sectors as well as smaller mesoscale regions. These results suggest that visual search for real-world object categories is well predicted by the stable, task-independent architecture of the visual system. NEW & NOTEWORTHY Here, we ask which neural regions have neural response patterns that correlate with behavioral performance in a visual processing task. We found that the representational structure across all of high-level visual cortex has the requisite structure to predict behavior. Furthermore, when directly comparing different neural regions, we found that they all had highly similar category-level representational structures. These results point to a ubiquitous and uniform representational structure in high-level visual cortex underlying visual object processing. PMID:27832600
Porter, Megan L.; Kingston, Alexandra C. N.; McCready, Robert; Cameron, Evan G.; Hofmann, Christopher M.; Suarez, Lauren; Olsen, Glenn H.; Cronin, Thomas W.; Robinson, Phyllis R.
2014-01-01
Vision has been investigated in many species of birds, but few studies have considered the visual systems of large birds and the particular implications of large eyes and long-life spans on visual system capabilities. To address these issues we investigated the visual system of the whooping crane Grus americana (Gruiformes, Gruidae), which is one of only two North American crane species. It is a large, long-lived bird in which UV sensitivity might be reduced by chromatic aberration and entrance of UV radiation into the eye could be detrimental to retinal tissues. To investigate the whooping crane visual system we used microspectrophotometry to determine the absorbance spectra of retinal oil droplets and to investigate whether the ocular media (i.e. the lens and cornea) absorb UV radiation. In vitro expression and reconstitution was used to determine the absorbance spectra of rod and cone visual pigments. The rod visual pigments had wavelengths of peak absorbance (λmax) at 500 nm, whereas the cone visual pigment λmax values were determined to be 404 nm (SWS1), 450 nm (SWS2), 499 nm (RH2) and 561 nm (LWS), similar to other characterized bird visual pigment absorbance values. The oil droplet cut-off wavelength (λcut) values similarly fell within ranges recorded in other avian species: 576 nm (R-type), 522 nm (Y-type), 506 nm (P-type) and 448 nm (C-type). We confirm that G. americana has a violet-sensitive visual system; however, as a consequence of the λmax of the SWS1 visual pigment (404 nm), it might also have some UV sensitivity. PMID:25267845
Developing Guidelines for Assessing Visual Analytics Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholtz, Jean
2011-07-01
In this paper, we develop guidelines for evaluating visual analytic environments based on a synthesis of reviews for the entries to the 2009 Visual Analytics Science and Technology (VAST) Symposium Challenge and from a user study with professional intelligence analysts. By analyzing the 2009 VAST Challenge reviews we gained a better understanding of what is important to our reviewers, both visualization researchers and professional analysts. We also report on a small user study with professional analysts to determine the important factors that they use in evaluating visual analysis systems. We then looked at guidelines developed by researchers in various domainsmore » and synthesized these into an initial set for use by others in the community. In a second part of the user study, we looked at guidelines for a new aspect of visual analytic systems – the generation of reports. Future visual analytic systems have been challenged to help analysts generate their reports. In our study we worked with analysts to understand the criteria they used to evaluate the quality of analytic reports. We propose that this knowledge will be useful as researchers look at systems to automate some of the report generation.1 Based on these efforts, we produced some initial guidelines for evaluating visual analytic environment and for evaluation of analytic reports. It is important to understand that these guidelines are initial drafts and are limited in scope because of the type of tasks for which the visual analytic systems used in the studies in this paper were designed. More research and refinement is needed by the Visual Analytics Community to provide additional evaluation guidelines for different types of visual analytic environments.« less
Porter, Megan L.; Kingston, Alexandra C. N.; McCready, Robert; Cameron, Evan G.; Hofmann, Christopher M.; Suarez, Lauren; Olsen, Glenn H.; Cronin, Thomas W.; Robinson, Phyllis R.
2014-01-01
Vision has been investigated in many species of birds, but few studies have considered the visual systems of large birds and the particular implications of large eyes and long-life spans on visual system capabilities. To address these issues we investigated the visual system of the whooping crane, Grus americana (Gruiformes: Gruidae). G. americana (an endangered species) is one of only two North American crane species and represents a large, long-lived bird where ultraviolet sensitivity may be degraded by chromatic aberrations and entrance of ultraviolet light into the eye could be detrimental to retinal tissues. To investigate the whooping crane visual system we used microspectrophotometry to determine the absorbance spectra of retinal oil droplets and to investigate if the ocular media (i.e., the lens and cornea) absorbs UV light. In vitro expression and reconstitution was used to determine the absorbance spectra of rod and cone visual pigments. The rod visual pigments had wavelengths of peak absorbance (λmax) at 500 nm, while the cone visual pigments λmax values were determined to be 404 nm (SWS1), 450 nm (SWS2), 499 nm (RH2), and 561 nm (LWS), similar to other characterized bird visual pigment absorbance values. The oil droplet cutoff wavelength (λcut) values similarly fell within ranges recorded from other avian species: 576 nm (R-type), 522 nm (Y-type), 506 nm (P-type), and 448 nm (C-type). We confirm that G. americana has a violet-sensitive visual system, although based on the λmax of the SWS1 visual pigment (404 nm) may also have some ability for UV sensitivity.
High Performance Molecular Visualization: In-Situ and Parallel Rendering with EGL.
Stone, John E; Messmer, Peter; Sisneros, Robert; Schulten, Klaus
2016-05-01
Large scale molecular dynamics simulations produce terabytes of data that is impractical to transfer to remote facilities. It is therefore necessary to perform visualization tasks in-situ as the data are generated, or by running interactive remote visualization sessions and batch analyses co-located with direct access to high performance storage systems. A significant challenge for deploying visualization software within clouds, clusters, and supercomputers involves the operating system software required to initialize and manage graphics acceleration hardware. Recently, it has become possible for applications to use the Embedded-system Graphics Library (EGL) to eliminate the requirement for windowing system software on compute nodes, thereby eliminating a significant obstacle to broader use of high performance visualization applications. We outline the potential benefits of this approach in the context of visualization applications used in the cloud, on commodity clusters, and supercomputers. We discuss the implementation of EGL support in VMD, a widely used molecular visualization application, and we outline benefits of the approach for molecular visualization tasks on petascale computers, clouds, and remote visualization servers. We then provide a brief evaluation of the use of EGL in VMD, with tests using developmental graphics drivers on conventional workstations and on Amazon EC2 G2 GPU-accelerated cloud instance types. We expect that the techniques described here will be of broad benefit to many other visualization applications.
High Performance Molecular Visualization: In-Situ and Parallel Rendering with EGL
Stone, John E.; Messmer, Peter; Sisneros, Robert; Schulten, Klaus
2016-01-01
Large scale molecular dynamics simulations produce terabytes of data that is impractical to transfer to remote facilities. It is therefore necessary to perform visualization tasks in-situ as the data are generated, or by running interactive remote visualization sessions and batch analyses co-located with direct access to high performance storage systems. A significant challenge for deploying visualization software within clouds, clusters, and supercomputers involves the operating system software required to initialize and manage graphics acceleration hardware. Recently, it has become possible for applications to use the Embedded-system Graphics Library (EGL) to eliminate the requirement for windowing system software on compute nodes, thereby eliminating a significant obstacle to broader use of high performance visualization applications. We outline the potential benefits of this approach in the context of visualization applications used in the cloud, on commodity clusters, and supercomputers. We discuss the implementation of EGL support in VMD, a widely used molecular visualization application, and we outline benefits of the approach for molecular visualization tasks on petascale computers, clouds, and remote visualization servers. We then provide a brief evaluation of the use of EGL in VMD, with tests using developmental graphics drivers on conventional workstations and on Amazon EC2 G2 GPU-accelerated cloud instance types. We expect that the techniques described here will be of broad benefit to many other visualization applications. PMID:27747137
Information processing in the primate visual system - An integrated systems perspective
NASA Technical Reports Server (NTRS)
Van Essen, David C.; Anderson, Charles H.; Felleman, Daniel J.
1992-01-01
The primate visual system contains dozens of distinct areas in the cerebral cortex and several major subcortical structures. These subdivisions are extensively interconnected in a distributed hierarchical network that contains several intertwined processing streams. A number of strategies are used for efficient information processing within this hierarchy. These include linear and nonlinear filtering, passage through information bottlenecks, and coordinated use of multiple types of information. In addition, dynamic regulation of information flow within and between visual areas may provide the computational flexibility needed for the visual system to perform a broad spectrum of tasks accurately and at high resolution.
Handa, T; Ishikawa, H; Shimizu, K; Kawamura, R; Nakayama, H; Sawada, K
2009-11-01
Virtual reality has recently been highlighted as a promising medium for visual presentation and entertainment. A novel apparatus for testing binocular visual function using a hemispherical visual display system, 'CyberDome', has been developed and tested. Subjects comprised 40 volunteers (mean age, 21.63 years) with corrected visual acuity of -0.08 (LogMAR) or better, and stereoacuity better than 100 s of arc on the Titmus stereo test. Subjects were able to experience visual perception like being surrounded by visual images, a feature of the 'CyberDome' hemispherical visual display system. Visual images to the right and left eyes were projected and superimposed on the dome screen, allowing test images to be seen independently by each eye using polarizing glasses. The hemispherical visual display was 1.4 m in diameter. Three test parameters were evaluated: simultaneous perception (subjective angle of strabismus), motor fusion amplitude (convergence and divergence), and stereopsis (binocular disparity at 1260, 840, and 420 s of arc). Testing was performed in volunteer subjects with normal binocular vision, and results were compared with those using a major amblyoscope. Subjective angle of strabismus and motor fusion amplitude showed a significant correlation between our test and the major amblyoscope. All subjects could perceive the stereoscopic target with a binocular disparity of 480 s of arc. Our novel apparatus using the CyberDome, a hemispherical visual display system, was able to quantitatively evaluate binocular function. This apparatus offers clinical promise in the evaluation of binocular function.
Relating Standardized Visual Perception Measures to Simulator Visual System Performance
NASA Technical Reports Server (NTRS)
Kaiser, Mary K.; Sweet, Barbara T.
2013-01-01
Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).
Organization of the Drosophila larval visual circuit
Gendre, Nanae; Neagu-Maier, G Larisa; Fetter, Richard D; Schneider-Mizell, Casey M; Truman, James W; Zlatic, Marta; Cardona, Albert
2017-01-01
Visual systems transduce, process and transmit light-dependent environmental cues. Computation of visual features depends on photoreceptor neuron types (PR) present, organization of the eye and wiring of the underlying neural circuit. Here, we describe the circuit architecture of the visual system of Drosophila larvae by mapping the synaptic wiring diagram and neurotransmitters. By contacting different targets, the two larval PR-subtypes create two converging pathways potentially underlying the computation of ambient light intensity and temporal light changes already within this first visual processing center. Locally processed visual information then signals via dedicated projection interneurons to higher brain areas including the lateral horn and mushroom body. The stratified structure of the larval optic neuropil (LON) suggests common organizational principles with the adult fly and vertebrate visual systems. The complete synaptic wiring diagram of the LON paves the way to understanding how circuits with reduced numerical complexity control wide ranges of behaviors.
Kukona, Anuenue; Tabor, Whitney
2011-01-01
The visual world paradigm presents listeners with a challenging problem: they must integrate two disparate signals, the spoken language and the visual context, in support of action (e.g., complex movements of the eyes across a scene). We present Impulse Processing, a dynamical systems approach to incremental eye movements in the visual world that suggests a framework for integrating language, vision, and action generally. Our approach assumes that impulses driven by the language and the visual context impinge minutely on a dynamical landscape of attractors corresponding to the potential eye-movement behaviors of the system. We test three unique predictions of our approach in an empirical study in the visual world paradigm, and describe an implementation in an artificial neural network. We discuss the Impulse Processing framework in relation to other models of the visual world paradigm. PMID:21609355
The two-visual-systems hypothesis and the perspectival features of visual experience.
Foley, Robert T; Whitwell, Robert L; Goodale, Melvyn A
2015-09-01
Some critics of the two-visual-systems hypothesis (TVSH) argue that it is incompatible with the fundamentally egocentric nature of visual experience (what we call the 'perspectival account'). The TVSH proposes that the ventral stream, which delivers up our visual experience of the world, works in an allocentric frame of reference, whereas the dorsal stream, which mediates the visual control of action, uses egocentric frames of reference. Given that the TVSH is also committed to the claim that dorsal-stream processing does not contribute to the contents of visual experience, it has been argued that the TVSH cannot account for the egocentric features of our visual experience. This argument, however, rests on a misunderstanding about how the operations mediating action and the operations mediating perception are specified in the TVSH. In this article, we emphasize the importance of the 'outputs' of the two-systems to the specification of their respective operations. We argue that once this point is appreciated, it becomes evident that the TVSH is entirely compatible with a perspectival account of visual experience. Copyright © 2015 Elsevier Inc. All rights reserved.
Aguilar, Mario; Peot, Mark A; Zhou, Jiangying; Simons, Stephen; Liao, Yuwei; Metwalli, Nader; Anderson, Mark B
2012-03-01
The mammalian visual system is still the gold standard for recognition accuracy, flexibility, efficiency, and speed. Ongoing advances in our understanding of function and mechanisms in the visual system can now be leveraged to pursue the design of computer vision architectures that will revolutionize the state of the art in computer vision.
Three-dimensional user interfaces for scientific visualization
NASA Technical Reports Server (NTRS)
Vandam, Andries
1995-01-01
The main goal of this project is to develop novel and productive user interface techniques for creating and managing visualizations of computational fluid dynamics (CFD) datasets. We have implemented an application framework in which we can visualize computational fluid dynamics user interfaces. This UI technology allows users to interactively place visualization probes in a dataset and modify some of their parameters. We have also implemented a time-critical scheduling system which strives to maintain a constant frame-rate regardless of the number of visualization techniques. In the past year, we have published parts of this research at two conferences, the research annotation system at Visualization 1994, and the 3D user interface at UIST 1994. The real-time scheduling system has been submitted to SIGGRAPH 1995 conference. Copies of these documents are included with this report.
Towards a visual modeling approach to designing microelectromechanical system transducers
NASA Astrophysics Data System (ADS)
Dewey, Allen; Srinivasan, Vijay; Icoz, Evrim
1999-12-01
In this paper, we address initial design capture and system conceptualization of microelectromechanical system transducers based on visual modeling and design. Visual modeling frames the task of generating hardware description language (analog and digital) component models in a manner similar to the task of generating software programming language applications. A structured topological design strategy is employed, whereby microelectromechanical foundry cell libraries are utilized to facilitate the design process of exploring candidate cells (topologies), varying key aspects of the transduction for each topology, and determining which topology best satisfies design requirements. Coupled-energy microelectromechanical system characterizations at a circuit level of abstraction are presented that are based on branch constitutive relations and an overall system of simultaneous differential and algebraic equations. The resulting design methodology is called visual integrated-microelectromechanical VHDL-AMS interactive design (VHDL-AMS is visual hardware design language for analog and mixed signal).
METHODS FOR MONITORING THE EFFECTS OF ENVIRONMENTAL TOXINS ON THE VISUAL SYSTEM.
A high percentage of neurotoxic compounds adversely effect the visual system. Our goal is to apply the tools of vision science to problems of toxicological import, exposure-related alterations in visual physiology, psychophysical function, and ocular development. Methods can ...
Visualizing Terrestrial and Aquatic Systems in 3-D
The environmental modeling community has a long-standing need for affordable, easy-to-use tools that support 3-D visualization of complex spatial and temporal model output. The Visualization of Terrestrial and Aquatic Systems project (VISTAS) aims to help scientists produce effe...
Modeling human comprehension of data visualizations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzen, Laura E.; Haass, Michael Joseph; Divis, Kristin Marie
This project was inspired by two needs. The first is a need for tools to help scientists and engineers to design effective data visualizations for communicating information, whether to the user of a system, an analyst who must make decisions based on complex data, or in the context of a technical report or publication. Most scientists and engineers are not trained in visualization design, and they could benefit from simple metrics to assess how well their visualization's design conveys the intended message. In other words, will the most important information draw the viewer's attention? The second is the need formore » cognition-based metrics for evaluating new types of visualizations created by researchers in the information visualization and visual analytics communities. Evaluating visualizations is difficult even for experts. However, all visualization methods and techniques are intended to exploit the properties of the human visual system to convey information efficiently to a viewer. Thus, developing evaluation methods that are rooted in the scientific knowledge of the human visual system could be a useful approach. In this project, we conducted fundamental research on how humans make sense of abstract data visualizations, and how this process is influenced by their goals and prior experience. We then used that research to develop a new model, the Data Visualization Saliency Model, that can make accurate predictions about which features in an abstract visualization will draw a viewer's attention. The model is an evaluation tool that can address both of the needs described above, supporting both visualization research and Sandia mission needs.« less
RAVE: Rapid Visualization Environment
NASA Technical Reports Server (NTRS)
Klumpar, D. M.; Anderson, Kevin; Simoudis, Avangelos
1994-01-01
Visualization is used in the process of analyzing large, multidimensional data sets. However, the selection and creation of visualizations that are appropriate for the characteristics of a particular data set and the satisfaction of the analyst's goals is difficult. The process consists of three tasks that are performed iteratively: generate, test, and refine. The performance of these tasks requires the utilization of several types of domain knowledge that data analysts do not often have. Existing visualization systems and frameworks do not adequately support the performance of these tasks. In this paper we present the RApid Visualization Environment (RAVE), a knowledge-based system that interfaces with commercial visualization frameworks and assists a data analyst in quickly and easily generating, testing, and refining visualizations. RAVE was used for the visualization of in situ measurement data captured by spacecraft.
End-to-End Flow Control for Visual-Haptic Communication under Bandwidth Change
NASA Astrophysics Data System (ADS)
Yashiro, Daisuke; Tian, Dapeng; Yakoh, Takahiro
This paper proposes an end-to-end flow controller for visual-haptic communication. A visual-haptic communication system transmits non-real-time packets, which contain large-size visual data, and real-time packets, which contain small-size haptic data. When the transmission rate of visual data exceeds the communication bandwidth, the visual-haptic communication system becomes unstable owing to buffer overflow. To solve this problem, an end-to-end flow controller is proposed. This controller determines the optimal transmission rate of visual data on the basis of the traffic conditions, which are estimated by the packets for haptic communication. Experimental results confirm that in the proposed method, a short packet-sending interval and a short delay are achieved under bandwidth change, and thus, high-precision visual-haptic communication is realized.
Visualization of reservoir simulation data with an immersive virtual reality system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, B.K.
1996-10-01
This paper discusses an investigation into the use of an immersive virtual reality (VR) system to visualize reservoir simulation output data. The hardware and software configurations of the test-immersive VR system are described and compared to a nonimmersive VR system and to an existing workstation screen-based visualization system. The structure of 3D reservoir simulation data and the actions to be performed on the data within the VR system are discussed. The subjective results of the investigation are then presented, followed by a discussion of possible future work.
Verbal Modification via Visual Display
ERIC Educational Resources Information Center
Richmond, Edmun B.; Wallace-Childers, La Donna
1977-01-01
The inability of foreign language students to produce acceptable approximations of new vowel sounds initiated a study to devise a real-time visual display system whereby the students could match vowel production to a visual pedagogical model. The system used amateur radio equipment and a standard oscilloscope. (CHK)
RELEVANCE OF VISUAL EFFECTS OF VOLATILE ORGANIC COMPOUNDS TO HUMAN HEALTH RISK ASSESSMENT
Traditional measures of neurotoxicity have included assessment of sensory, cognitive, and motor function. Visual system function and the neurobiological substrates are well characterized across species. Dysfunction in the visual system may be specific or may be surrogate for mor...
High-resolution remotely sensed small target detection by imitating fly visual perception mechanism.
Huang, Fengchen; Xu, Lizhong; Li, Min; Tang, Min
2012-01-01
The difficulty and limitation of small target detection methods for high-resolution remote sensing data have been a recent research hot spot. Inspired by the information capture and processing theory of fly visual system, this paper endeavors to construct a characterized model of information perception and make use of the advantages of fast and accurate small target detection under complex varied nature environment. The proposed model forms a theoretical basis of small target detection for high-resolution remote sensing data. After the comparison of prevailing simulation mechanism behind fly visual systems, we propose a fly-imitated visual system method of information processing for high-resolution remote sensing data. A small target detector and corresponding detection algorithm are designed by simulating the mechanism of information acquisition, compression, and fusion of fly visual system and the function of pool cell and the character of nonlinear self-adaption. Experiments verify the feasibility and rationality of the proposed small target detection model and fly-imitated visual perception method.
Protein-Protein Interaction Network and Gene Ontology
NASA Astrophysics Data System (ADS)
Choi, Yunkyu; Kim, Seok; Yi, Gwan-Su; Park, Jinah
Evolution of computer technologies makes it possible to access a large amount and various kinds of biological data via internet such as DNA sequences, proteomics data and information discovered about them. It is expected that the combination of various data could help researchers find further knowledge about them. Roles of a visualization system are to invoke human abilities to integrate information and to recognize certain patterns in the data. Thus, when the various kinds of data are examined and analyzed manually, an effective visualization system is an essential part. One instance of these integrated visualizations can be combination of protein-protein interaction (PPI) data and Gene Ontology (GO) which could help enhance the analysis of PPI network. We introduce a simple but comprehensive visualization system that integrates GO and PPI data where GO and PPI graphs are visualized side-by-side and supports quick reference functions between them. Furthermore, the proposed system provides several interactive visualization methods for efficiently analyzing the PPI network and GO directedacyclic- graph such as context-based browsing and common ancestors finding.
Comprehensive visual field test & diagnosis system in support of astronaut health and performance
NASA Astrophysics Data System (ADS)
Fink, Wolfgang; Clark, Jonathan B.; Reisman, Garrett E.; Tarbell, Mark A.
Long duration spaceflight, permanent human presence on the Moon, and future human missions to Mars will require autonomous medical care to address both expected and unexpected risks. An integrated non-invasive visual field test & diagnosis system is presented for the identification, characterization, and automated classification of visual field defects caused by the spaceflight environment. This system will support the onboard medical provider and astronauts on space missions with an innovative, non-invasive, accurate, sensitive, and fast visual field test. It includes a database for examination data, and a software package for automated visual field analysis and diagnosis. The system will be used to detect and diagnose conditions affecting the visual field, while in space and on Earth, permitting the timely application of therapeutic countermeasures before astronaut health or performance are impaired. State-of-the-art perimetry devices are bulky, thereby precluding application in a spaceflight setting. In contrast, the visual field test & diagnosis system requires only a touchscreen-equipped computer or touchpad device, which may already be in use for other purposes (i.e., no additional payload), and custom software. The system has application in routine astronaut assessment (Clinical Status Exam), pre-, in-, and post-flight monitoring, and astronaut selection. It is deployable in operational space environments, such as aboard the International Space Station or during future missions to or permanent presence on the Moon and Mars.
FROMS3D: New Software for 3-D Visualization of Fracture Network System in Fractured Rock Masses
NASA Astrophysics Data System (ADS)
Noh, Y. H.; Um, J. G.; Choi, Y.
2014-12-01
A new software (FROMS3D) is presented to visualize fracture network system in 3-D. The software consists of several modules that play roles in management of borehole and field fracture data, fracture network modelling, visualization of fracture geometry in 3-D and calculation and visualization of intersections and equivalent pipes between fractures. Intel Parallel Studio XE 2013, Visual Studio.NET 2010 and the open source VTK library were utilized as development tools to efficiently implement the modules and the graphical user interface of the software. The results have suggested that the developed software is effective in visualizing 3-D fracture network system, and can provide useful information to tackle the engineering geological problems related to strength, deformability and hydraulic behaviors of the fractured rock masses.
A low-cost and versatile system for projecting wide-field visual stimuli within fMRI scanners
Greco, V.; Frijia, F.; Mikellidou, K.; Montanaro, D.; Farini, A.; D’Uva, M.; Poggi, P.; Pucci, M.; Sordini, A.; Morrone, M. C.; Burr, D. C.
2016-01-01
We have constructed and tested a custom-made magnetic-imaging-compatible visual projection system designed to project on a very wide visual field (~80°). A standard projector was modified with a coupling lens, projecting images into the termination of an image fiber. The other termination of the fiber was placed in the 3-T scanner room with a projection lens, which projected the images relayed by the fiber onto a screen over the head coil, viewed by a participant wearing magnifying goggles. To validate the system, wide-field stimuli were presented in order to identify retinotopic visual areas. The results showed that this low-cost and versatile optical system may be a valuable tool to map visual areas in the brain that process peripheral receptive fields. PMID:26092392
Fischer-Baum, Simon; Englebretson, Robert
2016-08-01
Reading relies on the recognition of units larger than single letters and smaller than whole words. Previous research has linked sublexical structures in reading to properties of the visual system, specifically on the parallel processing of letters that the visual system enables. But whether the visual system is essential for this to happen, or whether the recognition of sublexical structures may emerge by other means, is an open question. To address this question, we investigate braille, a writing system that relies exclusively on the tactile rather than the visual modality. We provide experimental evidence demonstrating that adult readers of (English) braille are sensitive to sublexical units. Contrary to prior assumptions in the braille research literature, we find strong evidence that braille readers do indeed access sublexical structure, namely the processing of multi-cell contractions as single orthographic units and the recognition of morphemes within morphologically-complex words. Therefore, we conclude that the recognition of sublexical structure is not exclusively tied to the visual system. However, our findings also suggest that there are aspects of morphological processing on which braille and print readers differ, and that these differences may, crucially, be related to reading using the tactile rather than the visual sensory modality. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Tallman, Oliver H.
A digital simulation of a model for the processing of visual images is derived from known aspects of the human visual system. The fundamental principle of computation suggested by a biological model is a transformation that distributes information contained in an input stimulus everywhere in a transform domain. Each sensory input contributes under…
Arakawa, Takahiro; Ando, Eri; Wang, Xin; Kumiko, Miyajima; Kudo, Hiroyuki; Saito, Hirokazu; Mitani, Tomoyo; Takahashi, Mitsuo; Mitsubayashi, Kohji
2012-01-01
A two-dimensional gaseous ethanol visualization system has been developed and demonstrated using a horseradish peroxidase-luminol-hydrogen peroxide system with high-purity luminol solution and a chemiluminescence (CL) enhancer. This system measures ethanol concentrations as intensities of CL via the luminol reaction. CL was emitted when the gaseous ethanol was injected onto an enzyme-immobilized membrane, which was employed as a screen for two-dimensional gas visualization. The average intensity of CL on the substrate was linearly related to the concentration of standard ethanol gas. These results were compared with the CL intensity of the CCD camera recording image in the visualization system. This system is available for gas components not only for spatial but also for temporal analysis in real time. A high-purity sodium salt HG solution (L-HG) instead of standard luminol solution and an enhancer, eosin Y (EY) solution, were adapted for improvement of CL intensity of the system. The visualization of gaseous ethanol was achieved at a detection limit of 3 ppm at optimized concentrations of L-HG solution and EY. Copyright © 2011 John Wiley & Sons, Ltd.
Visual information mining in remote sensing image archives
NASA Astrophysics Data System (ADS)
Pelizzari, Andrea; Descargues, Vincent; Datcu, Mihai P.
2002-01-01
The present article focuses on the development of interactive exploratory tools for visually mining the image content in large remote sensing archives. Two aspects are treated: the iconic visualization of the global information in the archive and the progressive visualization of the image details. The proposed methods are integrated in the Image Information Mining (I2M) system. The images and image structure in the I2M system are indexed based on a probabilistic approach. The resulting links are managed by a relational data base. Both the intrinsic complexity of the observed images and the diversity of user requests result in a great number of associations in the data base. Thus new tools have been designed to visualize, in iconic representation the relationships created during a query or information mining operation: the visualization of the query results positioned on the geographical map, quick-looks gallery, visualization of the measure of goodness of the query, visualization of the image space for statistical evaluation purposes. Additionally the I2M system is enhanced with progressive detail visualization in order to allow better access for operator inspection. I2M is a three-tier Java architecture and is optimized for the Internet.
A massively asynchronous, parallel brain.
Zeki, Semir
2015-05-19
Whether the visual brain uses a parallel or a serial, hierarchical, strategy to process visual signals, the end result appears to be that different attributes of the visual scene are perceived asynchronously--with colour leading form (orientation) by 40 ms and direction of motion by about 80 ms. Whatever the neural root of this asynchrony, it creates a problem that has not been properly addressed, namely how visual attributes that are perceived asynchronously over brief time windows after stimulus onset are bound together in the longer term to give us a unified experience of the visual world, in which all attributes are apparently seen in perfect registration. In this review, I suggest that there is no central neural clock in the (visual) brain that synchronizes the activity of different processing systems. More likely, activity in each of the parallel processing-perceptual systems of the visual brain is reset independently, making of the brain a massively asynchronous organ, just like the new generation of more efficient computers promise to be. Given the asynchronous operations of the brain, it is likely that the results of activities in the different processing-perceptual systems are not bound by physiological interactions between cells in the specialized visual areas, but post-perceptually, outside the visual brain.
European dental students' opinions about visual and digital tooth colour determination systems.
Dozic, Alma; Kharbanda, Aron K; Kamell, Hassib; Brand, Henk S
2011-12-01
The aim of the study was to investigate students' opinion about visual and digital tooth colour determination education at different European dental schools. A cross-sectional web-based survey was created, containing nine dichotomous, multiple choice and 5-point Likert scale questions. The questionnaire was distributed amongst students of 40 European dental schools. Seven hundred and ninety-nine completed questionnaires from students of 15 dental schools were analysed statistically. Vitapan Classical and Vitapan 3D-Master are the most frequently used visual determination systems at European dental schools. Most students responded with "neutral" regarding whether they find it easy to identify the colour of teeth with a visual determination system (range 2.8-3.6). A minority of the dental students had received education in digital imaging systems (2-47%). The Easyshade was the most frequently mentioned digital system. The majority of the students who did not receive education on digital systems would like to see this topic added to the curriculum (77-100%). The dental students who had worked with both methods found it significantly easier to determine tooth colour with a digital system than with a visual system (mean score 3.5 ± 0.8 vs. 3.0 ± 0.8). Tooth colour determination programmes show a considerable variation across European dental schools. Based upon the outcomes of this study, students prefer digital imaging systems over visual systems, and like to have (more) education about digital tooth colour imaging. Copyright © 2011 Elsevier Ltd. All rights reserved.
Arcaro, Michael J; Honey, Christopher J; Mruczek, Ryan E B; Kastner, Sabine; Hasson, Uri
2015-02-19
The human visual system can be divided into over two-dozen distinct areas, each of which contains a topographic map of the visual field. A fundamental question in vision neuroscience is how the visual system integrates information from the environment across different areas. Using neuroimaging, we investigated the spatial pattern of correlated BOLD signal across eight visual areas on data collected during rest conditions and during naturalistic movie viewing. The correlation pattern between areas reflected the underlying receptive field organization with higher correlations between cortical sites containing overlapping representations of visual space. In addition, the correlation pattern reflected the underlying widespread eccentricity organization of visual cortex, in which the highest correlations were observed for cortical sites with iso-eccentricity representations including regions with non-overlapping representations of visual space. This eccentricity-based correlation pattern appears to be part of an intrinsic functional architecture that supports the integration of information across functionally specialized visual areas.
The Two Modes of Visual Processing: Implications for Spatial Orientation
NASA Technical Reports Server (NTRS)
Leibowitz, H. W.; Shupert, C. L.; Post, R. B.
1984-01-01
The roles of the focal and ambient visual systems in spatial orientation are discussed. The two modes are defined and compared. The contribution of each system is illustrated through examples such as spatial disorientation/motion sickness, vehicle guidance/night driving, visual narrowing under stress/cortical brain damage, and aircraft instrumentation. Emphasis is placed on the need for testing procedures for the ambient system.
Characteristics of flight simulator visual systems
NASA Technical Reports Server (NTRS)
Statler, I. C. (Editor)
1981-01-01
The physical parameters of the flight simulator visual system that characterize the system and determine its fidelity are identified and defined. The characteristics of visual simulation systems are discussed in terms of the basic categories of spatial, energy, and temporal properties corresponding to the three fundamental quantities of length, mass, and time. Each of these parameters are further addressed in relation to its effect, its appropriate units or descriptors, methods of measurement, and its use or importance to image quality.
Measuring the performance of visual to auditory information conversion.
Tan, Shern Shiou; Maul, Tomás Henrique Bode; Mennie, Neil Russell
2013-01-01
Visual to auditory conversion systems have been in existence for several decades. Besides being among the front runners in providing visual capabilities to blind users, the auditory cues generated from image sonification systems are still easier to learn and adapt to compared to other similar techniques. Other advantages include low cost, easy customizability, and universality. However, every system developed so far has its own set of strengths and weaknesses. In order to improve these systems further, we propose an automated and quantitative method to measure the performance of such systems. With these quantitative measurements, it is possible to gauge the relative strengths and weaknesses of different systems and rank the systems accordingly. Performance is measured by both the interpretability and also the information preservation of visual to auditory conversions. Interpretability is measured by computing the correlation of inter image distance (IID) and inter sound distance (ISD) whereas the information preservation is computed by applying Information Theory to measure the entropy of both visual and corresponding auditory signals. These measurements provide a basis and some insights on how the systems work. With an automated interpretability measure as a standard, more image sonification systems can be developed, compared, and then improved. Even though the measure does not test systems as thoroughly as carefully designed psychological experiments, a quantitative measurement like the one proposed here can compare systems to a certain degree without incurring much cost. Underlying this research is the hope that a major breakthrough in image sonification systems will allow blind users to cost effectively regain enough visual functions to allow them to lead secure and productive lives.
Farage, Miranda A; Singh, Mukul; Ledger, William J
2009-07-01
An enhanced visualization technique using polarized light (Syris v600 enhanced visualization system; Syris Scientific LLC, Gray, ME) detects surface and subsurface ( approximately 1 mm depth) inflammation. We sought to compare the Syris v600 system with unaided visual inspection and colposcopy of the female genitalia. Erythema and dryness of the vulva, introitus, vagina, and cervix were visualized and scored by each method in patients with and without vulvitis. Subsurface visualization was more sensitive in detecting genital erythema and dryness at all sites whether or not symptoms were present. Subsurface inflammation of the introitus, vagina, and cervix only was detected uniquely in women with vulvar vestibulitis syndrome (VVS). A subset of women presenting with VVS exhibited subclinical inflammation of the vulva vestibule and vagina (designated VVS/lichen sclerosus subgroup). Enhanced visualization of the genital epithelial subsurface with cross-polarized light may assist in diagnosing subclinical inflammation in vulvar conditions heretofore characterized as sensory syndromes.
Real-time scalable visual analysis on mobile devices
NASA Astrophysics Data System (ADS)
Pattath, Avin; Ebert, David S.; May, Richard A.; Collins, Timothy F.; Pike, William
2008-02-01
Interactive visual presentation of information can help an analyst gain faster and better insight from data. When combined with situational or context information, visualization on mobile devices is invaluable to in-field responders and investigators. However, several challenges are posed by the form-factor of mobile devices in developing such systems. In this paper, we classify these challenges into two broad categories - issues in general mobile computing and issues specific to visual analysis on mobile devices. Using NetworkVis and Infostar as example systems, we illustrate some of the techniques that we employed to overcome many of the identified challenges. NetworkVis is an OpenVG-based real-time network monitoring and visualization system developed for Windows Mobile devices. Infostar is a flash-based interactive, real-time visualization application intended to provide attendees access to conference information. Linked time-synchronous visualization, stylus/button-based interactivity, vector graphics, overview-context techniques, details-on-demand and statistical information display are some of the highlights of these applications.
Video content parsing based on combined audio and visual information
NASA Astrophysics Data System (ADS)
Zhang, Tong; Kuo, C.-C. Jay
1999-08-01
While previous research on audiovisual data segmentation and indexing primarily focuses on the pictorial part, significant clues contained in the accompanying audio flow are often ignored. A fully functional system for video content parsing can be achieved more successfully through a proper combination of audio and visual information. By investigating the data structure of different video types, we present tools for both audio and visual content analysis and a scheme for video segmentation and annotation in this research. In the proposed system, video data are segmented into audio scenes and visual shots by detecting abrupt changes in audio and visual features, respectively. Then, the audio scene is categorized and indexed as one of the basic audio types while a visual shot is presented by keyframes and associate image features. An index table is then generated automatically for each video clip based on the integration of outputs from audio and visual analysis. It is shown that the proposed system provides satisfying video indexing results.
Highly conserved D-loop-like nuclear mitochondrial sequences (Numts) in tiger (Panthera tigris).
Zhang, Wenping; Zhang, Zhihe; Shen, Fujun; Hou, Rong; Lv, Xiaoping; Yue, Bisong
2006-08-01
Using oligonucleotide primers designed to match hypervariable segments I (HVS-1) of Panthera tigris mitochondrial DNA (mtDNA), we amplified two different PCR products (500 bp and 287 bp) in the tiger (Panthera tigris), but got only one PCR product (287 bp) in the leopard (Panthera pardus). Sequence analyses indicated that the sequence of 287 bp was a D-loop-like nuclear mitochondrial sequence (Numts), indicating a nuclear transfer that occurred approximately 4.8-17 million years ago in the tiger and 4.6-16 million years ago in the leopard. Although the mtDNA D-loop sequence has a rapid rate of evolution, the 287-bp Numts are highly conserved; they are nearly identical in tiger subspecies and only 1.742% different between tiger and leopard. Thus, such sequences represent molecular 'fossils' that can shed light on evolution of the mitochondrial genome and may be the most appropriate outgroup for phylogenetic analysis. This is also proved by comparing the phylogenetic trees reconstructed using the D-loop sequence of snow leopard and the 287-bp Numts as outgroup.
Kucharewicz, Weronika; Distelfeld, Assaf; Bilger, Wolfgang; Müller, Maren; Munné-Bosch, Sergi; Hensel, Götz
2017-01-01
Abstract WHIRLY1 in barley was isolated as a potential regulator of the senescence-associated gene HvS40. In order to investigate whether the plastid–nucleus-located DNA/RNA-binding protein WHIRLY1 plays a role in regulation of leaf senescence, primary foliage leaves from transgenic barley plants with an RNAi-mediated knockdown of the WHIRLY1 gene were characterized by typical senescence parameters, namely pigment contents, function and composition of the photosynthetic apparatus, as well as expression of selected genes known to be either down- or up-regulated during leaf senescence. When the plants were grown at low light intensity, senescence progression was similar between wild-type and RNAi-W1 plants. Likewise, dark-induced senescence of detached leaves was not affected by reduction of WHIRLY1. When plants were grown at high light intensity, however, senescence was induced prematurely in wild-type plants but was delayed in RNAi-W1 plants. This result suggests that WHIRLY1 plays a role in light sensing and/or stress communication between chloroplasts and the nucleus. PMID:28338757
Stereoscopic augmented reality for laparoscopic surgery.
Kang, Xin; Azizian, Mahdi; Wilson, Emmanuel; Wu, Kyle; Martin, Aaron D; Kane, Timothy D; Peters, Craig A; Cleary, Kevin; Shekhar, Raj
2014-07-01
Conventional laparoscopes provide a flat representation of the three-dimensional (3D) operating field and are incapable of visualizing internal structures located beneath visible organ surfaces. Computed tomography (CT) and magnetic resonance (MR) images are difficult to fuse in real time with laparoscopic views due to the deformable nature of soft-tissue organs. Utilizing emerging camera technology, we have developed a real-time stereoscopic augmented-reality (AR) system for laparoscopic surgery by merging live laparoscopic ultrasound (LUS) with stereoscopic video. The system creates two new visual cues: (1) perception of true depth with improved understanding of 3D spatial relationships among anatomical structures, and (2) visualization of critical internal structures along with a more comprehensive visualization of the operating field. The stereoscopic AR system has been designed for near-term clinical translation with seamless integration into the existing surgical workflow. It is composed of a stereoscopic vision system, a LUS system, and an optical tracker. Specialized software processes streams of imaging data from the tracked devices and registers those in real time. The resulting two ultrasound-augmented video streams (one for the left and one for the right eye) give a live stereoscopic AR view of the operating field. The team conducted a series of stereoscopic AR interrogations of the liver, gallbladder, biliary tree, and kidneys in two swine. The preclinical studies demonstrated the feasibility of the stereoscopic AR system during in vivo procedures. Major internal structures could be easily identified. The system exhibited unobservable latency with acceptable image-to-video registration accuracy. We presented the first in vivo use of a complete system with stereoscopic AR visualization capability. This new capability introduces new visual cues and enhances visualization of the surgical anatomy. The system shows promise to improve the precision and expand the capacity of minimally invasive laparoscopic surgeries.
The Visual System of Zebrafish and its Use to Model Human Ocular Diseases
Gestri, Gaia; Link, Brian A; Neuhauss, Stephan CF
2011-01-01
Free swimming zebrafish larvae depend mainly on their sense of vision to evade predation and to catch prey. Hence there is strong selective pressure on the fast maturation of visual function and indeed the visual system already supports a number of visually-driven behaviors in the newly hatched larvae. The ability to exploit the genetic and embryonic accessibility of the zebrafish in combination with a behavioral assessment of visual system function has made the zebrafish a popular model to study vision and its diseases. Here, we review the anatomy, physiology and development of the zebrafish eye as the basis to relate the contributions of the zebrafish to our understanding of human ocular diseases. PMID:21595048
6D Visualization of Multidimensional Data by Means of Cognitive Technology
NASA Astrophysics Data System (ADS)
Vitkovskiy, V.; Gorohov, V.; Komarinskiy, S.
2010-12-01
On the basis of the cognitive graphics concept, we worked out the SW-system for visualization and analysis. It allows to train and to aggravate intuition of researcher, to raise his interest and motivation to the creative, scientific cognition, to realize process of dialogue with the very problems simultaneously. The Space Hedgehog system is the next step in the cognitive means of the multidimensional data analyze. The technique and technology cognitive 6D visualization of the multidimensional data is developed on the basis of the cognitive visualization research and technology development. The Space Hedgehog system allows direct dynamic visualization of 6D objects. It is developed with use of experience of the program Space Walker creation and its applications.
Level-2 Milestone 4797: Early Users on Max, Sequoia Visualization Cluster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cupps, Kim C.
This report documents the fact that an early user has run successfully on Max, the Sequoia visualization cluster, ASC L2 milestone 4797: Early Users on Sequoia Visualization System (Max), due December 31, 2013. The Max visualization and data analysis cluster will provide Sequoia users with compute cycles and an interactive option for data exploration and analysis. The system will be integrated in the first quarter of FY14 and the system is expected to be moved to the classified network by the second quarter of FY14. The goal of this milestone is to have early users running their visualization and datamore » analysis work on the Max cluster on the classified network.« less
Visual Complexity in Orthographic Learning: Modeling Learning across Writing System Variations
ERIC Educational Resources Information Center
Chang, Li-Yun; Plaut, David C.; Perfetti, Charles A.
2016-01-01
The visual complexity of orthographies varies across writing systems. Prior research has shown that complexity strongly influences the initial stage of reading development: the perceptual learning of grapheme forms. This study presents a computational simulation that examines the degree to which visual complexity leads to grapheme learning…
Visual Teaching Strategies for Children with Autism.
ERIC Educational Resources Information Center
Tissot, Catherine; Evans, Roy
2003-01-01
Describes the types of children with autism that would benefit from visual teaching strategies. Discusses the benefits and disadvantages of some of the more well-known programs that use visual teaching strategies, including movement-based systems relying on sign language, and materials-based systems such as Treatment and Education of Autistic and…
NASA Technical Reports Server (NTRS)
Wang, P.; Li, P.
1998-01-01
A high-resolution numerical study on parallel systems is reported on three-dimensional, time-dependent, thermal convective flows. A parallel implentation on the finite volume method with a multigrid scheme is discussed, and a parallel visualization systemm is developed on distributed systems for visualizing the flow.
Exploratory Climate Data Visualization and Analysis Using DV3D and UVCDAT
NASA Technical Reports Server (NTRS)
Maxwell, Thomas
2012-01-01
Earth system scientists are being inundated by an explosion of data generated by ever-increasing resolution in both global models and remote sensors. Advanced tools for accessing, analyzing, and visualizing very large and complex climate data are required to maintain rapid progress in Earth system research. To meet this need, NASA, in collaboration with the Ultra-scale Visualization Climate Data Analysis Tools (UVCOAT) consortium, is developing exploratory climate data analysis and visualization tools which provide data analysis capabilities for the Earth System Grid (ESG). This paper describes DV3D, a UV-COAT package that enables exploratory analysis of climate simulation and observation datasets. OV3D provides user-friendly interfaces for visualization and analysis of climate data at a level appropriate for scientists. It features workflow inte rfaces, interactive 40 data exploration, hyperwall and stereo visualization, automated provenance generation, and parallel task execution. DV30's integration with CDAT's climate data management system (COMS) and other climate data analysis tools provides a wide range of high performance climate data analysis operations. DV3D expands the scientists' toolbox by incorporating a suite of rich new exploratory visualization and analysis methods for addressing the complexity of climate datasets.
Collaborative volume visualization with applications to underwater acoustic signal processing
NASA Astrophysics Data System (ADS)
Jarvis, Susan; Shane, Richard T.
2000-08-01
Distributed collaborative visualization systems represent a technology whose time has come. Researchers at the Fraunhofer Center for Research in Computer Graphics have been working in the areas of collaborative environments and high-end visualization systems for several years. The medical application. TeleInVivo, is an example of a system which marries visualization and collaboration. With TeleInvivo, users can exchange and collaboratively interact with volumetric data sets in geographically distributed locations. Since examination of many physical phenomena produce data that are naturally volumetric, the visualization frameworks used by TeleInVivo have been extended for non-medical applications. The system can now be made compatible with almost any dataset that can be expressed in terms of magnitudes within a 3D grid. Coupled with advances in telecommunications, telecollaborative visualization is now possible virtually anywhere. Expert data quality assurance and analysis can occur remotely and interactively without having to send all the experts into the field. Building upon this point-to-point concept of collaborative visualization, one can envision a larger pooling of resources to form a large overview of a region of interest from contributions of numerous distributed members.
Using Visualization in Cockpit Decision Support Systems
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2005-01-01
In order to safely operate their aircraft, pilots must make rapid decisions based on integrating and processing large amounts of heterogeneous information. Visual displays are often the most efficient method of presenting safety-critical data to pilots in real time. However, care must be taken to ensure the pilot is provided with the appropriate amount of information to make effective decisions and not become cognitively overloaded. The results of two usability studies of a prototype airflow hazard visualization cockpit decision support system are summarized. The studies demonstrate that such a system significantly improves the performance of helicopter pilots landing under turbulent conditions. Based on these results, design principles and implications for cockpit decision support systems using visualization are presented.
A GUI visualization system for airborne lidar image data to reconstruct 3D city model
NASA Astrophysics Data System (ADS)
Kawata, Yoshiyuki; Koizumi, Kohei
2015-10-01
A visualization toolbox system with graphical user interfaces (GUIs) was developed for the analysis of LiDAR point cloud data, as a compound object oriented widget application in IDL (Interractive Data Language). The main features in our system include file input and output abilities, data conversion capability from ascii formatted LiDAR point cloud data to LiDAR image data whose pixel value corresponds the altitude measured by LiDAR, visualization of 2D/3D images in various processing steps and automatic reconstruction ability of 3D city model. The performance and advantages of our graphical user interface (GUI) visualization system for LiDAR data are demonstrated.
Fukuoka, Hideki; Nagaya, Masahiro; Toba, Kenji
2015-10-29
The current state of eye diseases and treatments in the elderly as well as the relationships between dementia and systemic diseases remain unclear. Therefore, this study evaluated the prevalence of eye diseases, visual impairment, cognitive impairment, and falls (which are an important health issue and are considered one of the Geriatric Giants) in super-elderly people in Japan. The subjects were 31 elderly people (62 eyes; mean age: 84.6 ± 8.8 years; age range 61-98 years) who were admitted to a geriatric health services facility. Eye treatment status, systemic diseases, dementia, and recent falls were investigated. Eye examinations including vision and intraocular pressure measurement, and slit-lamp biomicroscopy were conducted. Mean best corrected visual acuity (logMAR) was 0.51 ± 0.56, and mean intraocular pressure was 13.7 ± 3.5 mmHg. Approximately half of the subjects exhibited excavation of the optic nerve head including cataracts and glaucoma. Ten subjects had visual impairment (i.e., visual acuity of the eye with the better vision <20/40). The mean Hasegawa dementia scale scores between the visually impaired and non-visually impaired groups were 10.2 ± 6 and 16 ± 8 points, respectively (p < 0.05). Furthermore, 70% of subjects with visual impairment experienced a fall in the past year compared to 48% of those without visual impairment, although the difference was not significant. Regarding systemic diseases, there were 6, 5, and 15 cases of diabetes, hyperlipidemia, and hypertension, respectively. There was no significant difference between these systemic diseases and visual function after adjusted for age and gender. The percentages of patients with age-related eye diseases and poor visual acuity in a geriatric health services facility were extremely high. Compared to those without visual impairment, those with visual impairment had lower dementia scores and a higher rate of falls.
Yeh, Fung-Huei; Yang, Chung-Chieh
2014-12-01
This study proposed a new information and commutation technology assisted blind telephone interview (ICT-ABTI) system to help visually impaired people to do telephone interview jobs as normal sighted people and create more diverse employment opportunities for them. The study also used an ABAB design to assess the system with seven visually impaired people. As the results, they can accomplish 3070 effective telephone interviews per month independently. The results also show that working performance of the visually impaired can be improved effectively with appropriate design of operation working flow and accessible software. The visually impaired become productive, lucrative, and self-sufficient by using ICT-ABTI system to do telephone interview jobs. The results were also shared through the APEC Digital Opportunity Center platform to help visually impaired in Philippines, Malaysia and China. Copyright © 2014 Elsevier Ltd. All rights reserved.
Conceptual design study for an advanced cab and visual system, volume 1
NASA Technical Reports Server (NTRS)
Rue, R. J.; Cyrus, M. L.; Garnett, T. A.; Nachbor, J. W.; Seery, J. A.; Starr, R. L.
1980-01-01
A conceptual design study was conducted to define requirements for an advanced cab and visual system. The rotorcraft system integration simulator is for engineering studies in the area of mission associated vehicle handling qualities. Principally a technology survey and assessment of existing and proposed simulator visual display systems, image generation systems, modular cab designs, and simulator control station designs were performed and are discussed. State of the art survey data were used to synthesize a set of preliminary visual display system concepts of which five candidate display configurations were selected for further evaluation. Basic display concepts incorporated in these configurations included: real image projection, using either periscopes, fiber optic bundles, or scanned laser optics; and virtual imaging with helmet mounted displays. These display concepts were integrated in the study with a simulator cab concept employing a modular base for aircraft controls, crew seating, and instrumentation (or other) displays. A simple concept to induce vibration in the various modules was developed and is described. Results of evaluations and trade offs related to the candidate system concepts are given, along with a suggested weighting scheme for numerically comparing visual system performance characteristics.
A visual servo-based teleoperation robot system for closed diaphyseal fracture reduction.
Li, Changsheng; Wang, Tianmiao; Hu, Lei; Zhang, Lihai; Du, Hailong; Zhao, Lu; Wang, Lifeng; Tang, Peifu
2015-09-01
Common fracture treatments include open reduction and intramedullary nailing technology. However, these methods have disadvantages such as intraoperative X-ray radiation, delayed union or nonunion and postoperative rotation. Robots provide a novel solution to the aforementioned problems while posing new challenges. Against this scientific background, we develop a visual servo-based teleoperation robot system. In this article, we present a robot system, analyze the visual servo-based control system in detail and develop path planning for fracture reduction, inverse kinematics, and output forces of the reduction mechanism. A series of experimental tests is conducted on a bone model and an animal bone. The experimental results demonstrate the feasibility of the robot system. The robot system uses preoperative computed tomography data to realize high precision and perform minimally invasive teleoperation for fracture reduction via the visual servo-based control system while protecting surgeons from radiation. © IMechE 2015.
NASA Astrophysics Data System (ADS)
Akpojotor, Godfrey; Ehwerhemuepha, Louis; Amromanoh, Ogheneriobororue
2013-03-01
The presence of physical systems whose characteristics change in a seemingly erratic manner gives rise to the study of chaotic systems. The characteristics of these systems are due to their hypersensitivity to changes in initial conditions. In order to understand chaotic systems, some sort of simulation and visualization is pertinent. Consequently, in this work, we have simulated and graphically visualized chaos in a driven nonlinear pendulum as a means of introducing chaotic systems. The results obtained which highlight the hypersensitivity of the pendulum are used to discuss the effectiveness of teaching and learning the physics of chaotic system using Python. This study is one of the many studies under the African Computational Science and Engineering Tour Project (PASET) which is using Python to model, simulate and visualize concepts, laws and phenomena in Science and Engineering to compliment the teaching/learning of theory and experiment.
Visualizing Parallel Computer System Performance
NASA Technical Reports Server (NTRS)
Malony, Allen D.; Reed, Daniel A.
1988-01-01
Parallel computer systems are among the most complex of man's creations, making satisfactory performance characterization difficult. Despite this complexity, there are strong, indeed, almost irresistible, incentives to quantify parallel system performance using a single metric. The fallacy lies in succumbing to such temptations. A complete performance characterization requires not only an analysis of the system's constituent levels, it also requires both static and dynamic characterizations. Static or average behavior analysis may mask transients that dramatically alter system performance. Although the human visual system is remarkedly adept at interpreting and identifying anomalies in false color data, the importance of dynamic, visual scientific data presentation has only recently been recognized Large, complex parallel system pose equally vexing performance interpretation problems. Data from hardware and software performance monitors must be presented in ways that emphasize important events while eluding irrelevant details. Design approaches and tools for performance visualization are the subject of this paper.
Wei, Jyh-Da; Tsai, Ming-Hung; Lee, Gen-Cher; Huang, Jeng-Hung; Lee, Der-Tsai
2009-01-01
Algorithm visualization is a unique research topic that integrates engineering skills such as computer graphics, system programming, database management, computer networks, etc., to facilitate algorithmic researchers in testing their ideas, demonstrating new findings, and teaching algorithm design in the classroom. Within the broad applications of algorithm visualization, there still remain performance issues that deserve further research, e.g., system portability, collaboration capability, and animation effect in 3D environments. Using modern technologies of Java programming, we develop an algorithm visualization and debugging system, dubbed GeoBuilder, for geometric computing. The GeoBuilder system features Java's promising portability, engagement of collaboration in algorithm development, and automatic camera positioning for tracking 3D geometric objects. In this paper, we describe the design of the GeoBuilder system and demonstrate its applications.
Survival Processing Enhances Visual Search Efficiency.
Cho, Kit W
2018-05-01
Words rated for their survival relevance are remembered better than when rated using other well-known memory mnemonics. This finding, which is known as the survival advantage effect and has been replicated in many studies, suggests that our memory systems are molded by natural selection pressures. In two experiments, the present study used a visual search task to examine whether there is likewise a survival advantage for our visual systems. Participants rated words for their survival relevance or for their pleasantness before locating that object's picture in a search array with 8 or 16 objects. Although there was no difference in search times among the two rating scenarios when set size was 8, survival processing reduced visual search times when set size was 16. These findings reflect a search efficiency effect and suggest that similar to our memory systems, our visual systems are also tuned toward self-preservation.
The economics of motion perception and invariants of visual sensitivity.
Gepshtein, Sergei; Tyukin, Ivan; Kubovy, Michael
2007-06-21
Neural systems face the challenge of optimizing their performance with limited resources, just as economic systems do. Here, we use tools of neoclassical economic theory to explore how a frugal visual system should use a limited number of neurons to optimize perception of motion. The theory prescribes that vision should allocate its resources to different conditions of stimulation according to the degree of balance between measurement uncertainties and stimulus uncertainties. We find that human vision approximately follows the optimal prescription. The equilibrium theory explains why human visual sensitivity is distributed the way it is and why qualitatively different regimes of apparent motion are observed at different speeds. The theory offers a new normative framework for understanding the mechanisms of visual sensitivity at the threshold of visibility and above the threshold and predicts large-scale changes in visual sensitivity in response to changes in the statistics of stimulation and system goals.
High contrast sensitivity for visually guided flight control in bumblebees.
Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie
2017-12-01
Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.
NASA Technical Reports Server (NTRS)
Kaiser, Mary K. (Inventor); Adelstein, Bernard D. (Inventor); Anderson, Mark R. (Inventor); Beutter, Brent R. (Inventor); Ahumada, Albert J., Jr. (Inventor); McCann, Robert S. (Inventor)
2014-01-01
A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).
Computer vision for general purpose visual inspection: a fuzzy logic approach
NASA Astrophysics Data System (ADS)
Chen, Y. H.
In automatic visual industrial inspection, computer vision systems have been widely used. Such systems are often application specific, and therefore require domain knowledge in order to have a successful implementation. Since visual inspection can be viewed as a decision making process, it is argued that the integration of fuzzy logic analysis and computer vision systems provides a practical approach to general purpose visual inspection applications. This paper describes the development of an integrated fuzzy-rule-based automatic visual inspection system. Domain knowledge about a particular application is represented as a set of fuzzy rules. From the status of predefined fuzzy variables, the set of fuzzy rules are defuzzified to give the inspection results. A practical application where IC marks (often in the forms of English characters and a company logo) inspection is demonstrated, which shows a more consistent result as compared to a conventional thresholding method.
Hierarchical Modelling Of Mobile, Seeing Robots
NASA Astrophysics Data System (ADS)
Luh, Cheng-Jye; Zeigler, Bernard P.
1990-03-01
This paper describes the implementation of a hierarchical robot simulation which supports the design of robots with vision and mobility. A seeing robot applies a classification expert system for visual identification of laboratory objects. The visual data acquisition algorithm used by the robot vision system has been developed to exploit multiple viewing distances and perspectives. Several different simulations have been run testing the visual logic in a laboratory environment. Much work remains to integrate the vision system with the rest of the robot system.
Hierarchical modelling of mobile, seeing robots
NASA Technical Reports Server (NTRS)
Luh, Cheng-Jye; Zeigler, Bernard P.
1990-01-01
This paper describes the implementation of a hierarchical robot simulation which supports the design of robots with vision and mobility. A seeing robot applies a classification expert system for visual identification of laboratory objects. The visual data acquisition algorithm used by the robot vision system has been developed to exploit multiple viewing distances and perspectives. Several different simulations have been run testing the visual logic in a laboratory environment. Much work remains to integrate the vision system with the rest of the robot system.
Visual monitoring of autonomous life sciences experimentation
NASA Technical Reports Server (NTRS)
Blank, G. E.; Martin, W. N.
1987-01-01
The design and implementation of a computerized visual monitoring system to aid in the monitoring and control of life sciences experiments on board a space station was investigated. A likely multiprocessor design was chosen, a plausible life science experiment with which to work was defined, the theoretical issues involved in the programming of a visual monitoring system for the experiment was considered on the multiprocessor, a system for monitoring the experiment was designed, and simulations of such a system was implemented on a network of Apollo workstations.
The eye and visual nervous system: anatomy, physiology and toxicology.
McCaa, C S
1982-01-01
The eyes are at risk to environmental injury by direct exposure to airborne pollutants, to splash injury from chemicals and to exposure via the circulatory system to numerous drugs and bloodborne toxins. In addition, drugs or toxins can destroy vision by damaging the visual nervous system. This review describes the anatomy and physiology of the eye and visual nervous system and includes a discussion of some of the more common toxins affecting vision in man. Images FIGURE 1. FIGURE 2. PMID:7084144
NASA Astrophysics Data System (ADS)
Makarov, V.; Korelin, O.; Koblyakov, D.; Kostin, S.; Komandirov, A.
2018-02-01
The article is devoted to the development of the Advanced Driver Assistance Systems (ADAS) for the GAZelle NEXT car. This project is aimed at developing a visual information system for the driver integrated into the windshield racks. The developed system implements the following functions: assistance in maneuvering and parking; Recognition of road signs; Warning the driver about the possibility of a frontal collision; Control of "blind" zones; "Transparent" vision in the windshield racks, widening the field of view, behind them; Visual and sound information about the traffic situation; Control and descent from the lane of the vehicle; Monitoring of the driver’s condition; navigation system; All-round review. The scheme of action of sensors of the developed system of visual information of the driver is provided. The moments of systems on a prototype of a vehicle are considered. Possible changes in the interior and dashboard of the car are given. The results of the implementation are aimed at the implementation of the system - improved informing of the driver about the environment and the development of an ergonomic interior for this system within the new Functional Salon of the Gazelle Next vehicle equipped with a visual information system for the driver.
Visualization and Analytics Software Tools for Peregrine System |
R is a language and environment for statistical computing and graphics. Go to the R web site for System Visualization and Analytics Software Tools for Peregrine System Learn about the available visualization for OpenGL-based applications. For more information, please go to the FastX page. ParaView An open
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.
Is orbital volume associated with eyeball and visual cortex volume in humans?
Pearce, Eiluned; Bridge, Holly
2013-01-01
Background In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. Aim To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Subjects & Methods Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (N=88), and brain and visual cortex (N=99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. Results A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes, (iii) different visual cortical areas, independently of overall brain volume. Conclusion In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices. PMID:23879766
Do Visual Illusions Probe the Visual Brain?: Illusions in Action without a Dorsal Visual Stream
ERIC Educational Resources Information Center
Coello, Yann; Danckert, James; Blangero, Annabelle; Rossetti, Yves
2007-01-01
Visual illusions have been shown to affect perceptual judgements more so than motor behaviour, which was interpreted as evidence for a functional division of labour within the visual system. The dominant perception-action theory argues that perception involves a holistic processing of visual objects or scenes, performed within the ventral,…
75 FR 53262 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
... a new Privacy Act system of records, JUSTICE/FBI- 021, the Data Integration and Visualization System... Act system of records, the Data Integration and Visualization System (DIVS), Justice/FBI-021. The... investigative mission by enabling access, search, integration, and analytics across multiple existing databases...
Age-related declines of stability in visual perceptual learning.
Chang, Li-Hung; Shibata, Kazuhisa; Andersen, George J; Sasaki, Yuka; Watanabe, Takeo
2014-12-15
One of the biggest questions in learning is how a system can resolve the plasticity and stability dilemma. Specifically, the learning system needs to have not only a high capability of learning new items (plasticity) but also a high stability to retain important items or processing in the system by preventing unimportant or irrelevant information from being learned. This dilemma should hold true for visual perceptual learning (VPL), which is defined as a long-term increase in performance on a visual task as a result of visual experience. Although it is well known that aging influences learning, the effect of aging on the stability and plasticity of the visual system is unclear. To address the question, we asked older and younger adults to perform a task while a task-irrelevant feature was merely exposed. We found that older individuals learned the task-irrelevant features that younger individuals did not learn, both the features that were sufficiently strong for younger individuals to suppress and the features that were too weak for younger individuals to learn. At the same time, there was no plasticity reduction in older individuals within the task tested. These results suggest that the older visual system is less stable to unimportant information than the younger visual system. A learning problem with older individuals may be due to a decrease in stability rather than a decrease in plasticity, at least in VPL. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mastering algebra retrains the visual system to perceive hierarchical structure in equations.
Marghetis, Tyler; Landy, David; Goldstone, Robert L
2016-01-01
Formal mathematics is a paragon of abstractness. It thus seems natural to assume that the mathematical expert should rely more on symbolic or conceptual processes, and less on perception and action. We argue instead that mathematical proficiency relies on perceptual systems that have been retrained to implement mathematical skills. Specifically, we investigated whether the visual system-in particular, object-based attention-is retrained so that parsing algebraic expressions and evaluating algebraic validity are accomplished by visual processing. Object-based attention occurs when the visual system organizes the world into discrete objects, which then guide the deployment of attention. One classic signature of object-based attention is better perceptual discrimination within, rather than between, visual objects. The current study reports that object-based attention occurs not only for simple shapes but also for symbolic mathematical elements within algebraic expressions-but only among individuals who have mastered the hierarchical syntax of algebra. Moreover, among these individuals, increased object-based attention within algebraic expressions is associated with a better ability to evaluate algebraic validity. These results suggest that, in mastering the rules of algebra, people retrain their visual system to represent and evaluate abstract mathematical structure. We thus argue that algebraic expertise involves the regimentation and reuse of evolutionarily ancient perceptual processes. Our findings implicate the visual system as central to learning and reasoning in mathematics, leading us to favor educational approaches to mathematics and related STEM fields that encourage students to adapt, not abandon, their use of perception.
NASA Technical Reports Server (NTRS)
Robbins, Woodrow E. (Editor); Fisher, Scott S. (Editor)
1989-01-01
Special attention was given to problems of stereoscopic display devices, such as CAD for enhancement of the design process in visual arts, stereo-TV improvement of remote manipulator performance, a voice-controlled stereographic video camera system, and head-mounted displays and their low-cost design alternatives. Also discussed was a novel approach to chromostereoscopic microscopy, computer-generated barrier-strip autostereography and lenticular stereograms, and parallax barrier three-dimensional TV. Additional topics include processing and user interface isssues and visualization applications, including automated analysis and fliud flow topology, optical tomographic measusrements of mixing fluids, visualization of complex data, visualization environments, and visualization management systems.
Weighted feature selection criteria for visual servoing of a telerobot
NASA Technical Reports Server (NTRS)
Feddema, John T.; Lee, C. S. G.; Mitchell, O. R.
1989-01-01
Because of the continually changing environment of a space station, visual feedback is a vital element of a telerobotic system. A real time visual servoing system would allow a telerobot to track and manipulate randomly moving objects. Methodologies for the automatic selection of image features to be used to visually control the relative position between an eye-in-hand telerobot and a known object are devised. A weighted criteria function with both image recognition and control components is used to select the combination of image features which provides the best control. Simulation and experimental results of a PUMA robot arm visually tracking a randomly moving carburetor gasket with a visual update time of 70 milliseconds are discussed.
Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J
2015-09-01
Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.
The visual system in migraine: from the bench side to the office.
Kowacs, Pedro A; Utiumi, Marco A; Piovesan, Elcio J
2015-02-01
Throughout history, migraine-associated visual symptoms have puzzled patients, doctors, and neuroscientists. The visual aspects of migraine extend far beyond the aura phenomena, and have several clinical implications. A narrative review was conducted, beginning with migraine mechanisms, then followed by pertinent aspects of the anatomy of visual pathways, clinical features, implications of the visual system on therapy, migraine on visually impaired populations, treatment of visual auras and ocular (retinal) migraine, effect of prophylactic migraine treatments on visual aura, visual symptoms induced by anti-migraine or anti-headache drugs, and differential diagnosis. A comprehensive narrative review from both basic and clinical standpoints on the visual aspects of migraine was attained; however, the results were biased to provide any useful information for the clinician. This paper achieved its goals of addressing and condensing information on the pathophysiology of the visual aspects of migraine and its clinical aspects, especially with regards to therapy, making it useful not only for those unfamiliar to the theme but to experienced physicians as well. © 2015 American Headache Society.
Five-dimensional ultrasound system for soft tissue visualization.
Deshmukh, Nishikant P; Caban, Jesus J; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M
2015-12-01
A five-dimensional ultrasound (US) system is proposed as a real-time pipeline involving fusion of 3D B-mode data with the 3D ultrasound elastography (USE) data as well as visualization of these fused data and a real-time update capability over time for each consecutive scan. 3D B-mode data assist in visualizing the anatomy of the target organ, and 3D elastography data adds strain information. We investigate the feasibility of such a system and show that an end-to-end real-time system, from acquisition to visualization, can be developed. We present a system that consists of (a) a real-time 3D elastography algorithm based on a normalized cross-correlation (NCC) computation on a GPU; (b) real-time 3D B-mode acquisition and network transfer; (c) scan conversion of 3D elastography and B-mode volumes (if acquired by 4D wobbler probe); and (d) visualization software that fuses, visualizes, and updates 3D B-mode and 3D elastography data in real time. We achieved a speed improvement of 4.45-fold for the threaded version of the NCC-based 3D USE versus the non-threaded version. The maximum speed was 79 volumes/s for 3D scan conversion. In a phantom, we validated the dimensions of a 2.2-cm-diameter sphere scan-converted to B-mode volume. Also, we validated the 5D US system visualization transfer function and detected 1- and 2-cm spherical objects (phantom lesion). Finally, we applied the system to a phantom consisting of three lesions to delineate the lesions from the surrounding background regions of the phantom. A 5D US system is achievable with real-time performance. We can distinguish between hard and soft areas in a phantom using the transfer functions.
Classroom Demonstration of the Visual Effects of Eye Diseases
Raphail, Ann-Marie; Bach, Emily C.; Hallock, Robert M.
2014-01-01
An understanding of the visual system is a fundamental aspect of many neuroscience and psychology courses. These classes often cover a variety of visual diseases that are correlated with the anatomy of the visual system, e.g., cataracts are caused by a clouding of the lens. Here, we describe an easy way to modify standard laboratory glasses/goggles to simulate the various perceptual deficits that accompany vision disorders such as astigmatism, cataracts, diabetic retinopathy, glaucoma, optic neuritis, posterior vitreous detachment, and retinitis pigmentosa. For example, when teaching about cataracts, students can put on glasses that mimic how severe cataracts affect one’s vision. Using the glasses will allow students to draw connections between the disorder, its perceptual deficits, and the underlying anatomy. We also discuss floaters in the eye and provide an easy method to allow students to detect their own floaters. Together, these demonstrations make for a more dynamic and interactive class on the visual system that will better link diseases of the eye to anatomy and perception, and allow undergraduate students to develop a better understanding of the visual system as a whole. PMID:24693262
A visualization system for CT based pulmonary fissure analysis
NASA Astrophysics Data System (ADS)
Pu, Jiantao; Zheng, Bin; Park, Sang Cheol
2009-02-01
In this study we describe a visualization system of pulmonary fissures depicted on CT images. The purpose is to provide clinicians with an intuitive perception of a patient's lung anatomy through an interactive examination of fissures, enhancing their understanding and accurate diagnosis of lung diseases. This system consists of four key components: (1) region-of-interest segmentation; (2) three-dimensional surface modeling; (3) fissure type classification; and (4) an interactive user interface, by which the extracted fissures are displayed flexibly in different space domains including image space, geometric space, and mixed space using simple toggling "on" and "off" operations. In this system, the different visualization modes allow users not only to examine the fissures themselves but also to analyze the relationship between fissures and their surrounding structures. In addition, the users can adjust thresholds interactively to visualize the fissure surface under different scanning and processing conditions. Such a visualization tool is expected to facilitate investigation of structures near the fissures and provide an efficient "visual aid" for other applications such as treatment planning and assessment of therapeutic efficacy as well as education of medical professionals.
DIA2: Web-based Cyberinfrastructure for Visual Analysis of Funding Portfolios.
Madhavan, Krishna; Elmqvist, Niklas; Vorvoreanu, Mihaela; Chen, Xin; Wong, Yuetling; Xian, Hanjun; Dong, Zhihua; Johri, Aditya
2014-12-01
We present a design study of the Deep Insights Anywhere, Anytime (DIA2) platform, a web-based visual analytics system that allows program managers and academic staff at the U.S. National Science Foundation to search, view, and analyze their research funding portfolio. The goal of this system is to facilitate users' understanding of both past and currently active research awards in order to make more informed decisions of their future funding. This user group is characterized by high domain expertise yet not necessarily high literacy in visualization and visual analytics-they are essentially casual experts-and thus require careful visual and information design, including adhering to user experience standards, providing a self-instructive interface, and progressively refining visualizations to minimize complexity. We discuss the challenges of designing a system for casual experts and highlight how we addressed this issue by modeling the organizational structure and workflows of the NSF within our system. We discuss each stage of the design process, starting with formative interviews, prototypes, and finally live deployments and evaluation with stakeholders.
Deep hierarchies in the primate visual cortex: what can we learn for computer vision?
Krüger, Norbert; Janssen, Peter; Kalkan, Sinan; Lappe, Markus; Leonardis, Ales; Piater, Justus; Rodríguez-Sánchez, Antonio J; Wiskott, Laurenz
2013-08-01
Computational modeling of the primate visual system yields insights of potential relevance to some of the challenges that computer vision is facing, such as object recognition and categorization, motion detection and activity recognition, or vision-based navigation and manipulation. This paper reviews some functional principles and structures that are generally thought to underlie the primate visual cortex, and attempts to extract biological principles that could further advance computer vision research. Organized for a computer vision audience, we present functional principles of the processing hierarchies present in the primate visual system considering recent discoveries in neurophysiology. The hierarchical processing in the primate visual system is characterized by a sequence of different levels of processing (on the order of 10) that constitute a deep hierarchy in contrast to the flat vision architectures predominantly used in today's mainstream computer vision. We hope that the functional description of the deep hierarchies realized in the primate visual system provides valuable insights for the design of computer vision algorithms, fostering increasingly productive interaction between biological and computer vision research.
Oculomotor guidance and capture by irrelevant faces.
Devue, Christel; Belopolsky, Artem V; Theeuwes, Jan
2012-01-01
Even though it is generally agreed that face stimuli constitute a special class of stimuli, which are treated preferentially by our visual system, it remains unclear whether faces can capture attention in a stimulus-driven manner. Moreover, there is a long-standing debate regarding the mechanism underlying the preferential bias of selecting faces. Some claim that faces constitute a set of special low-level features to which our visual system is tuned; others claim that the visual system is capable of extracting the meaning of faces very rapidly, driving attentional selection. Those debates continue because many studies contain methodological peculiarities and manipulations that prevent a definitive conclusion. Here, we present a new visual search task in which observers had to make a saccade to a uniquely colored circle while completely irrelevant objects were also present in the visual field. The results indicate that faces capture and guide the eyes more than other animated objects and that our visual system is not only tuned to the low-level features that make up a face but also to its meaning.
Perception and Attention for Visualization
ERIC Educational Resources Information Center
Haroz, Steve
2013-01-01
This work examines how a better understanding of visual perception and attention can impact visualization design. In a collection of studies, I explore how different levels of the visual system can measurably affect a variety of visualization metrics. The results show that expert preference, user performance, and even computational performance are…
ERIC Educational Resources Information Center
Rodriguez, Lulu; Dimitrova, Daniela V.
2011-01-01
While framing research has centered mostly on the evaluations of media texts, visual news discourse has remained relatively unexamined. This study surveys the visual framing techniques and methods employed in previous studies and proposes a four-tiered model of identifying and analyzing visual frames: (1) visuals as denotative systems, (2) visuals…
The case against specialized visual-spatial short-term memory.
Morey, Candice C
2018-05-24
The dominant paradigm for understanding working memory, or the combination of the perceptual, attentional, and mnemonic processes needed for thinking, subdivides short-term memory (STM) according to whether memoranda are encoded in aural-verbal or visual formats. This traditional dissociation has been supported by examples of neuropsychological patients who seem to selectively lack STM for either aural-verbal, visual, or spatial memoranda, and by experimental research using dual-task methods. Though this evidence is the foundation of assumptions of modular STM systems, the case it makes for a specialized visual STM system is surprisingly weak. I identify the key evidence supporting a distinct verbal STM system-patients with apparent selective damage to verbal STM and the resilience of verbal short-term memories to general dual-task interference-and apply these benchmarks to neuropsychological and experimental investigations of visual-spatial STM. Contrary to the evidence on verbal STM, patients with apparent visual or spatial STM deficits tend to experience a wide range of additional deficits, making it difficult to conclude that a distinct short-term store was damaged. Consistently with this, a meta-analysis of dual-task visual-spatial STM research shows that robust dual-task costs are consistently observed regardless of the domain or sensory code of the secondary task. Together, this evidence suggests that positing a specialized visual STM system is not necessary. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Demir, I.
2014-12-01
Recent developments in internet technologies make it possible to manage and visualize large data on the web. Novel visualization techniques and interactive user interfaces allow users to create realistic environments, and interact with data to gain insight from simulations and environmental observations. The hydrological simulation system is a web-based 3D interactive learning environment for teaching hydrological processes and concepts. The simulation systems provides a visually striking platform with realistic terrain information, and water simulation. Students can create or load predefined scenarios, control environmental parameters, and evaluate environmental mitigation alternatives. The web-based simulation system provides an environment for students to learn about the hydrological processes (e.g. flooding and flood damage), and effects of development and human activity in the floodplain. The system utilizes latest web technologies and graphics processing unit (GPU) for water simulation and object collisions on the terrain. Users can access the system in three visualization modes including virtual reality, augmented reality, and immersive reality using heads-up display. The system provides various scenarios customized to fit the age and education level of various users. This presentation provides an overview of the web-based flood simulation system, and demonstrates the capabilities of the system for various visualization and interaction modes.
Semantics of the visual environment encoded in parahippocampal cortex
Bonner, Michael F.; Price, Amy Rose; Peelle, Jonathan E.; Grossman, Murray
2016-01-01
Semantic representations capture the statistics of experience and store this information in memory. A fundamental component of this memory system is knowledge of the visual environment, including knowledge of objects and their associations. Visual semantic information underlies a range of behaviors, from perceptual categorization to cognitive processes such as language and reasoning. Here we examine the neuroanatomic system that encodes visual semantics. Across three experiments, we found converging evidence indicating that knowledge of verbally mediated visual concepts relies on information encoded in a region of the ventral-medial temporal lobe centered on parahippocampal cortex. In an fMRI study, this region was strongly engaged by the processing of concepts relying on visual knowledge but not by concepts relying on other sensory modalities. In a study of patients with the semantic variant of primary progressive aphasia (semantic dementia), atrophy that encompassed this region was associated with a specific impairment in verbally mediated visual semantic knowledge. Finally, in a structural study of healthy adults from the fMRI experiment, gray matter density in this region related to individual variability in the processing of visual concepts. The anatomic location of these findings aligns with recent work linking the ventral-medial temporal lobe with high-level visual representation, contextual associations, and reasoning through imagination. Together this work suggests a critical role for parahippocampal cortex in linking the visual environment with knowledge systems in the human brain. PMID:26679216
Semantics of the Visual Environment Encoded in Parahippocampal Cortex.
Bonner, Michael F; Price, Amy Rose; Peelle, Jonathan E; Grossman, Murray
2016-03-01
Semantic representations capture the statistics of experience and store this information in memory. A fundamental component of this memory system is knowledge of the visual environment, including knowledge of objects and their associations. Visual semantic information underlies a range of behaviors, from perceptual categorization to cognitive processes such as language and reasoning. Here we examine the neuroanatomic system that encodes visual semantics. Across three experiments, we found converging evidence indicating that knowledge of verbally mediated visual concepts relies on information encoded in a region of the ventral-medial temporal lobe centered on parahippocampal cortex. In an fMRI study, this region was strongly engaged by the processing of concepts relying on visual knowledge but not by concepts relying on other sensory modalities. In a study of patients with the semantic variant of primary progressive aphasia (semantic dementia), atrophy that encompassed this region was associated with a specific impairment in verbally mediated visual semantic knowledge. Finally, in a structural study of healthy adults from the fMRI experiment, gray matter density in this region related to individual variability in the processing of visual concepts. The anatomic location of these findings aligns with recent work linking the ventral-medial temporal lobe with high-level visual representation, contextual associations, and reasoning through imagination. Together, this work suggests a critical role for parahippocampal cortex in linking the visual environment with knowledge systems in the human brain.
A massively asynchronous, parallel brain
Zeki, Semir
2015-01-01
Whether the visual brain uses a parallel or a serial, hierarchical, strategy to process visual signals, the end result appears to be that different attributes of the visual scene are perceived asynchronously—with colour leading form (orientation) by 40 ms and direction of motion by about 80 ms. Whatever the neural root of this asynchrony, it creates a problem that has not been properly addressed, namely how visual attributes that are perceived asynchronously over brief time windows after stimulus onset are bound together in the longer term to give us a unified experience of the visual world, in which all attributes are apparently seen in perfect registration. In this review, I suggest that there is no central neural clock in the (visual) brain that synchronizes the activity of different processing systems. More likely, activity in each of the parallel processing-perceptual systems of the visual brain is reset independently, making of the brain a massively asynchronous organ, just like the new generation of more efficient computers promise to be. Given the asynchronous operations of the brain, it is likely that the results of activities in the different processing-perceptual systems are not bound by physiological interactions between cells in the specialized visual areas, but post-perceptually, outside the visual brain. PMID:25823871
Design and implementation of visualization methods for the CHANGES Spatial Decision Support System
NASA Astrophysics Data System (ADS)
Cristal, Irina; van Westen, Cees; Bakker, Wim; Greiving, Stefan
2014-05-01
The CHANGES Spatial Decision Support System (SDSS) is a web-based system aimed for risk assessment and the evaluation of optimal risk reduction alternatives at local level as a decision support tool in long-term natural risk management. The SDSS use multidimensional information, integrating thematic, spatial, temporal and documentary data. The role of visualization in this context becomes of vital importance for efficiently representing each dimension. This multidimensional aspect of the required for the system risk information, combined with the diversity of the end-users imposes the use of sophisticated visualization methods and tools. The key goal of the present work is to exploit efficiently the large amount of data in relation to the needs of the end-user, utilizing proper visualization techniques. Three main tasks have been accomplished for this purpose: categorization of the end-users, the definition of system's modules and the data definition. The graphical representation of the data and the visualization tools were designed to be relevant to the data type and the purpose of the analysis. Depending on the end-users category, each user should have access to different modules of the system and thus, to the proper visualization environment. The technologies used for the development of the visualization component combine the latest and most innovative open source JavaScript frameworks, such as OpenLayers 2.13.1, ExtJS 4 and GeoExt 2. Moreover, the model-view-controller (MVC) pattern is used in order to ensure flexibility of the system at the implementation level. Using the above technologies, the visualization techniques implemented so far offer interactive map navigation, querying and comparison tools. The map comparison tools are of great importance within the SDSS and include the following: swiping tool for comparison of different data of the same location; raster subtraction for comparison of the same phenomena varying in time; linked views for comparison of data from different locations and a time slider tool for monitoring changes in spatio-temporal data. All these techniques are part of the interactive interface of the system and make use of spatial and spatio-temporal data. Further significant aspects of the visualization component include conventional cartographic techniques and visualization of non-spatial data. The main expectation from the present work is to offer efficient visualization of risk-related data in order to facilitate the decision making process, which is the final purpose of the CHANGES SDSS. This work is part of the "CHANGES" project, funded by the European Community's 7th Framework Programme.
VisualEyes: a modular software system for oculomotor experimentation.
Guo, Yi; Kim, Eun H; Kim, Eun; Alvarez, Tara; Alvarez, Tara L
2011-03-25
Eye movement studies have provided a strong foundation forming an understanding of how the brain acquires visual information in both the normal and dysfunctional brain.(1) However, development of a platform to stimulate and store eye movements can require substantial programming, time and costs. Many systems do not offer the flexibility to program numerous stimuli for a variety of experimental needs. However, the VisualEyes System has a flexible architecture, allowing the operator to choose any background and foreground stimulus, program one or two screens for tandem or opposing eye movements and stimulate the left and right eye independently. This system can significantly reduce the programming development time needed to conduct an oculomotor study. The VisualEyes System will be discussed in three parts: 1) the oculomotor recording device to acquire eye movement responses, 2) the VisualEyes software written in LabView, to generate an array of stimuli and store responses as text files and 3) offline data analysis. Eye movements can be recorded by several types of instrumentation such as: a limbus tracking system, a sclera search coil, or a video image system. Typical eye movement stimuli such as saccadic steps, vergent ramps and vergent steps with the corresponding responses will be shown. In this video report, we demonstrate the flexibility of a system to create numerous visual stimuli and record eye movements that can be utilized by basic scientists and clinicians to study healthy as well as clinical populations.
A WebGIS-based system for analyzing and visualizing air quality data for Shanghai Municipality
NASA Astrophysics Data System (ADS)
Wang, Manyi; Liu, Chaoshun; Gao, Wei
2014-10-01
An online visual analytical system based on Java Web and WebGIS for air quality data for Shanghai Municipality was designed and implemented to quantitatively analyze and qualitatively visualize air quality data. By analyzing the architecture of WebGIS and Java Web, we firstly designed the overall scheme for system architecture, then put forward the software and hardware environment and also determined the main function modules for the system. The visual system was ultimately established with the DIV + CSS layout method combined with JSP, JavaScript, and some other computer programming languages based on the Java programming environment. Moreover, Struts, Spring, and Hibernate frameworks (SSH) were integrated in the system for the purpose of easy maintenance and expansion. To provide mapping service and spatial analysis functions, we selected ArcGIS for Server as the GIS server. We also used Oracle database and ESRI file geodatabase to store spatial data and non-spatial data in order to ensure the data security. In addition, the response data from the Web server are resampled to implement rapid visualization through the browser. The experimental successes indicate that this system can quickly respond to user's requests, and efficiently return the accurate processing results.
He, Fu-Liang; Wang, Lei; Zhao, Hong-Wei; Fan, Zhen-Hua; Zhao, Meng-Fei; Dai, Shan; Yue, Zhen-Dong; Liu, Fu-Quan
2015-02-28
To evaluate the feasibility of transjugular intrahepatic portosystemic shunt (TIPS) for severe jaundice secondary to acute Budd-Chiari syndrome (BCS). From February 2009 to March 2013, 37 patients with severe jaundice secondary to acute BCS were treated. Sixteen patients without hepatic venule, hepatic veins (HV) obstruction underwent percutaneous angioplasty of the inferior vena cava (IVC) and/or HVs. Twenty-one patients with HV occlusion underwent TIPS. Serum bilirubin, liver function, demographic data and operative data of the two groups of patients were analyzed. Twenty-one patients underwent TIPS and the technical success rate was 100%, with no technical complications. Sixteen patients underwent recanalization of the IVC and/or HVs and the technical success rate was 100%. The mean procedure time for TIPS was 84.0±12.11 min and angioplasty was 44.11±5.12 min (P<0.01). The mean portosystemic pressure in the TIPS group decreased significantly from 40.50±4.32 to 16.05±3.50 mmHg (P<0.01). The mean portosystemic pressure gradient decreased significantly from 33.60±2.62 to 7.30±2.21 mmHg (P<0.01). At 8 wk after the procedures, in the TIPS group, total bilirubin (TBIL) decreased significantly from 266.24±122.03 before surgery to 40.11±3.52 μmol/L (P<0.01) and direct bilirubin (DBIL) decreased significantly from 194.22±69.82 μmol/L to 29.82±3.10 μmol/L (P<0.01). In the angioplasty group, bilirubin returned to the normal range, with TBIL decreased significantly from 258.22±72.71 μmol/L to 13.33±3.54 μmol/L (P<0.01) and DBIL from 175.08±39.27 to 4.03±1.74 μmol/L (P<0.01). Liver function improved faster than TBIL. After 2 wk, in the TIPS group, alanine aminotransferase (ALT) decreased significantly from 50.33±40.61 U/L to 28.67±7.02 U/L (P<0.01) and aspartate aminotransferase (AST) from 49.46±34.33 U/L to 26.89±8.68 U/L (P<0.01). In the angioplasty group, ALT decreased significantly from 51.56±27.90 to 14.22±2.59 μmol/L (P<0.01) and AST from 60.66±39.89 μmol/L to 8.18±1.89 μmol/L (P<0.01). After mean follow-up of 12.6 mo, there was no recurrence of jaundice in either group. Severe jaundice is not a contraindication for TIPS in patients with acute BCS and TIPS is appropriate for severe jaundice due to BCS.
Robot Evolutionary Localization Based on Attentive Visual Short-Term Memory
Vega, Julio; Perdices, Eduardo; Cañas, José M.
2013-01-01
Cameras are one of the most relevant sensors in autonomous robots. However, two of their challenges are to extract useful information from captured images, and to manage the small field of view of regular cameras. This paper proposes implementing a dynamic visual memory to store the information gathered from a moving camera on board a robot, followed by an attention system to choose where to look with this mobile camera, and a visual localization algorithm that incorporates this visual memory. The visual memory is a collection of relevant task-oriented objects and 3D segments, and its scope is wider than the current camera field of view. The attention module takes into account the need to reobserve objects in the visual memory and the need to explore new areas. The visual memory is useful also in localization tasks, as it provides more information about robot surroundings than the current instantaneous image. This visual system is intended as underlying technology for service robot applications in real people's homes. Several experiments have been carried out, both with simulated and real Pioneer and Nao robots, to validate the system and each of its components in office scenarios. PMID:23337333
Transformation of an uncertain video search pipeline to a sketch-based visual analytics loop.
Legg, Philip A; Chung, David H S; Parry, Matthew L; Bown, Rhodri; Jones, Mark W; Griffiths, Iwan W; Chen, Min
2013-12-01
Traditional sketch-based image or video search systems rely on machine learning concepts as their core technology. However, in many applications, machine learning alone is impractical since videos may not be semantically annotated sufficiently, there may be a lack of suitable training data, and the search requirements of the user may frequently change for different tasks. In this work, we develop a visual analytics systems that overcomes the shortcomings of the traditional approach. We make use of a sketch-based interface to enable users to specify search requirement in a flexible manner without depending on semantic annotation. We employ active machine learning to train different analytical models for different types of search requirements. We use visualization to facilitate knowledge discovery at the different stages of visual analytics. This includes visualizing the parameter space of the trained model, visualizing the search space to support interactive browsing, visualizing candidature search results to support rapid interaction for active learning while minimizing watching videos, and visualizing aggregated information of the search results. We demonstrate the system for searching spatiotemporal attributes from sports video to identify key instances of the team and player performance.
2013-09-01
existing MR scanning systems providing the ability to visualize structures that are impossible with current methods . Using techniques to concurrently...and unique system for analysis of affected brain regions and coupled with other imaging techniques and molecular measurements holds significant...scanning systems providing the ability to visualize structures that are impossible with current methods . Using techniques to concurrently stain
Xia, Jing; Zhang, Wei; Jiang, Yizhou; Li, You; Chen, Qi
2018-05-16
Practice and experiences gradually shape the central nervous system, from the synaptic level to large-scale neural networks. In natural multisensory environment, even when inundated by streams of information from multiple sensory modalities, our brain does not give equal weight to different modalities. Rather, visual information more frequently receives preferential processing and eventually dominates consciousness and behavior, i.e., visual dominance. It remains unknown, however, the supra-modal and modality-specific practice effect during cross-modal selective attention, and moreover whether the practice effect shows similar modality preferences as the visual dominance effect in the multisensory environment. To answer the above two questions, we adopted a cross-modal selective attention paradigm in conjunction with the hybrid fMRI design. Behaviorally, visual performance significantly improved while auditory performance remained constant with practice, indicating that visual attention more flexibly adapted behavior with practice than auditory attention. At the neural level, the practice effect was associated with decreasing neural activity in the frontoparietal executive network and increasing activity in the default mode network, which occurred independently of the modality attended, i.e., the supra-modal mechanisms. On the other hand, functional decoupling between the auditory and the visual system was observed with the progress of practice, which varied as a function of the modality attended. The auditory system was functionally decoupled with both the dorsal and ventral visual stream during auditory attention while was decoupled only with the ventral visual stream during visual attention. To efficiently suppress the irrelevant visual information with practice, auditory attention needs to additionally decouple the auditory system from the dorsal visual stream. The modality-specific mechanisms, together with the behavioral effect, thus support the visual dominance model in terms of the practice effect during cross-modal selective attention. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Anezaki, Takashi; Wakitani, Kouichi; Nakamura, Masatoshi; Kubo, Hiroyasu
Because visual inspection systems are difficult to tune, they create many problems for the kaizen process. This results in increased development costs and time to assure that the inspection systems function properly. In order to improve inspection system development, we designed an easy-tuning system called a “Program-less” visual inspection system. The ROI macro command which consisted of eight kinds of shape recognition macro commands and decision, operation, control commands was built. Furthermore, the macro command editing executive system was developed by the operation of only the GUI without editing source program. The validity of the ROI macro command was proved by the application of 488 places.
Fault-Tolerant Control For A Robotic Inspection System
NASA Technical Reports Server (NTRS)
Tso, Kam Sing
1995-01-01
Report describes first phase of continuing program of research on fault-tolerant control subsystem of telerobotic visual-inspection system. Goal of program to develop robotic system for remotely controlled visual inspection of structures in outer space.
Immunostaining to visualize murine enteric nervous system development.
Barlow-Anacker, Amanda J; Erickson, Christopher S; Epstein, Miles L; Gosain, Ankush
2015-04-29
The enteric nervous system is formed by neural crest cells that proliferate, migrate and colonize the gut. Following colonization, neural crest cells must then differentiate into neurons with markers specific for their neurotransmitter phenotype. Cholinergic neurons, a major neurotransmitter phenotype in the enteric nervous system, are identified by staining for choline acetyltransferase (ChAT), the synthesizing enzyme for acetylcholine. Historical efforts to visualize cholinergic neurons have been hampered by antibodies with differing specificities to central nervous system versus peripheral nervous system ChAT. We and others have overcome this limitation by using an antibody against placental ChAT, which recognizes both central and peripheral ChAT, to successfully visualize embryonic enteric cholinergic neurons. Additionally, we have compared this antibody to genetic reporters for ChAT and shown that the antibody is more reliable during embryogenesis. This protocol describes a technique for dissecting, fixing and immunostaining of the murine embryonic gastrointestinal tract to visualize enteric nervous system neurotransmitter expression.
Ganz, Aura; Schafer, James; Gandhi, Siddhesh; Puleo, Elaine; Wilson, Carole; Robertson, Meg
2012-01-01
We introduce PERCEPT system, an indoor navigation system for the blind and visually impaired. PERCEPT will improve the quality of life and health of the visually impaired community by enabling independent living. Using PERCEPT, blind users will have independent access to public health facilities such as clinics, hospitals, and wellness centers. Access to healthcare facilities is crucial for this population due to the multiple health conditions that they face such as diabetes and its complications. PERCEPT system trials with 24 blind and visually impaired users in a multistory building show PERCEPT system effectiveness in providing appropriate navigation instructions to these users. The uniqueness of our system is that it is affordable and that its design follows orientation and mobility principles. We hope that PERCEPT will become a standard deployed in all indoor public spaces, especially in healthcare and wellness facilities. PMID:23316225
A Spot Reminder System for the Visually Impaired Based on a Smartphone Camera
Takizawa, Hotaka; Orita, Kazunori; Aoyagi, Mayumi; Ezaki, Nobuo; Mizuno, Shinji
2017-01-01
The present paper proposes a smartphone-camera-based system to assist visually impaired users in recalling their memories related to important locations, called spots, that they visited. The memories are recorded as voice memos, which can be played back when the users return to the spots. Spot-to-spot correspondence is determined by image matching based on the scale invariant feature transform. The main contribution of the proposed system is to allow visually impaired users to associate arbitrary voice memos with arbitrary spots. The users do not need any special devices or systems except smartphones and do not need to remember the spots where the voice memos were recorded. In addition, the proposed system can identify spots in environments that are inaccessible to the global positioning system. The proposed system has been evaluated by two experiments: image matching tests and a user study. The experimental results suggested the effectiveness of the system to help visually impaired individuals, including blind individuals, recall information about regularly-visited spots. PMID:28165403
A Spot Reminder System for the Visually Impaired Based on a Smartphone Camera.
Takizawa, Hotaka; Orita, Kazunori; Aoyagi, Mayumi; Ezaki, Nobuo; Mizuno, Shinji
2017-02-04
The present paper proposes a smartphone-camera-based system to assist visually impaired users in recalling their memories related to important locations, called spots, that they visited. The memories are recorded as voice memos, which can be played back when the users return to the spots. Spot-to-spot correspondence is determined by image matching based on the scale invariant feature transform. The main contribution of the proposed system is to allow visually impaired users to associate arbitrary voice memos with arbitrary spots. The users do not need any special devices or systems except smartphones and do not need to remember the spots where the voice memos were recorded. In addition, the proposed system can identify spots in environments that are inaccessible to the global positioning system. The proposed system has been evaluated by two experiments: image matching tests and a user study. The experimental results suggested the effectiveness of the system to help visually impaired individuals, including blind individuals, recall information about regularly-visited spots.
Arcaro, Michael J; Honey, Christopher J; Mruczek, Ryan EB; Kastner, Sabine; Hasson, Uri
2015-01-01
The human visual system can be divided into over two-dozen distinct areas, each of which contains a topographic map of the visual field. A fundamental question in vision neuroscience is how the visual system integrates information from the environment across different areas. Using neuroimaging, we investigated the spatial pattern of correlated BOLD signal across eight visual areas on data collected during rest conditions and during naturalistic movie viewing. The correlation pattern between areas reflected the underlying receptive field organization with higher correlations between cortical sites containing overlapping representations of visual space. In addition, the correlation pattern reflected the underlying widespread eccentricity organization of visual cortex, in which the highest correlations were observed for cortical sites with iso-eccentricity representations including regions with non-overlapping representations of visual space. This eccentricity-based correlation pattern appears to be part of an intrinsic functional architecture that supports the integration of information across functionally specialized visual areas. DOI: http://dx.doi.org/10.7554/eLife.03952.001 PMID:25695154
Flight simulator with spaced visuals
NASA Technical Reports Server (NTRS)
Gilson, Richard D. (Inventor); Thurston, Marlin O. (Inventor); Olson, Karl W. (Inventor); Ventola, Ronald W. (Inventor)
1980-01-01
A flight simulator arrangement wherein a conventional, movable base flight trainer is combined with a visual cue display surface spaced a predetermined distance from an eye position within the trainer. Thus, three degrees of motive freedom (roll, pitch and crab) are provided for a visual proprioceptive, and vestibular cue system by the trainer while the remaining geometric visual cue image alterations are developed by a video system. A geometric approach to computing runway image eliminates a need to electronically compute trigonometric functions, while utilization of a line generator and designated vanishing point at the video system raster permits facile development of the images of the longitudinal edges of the runway.
Design of an Eye Limiting Resolution Visual System Using Commercial-Off-the-Shelf Equipment
NASA Technical Reports Server (NTRS)
Sweet, Barbara T.; Giovannetti, Dean P.
2008-01-01
A feasibility study was conducted to determine if a flight simulator with an eye-limiting resolution out-the-window (OTW) visual system could be built using commercial off-the-shelf (COTS) technology and used to evaluate the visual performance of Air Force pilots in an operations context. Results of this study demonstrate that an eye limiting OTW visual system can be built using COTS technology. Further, a series of operationally-based tasks linked to clinical vision tests can be used within the synthetic environment to demonstrate a correlation and quantify the level of correlation between vision and operational aviation performance.
Geowall: Investigations into low-cost stereo display technologies
Steinwand, Daniel R.; Davis, Brian; Weeks, Nathan
2003-01-01
Recently, the combination of new projection technology, fast, low-cost graphics cards, and Linux-powered personal computers has made it possible to provide a stereoprojection and stereoviewing system that is much more affordable than previous commercial solutions. These Geowall systems are low-cost visualization systems built with commodity off-the-shelf components, run on open-source (and other) operating systems, and using open-source applications software. In short, they are ?Beowulf-class? visualization systems that provide a cost-effective way for the U. S. Geological Survey to broaden participation in the visualization community and view stereoimagery and three-dimensional models2.
Simulating storage part of application with Simgrid
NASA Astrophysics Data System (ADS)
Wang, Cong
2017-10-01
Design of a file system simulation and visualization system, using simgrid API and visualization techniques to help users understanding and improving the file system portion of their application. The core of the simulator is the API provided by simgrid, cluefs tracks and catches the procedure of the I/O operation. Run the simulator simulating this application to generate the output visualization file, which can visualize the I/O action proportion and time series. Users can also change the parameters in the configuration file to change the parameters of the storage system such as reading and writing bandwidth, users can also adjust the storage strategy, test the performance, getting reference to be much easier to optimize the storage system. We have tested all the aspects of the simulator, the results suggest that the simulator performance can be believable.
FPV: fast protein visualization using Java 3D.
Can, Tolga; Wang, Yujun; Wang, Yuan-Fang; Su, Jianwen
2003-05-22
Many tools have been developed to visualize protein structures. Tools that have been based on Java 3D((TM)) are compatible among different systems and they can be run remotely through web browsers. However, using Java 3D for visualization has some performance issues with it. The primary concerns about molecular visualization tools based on Java 3D are in their being slow in terms of interaction speed and in their inability to load large molecules. This behavior is especially apparent when the number of atoms to be displayed is huge, or when several proteins are to be displayed simultaneously for comparison. In this paper we present techniques for organizing a Java 3D scene graph to tackle these problems. We have developed a protein visualization system based on Java 3D and these techniques. We demonstrate the effectiveness of the proposed method by comparing the visualization component of our system with two other Java 3D based molecular visualization tools. In particular, for van der Waals display mode, with the efficient organization of the scene graph, we could achieve up to eight times improvement in rendering speed and could load molecules three times as large as the previous systems could. EPV is freely available with source code at the following URL: http://www.cs.ucsb.edu/~tcan/fpv/
Tactical 3D Model Generation using Structure-From-Motion on Video from Unmanned Systems
2015-04-01
available SfM application known as VisualSFM .6,7 VisualSFM is an end-user, “off-the-shelf” implementation of SfM that is easy to configure and used for...most 3D model generation applications from imagery. While the usual interface with VisualSFM is through their graphical user interface (GUI), we will be...of our system.5 There are two types of 3D model generation available within VisualSFM ; sparse and dense reconstruction. Sparse reconstruction begins
NASA Technical Reports Server (NTRS)
Marshall, S. E.; Bernhard, R.
1984-01-01
A survey of the most widely used methods for visualizing acoustic phenomena is presented. Emphasis is placed on acoustic processes in the audible frequencies. Many visual problems are analyzed on computer graphic systems. A brief description of the current technology in computer graphics is included. The visualization technique survey will serve as basis for recommending an optimum scheme for displaying acoustic fields on computer graphic systems.
Beyond Control Panels: Direct Manipulation for Visual Analytics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Endert, Alexander; Bradel, Lauren; North, Chris
2013-07-19
Information Visualization strives to provide visual representations through which users can think about and gain insight into information. By leveraging the visual and cognitive systems of humans, complex relationships and phenomena occurring within datasets can be uncovered by exploring information visually. Interaction metaphors for such visualizations are designed to enable users direct control over the filters, queries, and other parameters controlling how the data is visually represented. Through the evolution of information visualization, more complex mathematical and data analytic models are being used to visualize relationships and patterns in data – creating the field of Visual Analytics. However, the expectationsmore » for how users interact with these visualizations has remained largely unchanged – focused primarily on the direct manipulation of parameters of the underlying mathematical models. In this article we present an opportunity to evolve the methodology for user interaction from the direct manipulation of parameters through visual control panels, to interactions designed specifically for visual analytic systems. Instead of focusing on traditional direct manipulation of mathematical parameters, the evolution of the field can be realized through direct manipulation within the visual representation – where users can not only gain insight, but also interact. This article describes future directions and research challenges that fundamentally change the meaning of direct manipulation with regards to visual analytics, advancing the Science of Interaction.« less
Analysis and Selection of a Remote Docking Simulation Visual Display System
NASA Technical Reports Server (NTRS)
Shields, N., Jr.; Fagg, M. F.
1984-01-01
The development of a remote docking simulation visual display system is examined. Video system and operator performance are discussed as well as operator command and control requirements and a design analysis of the reconfigurable work station.
Visualization and Tracking of Parallel CFD Simulations
NASA Technical Reports Server (NTRS)
Vaziri, Arsi; Kremenetsky, Mark
1995-01-01
We describe a system for interactive visualization and tracking of a 3-D unsteady computational fluid dynamics (CFD) simulation on a parallel computer. CM/AVS, a distributed, parallel implementation of a visualization environment (AVS) runs on the CM-5 parallel supercomputer. A CFD solver is run as a CM/AVS module on the CM-5. Data communication between the solver, other parallel visualization modules, and a graphics workstation, which is running AVS, are handled by CM/AVS. Partitioning of the visualization task, between CM-5 and the workstation, can be done interactively in the visual programming environment provided by AVS. Flow solver parameters can also be altered by programmable interactive widgets. This system partially removes the requirement of storing large solution files at frequent time steps, a characteristic of the traditional 'simulate (yields) store (yields) visualize' post-processing approach.
A Closed Circuit TV System for the Visually Handicapped and Prospects for Future Research.
ERIC Educational Resources Information Center
Genensky, S. M.; And Others
Some visually handicapped persons have difficulty reading or writing even with the aid of eyeglasses, but could be helped by visual aids which increase image magnification, light intensity or brightness, or some combination of these factors. The system described here uses closed circuit television (CCTV) to provide variable magnification from 1.4x…
ERIC Educational Resources Information Center
Li, Alicia
2009-01-01
At least 60% of children with disabilities have multiple disabilities including visual impairments (VI). Because the visual system is neurologically based, any problems of the neurological system will also likely affect vision. The estimated number of students with VI and additional disabilities has increased significantly over the years. Since…
75 FR 53342 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
...), Federal Bureau of Investigation (FBI), proposes to establish a new system of records, the Data Integration and Visualization System, JUSTICE/FBI-021, to support and enhance data search, integration... to develop more efficient methods to analyze FBI data. The Data Integration and Visualization System...
Visual White Matter Integrity in Schizophrenia
Butler, Pamela D.; Hoptman, Matthew J.; Nierenberg, Jay; Foxe, John J.; Javitt, Daniel C.; Lim, Kelvin O.
2007-01-01
Objective Patients with schizophrenia have visual-processing deficits. This study examines visual white matter integrity as a potential mechanism for these deficits. Method Diffusion tensor imaging was used to examine white matter integrity at four levels of the visual system in 17 patients with schizophrenia and 21 comparison subjects. The levels examined were the optic radiations, the striate cortex, the inferior parietal lobule, and the fusiform gyrus. Results Schizophrenia patients showed a significant decrease in fractional anisotropy in the optic radiations but not in any other region. Conclusions This finding indicates that white matter integrity is more impaired at initial input, rather than at higher levels of the visual system, and supports the hypothesis that visual-processing deficits occur at the early stages of processing. PMID:17074957
Development of the updated system of city underground pipelines based on Visual Studio
NASA Astrophysics Data System (ADS)
Zhang, Jianxiong; Zhu, Yun; Li, Xiangdong
2009-10-01
Our city has owned the integrated pipeline network management system with ArcGIS Engine 9.1 as the bottom development platform and with Oracle9i as basic database for storaging data. In this system, ArcGIS SDE9.1 is applied as the spatial data engine, and the system was a synthetic management software developed with Visual Studio visualization procedures development tools. As the pipeline update function of the system has the phenomenon of slower update and even sometimes the data lost, to ensure the underground pipeline data can real-time be updated conveniently and frequently, and the actuality and integrity of the underground pipeline data, we have increased a new update module in the system developed and researched by ourselves. The module has the powerful data update function, and can realize the function of inputting and outputting and rapid update volume of data. The new developed module adopts Visual Studio visualization procedures development tools, and uses access as the basic database to storage data. We can edit the graphics in AutoCAD software, and realize the database update using link between the graphics and the system. Practice shows that the update module has good compatibility with the original system, reliable and high update efficient of the database.
A Low-Cost Audio Prescription Labeling System Using RFID for Thai Visually-Impaired People.
Lertwiriyaprapa, Titipong; Fakkheow, Pirapong
2015-01-01
This research aims to develop a low-cost audio prescription labeling (APL) system for visually-impaired people by using the RFID system. The developed APL system includes the APL machine and APL software. The APL machine is for visually-impaired people while APL software allows caregivers to record all important information into the APL machine. The main objective of the development of the APL machine is to reduce costs and size by designing all of the electronic devices to fit into one print circuit board. Also, it is designed so that it is easy to use and can become an electronic aid for daily living. The developed APL software is based on Java and MySQL, both of which can operate on various operating platforms and are easy to develop as commercial software. The developed APL system was first evaluated by 5 experts. The APL system was also evaluated by 50 actual visually-impaired people (30 elders and 20 blind individuals) and 20 caregivers, pharmacists and nurses. After using the APL system, evaluations were carried out, and it can be concluded from the evaluation results that this proposed APL system can be effectively used for helping visually-impaired people in terms of self-medication.
NASA Technical Reports Server (NTRS)
Phillips, Rachel; Madhavan, Poornima
2010-01-01
The purpose of this research was to examine the impact of environmental distractions on human trust and utilization of automation during the process of visual search. Participants performed a computer-simulated airline luggage screening task with the assistance of a 70% reliable automated decision aid (called DETECTOR) both with and without environmental distractions. The distraction was implemented as a secondary task in either a competing modality (visual) or non-competing modality (auditory). The secondary task processing code either competed with the luggage screening task (spatial code) or with the automation's textual directives (verbal code). We measured participants' system trust, perceived reliability of the system (when a target weapon was present and absent), compliance, reliance, and confidence when agreeing and disagreeing with the system under both distracted and undistracted conditions. Results revealed that system trust was lower in the visual-spatial and auditory-verbal conditions than in the visual-verbal and auditory-spatial conditions. Perceived reliability of the system (when the target was present) was significantly higher when the secondary task was visual rather than auditory. Compliance with the aid increased in all conditions except for the auditory-verbal condition, where it decreased. Similar to the pattern for trust, reliance on the automation was lower in the visual-spatial and auditory-verbal conditions than in the visual-verbal and auditory-spatial conditions. Confidence when agreeing with the system decreased with the addition of any kind of distraction; however, confidence when disagreeing increased with the addition of an auditory secondary task but decreased with the addition of a visual task. A model was developed to represent the research findings and demonstrate the relationship between secondary task modality, processing code, and automation use. Results suggest that the nature of environmental distractions influence interaction with automation via significant effects on trust and system utilization. These findings have implications for both automation design and operator training.
Driver Distraction Using Visual-Based Sensors and Algorithms.
Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén
2016-10-28
Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed.
Driver Distraction Using Visual-Based Sensors and Algorithms
Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén
2016-01-01
Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed. PMID:27801822
Bio-inspired display of polarization information using selected visual cues
NASA Astrophysics Data System (ADS)
Yemelyanov, Konstantin M.; Lin, Shih-Schon; Luis, William Q.; Pugh, Edward N., Jr.; Engheta, Nader
2003-12-01
For imaging systems the polarization of electromagnetic waves carries much potentially useful information about such features of the world as the surface shape, material contents, local curvature of objects, as well as about the relative locations of the source, object and imaging system. The imaging system of the human eye however, is "polarization-blind", and cannot utilize the polarization of light without the aid of an artificial, polarization-sensitive instrument. Therefore, polarization information captured by a man-made polarimetric imaging system must be displayed to a human observer in the form of visual cues that are naturally processed by the human visual system, while essentially preserving the other important non-polarization information (such as spectral and intensity information) in an image. In other words, some forms of sensory substitution are needed for representing polarization "signals" without affecting other visual information such as color and brightness. We are investigating several bio-inspired representational methodologies for mapping polarization information into visual cues readily perceived by the human visual system, and determining which mappings are most suitable for specific applications such as object detection, navigation, sensing, scene classifications, and surface deformation. The visual cues and strategies we are exploring are the use of coherently moving dots superimposed on image to represent various range of polarization signals, overlaying textures with spatial and/or temporal signatures to segregate regions of image with differing polarization, modulating luminance and/or color contrast of scenes in terms of certain aspects of polarization values, and fusing polarization images into intensity-only images. In this talk, we will present samples of our findings in this area.
VHP - An environment for the remote visualization of heuristic processes
NASA Technical Reports Server (NTRS)
Crawford, Stuart L.; Leiner, Barry M.
1991-01-01
A software system called VHP is introduced which permits the visualization of heuristic algorithms on both resident and remote hardware platforms. The VHP is based on the DCF tool for interprocess communication and is applicable to remote algorithms which can be on different types of hardware and in languages other than VHP. The VHP system is of particular interest to systems in which the visualization of remote processes is required such as robotics for telescience applications.
Patient-Clinician Encounter Information Modeling Through Web Based Intelligent 3D Visual Interface
2002-09-01
system must allow immediate access to the lab data without the need to abort the evaluation process), and (5) must apply visual thinking principles. It... Systems Research, Incorporated For a period of five (5) years after completion of the project from which the data was generated, the Government’s rights...Report 3 Sigma Systems Research, Inc. List of Figures FIGURE 1. THE TWO MAJOR ELEMENTS OF THE DEVELOPED MEDICAL DATA VISUALIZATION FRAMEWORK ..... 7
The µ-opioid system promotes visual attention to faces and eyes.
Chelnokova, Olga; Laeng, Bruno; Løseth, Guro; Eikemo, Marie; Willoch, Frode; Leknes, Siri
2016-12-01
Paying attention to others' faces and eyes is a cornerstone of human social behavior. The µ-opioid receptor (MOR) system, central to social reward-processing in rodents and primates, has been proposed to mediate the capacity for affiliative reward in humans. We assessed the role of the human MOR system in visual exploration of faces and eyes of conspecifics. Thirty healthy males received a novel, bidirectional battery of psychopharmacological treatment (an MOR agonist, a non-selective opioid antagonist, or placebo, on three separate days). Eye-movements were recorded while participants viewed facial photographs. We predicted that the MOR system would promote visual exploration of faces, and hypothesized that MOR agonism would increase, whereas antagonism decrease overt attention to the information-rich eye region. The expected linear effect of MOR manipulation on visual attention to the stimuli was observed, such that MOR agonism increased while antagonism decreased visual exploration of faces and overt attention to the eyes. The observed effects suggest that the human MOR system promotes overt visual attention to socially significant cues, in line with theories linking reward value to gaze control and target selection. Enhanced attention to others' faces and eyes represents a putative behavioral mechanism through which the human MOR system promotes social interest. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., and the Agency's Unified Visual Communications System § 1221.100 Scope. This subpart sets forth the... Unified Visual Communications System and prescribes the policy and guidelines for implementation of the...
Visualization Co-Processing of a CFD Simulation
NASA Technical Reports Server (NTRS)
Vaziri, Arsi
1999-01-01
OVERFLOW, a widely used CFD simulation code, is combined with a visualization system, pV3, to experiment with an environment for simulation/visualization co-processing on a SGI Origin 2000 computer(O2K) system. The shared memory version of the solver is used with the O2K 'pfa' preprocessor invoked to automatically discover parallelism in the source code. No other explicit parallelism is enabled. In order to study the scaling and performance of the visualization co-processing system, sample runs are made with different processor groups in the range of 1 to 254 processors. The data exchange between the visualization system and the simulation system is rapid enough for user interactivity when the problem size is small. This shared memory version of OVERFLOW, with minimal parallelization, does not scale well to an increasing number of available processors. The visualization task takes about 18 to 30% of the total processing time and does not appear to be a major contributor to the poor scaling. Improper load balancing and inter-processor communication overhead are contributors to this poor performance. Work is in progress which is aimed at obtaining improved parallel performance of the solver and removing the limitations of serial data transfer to pV3 by examining various parallelization/communication strategies, including the use of the explicit message passing.
A Global System for Transportation Simulation and Visualization in Emergency Evacuation Scenarios
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Wei; Liu, Cheng; Thomas, Neil
2015-01-01
Simulation-based studies are frequently used for evacuation planning and decision making processes. Given the transportation systems complexity and data availability, most evacuation simulation models focus on certain geographic areas. With routine improvement of OpenStreetMap road networks and LandScanTM global population distribution data, we present WWEE, a uniform system for world-wide emergency evacuation simulations. WWEE uses unified data structure for simulation inputs. It also integrates a super-node trip distribution model as the default simulation parameter to improve the system computational performance. Two levels of visualization tools are implemented for evacuation performance analysis, including link-based macroscopic visualization and vehicle-based microscopic visualization. Formore » left-hand and right-hand traffic patterns in different countries, the authors propose a mirror technique to experiment with both scenarios without significantly changing traffic simulation models. Ten cities in US, Europe, Middle East, and Asia are modeled for demonstration. With default traffic simulation models for fast and easy-to-use evacuation estimation and visualization, WWEE also retains the capability of interactive operation for users to adopt customized traffic simulation models. For the first time, WWEE provides a unified platform for global evacuation researchers to estimate and visualize their strategies performance of transportation systems under evacuation scenarios.« less
Chen, Chih-Yang; Tian, Xiaoguang; Idrees, Saad; Münch, Thomas A.
2017-01-01
Microsaccades occur during gaze fixation to correct for miniscule foveal motor errors. The mechanisms governing such fine oculomotor control are still not fully understood. In this study, we explored microsaccade control by analyzing the impacts of transient visual stimuli on these movements’ kinematics. We found that such kinematics can be altered in systematic ways depending on the timing and spatial geometry of visual transients relative to the movement goals. In two male rhesus macaques, we presented peripheral or foveal visual transients during an otherwise stable period of fixation. Such transients resulted in well-known reductions in microsaccade frequency, and our goal was to investigate whether microsaccade kinematics would additionally be altered. We found that both microsaccade timing and amplitude were modulated by the visual transients, and in predictable manners by these transients’ timing and geometry. Interestingly, modulations in the peak velocity of the same movements were not proportional to the observed amplitude modulations, suggesting a violation of the well-known “main sequence” relationship between microsaccade amplitude and peak velocity. We hypothesize that visual stimulation during movement preparation affects not only the saccadic “Go” system driving eye movements but also a “Pause” system inhibiting them. If the Pause system happens to be already turned off despite the new visual input, movement kinematics can be altered by the readout of additional visually evoked spikes in the Go system coding for the flash location. Our results demonstrate precise control over individual microscopic saccades and provide testable hypotheses for mechanisms of saccade control in general. NEW & NOTEWORTHY Microsaccadic eye movements play an important role in several aspects of visual perception and cognition. However, the mechanisms for microsaccade control are still not fully understood. We found that microsaccade kinematics can be altered in a systematic manner by visual transients, revealing a previously unappreciated and exquisite level of control by the oculomotor system of even the smallest saccades. Our results suggest precise temporal interaction between visual, motor, and inhibitory signals in microsaccade control. PMID:28202573
Hanken, Taylor; Young, Sam; Smilowitz, Karen; Chiampas, George; Waskowski, David
2016-10-01
As one of the largest marathons worldwide, the Bank of America Chicago Marathon (BACCM; Chicago, Illinois USA) accumulates high volumes of data. Race organizers and engaged agencies need the ability to access specific data in real-time. This report details a data visualization system designed for the Chicago Marathon and establishes key principles for event management data visualization. The data visualization system allows for efficient data communication among the organizing agencies of Chicago endurance events. Agencies can observe the progress of the race throughout the day and obtain needed information, such as the number and location of runners on the course and current weather conditions. Implementation of the system can reduce time-consuming, face-to-face interactions between involved agencies by having key data streams in one location, streamlining communications with the purpose of improving race logistics, as well as medical preparedness and response. Hanken T , Young S , Smilowitz K , Chiampas G , Waskowski D . Developing a data visualization system for the Bank of America Chicago Marathon (Chicago, Illinois USA). Prehosp Disaster Med. 2016;31(5):572-577.
NASA Astrophysics Data System (ADS)
Hanhart, Philippe; Ebrahimi, Touradj
2014-03-01
Crosstalk and vergence-accommodation rivalry negatively impact the quality of experience (QoE) provided by stereoscopic displays. However, exploiting visual attention and adapting the 3D rendering process on the fly can reduce these drawbacks. In this paper, we propose and evaluate two different approaches that exploit visual attention to improve 3D QoE on stereoscopic displays: an offline system, which uses a saliency map to predict gaze position, and an online system, which uses a remote eye tracking system to measure real time gaze positions. The gaze points were used in conjunction with the disparity map to extract the disparity of the object-of-interest. Horizontal image translation was performed to bring the fixated object on the screen plane. The user preference between standard 3D mode and the two proposed systems was evaluated through a subjective evaluation. Results show that exploiting visual attention significantly improves image quality and visual comfort, with a slight advantage for real time gaze determination. Depth quality is also improved, but the difference is not significant.
A review of visual memory capacity: Beyond individual items and towards structured representations
Brady, Timothy F.; Konkle, Talia; Alvarez, George A.
2012-01-01
Traditional memory research has focused on identifying separate memory systems and exploring different stages of memory processing. This approach has been valuable for establishing a taxonomy of memory systems and characterizing their function, but has been less informative about the nature of stored memory representations. Recent research on visual memory has shifted towards a representation-based emphasis, focusing on the contents of memory, and attempting to determine the format and structure of remembered information. The main thesis of this review will be that one cannot fully understand memory systems or memory processes without also determining the nature of memory representations. Nowhere is this connection more obvious than in research that attempts to measure the capacity of visual memory. We will review research on the capacity of visual working memory and visual long-term memory, highlighting recent work that emphasizes the contents of memory. This focus impacts not only how we estimate the capacity of the system - going beyond quantifying how many items can be remembered, and moving towards structured representations - but how we model memory systems and memory processes. PMID:21617025
A neural-visualization IDS for honeynet data.
Herrero, Álvaro; Zurutuza, Urko; Corchado, Emilio
2012-04-01
Neural intelligent systems can provide a visualization of the network traffic for security staff, in order to reduce the widely known high false-positive rate associated with misuse-based Intrusion Detection Systems (IDSs). Unlike previous work, this study proposes an unsupervised neural models that generate an intuitive visualization of the captured traffic, rather than network statistics. These snapshots of network events are immensely useful for security personnel that monitor network behavior. The system is based on the use of different neural projection and unsupervised methods for the visual inspection of honeypot data, and may be seen as a complementary network security tool that sheds light on internal data structures through visual inspection of the traffic itself. Furthermore, it is intended to facilitate verification and assessment of Snort performance (a well-known and widely-used misuse-based IDS), through the visualization of attack patterns. Empirical verification and comparison of the proposed projection methods are performed in a real domain, where two different case studies are defined and analyzed.
Value-driven attentional capture in the auditory domain.
Anderson, Brian A
2016-01-01
It is now well established that the visual attention system is shaped by reward learning. When visual features are associated with a reward outcome, they acquire high priority and can automatically capture visual attention. To date, evidence for value-driven attentional capture has been limited entirely to the visual system. In the present study, I demonstrate that previously reward-associated sounds also capture attention, interfering more strongly with the performance of a visual task. This finding suggests that value-driven attention reflects a broad principle of information processing that can be extended to other sensory modalities and that value-driven attention can bias cross-modal stimulus competition.
Market basket analysis visualization on a spherical surface
NASA Astrophysics Data System (ADS)
Hao, Ming C.; Hsu, Meichun; Dayal, Umeshwar; Wei, Shu F.; Sprenger, Thomas; Holenstein, Thomas
2001-05-01
This paper discusses the visualization of the relationships in e-commerce transactions. To date, many practical research projects have shown the usefulness of a physics-based mass- spring technique to layout data items with close relationships on a graph. We describe a market basket analysis visualization system using this technique. This system is described as the following: (1) integrates a physics-based engine into a visual data mining platform; (2) use a 3D spherical surface to visualize the cluster of related data items; and (3) for large volumes of transactions, uses hidden structures to unclutter the display. Several examples of market basket analysis are also provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, Blake; Gotseff, Peter; Giraldez, Julieta
Continued deployment of renewable and distributed energy resources is fundamentally changing the way that electric distribution systems are controlled and operated; more sophisticated active system control and greater situational awareness are needed. Real-time measurements and distribution system state estimation (DSSE) techniques enable more sophisticated system control and, when combined with visualization applications, greater situational awareness. This paper presents a novel demonstration of a high-speed, real-time DSSE platform and related control and visualization functionalities, implemented using existing open-source software and distribution system monitoring hardware. Live scrolling strip charts of meter data and intuitive annotated map visualizations of the entire state (obtainedmore » via DSSE) of a real-world distribution circuit are shown. The DSSE implementation is validated to demonstrate provision of accurate voltage data. This platform allows for enhanced control and situational awareness using only a minimum quantity of distribution system measurement units and modest data and software infrastructure.« less
Touch to see: neuropsychological evidence of a sensory mirror system for touch.
Bolognini, Nadia; Olgiati, Elena; Xaiz, Annalisa; Posteraro, Lucio; Ferraro, Francesco; Maravita, Angelo
2012-09-01
The observation of touch can be grounded in the activation of brain areas underpinning direct tactile experience, namely the somatosensory cortices. What is the behavioral impact of such a mirror sensory activity on visual perception? To address this issue, we investigated the causal interplay between observed and felt touch in right brain-damaged patients, as a function of their underlying damaged visual and/or tactile modalities. Patients and healthy controls underwent a detection task, comprising visual stimuli depicting touches or without a tactile component. Touch and No-touch stimuli were presented in egocentric or allocentric perspectives. Seeing touches, regardless of the viewing perspective, differently affects visual perception depending on which sensory modality is damaged: In patients with a selective visual deficit, but without any tactile defect, the sight of touch improves the visual impairment; this effect is associated with a lesion to the supramarginal gyrus. In patients with a tactile deficit, but intact visual perception, the sight of touch disrupts visual processing, inducing a visual extinction-like phenomenon. This disruptive effect is associated with the damage of the postcentral gyrus. Hence, a damage to the somatosensory system can lead to a dysfunctional visual processing, and an intact somatosensory processing can aid visual perception.
How Information Visualization Systems Change Users' Understandings of Complex Data
ERIC Educational Resources Information Center
Allendoerfer, Kenneth Robert
2009-01-01
User-centered evaluations of information systems often focus on the usability of the system rather its usefulness. This study examined how a using an interactive knowledge-domain visualization (KDV) system affected users' understanding of a domain. Interactive KDVs allow users to create graphical representations of domains that depict important…
Effect of eye position during human visual-vestibular integration of heading perception.
Crane, Benjamin T
2017-09-01
Visual and inertial stimuli provide heading discrimination cues. Integration of these multisensory stimuli has been demonstrated to depend on their relative reliability. However, the reference frame of visual stimuli is eye centered while inertia is head centered, and it remains unclear how these are reconciled with combined stimuli. Seven human subjects completed a heading discrimination task consisting of a 2-s translation with a peak velocity of 16 cm/s. Eye position was varied between 0° and ±25° left/right. Experiments were done with inertial motion, visual motion, or a combined visual-inertial motion. Visual motion coherence varied between 35% and 100%. Subjects reported whether their perceived heading was left or right of the midline in a forced-choice task. With the inertial stimulus the eye position had an effect such that the point of subjective equality (PSE) shifted 4.6 ± 2.4° in the gaze direction. With the visual stimulus the PSE shift was 10.2 ± 2.2° opposite the gaze direction, consistent with retinotopic coordinates. Thus with eccentric eye positions the perceived inertial and visual headings were offset ~15°. During the visual-inertial conditions the PSE varied consistently with the relative reliability of these stimuli such that at low visual coherence the PSE was similar to that of the inertial stimulus and at high coherence it was closer to the visual stimulus. On average, the inertial stimulus was weighted near Bayesian ideal predictions, but there was significant deviation from ideal in individual subjects. These findings support visual and inertial cue integration occurring in independent coordinate systems. NEW & NOTEWORTHY In multiple cortical areas visual heading is represented in retinotopic coordinates while inertial heading is in body coordinates. It remains unclear whether multisensory integration occurs in a common coordinate system. The experiments address this using a multisensory integration task with eccentric gaze positions making the effect of coordinate systems clear. The results indicate that the coordinate systems remain separate to the perceptual level and that during the multisensory task the perception depends on relative stimulus reliability. Copyright © 2017 the American Physiological Society.
Schut, Martijn J; Van der Stoep, Nathan; Postma, Albert; Van der Stigchel, Stefan
2017-06-01
To facilitate visual continuity across eye movements, the visual system must presaccadically acquire information about the future foveal image. Previous studies have indicated that visual working memory (VWM) affects saccade execution. However, the reverse relation, the effect of saccade execution on VWM load is less clear. To investigate the causal link between saccade execution and VWM, we combined a VWM task and a saccade task. Participants were instructed to remember one, two, or three shapes and performed either a No Saccade-, a Single Saccade- or a Dual (corrective) Saccade-task. The results indicate that items stored in VWM are reported less accurately if a single saccade-or a dual saccade-task is performed next to retaining items in VWM. Importantly, the loss of response accuracy for items retained in VWM by performing a saccade was similar to committing an extra item to VWM. In a second experiment, we observed no cost of executing a saccade for auditory working memory performance, indicating that executing a saccade exclusively taxes the VWM system. Our results suggest that the visual system presaccadically stores the upcoming retinal image, which has a similar VWM load as committing one extra item to memory and interferes with stored VWM content. After the saccade, the visual system can retrieve this item from VWM to evaluate saccade accuracy. Our results support the idea that VWM is a system which is directly linked to saccade execution and promotes visual continuity across saccades.
Visual color matching system based on RGB LED light source
NASA Astrophysics Data System (ADS)
Sun, Lei; Huang, Qingmei; Feng, Chen; Li, Wei; Wang, Chaofeng
2018-01-01
In order to study the property and performance of LED as RGB primary color light sources on color mixture in visual psychophysical experiments, and to find out the difference between LED light source and traditional light source, a visual color matching experiment system based on LED light sources as RGB primary colors has been built. By simulating traditional experiment of metameric color matching in CIE 1931 RGB color system, it can be used for visual color matching experiments to obtain a set of the spectral tristimulus values which we often call color-matching functions (CMFs). This system consists of three parts: a monochromatic light part using blazed grating, a light mixing part where the summation of 3 LED illuminations are to be visually matched with a monochromatic illumination, and a visual observation part. The three narrow band LEDs used have dominant wavelengths of 640 nm (red), 522 nm (green) and 458 nm (blue) respectively and their intensities can be controlled independently. After the calibration of wavelength and luminance of LED sources with a spectrophotometer, a series of visual color matching experiments have been carried out by 5 observers. The results are compared with those from CIE 1931 RGB color system, and have been used to compute an average locus for the spectral colors in the color triangle, with white at the center. It has been shown that the use of LED is feasible and has the advantages of easy control, good stability and low cost.
Mehler, Bruce; Kidd, David; Reimer, Bryan; Reagan, Ian; Dobres, Jonathan; McCartt, Anne
2016-03-01
One purpose of integrating voice interfaces into embedded vehicle systems is to reduce drivers' visual and manual distractions with 'infotainment' technologies. However, there is scant research on actual benefits in production vehicles or how different interface designs affect attentional demands. Driving performance, visual engagement, and indices of workload (heart rate, skin conductance, subjective ratings) were assessed in 80 drivers randomly assigned to drive a 2013 Chevrolet Equinox or Volvo XC60. The Chevrolet MyLink system allowed completing tasks with one voice command, while the Volvo Sensus required multiple commands to navigate the menu structure. When calling a phone contact, both voice systems reduced visual demand relative to the visual-manual interfaces, with reductions for drivers in the Equinox being greater. The Equinox 'one-shot' voice command showed advantages during contact calling but had significantly higher error rates than Sensus during destination address entry. For both secondary tasks, neither voice interface entirely eliminated visual demand. Practitioner Summary: The findings reinforce the observation that most, if not all, automotive auditory-vocal interfaces are multi-modal interfaces in which the full range of potential demands (auditory, vocal, visual, manipulative, cognitive, tactile, etc.) need to be considered in developing optimal implementations and evaluating drivers' interaction with the systems. Social Media: In-vehicle voice-interfaces can reduce visual demand but do not eliminate it and all types of demand need to be taken into account in a comprehensive evaluation.
VisFlow - Web-based Visualization Framework for Tabular Data with a Subset Flow Model.
Yu, Bowen; Silva, Claudio T
2017-01-01
Data flow systems allow the user to design a flow diagram that specifies the relations between system components which process, filter or visually present the data. Visualization systems may benefit from user-defined data flows as an analysis typically consists of rendering multiple plots on demand and performing different types of interactive queries across coordinated views. In this paper, we propose VisFlow, a web-based visualization framework for tabular data that employs a specific type of data flow model called the subset flow model. VisFlow focuses on interactive queries within the data flow, overcoming the limitation of interactivity from past computational data flow systems. In particular, VisFlow applies embedded visualizations and supports interactive selections, brushing and linking within a visualization-oriented data flow. The model requires all data transmitted by the flow to be a data item subset (i.e. groups of table rows) of some original input table, so that rendering properties can be assigned to the subset unambiguously for tracking and comparison. VisFlow features the analysis flexibility of a flow diagram, and at the same time reduces the diagram complexity and improves usability. We demonstrate the capability of VisFlow on two case studies with domain experts on real-world datasets showing that VisFlow is capable of accomplishing a considerable set of visualization and analysis tasks. The VisFlow system is available as open source on GitHub.
Wood, Daniel K; Gu, Chao; Corneil, Brian D; Gribble, Paul L; Goodale, Melvyn A
2015-08-01
We recorded muscle activity from an upper limb muscle while human subjects reached towards peripheral targets. We tested the hypothesis that the transient visual response sweeps not only through the central nervous system, but also through the peripheral nervous system. Like the transient visual response in the central nervous system, stimulus-locked muscle responses (< 100 ms) were sensitive to stimulus contrast, and were temporally and spatially dissociable from voluntary orienting activity. Also, the arrival of visual responses reduced the variability of muscle activity by resetting the phase of ongoing low-frequency oscillations. This latter finding critically extends the emerging evidence that the feedforward visual sweep reduces neural variability via phase resetting. We conclude that, when sensory information is relevant to a particular effector, detailed information about the sensorimotor transformation, even from the earliest stages, is found in the peripheral nervous system. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Tachistoscopic exposure and masking of real three-dimensional scenes
Pothier, Stephen; Philbeck, John; Chichka, David; Gajewski, Daniel A.
2010-01-01
Although there are many well-known forms of visual cues specifying absolute and relative distance, little is known about how visual space perception develops at small temporal scales. How much time does the visual system require to extract the information in the various absolute and relative distance cues? In this article, we describe a system that may be used to address this issue by presenting brief exposures of real, three-dimensional scenes, followed by a masking stimulus. The system is composed of an electronic shutter (a liquid crystal smart window) for exposing the stimulus scene, and a liquid crystal projector coupled with an electromechanical shutter for presenting the masking stimulus. This system can be used in both full- and reduced-cue viewing conditions, under monocular and binocular viewing, and at distances limited only by the testing space. We describe a configuration that may be used for studying the microgenesis of visual space perception in the context of visually directed walking. PMID:19182129
Stereoscopic 3D entertainment and its effect on viewing comfort: comparison of children and adults.
Pölönen, Monika; Järvenpää, Toni; Bilcu, Beatrice
2013-01-01
Children's and adults' viewing comfort during stereoscopic three-dimensional film viewing and computer game playing was studied. Certain mild changes in visual function, heterophoria and near point of accommodation values, as well as eyestrain and visually induced motion sickness levels were found when single setups were compared. The viewing system had an influence on viewing comfort, in particular for eyestrain levels, but no clear difference between two- and three-dimensional systems was found. Additionally, certain mild changes in visual functions and visually induced motion sickness levels between adults and children were found. In general, all of the system-task combinations caused mild eyestrain and possible changes in visual functions, but these changes in magnitude were small. According to subjective opinions that further support these measurements, using a stereoscopic three-dimensional system for up to 2 h was acceptable for most of the users regardless of their age. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
NASA Technical Reports Server (NTRS)
Taylor, J. H.
1973-01-01
Some data on human vision, important in present and projected space activities, are presented. Visual environment and performance and structure of the visual system are also considered. Visual perception during stress is included.
Parallel computation of level set method for 500 Hz visual servo control
NASA Astrophysics Data System (ADS)
Fei, Xianfeng; Igarashi, Yasunobu; Hashimoto, Koichi
2008-11-01
We propose a 2D microorganism tracking system using a parallel level set method and a column parallel vision system (CPV). This system keeps a single microorganism in the middle of the visual field under a microscope by visual servoing an automated stage. We propose a new energy function for the level set method. This function constrains an amount of light intensity inside the detected object contour to control the number of the detected objects. This algorithm is implemented in CPV system and computational time for each frame is 2 [ms], approximately. A tracking experiment for about 25 s is demonstrated. Also we demonstrate a single paramecium can be kept tracking even if other paramecia appear in the visual field and contact with the tracked paramecium.
Dale, Naomi; Sakkalou, Elena; O'Reilly, Michelle; Springall, Clare; De Haan, Michelle; Salt, Alison
2017-07-01
To investigate how vision relates to early development by studying vision and cognition in a national cohort of 1-year-old infants with congenital disorders of the peripheral visual system and visual impairment. This was a cross-sectional observational investigation of a nationally recruited cohort of infants with 'simple' and 'complex' congenital disorders of the peripheral visual system. Entry age was 8 to 16 months. Vision level (Near Detection Scale) and non-verbal cognition (sensorimotor understanding, Reynell Zinkin Scales) were assessed. Parents completed demographic questionnaires. Of 90 infants (49 males, 41 females; mean 13mo, standard deviation [SD] 2.5mo; range 7-17mo); 25 (28%) had profound visual impairment (light perception at best) and 65 (72%) had severe visual impairment (basic 'form' vision). The Near Detection Scale correlated significantly with sensorimotor understanding developmental quotients in the 'total', 'simple', and 'complex' groups (all p<0.001). Age and vision accounted for 48% of sensorimotor understanding variance. Infants with profound visual impairment, especially in the 'complex' group with congenital disorders of the peripheral visual system with known brain involvement, showed the greatest cognitive delay. Lack of vision is associated with delayed early-object manipulative abilities and concepts; 'form' vision appeared to support early developmental advance. This paper provides baseline characteristics for cross-sectional and longitudinal follow-up investigations in progress. A methodological strength of the study was the representativeness of the cohort according to national epidemiological and population census data. © 2017 Mac Keith Press.
Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F
2007-01-01
Background Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. Results We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: . Conclusion MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine. PMID:17937818
Moore, Eider B; Poliakov, Andrew V; Lincoln, Peter; Brinkley, James F
2007-10-15
Three-dimensional (3-D) visualization of multimodality neuroimaging data provides a powerful technique for viewing the relationship between structure and function. A number of applications are available that include some aspect of 3-D visualization, including both free and commercial products. These applications range from highly specific programs for a single modality, to general purpose toolkits that include many image processing functions in addition to visualization. However, few if any of these combine both stand-alone and remote multi-modality visualization in an open source, portable and extensible tool that is easy to install and use, yet can be included as a component of a larger information system. We have developed a new open source multimodality 3-D visualization application, called MindSeer, that has these features: integrated and interactive 3-D volume and surface visualization, Java and Java3D for true cross-platform portability, one-click installation and startup, integrated data management to help organize large studies, extensibility through plugins, transparent remote visualization, and the ability to be integrated into larger information management systems. We describe the design and implementation of the system, as well as several case studies that demonstrate its utility. These case studies are available as tutorials or demos on the associated website: http://sig.biostr.washington.edu/projects/MindSeer. MindSeer provides a powerful visualization tool for multimodality neuroimaging data. Its architecture and unique features also allow it to be extended into other visualization domains within biomedicine.
Jung, Wonmo; Bülthoff, Isabelle; Armann, Regine G M
2017-11-01
The brain can only attend to a fraction of all the information that is entering the visual system at any given moment. One way of overcoming the so-called bottleneck of selective attention (e.g., J. M. Wolfe, Võ, Evans, & Greene, 2011) is to make use of redundant visual information and extract summarized statistical information of the whole visual scene. Such ensemble representation occurs for low-level features of textures or simple objects, but it has also been reported for complex high-level properties. While the visual system has, for example, been shown to compute summary representations of facial expression, gender, or identity, it is less clear whether perceptual input from all parts of the visual field contributes equally to the ensemble percept. Here we extend the line of ensemble-representation research into the realm of race and look at the possibility that ensemble perception relies on weighting visual information differently depending on its origin from either the fovea or the visual periphery. We find that observers can judge the mean race of a set of faces, similar to judgments of mean emotion from faces and ensemble representations in low-level domains of visual processing. We also find that while peripheral faces seem to be taken into account for the ensemble percept, far more weight is given to stimuli presented foveally than peripherally. Whether this precision weighting of information stems from differences in the accuracy with which the visual system processes information across the visual field or from statistical inferences about the world needs to be determined by further research.
Avilés, J M; Soler, J J
2010-01-01
We have recently published support to the hypothesis that visual systems of parents could affect nestling detectability and, consequently, influences the evolution of nestling colour designs in altricial birds. We provided comparative evidence of an adjustment of nestling colour designs to the visual system of parents that we have found in a comparative study on 22 altricial bird species. In this issue, however, Renoult et al. (J. Evol. Biol., 2009) question some of the assumptions and statistical approaches in our study. Their argumentation relied on two major points: (1) an incorrect assignment of vision system to four out of 22 sampled species in our study; and (2) the use of an incorrect approach for phylogenetic correction of the predicted associations. Here, we discuss in detail re-assignation of vision systems in that study and propose alternative interpretation for current knowledge on spectrophotometric data of avian pigments. We reanalysed the data by using phylogenetic generalized least squares analyses that account for the alluded limitations of phylogenetically independent contrasts and, in accordance with the hypothesis, confirmed a significant influence of parental visual system on gape coloration. Our results proved to be robust to the assumptions on visual system evolution for Laniidae and nocturnal owls that Renoult et al. (J. Evol. Biol., 2009) study suggested may have flawed our early findings. Thus, the hypothesis that selection has resulted in increased detectability of nestling by adjusting gape coloration to parental visual systems is currently supported by our comparative data.
a Web-Based Platform for Visualizing Spatiotemporal Dynamics of Big Taxi Data
NASA Astrophysics Data System (ADS)
Xiong, H.; Chen, L.; Gui, Z.
2017-09-01
With more and more vehicles equipped with Global Positioning System (GPS), access to large-scale taxi trajectory data has become increasingly easy. Taxis are valuable sensors and information associated with taxi trajectory can provide unprecedented insight into many aspects of city life. But analysing these data presents many challenges. Visualization of taxi data is an efficient way to represent its distributions and structures and reveal hidden patterns in the data. However, Most of the existing visualization systems have some shortcomings. On the one hand, the passenger loading status and speed information cannot be expressed. On the other hand, mono-visualization form limits the information presentation. In view of these problems, this paper designs and implements a visualization system in which we use colour and shape to indicate passenger loading status and speed information and integrate various forms of taxi visualization. The main work as follows: 1. Pre-processing and storing the taxi data into MongoDB database. 2. Visualization of hotspots for taxi pickup points. Through DBSCAN clustering algorithm, we cluster the extracted taxi passenger's pickup locations to produce passenger hotspots. 3. Visualizing the dynamic of taxi moving trajectory using interactive animation. We use a thinning algorithm to reduce the amount of data and design a preloading strategyto load the data smoothly. Colour and shape are used to visualize the taxi trajectory data.
Survey of computer vision technology for UVA navigation
NASA Astrophysics Data System (ADS)
Xie, Bo; Fan, Xiang; Li, Sijian
2017-11-01
Navigation based on computer version technology, which has the characteristics of strong independence, high precision and is not susceptible to electrical interference, has attracted more and more attention in the filed of UAV navigation research. Early navigation project based on computer version technology mainly applied to autonomous ground robot. In recent years, the visual navigation system is widely applied to unmanned machine, deep space detector and underwater robot. That further stimulate the research of integrated navigation algorithm based on computer version technology. In China, with many types of UAV development and two lunar exploration, the three phase of the project started, there has been significant progress in the study of visual navigation. The paper expounds the development of navigation based on computer version technology in the filed of UAV navigation research and draw a conclusion that visual navigation is mainly applied to three aspects as follows.(1) Acquisition of UAV navigation parameters. The parameters, including UAV attitude, position and velocity information could be got according to the relationship between the images from sensors and carrier's attitude, the relationship between instant matching images and the reference images and the relationship between carrier's velocity and characteristics of sequential images.(2) Autonomous obstacle avoidance. There are many ways to achieve obstacle avoidance in UAV navigation. The methods based on computer version technology ,including feature matching, template matching, image frames and so on, are mainly introduced. (3) The target tracking, positioning. Using the obtained images, UAV position is calculated by using optical flow method, MeanShift algorithm, CamShift algorithm, Kalman filtering and particle filter algotithm. The paper expounds three kinds of mainstream visual system. (1) High speed visual system. It uses parallel structure, with which image detection and processing are carried out at high speed. The system is applied to rapid response system. (2) The visual system of distributed network. There are several discrete image data acquisition sensor in different locations, which transmit image data to the node processor to increase the sampling rate. (3) The visual system combined with observer. The system combines image sensors with the external observers to make up for lack of visual equipment. To some degree, these systems overcome lacks of the early visual system, including low frequency, low processing efficiency and strong noise. In the end, the difficulties of navigation based on computer version technology in practical application are briefly discussed. (1) Due to the huge workload of image operation , the real-time performance of the system is poor. (2) Due to the large environmental impact , the anti-interference ability of the system is poor.(3) Due to the ability to work in a particular environment, the system has poor adaptability.
ERIC Educational Resources Information Center
Zhou, Liu; He, Zijiang J.; Ooi, Teng Leng
2013-01-01
Dimly lit targets in the dark are perceived as located about an implicit slanted surface that delineates the visual system's intrinsic bias (Ooi, Wu, & He, 2001). If the intrinsic bias reflects the internal model of visual space--as proposed here--its influence should extend beyond target localization. Our first 2 experiments demonstrated that…
Retinal Information Processing for Minimum Laser Lesion Detection and Cumulative Damage
1992-09-17
TAL3Unaqr~orJ:ccd [] J ,;--Wicic tion --------------... MYRON....... . ................... ... ....... ...........................MYRON L. WOLBARSHT B D ist...possible beneficial visual function of the small retinal image movements. B . Visual System Models Prior models of visual system information processing have...against standard secondary sources whose calibrations can be traced to the National Bureau of Standards. B . Electrophysiological Techniques Extracellular
Fixational Eye Movements in the Earliest Stage of Metazoan Evolution
Bielecki, Jan; Høeg, Jens T.; Garm, Anders
2013-01-01
All known photoreceptor cells adapt to constant light stimuli, fading the retinal image when exposed to an immobile visual scene. Counter strategies are therefore necessary to prevent blindness, and in mammals this is accomplished by fixational eye movements. Cubomedusae occupy a key position for understanding the evolution of complex visual systems and their eyes are assumedly subject to the same adaptive problems as the vertebrate eye, but lack motor control of their visual system. The morphology of the visual system of cubomedusae ensures a constant orientation of the eyes and a clear division of the visual field, but thereby also a constant retinal image when exposed to stationary visual scenes. Here we show that bell contractions used for swimming in the medusae refresh the retinal image in the upper lens eye of Tripedalia cystophora. This strongly suggests that strategies comparable to fixational eye movements have evolved at the earliest metazoan stage to compensate for the intrinsic property of the photoreceptors. Since the timing and amplitude of the rhopalial movements concur with the spatial and temporal resolution of the eye it circumvents the need for post processing in the central nervous system to remove image blur. PMID:23776673
Two different streams form the dorsal visual system: anatomy and functions.
Rizzolatti, Giacomo; Matelli, Massimo
2003-11-01
There are two radically different views on the functional role of the dorsal visual stream. One considers it as a system involved in space perception. The other is of a system that codes visual information for action organization. On the basis of new anatomical data and a reconsideration of previous functional and clinical data, we propose that the dorsal stream and its recipient parietal areas form two distinct functional systems: the dorso-dorsal stream (d-d stream) and the ventro-dorsal stream (v-d stream). The d-d stream is formed by area V6 (main d-d extrastriate visual node) and areas V6A and MIP of the superior parietal lobule. Its major functional role is the control of actions "on line". Its damage leads to optic ataxia. The v-d stream is formed by area MT (main v-d extrastriate visual node) and by the visual areas of the inferior parietal lobule. As the d-d stream, v-d stream is responsible for action organization. It, however, also plays a crucial role in space perception and action understanding. The putative mechanisms linking action and perception in the v-d stream is discussed.
Fixational eye movements in the earliest stage of metazoan evolution.
Bielecki, Jan; Høeg, Jens T; Garm, Anders
2013-01-01
All known photoreceptor cells adapt to constant light stimuli, fading the retinal image when exposed to an immobile visual scene. Counter strategies are therefore necessary to prevent blindness, and in mammals this is accomplished by fixational eye movements. Cubomedusae occupy a key position for understanding the evolution of complex visual systems and their eyes are assumedly subject to the same adaptive problems as the vertebrate eye, but lack motor control of their visual system. The morphology of the visual system of cubomedusae ensures a constant orientation of the eyes and a clear division of the visual field, but thereby also a constant retinal image when exposed to stationary visual scenes. Here we show that bell contractions used for swimming in the medusae refresh the retinal image in the upper lens eye of Tripedalia cystophora. This strongly suggests that strategies comparable to fixational eye movements have evolved at the earliest metazoan stage to compensate for the intrinsic property of the photoreceptors. Since the timing and amplitude of the rhopalial movements concur with the spatial and temporal resolution of the eye it circumvents the need for post processing in the central nervous system to remove image blur.
VIPER: Virtual Intelligent Planetary Exploration Rover
NASA Technical Reports Server (NTRS)
Edwards, Laurence; Flueckiger, Lorenzo; Nguyen, Laurent; Washington, Richard
2001-01-01
Simulation and visualization of rover behavior are critical capabilities for scientists and rover operators to construct, test, and validate plans for commanding a remote rover. The VIPER system links these capabilities. using a high-fidelity virtual-reality (VR) environment. a kinematically accurate simulator, and a flexible plan executive to allow users to simulate and visualize possible execution outcomes of a plan under development. This work is part of a larger vision of a science-centered rover control environment, where a scientist may inspect and explore the environment via VR tools, specify science goals, and visualize the expected and actual behavior of the remote rover. The VIPER system is constructed from three generic systems, linked together via a minimal amount of customization into the integrated system. The complete system points out the power of combining plan execution, simulation, and visualization for envisioning rover behavior; it also demonstrates the utility of developing generic technologies. which can be combined in novel and useful ways.
Jones, P H; Shakdher, S; Singh, P
2017-04-01
Salient findings and interpretations from the canimpact clinical cancer research study are visually represented in two synthesis maps for the purpose of communicating an integrated presentation of the study to clinical cancer researchers and policymakers. Synthesis maps integrate evidence and expertise into a visual narrative for knowledge translation and communication. A clinical system synthesis map represents the current Canadian primary care and cancer practice systems, proposed as a visual knowledge translation from the mixed-methods canimpact study to inform Canadian clinical research, policy, and practice discourses. Two synthesis maps, drawn together from multiple canimpact investigations and sources, were required to articulate critical differences between the clinical system and patient perspectives. The synthesis map of Canada-wide clinical cancer systems illustrates the relationships between primary care and the full cancer continuum. A patient-centred map was developed to represent the cancer (and primary care) journeys as experienced by breast and colorectal cancer patients.
NASA Astrophysics Data System (ADS)
Quinn, J. D.; Larour, E. Y.; Cheng, D. L. C.; Halkides, D. J.
2016-12-01
The Virtual Earth System Laboratory (VESL) is a Web-based tool, under development at the Jet Propulsion Laboratory and UC Irvine, for the visualization of Earth System data and process simulations. It contains features geared toward a range of applications, spanning research and outreach. It offers an intuitive user interface, in which model inputs are changed using sliders and other interactive components. Current capabilities include simulation of polar ice sheet responses to climate forcing, based on NASA's Ice Sheet System Model (ISSM). We believe that the visualization of data is most effective when tailored to the target audience, and that many of the best practices for modern Web design/development can be applied directly to the visualization of data: use of negative space, color schemes, typography, accessibility standards, tooltips, etc cetera. We present our prototype website, and invite input from potential users, including researchers, educators, and students.